AP Series / UP Series Miniature Pilot Lights UZ Series Miniature Buzzer

Size: px
Start display at page:

Download "AP Series / UP Series Miniature Pilot Lights UZ Series Miniature Buzzer"

Transcription

1 AP Series / UP Series Miniature Pilot Lights UZ Series Miniature Buzzer

2 Pilot Light / Buzzer Selection Guide Series AP Series Miniature Pilot Lights AP6S Series Miniature Pilot Lights Mounting Hole Size ø6 ø2 ø0 ø8 ø6 Type AP6M AP2M APM AP8M AP6MS / AP6QS / AP6HS 3.5mm 2.5mm 3.5mm 2.5mm.5mm 0 mm 2.5mm 2.5mm.5mm mm Appearance 3.5mm mm.5mm.5mm.5mm 8.5mm Unit Round, Square, Rectangular, Rectangular 3-sided barrier Bezel Size ø8 ø4 ø2 ø.8 ø (AP6MS) (AP6QS) (AP6HS, AP6GS) Bezel Color Black Black Light Source Built-in LED LED lamp (IDEC LSTD) Illumination Color Amber, Green, Red,, Yellow Amber, Green, Pure, Red, Blue,, Yellow Amber, Green, Red, Blue,, Yellow Rated Voltage 6V, 2V, 24V DC 5V DC 2V, 24V AC/DC 6V, 2V, 24V AC/DC Degree of Protection Waterproof, oiltight () Enclosed type () Waterproof () Terminal Style Solder terminal Screw terminal (M2.6) Solder/tab terminal #0 Notes 00/0V AC, 200/220V AC adapter available. 0V DC (0V to 40V DC) DC-DC converter units available. Flashing units (2/24V DC) available. Built-in current limiting resistor and protection diode. Marking is available on flat lens. Built-in current limiting resistor and protection diode. Marking is available on flat lens (except ø8). Waterproof type (degree of protection ) available (except ø8). Built-in BAS base LED lamp. Built-in current limiting resistor and protection diode in LED lamp. Screw terminals and solder/tab terminals available. Approvals Page

3 Pilot Light / Buzzer Selection Guide UP Series Miniature Pilot Lights ø0 ø ø8 ø7 ø6 UP / UPP UP / UPP UP8 UP7 UP06 Series Mounting Hole Size Type UZ series Miniature Buzzer ø6 UZ6 2.5mm Appearance mm Buzzer Unit Cyclical Sound Adapter (for pulsing sound) 6 types 6 types 6 types 6 types 3 types Unit Buzzer unit Continuous sound ø2 ø ø0 ø ø7.5 Bezel Size ø8 Chrome-plated (Metal) Bezel Color Black (buzzer unit: blue) Built-in LED Amber, Green, Red,, Yellow Without a built-in current limiting resistor With a built-in current limiting resistor (24V DC) Enclosed type () Waterproof, oiltight () Enclosed type () Without a built-in current limiting resistor only Rated Voltage Sound Pressure and Frequency Sound Cycle 2/24V DC Cyclical sound adapter 2/24V DC 75 db (at m) at rated voltage, 3.5 khz ±800 Hz Adjustable between 30 to 600 cycles per minute (period 2 to 0. sec) Solder terminal Solder terminal LED miniature pilot lights available with current limiting resistor (except ø6). Waterproof (degree of protection ) (ø0 and ø) Single board mounting applicable types also available (except ø7 and ø6). Degree of Protection Terminal Style Notes Enclosure type () (Buzzer unit) Solder terminal (cyclical sound adapter screw terminal M8) Same size and same terminal arrangement as AP6M series miniature pilot lights. The intermittent sound adapter can be snapped on to the back of the buzzer unit. LA3Z buzzer (rectangular) also available. See L6 series Control Units catalog for details. 6, 2 7, 2 8, 2 Page 23 3

4 ø AP Series Miniature Pilot Lights Super Bright LEDs with built-in current-limiting resistor and reverse polarity protection diode Space saving miniature style Long life Illumination colors: amber, blue, green, pure white, red, white, and yellow (blue and pure white available for AP8M and APM only) Marking is available on flat lens units. (except AP8M series) Built-in protection diode ensures a reverse withstand voltage of 00V. UL recognized and CSA certified AP6M Series AP2M Series AP6M Series APM Series AP8M Series AP2M Series APM Series AP6M Series AP2M Series AP8M Series AC adapter unit DC-DC converter unit Flasher unit AC adapter unit DC-DC converter unit Pilot Light Input Type Full voltage Operating Voltage 5V DC 6V DC 2V AC/DC 2V DC 24V AC/DC 24V DC Rated Current AC Adapter/DC-DC Converter (Option) Flasher Unit (Option) Unit AC Adapter DC-DC Converter Applicable Unit AP6M and AP2M (6V rating only) Operating Voltage 00/0V AC, 200/220V AC 50/60 Hz 0V DC (0 to 40V DC) Power Consumption.6 VA maximum W maximum Insulation Voltage 250V AC 40V DC Insulation Resistance Dielectric Strength APM, AP8M: ma (yellow: 5 ma) Between live and dead parts: 00 MΩ minimum (500V DC megger) Between live and dead parts: 2000V, minute Between I/O terminals: 2000V AC/, minute M3 screw Terminal Style Weight (approx.) 38g 20g AP6M, AP2M: 33 ma Between I/O terminals: 500V AC, minute APM, AP8M: ma (yellow: 5 ma) AP6M, AP2M: 22 ma APM, AP8M: ma (yellow: 5 ma) AP6M, AP2M: ma Illumination Color Code AP6M, AP2M: A (amber), G (green), R (red), Y (yellow), W (white) AP8M, APM: A (amber), G (green), PW (pure white), R (red), S (blue), Y (yellow), W (white) Operating Temperature 20 to +55 C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Insulation Resistance Between live and dead parts: 00 MΩ minimum (500V DC megger) Dielectric Strength Between live and dead parts: 000V, minute Reverse Withstand Voltage 00V 00V 00V Solder Terminal Soldering 350 C maximum (3 sec) Applicable Wire ø.0 or 0.75 mm 2 maximum (20 to 6 AWG) Weight (approx.) AP6M: 7.5g AP2M: 4.5g APM: 2.5g AP8M: 2.0g Degree of Protection AP6M, AP2M, APM: AP8M: (according to IEC 6052) Applicable Unit AP6M (2V and 24V DC rating only) Operating Voltage 2/24V DC compatible ±0% Flashing Period Adjustable between approximately 30 to 600 cycles per minute (period 0. to 2 sec) Current Draw 4 ma (OFF) to 6 ma (ON) Terminal Style M3 screw Weight (approx.) 3.5g 4

5 AP Series Miniature Pilot Lights ø6 AP6M Series (ø6) Shape Operating Voltage Ordering Lens Color Code AP6M266➁ 6V DC ±5% AP6M266➁ AP6M266➁PN0 0 (marking type) 2V DC ±0% 24V DC ±0% 6V DC ±5% 2V DC ±0% AP6M2➁ AP6M222➁ AP6M66➁ AP6M➁ AP6M2➁ AP6M2➁PN0 0 AP6M222➁ AP6M222➁PN0 0 AP6M66➁ AP6M66➁PN0 0 AP6M➁ AP6M➁PN0 0 Specify a lens color code in place of ➁ in the A: amber R: red Y: yellow AP6M22➁ 24V DC ±0% AP6M22➁ AP6M22➁PN0 0 The LED cannot be removed. The lens can be removed and replaced. Degree of protection: AC Adapter, DC-DC Converter, Flasher Unit Unit Operating Voltage Applicable Pilot Light (Ordering ) 00/0V AC AP6-06D AC Adapter 200/220V AC AP6-026D DC-DC Converter 0V DC (0 to 40V DC) AP6-06DD Flasher Unit 2/24V DC UZ6-F0 AP6M266➁ (dome: 6V DC) AP6M66➁ (flat: 6V DC) AP6M2➁ (dome: 2V DC) AP6M222➁ (dome: 24V DC) AP6M➁ (flat: 2V DC) AP6M22➁ (flat: 24V DC) Dimensions / Panel Cut-out Panel Thickness 0.8 to 6 Gasket With AC Adapter, DC-DC Converter, or Flasher Unit AC Adapter DC-DC Converter Flasher Unit Terminal Cover: AP-VL3 M3 Screw ø8 ø X X 8 ø8 ø Width t Panel Cut-out 0 ø Negative Terminal Terminal cover is not supplied. When using terminal covers, order AP-VL3 terminal covers..5 Terminal Arrangement (Bottom View) Marking Plate ø Negative Terminal Engraving depth: 0.5 mm maximum Marking plate material: acrylic All dimensions in mm. 5

6 ø2 AP Series Miniature Pilot Lights AP2M Series (ø2) Shape Operating Voltage Ordering Lens Color Code AP2M266➁ 6V DC ±5% AP2M266➁ AP2M266➁PN0 0 (marking type) 2V DC ±0% 24V DC ±0% 6V DC ±5% 2V DC ±0% AP2M2➁ AP2M222➁ AP2M66➁ AP2M➁ AP2M2➁ AP2M2➁PN0 0 AP2M222➁ AP2M222➁PN0 0 AP2M66➁ AP2M66➁PN0 0 AP2M➁ AP2M➁PN0 0 Specify a lens color code in place of ➁ in the A: amber R: red Y: yellow 24V DC ±0% AP2M22➁ The LED cannot be removed. The lens can be removed and replaced. Degree of protection: AP2M22➁ AP2M22➁PN0 0 AC Adapter, DC-DC Converter Unit Operating Voltage Applicable Pilot Light 00/0V AC AP2-06D AC Adapter AP6M266➁ (dome: 6V DC) 200/220V AC AP2-026D AP6M66➁ (flat: 6V DC) DC-DC Converter 0V DC (0 to 40V DC) AP2-06DD Dimensions / Panel Cut-out Panel Thickness 0.8 to 6 Gasket With AC Adapter or DC-DC Converter AC Adapter / DC-DC Converter Terminal Cover: AP-VL3 M3 Screw ø4 ø2 5 + X X 8 ø4 ø Width t Panel Cut-out ø Negative Terminal Terminal cover is not supplied. When using terminal covers, order AP-VL3 terminal covers..5 Terminal Arrangement (Bottom View) Marking Plate ø.4 + Negative Terminal 5.5 Engraving depth: 0.5 mm maximum Marking plate material: acrylic All dimensions in mm. 6

