Fire/smoke damper EKO-SRBG1
|
|
- Felicia Owens
- 5 years ago
- Views:
Transcription
1 Fire/smoke damper EKO- Description The EKO- fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations. The damper is designed in compliance with current regulations. The damper is intended for in-wall installation in fire-containment sections conforming to fire-technical class up to EI 60. The ventilation duct can be left without any fire insulation whatever. A wire mesh grille should always be fitted when the damper is not connected to the ducting. CE-approval The EKO- fire/smoke damper has been tested by SP and approved by SP Certifiering and CE-marking 0402-CPR-SC Design The EKO- fire/smoke damper is available with circular duct connection as standard. The damper has a factory-mounted electrical motor with spring return, end position contacts and thermal sensor. The standard EKO- is manufactured of galvanized sheet steel (C2) with damper blades and casing of fire-resistant material. Alternatively, the damper can be made of aluzinc (C4) or stainless steel for a higher corrosivity class. The damper is fitted with a gasket to seal the air side. There is also a sealing strip on the damper that expands and seals if the damper is exposed to heat. Temperature Since the EKO- damper frame is fitted with sealing strips that expand to seal off in the event of fire, the operating temperature must not exceed 70 C. Sizes The EKO- fire/smoke damper is manufactured in seven standard sizes from Ø 100 to Ø 400 mm. For diameters between 400 mm and 630 mm use EKO-SRBG2. For diameters over 630 mm use EKO- JBG2 with circular duct connection. Product data EKO- Sizes Ø 100 Ø 400 mm (EKO-). Sizes Ø 500 Ø 630 mm (EKO-SRBG2). Nipple connection in accordance with Swedish standard. Material of manufacture: galvanized, aluzinc coated or stainless sheet steel. Fire-technical class in compliance with SS-EN 15650:2010 EI 60 (ve ho i < > o) SC Testing and classification in compliance with EN and EN CE-marking 0402-CPR-SC The damper conforms to air tightness class 2 and the casing conforms to air tightness class B according to EN 1751:1998. The damper conforms to air tightness class 2 and pressure class B according to AMA VVS & Kyl 12. The differential pressure over a closed damper can be 2500 Pa, corresponding to pressure class B. Conforms to environmental class C2. AMA VVS code QJC.2 Fire/smoke damper EKO-. EI 60 S Tel , Fax , info@ekovent.se, (9)
2 Motors The EKO- is supplied with a 24 V or 230 V electrical safety motor supplemented with a thermal sensor and test button for manual testing of functioning in situ. If the temperature exceeds 70 C inside or outside the damper, the sensor cuts off the power to the motor and the fire damper is closed. The same thing happens in the event of a power cut. A 24 V motor is always used together with the monitoring units EKO-KE 2-16 and EKOTME/TSE. A 230 V motor is used for the EKO-MKE/SKE monitoring unit. Note that the damper must always be delivered with a factory-mounted safety motor if P-certification is to be valid. Maintenance External and internal inspection Check electricity cables to the motor, smoke detectors and thermal sensor to ensure that they are not damaged. Check the damper casing, the motor attachment, damper blades and sealing strip to ensure that no damage has occurred. Function control Check that the damper is fully open when operating, closes and opens fully when tested, and closes completely when power is cut off. Otherwise follow the instructions for the EKO MKE/SKE/KE/TME/ TSE control and monitoring system. Note After inspection the fire damper should be left in normal working position. Installation Installation must always be done in accordance with the supplied installation instructions. An installation device for attaching the damper to a wall and angle brackets for ducts are included in the damper delivery. Other components, such as couplings and fire collars, must be ordered separately. The size of the hole is always the dimension of the damper + 55 mm. The pivot shaft of the damper can be installed in any position. Accessories EKO-GIS Plasterboard wall sleeve, excl. fire sealant kit. EKO-KER Fire sealing kit for wall. EKO-FNS Extension adapter with wire mesh grille. EKO-KPB