Filter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ

Size: px
Start display at page:

Download "Filter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ"

Transcription

1 Filter Bestellnr. (ohne Filterelement) Typ Innengewinde G Code Spin-on Filter Serie HF HF62.2-B-GE-XA-DA-XB-DA HHT HF62.2-B2-GE-XA-DA-XB-DA 3/4 HHT HF62.2-B17-GE-XA-DA-XB-DA HHT HF62.3-B-GG-XA-DA-XB-DA HHT HF62.3-B2-GG-XA-DA-XB-DA 1 1/4 HHT HF62.3-B17-GG-XA-DA-XB-DA HHT HF62.4-B-GH-XC-DA HHT HF62.4-B2-GH-XC-DA 1 1/2 HHT HF62.4-B17-GH-XC-DA HHT HF62.5-B-GH-XD-DA HHT HF62.5-B2-GH-XD-DA HHT HF62.5-B17-GH-XD-DA HHT / HF62.5-BSAE311/2" HF62.5-B SAE HF62.5-B2SAE311/2" HHT HF62-5-B17SAE311/2" HHT3151 Spin-on Filterelement Bestellnr für Filtergehäuse Typ max. empfohlener Durchfl uss für Saugfi lter l/min max. empfohlener Durchfl uss für Rücklauffi lter HF62.2 HEK AS-FG3-B?? HEK AS-FG l/min Code HEK AS--B 15 4 HHC HEK AS--B 15 4 HHC HEK AS--B 2 5 HHC HEK AS--B 25 6 HHC HEK AS--B 3 7 HHC HEK AS--B 2 5 HHC HEK AS--B 2 5 HHC HEK AS--B 25 6 HHC HEK AS--B 3 7 HHC HEK AS--B 35 8 HHC HEK AS-FG3-B?? HHC HEK AS--B 6 12 HHC HEK AS--B 6 12 HHC HEK AS--B 7 14 HHC HEK AS--B 6 18 HHC HF62.3 HEK AS--B HHC HEK AS--B 8 14 HHC HEK AS--B 8 14 HHC HEK AS--B 9 16 HHC HEK AS--B 1 19 HHC HEK AS--B HHC

2 SUCTION AND RETURN IN LINE FILTERS SERIES HF 62 - HF 625 Edition: 2/9.21 Replaces: HF 62 1 T E The filters HF 62 series are specifically designed to be connected on the suction or in the return line of the hydraulic circuit and provide versatility to safeguard the circuit components from contaminating particles. The filters HF 625 series are suitable for working pressure up to 25 bar. ADJUSTABLE SETTING BY-PASS ALE DIFFERENTIAL CONTROL OF THE CLOGGING ALUES COMPLETE FILTER MATERIALS FLUID COMPATIBILITY CONFORMING TO ISO 2943 FLOW RANGE MAX. WORKING PRESSURE TESTING PRESSURE BURST PRESSURE OPERATING TEMPERATURE Head Aluminum Bowl Steel Seals Buna - iton With fluid (HH-HL-HM-HR-H-HG), and water emulsion (HFAE-HFAS) use filters with Buna seals. With riference to With water - glycol (HFC) ISO 6743/4 ask for anodizing treatment. With synthetic fluid (HS-HFDR-HFDU-HFDS) use filters with iton seals min. 2 [l/min] max. 4 [l/min] 7 [kpa] 7 bar (HF62) - 25 [kpa] 25 bar (HF625) 1 [kpa] 1 bar (HF62) - 5 [kpa] 5 bar (HF625) 15 [kpa] 15 bar (HF62) - 75 [kpa] 75 bar (HF625) With Buna seals [ C] With iton seals [ C] FILTER ELEMENTS End cap - Inner tube Zinc plated steel. With water - glycol ask for tin treatment. MATERIALS Steel Filter media Cellulose Micro-fibre glass REMOAL RATING Conforming to ISO ELEMENT COLLAPSE PRESSURE RATING Conforming to ISO [kpa] 4 bar 1 [kpa] 1 bar (only for micro-fibre glass or steel wire mesh HE K46 elements) IKRON S.r.l Lemignano di Collecchio (PR) - Italy ia C. Prampolini, 2 Telephone: (+ 39) Fax (+ 39) ikron@casappa.com 3-2

