Cleanroom Filtration

Size: px
Start display at page:

Download "Cleanroom Filtration"

Transcription

1 Cleanroom Filtration

2 Cleanroom filtration Clean and sterile air in a cleanroom zone is provided by absolute filters. If even greater safety in terms of sterility is required, behind the absolute filter UV lamp is installed. Cleanroom classes are classified according to ISO (purity classes 1-8), U.S.F.S. 209 E and EU GMP standards (purity classes A,, C, D). The classes define max. permitted no. of particles per m³, no. of air changes, velocity, min. ceiling coverage by filters, filter type, exhaust air openings, positive pressure, temperature, humidity and other parameters. Icon legend: Fe PC Made out of / stainless steel sheet Polished surface Satin surface Made out of galvanized steel Made out of aluminum Powder coated / PVC coated Standard color G4 M5 F7 damper EPA filter Efficiency 99,999% MPPS according to standard G4 filter M5/M6 filter F7/F8/F9 filter Regulation damper Anodized aluminium Perforated steel Other on request Textile diffuser Filters sealed according to casing Easy filter insertion and replacement Filter saturation control Safe operator working environment ED light Air flow velocity above operation table between 0,15-0,30 m/s Mounted on ceiling and/or wall Requires filter with handle Cooling option 110 EC Easy to clean and disinfect Standard Ø110 opening for central light Removing unpleasant smells Standard filter height 48mm. Other heights on request EC fan 2 3

3 Operating room ventilation 4 5

4 EIPSO Operation ceiling SIP Operation ceiling a + 82 a b a b Casing x x EIPSO x 1800 x 450 EIPSO x 2400 x 525 EIPSO x 2600 x 530 Duct a x b 550 x x 150 (4 pcs.) 550 x x 200 (4 pcs.) 550 x x 200 (4 pcs.) EPA filter x 610 x x 305 x 69 (4 pcs.) 915 x 610 x x 610 x 69 (4 pcs.) 1220 x 610 x x 610 x 69 (4 pcs.) Air flow velocity (m/s) Air flow (m³/h) Casing x x SIP x 1400 x 450 SIP x 1800 x 450 SIP x 2400 x 450 SIP x 3000 x 450 Duct a x b 540 x x x x 200 (4 pcs.) EPA filter x 610 x x 610 x x 762 x x 915 x 69 (4 pcs.) Air flow velocity (m/s) Air flow (m³/h)

5 KIK Inclined outflow box OPR-CR Exhaust surgical grille M5 damper G a x b Casing x x Duct a x b Filter Number of filters (pcs.) Nominal x Frame +27 x +27 Installation opening -10 x -10 (G4) (M5) 225 x x x Δp max KIK x 410 x x x 610 x KIK x 410 x x x 610 x KIK x 410 x x x 610 x KIK x 410 x x x 610 x OPR-CR 275 x x x x x x x x x x x x x x x x x x x x x x x x

6 Ceiling filter box 10 11

7 FAC-V FAC-O Material (casing): Fe PC Material (casing): Fe PC Material (diffuser): Fe PC Material (diffuser): Fe PC Ø Ø x b 1 x l 1 x b 1 x l 1 Casing x x Connection Ø Casing frame b₁ x l₁ Filter Thickness Casing x x Connection Ø Casing frame b₁ x l₁ Filter Thickness 351 x 351 x x x x 351 x x x x 503 x x x x 503 x x x FAC-V 581 x 581 x x x FAC-O 581 x 581 x x x x 621 x x x x 621 x x x x 656 x x x x 656 x x x

8 FAC- FAC-Z Material (casing): Fe PC Material (casing): Fe PC Material (diffuser): Fe PC Material (diffuser): Fe PC 100 a x b a x b x b 1 x l 1 x b 1 x l 1 Casing x x Duct a x b Casing frame b₁ x l₁ Filter Thickness Casing x x Duct a x b Casing frame b₁ x l₁ Filter Thickness 351 x 351 x x x x x 351 x x x x x 503 x x x x x 503 x x x x FAC- 581 x 581 x x x x FAC-Z 581 x 581 x x x x x 621 x x x x x 621 x x x x x 656 x x x x x 656 x x x x

