PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised
|
|
- Meghan Felicity Walsh
- 5 years ago
- Views:
Transcription
1 FDO A0(A0) Fire Damper FDO in picture with flanges (available as an option) Halton FDO fire dampers are type-approved class A0(A0) fire dampers for use in marine and offshore ventilation systems. The FDO can be installed in circular ducts. All fire dampers have a fusible link and they prevent the spread of fire within the ventilation ductwork. When the blade is in the open position, the device does not cause significant pressure loss, noise or flow disturbance. Fire dampers are set from outside and can be installed in any position. An open-closed indicator is visible on the outside of the damper. Type-approved by most recognized classification societies, class A0 - A0 fire damper when suitably insulated Fixed frame of painted, galvanized or stainless steel. Blades stainless or galvanized steel. Flanges available as an option. Blade contains seals (effective up to 20 ºC) Nominal fuse release temperature 50 ºC, 4 ºC or 100 ºC. Other temperatures available. Very low leakage Automatic electrical, pneumatic or spring operation system available Maximum duct pressure for damper construction 5000 Pa and maximum air velocity 15 m/s PART MATERIAL FINISHIN Frame Carbon steel Painted or galvanised Frame Stainless steel EN (AISI04), EN (AISI1L), EN (AISI1L) - Blades Steel alvanized Blades Stainless steel EN (AISI04), EN (AISI1L), EN (AISI1L) - Maintenance-free bearings Stainless steel EN (AISI1L) - Shafts Stainless steel EN (AISI1L) - FDO - A0(A0) Fire Damper 5
2 I I I FDO DIMENSIONS AND MATERIAL THICKNESS FDO fire dampers meet international standards for circular ducts (Ø mm). Sizes Ø100 and Ø125 are not available of stainless steel. Sizes starting from Ø10 can be manufactured with 1 mm division. Flanges and drilling available as an option and according to ISO 151 standards. Special flanges and drilling available on request. Frame material thickness according to SOLAS. ENERAL FDO DRAWIN (without flanges) I T Alt. Position of the actuator A C F FDO DRAWIN (with flanges) H T E ØD Alt. position of the actuator Damper Blade A B F C H FDO - A0(A0) Fire Damper
3 FDO Dimensions without flanges (standard) FDO Dimensions with flanges (as an option) FDO-EL FDO-PNR FDO-SP Damper Inside Outside Material Housing Blade Elodrive CSQP Belimo Air Torque Air Torque Spring size dimensions dimensions thickness Lenght /Schischek BF AT50 AT100 Ø A C T F H I H I H I H I H I , 10, FDO-EL FDO-PNR FDO-SP Damper Inside Bolt Outside Material Bolt Bolt holes Housing Blade Elodrive CSQP/ Belimo Air Torque Spring size dimensions circle dimensions thickness holes Qty Lenght Schischek BF AT 50 Ø A B C T D E F H I H I H I H I , ,, , , , VM09Y2015/Halton Marine reserves the right to alter products without notice. WEIHTS OF STANDARD HALTON MARINE FDO DAMPERS (K) without an actuator FDO weight without flanges FDO weight with flanges Size ØD (mm) K Size ØD (mm) K ,5 200, , , , , ,5 Weights stated above do not include flanges or any actuator. Examples of actuator weights: FDO-EL CSQP +,5 kg, BF20 +,2 kg, BLF20 +1, kg, ExMax or RedMax or InMax +,5 kg, FDO-PNR AT100 (AISI) +,2 kg, AT50 (AISI) + kg, FDO-SP +1 kg. FDO - A0(A0) Fire Damper