3 TECHNICAL DATA STANDARD FILTER ARRANGEMENT AND INDICATORS PRESSURE/ACUUM GAUGE M INDICATOR FOR FILTERS MOUNTED ONLY ON RETURN LINE ISUAL DIFFERENTIAL INDICATOR D ELECTRICAL INDICATOR E ISUAL INDICATOR RETURN SUCTION Filter type A B C D E F G Ø H I L M N O P Q R S mm mm GAS-BSPP mm mm mm mm mm mm mm mm mm mm mm mm mm mm 46 G 3/ , ,5 HF HF HF G 1 1/ HF ,5 For working pressure up to 25 bar HF G 3/ HF , , ,5 Di /9.1 Replaces:

4 TECHNICAL DATA Di /9.1 Replaces: 6.98 Filter type A B mm mm HF HF The standard filter is furnished arranged for the indicators (XC) G 1/ 8 with plug (DA). RETURN RETURN SUCTION Filter type A B mm mm HF HF The standard filter is furnished arranged for the indicators (XD) G 1/ 8 with plug (DA). SUCTION LINE POSITION INDICATOR CODE PRESSURE/AC. GAUGE M ISUAL ELECTRICAL E RETURN LINE POSITION INDICATOR CODE PRESSURE/AC. GAUGE M ISUAL ELECTRICAL E ISUAL DIFF. INDICATOR H EL. - ISUAL DIFF. INDIC. L See drawing and note on the side page. ISUAL DIFF. INDICATOR H RETURN RETURN SUCTION EL. - ISUAL DIFF. INDIC. L 3-2

5 HOW TO ORDER A COMPLETE FILTER HF AS - MS9 - B2 - GE B - XA - GA - M 1 Filter type CODE See tables HF Filtering surface CODE Standard AS 3 Degree of filtration CODE 1 m] Micro-fibre glass 25 [ m] Micro-fibre glass 6 [ m] Steel wire mesh 9 m] Steel wire mesh MS9 125 [ m] Steel wire mesh MS125 1 [ m] Cellulose 25 [ m] Cellulose 4 By-pass valve CODE Setting 2 [kpa]; [bar] (suction only) B2 Setting 17 [kpa]; 1,7 [bar] (return only) B17 None B 5 Inlet port CODE Thread GAS (BSPP) G 3/4 GE G 1 1/4 GG G 1 1/2 GH Element type A B Ø C HE K HE K HE K HE K mm GAS - BSPP mm G 3/4 96 G 1 1/4 128 For working pressure up to 25 bar HE K HE K Seals CODE Buna B iton 7 Indicators arrang. CODE None XN On the head - right XA On the head - left XB Standard for HF62-4 only XC Standard right and left HF62-5 only XD 8 Dim. Indicat. ports CODE Thread GAS (BSPP) G 1/8 GA G 1/8 WITH PLUG DA G 1/4 GB G 1/4 WITH PLUG DB G 1/2 GD G 1/2 WITH PLUG DD Holes on the wall for ind. D FP FILTERING ELEMENTS - TECHNICAL DATA G 3/4 96 HOW TO ORDER A REPLACEMENT ELEMENT 9 Indicators CODE None G Pressure/vacuum gauge - rear M isual indicator Electrical indicator E isual differential indicator (for HF HF62-3 only) D isual differential indicator (for HF HF62-5 only) H El.-visual differential indicator (for HF HF62-5 only) L Standard On request HE K AS - MS9 - B 1 Element type CODE See table HEK Filtering surface CODE Standard AS 3 Degree of filtration CODE 1 [ m] Micro-fibre glass 25 [ m] Micro-fibre glass 6 [ m] Steel wire mesh 9 m] Steel wire mesh MS9 125 [ m] Steel wire mesh MS125 1 m] Cellulose 25 m] Cellulose 4 Seals CODE Buna B iton Standard On request Di /9.1 Replaces:

6 SUCTION AND RETURN FILTERS SERIES HF PRESSURE DROP CURES The pressure drop for filters series HF 62 on suction line is bar max; the pressure drop for filters series HF 62 and HF 625 on return has to be between and,4 bar. 1) The by-pass pressure drop is directly proportional to fluid specific gravity and it s irrelevant to determine the total pressure drop. By-pass valve s pressure drop HF 62-2 / HF By-pass valve s pressure drop HF , 4,5 4, B17 5, 4,5 4, 3, 2,5 2, 3, 2,5 2, B17 1,5 1,,5 B2 1,5 1,,5 B2, , ,6 By-pass valve s pressure drop B2 HF 62-4 / HF62-5 5, By-pass valve s pressure drop B17 HF 62-4 / HF62-5 1,4 1,2 4, 1,,8 B2 3, B17,6 2,,4 1,, ,

