Section 13. TemBreak 1 MCCBs and Mining MCCBs

Size: px
Start display at page:

Download "Section 13. TemBreak 1 MCCBs and Mining MCCBs"

Transcription

1 TemBreak 1 MCCBs and Mining MCCBs Section Amp rating TemBreak 1, selection, stocking and location guide 15A 1600 XS15NS XH15NJ XSNJ, XHNJ XHPJ, XH0PJ XS0NJ 0 7 XH0SE 0 8 XS630NJ and XS800NJ XH630PJ and XH800PJ XS/XH630SE and XS/XH800SE TL630NE, TL800NE and TL1NE XS1SE and XS1600SE XS ND, DC MCCBs to 15 TL100EM XV0, XV630, XV800 and XV1 Mining MCCBs Accessories for the above MCCB 18 to 30 TemBreak 1 MCCB ordering sheet 31 Ratings charts 3 to 4 Selectivity and Cascade charts 43 to 45 Characteristic Curves 46 to 51 Electronic MCCB curve and setting data 5 to 57 Dimensions 58 to 69 Page 1

2 TemBreak 1 Selection, stocking and location guide Amps ka OCR Type Hydraulic/magnetic Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic Electronic Electronic Electronic Thermal magnetic Thermal magnetic Thermal magnetic Electronic Electronic Electronic Thermal magnetic Thermal magnetic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Thermal magnetic Thermal magnetic Electronic Electronic Electronic Electronic Magnetic Thermal magnetic Electronic Electronic Electronic Electronic Base current adj. Fixed Fixed Fixed % % % % Fixed % % % % % % % 100 % 100 % 100 % % % % 100 % 100 % 100 % % % 100 % 100 % 100 % 100 % 100 % 100 % 100 % % % 100 % 100 % 100 % 100 % % Fixed 100 % 100 % 100 % 100 % TemBreak Cat. No. XM30PB XS15CS XS15NS XS15CJ XS15NJ XH15NJ XH15PJ XE5NC XH160PJ XSNJ XHNJ XHPJ XS0CJ XS0NJ XH0PJ XS0SE XH0SE XH0PE XS630CJ XS630NJ XH630PJ XS630SE XH630SE XH630PE XS800NJ XH800PJ XS800SE XH800SE XH800PE XS1SE XS1600SE XS000NE XS0NE TL100NJ TLNJ TL0NE TL630NE TL800NE TL1NE XSND TL100EM XV0NE XV630PE XV800PE XV1NE Part C Sect. TB1 type stocked in Stocked Use XS15NS Stocked Use XH15NJ Use XH15NJ Stocked Use XH15NJ Use ENJ Use XHNJ Stocked Stocked Use S0GJ 1 ) Use XS0NJ Stocked Use XH0SE ) Use XH0SE Stocked Use XH0SE ) & 4 Stocked & 4 Stocked & 4 Use S800RJ or H800NE 1 ) ) & 4 Stocked & 4 Stocked & 4 Stocked & 4 Stocked & 4 Stocked & 4 Use XH800SE & 4 Stocked & 4 Indent & 4 Stocked & 4 Stocked & 4 Stocked & 4 Stocked Use H15NJ 1 ) Use HNJ 1 ) Use H0NE 1 ) & 4 Stocked & 4 Stocked & 4 Available indent item & 4 Refer NHP Stocked Stocked Stocked Stocked Stocked Notes: 1 ) TemBreak MCCB. This is an electrical equivalent, though check the application as the physical size of the TemBreak equivalent will be different. ) Ics rating are lower on SE/ NJ types compared to PE/ PJ types. TemBreak 1 and cross reference chart refer section 5

3 TemBreak 1 MCCBs XS15 single pole Fixed thermal and magnetic trip Current 45 C 16 A 15 A Standards AS/NZS Breaking capacity at V DC, 0 V AC XS15NS (5 ka) Ampere rating (A) pole Cat. No. XS15NS 16 1 XS15NS 0 1 XS15NS 5 1 XS15NS 3 1 XS15NS 1 XS15NS 1 XS15NS 63 1 XS15NS 80 1 XS15NS XS15NS 15 1 Dimensions (mm) Description Height XS15NS 155 Width 30 Depth 86 kg 0.5 Short circuit capacity Model I/C Voltage XS15NS 5 ka V Hz Base standards IEC BS EN Part VDE 0660 Part 1 AS/NZS CE MARK JIS C 837/JAPAN JEC 160/JAPAN Approvals ASTA/UK, Aust. standards Marine NK/JAPAN Lloyd s R/UK ABS/USA GL/GERMANY BV/FRANCE XS15NS can replace XS15CS Notes: An internal shunt trip may be mounted in an XS15/NS MCCB. TemBreak replacement S15NF. Check exact ratings and dimensions to suit your application. 3

4 TemBreak 1 MCCBs XH15 Adjustment range % of nominal rating Coordinated with Sprecher + Schuh contactors Standards AS/NZS Adjustable thermal, fixed magnetic trip XH15NJ ( ka) 3 pole Ampere rating (A) Min. Max Cat. No. XH15NJ 0 3 XH15NJ 3 3 XH15NJ 3 XH15NJ 63 3 XH15NJ XH15NJ 15 3 Bolton earth leakage module ELB 15. Dimensions (mm) Description Height XH15NJ 3 pole 155 Width 90 Depth 86 kg 1.3 Short circuit capacity Model I/C Voltage XH15NJ ka 0/415 V Hz DC use I/C 1 ) Voltage XH15NJ ka V DC Base standards IEC BS EN Part VDE 0660 Part 1 AS/NZS 60947/Aust./NZ CE MARK JIS C 837/JAPAN JEC 160/JAPAN Approvals ASTA/UK, Aust. standards Marine NK/JAPAN Lloyd s R/UK ABS/USA GL/GERMANY BV/FRANCE DNV NORWAY XH15NJ can replace XS15CJ and XS15NJ Notes: 1 ) Poles in series. Refer applications NHP. Tembreak replacement: S15GJ Check exact rating & dimensions suit your application. 4

5 TemBreak 1 MCCBs XS and XH NJ Adjustment range % of nominal current rating Standards AS/NZS Adjustable thermal, fixed magnetic trip XSNJ (5 ka) 3 pole Ampere rating (A) Min XHNJ ( ka) 3 pole Max Cat. No. XSNJ XSNJ 3 XHNJ XHNJ 3 Dimensions (mm) Description XSNJ 3 pole Height 165 Width 105 Depth 86 kg 1.85 XHNJ 3 pole Short circuit capacity Model I/C Voltage XSNJ XHNJ 5 ka ka 0 V Hz 0/415 V Hz DC use I/C 1 ) Voltage XSNJ ka V DC XHNJ ka V DC Base standards IEC BS EN Part VDE 0660 Part 1 AS/NZS 60947/Aust./NZ CE MARK JIS C 837/JAPAN JEC 160/JAPAN Approvals ASTA/UK, Aust. standards Marine NK/JAPAN Lloyd s R/UK ABS/USA GL/GERMANY BV/FRANCE DNV NORWAY Notes: 1 ) Poles in series. Refer NHP. XSNJ TemBreak replacement S160/NJ, ENJ. Check exact ratings and dimensions to suit you application. XHNJ TemBreak replacement S160GJ, SGJ. Check exact ratings and dimensions to suit you application. 5

6 TemBreak 1 MCCBs XHPJ and XH0PJ Powerful interrupting capacities Limitation of system damage Unique contact structure Adjustable thermal and magnetic trips Thermal adjustment range % of nominal current rating Standards IEC 60947/AS/NZS XHPJ and XH0PJ (65 ka) 3 pole Ampere rating (A) Min. Max. 160 (0AF) (0AF) Cat. No. XHPJ XHPJ 3 XH0PJ 0 3 Dimensions (mm) Description Height XH/0PJ 3 pole 60 Width 1 Depth kg 4.7 Short circuit capacity AC use Model Icu Ics Voltage XH/0PJ 65 ka ka 0/415 V Hz DC use 1 ) Icu Ics Voltage XH/0PJ ka V DC Base standards IEC BS EN Part VDE 0660 Part 1 AS/NZS Aust./NZ CE MARK Approvals ASTA/UK, Aust. standards Marine Lloyd s R/UK ABS/USA GL/GERMANY BV/FRANCE Notes: 1 ) Poles in series. Refer applications NHP. TemBreak replacement: S160/GJ, H160/NJ, SPE ( AF), S0GJ (0 AF) 6

7 TemBreak 1 MCCBs XS0NJ series thermal magnetic type Adjustment range % of nominal current rating Standards AS/NZS Adjustable thermal and magnetic trip XS0NJ ( ka) 3 pole Ampere rating (A) Min. Max. Cat. No XS0NJ 3 XS0NJ 0 3 Dimensions (mm) Description Height XS0NJ 3 pole 60 Width 1 Depth kg 4.7 Short circuit capacity Model I/C Voltage XS0NJ ka 0/415 V Hz DC use 1 ) I/C Voltage XS0NJ ka V DC Base standards IEC BS EN Part VDE 0660 Part 1 AS/NZS 60947/Aust./NZ CE MARK JIS C 837/JAPAN JEC 160/JAPAN Approvals ASTA/UK, Aust. standards Marine NK/JAPAN Lloyd s R/UK ABS/USA GL/GERMANY BV/FRANCE DNV NORWAY XS0NJ can replace XS0CJ Notes: 1 ) Poles in series. Refer applications NHP. TemBreak replacement S0NJ. Check exact ratings and dimensions to suit your application. 7

8 TemBreak 1 MCCBs XH0SE electronic SE Upstream Selectivity breakers SE offers enhanced selectivity 3:1 ratio between upstream & downstream MCCBs Ics rating is % of Icu I t switch to assist in obtaining total selectivity True RMS monitoring Electronic trip unit with Long, Short and Instantaneous adjustments Adjustment range 100 % of nominal current rating Standards IEC 60947/AS/NZS XH0SE (65 ka) 3 pole Ampere rating (A) Min. Max. Cat. No XH0SE 3 XH0SE 0 3 Dimensions (mm) Description Height XH0SE 3 pole 60 Width 1 Depth kg 5 Short circuit capacity AC use Model Icu Ics Voltage XH0SE 65 ka 33 ka 0/415 V Hz OCR options (factory fitted) Description Code Pretrip alarm LSIP Fault indicators FI Special LTD curves Base standards IEC BS EN Part VDE 0660 Part 1 AS/NZS Aust./NZ CE MARK Approvals ASTA/UK, Aust. standards Marine Lloyd s R/UK ABS/USA GL/GERMANY BV/FRANCE XH0SE can replace XS0SE Notes: TemBreak replacement S0GE. Check exact ratings and dimensions to suit your application. 8

