Fire Safety Products. Product Overview

Size: px
Start display at page:

Download "Fire Safety Products. Product Overview"

Transcription

1 Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Fire Safety Products Product Overview

2 SAFETY PRODUCTS prevent the spread of toxic gases, smoke and fire, help with evacuation, increase the effectivness of active fire protection systems and minimize the property damage. MULTI-COMPARTMENT SMOKE EVACUATION MULTI-COMPARTMENT SMOKE AIR GRILLE EVACUATION

3 S Safety position: closed PKIR3G PKIS3G Circular Fire Damper DN 100 up to 1000 W H = up to CPR-0077 PKIR-E60S PKIS3GA Circular Fire Damper DN 100 up to CPD < W 1200 & 100 H CPR-0077 PKI-C PKIS-S Cartridge Fire Damper DN 100 up to CPD-0050 W > 1200 and/or H > 800 up to CPD-0062 PKIS-S W > 1200 and/or H > 800 up to CPD-0062 * Detailed information about fire resistivity is on the back page.

4 SMOKE S Safety position: open or closed DKIS1 Single-compartment Rectangular Smoke Damper W H = up to DKIR1 Single-compartment Circular Smoke Damper DN 100 up to CPR CPD-0058 DKISMA Multi-compartment Smoke Damper W H = up to CPR-0112 EKIR-E60S Circular Evacuation Damper DN 100 up to 630 EVACUATION S Safety position: open 1396-CPD-0069 FGS Fire Air Grille AIR GRILLES Safety position: closed * Detailed information about fire resistivity is on the back page.

5 Product type Dimensions range (mm) Fire resistivity Supporting construction Installation - tested at underpressure (Pa) Wet Dry Soft crossing Instal. kit On a wall Out of a wall ve W 300 W 100 DN 400 ve W 300 W ve ve W 300 W PKIR3G 400 < DN 630 ve ve ve < DN 1000 ve ve 500 PKIR-E60S DN 100 up to 630 PKI-C DN 100 up to 200 E60 ve 300 NOINS 300 NOINS ho 300 NOINS 300 NOINS ve ho 300 ve ho 300 ve ho 300 ve KIT 300 W, P 300 W, P PKIS3G up to ve KIT 300 W, P 300 W, P ve KIT 300i o W, P 300i o W, P 300 PKIS3GA 800 < W 1200 & 100 H 300 ve P 300 P ho ve P 300 P ho PKIS-S MULTI, PKIS-S W > 1200 and/or H > 800 up to ve W 300 W ho ve 300 ho FGS S a, S a * ve S a = 33 m 3 / (hm 2 ) at 50 Pa S a = 33 m 3 / (hm 2 ) at 50 Pa DKIR1 DN 100 up to 630 E (v ed i o) S500 C AA single ve 500 DKIS E (v ed i o) S1500 C AA single ** ve 500 & 1500 ** DKISMA (v ew i o) S1500 C mod AA multi ve 1500 EKIR-E60S DN 100 up to 630 E60 ve 300 NOINS 300 NOINS ho 300 NOINS 300 NOINS

6 Legend RIGID/FLEXIBLE WALL ONLY RIGID WALL/CEILING ONLY IN/ON THE DUCT MULTI KIT All fire dampers are designed for explosion hazardous areas classified as Multi-installation in a wall: multiple neighbouring dampers always aligned horizontally and/or vertically with blade axis in horizontal orientation Up to dimensions W H = mm only * The FGS has resistivity S a in the upper part & S a in the lower part of a vertical building element according to ETAG 026 Part 4 art par. 6 ** DKIS1 has resistivity E (v ed i o)s500 C AA single, for dimensions bigger than W H = mm P W NOINS Installation on a wall or out of a wall with Promatect boards insulation for lower ceilings with resistivity EI30/45/60/90S; all PKIS3G and PKIS3GA up to dimensions W H = mm only Installation on a wall or out of a wall with mineral wool insulation, installation with S up to DN = 400 mm, installation with S up to DN = 500 mm Installation on a wall or out of a wall without insulation The tightness of the blade and the casing according to EN 1751: - 3C for PKIR3G as standard - 2C for other fire damper types as standard - 3C for other fire damper types for extra charge Modulated fire dampers (the activation mechanism DV9-T-SR) are manufactured: - PKIR3G with DN 160 mm - PKIR-E60S in all dimensions - PKIS3G with H 160 mm E8283. IMOS-Systemair. Maart 2018 GOOD TO KNOW Current information on all fire safety products are available at

