Rectangular fire damper TFER 30. pag. C-10

Size: px
Start display at page:

Download "Rectangular fire damper TFER 30. pag. C-10"

Transcription

1 pag. C-10 Description Rectangular fire damper with CE label in conformity to UNI-EN 15650, certified according to EN , classified EI 120 S in accordance to EN Removable shifted kinematic mechanism in order to simplify the installation and to allow the eventual walled substitution. Release thermo-fuse with melting point certified at 70 C (72 C for motorised versions). Manual starting stick. Symmetric construction (blade in the box centre line) with resistance characteristics independent of fire origin direction. Tests Cold smokes passage seal with 300 Pa depression, on minimum and on maximum dimension damper (max. 200 m/h correct to 20 C, for at least 5 minutes). Thermo-isolation with temperature s increase control on box 4 sides in proximity to device, on device in proximity to box and on extraction duct, on maximum dimension damper (max. 180 C for each point, max. 140 C as points average). Hot smokes passage seal with 300 Pa depression, on maximum dimension damper (max. 360 m/h, correct to 20 C). Starting mechanism s solidity with 50 opening/closing cycles and following cold smokes seal test (first point). Thermo-fuse s intervention rapidity, that must release in two minutes from oven s ignition. Servomotor s solidity with functionality test after opening/closing cycles for each of 4 disposable models (see Accessories section). Construction Galvanised sheet-steel box. Calcium silicate (external layers) and calcium sulphate (intermediate layer). Graphite base s thermo-expander. cold smokes seal s silicone gasket. Mineral fibre s thermo gasket. CE label (UNI-EN 15650) The fire damper TFER 30 is in conformity to UNI-EN and is provided of CE label, issued from legally certified institution. Dimensions B (mm) : (increments of 50) H (mm) : (increments of 50) Versions TFER 30 (basic version) : it disposes from thermo-fuse locally directed release (fusion temperature certified at 70 C), manual starting stick and an end-stroke microinterruptor, signaling if the blade is in closing position (two contacts: NA and NC). As option it may have an interruption-current or currentlaunch electromagnet, for remote control s release (alarm control unit) and another end-stroke micro-interruptor (blade in opening position). Both can be easily added, also with already installed damper. TFER 30 M (version disposed for motor) : to be combined with a serie s ATF 2x servomotor, it disposes from thermo-fuse locally directed release, one internal and one external to the box (fusion temperature certified at 72 C), remote control release with current interruption, motorised starting and two end-stroke micro-interruptors, signaling blade s opening and closing position posizion (each one with two contacts: NA and NC). N.B. - The presence of at least one signaling micro-interruptor is recommended in conformity to UNI art To remember that the damper s running must be anyway guaranteed, also without electric current (art. 4.1 UNI 10365). Specifications Rectangular fire damper with CE label in conformity to UNI-EN 15650, certified according to EN , classified EI 120 S in accordance to EN Suitable to installation on rigid vertical wall (also with two coupled units), light vertical wall (plasterboard) and horizontal slab. Removable shifted kinematic mechanism to simplify the installation. Release thermo-fuse calibrated at 70 C. Micro-interruptor notifying closed damper status. Manual starting stick.

2 pag. C Key to symbols 1 - Symmetric box 2 - Mineral-fibre gasket 3 - Graphite thermo-expander gasket 4 - Cold smokes silicone seal gasket 5 - Activation plate gasket 6 - Multilayered refractory blade 7 - Kinematic mechanism link-control 8 - Thermo-fuse release s system 9 - Closing test button 10 - Thermo-fuse 11 - Security block 12 - Heat-sinks