9 TemBreak 1 MCCBs XS630 and XS800 thermal magnetic Adjustable range % of nominal current rating Standards AS/NZS and IEC Adjustable thermal, fixed magnetic type XS630NJ ( ka) 3 pole Ampere rating (A) Min. Max. Cat. No XS630NJ 0 3 XS630NJ XS800NJ ( ka) 3 pole Ampere rating (A) Min. Max. Cat. No XS800NJ Dimensions (mm) Description XS630NJ 3 pole XS800NJ 3 pole Height 1 ) Width Depth kg Short circuit capacity Model I/C Voltage XS630NJ XS800NJ ka ka 0 V Hz 0 V Hz DC use ) I/C Voltage XS630NJ XS800NJ ka ka V DC V DC Cross reference table Section Accessories 14 Selectivity & Cascade 14 Chassis 14 Dimensions and mounting 14 Base standards IEC BS EN Part VDE 0660 Part 1 AS/NZS JIS C 837/Japan JIS 160/Japan CE MARK Approvals ASTA (UK,AUS) Marine NK/Japan Lloyd s / UK ABS / USA GL / Germany BV / France DNV / Norway Notes: XS63ONJ can replace XS630CJ 1 ) Height excludes attached busbar. ) Poles in series. Refer applications NHP. Refer NHP for 4 pole dimensions. Magnetic only MCCBs available on request. TemBreak replacement S800NJ/RJ. 9

10 TemBreak 1 MCCBs XH630PJ and XH800PJ Thermal magnetic Powerful interrupting capacities Limitation of system damage Unique contact structure Adjustable thermal and magnetic trips Thermal adjustment range % of nominal current rating Standards AS/NZS and IEC XH630/800PJ (85 ka) 3 pole Ampere rating (A) Min. Max Cat. No. XH630PJ 0 3 XH630PJ XH800PJ Dimensions (mm) Description Height 1 ) XH630/800PJ 3 pole 73 Width 10 Depth kg 9.6 Short circuit capacity AC use Model Icu Ics Voltage XH630/800PJ XH630/800PJ 100 ka 85 ka 0 V AC 415 V AC DC use ) Icu Ics Voltage XH630/800PJ ka ka ka V DC Cross reference table Section Accessories 14 Selectivity & Cascade 14 Chassis 7 Dimensions and mounting 14 Base standards IEC BS EN Part VDE 0660 Part 1 AS/NZS CE MARK Approvals ASTA (UK,AUS) Marine Lloyd s / UK ABS / USA GL / Germany BV / France DNV / Norway Notes: 1 ) Height excludes attached busbar. ) Poles in series. Refer applications NHP. TemBreak replacements S800RJ/H800NE. 10

11 TemBreak 1 MCCBs XS and XH630/800SE Electronic SE Upstream selectivity breakers SE series provides enhanced selectivity 3:1 ratio between upstream and downstream MCCBs Ics rating is % of Icu I t switch to assist in obtaining total selectivity True RMS monitoring Electronic trip unit with Long, Short and Instantaneous adjustments Adjustment range 100 % of nominal current rating Standards AS/NZS and IEC XS630SE ( ka) 3 pole Ampere rating (A) Min. Max XH630SE (65 ka) 3 pole Cat. No. XS630SE XH630SE XS800SE ( ka) 3 pole XS800SE XH800SE (65 ka) 3 pole XH800SE Dimensions (mm) Description XS/XH630SE 3 pole XS/XH800SE 3 pole Height 1 ) Width Depth ) kg Short circuit capacity AC use Model Icu Ics Voltage XS630/800SE XH630/800SE Description Ground fault trip ka 65 ka Code LSIG 5 ka 33 ka OCR options (factory fitted) Cross reference table Section Accessories 14 Selectivity & Cascade 14 Chassis 7 Dimensions and mounting 14 0/415 V 0/415 V Base standards IEC BS EN Part VDE 0660 Part 1 AS/NZS CE MARK Approvals ASTA (UK,AUS) Marine Lloyd s / UK ABS / USA GL / Germany BV / France DNV / Norway Notes: 1 ) Height excludes attached busbar. ) Less toggle TemBreak replacement S800RE/NE. 11

12 TemBreak 1 MCCBs TL630NE, TL800NE and TL1NE Electronic Standards AS/NZS and IEC Powerful interrupting capacities Provides limitation of system damage during a fault Electronic trip unit with Long, Short & Inst. adjustments Ics = 65 to 70 ka at 415 V Adjustment range 100 % of nominal current rating True RMS monitoring I t ramp switch to assist in obtaining total selectivity Can be used for selectivity applications 3 or 4 pole types available TL630NE (15 ka) 3 pole Ampere rating (A) Min. Max TL800NE (15 ka) 3 pole Cat. No. TL630NE i TL800NE TL1NE (15 ka) 3 pole TL1NE (15 ka) 4 pole i i i TL1NE FC TL1NE 1 3FC Dimensions (mm) Description Height 1 ) Width Depth ) kg TL630/800/1NE TL1NE pole 4 pole i i TL1NE FC TL1NE 1 4FC Short circuit capacity AC use Model Icu Ics Voltage TL630NE TL630NE TL800NE TL800NE TL1NE TL1NE OCR options (factory fitted) Description Code Ground fault trip Pretrip alarm 3 ) Fault indicators 3 ) Special LTD curves 15 ka 15 ka 15 ka 15 ka 15 ka 15 ka LSIG LSIP FIP 70 ka 70 ka 70 ka 70 ka 65 ka 65 ka 0 V AC 415 V AC 0 V AC 415 V AC 0 V AC 415 V AC Cross reference table Section Accessories 14 Selectivity & Cascade 14 Dimensions and mounting 14 Base standards IEC BS EN Part VDE 0660 Part 1 AS/NZS CE MARK Approvals ASTA (UK,AUS) Marine Lloyd s / UK ABS / USA GL / Germany BV / France DNV / Norway Notes: 1 ) Height excludes attached busbar. ) Less toggle 3 ) Includes factory fitted OCR controller, specify voltage V or 110 V AC. TemBreak replacement H800NE/S1GE. Check exact ratings and dimensions to suit your application. i Available on indent only. 1

13 TemBreak 1 MCCBs XS1SE and XS1600SE electronic SE Upstream selectivity breakers SE series provides enhanced selectivity 3:1 ratio between upstream and downstream MCCBs Ics rating is 75 % of Icu I t switch to assist in obtaining total selectivity True RMS monitoring Electronic trip unit with Long, Short and Inst. adjustments Adjustment range 100 % of nominal current rating Standards AS/NZS and IEC XS1SE (85 ka) 3 pole Ampere rating (A) Min Max Cat. No. XS1SE FC XS1SE 1 3FC XS1600SE (100 ka) 3 pole XS1600SE FC XS1SE (85 ka) 4 pole Ampere rating (A) Min Max Cat. No. XS1SE FC XS1SE 1 4FC XS1600SE (100 ka) 4 pole XS1600SE FC Dimensions (mm) Description XS1SE 3 pole XS1600SE 3 pole XS1SE 4 pole XS1600SE 4 pole Height 1 ) Width Depth kg Short circuit capacity AC use Model Icu Ics Voltage XS1SE XS1600SE 85 ka 100 ka 64 ka 75 ka 0 V 0 V Cross reference table Section Accessories 14 Selectivity & Cascade 14 Chassis ) 7 Dimensions and mounting 14 OCR options (factory fitted) Description Ground fault trip Pretrip alarm Fault indicators Special LTD curves Code LSIG LSIP FI Base standards IEC BS EN Part VDE 0660 Part 1 AS/NZS CE MARK Approvals ASTA (UK,AUS) Marine Lloyd s / UK ABS / USA GL / Germany BV / France DNV / Norway Notes: 1 ) Height excludes attached busbar. ) For XS1SE only. TemBreak replacement S1000NE /S1NE/GE /S1600NE/GE. Check exact ratings and dimensions to suit your application.

14 TemBreak MCCBs DC Current type, 630 A 0 A Ampere rating (A) 1000 (800 AF) ratings to 0 A Size range A Adjustable trips Trip unit type Thermal/magnetic Magnetic only Magnetic only Magnetic only Magnetic only i i i Cat. No. ) 3 ) XS1000ND XS1ND 1 ) XS1600ND XS000ND XS0ND Cross reference Complete new range of TemBreak DC MCCBs Refer NHP Section Accessories 5 Application data Characteristic curves 6 OCR / Trip unit setup 6 Dimensions and mounting 6 Ampere frame Type Number of poles Rated current (A).In Calibrated at 45 C DC RATED OPERATIONAL VOLTAGE (Ue) (V DC) DC RATED INSULATION VOLTAGE (Ui) (V DC) DC RATED BREAKING CAPACITY [ka] IEC [Icu] IEC [Ics] 4 ) 600 V BS EN [Icu] BS EN [Ics] 4 ) 0 V CEI EN CEI EN ) 3 V V OUTLINE DIMENSIONS (mm) a d c a b c d Weight (kg) marked standard type CONNECTION AND MOUNTINGS Front Terminal screw (FCS) connect (FC) Attached flat bar (BAR) Solderless terminal (PWC) Rear Bolt stud (REB) connect (RC) Flat bar stud (REF) plugin (PM) For switchboard (PCR/PMB) For distribution board Drawout (DO) STANDARD FEATURES ON/OFF colour indication Trip button PROTECTIVE FUNCTIONS Thermal and adjustable magnetic trips Adjustable magnetic trips only 800 XS1000ND /10 0/10 30/15 / XS1ND /15 0/15 30/3 / XS1600ND /15 0/15 30/3 / XS000ND /15 0/15 30/3 / XS0ND /15 0/15 30/3 / All TemBreak thermal magnetic MCCBs can be used for DC applications Notes: 1 ) 3 pole sizes stocked. ) Mounting details for DC Application series are identical to those for the same frame size Standard series (i.e. for XS1000ND refer to XS800NJ, XS1ND and XS1600ND refer to XS1600SE, XS000ND and XS0ND refer to XS0NE) For 1 A and 1600 A DC MCCBs some internal accessories may differ from standard AC types. Information is as follows. Internal accessories are a factory fit. a) Auxiliaries and alarms Same as standard AC MCCB type b) Shunt trips are type: H438BAA 110 V DC or H439BDA 0 V DC c) Under voltage trips are types: H3776CCB 110 V DC or H3776CBB 0 V DC + barrier H3748EBA 3 ) Many accessories are common with AC types though please refer to NHP for correct Catalogue Numbers. 4 ) The time constant (L/R) of the circuit should be less than.0 ms at or below rated current, less than 7 ms for short circuit equal and below 10 ka, less than 15 ms for short circuit over 10 ka and the connection should be three poles in series. XS1000ND is a thermal magnetic type. i Supplied as standard Yes or available Not available Available on indent only. Optional specify when ordering 14

15 TemBreak MCCBs DC Current type, 630 A 0 A Ampere frame ACCESSORIES (option) CODE Internally Auxiliary switch AX, AXE (AX) (AX) (AX) (AX) (AX) mounted Alarm switch AL, ALE (AL) (AL) (AL) (AL) (AL) Shunt trip SHT Undervoltage trip UVT Externally Motor operator MOT mounted Handle Panel mounted type OHE operating Breaker mounted type OHJ mechanism Variable depth type OHH Handle extension EHA Mechanical interlock front type MIF Mechanical interlock rear type MIB Handle holder HH Handle lock HL Terminal cover front connect type TCF Terminal cover rear/plugin type TCR Interpole barriers TBA Accessories lead terminal 1 ) LTF ) LTS Door flange D.F IP 0 protection (Draw out type) IP 0 Notes: 1 ) Drawout leads, horizontally. ) Drawout leads, vertically. Supplied as standard Yes or available Optional specify when ordering Not available 15