9 Diffuser plates DVS-K DEV-K DEU DEK-K ANP-K Technical information Camfil ternative Q max Δp max Q max Δp max Q max Δp max Q max Δp max 351 x 351 x x 503 x x 581 x x 621 x x 656 x x 351 x x 503 x x 581 x x 621 x x 656 x

10 Cleanroom ventilation 18 19

11 FFU-R Fe PC Filter fan unit - Raster FFU-S Fe Filter fan unit - Standalone PC EC EC G4 M5 F7 F9 G4 M5 F7 F FFU-R 1140 x 540 Silent Optimum asic FFU-R 1140 x 1140 Silent Optimum asic FFU-S 1200 x 600 Silent Optimum asic FFU-S 1200 x 1200 Silent Optimum asic Unit size 1132 x 534 x 440 Unit size 1132 x 1134 x 480 Unit size 1266 x 656 x 510 Unit size 1266 x 1266 x 550 Unit weight (kg) Unit weight (kg) Unit weight (kg) Unit weight (kg) Air volume 0.45 m/s Air volume 0.45 m/s Air volume 0.45 m/s Air volume 0.45 m/s Power 0.45 m/s (W) Power 0.45 m/s (W) Power 0.45 m/s (W) Power 0.45 m/s (W) Nominal power (W) Nominal power (W) Nominal power (W) Nominal power (W) Fan rotation speed (rev/min) Fan rotation speed (rev/min) Fan rotation speed (rev/min) Fan rotation speed (rev/min) Noise 1 [d] 45, ,5 2 [d] Noise 1 [d] ,5 2 [d] Noise 1 [d] [d] Noise 1 [d] [d]

12 FAK Fe PVC Absolute duct filter box FAR Absolute duct filter box with grille for wall mounting Material (casing): Fe PVC Material (grille): Casing x x Filter b x h x t Q max (13) (14) Δp max 309 x 309 x x 305 x Casing x x Filter b x h x t Q max (13) (14) Δp max 461 x 461 x x 457 x x 614 x x 610 x x 330 x x 305 x FAK 614 x 614 x x 610 x x 309 x x 305 x x 461 x x 457 x FAR 665 x 330 x x 305 x x 614 x x 610 x x 630 x x 610 x x 614 x x 610 x x 614 x max. 305 x 610 x max x 614 x max. 610 x 610 x max x 630 x x 610 x

13 FKV-P Rectangular duct bag filter box FKU Duct filter box with active coal Fe Fe G4 M5 F7 F9 PC PC Casing x x ag filter b x h x d (G4,M5) (F7,F9) (G4) (M5) (F7) (F9) Casing x x Cartridge number (pcs.) Filter b x h x t Air flow (m³/h) 300 x 150 x x 142 x x 200 x x 192 x x 250 x x 242 x x 309 x x 305 x x 300 x x 292 x FKV-P 600 x 300 x x 292 x x 350 x x 342 x FKU 309 x 614 x x 610 x x 400 x x 392 x x 500 x x 492 x x 614 x x 610 x x 500 x x 492 x 630 (x2)

14 SCU Fe PC Safe change unit PSCU Fe PC Prefilter safe change unit G4 F7 F Nominal x x Filter b x h x t 13 (standard) 13 (high flow) 14 (standard) 14 (high flow) Nominal x x Filter b x h x t (G4) 720 x 411 x x 305 x x 716 x x 610 x (F7) 720 x 411 x x 305 x x 868 x x 762 x x 411 x x 305 x SCU 720 x 716 x x 610 x PSCU 720 x 716 x x 610 x x 868 x x 762 x x 411 x x 305 x x 868 x x 762 x x 716 x x 610 x x 868 x x 762 x

15 VSPU Fe PC Validation scan port unit CRWPAN-E Exhaust panel Material (casing): Fe PVC Material (grille): b ød h Nominal x x Panel thickness t p Panel width Panel height Q max Duct ød Exhaust grille b x h 720 x 411 x x 716 x x 868 x x 411 x 250 CRWPAN x x x x 325 PSCU 720 x 716 x x 868 x 250 Panel thickness t p Panel width Panel height Q max Duct ød Exhaust grille b x h 720 x 411 x x 716 x x 868 x 250 CRWPAN x x x x