Junction box. EKO-RE Smoke detector (duct). EKO-RET Smoke detector (ceiling). EKO-KE Control and monitoring system. EKO-MKE/SKE Control and monitoring system. EKO-TK Test button. EKO-TME/TSE Control and monitoring system. EKO-NRS Wire mesh grille. Cleaning We recommend preventive maintenance of the damper according to the needs of the installation. Damper blades and body (interior) should be cleaned by brushing, vacuum cleaning or wiping down. NOTE! No water or other liquid may be used. How to order the EKO- Designation: Fire/smoke damper EKO--A-B-C A B C SIZE MATERIAL MOTOR 1 = Galvanized (C2) 5 = Motor 24 V Ø 2 = Aluzinc (C4) 6 = Motor 230 V 3 = Stainless EN = Stainless EN Example: 1 Fire/smoke damper EKO Tel , Fax , info@ekovent.se, (9)
3 Technical data EKO- Dimensions EKO- C 200 B Dimensions EKO-SRBG2 B 230 ( ) 260 ( ) B EKO EKO SRBG OA OA Standard sizes and weights EKO- ØA B C Weight* ** ** ** * Weight in kg, including motor ** Extension adapter required for short connection sleeve EKO-SRBG2 ØA B C Weight* ** ** 16.2 Electrical data Dimensioning effect VA Max running time s EKO- Damper motor Safety class ** 24 V AC/DC 230 V Motor Spring BLF IP54 Dimensioning effect VA Max running time s EKO-SRBG2 Damper motor Safety class ** 24 V AC/DC 230 V Motor Spring BF IP54 Other data see separate product information. ** Applies only when cable bushing is installed downward. Circuit diagram Tel , Fax , info@ekovent.se, (9)
4 Dimensioning diagram Total pressure drop Pa L WA (db) 1 0, Air velocity m/s (damper area) Correction of sound power level in octave bands. L WAOK = L WA + K OK 90 EKO- Centre frequency (Hz) Octave band k 2k 4k 8k Correction, K OK Tolerance ± db 2,5 1, Sound power levels, pressure drop and air flow measured on a fire/smoke damper according to ISO Standard deviation (tolerance) in accordance with EN ISO 3741:2010. Tel , Fax , info@ekovent.se, (9)
5 Installation accessories EKO- Plasterboard wall sleeve EKO-GIS Installation Installation kit EKO-MOV* * Included in EKO- delivery bracket 4 pcs For attaching duct Damper bracket 4 pcs For mounting fire damper 90 Wire mesh grille EKO-NRS Used for EKO Extension adapter EKO-FNS with wire mesh grille Used for EKO and for all sizes when mounting to sleeve in wall. T Wire mesh grille Wire mesh grille Tel , Fax , info@ekovent.se, (9)
6 Mounting instructions EKO- Mounting plasterboard wall sleeve EKO-GIS Mounting damper bracket EKO-MOV 1. Bend the damper bracket 90 at the groove. Sheet metal screw or steel pop rivet 1. Squeeze the EKO-GIS sleeve and insert it in the opening. 2. Attach the sleeve at the overlap with a sheet metal screw or pop rivet. 2. Stick the tip of the bracket between the sheet metal jacket and the insulation Bend the bracket 180 over the damper jacket. 4. Attach the bracket to the wall. Tel , Fax , info@ekovent.se, (9)
7 Mounting instructions EKO- Structural element wall of plasterboard or equivalent in fire-technical class EI 60. Sheet metal screw or pop rivet of steel Damper bracket Gap min 25 mm Gap min 25 mm O A+55 EKO- EKO-GIS wall sleeve bracket Fill with EKO-KER fire sealant or similar and seal with fire protection sealant. needs no fire insulation Mounting. See special mounting instructions for EKO-MOV mounting kit. 1. Make an opening in the wall equivalent to the nominal dimensions of the damper + 55 mm, i.e. with a gap of at least 25 mm all round. 2. Attach the EKO-GIS plasterboard wall sleeve to support the fire sealant between the structural element and the ventilation duct. The EKO-GIS is not needed for mounting in a concrete/brick wall. 3. Mount the damper in the wall, centre the damper in the opening and attach with the supplied EKO- MOV sheet metal brackets (damper brackets). 4. Mount the thermal sensor with the sensor bulb in the air flow, ensuring that it does not obstruct the movement of the damper blade. 5. Mount the duct and fill the gap between the duct and the wall with fire sealant EKO-KER or similar and seal with fire protection sealant. 6. Mount the accompanying EKO-MOV sheet metal brackets (duct brackets). 7. The suspension devices for the damper and ducting must meet the requirements for the firetechnical class of the aperture. 8. In cases where the damper is mounted as a transfer air device or end plate, an EKO-NRS wire mesh grille or EKO-FNS extension adapter must be mounted. 9. The following minimum dimensions must be observed when mounting: Minimum distance between dampers: 200 mm. Minimum distance to wall/floor: 75 mm. The pivot shaft of the damper can be installed in any position. NOTE! On damper EKO the extension adapter EKO-FNS with wire mesh grille must be used since the damper blade protrudes beyond the damper sleeve in open position. Tel , Fax , info@ekovent.se, (9)
