- Views:
Transcription
1
2 6-8
3
4 Application Rectangular NK and NL types are pressure-independent VAV and CAV air volume control terminals. The terminals are designed particularly for systems with large air volumes and duct sizes and for the accurate measurement and control of air volumes using the patented airflow sensor type Flo- Cross airflow sensor. In CAV application, the terminals maintain the required constant airflow independent of the inlet static pressure. In VAV application, the terminals control the air volume to the room, to match the cooling load required thus saving energy consumption in both cooling and heating applications. The VAV or CAV terminals can be used either for supply or return air applications in new or refurbishment projects. The terminals have single wall (type NK) or double wall (type NL) construction and can be optionally supplied with an additional sound attenuator or a hot water or electric reheater. Features: Pressure independent control functions. Compact design. Volume control range 100% to 10%. Low pressure loss over the terminal. Single or double wall construction. Factory fitted additional attenuator and/or built-in hot water or electric reheater. Multi-leaf damper blade with full shut-off option. Low noise production. Suitable for large air volumes. Suitable for all control functions VAV, CAV, shut-off to maximise system energy savings. Flo-Cross, 2 x 12 points averaging and signal amplifying airflow sensor, better than 2.5% accuracy even with irregular duct approach. Maintenance free. Technical information Casing: Single or double wall, air-tight construction made of galvanized sheet steel with low casing leakage rate. Insulation: In case of double wall construction 25mm insulation material is completely enclosed by the double wall construction. Damper: Damper blade: aluminium, aerofoil 50mm wide opposed blade construction with external linkage. Blades can be optionally provided with neoprene gasket for full shutoff function. Flo-Cross: Extruded aluminium construction with nylon core and feet. Sound attenuator: Constructed from galvanized sheet steel, internal acoustic insulation, erosion proof up to 30m/s. Reheaters: Choice of electric reheat coil VAC/1-phase or VAC/3-phase or hot water reheat coil. Controls: Suitable for use with pneumatic, analogue, electronic or DDC controllers. Controls can be factory fitted, wired and calibrated. A controls enclosure made from galvanised sheet steel can be provided as an option. Delivery format: Delivery format: The VAV or CAV terminal will be supplied as a single assembly. Optional ordered distribution plenum, reheat coil and/or controls are factory fitted, wired and calibrated. The on site delivered terminal is ready to be installed and commissioned. Controls location and hot water or electric connections are fitted on the right hand side of the terminal when looking in the direction of the airflow. On request, the terminal can be delivered with connections on the left hand side. When terminals are ordered with controls, these will be factory fitted, wired and calibrated upon request.
5 Specify as: Example: Supply and install rectangular variable air volume terminals with double-wall construction, constructed from galvanized sheet steel. The casing leakage rate shall be classified according to class II, VDI3803/DIN24194 and the duct connections shall be 30 mm flange type. The VAV terminals shall have a multi-leaf opposed blade dampers. A Flo-Cross centre averaging airflow sensor with at least 2 x 12 test points and amplified signal shall control the airflow with an accuracy of not less than 2.5%. The controller shall be I/A Series DDC controller: LON compatible, type MNL-V2RVx. Controls must be factory fitted, wired and calibrated according to the following requirements: Maximum air volume 1280 l/s Minimum air volume 512 l/s Terminal size 400 x 400 mm Max. pressure loss 38 Pa Max. discharge sound index < Δp Max. radiated sound index < Δp Ordering example: type - model - handing= NLODOOB Manufacturer: Barcol-Air Installation Instructions: The Barcol-Air VAV terminals shall be installed using at least two support brackets, with antivibration rubber under the terminal as shown in the drawing below. Each of these brackets shall be fixed with two threaded rods to the ceiling slab above. The installation method shall: 1.Prevent the body of the VAV terminal from high mechanical tension, which could damage the construction and performance of the terminal. 2.Prevent torsion on the VAV terminals, which could cause malfunction of the damper blades. 3.Provide some flexibility to the final location of the VAV terminals. 4.Use at least one diameter straight duct length before the VAV inlet. 5.Additional manual volume control dampers(vcd's)shall not be used before the unit inlet should not be used. 6.All connections shall be thermally isolated. 7.The Flo-Cross airflow sensor pressure sensing tubes shall not be "kinked" or otherwise obstructed by the external duct insulation. See drawing below. optional:4 x duct fixing hook contact Barcol-Air for futher details
