CAV-S Mechanical constant volume fl ow controller, steel

Size: px
Start display at page:

Download "CAV-S Mechanical constant volume fl ow controller, steel"

Transcription

1 Product description Function description Features Product description The mechanical constant fl ow volumetric controller CAV-S is made of galvanized steel and works independently without requiring additional energy. The housing design is available in round or rectangular CAV-S, round Functions description The central ball-bearing fl ap is moved by the air current. The control unit with control cam, spring and damper is attached to the outside of the galvanised sheet steel housing. The required volumetric fl ow is set in-factory. An adjustment of the volumetric fl ow at a later stage is possible (setting cam on housing). The control unit is protected with a cover. The controller can be assembled in any assembly position. CAV-S, rectangular For maintenance, service, retrofi tting, etc., inspection openings in suffi cient number and size must be provided onsite. Available connections are socket/socket, fl ange/fl ange or pipe/pipe. The constant volume fl ow controller CAV-S is suitable for supply and exhaust air fl ow control and the air volumes setpoints are step adjustable ( steps). To ensure accuracy, a suffi cient fl ow route should be maintained. Attention: The CAV-S is an adjusted controller working by the mechanism of action principle. Tampering with the controller, whether manually or mechanically, is prohibited. When a high volumetric fl ow setting has been selected, the damper leaf must never be closed manually. Otherwise, the control mechanism will be changed, resulting in a loss of control accuracy. The range of application must always be complied with. If the CAV-S is used beyond its allowed range of application, this will result in mechanical overload and thus in a loss of control accuracy. We would like to point out that to clean the stainless steel design, only suitable corresponding cleaning materials must be used! Features Housing design available in round or rectangular Self-acting constant flow regulator made of galvanized steel Suitable for supply or exhaust air volume control Mountable in any position Externally accessible adjuster for adjustable volume fl ow rate setpoints Flow range > 7:1 Control spring stainless steel Low friction damping element Differential pressure range Pa High accuracy of the adjusted volume flow rates of ± 5 %, based on VNOM Operating temperature 10 to +50 C Storage temperature -20 to +60 C Without auxiliary power Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice 1

2 Order code: Mechanical constant volume flow controller - round CAV S RR Type Diameter DN [mm] 80, 100, 125, 160, 200, 250, 315, Material case Galvanized steel Stainless steel Stainless steel S V2 V4 In- Outflow Pipe connections Remarks RR Pipe Pipe Steel and stainless steel FF Flange Flange Steel and stainless steel Acoustic cladding 0 without D with DD-coating 0 without DD with Rubber lip seal 0 without G with Ordering example: Mechanical constant volume flow controller, round Diameter 250, galvanized steel, without rubber lip seal, without DD-coating, without insulation shell, pipe/pipe. Make: SCHNEIDER Type: CAV-250-S RR Order code: Mechanical constant volume flow controller - rectangular CAV S Type Width B [mm] 200, 300, 400, 500, Height H [mm] 100, 150, 200, 250, 300, S Acoustic cladding 0 without D with DD-coating 0 without DD with Material case Galvanized steel Ordering example: Mechanical constant volume flow controller, rectangular Width=400 mm, Height=200 mm, Galvanized steel, without DD-coating, without insulation shell. Make: SCHNEIDER Type: CAV S Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice

3 Volumetric flow range CAV-S-round Volumetric flow range CAV-S-rectangular Nominal size V (m³/h) V [l/s] NW [mm] min. max. min. max Installation information To avoid unnecessary controller errors, the min. distances according to the following table / drawings must be observed. For combinations of several connection pieces or pieces with fi re dampers or silencers, the larger minimum distances must be observed. The volumetric fl ow controllers round and rectangular can be assembled with horizontal or vertical damper axis. V (m³/h) V [l/s] Width x Height min. max. min. max. B [mm] H [mm] Distance to: round rectangular Connection piece with bend 1 x D 1 x diagonal Other connection pieces: 2 x D 2 x diagonal branching or reducing piece, T-junction, etc. Fire damper 2 x D 2 x diagonal Silencer 2 x D 2 x diagonal Installation information CAV-S-round Distance to a connection piece with bend Installation information CAV-S-rectangular Distance to a connection piece with bend Distance to other connection pieces ( e.g. branching or reducing piece, T-junction, etc.), fi re damper or silencer Distance to other connection pieces ( e.g. branching or reducing piece, T-junction, etc.), fi re damper or silencer Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice 3

4 Nominal size Constant air volume flow controller - round Step adjustable volume flow setpoints [m³/h] NW [mm] Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step Width x Height Constant air volume flow controller - rectangular Step adjustable volume flow setpoints [m³/h] B [mm] H [mm] Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice

5 Flow generated noise CAV-S, round Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice 5

6 Radiaded noise CAV-S, round 6 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice

7 Radiaded noise CAV-S, round, with acoustic cladding Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice 7

8 Flow generated noise CAV-S, rectangular 8 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice

9 Flow generated noise CAV-S, rectangular Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice 9

10 Radiaded noise CAV-S, rectangular 10 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice

11 Radiaded noise CAV-S, rectangular Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice 11

12 Radiaded noise CAV-S, rectangular, with acoustic cladding 12 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice

13 Radiaded noise CAV-S, rectangular, with acoustic cladding Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice 13

14 Models and dimensions The CAV-S, rectangle is only delivered in right-hand design. If the control unit is required on the left-hand side, the CAV- S must be rotated by 180. Nominal size NW [mm] Available sizes CAV-S, round ØD [mm] L [mm] Available sizes CAV-S, rectangle Height H Width B x x x x x x x x x x x x x x x - x = available - = not available LR = Air fl ow direction No liability for misprint or modifi cations All rights reserved SCHNEIDER Tender specification CAV-S, round Mechanical volumetric fl ow controller type CAV-S, in round design, right-hand model, for constant volumetric fl ow regulation for duct connection to DIN EN Housing and control damper made of galvanised sheet steel, control housing made of plastic. Externally accessible adjusting for step adjustable fl ow rate setpoints. Differential pressure range 50 to 500 Pa, tolerance range typically ± 5 %, operating temperature 10 to +50 C. Product: SCHNEIDER Type: CAV-S Size: Tender specification CAV-S, rectangle Mechanical volumetric fl ow controller type CAV-S, in rectangle design, right-hand model, for constant volumetric fl ow regulation for duct connection to DIN EN Housing and control damper made of galvanised sheet steel, control housing made of plastic. Externally accessible adjusting for step adjustable fl ow rate setpoints. Differential pressure range 50 to 500 Pa, tolerance range typically ± 5 %, operating temperature 10 to +50 C. Product: SCHNEIDER Type: CAV-S Size: SCHNEIDER Elektronik GmbH Phone: +49 (0) 6171 / Industriestraße 4 Fax: +49 (0) 6171 / Steinbach Germany info@schneider-elektronik.de 14 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200

More information

Volumetric Flow Limiter VOLKOM

Volumetric Flow Limiter VOLKOM Volumetric Flow Limiter Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Field of

More information

Technical documentation

Technical documentation VM-PRO Mechanical volumetric flow control- Table of Contents Areas of application... 2 Useable volumetric flow ranges... 2 Function... 3 Processing... 3 Available sizes / -dimensions... 4 Accessories list

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

CAV controllers Type RN

CAV controllers Type RN 2.1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or return air in constant

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air 5/9.2/EN/6 Volume Flow Limiter Type VFL for insertion into air ducting The art of handling air Contents Description 3 Dimensions 3 Nomenclature 4 Technical data 4 Acoustic data 4 Installation notes 5 Order

More information

Volume Flow Limiters Type VFL

Volume Flow Limiters Type VFL X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered

More information

Mechanical mixing box MBM

Mechanical mixing box MBM Mechanical mixing box MBM Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...

More information

CONSTANTFLOW Volume Flow Controllers

CONSTANTFLOW Volume Flow Controllers 5/9.1/EN/8 CONSTANTFLOW Volume Flow Controllers for constant volume systems Type EN The art of handling air Contents Description Description 2 Application 3 Construction Dimensions Accessories 4 Dimensions

More information

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en X X testregistrierung Heat exchanger Type For the reheating of airflows in circular ducting Circular hot water heat exchanger for the reheating of airflows, suitable for VAV terminal units Type TVR and

More information

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

VAV TERMINAL BOXES TYPE: BA BT

VAV TERMINAL BOXES TYPE: BA BT Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500

More information

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK Type AK FOR LOW-LEAKAGE SHUT-OFF Circular shut-off dampers for shutting off volume flows in ventilation ducts

More information

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL Control units Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL The art of handling air Ventilation and air conditioning systems must fulfil complex and demanding requirements. With

More information

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400 Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Rectangular VAV terminal units for standard applications regarding the supply air or extract air control in variable air volume

More information

Round Duct System Model RR-Complete

Round Duct System Model RR-Complete Round Duct System Model RR-Complete Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...4

More information

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1 X X testregistrierung VAV terminal units Type Easy controller Compact controller Rectangular connection on the room end Circular connection on the fan end For supply air systems with demanding acoustic