4 FDO PRODUCT OPTIONS Halton FDO is available with following actuators: FDO-EL: Electrical spring return motor; standard actuators being 24 V or 20 V or 120 V. The motor contains built-in open-closed limit switches. Separate junction box included in the EL-model. A wide range of eex-proof actuators available, including a one second closing time function as an option. FDO-PNR: Pneumatic rotating actuator FDO-SP: Manual spring-actuated damper with fusible link DOT: manual override function available for PNR models. A wide range of accessories available. OPERATION PRINCIPLE In the event of a temperature rise in ductwork: FDO-EL: fusible link releases and cuts off operating voltage to the spring return motor, allowing the spring to close the damper blades. The fire damper opens automatically when the fuse has been changed and the operating voltage to the motor is re-established. FDO-PNR: fusible link releases and cuts off operating pressure to the spring return actuator, allowing springs to close the damper blades. The fire damper opens automatically when the fuse has been changed and the pneumatic air supply is re-established. FDO-SP: fusible link releases allowing the spring to close the damper blades. When the fuse has been changed, the fire damper must be reset into open position manually. FDO LEAKAE CLASS ACCORDIN TO STANDARD EN151 Size ØD (mm) Closed blade leakage Casing leakage C C 10 C 200 C 250 C 15 C 400 C 500 C FDO-EL WIRIN DIARAM with Elodrive CSQP FDO-EL WIRIN DIARAM with Belimo actuator POWER SUPPLY 120/20 V AC L N POWER SUPPLY 120 V AC DAMPER DAMPER CLOSED OPEN 4 L 1 14 N (+) 1 14 (-) S1 S2 S S4 S5 S 2 x 0,5 mm² x 0,5 mm² SIHF 2 x 0,5 mm² 14 1 FUSIBLE LINK x 0,5 mm² N T - L1 ~ + ELODRIVE CSQP-15A1E 15A2E 10A1E 10A2E 05A2E 05A2E IP SIHF 2 x 0,5 mm² 14 1 FUSIBLE LINK 4 C M S1 S2 S S4 S5 S 5 0 WHEN DAMPER IS NOT ENERIZED CONTACTS S1-S2, S4-S5 ARE CLOSED BELIMO BF24 BF20 BF120 BLF24 BLF20 IP 54 FDO - A0(A0) Fire Damper
5 FDO-EL WIRIN DIARAM with ExMax or RedMax actuator PE -EARTHIN RAIL x 0,5 mm² PE POWER SUPPLY 24-20V AC/DC L/+ N/- PE (PE) BK Y BN BK Y BN FUSIBLE LINK DAMPER DAMPER CLOSED OPEN 4 x 0,5 mm² x 0,5 mm² PE HEATER 5 5 WHEN DAMPER IS NOT ENERIZED CONTACTS S1-S2, S4-S ARE CLOSED ExMax-15-SF RedMax-15-SF IP FDO-EL WIRIN DIARAM with InMax actuator SIHF 2 x 0,5 mm² 14 1 FUSIBLE LINK 50/4/100 C DAMPER DAMPER CLOSED OPEN 4 PE 4 PE PE PE V AC/DC PE 1 14 ~ ~ x 0,5 mm² x 0,5 mm² PE HEATER WHEN DAMPER IS NOT ENERIZED CONTACTS S1-S2, S4-S ARE CLOSED InMax-15-SF IP VM09Y2015/Halton Marine reserves the right to alter products without notice. FDO-PNR PNEUMATIC DIARAM ON BOX SE A (2 C) 4/100 C 0 4 OPTION: LIMIT SWITCHES SPRIN RETURN ACTUATOR SPEED CONTROLLER QUICK EXHAUST VALVES PIPELINES:POLYAMIDE FUSIBLE LINK VALVE PORT/2 WAY OPTION: MANUAL VALVE PORT/2 WAY OPTION: SOLENOID VALVE PORT/2 WAY PRESSURE REULATOR PNEU. INLET (5 - BAR) FOR A PLASTIC TUBE Ø MM CLOSED OPEN /220 V 1. SPRIN RETURN VALVE 2. QUICK EXHAUST VALVE. SILENCER 4. FUSIBLE LINK VALVE 5. OPTION: SOLENOID VALVE. MALE CONNECTOR. DOUBLE NIPPLE. PLASTIC TUBE. OPTION: STAINLESS STEEL 9. OPTION: OPEN / CLOSED SWITCHES 10. OPTION: MANUAL VALVE 11. PRESSURE REULATOR 12. SPEED CONTROLLER VAC/DC (+)(-) PE ~ ~ FDO - A0(A0) Fire Damper CLOSED AND OPENED INFORMATION OUT JUNCTION BOX ION BOX 9
6 FDO - A0(A0) Fire Damper 10
products 22 º C Ventilation Air Conditioning Refrigeration Inside PROVIDED BY HEINEN & HOPMAN
products > Dampers HT OUTSIDE 35 C HUMIDITY 90% 22 º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration dampers HT There are different types of dampers: Fire and gas
More informationUTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper
Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,
More informationproducts 22 º C Ventilation Air Conditioning Refrigeration Inside PROVIDED BY HEINEN & HOPMAN
products > Dampers - SF OUTSIDE 35 C HUMIDITY 90% 22 º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration dampers Fire and smoke dampers Fire and smoke dampers prevent
More informationFDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts
Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings
More information7/S1 FIRE DAMPER PPZEN. v 2.5 (en)
7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...
More informationDSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes
DSA MATERIALS HIGH EFFICIENCY DROPLET SEPARATOR With heated vanes PART MATERIAL FINISHING Droplet separator Aluminium EN AW 6060 - Frame Aluminium EN AW 5754 Painted RAL9010, C5-M as standard* Frame Heating
More informationHML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating
HML Airflow Unit for Large Volumes with Centralized Airflow Heating Available as network compatible Halton HML is an airflow unit for large air volumes with centralized airflow heating. The unit can be
More information(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.
Fire damper pl-30 General characteristics Application Fire dampers prevent fire and smoke from spreading through ventilation ducts in buildings. The dampers are intended for use inside buildings and are
More informationFire Dampers. Types FKA FRL FRK 4/1/EN/1
Fire Dampers Types FKA FRL FRK /1/EN/1 Contents Description Description... Construction... Standard Sizes Installation Details... Functional Description Product Range... Accessories... Circuit Diagrams...
More informationNEW. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.
January 2008 A-60 Marine Fire Dampers Includes new casing depths and thickness, Atex rated motor and visual indication options. NEW A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore
More informationHMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins
HMR DUAL DUCT CABIN UNIT For passenger and crew cabins APPLICATIONS Halton HMR is pressure independent dual duct cabin unit. The airflow is continuously measured from the warm air spigot, as well as for
More informationDAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX
DAMPERS LSS - R LSS / SOD circular single blade shut off damper SSVent rectangular multiblade shut off damper S.Ventil R1OVL circular single blade weather tight damper/valve RD circular regulating damper
More informationPK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.
Systemair Fire Dampers for Explosive Areas Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S www.systemair.com Description Fire damper (hereafter referred to as damper) is a fire
More informationPART MATERIAL PART MATERIAL. Casing Hot galvanized steel / Option: stainless steel EN (AISI316L) Reheat coil EN 1.
HMF Single Duct Cabin Unit for Passenger And Crew Cabins Available as network compatible The Halton HMF is an automatic or semi-automatic single duct cabin unit with intergrated reheater. Automatic operation
More information7/S5 FIRE DAMPER FD40. v 2.9 (en)
7/S v.9 (en) FIRE DAMPER FD0 www.klimaoprema.hr 69 FIRE DAMPER - FDC TABLE OF CONTENTS FIRE DAMPER FD0 7 FIRE CLASSIFICATION 7 SELECTION DIAGRAM 7 ORDERING KEY 7 DAMPER MODELS 7 FD0-M rectangular fire
More informationCatef Marine-Fire. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.
Includes new casing depths and thickness, Atex rated motor and visual indication options. Features Blades 430 stainless steel and 316 stainless steel options. Casings Lightweight cost effective design.
More informationPTS - Single-Blade Damper. Halton PTS. Single-Blade Damper
Halton PTS Single-Blade Damper Shut-off, adjustment, balancing or control damper Casing leakage classification: EN 1751, Class C Casing and damper blade made of galvanised steel Tightness classification
More informationSmoke damper EKO-SRB1
Smoke damper EKO-SRB1 Description The EKO-SRB1 smoke damper is a CE-approved damper in fire class E60 intended for fire compartmentation or protection against the spread of fire and smoke in ventilation
More informationVAV TERMINAL BOXES TYPE: BA BT
Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500
More informationKWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology
KWT GALLEY WATER WASH HOOD With supply air and Capture Jet technology APPLICATIONS Halton KWT is a galley water wash hood for use in marine & offshore applications. The highly efficient KWT hood uses Halton
More informationFIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS
FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages
More informationHME SINGLE DUCT CABIN UNIT CABIN UNITS HME. Sound attenuator and balancing box
HME SINGLE DUCT CABIN UNIT Sound attenuator and balancing box MATERIALS APPLICATIONS Halton HME can be used for air distribution and sound attenuation in various applications such as suites and pantries.
More information7/S6 FIRE DAMPER FDC40. v 2.9 (en)
7/S6 v.9 (en) FIRE DAMPER FDC0 www.klimaoprema.hr 8 TABLE OF CONTENTS FIRE DAMPER FDC0 87 FIRE CLASSIFICATION 87 SELECTION DIAGRAM 88 ORDERING KEY 88 DAMPER MODELS 89 FDC0-M cylindrical fire damper with
More informationFire/smoke damper EKO-SRBG1
Fire/smoke damper EKO- Description The EKO- fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.
