Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Size: px
Start display at page:

Download "Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise"

Transcription

1 Halton AWE/AWU Universal Grille Horizontal air supply, suitable also for exhaust Fixed front vanes, stable throw pattern with vertical 15 deflection: AWE, no deflection: AWU Adjustable rear vanes for horizontal deflection of the air jet Aluminium construction with elegant outlook Detachable grille enables cleaning of the grille and ductwork MATERIAL AND FINISHING PART MATERIAL FINISHING Continuous grilles available with modular construction Accessories Airflow adjustment damper Plenum options with measurement and adjustment functions Installation frame NOTE Frame Aluminium Anodised, Polyester-painted, White RAL % gloss, Mill finished Vanes Aluminium Anodised, Polyester-painted, White RAL % gloss, Mill finished Installation frame Plenum box / spigot Galvanised steel Galvanised steel Special colours available Epoxy-painting (100 %) available Special colours available Epoxy-painting (100 %) available ACCESSORIES ACCESSORY CODE DESCRIPTION Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise Plenum BDR Plenum for duct connection (with or without attenuation material) Airflow measurement and adjustment unit MSM For supply installation Sound attenuation IN Mineral wool for the BDR plenum box. Polyester fiber for the PRI plenum box. Flow adjustment damper OD Aluminium opposite blade damper~for airflow adjustment Installation frame IF For installation without plenum Concealed screw fastening CC For installation with BDR plenum or IF frame 1

2 18 L H1 H2 48 AWE L1 DIMENSIONS NS L1 L2 H1 H2 AWU Function Supply air is supplied with vertical 15 angle deflection and with horizontal deflection (rear vanes) through the vanes into the space, mixing with room air in front of the grille. The flow pattern is adjusted by changing the angle of the adjustable rear vanes. Wall installation for horizontal supply or ceiling installation for vertical supply. In wall installations, the recommended distance from the ceiling is 200 mm, when the supply air is directed to the ceiling.(awe) The grille can also be used as an exhaust unit.(awu) 200x x x x x x x x x x x x x x x x x x With flow control damper OD total depth = 48 mm + 45 mm. Special dimensions In addition to standard sizes, other sizes can be specially ordered. The maximum size is 1500x500 mm (LxH). It is possible to have a continuous grille of modular design when the installation length is greater than 1500 mm. The maximum total length is 20 m. 2

3 Installation frame (IF) PRI balancing plenum BDR plenum box Installation Concealed screw fastening (option) The grille is connected to the circular duct using either a PRI balancing plenum or a BDR plenum or alternatively directly to the rectangular duct using the IF installation frame. Clips fastening (standard) The grilles are supplied with clips fastening as standard. Clips fastening is used with PRI, BDR and IF. Concealed screw fastening is possible when the grille is installed with an installation frame (IF) or a BDR plenum, though not with a PRI balancing plenum. Holes for screws are provided in the BDR. For ceiling installation concealed screw fastening is recommended. Visible screw fastening is not possible due to the reduced width of the frame (18 mm). Size of the installation hole is LxH when installation frame is used, and (L-5)x(H-5) without installation frame. 3

4 K factor for installations with different safety distances (D= duct diameter) ØD PRI/S >8xD min 3xD Adjustment In order to enable airflow adjustment and measurement of airflow rate it is recommended that you connect the diffuser to the BDR plenum or PRI balancing plenum equipped with the MSM module. The supply flow rate is determined by using the MSM measurement and adjustment module. Detach the grille and pass the tubes and control spindle through the grille. Measure the differential pressure using a manometer. The flow rate is calculated using the formula below x x x x x x x x x x x x x BDR >6xD min 3xD q v = k * p m Adjust the airflow rate by rotating the control spindle until the desired setting is achieved. Lock the damper position with a screw. Replace the tubes and spindle in the plenum and replace the grille. Airflow adjustment damper OD The airflow rate is adjusted by turning the damper blades behind the grille using a screwdriver. The measurement is carried out when grille is installed. 4

5 Pressure drop, throw pattern and sound data AWE or AWU, wall installation at a distance of 200 mm from the ceiling (with Coanda effect) 200x50, 200x100, 300x100, 400x x100, 600x100, 800x100, 600x x100, 800x150, 1000x150, 800x200, 1000x x150, 1500x150, 1200x2000, 1500x200 Note : When there is no coanda effect (installation greater than 200 mm from ceiling) the throw pattern must be multiplied by 0.7. For exhaust use, adjust supply data by adding + 5 db(a) and DPs= DPs x

