SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm

Size: px
Start display at page:

Download "SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm"

Transcription

1 SERIES SF2-5 SUTION FILTER Flow rates to 225 gpm

2 D e s c r i p t i o n 5 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 225 gpm and filtration from 25 to 25 micron. The design of the SF2 ensures an excellent performance in terms of low pressure drop and high dirt holding capacity. The SF2 filters are without bypass and include a magnetic prefilter. The filtration flow from «inside to outside» of the filter element ensures that the contaminant is collected inside the element itself, avoiding contact with tank oil during element change. A major feature of these filters is that the filter element (situated under the oil level) can be changed without empting the reservoir; the valve is controlled by the handwheel on the filter cover. To avoid accidental start up when the valve is closed, an antistart safety switch is available as an option. logging indicators are available in electrical or visual stiles. These filters are particularly suitable for industrial application, die-casting and plastic injection machines. ELETRIAL SAFETY SWITH INDIATOR FILTER PORT ELETRIAL INDIATOR È OUTLET FILTER ELEMENT VISUAL INDIATOR UNI EN ISO 91 N 37/98 OIL SHUT OFF VALVE È INLET MAGNET OLUMN SF2 5 15/2./USA 2

3 MP Filtri - Filtration Technology Filter element: Materials End caps: Nylon Support tube: Steel expanded metal Support frames: Expanded metal Element material Nominal filtration MSeries Square wire mesh (filtration degree is defined in microns by the maximum diameter of a sphere corresponding to the mesh size). Filtering area Filter elements Type SF2 SF SF SF SF SF SF Values in IN 2 Filter body: Materials Working temperature Types of indicator Visual indicator Head Pressure aluminium die casting Steel (only for SF ) over Anodized aluminium 1 Óptional Flange Anodized aluminium Description: SF2 5 series filters are available with visual and electrical indicators. V Series (radial connection) V Series (axial connection) Seals A Series: Nitrile (una-n) V Series: Viton Indicator rass From -13 to +23 F For temperature outside this range, please consult our Sales and Network Organization vacuumeter: scale 3 in Hg vacuumeter: scale 3 in Hg Electrical indicator Electrical safety Switch N.. N.O. E1 Series: vacuumeter with change-over contacts at the setting pressure of 3 psi+1%. alibration range from 2.5 to 12.5 psi. The scheme refers to the oil shut off valve In a closed position Operational information: Max voltage: 22 Vac 5 6 Hz Max current:.5 A resistive,.2 A inductive. Protection degree IP65 Protection degree: IP67 Max voltage: 25Vca 5-6Hz Max current: 3A resistive 3A inductive 3

4 MP Filtri - Specification ompatibility with fluids Filter head and bowls compatible for use with: mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 6743/4) water-based emulsions (types HFAE-HFAS as per ISO 6743/4) synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO 6743/4) water-glycol (types HF as per ISO 6743/4) Ask for anodised version Filter elements As per ISO 2943; suitable for mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 6743/4) synthetic fluids (A and M series only) (types HS-HFDR-HFDS-HFDU as per ISO 6743/4) For water-based emulsions (type HFAE-HFAS as per ISO 6743/4) and fluids other than those mentioned, please consult our Sales Network Organization. Seals A Series Nitrile (una-n) compatible with mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 6743/4) water - based emulsions (types HFAE-HFAS as per ISO 6743/4) water - glycol (types HF as per ISO 6743/4) V Series Viton compatible with synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO 6743/4) 4

5 Selection & installation information Filter element types M Series Metal mesh media, available in 25, 6, 9, 25 µm Example -,, or Please refer to individual pressure drop curves to obtain filter assembly pressure drop information The following filter sizing recommendations are based using a mineral oil fluid at 15 sus with a maximum total filter assembly (housing and filter element) pressure drop of 1.15 psi. SF2 SERIES 5-51 Safety microswitch Handwheel OUTLET Flange A ø min. 4 max Min space required for servicing SF ø ø ø D1 Optional flange 1 dimn. A Filter Assembly Flow rate Weight gpm Lbs * Port Size ** SAE /2 SAE ** Flow rates with 15 SUS fluid viscosity ** Weight including filter element INLET Filter mounting dimns 5.75 ø 5.2 M1 (3/8 UN) 4.9 ø.43 no. 4 holes Outlet Flange onnections Type A D D1 5- F1 2 SAE 3PSI/M M F2 51- F1 51- F2 2 SAE 3PSI/UN 2 1/2 SAE 3PSI/M 2 1/2 SAE 3PSI/UN /2 UN M12 1/2 UN ø 1.57 V A/F.67 V ø x1.18 E REVOLVING A/F PG.43 able entry gland A/F.75 5

