1 Installatin & Technical Manual SV2 / SV2-VH / SV3 / SV3-VH / SV4-VH

2 Table f Cntents SYSTEM OVERVIEW Safety Warnings... 1 Specificatin Sheet... 2 Cmpnent Overview... 3 Spa Pack Dimensins... 4 SV2.T Keypad Dimensins... 5 SV3.T / SV4.T Keypad Dimensins... 6 INSTALLATI PROCEDURES Flr munt spa pack installatin... 7 Wall munt spa pack installatin... 8 Keypad installatin (all mdels)... 9 Keypad cut-ut template Electrical Wiring (terminal blck cnnectins) Dip Switch settings Pump Cnfiguratins P Pwer Outlets (240V) Lw Vltage Outlets (12V) OEM PROGRMABLE OPTIS Prgram circuit breaker rating (current limit) OEM cnfiguratin menu Diagnstics menu Cntact Us i

3 ! WARNINGS Please read the fllwing befre installing r cnnecting this appliance RISK OF ELECTRICAL SHOCK All electrical cnnectins must be perfrmed by a licensed electrician and must cnfirm t all natinal, state and lcal electrical cdes in effect at the time f installatin. The appliance shuld be supplied thrugh a residual current device (RCD) having a rated residual perating current nt exceeding 30mA. The appliance must be cnnected t a suitable rated and weather prtected pwer supply. The supply line shuld be a dedicated pwer circuit and means fr discnnectin must be incrprated in the fixed wiring in accrdance with yur lcal wiring regulatins. Means fr discnnectin frm the supply mains shuld have a cntact separatin in all ples that prvide full discnnectin under ver vltage Categry III cnditins. T prevent electric shck hazard and/r water damage t this appliance, all unused receptacles must have a water prf seal in place. Parts incrprating electrical cmpnents must be lcated r fixed s that they cannt fall int the bath r spa. Parts cntaining live parts, except parts supplied with safety extra-lw vltage nt exceeding 12V must be inaccessible t a persn in the bath r spa. This appliance must nt be installed in prximity t highly flammable materials. Earthed appliances must be permanently cnnected t fixed wiring (Eurpean mdels nly). The appliance cntains n serviceable parts. D nt attempt service f this cntrl pack. Cntact yur dealer r authrized service agent fr assistance. Water temperature in excess f 38 C may cause hyperthermia (heat stress). It is the spa manufacturer's and/r installer's respnsibility t select suitable lads and cnfigure lad shed settings (if required) t ensure the system des nt exceed its rated maximum ttal lad. Turn the mains pwer befre servicing appliance r mdifying any cable cnnectin Suitable fr indr use nly r when installed under a weatherprf spa skirt. The appliance shuld be installed in an enclsure such that all electrical cnnectins cannt be accessible t the user withut the use f a tl. Lw vltage r imprper wiring may cause damage t this appliance. Read and fllw all wiring instructins when cnnecting t pwer supply. It is the installer's respnsibility t ensure the flr is capable f supprting the expected lad f the bath r spa and an adequate drainage system has t be prvided t deal with verflw water. A whirlpl spa shuld incrprate a water filtratin system where the required level f water purity can be achieved. An adequate drainage system has t be prvided if the equipment is t be installed in a pit. Any damaged cable must be replaced immediately. 1

4 SV Series Specificatins Electrical Specificatins Mdel N Max Maximum Multi Input Vltage Input Vltage Hz Heater Size Current Phase Current Single Phase* Three Phase* System Specificatins All Mdels (SV2/SV3/SV2-VH/SV3-VH/SV4-VH) SV2 15A V AC V AC 50/60 2kW SV3 45A V AC V AC 50/60 3kW SV2-VH 15A 16A per phase V AC V AC 50/60 3kW Variable SV3-VH 45A 25A per phase V AC V AC 50/60 6kW Variable SV4-VH 60A 25A per phase V AC V AC 50/60 6kW Variable * Range f acceptability (+/-6%) Output Ratings Outlet Max Current Output Vltage Hz Typical Accessry Maximum Cntrlled Temperature Thermal Cut-Out Maximum Ambient Temperature Minimum Flw Rate RCD trip rating Weight (withut cable) Dimensins (with cuplings) Enclsure 41 C 47 C +/-3 C 40 C 65 L/min 30mA 5kg 544x309x90mm IPx5 Circ 2A V AC 50/60 Small Circulatin Pump O3/UV 2A V AC 50/60 Ozne Generatr / UV Sanitiser Blwer 6.3A V AC 50/60 Air Blwer Pump 1 12A V AC 50/60 2 Spd Jet Pump / 1 Spd Jet Pump Pump 2 12A V AC 50/60 1 Speed Jet Pump Mains 1 ^ 12A V AC 50/60 Mains pwer utlet (always n) Operating Temperature Strage Temperature Humidity 0 C t 40 C -25 C t 85 C up t 85% RH (nn cndensing) Pump 3 * 12A V AC 50/60 2 Spd Jet Pump / 1 Spd Jet Pump Pump 4 # 12A V AC 50/60 1 Speed Jet Pump Mains 2 *^ 12A V AC 50/60 Mains pwer utlet (always n) ~ Light 1 1A 12V AC LED Light ~ Light 2 * 1A 12V AC LED Light * Outlets nt available n SV2 / SV2-VH mdels # Outlet nt available n SV2 / SV2-VH / SV3 / SV3-VH mdels ^ Dedicated mains pwer utlets (always ) ~ 1A maximum current draw. This is split between keypads, expand prts and light sckets. Each scket is rated t 1A maximum s the full 1A can be drawn frm a single scket if required. 2

5 SV Series Overview Mains Pwer Terminal Blck Heater Cnnectin Terminal Blck Fuse 1 (Phase 3 Lads) Fuse 2 (Phase 2 Lads) Fuse 3 (Phase 1 Lads) Lw Vltage Cnnectins (12V) keypads, lights, in-pl sensr digital/analg expand prts Mains Pwer Cable Entry Pints Heartbeat LED DIP Switch Bank Wall Munt Bracket Wall Munt Bracket P Pwer Outlets ( V AC) fr spa accessries: circ, 3/uv, air blwer jet pumps, auxiliaries Cupling (tail & nut) Cupling (tail & nut) Munting Ft Earth Bnding Terminal Heater Tube Heater Cver Plate (remve t access heater cnnectins) 3

6 TM Spa Pack Dimensins mm Frnt View mm 4 ADVANCED SPA CTROL variable heater Side View mm 6 mm mm Rear View mm mm mm Bttm View mm 6 mm mm mm mm mm 4

7 Keypad Dimensins mm SV2.T keypad 2.75" (70mm) LCD Screen 9 Keys Blue LED Backlighting mm 165mm x 94mm x 33.50mm 2.5m lead length SV-2T mm 6.00 mm mm mm mm R 37mm mm 5

8 Keypad Dimensins mm SV3.T / SV4.T keypad 3.5" (90mm) LCD screen 12 keys mm RGB clur mixing LED backlighting 185mm x 100mm x 33.50mm SV-3T 2.5m lead length mm 6.00 mm mm mm mm R 37mm mm 6

9 TM Spa Pack Installatin Flr munting prcedure WATER FLOW WATER FLOW 4 ADVANCED SPA CTROL variable heater Due t its flexible design the spa pack can be installed n either the suctin side r the discharge side f the filtratin pump. Select a suitable lcatin n the spa base and firmly secure spa pack t base using fur (4) x screws f apprpriate length backed with flat washers. Each screw shuld be psitined in the mulded cut uts f the munting feet (refer abve & aside). The spa pack shuld be fixed using ALL fur screw lcatins t prvide adequate supprt (tw screws n each side f the spa pack). IMPORTANT NOTE The spa pack is NOT intended t be used utdr. The spa pack must be installed in indr envirnments nly and shuld be installed in an enclsure s that all electrical cnnectins cannt be accessible withut the use f a tl (ie. under spa cabinet). NOTES Only use pan, rund r truss head screws with flat washers DO NOT use cuntersunk screws. They may damage r crack the mulded munting brackets The spa pack must be installed with the heater tube hrizntal and shuld be psitined as lw as pssible in the pipe wrk f the spa. The spa pack must be plumbed s that water flws frm left t right fr crrect water detectin and accurate temperature sensing. When cnstructing a spa care shuld be taken t minimise vibratin frm the pumps transferring t the spa pack thrugh the base, frame r pipe wrk. Extended perids f vibratin may lead t early cmpnent failure. The spa pack shuld be lcated at least 10cm (4") abve ptential fld level. If spa flr is n grund level the spa pack shuld be raised 10cm (4") abve spa flr level. Install spa pack in a suitable psitin t prevent water dripping nt the unit. In particular avid installing spa pack directly underneath keypad munting lcatin. 7