7 AP Series Miniature Pilot Lights APM Series (ø0) Shape Operating Voltage Ordering Lens Color Code APM255➁ 5V DC ±5% APM255➁ APM255➁PN0 0 (marking type) 2V AC/DC ±0% 24V AC/DC ±0% 5V DC ±5% 2V AC/DC ±0% APM2➁ APM222➁ APM55➁ APM➁ APM2➁ APM2➁PN0 0 APM222➁ APM222➁PN0 0 APM55➁ APM55➁PN0 0 APM➁ APM➁PN0 0 Specify a lens color code in place of ➁ in the A: amber PW: pure white R: red S: blue Y: yellow 24V AC/DC ±0% APM22➁ The LED cannot be removed. The lens can be removed and replaced. Degree of protection: APM22➁ APM22➁PN0 0 Dimensions / Panel Cut-out ø2 ø0 ø2 ø0 4 - ø0 Panel Thickness 0.8 to 6 Gasket Panel Cut-out ø0..5 Terminal Arrangement (Bottom View) Marking Plate Projection ø Negative Terminal Engraving depth: 0.5 mm maximum Marking plate material: acrylic All dimensions in mm. 7

8 ø8 AP Series Miniature Pilot Lights AP8M Series (ø8) Shape Operating Voltage Ordering Lens Color Code AP8M255➁ 5V DC ±5% AP8M255➁ AP8M255➁PN0 0 2V AC/DC ±0% 24V AC/DC ±0% 5V DC ±5% 2V AC/DC ±0% AP8M2➁ AP8M222➁ AP8M55➁ AP8M➁ AP8M2➁ AP8M2➁PN0 0 AP8M222➁ AP8M222➁PN0 0 AP8M55➁ AP8M55➁PN0 0 AP8M➁ AP8M➁PN0 0 Specify a lens color code in place of ➁ in the A: amber PW: pure white R: red S: blue Y: yellow 24V AC/DC ±0% The lens or LED cannot be removed or replaced. Degree of protection: Dimensions / Panel Cut-out AP8M22➁ AP8M22➁ AP8M22➁PN Panel Thickness 0.8 to 6 Gasket ø.8 ø Panel Cut-out ø.8 ø ø Terminal Arrangement (Bottom View) Projection Negative Terminal All dimensions in mm. 8

9 AP Series Miniature Pilot Lights ø Accessories Shape Type Material Locking Ring Wrench Removal Tool ø6 Ordering MT-00 MT-00 ø2 Metal MT-002 MT-002 ø0 (nickel-plated brass) MT-003 MT-003 ø8 MT-004 MT-004 Stainless steel MT-00 MT-00 Remarks Used to tighten the locking ring when installing an AP unit onto an panel. Tighten the locking ring using a recommended tightening torque. Size 60 Used to remove the AC adapter, DC-DC converter, or flasher unit. 0 Size MT-00 MT-002 MT-003 MT-004 ø8 ø4 ø2 ø.5 6 Mounting Hole Plug ø6 Metal (diecast) Locking ring (plastic) AL-BM6 AL-BM6 Nitryl rubber (black) AL-B6 AL-B6PN05 5 Degree of protection: Degree of protection:.5.0 ø8 ø7.8 ø6.5 6 ø2 Nitryl rubber (black) AL-B2 AL-B2PN05 5 Degree of protection: 4.8 ø4 ø0 Nitryl rubber (black) AL-B AL-BPN05 5 Degree of protection: 4.4 ø Degree of protection: ø8 Nitryl rubber (black) AL-B8 AL-B8PN ø Replacement Parts for AP6M/AP2M/APM Lens Marking Plate Shape Type Diffusion Plate AP6M AP2M APM AP6M Ordering lens AP6M-L2➁ AP6M-L2➁PN05 5 lens AP6M-L➁ AP6M-L➁PN05 5 lens AP2M-L2➁ AP2M-L2➁PN05 5 lens AP2M-L➁ AP2M-L➁PN05 5 lens APM-L2➁ APM-L2➁PN05 5 lens APM-L➁ APM-L➁PN05 5 AP6M-PW AP6M-PWPN05 5 AP2M lens AP2M-PW AP2M-PWPN05 5 APM APM-PNW APM-PNWPN05 5 Lens Color Code A (amber), G (green), R (red), W (white), Y (yellow) (Note ) A (amber), C (clear), G (green), R (red), Y (yellow) (Note 2) A (amber), G (green), R (red), W (white), Y (yellow) (Note ) A (amber), C (clear), G (green), R (red), Y (yellow) (Note 2) A (amber), G (green), R (red), S (blue), W (white), Y (yellow) (Note ) A (amber), C (clear), G (green), R (red), S (blue), Y (yellow) (Note 2) APM lens APM-PN2W APM-PN2WPN05 5 Terminal Cover AP6M AP2M AC adapter DC-DC converter Flasher unit AP-VL3 AP-VL Specify a lens color code in place of ➁ on the Ordering Note : On the dome lens type, use a white (W) lens for white (W) illumination. Note 2: On the flat lens type, use a clear (C) lens for white (W) illumination.

10 ø AP Series Miniature Pilot Lights Safety Precautions Turn off power to the AP series pilot lights before installation, removal, wiring, maintenance, and inspection. Failure to turn power off may cause electrical shocks or fire hazard. For wiring, use wires of proper size to meet the voltage and current requirements. Improper wiring may cause overheating and create a fire hazard. Tighten the M3 terminal screws to a torque of 0.6 to.0 N m. Failure to tighten terminal screws may cause overheating and fire. Instructions Panel Mounting When mounting the AP series pilot lights on a panel, use the optional locking ring wrench. Do not use pliers. Excessive tightening will damage the locking ring. Unit Tightening Torque AP6M 0.88 N m AP2M 0.78 N m APM 0.2 N m AP8M 0.2 N m Installing the AC Adapter, DC-DC Converter, and Flasher Unit. Make sure that the voltage rating and terminal style of the AP series pilot lights are applicable to the AC adapter, DC-DC converter, and flasher units. 2. Install the pilot light into a panel cut-out before mounting an AC adapter, DC-DC converter, or flasher unit. Note that the pilot light cannot be installed in a panel cut-out with an AC adapter, DC- DC converter, or flasher unit mounted. 3. When installing an AC adapter, DC-DC converter, or flasher unit, make sure that the marking is on the same side as the making of the pilot light. AC adapter, DC-DC converter, and flasher unit are snapped on to the back of the pilot light. 4. To remove the AC adapter or DC-DC converter, or flasher unit, insert the tip of the removal tool into the joint hook and pull towards you as shown in the photo below. Wiring. Note the positive and negative polarities when wiring. 2. All DC type AP series pilot lights contain a diode for protection against reverse polarity and a current limiting resistor, eliminating the need for external resistors. 3. Solder the terminal at 350 C within 3 seconds using a 60W soldering iron. SnAgCu type lead-free solder is recommended. When soldering, do not touch the pilot light housing with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. Use a non-corrosive rosin flux. Marking AP6M, AP2M, and APM round flat lenses contain a white marking plate inside the lens. (AP8M lens cannot be removed.) DC-DC Converter DC-DC converters employ an electronic oscillating circuit. Oscillating sounds may be heard depending on operating conditions, but will not affect performance characteristics. Flasher Unit Pierce the round mark on the nameplate on top of the flasher unit with a flat screwdriver and adjust the variable resistor inside.turn clockwise to lengthen the flashing period. X2 Negative Terminal Negative Terminal Nameplate AP2 Series Nameplate X Note: Do not apply excessive force to terminals X and X2 during wiring. X2 Negative Terminal Negative Terminal AP6 Series X X2 Negative Terminal Negative Terminal Nameplate X Note: Do not apply excessive force to terminals X and X2 during wiring. 5. When using an AC adapter or DC-DC converter, or flasher unit where the units are subjected to noise, connect a noise supressor across terminals X and X2 as shown in the diagram below. Noise Suppressor X X2 0