16 TemBreak 1 Mining breakers 1000 V mining breakers TL100EM series Current rating: A Complies with IEC and Standards AS/NZS Fixed trip unit thermal magnetic Max. insulation voltage 100 V AC IEC Standard specifies that the recovery voltage during the test shall be 105% of the assigned voltage This provides an inbuilt safety factor in case of transformers being rated at 105% of the nominal voltage TL100EM V AC, 3 pole Ampere rating (A) Cat. No. TL100EM15 3K TL100EM0 3K TL100EM30 3K TL100EM 3K TL100EM 3K TL100EM60 3K TL100EM75 3K TL100EM100 3K Dimensions (mm) Description Height Width Depth 1 ) kg TL100EM Short circuit interrupting capacity (ka) AC Model I/C Voltage TL100EM TL100EM 10 ka 6.5 ka 900 V Hz 1100 V Hz Cross reference table Section Accessories 14 Dimensions and mounting 14 Installation data 7 Base standards IEC AS/NZS When TL100EM MCCBs are installed a lineside terminal cover (TL100EMLTC) MUST be used (Cover supplied with MCCB) Notes: 1 ) Less toggle. TemBreak replacement V15. Check exact ratings and dimensions to suit your application. 16

17 TemBreak 1 Mining breakers 1000 V mining breakers electronic XV Positive contact indication Type of fault indication option Fastbreak mechanism High fault rating Electronic trip unit with Long, Short and Inst adjustments Adjustment range 100% of nominal current rating True RMS monitoring I t switch to assist in obtaining total selectivity Complies with IEC test standard which specifies that the recovery voltage during the test shall be 105% of the recovery voltage This provides an inbuilt safety factor in the case of transformers being rated at 105% of the nominal voltage Standards IEC 60947/ AS/NZS Terminal screw covers provided with breakers XV0NE V AC, 3 pole 3 ) 4 ) Ampere rating (A) Min Max Cat. No XV0NE 160 3K 3 ) XV0NE 3K 3 ) XV0NE 0 3K 3 ) XV630/800PE V AC, 3 pole 4 ) XV1NE V AC, 3 pole 4 ) XV630PE 630 3K XV800PE 800 3K XV1NE 0 3K XV1NE 800 3K XV1NE K XV1NE 1 3K Dimensions (mm) Description Height Width Depth 5 ) kg XV0NE XV630PE/XV800PE 6 ) XV1NE 6 ) Short circuit interrupting capacity (ka) AC Model 1000 V 1100 V XV0NE XV630PE XV800PE XV1NE OCR options (factory fitted) Description Code Ground fault trip ) LSIG Pretrip alarm LSIP Fault indicators 1 ) FIP HI inst. models Special LTD curves Cross reference table Section Accessories 14 Dimensions and mounting 14 Installation data 7 Base standards IEC AS/NZS Notes: 1 ) Includes factory fitted OCR controller, specify voltage or 110 V AC. ) GFT unavailable for XV 0 MCCBs. 3 ) Lineside Terminal covers MUST be used for XV0 MCCBs (Ref. H14 DAB supplied with MCCB). 4 ) Clearance and installation information can be found in section. 5 ) Depth, less toggle. 6 ) Dimensions do not include attached busbar. TemBreak replacement V0/630/800/1000/1. Refer rating and dimensions to suit your application. 17

18 TemBreak 1 MCCB accessories TemBreak standard combinations of internally mounted accessories AUX Auxiliary switch ALT SHT UVT Alarm switch Shunt trip Undervoltage trip Internal accessories are NHP factory fit only handle Left pole Right pole UVT rating A. Inst type AC V AC 00 V AC V DC 4 V XM30PB XS 15PJ XS15CJ XS15NJ XH15NJ TL30F XH 160PJ XSNJ XHNJ XE5NC XV0NE XV630NE XV800NE XV1NE XS630CJ/NJ/PJ XH/XS630SE XS800NJ/PJ XH/XS800SE XS1SE XS1600SE TL630NE TL800NE TL1NE XS630NN XS800NN XS1NN XS1600NN XS000NE XS0NE XS000NN XS0NN DC 48 V i DC 60 V DC V DC V B. Time delay type AC V AC 00 V AC V SHT rating AC V AC V AC 4 V AC 48 V i i i DC 1 V DC 4 V DC 30 V DC 48 V DC 60 V DC V DC 15 V DC V Notes: i Available on indent only. 18

19 TemBreak 1 MCCB accessories Accessories to suit XS/XH 15, TL100NJ 3 ) Undervoltage trip UVT controller XS15CS/0 A with shunt trip fitted Alarm switch Internal accessories (factory fit) Description Shunt trip (1 pole) Shunt trips (, 3, 4 pole) Undervoltage trips Auxiliary switches Alarm switches Alarm & auxiliary switches 1004 V AC / 48 V DC 1 P SHT 110 V AC SHT ( V) V AC SHT (00480 V) 4 V DC SHT 48 V DC SHT 110 V DC SHT ( V) 4 V AC SHT 48 V AC SHT 1 V DC SHT 00 V DC SHT (0030) AC coil 1 ) 4 V DC coil ) V DC coil ) 48 V DC coil ) 60 V DC coil ) 110 V AC instantaneous controller V AC instantaneous controller 4 V AC instantaneous controller 110 V AC time delay controller V AC time delay controller 4 V AC time delay controller 0030 V DC controller AUX SW right hand 1 C / 3 P AUX SW right hand C / 3 P AUX SW right hand 1 C / 4 P AUX SW right hand C / 4 P AUX SW left hand 1 C AUX SW left hand C ALT SW right hand / 3 P ALT SW right hand / 4 P ALT SW left hand ALT/AUX SW right hand 1 C / 3 P ALT/AUX SW right hand 1 C / 4 P ALT/AUX SW left hand 1 C Cat. No. UXVC0001C H1935BAC H1935BBC H1935BCC H1935BDC H1935BEC H1936BAC H1936BBC H1936BDC H1936BHC H1947BAC H1947BBC H1947BCC H1948BAC H1948BBC UXUB00B UXUB0014B UXUB0015B UXUB0016B UXUB0017B UXUB0018B UXUB0037B UXXB0019D UXXB000D H383DAA H384DAA UXXB006E UXXB007E UXLB0001E H385DAA UXLB007E UXLB0003E H387DAA UXLB008E Alarm & auxiliary switch Notes: 1 ) An AC UVT controller is required for 1004 V AC. ) A DC UVT controller is needed for 0030 V DC operation. None required for 4110 V DC. 3 ) AF = Ampere frame. 19

20 TemBreak 1 MCCB accessories Accessories to suit 15 AF, TL30F, TL100NJ 1 ) Attached busbar Tunnel Clamp Terminals (Solderless terminals) Rear connect studs Plugin tulip blocks Plugin base UXMB motor operator External accessories Description Attached busbar Tunnel Clamp terminals Rear connect studs Motor operators Mechanical interlocks Handle operators Handle locks Terminal covers front connect Terminal covers rear connect Plugin breaker parts 3 pole 8 ) TemPlug Interpole barrier OCR sealing kit Pole fillers Earth leakage block Adapter kit for TO0 chassis 3 P attached busbars (6 in kit) 3 P solderless terminals (6 in kit) ) 4 P solderless terminals (8 in kit) ) 3 P rear connect studs (6 in kit) 4 P rear connect studs (8 in kit) 110 V AC motor V AC motor 110 V DC motor 3 P rear mech I/lock 4 P rear mech I/lock IP 65 rated variable depth handle, door interlocking IP 55 direct mount rotary handle 3 ) IP 65 metal variable depth handle IP 55 grey varidepth handle mm shaft T1HS escutcheon plate option: 100 mm 90 mm T pin shaft for T1HS no flexi coupling Padlock attachment for T1HP/HS mechanism T1HS handle shaft cam for fortress or Prosafe locks Handle lock non captive Padlock attachment 5 ) captive 1 ) Resin for XKA Key interlock (Fortress type) incl TFJ mechanism 4 ) 3 P FC terminal cover 4 P FC terminal cover IP 0 protection cover 6 ) Seal plate 7 ) 3 P RC terminal cover 4 P RC terminal cover Terminal and bolt Insulation plate AUX conn. block (MCCB side) 3 P tulip blocks (6 in kit) 3 P mounting base 3 P TemPlug Cat. No. for 1 only 8 ) OCR sealing kit For use with metal escutcheon covers Addon earth leakage block with pretrip alarm contacts Order one kit per breaker Cat. No. TRED0001 TXED0005A TXED0006A UXRC0011A UXRC001A UXMB0041C UXMB0057B UXMB0061C UXKB0017B UXKB0018B T1HP1XR6BNA4 TFJXU YASD T1HS1XR5GM THSESC100 THSSHAFT T1HP1PALK UXKB00A XKA LOCTITE 480 H17DAA H18DAA A1785DAA H16DAA UXPD0031A UXPD003A UXYD0007A UXYE0005A UXYC00A TXED0010A XDM3 UPX315 UXQH000B XS1CRSK XAB ELB15A TO0XS15 Rear interlock Notes: 1 ) AF = Ampere frame. ) Factory fit only. 3 ) Flush plate included. 4 ) Tech data, refer NHP. 5 ) Captive type. Resin fixing. 6 ) 6 pieces required for 3 P / 8 pieces required for 4 P. 7 ) Specify qty required (up to pieces). 8 ) A total of 4 individual barriers for 3 P, and 6 barriers required for 4 P. 0

21 TemBreak 1 MCCB accessories Accessories to suit 160 AF / AF 4 ) Undervoltage trip UVT controller Alarm switch Alarm & auxiliary switch Internal accessories (factory fit) Description Shunt trips Undervoltage trips Auxiliary switches Alarm switches Alarm & Auxiliary switches External accessories Description Attached busbars Tunnel clamp terminals (solderless terminals) 110 V AC ( V) V AC ( V) 4 V DC 48 V DC 110 V DC ( V) 4 V AC 48 V AC 1 V DC 00 V DC (0030 V) AC coil 1 ) 4 V DC coil ) V DC coil ) 48 V DC coil ) 60 V DC coil ) 110 V AC instantaneous controller V AC instantaneous controller 4 V AC instantaneous controller 110 V AC time delay controller V AC time delay controller 4 V AC time delay controller 0030 V DC controller AUX SW right hand 1 C AUX SW right hand C AUX SW left hand C ALT SW right hand ALT / AUX SW right hand 1 C 3 P attached busbars (6) 4 P attached busbars (8) 3 P solderless term (6) / XS 3 ) 4 P solderless term (8) / XS 3 ) 3 P solderless term (6) / XH 3 ) 4 P solderless term (8) / XH 3 ) Cat. No. H1937BAA H1937BBA H1937BCA H1937BDA H1937BEA H1938BAA H1938BBA H1938BDA H1938BHA H1949BAB H1949BBB H1949BCB H19BAB H19BBB UXUB00B UXUB0014B UXUB0015B UXUB0016B UXUB0017B UXUB0018B UXUB0037B H1951BAA H195BAA UXXB008B H1953BAA H1954BAA Cat. No. TXJD00B TXJD0051B H008DAB H008DBB H734DAA H734DBA Tunnel clamp terminals Notes: 1 ) An AC UVT controller is required for 1004 V AC. ) A DC UVT controller is needed for 0030 V DC operation. None required for 4110 V DC. 3 ) Factory fit only. 4 ) AF = Ampere frame. 1