3 pag. C-12 Installation N.B. A damper s fire resistance depends on device characteristics, that is the damper has not an own class resistance, but it s always depending on considered device. 1 - Rigid vertical wall N.B. Installation s operations (device s perforation, damper s positioning and filling) are completely described in the installation manual. N.B. The minimum distance between two fire dampers installed on two different ducts cannot be less than 200 mm. N.B. The minimum distance between the fire damper and structural elements around (ceiling, floor, walls) cannot be less than 75 mm. N.B. The 4 following installaton typology are allowed, corresponding to the tests conditions employed from certified laboratory. For each one, classification report allows the fire damper s employment in accordance to law, in the same conditions. 1 Rigid vertical wall Wall class REI 120 Wall thickness 100 mm Wall density 500 kg/m 3 Maximum duct dimensions (BxH) 1500x800 mm Damper class EI 120 S (300 Pa) ve i o 2 Rigid vertical wall - 2 vertical units (flange against flange) Wall class REI 120 Wall thickness 100 mm Wall density 500 kg/m 3 Maximum duct dimensions (BxH) 1500x1600 mm Damper class EI 120 S (300 Pa) ve i o 3 Lightweight insulated vertical wall (plasterboard + steel-wool + plasterboard) Wall class REI 120 Wall thickness 100 mm ( mm) Wall density 100 kg/m 3 (steel-wool) Maximum duct dimensions (BxH) 1500x800 mm Damper class EI 120 S (300 Pa) ve i o 4 Horizontal slab Slab class REI 120 Slab thickness 150 mm Slab density 2200 kg/m 3 Maximum duct dimensions (BxH) 1500x800 mm Damper class EI 120 S (300 Pa) ho i o N.B. - As described in the installation manual, the air spaces resulting between the damper and its device must be filled with M10 or upper class mortar (EN 998-2).

4 pag. C Rigid vertical wall - 2 vertical units 3 - Lightweight insulated vertical wall Steel-wool lines Plates ATF 35 Plates ATF 35 N.B. - In case of flange against flange dampers (case 2) the couple must be executed through special plates ATF 35 (see Accessories section ) filling the gap between the two units with 100 kg/m 3 steel-wool lines (see Installation manual). N.B. - This installation typology is the most complicated one and requests to pay more attention : FCR disposes of an alternative solution called TFERS 30, that is a rectangular fire damper that keeps the same characteristics of TFER 30 but purposely conceived for fast assembly on plasterboard.

5 pag. C Horizontal slab Accessories ATF Vdc (normally energised) interruptionelectromagnet. ATF Vac (normally energised) interruptionelectromagnet. ATF Vdc (normally de-energised) launch electromagnet. ATF Vac (normally de-energised) launch electromagnet. ATF 15 Open position blade s signaling micro-interruptor (contact NA/NC). ATF Vdc servomotor - BxH < 0,8 m 2. ATF Vdc servomotor - BxH 0,8 m 2. ATF Vac servomotor - BxH < 0,8 m 2. ATF Vac servomotor - BxH 0,8 m 2. ATF 31 Hatch 140 mm with gasket. Position: upper (kinematic mechanism side). ATF 32 Hatch 140 mm with gasket. Position : opposite side to kinematic mechanism. ATF 33 Hatch 140 mm with gasket. Position : lower (kinematic mechanism side). ATF 34 Fixing brackets (4) for assembly on plasterboard. ATF 35 Plates (4) for dampers coupling (flange against flange).

6 pag. C-15 Aeration and hearing characteristics Correction factors DP for B 400 mm. P (Pa) B=400 mm 30 H= v (m/s) db A B (mm) DP/DP B400 B (mm) DP/DP B , , , , , , , , , , , , , , , , , , , , , , , , , , ,7 Key to symbols v DP L WA Speed = Capacity/gross section BxH (m/s) Open damper pressure drop (Pa) Pressure sound level weighted A (db A - rif W) v L WA - spectral correction - (db A ) (m/s) K 2K 4K 8K Add algebrically to value L WA resulting on diagram (correcting if B 400 mm.), in order to obtain sound power spectrum. Correction factors L WA for B 400 mm. B (mm) DL WA (db A ) B (mm) DL WA (db A ) 200 3, , , , , , , , , , , , , , , , , , , , , , , , , , ,8 Example Consider a rectangular duct with dimensions BxH = 800x400 mm, which crosses a rigid wall REI 120, through a fire damper TFER 30. The capacity in the duct is supposed to be 5000 m 3 /h. It would results : v = 5000 / (3600 * 0,8 * 0,4) = 4,3 m/s DP = 0,7 * Pa L WA = 1, db A

7 pag. C-16

7/S5 FIRE DAMPER FD40. v 2.9 (en)

7/S5 FIRE DAMPER FD40. v 2.9 (en) 7/S v.9 (en) FIRE DAMPER FD0 www.klimaoprema.hr 69 FIRE DAMPER - FDC TABLE OF CONTENTS FIRE DAMPER FD0 7 FIRE CLASSIFICATION 7 SELECTION DIAGRAM 7 ORDERING KEY 7 DAMPER MODELS 7 FD0-M rectangular fire

More information

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

7/S1 FIRE DAMPER PPZEN. v 2.5 (en) 7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...

