TECHNICAL-OPERATIONAL DOCUMENTATION. FIRE SAFETY VALVES type V370 and RK370

Size: px
Start display at page:

Download "TECHNICAL-OPERATIONAL DOCUMENTATION. FIRE SAFETY VALVES type V370 and RK370"

Transcription

1 TECHNICAL-OPERATIONAL DOCUMENTATION FIRE SAFETY VALVES type V370 and RK370 MANUFACTURER: FRAPOL Spółka z o.o Kraków, ul. Mierzeja Wiślana 8 Phone: (012) , , fax (012) MARCH 2013

2 List of contents 1. INTRODUCTION GENERAL CHARACTERISTICS VERSIONS PRINCIPLES FOR INSTALLATION OF FIRE VALVES PRINCIPLES FOR FIRE VALVES MAINTENANCE PERIODICAL MAINTENANCE LIST OF SPARE PARTS TECHNICAL DATA OF ACTUATORS AND SOLENOIDS FIRE VALVE INSPECTION DOCUMENT... 20

3 1. INTRODUCTION Rectangular V370 and round RK 370 fire safety valves with fire resistance class EI 120 (ve i o) S are manufactured by FRAPOL Sp. z o.o. in Krakow and are intended for use in the construction industry as elements closing ventilation ducts during the fire within vertical fire barrier to prevent permeation of hot gases and fire smokes via this way to zones not covered by the fire. The fire safety valves feature: EC Certificate of Conformity No CPD-0352/W EC Certificate of Conformity No CPD-0353/W Issued by: Building Research Institute Warszawa, ul. Filtrowa 1 For conformity with harmonised European standard: PN-EN 15650:2010 Ventilation for buildings. Fire dampers They also feature: Hygienic Attestation HK/B/1539/01/2012 issued by: National Institute of Public Health National Institute of Hygiene Warszawa, ul. Chocimska GENERAL CHARACTERISTICS V370 and RK370 fire valves comprise a two-part steel body (casing), which is rectangular in the case of V370 and round in the case of RK370, cut-off partition of PROMATECT boards, placed at the joint of both parts of the body, elements distancing (insulating) both parts of the body, and additional securing elements carrying out the fundamental task of stopping the air flow in the event of fire, namely: elements retaining and setting the mobile partition in the open or closed position (lever-spring mechanism or a BELIMO actuator), thermal trigger (mechanical or electrical thermal element). Valves can be furnished with a thermal trigger adjusted to actuation at the temperatures of 72±5 C or 90±5 C. For V370 valves, both parts of the body are terminated on both sides with flanges with the height of 30 mm, made as a whole with the body, by bending a part of body plate at the straight angle, while in the case of RK370 valves, this is a muff connection. Valve partition drive is located outside its rotating shaft. The valve is basically placed in the fire barrier (wall or ceiling). In the case of a different flap situation against the fire barrier, continuity of fire resistance must be preserved at the section from the fire barrier to the surface crossing the valve, as marked on the assembly diagrams. V370 valves are manufactured in variants HO; HE; MR and ER. Valve sizes are made of combination of sizes BxH for: B = 150; 200; 250; 300; 350; 400; 450; 500; 560; 630; 750; 800; 900; 1000; 1100; 1200, 1250, 1300, 1400 and 1500 mm H = 200; 250; 300; 350; 400; 450; 500; 600; 700, 800, 900 and 1000 mm. On special request, valves can also be made with intermediate B and H dimensions. In the event where the width of the valve (dimension B) is greater than 1500mm, or the height of the valve (dimension H) is greater than 1000 mm, the valve with the required dimension is made as a battery of valves, comprising standard valves. The length of rectangular valves amounts to 370 mm regardless of their size. RK370 valves are manufactured in variants HO; HE; MR and ER. Sizes of such valves are 400; 500; 560 and 630 mm. Total length of RK370 valves amounts to 370 mm.

4 3. VERSIONS Depending on the type of the applied element that keeps the valve s partition in the open position, as well as furnishing, there are the following versions of the fire safety valves: 3.1. HO version with lever-spring mechanism, opened manually. Opening of the valve occurs by turning the manual lever, during which the return spring is stretched. The cut-off partition of the valve is kept open by the band, manual lever and release element suspended on the peg of the mechanical thermal element. Closure of the cut-off valve can occur as a result of: - automatically due to increase in the temperature of the flowing air to the temperature where the heat-responsive device of the thermal trigger breaks (gets unsoldered (standard 72±5 C). - Manually as a result of release of manual lever from the trigger this allows for periodical closure of the partition to control valve operation. The operation of the thermal trigger (mechanical heat-responsive device) involves air stream flowing round the thermal element (glass ball or soldered metal plates) causes heating of the liquid inside the ball (or solder), which causes breaking of the glass cover (or dissolution of solder), and as a consequence the valve closes when the air flowing through the installation achieves the temperature of ~72 C. V370/HO RK370/HO The actuation of the heat-responsive device releases the peg of the mechanical thermal element based on it, and the latter, by moving backwards, triggers the element blocking the partition of the valve blocking it in the open position. The spring mounted on drive shaft, via the lever system, closes and keeps the valve closed, pressing it to the resistance angle bars HE version with lever-spring mechanism, opened manually. The structure and operation of the valve in this variant is identical as in the case of HO variant. HE valves have a micro-switch installed, which via relevant electrical system allows for signalling the position of the valve partition, and makes it possible to use it in control systems (e.g. switching off the fan when the valve is closed).

5 V370/HE RK370/HE 3.3. Version with the solenoid MR version In the MR version, the drive system comprises manual lever with a return spring and a solenoid controlled with power gap. Opening of the valve occurs by turning the manual lever, during which the return spring is stretched. The cut-off partition is kept open by the keeper of solenoid powered with 24V DC, connected to the power installation via micro-switch on the heat-responsive device. On request of the ordering party, a valve of this type can be furnished with a rectifier transformer powered with 230V AC. Closure of the cut-off valve can occur as a result of: - automatically, as a result of increase in air temperature to the temperature where the heatresponsive device of the electrical thermal element is actuated and contacts of the trigger micro-switch are switched, and power supply to the solenoid is disrupted, or as a result of disconnection of solenoid power supply by the control unit as a result of signals from other sensors connected in the control system. - manually by disconnecting power supply for the solenoid by a switch from the fire safety control unit to periodically control valve operation. Breaking (unsoldering) of the heat-responsive device in the trigger causes withdrawal of micro-switch keeper and disrupting power supply to the solenoid. The spring installed on the drive shaft is released and, via the lever system, causes closure of the partition. Additionally installed limit micro-switch, via relevant electrical system allows for signalling the position of the valve partition, and makes it possible to use it in control systems. Regardless of the type, valves with a return spring made of wire with diameter of 3 mm are furnished with solenoid with keeper holding strength of 120 N. Valves with a return spring made of wire with diameter of 3.5 mm are furnished with solenoid with keeper holding strength of 200N N ER version Opening and keeping the valve partition in the open position in this version, as well as its closing, is performed by one of electrical actuators of BF series (including digital actuators) or BLF series by Swiss company BELIMO, specially adjusted to operate fire safety valves. The actuators can be powered with 24 V DC and AC voltage or with 230 V AC voltage. BLF type actuators are applied in fire safety valves with the width not greater than 800 mm and height not greater than 500 mm. Closure of the valve partition occurs automatically as a result of gap in power supply to the actuator. Gap in power supply to the actuator can be caused by: - increase in air temperature to the temperature where heat-responsive device of electric thermal element is actuated and disconnects power supply to the actuator. - disruption of power supply to the actuator from the signal from fire safety control unit. Depending on the actuator type applied, the heat-responsive device is used, the operation of which is identical as in the case of MR type fire safety valve, or some actuator types are manufacturerfurnished with their own trigger BAE72-S or BAE72. Electric actuator kept live all the time maintains the valve in the open position. Upon a gap in power supply, the return spring on the drive shaft, using its accumulated mechanical energy, via the drive system, closes the partition and keeps it closed. In the case of valve closure caused by power shortage, reconnection of power will cause valve opening. If power shortage, however, was caused by actuation of the electrical thermal element, reopening of

