GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02
|
|
- Kristopher Arron Mason
- 5 years ago
- Views:
Transcription
1 GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV vertical outlet Issue 07/02
2 Roof fans made of plastic materials Series VRV with vertical outlet Usable in ventilation engineering of all branches of industry High chemical resistivity by encapsulated motors and use of plastic materials Low noise emission Volumetric flow Pressure increase up to 4,200 m³/h up to 700 Pa Explosion-proof versions according to European Directive 94/9/EG (ATEX) Installation accessories such as roof bases, noise absorption bases etc. Wide range of electrical accessories upper housing shell half motor cover motor cooling air pipe motor knee repair switch impeller lower housing half shell rain water outlet flange intake socket Data specified herein are subject to alteration without prior notice. They will not be valid without written confirmation by the manufacturers.
3 Roof fans of plastic materials Series VRV Technical explanation APPLICATION Good corrosion resistance makes the type VRV Roof fans with vertical outlet suitable preferably for process exhaust systems in the chemical and pharmaceutic industries, for ventilation of laboratories, battery rooms, pickling plants, laundries, galvanic and agricultural units etc. The medium to be conveyed is taken in axially and blown out vertically with high speed. This allows good mixing with the environment. Certain demands of environmental control, such as German standard DIN 1946, part 7 (Room ventilation systems for laboratories), can thus be met. Roof fan VRV with sound absorbing base SDS TECHNICAL DESCRIPTION The fans are made in five nominal sizes with four different housing sizes. All parts getting into contact with the medium conveyed are made of PP (other materials upon inquiry). Plastic covers protect steel components against corrosion. The impellers curved backward are balanced dynamically according to ISO The housing is split horizontally to facilitate maintenance and cleaning of the fan and the pipeline connected. The driving motor is encapsulated completely so that contact with the medium conveyed is ruled out. Cooling air is fed in separately from outside. The fan is connected to pipelines or the matched accessories by a stable flange (dimensions according to MIETZSCH factory standard MWS 3030). CONDITIONS OF USE permissible ambient temperature C permissible temperature of volume flow C Higher temperatures are speed-dependent and permissible after the manufacturers agreement. Aggressive gases and vapours can be conveyed. The plastic materials used lead to good resistance to acids, lyes, alcohols, benzines etc. Even dust-laden media can be conveyed. Consultation with the manufacturers is necessary in cases of doubt. Working range The fan always operates in stable regime and can be applied even outside the characteristic range specified. Permissible inclination of fan axis (slope of roof) ±10 ACCESSORIES Splinter guard, assembly plate, assembly plate with non-teturn flap, sound-absorbing base, base for corrugated roofs, motor protction switch, pole changer, fan controls, frequency inverter EXPLANATION OF TYPE DESIGNATIONS VRV 160 / 711 W 1450 P 1 radial fan, vertical outlet nominal size (impeller intake diameter/mm) impeller type direct drive nominal speed rpm (higher speed of pole-changing motors abbreviations for special designs E TS P1 P2 EX DD = single-phase drive = with thermal winding protection (PTC resistor) = speed halving (Dahlander) such as 1450 P1 = 1,450/710 rpm = changeover to next smaller speed such as 1450 P2 = 1,450/950 rpm = with explosion-proof motor = delta motor connection for inverter regime with 3 x 230 V 03
4 PERFORMANCE p fa / Pa VRV 100 / 711 2,900 rpm Design features - Impeller with vanes curved backward - Welded plastic housing - Various fastening versions by flange - Drive motor encapsulated completely - Repair switch with auxiliary contact fastened on fan 1, ρ = 1,2 kg/m³ volumetric flow m³/h PRINCIPAL DIMENSIONS Performance sizes According to DIN , roof fans are specified by their pressure difference for free blowout: p fa = p bar - p ges S = p bar - p stats - r/2 * c S 2 In the desired working point, this pressure difference must be greater than the intake side pressure loss. Flange dimensions Ø D L = 8 x 7 Ø 160 D LK = 200 MOTOR VERSIONS (other motors, such as single-phase or Ex, upon inquiry) nominal motor nominal motor weight fan type speed motor type power current with motor L A3m L WA rpm kw A kg db(a) db(a) VRV 100/711 1, W ~ VRV 100/711 2, V/50 Hz W 2900 IP 55 VRV 100/711 2,900 3 ~ W 2900 P1 1,450 polechanging VRV 100/711 1, V/50 Hz W 1450 P1 710 IP L A3m = A - weighted sound pressure level at distance of 3 m L WA = A - weighted sound power level in duct 04