More informationFront panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option
ZSC - Halton Zen Semi-Circle Displacement ventilation unit Capacity for wide supply airflow range. Uniform supply air distribution is achieved through small perforations, providing optimal conditions in
More informationCasing Hot galvanised steel / Option: stainless steel EN (AISI316L) Reheat coil EN (AISI 304)
HME Single Duct Cabin Unit Sound Attenuator And Balancing Box Available as network compatible The Halton HME can be used for air distribution and sound attenuation in various applications such as suites
More informationCAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1
X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air
More informationNYBORG AS N-6230 SYKKYLVEN, NORWAY TEL FAX
NYBORG AS N-6230 SYKKYLVEN, NORWAY TEL +47 70 25 40 80 - FAX +47 70 25 29 08 office@nyborgfan.com - www.nyborgfan.com OPERATION AND MAINTENANCE NYBORG CIRCULAR FIRE DAMPER TYPE BSS 500-400 R-LD Version
More informationMarine Fire and Gas Dampers
M 3.2/2/EN/ 2 Marine Fire and Gas Dampers Type JFD Telephone + 6 06-678 8188 Telefax + 6 06-678 8288 / 388 E-mail enquiry@troxapo.com www.troxapo.com Contents Description Description 2 Accessories 6 Construction;
More informationCAV controllers Type RN
2.1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or return air in constant
More informationFire/smoke damper EKO-JBG2
Fire/smoke damper EKO-JBG2 Description The EKO-JBG2 fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.
More informationOPTIVENT Housing HVSA, HVSL
OPTIVENT Housing HVSA, HVSL Key features Variable air flow Constant air flow Real time air flow display with compact controller 227VM The HVSA and the HVSL are apartment-specific room ventilation regulators
More informationPKIR3G, PKIS, PKIS3G and PKIS3GA
PKIR3G, PKIS, PKIS3G and PKIS3GA Fire Dampers Fire resistance EI60S, EI90S and EI120S 1396 - CPR - 0076 1396 - CPR - 0077 1396 - CPD - 0062 Ordering codes Dimensions Type of activation PKIR3G 1) - ødn
More informationFire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.
Fire & Gas Introduction Fire & Gas are used in ventilation systems to prevent the spread of flame and/or smoke between divisions. Authority/Certification Wozair manufacture three types of Fire & Gas Damper
More informationBevent Rasch BSK Fire /04/2017
Bevent Rasch - Fire - BSK120 10/04/2017 Rectangular Fire resistance class /S Sizes from 200 x 200 mm to 1200 x 1000 mm Prefitted safety actuator 24V or 230V Available in MagiCAD CE-marked building product
More informationM A D E L. FOK-EIS-180 Fire dampers CE
M A D E L EN 60: FOK-EIS-80 Fire dampers CE The fire dampers FOK-EIS-80 work as a separator between two sectors of fire and ensure the same fire resistance that the structural elements of compartmentalisation,
More informationShut-off dampers. Type AKK. For contaminated air PD AKK 1
X X testregistrierung Shut-off dampers Type Variant with circular spigot For contaminated air Plastic circular shut-off dampers for shutting off aggressive media volume flows in air conditioning systems
More informationRVP-R- VAV controller. In explosion-proof version
VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units
More informationU X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)
Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The handling and installation
More informationETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE
FIRE SAFETY AIR MANAGEMENT FIRE DAMPERS ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE 2 ETPR-E-1 Fire damper Technical catalogue Fire and smoke damper ETPR-E-1 is used as a closing device for preventing the
More informationESAS Smoke control damper
ESAS Smoke control damper 1 Rectangular smoke control damper ESAS is specially designed to use in single fire compartment applications as a closing or as an opening damper for smoke extract purposes. ESAS
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1
X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationSystemair Fire Dampers
Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S www.systemair.com As standard, all fire dampers are designed and certified to comply with EI-S performance attributes. fire dampers
More informationShut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.