6 Sound power level with OD damper Use of an OD opposite blade damper, will result in increased pressure loss. The resulting increase in sound level is computed from the selection chart value and the formula below: LpA = DLp + LpA Kp= Adjusted pressure drop Pressure drop in selection chart Example : ALE-1000x150 + OD/ALE qv = 300 l/s LpA = 31 db(a) without damper OD/ALE DPs= 50 Pa (desired pressure drop) Kp = 50/11 = 4.5 LpA = = 45 db(a) Throw length correction factor When the throw length is adjusted with the rear vanes, the actual throw length is obtained by multiplying the value obtained from the selection chart by the correction coefficient K1. L0.2 (a) = K1 x L0.2 The correction coefficient K1 is the average for the various grille sizes. Pressure drop correction factor Angle between vanes When the throw length is adjusted with the rear vanes, the actual pressure drop is obtained by multiplying the value obtained from the selection chart by the correction coefficient K2. DPs (a) = K2 x DPs The sound level increases when pressure drop is increased. The correction coefficient K2 is the average for the various grille sizes. Angle between vanes 6

7 SOUND LEVEL DATA, SUPPLY AWE-AWU qv DPst DPtot F (Hz) LpA NR NC (l/s) (m 3 /h) (Pa) (Pa) [db(a)] 200x x x x x x x x x x x x x x x x x LpA values presented with room attenuation 4 db (red 10m 2 - sab). When using room attenuation 8 db (red 25m 2 - sab): LpA - 4dB. NR/NC noise criteria 7

8 Servicing Remove the grille by gently drawing it out by the frame. Use a screwdriver if necessary. Clean the parts by wiping then with a damp cloth. Push the grille back into place so that the clips lock (or fix by tightening the concealed screws). Product Code AWE-L-H AWU-L-H L = Length 200,+1,..,20000 Option: with balancing plenum PRI or BDR + MSM Remove the measurement and adjustment module by gently pulling the shaft (NB. not the control spindle or measurement tubes!). Wipe the parts with a damp cloth, instead of immersing in water. Reassemble the measurement and adjustment module by pushing the shaft until the module meets the stopper. Push the grille back into place so that the clips lock. Suggested Specifications H = Height 50,+1,..,500 Specifics and accessories FS = Fastening CL Clips CC Concealed screw fastening FI = Finishing AN Anodised MF Mill finished PN Painted The grille shall have horizontal fixed vanes with a 15 angle deflection:awe, no deflection: AWU and vertical adjustable rear vanes, and an 18 mm wide flat frame, anodised or epoxy-painted with a white (RAL 9010) colour. Flow pattern shall be adjustable by rear vanes. CO = Colour W X N Code example White Special colour No painting Option 1 The grille shall be connected to the ductwork using a plenum with mineral wool as sound insulation material. Option 2 The grille shall be connected to the ductwork using a balancing plenum, which comprises polyester fibre with a washable surface as sound attenuation material. The plenum shall comprise an airflow measurement and adjustment unit. The grille shall be removable in order to provide access to the measurement and adjustment module in the plenum. ALE , FS=CL,FI=AN,CO=N Sub products BDR Plenum PRI Plenum IF Installation frame (Grilles) OD Opposed blade damper (Grilles) 8

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille Halton WDD/WSD Universal Grille Horizontal air supply, suitable also for exhaust Adjustable vertical front vanes, adjustable horizontal rear vanes: WDD, adjustable horizontal vanes: WSD Aluminium construction

More information

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

AHF - Exhaust Grille. Halton AHF. Exhaust Grille Halton AHF Exhaust Grille Large free area, high airflow rates with minimal pressure drop Integrated filter of class EU3 Reduced visibility through grille due to shaped horizontal vanes Sizes adapted to

More information

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

HDF - Exhaust Grille. Halton HDF. Exhaust Grille Halton HDF Exhaust Grille Large free area Integrated filter of class EU3 Reduced visibility through grille due to shaped horizontal vanes Sizes adapted to suit modular 600 x 600 mm suspended ceilings Openable

More information

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser Halton DFA Conical Ceiling Diffuser Horizontal air supply, suitable also for exhaust Installation flush to the ceiling, light-weight aluminium design Circular duct connection with rubber gasket Openable

