1 A series Switches & Pilot ights

2 ø16 ø12 ø10 ø8 A Series Selection Guide Series A6 Series Switches and Pilot ights Mounting Hole Size ø16 Model A6 AB6 AS6 AS6 (key) Disc tumbler key Shape Wave key Unit Illuminated Pushbuttons (, ) Pilot ight Pushbuttons (, ) Selector Switch (90 2-position maintained, 90 2-position spring return, 4 3-position maintained, 4 3-position spring return) Key Selector Switch (90 2-position maintained, 90 2-position spring return, 4 3-position maintained, 4 3-position spring return) Bezel Size (mm) ø ø Bezel olor ight Source ED amp (IDE s ATD) Black Button/Illumination olor Illumination: amber, blue, green, pure white, red, white, yellow Button: black, blue, green, red, white, yellow ens: amber, blue, green, red, yellow, white Knob: black Key cylinder: chrome plating (metal) ontact onfiguration SPDT, DPDT (Gold-clad silver contact) ontact ating (resistive load) 110V A/1A, 24V D/1A Electrical : 100,000 operations minimum : 0,000 operations minimum Mechanical : 1,000,000 operations minimum : 100,000 operations minimum Degree of Protection IP6, IP40 (IE 6029) ontact Durability Terminal Style Accessories Solder terminal 100,000 operations minimum 20,000 operations minimum Switch Guard Yes Yes Socket Yes Yes Yes Yes Terminal over Yes Yes Yes Yes Dust over Yes Yes Mounting Hole Plug Yes Yes Yes Yes emarks ED lamps contain a current-limiting resistor and a pro tection diode. Available with threesided barrier. Available with threesided barrier. Operator position can be changed by IDE s original bezel rotating and locking system. Approvals Page

3 A Series Selection Guide ø16 ø12 ø10 ø8 Series A Series Switches and Pilot ights Mounting Hole Size ø12 ø10 ø8 Model A2 AB2 A1 AB1 A8 AB8 Shape Unit Illuminated Pushbuttons (, ) Pilot ight Pushbuttons (, ) Illuminated Pushbuttons (, ) Pilot ight Pushbuttons (, ) Illuminated Pushbuttons (, ) Pilot ight Pushbuttons (, ) Bezel Size (mm) ø ø ø Bezel olor Black Black Black ight Source Button/Illumination olor ontact Durability ontact onfiguration ontact ating (resistor load) Electrical Mechanical ED lamp (IDE s AD-S) Illumination: amber, green, red, white, yellow Button: black, blue, green, red, white, yellow ens: amber, blue, green, red, yellow, white ED lamp (IDE s AD-S) Illumination: amber, green, red, white, yellow Button: black, blue, green, red, white, yellow ens: amber, blue, green, red, yellow, white ED lamp (IDE s AD-S) Illumination: amber, green, red, white, yellow SPDT, DPDT (silver contact) SPDT (silver contact) SPDT (silver contact) 110V A/1A, 24V D/1A 110V A/1A, 24V D/1A 110V A/1A, 24V D/1A : 100,000 operations minimum : 0,000 operations minimum : 200,000 operations minimum : 100,000 operations minimum : 100,000 operations minimum : 0,000 operations minimum : 200,000 operations minimum : 100,000 operations minimum Button: black, blue, green, red, white, yellow ens: amber, blue, green, red, yellow, white : 100,000 operations minimum : 0,000 operations minimum : 200,000 operations minimum : 100,000 operations minimum Degree of Protection IP6, IP40 (IE 6029) IP40 (IE 6029) IP40 (IE 6029) Terminal Style Solder terminal Solder terminal Solder terminal Switch Guard Yes Yes Yes Socket Yes Yes Yes Terminal over Yes Yes Yes Dust over Yes Mounting Hole Plug Yes Yes Yes Accessories emarks Approvals External current-limiting resistor type (Note) External current-limiting resistor type (Note) External current-limiting resistor type (Note) (except for pilot lights) (except for pilot lights) (except for pilot lights) Page Note: ED lamps do not contain a current-limiting resistor, and external resistors must be connected. 3

4 ø16 A6 Series Switches and Pilot ights ight duty in short 22mm body length. Features IDE s original mechanism for snap-action switching. Suitable for a wide variety of office and factory aplications. The ED lamp contains a current-limiting resistor and a diode for protection against reverse connection. Degree of protection: IP40 and IP6 (IE 6029) U recognized, SA certified, EN compliant, and approved. Applicable Standards Mark File No. or Organization U08 U ecognition File No. E996 SA 22.2 No.14 SA File No EN GB ED amp atings (ATD) EU ow Voltage Directive (switches) (pilot lights) ontact atings (ontact Block) ated Insulation Voltage 20V ated Thermal urrent 3A Operating Voltage (A/D) 12V 24V 110V 220V A 0/60 Hz esistive oad 1.0A 0.A Inductive oad 0.7A 0.A D esistive oad 1.0A 1.0A 0.2A Inductive oad 0.7A 0.7A 0.A ontact Material Gold-clad silver Minimum applicable load: V A/D, 1 ma (applicable range may vary with operating conditions and load types) Weight (example) Weight (approx.) A6M-M24: 8g A6M-M221: 46g A6M-P4: 6g A6M-P21: 4g AB6M-M2: 7g AS6M-2Y2: 9g AS6M-2KT2A: 21g Specifications Operating Temperature Storage Temperature Operating Humidity ontact esistance Insulation esistance Dielectric Strength Switch Unit Illumination Unit Vibration esistance Shock esistance Mechanical Durability (minimum operations) Electrical Durability (minimum operations) 2 to + (no freezing) 30 to +80 (no freezing) 4 to 8% H (no condensation) 0 mω maximum (initial value) 100 MΩ minimum (00V D megger) Between live and dead metal parts: 2,000V A, 1 minute Between terminals of different poles: 2,000V A, 1 minute Between terminals of the same pole: 1,000V A, 1 minute Between contact and lamp terminals: 1,00V A, 1 minute Between live part and ground: 2,000V A, 1 minute Operating extremes: to Hz, amplitude 0.7 mm Damage limits: 00 m/s 2 (0G) Operating extremes: 200 m/s 2 (20G) : 1,000,000 operations : 100,000 operations Pushlock Turn eset: 100,000 operations Selector Switch: 20,000 operations Key Selector Switch: 20,000 operations Other than : 100,000 operations : 0,000 operations (Switching frequency 1200 operations/h) Degree of Protection IP40, IP6 (IE 6029) Terminal Style Solder terminal Part No. ATD-➁ ATD-1➁ ATD-2➁ amp Base Exclusive for A series Voltage ange V D ±% 12V A/D ±10% 24V A/D ±10% ated Voltage V D 12V A/D 24V A/D urrent Draw A 9 ma 9 ma D 8 ma 8 ma 8 ma olor ode ➁ A (amber), G (green), JW (pure white), (red), S (blue), W (white) amp Base olor Same as illumination color (except JW - gray base) Voltage Marking Die stamped on the base ife (reference value) Approx. 0,000 hours (The luminance is reduced to 0% of the initial intensity when used on complete D.) Internal ircuit (+) ( ) ED hip Protection Diode Zener Diode Specify a color code in place of ➁ in the Part No. A (amber), G (green), JW (pure white), (red), S (blue), W (white) Use a pure white (JW) ED lamp for yellow illumination. 4

5 A6 Series Illuminated Pushbuttons ø16 Illuminated Pushbuttons Package Quantity: 1 Shape Operation Operating Part No. ontact ➁ Illumination Voltage IP40 IP6 olor ode ound SPDT A6M-M11➁ A6M-M11P➁ A6M V D ±% DPDT A6M-M21➁ A6M-M21P➁ 12V A/D SPDT A6M-M13➁ A6M-M13P➁ ±10% DPDT A6M-M23➁ A6M-M23P➁ 24V A/D SPDT A6M-M14➁ A6M-M14P➁ ±10% DPDT A6M-M24➁ A6M-M24P➁ V D ±% SPDT A6M-A11➁ A6M-A11P➁ DPDT A6M-A21➁ A6M-A21P➁ 12V A/D SPDT A6M-A13➁ A6M-A13P➁ ±10% DPDT A6M-A23➁ A6M-A23P➁ 24V A/D SPDT A6M-A14➁ A6M-A14P➁ ±10% DPDT A6M-A24➁ A6M-A24P➁ SPDT A6Q-M11➁ A6Q-M11P➁ A6Q V D ±% DPDT A6Q-M21➁ A6Q-M21P➁ 12V A/D SPDT A6Q-M13➁ A6Q-M13P➁ ±10% DPDT A6Q-M23➁ A6Q-M23P➁ 24V A/D SPDT A6Q-M14➁ A6Q-M14P➁ ±10% DPDT A6Q-M24➁ A6Q-M24P➁ V D ±% SPDT A6Q-A11➁ A6Q-A11P➁ DPDT A6Q-A21➁ A6Q-A21P➁ 12V A/D SPDT A6Q-A13➁ A6Q-A13P➁ Specify a color code ±10% DPDT in place of ➁ in the A6Q-A23➁ A6Q-A23P➁ Part No. 24V A/D SPDT A6Q-A14➁ A6Q-A14P➁ ±10% DPDT A6Q-A24➁ A6Q-A24P➁ A: amber ectangular SPDT A6H-M11➁ A6H-M11P➁ JW: pure white A6H V D ±% DPDT A6H-M21➁ A6H-M21P➁ : red S: blue 12V A/D SPDT A6H-M13➁ A6H-M13P➁ ±10% DPDT A6H-M23➁ A6H-M23P➁ 24V A/D SPDT A6H-M14➁ A6H-M14P➁ ±10% DPDT A6H-M24➁ A6H-M24P➁ V D ±% SPDT A6H-A11➁ A6H-A11P➁ DPDT A6H-A21➁ A6H-A21P➁ 12V A/D SPDT A6H-A13➁ A6H-A13P➁ ±10% DPDT A6H-A23➁ A6H-A23P➁ 24V A/D SPDT A6H-A14➁ A6H-A14P➁ ±10% DPDT A6H-A24➁ A6H-A24P➁ ectangular SPDT A6G-M11➁ A6G-M11P➁ w/three-sided barrier V D ±% A6G DPDT A6G-M21➁ A6G-M21P➁ 12V A/D SPDT A6G-M13➁ A6G-M13P➁ ±10% DPDT A6G-M23➁ A6G-M23P➁ 24V A/D SPDT A6G-M14➁ A6G-M14P➁ ±10% DPDT A6G-M24➁ A6G-M24P➁ V D ±% SPDT A6G-A11➁ A6G-A11P➁ DPDT A6G-A21➁ A6G-A21P➁ 12V A/D SPDT A6G-A13➁ A6G-A13P➁ ±10% DPDT A6G-A23➁ A6G-A23P➁ 24V A/D SPDT A6G-A14➁ A6G-A14P➁ ±10% DPDT A6G-A24➁ A6G-A24P➁ See page 7 for dimensions. See page 20 for marking plate size and engraving area. When using white lens unit (clear lens + white marking plate) with color codes A, G,, or S, specify W before ➁ in the Part No. (without marking) Example: A6H-M24W➁ A pure white (JW) ED lamp is used for yellow illumination.

6 ø16 A6 Series Pilot ights Pilot ights ound A6M-P Shape Part No. Operating Voltage IP40 IP6 V D ±% A6M-P1➁ A6M-P1P➁ Package Quantity: 1 ➁ Illumination olor ode 12V A/D ±10% A6M-P3➁ A6M-P3P➁ 24V A/D ±10% A6M-P4➁ A6M-P4P➁ A6Q-P V D ±% A6Q-P1➁ A6Q-P1P➁ ectangular A6H-P 12V A/D ±10% A6Q-P3➁ A6Q-P3P➁ 24V A/D ±10% A6Q-P4➁ A6Q-P4P➁ V D ±% A6H-P1➁ A6H-P1P➁ Specify a color code in place of ➁ in the Part No. A: amber JW: pure white : red S: blue 12V A/D ±10% A6H-P3➁ A6H-P3P➁ 24V A/D ±10% A6H-P4➁ A6H-P4P➁ ectangular w/three-sided barrier A6G-P V D ±% A6G-P1➁ A6G-P1P➁ 12V A9D ±10% A6G-P3➁ A6G-P3P➁ 24V A/D ±10% A6G-P4➁ A6G-P4P➁ See page 7 for dimensions. See page 20 for marking plate size and engraving area. When using white lens unit (clear lens + white marking plate) with color codes A, G,, or S, specify W before ➁ in the Part No. (without marking) Example: A6H-M24W➁ A pure white (JW) ED lamp is used for yellow illumination. 6

7 A6 Series Illuminated Pushbuttons and Pilot ights Dimensions ø16 Dimensions (Illuminated Pushbuttons & Pilot ights) Terminal Width t ubber Gasket Panel Thickness 0. to 6 Anti-rotation ing 2. 3 ectangular ocking ing ectangular w/3-way barrier ound ø18 18 Pilot ight 6 6 Illuminated Pushbutton Terminal Arrangement (bottom view) Illuminated Pushbutton Pilot ight N1 N2 NO1 NO2 amp Terminal (+) 1 2 amp Terminal ( ) amp Terminal (+) amp Terminal ( ) Mounting Hole ayout ound/ ø With contact: N1, NO1, 1 terminal only ectangular ectangular w/3-way barrier ø min. 18 min. Note: Determine mounting centers to ensure easy operation. 18 min. 24 min. All dimensions in mm. 7