10 TM Spa Pack Installatin Wall munting prcedure Due t its flexible design the spa pack can be installed n either the suctin side r the discharge side f the filtratin pump. Select a suitable lcatin under the spa and use tw (2) x (2x4) treated timber beams r ther suitable timber r metal materials t cnstruct an adequate supprt structure t munt the spa pack t. The munting supprt frame shuld be capable f supprting the weight f the spa pack and shuld withstand the frce f the pipe wrk mving each time the filtratin pump starts r stps. 4 ADVANCED SPA CTROL variable heater Firmly secure spa pack t supprt frame using ALL fur (4) x screw hle lcatins prvided n the mulded munting brackets (refer aside) Only use pan, rund r truss head screws / blts backed with flat washers DO NOT use cuntersunk screws r blts. They may damage r crack the mulded munting brackets NOTES The spa pack must be installed with the heater tube hrizntal and shuld be psitined as lw as pssible in the pipe wrk f the spa. The spa pack must be plumbed s that water flws frm left t right fr crrect water detectin and accurate temperature sensing. IMPORTANT NOTE WATER FLOW The spa pack is NOT intended t be used utdr. The spa pack must be installed in indr envirnments nly and shuld be installed in an enclsure s that all electrical cnnectins cannt be accessible withut the use f a tl (ie. under spa cabinet). When cnstructing a spa measures shuld be taken t minimise vibratin frm the pumps transferring t the spa pack thrugh the base, frame r pipe wrk. Extended perids f vibratin may lead t early cmpnent failure. The spa pack shuld be lcated at least 10cm (4") abve ptential fld level. If spa flr is n grund level the spa pack shuld be raised 10cm (4") abve spa flr level. Install spa pack in a suitable psitin t prevent water dripping nt the unit. In particular avid installing spa pack directly underneath keypad munting lcatin. 8

11 Keypad Installatin All Mdels (SV2.T / SV3.T / SV4.T) Centre t Centre mm SV2.T Select a suitable keypad lcatin that is abve maximum water level and that is easily accessible t the spa user. Befre drilling the cut ut fr the keypad, hld the keypad in place and check there is sufficient cable length t reach the spa pack withut the cable being stretched r pulled against sharp edges. Drill tw 76mm diameter hles spaced 71mm apart frm centre t centre (as illustrated aside). Cut ut the residual material between the tw hles (as illustrated). Clean munting surface t be free f dirt and dust particles, il and grease. T ensure the keypad adhesive bnds t the spa well the shell must have a clean, smth and dry surface. Peel paper backing frm adhesive gasket ensuring all f the adhesive is expsed. 76 mm 76 mm Feed cable thrugh pening, align keypad and press firmly nt munting surface. Ensure keypad is adhered well t surface by pressing evenly arund the utside edge f the whle keypad. IMPORTANT NOTES SV3.T / SV4.T The keypad munting lcatin shuld have adequate drainage t prevent accumulatin f water n r arund the keypad area. If keypad is t be munted under a spa cver allw sufficient clearance t prevent cver resting directly n keypad. Parts incrprating electrical cmpnents (ie. keypads) must be fixed s that they cannt fall int the bath r spa KEYPAD CABLE CNECTI 76 mm Unscrew and remve lw vltage cnnectins cver frm spa pack enclsure Cnnect keypad RJ45 plug int either TPAD1 r TPAD2 scket 147 mm Drip Lp Rute the keypad cable thrugh the cable guide prvided Ensure the keypad cable has a drip lp befre it enters the enclsure 9

12 SVT Keypad Cut Out Template SV2.T / SV3.T / SV4.T (Scale 1:1) NOTE: T print in 1:1 scale, set Page Scaling t NE in the print dialg bx Centre t Centre mm 1 Drill bth hles 2 with 76mm Hle Saw After drilling bth hles remve this material frm bth sides 76 mm 76 mm 10

13 Electrical Wiring (Terminal Blck Cnnectins) AUS / NZ / Eurpean Mdels ( V AC) Tls Required: Wire Strippers, Phillips head screwdriver, flat head screwdriver Remve five (5) x Phillips screws frm mains lid t access terminal blck. Cut away apprpriate length f uter insulatin frm mains pwer cable and strip away 25mm (1") f wire insulatin frm the end f each wire. Rute mains cable thrugh ne f the tw snap ut hles prvided and secure the cable with a gland t prvide adequate cable strain relief (Tighten gland with use f a tl t ensure supply line anchrage pint cannt be remved by hand).. Push the wires int the crrect terminals as labelled. Refer wiring guide belw r n the sticker inside the terminal blck area. Tighten all screws n the terminal blck with a flat head screwdriver and check t ensure each wire has been firmly secured. Then screw mains lid back n. WARNING This appliance must be supplied thrugh a residual current device (RCD) having a rated residual perating current nt exceeding 30mA. Crrect wiring f the main electricity bard, RCD and spa pack is critical. When installing appliance refer t yur lcal wiring regulatins. When installing mains pwer cable prviding service lps (additinal wire length fr future serviceability) t incming wiring is recmmended. P3 P2 CS P1 G N P3 P2 CS P1 G N P3 P2 CS P1 G N V (3 wire) single phase V (4 wire) dual phase V (5 wire) three phase Terminal Wiring Terminal Wiring Terminal Wiring P3 P2 CS P1 G N Link t CS Link t CS Link t P3 and P2 Phase Earth Neutral P3 Phase 2 P2 Link t CS CS Link t P2 P1 Phase 1 G Earth N Neutral P3 Phase 3 P2 Phase 2 CS Nt used P1 Phase 1 G Earth N Neutral *Dip Switch 5 *Dip Switch 6 *Dip Switch 5 *Dip Switch 6 *Dip Switch 5 *Dip Switch 6 * Refer Dip switch infrmatin n page 11 11

14 DIP Switch Settings System Cnfiguratin Basic spa cnfiguratin is achieved by setting dip switches. The dip switches determine pump cnfiguratin and select the number f input phases wired t the spa pack. The installer must crrectly cnfigure the dip switches t match the pump and pwer cnfiguratin cnnected t the spa pack. The dip switch bank (illustrated aside) has six individual switches. Switches set t the tp f the switch bank are in the psitin. Switches set t the bttm f the switch bank (clsest t the numbers) are in the psitin. Refer t tables belw fr dip switch settings: SW Setting Ntes SV2 / SV4 Mdels 1 Circ Fitted Nt Fitted Fitted 2 Pump 1 Type Single Speed Tw Speed If set t pump2 assumed fitted 3 Pump 3 Type Single Speed Tw Speed Nt used n SV2/SV2-VH mdels 4 Pump 4 Fitted Nt Fitted Fitted Nt used n SV2/SV2-VH mdels 5 Phase Selectin Single Phase 2/3 Phase If set t dip switch 6 is enabled 6 Multi Phase Tw Phase Three Phase SW Setting Ntes SV3 Mdels Heartbeat LED 1 Circ Fitted Nt Fitted Fitted 2 Pump 1 Type Single Speed Tw Speed If set t pump2 assumed fitted 3 Pump 3 Fitted Nt Fitted Fitted 4 Nt Used Phase Selectin Single Phase 2/3 Phase If set t dip switch 6 is enabled 6 Multi Phase Tw Phase Three Phase Heartbeat LED Dip Switch Bank All SV mdel spa packs feature a heartbeat LED. The heartbeat LED flashes t indicate the current health/status f the spa pack. When the spa pack is functining crrectly with n errrs t reprt the heartbeat LED emits a single flash in a cnstant pulse much like a heartbeat (,,, ). If the spa pack encunters a fault the heartbeat LED will begin flashing in sequence with the errr cde number being experienced (ie. ER2 =,;,; ). The heartbeat LED is lcated beside the bttm left hand crner f the dip switch bank and will emit its red flash thrugh the tinted lw vltage cnnectin cver, making it clearly visible frm the frnt f the spa pack. 12

15 Pump Cnfiguratins System Cnfiguratin Reference Table ntes n/a = nt available If pump1 = 2 spd, the pump 2 utlet scket cannt be used If pump3 = 2 spd, the pump 4 utlet scket cannt be used 13

16 P Pwer Outlets V AC Output Multiple pwer utput sckets are prvided t run spa accessries. Each utput scket is clearly labelled including the maximum current fr that utlet. In additin the maximum current per phase is labelled. When cnnecting accessries the installer must cnsider the current draw f each appliance t be cnnected and ensure the system des nt exceed the maximum lad limits. The utput sckets are wired with three sckets per phase (refer table belw). The nly exceptin is phase 1 which als pwers the heater element (a scket is nt prvided, the heater is wired internally). Each phase circuit is prtected by a fuse. P Pwer Outlets The sum ttal current draw f all appliances cnnected t a phase shuld nt exceed the maximum current limit f that respective phase. Refer t ratings infrmatin labels n spa pack fr current limits. In single phase applicatins the utlet sckets are still gverned by the fuse/current limit f each phase. The pwer utlet arrangement is as fllws: PHASE 1 PHASE 2 PHASE 3 Securing Lugs Lcking Tabs circulatin pump pump 1 pump 3 sanitiser (zne/uv) pump 2 pump 4 blwer mains* mains* heater# Plug Overmuld * Dedicated V pwer utlets (always n) # Heater is cnnected internally t phase 1. Cnsider when calculating ttal current draw f phase 1 P Sckets & Plugs SV series spa packs utilise P mate-n-lk pwer cnnectrs. The P cnnectrs feature a key pattern fr fail safe ne way cnnectin. When cnnecting accessry devices be sure t push crdset firmly int scket and ensure bth side lcking taps have been secured and latched in place (refer illustratins aside). P Outlets Cver Firmly secured and latched in place P Outlets Cver 12 Fr installatins where there is insufficient depth under the spa skirt fr the cable radius f an ver mulded plug the installer can pt t fit the amp utlet cver and use nn ver mulded plugs t achieve a tighter cable radius. If accessries are cnnected with nn ver mulded P plugs the P utlet cver MUST be installed and fixed with screws. t The P utlet cver features snap ut sectins t be cut away at pint f install t suit quantity f crds in use. 14

