Fire/smoke damper EKO-SRBG1

Size: px
Start display at page:

Download "Fire/smoke damper EKO-SRBG1"

Transcription

1 Fire/smoke damper EKO- Description The EKO- fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations. The damper is designed in compliance with current regulations. The damper is intended for in-wall installation in fire-containment sections conforming to fire-technical class up to EI 60. The ventilation duct can be left without any fire insulation whatever. A wire mesh grille should always be fitted when the damper is not connected to the ducting. CE-approval The EKO- fire/smoke damper has been tested by SP and approved by SP Certifiering and CE-marking 0402-CPR-SC Design The EKO- fire/smoke damper is available with circular duct connection as standard. The damper has a factory-mounted electrical motor with spring return, end position contacts and thermal sensor. The standard EKO- is manufactured of galvanized sheet steel (C2) with damper blades and casing of fire-resistant material. Alternatively, the damper can be made of aluzinc (C4) or stainless steel for a higher corrosivity class. The damper is fitted with a gasket to seal the air side. There is also a sealing strip on the damper that expands and seals if the damper is exposed to heat. Temperature Since the EKO- damper frame is fitted with sealing strips that expand to seal off in the event of fire, the operating temperature must not exceed 70 C. Sizes The EKO- fire/smoke damper is manufactured in seven standard sizes from Ø 100 to Ø 400 mm. For diameters between 400 mm and 630 mm use EKO-SRBG2. For diameters over 630 mm use EKO- JBG2 with circular duct connection. Product data EKO- Sizes Ø 100 Ø 400 mm (EKO-). Sizes Ø 500 Ø 630 mm (EKO-SRBG2). Nipple connection in accordance with Swedish standard. Material of manufacture: galvanized, aluzinc coated or stainless sheet steel. Fire-technical class in compliance with SS-EN 15650:2010 EI 60 (ve ho i < > o) SC Testing and classification in compliance with EN and EN CE-marking 0402-CPR-SC The damper conforms to air tightness class 2 and the casing conforms to air tightness class B according to EN 1751:1998. The damper conforms to air tightness class 2 and pressure class B according to AMA VVS & Kyl 12. The differential pressure over a closed damper can be 2500 Pa, corresponding to pressure class B. Conforms to environmental class C2. AMA VVS code QJC.2 Fire/smoke damper EKO-. EI 60 S Tel , Fax , info@ekovent.se, (9)

2 Motors The EKO- is supplied with a 24 V or 230 V electrical safety motor supplemented with a thermal sensor and test button for manual testing of functioning in situ. If the temperature exceeds 70 C inside or outside the damper, the sensor cuts off the power to the motor and the fire damper is closed. The same thing happens in the event of a power cut. A 24 V motor is always used together with the monitoring units EKO-KE 2-16 and EKOTME/TSE. A 230 V motor is used for the EKO-MKE/SKE monitoring unit. Note that the damper must always be delivered with a factory-mounted safety motor if P-certification is to be valid. Maintenance External and internal inspection Check electricity cables to the motor, smoke detectors and thermal sensor to ensure that they are not damaged. Check the damper casing, the motor attachment, damper blades and sealing strip to ensure that no damage has occurred. Function control Check that the damper is fully open when operating, closes and opens fully when tested, and closes completely when power is cut off. Otherwise follow the instructions for the EKO MKE/SKE/KE/TME/ TSE control and monitoring system. Note After inspection the fire damper should be left in normal working position. Installation Installation must always be done in accordance with the supplied installation instructions. An installation device for attaching the damper to a wall and angle brackets for ducts are included in the damper delivery. Other components, such as couplings and fire collars, must be ordered separately. The size of the hole is always the dimension of the damper + 55 mm. The pivot shaft of the damper can be installed in any position. Accessories EKO-GIS Plasterboard wall sleeve, excl. fire sealant kit. EKO-KER Fire sealing kit for wall. EKO-FNS Extension adapter with wire mesh grille. EKO-KPB Junction box. EKO-RE Smoke detector (duct). EKO-RET Smoke detector (ceiling). EKO-KE Control and monitoring system. EKO-MKE/SKE Control and monitoring system. EKO-TK Test button. EKO-TME/TSE Control and monitoring system. EKO-NRS Wire mesh grille. Cleaning We recommend preventive maintenance of the damper according to the needs of the installation. Damper blades and body (interior) should be cleaned by brushing, vacuum cleaning or wiping down. NOTE! No water or other liquid may be used. How to order the EKO- Designation: Fire/smoke damper EKO--A-B-C A B C SIZE MATERIAL MOTOR 1 = Galvanized (C2) 5 = Motor 24 V Ø 2 = Aluzinc (C4) 6 = Motor 230 V 3 = Stainless EN = Stainless EN Example: 1 Fire/smoke damper EKO Tel , Fax , info@ekovent.se, (9)