6 Selection & installation information Filter element types M Series Metal mesh media, available in 25, 6, 9, 25 µm Example -,, or Please refer to individual pressure drop curves to obtain filter assembly pressure drop information The following filter sizing recommendations are based using a mineral oil fluid at 15 SUS with a maximum total filter assembly (housing and filter element) pressure drop of 1.15 psi SF2 SERIES Minimum space required for servicing min. 2 max Safety switch ød Handwheel SF H.75 Filter Assembly Flow rate gpm * Port Size SP/NPT/SAE 3 SAE Weight Lbs ** OUTLET 1/8 NPT Flange A ø.67 ø.98 ø D1 Optional flange 1 dimn. A SAE ** Flow rates with 15 SUS fluid viscosity ** Weight including filter element INLET Filter mounting dimns. (SF2-53) (SF2-54) ø 7.8 ø 8.27 (SF2-53) ø 5.9 (SF2-54) ø 7.8 (SF2-53) ø 8.27 (SF2-54) ø 9.53 (SF2-53) ø 5.95 (SF2-54) ø M 12 (7/16 UN) E Outlet Flange onnections Type A D D1 E H 53- F1 3 SAE 3PSI/M M F2 3 SAE 3PSI/UN /8 UN F1 4 SAE 3PSI/M M F2 4 SAE 3PSI/UN /8 UN ø 1.57 V A/F.67 V ø x1.18 E REVOLVING A/F PG.43 able entry gland A/F.75 7

7 Selection & installation information Filter element types M Series Metal mesh media, available in 25, 6, 9, 25 µm Example -,, or Please refer to individual pressure drop curves to obtain filter assembly pressure drop information The following filter sizing recommendations are based using a mineral oil fluid at 15 SUS with a maximum total filter assembly (housing and filter element) pressure drop of 1.15 psi. SF2 SERIES Anti back flow valve screw Minimum space required for servicing 1.8 max OUTLET Flange A Safety switch D 1.2 max ø ø SF D1 Filter Assembly Flow rate gpm * Port Size SP/NPT/SAE 2 SAE 2 1/2 SAE Weight Lbs ** Optional flange 1 dimn. A ** Flow rates with 15 SUS fluid viscosity ** Weight including filter element Filter mounting dimns. INLET (SF2-55) (SF2-51) (SF2-55) (SF2-51) ø 4.4 ø 5.35 ø 5.9 ø 7.4 (SF2-55) ø 5.15 (SF2-51) ø M8 (SF2-55) (5/16 UN) M12 (SF2-51) (7/16 UN) Outlet (SF2-55) ø 4.45 (SF2-51) ø 5.4 E Flange onnections Type A D D1 E 55- F1 2 SAE 3PSI/M M F2 2 SAE 3PSI/UN /2 UN F1 2 1/2 SAE 3PSI/M M F2 2 1/2 SAE 3PSI/UN /2 UN ø 1.57 V A/F.67 V ø x1.18 E REVOLVING A/F PG.43 able entry gland A/F.75 6

8 Selection & installation information Filter element types M Series Metal mesh media, available in 25, 6, 9, 25 µm Example -,, or Please refer to individual pressure drop curves to obtain filter assembly pressure drop information The following filter sizing recommendations are based using a mineral oil fluid at 15 SUS with a maximum total filter assembly (housing and filter element) pressure drop of 1.15 psi. max Anti back flow valve screw Minimum space required for servicing (SF2-535) 7 min. (SF2-54) 8.5 min (SF2-535) 3.9 (SF2-54) ,2 Max OUTLET FLANGE A Safety microswitch ø D Max SF ø.67 ø H D1 Optional flange 1 dimn. A SF2 SERIES Filter Assembly Flow rate gpm * Port Size SP/NPT/SAE 3 SAE 4 SAE ** Flow rates with 15 SUS fluid viscosity ** Weight including filter element Weight Lbs ** Adjustable mounting flange supplied not welded INLET (SF2-535) (SF2-54) (SF2-535) (SF2-54) ø 5.9 ø 7.8 ø 7.8 ø 9.53 Filter mounting dimns. (SF2-535) ø 7.8 (SF2-54) ø M 12 (7/16 UN) E Outlet (SF2-535) (SF2-54) ø 5.95 ø 7.13 Flange onnections Type A D D1 E H 535- F1 3 SAE 3PSI/M M F2 3 SAE 3PSI/UN /8 UN F1 4 SAE 3PSI/M M F2 4 SAE 3PSI/UN /8 UN ø 1.57 V A/F.67 V ø x1.18 E REVOLVING A/F PG.43 able entry gland A/F.75 8