6 fire safety valves can only be possible after replacement of the thermal element, on condition no other elements of the valve have been damaged. BELIMO actuators feature installed micro-switches that signal drive shaft rotation by 5 and 85 (position signalling), hence it is not required to install additional micro-switches informing about position of the partition. BF24TL-T-ST (digital) actuator is connected to the communication bus, which allows for monitoring of the valve by the centralised system. The above drive types refer to both round and rectangular fire safety valves. 4. PRINCIPLES FOR INSTALLATION OF FIRE VALVES 4.1. GENERAL REMARKS Before starting the installation of fire valves, do the following: Check for conformity of the device supplied with the design (type, variant, size and power supply voltage) Check whether there are no visible signs of damage during transport or storage at the site Check for completeness of the device, and its operation in justified cases, and prepare the valve for installation. Checking valve operation comprises their opening and closing, and observation of the valve during these activities. All valves are supplied in the closed position. Valves in HO and HE versions By turning the manual lever (item 1 Fig. 1a or 2a) clockwise for V370 valves and anti-clockwise for RK370 valves, switch the cut-off partition of the valve from "closed" to "open" position, at the same time stretching the closing spring. After turning the lever to full opening of the valve, hook the lever on manual trigger (item 23 Fig. 1a or 2a), wire protruding from the thermal element (item 3 Fig. 1a or 2a) so as to keep the valve open. After releasing the manual lever from the catch, the stretched spring shifts the partition from open to closed position. Movement of the partition when opening and closing must be smooth, without stops, binds, and excess resistance. Valve partition must adhere to ventilation seals on resistance profiles on the entire circumference. Valves in MR version Checking the operation of the valves (Fig. 1b; 1d and 2b) is analogical as in the case of HE and HE versions, except for holding and releasing the manual lever. In order to check these valve versions, connect relevant voltage to the solenoid (Fig. 1b; 1d and 2b item 3) or transformer (Fig. 1b; 1d and 2b item 4) via switch allowing for switching the power supply on or off. While checking, switch off power supply and manually open the valve, contacting the keeper (Fig. 1b and 2b item 2) with the solenoid (Fig. 1b; 1d and 2b item 3). Valve partition must be kept open by the solenoid. Then disconnect the solenoid s power supply. The partition should move to the closed position. Movement of the partition when opening and closing must be smooth, without stops, binds, and excess resistance. Valve partition must adhere to ventilation seals on resistance profiles on the entire circumference.

7 Valves in ER version Valve in this version, without connected power supply of the solenoid, is in the closed position (Fig. 1c and 2c item 1). By turning the crank at the BELIMO actuator in the direction marked on the actuator, we open the partition. After complete opening, when the crank is released, the spring wound on the actuator shaft should automatically close the partition and keep it in this position. Similarly as in the case of other versions, movement of the partition when opening and closing must be smooth, without stops, binds, and excess resistance, and valve partition must adhere to ventilation seals at the entire circumference. Type V370 Version HO, HE Version MR Version ER Type RK370 Fig. 1a Fig. 1b Fig. 1c Version HO, HE Version MR Version ER Fig. 2a Fig. 2b Fig. 2c Check for the size and shape of openings prepared in the walls to set the valves acc. to section Check whether after valve installation it will be possible to open them and access them from the maintenance side (valve drive) to allow for possible replacement of elements or periodical check If discrepancies are found, take explanatory measures and achieve conformity with the requirements REQUIREMENTS FOR THE SIZE AND SHAPE OF OPENINGS FOR FIRE VALVE ASSEMBLY DEPENDING ON THE TYPE OF THE WALL Requirements for the size and shape of openings for valve installation in the brick wall. For round valves RK370 For rectangular valves V370 Valve height Opening height Valve width Opening width

8 The axis of the opening made must be in the axis of the ventilation duct installed Requirements for the size and shape of openings for valve installation in the wall of cardboardplaster boards. For rectangular valves RK370 For round valves V370 Bearing profile plaster wall Bearing profile plaster wall Plaster boards Plaster boards 4.3. PRINCIPLES FOR INSTALLATION OF FIRE VALVES Assembly of the valves must correspond to one of the installation variants acc. to section The partition s rotation axis can be horizontal or vertical for V370 valves Air flow direction via the valve is of no significance for its assembly method (before or after the partition) Valves in standard version cannot be exposed to weather conditions or chemically aggressive environment Valve installation can be performed in a vertical fire barrier The applied assembly materials and the suspension method must prevent unintentional change of the valve position against the fire barrier The valve must be connected to the ventilation installation without any tensions, in a durable and leak-proof manner In the closed position, the partition must adhere to the resistance angle bars inside the casing on the entire circumference On both sides of the valve partition inside the ventilation duct, there must be free space to allow for its opening Electrical installation of the signalisation and powering of the drive elements must be made according to the schematic diagrams for the relevant valve version, according to section After installation of the element in the fire barrier (depending on the version, valve or duct), sealing must be provided between the fire barrier and the element installed, according to the adopted version. After sealing, check for correct operation of the valve and whether the elements of the valve drive have not become dirty. If so, clean them After installation of the fire valve and test operation, perform the commissioning confirmed with acceptance document. CAUTION: When assembling joint valves (valve batteries), apply all the same principles as for single valves FIRE VALVE INSTALLATION VARIANTS. Depending on the designed valve situation as regards the fire barrier, there are the following installation variants: - in the fire barrier, - remote from the fire barrier. A special case of valve situation against the fire barrier is the installation on the surface of the barrier. For fire barrier class EI120, required thickness G amounts to:

9 - barrier made of concrete mm, - barrier made of cellular concrete blocks or full brick mm, - light barrier, e.g. of plaster board mm The valves installed inside the opening in a concrete or brick fire barrier acc. to diagram in Fig. 6a and 6b Place the valve in the fire barrier, in the previously prepared opening acc. to section In fire barriers of class EI120 (walls or ceilings) made of concrete, brick, cellular concrete blocks or full brick with the above thickness G (Fig. 6a and 6b), the cut-off partition of the valve should remain within the axis of the partition. Assembly of the valves in this version in fire barriers class EI120, but with greater thicknesses must be made observing partition depth acc. to Fig. 6a and 6b, flange distance from the partition on the side without the drive must not be greater than values in Table 1. Table 1 Fire barrier made of: concrete cellular concrete blocks full brick Flange distance from partition for valves V370 and RK mm 32.5 mm 32.5 mm This requirement means that valves of V370 or RK370 type should protrude from the wall on the drive side to the distance not greater than B=222.5 mm Connect the valves with the suspended ventilation ducts on both sides of the fire barrier.