17 Lw Vltage Cnnectins 12V AC The lw vltage cnnectins are lcated n the tp right hand crner f the spa pack. RJ45/RJ11 sckets are used fr cnnectin and are lcated inside the spa pack enclsure. The lw vltage cnnectins cver must be fitted and secured with screws fr water prfing seal t wrk. Lw Vltage Cnnectins Cable guide hles used t rute cables and frm water prf seal The SV cntrllers feature the fllwing lw vltage cnnectins: Scket Accessry TPAD1 Keypad #1 TPAD2* Keypad #2 IPTS In pl temperature sensr EXPAND1 Digital expansin prt EXPAND2 Analgue expansin prt LIGHT1 LED Light Output LIGHT2* LED Light Output * Sckets nt available n SV2/SV2-VH mdels Drip Lp IMPORTANT NOTES 1A maximum 12V current draw. This is split between keypads, expand prts and lights. Each scket is rated t 1A maximum s the full 1A can be drawn frm a single scket if required. Ensure each lw vltage cable is ruted thrugh the cable guide hle n the side f the spa pack and allw fr drip lps befre entry t the enclsure. Prt current sensing in pl temperature sensr The SV series spa packs mnitr the RMS current drawn frm the lw vltage prts at all times. 12V current drawn by keypads, in pl temp sensrs, expand prts and lights are measured. If the current is abve 1.1A the cntrller will shut dwn and latch fault cde (Er6-12V verlad). Digital expand prt A PC cmmunicatins and general purpse digital interface prt. Mst suited t interfacing t ther digital equipment such as steres, remte cntrls etc Analg expand prt clur LED spa light An analg expansin prt that cntains tw analg inputs and a digital I2C bus. The I2C bus is shared with tuch pad 1 prt and allws cnnectin f NXP I2C family f devices. 15

18 Prgram Circuit Breaker Rating Fr variable element peratin Press & hld + Current sensing Each VH (variable heater) mdel f SV cntrller cntains mains current measurement hardware that allws the cntrller t mnitr the RMS current draw. The current sensing hardware is nly installed n Phase 1. Phases 2 and 3 can als be mnitred if they are wired t terminal CS f the mains terminal blck (refer wiring infrmatin n page 10). 31 A SA SU MO TU WE TH FR Press Press C.LMT SA SU MO TU WE TH FR t enter adjustment 32 A SA SU MO TU WE TH FR t cnfirm & save 33 A SA SU MO TU WE TH FR Current measurement is used fr variable element peratin. The purpse is t autmatically adjust heater size t match the residual current available when accessry devices (ie pumps and/r blwer) are perating. The aim is t maximise heating input whilst spa is in use, but still remain within the current limit f the cntrller. The OEM menu item C.LMT (current limit) shuld be set t match the rating f the circuit breaker that feeds the spa pl. T take full advantage f the variable element and maximise heater size when spa in manual use the circuit breaker rating must be prgrammed crrectly. The SV cntrller will shut dwn and latch fault cde (Er10 - ver current) if the SV cntrller detects a mains current abve 110% f C.LMT. The actual current draw f the spa pack can be viewed at anytime via the diagnstics menu r by using the SpaNET Link PC applicatin. The default current limit (C.LMT) values fr each mdel are as fllws: Mdel Default C.LMT IMPORTANT NOTES The installer must prgram the C.LMT (current limit) setting t match the rating f the circuit breaker that feeds the spa pl fr crrect cntrller peratin and safe pwer management. The C.LMT (current limit) setting is stred in nn vlatile memry (EEPROM) s it is remembered when pwer is turned ff. The C.LMT setting nly needs t be prgrammed nce. C.LMT value is nt adjusted by EEPROM reset. If the C.LMT (current limit) setting is nt matched t the circuit breaker rating crrectly the spa wner may experience either tripping circuit breakers r Er10 Over Current latching errrs. SV2-VH 15 amp SV3-VH 32 amp SV4-VH 40 amp Hw t prgram the current limit (C.LMT) : Press and hld and buttns tgether until C.LMT is displayed Press buttn t enter current limit (C.LMT) adjustment Press r t adjust current limit t match circuit breaker rating Press buttn t cnfirm and save setting 16

19 SA SU MO TU WE TH FR OEM Cnfiguratin Menu Access via keypad The SV cntrllers feature a hidden OEM cnfiguratin menu which allws cmplete custmisatin f the spa pack. Menu item ptins are detailed in the list belw. T enter menu press and hld and buttns until [C.LMT] is displayed Press r t navigate thrugh menu item list EXIT SA SU MO TU WE TH FR Press & hld + C.LMT SA SU MO TU WE TH FR L.SHD Menu Item Setting Ntes Press t enter menu item adjustment Press r t adjust setting Press t cnfirm setting and exit menu 31 A SA SU MO TU WE TH FR Press Press IMPORTANT NOTES t enter adjustment 32 A SA SU MO TU WE TH FR t cnfirm & save The OEM menu item settings are stred in nn vlatile memry (EEPROM) and are remembered when pwer is turned ff. N need t reprgram settings when pwer is restred. During an EEPROM reset all menu items will be restred t the factry default settings except C.LMT/1.LLM/2.LLM/3.LLM/V.MAX. A ten (10) secnd idle menu time ut perid exists. If a buttn press is nt detected fr 10 secnds the menu will time ut and the screen will return t the default display mde. 33 A SA SU MO TU WE TH FR C.LMT Current Limit (circuit breaker rating) 10 t 60A L.SHD Lad Shed Cunt 1 t 7 SANI Sanitiser ( 3/uv) n with spa use n / ff C.JET Circ pump n with jet pump peratin n / ff F.CYC Filtratin cycle blck time adjustment 1,2,3,4,6,8,12,24 hrs V.ELE Variable element n / ff V.MAX Maximum variable element pwer 30 t 100% (5% increments) 1.LLM Phase 1 lad limit 1 t 5 2.LLM Phase 2 lad limit 1 t 5 (item disappears if set t 1 phase) 3.LLM Phase 3 lad limit 1 t 5 (item disappears if set t 1 r 2 phase) UNIT Temperature frmat C r F A.HYS Adaptive hysteresis limit 0 t 20 C, 0.2 C increments (0=disabled) S 24 Sanitiser ( 3/uv) n 24 hrs n / ff C 24 Circ pump n 24 hrs n / ff CAL Calibratin Adjust Menu C.ZER Mains current zer push OK buttn t zer reading C.ADJ Mains current reading adjust with up/dwn buttns V.ADJ Mains vltage reading adjust with up/dwn buttns EXIT SERT Exit calibratin submenu Service timers menu 1.SER Service timer 1 [service filter] 0 t 52 wks (0 wks = disabled) 2.SER Service timer 2 [service 1] 0 t 52 wks (0 wks = disabled) 3.SER Service timer 3 [service 2] 0 t 52 wks (0 wks = disabled) EXIT Exit service timers submenu EPRM Reset EEPROM values t factry default All values reset except C.LMT/1.LLM/2.LLM/3.LLM EXIT Exit OEM cnfiguratin menu 17

20 OEM Cnfiguratin Menu Menu item details L.SHD Lad Shed Cunt V.ELE Variable Element Operatin This setting determines the lad shed behaviur f the heating element. Lad shedding is gverned by the lad shed cunt (1 t 7). Lad shed cunt = number f lads required t be turned fr the heater t lad shed and turn. The filtratin pump is nt cunted as a lad, the blwer and all ther pumps are. Example: Lad Shed Cunt = 2 When any tw lads in additin t the filtratin pump are turned the heater lad sheds and turns. The L.SHD setting ranges frm 1 t 7. 1 = maximum lad shed (default) 7 = lad shed disabled Variable element peratin allws the SV cntrller t autmatically adjust the heater pwer level t match the residual current available when accessry devices (ie pumps and/r blwer) are perating. The benefit f this feature is the element can autmatically reduce its size and remain n instead f lad shedding and turning ff when spa is in manual use and jet pumps have been activated. The setting chices are: variable element enabled (default) variable element disabled Nte: If disabled the heating behaviur is the same as a standard element. Lad shed settings may need t be cnfigured t ensure the spa pack des nt exceed its maximum current limit. SANI Sanitiser ( 3/uv) Operatin V.MAX Maximum Variable Element Size Determines hw the sanitiser pwer utlet perates during manual spa use. The setting chices are: sanitiser with pl use sanitiser with pl use (default) If variable element peratin is enabled the installer als has the ability t limit the pwer level supplied t the heating element (30 t 100%) via the V.MAX menu item. This enables the installer t reduce the heater size where available pwer is limited, withut the need t replace the heater element r spa pack. It als allws fr the heater t be returned t maximum size if mre pwer became available. C.JET Circ n with Jet Pump The V.MAX setting ranges frm 30% t 100% Default setting = 100% Determines behaviur f circ pump when jet pump is turned n fr manual spa use. The setting chices are: F.CYC circ pump frced with jet pump use circ pump cntrlled autmatically (default) Filtratin Cycle Blcks Filtratin cycles can be prgrammed t run as ften as every hur r as little as nce every 24 hurs. Use this setting t adjust the frequency f the filtratin cycle perids. The F.CYC setting chices are fr filtratin t ccur every 1,2,3,4,6,8,12 r 24 hurs. 18 x.llm Lad Limit Settings (Phases 1/2/3) This setting allws the installer t select the maximum number f lads (1-5) allwed t run at the ne time. Different lad limits can be set fr each phase. 1.LLM = Phase 1 Lad Limit 2.LLM = Phase 2 Lad Limit 3.LLM = Phase 3 Lad Limit Example: 1.LLM = 2 This will allw 2 x accessries (pump(s) and/r blwer) t run at the ne time, but as sn as yu try and turn the 3rd accessry n the buttn will nt wrk until yu turn ne f the ther accessries ff first. Only 2 x lads will ever be allwed t run at the ne time.