11 AP6S Series Miniature Pilot Lights ø6 Miniature Pilot Lights with Super Bright LEDs IDEC s LSTD LED lamps with BAS base Six illumination colors: amber, green, red, blue, white, and yellow Screw terminal and solder/tab terminal available Degree of protection: The current-limiting resistor in the LED lamp eliminates the need for external resistors Lens AL6➁-L Marking Plate AL6➁-W Lens Holder Gasket LED lamp Specifications Illumination Operating Voltage Lens Color Code Built-in LED Lamp LED 6V AC/DC, 2V AC/DC, 24V AC/DC A (amber), G (green), R (red), S (blue), W (white), Y (yellow) LSTD LED Lamp LSTD-6➁ LSTD-➁ LSTD-2➁ Rated Voltage 6V AC/DC 2V AC/DC 24V AC/DC A, R, W G, S, PW A, G, R, PW, S, W Current Draw AC 8 ma 8 ma ma 0 ma DC 7 ma 5.5 ma 0 ma ma LED Lamp Color Code Operating Temperature Operating Humidity Insulation Resistance Dielectric Strength Terminal Style Housing Material A (amber), G (green), PW (pure white), R (red), S (blue), W (white) 20 C to +50 C (no freezing) 45 to 85% RH (no condensation) Between live and dead metal parts: 00mΩ minimum (500V DC megger) Between live and dead metal parts: 2000V AC, minute Screw terminal: M2.6 Tab terminal: #0 solder/tab terminal (applicable cable:.25 mm 2 max.) Black plastic Degree of Protection (waterproof/oiltight) (according to IEC 6052) Weight (approx.) Terminal screw type: 8g Solder/tab screw type: g Types Round Square Rectangular Shape Terminal Style Operating Voltage Rectangular with 3-sided Barrier Solder/Tab Terminal Screw Terminal Solder/Tab Terminal Screw Terminal Solder/Tab Terminal Screw Terminal Solder/Tab Terminal Screw Terminal (Ordering ) AP6MS52➁ Lens Color Code Built-in LED () LSTD-6➁ 6V AC/DC±5% 2V AC/DC±0% AP6MS53➁ LSTD-➁ 24V AC/DC±0% AP6MS54➁ LSTD-2➁ 6V AC/DC±5% AP6MS52M➁ LSTD-6➁ 2V AC/DC±0% AP6MS53M➁ LSTD-➁ 24V AC/DC±0% AP6MS54M➁ LSTD-2➁ 6V AC/DC±5% AP6QS52➁ LSTD-6➁ 2V AC/DC±0% AP6QS53➁ LSTD-➁ 24V AC/DC±0% AP6QS54➁ Specify a lens color LSTD-2➁ 6V AC/DC±5% AP6QS52M➁ code in place of ➁ in LSTD-6➁ the 2V AC/DC±0% AP6QS53M➁ LSTD-➁ 24V AC/DC±0% AP6QS54M➁ A: amber LSTD-2➁ 6V AC/DC±5% AP6HS52➁ R: red LSTD-6➁ 2V AC/DC±0% AP6HS53➁ S: blue LSTD-➁ 24V AC/DC±0% AP6HS54➁ Y: yellow LSTD-2➁ 6V AC/DC±5% AP6HS52M➁ LSTD-6➁ 2V AC/DC±0% AP6HS53M➁ LSTD-➁ 24V AC/DC±0% AP6HS54M➁ LSTD-2➁ 6V AC/DC±5% AP6GS52➁ LSTD-6➁ 2V AC/DC±0% AP6GS53➁ LSTD-➁ 24V AC/DC±0% AP6GS54➁ LSTD-2➁ 6V AC/DC±5% AP6GS52M➁ LSTD-6➁ 2V AC/DC±0% AP6GS53M➁ LSTD-➁ 24V AC/DC±0% AP6GS54M➁ LSTD-2➁

12 ø6 AP6S Series Miniature Pilot Lights Dimensions Screw Terminal () Hex Nut 8 () 24 () 24 () Panel Thickness 0.8 to 4 Gasket Hex Nut M2.6 Terminal Screw 0 2. ø7.8 ø Round 6 Square Rectangular Rectangular (3-sided Barrier) M2.6 Terminal Screw Solder/Tab Screw Terminal () 8 () 24 () 24 () Panel Thickness 0.8 to 6 Gasket 3.8 ø7.8 ø X X2 Round 6 Square Rectangular Rectangular (3-sided Barrier) Locking Ring (plastic) #0 Solder/Tab Terminal Width t Mounting Hole Layout All dimensions in mm. ø6.2 A B Minimum Mounting Centers A Round/Square Rectangular Round/Square Rectangular Screw Terminal 23 mm 23 mm 23 mm 24 mm Tab Terminal 8 mm 8 mm 8 mm 24 mm B Terminal Arrangement (Bottom View) Screw Terminal Solder/Tab Terminal Lamp Terminal (X) X Lamp Terminal (X) X2 X2 Lamp Terminal (X2) Lamp Terminal (X2) 2

13 AP6S Series Miniature Pilot Lights ø6 Accessories Tools Locking Ring Wrench Shape Specification 60 ø8 Metal (nickel-plated brass) Ordering MT-00 MT-00 Remarks Used to tighten the locking ring when installing an AP6S unit onto a panel. Lamp Holder Tool ø.6 5 ø4 Rubber OR-55 OR-55 Used to install and remove LED lamps. Lens Removal Tool Stainless Steel MT-0 MT-0 Used to remove lens and buttons. 60 Replacement Parts for AP6M/AP2M/APM Lens Marking Plate Shape Ordering Round AL6M-L➁ AL6M-L➁PN05 5 Square AL6Q-L➁ AL6Q-L➁PN05 5 Rectangular Rectangular with 3-sided Barrier AL6H-L➁ AL6H-L➁PN05 5 Round AL6M-W AL6M-WPN05 5 Remarks Specify a color code in place of ➁ in the Ordering A: amber C: clear R: red S: blue Y: yellow Use a clear lens for white illumination. Square AL6Q-W AL6Q-WPN05 5 Rectangular Rectangular with 3-sided Barrier AL6H-W AL6H-WPN05 5 LED Lamps Operating Voltage 6V DC ±0% Current Draw AC DC 7 ma 8 ma (A, R, W) 5.5 ma LSTD-6➁ (G, PW, S) 2V AC/DC ±0% ma 0 ma LSTD-➁ 24V AC/DC ±0% ma 0 ma LSTD-2➁ Ordering ➁Illumination Color Code LSTD-6➁ LSTD-6➁PN0 Specify a color code in place of ➁ in the Ordering 0 A: amber LSTD-➁ PW: pure white LSTD-➁PN0 R: red 0 S: blue LSTD-2➁ LSTD-2➁PN0 Use a pure white (PW) LED lamp with yellow (Y) lens. 0 Base BAS/3 3

14 ø6 AP6S Series Miniature Pilot Lights Safety Precautions Turn off power to the AP6S series units before installation, removal, wiring, maintenance, and inspection. Failure to turn power rent requirements. Improper soldering may cause overheating and For wiring, use wires of proper size to meet the voltage and cur- off may cause electrical shocks or fire hazard. create fire hazards. Instructions Replacing Lens and Marking Plate Removal Remove the operator (color lens, marking plate, and lens holder) by holding the color lens recesses with the Lens Removal Tool (MT-0) and pulling it out. Remove the marking plate by disengaging the latches between the color lens and lens holder. The marking plate must be engraved on the front side as shown below. Grooves Color Lens (polyarylate) Fitting Grooves Engrraving Surface Marking Plate (acryl) Waterproof Gasket (silicon rubber) Lens Holder (polyarylate) Installation Place the marking plate on the lens holder in the correct direction and press the color lens onto the lens holder to engage the latches. Insert the lens holder into the housing in the correct direction. Marking Plate and Engraving Area Engraving must be made on the engraving area less than 0.5mm deep. Shape Size Engraving Area Round ø3.8 mm ø2 mm Square 3.8 mm 2 mm Rectangular mm 2 8 mm Tab Terminal The locking ring is plastic. To tighten the ring, use an optional locking ring wrench (MT-00). Do not use pliers. Do not tighten with excessive force, otherwise the locking ring will be damaged. Tightening torque should not exceed 0.88 N m Collective Mounting and Continous Illumination Collective mounting or continuous illumination of pilot lights may cause the ambient temperature to rise above the rated operating temperature. Make sure to provide efficient ventilation when the mounting panel is not metallic or when the pilot lights are mounted collectively. Wiring Solder the terminal at 350 C within 3 seconds using a 60W soldering iron. SnAgCu type lead-free solder is recommended. When soldering, do not touch the pilot light housing with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. Power Supply for LED Lamps The operating voltage of the LED lamp is within ±5% or ±0% of the rated voltage. Make sure that the power voltage is within this range. Notes on Mounting Screw Terminal Because screw terminal types use hexagonal nuts, they cannot be mounted closely together. However, rectangular units can be mounted closely when installed horizontally. When removing the hexagonal nuts, loosen the the terminal screws. The hexagonal nuts cannot be removed when the terminal screws are tightened. When mounting the pilot lights collectively, note the mounting order. Pilot lights mounted in between units cannot be removed. 4

15 AP6S Series Miniature Pilot Lights ø6 Transformer Separate Mounting Type Primary Voltage Secondary Voltage (Ordering ) Applicable LED Lamp For 24V 00/0V AC 24V AC, 0.5W TWR52 200/220V AC 24V AC, 0.5W TWR522 LSTD-2➁ 400/440V AC 24V AC, 0.5W TWR542 A dust cover is supplied with the separate mounting type transformer. Connect only one LSTD LED lamp to the separate mounting type transformer. Use plastic mounting clip BCZ-E/NS35N when mounting 400/440V voltage models. Specifications Operating Voltage 00/0V AC, 200/220V AC 400/440V AC (50/60 Hz) Power Consumption 2.4 VA Rated Insulation Voltage 600V Insulation Resistance 00 MΩ minimum (500V DC megger) Operating Temperature 30 to +60 C (no freezing) Relative Humidity 35 to 85% (no condensation) Vibration Resistance Operating extremes: 5 to 55 Hz, amplitude 0.5 mm Shock Resistance Damage limits:,000 m/s2 Dielectric Strength 2,500V AC, minute Terminal Style M3.5 Applicable Wire 2 mm 2 maximum, 2 wires maximum Dimensions M3.5 Terminal Screw Secondary Side Mounting Hole 2 ø3.3 Terminal Screw Primary Side Accessories Description Appearance Description Ordering DIN Rail Aluminum Weight: Approx. 200g Length: m Steel Weight: Approx. 320g Length: m BAA000 BAP000 BAA000PN0 BAP000PN0 Mounting Clip Steel Weight: Approx.5g Plastic Weight: Approx.5g BNL6 BCZ-E/NS35N BNL6PN0 BCZ-E/NS35NPN0 0 Use plastic mounting clip BCZ/NS35N when using 400/440V AC voltage transformers. 5