8 Mounting instructions EKO- Load-bearing structural element wall or floor of concrete, brick or aerated concrete of fire-technical class EI 60. Sheet metal screw or pop rivet of steel Damper bracket Gap min 25 mm Gap min 25 mm O A+55 EKO- bracket Fill with EKO-KER fire sealant or similar and seal with fire protection sealant. needs no fire insulation Mounting. See special mounting instructions for EKO-MOV mounting kit. 1. Make an opening in the wall equivalent to the nominal dimensions of the damper + 55 mm, i.e. with a gap of at least 25 mm all round. 2. Mount the damper in the wall, centre the damper in the opening and attach with the supplied EKO- MOV sheet metal brackets (damper brackets). 3. Mount the thermal sensor with the sensor bulb in the air flow, ensuring that it does not obstruct the movement of the damper blade. 4. Mount the duct and fill the gap between the duct and the wall with fire sealant EKO-KER or similar and seal with fire protection sealant. 5. Mount the accompanying EKO-MOV sheet metal brackets (duct brackets). 6. The suspension devices for the damper and ducting must meet the requirements for the firetechnical class of the aperture. 7. In cases where the damper is mounted as a transfer air device or end plate, an EKO-NRS wire mesh grille or EKO-FNS extension adapter must be mounted. 8. The following minimum dimensions must be observed when mounting: Minimum distance between dampers: 200 mm. Minimum distance to wall/floor: 75 mm. The pivot shaft of the damper can be installed in any position. NOTE! On damper EKO the extension adapter EKO-FNS with wire mesh grille must be used since the damper blade protrudes beyond the damper sleeve in open position. Tel , Fax , info@ekovent.se, (9)
9 Mounting instructions EKO- Structural element wall or floor structure of fire-technical class EI 60. Suspension Ø A+55 EKO- EKO- EKO- Fire sealant* Fire sealant* 1. The duct system should be suspended and insulated in accordance with the fire resistance of the structural element in which the hole is made (EI 60). Insulation of the ventilation duct must be done in accordance with Installationsbrandskydd Ventilation Rör section (ISBN: ) corresponding to the fire resistance of the structural element in which the hole is made (EI 60). NOTE! The insulation does not need to cover the damper. 2. Mount the damper in the duct. No gaps between the damper and a fire-containing structural element. Screw the damper to the duct with self-drilling screws. Check that the movement of the blade is not obstructed by the screws. 3. Mount the thermal sensor with the sensor bulb in the air flow, ensuring that it does not obstruct the movement of the damper blade. 4. The following minimum dimensions must be observed when mounting: Minimum distance between dampers: 200 mm. Minimum distance to wall/floor: 75 mm. The pivot shaft of the damper can be installed in any position. * Fire sealing must be done using an approved method that complies with the relevant firetechnical class, e.g. EKO-KER, EKO-GIS and fire protection sealant. Tel , Fax , info@ekovent.se, (9)
Smoke damper EKO-SRB1
Smoke damper EKO-SRB1 Description The EKO-SRB1 smoke damper is a CE-approved damper in fire class E60 intended for fire compartmentation or protection against the spread of fire and smoke in ventilation
More informationFire/smoke damper EKO-JBG2
Fire/smoke damper EKO-JBG2 Description The EKO-JBG2 fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.
More informationCombustion gas damper EKO-SRB
Combustion EKO-SRB Description The EKO-SRB combustion is a Class E60 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment
More informationFire/combustion gas damper EKO-JBG
Fire/combustion EKO-JBG Description The EKO-JBG fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting.