10 Type V370 Type RK370 duct valve duct valve drive Drive board Fire barrier Cement, lime-cement mortar or promastop MG III Cement, lime-cement mortar or promastop MG III Fire barrier Fig. 6a Fig. 6b The gap between the valve casing and the fire barrier must be carefully filled with cement, lime-cement mix or PROMASTOP MG III fire-protective mortar. It is prohibited to force in any pieces of brick or concrete while sealing, as this might lead to deformation of the casing (particularly in cases of valves with large cross-sections), and thus prevent free rotation of the partition and its closure (friction in slide bearings, or friction between the partition and the casing) Valves installed in a light fire barrier made of plaster and cardboard boards acc. to diagram in Fig. 7a and 7b Place the valve in the fire barrier opening prepared acc. to section so that, for barrier with class EI120 and thickness of 125 mm, the cut-off partition of the valve should remain in the axis of barrier thickness. Valves of V370 type must protrude from the wall on the drive side to the distance of 218 mm, while valves of RK370 type must protrude from the wall on the drive side to the distance of 213 mm. Assembly of valves in this version in fire barriers with lower fire resistance classes must be made observing valve setting against the barrier acc. to the data in Table Connect the valves with the suspended ventilation ducts on both sides of the fire barrier After appropriate valve setting in the fire barrier, seal it with mineral wool with thickness of min. 100 kg/m 3 and cover the wall with plaster boards acc. to Fig. 7a; 7b and 7c.

11 Type V370 Plaster boards Plaster board 12.5mm 4 layers Metal profile of plaster wall Angle bar metal strip 50x25x1 Cut-off partition Mineral wool with thickness of min. 100kg/m 3 or fire-safety foam e.g. PROMAFOAM Suspended ventilation duct Plaster boards Steel profile of plaster Bilateral sealing of the valve and wall with fire-safety mass e.g. PROMASEAL-Mastic drive drive Fire-safety foam e.g. PROMAFOAM Mineral wool min. 100kg/m 3 Plaster board 12.5mm Screws for plaster Mineral wool min. 100kg/m 3 Suspended ventilation duct Valve installation before assembly of ventilation ducts. Fig. 7a Valve installation ventilation ducts. with simultaneous assembly of Fig. 7b

12 Type RK370 Plaster boards Screw 3.5x25mm Steel profile of plaster w. Detail Fig. 7c Fixing clamps 4 items Mineral wool Valve RK370 Bilateral sealing of valve and wall with fire-safety mass e.g. PROMASEAL- Mastic drive Plaster board12,5mm overlay Mineral wool Plaster boards around Mineral wool Plaster boards around Mineral wool min. 100kg/m 3 Fig. 7c Valve installed remote from the fire barrier acc. to diagram in Fig. 8a and 8b Distance from the fire barrier is marked as length X of ventilation duct protruding from the wall constituting the fire barrier acc. to Fig. 8a and 8b Place the duct in the fire barrier in the previously prepared opening acc. to section 4.2. at the appropriate length X, ensuring the designed distance of the valve from the fire barrier Assemble the valve with the duct so that its drive remains outside the insulation (cf. Fig. 8a and 8b) Install ventilation ducts to the valve on one side and to the duct in the fire barrier on the other, suspending them at a distance not greater than 3 m from the fire barrier axis Such suspended duct with the valve after relevant setting in the fire barrier must be sealed with insulation meeting the requirements of fire insulation of the barrier, e.g. conlit Section (X +120) mm of the duct and valve type V370 acc. to Fig. 8a, and section (X + 100) mm of the duct and valve type RK370 acc. to Fig. 8b, must be insulated with PROMATECT L 500 boards with 52 mm thickness. At the joint of the valve with the fire barrier, at the entire circumference, make an additional band of PROMATECT L or L 500 boards with the thickness of 52 mm acc. to Fig. 8a or 8b. Such an insulation coating must be closed from the head with PROMATECT L 500 board with the thickness of 30 mm. Before the frontal closure of the insulation coating, tightly fill the gaps between the valve body and the internal circumference of the coating with stripes of mineral wool with the cross-section 10x28 mm, and place a layer of PROMASTOP on it Frontal closure of the insulation coating for valves of V370 type must be made with stripes of PROMATECT L or L500 board with thickness of 30 mm, width 81 mm and lengths allocated according to cross dimensions of the valve installed, so that along sides B, there are stripes by 2.5 mm longer than nominal dimension, and along sides H, there should be stripes by 164 mm longer than nominal dimension of the side. Stripes of the board along side B can have cuts of 3 mm each on both ends along dimension B, and 30 mm along the width of the stripe (81mm). In turn, in the case of valve of RK370 type, as frontal closing, make a blind of PROMATECT L or L 500 board with thickness of 30 mm in the form of square with dimensions Dn mm with opening cut in the axis, with diameter Dn mm. The blind installed at the circumference of the valve body must be sealed with PROMASTOP COATING and MG III, and to the casing coating after prior gluing.