8 ø16 A6 Series Pushbuttons Pushbuttons ound AB6M AB6Q ectangular AB6H Package Quantity: 1 Shape Button Style Operation ontact Part No. IP40 IP6 olor ode ➀➁ Button SPDT AB6M-M1➀ AB6M-M1P➀ B black DPDT AB6M-M2➀ AB6M-M2P➀ : red SPDT AB6M-A1➀ AB6M-A1P➀ S: blue DPDT AB6M-A2➀ AB6M-A2P➀ ens SPDT AB6M-M1➁ AB6M-M1P➁ A: amber DPDT AB6M-M2➁ AB6M-M2P➁ : red SPDT AB6M-A1➁ AB6M-A1P➁ S: blue DPDT AB6M-A2➁ AB6M-A2P➁ Button SPDT AB6Q-M1➀ AB6Q-M1P➀ B black DPDT AB6Q-M2➀ AB6Q-M2P➀ : red SPDT AB6Q-A1➀ AB6Q-A1P➀ S: blue DPDT AB6Q-A2➀ AB6Q-A2P➀ ens SPDT AB6Q-M1➁ AB6Q-M1P➁ A: amber DPDT AB6Q-M2➁ AB6Q-M2P➁ : red SPDT AB6Q-A1➁ AB6Q-A1P➁ S: blue DPDT AB6Q-A2➁ AB6Q-A2P➁ Button SPDT AB6H-M1➀ AB6H-M1P➀ B black DPDT AB6H-M2➀ AB6H-M2P➀ : red SPDT AB6H-A1➀ AB6H-A1P➀ S: blue DPDT AB6H-A2➀ AB6H-A2P➀ ens SPDT AB6H-M1➁ AB6H-M1P➁ A: amber DPDT AB6H-M2➁ AB6H-M2P➁ : red SPDT AB6H-A1➁ AB6H-A1P➁ S: blue DPDT AB6H-A2➁ AB6H-A2P➁ Button SPDT AB6G-M1➀ AB6G-M1P➀ B black DPDT AB6G-M2➀ AB6G-M2P➀ : red SPDT AB6G-A1➀ AB6G-A1P➀ S: blue DPDT AB6G-A2➀ AB6G-A2P➀ ens SPDT AB6G-M1➁ AB6G-M1P➁ A: amber DPDT AB6G-M2➁ AB6G-M2P➁ : red SPDT AB6G-A1➁ AB6G-A1P➁ S: blue DPDT AB6G-A2➁ AB6G-A2P➁ ectangular w/three-sided barrier AB6G Specify a color code in place of ➀ or ➁ in the Part No. See page 9 for dimensions. See page 20 for marking plate size and engraving area. Black is available for lens style buttons. Black lens consists of a clear lens and a black marking plate. Specify B in place of ➁ in the Part No. Example:AB6H-M2B 8

9 A6 Series Pushbuttons ø16 Dimensions Pushbutton ubber Gasket Terminal Width t Anti-rotation ing 2. 3 ocking ing Panel Thickness 0. to 6 ectangular ectangular w/3-way barrier ound ø Mounting Hole ayout ound/ ø ectangular ectangular w/3-way barrier ø Terminal Arrangement (bottom view) Pushbutton 18 min. 18 min. Note: Determine mounting centers to ensure easy operation. N1 NO1 N2 NO2 18 min. 24 min. 1 2 Note: SPDT has only N1, NO1, and 1 terminals. All dimensions in mm. 9

10 ø16 A6 Series Selector Switches Selector Switches Operator position can be changed by IDE s original bezel rotating and locking system. The bezel can be locked at every 4 and bezel rotation is prevented while mounting on a panel. Example: 3-position () () () Normal Operator Position () How to change the operator position Pull out the bezel to release the lock. otate the bezel, and push it in at 4 intervals to lock the bezel. Dimensions Package Quantity: 1 Shape Position ontact Part No. IP40 IP6 SPDT AS6M-2Y1 AS6M-2Y1P DPDT AS6M-2Y2 AS6M-2Y2P Spring return from SPDT AS6M-21Y1 AS6M-21Y1P right to left DPDT AS6M-21Y2 AS6M-21Y2P DPDT AS6M-3Y2 AS6M-3Y2P ound AS6M- Y AS6Q- Y ectangular AS6H- Y Bezel: black 90 2-position 4 3-position 90 2-position 4 3-position 90 2-position 4 3-position Terminal Width t 2. 3 Spring return from right to center DPDT AS6M-31Y2 AS6M-31Y2P Spring return from left to center DPDT AS6M-32Y2 AS6M-32Y2P Spring return two-way DPDT AS6M-33Y2 AS6M-33Y2P SPDT AS6Q-2Y1 AS6Q-2Y1P DPDT AS6Q-2Y2 AS6Q-2Y2P Spring return from SPDT AS6Q-21Y1 AS6Q-21Y1P right to left DPDT AS6Q-21Y2 AS6Q-21Y2P DPDT AS6Q-3Y2 AS6Q-3Y2P Spring return from right to center DPDT AS6Q-31Y2 AS6Q-31Y2P Spring return from left to center DPDT AS6Q-32Y2 AS6Q-32Y2P Spring return two-way DPDT AS6Q-33Y2 AS6Q-33Y2P SPDT AS6H-2Y1 AS6H-2Y1P DPDT AS6H-2Y2 AS6H-2Y2P Spring return from SPDT AS6H-21Y1 AS6H-21Y1P right to left DPDT AS6H-21Y2 AS6H-21Y2P DPDT AS6H-3Y2 AS6H-3Y2P Spring return from right to center DPDT AS6H-31Y2 AS6H-31Y2P Spring return from left to center DPDT AS6H-32Y2 AS6H-32Y2P Spring return two-way DPDT AS6H-33Y2 AS6H-33Y2P Knob: black ubber Gasket Anti-rotation ing ocking ing Panel Thickness 0. to 6 ectangular ontact Operation Position Operation eft enter ight 90 2-position 4 3-position Spring return from right Spring return from right Spring return from left Two-way return NO N eft ight ontact ontact NO N NO N eft ight ontact ontact NO N NO N SPDT DPDT DPDT eft ight ontact ontact NO N NO N ound NO N eft ight ontact ontact NO N NO N eft ight ontact ontact NO N NO N ø c18 Terminal Arrangement (bottom view) (Selector Switch) Mounting Hole ayout ound/ ø ectangular ø N1 N2 NO1 NO2 18 min. 18 min. 1 2 SPDT has N1, NO1, and 1 only. 18 min. Note: Determine mounting centers to ensure easy operation. 24 min. All dimensions in mm. 10

11 A6 Series Key Selector Switches ø16 Key Selector Switches ound AS6M Shape Position Operation 90 2-position Spring return from right A B B A Key etained at ontact IP40 Part No. Package Quantity: 1 IP6 SPDT AS6M-2K 1A AS6M-2K 1PA DPDT AS6M-2K 2A AS6M-2K 2PA SPDT AS6M-2K 1B AS6M-2K 1PB DPDT AS6M-2K 2B AS6M-2K 2PB SPDT AS6M-2K 1 AS6M-2K 1P DPDT AS6M-2K 2 AS6M-2K 2P SPDT AS6M-21K 1B AS6M-21K 1PB DPDT AS6M-21K 2B AS6M-21K 2PB DPDT AS6M-3K 2A AS6M-3K 2PA B DPDT AS6M-3K 2B AS6M-3K 2PB DPDT AS6M-3K 2 AS6M-3K 2P D DPDT AS6M-3K 2D AS6M-3K 2PD Disc tumbler key E DPDT AS6M-3K 2E AS6M-3K 2PE G DPDT AS6M-3K 2G AS6M-3K 2PG 4 3-position H B DPDT DPDT AS6M-3K 2H AS6M-31K 2B AS6M-3K 2PH AS6M-31K 2PB Wave key Spring return from right D DPDT AS6M-31K 2D AS6M-31K 2PD G DPDT AS6M-31K 2G AS6M-31K 2PG DPDT AS6M-32K 2 AS6M-32K 2P Spring return from left D DPDT AS6M-32K 2D AS6M-32K 2PD H DPDT AS6M-32K 2H AS6M-32K 2PH Spring return two-way D DPDT AS6M-33K 2D AS6M-33K 2PD Specify the key code in place of in the Part No.: T (disc tumbler key), S (wave key) For contact operation, see page 14. Key is retained at positions and removable at positions. Two keys are supplied. The front of key cylinder is made of metal. For disc tumbler key, only one type of key is available. For wave key, besides the standard key (key number 0H), six other keys are also available. To order other keys, specify the key number as shown below: Example: AS6M-2KS1PA-1H (blank): Standard key (0H) 1H to 2H: eversible key 3H to 6H: Non-reversible key Note: Key number is indicated on the key cylinder. Standard keys do not have a key number indication. 11

12 ø16 A6 Series Key Selector Switches Key Selector Switches AS6Q Shape Position Operation 90 2-position Spring return from right Package Quantity: 1 Key etained Part No. ontact at IP40 IP6 SPDT AS6Q-2K 1A AS6Q-2K 1PA A DPDT AS6Q-2K 2A AS6Q-2K 2PA SPDT AS6Q-2K 1B AS6Q-2K 1PB B DPDT AS6Q-2K 2B AS6Q-2K 2PB SPDT AS6Q-2K 1 AS6Q-2K 1P DPDT AS6Q-2K 2 AS6Q-2K 2P SPDT AS6Q-21K 1B AS6Q-21K 1PB B DPDT AS6Q-21K 2B AS6Q-21K 2PB A DPDT AS6Q-3K 2A AS6Q-3K 2PA B DPDT AS6Q-3K 2B AS6Q-3K 2PB DPDT AS6Q-3K 2 AS6Q-3K 2P D DPDT AS6Q-3K 2D AS6Q-3K 2PD Disc tumbler key E DPDT AS6Q-3K 2E AS6Q-3K 2PE G DPDT AS6Q-3K 2G AS6Q-3K 2PG 4 3-position H B DPDT AS6Q-3K 2H AS6Q-3K 2PH DPDT AS6Q-31K 2B AS6Q-31K 2PB Wave key Spring return from right D DPDT AS6Q-31K 2D AS6Q-31K 2PD G DPDT AS6Q-31K 2G AS6Q-31K 2PG DPDT AS6Q-32K 2 AS6Q-32K 2P Spring return from left D DPDT AS6Q-32K 2D AS6Q-32K 2PD H DPDT AS6Q-32K 2H AS6Q-32K 2PH Spring return two-way D DPDT AS6Q-33K 2D AS6Q-33K 2PD Specify the key code in place of in the Part No.: T (disc tumbler key), S (wave key) For contact operation, see page 14. Key is retained at positions and removable at positions. Two keys are supplied. The front of key cylinder is made of metal. For disc tumbler key, only one type of key is available. For wave key, besides the standard key (key number 0H), six other keys are also available. To order other keys, specify the key number as shown below: Example: AS6M-2KS1PA-1H (blank): Standard key (0H) 1H to 2H: eversible key 3H to 6H: Non-reversible key Note: Key number is indicated on the key cylinder. Standard keys do not have a key number indication. 12

13 A6 Series Key Selector Switches ø16 Key Selector Switches ectangular AS6H Shape Position Operation 90 2-position Spring return from right Package Quantity: 1 Key etained Part No. ontact at IP40 IP6 SPDT AS6H-2K 1A AS6H-2K 1PA A DPDT AS6H-2K 2A AS6H-2K 2PA SPDT AS6H-2K 1B AS6H-2K 1PB B DPDT AS6H-2K 2B AS6H-2K 2PB SPDT AS6H-2K 1 AS6H-2K 1P DPDT AS6H-2K 2 AS6H-2K 2P SPDT AS6H-21K 1B AS6H-21K 1PB B DPDT AS6H-21K 2B AS6H-21K 2PB A DPDT AS6H-3K 2A AS6H-3K 2PA B DPDT AS6H-3K 2B AS6H-3K 2PB DPDT AS6H-3K 2 AS6H-3K 2P D DPDT AS6H-3K 2D AS6H-3K 2PD Disc tumbler key E DPDT AS6H-3K 2E AS6H-3K 2PE G DPDT AS6H-3K 2G AS6H-3K 2PG 4 3-position H B DPDT AS6H-3K 2H AS6H-3K 2PH DPDT AS6H-31K 2B AS6H-31K 2PB Wave key Spring return from right D DPDT AS6H-31K 2D AS6H-31K 2PD G DPDT AS6H-31K 2G AS6H-31K 2PG DPDT AS6H-32K 2 AS6H-32K 2P Spring return from left D DPDT AS6H-32K 2D AS6H-32K 2PD H DPDT AS6H-32K 2H AS6H-32K 2PH Spring return two-way D DPDT AS6H-33K 2D AS6H-33K 2PD Specify the key code in place of in the Part No.: T (disc tumbler key), S (wave key) For contact operation, see page 14. Key is retained at positions and removable at positions. Two keys are supplied. The front of key cylinder is made of metal. For disc tumbler key, only one type of key is available. For wave key, besides the standard key (key number 0H), six other keys are also available. To order other keys, specify the key number as shown below: Example: AS6M-2KS1PA-1H (blank): Standard key (0H) 1H to 2H: eversible key 3H to 6H: Non-reversible key Note: Key number is indicated on the key cylinder. Standard keys do not have a key number indication. 13