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8. Fire safety products 1 / 8 DKISMA Systemair multicompartment rectangular smoke control dampers Resistance class EI120(v ew i o) S1500C mod AAmulti 1396 - CPR - 0112 Ordering codes Nominal dimensions Type

More information

PKIR3G, PKIS, PKIS3G and PKIS3GA

PKIR3G, PKIS, PKIS3G and PKIS3GA PKIR3G, PKIS, PKIS3G and PKIS3GA Fire Dampers Fire resistance EI60S, EI90S and EI120S 1396 - CPR - 0076 1396 - CPR - 0077 1396 - CPD - 0062 Ordering codes Dimensions Type of activation PKIR3G 1) - ødn

More information

Systemair Fire Dampers

Systemair Fire Dampers Fire safety products 1 / 7 Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S 1396 - CPD - 0061 1396 - CPD - 0062 Ordering codes Ordering Codes for Circular FD: Fire resistance class

More information

SMOKE CONTROL DAMPERS

SMOKE CONTROL DAMPERS SMOKE CONTROL DAMPERS 96 - CPD - 0058 Round DKIR and Rectangular DKIS ORIGINAL INSTALLATION, OPERATION AND MAINTENANCE MANUAL EVERY SMOKE DAMPER NEEDS TO BE INSTALLED IN ACCORDANCE WITH THIS MANUAL! /

More information

PKI-C Cartridge Fire Dampers

PKI-C Cartridge Fire Dampers Fire Safety Products / 7 PKI-C Cartridge Fire Dampers Fire resistance class EI60S, EI90S and EI0S 96 - CPD - 000 Ordering codes Fire resistance class PKI-C-EI - 60S, 90S and 0S Codes section. The thermal

More information

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA 96 - CPR - 0 ORIGINAL INSTALLATION, MAINTENANCE AND OPERATION MANUAL EVERY SMOKE DAMPER NEEDS TO BE INSTALLED IN ACCORDANCE WITH THIS MANUAL! / PP-5_0604 DKISMA

More information

Systemair Fire Dampers

Systemair Fire Dampers Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S www.systemair.com As standard, all fire dampers are designed and certified to comply with EI-S performance attributes. fire dampers

More information

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

Fire damper ETPR. Specifications. Product code example Fire damper ETPR Fire damper ETPR ETPR fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 1366-2. ETPR meets the requirements of fire class EI 60 S / EI 90 S.

More information

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas. Systemair Fire Dampers for Explosive Areas Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S www.systemair.com Description Fire damper (hereafter referred to as damper) is a fire

More information

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm. Fire damper pl-30 General characteristics Application Fire dampers prevent fire and smoke from spreading through ventilation ducts in buildings. The dampers are intended for use inside buildings and are

More information

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

7/S1 FIRE DAMPER PPZEN. v 2.5 (en) 7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...

More information

Bevent Rasch BSK6. - Fire /04/2017

Bevent Rasch BSK6. - Fire /04/2017 Bevent Rasch - Fire - BSK6 11/04/2017 Fire resistance class EI60 / EI60S Sizes from 200 x 200 mm to 800 x 800 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product

More information

Bevent Rasch BSK Fire /04/2017

Bevent Rasch BSK Fire /04/2017 Bevent Rasch - Fire - BSK120 10/04/2017 Rectangular Fire resistance class /S Sizes from 200 x 200 mm to 1200 x 1000 mm Prefitted safety actuator 24V or 230V Available in MagiCAD CE-marked building product

More information

Fire dampers ETCE and ETCS TECHNICAL DATA

Fire dampers ETCE and ETCS TECHNICAL DATA Fire dampers ETCE and ETCS TECHNICAL DATA 2 Fire dampers ETCE and ETCS Veloduct ETCE fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 13662.

