LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

Size: px
Start display at page:

Download "LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min"

Transcription

1 Low & Medium Pressure fi lters LMP - series Maximum pressure up to 8 bar - Flow rate up to l/min 5 Low & Medium Pressure filters

2 FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for the return filter the pressure drop have to be in the range. -.6 bar. The pressure drop calculation is performed by adding together the value of the housing with the value of the filter element. The pressure drop in the housing is proportional to the fluid density (kg/dm ); all the graphs in the catalogue are referred to mineral oil with density of.86 kg/dm. The filter element pressure drop is proportional to its viscosity (mm /s), the corrective factor Y is related to an oil viscosity different than mm /s. Sizing data for single cartridge, head at top pc = housing pressure drop [bar] pe = element pressure drop [bar] Y = Multiplication factor Y (see correspondent table), depending on the filter element size, on the filter element lenght and on the filter media Q = flow rate (l/min) V reference viscosity = mm /s (cst) V = operating viscosity in mm /s (cst) pe = Y : x Q x (V/V) p Tot. = pc + pe Calculation examples with HLP Mineral oil Variation in viscosity Application data: Top tank return filter with in-line connections Pressure Pmax = bar Flow rate Q = l/min Viscosity V = 6 mm /s (cst) Oil viscosity =.86 kg/dm Required filtration efficiency = 5 μm with absolute filtration With bypass valve and / inlet connection From the working pressure and the flow rate we understand it should be possible using the following top tank return filter series: MPT, MPH and FRI. Let s proceed with MPT series. The size doesn t achieve the required flow rate, therefore we have to consider the size. The final version of size (,,, and ) will be then defined in function of the mounting characteristics. pc =. bar ( see graphic below, considering size with the max available lenght * to get the lowest pressure drop) pe = (. : ) x x (6/) =.7 bar p Tot. =. +.7 =. bar The selection is correct because the total pressure drop value is inside the admissible range for top tank return filters. It is of course possible trying to find a different solution, according to the mounting position or to other commercial need, repeating the previous steps while using a different series or lenght. MPT - Length * G / 6 8 housings p pressure drop. The curves are plotted using mineral oil with density of.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity mm /s Return filters element Type MF MF MFX MF MFX MF 8 MFX 8 MF 9 MFX 9 MF MFX MF 75 MFX 75 CU 5 CU CU CU 5 CU 6 CU 85 MR MR 5 MR 6 MR A Absolute filtration Nominal filtration H Series N Series A6 A A6 A5 P P5 M5 M6 M Introduction

3 Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity mm /s Suction filters element Type SF 5 Nominal filtration N Series P P5 65 Low & Medium pressure filters element Type CU A FILTER SIZING Absolute filtration Nominal filtration N-W Series N Series A6 A A6 A5 P P5 M Return / Suction filters element Type RSX 6 A 5.. Absolute filtration A6..87 A5.85. CU DN RSX CU CU CU MR Introduction

4 FILTER SIZING Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity mm /s High pressure filters element Type HP A Absolute filtration N - R Series A6 A A A Nominal filtration N Series M Stainless steel high pressure filters element Type HP A Absolute filtration N Series A6 A A A HP HP HP HP HP HP HP 5 HP element Type HP A Absolute filtration H - U Series A6 A A A HP HP element Type A Absolute filtration N Series A6 A A6 A5 Nominal filtration N Series M5 HP HF HP Introduction

5 Selection Software FILTER SIZING Step Select FILTERS Step Choose fi lter group (Return, Pressure, etc.) Step Choose fi lter type (MPF, MPT, etc.) in function of the max working pressure and the max fl ow rate Step Push PROCEED Step 5 Insert all application data to calculate the fi lter size following the sequence: - working pressure - working fl ow rate - working pressure drop - working temperature - fl uid material and fl uid type - fi ltration media - connection type Step 6 Push CALCULATE to have result; in case of any mistake, the system will advice which parameter is out of range to allow to modify/adjust the selection Step 7 Download PDF Datasheet Report.aspx pushing the button Drawing Introduction

6 Low & Medium Pressure filters

7 Low & Medium Pressure fi lters LMP - series Maximum pressure up to 8 bar - Flow rate up to l/min 5 Low & Medium Pressure filters

8 LMP - GENERAL INFORMATION Technical data Low & Medium Pressure filters Maximum pressure up to 8 bar - Flow rate up to l/min housing materials - Head: Aluminium - Housing: Cataphoresis - Painted Steel - Bypass valve: Brass - Aluminium Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: 8 MPa (8 bar) - Test pressure: MPa ( bar) - Burst pressure: LMP : 9 MPa (9 bar) LMP /: 8 MPa (8 bar) - Pulse pressure fatigue test: cycles with pressure from to 8 MPa (8 bar) Temperature From -5 C to + C Note LMP filters are provided for vertical mounting Bypass valve - Opening pressure.5 bar ±% - Other opening pressures on request. p element type - Microfibre filter elements - series N - W: bar - Wire mesh filter elements - series N: bar - Fluid flow through the filter element from OUT to IN. Weights [kg] and volumes [dm ] LMP LMP LMP Length Weights [kg] Length Volumes [dm ] Low & Medium Pressure filters 6