More informationFire/combustion gas damper EKO-JBL
Fire/combustion Description The fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting. The damper is designed
More informationCombustion gas damper EKO-JB
EKO-JB Description The EKO-JB combustion is a Class E6 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment wall or floor
More informationBevent Rasch BSK6. - Fire /04/2017
Bevent Rasch - Fire - BSK6 11/04/2017 Fire resistance class EI60 / EI60S Sizes from 200 x 200 mm to 800 x 800 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product
More informationBevent Rasch BSK Fire /04/2017
Bevent Rasch - Fire - BSK120 10/04/2017 Rectangular Fire resistance class /S Sizes from 200 x 200 mm to 1200 x 1000 mm Prefitted safety actuator 24V or 230V Available in MagiCAD CE-marked building product
More informationFire damper ETPR. Specifications. Product code example Fire damper ETPR
Fire damper ETPR ETPR fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 1366-2. ETPR meets the requirements of fire class EI 60 S / EI 90 S.
More informationFDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts
Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings
More information(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.
Fire damper pl-30 General characteristics Application Fire dampers prevent fire and smoke from spreading through ventilation ducts in buildings. The dampers are intended for use inside buildings and are
More informationETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE
FIRE SAFETY AIR MANAGEMENT FIRE DAMPERS ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE 2 ETPR-E-1 Fire damper Technical catalogue Fire and smoke damper ETPR-E-1 is used as a closing device for preventing the
More information7/S6 FIRE DAMPER FDC40. v 2.9 (en)
7/S6 v.9 (en) FIRE DAMPER FDC0 www.klimaoprema.hr 8 TABLE OF CONTENTS FIRE DAMPER FDC0 87 FIRE CLASSIFICATION 87 SELECTION DIAGRAM 88 ORDERING KEY 88 DAMPER MODELS 89 FDC0-M cylindrical fire damper with
More information7/S1 FIRE DAMPER PPZEN. v 2.5 (en)
7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...
More information7/S5 FIRE DAMPER FD40. v 2.9 (en)
7/S v.9 (en) FIRE DAMPER FD0 www.klimaoprema.hr 69 FIRE DAMPER - FDC TABLE OF CONTENTS FIRE DAMPER FD0 7 FIRE CLASSIFICATION 7 SELECTION DIAGRAM 7 ORDERING KEY 7 DAMPER MODELS 7 FD0-M rectangular fire
More informationFire damper FK120/FK90 TECHNICAL DATA
Fire damper FK120/FK90 TECHNICAL DATA 2 Fire damper FK120/FK90 Figure 1 ER1 Figure 2 ER3 The rectangular fire damper FK120/FK90 is available both as motorized and with fuse. The damper casing is manufactured
More informationFIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS
FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages
More informationUTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper
Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,
More informationFire dampers ETCE and ETCS TECHNICAL DATA
Fire dampers ETCE and ETCS TECHNICAL DATA 2 Fire dampers ETCE and ETCS Veloduct ETCE fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 13662.
More informationPKIR3G, PKIS, PKIS3G and PKIS3GA
PKIR3G, PKIS, PKIS3G and PKIS3GA Fire Dampers Fire resistance EI60S, EI90S and EI120S 1396 - CPR - 0076 1396 - CPR - 0077 1396 - CPD - 0062 Ordering codes Dimensions Type of activation PKIR3G 1) - ødn
More informationCRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic
Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS Perforated damper blade for better damper characteristic Manually adjustable blade (standard) Provision for motorised regulation Quick connection
More informationDKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.