3 Technical data EKO- Dimensions EKO- C 200 B Dimensions EKO-SRBG2 B 230 ( ) 260 ( ) B EKO EKO SRBG OA OA Standard sizes and weights EKO- ØA B C Weight* ** ** ** * Weight in kg, including motor ** Extension adapter required for short connection sleeve EKO-SRBG2 ØA B C Weight* ** ** 16.2 Electrical data Dimensioning effect VA Max running time s EKO- Damper motor Safety class ** 24 V AC/DC 230 V Motor Spring BLF IP54 Dimensioning effect VA Max running time s EKO-SRBG2 Damper motor Safety class ** 24 V AC/DC 230 V Motor Spring BF IP54 Other data see separate product information. ** Applies only when cable bushing is installed downward. Circuit diagram Tel , Fax , info@ekovent.se, (9)

4 Dimensioning diagram Total pressure drop Pa L WA (db) 1 0, Air velocity m/s (damper area) Correction of sound power level in octave bands. L WAOK = L WA + K OK 90 EKO- Centre frequency (Hz) Octave band k 2k 4k 8k Correction, K OK Tolerance ± db 2,5 1, Sound power levels, pressure drop and air flow measured on a fire/smoke damper according to ISO Standard deviation (tolerance) in accordance with EN ISO 3741:2010. Tel , Fax , info@ekovent.se, (9)

5 Installation accessories EKO- Plasterboard wall sleeve EKO-GIS Installation Installation kit EKO-MOV* * Included in EKO- delivery bracket 4 pcs For attaching duct Damper bracket 4 pcs For mounting fire damper 90 Wire mesh grille EKO-NRS Used for EKO Extension adapter EKO-FNS with wire mesh grille Used for EKO and for all sizes when mounting to sleeve in wall. T Wire mesh grille Wire mesh grille Tel , Fax , info@ekovent.se, (9)

6 Mounting instructions EKO- Mounting plasterboard wall sleeve EKO-GIS Mounting damper bracket EKO-MOV 1. Bend the damper bracket 90 at the groove. Sheet metal screw or steel pop rivet 1. Squeeze the EKO-GIS sleeve and insert it in the opening. 2. Attach the sleeve at the overlap with a sheet metal screw or pop rivet. 2. Stick the tip of the bracket between the sheet metal jacket and the insulation Bend the bracket 180 over the damper jacket. 4. Attach the bracket to the wall. Tel , Fax , info@ekovent.se, (9)

7 Mounting instructions EKO- Structural element wall of plasterboard or equivalent in fire-technical class EI 60. Sheet metal screw or pop rivet of steel Damper bracket Gap min 25 mm Gap min 25 mm O A+55 EKO- EKO-GIS wall sleeve bracket Fill with EKO-KER fire sealant or similar and seal with fire protection sealant. needs no fire insulation Mounting. See special mounting instructions for EKO-MOV mounting kit. 1. Make an opening in the wall equivalent to the nominal dimensions of the damper + 55 mm, i.e. with a gap of at least 25 mm all round. 2. Attach the EKO-GIS plasterboard wall sleeve to support the fire sealant between the structural element and the ventilation duct. The EKO-GIS is not needed for mounting in a concrete/brick wall. 3. Mount the damper in the wall, centre the damper in the opening and attach with the supplied EKO- MOV sheet metal brackets (damper brackets). 4. Mount the thermal sensor with the sensor bulb in the air flow, ensuring that it does not obstruct the movement of the damper blade. 5. Mount the duct and fill the gap between the duct and the wall with fire sealant EKO-KER or similar and seal with fire protection sealant. 6. Mount the accompanying EKO-MOV sheet metal brackets (duct brackets). 7. The suspension devices for the damper and ducting must meet the requirements for the firetechnical class of the aperture. 8. In cases where the damper is mounted as a transfer air device or end plate, an EKO-NRS wire mesh grille or EKO-FNS extension adapter must be mounted. 9. The following minimum dimensions must be observed when mounting: Minimum distance between dampers: 200 mm. Minimum distance to wall/floor: 75 mm. The pivot shaft of the damper can be installed in any position. NOTE! On damper EKO the extension adapter EKO-FNS with wire mesh grille must be used since the damper blade protrudes beyond the damper sleeve in open position. Tel , Fax , info@ekovent.se, (9)