5 PERFORMANCE p fa / Pa VRV 160 / 711 2,900 rpm 1, ρ = 1,2 kg/m³ volumetric flow m³/h PRINCIPAL DIMENSIONS Design features - Impeller with vanes curved backward - Welded plastic housing - Various fastening versions by flange - Drive motor encapsulated completely - Repair switch with auxiliary contact fastened on fan Performance sizes According to DIN , roof fans are specified by their pressure difference for free blowout: p fa = p bar - p ges S = p bar - p stats - r/2 * c S 2 In the desired working point, this pressure difference must be greater than the intake side pressure loss. Flange dimensions Ø D L = 12 x 7 D LK = 290 Ø 250 MOTOR VERSIONS (other motors, such as single-phase or Ex, upon inquiry) nominal motor nominal motor weight fan type speed motor type power current with motor L A3m L WA rpm kw A kg db(a) db(a) VRV 160/ W ~ VRV 160/711 1, V/50 Hz W 1450 IP 55 VRV 160/711 2, W2900 VRV 160/711 2, W 2900 P1 1,450 3 ~ VRV 160/711 1,450 polechanging W 1450 P V/50 Hz VRV 160/711 1,450 IP W 1450 P L A3m = A - weighted sound pressure level at distance of 3 m L WA = A - weighted sound power level in duct 05
6 PERFORMANCE p fa / Pa VRV 200 / 712 2,900 rpm Design features - Impeller of PP, glass fibre-reinforced, with vanes curved backward - Welded plastic housing - Various fastening versions by flange - Drive motor encapsulated completely - Repair switch with auxiliary contact fastened on fan 200 1, ρ = 1,2 kg/m³ volumetric flow m³/h PRINCIPAL DIMENSIONS Performance sizes According to DIN , roof fans are specified by their pressure difference for free blowout: p fa = p bar - p ges S = p bar - p stats - r/2 * c S 2 In the desired working point, this pressure difference must be greater than the intake side pressure loss. Flange dimensions Ø D L = 12 x 7 D LK = 290 Ø 250 MOTOR VERSIONS (other motors, such as single-phase or Ex, upon inquiry) nominal motor nominal motor weight fan type speed motor type power current with motor L A3m L WA rpm kw A kg db(a) db(a) VRV 200/ W 710 VRV 200/ ~ W V/50 Hz VRV 200/712 1,450 IP W 1450 VRV 200/712 2, W2900 VRV 200/712 2, W 2900 P1 1,450 3 ~ VRV 200/712 1,450 polechanging W 1450 P V/50 Hz VRV 200/712 1,450 IP W 1450 P L A3m = A - weighted sound pressure level at distance of 3 m L WA = A - weighted sound power level in duct 06
7 PERFORMANCE p fa / Pa VRV 250 / ,450 rpm ρ = 1,2 kg/m³ volumetric flow m³/h PRINCIPAL DIMENSIONS Design features - Impeller with vanes curved backward - Welded plastic housing - Various fastening versions by flange - Drive motor encapsulated completely - Repair switch with auxiliary contact fastened on fan Performance sizes According to DIN , roof fans are specified by their pressure difference for free blowout: p fa = p bar - p ges S = p bar - p stats - r/2 * c S 2 In the desired working point, this pressure difference must be greater than the intake side pressure loss. Flange dimensions Ø D L = 12 x 9 D LK = 360 Ø 315 MOTOR VERSIONS (other motors, such as single-phase or Ex, upon inquiry) nominal motor nominal motor weight fan type speed motor type power current with motor L A3m L WA rpm kw A kg db(a) db(a) VRV 250/ W ~ VRV 250/ V/50 Hz W 950 IP 55 VRV 250/711 1, W 1450 VRV 250/711 1, W 1450 P ~ VRV 250/711 1,450 polechanging W 1450 P V/50 Hz VRV 250/ IP W 950 P L A3m = A - weighted sound pressure level at distance of 3 m L WA = A - weighted sound power level in duct 07