13 Particular elements of the valve installation must be glued with PROMAT K84 and screwed at the spacing of ~150 mm with screws 6.0 x 90 for plaster boards The insulated duct with the valve must be suspended at sites marked in Fig. 8a and 8b. Mineral wool Promatect L500 Fire valve Duct Suspension axis drive Suspension axis Fire barrier RK370 Type V370 Fig. 8a Promatect L500 Mineral wool min. 100 kg/m^3 Promatect L500 Fire valve Fire barrier Duct Suspension axis drive Suspension axis suspension Fire barrier Promatect L or plaster boards Fig. 8b Valves installed on the surface of fire barrier Valves installation in this manner is a special case of remote valve installation, where value (X) of valve distance amounts to 0 mm, acc. to Fig. 8c and 8d Further procedure is analogical as in the case of section except for number of valve suspensions. Mineral wool min. 100 kg/m^3 Duct Suspension axis Promatect L500 drive Fire valve Duct Suspension axis Mineral wool min. 100 kg/m^3 Promatect L500 Drive board Fire valve Fire barrier Fire barrier Fig. 8c Fig. 8d

14 4.5. DIAGRAMS OF ELECTRICAL CONNECTIONS OF FIRE VALVES. NORMAL STATE Control cabinet transformer Control cabinet Thermal el. Thermal el. solenoid solenoid Limit switch Limit switch FIRE SIGNALLING FROM SAP Thermal el. Control cabinet Power shortage Thermal el. transformer Control cabinet Power shortage solenoid solenoid Limit switch Limit switch ACTUATION OF THERMAL ELEMENT Control cabinet transformer Control cabinet Thermal el. Thermal el. solenoid solenoid Limit switch Limit switch Control diagram for valve with solenoid

15 ER (BLF) ER (BLF-T) Thermal element Control cabinet 24/48V DC or 230V AC Control cabinet 24/48V DC or 230V AC actuator actuator Conceptual diagram of electric installations for valves in the ER version with BLF actuator 4.6. EXEMPLARY SYSTEMS FOR FIRE VALVE CONNECTIONS IN SIGNALLING AND CONTROL SYSTEMS If, in the rooms ventilated, there is fire alarm installation, it is recommended that the actuator of the ER fire valve and the solenoid of MR fire valve should be powered via contact controlled directly from the fire safety unit Diagram of connections of the actuator of fire valve version ER. Legend for connections of control and signalling circuits: Control cabinet 24/48V DC or 230V AC Signalling of fire valve closure circuit a" (lamp, switch, sound alarm, switching off the ventilation). Signalling of fire valve opening circuit c" (lamp, switch, ventilation switched on). Control of fire valve opening (lamp) actuator In the case of connecting BLF24-ST or BF24-ST actuators via BKN230-24, connect clamps 1 and 3 of thermal element with limit switch to clamps 1 and 2 on the BKN device (in place of the keeper, which must be removed) Diagram of connections of solenoid of fire valve version MR for installation powered with 24/48V DC thermal el. solenoid Limit switch conductor 1 Control cabinet 24/48V DC or 230V AC Legend for connections of control and signalling circuits: Signalling of safety thermal element actuation circuit a" (lamp, switch, sound alarm, switching off the ventilation). Signalling of fire valve closure circuit b" (lamp, switch, sound alarm, switching off the ventilation). Signalling of fire valve opening circuit c" (lamp, switch, ventilation switched on). Solenoid conductor in the MR version must be connected to closed contact in the electrical thermal element.

16 Diagram of connections of the limit switch of fire valve Limit switch c. 3 c. 2 conductor 1 Control cabinet 24/48V DC or 230V AC 5. PRINCIPLES FOR FIRE VALVES MAINTENANCE Legend for connections of control and signalling circuits: Signalling fire calve closure: connection a signals valve closure (depending on the control system, lamp is on, sound signal is on, ventilation is switched off). Signalling of fire valve opening connection b" (lamp or sound alarm is off, ventilation switched on). CAUTION: Before performing activities related to electrical connections or replacement of elements in the valves powered with voltage higher than safe, disconnect power supply Replacement of mechanical thermal element or melting fuse. Mechanical glass thermal element for valves type RK370 and V370 Fig. to section 5.1. Mechanical soldered thermal element for valves type RK370 &V370 After unscrewing two M5 screws (item 9 Fig. to section 5.1.) (optionally nut M6), remove the entire mechanical thermal element from the valve, item 1, together with plate, item 2. In order to replace the thermal element (item 3), unscrew the nut (item 4), press the spring (item 7) with the element, and after the element item 1 is bent to the side, remove the glass element (item 3) from the steel clip (item 6), or remove the protection (item 10) and remove the soldered element from the shank (item 11). After placing the glass element in the socket in the brass element (item 5), so that the elongated part of the insert is inside the element, or after placement of soldered element on the shank, assemble the thermal element in reverse order, not forgetting to place a sealing cushion (item 8) under the thermal element plate. The glass element must be set precisely in the socket and opening of the elements (item 6). The shank of the thermal element (item 11) must block the protrusion of the wired catch of the lever from the thermal element.

17 5.2. Replacement of electrical thermal element. Electrical glass thermal element for valves type RK370M Electrical soldered thermal element for valves type RK370M Fig. to section 5.2. Disconnect the trigger from electric installation and disconnect connections of the trigger at the valve. After unscrewing two M5 screws (item 4 Fig. to section 5.3.) (optionally nut M6), remove the entire electrical thermal element from the valve with the plate (item 1), as presented in the drawing below. In order to replace the thermal element (item 2), unscrew the brass cylinder or nut (item 3), place new thermal element in the opening or onto the shank (as presented in the drawing), and again screw on the cylinder on the micro-switch shank (item 5). Assemble the whole to the valve in the reverse order, not forgetting to place the sealing cushion (item 6). Connect the trigger to the electric installation and open the valve Replacement of the spring. Before replacing the spring, unscrew the screw (Fig. to section 5.4., item 3) fixing the manual lever on the drive shaft, set the valve partition in the closed position so that the spring tension is minimum (lever item 1 resting on the limiter, item 4), and next remove lever (item 1) and damaged spring (item 2). Place the spring on the middle opening in the manual lever and place the whole on drive shaft, item 5. During placement on drive shaft, manual lever must be set vertically, namely it should rest on the limiter on the drive board. Set the manual lever in the appropriate distance from the drive board and screw the screw fixing the lever on the drive shaft. Hook the spring on one of the catches (item 6) on the drive board, and assess the strength with which the partition is closed. If necessary, change the spring hooking on the drive board or manual lever, and again assess correct closing of the valve. Repeat these activities until your assessment is positive. Correct valve closure occurs where valve partition freely closes, and the manual lever meets resistance on the drive board without excess noise. After replacement of the manual lever, depending on valve version, reassemble the previously removed elements, and check for their correct operation. Fig. to s.5.3.