8 Mounting instructions EKO- Load-bearing structural element wall or floor of concrete, brick or aerated concrete of fire-technical class EI 60. Sheet metal screw or pop rivet of steel Damper bracket Gap min 25 mm Gap min 25 mm O A+55 EKO- bracket Fill with EKO-KER fire sealant or similar and seal with fire protection sealant. needs no fire insulation Mounting. See special mounting instructions for EKO-MOV mounting kit. 1. Make an opening in the wall equivalent to the nominal dimensions of the damper + 55 mm, i.e. with a gap of at least 25 mm all round. 2. Mount the damper in the wall, centre the damper in the opening and attach with the supplied EKO- MOV sheet metal brackets (damper brackets). 3. Mount the thermal sensor with the sensor bulb in the air flow, ensuring that it does not obstruct the movement of the damper blade. 4. Mount the duct and fill the gap between the duct and the wall with fire sealant EKO-KER or similar and seal with fire protection sealant. 5. Mount the accompanying EKO-MOV sheet metal brackets (duct brackets). 6. The suspension devices for the damper and ducting must meet the requirements for the firetechnical class of the aperture. 7. In cases where the damper is mounted as a transfer air device or end plate, an EKO-NRS wire mesh grille or EKO-FNS extension adapter must be mounted. 8. The following minimum dimensions must be observed when mounting: Minimum distance between dampers: 200 mm. Minimum distance to wall/floor: 75 mm. The pivot shaft of the damper can be installed in any position. NOTE! On damper EKO the extension adapter EKO-FNS with wire mesh grille must be used since the damper blade protrudes beyond the damper sleeve in open position. Tel , Fax , info@ekovent.se, (9)

9 Mounting instructions EKO- Structural element wall or floor structure of fire-technical class EI 60. Suspension Ø A+55 EKO- EKO- EKO- Fire sealant* Fire sealant* 1. The duct system should be suspended and insulated in accordance with the fire resistance of the structural element in which the hole is made (EI 60). Insulation of the ventilation duct must be done in accordance with Installationsbrandskydd Ventilation Rör section (ISBN: ) corresponding to the fire resistance of the structural element in which the hole is made (EI 60). NOTE! The insulation does not need to cover the damper. 2. Mount the damper in the duct. No gaps between the damper and a fire-containing structural element. Screw the damper to the duct with self-drilling screws. Check that the movement of the blade is not obstructed by the screws. 3. Mount the thermal sensor with the sensor bulb in the air flow, ensuring that it does not obstruct the movement of the damper blade. 4. The following minimum dimensions must be observed when mounting: Minimum distance between dampers: 200 mm. Minimum distance to wall/floor: 75 mm. The pivot shaft of the damper can be installed in any position. * Fire sealing must be done using an approved method that complies with the relevant firetechnical class, e.g. EKO-KER, EKO-GIS and fire protection sealant. Tel , Fax , info@ekovent.se, (9)

Smoke damper EKO-SRB1

Smoke damper EKO-SRB1 Smoke damper EKO-SRB1 Description The EKO-SRB1 smoke damper is a CE-approved damper in fire class E60 intended for fire compartmentation or protection against the spread of fire and smoke in ventilation

More information

Fire/smoke damper EKO-JBG2

Fire/smoke damper EKO-JBG2 Fire/smoke damper EKO-JBG2 Description The EKO-JBG2 fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.

More information

Combustion gas damper EKO-SRB

Combustion gas damper EKO-SRB Combustion EKO-SRB Description The EKO-SRB combustion is a Class E60 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment

More information

Fire/combustion gas damper EKO-JBG

Fire/combustion gas damper EKO-JBG Fire/combustion EKO-JBG Description The EKO-JBG fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting.