16 30 31

17 Address: Tel.: Fax.: Mail.: Web: Gradna 78A Samobor, Croatia info@klimaoprema.hr November, 2018.

Cleanroom Filtration

Cleanroom Filtration Cleanroom Filtration Cleanroom filtration Clean and sterile air in a cleanroom zone is provided by absolute filters. If even greater safety in terms of sterility is required, behind the absolute filter

More information

Air Zone. High Care. Cleanroom Filtration

Air Zone. High Care. Cleanroom Filtration Air Zone igh Care Cleanroom Filtration Cleanroom filtration Clean and sterile air in a cleanroom zone is provided by absolute filters. If even greater safety in terms of sterility is required, behind the

More information

Standard: for ceiling grid dimensions 1200 x 1200 mm, 1200 x 900 mm, 1200 x 600 mm. Other dimensions are available on demand.

Standard: for ceiling grid dimensions 1200 x 1200 mm, 1200 x 900 mm, 1200 x 600 mm. Other dimensions are available on demand. 5.1.6 Fan Filter Unit (FFU) Standard: for ceiling grid dimensions 1200 x 1200 mm, 1200 x 900 mm, 1200 x 600 mm. Other dimensions are available on demand. The FFU consists of the following components: -

More information

WALL VENTILATION GRILLES CBP

WALL VENTILATION GRILLES CBP WALL VENTILATION GRILLES CBP 01.10-01 CBP WALL VENTILATION GRILLES Description Designed for ventilation and air-conditioning installations, where control of air flow and direction of the air is required.

More information

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

Splash-proof Terminal HEPA Filter

Splash-proof Terminal HEPA Filter Splash-proof Terminal HEPA Filter Type GTS Overview The Splash-proofed Terminal HEPA Filter GTS is designed and tested to extract a Minipleat -Media Pack, available in different heights, with a new application

More information

Laminar ceilings, exhaust columns, exhaust grilles

Laminar ceilings, exhaust columns, exhaust grilles Laminar ceilings, exhaust columns, exhaust grilles 1 Table of Contents: 1. Laminar ceilings general information... 3 2. Laminar ceilings design and operation principles... 4 3. Parameters of air in the

More information

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION

More information

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

is with a variety of standard dimensions. Also our units can be custom engineered to any size. Bio Safety Cabinet biosafe TM is designed to provide personnel, environmental and product protection. Air flow is drawn around the operator into the front grille of the cabinet, which provides personnel

More information

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling

More information

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES TECHNICAL CHARACTERISTICS PP30 OVERVIEW : The PP 30F (rear connection) and PP 31F (lateral connection) are employed for the diffusion of air using

More information

Particle Filter Box FKU

Particle Filter Box FKU Particle Filter Box FKU Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

N O V E L T Y Diffuser with particulate filter class H13

N O V E L T Y Diffuser with particulate filter class H13 N O V E L T Y Diffuser with particulate filter class H13 NAF Atest Higieniczny: HK/B/1121/02/2007 NAF diffusers are intended to use in low- and mediumpressure ventilation systems. They are used in facilities

More information

External grilles USAV, USVN, USSV and SVN TECHNICAL DATA

External grilles USAV, USVN, USSV and SVN TECHNICAL DATA External grilles, U, and TECHNICAL DATA 2 External grilles, U, and U External grilles are used as covering grilles in air supply and exhaust openings. and U are moulded of aluminium. and are deep drawn

More information

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element Cleanroom systems Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. with pull-down outlet element DS 4178 E 01.201 Preliminary remarks Materials and designs As a rule, turbulent mixing ventilation is used

More information

Slot diffusers, Round duct diffusers. IMP Klima

Slot diffusers, Round duct diffusers. IMP Klima , Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS Slot diffusers LD-3, LD-4, LD-5 LD-3 LD-4 LD-5 SLOT DIFFUSERS Application: Slot diffusers are designed for air supply in rooms with floor to ceiling heights of 2.5

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades

More information

Lint separator FLARE

Lint separator FLARE Lint separator FLARE Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200 info@schako.de www.schako.de Contens Description...3 Construction... 3 Model...