More information

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K . X X testregistrierung VAV terminal units Type Easy controller Compact controller Circular connection on the fan end For extract air systems with demanding acoustic requi rements VAV terminal units for

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Shut-off dampers. Type AKK. For contaminated air PD AKK 1 X X testregistrierung Shut-off dampers Type Variant with circular spigot For contaminated air Plastic circular shut-off dampers for shutting off aggressive media volume flows in air conditioning systems

More information

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard applications regarding the supply air or extract air control in variable air

More information

VALVES WITH UM ELECTRIC ACTUATOR

VALVES WITH UM ELECTRIC ACTUATOR 505-507 VALVES WITH UM ELECTRIC ACTUATOR CHARACTERISTICS The 505+UM and 507+UM cast iron ball valves are dedicated to the automatic opening/shut-off of pipes carrying low pressure unloaded common fluids.

More information

Series 26d Ball Valve

Series 26d Ball Valve Stainless Steel Series 26d Ball Valve Application Tight-closing ball valve made of stainless steel for corrosive media, especially to meet high process requirements in chemical plants: Nominal sizes DN

More information

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN. Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN Type EN FOR THE PRECISE CONTROL OF NORMAL AND HIGH CONSTANT VOLUME FLOWS

More information

Technical information

Technical information 6-8 Application Rectangular NK and NL types are pressure-independent VAV and CAV air volume control terminals. The terminals are designed particularly for systems with large air volumes and duct sizes

More information

VALVES WITH UV ELECTRIC ACTUATOR

VALVES WITH UV ELECTRIC ACTUATOR 505-507 VALVES WITH UV ELECTRIC ACTUATOR CHARACTERISTICS The 505+UV and 507+UV cast iron ball valves are dedicated to the automatic opening/shut-off of pipes carrying low pressure unloaded common fluids.

More information

volumetric flow controller Model VRA-Q Smart

volumetric flow controller Model VRA-Q Smart volumetric flow controller Model VRA-Q Smart Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

VARYCONTROL VAV Dual Duct Terminal Boxes

VARYCONTROL VAV Dual Duct Terminal Boxes 5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk

More information

VAV Terminal Units SDS

VAV Terminal Units SDS VAV Terminal Units SDS VAV Terminal Units SDS STEKON SDS; controls the volume of conditioned air into an occupied space in response to a thermostat or Building Management System control signal with minimal

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV

More information

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Type AKK FOR CONTAMINATED AIR Plastic circular shut-off dampers for shutting off aggressive

More information

LEAKAGE CLASS ACHIEVED? Wöhler DP 700 LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS. The Measure of Technology GRAPHIC COLOR DISPLAY GRAPHIC

LEAKAGE CLASS ACHIEVED? Wöhler DP 700 LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS. The Measure of Technology GRAPHIC COLOR DISPLAY GRAPHIC LEAKAGE CLASS ACHIEVED? GRAPHIC COLOR DISPLAY COLOR DISPLAY GRAPHIC LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS The Measure of Technology Made in Germany Leakage Tester Just 3 entries to classify

More information

Round Duct System Model RR-Complete

Round Duct System Model RR-Complete Round Duct System Model RR-Complete Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...4

More information

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE Homepage > Products > Sound attenuators > Splitter sound attenuators > Type MSA Type MSA Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

More information

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL) Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The handling and installation

More information

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off

More information

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of

More information

4.1 Functional diagram FM100 fume hood monitor... 4 Functional description FM Interfaces Terminal diagram FM100...

4.1 Functional diagram FM100 fume hood monitor... 4 Functional description FM Interfaces Terminal diagram FM100... 2.0 LabSystem Fume hood monitors Table of contents Section Title Page 1.1 Introduction..................................... 2 2.1 Functional description............................. 2 2.1.1 Actual value

More information

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL) CODIFICATION CONSTRUCTION Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The

More information

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators

More information

Parts and characteristics

Parts and characteristics Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume

More information

CONTENT INTRODUCTION... 3 PRESSURE SENSORS INSTALLATION... 3 PIPES CONNECTION... 4 ELECTRICAL CONNECTION TO THE UNIT... 5

CONTENT INTRODUCTION... 3 PRESSURE SENSORS INSTALLATION... 3 PIPES CONNECTION... 4 ELECTRICAL CONNECTION TO THE UNIT... 5 CONTENT INTRODUCTION... 3 PRESSURE SENSORS INSTALLATION... 3 PIPES CONNECTION... 4 ELECTRICAL CONNECTION TO THE UNIT... 5 PRESSURE SENSORS SETTINGS... 6 VAV FUNCTION CALIBRATION... 8-2 - INTRODUCTION Variable