22 TemBreak 1 MCCB accessories Accessories to suit 160 AF / AF 7 ) UXMB motor operator Rear interlock Interpole barriers OCR sealing kit External accessories Description Rear connection studs Motor operators Mechanical interlocks Handle operators Handle lock Terminal covers Plugin breaker parts 3 pole TemPlug Interpole barriers Pole fillers Earth leakage block OCR sealing kit 3 P rear connect studs (6) 4 P rear connect studs (8) 110 V AC motor 1 ) 0 V AC motor 1 ) V AC motor 1 ) 110 V DC motor 1 ) 3 P rear mech int. / XS 4 P rear mech nt. / XS 3 P rear mech int./ XH 4 P rear mech int./ XH IP 65 rated variable depth handle, door interlocking 1 ) IP 55 direct mount rotary handle mechanism ) IP 65 metal variable depth handle IP 55 grey varidepth handle mm shaft T1HS escutcheon plate option: 100 mm 90 mm T pin shaft for T1HS no flexi coupling Padlock attachment for T1HP/HS mechanism T1HS handle shaft cam for Fortress or Prosafe locks Handle lock non captive Padlock attachment captive 3 ) Resin for XKA Key interlock (Fortress Type) incl TFJ mechanism 8 ) 3 P FC terminal cover / XS 4 P FC terminal cover / XS 3 P FC terminal cover / XH 4 P FC terminal cover / XH IP 0 protective cover 4 ) 3 P RC terminal cover / XS 4 P RC terminal cover / XS 3 P RC terminal cover / XH 4 P RC terminal cover / XH Seal plate 5 ) AUX conn. block (MCCB side) AUX conn. block (panel side) 3 P tulip block / XS 3 P tulip block / XH 3 P mounting base 3 P TemPlug / XH only Interpole barrier / XS 6 ) Interpole barrier / XH 6 ) For use with metal escutcheon covers Addon earth leakage block with pretrip alarm (XH) Addon earth leakage block with pretrip alarm (XS) OCR sealing kit Cat. No. H66DAA H66DBA UXMB0046D UXMB0047D UXMB0058B UXMB006C UXKB0019B UXKB000B UXKB001B UXKB00B T1HP5XR6BNA4 TFJ3SU YASD3 T1HS5XR5GM THSESC100 THSSHAFT T1HP5PALK UXKB0014A XKA LOCTITE 480 H5DAB H1410DAB H6DAA H141DAA A1786DAA UXPD007B UXPD008B UXPD0033B UXPD0034B H16DAA UXYC0010A UXYB0004A TXJD0054A TXJD0058A XDM33 UPX3 UXQH000B UXQH0003B XAB3 ELBAH ELBA XSOCRSK Notes: 1 ) Add UXFD0016A when required for XHNJ & XH160PJ. ) Flush plate included. 3 ) Captive type. Resin fixing. 4 ) 6 pieces required for 3 P / 8 pieces required for 4 P. 5 ) Specify quantity required (up to pieces). 6 ) 4 pieces required for 3 P (6 pieces required for 4 P). 7 ) AF = Ampere frame. 8 ) Tech data, refer NHP.

23 TemBreak 1 MCCB accessories Accessories to suit 0 AF, XV0 Undervoltage trip UVT controller Auxiliary switch Alarm / auxiliary switch Internal accessories (factory fit) Description Shunt trip Undervoltage trip Auxiliary switch Alarm switch Alarm & auxiliary switch External accessories Description Attached busbars Tunnel clamp terminals Rear connect studs Motor operators (XMC4) 110 V AC/DC ( V) V AC ( V) 1 V DC 4 V DC 48 V DC 00 V DC (00 30 V) 4 V AC 48 V AC AC coil 1 ) V DC coil ) 4 V DC coil ) 48 V DC coil ) 60 V DC coil ) 110 V AC instantaneous controller V AC instantaneous controller 4 V AC instantaneous controller 110 V AC time delay controller V AC time delay controller 4 V AC time delay controller 0030 V DC controller AUX SW right hand 1 C AUX SW right hand C AUX SW right hand 3 C ALT SW right hand ALT/AUX SW right hand 1 C ALT/AUX SW right hand C 3 P attached busbars (6 in kit) 4 P attached busbars (8 in kit) 3 P solderless term (6 in kit) 4 P solderless term (8 in kit) 3 P RC studs (6 in kit) 4 P RC studs (8 in kit) 110 V AC motor 3 ) 110 V DC motor 3 ) 4 V DC motor 3 ) V AC motor 3 ) Motor base support Cat. No. H05BAA H06BAA H07BAA H08BAA H09BAA H10BAA H11BAA H1BAA H149BAA H1493BAA H1494BAA H1495BAA H1496BAA UXUB00B UXUB0014B UXUB0015B UXUB0016B UXUB0017B UXUB0018B UXUB0038B UXXB0004D UXXB0005D UXXB0006D UXLB0009D UXLB00D UXLB0014D Cat. No. H84DAA H85DAA H01DAB H01DBB UXRC0006C UXRC0007C UXMC0001B UXMC0003B UXMC0004B UXMC0005B UXMD0001B Attached busbar Rear connect studs Notes: 1 ) An AC UVT controller is required for 1004 V AC. ) A DC UVT controller is needed for 0030 V DC operation. None required for 4110 V DC. 3 ) Order one (1) motor base support for each XMC4 motor. 3

24 TemBreak 1 MCCB accessories Accessories to suit 0 AF, XV0 External accessories Description Cat. No. T1HP Handle operator TFJ handle operator Terminal covers 10 ) Mechanical interlocks Cable mechanical interlocks Handle operators Handle lock Terminal covers Accessory lead terminal block Plugin breaker parts 3 pole 11 ) TemPlugs 11 ) Interpole barrier OCR sealing kit 3 P mech I/lock 3 ) 3/4 P mech I/lock 4 ) 4 P mech I/lock 5 ) Interlock cable (wire) Cable interlock mechanism 6 ) IP 65 rated variable depth handle ) 14 ) IP 65 Metal variable depth handle 15 ) IP 55 direct mount rotary handle mechanism 14 ) IP 55 grey varidepth handle + 30 mm shaft T1HS escutcheon plate option: 100 mm 390 mm T pin shaft for T1HS no flexi coupling Padlock attachment for THP/HS mechanism Position indication kit for THP/HS mechanism T1HS handle shaft cam for Fortress locks Handlelock non captive Captive lock attachment (LOCTITE 480 adhesive required) Key interlock (Fortress type) incl TFJ mechanism 16 ) 3 P front connecting terminal cover busbar connect type 4 P front connecting terminal cover busbar connect type 3 P front connecting terminal cover cable connect type 4 P front connecting terminal cover cable connect type IP 0 protective cover busbar connect type 8 ) IP 0 protective cover cable connect type 8 ) 3 P rear connecting terminal cover 4 P rear connecting terminal cover Accessory lead terminal block Terminal and bolt 9 ) AUX conn block (MCCB) side AUX conn block (panel) side Mounting bolts 3 P tulip block (8) 3 P mounting base 3 P TemPlug 0 A Interpole barrier 10 ) Tamperproof cover for the OCR adjustment dials UXKC0001B UXKC000B UXKC0003B UXKC000A UXKC001B T1HPR6BNA4 YASD34 TFJ34XU T1HSR5GM THSESC100 THS0SHAFT T1HPPALK THPPOS H1956BAA XKA4 H14DAB H1414DAB H1415DAB H1416DAB A1787DBA A1788DAA UXPD0011B UXPD001A UXYD0001A UXYD000A UXYC0005A UXYB0004A TXKD003A TXKD0033A XDM43 UPX34 UXQH0004B XS0OCRSK Interpole barriers Notes: 3 ) For 3 P circuit breakers without motors. 4 ) For 4 P circuit breakers without motors or 3 P circuit breakers with motors. 5 ) For 4 P circuit breakers with motors. 6 ) Order one interlock mechanism for each circuit breaker. 8 ) 6 pieces required for 3 P / 8 pieces required for 4 P. 9 ) Specify quantity required (up to 6 pieces). 10 ) Order individually. 11 ) Not applicable to XV0NE. ) TemBreak style IP 65 rated handle. 14 ) Red/Yellow safety handles are available. 15 ) YASD handles do not have a door defeat function. 4

25 TemBreak 1 MCCB accessories Accessories to suit AF Internal accessories (factory fit) Description Cat. No. Shunt trip 110 V AC/DC H1515BAA V AC H1516BAA 1 V DC H1517BAA 4 V DC H1518BAA Undervoltage trip UVT 48 V DC 00 V DC H1519BAA H150BAA 4 V AC H151BAA 48 V AC H15BAA Undervoltage trip AC coil 1 ) HBAA V DC coil ) H14BAA 4 V DC coil ) H15BAA 48 V DC coil ) H16BAA 60 V DC coil ) H17BAA UVT controller 110 V AC instantaneous controller V AC instantaneous controller UXUB00B UXUB0014B 4 V AC instantaneous controller UXUB0015B 110 V AC time delay controller (100 ms delay) UXUB0016B V AC time delay controller (100 ms delay) UXUB0017B 4 V AC time delay controller (100 ms delay) UXUB0018B 0030 V DC controller UXUB0038B Auxiliary switch AUX SW right hand 1 C UXXB0007D AUX SW right hand C UXXB0008D AUX SW right hand 3 C UXXB0009D Alarm switch ALT SW right hand UXLB0010D Auxiliary switch Alarm & auxiliary switches ALT/AUX SW right hand 1 C ALT/AUX SW right hand C UXLB0015D UXLB0016D Fault indication Side of breaker mounted module. Add FI & contacts Electronic MCCBs only. then voltage Earth fault option. Earth fault, electronic breakers only. Add LSIG 4th CTs are optional 630 A 4th CT UXOY0001A 800 A 4th CT UXOY000A Alarm / auxiliary switch Notes: 1 ) An AC UVT controller is required for 1004 V AC. ) A DC UVT controller is needed for 0030 V DC operation. None required for 4110 V DC. 5