More information

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser Halton DFB Conical Ceiling Diffuser Horizontal air supply, suitable also for exhaust Installation flush to the ceiling, light-weight aluminium design Circular duct connection with rubber gasket All sizes

More information

GDD - Supply Grille. Halton GDD. Supply Grille

GDD - Supply Grille. Halton GDD. Supply Grille Halton GDD Supply Grille Horizontal supply, for circular duct installations For cooling and heating applications; suitable also for exhaust Adjustable vertical front vanes, adjustable horizontal rear vanes

More information

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser Halton THB Perforated Ceiling Diffuser Horizontal air supply, suitable also for exhaust Installation either directly to ductwork or balancing plenum Detachable front panel enables the cleaning of the diffuser

More information

TBV - Terminal Unit. Halton TBV. Terminal Unit

TBV - Terminal Unit. Halton TBV. Terminal Unit Halton TBV Terminal Unit Horizontal air supply, suitable also for exhaust Integrated rectangular balancing plenum with measurement and adjustment functions Effective sound attenuation Circular duct connection

More information

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser Halton TCM Conical Ceiling Diffuser Horizontal air supply, suitable also for exhaust Suitable for cooling applications with supply/room air temperature difference as low as -12 C Installation flush to

More information

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound Halton TSR/TSS Swirl Diffuser Radial horizontal air supply Air velocity is effectively reduced due to high mixing effect Circular duct connection with gasket All sizes available as an adapted version for

More information

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser Halton DKR Multi-nozzle Ceiling Diffuser Horizontal air supply, vertical air patterns are also possible Supply air pattern can freely be directed in up to four directions or alternatively radially as swirl

More information

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser Halton DKS Multi-nozzle Ceiling Diffuser Horizontal air supply, vertical air patterns also possible Supply air pattern can freely be directed in up to four directions or alternatively radially as swirl

More information

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser Halton TRB Conical Ceiling Diffuser Horizontal or vertical air supply, suitable for both heating and cooling applications Supply air jet velocity is effectively reduced due to high mixing effect Installation

More information

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser Halton THL Conical Ceiling Diffuser Horizontal or vertical air supply, suitable for both heating and cooling applications Adjustable throw pattern and pressure drop Installation flush to the ceiling, or

More information

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers Plenum for diffusers Halton reserves the right to alter products without notice 07/15 Plenum ensuring proper function of supply air ceiling diffuser and connecting to ductwork Flexibility for levelling

More information

DAC - Conical Diffuser. Halton DAC. Conical diffuser

DAC - Conical Diffuser. Halton DAC. Conical diffuser Halton DAC Conical diffuser Coanda effect provided with a wide range of air flow rates, thanks to the special profile of the diffuser blades Diffuser adapted for variable air flow Supply in four directions

More information

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser Halton DCS Ceiling Diffuser DCS/C DCS/A DCS/N DCS/J DCS/P Horizontal air supply, suitable also for exhaust Modular construction with five different, interchangeable front panel options suited for modular

More information

ULA - Valve. Halton ULA. Valve

ULA - Valve. Halton ULA. Valve Halton ULA Valve Supply/exhaust valve for ceiling and wall installation with adjustable pressure loss Installation without an installation frame directly into ductwork or a hollow-core slab Flow pattern

More information

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option ZSC - Halton Zen Semi-Circle Displacement ventilation unit Capacity for wide supply airflow range. Uniform supply air distribution is achieved through small perforations, providing optimal conditions in

More information

Halton PRL Plenum for grilles

Halton PRL Plenum for grilles Plenum for grilles Plenum for connecting supply/exhaust grille to ductwork Ensures proper function of the supply air grille Robust, airtight construction with aesthetically pleasing design Flexibility

More information

Aircell Polymer Range

Aircell Polymer Range Aircell Polymer Range S, D Aircell Adjustable Blade Grilles G, A Aircell Polymer Ehaust Grilles T Aircell Polymer Air Transfer Grilles E Aircell Polymer Eggcrate Grilles Aircell - S Aircell - D Aircell

More information

HIGH CAPACITY LINEAR SLOT DUFFUSERS

HIGH CAPACITY LINEAR SLOT DUFFUSERS HIGH CAPACITY LINEAR SLOT DUFFUSERS CB SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871