9 Pressure drop information General Pressure drop versus flow rate curve information for both housing and filter elements is in accordance with ISO 3968 Filter assembly pressure drop - p Total = p Housing + p Filter element Housing pressure drop - The housing pressure drop is proportional to the fluid density Filter element pressure drop - Filter element pressure drop is proportional to kinematic viscosity therefore always check the fluid operating temperature and fluid type to obtain the working viscosity according to the following formula: p 1 Filter element = (working viscosity/brochure viscosity) x p filter element Filter assembly sizing example ustomer requires a 66 gpm filter assembly Mineral oil fluid: ISO VG 46 (212 SUS) at 4 ) - 9 micron filtration Housing pressure drop - SF2 53 with 66 gpm p =.2 psi (see curve on page 9) Filter element pressure drop (brochure viscosity) - SF2 53 A with 66 gpm p =.5 gpm (see curve on page 1) Filter element pressure drop (working viscosity) - With 212 SUS p 1 =.55 x (212/15) =.77 psi Filter assembly pressure drop p Total = p Housing + p 1 Filter element = =.79 psi* { Selection *acceptable pressure drop as per our recommendations Filter housing pressure drop SF2 5 SF2 55 SF2 51 SF2 51 SF2 53 SF2 535 The curves were obtained using a mineral oil with a density of,86 kg/dm 3. The p varies proportionally to the density /2 3 SF2 54 SF

10 Filter element pressure drop The curves were obtained using a mineral oil with a kinematic viscosity 15 SUS. The p varies proportionally to the fluid kinematic viscosity..9 SF 55.9 SF SF 53.9 SF SF SF

11 SF2 Ordering code example 5 A F1 S V This example shows how order a complete filter with features based on the customer request. Nominal sizes Filter condition indicator (Use SF 51 filter element code) S T1 V V E1 With threaded hole only With hole + plug Visual (axial vacuumeter) Visual (radial vacuumeter) Electrical (change-over contacts vacuumeter) Seals Filter elements A V Nitrile (una-n) Viton Square wire mesh Type F1 F2 1 (flange) SAE 3 PSI/M 2 SAE 3 PSI/UN 2 SAE 3 PSI Port option /2 SAE 3 PSI/M 2 1/2 SAE 3 PSI/UN 2 1/2 SAE 3 PSI SAE 3 PSI/M 3 SAE 3 PSI/UN 3 SAE 3 PSI SAE 3 PSI/M 4 SAE 3 PSI/UN 4 SAE 3 PSI S D K M Options Without microswitch, without handwheel With microswitch, without handwheel (55, 51, 535, 54) With microswitch, with nylon handwheel (5, 51, 53, 54) With microswitch, with steel handwheel (5, 51, 53, 54) Without microswitch, with nylon handwheel (5, 51, 53,54) Filter assy Element type SF 51 This example shows how order a filter element with features based on the customer request Replacement element MP Filtri - Filtration products will only be guaranteed if original MP Filtri replacement elements and spares are used Data held in this publication is given only for indicative purposes. MP Filtri reserves to introduce modifications to described items for technical or commercial reasons. opyright reserved. 11

12 Head Quarter : MP FILTRI S.p.A. Italy Via Matteotti, 2 26 Pessano con ornago (Milano) Italy Tel / Fax / sales@mpfiltri.com GREAT RITAIN MP FILTRI U.K. Ltd. ourton Industrial Park ourton on the Water Gloucestershire GL54 2HQ UK Phone: Fax: sales@mpfiltri.co.uk GERMANY MP FILTRI D GmbH Am Wasserturm 5 D Heusweiler/Holz Phone: 686/8522- Fax: 686/ mpfiltrink@aol.com FRANE MP FILTRI FRANE.P Trevoux edex Tel: Telefax: mpfiltrifrance@wanadoo.fr USA MP FILTRI USA Inc. 255 Quaker Pointe Drive Quakertown, PA Phone: Fax: mpusasales@aol.com ANADA MP FILTRI ANADA Inc. 21 Jacob Keffer Parkway oncord, Ontario anada L4K 4W3 Phone: Fax: mail@mpfiltricanada.com

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm SERIES SF2-250 SUCTION FILTER Flow rate to 45 gpm D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

D e s c r i p t i o n

D e s c r i p t i o n D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHP series filters are designed for high pressure line applications and are suitable for in-line installation. Continued research and development on both the filter bodies and the

More information

MPF filters within this range are suitable for flow rates up to 750 l/min.