9 GENERAL INFORMATION LMP - Multiport LMP LMP In-Line fi lter Port IN-OUT on the same side LMP Double IN port LMP Lateral OUT port high fl ow LMP 6 Double OUT port Type LMP Bypass valve for heat exchanger high fl ow C B A LMP 8 Bypass lateral. Always cleaning fl uid in OUT port Type C B A LMP 9 Safety valve 6 bar for heat exchanger 7 Low & Medium Pressure filters

10 LMP LMP.9.9 / LMP / /.9 /.6.6 LMP -.6 LMP LMP 8 - Setting.5 bar The curves are plotted using mineral oil 8 Pressure drop / / with density of.86 kg/dm in compliance with ISO p varies proportionally with density LMP LMP / Flow rate OUT / l/min OUT /.6.6 LMP LMP 8 - Setting.5 bar.9 8 /...6 Δp bar Flow Flow rate rate l/min l/min LMP 6.9 IN LMP - - Setting.5 bar.99 LMP / -.6 A>C A>B Flow Flow rate rate l/min l/min Δp bar A>C A>B GENERAL INFORMATION.6 housings Valves Valves p pressure drop LMP Bypass valve pressure drop Bypass valve pressure drop OUT OUT Flow LMP rate / l/min Setting.5 bar LMP - housing wit.6 LMP - - Setting.5 bar LMP LMP LMP - Setting 6 bar.9 8 / / IN / Flow Flow rate rate l/min l/min LMP.9. Δp Δp bar bar 8 Flow rate 8 8 Flow Flow rate LMP - Setting 6 bar 8 LMP - housing wi 8 Δp Δp bar bar Flow Flow rate rat Valves Bypass valve LMP.9pressure drop / LMP Setting.5 bar LMP.9 A>C LMP - housing with bar check valve A>B.6 8. A>C A>B es LMP LMP - - Setting housing 6 bar with bar check valve 8 A>C 8 6 A>B 8 LMP - housing with bar check valve A>C A>B Flow Flow rate rate l/min LMP - housing with bar check valve A>C A>B 8 6 Low & Medium Pressure filters 8

11 GENERAL INFORMATION The curves are plotted using mineral oil with density of.86 kg/dm in compliance with ISO 968. p varies proportionally with density. LMP - Pressure drop LMP Setting.5 bar 8 LMP 8 - Setting.5 bar Bypass valve pressure drop LMP - - Setting.5 bar Low & Medium Pressure filters

12 LMP Designation & Ordering code LMP - LMP - LMP6 Series and size LMP LMP LMP6 Length Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMP B A D A N P Connections A G/ B G C / NPT D NPT E SAE - /6 - UN F SAE 6-5/6 - UN Aux (only LMP - 6) G/ G/ / NPT / NPT SAE - /6 - UN SAE - /6 - UN Connection for differential indicator Without With standard connection With connection on the opposite side 6 With two connections on both sides Filtration rating (filter media) A Inorganic microfiber µm M5 Wire mesh 5 µm A6 Inorganic microfiber 6 µm M6 Wire mesh 6 µm A Inorganic microfiber µm M9 Wire mesh 9 µm A6 Inorganic microfiber 6 µm P Resin impregnated paper µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N bar Execution P MP Filtri standard Pxx Customized Element series and size CU FILTER ELEMENT Configuration example: CU A A N P Element length Filtration rating (filter media) A Inorganic microfiber µm M5 Wire mesh 5 µm A6 Inorganic microfiber 6 µm M6 Wire mesh 6 µm A Inorganic microfiber µm M9 Wire mesh 9 µm A6 Inorganic microfiber 6 µm P Resin impregnated paper µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N bar Additional features page T Plug ACCESSORIES Execution P MP Filtri standard Pxx Customized Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9- DVA Visual differential indicator DLA Electrical / visual differential indicator - DVM Visual differential indicator DLE Electrical / visual differential indicator Low & Medium Pressure filters

13 LMP - LMP - LMP6 LMP Dimensions LMP - LMP LMP6 length H [mm] Recommended clearance space for maintenance Low & Medium Pressure filters