14 ø16 A6 Series Key Selector Switches ontact Operation Operator Position & ontact Operation (Top View) Positions ontact eft enter ight NO N NO N SPDT 90 2-position Spring return from right DPDT eft ight ontact ontact NO N NO N eft ight ontact ontact NO N NO N 4 3-position Dimensions Disc Tumbler Key Spring return from right ight ontact 3 2. Spring return from left eft ontact ubber Gasket Anti-rotation ing Terminal Width t ocking ing 2. 3 TOP Spring return two-way DPDT Panel Thickness 0. to 6 eft ight ontact ontact NO N NO N ound eft ight ontact ontact NO N NO N eft ight ontact ontact NO N NO N ectangular N NO ø Wave Key Gasket ocking ing Panel thickness 0. to TOP Anti-rotation ing ound/ Terminal Width t ound ectangular N N NO NO 18 SPDT ectangular DPDT Key No.: 0H to 2H ø N N NO NO 18 SPDT DPDT Key No.: 3H to 6H ø Terminal Arrangement (bottom view) (Key Selector Switch) Mounting Hole ayout ound/ ectangular N1 N2 ø ø NO1 1 NO min. 18 min. Note: Determine mounting centers to ensure easy operation. SPDT has N1, NO1, and 1 only. 18 min. 24 min. All dimensions in mm. 14

15 A6 Series Accessories ø16 Accessories ocking ing Wrench Shape Material Part No. 60 ø18 Metal (nickel-plated brass) Ordering No. Package Quantity MT-001 MT emarks Used to tighten the locking ring when installing A6 series into a panel. amp Holder Tool ens emoval Tool Switch Guard [emains open} For pushbuttons, illuminated pushbuttons [Spring return] For pushbuttons, illuminated pushbuttons Dust over Terminal over Socket ø10 Mounting Hole Plug For round/ square units (110, 180 ) For rectangular units (remains 110, 180 ) For round/ square units (180 ) For rectangular units (180 ) Spring eturn 180 ubber O-77 O-77 1 Stainless Steel Guard (polyacetal) over (polyarylate) See page 16 for dimensions. MT-101 MT B9Z-K2 B9Z-K2 1 B9Z-K3P B9Z-K3P 1 A-K6S A-K6S 1 A-K6SP A-K6SP 1 A-KH6S A-KH6S 1 A-KH6SP A-KH6SP 1 Used to install and remove the ED lamps. Used to install and remove lenses and buttons. Degree of protection: IP40 Used to protect pushbuttons from inadvertent operation. Degree of protection: IP6 Used to protect pushbuttons from inadvertent operation. Degree of protection: IP40 Used to protect pushbuttons from inadvertent operation. Degree of protection: IP6 (when used with IP6 control units) Used to protect pushbuttons from inadvertent operation. Degree of protection: IP40 Used to protect pushbuttons from inadvertent operation. Degree of protection: IP6 (when used with IP6 control units) Used to protect pushbuttons from inadvertent operation. For round units For square units Translucent cover: elastomer A-D6 A-DQ6 A-D6 A-DQ6 1 1 When mounting the units with the dust covers installed, refer to mounting hole layout on page 17. Black part: Operating temperature: 10 to For rectan gular polypropylene A-DH6 A-DH6 1 + units Solder Terminal P Board Terminal ubber ø9 Polyamide (white) See page 17 for dimen sions. See page 17 for dimen sions. Nitryl rubber (black) A-V6 A-V6PN10 10 A-6 A-6 1 A-6V A-6V 1 A-B6 A-B6PN0 When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. Terminal cover is not attached and must be ordered separately. Plugs on the rear of the A series. Degree of protection: IP6 ø18 ø Mounting Hole 0 ø16.2 Mounting Hole Plug Metal Plug: metal (diecast) ocking ring: polyacetal Gasket: nitrile A-BM6 A-BM6 1 Degree of protection: IP6 Tightening torque: 0.1 to 0.29 N m ø17.8 Gasket Mounting Hole 0 ø16.2 ocking ing Panel Thickness 0. to 6 All dimensions in mm. 1

16 ø16 A6 Series Accessories Dimensions Switch Guard [emains open] For round/square units (Degree of protection: IP40) B9Z-K2 For rectangular units (Degree of protection: IP6) B9Z-K3P Panel Thickness 0. to Panel Thickness 0. to ubber Gasket 18 ubber Gasket [Spring return] For round/square units (Degree of protection: IP40) A-K6S Panel Thickness 0. to For rectangular units (Degree of protection: IP40) A-KH6S Panel Thickness 0. to 34 ubber Gasket ubber Gasket For round/square units (Degree of protection: IP6) A-K6SP 13. For rectangular units (Degree of protection: IP6) A-KH6SP Panel Thickness 0. to 34 Panel Thickness 0. to 34 ubber Gasket ubber Gasket Waterproof Gasket for Switch Guard Waterproof Gasket for Switch Guard

17 A6 Series Accessories ø16 Socket 33. TOP 2. 3 Terminal t Holes N1 N2 NO1 NO Solder Terminal (A-6) 6 6 P Board Terminal (A-6V) P Board Mounting Hole ayout (Bottom View) amp Terminal (+) 1 2 amp Terminal ( ) Terminal Arrangement (Bottom View) Terminal over ø16.8 Note: When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. Dust over Mounting Hole enters For ound Units (A-D6) ø24 For Units (A-DQ6) c 24 For ectangular Units (A-DH6) 30 ound/ Units ø ectangular Units ø min min. 24 Waterproof Gasket for Dust over Waterproof Gasket for Dust over Waterproof Gasket for Dust over 24 min. 30 min. arge ens and arge Button ubber Gasket Anti-rotation ing Terminal Width t 2. 3 ocking ing Panel Thickness 0. to 6 ectangular ound ø A6Q-K2-H➁ AB6Q-BK2-H➁ A6Q-K2-Q➁ AB6Q-BK2-Q➁ A6Q-K2-M➁ AB6Q-BK2-M➁ All dimensions in mm. 17

18 ø16 A6 Series Accessories Grip Style Enabling Switch Housing The following A6 series switches can be installed on the HE9Z- GSH1 grip style enabling switch housing to be used as handheld switches. AB6M pushbutton (IP6) AS6M selector switch (IP6) AS6M key selector switch (IP6) (illuminated pushbutton and pilot light cannot be installed) Part No. Ordering No. Package Quantity HE9Z-GSH1 HE9Z-GSH1 1 Specifications Applicable able onduit Port Size Weight (approx.) Outside diameter ø4. to 10 mm M16 (cable gland is supplied with the grip style enabling switch housing) 6g (grip style enabling switch housing only) The above specifications are for the grip style enabling switch housing only. Make sure to check the specifications of switches also. For the detailed specifications of grip style enabling switch housing, A6 series switches, and HEB enabling switch, see their catalogs. Notes: The HE9Z-GSH1 grip style enabling switch housing does not include the A6 series switche or HEB enabling switch, and they must be ordered separately. The switches must be installed and wired to the HE9Z- GSH1 grip style enabling switch housing by the user. For infor mation on wiring, see the instruction sheet supplied with the HE9Z-GSH1. Dimensions HE9Z-GSH1 HEB Enabling Switch (ordered separately) (78) able Gland Part No. SKINTOP BS-M16 1. (APP) HE9Z-GSH1 + HEB onstruction Head Housing able Gland ocking ing HEB Enabling Switch (not supplied with the grip style enabling switch housing) Anti-rotation ring is not required when installing the HEB enabling switch on the HE9Z-GSH1 grip style enabling switch housing. Use the locking ring only. Mounting Bracket Part No: HE9Z-GH ø.3 (For M mounting screws) Plastic oating Material: SUS304 Thickness: 3.0 mm All dimensions in mm. 18

19 A6 Series Maintenance Parts ø16 Maintenance Parts ens Button Marking Plate arge ens Unit ocking ing Shape Specification Part No. Ordering No. ound A6M-➁ A6M-➁PN0 Polyarylate A6Q-➁ A6Q-➁PN0 ectangular A6H-➁ A6H-➁PN0 Package Quantity emarks Specify a color code in place of ➁ in the Part No. A (amber), (clear), G (green) (red), S (blue), Y (yellow) Use a (clear) lens for W (white) and JW (pure white) illumination. ound AB6M-B➀ AB6M-B➀PN0 Specify a color code in place of ➀ in the Part No. Polyarylate AB6Q-B➀ AB6Q-B➀PN0 B (black), G (green), (red) ectangular S (blue), W (white), Y (yellow) AB6H-B➀ AB6H-B➀PN0 White A6M-W A6M-WPN0 ound Black A6M-B A6M-BPN0 ectangular ound (installed on round units) (installed on square units) ectangular (installed on square units) Acrylic White A6Q-W A6Q-WPN0 Black A6Q-B A6Q-BPN0 White A6H-W A6H-WPN0 Black A6H-B A6H-BPN0 Translucent color lens A6M-K2-M➁ A6M-K2-M➁ Opaque button AB6M-BK2-M➁ AB6M-BK2-M➁ Translucent color lens A6Q-K2-Q➁ A6Q-K2-Q➁ Opaque button AB6Q-BK2-Q➁ AB6Q-BK2-Q➁ Translucent color lens A6Q-K2-H➁ A6Q-K2-H➁ Opaque button AB6Q-BK2-H➁ AB6Q-BK2-H➁ 1 Specify a color code in place of ➁ in the Part No. Degree of protection: IP6 ➁ olor ode Translucent Opaque Button olor ens A (amber) G (green) (red) S (blue) W (white) Y (yellow) B (black) G (green) (red) S (blue) W (white) Y (yellow) See page 17 for dimensions. Polyacetal HA9Z-N HA9Z-NPN10 Black Anti-rotation ing 10 Stainless Steel B9Z-P1 B9Z-P1PN10 Spare key Key selector (disc tumbler key) Brass with nickel plating AS6-SK-132 AS6-SK-132PN02 2 Thickness 1.8 mm Spare Key eversible Key selector (wave key) Diecast zinc alloy (nickelplated) A9Z-SK- A9Z-SK- PN02 2 Specify a key number in place of in the Part No. 0H: Standard key (reversible) 1H to 2H: eversible key 3H to 6H: Non-reversible key Non-reversible Gasket ubber AP6M-WM AP6M-WMPN

20 ø16 A6 Series Maintenance Parts ED amps Dimensions Voltage Electrode Operating Volt age V D ±% 6V D ±% 12V A/ D ±10% 24V A/ D ±10% A 7 ma (G, S, JW) 8 ma (A,, W) urrent Draw D 8 ma ATD-➁ ma (G, S, JW) 6 ma (A,, W) Part No. Ordering No. ➁ Illumination olor ode ATD-6➁ 9 ma 8 ma ATD-1➁ 9 ma 8 ma ATD-2➁ Package Quantity ATD-➁ 1 ATD-➁PN10 ATD-6➁ Specify a color code in place of ➁ in the Ordering No ATD-6➁PN10 10 A: amber ATD-1➁ 1 JW: pure white ATD-1➁PN10 : red 10 ATD-2➁ S: blue 1 ATD-2➁PN10 10 Base Exclusive for A6 series Use a pure white (JW) ED lamp for yellow illumination Safety Precautions Turn off the power to A series before starting installation, removal, wiring, maintenance, and inspection of the units. Failure to turn power off may cause electrical shocks or fire hazard. To avoid a burn on your hand, use the lamp holder tool when replacing lamps. For wiring, use wires of a proper size to meet the voltage and current requirements. Failure to tighten terminal screws may cause overheating and create a fire hazard. Operating Instructions eplacement of ens and Marking Plate emoval emove the lens assembly (color lens, marking plate, lens holder, and spring) by holding the color lens recesses with the ens emoval Tool (MT-101) and pulling it out. emove the marking plate by disengaging the latches between the color lens and lens holder. The marking plate must be engraved on the front side as shown at right. When using a color film, insert it between the color lens and marking plate. Installation Place the marking plate on olor ens Marking Plate ens Holder the lens holder in the correct direction, and press the color lens onto the lens holder to engage the latches. Put the spring on the lens holder and insert the lens holder into the housing in the correct direction. Marking For A series illuminated pushbuttons, legends and symbols can be engraved on the built-in marking plates, or printed film can be inserted under the lens for labelling purposes. Marking Plate & Engraving Area Built-in Marking Plate and Engraving Area ø ound ectangular Engraving Area 12.0 Grooves 0.8 Fitting Grooves Engraving Surface Engraving Area c Engraving Area 18.0 Engraving must be made on the engraving area within 0.mm deep. The marking plate is made of white acrylic resin. eplacing the ED amp emoval Use the lamp holder tool (O-77) to remove lamps. Do not use pliers. Installation Use the lamp holder tool (O-77) to install lamps. Note the correct side of the tool for removal or installation. For installing lamps For removing lamps ø10 Panel Mounting O-77 ø9 All dimensions in mm. When mounting the units into a panel, use the optional locking ring wrench (MT-001) to tighten the locking ring. Do not use pliers. Tightening torque must not exceed 0.88 N m. Excessive tightening will damage the locking ring. Wiring Solder the terminal at 30 within 3 seconds using a 60W soldering iron. Sn-Ag-u is recommended when using lead-free solder. When soldering, do not touch the unit with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. Use a non-corrosive rosin flux. Installing the Socket Install the socket on the unit with the TOP markings on the unit and the socket placed in the same direction. Applicable Marking Film (not supplied) ø c Thickness = 0.1 mm 1 film ecommended film material: polyester 20