More information

Fire/combustion gas damper EKO-JBL

Fire/combustion gas damper EKO-JBL Fire/combustion Description The fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting. The damper is designed

More information

Combustion gas damper EKO-JB

Combustion gas damper EKO-JB EKO-JB Description The EKO-JB combustion is a Class E6 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment wall or floor

More information

Bevent Rasch BSK6. - Fire /04/2017

Bevent Rasch BSK6. - Fire /04/2017 Bevent Rasch - Fire - BSK6 11/04/2017 Fire resistance class EI60 / EI60S Sizes from 200 x 200 mm to 800 x 800 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product

More information

Bevent Rasch BSK Fire /04/2017

Bevent Rasch BSK Fire /04/2017 Bevent Rasch - Fire - BSK120 10/04/2017 Rectangular Fire resistance class /S Sizes from 200 x 200 mm to 1200 x 1000 mm Prefitted safety actuator 24V or 230V Available in MagiCAD CE-marked building product

More information

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

Fire damper ETPR. Specifications. Product code example Fire damper ETPR Fire damper ETPR ETPR fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 1366-2. ETPR meets the requirements of fire class EI 60 S / EI 90 S.

More information

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings

More information

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm. Fire damper pl-30 General characteristics Application Fire dampers prevent fire and smoke from spreading through ventilation ducts in buildings. The dampers are intended for use inside buildings and are

More information

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR MANAGEMENT FIRE DAMPERS ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE 2 ETPR-E-1 Fire damper Technical catalogue Fire and smoke damper ETPR-E-1 is used as a closing device for preventing the

More information

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

7/S6 FIRE DAMPER FDC40. v 2.9 (en) 7/S6 v.9 (en) FIRE DAMPER FDC0 www.klimaoprema.hr 8 TABLE OF CONTENTS FIRE DAMPER FDC0 87 FIRE CLASSIFICATION 87 SELECTION DIAGRAM 88 ORDERING KEY 88 DAMPER MODELS 89 FDC0-M cylindrical fire damper with

More information

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

7/S1 FIRE DAMPER PPZEN. v 2.5 (en) 7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...

More information

7/S5 FIRE DAMPER FD40. v 2.9 (en)

7/S5 FIRE DAMPER FD40. v 2.9 (en) 7/S v.9 (en) FIRE DAMPER FD0 www.klimaoprema.hr 69 FIRE DAMPER - FDC TABLE OF CONTENTS FIRE DAMPER FD0 7 FIRE CLASSIFICATION 7 SELECTION DIAGRAM 7 ORDERING KEY 7 DAMPER MODELS 7 FD0-M rectangular fire

More information

Fire damper FK120/FK90 TECHNICAL DATA

Fire damper FK120/FK90 TECHNICAL DATA Fire damper FK120/FK90 TECHNICAL DATA 2 Fire damper FK120/FK90 Figure 1 ER1 Figure 2 ER3 The rectangular fire damper FK120/FK90 is available both as motorized and with fuse. The damper casing is manufactured

More information

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages

More information

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,

More information

Fire dampers ETCE and ETCS TECHNICAL DATA

Fire dampers ETCE and ETCS TECHNICAL DATA Fire dampers ETCE and ETCS TECHNICAL DATA 2 Fire dampers ETCE and ETCS Veloduct ETCE fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 13662.

More information

PKIR3G, PKIS, PKIS3G and PKIS3GA

PKIR3G, PKIS, PKIS3G and PKIS3GA PKIR3G, PKIS, PKIS3G and PKIS3GA Fire Dampers Fire resistance EI60S, EI90S and EI120S 1396 - CPR - 0076 1396 - CPR - 0077 1396 - CPD - 0062 Ordering codes Dimensions Type of activation PKIR3G 1) - ødn

More information

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS Perforated damper blade for better damper characteristic Manually adjustable blade (standard) Provision for motorised regulation Quick connection

More information

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8. Fire safety products 1 / 8 DKISMA Systemair multicompartment rectangular smoke control dampers Resistance class EI120(v ew i o) S1500C mod AAmulti 1396 - CPR - 0112 Ordering codes Nominal dimensions Type

More information

PKI-C Cartridge Fire Dampers

PKI-C Cartridge Fire Dampers Fire Safety Products / 7 PKI-C Cartridge Fire Dampers Fire resistance class EI60S, EI90S and EI0S 96 - CPD - 000 Ordering codes Fire resistance class PKI-C-EI - 60S, 90S and 0S Codes section. The thermal

More information

KSOF Fire damper valve

KSOF Fire damper valve KSOF Fire damper valve KSOF is developed for use as a fire damper valve in exhaust ventilation systems. Fire damper valve KSOF is CE marked based on product standard EN 156: and tested according to test