14 LMP Designation & Ordering code LMP8 - LMP9 Series and size LMP8 LMP9 Length Bypass valve B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMP8 B A D A N P Connections A G/ B G C / NPT D NPT E SAE - /6 - UN F SAE 6-5/6 - UN Aux OUT G/ G/ / NPT / NPT SAE - /6 - UN SAE - /6 - UN Connection for differential indicator Without With standard connection Filtration rating (filter media) A Inorganic microfiber µm M5 Wire mesh 5 µm A6 Inorganic microfiber 6 µm M6 Wire mesh 6 µm A Inorganic microfiber µm M9 Wire mesh 9 µm A6 Inorganic microfiber 6 µm P Resin impregnated paper µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N bar Execution P MP Filtri standard Pxx Customized Element series and size CU FILTER ELEMENT Configuration example: CU A A N P Element length Filtration rating (filter media) A Inorganic microfiber µm M5 Wire mesh 5 µm A6 Inorganic microfiber 6 µm M6 Wire mesh 6 µm A Inorganic microfiber µm M9 Wire mesh 9 µm A6 Inorganic microfiber 6 µm P Resin impregnated paper µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N bar Execution P MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9- DVA Visual differential indicator DLA Electrical / visual differential indicator - DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

15 LMP8 - LMP9 LMP Dimensions LMP8 - LMP9 length H [mm] Recommended clearance space for maintenance Low & Medium Pressure filters

16 LMP Designation & Ordering code LMP - LMP Series and size LMP LMP Length Bypass valve S Without bypass B.5 bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC COMPLETE FILTER Configuration example: Filtration rating Axx Mxx Pxx LMP B A D A N P Connections A G/ B G C / NPT D NPT E SAE - /6 - UN F SAE 6-5/6 - UN LMP LMP Connection for differential indicator Without With standard connection Filtration rating (filter media) A Inorganic microfiber µm M5 Wire mesh 5 µm A6 Inorganic microfiber 6 µm M6 Wire mesh 6 µm A Inorganic microfiber µm M9 Wire mesh 9 µm A6 Inorganic microfiber 6 µm P Resin impregnated paper µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N bar Execution P MP Filtri standard Pxx Customized Element series and size CU FILTER ELEMENT Configuration example: CU A A N P Element length Filtration rating (filter media) A Inorganic microfiber µm M5 Wire mesh 5 µm A6 Inorganic microfiber 6 µm M6 Wire mesh 6 µm A Inorganic microfiber µm M9 Wire mesh 9 µm A6 Inorganic microfiber 6 µm P Resin impregnated paper µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N bar Execution P MP Filtri standard Pxx Customized ACCESSORIES Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9- DVA Visual differential indicator DLA Electrical / visual differential indicator - DVM Visual differential indicator DLE Electrical / visual differential indicator Additional features page T Plug Low & Medium Pressure filters

17 LMP - LMP length LMP LMP Dimensions H [mm] Connections A - B C - D - E - F R M /8 UNC Recommended clearance space Recommended for maintenance clearance space for maintenance length LMP H [mm] Connections B D - F R M /8 UNC Recommended clearance space for maintenance 5 Low & Medium Pressure filters

18 LMP LMP Designation & Ordering code Series and size LMP Length COMPLETE FILTER Configuration example: LMP R A F A N P Valves C D G H M N Q R Bypass OUT to cooler Check valve without front bar bar side bar bar.5 bar front bar bar side bar bar Seals and treatments A NBR V FPM W NBR compatible with fluids HFA-HFB-HFC Filtration rating Axx Mxx Pxx Connections B F G SAE 6-5/6 - UN Connection for differential indicator Without With standard connection Filtration rating (filter media) A Inorganic microfiber µm M5 Wire mesh 5 µm A6 Inorganic microfiber 6 µm M6 Wire mesh 6 µm A Inorganic microfiber µm M9 Wire mesh 9 µm A6 Inorganic microfiber 6 µm P Resin impregnated paper µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Element p N bar Execution P MP Filtri standard Pxx Customized Element series and size CU FILTER ELEMENT Configuration example: CU A A N P Element length Filtration rating (filter media) A Inorganic microfiber µm M5 Wire mesh 5 µm A6 Inorganic microfiber 6 µm M6 Wire mesh 6 µm A Inorganic microfiber µm M9 Wire mesh 9 µm A6 Inorganic microfiber 6 µm P Resin impregnated paper µm A5 Inorganic microfiber 5 µm P5 Resin impregnated paper 5 µm Seals A NBR V FPM W NBR Filtration rating Axx Mxx Pxx compatible with fluids HFA-HFB-HFC Element p N bar Additional features page T Plug ACCESSORIES Execution P MP Filtri standard Pxx Customized Differential indicators page page DEA Electrical differential indicator 9 DTA Electronic differential indicator DEM Electrical differential indicator 9- DVA Visual differential indicator DLA Electrical / visual differential indicator - DVM Visual differential indicator DLE Electrical / visual differential indicator Low & Medium Pressure filters 6