16 ø Available in Various Sizes Five illumination colors: amber, green, red, white, yellow Various sizes and design. Available with a built-in current limiting resistor. Waterproof () types available for ø and ø0. Panel thickness 0.6 to 4 mm (built-in current limiting resistor type 0.6 to 6 mm) Specifications Without a Built-in Current Limiting Resistor Color Code Rated Current UP Series Miniature Pilot Lights A (amber), G (Green), Red (R), W (white), Y (yellow) 0 ma (Amber, Green, Red, Yellow) 5 ma () Forward Current 20 ma maximum at 25 C Reverse Voltage 3V maximum at 25 C Power Consumption 60 mw maximum at 25 C Operating Temperature Storage Temperature Forward Voltage Dielectric Strength 20 to +55 C 25 to +80 C Maximum value: 3V Standard value: 2V (forward current: 0 ma) Between live and dead parts: 500V AC, minute ø0 UP ø0. ø7 UP7 ø UP ø. ø6 UP06 ø8 UP8 ø With a Built-in Current Limiting Resistor A (amber), G (Green), Red (R), W (white), Color Code Y (yellow) Operating Voltage Rated Current Operating Temperature Operating Humidity Dielectric Strength 2V DC±0%, 24V DC±0% 5 ma 20 to +55 C (no freezing) 45 to 85% RH (no condensation) Between live and dead parts: 500V AC, minute ø7. Weight (example) Weight (approx.) ø g (UP06-67) 5g (UP7-277) 6g (UP8-2487) 7g (UP-247) 8g (UP-247) UP Series Shape Shroud Operating Voltage Degree of Protection UP-7➁ UPP-7➁ Ordering UP-7➁ Color Code M0 P.0 (+) Terminal Dimensions (mm) UP-7➁PN0 0 UPP-7➁ UPP-7➁PN ø Shroud (with resistor) 2V DC ±0% 24V DC ±0% UP-27➁ Specify a color UP-27➁ code in place of M0 P0.75 Panel Thickness 0.6 to 6 UP-27➁PN0 0 ➁ in the UPP-27➁ UPP-27➁ UPP-27➁PN0 A: amber 0 UP-247➁ UP-247➁ UP-247➁PN0 R: red 2 0 UPP-247➁ UPP-247➁ 26.3 Y: yellow Paint (+) UPP-247➁PN0 0 UP-8➁ UPP-8➁ ø8 M0 UP-8➁ P.0 (+) Terminal UP-8➁PN0 0 UPP-8➁ UPP-8➁PN ø2 ø Note: For UP series pilot lights without built-in current limiting resistors, connect an external resistor in series. Otherwise, the LED may be damaged. 6

17 UP Series Miniature Pilot Lights ø UP Series Shape (with resistor) Deep Shroud Operating Voltage 2V DC ±0% 24V DC ±0% Degree of Protection Ordering UP-28➁ Color Code Dimensions (mm) UP-28➁ M0 P0.75 Panel Thickness 0.6 to 6 UP-28➁PN0 0 UPP-28➁ UPP-28➁ UPP-28➁PN0 0 UP-248➁ UP-248➁ 2 UP-248➁PN UPP-248➁ UPP-248➁ Paint (+) UPP-248➁PN0 0 Specify a color UP-➁ code in place of M0 P.0 UP-➁ ➁ in the (+) Terminal UP-➁PN0 A: amber 0 UP-➁ R: red UPP-➁ 2.8 UP-➁PN0 Y: yellow ø8 7 ø2 3.8 ø. ø2 3.8 Deep Shroud (with resistor) UP Series Shroud Shape 2V DC ±0% 24V DC ±0% Operating Voltage Degree of Protection UP-2➁ UP-2➁ M0 P0.75 Panel Thickness 0.6 to 6 UP-2➁PN0 0 UPP-2➁ UPP-2➁ UPP-2➁PN0 0 UP-24➁ UP-24➁ 2 UP-24➁PN UPP-24➁ UPP-24➁ Paint (+) UPP-24➁PN0 0 Note: For UP series pilot lights without built-in current limiting resistors, connect an external resistor in series. Otherwise, the LED may be damaged. UP-7➁ UPP-7➁ Ordering UP-7➁ Color Code ø8 (+) Terminal M P0.75 ø0 ø2 3.8 Dimensions (mm) UP-7➁PN0 0 UPP-7➁ UPP-7➁PN0 0 7 ø 2.7 Shroud (with resistor) 2V DC ±0% 24V DC ±0% UP-27➁ UP-27➁ M P0.75 Panel Thickness 0.6 to 6 UP-27➁PN0 0 UPP-27➁ UPP-27➁ UPP-27➁PN0 0 UP-247➁ UP-247➁ UP-247➁PN UPP-247➁ UPP-247➁ Paint (+) UPP-247➁PN0 0 UP-8➁ code in place of Specify a color M P0.75 UP-8➁ ➁ in the (+) Terminal UP-8➁PN0 UPP-8➁ A: amber R: red 0 UPP-8➁ 2 UPP-8➁PN0 Y: yellow ø8 7 ø ø (with resistor) Deep Shroud 2V DC ±0% 24V DC ±0% UP-28➁ UP-28➁ M P0.75 Panel Thickness 0.6 to 6 UP-28➁PN0 0 UPP-28➁ UPP-28➁ UPP-28➁PN0 0 UP-248➁ UP-248➁ 2 UP-248➁PN UPP-248➁ UPP-248➁ Paint (+) 2 5 UPP-248➁PN0 0 UP-➁ UPP-➁ ø8 UP-➁ M P0.75 (+) Terminal UP-➁PN0 0 UPP-➁ UPP-➁PN0 0 ø 2.7 ø ø8.8 5 Note: For UP series pilot lights without built-in current limiting resistors, connect an external resistor in series. Otherwise, the LED may be damaged. 7

18 ø UP Series Miniature Pilot Lights UP Series Shape Deep Shroud (with resistor) Operating Voltage 2V DC ±0% 24V DC ±0% Degree of Protection Ordering UP-2➁ Color Code Dimensions (mm) UP-2➁ Specify a color M P0.75 Panel Thickness 0.6 to 6 UP-2➁PN0 code in place of 0 ➁ in the UPP-2➁ UPP-2➁ UPP-2➁PN0 0 A: amber UP-24➁ UP-24➁ 2 UP-24➁PN0 R: red UPP-24➁ UPP-24➁ Paint (+) UPP-24➁PN0 Y: yellow 0 Note: For UP series pilot lights without built-in current limiting resistors, connect an external resistor in series. Otherwise, the LED may be damaged. ø8 ø ø 2.7 UP8 Series Shroud Shape Operating Voltage Degree of Protection Ordering UP8-87➁ Color Code (+) Terminal M8 P0.75 Dimensions (mm) ø0 UP8-87➁ UP8-87➁PN Shroud (with resistor) 2V DC ±0% UP8-287➁ UP8-287➁ M8 P0.75 Panel Thickness 0.6 to 6 ø7 ø0 UP8-287➁PN0 0 24V DC ±0% UP8-2487➁ UP8-2487➁ UP8-2487➁PN0 Paint (+) M8 P0.75 UP8-88➁ (+) Terminal ø0 (with resistor) Deep Shroud 2V DC ±0% 24V DC ±0% UP8-88➁ UP8-288➁ UP8-2488➁ Specify a color UP8-88➁PN0 code in place of ➁ in the.5 0 UP8-288➁ UP8-288➁PN0 A: amber R: red Y: yellow M8 P0.75 Panel Thickness 0.6 to 6 0 ø7 UP8-2488➁ 2 23 Paint (+) UP8-2488➁PN0 0 UP8-8➁ (+) Terminal 6. M8 P ø0 ø ø0 UP8-8➁ UP8-8➁PN Deep Shroud (with resistor) 2V DC ±0% UP8-28➁ UP8-28➁ M8 P0.75 Panel Thickness 0.6 to 6 ø7 ø7. ø0 UP8-28➁PN0 0 24V DC ±0% UP8-248➁ UP8-248➁ UP8-248➁PN0 Paint (+) Note: For UP series pilot lights without built-in current limiting resistors, connect an external resistor in series. Otherwise, the LED may be damaged. 8

19 UP Series Miniature Pilot Lights ø UP7 Series Shroud Shape Operating Voltage Degree of Protection Ordering UP7-77➁ Color Code (+) Terminal M7 P0.75 Dimensions ø UP7-77➁ UP7-77➁PN Shroud (with resistor) 2V DC ±0% 24V DC ±0% UP7-277➁ UP7-2477➁ M7 P0.75 UP7-277➁ ø6 ø UP7-277➁PN0 0 UP7-2477➁ Paint (+) 2.8 Panel Thickness 0.6 to 6 UP7-2477➁PN (+) Terminal M7 P0.75 UP7-78➁ ø (with resistor) Deep Shroud 2V DC ±0% 24V DC ±0% UP7-78➁ UP7-278➁ UP7-2478➁ UP7-7➁ Specify a color code in place of ➁ 6.8 UP7-78➁PN0 in the UP7-278➁ UP7-278➁PN0 A: amber Y: yellow M7 P0.75 Panel Thickness 0.6 to 6 R: red 0 UP7-2478➁ 2 ø6 UP7-2478➁PN0 Paint (+) UP7-7➁ UP7-7➁PN (+) Terminal 4.6 M7 P ø ø6. ø 0.4 Deep Shroud (with resistor) 2V DC ±0% 24V DC ±0% UP7-27➁ UP7-247➁ UP7-27➁ UP7-27➁PN0 0 UP7-247➁ 2 M7 P0.75 ø6 ø7 ø UP7-247➁PN0 Paint (+) Panel Thickness 0.6 to Note: For UP series pilot lights without built-in current limiting resistors, connect an external resistor in series. Otherwise, the LED may be damaged. UP06 Series Shroud Shape Operating Voltage Degree of Protection Ordering UP06-67➁ Color Code M6 P0.75 (+) Terminal Dimensions ø7.5 Deep Shroud UP06-67➁ UP06-68➁ UP06-6➁ UP06-67➁PN0.8 0 Specify a color code in place of ➁ M6 in the P0.75 UP06-68➁ (+) Terminal A: amber R: red 7 UP06-68➁PN Y: yellow UP06-6➁ (+) Terminal UP06-6➁PN M6 P ø ø6 ø Note: For UP series pilot lights without built-in current limiting resistors, connect an external resistor in series. Otherwise, the LED may be damaged.