More information

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

7/S6 FIRE DAMPER FDC40. v 2.9 (en) 7/S6 v.9 (en) FIRE DAMPER FDC0 www.klimaoprema.hr 8 TABLE OF CONTENTS FIRE DAMPER FDC0 87 FIRE CLASSIFICATION 87 SELECTION DIAGRAM 88 ORDERING KEY 88 DAMPER MODELS 89 FDC0-M cylindrical fire damper with

More information

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings

More information

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages

More information

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm. Fire damper pl-30 General characteristics Application Fire dampers prevent fire and smoke from spreading through ventilation ducts in buildings. The dampers are intended for use inside buildings and are

More information

PKI-C Cartridge Fire Dampers

PKI-C Cartridge Fire Dampers Fire Safety Products / 7 PKI-C Cartridge Fire Dampers Fire resistance class EI60S, EI90S and EI0S 96 - CPD - 000 Ordering codes Fire resistance class PKI-C-EI - 60S, 90S and 0S Codes section. The thermal

More information

Systemair Fire Dampers

Systemair Fire Dampers Fire safety products 1 / 7 Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S 1396 - CPD - 0061 1396 - CPD - 0062 Ordering codes Ordering Codes for Circular FD: Fire resistance class

More information

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB Valid from //06 EN 5650:00-09 FIRE DAMPER FDMB These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMB. It is valid for production, designing,

More information

M A D E L. FOK-EIS-180 Fire dampers CE

M A D E L. FOK-EIS-180 Fire dampers CE M A D E L EN 60: FOK-EIS-80 Fire dampers CE The fire dampers FOK-EIS-80 work as a separator between two sectors of fire and ensure the same fire resistance that the structural elements of compartmentalisation,

More information

PKIR3G, PKIS, PKIS3G and PKIS3GA

PKIR3G, PKIS, PKIS3G and PKIS3GA PKIR3G, PKIS, PKIS3G and PKIS3GA Fire Dampers Fire resistance EI60S, EI90S and EI120S 1396 - CPR - 0076 1396 - CPR - 0077 1396 - CPD - 0062 Ordering codes Dimensions Type of activation PKIR3G 1) - ødn

More information

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD TPM 075/09-DK VALID FROM: 15/1/2012 I. CONTENT These technical specifications state a row of manufactured sizes and models of fire dampers and fire dampers

More information

Fire damper FK120/FK90 TECHNICAL DATA

Fire damper FK120/FK90 TECHNICAL DATA Fire damper FK120/FK90 TECHNICAL DATA 2 Fire damper FK120/FK90 Figure 1 ER1 Figure 2 ER3 The rectangular fire damper FK120/FK90 is available both as motorized and with fuse. The damper casing is manufactured

More information

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR MANAGEMENT FIRE DAMPERS ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE 2 ETPR-E-1 Fire damper Technical catalogue Fire and smoke damper ETPR-E-1 is used as a closing device for preventing the

More information

Fire/smoke damper EKO-JBG2

Fire/smoke damper EKO-JBG2 Fire/smoke damper EKO-JBG2 Description The EKO-JBG2 fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.

More information

Systemair Fire Dampers

Systemair Fire Dampers Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S www.systemair.com As standard, all fire dampers are designed and certified to comply with EI-S performance attributes. fire dampers

More information

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Fire Dampers. Types FKA FRL FRK 4/1/EN/1 Fire Dampers Types FKA FRL FRK /1/EN/1 Contents Description Description... Construction... Standard Sizes Installation Details... Functional Description Product Range... Accessories... Circuit Diagrams...

More information

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8. Fire safety products 1 / 8 DKISMA Systemair multicompartment rectangular smoke control dampers Resistance class EI120(v ew i o) S1500C mod AAmulti 1396 - CPR - 0112 Ordering codes Nominal dimensions Type

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

Fire/combustion gas damper EKO-JBL

Fire/combustion gas damper EKO-JBL Fire/combustion Description The fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting. The damper is designed

More information

Fire/smoke damper EKO-SRBG1

Fire/smoke damper EKO-SRBG1 Fire/smoke damper EKO- Description The EKO- fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.

More information

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of

More information

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

Fire damper ETPR. Specifications. Product code example Fire damper ETPR Fire damper ETPR ETPR fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 1366-2. ETPR meets the requirements of fire class EI 60 S / EI 90 S.