21 A6 Series Operating Instructions ø16 Switch Guard IP6 (IE 6029) switch guards must be used with IP6 (IE 6029) units only. Even if IP6 type switch guards are installed, enclosed type (IP40) units are not made waterproof. Switch Guard Item IP6 (IE 6029) IP40 (IE 6029) IP6 IP6 IP40 Switch IP40 IP40 IP40 Opening/closing the Switch Guard (B9Z-K2, B9Z-K3P) When opening/closing the switch guard while the switch guard is not installed on a panel, make sure to hold the hinge. Holding the base might result in damage. Also do not apply force on the guard in other than open/close directions, otherwise the hinge may be damaged. Hinge Base Operating Voltage of ED amps The operating voltage of V D is measured at complete D. Other Notes lose Proximity Mounting When mounting pilot lights or illuminated pushbuttons collectively or lighting them continuously, heat may cause the ambient temperature to rise above the rated operating temperature. When the mounting panel is not made of metal or when the units are mounted in an enclosed panel, provide for ventilation or lower the operating voltage. eplacement of Buttons (Illuminated/Non-illuminated) Do not replace buttons of maintained action units while the button is in the locked position. eplacing the button in the locked position may damage the internal mechanism. Be sure to release the button before replacing. Operating and Storage Environment 1. Make sure that the operating/storage temperature and humidity are within the ratings. 2. Do not use enclosed type units in an environment subject to oil, water or dust accumulation. In such an area, use the waterproof/ oiltight units (IP6). Microswitch ontacts Do not connect NO and N contacts of a microswitch to different voltages or different power sources to prevent a dead short-circuit. IP6 Units IP6 units are evaluated by conventional cutting and cooling oils, and can not be used with some special oils. ontact IDE for resistance against specific oils. Selector Switches with Key Observe the following instructions to prevent malfunction or damage. Insert the key to the bottom of the key hole. Do not remove the key from any key retained position. Besides the standard key (key number 0H), six other key numbers are available. Use a key of the matching number with the key cylinder. The standard key does not have a key number indication. Keys are available in two types. Key numbers 0H (standard), 1H, and 2H are reversible keys which can be inserted in two ways. Key numbers 3H, 4H, H, and 6H are non-reversible keys. Make sure of correct insertion direction. 21

22 ø12 A2 Series Switches and Pilot ights Short 22-mm-long body miniature switches and pilot lights with bright ED illumination face and snap-action switching. Degree of protection: IP40 and IP6 (IE 6029) All series have terminals on the same plane. U recognized, SA certified U08 Applicable Standards Mark File No. or Organization U ecognition File No. E996 SA 22.2 No.14 SA File No GB No (except for pilot lights) ontact atings (ontact Block) ated Insulation Voltage 20V ated Thermal urrent 3A Operating Voltage (A/D) 24V 110V 220V A 0/60 Hz esistive oad 1.0A 0.A Inductive oad 0.7A 0.A D esistive oad 1.0A 0.2A Inductive oad 0.7A 0.1A ontact Material Silver Minimum applicable load: V A/D, 3 ma (applicable range may vary with operating conditions and load types) Weight Weight (approx.) A2M-M11: 4g A2M-P1: 4g AB2M-M1: 4g Specifications Operating Temperature 2 to + (no freezing) Storage Temperature 30 to +80 (no freezing) Operating Humidity 4 to 8% H (no condensation) ontact esistance 0 mω maximum (initial value) Insulation esistance 100 MΩ minimum (00V D megger) Between live and dead metal parts: 2,000V A, 1 minute Between terminals of different poles: 2,000V A, 1 minute Switch Unit Dielectric Between terminals of the same pole: Strength 1,000V A, 1 minute Between contact and lamp terminals: 1,00V A, 1 minute Illumination Between live part and ground: Unit 2,000V A, 1 minute Damage limits, Operating extremes: Vibration esistance to Hz, amplitude 0.7 mm Damage limits: 00 m/s Shock esistance 2 (0G) Operating extremes: 200 m/s 2 (20G) Mechanical Durability : 200,000 operations (minimum operations) : 100,000 operations : 100,000 operations Electrical Durability : 0,000 operations (minimum operations) (Switching frequency 1200 operations/h) Degree of Protection IP40, IP6 (IE 6029) ED amp atings (AD-S) Built-in ED Part No. AD-SA AD-SG AD-S AD-SY amp Base Exclusive for A series Forward urrent (If) 20 ma Forward Voltage (Vf) (nominal) 2.2V 2.1V 1.7V 2.2V everse Voltage (Vr) 4V Illumination olor A G Y ED amp olor Amber lear Yellow Diffused ed lear Yellow lear Applicable ens olor Amber Green ed Yellow and White Base Plastic olor ed ED amp ife (reference value) Approx. 0,000 hours (The illuminance reduces to 0% of the initial intensity when used on complete D.) Operating Voltage & External urrent-limiting esistor (recommended value) (Note) V D: 10Ω, 1/2W 6V D: 200Ω, 1/2W 12V D: 10Ω, 1W 24V D: 1.1 kω, 1W Internal ircuit (+) ( ) Note: When ED lamps are used on voltages other than the above, external resistor value is determined by the following formula: = (operating voltage Vf) / If ED lamps do not have a current-limiting resistor, and external resistors of recommended values (+) for each voltage must be provided. onnect a current-limiting resistor in series, otherwise ED urrent amp lamps will be damaged. Because no protection diode is contained, ensure the correct polarity is imiting Terminal (+) esistor observed. ( ) amp Terminal ( ) 22

23 A2 Series Illuminated Pushbuttons and Pilot ights ø12 Illuminated Pushbuttons & Pilot ights ound A2M Shape Operation ontact IP40 Part No. IP6 SPDT A2M-M11➁ A2M-M11P➁ DPDT A2M-M21➁ A2M-M21P➁ ➁ ens olor ode Package Quantity: 1 ED amp Part No., ated urrent (External esistor ecommended Value) (except for pilot lights) SPDT A2M-A11➁ A2M-A11P➁ DPDT A2M-A21➁ A2M-A21P➁ Pilot ight A2M-P1➁ A2M-P1P➁ A2Q SPDT A2Q-M11➁ A2Q-M11P➁ DPDT A2Q-M21➁ A2Q-M21P➁ Specify a color code in place of ➁ in the Part No. A: AD-SA G: AD-SG : AD-S W/Y: AD-SY (except for pilot lights) SPDT A2Q-A11➁ A2Q-A11P➁ DPDT A2Q-A21➁ A2Q-A21P➁ Pilot ight A2Q-P1➁ A2Q-P1P➁ A: amber : red ated urrent: 20 ma V D: 10Ω, 1/2W 6V D: 200Ω, 1/2W 12V D: 10Ω, 1W 24V D: 1.1 kω, 1W ectangular A2H SPDT A2H-M11➁ A2H-M11P➁ DPDT A2H-M21➁ A2H-M21P➁ (except for pilot lights) SPDT A2H-A11➁ A2H-A11P➁ DPDT A2H-A21➁ A2H-A21P➁ Pilot ight A2H-P1➁ A2H-P1P➁ ED lamps do not have a current-limiting resistor. onnect a current-limiting resistor in series, otherwise ED lamps will be damaged. External current-limiting resistor is not necessary when an optional socket with built-in resistor is used (see page 2). AP2M series pilot lights (round bezel only) with built-in current-limiting resistors are also available. Pilot lights are not certifed. Dimensions 2.8 Panel Thickness 0. to 6 ubber Gasket ocking ing Terminal Width t ectangular (+) urrent imiting esistor amp Terminal (+) ( ) amp Terminal ( ) ound ø c14 ø14 Terminal Arrangement amp Terminal (+) Mounting Hole ayout ound/ Units ø12 0 ectangular Units ø12 0 N1N2 NO1 1 NO2 2 SPDT has N1, NO1, and 1 only. 14 min. 14 min. Note: Determine mounting centers to ensure easy operation. amp Terminal ( ) 14 min. 18 min. All dimensions in mm. 23

24 ø12 A2 Series Pushbuttons Pushbuttons ound AB2M Package Quantity: 1 Part No. Shape Button Style Operation ontact olor ode ➀➁ IP40 IP6 SPDT AB2M-M1➀ AB2M-M1P➀ B: black DPDT AB2M-M2➀ AB2M-M2P➀ : red Button SPDT AB2M-A1➀ AB2M-A1P➀ S: blue DPDT AB2M-A2➀ AB2M-A2P➀ AB2Q ens Button SPDT AB2M-M1➁ AB2M-M1P➁ A: amber DPDT AB2M-M2➁ AB2M-M2P➁ : red SPDT AB2M-A1➁ AB2M-A1P➁ DPDT AB2M-A2➁ AB2M-A2P➁ SPDT AB2Q-M1➀ AB2Q-M1P➀ B: black DPDT AB2Q-M2➀ AB2Q-M2P➀ : red SPDT AB2Q-A1➀ AB2Q-A1P➀ S: blue DPDT AB2Q-A2➀ AB2Q-A2P➀ ectangular AB2H ens Button SPDT AB2Q-M1➁ AB2Q-M1P➁ A: amber DPDT AB2Q-M2➁ AB2Q-M2P➁ : red SPDT AB2Q-A1➁ AB2Q-A1P➁ DPDT AB2Q-A2➁ AB2Q-A2P➁ SPDT AB2H-M1➀ AB2H-M1P➀ B: black DPDT AB2H-M2➀ AB2H-M2P➀ : red SPDT AB2H-A1➀ AB2H-A1P➀ S: blue DPDT AB2H-A2➀ AB2H-A2P➀ ens Specify a color code in place of ➀ or ➁ in the Part No. Dimensions 2.8 Panel Thickness 0. to 6 ubber Gasket ocking ing ectangular SPDT AB2H-M1➁ AB2H-M1P➁ A: amber DPDT AB2H-M2➁ AB2H-M2P➁ : red SPDT AB2H-A1➁ AB2H-A1P➁ DPDT AB2H-A2➁ AB2H-A2P➁ ound c14 ø14 Terminal Arrangement N1N2 Mounting Hole ayout ound/ Units ø12 0 ectangular Units ø12 0 NO1 1 NO min. 14 min. SPDT has N1, NO1, and 1 only. 14 min. 18 min. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. 24

25 A2 Series Accessories ø12 Accessories ocking ing Wrench ens emoval Tool Shape Material Part No. 60 ø14 Metal (nickel-plated brass) Ordering Part No. Package Quantity MT-002 MT emarks Used to tighten the locking ring when installing the A2 series into a panel. Stainless Steel MT-101 MT Used to remove lens and button. 60 amp Holder Tool 70 Switch Guard Socket Socket with Built-in esistor Terminal over Dust over Mounting Hole Plug ubber O-66 O-66 1 Used to remove and install ED lamps. 90 open For round/ square unit For rectangular unit A-K2 A-K2 1 A-KH2 A-KH2 1 Solder Terminal A-2 A-2 1 P Board Terminal A-2V A-2V 1 Solder Terminal P Board Terminal V D A-21 A-21 1 Degree of protection: IP40 Used to protect pushbuttons from inadvertent operation. See page 26 for dimensions. Snaps on the rear of the A2 series. (see page 26 for dimensions) Socket Bottom olor Blue 6V D A-22 A-22 1 Green 12V D A-23 A-23 1 Yellow 24V D A-24 A-24 1 ed V D A-21V A-21V 1 Blue 6V D A-22V A-22V 1 Green 12V D A-23V A-23V 1 Yellow 24V D A-24V A-24V 1 ed Nylon A-V2 A-V2PN10 10 For round units A-D2 A-D2 1 For square units A-DQ2 A-DQ2 1 For rectangular units A-DH2 A-DH2 1 A current limiting resistor is contained, eliminating the need for external resistors. When using the socket with a built-in resistor, make sure that the continuous current is 1A maximum and the operating temperature is 2 to +40. In collective mounting, keep center-to center-spacing of 20 mm or more between adjacent units in consideration of built-in resistor heating. See page 26 for dimensions. When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. Terminal cover is not attached and must be ordered separately. When mounting the units with the dust covers installed, refer to mounting hole layout on page 26. Operating temperature: 10 to + Material Front part: Elastomer (transparent) ear part: Polypropylene (black) See page 26 for dimensions and mounting hole layout. Nitryl rubber (black) A-B2 A-B2PN0 Degree of protection: IP6 (remains 90 open) 2

26 ø12 A2 Series Accessories Dimensions Switch Guard For ound/ Units (A-K2) 14 Panel Thickness to For ectangular Units (A-KH2) 18 Panel Thickness to min. 12. ubber Gasket min. 12. ubber Gasket 1 min. 19 min. Socket (A-2, A-2V, A-2 ) Terminal t Terminal Arrangement amp Terminal (+) N1 N NO1 NO Solder Terminal (A-2) Solder Terminal with Built-in esistor (A-2 ) P Board Terminal (A-2V) P Board Terminal with Built-in esistor (A-2 V) Holes Panel ut-out Bottom View amp Terminal ( ) Holes Panel ut-out Bottom View Terminal over (A-V2) 17.3 ø12.8 Note: When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. 33. Dust over For ound Units (A-D2) For Units (A-DQ2) For ectangular Units (A-DH2) Mounting Hole enters (ound Units, Units) ø20 c ø min. 20 min. (ectangular Units) Waterproof Gasket for Dust over Waterproof Gasket for Dust over Waterproof Gasket for Dust over ø12 20 min. 24 min. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. 26