MPF filters within this range are suitable for flow rates up to 750 l/min. D e s c r i p t i o n MPF series filters are designed for return lines, and are installed semi-immersed in a reservoir. Continued Research & Development on both the filter bodies and the filter elements

More information

SPIN-ON FILTER - LOW PRESSURE LINE

SPIN-ON FILTER - LOW PRESSURE LINE SERIES MSH SPIN-ON FILTER - LOW PRESSURE LINE Maximum working pressure 5 psi Flow rate to 8 GPM D e s c r i p t i o n MSH working pressure of 5 psi, with a peak pressure This filter MSH series utilises

More information

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min INLIN FILTR Maximum working pressure 0 bar Flow rate to 00 l/min R.F. Filter Symbol without bypass Filter Symbol with Reverse Flow R.F. Filter Symbol with bypass Filter Symbol with bypass & Reverse Flow

More information

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHB series filters are designed for pressure line applications where manifold mounting is a specific requirement. The manifold type filters are designed to integrate onto manifold

More information

D e s c r i p t i o n

D e s c r i p t i o n e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed (MPH) or totally immersed into

More information

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 12 bar Flow rates to 3 l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for

More information

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n RF2 96 Maximum pressure 20 bar F l o w r a t e s t o 4 5 5 l / m i n Filter housing (Materials) Filter body: luminium over: Nylon Valve: Nylon - Steel nti-emptying valve: Steel Pressure Working pressure:

More information

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a New Headquarters : MP FILTRI S.p.. Italy Via 1 Maggio, n. 3 Pessano con Bornago (Milano) Italy Tel. +39./973.1 Fax +39./9741497-974188 email: sales@mpfiltri.com http://www.mpfiltri.com GRT BRITIN MP FILTRI

More information

THE IMPORTANCE OF AN EFFICIENT FILTRATION

THE IMPORTANCE OF AN EFFICIENT FILTRATION In line high pressure filters HF 745 / HF 748 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the

More information

In line high pressure filters. HF 735 series

In line high pressure filters. HF 735 series In line high pressure filters HF 735 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

In line high pressure filters. HF 725 series

In line high pressure filters. HF 725 series In line high pressure filters HF 725 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

Fluid Cooling Industrial COLW Series

Fluid Cooling Industrial COLW Series Fluid Cooling Industrial COLW Series 0916 COPPER & STEEL CONSTRUCTION Performance Notes Ideal for independent cooling and filtering of system oils Utilizes a high efficient EK series shell & tube (finned

More information

SERIES. Maximum pressure 110 bar

SERIES. Maximum pressure 110 bar SERIES Maximum pressure 0 bar F l o w r a t e s t o 9 5 l / m i n Technical data FMP 09 Compatibility Filter housing (Materials) Head: nodized aluminium Housing: nodized aluminium Bypass valve: Steel Pressure

More information

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:

More information

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data Filter housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:

More information

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW FILTERS HYDRAULIC DIVISION - Suction filters SD TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW SPARE PARTS ORDERING INFORMATION DINSIONS OF

More information

NEW. High Pressure filters. FMM 150 series. Maximum pressure up to 420 bar - Flow rate up to 250 l/min

NEW. High Pressure filters. FMM 150 series. Maximum pressure up to 420 bar - Flow rate up to 250 l/min NEW High Pressure filters FMM 50 series Maximum pressure up to 0 bar - Flow rate up to 50 l/min PASSION TO PERFORM FILTER SIZING THE CORRECT FILTER SIZING HAVE TO BE BASED ON THE TOTAL PRESSURE DROP DEPENDING

More information

In line high pressure filters. HF HF 761 series

In line high pressure filters. HF HF 761 series In line high pressure filters HF 76 - HF 761 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the

More information

THE IMPORTANCE OF AN EFFICIENT FILTRATION

THE IMPORTANCE OF AN EFFICIENT FILTRATION Tank mounted return line filters HF 554 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