More information

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA 96 - CPR - 0 ORIGINAL INSTALLATION, MAINTENANCE AND OPERATION MANUAL EVERY SMOKE DAMPER NEEDS TO BE INSTALLED IN ACCORDANCE WITH THIS MANUAL! / PP-5_0604 DKISMA

More information

ESAS Smoke control damper

ESAS Smoke control damper ESAS Smoke control damper 1 Rectangular smoke control damper ESAS is specially designed to use in single fire compartment applications as a closing or as an opening damper for smoke extract purposes. ESAS

More information

Smoke damper EKO-SRB1

Smoke damper EKO-SRB1 Smoke damper EKO-SRB1 Description The EKO-SRB1 smoke damper is a CE-approved damper in fire class E60 intended for fire compartmentation or protection against the spread of fire and smoke in ventilation

More information

Fire/combustion gas damper EKO-JBG

Fire/combustion gas damper EKO-JBG Fire/combustion EKO-JBG Description The EKO-JBG fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting.

More information

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN Fire damper BKA-EN with general technical approval Z-41.3-667 tested according to DIN EN 1366-2 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Phone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980

More information

VARYCONTROL VAV Dual Duct Terminal Boxes

VARYCONTROL VAV Dual Duct Terminal Boxes 5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk

More information

Combustion gas damper EKO-JB

Combustion gas damper EKO-JB EKO-JB Description The EKO-JB combustion is a Class E6 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment wall or floor

More information

CONSTANTFLOW Volume Flow Controllers

CONSTANTFLOW Volume Flow Controllers 5/9.1/EN/8 CONSTANTFLOW Volume Flow Controllers for constant volume systems Type EN The art of handling air Contents Description Description 2 Application 3 Construction Dimensions Accessories 4 Dimensions

More information

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance 07/2013 Fläkt Woods FIFLO EN 2013.07 2 ZU CLOSED AUF OPEN Fire damper ETPS-EI Contents Operation and Maintenance

More information

VU120. Rectangular smoke evacuation damper. V22-EN-G 08/2017

VU120. Rectangular smoke evacuation damper.  V22-EN-G 08/2017 Organisme Certificateur AFNOR Certification - www.marque-nf.com VU120 Rectangular smoke evacuation damper. en 0749 Clapets coupe-feu et Volets de désenfumage D.A.S. Rf-Technologies nv Lange Ambachtstraat

More information

Technical information

Technical information 6-8 Application Rectangular NK and NL types are pressure-independent VAV and CAV air volume control terminals. The terminals are designed particularly for systems with large air volumes and duct sizes

More information

VU120. Rectangular smoke evacuation damper. V22-F 07/2015

VU120. Rectangular smoke evacuation damper.   V22-F 07/2015 Organisme Certificateur AFNOR Certification - www.marque-nf.com VU120 Rectangular smoke evacuation damper. en Clapets coupe-feu et Volets de désenfumage D.A.S. Rf-Technologies nv Lange Ambachtstraat 40

More information

Heights up to 1000 mm Fire resistance period up to 120 minutes

Heights up to 1000 mm Fire resistance period up to 120 minutes Maintenance-free FK90 fire dampers - series FK120 - Heights up to 1000 mm Fire resistance period up to 120 minutes Fire classification: EI 30/60/90/120 (ve - ho, i o) S C10ooo Hygiene certificate Environmental

More information

ROOF FAN ROOFMASTER STEC

ROOF FAN ROOFMASTER STEC AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...

More information

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N V1175 FD-C Series Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper ES classified fire dampers with reduced smoke leakage characteristics (BS E 1366-2) Aerodynamically

More information

Slot diffusers for ceiling installation

Slot diffusers for ceiling installation X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger

More information

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION air handling intelligence FIRE SFETY Fire Damper in libraries of EI 10 (v e -i o) S EN 13501-3+1:01 EN 15650:0 Certificate of Conformity 1488-CPD-081/W EUROPEN PTENT PPLICTION EP 01158318 GOLD MEDL MTP

More information

CU2. Wide-ranging rectangular fire damper up to C2-G 08/2015

CU2. Wide-ranging rectangular fire damper up to C2-G 08/2015 Organisme Certificateur AFNOR Certification - www.marque-nf.com CU2 Wide-ranging rectangular fire damper up to 120 en Clapets coupe-feu et Volets de désenfumage D.A.S. Rf-Technologies nv Lange Ambachtstraat