More information

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

NR series. Circular CAV air volume control terminals with system powered mechanical regulator series Circular CAV air volume control terminals Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 overview / dimensions 4-5

More information

7 Services Control and monitoring

7 Services Control and monitoring Control and monitoring 7 Services We are the only manufacturer of laboratory equipment who offers you fume cupboards and variable fume cupboard control all from one supplier. Benefit from our know-how

More information

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard

More information

DATA SHEET TB 26l. BR 26l, BR 26t, BR 26v, BR 26x Multi-port ball valve Ball valve in horizontal and vertical version. Application

DATA SHEET TB 26l. BR 26l, BR 26t, BR 26v, BR 26x Multi-port ball valve Ball valve in horizontal and vertical version. Application DATA SHEET TB 26l BR 26l, BR 26t, BR 26v, BR 26x Multi-port ball valve Ball valve in horizontal and vertical version Application Tight-closing multi-port ball valve made of stainless steel for aggressive

More information

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE TALE OF CONTENTS RETROFIT/YPASS TERMINAL UNITS RVE This retrofi t terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable volume systems and also

More information

Rotary Plug Valve BR 23e

Rotary Plug Valve BR 23e PTFE-lined Rotary Plug Valve BR 23e Application: PTFE-lined rotary plug valve for aggressive media, especially due to high demands in chemical plants: Nominal diameter: DN 25, DN 50, DN 80 and NPS1, 2,

More information

BR 26d Ball valve. Stainless Steel. Application: Versions: Special versions:

BR 26d Ball valve. Stainless Steel. Application: Versions: Special versions: Application: Stainless Steel BR 26d Ball valve Tight-closing Ball valve made of stainless steel for corrosive media, especially to meet high process requirements in chemical plants: Nominal sizes DN 15

More information

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers Type volume flow controllers series volume flow controllers General information Correct use Safety notes Area of application Operating modes Product description Installation Commissioning and wiring 5

More information

VAV controller. TROX Auranor Norge AS. Telephone Fax

VAV controller. TROX Auranor Norge AS. Telephone Fax GB0814 11.18 LØV-R VAV controller New regulator handles larger working area Low noise level Pressure independent Short overall length High measurement accuracy Can be installed directly in bend Flexible

More information

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/ 6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

Round duct grille Model KG-RR

Round duct grille Model KG-RR Round duct grille Model KG-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Krantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems

Krantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems DS 10 E 01.018 Preliminary remarks Where workplaces or production facilities have to be kept

More information

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

BR 20b Ball valve. PFA-lined. Application: Versions:

BR 20b Ball valve. PFA-lined. Application: Versions: PFA-lined BR 20b Ball valve Application: Tight-closing PFA-lined ball valve for (highly) corrosive media, especially with high process demands in chemical plants: Nominal sizes DN 25 to DN 200 Nominal

More information

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL. Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL Type KUL FOR INSTALLATION INTO DUCTWORK Non-return dampers prevent unwanted airflows

More information

Double regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25

Double regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25 The Oventrop Quality Management System is certified to DIN-EN-ISO 9001 Technical Information Application: Oventrop double regulating

More information

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02 GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV vertical outlet Issue 07/02 Roof fans made of plastic materials Series VRV with vertical outlet Usable in ventilation engineering of all branches

More information

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume

More information

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8 Swirl diffuser DHV Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

ceiling swirl diffuser Model DQJA / DQJR

ceiling swirl diffuser Model DQJA / DQJR ceiling swirl diffuser Model DQJA / DQJR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1 X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, galvanised sheet steel construction Circular silencers Type for the reduction of noise in the circular ducts

More information

Particle Filter Box FKU

Particle Filter Box FKU Particle Filter Box FKU Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

The Innovation Company. LTG Aktiengesellschaft. Technical Brochure. LTG Air Distribution. Highly-tight shut-off damper KLB

The Innovation Company. LTG Aktiengesellschaft. Technical Brochure. LTG Air Distribution. Highly-tight shut-off damper KLB Technical Brochure LTG Air Distribution Highly-tight shut-off damper KLB Notes Dimensions stated in this brochure are in mm. Dimensions stated in this brochure are subject to General Tolerances according

More information

Fan coil unit NBS 100/150

Fan coil unit NBS 100/150 Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3

More information

Drain ball valve BR 21a

Drain ball valve BR 21a PTFE - lined Drain ball valve BR 21a Application: Tight-closing PTFE-lined drain ball valve for corrosive media, especially for high process demand in chemical plants: Nominal sizes DN 50 to DN 150 Nominal