18 6. PERIODICAL MAINTENANCE The need for and the required frequency of maintenance results from analogical requirements of the installation including RK370 or V370 valves. If no specific requirements have been defined for periodical maintenance of the installation, or if the periods between particular checks are longer than six months, check the RK370 or V370 valves at least once every six months. This is the responsibility of the Facility Owner. Periodical maintenance of RK370 or V370 valves comprises the Close assessment of their physical condition, and correct operation using the Inspection Document at the end of this Documentation. Open It is also recommended to assess the condition of the device using the Inspection Document after the end of assembly works and launch of the installation including the RK370 or V370 valves. In order to check correct valve operation, do the following: Open Closed Fig HO and HE versions release manual lever (item 1 Fig. 13) from the catch (item 2 Fig. 13) keeping the valve open. After releasing the lever, it moves freely from the open to closed position, closing the valve partition. Next, manually open the valve, and hook the manual lever (item 1) at the element (item 2). For valves in HE version, during the test, observe correct signalling by micro-switch (item 3) of cut-off partition's position. If irregularities are found, set the micro-switch actuation point (item 3) MR version disconnect power supply to the solenoid. The partition should move to the closed position. Then disconnect the solenoid s power supply. In MR version, manually turn the manual lever, leading to contact of the keeper and the solenoid. After the partition achieves open position, the manual lever will be blocked by resistance of the keeper against solenoid coil, and valve partition will remain open, kept by the solenoid. During the test, in both cases, observe correct signalling by microswitch of cut-off partition's position. In the event of problems with sustaining the partition, check for cleanliness of keeper and solenoid surface ER version disconnect power supply to the BELIMO actuator. The valve must close (signalled by the steel arrow installed at the actuator axle at 0 position of the scale (Fig. 15 item 1). Fig. 15 Operation of the air-handling installation with dysfunctional fire valves bears the high risk of their non-performance in the event of a fire, and makes the installation user liable.

19 7. LIST OF SPARE PARTS 1. BELIMO actuators types acc. to table in section Solenoid type acc. to section Rectifier transformer AC 230 / DC Mechanical thermal element. 5. Electrical thermal element. 6. ESTI thermal element. 7. Soldered thermal element for mechanical trigger. 8. Soldered thermal element for electrical trigger. 9. Micro-switch Z-15GW Closing spring wire 03, 03.5 and 0.4 mm. The valves do not feature wearing or recommended parts. 8. TECHNICAL DATA OF ACTUATORS AND SOLENOIDS 8.1. Technical data of BELIMO actuators. Actuator type with release spring Parameters BF24(-ST) Supply voltage Power consumption While opening While keeping open position BFT24 BF24-T 24V~ ±20%, 50/60Hz BF230 BFT230 BF230-T BLF24(-ST) BLF24-T-(-ST) AC 230 V 50/60Hz AC 24V, 50/60Hz BLF 230 BLF 230-T AC 230 V 50/60Hz 7 W 8 W 5 W 5 W 7 W 2 W 3 W 2.5 W 3 W 2 W BF 24TL-T-ST AC 24 V 50/60Hz DC 24V Rated power 10VA 12.5VA 7 VA 7 VA 10 VA Protection class III II III II III Protection level IP42 IP42 IP54 IP54 IP54 Auxiliary 2xEPU 6(3)A, 2xEPU 6(3)A, 2xSPDT 6(1.5)A, switch 250V 250V AC250V 2xSPDT 6(1.5)A, AC 250V Connection point 5, 80 5, 80 5, 80 5, 80 Movement time Actuator 140s ~16s 140s ~40 75s (0 4Nm) ~40 75s (opening) (@ tamb=20 C) ~16s ~20s at -20 (0+4Nm) Spring (@ tamb=20 o C) +50 o C; ~20s at -20 max 60s at +50 o C +50 o C; max 60s at +50 o C (closing) Position indicator Ambient temperature Noise intensity Mechanical with indicator Mechanical with indicator Mechanical with indicator Mechanical with indicator Socket to connect BKN230-24LON or BKN230-24MP ~140 s ~16 s at ambient temperature 20 o C; Mechanical with indicator o C o C o C o C o C Motor max.45db(a); Spring ~62dB(A) Durability min settings Maintenance Maintenancefree 8.2. Technical data of solenoids Motor max. 45dB(A); Spring ~62dB(A) min Motor max.45db(a); spring ~62dB(A) Motor max.45db(a); Spring ~62dB(A) min Motor max.45db(a); Spring ~62dB(A) min min settings settings settings settings Maintenance-free Maintenance-free Maintenance-free Maintenancefree Types holding when power supply is on (MR) Type P Supply voltage 24 V DC 24 V DC Holding force 120 N 200 N

20 9. FIRE VALVE INSPECTION DOCUMENT To be downloaded from Parameter / Function 1. Valve checked 2. Date of check 3. Optical valve condition (mechanical damage, openings, rust, dents) 4. Valve cleanliness - cleaning if necessary 5. Assessment of the condition of conductors powering the actuator, solenoid, and limit switches 6. Assessment of the condition of the partition and the seals expansion and ventilation seal 7. Check of correct closing of valve partition 8. Physical check of valve response to OPEN / CLOSE control signals 9. Check of return signal from the valve (limit switches) 10. Check of functioning acc. to fire scenario 11. Leaving the valve in the normal operating condition Result Performed by:

TECHNICAL-OPERATIONAL DOCUMENTATION RK370M FIRE SAFETY VALVES

TECHNICAL-OPERATIONAL DOCUMENTATION RK370M FIRE SAFETY VALVES TECHNICAL-OPERATIONAL DOCUMENTATION RK370M FIRE SAFETY VALVES MANUFACTURER: FRAPOL Spółka z o.o. 30-832 Kraków, ul. Mierzeja Wiślana 8 Phone: (012) 653-27-66, 653-27-67, 653-26-92 fax (012) 653-27-89 MARCH

More information

7/S5 FIRE DAMPER FD40. v 2.9 (en)

7/S5 FIRE DAMPER FD40. v 2.9 (en) 7/S v.9 (en) FIRE DAMPER FD0 www.klimaoprema.hr 69 FIRE DAMPER - FDC TABLE OF CONTENTS FIRE DAMPER FD0 7 FIRE CLASSIFICATION 7 SELECTION DIAGRAM 7 ORDERING KEY 7 DAMPER MODELS 7 FD0-M rectangular fire

More information

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

7/S1 FIRE DAMPER PPZEN. v 2.5 (en) 7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...

More information

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages

More information

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

7/S6 FIRE DAMPER FDC40. v 2.9 (en) 7/S6 v.9 (en) FIRE DAMPER FDC0 www.klimaoprema.hr 8 TABLE OF CONTENTS FIRE DAMPER FDC0 87 FIRE CLASSIFICATION 87 SELECTION DIAGRAM 88 ORDERING KEY 88 DAMPER MODELS 89 FDC0-M cylindrical fire damper with

More information

PKIR3G, PKIS, PKIS3G and PKIS3GA

PKIR3G, PKIS, PKIS3G and PKIS3GA PKIR3G, PKIS, PKIS3G and PKIS3GA Fire Dampers Fire resistance EI60S, EI90S and EI120S 1396 - CPR - 0076 1396 - CPR - 0077 1396 - CPD - 0062 Ordering codes Dimensions Type of activation PKIR3G 1) - ødn

More information

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB Valid from //06 EN 5650:00-09 FIRE DAMPER FDMB These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMB. It is valid for production, designing,

More information

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD TPM 075/09-DK VALID FROM: 15/1/2012 I. CONTENT These technical specifications state a row of manufactured sizes and models of fire dampers and fire dampers

More information

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA 96 - CPR - 0 ORIGINAL INSTALLATION, MAINTENANCE AND OPERATION MANUAL EVERY SMOKE DAMPER NEEDS TO BE INSTALLED IN ACCORDANCE WITH THIS MANUAL! / PP-5_0604 DKISMA