X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off
More informationActionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects
March 06 A-60 Marine Fire Dampers Tests and Approvals A60 Fire Rated. Lloyds Register of Shipping Approved. Marine Equipment Directive compliant. USCG Approved. Germanischer Lloyds Approved. American Bureau
More informationAttachments. Explosion-proof actuators. For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) 09/2017 DE/en
X X testregistrierung Attachments Limit switch Solenoid valve Pneumatic actuator Electric actuator For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) for Type
More informationCAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1
X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air
More informationCFSD Series. Product Description
COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke
More informationVOLUME CONTROL / REGULATING DAMPERS
VOLUME CONTROL / REGULATING S PRODUCT RANGE Model Range Includes A - Multi-Leaf. (Flanged - Rectangular Duct) B - Multi-Leaf. (Slip joint / Spigot - Rectangular Duct) C - Multi-Leaf. (Slip joint / Spigot
More informationBC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED
BC 4.3 Gas Tight Dampers GTD-GB40-B-E Table Of Contents S. No Description Page No 1 Gas Tight Damper with Electric Drive 1 2 Electric Drive - Details 2-3 3 Gas Tight Damper with Pneumatic Drive 4 4 Pneumatic
More informationCRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic
Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS Perforated damper blade for better damper characteristic Manually adjustable blade (standard) Provision for motorised regulation Quick connection
More information3/2-way Solenoid Valve for pneumatics
656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511
More informationSafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )
( Flange Type ) SPK 30-100 Standard Construction FRAME: 160mm x 30mm x 1.5mm (16 Ga.) galvanized steel formed channel for flange connection. BLADES: 250mm max. width, 1.5mm (16 Ga.) galvanized steel. FINISH:
More informationFSD60/MFSD60 Multi-blade Fire Damper
DAMPER FSD60/MFSD60 Multi-blade Fire Damper Tested and conform to Tested and conform to BS476:Part20:1987 The ASLI Multi-Blade Fire Dampers have been developed to provide the versatility required for today
More informationseries FSD-FLD Fire and smoke dampers UL Approval
series FSD-FLD Fire and smoke dampers UL Approval www.koolair.com Series FSD-FLD 1 Fire and smoke dampers UL Approval FSD-B-U / FSD-A-U and FLD-S-U / FLD-S-UD CONTENTS Description FSD-B-U / FSD-A-U 2 Construction
More informationRegulation and shut-off damper SPB and SPC
SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are
More informationFIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006
FIREGARD Curtain Fire Dampers DAMPERS SFB (.) X UDC. AUGUST 00 FEATURES Galvanised or Stainless Steel Interlocking Blades in Airtight Casing. Stainless Steel Side Seals. Constant Tension Stainless Steel
More informationA-60 Marine Fire Damper
Catalogue A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects Suitable for applications in A0, A15, A30 and A60 class bulkheads and decks www.actionair.co.uk sales@actionair.co.uk
More informationMotorized Fire Dampers
Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and
More informationFire/combustion gas damper EKO-JBG
Fire/combustion EKO-JBG Description The EKO-JBG fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting.
More informationElectrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)
Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Order code MF-04-510-HN-442 Series and function (plug pins on top, see pictures) 441 = 12 V DC without plug socket 442 =
More informationFire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3
SA/6/1/EN/3 Fire Dampers Type FDF Compliant to SABS (193:2004) TROX (South Africa) (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax. +27 (0)33 398 1100 email : pmb@troxsa.co.za
More informationCAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)
X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered
More informationHFB - Airflow Management Damper. Halton HFB. Airflow Management Damper
Halton HFB Airflow Management Damper Control damper for different airflow and duct pressure control applications Pressure-independent operation Galvanised steel design Circular duct connection equipped
More informationSMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS
SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00
More informationVAV terminal units. Type TVM. For dual duct systems PD TVM 1
X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings
More informationACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans
Hacer título más resumido ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans Construction Casing The fan casings are manufactured from heavy gauge galvanised sheet steel and
More informationVariable Air Volume Dampers
OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control
More informationVolume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating
Volume Control Dampers Incorporating Series LF upvc-vcd 2.76 m 3 /hr/m 2 leakage at 50 Pa, over 70% better than required by Part L of Building Regulations Corrosion resistant, perfect for chlorinated atmospheres
More informationType AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)
Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off
More informationValve series KN-05 acc. to NAMUR, 3/2-way G1/4 780 Nl/min (0.792 Cv)
Valve series KN-05 acc. to NAMUR, 3/2-way G1/4 780 Nl/min (0.792 Cv) Order code Series and function 1) Plug socket see page 5.042. KN-05-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationShutter Fire Damper Type FSD GFSD 4/1.1/B/1