More information

Temperature Sensors. Information Sheet

Temperature Sensors. Information Sheet Temperature Sensors Information Sheet Itron temperature sensors are built in highest quality for various applications. A wide selection of direct and pocket installed sensors are a great complement of

More information

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide PELICANTM Wall Rectangular perforated wall air diffusers for supply air Quick facts Flexible air distribution pattern, easy to set Cleanable, removable damper Simple commissioning, fixed measurement tapping

More information

Hydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Hydrocontrol VFN nodular cast iron, PN 25 Double regulating and commissioning valves

Hydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Hydrocontrol VFN nodular cast iron, PN 25 Double regulating and commissioning valves Hydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Technical Information Application: Oventrop double regulating and commissioning valves Hydrocontrol VFC/VFR/VFN are installed in the pipework

More information

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK Installation and commissioning manual GB/en VAV terminal units VARYCONTROL LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK Read the instructions prior to performing any task! TROX GmbH Heinrich-Trox-Platz

More information

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS Homepage > Products > Control Systems > Variable volume flow control > VAV terminal units > Type TVLK Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS Plastic circular VAV terminal units

More information

Combustion gas damper EKO-JB

Combustion gas damper EKO-JB EKO-JB Description The EKO-JB combustion is a Class E6 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment wall or floor

More information

Particle Filter Box Model FKF

Particle Filter Box Model FKF Particle Filter Box Model FKF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics 654 3/-way and x 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Fast response times Space saving ( x 3/-way version) Type 654 can be combined with...

More information

MULTI-LEAF & SHUT-OFF DAMPERS Product Catalogue

MULTI-LEAF & SHUT-OFF DAMPERS Product Catalogue MULTI-LEAF & SHUT-OFF DAMPERS Product Catalogue 2 Table of contents Introduction 05 Square shut-off damper Product description: square shut-off damper Price list Test report according to DIN EN 1751 06

More information

For installation into ductwork

For installation into ductwork X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum

More information

Access Products. Download Wentyle Download AlnorCAM Buy via B2B

Access Products. Download Wentyle Download AlnorCAM Buy via B2B Access Products We reserve the right to make changes in the dimensions and technical data products due to their continuous improvement About the System About the System Access products, such as access

More information

LTG Air Distribution. Product Overview

LTG Air Distribution. Product Overview Product Overview LTG Air Distribution High-quality air flow control components with innovative technology. Unsurpassed in control precision and energy efficiency. LTG Aktiengesellschaft 1 LTG Aktiengesellschaft

More information

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems Krantz Floor displacement outlet Q-B-DN 0 Air distribution systems DS 62 E 05. Construction design Preliminary remarks Floor displacement outlets are usually used where wall or plinth displacement outlets

More information

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element Cleanroom systems Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. with pull-down outlet element DS 4178 E 01.201 Preliminary remarks Materials and designs As a rule, turbulent mixing ventilation is used

More information

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins HMR DUAL DUCT CABIN UNIT For passenger and crew cabins APPLICATIONS Halton HMR is pressure independent dual duct cabin unit. The airflow is continuously measured from the warm air spigot, as well as for

More information

FILLING AND CHECK VALVE

FILLING AND CHECK VALVE Filling valves characteristics Size Max. Flow (l/min.) R-114 DN-32 160 Max. Press. Opening ratio 3.6:1 Decompr. ratio Min pilot pressure Max pilot pressure Min. suction opening pressure Pilot volume (cm

More information

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω Actuators Technical data sheet Rotary actuator for control of volumetric flow without spring return Description Actuator for Volumetric flow and pressure control. Torque Motor Nominal Voltage Control Pressure

More information

Round duct diffuser DBB-RR

Round duct diffuser DBB-RR Round duct diffuser DBB-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6 Series 46 Self-operated Regulators Differential Pressure and Flow imiters Type 46-5 Type 46-6 Application Differential pressure and flow limitation for district heating systems with indirect connection,

More information

HML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating

HML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating HML Airflow Unit for Large Volumes with Centralized Airflow Heating Available as network compatible Halton HML is an airflow unit for large air volumes with centralized airflow heating. The unit can be

More information

Ceiling diffuser 4DE

Ceiling diffuser 4DE Ceiling diffuser 4DE Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...

More information

Mixing Box MBE / MBP

Mixing Box MBE / MBP Mixing Box MBE / MBP Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Installation...

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS TURBO-LUX 3 Orifice Plate Flowmeter FM, LPCB and VdS approved IMPRINT All rights reserved. Any reproduction or usage without written authorisation of MECON GmbH - even partial content

More information