More information

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable

More information

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection ADAPTTM Extract Extract air diffuser for the WISE system Quick facts Active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring, Plug & Play Communication via Modbus RTU Supplied

More information

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators

More information

M A D E L. FOK-EIS-180 Fire dampers CE

M A D E L. FOK-EIS-180 Fire dampers CE M A D E L EN 60: FOK-EIS-80 Fire dampers CE The fire dampers FOK-EIS-80 work as a separator between two sectors of fire and ensure the same fire resistance that the structural elements of compartmentalisation,

More information

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Fire Dampers. Types FKA FRL FRK 4/1/EN/1 Fire Dampers Types FKA FRL FRK /1/EN/1 Contents Description Description... Construction... Standard Sizes Installation Details... Functional Description Product Range... Accessories... Circuit Diagrams...

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

series RVV Variable flow rate controllers

series RVV Variable flow rate controllers series RVV Variable flow rate controllers www.koolair.com Series RVV 1 CONTENTS Variable flow rate controllers, type RVV Description 2 Dimensions and product code 3 Selection tables 4 Variable flow rate

More information

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems Krantz Floor displacement outlet Q-B-DN 0 Air distribution systems DS 62 E 05. Construction design Preliminary remarks Floor displacement outlets are usually used where wall or plinth displacement outlets

More information

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection ADAPTTM Sphere Active communicative, supply air diffuser for the WISE system Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring,

More information

CRP. Commissioning damper, Ductwork Leakage Class 0

CRP. Commissioning damper, Ductwork Leakage Class 0 Commissioning damper, Ductwork Leakage Class 0 Quick facts Perforated damper blade for better damper characteristic Manually adjustable blade (standard) Motorised regulation Provision for motorised regulation

More information

PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised

PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised FDO A0(A0) Fire Damper FDO in picture with flanges (available as an option) Halton FDO fire dampers are type-approved class A0(A0) fire dampers for use in marine and offshore ventilation systems. The FDO

More information

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F ADAPTTM Free Active communicative, supply air diffuser for the WISE system, ADAPT F Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple

More information

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD TPM 075/09-DK VALID FROM: 15/1/2012 I. CONTENT These technical specifications state a row of manufactured sizes and models of fire dampers and fire dampers

More information

Rectangular fire damper TFER 30. pag. C-10

Rectangular fire damper TFER 30. pag. C-10 pag. C-10 Description Rectangular fire damper with CE label in conformity to UNI-EN 15650, certified according to EN 1366-2, classified EI 120 S in accordance to EN 13501-3. Removable shifted kinematic

More information

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers AMCA International Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. The International

More information

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB Valid from //06 EN 5650:00-09 FIRE DAMPER FDMB These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMB. It is valid for production, designing,

More information

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description DCV-CF Pressure controlwith airflow measuring 24VAC + Communication Pressure control with airflow measuring DCV-CF DIN 24VAC + Communication AIN AOUT SMART DAMPERS & MEASURING UNITS PRESSURE & FLOW DCV-CF

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,

More information

Fire Dampers Catalogue

Fire Dampers Catalogue Fire s Catalogue DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval UL 555 Classified 2013 For Use in Static & Dynamic Systems 3 Hour Rating Made in

More information

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/ 6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction

lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction Duct and fittings Content Duct and fittings Introduction...3

More information

Systemair Fire Dampers

Systemair Fire Dampers Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S www.systemair.com As standard, all fire dampers are designed and certified to comply with EI-S performance attributes. fire dampers

More information

Heights up to 1000 mm Fire resistance period up to 120 minutes

Heights up to 1000 mm Fire resistance period up to 120 minutes Maintenance-free FK90 fire dampers - series FK120 - Heights up to 1000 mm Fire resistance period up to 120 minutes Fire classification: EI 30/60/90/120 (ve - ho, i o) S C10ooo Hygiene certificate Environmental

More information

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options. Duct Regulating Dampers Two blade options. DW144 compliant Four case options Three control options Nylon bushes as standard Suitable for vertical and horizontal ducted systems. M A N U F A C T U R E R

More information

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the

More information

BRC

BRC ------------------------------------------------------------- Enclosed climate beam for cooling, heating and ventilation CLIMATE BEAM is an enclosed climate beam with integrated circulation air openings

More information

Systemair Fire Dampers

Systemair Fire Dampers Fire safety products 1 / 7 Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S 1396 - CPD - 0061 1396 - CPD - 0062 Ordering codes Ordering Codes for Circular FD: Fire resistance class

More information

WGA Long throw nozzle grille

WGA Long throw nozzle grille Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation...