More information

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm. Fire damper pl-30 General characteristics Application Fire dampers prevent fire and smoke from spreading through ventilation ducts in buildings. The dampers are intended for use inside buildings and are

More information

Systemair Fire Dampers

Systemair Fire Dampers Fire safety products 1 / 7 Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S 1396 - CPD - 0061 1396 - CPD - 0062 Ordering codes Ordering Codes for Circular FD: Fire resistance class

More information

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN Fire damper BKA-EN with general technical approval Z-41.3-667 tested according to DIN EN 1366-2 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Phone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980

More information

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance 07/2013 Fläkt Woods FIFLO EN 2013.07 2 ZU CLOSED AUF OPEN Fire damper ETPS-EI Contents Operation and Maintenance

More information

PKI-C Cartridge Fire Dampers

PKI-C Cartridge Fire Dampers Fire Safety Products / 7 PKI-C Cartridge Fire Dampers Fire resistance class EI60S, EI90S and EI0S 96 - CPD - 000 Ordering codes Fire resistance class PKI-C-EI - 60S, 90S and 0S Codes section. The thermal

More information

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION air handling intelligence FIRE SFETY Fire Damper in libraries of EI 10 (v e -i o) S EN 13501-3+1:01 EN 15650:0 Certificate of Conformity 1488-CPD-081/W EUROPEN PTENT PPLICTION EP 01158318 GOLD MEDL MTP

More information

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of FIRE SAFETY Fire Valve in libraries of EI 60 (v e -o i) S EN 131-3+A1:10 EN 156:10 Certificate of Conformity 1488-CPD-02 82/W FUNCTION The fire valves are designed for buildings where in the event of a

More information

Systemair Fire Dampers

Systemair Fire Dampers Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S www.systemair.com As standard, all fire dampers are designed and certified to comply with EI-S performance attributes. fire dampers

More information

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings

More information

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8. Fire safety products 1 / 8 DKISMA Systemair multicompartment rectangular smoke control dampers Resistance class EI120(v ew i o) S1500C mod AAmulti 1396 - CPR - 0112 Ordering codes Nominal dimensions Type

More information

SMOKE CONTROL DAMPERS

SMOKE CONTROL DAMPERS SMOKE CONTROL DAMPERS 96 - CPD - 0058 Round DKIR and Rectangular DKIS ORIGINAL INSTALLATION, OPERATION AND MAINTENANCE MANUAL EVERY SMOKE DAMPER NEEDS TO BE INSTALLED IN ACCORDANCE WITH THIS MANUAL! /

More information

Bevent Rasch BSK Fire /04/2017

Bevent Rasch BSK Fire /04/2017 Bevent Rasch - Fire - BSK120 10/04/2017 Rectangular Fire resistance class /S Sizes from 200 x 200 mm to 1200 x 1000 mm Prefitted safety actuator 24V or 230V Available in MagiCAD CE-marked building product

More information

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Fire Dampers. Types FKA FRL FRK 4/1/EN/1 Fire Dampers Types FKA FRL FRK /1/EN/1 Contents Description Description... Construction... Standard Sizes Installation Details... Functional Description Product Range... Accessories... Circuit Diagrams...

More information

Fire damper FK120/FK90 TECHNICAL DATA

Fire damper FK120/FK90 TECHNICAL DATA Fire damper FK120/FK90 TECHNICAL DATA 2 Fire damper FK120/FK90 Figure 1 ER1 Figure 2 ER3 The rectangular fire damper FK120/FK90 is available both as motorized and with fuse. The damper casing is manufactured

More information

Bevent Rasch BSK6. - Fire /04/2017

Bevent Rasch BSK6. - Fire /04/2017 Bevent Rasch - Fire - BSK6 11/04/2017 Fire resistance class EI60 / EI60S Sizes from 200 x 200 mm to 800 x 800 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product

More information

Fire and Smoke Damper Actuator product overview

Fire and Smoke Damper Actuator product overview Fire and Smoke Damper Actuator product overview Fire and Smoke protection Spring-Return Actuator BLF.. BF.. BFG.. FSLF..US FSNF..US FSAF..US Agency listing CE certification UL555 and UL555S Torque - Motor

More information

TECHNICAL PRODUCT DOCUMENTATION

TECHNICAL PRODUCT DOCUMENTATION Page: 1 POSITIONER TYPE A703 Page: 2 CONTENTS 1. APPLICATION 3 2. TECHNICAL DESCRIPTION 3 2.1. Construction 3 2.2. Working rules 4 2.3. Dimensions of the positioner and types of performances 6 3. TECHNICAL

More information

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 5868/5869 EN Electric Control Valves Types 3213/5857, 3213/5824, Types 3214/5824, 3214/3374, 3214/3274 with safety function: Types 3213/5825, 3214/5825, 3214/3374, 3214/3274 Pneumatic Control Valves Types 3213/2780-1,

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SFG- Spring return actuator with emergency function in the IP66 I protective protecti e housing for adjusting air dampers in industrial plants and in technical building installations

More information

Smoke damper EKO-SRB1

Smoke damper EKO-SRB1 Smoke damper EKO-SRB1 Description The EKO-SRB1 smoke damper is a CE-approved damper in fire class E60 intended for fire compartmentation or protection against the spread of fire and smoke in ventilation

More information

D10 Page. Contents. Complete Equipment with Scope of Supplies 2. Accessories 3

D10 Page. Contents. Complete Equipment with Scope of Supplies 2. Accessories 3 01.2009 UK D10 1 D10 Page Contents Complete Equipment with Scope of Supplies 2 Accessories 3 Spare Parts D10-III 230V / 400V 4-5 Motors D10 universal 6 Transport shaft, mixing shaft 7 Electric Control

More information

SERIES 2000 GAS SAFETY SHUT OFF VALVE

SERIES 2000 GAS SAFETY SHUT OFF VALVE APPLICATION 2 Series 00 Solenoid Valves are Safety Shut-off or Control Valves for use on gases in gas families 1, 2 and and are also suitable for use with air within the valves pressure range - see specification.

More information

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS INSTALLATION, MOUNTING AND OPERATING BSK-EN Fire damper Contents Description... 2 Models and dimensions... 3 Mounting information... 5 Installation information... 6 Technical data... 7 Accessories... 9

More information

Fire/smoke damper EKO-SRBG1

Fire/smoke damper EKO-SRBG1 Fire/smoke damper EKO- Description The EKO- fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.

More information

Fire/smoke damper EKO-JBG2

Fire/smoke damper EKO-JBG2 Fire/smoke damper EKO-JBG2 Description The EKO-JBG2 fire/smoke damper is a CE-approved damper intended for fire compartmentation or protection against the spread of fire and smoke in ventilation installations.