Filter. Rücklauffilter 3-Loch Serie HF 502. Bestellnr. Innengewinde G. Code. Typ. (ohne Filterelement)

Filter. Rücklauffilter 3-Loch Serie HF 502. Bestellnr. Innengewinde G. Code. Typ. (ohne Filterelement) Filter Bestellnr. (ohne Filterelement) Typ Innengewinde G Code Rücklauffilter 3-Loch Serie HF 52 3-4- HF52-.6-GD-B-H-Z-XD-DA /2 HHRK62 3-4-5 HF52-2.77-GD-B-H-Z-XD-DA /2 HHRK22 3-4- HF52-2.77-GE-B-H-Z-XD-DA

More information

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181 Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:

More information

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters Return fi lters series Maximum pressure up to bar - Flow rate up to 15 l/min 193 Return fi lters GENERAL INFORMATION Technical data Return filter Maximum pressure up to bar - Flow rate up to 15 l/min Filter

More information

FHA 051 Working pressure 6000 psi

FHA 051 Working pressure 6000 psi 6 SRIS Working pressure 6000 psi Style S Style Style T Style D Style V Style Z D.I. 7 8 Technical data Filter body (Materials) Head: Steel (chemical heat treatment) Housing: Steel (chemical heat treatment)

More information

FMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I.

FMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I. 30 FMM 050 SRIS FMM 050 Working pressure 0 bar Style S Style Style T Style D 3 3 Technical data Filter body (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel (chemical heat treatment)

More information

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron NF filters are designed for inline mounting and as tank-top mounted return line filters. These filters can also be used on filling, flushing and off-line units. Inline Filters NF Flow rates up to 3,500

More information

THE IMPORTANCE OF AN EFFICIENT FILTRATION

THE IMPORTANCE OF AN EFFICIENT FILTRATION Tank mounted return line filters HF 57 / HF 575 / HF 578 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants

More information

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters Stainless steel high pressure fi lters FZP series Maximum pressure up to 0 bar 55 Stainless steel high pressure filters FILTER SIZING The correct filter sizing have to be based on the variable pressure

More information

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Return Line Filter HF4R up to 450 l/min, up to 10 bar Return Line Filter HF4R up to 450 l/min, up to 10 bar 9" 18" 27" 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international regulations.

More information

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:

More information

Flow rates to 500 l/min

Flow rates to 500 l/min FF 5 Filter housing in according to SE J066 for F filter elements Maximum pressure 50 bar Flow rates to 500 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing:

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:

More information

LMP series

LMP series Low & Medium Pressure fi lters LMP 95-95-95 series Maximum working pressure up to.5 MPa (5 bar) - Flow rate up to 000 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request) HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to

More information

Filter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ

Filter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ Filter Bestellnr. (ohne Filterelement) Typ Innengewinde G Code Spin-on Filter Serie HF 62 3-2-1 HF62.2-B-GE-XA-DA-XB-DA HHT384 3-2-15 HF62.2-B2-GE-XA-DA-XB-DA 3/4 HHT3163 3-2-11 HF62.2-B17-GE-XA-DA-XB-DA

More information

OIL FILLER AND AIR BREATHER FILLER CAPS

OIL FILLER AND AIR BREATHER FILLER CAPS OIL FILLER ND IR RETHER FILLER CPS The complete series of oil filter and makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. s perform

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to

More information

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T 3.10.5.1) Burst 330 bar (4800 psi) (acc. to NFPA T 3.10.5.1) Housing

More information

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1.5.1): F1-XD4/63/1: 1 bar (15 psi) F1-XD16/25/4: 8 bar (12 psi) Housing Burst (acc. to

More information

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S.. Suction Filter /M/F and Suction Filter Elements S/S.. up to 500 l/min Filters: 60 110 160 240 330 M 330 F 400 F 500 Elements: S SH. SU. SG. 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The

More information

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min Low & Medium Pressure filters LDP & series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE

More information

Filter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ

Filter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ Filter Bestellnr. (ohne Filterelement) Typ Innengewinde G Code Spin-on Filter Serie HF 620-1000 HF620.20-B00-GE-XA-DA-XB-DA HHT03084-1050 HF620.20-B02-GE-XA-DA-XB-DA 3/4 HHT03163-1100 HF620.20-B17-GE-XA-DA-XB-DA

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 2500 l/min, up to 315 bar 30 60 110 140 160 240 280 330 500 660 1.x 660 2.x 990 2.x 1320 2.x 1320 3.x 2640 3.x 3960 3.x 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING

More information

Return Line Filter RF

Return Line Filter RF Return Line Filter up to 15000 l/min, up to 25 bar 30 60 110 160 240 330 450 580 660 950 1300 2500 4000 5200 6500-7800 15000 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings

More information

The range of products is completed by a number of accessories, including:

The range of products is completed by a number of accessories, including: ACCESSORIES The range of products is completed by a number of accessories, including: Foot brackets, which serve to support the motor-and-pump unit in the event that the selected electric motor does not

More information

Series TSW Sheet No J. SUCTION FILTER, horizontal tank mounted. Dimensions: mounting surface

Series TSW Sheet No J. SUCTION FILTER, horizontal tank mounted. Dimensions: mounting surface SUCTION FILTER, horizontal tank mounted Sheet No. 1905 J Series TSW 210-310 Dimensions: type TSW 210 TSW 310 connection - 20 SAE -20 SAE A 12.09 15.47 B 11.57 14.96 C 11.42 14.76 D 8.62 12.00 E.26.30 weight

More information

Return Line Filter RF

Return Line Filter RF HYDAC return line filters type RF are designed to be mounted directly on tank tops. Inline mounting is also possible. Return Line Filter RF Flow rates up to 5, l/min Pressure range up to 25 bar Material:

More information

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min Low & Medium Pressure filters & series Maximum pressure up to 60 bar Flow rate up to 0 l/min DIN 550 09 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters High Pressure fi lters FHF5 series Maximum pressure up to 50 bar Flow rate up to 500 l/min housing according to SAE J066 for HF filter s 95 High Pressure fi lters FILTER SIZING The correct filter sizing

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION F4-DMD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1..1): F4-DMD/8/11: 7 bar (11 psi) F4-DMD1/3/4: 4 bar (8 psi) Housing Burst

More information

Flow rates to 3000 l/min

Flow rates to 3000 l/min MPH Maximum pressure bar Flow rates to l/min echnical data housing (Materials) Head: luminium: MPH nodised luminium: MPH 68 Painted luminium: MPH 66 Cover: Nylon: MPH luminium: MPH nodised luminium: MPH

More information

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi) HYDRAULIC FILTRATION F8-D1 series In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x:

More information

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T ) HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Housing

More information

Pressure Filter DF...K P, DF...M P, Flange Mounted

Pressure Filter DF...K P, DF...M P, Flange Mounted Pressure Filter, DF...M P, Flange Mounted up to 550 l/min, up to 260 bar DF...M P 330...1.X 160 240 280 500...1.X 660...1.X 660...2.X 990...2.X 1320...2.X 660...3.X 990...3.X 1320...3.X 1. TECHNICAL SPECIFICATIONS

More information

HIGH PRESSURE FILTERS Series HF2P

HIGH PRESSURE FILTERS Series HF2P HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,

More information

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar RFL inline filters are designed for inline mounting in hydraulic and lubrication systems. Inline Filter RFL Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar * For larger flow rates,

More information

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW ILTERS HYDRAULIC DIVISIO TAK CARE - Return filters RC TECHICAL DATA ORDERIG AD OPTIOS CHART CLOGGIG IDICATORS PRESSURE DROP ( p) CURVES CROSS UCTIOAL VIEW SPARE PARTS ORDERIG IORMATIO DIMESIOS O THE ILTER

More information

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF up to 600 l/min, up to 315 bar 60 110 140 160 240 280 330 500 660 1.X 660 2.X 990 1320 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING

More information

SPIN-ON FILTERS & ELEMENTS

SPIN-ON FILTERS & ELEMENTS ABSOLUTE RATED (BETA SPIN ) & NOMINAL RATED SPIN-ON FILTERS & ELEMENTS Single and Twin Element Models Pressures to 20 psi Flows to 120 gpm APPLICATION HYDAC Spin-On Filters are for filtration of hydraulic

More information

The range of products is completed by a number of accessories, including:

The range of products is completed by a number of accessories, including: ACCESSORIES The range of products is completed by a number of accessories, including: Foot brackets, which serve to support the motor-and-pump unit in the event that the selected electric motor does not

More information

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01. Change-Over Inline Filter RFLD Cast Version Flow Rates up to 3 l/min* Pressure Range 25/4/64 bar With Ball Change-Over Valve * For higher flow rates, please refer to brochure RFLD Welded Version E 7.9.2/.4