20 ø UP Series Miniature Pilot Lights Instructions Polarity Pay attention to the polarity of the power supply as UP series units do not contain a diode for protection against reverse polarity. On solder terminal units, the terminal with a white paint marking is positive. On wire-wrap terminal units, the long terminal is positive and the short terminal is negative. Solder Terminal Paint Marking Wire-Wrap Terminal Negative Terminal Current Limiting Resistor When using a UP series unit without a built-in current limiting resistor, connect an external current limiting resistor. Calculate the resistance using the following formula. Positive Side Current Limiting Resistor Terminal (plastic) Positive Lamp Terminal Negative Lamp Terminal Negative Side Wiring Solder the terminal at 350 C within 3 seconds using a 60W soldering iron. SnAgCu type lead-free solder is recommended. When soldering, do not touch the pilot light housing with the terminal. Do not bend the terminal or apply excessive force to the terminal. Notes on Operating Voltage The rated operating voltage represents a complete DC value. When using a pulsating voltage such as a full-wave reticification voltage, keep peak currents within the forward current If. Peak currents exceeding If may shorten the life of the LED lamp. Panel Mounting When mounting UP series units on to the panel, refer to the table below for the recommended tightening torque. Do not tighten with excessive force, otherwise the locking ring will be damaged. Type UP06 UP7 UP8 UP UPP UP UPP Recommended Tightening Torque 0.2 N m 0.3 N m 0.4 N m 0.5 N m 0.2 N m 0.5 N m 0.2 N m Resistance (R) = Operating Voltage V F I F Reference Value of Current Limit Resistor Amber, Green, Red, Yellow 5V DC 300Ω (/4W) 200Ω (/4W) 6V DC 30Ω (/4W) 270Ω (/4W) 2V DC 000Ω (/4W) 680Ω (/4W) 24V DC 2200Ω (/2W) 500Ω (/2W) Waterproof Type The degree of protection is distinguished by the color of the terminal. Terminal (Plastic) Degree of Protection Black (standard) Blue (waterproof) 20

21 UP Series Miniature Pilot Lights (Single Board Mounting Type) Single board mounting for miniature LEDs. Same length as H6, L6, and LW series control units Five illumination colors: amber, green, red, white, yellow Specifications Rated Current 0 ma (Amber, Green, Red, Yellow) 5 ma () Forward Current 20 ma maximum at 25 C Reverse Voltage 3V maximum at 25 C Power Consumption 60 mw maximum at 25 C Operating Temperature 20 to +55 C (no freezing) Storage Temperature 25 to +80 C (no freezing) Maximum value: 3V Forward Voltage Standard value: 2V (forward current: 0 ma) Dielectric Strength Between live and dead parts: 500V AC, minute Weight (approx.) 6g (UP8-8V) ø8 ø ø0 UP8 / UPP / UPP Mounting Hole Size Shape Degree of Protection Ordering Color Code ø8 UP8 Deep shroud UP8-8V➁ UP8-8V➁PN0 A: amber 0 ø UP Deep shroud (waterproof) UPP-V➁ UPP-V➁PN0 R: red 0 ø0 UPP Deep shroud (waterproof) UPP-V➁ UPP-V➁PN0 Y: yellow 0 Specify a color code in place of ➁ in the Note: Connect an external current limiting resistor in series. Otherwise, the LED may be damaged. Dimensions P0.75 M8 Panel Thickness: 0.6 to 6 UP8-8V 2 3 ø (+) Terminal ø0.6 + Marking Body.6 ø8..5 ø7 ø0 ø5 LED Kit 38.8 When installed When installed 44.2 P0.75 M UP-V ø ø8.8 P M0 UPP-V ø0 ø All dimensions in mm. PC Board Mounting Hole Panel Cut-out Internal Circuit.27 ø0.8 ø8. ±0. ø. ±0. ø0. ±0. Positive Terminal Negative Terminal The longer pin is the positive terminal 2

22 ø UP Series Miniature Pilot Lights Single Board Mounting UP series miniature pilot light single board mounting types can be mounted with H6, L6, LW series control units on the same panel. Follow the instructions below on single board mounting. LED Kit UP Unit. Mount the LED kit to the PC board. Temporary mounting A PC Board (t=.6mm) Insert terminal 45 minimum Bend terminal. Note the polarity of the terminals and insert the terminals to the PC board. 2. Make sure that part A of the LED kit is pressed tightly to the PC board. Bend the terminals sideways as shown on the left. 2. Mount the operator and the UP series pilot lights on to the control panel. UP Unit Panel Operator 3. Mount the contact block to the operator of the miniature control unit and lock the unit by turning the locking lever. Contact Block 4. Install the PC board in. to the panel in mm Locking Lever Note: Make sure that the LED kit is inserted into the UP series unit. 5. Solder the terminals. Before soldering, make sure that each terminal of the contact block is securely inserted into the PC board holes. * When mounting H6, L6, LW, and UP series on a single board, make sure that the distance between the front of the panel and the mounting side of the PC board is 37.6 mm. Safety Precautions Instructions Polarity Pay attention to the polarity of the power supply as UP series units do not contain a diode for protection against reverse polarity. The long terminal is positive and the short terminal is negative. Current Limiting Resistor When using a UP series unit without a built-in current limiting resistor, connect an external current limiting resistor. Calculate the resistance using the following formula. LED Current Limiting Resistor + (R) Operating Voltage (V) Operating Voltage (V) 2 Resistance (R) = Rated Current (I) * * Rated Current (I) = 0 ma, except white color at 5 ma Note: Use a resistor of higher resistance than the calculated value (R). Rated Wattage of Resistor (W) Rated Current Operating = 2 to 3 * (I) Voltage (V) * 2 to 3 is a safety factor Current Limiting Resistor Reference Value Color Amber, Green, Operating Voltage Yellow, Amber 5V DC 300Ω (/4W) 200Ω (/4W) 6V DC 30Ω (/4W) 270Ω (/4W) 2V DC 000Ω (/4W) 680Ω (/4W) 24V DC 2200Ω (/2W) 500Ω (/2W) Wiring Solder the terminal at 350 C within 3 seconds using a 60W soldering iron. SnAgCu type lead-free solder is recommended. When soldering, do not touch the pilot light housing with the terminal. Do not bend the terminal or apply excessive force to the terminal. Notes on Panel Mounting Use an optional locking ring wrench to mount the unit onto a panel. Tightening torque should not exceed 0.5 N m. Do not use pliers. Do not tighten with excessive force, otherwise the locking ring will be damaged. PC Board and Circuit Design Use glass epoxy copper clad laminate, double-sided through-hole PC boards with a thickness of.6 mm. Turn off power to the unit before installation, removal, wiring, maintenance, and inspection. Failure to turn off may cause electrical shocks or fire hazard. For wiring, use wires of a proper size to meet the voltage and current requirements. Improper soldering or failure to tighten the terminal screw may cause overheating and fire. Example of single board mounting 22

23 UZ6 Series Miniature Buzzer ø6 Miniature Electronic Buzzer for mounting in ø6 mm Mounting Hole Same size and terminal alignment as AP6M series miniature pilot lights. Sounds can be adjusted from approximately 30 to 600 cycles per minute using the optional sound adapter. The sound adapter can be snapped on to the rear part of the buzzer unit. Cyclical Sound Adapter Types Buzzer Unit (continuous sound) Shape Terminal Style Operating Voltage Buzzer Unit (Operating ) Solder 2V DC ±0% UZ6-24V DC ±0% UZ6-2 Cyclical Sound Adapter Shape Terminal Style Operating Voltage (Operating ) Screw 2V/24V DC ±0% UZ6-F0 Accessories Shape Locking Ring Wrench Removal Tool Specification Nickel-plated brass Stainless steel (Ordering ) MT-00 MT-00 Remarks Used to tighten the locking ring when installing a UZ6 buzzer onto a panel. Tighten the locking ring to a torque of 0.88 N m maximum. Used to remove the cyclical sound adapter from the buzzer. The cyclical sound adapter can be removed by using the tip of the tool as shown in the left photo to 5 ø8 6 Terminal Cover For cyclical sound adapter AP-VL Specifications Buzzer Unit Ratings / Cyclical Sound Adapter Insulation Voltage 60V DC Operating Voltage 2V DC ±0%, 24V DC ±0% Current Draw 24 ma Sound Pressure (at 0.m) Steady sound: 75dB (at the rated voltage) Sound Frequency 3.5 khz ±800Hz Operating Temperature 20 to +50 C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Insulation Resistance 00 MΩ minimum (500V DC megger) Dielectric Strength Between live and dead parts:,000v AC, minute Degree of Protection (enclosed type) Terminal Style Solder terminal Applicable Wire ø or 0.75 mm 2 max. Cap Color Blue Weight (approx.) 6.5g LA3Z (ø6) buzzer units also available. See catalog for the L6 series Control Units. Operating Voltage 2/24V DC ±0% Current Draw 30 ma (when installed on the buzzer unit) 30 to 600 cycles per minute Cyclical Sound (period: 2 to 0. sec) ON/OFF time ratio : Applicable Buzzer Unit 2V DC, 24V DC buzzers (UZ6-, UZ6-2) Terminal Screw M3 Applicable Wire.25 mm 2 max. Weight (approx.) 3.5g 23