More information

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise LINEAR BAR GRILLES T SERIES Quality and e!ciency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk

More information

series Linear grilles

series Linear grilles series 30 Linear grilles www.koolair.com Series 30 1 CONTENTS Linear grilles 2 Linear floor grilles 3 Quick selection table 4 Example of selection 5 General dimensions 7 Accessories and mounting 10 General

More information

Compact Grille Model KG

Compact Grille Model KG Compact grille KG Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...3

More information

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 Installation dimensions AS/GS120 AS/GS130 Application The grille type AS / GS is used for the supply and exhaust of cooled or heated air in facilities

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

REK, LEK, ROK and LOK

REK, LEK, ROK and LOK REK, LEK, ROK and LOK Elegant and clear lined supply air diffusers for suspended ceilings. 06.6 REK, LEK, ROK and LOK Stylish supply air diffusers REK, LEK, ROK and LOK are designed for suspended ceilings

More information

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling

More information

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS SQUARE AND RECTANGULAR DIFFUSERS introduction The IC diffuser is a versatile form of air terminal offering the facility of multi directional throw patterns in a wide range of frame sizes. Each core style

More information

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES T SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES

More information

REK, LEK, ROK AND LOK

REK, LEK, ROK AND LOK REK, LEK, ROK AND LOK 5.3 Elegant and clear lined supply air diffusers for suspended ceilings. Lämmittäjänkatu 4 A, FI-008 HELSINKI, Finland Telephone +8 98 6600, Fax +8 0 98 6609 REK, LEK, ROK and LOK

More information

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers Incorporating V2.0 Product spec >>> > Series DJ - Drum jet diffusers Diffusers Drum jets (Premium) Recommended for: Wall, ceiling & duct Supply Overview Exceptional throw Throw completely adjustable Drum

More information

SDV Vane Swirl Diffusers

SDV Vane Swirl Diffusers SDV Vane Swirl Diffusers SDVSA Square plate vane swirl diffuser (angled slot) SDVCA Circular plate vane swirl diffuser (angled slot) SDVSB Square plate vane swirl diffuser (normal slot) SDVCB Circular

More information

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension Adjustable Curved Vane Diffusers ACDH ACDV Vanes are parallel to the width dimension Vanes are parallel to the height dimension Diffusers 2 Adjustable Curved Vane Diffusers ACDH / ACDV Introduction The

More information

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES 49-240 48LL1 49-280 49-480 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance. Linear bar grilles offer a choice

More information

Ventilation grille Model AL

Ventilation grille Model AL Ventilation grille AL Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Air diffuser system Model AUDIX -AW

Air diffuser system Model AUDIX -AW Air diffuser system Model AUDIX -AW Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

CornerAir. CornerAir. Active chilled beam

CornerAir. CornerAir. Active chilled beam Active chilled beam Description The active chilled beam is a one-way induction type air-conditioning unit that is designed for exposed installation, mounted directly under the ceiling against the corner.

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades

More information

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed

More information

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S PERFORATED FACE DIFFUSERS P SERIES P SERIES PERFORATED FACE DIFFUSERS P SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application:

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air ISSUE B, OCT 2009 Architectural Square Ceiling Diffusers UNI & AUNI Diffusers Product Overview - Uni Series Architectural Ceiling Diffusers Uni Series High Performance Square Face Round Neck The Model

More information

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CE SERIES CE SERIES LINEAR SLOT DIFFUSERS CE SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman

More information

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R 1/3/EN/4 Ventilation Grilles Types TRS-K TRS-R TRSE-R Contents Description Description 2 Constructions Dimensions TRS-K 3 Constructions Dimensions TRS-R 4 Constructions Dimensions TRSE-R 5 Installation

More information

DRUM SLOT DIFFUSER TYPE: RT350

DRUM SLOT DIFFUSER TYPE: RT350 TYPE: RT3 RT1 + RP301 98 RT2 + RP302 37 123 13.5 75.5 214 Application The RT3 drum slot diffuser is suitable for the supply and exhaust of cooled and warmed air in offices, shops, meeting rooms, etc. The

More information

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable

More information

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com PRODUCT BROCHURE Rectangular Displacement Diffuser RDW-FD smartemp.com DESCRIPTION The SMARTEMP Rectangular Displacement Diffuser, type RDW-FD (figure 1), produces a low velocity horizontal airflow pattern