More information

CFSD Series. Product Description

CFSD Series. Product Description COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke

More information

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00

More information

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed

More information

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels BSB SINGE INET ENTRIUGA AN with Backward heels BSB Series SINGE INET ENTRIUGA AN with Backward heels Kruger Ventilation Industries certifies that the BSB series shown herein is licensed to bear the AMA

More information

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N V1175 FD-C Series Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper ES classified fire dampers with reduced smoke leakage characteristics (BS E 1366-2) Aerodynamically

More information

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S V11711 D Series ackdraught Volume Regulating Damper Extruded aluminium blades DW144 compliant Galvanised mild steel casing with stainless steel option Flange or spigot casing options Infinite sizing capability

More information

Volume Flow Limiters Type VFL

Volume Flow Limiters Type VFL X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered

More information

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels BSB SINGE INET ENTRIFUGA FAN with Backward heels BSB Series SINGE INET ENTRIFUGA FAN with Backward heels Kruger Ventilation Industries certifies that the BSB series shown herein is licensed to bear the

More information

ESAS Smoke control damper

ESAS Smoke control damper ESAS Smoke control damper 1 Rectangular smoke control damper ESAS is specially designed to use in single fire compartment applications as a closing or as an opening damper for smoke extract purposes. ESAS

More information

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

OptimAir NF. Active Chilled Beam OptimAir NF. Nov OptimAir NF Active Chilled Beam OptimAir NF Functions The OptimAir active chilled beam is a two-way induction type air-conditioningunit that is designed for integrated installation, mounted directly in

More information

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser Halton THB Perforated Ceiling Diffuser Horizontal air supply, suitable also for exhaust Installation either directly to ductwork or balancing plenum Detachable front panel enables the cleaning of the diffuser

More information

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C STI Supply air valve STI supply air valve for wall mounting covers a wide air volume area from 5 to 70 l/s, for duct sizes 100-200 mm. The valve can be quickly installed directly into the duct without

More information

Apartment ventilation

Apartment ventilation GB1250 06.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box

More information

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION air handling intelligence FIRE SFETY Fire Damper in libraries of EI 10 (v e -i o) S EN 13501-3+1:01 EN 15650:0 Certificate of Conformity 1488-CPD-081/W EUROPEN PTENT PPLICTION EP 01158318 GOLD MEDL MTP

More information

Fire, Smoke, and Combination Fire Smoke Dampers

Fire, Smoke, and Combination Fire Smoke Dampers Fire, Smoke, and Combination Fire Smoke Dampers Installation/Configuration Fire Dampers Smoke Dampers Agenda Combination Fire/Smoke Dampers Operational Test/Inspection Periodic Test/Maintenance Damper

More information

Apartment ventilation

Apartment ventilation GB1250 04.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box

More information

Slot diffusers, Round duct diffusers. IMP Klima

Slot diffusers, Round duct diffusers. IMP Klima , Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING

More information

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L HD SERIES MANUFACTURERS OF AIR/FIRE/SMOKE CONTROL PRODUCTS Product Description and Features Introduction The HD Series Multi-Leaf Volume

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3 SA/6/1/EN/3 Fire Dampers Type FDF Compliant to SABS (193:2004) TROX (South Africa) (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax. +27 (0)33 398 1100 email : pmb@troxsa.co.za

More information

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound Halton TSR/TSS Swirl Diffuser Radial horizontal air supply Air velocity is effectively reduced due to high mixing effect Circular duct connection with gasket All sizes available as an adapted version for

More information

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS Wall air diffusers with discs for supply air and flush mounting QUICK FACTS Rotatable discs % flexible distribution pattern Cleanable Adjustable slot for enhanced capacity Simple adjustment Used together

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV

More information

CONTROL SMOKE AND BALANCING DAMPERS

CONTROL SMOKE AND BALANCING DAMPERS (UK) Limited CONTROL SMOKE AND BALANCING DAMPERS 00 SERIES - UNIVERSAL F e a t u r e s Robust construction of galvanised steel, with stainless steel options Opposed or parallel blade pattern Unsealed,