8 PERFORMANCE p fa / Pa VRV 315 / 712 1,450 rpm ρ = 1,2 kg/m³ volumetric flow m³/h PRINCIPAL DIMENSIONS Design features - Impeller of PP, glass fibre-reinforced, with vanes curved backward - Welded plastic housing - Various fastening versions by flange - Drive motor encapsulated completely - Repair switch with auxiliary contact fastened on fan Performance sizes According to DIN , roof fans are specified by their pressure difference for free blowout: p fa = p bar - p ges S = p bar - p stats - r/2 * c S 2 In the desired working point, this pressure difference must be greater than the intake side pressure loss. Flange dimensions Ø D L = 12 x 9 D LK = 444 Ø 400 MOTOR VERSIONS (other motors, such as single-phase or Ex, upon inquiry) nominal motor nominal motor weight fan type speed motor type power current with motor L A3m L WA rpm kw A kg db(a) db(a) VRV 315/ W ~ VRV 315/ V/50 Hz W 950 IP 55 VRV 315/712 1, W 1450 VRV 315/712 1, W 1450 P ~ VRV 315/712 1,450 polechanging W 1450 P V/50 Hz VRV 315/ IP W 950 P L A3m = A - weighted sound pressure level at distance of 3 m L WA = A - weighted sound power level in duct 08
9 Roof fans of plastic materials Series VRV Accessories Assembly plate MPL - VRV The assembly plate MPL-VRV is used for fastening the VRV Roof fans on flat roofs and foundations. The flange with nominal diameter DN is employed for fan fastening. Fastening elements and a seal are in the range of delivery. Diameter D1 on the connection side is smooth. The plate should be supported on its entire face. Careful sealing toward the roof is important. Special designs: with non-return flap with rain water edge base height H = 300 mm pipe connection (with welded socket) design for pitched roof. optional with non-return flap optional with rain water edge Special dimensions and variants for particular roof designs and foundations upon inquiry. Material: PPs (PVC) Designation: MPL - VRV D N - D 1 fan type type of D N D 1 a H L assembly plate mm mm mm mm mm VRV 100/711 MPL-VRV MPL-VRV VRV 160/711 MPL-VRV MPL-VRV VRV 200/712 MPL-VRV MPL-VRV VRV 250/711 MPL-VRV MPL-VRV VRV 315/712 MPL-VRV MPL-VRV Sound-absorbing base SDS - VRV The sound-absorbing base is used for damping the sound power in the suction line. The absorber material is incombustible according to DIN 4102 and covered with glass wool and perforated plates. The flange with nominal diameter DN is employed for fan fastening. Fastening elements and a seal are in the range of delivery. Connecting diameter D1 is designed as a socket. The base should be supported on its entire face. Careful sealing toward the roof is important. Special designs: with non-return flap with rain water edge with sealing plate or rain water collar with cable bushing design for pitched roof. Special dimensions and variants for particular roof designs and foundations upon inquiry. optional with sealing plate (for roof insulation) socket (welded on) optional with rain collar (for roof insulation) Material: PPs (PVC) Designation: SDS - VRV D N - D 1 fan type base type DN D1 Da a H De mm mm mm mm mm db VRV 100/711 SDS-VRV SDS-VRV VRV 160/711 SDS-VRV SDS-VRV VRV 200/712 SDS-VRV SDS-VRV VRV 250/711 SDS-VRV SDS-VRV VRV 315/712 SDS-VRV SDS-VRV
10 Series VRV Outlet silencer ASD Dimensions / Noise absorption The circular silencer welded on the upper housing half shell leads to noise absorption on the outlet side which is 7 db better than the standard design. fan type D N H ges D e mm mm db VRV 100/711 - ASD VRV 160/711 - ASD VRV 200/712 - ASD VRV 250/711 - ASD VRV 315/712 - ASD Material: PPs (PVC) Example how to order: Roof fan VRV 160 and 1,450 rpm with outlet silencer: VRV 160 / 711 W ASD 10
11 No. Quantity Designition Individual price EUR Overall price EUR Roof fan of plastic material vertical outlet Mietzsch Lufttechnik - series VRV radial impeller with vanes curved backward of PPs (PVC) or glass fibre-reinforced PP, balancing quality G 6.3 according to ISO 1940, fly-mounted on motor shaft split conical housing with vertical inlet and outlet, made of PPs (PVC), intake nozzle shaped aerodynamically fastening with assembly plate MPL or sound-absorbing base SDS with flange direct drive by standard motor encapsulated against flowing medium, version for single-phase AC or three-phase current, two-, four-, six- or eight-pole, polechanging optionally motor optionally with thermal winding protection (PTC resistor) repair switch with auxiliary contact, fastened on fan safety requirements according to VDMA VRV _ / 71 _ W - - nominal size impeller type nominal speed special design material volumetric flow : m 3 /h pressure increase free outlet : Pa temperature of medium conveyed : C motor power : kw voltage / frequency : V Hz nominal currant : A power input : kw fan speed : rpm noise level L A3m : db(a) weight : kg connection diameter : mm Accessories and special equipment 1) Assembly plate MPL - VRV Assembly plate MPL-VRV with non-return flap Sound-absorbing base SDS - VRV Outlet silencer ASD Motor protection switch Other elements 1) delete as applicable 07/02