19 LMP length LMP LMP Dimensions H [mm] Connections B F R M /8 UNC Recommended clearance space for maintenance 7 Low & Medium Pressure filters

20 LMP - Order number for spare parts SPARE PARTS LMP LMP LMP - c d d c d c a a a b b b Item: series LMP LMP LMP - Q.ty: pc. Q.ty: pc. Q.ty: pc. (a d) Seal Kit code number Indicator connection plug element NBR FPM NBR FPM See order table TH TV Low & Medium Pressure filters 8

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min Low & Medium Pressure filters & series Maximum pressure up to 60 bar Flow rate up to 0 l/min DIN 550 09 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters High Pressure fi lters FHF5 series Maximum pressure up to 50 bar Flow rate up to 500 l/min housing according to SAE J066 for HF filter s 95 High Pressure fi lters FILTER SIZING The correct filter sizing

More information

Return / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters

Return / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters Return / Suction fi lters Inline LMP series Maximum pressure up to 8 bar Flow rate up to l/min 9 Return / Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure

More information

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters igh Pressure fi lters FP series Maximum pressure up to bar Flow rate up to 7 l/min igh Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending

More information

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters Stainless steel high pressure fi lters FZP series Maximum pressure up to 0 bar 55 Stainless steel high pressure filters FILTER SIZING The correct filter sizing have to be based on the variable pressure

More information

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min Low & Medium Pressure filters LDP & series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE

More information

LMP series

LMP series Low & Medium Pressure fi lters LMP 95-95-95 series Maximum working pressure up to.5 MPa (5 bar) - Flow rate up to 000 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE

More information

Return / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters

Return / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters Return / Suction fi lters mounted MRSX series Maximum pressure up to bar Flow rate up to l/min 9 Return / Suction fi lters FILTER SIZG The correct filter sizing have to be based on the variable pressure

More information

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters Return fi lters series Maximum pressure up to bar - Flow rate up to 15 l/min 193 Return fi lters GENERAL INFORMATION Technical data Return filter Maximum pressure up to bar - Flow rate up to 15 l/min Filter

More information

NEW. High Pressure filters. FMM 150 series. Maximum pressure up to 420 bar - Flow rate up to 250 l/min

NEW. High Pressure filters. FMM 150 series. Maximum pressure up to 420 bar - Flow rate up to 250 l/min NEW High Pressure filters FMM 50 series Maximum pressure up to 0 bar - Flow rate up to 50 l/min PASSION TO PERFORM FILTER SIZING THE CORRECT FILTER SIZING HAVE TO BE BASED ON THE TOTAL PRESSURE DROP DEPENDING

More information

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n RF2 96 Maximum pressure 20 bar F l o w r a t e s t o 4 5 5 l / m i n Filter housing (Materials) Filter body: luminium over: Nylon Valve: Nylon - Steel nti-emptying valve: Steel Pressure Working pressure:

More information

Flow rates to 500 l/min

Flow rates to 500 l/min FF 5 Filter housing in according to SE J066 for F filter elements Maximum pressure 50 bar Flow rates to 500 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing:

More information

Flow rates to 3000 l/min

Flow rates to 3000 l/min MPH Maximum pressure bar Flow rates to l/min echnical data housing (Materials) Head: luminium: MPH nodised luminium: MPH 68 Painted luminium: MPH 66 Cover: Nylon: MPH luminium: MPH nodised luminium: MPH

More information

FMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I.

FMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I. 30 FMM 050 SRIS FMM 050 Working pressure 0 bar Style S Style Style T Style D 3 3 Technical data Filter body (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel (chemical heat treatment)

More information

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:

More information

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data Filter housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:

More information

PRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

PRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C COMPONENTS MATERIALS Head: Aluminium alloy Spinon cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile (FKM on request fluoroelastomer) Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO

More information

Working pressure. 350 bar. Style B Series FHD 051. Series FHD 325/332 D.I. D.I. D.I. A A

Working pressure. 350 bar. Style B Series FHD 051. Series FHD 325/332 D.I. D.I. D.I. A A 98 FD SRIS FD Working pressure 350 bar Style S Style Series FD 05 Style Series FD 35/33 D.I. D.I. D.I. 99 Technical data body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical

More information

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass COMPONENTS RC MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2002) Max working:

More information

MPT SERIES RETURN FILTER

MPT SERIES RETURN FILTER MPT SRIS The series of filters MPT has specifically been designed for use on mobile power packs for industrial, mobil and lift truk applications. The MPT filter range is suitable for flow rates up to 50

More information

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass COMPONENTS RB MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2) Max working: 0 kpa