6 Notes 1.All dimensions in mm. 2.All flanges are 30mm wide. 3.Other dimensions are available on request.
7 Notes 1.All dimensions in mm. 2.All flanges are 30mm wide. 3.Other dimensions are available on request.
8 Model Model
9 Model Model
10 Model Model
11
NV series. Induction VAV air volume control terminals
NV series Induction VAV Description Table of contents Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 Model overview / dimensions 4-5 Sound data NVOAOOB...
More informationCircular VAV and CAV air volume control terminals
NA / NB series Circular VAV and CAV Table of contents Description Page Type designation 1 Technical data - General - Specification - Installation instruction Model overview / dimensios - NBOA... / NBOB...
More informationNR series. Circular CAV air volume control terminals with system powered mechanical regulator
series Circular CAV air volume control terminals Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 overview / dimensions 4-5
More informationSINGLE DUCT TERMINAL UNITS
www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product
More informationVAV TERMINAL BOXES TYPE: BA BT
Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500
More informationSINGLE DUCT AIR TERMINAL UNITS
AIR terminal units AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units are at the core of
More informationVariable Air Volume Dampers
OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control
More informationVariable Air Volume (VAV) Pressure Independent Control
VAV Terminal Units Asli Variable Air Volume (Vav) Terminal Units are volume flow rate controller for supply air on variable air volume system. These units are designed to control the airflow rate of conditioned
More informationVAV Terminal Units SDS
VAV Terminal Units SDS VAV Terminal Units SDS STEKON SDS; controls the volume of conditioned air into an occupied space in response to a thermostat or Building Management System control signal with minimal
More informationHeat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en
X X testregistrierung Heat exchanger Type For the reheating of airflows in circular ducting Circular hot water heat exchanger for the reheating of airflows, suitable for VAV terminal units Type TVR and
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More informationFan - Powered Terminal Unit Series Flow
5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone
More informationPH SERIES SINGLE DUCT ATU PERFORMANCE DATA
PH SERIES SINGLE DUCT ATU PERFORMAE DATA The Performance Aire PH Series is the simplest and most widely used VAV terminal unit. Its basic components are an insulated sheet metal box, round inlet damper,
More informationI Fan Powered Terminal Unit
I Fan Powered Terminal Unit VARIABLE VOLUME PARALLEL FLOW Fan Powered Terminal Unit Variable volume parallel flow Product Overview Variable Volume/Parallel Flow Fan Powered Terminal Units Honeywell parallel
More informationSINGLE DUCT AIR TERMINAL UNITS
SINGLE DUCT AIR terminal units SINGLE DUCT AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units
More informationRETROFIT TERMINAL UNITS
GENERAL PROUCT OVERVIEW Retrofit Terminal s Convert Constant Air Volume Systems to Variable Air Volume. Convert Constant Volume ual uct Systems to Variable Air Volume. Convert Multizone Systems to Variable
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1
X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationType TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF
Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Rectangular VAV terminal units for standard applications regarding the supply air or extract air control in variable air volume
More informationCAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1
X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air
More informationSTR Circular VAV Terminal Units
STR Circular VAV ASLI Circular Variable Air Volume (STR) Terminal s are volume flow rate controller for supply air on variable air volume system. These units are designed to control the airflow rate of
More informationVAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD
VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD R CONTENTS MODEL: KYODO / KYODO-R... 1 INTRODUCTION... 1 APPLICATION... 1 VARIABLE AIR VOLUME SYSTEM... 1 FEATURES... 2 MATERIALS... 3 AIR VOLUME CONTROL
More informationATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.
ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.