12 Our program of products and services Radial fans of plastic material Direct and belt drive up to about m³/h and Pa Explosion-proof fans according to ATEX for zone 1 and zone 2 Roof fans of all-plastic design with many assembly accessories Special fans Duct built-in devices, mobile radial fans Systems for central ventilation in housing construction, special-purpose fans, exhaust elements, controlling and regulating devices Complete plants of plastic materials for industry and craft, laboratory and process exhaust systems, air cleaning plants Ventilation components of plastic material Pipes, ducts, fittings, flaps, gas-tight shutoff flaps, exhaust air heads, deflector hoods, exhaust hoods, filter cases, volume flow controller etc. Droplet eliminators and moisteners Gas washers for separation of gaseous dangerous substances, dust/gas separators Heat exchangers for recovery of heat from moist and aggressive exhaust air Containers of PVC, PP, PE for liquids endangering water, according to water resources regulations, containers of composite design PVC/GFRP, PP/GFRP Controlling and regulating elements and systems Switches, motor protection devices, speed controllers, frequency inverter, fan controls, flow supervision Special designs of plastic materials Devices, linings etc. Engineering performances Planning, calculation, and design, ventilation measurement on standardized test stands, low and high temperature test in company-own climatic test chambers Rectangular and cylindrical silencers, silencing casings in corrosion-proof design Großenhain Moritzburg Dresden-Neustadt exit BERLIN COTTBUS BAUTZEN Dresden-Hellerau exit Dresden-Wilder Mann exit Hubertusplatz FRANKFURT A.M. CHEMNITZ LEIPZIG DRESDEN N O Trachenberger Platz Dresden-city center GmbH Lufttechnik Dresden Großenhainer Straße Dresden Telefon: (0351) FAX: (0351) mietzsch@mietzsch.de Internet
GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 10/17
GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV vertical outlet Issue 10/17 Roof fans made of plastic materials Series VRV with vertical outlet Usable in ventilation engineering of all branches
More informationGmbH Lufttechnik Dresden USER INFORMATION RADIAL FANS. SERIES VRE direct driven. Issue 09/06
GmbH Lufttechnik Dresden USER INFORMATION RADIAL FANS SERIES VRE 560 direct driven Issue 09/06 s Series VRE VRE 560 direct driven Application in all s of ventilation High chemical resistivity by the use
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationSmall centrifugal fans made of plastic
Small centrifugal fans made of plastic durable application-optimised wide range of variants 2 Small centrifugal fans made of plastic Index Small centrifugal fans made of plastic HF R 75-16 D and HF R 110-18
More informationPowerful centrifugal fans for universal use: The product ranges TEM and REM
Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which
More informationCentrifugal fan with highly efficient EC drive motor
Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany
More informationPowerful centrifugal fans for universal use: The product ranges TEM and REM
Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL
More informationData sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design
Data sheet Page: 1 / 5 Operating data Requested flow rate Operating data determined for maximum inlet pressure Requested developed head 15.00 m Pumped medium Ambient air temperature 20.0 C Fluid temperature
More informationCMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C
BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured
More informationData sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m
Data sheet Item no.: 2600 Page: 1 / 5 Operating data Requested flow rate 40.00 m ³/h Actual flow rate 40.00 m ³/h Requested developed head 68.00 m Actual developed head 68.00 m Pumped medium Water Efficiency
More informationCircular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/
6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn
More informationData sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.