Fire safety products 1 / 8 DKISMA Systemair multicompartment rectangular smoke control dampers Resistance class EI120(v ew i o) S1500C mod AAmulti 1396 - CPR - 0112 Ordering codes Nominal dimensions Type
More informationPKI-C Cartridge Fire Dampers
Fire Safety Products / 7 PKI-C Cartridge Fire Dampers Fire resistance class EI60S, EI90S and EI0S 96 - CPD - 000 Ordering codes Fire resistance class PKI-C-EI - 60S, 90S and 0S Codes section. The thermal
More informationKSOF Fire damper valve
KSOF Fire damper valve KSOF is developed for use as a fire damper valve in exhaust ventilation systems. Fire damper valve KSOF is CE marked based on product standard EN 156: and tested according to test
More informationFALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS
Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable
More informationADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection
ADAPTTM Extract Extract air diffuser for the WISE system Quick facts Active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring, Plug & Play Communication via Modbus RTU Supplied
More informationJVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6
1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators
More informationM A D E L. FOK-EIS-180 Fire dampers CE
M A D E L EN 60: FOK-EIS-80 Fire dampers CE The fire dampers FOK-EIS-80 work as a separator between two sectors of fire and ensure the same fire resistance that the structural elements of compartmentalisation,
More informationFire Dampers. Types FKA FRL FRK 4/1/EN/1
Fire Dampers Types FKA FRL FRK /1/EN/1 Contents Description Description... Construction... Standard Sizes Installation Details... Functional Description Product Range... Accessories... Circuit Diagrams...
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,
More informationseries RVV Variable flow rate controllers
series RVV Variable flow rate controllers www.koolair.com Series RVV 1 CONTENTS Variable flow rate controllers, type RVV Description 2 Dimensions and product code 3 Selection tables 4 Variable flow rate
More informationKrantz. Floor displacement outlet Q-B-DN 200. Air distribution systems
Krantz Floor displacement outlet Q-B-DN 0 Air distribution systems DS 62 E 05. Construction design Preliminary remarks Floor displacement outlets are usually used where wall or plinth displacement outlets
More informationADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection
ADAPTTM Sphere Active communicative, supply air diffuser for the WISE system Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring,
More informationCRP. Commissioning damper, Ductwork Leakage Class 0
Commissioning damper, Ductwork Leakage Class 0 Quick facts Perforated damper blade for better damper characteristic Manually adjustable blade (standard) Motorised regulation Provision for motorised regulation
More informationPART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised
FDO A0(A0) Fire Damper FDO in picture with flanges (available as an option) Halton FDO fire dampers are type-approved class A0(A0) fire dampers for use in marine and offshore ventilation systems. The FDO
More informationADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F
ADAPTTM Free Active communicative, supply air diffuser for the WISE system, ADAPT F Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple
More informationTPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD
FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD TPM 075/09-DK VALID FROM: 15/1/2012 I. CONTENT These technical specifications state a row of manufactured sizes and models of fire dampers and fire dampers
More informationRectangular fire damper TFER 30. pag. C-10
pag. C-10 Description Rectangular fire damper with CE label in conformity to UNI-EN 15650, certified according to EN 1366-2, classified EI 120 S in accordance to EN 13501-3. Removable shifted kinematic
More informationAMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers
AMCA International Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. The International
More informationTPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB
Valid from //06 EN 5650:00-09 FIRE DAMPER FDMB These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMB. It is valid for production, designing,
More informationDCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description
DCV-CF Pressure controlwith airflow measuring 24VAC + Communication Pressure control with airflow measuring DCV-CF DIN 24VAC + Communication AIN AOUT SMART DAMPERS & MEASURING UNITS PRESSURE & FLOW DCV-CF
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,
More informationFire Dampers Catalogue
Fire s Catalogue DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval UL 555 Classified 2013 For Use in Static & Dynamic Systems 3 Hour Rating Made in
More informationCircular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/
6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn
More informationlindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction
lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction Duct and fittings Content Duct and fittings Introduction...3
More informationSystemair Fire Dampers
Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S www.systemair.com As standard, all fire dampers are designed and certified to comply with EI-S performance attributes. fire dampers
More informationHeights up to 1000 mm Fire resistance period up to 120 minutes
Maintenance-free FK90 fire dampers - series FK120 - Heights up to 1000 mm Fire resistance period up to 120 minutes Fire classification: EI 30/60/90/120 (ve - ho, i o) S C10ooo Hygiene certificate Environmental
More informationDD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.
Duct Regulating Dampers Two blade options. DW144 compliant Four case options Three control options Nylon bushes as standard Suitable for vertical and horizontal ducted systems. M A N U F A C T U R E R
More informationType VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL
Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the
More informationBRC
------------------------------------------------------------- Enclosed climate beam for cooling, heating and ventilation CLIMATE BEAM is an enclosed climate beam with integrated circulation air openings
More informationSystemair Fire Dampers
Fire safety products 1 / 7 Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S 1396 - CPD - 0061 1396 - CPD - 0062 Ordering codes Ordering Codes for Circular FD: Fire resistance class
More informationWGA Long throw nozzle grille
Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation...