More information

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES. 25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register

More information

WGA Long throw nozzle grille

WGA Long throw nozzle grille Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation...

More information

Taking small steps together, always ahead, towards a better world. Filtrasept. HEPA filter housings for ceilings and walls

Taking small steps together, always ahead, towards a better world. Filtrasept. HEPA filter housings for ceilings and walls Taking small steps together, always ahead, towards a better world Filtrasept HEPA filter hosings for ceilings and walls Filtrasept HEPA filter hosings for ceilings and walls APPLICATIONS Key Facts Clean

More information

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 Installation dimensions AS/GS120 AS/GS130 Application The grille type AS / GS is used for the supply and exhaust of cooled or heated air in facilities

More information

1. Description Design Front panels - vanes setting Flow directions Dimensions and weights... 8

1. Description Design Front panels - vanes setting Flow directions Dimensions and weights... 8 These technical specifications state a row of manufactured sizes and versions of whirling air outflow outlets VVDM 300, 400, 500, 600, 625 und 825 (further only outlets). It is valid for production, designing,

More information

NSDZ. Swirl diffusers with adjustable air control blades

NSDZ. Swirl diffusers with adjustable air control blades Swirl diffusers with adjustable air control blades NSDZ The diffusers NSDZ are intended to use in low- and medium-pressure ventilation systems. They allow for obtaining the swirl air flow and are especially

More information

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS SQUARE AND RECTANGULAR DIFFUSERS introduction The IC diffuser is a versatile form of air terminal offering the facility of multi directional throw patterns in a wide range of frame sizes. Each core style

More information

series Linear grilles

series Linear grilles series 30 Linear grilles www.koolair.com Series 30 1 CONTENTS Linear grilles 2 Linear floor grilles 3 Quick selection table 4 Example of selection 5 General dimensions 7 Accessories and mounting 10 General

More information

FRESH BREEZE FAN-FILTER UNIT TECHNICAL DATA

FRESH BREEZE FAN-FILTER UNIT TECHNICAL DATA FRESH BREEZE FAN-FILTER UNIT TECHNICAL DATA Fresh Breeze Fan-Filter Unit Range of Application... 3 Sizes... 3 Characteristics... 3 Fresh Breeze product line... 3 Areas of application... 3 Technical Data

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single

More information

Panel Finedust/HEPA Filter

Panel Finedust/HEPA Filter Panel Finedust/HEPA Filter Type GP Features HEPA efficiencies of 95% up to 99.99995% (@.3 m). Finedust efficiencies of 6% up to 98% ASHRAE. High quality micro fibreglass paper. Lowest initial pressure

More information

Round duct diffuser DBB-RR

Round duct diffuser DBB-RR Round duct diffuser DBB-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

AL/ST AIR GRILLES WITH MOBILE VANES. Intended use: AL/ST type are intended for using in low- and mediumpressure ventilation systems.

AL/ST AIR GRILLES WITH MOBILE VANES. Intended use: AL/ST type are intended for using in low- and mediumpressure ventilation systems. AL/ST AIR GRILLES WITH MOBILE VANES Intended use: AL/ST type are intended for using in low- and mediumpressure ventilation systems. Intended use Ventilation grilles AL/ST type are intended for using in

More information

1 of 5. Hepa Technologies Sdn. Bhd. AmAir 300X, RigiFil, AstroCel I. VariCel II

1 of 5. Hepa Technologies Sdn. Bhd. AmAir 300X, RigiFil, AstroCel I. VariCel II Hepa Technologies Sdn. Bhd. AmAir 300X, RigiFil, AstroCel I AmAir 300X AmAir 300X filters are constructed with AAF's totally unitized, double wall, moisture resistant die-cut beverage frame. The media

More information

Air distribution product

Air distribution product Air distribution product The company C.L.A. was established in 1975 as a manufacturer company of air conditioning system components. Among its customers: dealers, air handling units producers and fans

More information

ceiling swirl diffuser DQJ

ceiling swirl diffuser DQJ ceiling swirl diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...