21 OEM Cnfiguratin Menu Menu item details UNIT Temperature Frmat Used t select desired temperature frmat A.HYS Adaptive Hysteresis The SV cntrllers feature adaptive hysteresis fr heat cntrl t reduce demand heating cycling. Adaptive hysteresis cntrl tunes the temperature sensing t that particular spa pl and envirnment. It is particularly advantageus when in heater temperature sensing is emplyed. The A.HYS menu item allws the installer t set the maximum range that hysteresis can be adjusted. The A.HYS setting ranges frm 0 t 20 C A value f 0 disables adaptive hysteresis Default = 20 C S 24 Sanitiser (24 hurs) The setting allws the sanitiser pwer utlet t be pwered 24 hurs per day The setting chices are: C 24 sanitiser pwer utlet always sanitiser pwer utlet autmatically cntrlled (default) Circ Pump (24 hurs) The setting enables the circ pump utlet t be pwered 24 hurs per day The setting chices are: CAL C r F circ pump pwer utlet always circ pump pwer utlet autmatically cntrlled (default) Calibratin Adjustment Submenu Every SV cntrller is calibrated fr mains vltage and current measurement during prductin. Hwever, shuld the SV cntrller readings nt agree with a multi meter reading they can be adjusted. The CAL sub menu ffers the fllwing ptins: C.ZER Mains current zer push OK buttn t zer reading C.ADJ Mains current reading adjust with up/dwn buttns V.ADJ Mains vltage reading adjust with up/dwn buttns EXIT Exit calibratin submenu Field adjustment f the vltage reading shuld fllw the fllwing prcedure: 1) Measure the mains vltage using a gd quality multi meter. 2) Adjust the vltage reading using V.ADJ t match the multi meter. Field calibratin f the current reading shuld fllw the fllwing prcedure: 1) Stp any current draw by discnnecting any fixed 230V lads and switching ff heating, pumps, blwer etc 2) Zer the current reading using C.ZER. 3) Apply maximum pump lads and measure the current draw using a gd quality multi meter. 4) Adjust current reading using C.ADJ t match multi meter reading. The SV measures the mains current that flws frm Phase 1 terminal t phase 1 lads (heater, blwer, zne, circ). Any ther lads cnnected via the CS terminal are als measured. x.ser Service Timers These settings are used t enable and adjust service timers. A value f 0 results in the timer being disabled. Maximum timer value is 52 weeks. Independent cunters are stred in R and therefre reset t 0 at pwer up. Cunters fr each service timer are incremented everyday at 8am. When the cunter is greater r equal t the service timer value x 7, the tuch pad will beep and scrll a message twice every 60 secnds. 1.SER message = "SERVICE FILTERS" 2.SER message = "SERVICE 2" 3.SER message = "SERVICE 3" The particular cunter is reset by pressing the OK buttn whilst the service message is scrlling. 19

22 Diagnstics Menu Access via keypad The SV cntrllers feature a hidden diagnstics menu which allws the installer / spa user t view nbard diagnstics and histrical details abut the spa cntrller. Menu item ptins are detailed in the list belw. I T enter menu press and hld and and buttns Press r t navigate thrugh menu item list Press t view diagnstic infrmatin n the selected item Press & hld + + I Menu Item Setting Ntes WARN Warnings scrll IPTS presence, W8, mde, Vmax/Vmin EXIT SA SU MO TU WE TH FR WARN SA SU MO TU WE TH FR S.DAT SA SU MO TU WE TH FR S.DAT State date scrll Date displayed in DD - MM - YY S.VER Sftware versin scrll TYPE Cntrller type scrll PUMP Pump selectin scrll LIMS Limits scrll Refer table belw fr further Limits details Press t view diagnstic infrmatin IPTS H.TMP Current IPTS reading Current heater temperature reading C.TMP Current case temperature PS Current mains current draw VOLT Current mains vltage V.ELE Current variable element pwer level 0 t 100% EXIT Exit menu IMPORTANT NOTE A ten (10) secnd idle menu time ut perid exists. If a buttn press is nt detected fr 10 secnds the menu will time ut and the screen will return t the default temperature display mde. The limits scrll prvides a scrlling list f all current, phase and lad limit settings as prgrammed in the OEM menu r set by dip switches. This feature is a quick way t verify cntrller settings. The list f items that will be displayed are: C.LMT Current limit setting (10 t 60A) L.SHD Lad shed cunt (1 t 7) PHSE Phase cnfiguratin (1,2 r 3 phase) 1.LLM Phase 1 lad limit (1 t 5) 2.LLM Phase 2 lad limit (1 t 5) 3.LLM Phase 3 lad limit (1 t 5) P.HYS H.HYS Current pl temperature sensr adaptive hysteresis value (0-200; where 1 = 0.1'C) Current heater temperature sensr adaptive hysteresis value (0-200; where 1 = 0.1'C) 20

23 Cntact Us Spa Net Pty Ltd Unit Railway Rad Nrth Mulgrave NSW 2756 Australia Phne: Fax: service@spanet.cm.au accunts@spanet.cm.au sales@spanet.cm.au Technical Supprt & Service Accunts Department Sales Department 21

HIGH POWER RGB LED SERIES. The HB Series Advantage! Architectural Illumination Systems!

HIGH POWER RGB LED SERIES. The HB Series Advantage! Architectural Illumination Systems! The HB Series Advantage SGS listed cnfirming t UL Standard 2108 & 8750 Certified t CSA Standard C22.2 N.9 LED Life f 50K+ hurs, under nrmal perating cnditins Lw wattage, lw heat, lw vltage (12DVC & 24VDC

More information

Installation Guide Contigo 6100

Installation Guide Contigo 6100 Installatin Guide Cmmercial Vehicle Prductivity and Security The is a high-perfrmance beacn designed fr cmmercial prductivity and security. It is ideally suited t installatins in delivery and service fleets

More information

EnergyBar 6. Setup Guide

EnergyBar 6. Setup Guide EnergyBar 6 Setup Guide WELCOME Cngratulatins n yur purchase f the Apex EnergyBar 6! The EnergyBar 6 allws the Apex system t cntrl up t six 230 vlt items such as lights, pumps, fans, heaters, chillers

More information

Model: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS

Model: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS 120 Mdel: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE INTRODUCTION This Wired Wall Timer system was

More information

EDBRO RIGID INCLINOMETER

EDBRO RIGID INCLINOMETER EDBRO RIGID INCLINOMETER RINC01 Installatin & Operating Instructins E5542 rev 1 (June 2010) Edbr PLC Nelsn Street, Bltn BL3 2JJ UK Tel: +44 (0) 120 4528888 Fax: +44 (0) 120 4531957 E-mail: pstmaster@edbr.cm

More information

Trouble Shooting Guide for AFVK-SP Series Valve Kit (AF-4000 Series Gas Valves)

Trouble Shooting Guide for AFVK-SP Series Valve Kit (AF-4000 Series Gas Valves) Truble Shting Guide fr AFVK-SP Series Valve Kit (AF-4000 Series Gas Valves) AFVK-SP, AFVK-SP-H/L, AFVK-SP-MH/L AFVK-SP Series Valve Kit Truble Shting Guide (AF-4000 Series) TABLE OF CONTENTS General Infrmatin

More information

Installation Guide Contigo 6150 & 6151

Installation Guide Contigo 6150 & 6151 Installatin Guide Cntig 6150 & 6151 Cmmercial Vehicle Prductivity and Security The Cntig 6150 & 6151* (cllectively knwn as the Cntig 615X) are highperfrmance beacns designed fr cmmercial prductivity and

More information

WELCOME. WEB LOCATION Los Angeles, CA

WELCOME. WEB   LOCATION Los Angeles, CA WELCOME Thank yu fr chsing AC Infinity. We are cmmitted t prduct quality and friendly custmer service. If yu have any questins r suggestins, please dn t hesitate t cntact us. Visit www.acinfinity.cm and

More information

PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D),

PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D), SERVICE REPLACES: Please discard ATV 07-02 dated 4/5/07 MODEL: PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D), KFX700 (KSV700-A/B/C),

More information

CS369-R51I Thank you very much for purchasing our air conditioner.

CS369-R51I Thank you very much for purchasing our air conditioner. OWNER'S MANUAL CONDITIONER REMOTE CONTROLLER ILLUSTRATION The design and specificatins are subject t change withut prir ntice fr prduct imprvement. Cnsult with the sales agency r manufacturer fr details.