More information

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings

More information

7/S5 FIRE DAMPER FD40. v 2.9 (en)

7/S5 FIRE DAMPER FD40. v 2.9 (en) 7/S v.9 (en) FIRE DAMPER FD0 www.klimaoprema.hr 69 FIRE DAMPER - FDC TABLE OF CONTENTS FIRE DAMPER FD0 7 FIRE CLASSIFICATION 7 SELECTION DIAGRAM 7 ORDERING KEY 7 DAMPER MODELS 7 FD0-M rectangular fire

More information

ESAS Smoke control damper

ESAS Smoke control damper ESAS Smoke control damper 1 Rectangular smoke control damper ESAS is specially designed to use in single fire compartment applications as a closing or as an opening damper for smoke extract purposes. ESAS

More information

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR MANAGEMENT FIRE DAMPERS ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE 2 ETPR-E-1 Fire damper Technical catalogue Fire and smoke damper ETPR-E-1 is used as a closing device for preventing the

More information

Smoke damper EKO-SRB1

Smoke damper EKO-SRB1 Smoke damper EKO-SRB1 Description The EKO-SRB1 smoke damper is a CE-approved damper in fire class E60 intended for fire compartmentation or protection against the spread of fire and smoke in ventilation

More information

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB Valid from //06 EN 5650:00-09 FIRE DAMPER FDMB These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMB. It is valid for production, designing,

More information

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages

More information

Rectangular fire damper TFER 30. pag. C-10

Rectangular fire damper TFER 30. pag. C-10 pag. C-10 Description Rectangular fire damper with CE label in conformity to UNI-EN 15650, certified according to EN 1366-2, classified EI 120 S in accordance to EN 13501-3. Removable shifted kinematic

More information

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

DVAX-ARS. Roof-mounted unit for mechanical smoke extract Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans DVAX- Roof-mounted unit for mechanical smoke extract 2 DVAX DVAX- Roof-mounted axial fan unit

More information

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD TPM 075/09-DK VALID FROM: 15/1/2012 I. CONTENT These technical specifications state a row of manufactured sizes and models of fire dampers and fire dampers

More information

TYPE EK-EU SMOKE CONTROL DAMPER

TYPE EK-EU SMOKE CONTROL DAMPER Homepage > PRODUCTS > Fire and Smoke Protection > Smoke Control Damper > Type EK-EU TYPE EK-EU SMOKE CONTROL DAMPER WITH TROXNETCOM AS AN OPTION CE COMPLIANT ACCORDING TO EUROPEAN REGULATIONS EK-EU WITH

More information

Fire/smoke damper EKO-SRBG1

Fire/smoke damper EKO-SRBG1 Fire/smoke damper EKO- Description The EKO- fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.

More information

series CEVH Smoke Evacuation Damper

series CEVH Smoke Evacuation Damper series CEVH Smoke Evacuation Damper www.koolair.com Series CEVH 1 CONTENTS Description 2 Dimensions 4 Installation 5 Assembly 6 Electrical connections 7 Technical data 8 Coding 10 2 Series CEVH Description

More information

Fire/smoke damper EKO-JBG2

Fire/smoke damper EKO-JBG2 Fire/smoke damper EKO-JBG2 Description The EKO-JBG2 fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.