27 A2 Series Maintenance Parts ø12 Maintenance Parts Shape Specification Part No. Ordering Part No. Marking Plate ound A2M-W A2M-WPN0 Package Quantity olor ode ➀➁ ens Unit Button Unit ED amp urrent-limiting resistor is not contained ø4.0 All dimensions in mm. A2Q-W A2Q-WPN0 ectangular A2H-W A2H-WPN0 For IP40 units For IP6 illuminated pushbuttons For IP6 pilot lights For IP40 pushbuttons For IP6 pushbuttons Illumination color: amber Illumination color: green Illumination color: red Illumination color: yellow ound A2M-K1-➁ A2M-K1-➁PN02 A2Q-K1-➁ A2Q-K1-➁PN02 ectangular A2H-K1-➁ A2H-K1-➁PN02 ound A2M-K2-➁ A2M-K2-➁ A2Q-K2-➁ A2Q-K2-➁ ectangular A2H-K2-➁ A2H-K2-➁ ound A2M-K3-➁ A2M-K3-➁ A2Q-K3-➁ A2Q-K3-➁ ectangular A2H-K3-➁ A2H-K3-➁ ound AB2M-BK1-➀ AB2M-BK1-➀PN02 AB2Q-BK1-➀ AB2Q-BK1-➀PN02 ectangular AB2H-BK1-➀ AB2H-BK1-➀PN02 ound AB2M-BK2-➀ AB2M-BK2-➀ AB2Q-BK2-➀ AB2Q-BK2-➀ ectangular AB2H-BK2-➀ AB2H-BK2-➀ AD-SA AD-SG AD-S AD-SY AD-SA 1 AD-SAPN10 10 AD-SG 1 AD-SGPN10 10 AD-S 1 AD-SPN10 10 AD-SY 1 AD-SYPN10 10 White Specify a color code in place of ➁ in the Part No. A: amber : red Specify a color code in place of ➀ in the Part No. B: black : red S: blue ens color Amber Green ed White/ Yellow ED color: amber clear ED color: yellow diffused ED color: clear red ED color: yellow clear 27

28 ø12 A2 Series Operating Instructions Safety Precautions Turn off the power to A series before starting installation, removal, wiring, maintenance, and inspection of the units. Failure to turn power off may cause electrical shocks or fire hazard. To avoid burning your hand, use the lamp holder tool when replacing lamps. For wiring, use wires of a proper gauge to meet the voltage and current requirements. Failure to tighten terminal screws may cause overheating and create a fire hazard. Operating Instructions eplacement of ens and Marking Plate emoval emove the lens assembly (color lens, marking plate, lens holder, and spring) by holding the color lens recesses with the ens emoval Tool (MT-101) and pulling it out. emove the marking plate by disengaging the latches between the color lens and lens holder. The marking plate must be engraved on the front side as shown below. atches Installation Place the marking plate on the lens holder in the correct direction, and press the color lens onto the lens holder to engage the latches. Put the spring on the lens holder and insert the lens holder into the housing in the correct direction. Installing Non-illuminated Button Non-illuminated pushbuttons contain a marking plate like illuminated units. Be sure to install the marking plate when replacing the button. Marking For A series illuminated pushbuttons, legends and symbols can be engraved on the built-in marking plates, or printed film can be inserted under the lens. Marking Plate & Engraving Area ens ound ectangular Built-in Marking Plate ø9 0.8 Engraving Area olor ens Marking Plate Engraving Area 9 Size: ø10 Engraving must be made on the engraving area less than 0.mm deep. The marking plate is made of white acrylic resin. eplacing the ED amp 0.8 ens Holder Engraving Area emoval Use the lamp holder tool (O-66) to remove lamps. Do not use pliers. Installation Use the lamp holder tool (O-66) to install lamps. Note the correct side of the tool for removal or installation. 8 Size: 10 amp Holder Tool O-66 (ø8, ø10, ø12 series) Engraving Area 12 Size: 14 x 10 Panel Mounting When mounting the units onto a panel, use the optional locking ring wrench (MT-002) to tighten the locking ring. Do not use pliers. Tightening torque must not exceed 0.78 N m. Excessive tightening will damage the locking ring. Wiring Solder the terminal at 30 within 3 seconds using a 60W soldering iron. Sn-Ag-u is recommended when using lead-free solder. When soldering, do not touch the unit with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. Use non-corrosive rosin flux. Installing the Socket Install the socket on the unit with the TOP markings on the unit and the socket placed in the same direction. Operating Voltage of ED amps The operating voltage is measured at complete D. When using a pulsating voltage such as a full-wave rectification voltage, keep peak currents within the forward current If. Peak currents exceeding the If may shorten the ED lamp life. Other Notes lose Proximity Mounting When mounting pilot lights or illuminated pushbuttons collectively or lighting them continuously, heat may cause the ambient temperature to rise above the rated operating temperature. When the mounting panel is not made of metal or when the units are mounted in an enclosed panel, provide for ventilation or lower the operating voltage. eplacement of Buttons (Illuminated/Non-illuminated) Do not replace buttons of maintained action units while the button is in the locked position. eplacing the button in the locked position may damage the internal mechanism. Be sure to release the button before replacing. Operating and Storage Environment 1. Make sure that the operating/storage temperature and humidity are within the ratings. 2. Do not use enclosed units (IP40) in an environment subject to oil, water or dust accumulation. In such an area, use the waterproof/oiltight units (IP6). Microswitch ontacts Do not connect NO and N contacts of the microswitch to different voltages or different power sources to prevent a dead short-circuit. IP6 Units IP6 units are evaluated by conventional cutting and cooling oils, and can not be used with some special oils. ontact IDE for resistance against special oils. For removing lamps For installing lamps 28

29 ø10 A1 Series Switches and Pilot ights Short 22-mm-long body miniature switches and pilot lights with ED illumination face and snap-action switching. Bright and clear ED illumination. All series have terminals on the same plane. U recognized, SA certified U08 Applicable Standards Mark File No. or Organization U ecognition File No. E996 SA 22.2 No.14 SA File No GB No (except for pilot lights) ontact atings (ontact Block) ated Insulation Voltage 20V ated Thermal urrent 3A Operating Voltage (A/D) 24V 110V 220V A 0/60 Hz esistive oad 1.0A 0.A Inductive oad 0.7A 0.A D esistive oad 1.0A 0.2A Inductive oad 0.7A 0.1A ontact Material Silver Minimum applicable load: V A/D, 3 ma (applicable range may vary with operating conditions and load types) Weight Weight (approx.) A1M-M11: 3g A1M-P1: 3g AB1M-M1: 3g Specifications Operating Temperature 2 to + (no freezing) Storage Temperature 30 to +80 (no freezing) Operating Humidity 4 to 8% H (no condensation) ontact esistance 0 mω maximum (initial value) Insulation esistance 100 MΩ minimum (00V D megger) Between live and dead metal parts: 2,000V A, 1 minute Between terminals of different poles: 2,000V A, 1 minute Switch Unit Dielectric Between terminals of the same pole: Strength 1,000V A, 1 minute Between contact and lamp terminals: 1,00V A, 1 minute Illumination Between live part and ground: Unit 2,000V A, 1 minute Damage imits, Operating extremes: Vibration esistance to Hz, amplitude 0.7 mm Damage limits: 00 m/s Shock esistance 2 (0G) Operating extremes: 200 m/s 2 (20G) Mechanical Durability : 200,000 operations (minimum operations) : 100,000 operations : 100,000 operations Electrical Durability : 0,000 operations (minimum operations) (Switching frequency 1200 operations/h) Degree of Protection IP40 (IE 6029) ED amp atings (AD-S) Built-in ED Part No. AD-SA AD-SG AD-S AD-SY amp Base Exclusive for A series Forward urrent (If) 20 ma Forward Voltage (Vf) (nominal) 2.2V 2.1V 1.7V 2.2V everse Voltage (Vr) 4V Illumination olor A G Y ED amp olor Amber lear Yellow Diffused ed lear Yellow lear Applicable ens olor Amber Green ed Yellow and White Base Plastic olor ed ED amp ife (reference value) Approx. 0,000 hours (The illuminance reduces to 0% of the initial intensity when used on complete D.) Operating Voltage & External urrent-limiting esistor (recommended value) (Note) V D: 10Ω, 1/2W 6V D: 200Ω, 1/2W 12V D: 10Ω, 1W 24V D: 1.1 kω, 1W Internal ircuit (+) ( ) Note: When ED lamps are used on voltages other than the above, external resistor value is determined by the following formula: = (operating voltage Vf) / If ED lamps do not have a current-limiting resistor, and external resistors of recommended values for each voltage must be provided. onnect a current-limiting resistor in series, otherwise ED lamps will be damaged. Because no protection diode is contained, ensure the correct polarity is observed. (+) urrent imiting esistor amp Terminal (+) ( ) amp Terminal ( ) 29

30 ø10 A1 Series Illuminated Pushbuttons and Pilot ights Illuminated Pushbuttons & Pilot ights ound A1M Shape Operation ontact Part No. IP40 SPDT A1M-M11➁ ➁ ens olor ode Package Quantity: 1 ED amp Part No., ated urrent (External esistor ecommended Value) SPDT A1M-A11➁ (except for pilot lights) Pilot ight A1M-P1➁ A1Q ectangular A1H (except for pilot lights) SPDT A1Q-M11➁ SPDT A1Q-A11➁ Pilot ight A1Q-P1➁ SPDT A1H-M11➁ Specify a color code in place of ➁ in the Part No. A: amber : red A: AD-SA G: AD-SG : AD-S W/Y: AD-SY ated urrent: 20 ma V D: 10Ω, 1/2W 6V D: 200Ω, 1/2W 12V D: 10Ω, 1W 24V D: 1.1 kω, 1W SPDT A1H-A11➁ (except for pilot lights) Pilot ight A1H-P1➁ ED lamps do not have a current-limiting resistor. onnect a current-limiting resistor in series, otherwise ED lamps will be damaged. AP1M series pilot lights (round bezel only) with built-in current-limiting resistor are also available. Pilot lights are not certifed. Dimensions (+) ( ) Panel Thickness 0. to ocking ing Terminal Width t ectangular ound ø c12 ø Terminal Arrangement (bottom view) N Mounting Hole ayout ound/ Units ø10 0 ectangular Units ø10 0 amp Terminal (+) NO OM amp Terminal ( ) 12 min. 12 min. 12 min. 16 min. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. 30

31 A1 Series Pushbuttons ø10 Pushbuttons ound AB1M AB1Q ectangular AB1H Shape Button Style Operation ontact Button ens Button ens Button ens Part No. IP40 SPDT AB1M-M1➀ SPDT AB1M-A1➀ SPDT AB1M-M1➁ SPDT AB1M-A1➁ SPDT AB1Q-M1➀ SPDT AB1Q-A1➀ SPDT AB1Q-M1➁ SPDT AB1Q-A1➁ SPDT AB1H-M1➀ SPDT AB1H-A1➀ SPDT AB1H-M1➁ SPDT AB1H-A1➁ Package Quantity: 1 olor ode ➀➁ B black : red S: blue A: amber : red B black : red S: blue A: amber : red B black : red S: blue A: amber : red Specify a color code in place of ➀ or ➁ in the Part No. Dimensions Panel Thickness 0. to ocking ing Terminal Width t ectangular ound c12 ø Terminal Arrangement (bottom view) Mounting Hole ayout ound/ Units ectangular Units N ø10 0 ø10 0 NO OM 12 min. 12 min. 12 min. 16 min. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. 31

32 ø10 A1 Series Accessories Accessories ocking ing Wrench Shape Material Part No. Ordering No. Package Quantity emarks ø12 Metal (nickel-plated brass) MT-003 MT Used to tighten the locking ring when installing the A1 series into a panel. 60 ens emoval Tool Stainless Steel MT-101 MT Used to remove lens and button. 60 amp Holder Tool ubber O-66 O-66 1 Used to remove and install ED lamps. 70 Switch Guard 90 open For round/ square unit For rectangular unit A-K1 A-K1 1 A-KH1 A-KH1 1 Used to protect pushbuttons from inadvertent operation. See page 33 for dimensions. (remains 90 open) Socket Terminal over Mounting Hole Plug Solder Terminal A-1 A-1 1 P Board Terminal A-1V A-1V 1 Nylon A-V1 A-V1PN10 10 Snaps on the rear of the A1 series. (see page 33 for dimensions) When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. Terminal cover is not attached and must be ordered separately. Degree of protection: IP6 Nitryl rubber (black) A-B1 A-B1PN0 2 ø

33 A1 Series Accesories and Maintenance Parts ø10 Dimensions Switch Guard For ound/ Units (A-K1) 12 For ectangular Units (A-KH1) 16 Panel Thickness to min min min. 17 min. Socket (A-1, A-1V) Terminal t Terminal Arrangement N NO Holes amp Terminal (+) OM amp Terminal ( ) Solder Terminal (A-1) P Board Terminal (A-1V) (P Board Terminal Mounting Hole ayout) (Bottom View) Terminal over 17.3 ø10.8 Note: When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. 33. All dimensions in mm. Maintenance Parts Shape Part No. Ordering No. Marking Plate ound A1M-W A1M-WPN0 A1Q-W A1Q-WPN0 ectangular A1H-W A1H-WPN0 Package Quantity White olor ode ➀➁ ens Unit ound A1M-K1-➁ A1M-K1-➁PN02 Specify a color code in place of ➁ in the Part No. A1Q-K1-➁ A1Q-K1-➁PN02 A (amber), G (green), (red) ectangular A1H-K1-➁ A1H-K1-➁PN02 W (white), Y (yellow) 2 Button Unit ound AB1M-BK1-➀ AB1M-BK1-➀PN02 Specify a color code in place of ➀ in the Part No. AB1Q-BK1-➀ AB1Q-BK1-➀PN02 B (black), G (green), (red) ectangular AB1H-BK1-➀ AB1H-BK1-➀PN02 S (blue), W (white), Y (yellow) ED amp urrent-limiting resistor is not contained ø4.0 All dimensions in mm. Illumination color: amber Illumination color: green Illumination color: red Illumination color: yellow AD-SA AD-SG AD-S AD-SY AD-SA 1 AD-SAPN10 10 AD-SG 1 AD-SGPN10 10 AD-S 1 AD-SPN10 10 AD-SY 1 AD-SYPN10 10 ens color Amber Green ed White/ Yellow ED color: amber clear ED color: yellow diffused ED color: clear red ED color: yellow clear 33