Data sheet Item no.: 1900 Page: 1 / 5 Operating data Pumped medium Water Actual flow rate 72.19 m ³/h Operating data determined for maximum inlet pressure Actual developed head 70.26 m Clean water Efficiency
More informationMegaBox Product-specific information
MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions
More informationV.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes
Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings,
More informationGmbH Lufttechnik Dresden. User information RADIAL FAN SERIES VRE direct-driven. Edition 11/17
GmbH Lufttechnik Dresden User information RADIAL FAN SERIES VRE 0 direct-driven Edition 11/17 series VRE 0 direct-driven For use in all areas of ventilation technology High chemical resistance through
More informationSMART Application Structure Acoustics s n fa f o o R
Application The SMART fans are designed for general ventilation of buildings. They are meant for forwarding dry air of maximum temperature +60 C, and dustiness not exceeding 0,3 g/m³, without viscous,
More informationExplosion and flame-proof cast iron electric motors
Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting
More informationThe Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular
More informationROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE
ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4
More informationFANS WITH ENERGY EFFICIENT EC TECHNOLOGY
FANS WITH ENERGY EFFICIENT EC TECHNOLOGY ECOFIT ETRI THE AIR MOVEMENT GROUP Rosenberg Ventilatoren GmbH Maybachstr. 1/9 D-74653 Künzelsau-Gaisbach Fon +49 (0)7940 / 142-0 Fax +49 (0)7940 / 142-125 www.rosenberg-gmbh.com
More informationData sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design
Data sheet Page: 1 / 7 Operating data Requested flow rate Requested developed head Pumped medium Ambient air temperature 20.0 C Fluid temperature 20.0 C Fluid density 998 kg/m³ Water Clean water Not containing
More informationMODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC
MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC ... 3... 4 3000 rpm 50 Hz / 3600 rpm 60 Hz... 4... 5... 7 Modular pump / motor systems... 7 Materials...........................................................
More informationEco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors
Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)
More informationExport Pricelist. Extraction rail type AS Exhaust rail, pipe connections. Extraction rail type AS Exhaust rail, Pipe Connections
Export Pricelist Extraction rail type AS 175 2 Exhaust rail, pipe connections Extraction rail type AS 290 3 Exhaust rail, Pipe Connections Extraction rail type AS 440 4 Exhaust Rail, Pipe Connections Assembly
More informationThermoplastic Vertical Sump Pump Type ETL
ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33.7 99-0 Fax +49 (0) 57 33.7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Thermoplastic Vertical Sump Pump Type ETL dry-running
More informationSeries VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h
SOUND-INSULATED KITCHEN FAN Series device. The impeller is mounted on the motor shaft and is balanced statically and dynamically. The motor has F class motor winding insulation and ingress protection rating.
More informationVertical Sump Pump Type ETL
Vertical Sump Pump Type ETL»dry running safe«technical data Flow rate Q up to 220 m 3 /h Head H up to 55 m Submersion depth 500 or 750 mm Suction extension up to 1800 mm Materials limits of use PP up to
More informationIN-LINE RECTANGULAR FANS IRB / IRBS IRB
IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning systems. They
More informationCalculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas!