7 2) The housing s pressure drop is determined by the sum of the inlet and outlet port dimension.,5 Housing s pressure drop HF 62-2 / HF 625-2,4,3, ,5 Housing s pressure drop HF 62-3,4,3, ,8 Housing s pressure drop HF 62-4 / HF 62-5,7,6,5,4,3,

8 3) The filter element s pressure drop is determined by standard media and AS surface, they have been calculated experimentally and thy are valid for clean elements. Filter element s pressure drop HE K45-2- / HE K Filter element s pressure drop HE K45-2- / HE K ,5,5, ,4,3 2.18, ,1, Filter element s pressure drop HE K45-2- / HE K Filter element s pressure drop HE K45-2- / HE K ,5,4,18, ,3, ,14,12,1,8,6,4 2.18, Filter element s pressure drop HE K45-2- / HE K Filter element s pressure drop HE K45-2-MS9 / HE K46-2-MS9-6-,18,18,16,16,14,14,12,1, ,12,1, MS9,6,6,4, ,4, MS Filter element s pressure drop HE K45-2-MS125 / HE K46-2-MS Filter element s pressure drop HE K ,18, ,16,4,14,12,1,8, MS125,3 3.21,4,1, MS

9 Filter element s pressure drop HE K Filter element s pressure drop HE K ,5,5,4,4, , ,1 3.21, Filter element s pressure drop HE K Filter element s pressure drop HE K ,18,18,16,16,14, ,14,12,1,8,6 3.21,1,8, ,4,2,4, Filter element s pressure drop HE K45-3-MS9-13- Filter element s pressure drop HE K45-3-MS ,18,16,14,12,1,8,6,4, MS MS ,18,16,14,12,1,8,6,4, MS MS

10 Bocca Ingresso Inlet Port FILTRI HF / FILTERS HF LINEA DI ASPIRAZIONE / SUCTION LINE G 3/4" 15 G 3/4" 2 G 1"1/4 6 G 1"1/4 8 G 1"1/2 15 G 1"1/2 16 G 1"1/2 15 G 1"1/ MICRON ASS./ABS. 25 MICRON ASS./ABS. 1 MICRON NOM. HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF Peso Filtro Filter Weight (Kg) 1 1,2 1,9 2 3,4 5,3 5,4 Bocca Ingresso Inlet Port G 3/4" 25 G 3/4" 3 G 1"1/4 85 G 1"1/4 1 G 1"1/2 19 G 1"1/2 21 G 1"1/2 19 G 1"1/ MICRON NOM. 6 MICRON MICRON HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF MS9-MS125 HF HF MS9-MS125 HF MS9-MS125 HF MS9-MS125 HF MS9-MS125 HF MS9-MS125 HF MS9-MS125 HF MS9-MS125 Peso Filtro Filter Weight (Kg) 1 1,2 1,9 2 3,4 5,3 5,4 3-2

11 Bocca Ingresso Inlet Port FILTRI HF / FILTERS HF LINEA AL RITORNO / RETURN LINE G 3/4" 4 G 3/4" 5 G 1"1/4 12 G 1"1/4 14 G 1"1/2 28 G 1"1/2 3 G 1"1/2 28 G 1"1/2 3 1 MICRON ASS./ABS. 25 MICRON ASS./ABS. 1 MICRON NOM. HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF Peso Filtro Filter Weight (Kg) 1 1,2 1,9 2 3,4 5,3 5,4 Bocca Ingresso Inlet Port G 3/4" 6 G 3/4" 7 G 1"1/4 18 G 1"1/4 19 G 1"1/2 34 G 1"1/2 36 G 1"1/2 34 G 1"1/ MICRON NOM. 6 MICRON MICRON HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF MS9-MS125 HF HF MS9-MS125 HF MS9-MS125 HF MS9-MS125 HF MS9-MS125 HF MS9-MS125 HF MS9-MS125 HF MS9-MS125 Peso Filtro Filter Weight (Kg) 1 1,2 1,9 2 3,4 5,3 5,4 3-2