More informationSECTION AIR TERMINAL UNITS
SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More information500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)
500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5
More informationVARYCONTROL VAV Dual Duct Terminal Boxes
5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk
More informationJVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6
1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators
More informationIAQ. Model AVC. SINGLE DUCT VAV Model AVC
NON FAN POWERED UNITS SINGLE DUCT VAV Model AVC Model AVC The Carnes Model AVC is available as a basic control unit with open end discharge, with an optional multi-discharge adapter module, or sound attenuator
More informationProduct Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm
Product Data 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems 40 to 3700 cfm The 35J retrofit terminal units offer: Unit casing of 22-gage galvanized steel construction (optional
More informationCAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1
X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air
More informationCAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)
X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered
More informationCatalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI
Air Terminal Units Models MQTH, MQFCI and MQFVI Catalog 903-1 Model MQTH Model MQFCI Model MQFVI Table of Contents Single Duct Air Terminal Units.... 3 Introduction....3 MQTH-500 Single Duct Air Terminal
More informationType TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES
Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting K
.1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERAL UNITS Constant Volume (Series Flow), Standard Design Models ACF w/o Coil ACW w/hot Water Coil ACE w/electric Coil The Carnes constant volume fan terminal unit provides constant air volume to
More informationMOTORIZED VOLUME DAMPER
MOTORIZED VOLUME DAMPER 1 a perfect partner in performance... Our Product Ranges Dampers 1 Fire Dampers 2 Fire / Smoke Dampers 3 Volume Control Dampers 4 Motorized Control Dampers 5 Pressure Relief Dampers
More informationFAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES
FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing
More informationSINGLE DUCT TERMINAL UNITS 30X/HQX SERIES
30X/HQX SERIES 30X SERIES EXHUST 30HQX SERIES EXHUST HOSPITL GRDE QUIET TYPE WITH DISSIPTIVE SILENCER PRODUCT OVERVIEW Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an
More informationIAQ. ROUND DUCT RETROFIT Model ARR
Non Fan Powered Units ROUND DUCT RETROFIT Model ARR IAQ External Insulation Standard The Carnes Model ARR offers low pressure drop, low sound levels, and valve characteristics which create stable control
More informationControl units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL
Control units Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL The art of handling air Ventilation and air conditioning systems must fulfil complex and demanding requirements. With
More informationVAV terminal units. Type TVM. For dual duct systems PD TVM 1
X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings
More information(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4
HAR Variable Air Volume Diffusers Contents: (click on page links below) General & Performance Data 1 Suggested Spec 3 Accessories 4 AUCKLAND ph 09 279 5250 fax 09 275 5637 sales@temperzone.co.nz WELLINGTON
More informationParts and characteristics
Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly
More informationseries RVV Variable flow rate controllers
series RVV Variable flow rate controllers www.koolair.com Series RVV 1 CONTENTS Variable flow rate controllers, type RVV Description 2 Dimensions and product code 3 Selection tables 4 Variable flow rate
More informationCAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1
X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered
More informationIAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW
SINGLE DUCT w/hot WATER HEAT Model AVW Model AVW The Carnes Model AVW is available as a basic control unit with hot water reheat and open end discharge, with an optional sound attenuator module, and optional
More informationTSS Single-Duct VAV Terminals
TSS Single-Duct VAV Terminals Model TSS construction features Standard Construction Mechanical-lock construction ensures lowest possible casing leakage Roll-formed inlet collar with integral stiffening
More informationType TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES
Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume
More informationFor installation into ductwork
X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum
More informationVAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1
X X testregistrierung VAV terminal units Type Easy controller Compact controller Rectangular connection on the room end Circular connection on the fan end For supply air systems with demanding acoustic
More informationVAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING
VAV/CAV BOXES COMMERCIAL BUILDINGS A guide to VAV/CAV, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk At Price TWA we believe
More informationCONSTANTFLOW Volume Flow Controllers
5/9.1/EN/8 CONSTANTFLOW Volume Flow Controllers for constant volume systems Type EN The art of handling air Contents Description Description 2 Application 3 Construction Dimensions Accessories 4 Dimensions
More informationINDEX. Chapter3. air master. Linear Bar Grilles
Chapter3 INDEX A Linear bar grilles: 1. Supply linear bar grille...: ASLG...3.1 2. Supply linear bar register...: ASLR...3.2 3. Return linear bar grille...: ARLG...3.3 4. Return linear bar register...:
More informationD2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS
D2 RETROFIT/YPASS TERMINA UNITS Table of Contents RETROFIT/YPASS TERMINA UNITS RVE This retrofit terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable
More informationType JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS
Homepage > Products > External Louvres & Dampers > Multileaf dampers > Multileaf dampers > Type JZ Low leakage Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Rectangular multileaf
More information500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)
500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage
More informationProduct Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm
Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA
More informationLMHS BASIC UNIT NO CONTROLS
JOB NAE ARCHITECT ENGINEER CONTRACTOR OCATION SUBITTA SHEET Form Number TS0000.10 Effective Date 6/08 Replaces Form TS0000.9 BASIC UNIT NO CONTROS CHARTED 'A' DIENSION INCUDES INET ADAPTER PROVIDED ON
More informationEX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.