More information

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

7/S6 FIRE DAMPER FDC40. v 2.9 (en) 7/S6 v.9 (en) FIRE DAMPER FDC0 www.klimaoprema.hr 8 TABLE OF CONTENTS FIRE DAMPER FDC0 87 FIRE CLASSIFICATION 87 SELECTION DIAGRAM 88 ORDERING KEY 88 DAMPER MODELS 89 FDC0-M cylindrical fire damper with

More information

Combustion gas damper EKO-JB

Combustion gas damper EKO-JB EKO-JB Description The EKO-JB combustion is a Class E6 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment wall or floor

More information

M A D E L. FOK-EIS-180 Fire dampers CE

M A D E L. FOK-EIS-180 Fire dampers CE M A D E L EN 60: FOK-EIS-80 Fire dampers CE The fire dampers FOK-EIS-80 work as a separator between two sectors of fire and ensure the same fire resistance that the structural elements of compartmentalisation,

More information

Fire Dampers Catalogue

Fire Dampers Catalogue Fire s Catalogue DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval UL 555 Classified 2013 For Use in Static & Dynamic Systems 3 Hour Rating Made in

More information

VX-6V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of

VX-6V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of SMOKE CONTRO in libraries of EI 1 (v o) S 1500a ed i AA multi EN 166-10:11 EN 12101-8:11 Certificate of Constancy of erformance 1812-CR-.../15 1060 FUNCTION The smoke control dampers are designed for smoke

More information

Rectangular smoke damper (remote controlled)

Rectangular smoke damper (remote controlled) Clapets coupe-feu et Volets de désenfumage D.A.S. Organisme Certificateur AFNOR Certification - www.marque-nf.com VU10 Rectangular smoke damper (remote controlled) Rf-Technologies nv - Lange Ambachtstraat

More information

Combustion gas damper EKO-SRB

Combustion gas damper EKO-SRB Combustion EKO-SRB Description The EKO-SRB combustion is a Class E60 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment

More information

lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction

lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction Duct and fittings Content Duct and fittings Introduction...3

More information

Fire damper FK120/FK90 TECHNICAL DATA

Fire damper FK120/FK90 TECHNICAL DATA Fire damper FK120/FK90 TECHNICAL DATA 2 Fire damper FK120/FK90 Figure 1 ER1 Figure 2 ER3 The rectangular fire damper FK120/FK90 is available both as motorized and with fuse. The damper casing is manufactured

More information

table of contents PRODUCT SUMMARY 2

table of contents PRODUCT SUMMARY 2 P R O D U C T C A T A L O G introduction Aire Technologies, Inc. is proud to present our line of air management and life safety products for integration into your HVAC system design, fabrication, or installation.

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

Air distribution product

Air distribution product Air distribution product The company C.L.A. was established in 1975 as a manufacturer company of air conditioning system components. Among its customers: dealers, air handling units producers and fans

More information

Fiberseal. Flexible fire protection closures. Fiberseal Evolution-Sm Fiberseal Evolution-Sa Fiberseal-H Fiberseal-S

Fiberseal. Flexible fire protection closures. Fiberseal Evolution-Sm Fiberseal Evolution-Sa Fiberseal-H Fiberseal-S Fiberseal Flexible fire protection closures Fiberseal Evolution-Sm Fiberseal Evolution-Sa Fiberseal-H Fiberseal-S Protection concepts 1. For openings in walls How can large openings in walls be sealed

More information

Rectangular smoke damper (remote controlled)

Rectangular smoke damper (remote controlled) NF-Clapets coupe-feu et Volets de désenfumage D.A.. NF 264 www.marque-nf.com VU120 Rectangular smoke damper (remote controlled) Rf-Technologies nv - Lange Ambachtstraat 40-9860 Oosterzele - Belgique -

More information

ACCESSORIES FOR DUCT FANS

ACCESSORIES FOR DUCT FANS FOR DUCT FANS Duct fan Clamp Filter box Silencer Electric heater Duct fans are mostly used in low-to medium-pressure ducted systems with additional components such as heaters, filter boxes, dampers, etc.