Filter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ

Filter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ Filter Bestellnr. (ohne Filterelement) Typ Innengewinde G Code Spin-on Filter Serie HF 620-1000 HF620.20-B00-GE-XA-DA-XB-DA HHT03084-1050 HF620.20-B02-GE-XA-DA-XB-DA 3/4 HHT03163-1100 HF620.20-B17-GE-XA-DA-XB-DA

More information

Filter. Rücklauffilter 3-Loch Serie HF 502. Bestellnr. Innengewinde G. Code. Typ. (ohne Filterelement)

Filter. Rücklauffilter 3-Loch Serie HF 502. Bestellnr. Innengewinde G. Code. Typ. (ohne Filterelement) Filter Bestellnr. (ohne Filterelement) Typ Innengewinde G Code Rücklauffilter 3-Loch Serie HF 52 3-4- HF52-.6-GD-B-H-Z-XD-DA /2 HHRK62 3-4-5 HF52-2.77-GD-B-H-Z-XD-DA /2 HHRK22 3-4- HF52-2.77-GE-B-H-Z-XD-DA

More information

In line high pressure filters. HF 735 series

In line high pressure filters. HF 735 series In line high pressure filters HF 735 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

THE IMPORTANCE OF AN EFFICIENT FILTRATION

THE IMPORTANCE OF AN EFFICIENT FILTRATION In line high pressure filters HF 745 / HF 748 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the

More information

In line high pressure filters. HF 725 series

In line high pressure filters. HF 725 series In line high pressure filters HF 725 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

THE IMPORTANCE OF AN EFFICIENT FILTRATION

THE IMPORTANCE OF AN EFFICIENT FILTRATION Tank mounted return line filters HF 554 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

In line high pressure filters. HF HF 761 series

In line high pressure filters. HF HF 761 series In line high pressure filters HF 76 - HF 761 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the

More information

D e s c r i p t i o n

D e s c r i p t i o n D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHB series filters are designed for pressure line applications where manifold mounting is a specific requirement. The manifold type filters are designed to integrate onto manifold

More information

THE IMPORTANCE OF AN EFFICIENT FILTRATION

THE IMPORTANCE OF AN EFFICIENT FILTRATION Tank mounted return line filters HF 57 / HF 575 / HF 578 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants

More information

SPIN-ON FILTER - LOW PRESSURE LINE

SPIN-ON FILTER - LOW PRESSURE LINE SERIES MSH SPIN-ON FILTER - LOW PRESSURE LINE Maximum working pressure 5 psi Flow rate to 8 GPM D e s c r i p t i o n MSH working pressure of 5 psi, with a peak pressure This filter MSH series utilises

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm SERIES SF2-250 SUCTION FILTER Flow rate to 45 gpm D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows

More information

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 12 bar Flow rates to 3 l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for

More information

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHP series filters are designed for high pressure line applications and are suitable for in-line installation. Continued research and development on both the filter bodies and the

More information

SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm

SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm SERIES SF2-5 SUTION FILTER Flow rates to 225 gpm D e s c r i p t i o n 5 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 225 gpm and filtration from

More information

10 Hydraulic Filters

10 Hydraulic Filters 1 Hydraulic Filters Introduction.... 1- HF65 Series.... 1-9 HF66 Series.... 1-15 HF67 Series.... 1-21 HF68 Series.... 1-1 Dual Spin-On Assembly.... 1-5 Introduction Hydraulic Filtration Systems Cummins

More information

10 Hydraulic Filters

10 Hydraulic Filters 1 Hydraulic Filters Introduction................................... 1-3 HF65 Series................................. 1-9 HF66 Series................................ 1-15 HF67 Series................................

More information

D e s c r i p t i o n

D e s c r i p t i o n e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed (MPH) or totally immersed into

More information

FPK04 Max Flow: 100 gpm (379 lpm)

FPK04 Max Flow: 100 gpm (379 lpm) HIGH PRESSURE FILTERS In-Line Cartridge Filters Working Pressures to: 4350 psi 30,015 kpa 300 bar Rated Static Burst to: Flow Range To: 9135 psi 63,000 kpa 630 bar 100 gpm 379 lpm Features The T-type ported

More information

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:

More information

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181 Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:

More information

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n RF2 96 Maximum pressure 20 bar F l o w r a t e s t o 4 5 5 l / m i n Filter housing (Materials) Filter body: luminium over: Nylon Valve: Nylon - Steel nti-emptying valve: Steel Pressure Working pressure:

More information

Fluid Cooling Industrial COLW Series

Fluid Cooling Industrial COLW Series Fluid Cooling Industrial COLW Series 0916 COPPER & STEEL CONSTRUCTION Performance Notes Ideal for independent cooling and filtering of system oils Utilizes a high efficient EK series shell & tube (finned

More information

The range of products is completed by a number of accessories, including:

The range of products is completed by a number of accessories, including: ACCESSORIES The range of products is completed by a number of accessories, including: Foot brackets, which serve to support the motor-and-pump unit in the event that the selected electric motor does not

More information

HIGH PRESSURE FILTERS Series HF2P

HIGH PRESSURE FILTERS Series HF2P HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,

More information

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:

More information

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data Filter housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:

More information

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass COMPONENTS RC MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2002) Max working:

More information

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1.5.1): F1-XD4/63/1: 1 bar (15 psi) F1-XD16/25/4: 8 bar (12 psi) Housing Burst (acc. to

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request) HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to

More information

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T 3.10.5.1) Burst 330 bar (4800 psi) (acc. to NFPA T 3.10.5.1) Housing

More information

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass COMPONENTS RB MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2) Max working: 0 kpa

More information

HYDRAULIC PUMPS, MOTORS & FILTERS

HYDRAULIC PUMPS, MOTORS & FILTERS HYDRAULIC PUMPS, MOTORS & FILTERS Our passion for high performance in hydraulic drives us. Constant evolution and a passion for hydraulics; this has been Casappa s strategy, a privately owned company that

More information

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters Return fi lters series Maximum pressure up to bar - Flow rate up to 15 l/min 193 Return fi lters GENERAL INFORMATION Technical data Return filter Maximum pressure up to bar - Flow rate up to 15 l/min Filter

More information

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS Low Pressure Filters Low pressure filters are the most common type of filter found in hydraulic circuits used most often in return line applications. Low Pressure Filters Donaldson low pressure filters

More information

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T ) HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Housing

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:

More information

HYDRAULIC PUMPS, MOTORS & FILTERS

HYDRAULIC PUMPS, MOTORS & FILTERS HYDRAULIC PUMPS, MOTORS & FILTERS Our passion for high performance in hydraulic drives us. Constant evolution and a passion for hydraulics; this has been Casappa s strategy, a privately owned company that

More information

SRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction

SRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar Technical Data Filter Elements Main Operating pressure up to 1000 kpa (10 bar). Static pressure testing up to 1500 kpa (15 bar). Back pressure

More information

AIR FILTERS AND FILLER BREATHERS FA3 / FB1 / FB2 / FT series ACCESSORIES HYDRAULIC SYMBOL

AIR FILTERS AND FILLER BREATHERS FA3 / FB1 / FB2 / FT series ACCESSORIES HYDRAULIC SYMBOL ACCESSORIES AIR FILTERS AND FILLER BREATHERS FA3 / FB1 / FB2 / FT series The air breather filters are integral part of the filtration within the hydraulic system, as they retain the environment contamination

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to

More information

FHA 051 Working pressure 6000 psi

FHA 051 Working pressure 6000 psi 6 SRIS Working pressure 6000 psi Style S Style Style T Style D Style V Style Z D.I. 7 8 Technical data Filter body (Materials) Head: Steel (chemical heat treatment) Housing: Steel (chemical heat treatment)

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Features MF Filters are manufactured with an aluminum head. MF, MFD, MFDS Series Spin-On Filters Choice of NPT, SAE straight thread O-ring boss, BSPP, and SAE 4-bolt flange porting to allow easy installation

More information

Terresolve Biodegradable Products High Performance Environmentally Safe

Terresolve Biodegradable Products High Performance Environmentally Safe Terresolve Biodegradable Products High Performance Environmentally Safe Terresolve Technologies 9609 Jackson Street, Mentor, Oh, 44060 800-661-3558 www.terresolve.com Environmental Products Have Been Used

More information

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

Filtering elements differential collapsing pressure tested in compliance with ISO 2941: DESCRIPTION Many years of in-field experience have shown the necessity of more and more efficient controls on the contamination level of hydraulic fluids and fuels. With this goal uppermost in its mind,

More information

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Return Line Filter HF4R up to 450 l/min, up to 10 bar Return Line Filter HF4R up to 450 l/min, up to 10 bar 9" 18" 27" 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international regulations.