More information

TYPE EK-EU SMOKE CONTROL DAMPER

TYPE EK-EU SMOKE CONTROL DAMPER Homepage > PRODUCTS > Fire and Smoke Protection > Smoke Control Damper > Type EK-EU TYPE EK-EU SMOKE CONTROL DAMPER WITH TROXNETCOM AS AN OPTION CE COMPLIANT ACCORDING TO EUROPEAN REGULATIONS EK-EU WITH

More information

A B. Linear cylinder diffuser LC. pag. A-52

A B. Linear cylinder diffuser LC. pag. A-52 pag. A-5 Linear cylinder diffuser LC Description Linear rotating cylinder diffuser for ceiling or wall installation. Each slot houses inside a range of cylinders, that, by rotation, allow differents launch

More information

FK120/FK90 FIRE DAMPER» INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE

FK120/FK90 FIRE DAMPER» INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE FIRE SAFETY AIR ANAGEENT FIRE DAPERS FK120/FK90 FIRE DAPER» INSTRUCTIONS FOR INSTALLATION, OPERATION AND AINTENANCE ZU CLOSED AUF OPEN 2 FK120/FK90 Fire damper Instructions for installation, operation

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request) HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to

More information

Combustion gas damper EKO-SRB

Combustion gas damper EKO-SRB Combustion EKO-SRB Description The EKO-SRB combustion is a Class E60 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment

More information

Fire dampers ETCE and ETCS TECHNICAL DATA

Fire dampers ETCE and ETCS TECHNICAL DATA Fire dampers ETCE and ETCS TECHNICAL DATA 2 Fire dampers ETCE and ETCS Veloduct ETCE fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 13662.

More information

series CEVH Smoke Evacuation Damper

series CEVH Smoke Evacuation Damper series CEVH Smoke Evacuation Damper www.koolair.com Series CEVH 1 CONTENTS Description 2 Dimensions 4 Installation 5 Assembly 6 Electrical connections 7 Technical data 8 Coding 10 2 Series CEVH Description

More information

series FSD-FLD Fire and smoke dampers UL Approval

series FSD-FLD Fire and smoke dampers UL Approval series FSD-FLD Fire and smoke dampers UL Approval www.koolair.com Series FSD-FLD 1 Fire and smoke dampers UL Approval FSD-B-U / FSD-A-U and FLD-S-U / FLD-S-UD CONTENTS Description FSD-B-U / FSD-A-U 2 Construction

More information

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3 SA/6/1/EN/3 Fire Dampers Type FDF Compliant to SABS (193:2004) TROX (South Africa) (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax. +27 (0)33 398 1100 email : pmb@troxsa.co.za

More information

CR120. Optimized circular fire damper up to 120' C11-I 07/2015

CR120. Optimized circular fire damper up to 120'   C11-I 07/2015 Organisme Certificateur AFNOR Certification - www.marque-nf.com CR120 Optimized circular fire damper up to 120' en Clapets coupe-feu et Volets de désenfumage D.A.S. Rf-Technologies nv Lange Ambachtstraat

More information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular

More information

Bevent Rasch BSK Fire /04/2017

Bevent Rasch BSK Fire /04/2017 Bevent Rasch - Fire - BSK120 10/04/2017 Rectangular Fire resistance class /S Sizes from 200 x 200 mm to 1200 x 1000 mm Prefitted safety actuator 24V or 230V Available in MagiCAD CE-marked building product

More information

CR2. Circular fire damper C1-C 04/2010

CR2. Circular fire damper C1-C 04/2010 Rf-Technologies nv - Lange Ambachtstraat 40-9860 Oosterzele - België - Tel +32 9 362 31 71 - Fax +32 9 362 33 07 - www.rft.be - info@rft.be Table of contents o n t e n t s Pr o d u c t p r e s e n tat

More information

CRE60 XF9499. Røgevakueringsspjæld Ø100-Ø630. AiR Ξ FORCE CRE60 XF9499 FORCE:

CRE60 XF9499. Røgevakueringsspjæld Ø100-Ø630. AiR Ξ FORCE CRE60 XF9499 FORCE: AiR Ξ FORCE CRE60 XF9499 Røgevakueringsspjæld Ø100-Ø60 CRE60 XF9499 FORCE: Røgevakueringsspjæld Ø100-Ø60 Super let montage Godkendt for montage væk fra væg Monteres i både tunge og lette vægge/dæk Lavt