More information

VU120. Rectangular smoke evacuation damper. V22-EN-G 08/2017

VU120. Rectangular smoke evacuation damper.  V22-EN-G 08/2017 Organisme Certificateur AFNOR Certification - www.marque-nf.com VU120 Rectangular smoke evacuation damper. en 0749 Clapets coupe-feu et Volets de désenfumage D.A.S. Rf-Technologies nv Lange Ambachtstraat

More information

Fire Damper BSK-RPR. with general building supervisory approval Z

Fire Damper BSK-RPR. with general building supervisory approval Z Fire Damper BSK-RPR with general building supervisory approval Z-41.3-681 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de

More information

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available: Model ABV Tag: Project: Location: Date: Engineer: Contractor: Architect: Submitted by: Application: The ABV Automatic maintains a constant airflow volume in HVAC applications. The highly engineered damper

More information

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the

More information

Air Zone. High Care. Cleanroom Filtration

Air Zone. High Care. Cleanroom Filtration Air Zone igh Care Cleanroom Filtration Cleanroom filtration Clean and sterile air in a cleanroom zone is provided by absolute filters. If even greater safety in terms of sterility is required, behind the

More information

The VX-6 smoke control dampers are designed for smoke control systems in buildings outfitted with a one-stage

The VX-6 smoke control dampers are designed for smoke control systems in buildings outfitted with a one-stage OE CONTROL in libraries of EI 1 (v ew h owi o) 1 C 0 multi EN 66: EN 1218: Certificate of Constancy of Performance 1CPR03/ Damper tightness class: 4 Casing tightness class: C EN51:2 FUNCTION The smoke

More information

Type VSD35. Nominal length up to 1500 mm: one spigot

Type VSD35. Nominal length up to 1500 mm: one spigot Type VSD35 Nominal length up to 1500 mm: one spigot NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with 35 mm diffuser face (nominal width) and adjustable air control elements

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

Cleanroom Filtration

Cleanroom Filtration Cleanroom Filtration Cleanroom filtration Clean and sterile air in a cleanroom zone is provided by absolute filters. If even greater safety in terms of sterility is required, behind the absolute filter

More information

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION air handling intelligence FIRE SFETY Fire Damper in libraries of EI 10 (v e -i o) S EN 13501-3+1:01 EN 15650:0 Certificate of Conformity 1488-CPD-081/W EUROPEN PTENT PPLICTION EP 01158318 GOLD MEDL MTP

More information

Slot diffusers for ceiling installation

Slot diffusers for ceiling installation X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger

More information

Volume Flow Limiters Type VFL

Volume Flow Limiters Type VFL X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered

More information

PERFORMANCE SPECIFICATIONS SINGLE-SPEED, 110 CFM VENTILATION FAN

PERFORMANCE SPECIFICATIONS SINGLE-SPEED, 110 CFM VENTILATION FAN PERFORMANCE SPECIFICATIONS SINGLE-SPEED, 110 CFM VENTILATION FAN HVI PERFORMANCE ELECTRICAL & WEIGHT 6" Duct 0.1 Ps - Static Pressure (inh2o) 0.25 Ps Sound (Sones) Power (Watts) Efficacy (CFM/Watt) Volts

More information

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of FIRE SAFETY Fire Valve in libraries of EI 60 (v e -o i) S EN 131-3+A1:10 EN 156:10 Certificate of Conformity 1488-CPD-02 82/W FUNCTION The fire valves are designed for buildings where in the event of a

More information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular

More information

Slot diffusers, Round duct diffusers. IMP Klima

Slot diffusers, Round duct diffusers. IMP Klima , Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING

More information

LOUVERED FACE GRILLES AND REGISTERS

LOUVERED FACE GRILLES AND REGISTERS Performance Notes for Supply rilles and Registers, 6 and 67 Series Throw, Spread and Drop The isovel diagrams shown below, illustrate in plan view, the relationship of horizontal spread to throw for three

More information

SMOKE EXTRACTION VENTILATION FOR PARKING PREMISES

SMOKE EXTRACTION VENTILATION FOR PARKING PREMISES SMOKE EXTRACTION VENTILATION FOR PARKING PREMISES 08 CONTENTS Smoke extraction systems page 4 JAF axial jet fans page 6 ICF impulse centrifugal fans page 0 Ventilation system for underroof parking page

More information

Cleanroom Filtration

Cleanroom Filtration Cleanroom Filtration Cleanroom filtration Clean and sterile air in a cleanroom zone is provided by absolute filters. If even greater safety in terms of sterility is required, behind the absolute filter

More information

Mechanical mixing box MBM

Mechanical mixing box MBM Mechanical mixing box MBM Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...