More informationCFSD Series. Product Description
COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke
More informationSMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS
SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00
More informationCOLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air
Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed
More informationBSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels
BSB SINGE INET ENTRIUGA AN with Backward heels BSB Series SINGE INET ENTRIUGA AN with Backward heels Kruger Ventilation Industries certifies that the BSB series shown herein is licensed to bear the AMA
More informationFD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N
V1175 FD-C Series Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper ES classified fire dampers with reduced smoke leakage characteristics (BS E 1366-2) Aerodynamically
More informationBD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S
V11711 D Series ackdraught Volume Regulating Damper Extruded aluminium blades DW144 compliant Galvanised mild steel casing with stainless steel option Flange or spigot casing options Infinite sizing capability
More informationVolume Flow Limiters Type VFL
X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered
More informationBSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels
BSB SINGE INET ENTRIFUGA FAN with Backward heels BSB Series SINGE INET ENTRIFUGA FAN with Backward heels Kruger Ventilation Industries certifies that the BSB series shown herein is licensed to bear the
More informationESAS Smoke control damper
ESAS Smoke control damper 1 Rectangular smoke control damper ESAS is specially designed to use in single fire compartment applications as a closing or as an opening damper for smoke extract purposes. ESAS
More informationOptimAir NF. Active Chilled Beam OptimAir NF. Nov
OptimAir NF Active Chilled Beam OptimAir NF Functions The OptimAir active chilled beam is a two-way induction type air-conditioningunit that is designed for integrated installation, mounted directly in
More informationTHB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser
Halton THB Perforated Ceiling Diffuser Horizontal air supply, suitable also for exhaust Installation either directly to ductwork or balancing plenum Detachable front panel enables the cleaning of the diffuser
More informationSTI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C
STI Supply air valve STI supply air valve for wall mounting covers a wide air volume area from 5 to 70 l/s, for duct sizes 100-200 mm. The valve can be quickly installed directly into the duct without
More informationApartment ventilation
GB1250 06.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box
More informationNEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION
air handling intelligence FIRE SFETY Fire Damper in libraries of EI 10 (v e -i o) S EN 13501-3+1:01 EN 15650:0 Certificate of Conformity 1488-CPD-081/W EUROPEN PTENT PPLICTION EP 01158318 GOLD MEDL MTP
More informationFire, Smoke, and Combination Fire Smoke Dampers
Fire, Smoke, and Combination Fire Smoke Dampers Installation/Configuration Fire Dampers Smoke Dampers Agenda Combination Fire/Smoke Dampers Operational Test/Inspection Periodic Test/Maintenance Damper
More informationApartment ventilation
GB1250 04.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box
More informationSlot diffusers, Round duct diffusers. IMP Klima
, Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING
More informationHEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES
HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L HD SERIES MANUFACTURERS OF AIR/FIRE/SMOKE CONTROL PRODUCTS Product Description and Features Introduction The HD Series Multi-Leaf Volume
More informationPELICAN Ceiling HF. Square extract air diffuser QUICK FACTS
Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with
More informationFire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3
SA/6/1/EN/3 Fire Dampers Type FDF Compliant to SABS (193:2004) TROX (South Africa) (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax. +27 (0)33 398 1100 email : pmb@troxsa.co.za
More informationAccessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound
Halton TSR/TSS Swirl Diffuser Radial horizontal air supply Air velocity is effectively reduced due to high mixing effect Circular duct connection with gasket All sizes available as an adapted version for
More informationEAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS
Wall air diffusers with discs for supply air and flush mounting QUICK FACTS Rotatable discs % flexible distribution pattern Cleanable Adjustable slot for enhanced capacity Simple adjustment Used together
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV
More informationCONTROL SMOKE AND BALANCING DAMPERS
(UK) Limited CONTROL SMOKE AND BALANCING DAMPERS 00 SERIES - UNIVERSAL F e a t u r e s Robust construction of galvanised steel, with stainless steel options Opposed or parallel blade pattern Unsealed,
More informationSmoke control damper RKI-90 Test certificate Z