More information

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS INSTALLATION, MOUNTING AND OPERATING BSK-EN Fire damper Contents Description... 2 Models and dimensions... 3 Mounting information... 5 Installation information... 6 Technical data... 7 Accessories... 9

More information

CU-LT. Optimised rectangular fire damper up to C3-EN-J-06/2018

CU-LT. Optimised rectangular fire damper up to C3-EN-J-06/2018 CU-LT Optimised rectangular fire damper up to 120 en 0749 Rf-Technologies nv Lange Ambachtstraat 40 9860 Oosterzele Belgium Tel +32 9 362 31 71 Fax +32 9 362 33 07 info@rft.be www.rft.be C3-EN-J-06/2018

More information

Type VSD35. Nominal length up to 1500 mm: one spigot

Type VSD35. Nominal length up to 1500 mm: one spigot Type VSD35 Nominal length up to 1500 mm: one spigot NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with 35 mm diffuser face (nominal width) and adjustable air control elements

More information

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects March 06 A-60 Marine Fire Dampers Tests and Approvals A60 Fire Rated. Lloyds Register of Shipping Approved. Marine Equipment Directive compliant. USCG Approved. Germanischer Lloyds Approved. American Bureau

More information

Bevent Rasch BSK6. - Fire /04/2017

Bevent Rasch BSK6. - Fire /04/2017 Bevent Rasch - Fire - BSK6 11/04/2017 Fire resistance class EI60 / EI60S Sizes from 200 x 200 mm to 800 x 800 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product

More information

Fire Safety Products. Product Overview

Fire Safety Products. Product Overview Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Fire Safety Products Product Overview SAFETY PRODUCTS prevent the spread of

More information

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1 Shutter Fire Damper Type FSD GFSD /./B/ Contents Description Description... Construction... Installation Details... Control Accessories... Technical Data... Order Details... 7 8 9 FSD-L GFSD-L FSD Fire

More information

CU2-15. Rectangular fire damper 120' at 1500 Pa. C7-EN-I 06/2018

CU2-15. Rectangular fire damper 120' at 1500 Pa.   C7-EN-I 06/2018 CU2-15 Rectangular fire damper 120' at 1500 Pa en 0749 Rf-Technologies nv Lange Ambachtstraat 40 9860 Oosterzele Belgium Tel +32 9 362 31 71 Fax +32 9 362 33 07 info@rft.be www.rft.be C7-EN-I 06/2018 2

More information

Fire Damper BSK-RPR. with general building supervisory approval Z

Fire Damper BSK-RPR. with general building supervisory approval Z Fire Damper BSK-RPR with general building supervisory approval Z-41.3-681 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

series Silencers

series Silencers series SK Silencers www.koolair.com Series SK 1 Silencers CONTENTS ASK-1 and ASK-2 Round Silencers Description 4 ASK-1 Overall Dimensions 5 ASK-2 Overall Dimensions 6 Selection Table and Weights 7 ASK-1

More information

CU2/B. Battery assembly of max. 4 individual dampers. C31-EN-G 06/2018

CU2/B. Battery assembly of max. 4 individual dampers.   C31-EN-G 06/2018 CU2/B Battery assembly of max. 4 individual dampers en 0749 Rf-Technologies nv Lange Ambachtstraat 40 9860 Oosterzele Belgium Tel +32 9 362 31 71 Fax +32 9 362 33 07 info@rft.be www.rft.be C31-EN-G 06/2018

More information

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

Technical documentation

Technical documentation VM-PRO Mechanical volumetric flow control- Table of Contents Areas of application... 2 Useable volumetric flow ranges... 2 Function... 3 Processing... 3 Available sizes / -dimensions... 4 Accessories list

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

Smoke control damper RKI-90 Test certificate Z

Smoke control damper RKI-90 Test certificate Z Resistance class EK90 within smoke extraction ducts that have a fire resistance time of 90 min Ordering example / dimensions smoke control damper consisting of the housing with cut-off damper designed

More information

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL... 1/11 29/06/2016 VENTILATION AND Buildings & Technical Services Section AIR-CONDITIONING STANDARD CONTENTS 1. GENERAL... 2 2. DUCTS, AIR VENTS, VALVES... 2 3. MONOBLOCK UNITS... 3 4. FILTRATION... 5 5.