More information

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW FILTERS HYDRAULIC DIVISION - Suction filters SD TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW SPARE PARTS ORDERING INFORMATION DINSIONS OF

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 2500 l/min, up to 315 bar 30 60 110 140 160 240 280 330 500 660 1.x 660 2.x 990 2.x 1320 2.x 1320 3.x 2640 3.x 3960 3.x 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING

More information

HPK04 Max Flow: 120 gpm (454 lpm)

HPK04 Max Flow: 120 gpm (454 lpm) HIGH PRESSURE FILTERS In-Line Cartridge Filters Working Pressures to: 6000 psi 41,380 kpa 413.8 bar Rated Static Burst to: Flow Range To: 17000 psi 117,300 kpa 1173 bar 120 gpm 454 lpm Features The high

More information

Pressure Filter DF...K P, DF...M P, Flange Mounted

Pressure Filter DF...K P, DF...M P, Flange Mounted Pressure Filter, DF...M P, Flange Mounted up to 550 l/min, up to 260 bar DF...M P 330...1.X 160 240 280 500...1.X 660...1.X 660...2.X 990...2.X 1320...2.X 660...3.X 990...3.X 1320...3.X 1. TECHNICAL SPECIFICATIONS

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 45 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold

More information

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm Hydraulic Symbol A B Features Meets HF4 automotive standard Non-welded housing design reduces stress concentrations and prevents

More information

Reservoir oil filler/breather

Reservoir oil filler/breather Reservoir oil filler/breather RE 50070/10.05 Replaces: 01.03 1/10 Types ELF, BF and BL R 7802_2 Reservoir oil filler/breather with sieve type ELF 3... H_S_95 Reservoir breather type BF 7...K... Overview

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,

More information

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF up to 600 l/min, up to 315 bar 60 110 140 160 240 280 330 500 660 1.X 660 2.X 990 1320 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING

More information

Hydraulic gear pumps S F P

Hydraulic gear pumps S F P Hydraulic gear pumps FR TRUCK APPLICATINS S F P DEX Section Description Page FEATURES 2 SFP 30 BASE PUMP 9 SFP 30 KIT 10 SFP 30 IS STANDARD VERSIN 0 11 SFP 30 IS STANDARD VERSIN 5 12 SGLE GEAR PUMPS SFP

More information

MEDIUM PRESSURE FILTERS

MEDIUM PRESSURE FILTERS Medium Pressure Filters 61-2999 psi Low-cost aluminum construction inline filters, provide flexibility for use in both mobile and industrial applications. Durable and light weight, these filters are ideal

More information

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS 1 OIL FILTER DESCRIPTION Many years of in-field experience have shown the necessity of more and more efficient controls on the contamination level of hydraulic fluids and fuels. With this goal uppermost

More information

Pressure: Max working 160 bar (2300 psi) (acc. to NFPA T ) Burst 480 bar (6900 psi) (acc. to NFPA T )

Pressure: Max working 160 bar (2300 psi) (acc. to NFPA T ) Burst 480 bar (6900 psi) (acc. to NFPA T ) HYDRULIC FILTRTION F16-XD series In line medium pressure filters Technical Information Pressure: Max working 16 bar (3 psi) (acc. to NFP T 3.1..1) Burst 48 bar (69 psi) (acc. to NFP T 3.1..1) Housing Connection

More information

Low Pressure Filters

Low Pressure Filters MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol /80/85/160/180 MF 90/95/190/195 A A B B Features MF Filters are manufactured with an aluminum head. Choice of NPT, SAE straight

More information

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel Manifold Mounted, Rear Flanged Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 5 l/min Pressure range up to 35 bar Material: SG Iron/ADI, Steel . DESCRIPTION.. FILTER HOUSING

More information

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters Stainless steel high pressure fi lters FZP series Maximum pressure up to 0 bar 55 Stainless steel high pressure filters FILTER SIZING The correct filter sizing have to be based on the variable pressure

More information

Filtrec elements are tested also according to ISO 2942, ISO and ISO 3968

Filtrec elements are tested also according to ISO 2942, ISO and ISO 3968 HYDULIC FILTTION F-1 series Spin-on filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFP T 3.10.17) Burst 20 bar (290 psi) (acc. to NFP T 3.10.17) Connection Ports: 3/4 1 1/2

More information

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron NF filters are designed for inline mounting and as tank-top mounted return line filters. These filters can also be used on filling, flushing and off-line units. Inline Filters NF Flow rates up to 3,500