Page 1 Standard Series Size: 3 Air flow volume Calculation of external available Pressure [m³/h] 3 4 5 55 6 65 7 75 8 9 1 11 12 1. Criterion flow velocity (Ref. 2 C) Do not design units in conditions acc.
More informationRadial roof fans - SMART-UL. Application. Stylistics. Structure. Efficiency adjustment. Acoustics
Application SMART-UL fans have been designed for general ventilation of buildings. They are meant for forwarding the dry air of maximum temperature 140 F, and dustiness not exceeding 0,3 g/m³, without
More informationShort casing. Long casing (L version) Commercial premises
CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled
More informationCYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS
- ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate
More informationExplosion and flame-proof single phase electric motors
Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz Types of mounting
More informationCentrifugal Immersion Pumps
Centrifugal Immersion Pumps FLUX Centrifugal Immersion Pumps Quality that sets standards. Manufactured at our main plant, these ranges of immersion pumps are the result of extensive product and process
More informationLEF/MEF LEX/MEX ATEX versions
Fan LEF/MEF 250-630 - LEX/MEX ATEX versions GEOVENT centrifugal fan LEX and MEX with closed backward curving B-wheel and directly driven flange motor. The fan is used for extraction within the industry
More informationSpecifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).
Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and
More informationType MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE
Homepage > Products > Sound attenuators > Splitter sound attenuators > Type MSA Type MSA Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE
More informationMixed Flow Roof Fans (RMH)
Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard
More informationROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series
asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air
More informationLiquid ring vacuum pumps with magnetic coupling
Liquid ring vacuum pumps with magnetic coupling LPH 75320, LPH 75330, LPH 75340 Pressure range: Suction volume flow: 33 to 1013 mbar 485 to 1615 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum
More informationDuct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code
Tubes and ox Fans Duct Fans - ESTOC EC Range Features Sizes from 55 to 6 mm diameter ir flow 19, m /h (4. m /s) Static pressures up to 84 Pa Maximum temperature up to 6 C Controllable external rotor motors
More informationCGT Series Adjustable Pitch Fans
AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel
More informationSERIES R - MD MOR & GOR
SERIES R - MD MOR & GOR CHARACTERISTICS OPTIONS Aluminium alloy construction Surface protection treatment (anodising, only for ATEX 2 versions) Available in monoblock execution (MOR) and with coupling
More informationVARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.
VARIO VARIO Separation of fine dust particles The VARIO series is particularly suitable for separation of fine dust. The VARIO units are of modular construction in order to meet different requirements,
More information1. Description Design Front panels - vanes setting Flow directions Dimensions and weights... 8
These technical specifications state a row of manufactured sizes and versions of whirling air outflow outlets VVDM 300, 400, 500, 600, 625 und 825 (further only outlets). It is valid for production, designing,
More informationIn-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.
In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V
More informationsupplied in Form (B) configuration. Airflow over Impeller- Motor.
CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,
More informationVent-Axia Sabre Sickle Roof Fans (VSR)
Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,
More informationCENTRIFUGAL IMMERSION PUMPS
CENTRIFUGAL IMMERSION PUMPS FLUX CENTRIFUGAL IMMERSION PUMPS QUALITY THAT SETS STANDARDS Manufactured at our main plant, these ranges of immersion pumps are the result of extensive product and process
More informationAXIAL FANS Catalogue CN0050C01 May 2008
ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced
More informationVORTICENT C E RANGE Centrifugal fans
NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,
More informationCGT Series Adjustable Pitch Fans
AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel
More informationAXIAL FANS Axis / Tubo OPERATION MANUAL
TUBO-M AXIS-QA AXIS-Q AXIS-QR AXIS-F AXIS-QRA AXIAL FANS Axis / Tubo OPERATION MANUAL Axis / Tubo www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements
More informationMAJAX-2 GENERAL SPECIFICATION
MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed
More informationUD and UC Gear pump unit
1-19-EN for SKF CircOil or hydraulic lubrication systems General Information The UC and UD gear pump units are vertically or horizontally arranged units that are used in hydraulic or circulating-oil lubrication
More informationVAV terminal units. Type TVM. For dual duct systems PD TVM 1
X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings
More informationExplanation of AR Series Ventilator Products. Fan type code D S AR AE
Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction
More information1 AIR HANDLING UNIT TYPE AIR ACCESS 75
SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting
More informationBall Valve C 110. PVC-U PP PVDF - wafer flange socket end DIN-flange. Ball. Advantages. Ball seat. Application. Sealings. Utilisation.
ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Ball Valve C 110 PVC-U PP PVDF - wafer flange
More information4 pole insulated conductor rails UNILIFT-ULA 35A, 50A, 80A, 100A
2 Table of contents General information... 4 Elements of the conductor rail supply line... 4 Innovative connection method... 5 Technical properties... 6 Construction of the line section... 6 Line section...
More informationCircular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1
X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, galvanised sheet steel construction Circular silencers Type for the reduction of noise in the circular ducts
More informationBPF. Centrifugal Plug Fans
BPF Centrifugal Plug Fans Introduction INTRODUCTION Plug Fans S&P - THE COMPANY Soler & Palau was founded in 1951 in Ripoll (Spain) and since this date has become one of the world s leading companies engaged
More informationFEATURES & BENEFITS UPON REQUEST
ErP 27 IDUSTRIAL CETRIFUGAL FAS WITH VERY HIGH PRESSURE APPLICATIO High pressure industrial centrifugal fans with backward curved impeller, suitable for exhausting clean or slightly dusty air. They can
More informationVARYCONTROL VAV Dual Duct Terminal Boxes
5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk
More informationData sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.
Data sheet Page: 1 / 5 Operating data Requested flow rate 160.00 m³/h Actual flow rate 159.85 m³/h Operating data determined for maximum inlet pressure Actual developed head 20.96 m Requested developed
More informationHEPTADRY. Dry screw pumps. Optimum ultimate pressure. Absolutely oil-free. Cool-running.
HEPTADRY Dry screw pumps. Optimum ultimate pressure. Absolutely oil-free. Cool-running. HEPTADRY Dry screw pumps. Optimum ultimate pressure. Absolutely oil-free. Cool-running. With HeptaDry, Pfeiffer Vacuum
More informationCAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)
X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered
More informationRoof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER
Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER Roof Extract Fans Ventilation Hoods Smoke Extract Fans DV DLH ER Summary... Seite Roof Extract Fans DV Product review... Summary data sheet...
More informationUnobox units with backward curved centrifugal impellers
Unobox Fans Unobox units with backward curved centrifugal impellers Type Code UNO 67-450 -4 E W Unobox Box size 50=500mm ; 67=670mm 80=800mm ; 102=1020mm Impeller diameter Number of poles D - Three Phase
More informationShort casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles
CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Additional Information Standard air direction: form (B) configuration (Impeller over ). models description: incorporated an "L" after blade pitch angle. E.g.
More informationAxial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.
xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof
More informationTechnical brochure. LTG Fans. Tangential fans Type GA 25 / TA 40. Impeller diameter 25 mm / 40 mm.
Technical brochure LTG Fans Tangential fans Type GA 25 / TA 40 Impeller diameter 25 mm / 40 mm www.ltg.net LTG Process Air Technology LTG Fans LTG Filtration Technology LTG Humidification Technology Content
More information2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50
2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, 10-50 (2652) (2655) 2 or ball valve Pneumatic actuator Compact design Visual position indicator Types 2652/2655 can be
More informationROOFMASTER STEF-HT ROOF FAN
fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation
More informationCRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS
ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire
More informationKrantz. Floor displacement outlet Q-B-DN 200. Air distribution systems
Krantz Floor displacement outlet Q-B-DN 0 Air distribution systems DS 62 E 05. Construction design Preliminary remarks Floor displacement outlets are usually used where wall or plinth displacement outlets
More informationVertical Immersion Pump VTP - BBF
MB / General VTP centrifugal pumps in block design (BBF) correspond to the system of two-pipe pumps. Basically these immersion pumps are single-level immersion pumps with vertical axis the main components
More informationMechanical mixing box MBM
Mechanical mixing box MBM Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...