34 ø10 A1 Series Operating Instructions Safety Precautions Turn off the power to A series before starting installation, removal, wiring, maintenance, and inspection of the units. Failure to turn power off may cause electrical shocks or fire hazard. To avoid burning your hand, use the lamp holder tool when replacing lamps. For wiring, use wires of a proper gauge to meet the voltage and current requirements. Failure to tighten terminal screws may cause overheating and create a fire hazard. Operating Instructions eplacement of ens and Marking Plate emoval emove the lens assembly (color lens, marking plate, lens holder, and spring) by holding the color lens recesses with the ens emoval Tool (MT-101) and pulling it out. emove the marking plate by disengaging the latches between the color lens and lens holder. The marking plate must be engraved on the front side as shown below. atches eplacing the ED amp emoval Use the lamp holder tool (O-66) to remove lamps. Do not use pliers. Installation Use the lamp holder tool (O-66) to install lamps. Note the correct side of the tool for removal or installation. amp Holder Tool O-66 (ø8, ø10, ø12 series) Note: Make sure that the spring is inserted in the correct direction. The base of spring must fit the groove in the holder. Installation Place the marking plate on the lens holder in the correct direction, and press the color lens onto the lens holder to engage the latches. Put the spring on the lens holder and insert the lens holder into the housing in the correct direction. Installing Non-illuminated Button Non-illuminated pushbuttons contain a marking plate like illuminated units. Be sure to install the marking plate when replacing the button. Marking For A series illuminated pushbuttons, legends and symbols can be engraved on the built-in marking plates, or printed film can be inserted under the lens. Marking Plate & Engraving Area ens ound ectangular Built-in Marking Plate ø Engraving Area olor lens Marking Plate Engraving Area 7. Size: ø Spring ens etaining Holder Groove Engraving Area 7. Size: 8. Spring Engraving must be made on the engraving area less than 0.mm deep. The marking plate is made of white acrylic resin Engraving Area 11. Size: 12. x 8. Panel Mounting When mounting the units into a panel, use the optional locking ring wrench (MT-003) to tighten the locking ring. Do not use pliers. Tightening torque must not exceed 0.29 N m. Excessive tightening will damage the locking ring. Wiring Solder the terminal at 30 within 3 seconds using a 60W soldering iron. Sn-Ag-u is recommended when using lead-free solder. When soldering, do not touch the unit with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. Use non-corrosive rosin flux. Installing the Socket Install the socket on the unit with the TOP markings on the unit and the socket placed in the same direction. Operating Voltage of ED amps The operating voltage is measured at complete D. When using a pulsating voltage such as a full-wave rectification voltage, keep peak currents within the forward current If. Peak currents exceeding the If may shorten the ED lamp life. Other Notes For removing lamps For installing lamps lose Proximity Mounting When mounting pilot lights or illuminated pushbuttons collectively or lighting them continuously, heat may cause the ambient temperature to rise above the rated operating temperature. When the mounting panel is not made of metal or when the units are mounted in an enclosed panel, provide for ventilation or lower the operating voltage. eplacement of Buttons (Illuminated/Non-illuminated) Do not replace buttons of maintained action units while the button is in the locked position. eplacing the button in the locked position may damage the internal mechanism. Be sure to release the button before replacing. Operating and Storage Environment 1. Make sure that the operating/storage temperature and humidity are within the ratings. 2. Do not use enclosed type units in an environment subject to oil, water or dust accumulation. Microswitch ontacts Do not connect NO and N contacts of the microswitch to different voltages or different power sources to prevent a dead short-circuit. 34

35 ø8 A8 Series Switches and Pilot ights Short 22-mm-long body miniature switches and pilot lights with ED illumination face and snap-action switching. Bright and clear ED illumination. All series have terminals on the same plane. U recognized, SA certified U08 Applicable Standards Mark File No. / Organization U ecognition File No. E996 SA 22.2 No.14 SA File No GB No (except for pilot lights) ontact atings (ontact Block) ated Insulation Voltage 20V ated Thermal urrent 3A Operating Voltage (A/D) 24V 110V 220V A 0/60 Hz esistive oad 1.0A 0.A Inductive oad 0.7A 0.A D esistive oad 1.0A 0.2A Inductive oad 0.7A 0.1A ontact Material Silver Minimum applicable load: V A/D, 3 ma (applicable range may vary with operating conditions and load types) Weight Weight (approx.) A8M-M11: 2g A8M-P1: 2g AB8M-M1: 2g ED amp atings (AD-S) Part No. AD-SA AD-SG AD-S AD-SY amp Base Exclusive for A series Forward urrent (If) 20 ma Forward Voltage (Vf) (nominal) 2.2V 2.1V 1.7V 2.2V everse Voltage (Vr) 4V Illumination olor A G Y ED amp olor Amber lear Yellow Diffused ed lear Yellow lear Applicable ens olor Amber Green ed Yellow and White Base Plastic olor ed ED amp ife (reference value) Approx. 0,000 hours (The illuminance reduces to 0% of the initial intensity when used on complete D.) Operating Voltage & External urrent-limiting esistor (recommended value) (Note) V D: 10Ω, 1/2W 6V D: 200Ω, 1/2W 12V D: 10Ω, 1W 24V D: 1.1 kω, 1W Specifications Internal ircuit (+) ( ) Operating Temperature 2 to + (no freezing) Storage Temperature 30 to +80 (no freezing) Operating Humidity 4 to 8% H (no condensation) ontact esistance 0 mω maximum (initial value) Insulation esistance 100 MΩ minimum (00V D megger) Between live and dead metal parts 2,000V A, 1 minute Between terminals of different poles: 2,000V A, 1 minute Switch Unit Dielectric Between terminals of the same pole: Strength 1,000V A, 1 minute Between contact and lamp terminals: 1,00V A, 1 minute Illumination Between live part and ground: Unit 2,000V A, 1 minute Damage imits, Operating extremes: Vibration esistance to Hz, amplitude 0.7 mm Damage limits: 00 m/s Shock esistance 2 (0G) Operating extremes: 200 m/s 2 (20G) Mechanical Durability : 200,000 operations (minimum operations) : 100,000 operations : 100,000 operations Electrical Durability : 0,000 operations (minimum operations) (Switching frequency 1200 operations/h) Degree of Protection IP40 (IE 6029) Note: When ED lamps are used on voltages other than the above, external resistor value is determined by the following formula: = (operating voltage Vf) / If ED lamps do not have a current-limiting resistor, and external resistors of recommended values or each voltage must be provided. onnect a current-limiting resistor in series, otherwise ED lamps will be damaged. Because no protection diode is contained, ensure the correct polarity is observed. (+) urrent imiting esistor amp Terminal (+) ( ) amp Terminal ( ) 3

36 ø8 A8 Series Illuminated Pushbuttons and Pilot ights Illuminated Pushbuttons & Pilot ights ound A8M Shape Operation ontact Part No. IP40 SPDT A8M-M11➁ ➁ ens olor ode Package Quantity: 1 ED amp Part No., ated urrent (External esistor ecommended Value) SPDT A8M-A11➁ (except for pilot lights) Pilot ight A8M-P1➁ A8Q SPDT A8Q-M11➁ Specify a color code in place of ➁ in the Part No. A: AD-SA G: AD-SG : AD-S W/Y: AD-SY (except for pilot lights) SPDT A8Q-A11➁ Pilot ight A8Q-P1➁ A: amber : red ated urrent: 20 ma V D: 10Ω, 1/2W 6V D: 200Ω, 1/2W 12V D: 10Ω, 1W 24V D: 1.1 kω, 1W ectangular A8H SPDT A8H-M11➁ SPDT A8H-A11➁ (except for pilot lights) Pilot ight A8H-P1➁ ED lamps do not have a current-limiting resistor. onnect a current-limiting resistor in series, otherwise ED lamps will be damaged. AP8M series pilot lights (round bezel only) with built-in current-limiting resistor are also available. Pilot lights are not certified. Dimensions (+) ( ) Panel Thickness 0. to 6 2. ocking ing Terminal Width t ectangular ound ø9. 12 c 9 ø Terminal Arrangement N Mounting Hole ayout ound/ Units ø8 0 ectangular Units ø8 0 amp Terminal (+) NO OM amp Terminal ( ) 9 min. 9 min. 9 min. 12 min. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. 36

37 A8 Series Accessories ø8 Pushbuttons ound AB8M Shape Button Style Operation ontact Button Part No. IP40 SPDT AB8M-M1➀ SPDT AB8M-A1➀ Package Quantity: 1 olor ode ➀➁ B black : red S: blue ens SPDT AB8M-M1➁ SPDT AB8M-A1➁ A: amber : red AB8Q Button SPDT AB8Q-M1➀ SPDT AB8Q-A1➀ B black : red S: blue ens SPDT AB8Q-M1➁ SPDT AB8Q-A1➁ A: amber : red ectangular AB8H Button SPDT AB8H-M1➀ SPDT AB8H-A1➀ B black : red S: blue ens SPDT AB8H-M1➁ SPDT AB8H-A1➁ A: amber : red Specify a color code in place of ➀ or ➁ in the Part No. ens style buttons can be used with marking plate and film. Dimensions Panel Thickness 0. to 6 2. ocking ing Terminal Width t ectangular ound c 9 ø Terminal Arrangement (bottom view) Mounting Hole ayout N ound/ Units ø8 0 ectangular Units ø8 0 NO OM 9 min. 9 min. 9 min. 12 min. Note: Determine mounting centers to ensure easy operation. All dimensions in mm. 37

38 ø8 A8 Series Accessories Accessories ocking ing Wrench ens emoval Tool Shape Material Part No. 60 ø9 Ordering Part No. Package Quantity Metal (nickel-plated brass) MT-004 MT emarks Used to tighten the locking ring when installing the A8 series into a panel. Stainless Steel MT-101 MT Used to remove the lens and button. 60 amp Holder Tool 70 Switch Guard Socket Terminal over Mounting Hole Plug ubber O-66 O open For round/ square Unit For rectangular unit Used to remove and install the ED lamps. A-K8 A-K8 1 Used to protect pushbuttons from inadvertent operation. See page 38 for A-KH8 A-KH8 1 dimensions. Solder Terminal A-8 A-8 1 P Board Terminal A-8V A-8V 1 Nylon A-V8 A-V8PN10 10 Snaps on the rear of the A8 series. (see page 38 for dimensions) When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. Terminal cover is not attached and must be ordered separately. Nitryl rubber (black) A-B8 A-B8PN0 Degree of protection: IP6 (remains 90 open) Dimensions Switch Guard For ound/ Units (A-K8) 10 For ectangular Units (A-KH8) Panel Thickness 0. to min min min. 13 min. Socket (A-8, A-8V) Terminal t Terminal Arrangement N NO Holes amp Terminal (+) OM amp Terminal ( ) Terminal over (A-V8) Solder Terminal (A-8) P Board Terminal (A-8V) 17.3 (P Board Terminal Mounting Hole ayout) (Bottom View) 33. ø9.1 Note: When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. All dimensions in mm. 38

39 A8 Series Accessories ø8 Maintenance Parts Shape Part No. Ordering Part No. Marking Plate ound A8M-W A8M-WPN0 A8Q-W A8Q-WPN0 ectangular A8H-W A8H-WPN0 Package Quantity White olor ode ➀➁ ens Unit ound A8M-K1-➁ A8M-K1-➁PN02 Specify a color code in place of ➁ in the Part No. A8Q-K1-➁ A8Q-K1-➁PN02 A (amber), G (green), (red) ectangular A8H-K1-➁ A8H-K1-➁PN02 W (white), Y (yellow) 2 Button Unit ound AB8M-BK1-➀ AB8M-BK1-➀PN02 Specify a color code in place of ➀ in the Part No. AB8Q-BK1-➀ AB8Q-BK1-➀PN02 B (black), G (green), (red) ectangular AB8H-BK1-➀ AB8H-BK1-➀PN02 S (blue), W (white), Y (yellow) ED amp urrent-limiting resistor is not contained ø4.0 All dimensions in mm. Illumination color: amber Illumination color: green Illumination color: red Illumination color: yellow AD-SA AD-SG AD-S AD-SY AD-SA 1 AD-SAPN10 10 AD-SG 1 AD-SGPN10 10 AD-S 1 AD-SPN10 10 AD-SY 1 AD-SYPN10 10 ens color Amber Green ed White/ Yellow ED color: amber clear ED color: yellow diffused ED color: clear red ED color: yellow clear Safety Precautions Turn off the power to A series before starting installation, removal, wiring, maintenance, and inspection of the units. Failure to turn power off may cause electrical shocks or fire hazard. To avoid burning your hand, use the lamp holder tool when replacing lamps. For wiring, use wires of a proper size to meet the voltage and current requirements. Failure to tighten terminal screws may cause overheating and create a fire hazard. Operating Instructions eplacement of ens and Marking Plate emoval emove the operator (color lens, marking plate, lens holder, and spring) by holding the color lens recesses with the ens emoval Tool (MT-101) and pulling it out. emove the marking plate by disengaging the latches between the color lens and lens holder. The marking plate must be engraved on the front side as shown below. atches Installing Non-illuminated Button Non-illuminated pushbuttons contain a marking plate like illuminated units. Be sure to install the marking plate when replacing the button. Marking For A series illuminated pushbuttons, legends and symbols can be engraved on the built-in marking plates, or printed film can be inserted under the lens. Marking Plate & Engraving Area ens ound ectangular Note: Make sure that the spring is inserted in the correct direction. The base of spring must fit the groove in the holder. Installation Engraving Area olor lens Marking Plate Spring ens etaining Holder Groove Spring Place the marking plate on the lens holder in the correct direction, and press the color lens onto the lens holder to engage the latches. Put the spring on the lens holder and insert the lens holder into the housing in the correct direction. Built-in Marking Plate ø 0.8 Engraving Area Size: ø Engraving Area Engraving must be made on the engraving area less than 0.mm deep. The marking plate is made of white acrylic resin. Size: Engraving Area 8 Size: 9.1 x

Bright illumination face and snap-action switching.