26 TemBreak 1 MCCB accessories Accessories to suit AF External accessories Cat. No. Cable mechanical interlock T1HP80 handle operator Handle lock (UXKB) Tunnel clamp terminals Rear connect studs Motor operators (XMC6) 7 ) Motor operators (XMD6) Mechanical interlocks Handle operators Handle extension Handle lock Terminal covers Accessory lead terminal TemPlug 3 ) Interpole barrier OCR sealing kit 3 P solderless terminals for 630 AF (6 in kit) 4 P solderless terminals for 630 AF (8 in kit) 3 P rear connect studs, 630/800 AF (6 in kit) 4 P rear connect studs, 630/800 AF (8 in kit) 110 V AC motor 110 V DC motor 4 V DC motor V AC motor Motor base support 110 V AC motor 110 V DC motor 4 V DC motor V AC motor 3 P mech I/lock rear mounting 4 P mech I/lock rear mounting Interlock cable (wire) Cable interlock mechanism 1 ) IP 65 Variable depth handle. Door interlocking (METAL) ) 6 ) IP 65 rated variable depth handle. Door interlocking ) 4 ) 5 ) IP 55 direct mount rotary handle mechanism ) 4 ) IP 55 grey varidepth handle + 30 mm shaft T1HS escutcheon plate option: 100 mm 390 mm T pin shaft T1HS no flexi coupling Padlock attachment for T1HP/HS mechanism T1HS handle shaft cam for Fortress or Prosafe locks Handle extension Handle lock non captive Captive lock attachment (LOCTITE 480 adhesive required) Key interlock (Fortress Type 1) incl TFJ mechanism ) 3 P front connecting terminal cover 4 P front connecting terminal cover IP 0 protective cover 3 P rear connecting terminal cover 4 P rear connecting terminal cover Accessory terminal block Terminal and bolt TemPlug 800 A rated Interpole barrier Tamperproof cover for the OCR adjustment dials TXLD0005A TXLD0006A UXRC0008B UXRC0009B UXMC0006B UXMC0008B UXMC0009B UXMC00010B UXMD000B H199CAC H01CAC H0CAC H03CAC UXKC0004A UXKC0005A UXKC000A UXKC00A YASD46 T1HP80R6BNA4 TFJ36XU T1HS80R5GM THSESC100 THS0SHAFT T1HP80PALK A7BAB UXKB000A XKA6 H1417DAB H1418DAB A1787DBA UXPD00C UXPD0014B UXYD0001A UXYD000A UPX3800 UXQH0004B XS630OCRSK Notes: 1 ) Order one interlock mechanism for each circuit breaker. ) Refer NHP for additional detail. 3 ) Not applicable to XV630PE/XV800PE. 4 ) Red/Yellow handles available. 5 ) Refer NHP for Fortress locks to suit XFH handles. 6 ) YASD handles do not have a door defeat function. 7 ) XMC6 motors are used on all transfer switches as standard, and require a motor base support along with the motor when ordered. XMD6 motors offer superior ON/OFF/TRIPPED status indication and can be fitted to transfer switches on request. XMD6 motors do nore require a motor base support. 6

27 TemBreak 1 MCCB accessories Accessories to suit AF, XS1, XS1600, TL630NE, TL800NE, TL1NE 3 ) Internal accessories (factory fit) Description Cat. No. Undervoltage trip UVT UVT controller Auxiliary switch Alarm / auxiliary switch Shunt trip Undervoltage trip Auxiliary switch Alarm switch Alarm & auxiliary switches Fault indication & contacts Earth fault indication. 4th CT optional 110 V AC/DC ( V) V AC (00480 V) 1 V DC 4 V DC 48 V DC 00 V DC (0030 V) 4 V AC 48 V AC AC coil 1 ) V DC coil ) 4 V DC coil ) 48 V DC ) 60 V DC ) 110 V AC instantaneous controller V AC instantaneous controller 4 V AC instantaneous controller 110 V AC time delay controller V AC time delay controller 4 V AC time delay controller 0030 V DC controller AUX SW right hand 1 C / 3 P AUX SW right hand C / 3 P AUX SW right hand 3 C / 3 P AUX SW right hand 1 C / 4 P AUX SW right hand C / 4 P AUX SW right hand 3 C / 4 P ALT SW right hand / 3 P ALT SW right hand / 4 P ALT/AUX right hand 1 C / 3 P ALT/AUX right hand C / 3 P ALT/AUX right hand 1 C / 4 P ALT/AUX right hand C / 4 P An option for all A types An option for all A types 1000 A 4th CT 1 A 4th CT 1600 A 4th CT Add then voltage Add H1197BAA H1198BAA H1199BAA H100BAA H101BAA H10BAA HBAA H104BAA H108BAA H109BAA H110BAA H111BAA H11BAA UXUB00B UXUB0014B UXUB0015B UXUB0016B UXUB0017B UXUB0018B UXUB0038B UXXB0010D UXXB0011D UXXB001D UXXB003D UXXB004D UXXB005D UXLB0011D UXLB004D UXLB0017D UXLB0018D UXLB005D UXLB006D FI LSIG UXOY0003A UXOY0004A UXOY0005A Notes: 1 ) An AC UVT controller is required for 1004 V AC. ) A DC UVT controller is needed for 0030 V DC operation. None required for 4110 V DC. 3 ) TL630NE, TL800NE, TL1NE are 1600 ampere frame MCCBs. 7

28 TemBreak 1 MCCB accessories Accessories to suit AF, TL630NE, TL800NE, TL1NE 7 ) External accessories Description Cat. No. Rear connect studs 3 P rear connect studs (6 in kit) 1 A H1959DAB 4 P rear connect studs (8 in kit) 1 A H1959DBB 3 P rear connect studs (6 in kit) 1600 A H1960DAA 4 P rear connect studs (8 in kit) 1600 A H1960DBA Cable mechanical interlock mechanism Motor operators (XMD9) 110 V AC motor 110 V DC motor 4 V DC motor H1191CAB H1193CAB H1194CAB V AC motor H1195CAB Mechanical 3 P mech I/lock / 1 A rear connect UXKC0006D interlocks 4 P mech I/lock / 1 A rear connect UXKC0007D 3 P mech I/lock / 1600 A rear connect UXKC006C 4 P mech I/lock / 1600 A rear connect UXKC007C Interlock cable (wire) UXKC000A XMD9 Motor operator (spring charged type) Handle operators Interlock mechanism 1 A cable type 1 ) Interlock mechanism 1600 A cable type 1 ) IP 65 Variable depth handle. Door interlocking (METAL) 6 ) 8 ) UXKC003B UXKC004B YASD49 IP 65 rated variable depth handle. Door interlocking ) 6 ) T1HPX6R6BNA4 IP 55 direct mount rotary handle mechanism ) 6 ) TFJ38XU IP 55 grey varidepth handle + 30 mm shaft T1HSX6R5GM T1HS escutcheon plate option: 100 mm THSESC mm T pin shaft for T1HS no flexi coupling THS0SHAFT Padlock attachment for T1HP/HS mechanism T1HPX6PALK T1HS handle shaft cam for Fortress or Prosafe locks Handle extension Handle extension A7BAB Handle lock Handle lock non captive UXKB0003A Key interlock (Fortress) incl TFJ mechanism 6 ) Terminal covers 3 P FC terminal cover / 1 H1419DAB 4 P FC terminal cover / 1600 H140DAB T1HP handle operator Accessory IP 0 protective cover 3 ) Accessory terminal block A1787DBA UXYD0001A lead terminal Terminal and bolt 4 ) UXYD000A Interpole barrier Interpole barrier 5 ) UXQH0004B OCR sealing kit Tamperproof cover for the OCR adjustment dials XS1OCRSK Notes: 1 ) Order one interlock mechanism for each breaker. ) Red/Yellow handles available. 3 ) 6 pieces required for 3 P / 8 pieces required for 4 P. 4 ) Specify quantity required (up to 6 pieces). 5 ) Individual barrier (not a set). 6 ) Refer NHP for details of locks to suit TFJ handles. Cam & lock Catalogue Numbers: Fortress locks are also available for T1HS80 T1HSX6 variable depth handles. NHP can supply a cam for the handle shaft and a lock and key. XFHSH31QKEYA: Fortress key code A XFHSH31QRHALK: Fortress shot bolt, right hand, lock code A, key not supplied. 7 ) TL630NE, TL800NE, TL1NE are 1600 ampere frame MCCBs. 8 ) YASD handles do not have a door defeat function. 8

29 TemBreak 1 MCCB accessories Accessories to suit TL100EM Internal accessories (factory fit) Earth fault Description Cat. No. Shunt trip 1 ) 110 V AC 7VF M1 V AC 7VF MB 4 V DC 7VF M7 Shunt trip 48 V DC 110 V DC 7VF M6 7VF M4 Voltage release Undervoltage trip 1 ) 110 V AC UVT V AC UVT 7UF D6B 7UF D7B 4 V AC UVT i 7UF D5B Undervoltage trip UVT 4 V DC UVT 110 V DC UVT i 7UF FD 7UF FD1 Signalling devices Auxiliary switch 1 C right hand 7XA D31B 1 C left hand 7XA D41B Auxiliary switch Signalling devices Alarm switch 7AB D11B Alarm switch Notes: 1 ) Other voltages available on request refer to NHP. i Available on indent only. 9

30 TemBreak 1 MCCB accessories Accessories to suit TL100EM External accessories Connections Description Cat. No. Tunnel clamp 3 Pole (qty 6) 7T M1 Solderless terminals terminals Rear connect studs 3 Pole bar studs (qty 6) i 7RN 3LE Terminal cover 1 ) Terminal cover Fits line or loadside (qty 1) TL100EMLTC Remote operation Motor operator 110 V AC motor 0 V AC motor i 7MB 3BA1 7MB 3BA Rear connect studs Interlocks Front 3 Pole front mechanical interlock i 7LF LE1 Mounting part i 7LF A05 Handle operators Variable depth type IP Plastic handle IP 65 Metal handle TL100EM ) TFH D YASDD XMB motor operator (small) IP 65 Plastic handle 3 ) TL100EM R6 BN TFJ handle Direct mount type (IP 55) Handle mechanism i TFJLU Accessory lead terminal TFH handle operator Accessory terminal block Accessory lead terminal block (black) i 7YD 3 TFJ handle Notes: 1 ) TL100EM MCCB comes complete with a lineside terminal cover, and a rear earth barrier as standard. ) YASD handles do not have a door defeat function. 3 ) Based on TemBreak THP handle design. THS handle type optional. i Available on indent only. 30