24 UZ6 Series Miniature Buzzer ø6 Dimensions Buzzer Unit Cyclical Sound Adapter Panel Cut-out Panel Thickness 0.8 to 6mm Side + 0.4t ø5.6 Terminal Cover AP-VL3 X Terminal Cover : AP-VL3 (Optional) +0.2 ø ø ø.2 X Negative Terminal M3 Terminal Screw Instructions Notes on Panel Mounting Use an optional locking ring wrench to mount the unit onto a panel. Tightening torque should not exceed 0.88 N m. Do not use pliers. Do not tighten with excessive force, otherwise the locking ring will be damaged. Power Supply Noise When the buzzer is used where power noise might occur, use a noise suppressor element to prevent noise interference. Cyclical Sound Adjustment Pierce the round mark on the nameplate on top of the cyclical sound adapter with a flat screwdriver and adjust the variable resistor inside. Turn clockwise for longer cyclical sounds and counterclockwise for shorter cyclical sounds. Notes on Installing the Cyclical Sound Adapter. The cyclical sound adapter can be used on 2V and 24V DC buzzer units (UZ6-, UZ6-2). 2. Mount the buzzer unit on the panel before installing the cyclical sound adapter on the panel. The buzzer unit cannot be mounted with the cyclical sound adapter installed. 3. When installing the cyclical sound adapter, make sure that the marking on the cyclical sound adapter is on the same side as the marking on the buzzer unit and press in. X2 Negative Terminal Marking Marking Negative Terminal Nameplate X Note: When wiring, do not apply exessive force to X and X2 terminals. Wiring Solder the terminal at 350 C within 3 seconds using a 60W soldering iron. SnAgCu type lead-free solder is recommended. When soldering, do not touch the buzzer unit housing with the terminal. Do not bend the terminal or apply excessive force to the terminal. Safety Precautions Turn off power to the buzzer before installation, removal, wiring, maintenance, and inspection. Failure to turn off may cause electrical shocks or fire hazard. For wiring, use wires of a proper size to meet the voltage and current requirements. Tighten the M3 screw terminal of the cyclical sound adapter to a torque of 0.6 to.0 N m. Improper soldering or failure to tighten the terminal screw may cause overheating and fire. Specifications and other descriptions in this catalog are subject to change without notice. IDEC CORPORATION (USA) 75 Elko Drive, Sunnyvale, CA 408-0, USA Tel: / (800) 6-IDEC (433) Fax: / (800) opencontact@idec.com IDEC CANADA LIMITED Unit -5, Brunel Road, Mississauga, Ontario, L4Z X3, Canada Tel: , Toll Free: (888) Fax: sales@ca.idec.com IDEC AUSTRALIA PTY. LTD. /3 Macro Court, Rowville, Victoria 378, Australia Tel: , Toll Free: Fax: sales@au.idec.com IDEC ELECTRONICS LIMITED Unit, Beechwood, Chineham Business Park, Basingstoke, Hampshire RG4 8WA, UK Tel: , Fax: sales@uk.idec.com 7-3, Nishi-Miyahara -Chome, Yodogawa-ku, Osaka , Japan Tel: , Fax: products@idec.co.jp IDEC ELEKTROTECHNIK GmbH Wendenstrasse 33, 0537 Hamburg, Germany Tel: , Fax: service@idec.de IDEC (SHANGHAI) CORPORATION Room , 6F, Gangtai Plaza, No. 700, Yan'an East Road, Shanghai 0000, PRC Tel: , Fax: idec@cn.idec.com IDEC (BEIJING) CORPORATION Room B, Tower B, The Grand Pacific Building, 8A Guanghua Road, Chaoyang District, Beijing 0006, PRC Tel: , Fax: IDEC (SHENZHEN) CORPORATION Unit AB-3B, Tian Xiang Building, Tian an Cyber Park, Fu Tian District, Shenzhen, Guang Dong 58040, PRC Tel: , Fax: IDEC IZUMI (H.K.) CO., LTD. Unit , DCH Commercial Centre No. 5, Westlands Road, Quarry Bay, Hong Kong Tel: , Fax: info@hk.idec.com IDEC TAIWAN CORPORATION 8F-, No. 7, Hsin Tai Wu Road, Sec., Hsi-Chih, Taipei County, Taiwan Tel: , Fax: service@tw.idec.com IDEC IZUMI ASIA PTE. LTD. No. 3, Tannery Lane #05-0, Dragon Land Building, Singapore Tel: , Fax: info@sg.idec.com Cat. No. EP76-0 MARCH DNP PRINTED IN JAPAN

AP/UP Series Miniature Pilot Lights UZ Series Miniature Buzzer

AP/UP Series Miniature Pilot Lights UZ Series Miniature Buzzer AP/UP Series Miniature Pilot Lights UZ Series Miniature Buzzer Pilot Lights / Buzzer Selection Guide Series AP Series Miniature Pilot Lights AP6S Series Miniature Pilot Lights Mounting Hole Size ø6 ø2

More information

HS6B Subminiature Interlock Switches

HS6B Subminiature Interlock Switches World-class compactness with three poles of contacts. World s smallest switch: 30 30 78 mm Dual contacts and monitor contacts achieve the highest safety category (ISO 13849-1, EN 954-1) Two actuator entry

More information

Bright illumination face and snap-action switching.

Bright illumination face and snap-action switching. ø A2 Series ø10 A1 Series ø8 A8 Series A2 Series A1 Series A8 Series Bright illumination face and snap-action switching. See website for details on approvals and standards. Hole Size Model Function Degree

More information

ø22mm XW Series Emergency Stop Switches (Mechanical Indicator) Smooth Button Delivers Style and Cleanliness

ø22mm XW Series Emergency Stop Switches (Mechanical Indicator) Smooth Button Delivers Style and Cleanliness ø22mm XW Series Emergency Stop Switches (Mechanical Indicator) Normal/latched status can be checked from a distance with the mechanical indicator function. The smooth ridgeless button prevents dust build-up

More information

ø10 A1 Series Miniature Control Units

ø10 A1 Series Miniature Control Units A1 ø10 A1 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals

More information

ø8 A8 Series Miniature Control Units

ø8 A8 Series Miniature Control Units A8 ø8 A8 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals

More information

ø12 A2 Series Miniature Control Units

ø12 A2 Series Miniature Control Units ø2 A2 Series Miniature Control Short 22-mm-long body miniature control unit series with bright LED illumination face and snap-action switching. Degree of protection: IP40 and IP5 (IEC 0529) All series

More information

ø16mm X6 Series Emergency Stop Switches Excellent safety and design. The shortest depth behind the panel in its class.

ø16mm X6 Series Emergency Stop Switches Excellent safety and design. The shortest depth behind the panel in its class. mm X6 Series Emergency Stop Switches Excellent safety and design. The shortest depth behind the panel in its class. Actual Size Tab terminal can be wired easily using quick connects. Third-generation Reverse

More information

Illuminated buzzer for elevators, robots and production sites

Illuminated buzzer for elevators, robots and production sites ø22mm HW1Z Illuminated Buzzer Illuminated buzzer for elevators, robots and production sites Combination buzzer and pilot light Alerts workers of danger with sound and light Waterproof construction HW1Z

More information

UP Series Miniature Pilot Lights

UP Series Miniature Pilot Lights Available in Various Sizes Five illumination colors: amber, green, red, white, yellow Various sizes and design. Available with a built-in current limiting resistor. Waterproof () types available for and.

More information

LD6A. LED SignaLight Towers. Clear, audible alarm sound. Warning/caution indicated by flashing light. Complies with IEC Standards (IEC60073)

LD6A. LED SignaLight Towers. Clear, audible alarm sound. Warning/caution indicated by flashing light. Complies with IEC Standards (IEC60073) LD6A LED SignaLight Towers Steady/Flashing/Alarm Warning/caution indicated by flashing light Complies with IEC Standards (IEC073) Clear, audible alarm sound 3.3 khz 70 to 90 db 2 3 4 5 LD6A LED SignaLight

More information

MC SERIES. Illuminated Control Units. Super LED or Incandescent Illumination Removable Contact Blocks

MC SERIES. Illuminated Control Units. Super LED or Incandescent Illumination Removable Contact Blocks MC SERIES Illuminated Control Units Super LED or Incandescent Illumination Removable Contact Blocks MC SERIES ILLUMINATED CONTROL UNITS Super Bright LED or Incandescent Illumination New Rectangular- and

More information

LW Silhouette Series. Illuminated Key Selector Switches Pushbuttons and Illuminated Pushbuttons with Round Guard. LW Silhouette Switches

LW Silhouette Series. Illuminated Key Selector Switches Pushbuttons and Illuminated Pushbuttons with Round Guard. LW Silhouette Switches W Silhouette Series Illuminated Key Selector Switches Pushbuttons and Illuminated Pushbuttons with ound Guard W Silhouette Switches W Silhouette Series Illuminated Key Selector Switches The two-way split

More information

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid 3000N locking strength (strongest* in class)! Suitable for large and heavy doors. Same actuators as HS1E (locking strength 3000N) can be used. Six contacts in a compact housing (same size as HS1E)! Same

More information

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid 3000N locking strength (largest in class)! * Suitable for large and heavy doors. Same actuators as HS1E (locking strength 3000N) can be used. *As of October 2009, according to IDEC research of plastic

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Non-Illuminated ushbuttons (Sub-Assembled) Contact Block + Operator + Button = Completed Unit art Numbers: Operators Style art Number Momentary Maintained LW1B-M0 LW1B-A0 LW2B-M0 LW2B-A0 Mushroom

More information

NC1V. Circuit Breakers

NC1V. Circuit Breakers 1V ircuit Breakers IDE's original Spring-up Terminals and over Provide IP20 Fingersafe Protection. 17.5 mm 3 mm 52.5 mm mm (1-pole) (2-pole) Auxiliary/alarm contact terminals are supplied with fingersafe

More information

Miniature Switches & Pilot Devices

Miniature Switches & Pilot Devices A8 Series Miniature Switches and Pilot Devices: 8mm Key features of the 21/64" (8mm) A8 series Switches and Pilot Devices include: 21/64" (8mm) round mounting hole Compact Design Saves Space Bright and

More information

Head Removal Detection Function for Safer Performance

Head Removal Detection Function for Safer Performance HS5D Miniature Interlock Switches Head Removal Detection Function for Safer Performance (00405) New Generation Miniature Interlock Switches IDEC s new unique Head Removal Detection Function is a new generation

More information

ø22mm LW Series Control Units

ø22mm LW Series Control Units ø22mm W Series ontrol Units ø22 W Series ontrol Units (Selection Guide) Function ategory ound Flush Square Flush Pushbutton ound Flush with Square Bezel Momentary/ ound Extended Square Extended W1B- 1

More information

IDEC E-Stop Switches. Simply Safe. Smart Products. Simple Solutions.