More information

ABTQ-103 rev 01 Last review:

ABTQ-103 rev 01 Last review: INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH PCS Cntrl Statin Purpse f Instructins Wrking in hazardus areas, the safety f persnnel and plant depends n cmplying with all relevant safety

More information

DriveCam Unit Installation Instructions

DriveCam Unit Installation Instructions DriveCam Unit Installatin Instructins Installatin f the DriveCam Unit is nt cmplicated, thugh care must be taken t avid specific prblems. Sme vehicles require additinal cnsideratin t determine the ptimum

More information

NEXT UPS Systems MANTIS II Tower 750/1000/1500 Installation and user manual English

NEXT UPS Systems MANTIS II Tower 750/1000/1500 Installation and user manual English NEXT UPS Systems MANTIS II Twer 750/1000/1500 Installatin and user manual English CONTENT IMPORTANT SAFETY INSTRUCTIONS... 1 1. Intrductin... 4 2. Descriptin f Features... 4 3. Package Cntents... 4 4.

More information

Anemómetros digitales portátiles AN-100 extech manual ingles USER MANUAL. Model AN100. CFM/CMM Thermo Anemometer AN100

Anemómetros digitales portátiles AN-100 extech manual ingles   USER MANUAL. Model AN100. CFM/CMM Thermo Anemometer AN100 USER MANUAL CFM/CMM Therm Anemmeter Mdel AN100 CFM/CMM Therm-Anemmeter AN100 Intrductin Cngratulatins n yur purchase f the Extech AN100 CFM/CMM Therm Anemmeter. This instrument measures Air Velcity, Air

More information

Advanced 3 Million Wireless USB Limousine Underbody Kit

Advanced 3 Million Wireless USB Limousine Underbody Kit Advanced 3 Millin Wireless USB Limusine Underbdy Kit Warning: Please check yur state and lcal laws befre installing this LED underbdy kit. Every state has different plicies and prcedures in place regarding

More information

Car Refrigerator PFN-C-WEA-25/35/45/55

Car Refrigerator PFN-C-WEA-25/35/45/55 Car Refrigeratr PFN-C-WEA-25/35/45/55 Accessries available separately:- Prtective Transit Bag AC0V -240Vt DC 2 V Pwer Adaptr Please read this manual carefully befre using yur unit. Sectin Page Key Prduct

More information

FIRST: Top battery (closest to the arm) SECOND: Middle battery. LAST: Top battery (furthest from arm)

FIRST: Top battery (closest to the arm) SECOND: Middle battery. LAST: Top battery (furthest from arm) Hw t Install the Batteries Hw t Hld the Lamp: The InteliEnergy Lamp selectin switches utilize the same technlgy as cell phnes: Capacitive Tuch. This assures the ultimate in lngevity because there are n

More information

EDBRO TRAILER INCLINOMETER

EDBRO TRAILER INCLINOMETER EDBRO TRAILER INCLINOMETER TINC01 (12V AND 24V VERSIONS) Installatin & Operating Instructins E5541 rev 5 (Sept 2015) Edbr PLC Nelsn Street, Bltn BL3 2JJ UK Tel: +44 (0) 120 4528888 Fax: +44 (0) 120 4531957

More information

VEHICLE ACTIVATED SPEED LIMIT SIGNS

VEHICLE ACTIVATED SPEED LIMIT SIGNS VEHICLE ACTIVATED SPEED LIMIT SIGNS TRS-VASL VEHICLE ACTIVATED SPEED LIMIT SIGNS Vehicle Activated Speed Limit (VASL) signs measure the speed f appraching vehicles. If the speed f the vehicle is higher

More information

WELCOME. WEB LOCATION Los Angeles, CA

WELCOME. WEB   LOCATION Los Angeles, CA WELCOME Thank yu fr chsing AC Infinity. We are cmmitted t prduct quality and friendly custmer service. If yu have any questins r suggestins, please dn t hesitate t cntact us. Visit www.acinfinity.cm and

More information

Introduction Specifications Structure & Performance Assembly Folding Operation Care & Maintenance...

Introduction Specifications Structure & Performance Assembly Folding Operation Care & Maintenance... n Intrductin... 3 Specificatins... 4 Structure & Perfrmance... 5 Assembly... 6 Flding... 7 Operatin... 8-12 Care & Maintenance... 13-15 2 P a g e Read and fllw all instructins, warnings, and ntes in this

More information

INSTALLATION INSTRUCTIONS FOR PART #47002 WATER / METHANOL INJECTION SYSTEM UNIVERSAL TURBO DIESEL

INSTALLATION INSTRUCTIONS FOR PART #47002 WATER / METHANOL INJECTION SYSTEM UNIVERSAL TURBO DIESEL Kit Cntents INSTALLATION INSTRUCTIONS FOR PART #47002 WATER / METHANOL INJECTION SYSTEM UNIVERSAL TURBO DIESEL Parts UHO Pump (Ultra High Output) 3 Qt Reservir 10 ft High Pressure Tubing 3 ft Black Wire

More information

INVERTER/CHARGERS EVOLUTION SERIES. Off-Grid Power Solutions. How an Inverter/ Charger. Works... ORDER NOW

INVERTER/CHARGERS EVOLUTION SERIES. Off-Grid Power Solutions. How an Inverter/ Charger. Works... ORDER NOW D yu yu need reliable AC pwer in a vehicle, remte lcatin r fr emergency back-up? Samlex s inverter/charger is THE chice fr a cmplete ff-grid pwer slutin. Off-Grid Pwer Slutins LUTION SERIES S Sine 1 Pure

More information

Technical Manual. eluma. Aluminum Frame LED Panels. patents pending. Technical Specifications Subject to Change

Technical Manual. eluma. Aluminum Frame LED Panels. patents pending. Technical Specifications Subject to Change Technical Manual eluma Aluminum Frame LED Panels patents pending TM Technical Specificatins Subject t Change TABLE OF CONTENTS General Specificatins.. Page 3 Prfile Specificatins EL001.. Page 4 Prfile

More information

TECHNICAL SPECIFICATION. SPC-4T Stirling Process Cryogenerator

TECHNICAL SPECIFICATION. SPC-4T Stirling Process Cryogenerator TECHNICAL SPECIFICATION SPC-4T Stirling Prcess Crygeneratr Reference 80 8044_00 Issue Date April 20, 2016 Stirling Crygenics is a registered trade name f DH Industries BV Fr mre infrmatin n the Stirling

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Observer Zning Bard ZONE0101ZP6 These instructins must be read and understd cmpletely befre attempting installatin Safety Labeling and Signal Wrds DANGER, WARNING, CAUTION, and

More information

E+ Battery Care Guide

E+ Battery Care Guide Electric Mtin Systems, LLC 45150 Business Curt, Suite 300 Dulles, VA 20166 USA E+ Battery Care Guide Welcme! Yur E+ Hub Battery Pack is a pwerful, sphisticated, and imprtant part f yur E+ Electric Bicycle.

More information

Installation instructions: 13 Pin Electrical system for towing hitch

Installation instructions: 13 Pin Electrical system for towing hitch General data Part number Westfalia Vehicle Manufacturer Vehicle 321 538 300 153 ZGB 1T0 055 204 Vlkswagen Turan MY 2003> 321 538 391 105-005 - 33/07 Imprtant ntes Read the installatin manual prir t starting

More information

100 KW / 125 KVA POWERED by

100 KW / 125 KVA POWERED by 100 KW / 125 KVA POWERED by MODEL Tritn Pwer is a wrld leader in the design, manufacture f statinary, mbile and rental generatr sets and Pwer Mdules frm 10 t 2000 kw. Thrugh ur cmmitment t quality we manufacture

More information

ADVISORY: General Motors Upfitter Integration Bulletin #108d P a g e 1 May 18, 2016

ADVISORY: General Motors Upfitter Integration  Bulletin #108d P a g e 1 May 18, 2016 Subject: Aftermarket ALDL r DLC Interface Devices Causing Multiple Issues Mdels All Passenger Cars and Trucks Affected: Mdel Years: 2006 and beynd Date: February 4, 2013 Revisin Date: May 18, 2016 ADVISORY:

More information

REMOTE GREASING KIT FOR MORGANS SERIES 2

REMOTE GREASING KIT FOR MORGANS SERIES 2 Fitting Instructins REMOTE GREASING KIT FOR MORGANS SERIES 2 Thank yu fr purchasing a Remte Greasing Kit fr yur Mrgan. These fitting instructins shuld enable yu t fit the kit t yur Mrgan. Depending n which

More information

GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS SECURITY SYSTEM KIT CONTENTS SHOCK SENSOR F-D15 WINDOW DECAL (QTY 2) F-D16

GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS SECURITY SYSTEM KIT CONTENTS SHOCK SENSOR F-D15 WINDOW DECAL (QTY 2) F-D16 GENUINE ACCESSRIES INSTALLATIN INSTRUCTINS PART NUMBER: 0000-8F-N03 NTE: NT CMPATIBLE WITH REMTE START SYSTEM, PART# 0000-8F-N02 SECURITY SYSTEM KIT CNTENTS APPLICABLE MDELS: 2007>MAZDA CX-9 WITHUT ADVANCED

More information

XJ 4-Link Rear Long Arm Instructions

XJ 4-Link Rear Long Arm Instructions Parts Checklist: Instructins Irn Rck Off Rad Decal - (2) Rck-Link Decal 13287 - (2) irnrckffrad.cm Decal - (1) Crssmember - 991162 - (1) Shck crssmember - 91173 - (1) Shck crssmember spacer - 91178 - (2)