More information

Heights up to 1000 mm Fire resistance period up to 120 minutes

Heights up to 1000 mm Fire resistance period up to 120 minutes Maintenance-free FK90 fire dampers - series FK120 - Heights up to 1000 mm Fire resistance period up to 120 minutes Fire classification: EI 30/60/90/120 (ve - ho, i o) S C10ooo Hygiene certificate Environmental

More information

Actuators for Fire and Smoke Protection Dampers

Actuators for Fire and Smoke Protection Dampers OpenAir TM Actuators for Fire and Smoke Protection Dampers GRA126.1E/... GRA326.1E/... Electric motor driven actuators for 2-position control, nominal torque 4 Nm, with spring return to failsafe position,

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3 SA/6/1/EN/3 Fire Dampers Type FDF Compliant to SABS (193:2004) TROX (South Africa) (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax. +27 (0)33 398 1100 email : pmb@troxsa.co.za

More information

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency Technical data sheet NFG-S2-L Spring-return actuator with emergency control function for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque 10 Nm Nominal

More information

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas. Systemair Fire Dampers for Explosive Areas Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S www.systemair.com Description Fire damper (hereafter referred to as damper) is a fire

More information

Electromotoric Actuators

Electromotoric Actuators 4 506 SQL33 Electromotoric Actuators for valves with 90 angle of rotation SQL33 operating voltage AC 230 V SQL33 operating voltage AC 230 V operating voltage AC 24 V 3-position control signal Nominal angle

More information

VA-7450 Series. Electric Valve Actuators

VA-7450 Series. Electric Valve Actuators 34-636- 771, Rev. D Installation Instructions VA-7450 Series Issue Date 0216 VA-7450 Series Electric Valve Actuators Applications VA-7450 Series Electric Valve Actuators provide on/off, floating, or proportional

More information

Laminar ceilings, exhaust columns, exhaust grilles

Laminar ceilings, exhaust columns, exhaust grilles Laminar ceilings, exhaust columns, exhaust grilles 1 Table of Contents: 1. Laminar ceilings general information... 3 2. Laminar ceilings design and operation principles... 4 3. Parameters of air in the

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

1 Product Description System Layout Safety Instructions Intended Use Installation... 3 Order Number 0812xx- Contents 1 Product Description... 2 2 System Layout... 2 3 Safety Instructions... 3 4 Intended Use... 3 5 Installation... 3 5.1 Hanger Clamp... 3 5.2 Cutting of Conductor Rail... 4

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions RUC 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current

More information

Actuators for Fire and Smoke Protection Dampers

Actuators for Fire and Smoke Protection Dampers 4 617 OpenAir TM Actuators for Fire and Smoke Protection Dampers GGA126.1E/.. GGA326.1E/.. Electric motor driven actuators for 2-position control, nominal torque 18 Nm, with spring return to failsafe position,

More information

Fire Dampers Catalogue

Fire Dampers Catalogue Fire s Catalogue DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval UL 555 Classified 2013 For Use in Static & Dynamic Systems 3 Hour Rating Made in

More information

MC2500. Installation and Operation Manual

MC2500. Installation and Operation Manual MC2500 Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible to

More information

Operating manual LPS. Humidifies and Cools. ÁLPS.ENzÈ LPS.EN

Operating manual LPS. Humidifies and Cools. ÁLPS.ENzÈ LPS.EN Operating manual LPS Humidifies and Cools ÁLPS.ENzÈ LPS.EN 4.2.4 Atomising nozzles Desalinated water at a pressure of up to 16 bar reaches the nozzles where the water is atomised to form ultra-fine mist-like

More information

D58 Series Brake Instructions

D58 Series Brake Instructions D58 Series Brake Instructions 4740 W. Electric Avenue Milwaukee, WI 53219 414/672-7830 FAX 414/672-5354 www. dingsbrakes.com Safety information 2 Safety information 2.1 Persons responsible for the safety

More information

For installation into ductwork

For installation into ductwork X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum

More information

Technical documentation

Technical documentation VM-PRO Mechanical volumetric flow control- Table of Contents Areas of application... 2 Useable volumetric flow ranges... 2 Function... 3 Processing... 3 Available sizes / -dimensions... 4 Accessories list

More information

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type NAK. Gas-tight shut-off damper with pneumatic actuator Homepage > Products > Control units > Shut-Off dampers > Type NAK Type NAK FOR THE GAS-TIGHT SHUT-OFF OF DUCTS Gas-tight shut-off damper with pneumatic actuator Gas-tight shut-off dampers are designed

More information

FK120/FK90 FIRE DAMPER» INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE

FK120/FK90 FIRE DAMPER» INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE FIRE SAFETY AIR ANAGEENT FIRE DAPERS FK120/FK90 FIRE DAPER» INSTRUCTIONS FOR INSTALLATION, OPERATION AND AINTENANCE ZU CLOSED AUF OPEN 2 FK120/FK90 Fire damper Instructions for installation, operation

More information

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3 SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SF24G-S- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

Minimum 27 in-lb torque

Minimum 27 in-lb torque LU Series Actuator Minimum 27 in-lb torque For damper areas up to 6.8 sq-ft* All Actuators have BDCM LU Series - At A Glance LUB(X)24-3 (p. 258) LUB(X)24-SR (p. 260) LUX24-MFT (p. 262) Basic Product Flexible

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL SPECIFICATIONS PRODUCT DATA Supply voltage CN6105/CN6110 Nominal voltage CN6105/CN6110 24 Vac/dc

More information

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00

More information

Product card User manual. KP Strong Safe

Product card User manual. KP Strong Safe Product card User manual KP Strong Safe grade II and III with ECB-S certificate KONSMETAL Export Department export@konsmetal.pl KONSMETAL Service: phone: +48 89 6253799 (Monday Friday: 8-16) e-mail: serwis@konsmetal.pl

More information

Liv-Elir d.o.o. Contact Info: Tel/Fax.: Mob.: Mail: REPAIR AND SERVICE / PRODUCTION

Liv-Elir d.o.o. Contact Info: Tel/Fax.: Mob.: Mail: REPAIR AND SERVICE / PRODUCTION REPAIR AND SERVICE / PRODUCTION REPAIR AND SERVICE Asynchronous, synchronous and collector machines of low and high voltage: Production of coil insulation class B, F, H Production of coil for voltage level

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

LCU DX Efficient cooling with no loss of space

LCU DX Efficient cooling with no loss of space LCU DX Efficient cooling with no loss of space 2 Cooling for network and server enclosures Space-saving installation of the internal unit between the 482.6 mm (19 ) level and side panel Optimum support

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 3/2 and 4/2 directional seat valves with solenoid actuation RE 22049-XN-B2/08.12 Replaces: 07.10 Type M-.SED 6...XN... Size 6 Component series 1X Maximum operating pressure 350 bar Maximum flow 25