IDEC E-Stop Switches. Simply Safe. Smart Products. Simple Solutions. HW Switches In basic black or stylish metal, the HW series of mm switches from IDEC are available in several styles to dress up any panel. HW pushbuttons and pilot devices are internationally-rated, designed

More information

Think Automation and beyond... Focused brightness and visibility. IDEC LD6A LED Signalight Towers

Think Automation and beyond... Focused brightness and visibility. IDEC LD6A LED Signalight Towers Think Automation and beyond... Focused brightness and visibility IDEC LD6A LED Signalight Towers LD6A Signalight Towers Ergonomically designed for instant visual & audible recognition LD6A SignaLights

More information

LF1D/LF2D LED Illumination Units

LF1D/LF2D LED Illumination Units LF1D/LFD LED Illumination Units Wide-area lighting for improved target visibility. wide variety of sizes and light distribution angles. Durable and environmentally resistant LF1D-C LF1D-J LF1D-H LF1D-EH,

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

XA Series Emergency Stop Switches (w/removable Contact Block)

XA Series Emergency Stop Switches (w/removable Contact Block) XA ø6 XA Series Emergency Stop Switches (w/removable Contact Block) The World s First ø6 mm, 4-contact Emergency Stop Switch. Compact size - only 7.9 mm deep behind the panel. Reliable Safe break action.

More information

Signaling Lights LD6A. LD6A LED SignaLight Towers Assembled Products. Unique Striped Design Improves Visibility

Signaling Lights LD6A. LD6A LED SignaLight Towers Assembled Products. Unique Striped Design Improves Visibility Unique Striped Design Improves Visibility Key features of the LD6A LED SignaLight Towers include: The striped design with non-illuminated area between the lenses makes the illuminated color very visible.

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Emergency Stop Stations Part Numbers: Emergency Stop Stations Description Contacts Plastic Bezel Metal Bezel Ø 40mm Pushlock Turn Reset 1NO-1NC HW1X-BV411-R* HW4X-BV411-R* 2NC HW1X-BV402-R* HW4X-BV402-R*

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Switches & Pilot Devices HW Series 22mm IEC Style Global Pushbuttons Circuit Breakers Terminal Blocks Timers Relays & Sockets Display Lights Switches & Pilot Lights Key features include: Locking

More information

BA Series Terminal Blocks

BA Series Terminal Blocks Quick-mount terminal blocks for mounting on 35-mm-wide DIN rails. Current capacities from A to 00V (600V). Snaps on to 35-mm-wide DIN rails. Wide range of current capacities from A to 00A. Insulation voltage

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: Two button sizes: ø29 and ø4mm ead-free, ohs compliant, (EU directive 22/95/EC) Depth behind the panel: Standard - only 27.9mm for 1 to 4 contacts Unibody - only 23.9mm for 1NC or 2NC IDEC

More information

BA Series Terminal Blocks

BA Series Terminal Blocks Quick-mount terminal blocks for mounting on 35-mm-wide DIN rails. Current capacities from A to 400V (600V). Snaps on to 35-mm-wide DIN rails. Wide range of current capacities from A to 400A. Insulation

More information

A Series. Miniature Control Units

A Series. Miniature Control Units TEIH-ATM Electronic Auf der Bült 10-12 D 41189 Mönchengladbach Tel. 02166 958545 Fax 02166 958547 email: atm@treichl.de internet: A Series Miniature ontrol Units A Series Miniature ontrol Units Series

More information

LW Series offer flexibility in space-saving package

LW Series offer flexibility in space-saving package ourtesy of Steven Engineering, Inc. 230 yan Way, South San Francisco,, 94080-6370 Main Office: (650) 588-9200 Outside Local rea: (800) 258-9200 www.steveneng.com LW Series offer flexibility in space-saving

More information

ø22mm HW Series Control Units

ø22mm HW Series Control Units TREICHL-ATM Electronic Auf der Bült 10-12 D 41189 Mönchengladbach Tel. 02166 958545 Fax 02166 958547 email: atm@treichl.de internet: mm HW Series Control Units HW Series Control Units (Selection Guide)

More information

A series Switches & Pilot Lights

A series Switches & Pilot Lights A series Switches & Pilot ights ø16 ø12 ø10 ø8 A Series Selection Guide Series A6 Series Switches and Pilot ights Mounting Hole Size ø16 Model A6 AB6 AS6 AS6 (key) Disc tumbler key Shape Wave key Unit

More information

MW Series Control Units

MW Series Control Units IP waterproof and dust-proof enclosure Suitable for installation in harsh environment, such as construction machines Prevents entry of sand and dust. eliable operation under high operation load Solder/tab

More information

Emergency Stop Switches Selection Guide

Emergency Stop Switches Selection Guide Selection Guide New Concept Reverse Energy Structure Safe Break Action ø9mm Button E-BV3 (Solder, PC Board Terminal) Model Mark Page D-8 ø6m Mount Hole Non illuminated Detachable Block Pushlock Pull or

More information

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches Standard Interlock Safety Switches HS6B HS5E-K Key Locking Safety Key features: Head removal detection circuitry. High-security pin tumbler key types are used. Sixteen types of key numbers are available,

More information

XW Series Emergency Stop Switches

XW Series Emergency Stop Switches ø ø mm, 4-contact Emergency Stop Switch. Compact size only 37. mm deep behind the panel (screw terminal type 4 mm with terminal cover). eliable Safe break action. The depth behind the panel is only 37.

More information

[ Bezel size ] [ From panel front ] [ Shape ] [ Contact rating ] [ Action ] Unibody

[ Bezel size ] [ From panel front ] [ Shape ] [ Contact rating ] [ Action ] Unibody and Series Suitable for a wide variety of office and factory aplications. Features IE s original mechanism for snap-action switching. The E lamp contains a current-limiting resistor and a diode for protection

More information

LED Illumination Units

LED Illumination Units LED Illumination Units LF1D/LF2D IP67f LF1B IP54 LF1A IP4 LF1B-N IP65 LF1E IP54 LED Illumination Unit TM LED Illumination Unit Selection Lineup Shape Application Examples Illumination Color K: Color Temperature

More information

Style Contact Type No. Button Color Code ø40mm Mushroom 1NC YW1B-V4E01R YW1B-V4E21R. Gasket ø40 YW1L-V4E11Q0R 2NC YW1L-V4E02Q➂R 6 (12V AC/DC)

Style Contact Type No. Button Color Code ø40mm Mushroom 1NC YW1B-V4E01R YW1B-V4E21R. Gasket ø40 YW1L-V4E11Q0R 2NC YW1L-V4E02Q➂R 6 (12V AC/DC) Pushlock Pull/Turn eset Style Contact Type No. Button Color Code ø40mm Mushroom NC YWB-V4E0 2NC 3NC NO-NC NO-2NC 2NO-NC YWB-V4E02 YWB-V4E03 YWB-V4E YWB-V4E2 YWB-V4E2 ed only Dimensions Panel Thickness

More information

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch HS5E Series HS5E Series Miniature Solenoid Locking Switch HS5E Key features include: World s smallest 4 contact solenoid interlock switch. (35 40 46 mm.) Four contacts. Gold-plated contacts. Spring lock

More information

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm Emergency Stop Switch Mounting Aperture of 16 mm Modular construction, easy installation Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, Conforms to EN418

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Full Size Locking Switches Overview X Series E-Stops HSE features: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal screws

More information

PRODUCT SPECIFICATION. Stack Lights. Series.

PRODUCT SPECIFICATION. Stack Lights. Series. PRODUCT SPECIFICATION Stack Lights Series www.wernerelektrik.com Light Color Significance... Specifications... Functional Specification... Model Number Structure - Stack Lights... Model Number Selection...

More information

SA1W: Water Detection Sensors

SA1W: Water Detection Sensors Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA, 94080-6370 ain Office: (650) 588-9200 Outside Local Area: (800) 258-9200 www.steveneng.com The SA1W is the fastest, most reliable

More information

PS5R-S. Switching Power Supplies

PS5R-S. Switching Power Supplies TREICHL-ATM Electronic Auf der Bült 1-12 D 41189 Mönchengladbach Tel. 2166 8545 Fax 2166 8547 email: atm@treichl.de internet: www.atm-treichl.de PS5R-S Switching Power Supplies Class Create More Space

More information

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality Full Size Interlock Switch with Locking Solenoid HSC Key features include: Rugged Aluminum Die-cast Housing With the actuator mounted on a movable door, and the switch on a machine, the door can be mechanically

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Miniature Solenoid Locking Switches Overview X Series E-Stops HSE features: World s smallest 4 contact solenoid interlock switch. (3 x x 46 mm) Four contacts Gold-plated contacts

More information

Relays & Sockets. RQ Series PCB Relays

Relays & Sockets. RQ Series PCB Relays RQ RQ Series PCB Relays IDEC RQ relays are low-profile, PCB relays in a compact package. Size equals value. RQ relays are small, yet maintain high contact ratings and long operational life. For larger

More information

Emergency Stop Switches

Emergency Stop Switches Emergency Stop Switches Emergency Stop Switches (Selection Guide) Series Emergency Stop Switch Name ø6mm X6 Series Pushlock Pull / Turn Reset (Unibody) ø6mm XA Series Pushlock Pull / Turn Reset (Unibody)

More information

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded

More information

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight VDE 2c, 3c AMP POWER RELAY RELAYS 2. 1.72 FEATURES Interchangeable with existing models Long life and high reliability High contact capacity up to A 20 Available with plug-in/solder and quick-connect terminals

More information

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Series HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Key features include: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal

More information

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available with or without

More information

ø22mm HW Series Control Units Control Units

ø22mm HW Series Control Units Control Units mm HW Series Control Units Control Units HW Series Control Units (Selection Guide) Function Emergency Stop Switch (Unibody Type) Emergency Stop Switch (Separate Type) Pushlock Turn eset Category ø40mm

More information

LUMIFA LED Light Strips Long-lasting & so bright you gotta wear shades!