31 Ordering branch / agent TemBreak 1 MCCB ordering sheet Factory or NHP branch assembled items only List details below Sales order Branch sales order No. Date / / This form to be filled out either by NHP staff or purchaser. Order Form MCCB Customer Project Contact name Phone Section Deliver to Circuit designation Customer s requested delivery date / / Prepared by / / Cust. order No. Checked by / / Work order numbers Planned delivery / / Notes: Use a new form for each different configuration of MCCB & Accessories Quantity Required Series XM XE XV XS XH TL No. of poles Frame Amperes Model CJ CS NC NE NJ NN NS PB PE SE PJ Special OCR Settings: Thermal Magnetic MCCB... Thermal: Notes: Thermal Magnetic & Electronic MCCBs are generally set to maximum current settings Magnetic: Electronic MCCB... IO I1 T1 I T I3 It: ON or OFF. IP TP IG TG Options: Tick applicable boxes: Options: Tick applicable boxes: 1. Tunnel clamp terminals (set of 6 on 3 P). Rear bolt studs (set of 6 on 3 P) 3. Shunt trip volts 4. Undervoltage trip volts Instantaneous Time Delayed (fixed at 100 ms) 5. Auxiliary switch contacts 6. Alarm switch 7. Alarm/auxiliary sw. contacts 8. Motor Operator volts 9. Accessory terminal lead 10. Mechanical interlock (rear type) 11. Mechanical interlock (cable type) 1. Fortress Key interlock TFJ MCCB MTG handle Specify specific Fortress keylock no. if required _. Fault indicators (electronic MCCB only) 14. Pretrip alarm (electronic MCCB only) 15. Earth fault + 4th CT electronic MCCB 630 A & above 16. TFJ Handle (mounted on breaker) 17. XFE handle (000/0 A MCCBs) 18. Plugin set (XDM Terasaki type) 19. Handle lock (captive/glued type) 0. Fortress or Prosafe key interlock Other specific requirements: Total $ Nett each 31

32 Type Ampere frame Number of poles Outside view Notes: 3 Standard TemBreak circuit breaker 1 ) 1 Pole breaker only, XS15CS and XS15NS respectively. ) pole breaker is a 3 pole breaker with the centre pole omitted. Supplied as standard. Optional standard. Yes or available. Not available i Indent only Rated current (A).In Nominal rated current Adjustable setting range Rated current at C AC RATED INSULATION VOLTAGE (Ui) AC RATED BREAKING CAPACITY sym RMS [ka] IEC [Icu] IEC [Ics] 1100V AS/NZS 3947 [Icu] AS/NZS 3947[Ics] 1000V Notes: Rated Impulse withstand voltage V Uimp (kv) is 8kV on all XS, XE and XH MCCB s 660V 0V 4V 415V 0V 380V V AS 184 4V 415V NEMA AB1 600V 480V without Inst. V DC RATED BREAKING V CAPACITY (ka) 15V RATED SHORT TIME CURRENT RMS [ka] [Icw] DIMENSIONS (mm) a d c a b b c d Weight (kg) marked standard type CONNECTION AND MOUNTINGS front terminal screw connect (FC) attached flat bar solderless terminal (PWC) rear bolt stud connect (RC) flat bar stud plugin (PM) for switchboard for distribution board drawout (DO) STANDARD FEATURES contact indicator trip button PROTECTIVE FUNCTIONS Electronic type Adjustable LTD, STD & INST Adjustable GFT or Adjustable PTA (option) Trip indicators (option) (contacts) Thermalmagnetic type thermal and fixed magnetic trips thermal and adjustable magnetic trips adjustable thermal and fixed magnetic trips adjustable thermal and magnetic trips ACCESSORIES (option) CODE Internally auxiliary switch AUX mounted alarm switch ALT shunt trip SHT undervoltage trip UVT Externally motor operator MOT mounted external panel mounted type XFE operating breaker mounted type TFJ handle variable depth type XFH IP 65 handle variable depth type TLK extension handle mechanical interlock front type mechanical interlock rear type mechanical interlock cable type key interlock handle holder handle lock captive padlock attachment terminal cover front connect type terminal cover rear/plugin type interpole barriers accessories lead terminals OCR sealing kit Selection guide ratings XS15CS /5 14/7 18/9 18/9 14/ /3.8 10/5 14/7 18/9 18/9 5/ XS15CJ 15A 1P 1 ) P ) i 4P i min max XS15NS XS15NJ 15A 1P 1 ) P ) 4P /11 5/ 5/ 30/15 5/ /.5 5/.5 1/6 /11 5/ 5/ 30/15 5/ min max

33 33 Standard TemBreak circuit breaker Selection guide ratings 4P 15A XH15NJ /4 8/4 5/ 4/1 /5 /5 /5 85/ min max min max 1.4 5A XE5NC /5 15/7.5 15/7.5 18/9 18/9 5/ (Bar) 8/4 8/4 /11 5/ 5/ 5/ 35/18 / (Bar) 00 4P A XSNJ min max /7.5 15/7.5 5/ 4/1 /5 /5 /5 85/ (Bar) 4P A XHNJ min max ICU/ICS 16/8 16/8 /11 30/15 30/15 35/18 35/18 / (Bar) 4P 0A XS0CJ min max ICU/ICS 18/9 18/9 30/15 4/1 /5 /5 /5 85/ (Bar) 4P 0A XS0NJ i i

34 TemBreak 1 Selection guide Ratings Type Ampere frame Number of poles Outside view Notes: 1 ) Adjustable ground fault available on indent, fitted externally. ) LED indicators only or LED contacts, please specify. Supplied as standard. Optional standard. Yes or available. Not available i Available on indent only Rated current (A).In Nominal rated current Adjustable setting range Rated current at C AC RATED INSULATION VOLTAGE (Ui) AC RATED BREAKING CAPACITY sym RMS [ka] IEC [Icu] IEC 60947[Ics] 1100V AS/NZS 3947 [Icu] AS/NZS 3947[Ics] 1000V Notes: Rated Impulse withstand voltage V Uimp (kv) is 8kV on all XS, XE and XH MCCBs 0V 4V 415V 0V V without Inst. V DC RATED BREAKING V CAPACITY (ka) 15V RATED SHORT TIME CURRENT RMS [ka] [Icw] DIMENSIONS (mm) a d c a b b c d Weight (kg) marked standard type CONNECTION AND MOUNTING front terminal screw connect (FC) attached flat bar solderless terminal (PWC) rear bolt stud connect (RC) flat bar stud plugin (PM) for switchboard for distribution board drawout (DO) STANDARD FEATURES contact indicator trip button PROTECTIVE FUNCTIONS Electronic type Adjustable LTD, STD & INST Adjustable GFT or Adjustable PTA (option) Trip indicators (option) (contacts) Thermalmagnetic type thermal and fixed magnetic trips thermal and adjustable magnetic trips adjustable thermal and fixed magnetic trips adjustable thermal and magnetic trips ACCESSORIES (option) CODE Internally auxiliary switch AUX mounted alarm switch ALT shunt trip SHT undervoltage trip UVT Externally motor operator MOT mounted operating breaker mounted type TFJ handle variable depth type XFH IP 65 handle variable depth type TLK extension handle mechanical interlock front type mechanical interlock rear type mechanical interlock cable type key interlock handle holder handle lock captive padlock attachment terminal cover front connect type terminal cover rear/plugin type interpole barriers accessories lead terminals OCR sealing kit XH15PJ 15A /4 5/ 4/1 / / 85/ PowerBreaker Series Ics = ka min P max XH160PJ 160A /7.5 3/ 4/1 / / 85/ (Bar) min max XHPJ A 18/9 4/15 4/1 65/ 65/ 85/ (Bar) min max 160 XH0PJ 0A 0 ICU/ICS 18/9 30/15 4/1 65/ 65/ 85/ 5 5 (0.3 sec) (Bar) 15 4P min max

35 35 4P XH0PE 0A 0 ICU/ICS 0/10 4/1 65/ 65/ 65/ 100/ 5 5 (0.3 sec) (Bar) 1 ) ) min max P XS0SE 0A ICU/ICS 18/9 30/15 4/1 /5 /5 85/ (0.3 sec) (Bar) 1 ) ) min max P XH0SE 0A ICU/ICS 0/10 4/1 65/33 65/33 65/33 100/ 5 5 (0.3 sec) (Bar) 1 ) ) min max i i Selectivity Series SE PowerBreaker Series (cont d) 4P TL100NJ 100A /85 85/85 85/85 100/ min max P TLNJ A 160 5/5 70/70 85/85 85/85 100/100 0/ (Bar) min max P TL0NE 0A 0 ICU/ICS 5/5 70/70 85/85 85/85 100/100 0/ (Bar) 00 0 min max LimitorBreaker Series Ics = 65 85kA

36 Type Ampere frame Number of poles Outside view Notes: TemBreak 1 MCCB 1 ) Adjustable ground fault available on indent, fitted externally. Supplied as standard. Optional standard. i Yes or available. Not available Indent only Rated current (A).In Nominal rated current Adjustable setting range Rated current at C Ratings and specifications XS630CJ 630 A 3 4P min 0 max XS630NJ 630 A 800 A i 4P i 4P i min 0 max XS800NJ 800 min max AC RATED INSULATION VOLTAGE (Ui) AC RATED BREAKING CAPACITY sym RMS [ka] IEC [Icu] IEC [Ics] 1100 V AS/NZS 3947 [Icu] AS/NZS 3947[Ics] 1000 V Notes: Rated Impulse with stand voltage V Uimp (kv) is 8kV on all XS, XE and XH MCCB s 660 V 0 V 4 V 415 V 0 V 380 V V AS V 415 V NEMA AB1 600 V 480 V without Inst. V DC RATED BREAKING V CAPACITY (ka) 15 V RATED SHORT TIME CURRENT RMS [ka] [Icw] DIMENSIONS (mm) a d c a b b c d Weight (kg) marked standard type CONNECTION AND MOUNTING front terminal screw connect (FC) attached flat bar solderless terminal (PWC) rear bolt stud connect (RC) flat bar stud plugin (PM) for switchboard for distribution board drawout (DO) STANDARD FEATURES contact indicator trip button PROTECTIVE FUNCTIONS Electronic type Adjustable LTD, STD & INST Adjustable GFT or Adjustable PTA (option) 1 ) Trip indicators (option) (contacts) Thermalmagnetic type thermal and fixed magnetic trips thermal and adjustable magnetic trips adjustable thermal and fixed magnetic trips adjustable thermal and magnetic trips ACCESSORIES (option) CODE Internally auxiliary switch AUX mounted alarm switch ALT shunt trip SHT undervoltage trip UVT Externally motor operator MOT mounted external panel mounted type XFE operating breaker mounted type TFJ handle variable depth type XFH IP 65 handle variable depth type TLK extension handle mechanical interlock front type mechanical interlock rear type mechanical interlock cable type key interlock handle holder handle lock captive padlock attachment terminal cover front connect type terminal cover rear/plugin type interpole barriers accessories lead terminals OCR sealing kit ICU/ICS 16/8 16/8 5/ 30/15 35/18 4/3 45/3 / ICU/ICS 0/10 0/10 35/18 /5 /5 /5 65/33 85/ ICU/ICS 0/10 0/10 35/18 /5 /5 /5 65/33 85/