More information

Smoke control damper RKI-90 Test certificate Z

Smoke control damper RKI-90 Test certificate Z Resistance class EK90 within smoke extraction ducts that have a fire resistance time of 90 min Ordering example / dimensions smoke control damper consisting of the housing with cut-off damper designed

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

Regulation and shut-off damper SPB and SPC

Regulation and shut-off damper SPB and SPC SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are

More information

FlowBar High Capacity Slot Diffuser

FlowBar High Capacity Slot Diffuser October 2016 FlowBar High Capacity Diffuser Model HT (High Throw) Model JT (Jet Throw) Features HT & JT 25mm, 38mm, 51mm, 63mm & 76mm s Ceiling or Sidewall Applications Modular or Continuous s Curved Sections

More information

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC DCV-LC Lab climate control External occupancy detector Lab climate control unit 24VAC + Communication Occupancy DCV-LC 24VAC + Communication AIN Adjustable function AOUT Adjustable function SMART DAMPERS

More information

Wall and Ceiling Grille

Wall and Ceiling Grille September 14 Wall and Ceiling Grille Models SD, DD, EC, PG, G45, NVG, NB, GN, WB and GW Single and Double Deflection Fixed and Removable Core Eggcrate Perforated Grille 45 Fixed Blade Non Vision Bar Grilles

More information

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R 1/3/EN/4 Ventilation Grilles Types TRS-K TRS-R TRSE-R Contents Description Description 2 Constructions Dimensions TRS-K 3 Constructions Dimensions TRS-R 4 Constructions Dimensions TRSE-R 5 Installation

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION

More information

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES. 25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register

More information

DCV-RC DCV-RC. DCV-RC Room climate control unit. Room climate control SMART DAMPERS & MEASURING UNITS. Product description.

DCV-RC DCV-RC. DCV-RC Room climate control unit. Room climate control SMART DAMPERS & MEASURING UNITS. Product description. DCV-RC Room climate control SMART DAMPERS & MEASURING UNITS DCV-RC Office landscape with DCV-RC. 1(18) Contents Page DCV-RC Introduction... 3 Functional chart... 4 Dimensions, Ordering format... 5 Accessories,

More information

TYPE EK-EU SMOKE CONTROL DAMPER

TYPE EK-EU SMOKE CONTROL DAMPER Homepage > PRODUCTS > Fire and Smoke Protection > Smoke Control Damper > Type EK-EU TYPE EK-EU SMOKE CONTROL DAMPER WITH TROXNETCOM AS AN OPTION CE COMPLIANT ACCORDING TO EUROPEAN REGULATIONS EK-EU WITH

More information

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas. Systemair Fire Dampers for Explosive Areas Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S www.systemair.com Description Fire damper (hereafter referred to as damper) is a fire

More information

Climate Recovery Duct System Technical Specifications

Climate Recovery Duct System Technical Specifications Climate Recovery Duct System Technical Specifications Climate Recovery (CR) Duct System Climate Recovery (CR) Duct System Overview The CR Duct System offers a complete, pre-insulated system for heating,

More information

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1 X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, galvanised sheet steel construction Circular silencers Type for the reduction of noise in the circular ducts

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance 07/2013 Fläkt Woods FIFLO EN 2013.07 2 ZU CLOSED AUF OPEN Fire damper ETPS-EI Contents Operation and Maintenance

More information

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance March 29 Iris Control Damper (ICD) NEW Iris Control Damper (ICD) For adjustment and measuring of airflow Features Quick and simple installation and maintenance Extended spigot connections 1% opening capacity

More information

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser Halton TRB Conical Ceiling Diffuser Horizontal or vertical air supply, suitable for both heating and cooling applications Supply air jet velocity is effectively reduced due to high mixing effect Installation

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited April 11 EnergyShield ES EnergyShield ES Air Control and Shut off Dampers Features Dampers suitable for systems requiring air control and low closed blade leakage characteristics. Low torque characteristics.

More information

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 Installation dimensions AS/GS120 AS/GS130 Application The grille type AS / GS is used for the supply and exhaust of cooled or heated air in facilities

More information

CURTAIN TYPE FIRE DAMPER

CURTAIN TYPE FIRE DAMPER MODEL: IBD-2 / IBD-2H STANDARD CONSTRUCTION FIRE RATING UL 555 1-1/2 hours UL classification damper SS: 4 hours rating classification damper NOTES Damper s dimension is usually about 10 mm smaller than

More information