Bright illumination face and snap-action switching. ø A2 Series ø10 A1 Series ø8 A8 Series A2 Series A1 Series A8 Series Bright illumination face and snap-action switching. See website for details on approvals and standards. Hole Size Model Function Degree

More information

A Series. Miniature Control Units

A Series. Miniature Control Units TEIH-ATM Electronic Auf der Bült 10-12 D 41189 Mönchengladbach Tel. 02166 958545 Fax 02166 958547 email: atm@treichl.de internet: A Series Miniature ontrol Units A Series Miniature ontrol Units Series

More information

[ Bezel size ] [ From panel front ] [ Shape ] [ Contact rating ] [ Action ] Unibody

[ Bezel size ] [ From panel front ] [ Shape ] [ Contact rating ] [ Action ] Unibody and Series Suitable for a wide variety of office and factory aplications. Features IE s original mechanism for snap-action switching. The E lamp contains a current-limiting resistor and a diode for protection

More information

ø12 A2 Series Miniature Control Units

ø12 A2 Series Miniature Control Units ø2 A2 Series Miniature Control Short 22-mm-long body miniature control unit series with bright LED illumination face and snap-action switching. Degree of protection: IP40 and IP5 (IEC 0529) All series

More information

ø8 A8 Series Miniature Control Units

ø8 A8 Series Miniature Control Units A8 ø8 A8 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals

More information

ø10 A1 Series Miniature Control Units

ø10 A1 Series Miniature Control Units A1 ø10 A1 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - A6 Series A6 Series Miniature Switches and Pilot Devices: 16mm Key features: 16mm (/8 ) mounting hole ED illumination ompact design saves space Momentary, Maintained, Selectors, and E-Stops Gold-clad

More information

Miniature Switches & Pilot Devices

Miniature Switches & Pilot Devices ø16mm - 6 Series Miniature 6 Series Miniature Switches and Pilot Devices Key features of the 5/8 6 Series include: 5/8 (16mm) mounting holes ocking lever removable contact blocks Solder terminal or PB

More information

MW Series Control Units

MW Series Control Units IP waterproof and dust-proof enclosure Suitable for installation in harsh environment, such as construction machines Prevents entry of sand and dust. eliable operation under high operation load Solder/tab

More information

Miniature Switches & Pilot Devices

Miniature Switches & Pilot Devices A8 Series Miniature Switches and Pilot Devices: 8mm Key features of the 21/64" (8mm) A8 series Switches and Pilot Devices include: 21/64" (8mm) round mounting hole Compact Design Saves Space Bright and

More information

LW Series offer flexibility in space-saving package

LW Series offer flexibility in space-saving package ourtesy of Steven Engineering, Inc. 230 yan Way, South San Francisco,, 94080-6370 Main Office: (650) 588-9200 Outside Local rea: (800) 258-9200 www.steveneng.com LW Series offer flexibility in space-saving

More information

ø22mm HW Series Control Units Control Units

ø22mm HW Series Control Units Control Units mm HW Series Control Units Control Units HW Series Control Units (Selection Guide) Function Emergency Stop Switch (Unibody Type) Emergency Stop Switch (Separate Type) Pushlock Turn eset Category ø40mm

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - 6 Series 6 Series Miniature Switches and Pilot Devices Key features of the 5/8 6 Series include: 5/8 (16mm) mounting holes ocking lever removable contact blocks Solder terminal or PB terminal options

More information

ø25mm TWS Series Control Units

ø25mm TWS Series Control Units ø25mm TWS Series ontrol Units ø25 TWS Series ontrol Units (Selection Guide) Function ategory Flush Extended Pushbutton Extended with Half Shroud Momentary/ Extended with Full Shroud Mushroom Shape ABS1

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - 6 Series Key features: 5/8 (16mm) mounting holes ocking lever removable contact blocks Solder terminal or PB terminal options Available assembled or as sub-components Worldwide approvals Incandescent

More information

ø22mm LW Series Control Units

ø22mm LW Series Control Units ø22mm W Series ontrol Units ø22 W Series ontrol Units (Selection Guide) Function ategory ound Flush Square Flush Pushbutton ound Flush with Square Bezel Momentary/ ound Extended Square Extended W1B- 1

More information

Switches & Pilot Devices

Switches & Pilot Devices Selection Guide... 45 Miniature... 45 AP Series ø8-6mm... 45 A8 Series ø8mm... 456 ø6mm... 46 A E-Stops ø6mm... 46 B Series ø6mm... 468 6 Series ø6mm... 5 ømm... 55 W E-Stops ømm... 55 W Series ømm...

More information

AP/UP Series Miniature Pilot Lights UZ Series Miniature Buzzer

AP/UP Series Miniature Pilot Lights UZ Series Miniature Buzzer AP/UP Series Miniature Pilot Lights UZ Series Miniature Buzzer Pilot Lights / Buzzer Selection Guide Series AP Series Miniature Pilot Lights AP6S Series Miniature Pilot Lights Mounting Hole Size ø6 ø2

More information

UP Series Miniature Pilot Lights

UP Series Miniature Pilot Lights Available in Various Sizes Five illumination colors: amber, green, red, white, yellow Various sizes and design. Available with a built-in current limiting resistor. Waterproof () types available for and.

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Non-Illuminated ushbuttons (Sub-Assembled) Contact Block + Operator + Button = Completed Unit art Numbers: Operators Style art Number Momentary Maintained LW1B-M0 LW1B-A0 LW2B-M0 LW2B-A0 Mushroom

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: Two button sizes: ø29 and ø4mm ead-free, ohs compliant, (EU directive 22/95/EC) Depth behind the panel: Standard - only 27.9mm for 1 to 4 contacts Unibody - only 23.9mm for 1NC or 2NC IDEC

More information

LW Silhouette Series. Illuminated Key Selector Switches Pushbuttons and Illuminated Pushbuttons with Round Guard. LW Silhouette Switches

LW Silhouette Series. Illuminated Key Selector Switches Pushbuttons and Illuminated Pushbuttons with Round Guard. LW Silhouette Switches W Silhouette Series Illuminated Key Selector Switches Pushbuttons and Illuminated Pushbuttons with ound Guard W Silhouette Switches W Silhouette Series Illuminated Key Selector Switches The two-way split

More information

VH Super Miniature Lighted Pushbutton Switch. Only 10.6mm depth behind panel permits space saving on machinery.

VH Super Miniature Lighted Pushbutton Switch. Only 10.6mm depth behind panel permits space saving on machinery. Super Miniature Lighted Pushbutton Switch Only 10.6mm depth behind panel permits space saving on machinery. Flanged type for panel mounting and without flange type for PB available. FEATUES Depth behind

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB ø22mm XW E-Stops Circuit Breakers Terminal Blocks ors Timers elays & Sockets Signaling ights 22mm XW E-Stops Key features: The depth behind the panel can be as little as 46.4 mm for 1 to 4 contacts (with

More information

22mm XW E-Stops. UL File #E68961 CCC No Specifications

22mm XW E-Stops. UL File #E68961 CCC No Specifications XW Series 22mm XW E-Stops Key features: The depth behind the panel is only 48.7 mm for 1 to 4 contacts (with terminal cover) for illuminated and non-illuminated units. IDEC s original Safe break action

More information

Full-Face, Split-Face, Dual-Color with built-in resistor. Oil and Water-Tight Version to IP65 available.

Full-Face, Split-Face, Dual-Color with built-in resistor. Oil and Water-Tight Version to IP65 available. Miniature Lighted Pushbutton Switch KH Full-Face, Split-Face, Dual-olor with built-in resistor. Oil and Water-Tight Version to IP65 available. FEATUES mm (.67 ) mounting hole. Depth behind panel : Only

More information

XW Series E-Stops. Safety. Selection Guide ø22mm XW E-Stops

XW Series E-Stops. Safety.  Selection Guide ø22mm XW E-Stops Safety Selection Guide... 288 ø22mm XW E-Stops... 289 www.idec.com/usa/estop XW Series E-Stops Overview Interlock Switches Enabling Switches Safety Control ight Curtains AS-Interface Safety at Work Table

More information

XW Series Emergency Stop Switches

XW Series Emergency Stop Switches ø ø mm, 4-contact Emergency Stop Switch. Compact size only 37. mm deep behind the panel (screw terminal type 4 mm with terminal cover). eliable Safe break action. The depth behind the panel is only 37.

More information

Style Contact Type No. Button Color Code ø40mm Mushroom 1NC YW1B-V4E01R YW1B-V4E21R. Gasket ø40 YW1L-V4E11Q0R 2NC YW1L-V4E02Q➂R 6 (12V AC/DC)

Style Contact Type No. Button Color Code ø40mm Mushroom 1NC YW1B-V4E01R YW1B-V4E21R. Gasket ø40 YW1L-V4E11Q0R 2NC YW1L-V4E02Q➂R 6 (12V AC/DC) Pushlock Pull/Turn eset Style Contact Type No. Button Color Code ø40mm Mushroom NC YWB-V4E0 2NC 3NC NO-NC NO-2NC 2NO-NC YWB-V4E02 YWB-V4E03 YWB-V4E YWB-V4E2 YWB-V4E2 ed only Dimensions Panel Thickness

More information

XA Series Emergency Stop Switches (w/removable Contact Block)

XA Series Emergency Stop Switches (w/removable Contact Block) XA ø6 XA Series Emergency Stop Switches (w/removable Contact Block) The World s First ø6 mm, 4-contact Emergency Stop Switch. Compact size - only 7.9 mm deep behind the panel. Reliable Safe break action.

More information

XW Series E-Stops. Safety. ø22mm XW E-Stops Phone: Fax: Web: -

XW Series E-Stops. Safety. ø22mm XW E-Stops Phone: Fax: Web:  - Safety ø22mm XW E-Stops... 277 XW Series E-Stops Overview Interlock Switches Enabling Switches Safety Control ight Curtains AS-Interface Safety at Work Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com

More information

AP Series / UP Series Miniature Pilot Lights UZ Series Miniature Buzzer

AP Series / UP Series Miniature Pilot Lights UZ Series Miniature Buzzer AP Series / UP Series Miniature Pilot Lights UZ Series Miniature Buzzer Pilot Light / Buzzer Selection Guide Series AP Series Miniature Pilot Lights AP6S Series Miniature Pilot Lights Mounting Hole Size

More information

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches Standard Interlock Safety Switches HS6B HS5E-K Key Locking Safety Key features: Head removal detection circuitry. High-security pin tumbler key types are used. Sixteen types of key numbers are available,

More information

ø22mm HW Series Control Units

ø22mm HW Series Control Units TREICHL-ATM Electronic Auf der Bült 10-12 D 41189 Mönchengladbach Tel. 02166 958545 Fax 02166 958547 email: atm@treichl.de internet: mm HW Series Control Units HW Series Control Units (Selection Guide)

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive haracteristics arefully designed light diffusion and filtering system produces bright, full surface illumination with front panel relamping. Spot illumination available in single and bicolor

More information

Only 21.5mm depth behind panel with LED Full Face, Illumination.

Only 21.5mm depth behind panel with LED Full Face, Illumination. R LED Lamp Subminiature Lighted Pushbutton Switch Only 21.5mm depth behind panel with LED Full Face, Illumination. FEATURES Depth behind panel:only 21.5mm. LED Full Face Illumination provided. size: 14.2mm

More information

LUMIFA LED Light Strips Long-lasting & so bright you gotta wear shades!

LUMIFA LED Light Strips Long-lasting & so bright you gotta wear shades! LUMIFA LED Light Strips Long-lasting & so bright you gotta wear shades! LF1A Series shown As IDEC continues to move towards a green future, we are excited to announce the LUMIFA series of LED light strips,

More information

General Specifications

General Specifications Series HB Subminiature Pushbuttons General Specifications Electrical apacity (Resistive Load) Power Level (silver): 0.1A maximum @ 30V A/ Other Ratings ontact Resistance: 50 milliohms maximum Insulation

More information

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid HS1L Interlock Switches with Solenoid 3000N locking strength (largest in class)! * Suitable for large and heavy doors. Same actuator as HS1E (actuator retention force 3000N) Six contacts in a compact housing

More information

We Make It Easy! 3. All of our switches are shipped complete, just as ordered. No incomplete or partial deliveries of subcomponents and accessories

We Make It Easy! 3. All of our switches are shipped complete, just as ordered. No incomplete or partial deliveries of subcomponents and accessories We Make It Easy! 1. We assemble the parts for you saves you time and money. Includes LEDs and accessories 2. Easy to order all options and accessories displayed in easy-to-follow ordering table. No complicated

More information

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm Emergency Stop Switch Mounting Aperture of 16 mm Modular construction, easy installation Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, Conforms to EN418

More information

Only 22.5mm depth behind panel with built-in resistor

Only 22.5mm depth behind panel with built-in resistor Miniature Lighted Pushbutton Switch R Only.mm depth behind panel with built-in resistor Bright and Variable Illumination makes easy planning of multiple design. FEATURES Depth behind panel : Only.mm LED

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Full face or spot illumination with incandescent lamps or multi-element LEDs, with or without resistors. Choice of super bright LEDs in white, green, and blue as well as bright

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Full face or spot illumination with incandescent lamps or multi-element LEDs, with or without resistors. Short Body Pushbuttons Series YB Choice of super bright LEDs in white,

More information

Illuminated pushbutton, non-illuminated pushbutton, selector, key selector switches