More information

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

Filtering elements differential collapsing pressure tested in compliance with ISO 2941: DESCRIPTION Many years of in-field experience have shown the necessity of more and more efficient controls on the contamination level of hydraulic fluids and fuels. With this goal uppermost in its mind,

More information

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min Low & Medium Pressure fi lters LMP - series Maximum pressure up to 8 bar - Flow rate up to l/min 5 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

Return Line Filter RFM with 4-Hole Mounting

Return Line Filter RFM with 4-Hole Mounting Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 210 270 330 500 600 661 851 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX up to 2000 l/min, up to 420 bar DF/DFF...1.X/2.X 30 60 110 140 160 240 280 330 500 660 990 1320 1500 2000 3000 4000 DF...3.X DFFX...1.X/2.X

More information

High-pressure inline filter, flangeable

High-pressure inline filter, flangeable High-pressure inline filter, flangeable RE 51405/08.08 1/1 Types FEN 0040 to 1000; FE 0003, 0015, 0018 Nominal size according to DIN 4550: 0040 to 1000 Nominal size according to BRFS: 0003, 0015, 0018

More information

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass COMPONENTS RC MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2002) Max working:

More information

Working pressure. 350 bar. Style B Series FHD 051. Series FHD 325/332 D.I. D.I. D.I. A A

Working pressure. 350 bar. Style B Series FHD 051. Series FHD 325/332 D.I. D.I. D.I. A A 98 FD SRIS FD Working pressure 350 bar Style S Style Series FD 05 Style Series FD 35/33 D.I. D.I. D.I. 99 Technical data body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical

More information

Line filter with filter element according to DIN 24550

Line filter with filter element according to DIN 24550 Line filter with filter element according to DIN 2455 RE 51423/9.12 Replaces: 7.1 1/2 Type 445LEN4 to 1 Size according to DIN 2455: 4 to 1 Nominal pressure: 45 bar [6527 psi] Connection up to G 1 1/2;

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 45 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold

More information

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass COMPONENTS RB MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2) Max working: 0 kpa

More information

Series RFL In-Line Filter

Series RFL In-Line Filter APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction

More information

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 36 psi up to 4 gpm Hydraulic Symbol A D2 Features RF 3 filters are constructed of polyamide plastic. RF 6-33 filters are constructed of aluminum

More information

Change-Over Inline Filter RFLD Welded Version

Change-Over Inline Filter RFLD Welded Version Change-Over Inline Filter RFLD Welded Version up to 15000 l/min, up to 16 bar RFLD 1300 CAS to RFLD 15000 CBW 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed

More information

Return / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters

Return / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters Return / Suction fi lters mounted MRSX series Maximum pressure up to bar Flow rate up to l/min 9 Return / Suction fi lters FILTER SIZG The correct filter sizing have to be based on the variable pressure

More information

Return Line Filter RFM with 4-Hole Mounting

Return Line Filter RFM with 4-Hole Mounting Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 195 210 270 330 500 600 661 851 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar 160 240 260 280 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international

More information

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure Inline filters up to 3500 l/min, up to 25 bar 160 240 280 330 500 750 950 1350 2650 on request 1310 2.x on request 2610 2.x 1340 2640 5240 7840 10440 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S..

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S.. Suction Filter /M/F and Suction Filter Elements S and S.. up to 500 l/min Filters: 60 100 160 240 330 M 330 F 400 F 500 Elements: S SH. SU. SG. 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

STAUFF STAUFF. Local solutions for individual customers worldwide. Return Line Filters RTF FILTRATION TECHNOLOGY. Ordering Code # :SFT A - UK

STAUFF STAUFF. Local solutions for individual customers worldwide. Return Line Filters RTF FILTRATION TECHNOLOGY. Ordering Code # :SFT A - UK STAUFF THIS IS STAUFF RESPONSE AND FLEXIBILITY COMPETENT SERVICE PROMPT DELIVERY ENSURED QUALITY FRIENDLY SERVICE PROVEN IN PRACTICE Australia Stauff Corporation (Pty.) Ltd. P.O.Box 227, Unanderra Wollongong,

More information

Block mounting filter, for lateral flange-mounting

Block mounting filter, for lateral flange-mounting Block mounting filter, for lateral flange-mounting RE 51419/2.1 1/18 Type 35PSFN4 to 1; 35PSF13, 15 Size according to DIN 2455: 4 to 1 Additional sizes: 13, 15 Nominal pressure 35 bar [579 psi] Port up