More information

USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008

USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008 诲眾 ᓠ 睂睄 睄 ɞ 1/7 ZETKAMA Spółka Akcyjna ul. 3 Maja 12 PL 57-410 Ścinawka Średnia USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008 Date: 01.01.2008 CONTENTS 1. Product description

More information

Operating and Installation Instructions

Operating and Installation Instructions Operating and Installation Instructions Sectional gate MakroPro 100 MakroPro Alu 100 installation type STL HL Catalog no. AW.03.40 Last Update - 10th May, 2006 IMPORTANT INFORMATION Please read these instructions

More information

Rectangular smoke damper (remote controlled)

Rectangular smoke damper (remote controlled) Clapets coupe-feu et Volets de désenfumage D.A.S. Organisme Certificateur AFNOR Certification - www.marque-nf.com VU10 Rectangular smoke damper (remote controlled) Rf-Technologies nv - Lange Ambachtstraat

More information

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR MANAGEMENT FIRE DAMPERS ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE 2 ETPR-E-1 Fire damper Technical catalogue Fire and smoke damper ETPR-E-1 is used as a closing device for preventing the

More information

Actuators for Fire Protection Dampers

Actuators for Fire Protection Dampers 4 620 OpenAir TM Actuators for Fire Protection Dampers GNA126.1E/T. GNA326.1E/T. Rotary version, 2-position control, with spring return and ready connected temperature monitoring unit, / DC 24 48 V / AC

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning

More information

BAH series Use and Maintenance Manual

BAH series Use and Maintenance Manual Page 1 of 15 BAH 225-280 series Use and Maintenance Manual Page 2 of 15 We would like to thank you for trusting us and buying our product. Field of application Before starting the motor, it s necessary

More information

CFSD Series. Product Description

CFSD Series. Product Description COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke

More information

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators M9208-Bxx-3 Series On/Off Electric Spring Return Actuators Installation Instructions M9208-BAA-3, M9208-BAC-3, M9208-BDA-3, M9208-BDC-3, M9208-BGA-3, M9208-BGC-3 Part No. 34-636-2103, Rev. B Issued May

More information

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444 Operation Instructions (translation) Explosion Protection Explosion protection is one option and is marked on the ex-type plate on the solenoid drive. The actuators and the associated solenoid controllers

More information

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve Type 3310/AT and Type 3310/3278 Pneumatic Control Valves Type 3310 Segmented Ball Valve Fig. 1 Type 3310/3278 with positioner Fig. 2 Type 3310/AT Mounting and Operating Instructions EB 8222 EN Edition

More information

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet SF24G-S-S2- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

Minimum 27 in-lb Torque

Minimum 27 in-lb Torque LU Series Actuator Minimum 27 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM LU Series - At A Glance LUB(X)24-3 (p. 351) LUX120-3 (p. 353) LUB(X)24-SR (p. 355) LUX120-SR (p.

More information

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant

More information

Parking space border or support. Drive axis 15 L

Parking space border or support. Drive axis 15 L Headroom according to local regulations 9,5 Warning light B Direction of movement KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D-319 Aitrach Fon +49 (0 ) 75 65 5 0-0 Fax +49 (0 ) 75 65 5 0- info@multiparking.com

More information

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings ST2 Ball valves in conjunction with spring return and non-spring return VA-Actuators Developed for HVAC applications

More information

Electromotoric Actuators

Electromotoric Actuators 4 508 Electromotoric Actuators for slipper valves with 90 angle of rotation SQK34.00 SQK84.00 SQK34.00 operating voltage AC 230 V SQK84.00 operating voltage AC 24 V 3-position control signal Nominal angle

More information

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

Cytotoxic Safety Cabinets ENVAIR eco safe Plus Cytotoxic Safety Cabinets ENVAIR eco safe Plus Class Cytotoxic Standard Width (m) II Safety EN 12469 0.9 / 1.2 Cabinet DIN 12980 1.5 / 1.8 Clean technology for a clean environment ENVAIR eco safe Plus

More information

E07 -Heavy Duty- Lifting Platform Technical Data Lifting system for a person with limited locomotory capacity

E07 -Heavy Duty- Lifting Platform Technical Data Lifting system for a person with limited locomotory capacity E07 -Heavy Duty- Lifting Platform Technical Data Lifting system for a person with limited locomotory capacity Approval TÜV approval for the safety gear; TÜV approval for the locks; In conformity with the

More information

0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table

0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table Type overview FSR with guide cables or rods Type key FSR P S 0 0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table Cover panel without back-fold: S = small,

More information

Versatile and Powerful

Versatile and Powerful LM Series Direct Coupled Actuator Versatile and Powerful Minimum 45 in-lb torque in a compact package. For damper areas up to 11 sq-ft* Actuators in bold have BDCM LM Series - At A Glance LMB(X)24-3(-S)(-T)

More information

Actuators for Fire and Smoke Protection Dampers

Actuators for Fire and Smoke Protection Dampers 4 617 OpenAir TM Actuators for Fire and Smoke Protection Dampers GGA126.1E/.. GGA326.1E/.. Electric motor driven actuators for 2-position control, nominal torque 18 Nm, with spring return to failsafe position,

More information

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators Installation Instructions M9206-Bxx-2S Issue Date May 14, 2003 M9206-Bxx-2S Series On/Off Electric Spring Return Actuators Installation IMPORTANT: Use this M9206-Bxx-2S Series actuator to control equipment

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

Operating manual Separator

Operating manual Separator Operating manual Separator Sheet no. AS/4.1.141.1.1 issue 20.08.2014 Contents Section Title Page 0 Introduction... 1 1 Intended use......1 2 Marking of the fitting... 1 3 Safety instructions... 2 4 Transport

More information

INSTRUCTION MANUAL MAGNA RAIL

INSTRUCTION MANUAL MAGNA RAIL R ENGLISH NR. 148293 00 INSTRUCTION MANUAL MAGNA RAIL 1999-05-01 List of contents Declaration of conformity, CE Delivery check Mounting instruction (rail, trolley units) Mounting instruction (exhaust pipe,

More information

Parking space border or support. Drive axis 15 L

Parking space border or support. Drive axis 15 L Page 1 Car Headroom according to local regulations 9,5 Warning light B Direction of movement KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D-319 Aitrach Fon +49 (0 ) 75 65 5 0-0 Fax +49 (0 ) 75 65 5 0-

More information

Electromotoric Actuators

Electromotoric Actuators 4 506 Electromotoric Actuators for valves with 90 angle of rotation operating voltage AC 230 V 3-position control signal Nominal angle of rotation 90 Auxiliary switch and potentiometer for extra functions

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

Rectangular fire damper TFER 30. pag. C-10

Rectangular fire damper TFER 30. pag. C-10 pag. C-10 Description Rectangular fire damper with CE label in conformity to UNI-EN 15650, certified according to EN 1366-2, classified EI 120 S in accordance to EN 13501-3. Removable shifted kinematic

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information