37 Type Ampere frame Number of poles Outside view Notes: 1 ) Adjustable ground fault available on indent, fitted externally. TemBreak 1 MCCB Ratings and specifications XH630PJ 630 A 4P XH800PJ 800 A 4P XH630PE 630 A 4P XH800PE 800 A 4P XS630SE XH630SE 600 A 600 A 4P 4P i ) LED indicators only or LED contacts, please specify. Supplied as standard. Optional standard. Yes or available. Not available i Indent only Rated current (A).In Nominal rated current Adjustable setting range Rated current at C min 0 max min max min max min max min max min max AC RATED INSULATION VOLTAGE (Ui) AC RATED BREAKING CAPACITY sym RMS [ka] IEC [Icu] IEC 60947[Ics] 1100 V AS/NZS 3947 [Icu] AS/NZS 3947[Ics] 1000 V Notes: Rated Impulse withstand voltage V Uimp (kv) is 8kV on all XS, XE and XH MCCBs 0 V 4 V 415 V 0 V V without Inst. V ICU/ICS 45/3 65/33 85/43 85/ 100/ 15/163 ICU/ICS 45/3 65/33 85/43 85/ 100/ 15/63 ICU/ICS 0/10 4/1 65/ 65/ 65/ 100/ 10 ICU/ICS 0/10 4/1 65/ 65/ 65/ 100/ 10 ICU/ICS 0/10 35/18 /5 /5 /5 85/43 10 ICU/ICS 0/10 4/1 65/33 65/33 65/33 100/ 10 DC RATED BREAKING V CAPACITY (ka) 15 V RATED SHORT TIME CURRENT RMS [ka] [Icw] DIMENSIONS (mm) a d c a b b c d Weight (kg) marked standard type CONNECTION AND MOUNTING front terminal screw connect (FC) attached flat bar solderless terminal (PWC) rear bolt stud connect (RC) flat bar stud plugin (PM) for switchboard for distribution board drawout (DO) STANDARD FEATURES contact indicator trip button PROTECTIVE FUNCTIONS Electronic type Adjustable LTD, STD & INST Adjustable GFT or Adjustable PTA (option) Trip indicators (option) (contacts) Thermalmagnetic type thermal and fixed magnetic trips thermal and adjustable magnetic trips adjustable thermal and fixed magnetic trips adjustable thermal and magnetic trips ACCESSORIES (option) CODE Internally auxiliary switch AUX mounted alarm switch ALT shunt trip SHT undervoltage trip UVT Externally motor operator MOT mounted operating breaker mounted type TFJ handle variable depth type XFH IP 65 handle variable depth type TLK extension handle mechanical interlock front type mechanical interlock rear type mechanical interlock cable type key interlock handle holder handle lock captive padlock attachment terminal cover front connect type terminal cover rear/plugin type interpole barriers accessories lead terminals OCR sealing kit (0.3 sec) ) 1 ) (0.3 sec) ) (0.3 sec) ) (0.3 sec) ) )

38 Type Ampere frame Number of poles Outside view Notes: TemBreak 1 MCCB 1 ) Adjustable ground fault available on indent, fitted externally. ) LED indicators only or LED contacts, please specify. Supplied as standard. Optional standard. Yes or available. Not available i Indent only Rated current (A).In Nominal rated current Adjustable setting range Rated current at C Ratings and specifications XS800SE 800 A 800 i 4P min max XH800SE 800 A 800 i 4P min max XS1SE 1 A min P max XS1600SE 1600 A 4P min max AC RATED INSULATION VOLTAGE (Ui) AC RATED BREAKING CAPACITY sym RMS [ka] IEC [Icu] IEC 60947[Ics] 1100 V AS/NZS 3947 [Icu] AS/NZS 3947[Ics] 1000 V Notes: Rated Impulse withstand voltage V Uimp (kv) is 8kV on all XS, XE and XH MCCBs 0 V 4 V 415 V 0 V V without Inst. V ICU/ICS 0/10 35/18 /5 /5 /5 85/43 10 ICU/ICS 0/10 4/1 65/33 65/33 63/33 100/ 10 ICU/ICS 5/19 45/34 65/49 65/49 85/64 100/75 15 ICU/ICS 45/34 65/49 85/64 85/64 100/75 15/94 0 DC RATED BREAKING V CAPACITY (ka) 15 V RATED SHORT TIME CURRENT RMS [ka] [Icw] DIMENSIONS (mm) a d c a b b c d Weight (kg) marked standard type CONNECTION AND MOUNTINGS front terminal screw connect (FC) attached flat bar solderless terminal (PWC) rear bolt stud connect (RC) flat bar stud plugin (PM) for switchboard for distribution board drawout (DO) STANDARD FEATURES contact indicator trip button PROTECTIVE FUNCTIONS Electronic type Adjustable LTD, STD & INST Adjustable GFT or Adjustable PTA (option) Trip indicators (option) (contacts) Thermalmagnetic type thermal and fixed magnetic trips thermal and adjustable magnetic trips adjustable thermal and fixed magnetic trips adjustable thermal and magnetic trips ACCESSORIES (option) CODE Internally auxiliary switch AUX mounted alarm switch ALT shunt trip SHT undervoltage trip UVT Externally motor operator MOT mounted operating breaker mounted type TFJ handle variable depth type XFH IP 65 handle variable depth type TLK extension handle mechanical interlock front type mechanical interlock rear type mechanical interlock cable type key interlock handle holder handle lock captive padlock attachment terminal cover front connect type terminal cover rear/plugin type interpole barriers accessories lead terminals OCR sealing kit 10 (0.3 sec) ) (0.3 sec) ) (0.3 sec) ) (0.3 sec) )

39 Type Ampere frame Number of poles Outside view Notes: 1 ) Adjustable ground fault available on indent, fitted externally. ) LED indicators only or LED contacts, please specify. Supplied as standard. Optional standard. Yes or available. Not available i Indent only Rated current (A).In Nominal rated current Adjustable setting range Rated current at C TemBreak 1 LimitorBreaker Series Ics = ka Ratings and specifications TL630NE 630 A 630 4P min max TL8000NE 800 A 800 4P min max TL1NE 1 A min P max AC RATED INSULATION VOLTAGE (Ui) AC RATED BREAKING CAPACITY sym RMS [ka] IEC [Icu] IEC 60947[Ics] 1100V AS/NZS 3947 [Icu] AS/NZS 3947[Ics] 1000V Notes: Rated Impulse withstand voltage V Uimp (kv) is 8kV on all XS, XE and XH MCCBs 0V 4V 415V 0V V without Inst. V ICU/ICS 45/34 75/57 15/70 15/70 15/70 1/1 15 ICU/ICS 45/34 75/57 15/70 15/70 15/70 1/1 15 ICU/ICS 45/34 75/57 15/65 15/65 15/65 1/1 15 DC RATED BREAKING V CAPACITY (ka) 15V RATED SHORT TIME CURRENT RMS [ka] [Icw] DIMENSIONS (mm) a d a c b b c d Weight (kg) marked standard type CONNECTION AND MOUNTINGS front terminal screw connect (FC) attached flat bar solderless terminal (PWC) rear bolt stud connect (RC) flat bar stud plugin (PM) for switchboard for distribution board drawout (DO) STANDARD FEATURES contact indicator trip button PROTECTIVE FUNCTIONS Electronic type Adjustable LTD, STD & INST Adjustable GFT or Adjustable PTA (option) Trip indicators (option) (contacts) Thermalmagnetic type thermal and fixed magnetic trips thermal and adjustable magnetic trips adjustable thermal and fixed magnetic trips adjustable thermal and magnetic trips ACCESSORIES (option) CODE Internally auxiliary switch AUX mounted alarm switch ALT shunt trip SHT undervoltage trip UVT Externally motor operator MOT mounted operating breaker mounted type TFJ handle variable depth type XFH IP 65 handle variable depth type TLK extension handle mechanical interlock front type mechanical interlock rear type mechanical interlock cable type key interlock handle holder handle lock captive padlock attachment terminal cover front connect type terminal cover rear/plugin type interpole barriers accessories lead terminals OCR sealing kit 15 (0.3 sec) ) ) (0.3 sec) ) ) (0.3 sec) ) )

40 Type Ampere frame Number of poles Outside view Notes: 1 ) Adjustable ground fault available on indent, fitted externally. ) LED indicators only or LED contacts, please specify. Supplied as standard. Optional standard. Yes or available. Not available i Indent only Rated current (A).In Nominal rated current Adjustable setting range Rated current at C TemBreak 1 Mining Series TL/XV 1000 V Ratings and specifications TL100EM 100 A NonAdjust XV0NE 100 A min max XV630/800PE 630/ min max XV1NE min A max AC RATED INSULATION VOLTAGE (Ui) AC RATED BREAKING CAPACITY sym RMS [ka] IEC [Icu] IEC 60947[Ics] 1100 V AS/NZS 3947 [Icu] AS/NZS 3947[Ics] 1000 V Notes: Rated Impulse withstand voltage V Uimp (kv) is 8kV on all XS, XE and XH MCCBs 0 V 4 V 415 V 0 V V without Inst. V (900 V) DC RATED BREAKING V CAPACITY (ka) 15 V RATED SHORT TIME CURRENT RMS [ka] [Icw] DIMENSIONS (mm) a d c a b b c d Weight (kg) marked standard type CONNECTION AND MOUNTINGS front terminal screw connect (FC) attached flat bar solderless terminal (PWC) rear bolt stud connect (RC) flat bar stud plugin (PM) for switchboard for distribution board drawout (DO) STANDARD FEATURES contact indicator trip button PROTECTIVE FUNCTIONS Electronic type Adjustable LTD, STD & INST Adjustable GFT or Adjustable PTA (option) Trip indicators (option) (contacts) Thermalmagnetic type thermal and fixed magnetic trips thermal and adjustable magnetic trips adjustable thermal and fixed magnetic trips adjustable thermal and magnetic trips ACCESSORIES (option) CODE Internally auxiliary switch AUX mounted alarm switch ALT shunt trip SHT undervoltage trip UVT Externally motor operator MOT mounted operating breaker mounted type TFJ handle variable depth type XFH IP 65 handle variable depth type TLK extension handle mechanical interlock front type mechanical interlock rear type mechanical interlock cable type key interlock handle holder handle lock captive padlock attachment terminal cover front connect type terminal cover rear/plugin type interpole barriers accessories lead terminals OCR sealing kit (Bar) 1 ) ) (630 only) ) )

41 Type Ampere frame Number of poles Outside view Notes: Supplied as standard. Optional standard. Yes or available. Not available i Indent only TemBreak 1 Nonautomatic circuit breaker Selection guide ratings XS15NN 15A XENNC XSNN XS0NN A A 0A 4P i 4P i 4P i RATINGS AC RATED OPERATIONAL VOLTAGE (V) DC AS/NZS 3947 IEC RATED SHORT CIRCUIT MAKING CAPACITY peak/ka RATED SHORT TIME CURRENT RMS [ka] DIMENSIONS (mm) a d c a b b c d Weight (kg) marked standard type CONNECTION AND MOUNTINGS front terminal screw connect (FC) attached flat bar solderless terminal (PWC) rear bolt stud connect (RC) flat bar stud plugin (PM) for switchboard for distribution board drawout (DO) STANDARD FEATURES ONOFF colour indicator trip button ACCESSORIES (option) CODE Internally auxiliary switch AUX mounted alarm switch ALT shunt trip SHT undervoltage trip 1 ) UVT Externally motor operator MOT mounted external panel mounted type XFE operating breaker mounted type TFJ handle variable depth type XFH IP 65 handle variable depth type TLK extension handle mechanical interlock front type mechanical interlock rear type handle holder handle lock terminal cover front connect type terminal cover rear connect/plugin type interpole barriers accessories lead terminal block 3 ) (1 sec) ) (1 sec) ) 6 4 (1 sec) ) (0.3 secs) ) door flange IP 0 protection plug in type Maximum switching current Utilisation Category Endurance number of operations without current number of operations with current AC DC 7 3 AC3A AC3A AC3A AC3A Notes: 1 ) For AC UVT, a UVT controller is mounted externally. ) Line side interpole barriers are supplied as standard. 3 ) Drawout leads, horizontally. 41