More informationROOFMASTER STEF-ATEX ROOF FAN
Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...
More informationMixed Flow Roof Fans (RMH)
Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard
More informationCategory 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence
Explosion proof fans General Systemair explosion proof fans have been developed to be used in effective supply and exhaust air systems allocated to category 2 (zone 1) and category 3 (zone 2) in explosion
More information400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity
400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,
More informationASV Eccentric Pumps Type F and Type L
ASV Eccentric Pumps Type F and Type L»self-priming - dry running capable«technical data Type F Type L Flow rate Q up to 1,8 m 3 /h up to 5,2 m 3 /h Head H up to 25 m up to 25 m Suction height H max. 5
More informationVKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.
Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories,
More informationCentrifugal Fans RZR belt driven. Issue 2.5 EN August 2013
Centrifugal Fans RZR belt driven Issue 2.5 EN August 2013 1 AMCA Nicotra Gebhardt S.p.A. (Italy) certifies that ADH-E fans of the E0, E2, E4, E6 and E7 versions, from sizes 01 to 05, RDH-E fans of the
More informationBifurcated Case Axial Fans (BIFA)
Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient
More informationThreaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35 WIKA Data Sheet TE 60.03 Applications Machinery, plant and tank construction Energy
More informationLenze. Drives with worm gearboxes 52.
6 887 Lenze Drives with worm gearboxes 5. Lenze Drive Systems GmbH, Postfach 0 5, D-76 Hameln, Site: Groß Berkel, Hans-Lenze-Straße, D-855 Aerzen, Phone ++9 (0) 55 8-0, Telefax ++9 (0) 55 8- E-Mail: Lenze@Lenze.de
More informationCNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX
NA-NB NA-NB ENTRIFUGAL FANS STANDARD TEMPERATURES AND EX PRODUT FATS PRODUT The centrifugal fans type NA and NB are robust and versatile fans of the single-inlet type with backward-curved blades. APPLIATION
More informationRLM EVO High Performance - Plug Fans Impeller with true airfoil blades
RLM EVO High Performance - Plug Fans Impeller ith true airfoil blades Issue 1 1 RLM EVO Ready for the next generation Overall static RLM EVO 211 213 215 ErP-Guideline 9/125/EG We have accelerated impeller
More informationChemical Magnetic Pumps with PTFE/PFA lining ATEX- and FDA compliant
Chemical Magnetic Pumps with PTFE/PFA lining ATEX- and FDA compliant Highly corrosionresistant pumps for absolute aggressive liquids and dangerous liquids. Energy-efficient pumps and chemical pumps Sustainable
More informationQuality wins through!
Components for biogas Quality wins through! Offer benefits Harvest profits with Eisele More than 25 years of experience with Biogas plants The robust and powerful pumps and submersible mixers of EISELE
More informationOperating instructions
Operating instructions Type TEKA filtoo TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72 E-Mail:
More informationTGT Series Adjustable Pitch Fans
CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot
More informationACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans
Hacer título más resumido ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans Construction Casing The fan casings are manufactured from heavy gauge galvanised sheet steel and
More informationCentrifugal pumps. made of Polypropylene and PVDF for transferring aggressive media like acids and alkalies
Vertical and horizontal centrifugal pumps www.jesspumpen.com Centrifugal pumps made of Polypropylene and PVDF for transferring aggressive media like acids and alkalies Vertical centrifugal pumps of the
More informationThread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell
Electrical Temperature Measurement Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell WIKA Data Sheet TE 60.15 Applications T Machinery, plant and tank construction T Energy
More informationPAB Atex-certified centrifugal pumps
1 6036 EN PAB Atex-certified centrifugal pumps Technical data Delivery rate Q max = 305 l/min Delivery head H max = 20 m Temperature range 0 C to +60 C Quality Management DIN EN ISO 9001: 2008 Environmental
More informationBoiler Feed Booster Pump YNK. Type Series Booklet
YNK Type Series Booklet Legal information/copyright Type Series Booklet YNK All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any
More information