More information

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 Installation dimensions AS/GS120 AS/GS130 Application The grille type AS / GS is used for the supply and exhaust of cooled or heated air in facilities

More information

Directive ErP 125 and Fans by Systemair

Directive ErP 125 and Fans by Systemair Fans Air Handling Units Air Distribution Products Fire safety Air Curtains and Heating Products Tunnel Fans Directive and Fans by Systemair 2 Directive Directive 3 Systemair fans and Directive Globally

More information

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance 07/2013 Fläkt Woods FIFLO EN 2013.07 2 ZU CLOSED AUF OPEN Fire damper ETPS-EI Contents Operation and Maintenance

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES 49-240 48LL1 49-280 49-480 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance. Linear bar grilles offer a choice

More information

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise Halton AWE/AWU Universal Grille Horizontal air supply, suitable also for exhaust Fixed front vanes, stable throw pattern with vertical 15 deflection: AWE, no deflection: AWU Adjustable rear vanes for horizontal

More information

Fire/combustion gas damper EKO-JBL

Fire/combustion gas damper EKO-JBL Fire/combustion Description The fire/combustion is a typeapproved damper intended for fire isolation or as protection against the spread of flame and fire gases in ventilation ducting. The damper is designed

More information

Motorized Fire Dampers

Motorized Fire Dampers Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

TECHNICAL-OPERATIONAL DOCUMENTATION. FIRE SAFETY VALVES type V370 and RK370

TECHNICAL-OPERATIONAL DOCUMENTATION. FIRE SAFETY VALVES type V370 and RK370 TECHNICAL-OPERATIONAL DOCUMENTATION FIRE SAFETY VALVES type V370 and RK370 MANUFACTURER: FRAPOL Spółka z o.o. 30-832 Kraków, ul. Mierzeja Wiślana 8 Phone: (012) 653-27-66, 653-27-67, 653-26-92 fax (012)

More information

CONSTANTFLOW Volume Flow Controllers

CONSTANTFLOW Volume Flow Controllers 5/9.1/EN/8 CONSTANTFLOW Volume Flow Controllers for constant volume systems Type EN The art of handling air Contents Description Description 2 Application 3 Construction Dimensions Accessories 4 Dimensions

More information

WhispAire Range Hood Quiet Hood

WhispAire Range Hood Quiet Hood INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS WhispAire Range Hood Quiet Hood IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF FIRE, ELEC- TRIC SHOCK, OR INJURY TO PERSONS, OBSERVE

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers Incorporating V2.0 Product spec >>> > Series DJ - Drum jet diffusers Diffusers Drum jets (Premium) Recommended for: Wall, ceiling & duct Supply Overview Exceptional throw Throw completely adjustable Drum

More information

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers AMCA International Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. The International

More information

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER MODEL CWD MODEL FEATURES Exhaust air up to 3,360 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air 5/9.2/EN/6 Volume Flow Limiter Type VFL for insertion into air ducting The art of handling air Contents Description 3 Dimensions 3 Nomenclature 4 Technical data 4 Acoustic data 4 Installation notes 5 Order

More information

Smoke control damper RKI-90 Test certificate Z

Smoke control damper RKI-90 Test certificate Z Resistance class EK90 within smoke extraction ducts that have a fire resistance time of 90 min Ordering example / dimensions smoke control damper consisting of the housing with cut-off damper designed

More information

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75. Alsident System 100. Chemical Resistant (CR) Product Information SYSTEM 100 CR

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75. Alsident System 100. Chemical Resistant (CR) Product Information SYSTEM 100 CR Alsident System 100 Chemical Resistant (CR) Product Information System 100 Chemical Resistant (CR) General Information Product Specification Product Description System 100 Chemical Resistant (CR) Alsident