More information

FHA 051 Working pressure 6000 psi

FHA 051 Working pressure 6000 psi 6 SRIS Working pressure 6000 psi Style S Style Style T Style D Style V Style Z D.I. 7 8 Technical data Filter body (Materials) Head: Steel (chemical heat treatment) Housing: Steel (chemical heat treatment)

More information

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHB series filters are designed for pressure line applications where manifold mounting is a specific requirement. The manifold type filters are designed to integrate onto manifold

More information

Hydraulic Filtration Products PANTONE.pdf 1 09/08/17 18:34 SPIN-ON FILTERS C M Y CM MY CY CMY K

Hydraulic Filtration Products PANTONE.pdf 1 09/08/17 18:34 SPIN-ON FILTERS C M Y CM MY CY CMY K SPIN-ON FILTERS A WORLDWIDE LEADER IN THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 96, when Bruno Pasotto decided to attempt to cater for the requests of a market still to

More information

SPIN-ON FILTER - LOW PRESSURE LINE

SPIN-ON FILTER - LOW PRESSURE LINE SERIES MSH SPIN-ON FILTER - LOW PRESSURE LINE Maximum working pressure 5 psi Flow rate to 8 GPM D e s c r i p t i o n MSH working pressure of 5 psi, with a peak pressure This filter MSH series utilises

More information

LOW & MEDIUM PRESSURE FILTERS

LOW & MEDIUM PRESSURE FILTERS LOW & MEDIUM PRESSURE FILTERS A WORLDWIDE LEADER IN THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 96, when Bruno Pasotto decided to attempt to cater for the requests of a market

More information

Return Line Filter RFM with 4-Hole Mounting

Return Line Filter RFM with 4-Hole Mounting Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 195 210 270 330 500 600 661 851 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

STAINLESS STEEL HIGH PRESSURE FILTERS

STAINLESS STEEL HIGH PRESSURE FILTERS STAINLESS STEEL HIGH PRESSURE FILTERS A WORLDWIDE LEADER IN THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 96, when Bruno Pasotto decided to attempt to cater for the requests

More information

D e s c r i p t i o n

D e s c r i p t i o n e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed (MPH) or totally immersed into

More information

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 12 bar Flow rates to 3 l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for

More information

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min INLIN FILTR Maximum working pressure 0 bar Flow rate to 00 l/min R.F. Filter Symbol without bypass Filter Symbol with Reverse Flow R.F. Filter Symbol with bypass Filter Symbol with bypass & Reverse Flow

More information

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a New Headquarters : MP FILTRI S.p.. Italy Via 1 Maggio, n. 3 Pessano con Bornago (Milano) Italy Tel. +39./973.1 Fax +39./9741497-974188 email: sales@mpfiltri.com http://www.mpfiltri.com GRT BRITIN MP FILTRI

More information

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S.. Suction Filter /M/F and Suction Filter Elements S/S.. up to 500 l/min Filters: 60 110 160 240 330 M 330 F 400 F 500 Elements: S SH. SU. SG. 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The

More information

D e s c r i p t i o n

D e s c r i p t i o n D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

RETURN / SUCTION FILTERS

RETURN / SUCTION FILTERS RETURN / SUCTION FILTERS A WORLDWIDE LEADER THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 9, when Bruno Pasotto decided to attempt to cater for the requests of a market still

More information

SERIES. Maximum pressure 110 bar

SERIES. Maximum pressure 110 bar SERIES Maximum pressure 0 bar F l o w r a t e s t o 9 5 l / m i n Technical data FMP 09 Compatibility Filter housing (Materials) Head: nodized aluminium Housing: nodized aluminium Bypass valve: Steel Pressure

More information

Return Line Filter RFM with 4-Hole Mounting

Return Line Filter RFM with 4-Hole Mounting Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 210 270 330 500 600 661 851 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Return Line Filter HF4R up to 450 l/min, up to 10 bar Return Line Filter HF4R up to 450 l/min, up to 10 bar 9" 18" 27" 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international regulations.

More information

MPF filters within this range are suitable for flow rates up to 750 l/min.

MPF filters within this range are suitable for flow rates up to 750 l/min. D e s c r i p t i o n MPF series filters are designed for return lines, and are installed semi-immersed in a reservoir. Continued Research & Development on both the filter bodies and the filter elements

More information

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04 Inline Filter MFM Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS 400-15 / steel 1. TECHNICAL SPECIFICATIONS 1.1. FILTER HOUSING Construction The inline filter consists of a filter

More information

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron NF filters are designed for inline mounting and as tank-top mounted return line filters. These filters can also be used on filling, flushing and off-line units. Inline Filters NF Flow rates up to 3,500

More information

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHP series filters are designed for high pressure line applications and are suitable for in-line installation. Continued research and development on both the filter bodies and the

More information

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S..