More information

PSS INSTALLATION INSTRUCTIONS

PSS INSTALLATION INSTRUCTIONS PSS INSTALLATION INSTRUCTIONS Imprtant - Read Befre Starting! Befre starting yur installatin carefully read the fllwing warnings and instructins. Failure t prperly fllw the warnings and instructins culd

More information

LED Driver Feedback Signs

LED Driver Feedback Signs LED Driver Feedback Signs Installatin Instructins (029-04151-0000) Nvember 2012 Slar Kit 35AH / 55W 70AH / 55W 70AH / 85W M75-SOLAR-000S M75-SLR70-000S M75-SOLAR-000C E. 5676 Seltice Way Pst Falls, Idah

More information

Pre-Planning Delivery Guide

Pre-Planning Delivery Guide Pre-Planning Delivery Guide Need Assistance? Call 1-888-768-6772 Pre-Delivery Spa Delivery Preparatin Yur spa delivery will arrive CURBSIDE at the specified delivery address yu prvided at the time f yur

More information

Parts Checklist: XJ Front 3-Link Long Arm Upgrade Installation Instructions *BOX 1* *BOX 2* Jeep Cherokee XJ

Parts Checklist: XJ Front 3-Link Long Arm Upgrade Installation Instructions *BOX 1* *BOX 2* Jeep Cherokee XJ XJ Frnt 3-Link Lng Arm Upgrade Installatin Instructins 84-01 Jeep Cherkee XJ Parts Checklist: *BOX 1* Instructins Invice Lg decal 10001 (1) Rck-Link decal 13287 (2) Irnrckffrad.cm decal (1) Subframe center

More information

Tools Required. Installation. Step 1. Headlight lense removal (Driver's side shown, Passenger side similar)

Tools Required. Installation. Step 1. Headlight lense removal (Driver's side shown, Passenger side similar) Tls Required Phillips Screw Driver (crner lamps) Flat Head Screw Driver (ptinal fr headlight cver) Pliers (handy t have) Electrical Tape Sturdy Cpper Wire (t use as a wire fish) 10mm Scket r Wrench (grund

More information

INSTALLATION INSTRUCTIONS FOR PART #20010 RT1/RT2/DOM WATER / METHANOL INJECTION SYSTEMS

INSTALLATION INSTRUCTIONS FOR PART #20010 RT1/RT2/DOM WATER / METHANOL INJECTION SYSTEMS Kit Cntents INSTALLATION INSTRUCTIONS FOR PART #20010 RT1/RT2/DOM WATER / METHANOL INJECTION SYSTEMS Parts UHO Pump (Special High Output) 3 Qt Reservir 10 Ft High Pressure Tubing 3 Ft Wire Lm 18 1/8 Silicne

More information

Traffic Logix SafePace 475 Radar Speed Signs Product Specifications Version 1.2

Traffic Logix SafePace 475 Radar Speed Signs Product Specifications Version 1.2 Traffic Lgix SafePace 475 Radar Speed Signs Prduct Specificatins Versin 1.2 1 Table f Cntents Dimensins... 3 Sign Weight... 3 Accessries... 3 Technical Specificatins... 4 Pwer... 4 Radar... 4 Display...

More information

Parts Checklist: ZJ Front 3-Link Long Arm Upgrade Installation Instructions *BOX 1* *BOX 2* Jeep Grand Cherokee ZJ

Parts Checklist: ZJ Front 3-Link Long Arm Upgrade Installation Instructions *BOX 1* *BOX 2* Jeep Grand Cherokee ZJ ZJ Frnt 3-Link Lng Arm Upgrade Installatin Instructins 93-98 Jeep Grand Cherkee ZJ Parts Checklist: *BOX 1* Instructins Invice Lg decal 10001 (Qty: 1) Rck-Link decal 13287 (2) Irnrckffrad.cm decal (1)

More information

Parts Checklist: WJ Front 3-Link Long Arm Upgrade Installation Instructions *BOX 1* (1) *BOX 2* (1) Jeep Grand Cherokee WJ

Parts Checklist: WJ Front 3-Link Long Arm Upgrade Installation Instructions *BOX 1* (1) *BOX 2* (1) Jeep Grand Cherokee WJ Parts Checklist: *BOX 1* 13319 (1) Instructins Lg decal 10001 (Qty: 1) Rck-Link Decal 13287 (2) Irnrckffrad.cm decal (1) Subframe center 92270 (1) Subframe left uter 92256 (1) Subframe right uter 92275

More information

INSTALLATION INSTRUCTIONS FOR PART #20001 FORCED INDUCTION BOOST COOLER WATER / METHANOL INJECTION SYSTEMS

INSTALLATION INSTRUCTIONS FOR PART #20001 FORCED INDUCTION BOOST COOLER WATER / METHANOL INJECTION SYSTEMS INSTALLATION INSTRUCTIONS FOR PART #20001 FORCED INDUCTION BOOST COOLER WATER / METHANOL INJECTION SYSTEMS Parts UHO (Ultra High Output) Pump 3 Qt Reservir 10 ft High Pressure Tubing 3ft Wire Lm 18 1/8

More information

MEDMASTER TROFFER Luminaires for MRI/Imaging Suites LED MRIT SERIES

MEDMASTER TROFFER Luminaires for MRI/Imaging Suites LED MRIT SERIES MEDMASTER TROFFER Luminaires fr MRI/Imaging Suites PRODUCT FEATURES: Recessed munt Grid; 2' 2', 2' 4' Nn-ferrus cnstructin safe fr sensitive MRI equipment High-utput, high-cri LED lamp ptins NSF2 rating

More information

EP12M248 7 Stage Automatic Smart Battery Charger, Desulphuration& Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

EP12M248 7 Stage Automatic Smart Battery Charger, Desulphuration& Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL EP12M248 7 Stage Autmatic Smart Battery Charger, Desulphuratin& Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1

More information

Audi 8L A3 and B5 A4 ColorMFA Install Guide ColorMFA from AutoPilot. Instructions from Clusters by Litke and pinout from Drive2

Audi 8L A3 and B5 A4 ColorMFA Install Guide ColorMFA from AutoPilot. Instructions from Clusters by Litke and pinout from Drive2 Audi 8L A3 and B5 A4 ClrMFA Install Guide ClrMFA frm AutPilt. Instructins frm Clusters by Litke and pinut frm Drive2 This is an verview guide n hw t install the v3.2/v3.4 ClrMFA units int Audi 8L and B5

More information

FUELS SAFETY BRANCH INFORMATION BULLETIN July 1994

FUELS SAFETY BRANCH INFORMATION BULLETIN July 1994 FUELS SAFETY BRANCH INFORMATION BULLETIN July 1994 Guidelines fr Maintenance and Inspectin Prgrams fr Natural Gas and Prpane Appliances and their Fuel Features In Schls The Ontari Gas Utilizatin Cde states

More information

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-211Y PIPE TORCH/BURNER MACHINE. by BLUEROCK Tools

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-211Y PIPE TORCH/BURNER MACHINE. by BLUEROCK Tools Vlume 1.1 OPERATIONAL MANUAL MODEL: CG-211Y PIPE TORCH/BURNER MACHINE by BLUEROCK Tls UNPACKING THE ITEM Cautin: This machine is packed tgether with items that may be sharp, ily and verly heavy bjects.

More information

PRE-PLANNING & DELIVERY GUIDE

PRE-PLANNING & DELIVERY GUIDE TM PRE-PLANNING & DELIVERY GUIDE Need Assistance? Call 1-888-329-4847 PRE-DELIVERY Spa Delivery Preparatin Yur spa delivery will arrive CURBSIDE at the specified delivery address yu prvided at the time

More information

72 Mustang Mach 1 tachometer cluster and gauge conversion

72 Mustang Mach 1 tachometer cluster and gauge conversion 72 Mustang Mach 1 tachmeter cluster and gauge cnversin Dated: 02-17-2009 (drafted by a Chevy persn wrking n his first Frd -nt gd-) The fllwing infrmatin pertains t hw I went abut cnverting the standard

More information

D-Sub adaptor Cable clamps for metric cable entries Cable clamps for PG cable entries Further Accessories

D-Sub adaptor Cable clamps for metric cable entries Cable clamps for PG cable entries Further Accessories Cntents Accessries Page D-Sub adaptr............................................... 40.02 Han Split Hd.............................................. 40.04 Cable clamps fr metric cable entries..............................

More information

Traffic Logix SafePace 450 (Full & Compact) Radar Speed Signs Product Specifications Version 1.6

Traffic Logix SafePace 450 (Full & Compact) Radar Speed Signs Product Specifications Version 1.6 Traffic Lgix SafePace 450 (Full & Cmpact) Radar Speed Signs Prduct Specificatins Versin 1.6 2014-2016 Traffic Lgix Crpratin www.tapcnet.cm 5100 West Brwn Deer Rad Brwn Deer, WI 53223 1 Table f Cntents

More information

JD F Conversion. Combine Manual a

JD F Conversion. Combine Manual a JD 9000-600F Cnversin Cmbine Manual 09040114a Abut Headsight Headsight Cntact Inf Headsight, Inc Bremen, IN 46506 Phne:574-546-5022 Fax: 574-546-5760 Email: inf@headsight.cm Web: www.headsight.cm Technical

More information

Methanol Recovery Systems

Methanol Recovery Systems Methanl Recvery Systems Methanl Recvery fr bidiesel is an imprtant part f the entire bidiesel prcess and invlves the highest cst f peratin fr a bidiesel plant. Only abut half f the methanl used is actually

More information

IQUPS.com Have you checked the IQ of your Power Systems?