More information

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,

More information

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1 X X testregistrierung Disc valves Type For supply air Circular disc valves with manually adjustable annular gap Nominal sizes 100, 125, 160, 200 mm Volume flow rate range 10 90 l/s or 36 324 m³/h Diffuser

More information

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE. GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE. GloveFAST Cyto Pharma/Aseptic Faster Isolator for Cytotoxic and Sterility test THE USER-FRIENDLY PRACTICAL

More information

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. CytoFAST Elite Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. OUR COMMITMENTS New technologies for a low environmental impact Fully aware that our choices of today will determine

More information

INDEX. Chapter3. air master. Linear Bar Grilles

INDEX. Chapter3. air master. Linear Bar Grilles Chapter3 INDEX A Linear bar grilles: 1. Supply linear bar grille...: ASLG...3.1 2. Supply linear bar register...: ASLR...3.2 3. Return linear bar grille...: ARLG...3.3 4. Return linear bar register...:

More information

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. CytoFAST Elite Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. OUR COMMITMENTS New technologies for a low environmental impact Fully aware that our choices of today will determine

More information

Lindab air filtration. Technical Catalogue

Lindab air filtration. Technical Catalogue Lindab air filtration Technical Catalogue ir filtration Overview Duct-filter units Duct pre-filter units KPF are designed to clean the air in air-conditioning and ventilating systems. Built-in filters

More information

FlowAir CATALOG.

FlowAir CATALOG. FlowAir CATALOG www.flowairfilters.com FPR Filter 2 The FPR is a Vcells Filter type. Especially designed to remove fine dust, smoke and bacteria. The FPR is suitable for air conditioning installations.

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles with flat border construction also for continuous horizontal runs The new ventilation

More information

Volume Flow Limiters Type VFL

Volume Flow Limiters Type VFL X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered

More information

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE. GloveFAST Cyto/Aseptic Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE. GloveFAST Cyto/Aseptic Faster Isolator for Cytotoxic and Sterility test COMMON FEATURES CONSTRUCTION Full body of the unit and

More information

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment Maximum Protection in Filter Systems CGF/CGG GEA Ceiling Air Outlets Data & Facts GEA Heat Exchangers / GEA Air Treatment Table of Contents Technical Description... 3 Application and Components... 3 Components...

More information

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS Ceiling mounted linear disc diffuser for supply air QUICK FACTS flexible spread pattern Facility for vertical spread Facility for simultaneous vertical/horizontal spread Large induction effect Suitable

More information

TECHINCAL DESCRIPTION BIO BAN

TECHINCAL DESCRIPTION BIO BAN TECHINCAL DESCRIPTION BIO BAN LAF CABINET ARTICLE DESCRIPTION CODE BIOBAN 48 00303400000 BIOBAN 72 00303500000 ST-[BIOBAN]_EN-0 Rev. 0 of 16/06/2010 Introduction Designed for the situation where is requested

More information

Particle Filter Box Model FKF

Particle Filter Box Model FKF Particle Filter Box Model FKF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of sheet steel, with individually adjustable, horizontal blades Ventilation

More information

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the

More information

GEA Clean Rooms. Modules with laminar air flow for ceiling installation GEA Fresh Heaven j^uu GEA Fresh Heaven j^uu=mltbo.

GEA Clean Rooms. Modules with laminar air flow for ceiling installation GEA Fresh Heaven j^uu GEA Fresh Heaven j^uu=mltbo. GEA Clean Rooms Modules with laminar air flow for ceiling installation GEA Fresh Heaven j^uu GEA Fresh Heaven j^uu=mltbo Data & Facts ÉåÖáåÉÉêáåÖ=Ñçê=~=ÄÉííÉê=ïçêäÇ db^=eé~í=bñåü~åöéêë Range of Application...