25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register
More informationVariable Flow Rate Control Unit
VAV Produktdata TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S Variable Flow Rate Control Unit Model BVAV-R: VAV unit that has circular section. BVAV-RS: VAV terminal unit. BVAV-Q: VAV unit that has
More informationShut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.
X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off
More informationUniversity of Delaware
SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section
More informationCAV controllers Type RN
2.1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or return air in constant
More informationB. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.
PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationVAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE
TALE OF CONTENTS RETROFIT/YPASS TERMINAL UNITS RVE This retrofi t terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable volume systems and also
More informationC2-2. Table of Contents DUAL DUCT TERMINAL UNITS
C2 UA UCT TERINA UNITS Table of Contents UA UCT TERINA UNITS This unit features a compact design for variable volume applications where blending of hot and cold air is not required. T This unit features
More informationVAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K
. X X testregistrierung VAV terminal units Type Easy controller Compact controller Circular connection on the fan end For extract air systems with demanding acoustic requi rements VAV terminal units for
More informationLaboratory Room Single Duct Supply Air Terminal
Technical Specification Sheet Document No. 149-319A June 24th, 2010 Laboratory Room Single Duct Supply Air Terminal Features Figure 1. Laboratory Room Single Duct Supply Air Terminal. The APOGEE Automation
More informationHOW TO SPECIFY SDV UNITS
HOW TO SPECIFY SDV UNITS MODEL UNIT CONFIG LINER CASING OPTIONS CONST. SIDE INLET SIZE DISCHARGE OPTIONS CONTROL TYPE UNIT ACCESSORIES HEAT kw ELECTRIC HEAT ACCESSORIES SCR HEAT ACCESSORIES SDV 0 - Standard
More informationShut-off dampers. Type AKK. For contaminated air PD AKK 1
X X testregistrierung Shut-off dampers Type Variant with circular spigot For contaminated air Plastic circular shut-off dampers for shutting off aggressive media volume flows in air conditioning systems
More informationPressure control damper ERPA
Key features Constant pressure Real-time pressure monitoring with FW compact controller Can be connected to Modbus Available in IPSUM compatible version ERPA is a rectangular pressure control damper for
More informationType AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK
Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Type AKK FOR CONTAMINATED AIR Plastic circular shut-off dampers for shutting off aggressive
More informationApplication Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification
Date: October 22, 1999 Rev: 00 Doc. No. AG-LHK-01 Application Guide This Application Guide has been developed to introduce the LHK access floor fan powered terminal. In this Guide you will find a description
More informationCasing Hot galvanised steel / Option: stainless steel EN (AISI316L) Reheat coil EN (AISI 304)
HME Single Duct Cabin Unit Sound Attenuator And Balancing Box Available as network compatible The Halton HME can be used for air distribution and sound attenuation in various applications such as suites
More informationBOX - Airflow management unit BOX. Airflow management unit. Solution. Options & Accessories
BOX Airflow management unit Solution Airflow management and control unit Variable or constant airflow rate operation Pressure-independent operation Galvanised steel construction Airflow management plenum
More informationProduct Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm
Product Data 35E Single Duct Terminal Units for Variable Air Volume Systems Nominal 45 to 7100 cfm Single duct variable air volume (VAV) terminal units provide: 22-gage galvanized steel, unit casing lined
More informationINDEX. Chapter1 6. air master. Volume Control Dampers
Chapter1 6 INDEX 1 Volume control damper...:avcd...16.1 Standard sizes...16.2 Fixing details...16.2 How to order...16.2 Performance chart...16.3 2. Circular volume control damper....:avcd-c....16.4 Standard
More informationPressure relief dampers
X X testregistrierung Pressure relief dampers Type Closed blade For the prevention of excess pressure in rooms Pressure relief dampers for gas fire extinguishing systems and transformer substations Air
More informationDual Duct Terminal Units DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series
DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series Product Key UQ Ultra Quiet Product Selection Checklist 1] Select Unit Inlet Size based on control and acoustic parameters.