LUMIFA LED Light Strips Long-lasting & so bright you gotta wear shades! LUMIFA LED Light Strips Long-lasting & so bright you gotta wear shades! LF1A Series shown As IDEC continues to move towards a green future, we are excited to announce the LUMIFA series of LED light strips,

More information

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid HS1L Interlock Switches with Solenoid 3000N locking strength (largest in class)! * Suitable for large and heavy doors. Same actuator as HS1E (actuator retention force 3000N) Six contacts in a compact housing

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - A6 Series A6 Series Miniature Switches and Pilot Devices: 16mm Key features: 16mm (/8 ) mounting hole ED illumination ompact design saves space Momentary, Maintained, Selectors, and E-Stops Gold-clad

More information

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT NC NC RELAYS Flat type Flat type (PC board) (PC board) FEATURES 1. Compact, slim design Use of high-performance flat electromagnetic design achieves 10.9

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - 6 Series Key features: 5/8 (16mm) mounting holes ocking lever removable contact blocks Solder terminal or PB terminal options Available assembled or as sub-components Worldwide approvals Incandescent

More information

HS1E Series Full Size Solenoid Locking Switches

HS1E Series Full Size Solenoid Locking Switches HS1E Series Full Size Solenoid Locking Switches AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview HS1E features: Basic unit and solenoid unit in one

More information

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series Industrial Automation Catalog Section - U906 Relays Selection Guides General Purpose Relays RU Series RR Series For up-to-date information, or to request a full copy of this catalog, contact us at www.idec.com

More information

LED Annunciator Lights. KFE-HD Series

LED Annunciator Lights. KFE-HD Series LED Annunciator Lights KFE-HD Series KFE-24HD KFE-11HD KFE-13HD Features A variety of lighting areas, ranging from 8 34mm to 18 42mm are available. Five vivid lighting colors are available: milky white,

More information

22mm Push Buttons and Switches

22mm Push Buttons and Switches PUSH UTTONS/SWITCHES 22mm Push uttons and Switches Emergency Stops Selector Switches Lever Type Small Head 71.4 2 positions Large Head 3 positions unit: mm S2ER E3 R A D Size CONTACT LOCK * S2SR S 3 R

More information

30mm Hazardous Location Switches:

30mm Hazardous Location Switches: 30mm Hazardous Location Switches: EU2B Series PRODUCT DESCRIPTION Complying with UL and ATEX Directives for hazardous environments, new 30mm EU2B Hazardous Location Switches provide increased safety for

More information

30mm Hazardous Location Switches:

30mm Hazardous Location Switches: 30mm Hazardous Location Switches: EU2B Series PRODUCT DESCRIPTION Complying with UL and ATEX Directives for hazardous environments, new 30mm EU2B Hazardous Location Switches provide increased safety for

More information

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

HS6B Series Sub-Miniature Interlock Switch. Direct Opening HS6 Series HS6 Series Sub-Miniature Interlock Switch HS6 Key features include: Only 30mm x 15mm x 78mm Allows highest level of safety by having 3 contacts: dual load contacts + monitoring contact (ISO13849-1,

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations

More information

Lighted PushButton Switch

Lighted PushButton Switch Lighted PushButton Switch Cylindrical 8mm dia. Subminiature Series Featuring Short Mounting Depth Round, square and rectangular LED pushbutton units. types also available. Requires only 18mm mounting depth.

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices mm - Series Transfomer Contact Assemblies For use with Illuminated Pushbuttons. Style Contacts Part Number 12V AC with LED 24V AC with LED 48V AC with LED 12V AC with Incandescent 24V AC with Incandescent

More information

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers Standard Series Key features: Wide power range: 7.W-4W Universal input : 7.W-W: 8-264V /1-37V DC W: 8-2V /17-264V 24-37V DC (selectable) W, W, 24W: 8-264V /11-3V DC 4W: 3 phase: 32- V 3 phase: 3- V Overcurrent/overvoltage

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Exceptionally reliable general purpose relay Long life (minimum 100,000 electrical operations) assured by silver contacts Built-in operation indicator (mechanical, LED), diode surge

More information

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches HS5D Miniature Interlock Switches Head Removal Detection Function for Safer Performance Clearwater Tech - Phone: 8094.04 - Fax: 8.368.04 - Web: www.clrwtr.com - Email: info@clrwtr.com New Generation Miniature

More information

Door Interlock Switches

Door Interlock Switches HS5B Series HS5B Series Miniature Interlock Switch HS5B features: mm x mm x 9mm Compact Housing Available with Contact Confi gurations (NO + NC or NC) Flexible Installation: By turning the head of the

More information

Lighted Pushbutton Switch

Lighted Pushbutton Switch Lighted Pushbutton Switch General Purpose and Micro-Voltage/Current Load Switch Requires only 22 mm mounting depth All LEDs, lamps, legends and pushbutton units replaceable without tools Oil-resistant

More information

PS6R 480W Switching Power Supply

PS6R 480W Switching Power Supply ew Series PS6R 4W Switching Power Supply Reduced size and high efficiency cuts operating costs. Energy-saving 93% Efficiency Space-saving 85mm wide Efficiency (%) 96 94 92 88 86 84 82 Competitor A Competitor

More information

Miniature Switches & Pilot Devices

Miniature Switches & Pilot Devices ø16mm - 6 Series Miniature 6 Series Miniature Switches and Pilot Devices Key features of the 5/8 6 Series include: 5/8 (16mm) mounting holes ocking lever removable contact blocks Solder terminal or PB

More information

High Current, High Density, Power Connectors

High Current, High Density, Power Connectors High Current, High Density, Power Connectors MCN1 Series Features 1. High Current Applications Board-to-board connectors are UL certified for 27 A per contact. 2. Hirose's Unique Compliant Press-fit connection

More information

HS1C-P Interlock Plug Unit with Door Lock

HS1C-P Interlock Plug Unit with Door Lock HSC-P Unit with Lock Interlock plugs with door lock mechanism for high level safety management. Installing the actuator on the guard door and the interlock switch on the machine, the guard door can be

More information

Non-illuminated Push Buttons

Non-illuminated Push Buttons Non-illuminated Push Buttons 3 Accessories for push buttons Lockout attachment Contact block kits Lens kits Wobblestick kit Push Button Cap Interchangeable, snap-in design Protective caps 9 colors: red,

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Miniature DIN-track Mounting DC-DC Power Supplies 3- and 7.5-W models. Inputs: 10 to 27 VDC (DC input) Outputs: 5, 12, 15, 24, ±12, and ±15 V. 65 mm depth enables mounting onto panels

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Miniature Solenoid Locking Switches Overview X Series E-Stops HSE features: World s smallest 4 contact solenoid interlock switch. (3 x 40 x 146 mm) Four contacts Gold-plated contacts

More information

Solenoid Locking Safety Switches

Solenoid Locking Safety Switches HSC HSC Full Size Solenoid Locking Switches Key features: Rugged aluminum die-cast housing 00N locking retention force Flexible Installation: The actuator can be accessed from two directions Select from

More information

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada Key features: SPDT through PDT, 0 contacts Midget power type relays vailable in pin and blade terminal styles. Options include an indicator, check button for test operations and side flange. Series Power

More information

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key HSB Series Full Size Interlock Switch HSB features: Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available

More information

HS6B Series Subminiature Interlock Switch

HS6B Series Subminiature Interlock Switch HS6B Series Subminiature Interlock Switch HS6B features: Only 78 x 30 x 15mm Allows highest level of safety by having 3 contacts: dual load contacts + monitoring contact (ISO13849-1, EN954-1) Two actuator

More information

HS1E-K Interlock Switches with Solenoid (3-circuit)

HS1E-K Interlock Switches with Solenoid (3-circuit) HS1E-K Interlock Switches with Solenoid (-circuit) Dual main circuit + lock monitor circuit provide more safety to your system Basic unit and solenoid unit in one housing Lightweight plastic housing All

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1 S P E C I F I C A T I O N Edition 2 Page 1 ECS - INDUSTRIAL CONTROL SWITCH SELECTOR 1. FEATURES Up to 5 different operations. Detachable contact block for easy installation and removal. It can meet variety

More information

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz Miniature Magnetic Latching Key features of the RY2L series include: Standard ice cube, 14-pin solder lug termination Operates by pulse input and maintains condition even during power failure Coils rated

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - 6 Series 6 Series Miniature Switches and Pilot Devices Key features of the 5/8 6 Series include: 5/8 (16mm) mounting holes ocking lever removable contact blocks Solder terminal or PB terminal options

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Designed small, 2- and 3-pole types break 5 A loads and 4-pole type, 3 A load High reliability, long life Ultra-high sensitivity with quick response High vibration/shock resistance

More information

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs. Switching Expandable and space-saving switching power supplies. High efficiency reduces operation costs. 93% efficiency Plug-in output modules for additional output voltages Plug-in branch terminal module

More information

HS1C Interlock Switches with Solenoid

HS1C Interlock Switches with Solenoid HSC es with The guard door remains locked until the machine stops completely. With the actuator mounted on the guard door and the interlock switch on the machine, the door is mechanically locked when closed.

More information

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2 The SA1W is the fastest, most reliable liquid detection sensor on the market. Using a laser beam tuned to the resonant frequency of an H 2 O molecule, the SA1W is able to detect any liquid containing water

More information

KFD / KFT / KFR Series

KFD / KFT / KFR Series Incandescent Annunciator Lights KF / KFT / KFR Series KF-27F 27H 27V KF-37F 37H 37V KF-50F 50H Features Available in a variety of lighting panel sizes. 12 indicators (8 flat and 4 diagonal models) ranging

More information

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm Emergency Stop Switch For Panel Cutout of 16 mm H Modular construction, easy installation H Positive opening mechanism with a minimum contact separation of 3 mm in accordance with EN6947-5-1, for NC contacts