IQUPS.com Have you checked the IQ of your Power Systems? IQUPS.cm Have yu checked the IQ f yur Pwer Systems? TMSPDC Transprtable Mdular (Trailer-Mdular Pwer Strage - Offices) Characteristics: Transprtable; Mdular; Simple; Rugged; Military Grade. Systems Designed

More information

Rejuvenation Instructions

Rejuvenation Instructions Rejuvenatin Instructins #521 200A Elbws UPR This NRI cvers the fllwing: Hw t prepare 200amp pre-mlded elbws fr injectin. Hw t install and re-infrce an injectin elbw. Hw t size an injectin elbw t match

More information

INSTALLATION INSTRUCTIONS FOR PART #50015 DIESEL MPG-MAX WATER / METHANOL INJECTION SYSTEM 6.0L/6.4L/6.7L POWERSTROKE DIESEL

INSTALLATION INSTRUCTIONS FOR PART #50015 DIESEL MPG-MAX WATER / METHANOL INJECTION SYSTEM 6.0L/6.4L/6.7L POWERSTROKE DIESEL Kit Cntents INSTALLATION INSTRUCTIONS FOR PART #50015 DIESEL MPG-MAX WATER / METHANOL INJECTION SYSTEM 6.0L/6.4L/6.7L POWERSTROKE DIESEL Parts 7 Galln Reservir UHO Pump (Ultra High Output) 25 ft High Pressure

More information

Safe Handling of High Voltage Electrical components in Electrical End of Life Vehicles

Safe Handling of High Voltage Electrical components in Electrical End of Life Vehicles Safe Handling f High Vltage Electrical cmpnents in Electrical End f Life Vehicles The fllwing infrmatin is extracted frm the dcument Safe Handling f High Vltage Electrical cmpnents in Electrical End f

More information

Self Consumption in residential systems

Self Consumption in residential systems Self Cnsumptin in residential systems Brad Bassett Sr. Applicatin Engineer Jan 27, 2017 San Dieg, CA What is Self Cnsumptin? A direct grid tie system is where slar energy prduced, pwers the huse lads as

More information

Traffic Logix SafePace 400 Radar Speed Sign Product Specifications Version 1.2

Traffic Logix SafePace 400 Radar Speed Sign Product Specifications Version 1.2 Traffic Lgix SafePace 400 Radar Speed Sign Prduct Specificatins Versin 1.2 Traffic Lgix Crp. I 3 Harriet Lane I Spring Valley, New Yrk 10977 T (866) 915-6449 F (866)995-6449 I www.trafficlgix.cm I inf@trafficlgix.cm

More information

DTC P0401 Exhaust Gas Recirculation Flow Insufficient Detected

DTC P0401 Exhaust Gas Recirculation Flow Insufficient Detected DTC P0401 Exhaust Gas Recirculatin Flw Insufficient Detected DESCRIPTION Based n the driving cnditins, the ECM regulates the vlume f exhaust gas that is recirculated t the engine's cmbustin chambers and

More information

Tips & Technology For Bosch business partners

Tips & Technology For Bosch business partners Tips & Technlgy Fr Bsch business partners Current tpics fr successful wrkshps N. 35/2011 Gasline injectin Invented fr life Lambda sensr Knw-hw frm the market leader Bsch, innvative cmpany and wrld's largest

More information

LN products. Contents. LN Cabinets for LAN applications. LN Enclosures. LN Open Racks

LN products. Contents. LN Cabinets for LAN applications. LN Enclosures. LN Open Racks LN prducts LN Cabinets fr LAN applicatins The LN cabinets is lightweight and a gd chice fr slutins where the required lad-bearing capacity is nt great and the applicatins are installed indrs. The cabinets

More information

A very common arrangement for oil lubricated stern tube bearings. A simplex seal arrangement is fitted to both inner and outer ends.

A very common arrangement for oil lubricated stern tube bearings. A simplex seal arrangement is fitted to both inner and outer ends. Simplex shaft seal A very cmmn arrangement fr il lubricated stern tube bearings. A simplex seal arrangement is fitted t bth inner and uter ends. The replaceable chrme liner prevents damage t the prp shaft

More information

USER`s Manual. Swivelling semi-automatic press. Swivelling manual press TECHNICAL DATA. - works without compressor

USER`s Manual. Swivelling semi-automatic press. Swivelling manual press TECHNICAL DATA. - works without compressor USER`s Manual Swivelling semi-autmatic press Swivelling manual press TECHNICAL DATA - wrks withut cmpressr - pens autmatically ( nly Swing S ) - swivels autmatically aside ( nly Swing S ) Dimensins in

More information

Open Street Cam User Manual

Open Street Cam User Manual Open Street Cam User Manual Table f cntent 1.Installing the app and setting it up fr the first time 1.1 Installing the app 1.2 Setting up the app fr the first time 2. Installing the smartphne in the car

More information

Traffic Logix SafePace 475 Radar Speed Signs Product Specifications Version 1.0

Traffic Logix SafePace 475 Radar Speed Signs Product Specifications Version 1.0 Traffic Lgix SafePace 475 Radar Speed Signs Prduct Specificatins Versin 1.0 1 Table f Cntents Dimensins... 3 Sign Weight... 3 Accessries... 3 Technical Specificatins... 4 Pwer... 4 Radar... 4 Display...

More information

Compact Safedrive with built-in Safety Brake. innovative drive systems for industrial doors. Variable Speed Safedrive with built-in Safety Brake

Compact Safedrive with built-in Safety Brake. innovative drive systems for industrial doors. Variable Speed Safedrive with built-in Safety Brake GfA-ELEKTROMATEN Chain Drive Operatr fr Rller Shutter Cmpact Safedrive with built-in Safety Brake Safedrive with built-in Safety Brake Chain Drive with separate Safety Brake Fire Shutter Operatr innvative

More information

Gearbox Installation Manual

Gearbox Installation Manual Gearbx Installatin Manual Rtrk Gears HOB/MPR & HOS/MPR ranges (Electrnic cpy available n www.rtrk.cm)! This manual cntains imprtant safety infrmatin. Please ensure it is thrughly read and understd befre

More information

/2017. Flexline rapid clamping systems with drive chain clamping element, T-slot and adjustment track

/2017. Flexline rapid clamping systems with drive chain clamping element, T-slot and adjustment track Traveling unit chain (adjustment track) in 3 lengths s in varius designs Mtr Advantages 8 different clamping elements 4 different T-slts 3 different adjustment tracks drive mtr and die mnitr attachable

More information

BIG-VUE Series Meter

BIG-VUE Series Meter USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet BIG-VUE Series Meter File N. E471457 LAC DU FLAMBEAU,WI LAC DU FLAMBEAU,WI 1/2 The mving irn & mving cil panel meters sizes 2 " 1/2, 3 " are

More information

VYLEATER DAILY HOUSEKEEPING & PREVENTATIVE MAINTENANCE PROCEDURES. Follow these procedures to keep your Vyleater running smoothly.

VYLEATER DAILY HOUSEKEEPING & PREVENTATIVE MAINTENANCE PROCEDURES. Follow these procedures to keep your Vyleater running smoothly. VYLEATER DAILY HOUSEKEEPING & PREVENTATIVE MAINTENANCE PROCEDURES! WARNING! Failure t fllw these prcedures may cause an verlad cnditin that culd result in the Vyleater becming severely damaged. Fllw these

More information

Instruction Manual. PHscan30 Pocket ph Tester

Instruction Manual. PHscan30 Pocket ph Tester Hazardus Substance Statement Bante is cmmitted t the reductin and eventual eliminatin f all hazardus substances in bth the manufacturing prcess and finished prducts we supply. We have an active manufacturing

More information

Motorized Pulley 165E, Ø 165 mm

Motorized Pulley 165E, Ø 165 mm Mtrized Pulley 165E, Ø 165 mm Mtrized Pulley 165E, with machined helical gear b, perfrms an efficiency, in a cmpact diameter f 165 mm nly. With a min RL f 400 mm and and pwers ranging frm 0.11kW t 1.5kW

More information

Uninterruptible Current Supply USV V / 1.2 Ah

Uninterruptible Current Supply USV V / 1.2 Ah Uninterruptible Current Supply USV 011 +24 V / 1.2 Ah The USV 011 Uninterruptible current supply is used t buffer the +24 V supply f an Industry PC (C-IPC, SIPC). The +24 V supply is nrmally cnnected t

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Observer Zning Panel ZONE0101ZP6 These instructins must be read and understd cmpletely befre attempting installatin Safety Labeling and Signal Wrds DANGER, WARNING, CAUTION, and

More information

BioWave Hydro DI-9200 User Manual

BioWave Hydro DI-9200 User Manual BiWave Hydr DI-9200 User Manual Assembling Hydr DI 9200: Assembling yur BiWave Hydr DI 9200, is a very shrt and simple prcess. All yu have t d is take the Hydr DI 9200 ut f the bx, make sure its standing

More information

Tormach CNC Mill PCNC1100

Tormach CNC Mill PCNC1100 Trmach CNC Mill PCNC1100 Machine Purpse: CNC machine used fr precisin cutting, drilling & frming Safety: Must wear safety glasses while perating machine. Keep. Beware f bjects that dangle and culd get

More information

OWNER S MANUAL. DCR-205-XX-DC Powered Drum Rotators

OWNER S MANUAL. DCR-205-XX-DC Powered Drum Rotators VESTIL MANUFACTURING CORP. 2999 N. Wayne St., Angla, IN 46703 Ph: 260-665-7586 Fax: 260-665-1339 E-mail: sales@vestil.cm Website: www.vestil.cm 0317 DCR-205-DC, MANUAL DCR-205-XX-DC Pwered Drum Rtatrs

More information

Appointment Plus User Instructions

Appointment Plus User Instructions Appintment Plus User Instructins This dcument prvides the user with instructins fr the Appintment Plus System. Appintment Plus System Features This is a tl fr managing the fllwing: Technician Wrk Frce

More information

Refer to the description for DTC P0C Refer to DESCRIPTION.