More information500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)
500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor
More informationZero Leakage Isolation Damper
SPECIFICATION The damper casing is formed from 3.0 mm thick sheet steel into a rigid channel section to ensure proper alignment of blades and shafts. Where circular dampers are required, additional spigot
More informationAIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS
AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS Airodyne multi leaf volume control tampers have been specifically designed for use in air conditioning and ventilation system for volume,
More informationHML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating
HML Airflow Unit for Large Volumes with Centralized Airflow Heating Available as network compatible Halton HML is an airflow unit for large air volumes with centralized airflow heating. The unit can be
More informationSDL Single-Duct, Low-Height, VAV Terminals
SDL -Duct, Low-Height, VAV Terminals SDL -Duct, VAV Terminals: Fit more comfort in less space Owners SDL terminals offer the typical benefits provided by single-duct units, while performing at extremely
More informationLaboratory Exhaust Air Terminal
Laboratory Exhaust Air Terminal Page 1 of 11 Figure 1. Laboratory Exhaust Air Terminal. The APOGEE Automation Laboratory Room Exhaust Air Terminal is an industrial grade, easy-to-install, prepackaged airflow
More informationType WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación
PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación > Rejas para instalación en intemperie > Rejas para instalación a intemperie > Type WG-JZ Type WG-JZ COMBINATION WITH A MULTILEAF
More informationMultileaf damper with actuator
JZ Multileaf damper with actuator FOR SHUTTING OFF THE AIRFLOW IN AIR CONDITIONING SYSTEMS Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings
More informationcatalog SDL Single-Duct, Low-Height, VAV Terminals
catalog SDL Single-Duct, Low-Height, VAV Terminals Catalog: ET130.13-EG2 (708) TABLE OF CONTENTS Single-Duct, Low-Height VAV Terminals Features and Benefits....................... 2 Controls..................................
More informationHomepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.
Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL Type KUL FOR INSTALLATION INTO DUCTWORK Non-return dampers prevent unwanted airflows
More informationType TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements
Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly
More informationHME SINGLE DUCT CABIN UNIT CABIN UNITS HME. Sound attenuator and balancing box
HME SINGLE DUCT CABIN UNIT Sound attenuator and balancing box MATERIALS APPLICATIONS Halton HME can be used for air distribution and sound attenuation in various applications such as suites and pantries.
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 23 3600 - AIR TERMINAL DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fan-powered air terminal units/devices. 2. Shut off air terminal units/devices. 3. Dual duct terminal units/devices.
More informationcatalog SDL Single-Duct, Low-Height, VAV Terminals
catalog SDL Single-Duct, Low-Height, VAV Terminals TABLE OF CONTENTS Features and Benefits.... 2 Controls.... 3 Construction Features... 4 Standard and Optional Features.... 5 Dimensional and Weight Data....
More informationType WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES
Homepage > Products > External Louvres & Dampers > External weather louvres > External weather louvres > Type WG Type WG External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS,
More informationKLIMA Active Chilled Beams
KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13
More informationAL-Maraj Central A/C Systems Accessories Mfg Co.
AL-Maraj is one of the renowned Manufacturer, Stockist and Supplier of all kinds of HVAC products, Ducting accessories, Pipe support system, Electro-mechanical and A/C Accessories in U.A.E since 2000.
More informationINDEX. Chapter2. air master. Grilles and Registers
Chapter2 INDEX A.Grilles and registers. 1. Supply air grille - front horizontal blades...: ASG-H...2.1 2. Supply air grille - front vertical blades...: ASG-V...2.2 3. Supply air register - front horizontal
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV
More informationAdditional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex
Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200
More informationCeiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades
X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling
More information