More information

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw Water terminals from 91 to 1548 m 3 /h SysCoil Comfort Floor and ceiling fan coil units from 0,5 to 9,6 kw from 0,6 to 13,6 kw SysCoil Comfort Innovation for an optimum comfort ErP 2018 TERTIAIRY H 3 /h

More information

VU120. Rectangular smoke evacuation damper. V22-F 07/2015

VU120. Rectangular smoke evacuation damper.   V22-F 07/2015 Organisme Certificateur AFNOR Certification - www.marque-nf.com VU120 Rectangular smoke evacuation damper. en Clapets coupe-feu et Volets de désenfumage D.A.S. Rf-Technologies nv Lange Ambachtstraat 40

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

Linear Floor Grilles Models FG, F20, F25 and FRO

Linear Floor Grilles Models FG, F20, F25 and FRO April 2010 Linear Floor Grilles Linear Floor Grilles Models FG, F20, F25 and FRO Features Model FG Recessed Linear Floor Grille Model F20 and F25 Flanged Linear Floor Grille Model FRO Roll Out Floor Grille

More information

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h SOUND-INSULATED KITCHEN FAN Series device. The impeller is mounted on the motor shaft and is balanced statically and dynamically. The motor has F class motor winding insulation and ingress protection rating.

More information

4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en)

4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en) 4/S6 v 2.5 (en) VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T www.klimaoprema.hr 253 TABLE OF CONTENTS Variable air volume control damper - round... 255 Variable air volume control damper - rectangular...

More information

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN Fire damper BKA-EN with general technical approval Z-41.3-667 tested according to DIN EN 1366-2 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Phone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980

More information

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of

More information

High Performance Axial Fans

High Performance Axial Fans High Performance Axial Fans Model RA Standard and High Temperature High Efficiencies Low Sound January 2014 High Performance Axial Fans Greenheck s model RA, high performance, direct-driven axial fans,

More information

Fire Block and Pressed Steel Grilles

Fire Block and Pressed Steel Grilles September 2010 Fire Block and Pressed Steel Grilles Fire Block FB60 Sodium silicate based intumescent material. Provides the lowest activation temperature of any intumescent material at degrees C. It is

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1 Shutter Fire Damper Type FSD GFSD /./B/ Contents Description Description... Construction... Installation Details... Control Accessories... Technical Data... Order Details... 7 8 9 FSD-L GFSD-L FSD Fire

More information

Regulation and shut-off damper SPB and SPC

Regulation and shut-off damper SPB and SPC SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are

More information

Air Transfer Grilles. NS Core only grille for beading in place. NSNL Core only No-Sight

Air Transfer Grilles. NS Core only grille for beading in place. NSNL Core only No-Sight Air Transfer Grilles NS Core only grille for beading in place NSNL Core only No-Sight Grilles 2 Air Transfer Grilles NS / DV / NSNL Introduction Waterloo transfer grilles are suitable for mounting in doors,

More information

Adjustable Duct Grilles

Adjustable Duct Grilles Adjustable Duct Grilles 1RV Single vertical set of blades 2RV One set vertical, one set of horizontal blades Adjustable Duct Grilles 1RV / 2RV Introduction the side of an exposed circular duct without

More information

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, aluminium construction Circular silencers, in rigid aluminium construction, for the reduction of noise in the

More information

IMP Klima. Swirl diffusers. Variable swirl diffusers

IMP Klima. Swirl diffusers. Variable swirl diffusers Swirl diffusers Variable swirl diffusers OD-4 OD-, OD-V OD-7 OD-7 OD-9 OD-5 OD-4 KD-8 OD-8 OD-5 Dn Dz Dn Dz A x A φ A 84 4 295x295 00 0.045 92 50 95x95 0 0.00 50 450 495x495 500 0.086 70 5 595x595 600

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

HIGH-POWERED VENTILATORS

HIGH-POWERED VENTILATORS HIGH-POWERED VENTILATORS WITH ROOF FANS 400ºC/2h The THT/HATCH series was designed using high-powered ventilator technology for smoke extraction in the event of a fire, and is equipped with THT series

More information