Refer to the description for DTC P0C Refer to DESCRIPTION. Print 203 Tyta Prius 8L Eng Plug-In P34A REQUESTED INFORMATION Dtc P34A-828: Inverter Clant Pump Speed Signal Descriptin Refer t the descriptin fr DTC P0C73-776 Refer t DESCRIPTION The inverter water pump

More information

Mini H1 Twin Kit - Installation Instructions

Mini H1 Twin Kit - Installation Instructions Intrductin: Thanks fr purchasing the Mini H twin kit! Yu are very clse t imprve yur lightning nw :) Please read this manual carefully. Feel free t cntact us r visit ur Facebk cmmunity; Eurpean Headlight

More information

3000-series Remote Start System with Keyless Entry. Owner's Guide

3000-series Remote Start System with Keyless Entry. Owner's Guide 3000-series Remte Start System with Keyless Entry Owner's Guide Cngratulatins Cngratulatins n the purchase f yur state-f-the-art remte start system with keyless entry. Reading this Owner s Guide prir

More information

Medication Cart. Featuring AutoLock Security System. Product Manual

Medication Cart. Featuring AutoLock Security System. Product Manual AC Medicatin Cart Featuring AutLck Security System Prduct Manual Cpyright and Distributin Ntice December 2009 Cpyright 2009 Capsa Slutins, Inc. ALL RIGHTS RESERVED. Published 2014. Printed in the United

More information

{EMS Shock} Student Name: Period:

{EMS Shock} Student Name: Period: {EMS Shck} Student Name: Perid: 5 th Grade Engineering Pulleys Unit Rubric Lab #0016 Pulley Frame Pulley Frame: Student cnstructed the Pulley Frame t lab specificatins. Pulley Frame was nt apprved 0 pints

More information

03-06 TJ Long Arm Upgrade Instructions

03-06 TJ Long Arm Upgrade Instructions Parts List: Instructins Irn Rck Off Rad lg decal (2) Irnrckffrad.cm decal (1) Belly skid plate 85046 (1) Left lng arm frame munt 85121 (1) Right lng arm frame munt 85122 (1) Left LCA munt gusset plate

More information

Car & Key Memory functions for series E38, E39 (from 09/98), E46, E52, E53, R50 and R53 from start of series production

Car & Key Memory functions for series E38, E39 (from 09/98), E46, E52, E53, R50 and R53 from start of series production Car & Key Memry functins fr series E38, E39 (frm 09/98), E46, E52, E53, R50 and R53 frm start f series prductin Structure 1 Car Memry 1.1 Anti-theft alarm system 1.2 Central lcking system 1.3 Pwer windws

More information

Machine Safeguarding

Machine Safeguarding Machine Safeguarding General This dcument will prvide yu a high-level verview n sme best practices pertaining t machine guarding and sample types f guards fund in manufacturing settings. The Main Causes

More information

CS ENERGY PROCEDURE FOR LADDERS CS-OHS-52. Key Changes Prepared By Checked By Approved By Date

CS ENERGY PROCEDURE FOR LADDERS CS-OHS-52. Key Changes Prepared By Checked By Approved By Date CS ENERGY PROCEDURE FOR LADDERS CS-OHS-52 Respnsible Officer: Respnsible Executive: Grup Manager Health and Safety Executive General Manager Crprate DOCUMENT HISTORY Key Changes Prepared By Checked By

More information

Installation Instructions AQ-5100, AQ-5200 & AQ-5300 Under Counter Water Filter Single Stage (5100), Two Stage (5200) and Three Stage (5300) systems

Installation Instructions AQ-5100, AQ-5200 & AQ-5300 Under Counter Water Filter Single Stage (5100), Two Stage (5200) and Three Stage (5300) systems Live Healthy s ' p V iv Installatin Instructins AQ-5100, AQ-5200 & AQ-5300 Under Cunter Water Filter Single Stage (5100), Tw Stage (5200) and Three Stage (5300) systems Welcme t the Aquasana experience.

More information

Safety Rules. Danger Failure to obey the instructions and safety rules in this manual will result in death or serious injury. Do Not Operate Unless:

Safety Rules. Danger Failure to obey the instructions and safety rules in this manual will result in death or serious injury. Do Not Operate Unless: Third Editin First Printing Operatr's Manual Safety Rules Danger Failure t bey the instructins and safety rules in this manual will result in death r serius injury. D Nt Operate Unless: Yu learn and practice

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS PN: ISDUALSWG Rev: D OWNER S MANUAL INSTALLATION, OPERATION, & PARTS DUAL SUBMERGED SUCTION OUTLET SET [Cmmnly called main drains] Basic safety precautins shuld always be fllwed, including the fllwing:

More information

READ ALL INSTRUCTIONS THOROUGHLY FROM START TO FINISH BEFORE BEGINNING INSTALLATION!

READ ALL INSTRUCTIONS THOROUGHLY FROM START TO FINISH BEFORE BEGINNING INSTALLATION! www.fabtechmtrsprts.cm 4331 EUCALYPTUS AVE ~~ CHINO, CA 91710 PHONE 909-597-7800 ** FAX 909-597-7185 1994-2001 DODGE RAM 1500 & 2500 4 WHEEL DRIVE FTS3400-50 FRONT DUAL SHOCK SYSTEM PARTS LIST: 1 EA. FT3400-50-100P

More information

Installation Instructions

Installation Instructions Part Number: CPECOMZR007A00 SMALL PACKAGED PRODUCT (3 TON UNITS) VERTICAL ECONOMIZER ACCESSORY EXCLUDING 3 TON 14 SEER HP AND DUAL FUEL MODELS Installatin Instructins Read these instructins cmpletely befre

More information

BPC955 V0 Bliss Powercom Genset Controller. Kirloskar Electric Co. Ltd. User Manual

BPC955 V0 Bliss Powercom Genset Controller. Kirloskar Electric Co. Ltd. User Manual BPC955 V0 Bliss Pwercm Genset Cntrller Kirlskar Electric C. Ltd User Manual This dcument applies t Prduct 9001-0049 Build Versin 3600-0129 Firmware Versin 5000-xxxx The infrmatin cntained in this dcument

More information

SICO 1800 Single & Dual-Height Stage System A single or dual-height mobile folding stage with carpet or hard tuff-deck surface.

SICO 1800 Single & Dual-Height Stage System A single or dual-height mobile folding stage with carpet or hard tuff-deck surface. SICO 1800 Single & Dual-Height Stage System A single r dual-height mbile flding stage with carpet r hard tuff-deck surface. Features, Advantages & Benefits Deck Cnstructin Cnstructed with durable 5/8 thick

More information

GLOBAL LIFT CORP. Owner s Manual. Superior Series Proformance Series S-350 / P-375

GLOBAL LIFT CORP. Owner s Manual. Superior Series Proformance Series S-350 / P-375 GLOBAL LIFT CORP Owner s Manual Superir Series Prfrmance Series S-350 / P-375 684 N Prt Crescent Rd Suite C Bad Axe, MI 48413 Tll Free: 866-712-0606 Fax: 989-269-5902 www.glballiftcrp.cm Page 1 SUPERIOR

More information

Operator s Manual with Maintenance Information. Second Edition Fourth Printing Part No

Operator s Manual with Maintenance Information. Second Edition Fourth Printing Part No Operatr s Manual with Maintenance Infrmatin Secnd Editin Furth Printing Part N. 48643 Operatr s Manual Secnd Editin Furth Printing Imprtant Read, understand and bey these safety rules and perating instructins

More information

Headsight HHC HH 14 series. Combine Manual

Headsight HHC HH 14 series. Combine Manual Headsight HHC HH 14 series Cmbine Manual 09010204 Abut Headsight Headsight Cntact Inf Headsight, Inc Bremen, IN 46506 Phne:574-546-5022 Fax: 574-546-5760 Email: inf@headsight.cm Web: www.headsight.cm Technical

More information

E.COM GmbH LEDLUM LTX TRI-PROOF. Tri-Proof LTX Serie. Optional mit Microwave Motion Sensor. Direkt Montage. Schwenkbare Montage. Seilabhänger Montage

E.COM GmbH LEDLUM LTX TRI-PROOF. Tri-Proof LTX Serie. Optional mit Microwave Motion Sensor. Direkt Montage. Schwenkbare Montage. Seilabhänger Montage E.COM GmbH Tri-Prf LTX Serie Optinal mit Micrwave Mtin Sensr LEDLUM LTX TI-POOF Direkt Mntage Schwenkbare Mntage Seilabhänger Mntage 5 D 5.8GHz Matters needing attentin Befre installing the lighting fixtures,

More information