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S.. Suction Filter /M/F and Suction Filter Elements S and S.. up to 500 l/min Filters: 60 100 160 240 330 M 330 F 400 F 500 Elements: S SH. SU. SG. 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 2500 l/min, up to 315 bar 30 60 110 140 160 240 280 330 500 660 1.x 660 2.x 990 2.x 1320 2.x 1320 3.x 2640 3.x 3960 3.x 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING

More information

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF up to 600 l/min, up to 315 bar 60 110 140 160 240 280 330 500 660 1.X 660 2.X 990 1320 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING

More information

Change-Over Inline Filter RFLD Welded Version

Change-Over Inline Filter RFLD Welded Version Change-Over Inline Filter RFLD Welded Version up to 15000 l/min, up to 16 bar RFLD 1300 CAS to RFLD 15000 CBW 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed

More information

Pressure Filter DF...K P, DF...M P, Flange Mounted

Pressure Filter DF...K P, DF...M P, Flange Mounted Pressure Filter, DF...M P, Flange Mounted up to 550 l/min, up to 260 bar DF...M P 330...1.X 160 240 280 500...1.X 660...1.X 660...2.X 990...2.X 1320...2.X 660...3.X 990...3.X 1320...3.X 1. TECHNICAL SPECIFICATIONS

More information

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar RFL inline filters are designed for inline mounting in hydraulic and lubrication systems. Inline Filter RFL Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar * For larger flow rates,

More information

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM.

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM. MATERIALS Head: Aluminium alloy Bowl: Steel Bypass valve: Steel Seals: NBR Nitrile (FKM - on request fluoroelastomer) Indicator housing: Brass PRESSURE Max working: 5 MPa ( bar) Collapse, differential

More information

Return Line Filter RF

Return Line Filter RF Return Line Filter up to 15000 l/min, up to 25 bar 30 60 110 160 240 330 450 580 660 950 1300 2500 4000 5200 6500-7800 15000 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings

More information

Hydraulic Filtration. Product Range. Low & Medium Pressure Filters. Return Filters MPFX MPTX MFBX. China United Kingdom India Canada

Hydraulic Filtration. Product Range. Low & Medium Pressure Filters. Return Filters MPFX MPTX MFBX. China United Kingdom India Canada M Y (Not LMP900-901/902-903/950-951/952-953-954) Positioned on the return line to the tank, return filters perform the task of filtering fluid and preventing particles entering the system - externally

More information

HYDRAULIC FILTRATION PRODUCTS

HYDRAULIC FILTRATION PRODUCTS HYDRAULIC FILTRATION PRODUCTS HIGH PRESSURE FILTERS PASSION TO PERFORM A WORLDWIDE LEADER THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 96, when Bruno Pasotto decided to attempt

More information

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX up to 2000 l/min, up to 420 bar DF/DFF...1.X/2.X 30 60 110 140 160 240 280 330 500 660 990 1320 1500 2000 3000 4000 DF...3.X DFFX...1.X/2.X

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

Change-Over Inline Filter RFLD Weld Version

Change-Over Inline Filter RFLD Weld Version Change-Over Inline Filter RFLD Weld Version up to 15000 l/min, up to 16 bar RFLD 1300 CAS to RFLD 15000 CBW 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The fi lter housings are designed

More information

Return Line Filter RF

Return Line Filter RF HYDAC return line filters type RF are designed to be mounted directly on tank tops. Inline mounting is also possible. Return Line Filter RF Flow rates up to 5, l/min Pressure range up to 25 bar Material:

More information

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min Suction Filters ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min Description Application To be installed in the suction line of the pumps of hydraulic systems resp. upstream

More information

Change-Over Inline Filter AFLD to API 614

Change-Over Inline Filter AFLD to API 614 Change-Over Inline Filter to API 614 up to 17 l/min, up to 4 bar 112/ 113 122/ 123 232/ 233 242/243 332/333 52/53 542/543 882/883 142/143 272/273 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar 160 240 260 280 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international

More information

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Suction Filters LS 025 LS 035 In-line mounting Connection up to G¾ / -2 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Description Application To be installed in the suction line of the pumps of hydraulic

More information

Return line and Suction Boost Filter RKM

Return line and Suction Boost Filter RKM Return line and Suction Boost Filter up to 850 l/min, up to 10 bar 80 100 120 151 201 251 201/-TH 300 350 400 800 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed

More information

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure Inline filters up to 3500 l/min, up to 25 bar 160 240 280 330 500 750 950 1350 2650 on request 1310 2.x on request 2610 2.x 1340 2640 5240 7840 10440 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181 Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to