More information

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

INDEX. Chapter1 0. air master. Round Ceiling Diffusers air master Chapter1 0 INDEX A. Round ceiling diffusers 1. Fixed round ceiling diffuser...: ARDF...10.1 2. Round ceiling diffuser with adjustable pattern...: ARD...10.2 Standard sizes...10.3 Air pattern...10.3

More information

CG INLET CEILING. Inlet ceiling with the laminar discharge flow for operating rooms

CG INLET CEILING. Inlet ceiling with the laminar discharge flow for operating rooms CG INLET CEILING Inlet ceiling with the laminar discharge flow for operating rooms Pleasant climate controllable as required Economical operation due to the point protection principle Extremely low number

More information

MULTIDIRECTIONAL DIFFUSERS WITH EXTRACTABLE CONES

MULTIDIRECTIONAL DIFFUSERS WITH EXTRACTABLE CONES MULTIDIRECTIONAL DIFFUSERS WITH ETRACTABLE CONES OVERVIEW AND TECHNICAL DATA 4 Multidirectional 4-ways-diffusers in aluminium - dimensions from mm. 150 x 150 to mm. 600 x 600. MODEL A B D mm mm mm 150

More information

ceiling swirl diffuser Model DQJA / DQJR

ceiling swirl diffuser Model DQJA / DQJR ceiling swirl diffuser Model DQJA / DQJR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust 2 BERNER INTERNATIONAL Claire total At a glance CLAIRE TOTAL PRO CHEMISTRY Protection Shield The multiple award-winning Shield

More information

ACCESSORIES FOR DUCT FANS

ACCESSORIES FOR DUCT FANS FOR DUCT FANS Duct fan Clamp Filter box Silencer Electric heater Duct fans are mostly used in low-to medium-pressure ducted systems with additional components such as heaters, filter boxes, dampers, etc.

More information

Compact Finedust / HEPA Filter

Compact Finedust / HEPA Filter Compact Finedust / HEPA Filter Type G7 Overview The G7 filter is designed and tested to extract the smallest particles out of the air. The G7 series contains a fibreglass media pack in five (5) different

More information

Grilles & Diffusers. Series NV Non-vision grilles. Incorporating. Sight blocking design ensures privacy is maintained

Grilles & Diffusers. Series NV Non-vision grilles. Incorporating. Sight blocking design ensures privacy is maintained Grilles & Diffusers Incorporating Series NV Sight blocking design ensures privacy is maintained Perfect for areas like changing rooms Four models available including units to suit door mounting and dark

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

Total comfort control

Total comfort control Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data

More information

BP - Floor grilles E-04/07

BP - Floor grilles E-04/07 BP - Floor grilles 1-8.0-01.00-E-04/07 Floor grilles BP BP Floor grilles Versions - BP5 (deflection 0 ) - BP3 (deflection 15 ) - BP-RG (adjustable millimetrically) - BP-CTX (with counterframe) The supply

More information

WE GUIDE AIR LOUVERS

WE GUIDE AIR LOUVERS WE GUIDE AIR LOUVERS index >> SAND TRAP LOUVERS - STL / STLC 01-02 >> 2 INCH EXHAUST AIR LOUVERS - EAL - 2 03 >> 4 INCH EXHAUST AIR LOUVERS - EAL - 4 04 >> GRAVITY AIR LOUVERS - GAL 05 >> FRESH AIR LOUVERS

More information

Ceiling Swirl Diffuser DQJ

Ceiling Swirl Diffuser DQJ Ceiling Swirl Diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de contents Description...3 Advantages...

More information

Swirl Diffuser Model DQF

Swirl Diffuser Model DQF Swirl Diffuser Model DQF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Ventilation grille Model AL

Ventilation grille Model AL Ventilation grille AL Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Round duct grille Model KG-RR

Round duct grille Model KG-RR Round duct grille Model KG-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7 HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION Exflow 28 Technical Specification Page 1 of 7 TECHNICAL SUMMARY Terminal Unit size 12-3 ¼ x 12-3 ¼ x 23 ¾ Terminal Unit weight 3527

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey

More information

Krantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems

Krantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems DS 10 E 01.018 Preliminary remarks Where workplaces or production facilities have to be kept

More information

Floor Swirls Models BZD and SZD

Floor Swirls Models BZD and SZD July 09 Floor Swirls Floor Swirls Models BZD and SZD Features Model BZD Circular Floor Swirl Model SZD Circular Step Diffuser Grilles Diffusers Louvres Chilled Beams Ruskin Air Management Limited www.ruskinuk.co.uk