More information

Return Line Filter RF

Return Line Filter RF HYDAC return line filters type RF are designed to be mounted directly on tank tops. Inline mounting is also possible. Return Line Filter RF Flow rates up to 5, l/min Pressure range up to 25 bar Material:

More information

Technical specifications

Technical specifications Low noise bell housings LMS series Bell housings of this type, appropriately installed in hydraulic systems, are able to help bring about a significant reduction in the level of noise generated by the

More information

FPK02 In-Line Cartridge Filters

FPK02 In-Line Cartridge Filters HIGH PRESSURE FILTERS FPK2 Max Flow: gpm (9 lpm) FPK2 In-Line Cartridge Filters Working Pressures to: Rated Static Burst to: Flow Range to: 69 psi 42, kpa 42 bar 913 psi 63, kpa 63 bar gpm 9 lpm Features

More information

SPIN-ON FILTERS & ELEMENTS

SPIN-ON FILTERS & ELEMENTS ABSOLUTE RATED (BETA SPIN ) & NOMINAL RATED SPIN-ON FILTERS & ELEMENTS Single and Twin Element Models Pressures to 20 psi Flows to 120 gpm APPLICATION HYDAC Spin-On Filters are for filtration of hydraulic

More information

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi) HYDRAULIC FILTRATION F8-D1 series In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x:

More information

Variable displacement axial piston pumps,

Variable displacement axial piston pumps, ariable displacement axial piston pumps, for open circuit DISPLACEMENTS From To 2.75 in 3 /rev (45 cm 3 /rev) 5.12 in 3 /rev (84 cm 3 /rev) MAX SPEED 3000 min -1 PRESSURE Max. continuous Max. intermittent

More information

Medium Pressure Filters

Medium Pressure Filters Medium Pressure Filters Medium pressure filters can be used in applications up to 2 psi (1379 kpa). Donaldson offers both spin-on and in-line cartridge-style filters. Medium Pressure Filters MEDIUM PRESSURE

More information

MATERIALS FILTER PRESSURE VALUES

MATERIALS FILTER PRESSURE VALUES INTRODUCTION Thanks to many years of in-field experience regarding research, design and production of oil filters and oil separation for compressors applications, the high quality standard reached by FAI

More information

Pressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T )

Pressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T ) HYDRULIC FILTRTION In line high pressure filters Technical Information Pressure: Max working 420 bar (6000 psi) (acc. to NFP T 3.10.5.1) Burst 1260 bar (18300 psi) (acc. to NFP T 3.10.5.1) Housing Connection

More information

OIL FILLER AND AIR BREATHER FILLER CAPS

OIL FILLER AND AIR BREATHER FILLER CAPS OIL FILLER ND IR RETHER FILLER CPS The complete series of oil filter and makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. s perform

More information

Oil Solutions. RIF 300 Return Line Filters. Local solutions for individual customers worldwide FILTRATION TECHNOLOGY

Oil Solutions. RIF 300 Return Line Filters. Local solutions for individual customers worldwide FILTRATION TECHNOLOGY Oil Solutions FILTRATION TECHNOLOGY RIF 3 Return Line Filters Local solutions for individual customers worldwide www.oilsolutions.com.au sales@oilsolutions.com.au Distributor Walter Stauffenberg GmbH &

More information

FMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I.

FMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I. 30 FMM 050 SRIS FMM 050 Working pressure 0 bar Style S Style Style T Style D 3 3 Technical data Filter body (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel (chemical heat treatment)

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 4 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold block

More information

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM.

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM. MATERIALS Head: Aluminium alloy Bowl: Steel Bypass valve: Steel Seals: NBR Nitrile (FKM - on request fluoroelastomer) Indicator housing: Brass PRESSURE Max working: 5 MPa ( bar) Collapse, differential

More information

FBK-FRCA. Return Line Filters Low Pressure Filters In-Line up to 10 bar. Mix&Match to Get What You Need

FBK-FRCA. Return Line Filters Low Pressure Filters In-Line up to 10 bar. Mix&Match to Get What You Need Return Line Filters Low Pressure Filters In-Line up to 10 bar Mix&Match to Get What You Need Donaldson's Mix&Match system provides the great performance and functional advantages of custom-engineered filters

More information

Return line filter for direct tank mounting Type ABZFR

Return line filter for direct tank mounting Type ABZFR RE 5 8/. Replaces: 7.99 Return line filter for direct tank mounting Type ABZFR Maximum operating pressure 5 bar Maximum flow 5 l/min H69+69.tif Return line filter type ABZFR Table of contents Contents

More information

Return Line Filters. Section Index

Return Line Filters. Section Index Hydraulic Return Line Filters Section Index NEW UNIQUE DESIGN CONCEPT Return & Suction Filters In Tank Combo 120 Series.................... 64 Combo 200 Series.................... 74 ADDITIONS FIK-FIO..............................