Illuminated pushbutton, non-illuminated pushbutton, selector, key selector switches ND Series: 16 dia. types (AEL, ABL, ASL, AKL) Illuminated pushbutton, non-illuminated pushbutton, selector, key selector switches Bright, clear illumination (ultra-high intensity LED used) Separate mounting

More information

General Specifications

General Specifications Standard Size Pushbuttons General Specifications Electrical apacity (Resistive Load) Power Level (silver): 3A @ 125V A or 3A @ 250V A or 3A @ 30V Logic Level (gold): 0.4VA maximum @ 28V A/ maximum (Applicable

More information

Only 22.5mm depth behind panel with built-in resistor

Only 22.5mm depth behind panel with built-in resistor Miniature Lighted Pushbutton Switch R Only.mm depth behind panel with built-in resistor Bright and Variable Illumination makes easy planning of multiple design. FEATURES Depth behind panel : Only.mm LED

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Switches & Pilot Devices HW Series 22mm IEC Style Global Pushbuttons Circuit Breakers Terminal Blocks Timers Relays & Sockets Display Lights Switches & Pilot Lights Key features include: Locking

More information

ø25 TWS Series Switches & Pilot Lights

ø25 TWS Series Switches & Pilot Lights ø25 TWS Series Switches & Pilot Lights General-purpose switches & pilot lights for various applications Heavy-duty type for high-level protection against harsh environment No terminal cover required (except

More information

Enabling Switches Grip Style Enabling Switches

Enabling Switches Grip Style Enabling Switches Enabling es Grip Style Enabling es What is an enabling switch? Because operators use teach pendants in hazard ous environments performing teaching, system changeover, and maintenance of robots, they must

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Emergency Stop Stations Part Numbers: Emergency Stop Stations Description Contacts Plastic Bezel Metal Bezel Ø 40mm Pushlock Turn Reset 1NO-1NC HW1X-BV411-R* HW4X-BV411-R* 2NC HW1X-BV402-R* HW4X-BV402-R*

More information

ø30mm Series Switches & Pilot Lights

ø30mm Series Switches & Pilot Lights ømm Series Switches & Pilot ights ø ø Series Switches & Pilot ights (Selection Guide) Function ategory XN Series Emergency Stop Switch HN Series Emergency Stop Switch Plastic Bezel Flush Bezel Padlockable

More information

HS1C-P Interlock Plug Unit with Door Lock

HS1C-P Interlock Plug Unit with Door Lock HSC-P Unit with Lock Interlock plugs with door lock mechanism for high level safety management. Installing the actuator on the guard door and the interlock switch on the machine, the guard door can be

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

Switches & Pilot Devices

Switches & Pilot Devices ømm - HW Series Key features: Locking lever removable contact blocks Finger-safe IP contacts Tamperproof construction All E-stops meet EN6947-5-5, and are compliant with SEMI S standards Worldwide approvals

More information

Enabling Switches. Safety. Selection Guide

Enabling Switches. Safety.   Selection Guide Safety Selection Guide... 365 Panel Mount... 366 HE1B Series... 366 HE2B Series... 368 HE3B Series... 371 HE5B Series... 374 HE6B Series... 377 Grip... 380 HE1G Series... 380 HE1G-L Series... 384 HE2G

More information

Indicator body round for raised full face, black plastic, 22.5 mm mounting. Part No For complete switch also order

Indicator body round for raised full face, black plastic, 22.5 mm mounting. Part No For complete switch also order Series 14.5 mm 0.5 mm IP67 5 50 V INDITOR pushbutton keylock selector buzzer hoose one component from each of the coloured sections to assemble a complete switch. Product Profile Indicator The Series 14

More information

KFD / KFT / KFR Series

KFD / KFT / KFR Series Incandescent Annunciator Lights KF / KFT / KFR Series KF-27F 27H 27V KF-37F 37H 37V KF-50F 50H Features Available in a variety of lighting panel sizes. 12 indicators (8 flat and 4 diagonal models) ranging

More information

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches HS5D Miniature Interlock Switches Head Removal Detection Function for Safer Performance Clearwater Tech - Phone: 8094.04 - Fax: 8.368.04 - Web: www.clrwtr.com - Email: info@clrwtr.com New Generation Miniature

More information

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches Head removal detection for safer performance. Head removal detection function turns OFF the main circuit (-) when the head of the is removed. The is the same size as contact interlock switches (HS5B).

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

Indicator Lights (Neon, LED and Filament Lamp)

Indicator Lights (Neon, LED and Filament Lamp) Indicator ights (Neon, ED and Filament amp) Colours and voltages: Neon Red, Amber, Green, Clear 100/130V (marked 110V), 200/250V (marked 230V) ED Red, Yellow, Green /2.2V Resistors for other voltages available

More information

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch Edition 10/2016 HMI Components Series Characteristics The compact Series is especially suited for: Flush design The large rectangular design (24x36mm) features a large illuminated area. Functions The Series

More information

A22/M22. Specifications. Specifications Common to All. Complete Assemblies

A22/M22. Specifications. Specifications Common to All. Complete Assemblies Complete Assemblies Specifications Common to All A22/M22 The Following Pages Provide Information Common To Each Model of The A22/M22 Pushbutton Switch H A22 H A22S/W H A22K H M22 Specifications J APPROVED

More information

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1 S P E C I F I C A T I O N Edition 2 Page 1 ECS - INDUSTRIAL CONTROL SWITCH SELECTOR 1. FEATURES Up to 5 different operations. Detachable contact block for easy installation and removal. It can meet variety

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Various cap styles and colors to meet differing application needs. Bright, full face illumination to distinctively indicate status. Rear panel threaded mounting or snap-in mounter

More information

General Specifications

General Specifications General Specifications Electrical Capacity (Resistive oad) Power evel (silver): 3A @ 125V AC or 3A @ 250V AC or 3A @ 30V C ogic evel (gold): 0.4VA maximum @ 28V AC/C maximum (Applicable Range 0.1mA ~ 0.1A

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Full face and spot illumination available. Front panel relamping. Choice of super bright LEDs in white, green, and blue in addition to bright red, amber, and green LEDs. Compact

More information

3 CE-Conformity. General information. Signal lamps. 3-2 Signal lamps

3 CE-Conformity. General information. Signal lamps. 3-2 Signal lamps Signal lamps General information Signal Lamps with integral lamps/s The soldered lamps/s without base cannot be replaced. Signal Lamps with lamp socket An integral lamp socket allows replacement of lamps/s

More information

Push Button Units and Indicator Lights

Push Button Units and Indicator Lights 3SB3, Inscriptions, 22 mm Insert labels Push Button Units and Indicator Lights Push buttons (clear) and illuminated push buttons with a flat button can be fitted with insert labels for identification purposes,

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series RAS RA Key features of the RA series include: Available in 4 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over

More information

HS1C Interlock Switches with Solenoid

HS1C Interlock Switches with Solenoid HSC es with The guard door remains locked until the machine stops completely. With the actuator mounted on the guard door and the interlock switch on the machine, the door is mechanically locked when closed.

More information

HS1E-K Interlock Switches with Solenoid (3-circuit)

HS1E-K Interlock Switches with Solenoid (3-circuit) HS1E-K Interlock Switches with Solenoid (-circuit) Dual main circuit + lock monitor circuit provide more safety to your system Basic unit and solenoid unit in one housing Lightweight plastic housing All

More information

Only 35mm depth behind panel with built-in resistor

Only 35mm depth behind panel with built-in resistor Lighted Pushbutton Switch R LED Only 5mm depth behind panel with built-in resistor Reliable Push-Feeling and valiable illumination Full-Face, Split-Face(,, ). FEATURES Depth behind panel : Only 5mm LED

More information

General Specifications

General Specifications Series JW High Inrush 0 & 6 Amp Rockers Touch Tilt Rockers Toggles Slides Rotaries Programmable Illuminated P Pushbuttons Supplement Accessories Indicators Tactiles Keylocks General Specifications Electrical

More information

Indicators. Introduction

Indicators. Introduction Introduction Indicators This range of panel mounting ED indicators consists of many different bezel styles, types of ED s and colours. The range has developed to meet the different needs of panel design

More information

High reliability EH-N type

High reliability EH-N type / -N Miniature Lighted Pushbutton Switch RoHS Only.mm depth behind panel with built-in resistor Bright and Variable Illumination makes easy planning of multiple design. FEATURES Depth behind panel : Only.mm

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Carefully designed light diffusion and filtering system produce bright, full surface illumination with front panel relamping. Spot illumination available in single and bicolor

More information

Lighted PushButton Switch

Lighted PushButton Switch Lighted PushButton Switch Cylindrical 8mm dia. Subminiature Series Featuring Short Mounting Depth Round, square and rectangular LED pushbutton units. types also available. Requires only 18mm mounting depth.

More information

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches DC-Wire Spatter-Guarded Cylindrical Proximity Switches FL7M Series A variety of anti-spatter measures make these switches the optimum for welding processes on the automotive production line. With Teflon

More information

3.2. Pushbuttons. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

3.2. Pushbuttons. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents . Pushbuttons Product Description Eaton offers a wide range of pushbutton switches for standard industry applications such as appliances, electronics, medical and test instrumentation, office equipment

More information

High reliability EH-N type

High reliability EH-N type / EH-N Miniature Lighted Pushbutton Switch RoHS EH Only.mm depth behind panel with built-in resistor Bright and Variable Illumination makes easy planning of multiple design. FEATURES Depth behind panel

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with

More information

A22NK. Key-type Selector Switches

A22NK. Key-type Selector Switches Key-type Selector Switches -mm dia. Key-type Selector Switches Control panel miniaturization through a more compact design and modified wiring direction. Addition of Push-In Plus terminal blocks for easy

More information

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm Emergency Stop Switch For Panel Cutout of 16 mm H Modular construction, easy installation H Positive opening mechanism with a minimum contact separation of 3 mm in accordance with EN6947-5-1, for NC contacts

More information

Subminiature Basic Switch

Subminiature Basic Switch Subminiature Basic Switch Subminiature Basic Switch Offers Long Life and High Reliability A design that combines simplicity and stability by the use of two split springs ensures a long durability of 30,000,000

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Wide selection of illumination effects is achieved with single and bicolor, - or -element LEDs, in flat, beveled, or sculptured caps. LED colors include red, amber, green, white,

More information

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series Industrial Automation Catalog Section - U906 Relays Selection Guides General Purpose Relays RU Series RR Series For up-to-date information, or to request a full copy of this catalog, contact us at www.idec.com

More information

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less. INUCTIVE SERIES Compact Inductive Proximity Sensor Flexible cable Metal embedding type available possible Amplifier Built-in High functionality together with robust housing and flexible cable GA-/GH -N

More information

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse. Switch A22E Install in 22-dia. or 25-dia. Panel Cutout Direct opening mechanism to open the circuit when the contact welds. Safety lock mechanism prevents operating errors. Easy mounting and removal of

More information

HS5E Miniature Interlock Switches with Solenoid

HS5E Miniature Interlock Switches with Solenoid Small interlock switch with four poles and solenoid. Ideal for applications in small spaces. Compact body. 3 40 46 mm. Four-pole internal switches. Gold-plated contacts. Spring lock and solenoid lock types

More information

Tactile Switch (Hinged Type)

Tactile Switch (Hinged Type) Tactile Switch (Hinged Type) Hinged Design Developed through Ergonomics Quick, superior snap action through hook-type hinge construction. Available with 1 or LEDs or without LEDs. The hinge button is available

More information

General Specifications

General Specifications Series UB Low Profile Pushbuttons General Specifications Electrical Capacity (Resistive Load) Power Level (silver): 5A @ 5/50V AC or 5A @ 0V C Logic Level (gold): 0.VA maximum @ 8V AC/C maximum (Applicable

More information

General Specifications

General Specifications Series UB Low Profile Pushbuttons General Specifications Electrical Capacity (Resistive Load) Power Level (silver): 5A @ 5/50V AC or 5A @ 0V C Logic Level (gold): 0.VA maximum @ 8V AC/C maximum (Applicable

More information

HS1E Series Full Size Solenoid Locking Switches

HS1E Series Full Size Solenoid Locking Switches HS1E Series Full Size Solenoid Locking Switches AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview HS1E features: Basic unit and solenoid unit in one

More information

YB2 Panel Seal. New Square Actuator Option. Series YB2. Contact No Thin Flush Mount Pushbuttons. 24mm Square Panel Seal Pushbuttons

YB2 Panel Seal. New Square Actuator Option. Series YB2. Contact No Thin Flush Mount Pushbuttons. 24mm Square Panel Seal Pushbuttons Contact No. 182 YB2 Panel eal Thin Flush Mount Pushbuttons New quare Actuator Option 2011-01-26 www.nkk.com 1 General pecifications Electrical Capacity (Resistive Load) Power Level (silver): 3A @ 125V

More information

Indicator body single with two independent lamp bases, raised, rectangular, black plastic, screw terminals, without bezel. Part No

Indicator body single with two independent lamp bases, raised, rectangular, black plastic, screw terminals, without bezel. Part No Series 03. mm x 4. mm IP40/IP65 0 A 400 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales

More information

SWITCHES. Other switch types include conventional, push-button and toggle switches.

SWITCHES. Other switch types include conventional, push-button and toggle switches. Switches Manufactured from Stainless Steel, Bulgin s extensive range of vandal resistant security switches are designed with a high resistance to wear and tear, corrosion and harsh use in potentially hostile

More information

Indicator Lights Neon, LED and Filament Lamp

Indicator Lights Neon, LED and Filament Lamp Indicator ights Neon, ED and Filament amp Colours and voltages: Neon Available with Red, Amber, Green or Clear lenses 100/130V (marked 110V), 200/250V (marked 230V) ED - Red, Yellow, Green, Blue, White

More information