More information

For installation into ductwork

For installation into ductwork X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum

More information

Ducted HEPA filter units for highly sensitive areas

Ducted HEPA filter units for highly sensitive areas Ducted HEPA filter units for highly sensitive areas Without prefilter casing: Type F60 With prefilter casing: Type F70 Duct casing for installation into ductwork, with or without prefilter Double-groove

More information

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers Model : OSTL GI 341 Description: OPTIMA make Sand Trap Louver is used as pre-filter for the protection of air conditioning plants in area exposed to extreme levels of industrial pollution. It has a high

More information

Technical documentation

Technical documentation VM-PRO Mechanical volumetric flow control- Table of Contents Areas of application... 2 Useable volumetric flow ranges... 2 Function... 3 Processing... 3 Available sizes / -dimensions... 4 Accessories list

More information

MVF S.r.l. Via San Giovanni Bosco, Alessandria Tel Fax Web:

MVF S.r.l. Via San Giovanni Bosco, Alessandria Tel Fax Web: MV S.r.l. Via San Giovanni osco, 12-15121 Alessandria Tel. +39 131 68.73 - ax +39 131 56.334 Web: www.mvf.it -mail: info@mvf.it IN-LIN MIXD LOW DUT ANS ultra-quiet TD-SILNT Series TD-SILNT - MOD 16 TO

More information

series KLR Linear slot diffusers

series KLR Linear slot diffusers series Linear slot diffusers www.koolair.com 1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Product codes 5 2 Linear slot diffuser Description linear supply diffuser

More information

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8 Swirl diffuser DHV Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Ceiling Slot Diffuser Model DSX

Ceiling Slot Diffuser Model DSX Ceiling Slot Diffuser Model DSX Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

CornerAir. CornerAir. Active chilled beam

CornerAir. CornerAir. Active chilled beam Active chilled beam Description The active chilled beam is a one-way induction type air-conditioning unit that is designed for exposed installation, mounted directly under the ceiling against the corner.

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air

More information

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8. Fire safety products 1 / 8 DKISMA Systemair multicompartment rectangular smoke control dampers Resistance class EI120(v ew i o) S1500C mod AAmulti 1396 - CPR - 0112 Ordering codes Nominal dimensions Type

More information

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1) Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated, axial and roof fans, air handling units

More information

Type VSD35. Nominal length up to 1500 mm: one spigot

Type VSD35. Nominal length up to 1500 mm: one spigot Type VSD35 Nominal length up to 1500 mm: one spigot NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with 35 mm diffuser face (nominal width) and adjustable air control elements

More information

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Homepage > Producten > Luchtroosters > Lijnroosters > Pureline18 PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with

More information

Bench Top Extraction Arms

Bench Top Extraction Arms Bench Top Extraction Arms The Nederman BenchTop arms can be used in every type of environment, ranging from assembly stations, where solder fumes are extracted, to laboratories, where protection against

More information

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems Krantz Floor displacement outlet Q-B-DN 0 Air distribution systems DS 62 E 05. Construction design Preliminary remarks Floor displacement outlets are usually used where wall or plinth displacement outlets

More information

Ceiling diffuser 4DF

Ceiling diffuser 4DF Ceiling diffuser 4DF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contens Description...3 Construction...

More information

Slot diffusers for ceiling installation

Slot diffusers for ceiling installation X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13

More information

biolus BIO SAFETY CABINET

biolus BIO SAFETY CABINET 02 03 CHC LAB Biological Safety Cabinet www.chclab.com biolus BI SAFETY CABINET The biological safety cabinet perfectly eliminates the possibility of contaminated air outflow from inside cabinet. It provides

More information

series KFD-KLD Linear slot diffusers

series KFD-KLD Linear slot diffusers series KFD-KLD Linear slot diffusers www.koolair.com KFD-KLD Contents Linear slot diffusers KFD Selection tables KFD Dimensions 6 Connection system Linear slot diffusers KLD 8 Selection tables KLD 0 Dimensions

More information

Ceiling diffuser 4DE

Ceiling diffuser 4DE Ceiling diffuser 4DE Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...

More information