More information

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers. TransShield Mode 1/2 Transfer Stainless Steel Sliding Plate Fire Dampers www.actionair.co.uk sales@actionair.co.uk Introduction The TransShield Modes 1 and 2 stainless steels stainless steel sliding plate

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description DCV-CF Pressure controlwith airflow measuring 24VAC + Communication Pressure control with airflow measuring DCV-CF DIN 24VAC + Communication AIN AOUT SMART DAMPERS & MEASURING UNITS PRESSURE & FLOW DCV-CF

More information

CYCLONE F 400 smoke extraction casing

CYCLONE F 400 smoke extraction casing Fire protection CYCLONE F smoke extraction casing Presentation of the CYCLONE F range (12) WHY CHOOSE A CYCLONE F? In order to fulfil the requirements of the CE markings (EN 1211-3 and the French governmental

More information

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas. Systemair Fire Dampers for Explosive Areas Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S www.systemair.com Description Fire damper (hereafter referred to as damper) is a fire

More information

Pressure control damper ERPA

Pressure control damper ERPA Key features Constant pressure Real-time pressure monitoring with FW compact controller Can be connected to Modbus Available in IPSUM compatible version ERPA is a rectangular pressure control damper for

More information

Motorized Fire Dampers

Motorized Fire Dampers Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and

More information

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/ 6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille Halton WDD/WSD Universal Grille Horizontal air supply, suitable also for exhaust Adjustable vertical front vanes, adjustable horizontal rear vanes: WDD, adjustable horizontal vanes: WSD Aluminium construction

More information

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX DAMPERS LSS - R LSS / SOD circular single blade shut off damper SSVent rectangular multiblade shut off damper S.Ventil R1OVL circular single blade weather tight damper/valve RD circular regulating damper

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:

More information

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face 2/1/EN/3 Slot Diffuser Type VSD15 with 15 mm wide diffuser face Contents Air Diffuser Discharge Characteristics (horizontal) 2 Description 3 Air Diffuser Discharge Characteristics (alternating) 3 Construction

More information

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE Homepage > Products > Sound attenuators > Splitter sound attenuators > Type MSA Type MSA Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

More information

SEMI RIGID THE PROFESSIONALS CHOICE

SEMI RIGID THE PROFESSIONALS CHOICE SEMI RIGID THE PROFESSIONALS CHOICE for efficient, high performance MVHR ductwork installations. SAP APPENDIX Q LISTED brookvent.co.uk FITTING OUTLINE THE PROFESSIONALS CHOICE for efficient, high performance

More information

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

WAY MOTORISED COMPACT ZONE VALVES

WAY MOTORISED COMPACT ZONE VALVES 2-3 - 4 WAY MOTORISED COMPACT ZONE VALVES CT0736.0_03 EN May 2015 ZONE 2C ZONE 4C ZONE 3C o o o Reduced overall dimensions; Extremely quiet operation; Valve with union connections. PRODUCTION RANGE Valve

More information

Multileaf damper with actuator

Multileaf damper with actuator JZ Multileaf damper with actuator FOR SHUTTING OFF THE AIRFLOW IN AIR CONDITIONING SYSTEMS Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings

More information

BRC

BRC ------------------------------------------------------------- Enclosed climate beam for cooling, heating and ventilation CLIMATE BEAM is an enclosed climate beam with integrated circulation air openings

More information

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181 Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:

More information

Rectangular smoke damper (remote controlled)

Rectangular smoke damper (remote controlled) Clapets coupe-feu et Volets de désenfumage D.A.S. Organisme Certificateur AFNOR Certification - www.marque-nf.com VU10 Rectangular smoke damper (remote controlled) Rf-Technologies nv - Lange Ambachtstraat

More information

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise Halton AWE/AWU Universal Grille Horizontal air supply, suitable also for exhaust Fixed front vanes, stable throw pattern with vertical 15 deflection: AWE, no deflection: AWU Adjustable rear vanes for horizontal

More information

HIGH-POWERED VENTILATORS

HIGH-POWERED VENTILATORS HIGH-POWERED VENTILATORS WITH ROOF FANS 400ºC/2h The THT/HATCH series was designed using high-powered ventilator technology for smoke extraction in the event of a fire, and is equipped with THT series

More information