More information

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation Halton CCE Adaptable active chilled beam for exposed installation Combined cooling, heating, and supply air unit for exposed installation Ideal solution for applications where good indoor environment,

More information

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS Wall air diffusers with discs for supply air and flush mounting QUICK FACTS Rotatable discs % flexible distribution pattern Cleanable Adjustable slot for enhanced capacity Simple adjustment Used together

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of sheet steel, with individually adjustable, horizontal blades Ventilation

More information

Ceiling diffuser 4DE

Ceiling diffuser 4DE Ceiling diffuser 4DE Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...

More information

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way) Fixed Bar Grills - Series G Description Caryaire Fixed Bar Grills are ideal for Supply as well as Return air, in both Cooling as well as Heating. It can be used in high side wall or ceiling applications.

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

Slot diffusers, Round duct diffusers. IMP Klima

Slot diffusers, Round duct diffusers. IMP Klima , Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING

More information

ADJUSTABLE SLOT DIFFUSER TYPE: SE800

ADJUSTABLE SLOT DIFFUSER TYPE: SE800 TYPE: SE800 Installation dimensions Construction with hanger brackets Construction without hanger brackets D C Application 7 E A 0 7 E A 0 The slot diffuser, type SE800 is used for the supply of cooled

More information

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles Incorporating V2.1 Product spec >>> > Series ECG - Egg crate grilles Grilles Egg crate Recommended for: Wall, ceiling & duct Extract Overview Industry standard extract grille Plastic egg crate core optional

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles with flat border construction also for continuous horizontal runs The new ventilation

More information

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise EYELASH DIFFUSERS E SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 71526 - Fax: 01707 71 527 - email sales@jprservices.co.uk

More information

Ceiling diffuser 4DF

Ceiling diffuser 4DF Ceiling diffuser 4DF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contens Description...3 Construction...

More information

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS Airodyne multi leaf volume control tampers have been specifically designed for use in air conditioning and ventilation system for volume,

More information

Ceiling impulse diffuser Model PIL

Ceiling impulse diffuser Model PIL Ceiling impulse diffuser Model PIL Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

LINEAR SLOT DUFFUSERS

LINEAR SLOT DUFFUSERS LINEAR SLOT DUFFUSERS CE SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL 2AA Tel: 010 12 - Fax: 010 1 2 - email sales@jprservices.co.uk

More information

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD) Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD) The DYRB is a quiet, ceiling-mounted supply air unit that consists of a nozzle diffuser, DYRH, and a plenum box, ATTD. The diffuser has adjustable

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV

More information

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25 Model Slot & Model Slot 25 Contents Introduction!!!!!! Page 3 Di"user Specification!!!! Page 4 Air Patterns!!!!!! Page 5 Flange Styles!!!!!! Page 6 Corner Sections!!!!! Page 7 Selection Procedure!!!! Page

More information

ADJUSTABLE PERFORATED AIR SUPPLY DIFFUSER TYPE: DC560S

ADJUSTABLE PERFORATED AIR SUPPLY DIFFUSER TYPE: DC560S Adjusting options: Construction: diffuser: steel, painted white (RAL 9) deflector plate: steel painted black (RAL 95) plenum: galvanised steel sheet with side entry, insulated or non-insulated only suitable

More information

ILO, OLO, OLE and OLOi

ILO, OLO, OLE and OLOi ILO, OLO, OLE and OLOi 09.16 Supply air diffusers and exhaust air devices for suspended and coffered ceilings, combining modern and stylish design, excellent air and sound properties, and uniquely easy

More information

series KLR Linear slot diffusers

series KLR Linear slot diffusers series Linear slot diffusers www.koolair.com 1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Product codes 5 2 Linear slot diffuser Description linear supply diffuser

More information

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa) DYBA is a quiet, ceiling-mounted supply air unit that consists of a nozzle diffuser, DYBH, and an insulated plenum box, ATTC. The nozzles of the diffuser produce a swirl pattern, which provides a highly

More information

USS - External Louvre. Halton USS. External Louvre

USS - External Louvre. Halton USS. External Louvre Halton USS External Louvre External louvre for air intake and exhaust to prevent rain, snow, leaf and animal ingress Rainwater ingress penetration efficiency of approx. 95% (USS/I) Operation based on special