More information

Block mounting filter, lateral flange-mounting possible

Block mounting filter, lateral flange-mounting possible Block mounting filter, lateral flange-mounting possible RE 0/.0 Replaces: 0.09 / Types 0/0 FEN 000 to 000; 0/0 FE 000, 00, 008 Nominal sizes according to DIN 0: 000 to 000 Nominal sizes according to BRFS:

More information

SRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction

SRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar Technical Data Filter Elements Main Operating pressure up to 1000 kpa (10 bar). Static pressure testing up to 1500 kpa (15 bar). Back pressure

More information

Inline filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550 Inline filter with filter element according to DIN 24550 RE 51421/07.11 Replaces: 12.10 1/16 Type 245LEN0040 to 400; 245LE0130, 0150 Size according to DIN 24550: 0040 to 0400 Additional sizes: 0130, 0150

More information

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01. Change-Over Inline Filter RFLD Cast Version Flow Rates up to 3 l/min* Pressure Range 25/4/64 bar With Ball Change-Over Valve * For higher flow rates, please refer to brochure RFLD Welded Version E 7.9.2/.4

More information

THE IMPORTANCE OF AN EFFICIENT FILTRATION

THE IMPORTANCE OF AN EFFICIENT FILTRATION In line high pressure filters HF 745 / HF 748 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the

More information

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

Filtering elements differential collapsing pressure tested in compliance with ISO 2941: DESCRIPTION Many years of in-field experience have shown the necessity of more and more efficient controls on the contamination level of hydraulic fluids and fuels. With this goal uppermost in its mind,

More information

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:

More information

Inline filter with filter element according to Bosch Rexroth standard. Type 16 FE Features. Contents

Inline filter with filter element according to Bosch Rexroth standard. Type 16 FE Features. Contents Inline filter with filter element according to Bosch Rexroth standard Type 16 FE 2500... 7500 RE 51403 Edition: 2014-11 Replaces: 01.09 Sizes according to according to Bosch Rexroth standard: 2500... 7500

More information

Inline filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550 Inline filter with filter element according to DIN 24550 RE 51422/07.11 Replaces: 12.10 1/18 Type 350LEN0040 to 1000; 350LE0130, 0150 Size according to DIN 24550: 0040 to 1000 Additional sizes: 0130, 0150

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Features MF Filters are manufactured with an aluminum head. MF, MFD, MFDS Series Spin-On Filters Choice of NPT, SAE straight thread O-ring boss, BSPP, and SAE 4-bolt flange porting to allow easy installation

More information

Line filter with filter element according to DIN 24550

Line filter with filter element according to DIN 24550 Line filter with filter element according to DIN 2455 RE 51423/9.12 Replaces: 7.1 1/2 Type 445LEN4 to 1 Size according to DIN 2455: 4 to 1 Nominal pressure: 45 bar [6527 psi] Connection up to G 1 1/2;

More information

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel Manifold Mounted, Rear Flanged Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 5 l/min Pressure range up to 35 bar Material: SG Iron/ADI, Steel . DESCRIPTION.. FILTER HOUSING

More information

Axial piston variable pump (A)A4VSO

Axial piston variable pump (A)A4VSO Axial piston variable pump (A)A4VSO RA 92050-A/06.09 1/64 Replaces: 09.97 Data sheet Series 10, 11 and 30 Size 40...1000 Nominal pressure 5100 psi (350 bar) Peak pressure 5800 psi (400 bar) Open circuit

More information

Low Pressure Filters

Low Pressure Filters MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol /80/85/160/180 MF 90/95/190/195 A A B B Features MF Filters are manufactured with an aluminum head. Choice of NPT, SAE straight

More information

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm SERIES SF2-250 SUCTION FILTER Flow rate to 45 gpm D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows

More information

Inline filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550 Inline filter with filter element according to DIN 24550 RE 51448/06.11 Replaces: RE 51400 1/18 Type 110LEN0040 to 0400; 110LE0130, 0150 Size according to DIN 24550: 0040 to 0400 Additional sizes: 0130,

More information

D 162 D 232 D 332 In-line mounting Operating pressure up to 63 bar Nominal flow rate up to 350 l/min

D 162 D 232 D 332 In-line mounting Operating pressure up to 63 bar Nominal flow rate up to 350 l/min Pressure Filters D 1 D 3 D 33 In-line mounting Operating pressure up to 3 bar Nominal flow rate up to 3 l/min Description Application In the pressure circuits of hydraulic and lubrication systems. Performance

More information

Replacement cartridge filter

Replacement cartridge filter Replacement cartridge filter RE 426/0. /2 Type 7 SL 0 to 260; 7 SLS 90 to 260; SL 0 to 80 D Size 7 SL: 0 to 260 7 SLS: 90 to 260 SL: 0 to 80 D Nominal pressure 7 and/or bar Port up to G /4, SAE /2 (000

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request) HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to