Shutter Fire Damper Type FSD GFSD /./B/ Contents Description Description... Construction... Installation Details... Control Accessories... Technical Data... Order Details... 7 8 9 FSD-L GFSD-L FSD Fire
More informationU X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)
CODIFICATION CONSTRUCTION Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The
More informationVolume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper
Volume Control Dampers Incorporating Series HVC-VCD Excellent general purpose volume control damper Lightweight aluminium construction Fully protected linkage system positioned outside of airstream Very
More informationParticle Filter Box FKU
Particle Filter Box FKU Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationFIREGARD GILBERTS. Curtain Fire Dampers FEATURES
FIREGARD Curtain Fire Dampers DAMPERS SFB (.) X UDC. FEBRUARY 00 FEATURES Galvanised or Stainless Steel Interlocking Blades in Airtight Casing. Optional Stainless Steel Side Seals. Constant Tension Stainless
More informationCAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1
X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered
More informationHFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories
HFB Airflow Management Damper Control damper for different airflow and duct pressure control applications Pressure-independent operation Galvanised steel design Circular duct connection equipped with integrated
More informationNSDZ. Swirl diffusers with adjustable air control blades
Swirl diffusers with adjustable air control blades NSDZ The diffusers NSDZ are intended to use in low- and medium-pressure ventilation systems. They allow for obtaining the swirl air flow and are especially
More informationFire damper ETPR. Specifications. Product code example Fire damper ETPR
Fire damper ETPR ETPR fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 1366-2. ETPR meets the requirements of fire class EI 60 S / EI 90 S.
More informationVAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K
. X X testregistrierung VAV terminal units Type Easy controller Compact controller Circular connection on the fan end For extract air systems with demanding acoustic requi rements VAV terminal units for
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting K
.1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationBlade Features. AirShield Control and Shut Off Dampers. AirShield
April 2011 AirShield AirShield AirShield Aerofoil Air Control Dampers AirShield Aeroseal Air Control and Shut Off Dampers AirShield Features and Design Guide Opposed blade dampers suitable for systems
More informationFor installation into ductwork
X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum
More informationShort casing. Long casing (L version) Commercial premises
CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled
More informationCombustion gas damper EKO-SRB
Combustion EKO-SRB Description The EKO-SRB combustion is a Class E60 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment
More informationSlot diffusers, Round duct diffusers. IMP Klima
, Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING
More informationType KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU
Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of
More information3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics
654 3/-way and x 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Fast response times Space saving ( x 3/-way version) Type 654 can be combined with...
More informationFire/combustion gas damper EKO-JBL
Fire/combustion Description The fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting. The damper is designed
More informationCombustion gas damper EKO-JB
EKO-JB Description The EKO-JB combustion is a Class E6 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment wall or floor
More informationVKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.
VKAP 3. Features Power supply Temperature range Diameter - 1 mm to 315 mm; Airflow up to 137 m 3 /h; Easily mounted in any position; Backward-curved impeller; Low ambient temperatures; Cost-effective.
More informationNOVENCO FAN CATALOGUE
NOVENCO FAN CATALOGUE WWW.NOVENCO-MARINE.COM ZERAX AXIAL FLOW FANS PRODUCT The Novenco ZerAx series of axial flow fans use innovative design to reduce power consumption and to better fan efficiency. The
More informationSpecification. Introduction. A-60 Marine Fire Damper
March 2015 YY denotes last two digits of year that Wheelmark is affixed to damper A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects. Suitable for applications in A0, A15, A30,
More informationIncorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers
Incorporating V2.0 Product spec >>> > Series DJ - Drum jet diffusers Diffusers Drum jets (Premium) Recommended for: Wall, ceiling & duct Supply Overview Exceptional throw Throw completely adjustable Drum
More informationAir distribution product
Air distribution product The company C.L.A. was established in 1975 as a manufacturer company of air conditioning system components. Among its customers: dealers, air handling units producers and fans
More informationSystemair Fire Dampers
Fire safety products 1 / 7 Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S 1396 - CPD - 0061 1396 - CPD - 0062 Ordering codes Ordering Codes for Circular FD: Fire resistance class
More informationVARYCONTROL VAV Dual Duct Terminal Boxes
5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk
More informationCRP. Commissioning damper, Ductwork Leakage Class 0
Commissioning damper, Ductwork Leakage Class 0 Quick facts Perforated damper blade for better damper characteristic Manually adjustable blade (standard) Motorised regulation Provision for motorised regulation
More information