More information

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles Incorporating V2.0 Product spec >>> > Series DD - Double deflection grilles Grilles Double deflection Recommended for: Wall, ceiling & duct Supply & extract Overview Enhanced functionality As per the name,

More information

Grilles Linear Grilles

Grilles Linear Grilles 1/1.1/B/2 Grilles Linear Grilles Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 763051 www.troxuk.co.uk e-mail: trox@troxuk.co.uk Contents Description

More information

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes: Perforated Ceiling Diffusers OPTIMA ceiling diffuser with perforated face, are recoended for heating, ventilating and cooling in centralized air conditioning systems. Perforated face diffusers, with 4-3-

More information

Wall and Ceiling Grille

Wall and Ceiling Grille September 14 Wall and Ceiling Grille Models SD, DD, EC, PG, G45, NVG, NB, GN, WB and GW Single and Double Deflection Fixed and Removable Core Eggcrate Perforated Grille 45 Fixed Blade Non Vision Bar Grilles

More information

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S SWIRL DIFFUSERS DWT SERIES DWT SERIES DISTRIBUTION PATTERNS & FIXING OPTIONS Application The DWT Series of swirl diffusers have been

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air

More information

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES COLMAN Air Distribution E N G I N E E R E D SWIRL DIFFUSERS DW SERIES DW SERIES A I R P R O D U C T S SWIRL DIFFUSERS DW SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application The DW type swirl diffuser

More information

FlowBar High Capacity Slot Diffuser

FlowBar High Capacity Slot Diffuser October 2016 FlowBar High Capacity Diffuser Model HT (High Throw) Model JT (Jet Throw) Features HT & JT 25mm, 38mm, 51mm, 63mm & 76mm s Ceiling or Sidewall Applications Modular or Continuous s Curved Sections

More information

ceiling swirl diffuser Model DQJA / DQJR

ceiling swirl diffuser Model DQJA / DQJR ceiling swirl diffuser Model DQJA / DQJR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face 2/1/EN/3 Slot Diffuser Type VSD15 with 15 mm wide diffuser face Contents Air Diffuser Discharge Characteristics (horizontal) 2 Description 3 Air Diffuser Discharge Characteristics (alternating) 3 Construction

More information

Slot diffusers for ceiling installation

Slot diffusers for ceiling installation X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger

More information

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for

More information

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser DHL HEPA terminal filter diffuser Low turbulent flow diffuser (LTF), also suitable for exhaust Installation flush to the ceiling, also suitable for wall installation A measurement access through the diffuser

More information

Grilles Linear Grilles

Grilles Linear Grilles T 1.1/1/EN/2 Grilles Linear Grilles for Walls, Floors, Doors, Rectangular and Circular Ducts TROX GmbH Telephone +9/28 /2 02-0 Telefax +9/28 /202-2 Heinrich-Trox-Platz e-mail trox@trox.de D-0 Neukirchen-Vluyn

More information

ceiling swirl diffuser DQJ

ceiling swirl diffuser DQJ ceiling swirl diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...

More information

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Linear Slot Diffusers Model Slot 20 and Model Slot 25 December 06 Linear Slot Diffusers Linear Slot Diffusers Model Slot and Model Slot 25 Features 1 to 8 Slots mm or 25mm Slot widths Ceiling or Sidewall Applications Modular or Continuous Lengths Curved Sections

More information

Halton Rex 600 RE6 - Adaptable active chilled beam

Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling. Well suited for spaces

More information

Small Format Circular Diffusers. Small format circular diffuse

Small Format Circular Diffusers. Small format circular diffuse Small Format Circular Diffusers Small format circular diffuse Diffusers Small Format Circular Diffusers Introduction The Waterloo diffuser has been designed for both supply and exhaust applications requiring

More information

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA Wall diffuser SVQC / Supply air unit SVQC + ATVA SVQC is a quiet supply air diffuser intended for mounting on a wall. The device is particularly

More information

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper Halton HFB Airflow Management Damper Control damper for different airflow and duct pressure control applications Pressure-independent operation Galvanised steel design Circular duct connection equipped

More information

Particle Filter Box Model FKF

Particle Filter Box Model FKF Particle Filter Box Model FKF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CD SERIES CD SERIES LINEAR SLOT DIFFUSERS QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman Moducel

More information