Resistance class EK90 within smoke extraction ducts that have a fire resistance time of 90 min Ordering example / dimensions smoke control damper consisting of the housing with cut-off damper designed
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1
X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationRegulation and shut-off damper SPB and SPC
SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are
More informationFlowBar High Capacity Slot Diffuser
October 2016 FlowBar High Capacity Diffuser Model HT (High Throw) Model JT (Jet Throw) Features HT & JT 25mm, 38mm, 51mm, 63mm & 76mm s Ceiling or Sidewall Applications Modular or Continuous s Curved Sections
More informationDCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC
DCV-LC Lab climate control External occupancy detector Lab climate control unit 24VAC + Communication Occupancy DCV-LC 24VAC + Communication AIN Adjustable function AOUT Adjustable function SMART DAMPERS
More informationWall and Ceiling Grille
September 14 Wall and Ceiling Grille Models SD, DD, EC, PG, G45, NVG, NB, GN, WB and GW Single and Double Deflection Fixed and Removable Core Eggcrate Perforated Grille 45 Fixed Blade Non Vision Bar Grilles
More information1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R
1/3/EN/4 Ventilation Grilles Types TRS-K TRS-R TRSE-R Contents Description Description 2 Constructions Dimensions TRS-K 3 Constructions Dimensions TRS-R 4 Constructions Dimensions TRSE-R 5 Installation
More informationCAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1
X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting K
.1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationType DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES
Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION
More informationEX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.
25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register
More informationDCV-RC DCV-RC. DCV-RC Room climate control unit. Room climate control SMART DAMPERS & MEASURING UNITS. Product description.
DCV-RC Room climate control SMART DAMPERS & MEASURING UNITS DCV-RC Office landscape with DCV-RC. 1(18) Contents Page DCV-RC Introduction... 3 Functional chart... 4 Dimensions, Ordering format... 5 Accessories,
More informationTYPE EK-EU SMOKE CONTROL DAMPER
Homepage > PRODUCTS > Fire and Smoke Protection > Smoke Control Damper > Type EK-EU TYPE EK-EU SMOKE CONTROL DAMPER WITH TROXNETCOM AS AN OPTION CE COMPLIANT ACCORDING TO EUROPEAN REGULATIONS EK-EU WITH
More informationPK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.
Systemair Fire Dampers for Explosive Areas Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S www.systemair.com Description Fire damper (hereafter referred to as damper) is a fire
More informationClimate Recovery Duct System Technical Specifications
Climate Recovery Duct System Technical Specifications Climate Recovery (CR) Duct System Climate Recovery (CR) Duct System Overview The CR Duct System offers a complete, pre-insulated system for heating,
More informationCircular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1
X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, galvanised sheet steel construction Circular silencers Type for the reduction of noise in the circular ducts
More informationCAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1
X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air
More informationETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance
ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance 07/2013 Fläkt Woods FIFLO EN 2013.07 2 ZU CLOSED AUF OPEN Fire damper ETPS-EI Contents Operation and Maintenance
More informationNEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance
March 29 Iris Control Damper (ICD) NEW Iris Control Damper (ICD) For adjustment and measuring of airflow Features Quick and simple installation and maintenance Extended spigot connections 1% opening capacity
More informationTRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser
Halton TRB Conical Ceiling Diffuser Horizontal or vertical air supply, suitable for both heating and cooling applications Supply air jet velocity is effectively reduced due to high mixing effect Installation
More informationVAV terminal units. Type TVM. For dual duct systems PD TVM 1
X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings
More informationEnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited
April 11 EnergyShield ES EnergyShield ES Air Control and Shut off Dampers Features Dampers suitable for systems requiring air control and low closed blade leakage characteristics. Low torque characteristics.
More informationSUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130
SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 Installation dimensions AS/GS120 AS/GS130 Application The grille type AS / GS is used for the supply and exhaust of cooled or heated air in facilities
More informationCURTAIN TYPE FIRE DAMPER
MODEL: IBD-2 / IBD-2H STANDARD CONSTRUCTION FIRE RATING UL 555 1-1/2 hours UL classification damper SS: 4 hours rating classification damper NOTES Damper s dimension is usually about 10 mm smaller than
More information