More information

Block mounting filter, for lateral flange-mounting

Block mounting filter, for lateral flange-mounting Block mounting filter, for lateral flange-mounting RE 51418/12.1 Replaces: 1.1 1/18 Type 245PSFN4 to 4; 245PSF13, 15 Size according to DIN 2455: 4 to 4 Additional sizes: 13, 15 Nominal pressure 25 bar

More information

Series RFLD Duplex In-Line Filter

Series RFLD Duplex In-Line Filter APPLICATION Series RFLD Duplex In-Line Filter Welded Pressures to 230 psi Flows to 3900 gpm HYDAC RFLD in-line filters are designed for in-line mounting and are mainly used in continuously operating systems.

More information

Block mounting filter, lateral flange-mounting possible

Block mounting filter, lateral flange-mounting possible Block mounting filter, lateral flange-mounting possible RE 0/.0 Replaces: 0.09 / Types 0/0 FEN 000 to 000; 0/0 FE 000, 00, 008 Nominal sizes according to DIN 0: 000 to 000 Nominal sizes according to BRFS:

More information

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters igh Pressure fi lters FP series Maximum pressure up to bar Flow rate up to 7 l/min igh Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending

More information

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04 Inline Filter MFM Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS 400-15 / steel 1. TECHNICAL SPECIFICATIONS 1.1. FILTER HOUSING Construction The inline filter consists of a filter

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 4 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold block

More information

Duplex Pressure Filters

Duplex Pressure Filters Duplex Pressure Filters Series DFDK Ball Valve Selector Pressures to 45 psi Flows to 9 gpm APPLICATIONS HYDAC DFDK Duplex Filters are ideal for use on hydraulic test equipment, robots, or other critical

More information

Oil Solutions. Tank Top Return Filters RTF. Local solutions for individual customers worldwide FILTRATION TECHNOLOGY

Oil Solutions. Tank Top Return Filters RTF. Local solutions for individual customers worldwide FILTRATION TECHNOLOGY Oil Solutions FILTRATION TECHNOLOGY Tank Top Return Filters RTF Local solutions for individual customers worldwide www.oilsolutions.com.au sales@oilsolutions.com.au Distributor Walter Stauffenberg GmbH

More information

Block mounting filter, for vertical flange-mounting

Block mounting filter, for vertical flange-mounting Block mounting filter, for vertical flange-mounting RE 51417/12.1 Replaces: 7.1 1/18 Type 45PBFN4 to 1; 45PBF13, 15 Size according to DIN 2455: 4 to 1 Additional sizes: 13, 15 Nominal pressure 45 bar [653

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Side Mounting Series DF...QE Pressures to 4 psi Flows to 18 gpm HYDAC DF...QE High Pressure Filters are designed to be side mounted directly onto the

More information

Change-Over Inline Filter RFLD Weld Version

Change-Over Inline Filter RFLD Weld Version Change-Over Inline Filter RFLD Weld Version up to 15000 l/min, up to 16 bar RFLD 1300 CAS to RFLD 15000 CBW 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The fi lter housings are designed

More information

Inline filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550 Inline filter with filter element according to DIN 24550 RE 51421/07.11 Replaces: 12.10 1/16 Type 245LEN0040 to 400; 245LE0130, 0150 Size according to DIN 24550: 0040 to 0400 Additional sizes: 0130, 0150

More information

Suction Filters S8-455 SE56-560

Suction Filters S8-455 SE56-560 Industrial Filters ccumulators uction Filters 8-5 E56-56 Filters for installation in suction pipes uctions filters with housing for tank mounting uction filters with housing including automatic shut off

More information

Inline filter. Features RE 51401/ Types 40 FLEN 0160 to 1000; 40 FLE 0045, 0055, 0120 to 0270

Inline filter. Features RE 51401/ Types 40 FLEN 0160 to 1000; 40 FLE 0045, 0055, 0120 to 0270 Inline filter RE 5101/08.08 1/10 Types 0 FLEN 0160 to 1000; 0 FLE 005, 0055, 010 to 070 Nominal size according to DIN 550: 0160 to 1000 Nominal size according to BRFS: 005, 0055, 010 to 070 Nominal pressure

More information

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Suction Filters LS 025 LS 035 In-line mounting Connection up to G¾ / -2 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Description Application To be installed in the suction line of the pumps of hydraulic

More information