More information

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition: Spin-on elements Type 80, 81 and 82 RE 51478 Edition: 2015-06 Sizes according to according to Bosch Rexroth standard: 30 to 130 Pressure differential resistance up to 5 bar [72.5 psi] Filter rating: 1

More information

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min Low & Medium Pressure fi lters LMP - series Maximum pressure up to 8 bar - Flow rate up to l/min 5 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

Variable displacement axial piston pumps

Variable displacement axial piston pumps Variable displacement axial piston pumps SVP series GENERAL INFORMATIONS Variable displacement axial piston pump swash plate design for open circuit-flow sharing control valve. The pump has been designed

More information

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min Low & Medium Pressure filters LDP & series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE

More information

Series RFL In-Line Filter

Series RFL In-Line Filter APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction

More information

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04 Inline Filter MFM Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS 400-15 / steel 1. TECHNICAL SPECIFICATIONS 1.1. FILTER HOUSING Construction The inline filter consists of a filter

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION F4-DMD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1..1): F4-DMD/8/11: 7 bar (11 psi) F4-DMD1/3/4: 4 bar (8 psi) Housing Burst

More information

MPF filters within this range are suitable for flow rates up to 750 l/min.

MPF filters within this range are suitable for flow rates up to 750 l/min. D e s c r i p t i o n MPF series filters are designed for return lines, and are installed semi-immersed in a reservoir. Continued Research & Development on both the filter bodies and the filter elements

More information

Pictorial Index Hydraulic Filters

Pictorial Index Hydraulic Filters Hydraulic Filters Reservoir Accessories Pictorial Index Hydraulic Filters RIF-10 INLINE SPIN-ON FILTERS 1.1/4 S PAGES 356-357 PAGES 360-361 RTI AND RFI TANK TOP FILTERS PAGES 366-367 S: 1.1/4 BSPP MAX.

More information

Low & High Pressure ProGuard Filters

Low & High Pressure ProGuard Filters 56 ±.2 (2.2 ±.5) ø13 +1.5 (5.12 +.6 ) INDICATOR PLUG 193 (7.6) 14 (5.51) 95 (3.74) LABEL 1 5/8-12UNF IN. OR G 1 1/4 PORT SAE-2 PORT 2 PL'S 196 (7.72) 58 (2.28) ø13.2 (5.13) L (4 Low & High Pressure ProGuard

More information

Return Line Filter RFM with 4-Hole Mounting

Return Line Filter RFM with 4-Hole Mounting Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 195 210 270 330 500 600 661 851 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Return Line Filter RFM with 4-Hole Mounting

Return Line Filter RFM with 4-Hole Mounting Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 210 270 330 500 600 661 851 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar 160 240 260 280 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international

More information

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure Inline filters up to 3500 l/min, up to 25 bar 160 240 280 330 500 750 950 1350 2650 on request 1310 2.x on request 2610 2.x 1340 2640 5240 7840 10440 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Medium Pressure Filters

Medium Pressure Filters Medium Pressure Filters Medium pressure filters can be used in applications up to psi (379 kpa). Donaldson offers both spin-on and in-line cartridge-style filters. Medium Pressure Filters Donaldson Duramax

More information

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01. Change-Over Inline Filter RFLD Cast Version Flow Rates up to 3 l/min* Pressure Range 25/4/64 bar With Ball Change-Over Valve * For higher flow rates, please refer to brochure RFLD Welded Version E 7.9.2/.4

More information

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX up to 2000 l/min, up to 420 bar DF/DFF...1.X/2.X 30 60 110 140 160 240 280 330 500 660 990 1320 1500 2000 3000 4000 DF...3.X DFFX...1.X/2.X

More information

12AT/50AT Series Spin-On Filters

12AT/50AT Series Spin-On Filters 1 Applications for Mobile Equipment Hydrostatic Drives Industrial Power Units Reservoir Breathers Often, economic conditions dictate what type of filter is used on a piece of equipment. When costs are

More information