More information

Block mounting filter, for vertical flange-mounting

Block mounting filter, for vertical flange-mounting Block mounting filter, for vertical flange-mounting RE 51417/12.1 Replaces: 7.1 1/18 Type 45PBFN4 to 1; 45PBF13, 15 Size according to DIN 2455: 4 to 1 Additional sizes: 13, 15 Nominal pressure 45 bar [653

More information

Filter elements for installation in Pall filter housings. Type 16. filter elements. Contents. Features. RE Edition:

Filter elements for installation in Pall filter housings. Type 16. filter elements. Contents. Features. RE Edition: Filter elements for installation in Pall filter housings Type 16. filter elements RE 51464 Edition: 2014-04 Frame sizes: 6200 to 9801 Collapse pressure rating: 10 to 210 bar [145 to 3045 psi] Temperature

More information

Inline filter with filter element according to DIN Type 350LEN0040 to 1000; 350LE0130, 0150

Inline filter with filter element according to DIN Type 350LEN0040 to 1000; 350LE0130, 0150 Inline filter with filter element according to DIN 24550 Type 350LEN0040 to 1000; 350LE0130, 0150 RE 51422 Edition: 2015-03 Replaces: 07.11 Size as per DIN 24550: 0040 to 1000 Other sizes: 0130, 0150 Nominal

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:

More information

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm High Pressure Filters Worldline 4 HD 79 HD 99 In-line mounting Operating pressure up to bar / 97 psi Nominal flow rate up to. l/min / 4. gpm Description Application In the high pressure circuits of hydraulic

More information

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW FILTERS HYDRAULIC DIVISION - Suction filters SD TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW SPARE PARTS ORDERING INFORMATION DINSIONS OF

More information

Line filter. Features. RE 51400/01.09 Replaces: Types 40/100 LEN 0040 to 0400; 40/100 LE 0003, 0015, 0018

Line filter. Features. RE 51400/01.09 Replaces: Types 40/100 LEN 0040 to 0400; 40/100 LE 0003, 0015, 0018 Line filter RE /.9 Replaces: 8.8 / Types / LEN to ; / LE,, 8 Nominal sizes according to DIN : to Nominal sizes according to BRFS:,, 8 Nominal pressures, bar Connections up to G / Operating temperature

More information

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min Suction Filters ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min Description Application To be installed in the suction line of the pumps of hydraulic systems resp.

More information

Fluid Cooling Industrial COLW Series

Fluid Cooling Industrial COLW Series Fluid Cooling Industrial COLW Series 0916 COPPER & STEEL CONSTRUCTION Performance Notes Ideal for independent cooling and filtering of system oils Utilizes a high efficient EK series shell & tube (finned

More information

Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld

Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld 1. TECHNiCAL SPECIFICATIONS 1.1 Construction As the core of the, it is the element which performs the actual filtration and/or dewatering function in the housing. They consist of several pleated filtration

More information

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS 1 OIL FILTER DESCRIPTION Many years of in-field experience have shown the necessity of more and more efficient controls on the contamination level of hydraulic fluids and fuels. With this goal uppermost

More information

Type 10TDN0040 to 1000; 10TD2000 and 2500

Type 10TDN0040 to 1000; 10TD2000 and 2500 Duplex tank mounted return line filter, with filter element according to DIN 24550 Type 10TDN0040 to 1000; 10TD2000 and 2500 RE 51454 Edition: 2014-06 Replaces: 04.14 Size according to DIN 24550: 0040

More information

Tank top return-line filter Pi 5000

Tank top return-line filter Pi 5000 MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Tank top return-line filter Pi 5000 Nominal size 160 up to 1000 according to DIN 24550 1. Features

More information

Block mounting filter, for lateral flange-mounting

Block mounting filter, for lateral flange-mounting Block mounting filter, for lateral flange-mounting RE 51418/12.1 Replaces: 1.1 1/18 Type 245PSFN4 to 4; 245PSF13, 15 Size according to DIN 2455: 4 to 4 Additional sizes: 13, 15 Nominal pressure 25 bar

More information

SPIN-ON FILTERS & ELEMENTS

SPIN-ON FILTERS & ELEMENTS ABSOLUTE RATED (BETA SPIN ) & NOMINAL RATED SPIN-ON FILTERS & ELEMENTS Single and Twin Element Models Pressures to 20 psi Flows to 120 gpm APPLICATION HYDAC Spin-On Filters are for filtration of hydraulic

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION F4-DMD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1..1): F4-DMD/8/11: 7 bar (11 psi) F4-DMD1/3/4: 4 bar (8 psi) Housing Burst

More information

SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm

SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm SERIES SF2-5 SUTION FILTER Flow rates to 225 gpm D e s c r i p t i o n 5 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 225 gpm and filtration from

More information