42 TemBreak 1 MCCB Isolators Selection guide Nonautomatic circuit breakers (Switch disconnectors) Type Ampere frame Number of poles Outside view Notes: Supplied as standard. Optional standard. Yes or available. Not available 1 ) For AC UVT, a UVT controller is mounted externally. XS630NN 630 A 4P XS800NN 800 A 4P XS1NN 1 A 4P XS1600NN 1600 A 4P i Indent only RATINGS AC RATED OPERATIONAL VOLTAGE (V) DC AS/NZS 3947 IEC RATED SHORT CIRCUIT MAKING CAPACITY peak/ka RATED SHORT TIME CURRENT RMS [ka] DIMENSIONS (mm) a d c a b b c d Weight (kg) marked standard type CONNECTION AND MOUNTINGS front terminal screw connect (FC) attached flat bar solderless terminal (PWC) rear bolt stud connect (RC) flat bar stud plugin (PM) for switchboard for distribution board drawout (DO) STANDARD FEATURES ONOFF colour indicator trip button ACCESSORIES (option) CODE Internally auxiliary switch AUX mounted alarm switch ALT shunt trip SHT undervoltage trip 1 ) UVT Externally motor operator MOT mounted external panel mounted type XFE operating breaker mounted type TFJ handle variable depth type XFH IP 65 handle variable depth type TLK extension handle mechanical interlock front type mechanical interlock rear type handle holder handle lock terminal cover front connect type terminal cover rear connect/plugin type interpole barriers accessories lead terminals door flange IP 0 protection plug in type Maximum switching current Utilisation Category Endurance number of operations without current number of operations with current AC DC (0.3 secs) AC 3A (0.3 secs) AC 3A (0.3 secs) AC 3A (0.3 secs) AC 3A

43 TemBreak 1 Application data Selectivity and Cascade tables at 0/415 V MCB to MCCB Cascade The resultant cascade level with the XH630SE (65 ka) and XHNJ ( ka) MCCBs in series is 65 ka. This means that the XH630SE will backup the XHNJ MCCB to 65 ka, which is beyond its breaking capacity of ka. Selectivity From the tables, the Selectivity level between the same two breakers, XH630SE and XHNJ connected in series will be ka. This means that for fault levels up to and including ka the XHNJ will trip before the XH630SE. Conclusion For short circuit currents up to and including ka, the XHNJ will trip before the XH630SE, therefore ensuring Selectivity. For fault levels above ka both breakers may trip, however, the XH630SE will backup the XHNJ to 65 ka. Guide XX / YY Selectivity Cascade MCB to MCCB: thermal magnetic Downstream MCB Range (A) ka (RMS) Upstream MCCB XS15CJ 18 XS15NJ 5 XH15NJ XH15PJ TL100NJ XSNJ 5 XHNJ TLNJ XS0CJ 35 XS0SE XS0NJ XH0SE 65 DTCB6 0 A 6 18/18 5/5 35/35 5/5 35/35 DTCB A 0.53 A /18 18/18 0/5 5/5 0/5 30/ 5/5 5/5 30/30 / 35/35 / / DSRCBH & DSRCB DSRCBH & DSRCB DINT10H DTCB15 63 A 0.53 A A 8015 A 0.53 A /18 18/18 18/18 4/18 18/18 0/5 5/5 0/5 4/5 5/5 5/5 30/ 5/5 4/5 30/ 5/5 5/5 5/5 15/15 5/5 30/30 / 30/30 15/15 / 30/30 35/35 30/30 10/10 35/35 30/30 / 30/30 10/10 / 30/30 / 30/30 / SAFET SRCB 63 A 1663 A 160 A /18 3/10 3/10 0/5 3/10 3/10 5/5 3/10 3/10 5/5 30/30 30/30 30/30 30/30 43

44 44 TemBreak 1 Application data TemBreak MCCBs Selectivity and Cascade tables at 0/415 V Upstream MCCB XS15CJ XS15NJ XH15NJ XH15PJ TL100NJ XH160PJ XE5NC XSNJ XHNJ XHPJ TLNJ XS0CJ XS0NJ XS0SE XH0PJ XH0SE XH0PE TL0NE XS630CJ XS630NJ XS630SE XH630PJ XH630SE XH630PE XS800NJ XS800SE XH800PJ XH800SE XH800PE XS1SE XS1600SE ka (RMS) Downstream MCCB XS0SE TL0NE XH0SE 65 XS630SE TL630NE XH630SE 65 XS800SE TL800NE XH800SE 65 TL1NE XS1SE / 5/ 35/ 35/ 35/ 5/ 15/30 15/ 5/ / 15/ 5/ 35/65 35/65 35/65 5/65 15/30 15/65 5/65 /65 / /65 /65 18/30 5/30 / / / / 18/30 5/ / 10/ 10/ 10/ 10/ 10/ 10/ 10/ 10/ 18/30 5/30 /65 /65 /65 /65 18/30 5/65 /65 10/65 10/65 10/65 10/65 10/65 10/65 10/65 10/65 / /65 18/30 5/30 / / / / 18/30 5/ / 5/ 5/ 5/ 5/ 5/ 5/ 5/ 5/ 5/ 10/ 10/ 10/ 10/ 10/ 10/ 18/30 5/30 /65 /65 /65 /65 18/30 5/65 /65 5/65 5/65 5/65 5/65 5/65 5/65 5/65 5/65 5/65 10/ 10/65 10/65 10/65 10/65 10/65 /65 18/18 5/30 / / /65 / 18/18 5/35 / /65 /65 35/4 /65 /65 /65 /65 /65 65/65 30/45 30/65 30/65 30/65 30/65 30/65 15/65 15/65 15/65 15/65 15/65 XS1600SE 85 18/18 5/30 / / /85 / 18/18 5/35 / /65 /85 35/4 /65 /65 /65 /65 /65 85/85 30/45 30/85 30/85 30/85 30/85 30/85 0/85 0/85 0/85 0/85 0/85 0/65 XS000NE /18 5/30 / / /85 / 18/18 5/35 / /65 /85 35/4 35/65 /65 /65 /65 /65 /85 35/45 35/85 30/85 30/85 30/85 30/85 35/85 0/85 0/85 0/85 0/85 35/65 XS0NE /18 5/30 / / /85 / 18/18 5/35 / /65 /85 35/4 /65 /65 /65 /65 /65 /85 35/45 35/85 30/85 30/85 30/85 30/85 35/85 0/85 0/85 0/85 0/85 35/65 35/65 XX / YY Guide Selectivity Cascade MCCB to MCCB: electronic and thermal magnetic

45 TemBreak 1 Application data TemBreak MCCBs Selectivity and Cascade tables at 0/415 V Guide XX / YY MCCB to MCCB: thermal magnetic Selectivity Thermal magnetic MCCBs only. Selectivity Cascade Upstream MCCB Downstream MCCB ka (RMS) XH15NJ XSNJ 5 XHNJ XS0CJ 35 XS0NJ XS630CJ 4 XS630NJ XS800NJ XH800PJ 85 XS15CJ 18 / 3/5 3/ 4/35 4/ 6/30 6/30 10/30 10/30 XS15NJ 5 / 3/5 3/ 4/35 4/ 6/30 6/30 10/30 10/30 XH15NJ/PJ 1/ 1/65 XE5NC 18 /5 /30 /30 /30 6/5 6/30 8/30 8/30 XSNJ 5 4/ 6/4 6/ 8/ 8/65 XHNJ 4/ 10/ 10/65 XS0CJ 35 / 6/35 6/ 6/ 6/65 XS0NJ 6/ 6/65 XS630CJ 4 / XS630NJ /85 XS800NJ /85 45

46 TemBreak 1 MCCB Technical data XS15CS, XS15NS Time/current characteristic curves XS15CJ, XS15NJ, XH15NJ, XH15NJ Time/current characteristic curves Tripping Time second minute hour Min Max Magnetic trip current Rated current (A) 16 08±4 0 60±5 5 35± ±84 50±104 6± ± ± ± ± A Magnetic trip current (A) Tripping Time second minute hour Min Max Magnetic trip current Rated current (A) Magnetic trip current (A) 0 60±5 3 40±84 6± ± ± ± A A 0, 3,, 63, 100A Percent Rated Current Percent Rated Current Ambient compensating curves Ambient compensating curves 46

47 TemBreak 1 MCCB Technical data XE5NC Time/current characteristic curves XH160PJ, XSNJ, XHNJ Time/current characteristic curves Tripping Time second minute hour Min Max Magnetic trip current Rated current (A) Magnetic trip current (A) 1± 17±3 17±3 000±4 ±4 Tripping Time second minute hour Min Max Magnetic trip current Rated current (A) 160 Magnetic trip current (A) 1760±176 7± Percent Rated Current Percent Rated Current Ambient compensating curves Ambient compensating curves 47

48 TemBreak 1 MCCB Technical data XHPJ, XS0CJ, XS0NJ, XH0PJ Time/current characteristic curves XS630CJ, XS630NJ, XH630PJ Time/current characteristic curves Ambient compensating curves Ambient compensating curves c c a a a a b a a d 48

49 TemBreak 1 MCCB Technical data XS800NJ, XH800PJ Time/current characteristic curves Ambient compensating curves 49

50 TemBreak 1 MCCB Technical data TL100EM Time/current characteristic curves TL100NJ Time/current characteristic curves Tripping Time second minute hour Magnetic trip current Rated current (A) Magnetic trip current (A) 0 60±5 3 40±84 6± ± ± Percent Rated Current Ambient compensating curves Ambient compensating curves

51 TemBreak 1 MCCB Technical data TLNJ Time/current characteristic curves Tripping Time second minute hour X5 X10 Magnetic trip current Rated current (A) 160 Magnetic trip current (A) 1600±160 0± Adjustable setting range of magnetic trip. Five stages within this range Percent Rated Current Ambient compensating curves 51

52 TemBreak 1 MCCB Technical data Microprocessor based characteristics and adjustments Characteristics The standard microprocessor based MCCB from Terasaki has the most flexible characteristics on the European market. In addition to the standard overload and short circuit protection, there are a number of options available to suit specific applications. MCCB type XV0 XS630, XH630, XV630 XS800, XH800, XV800 XS1SE, XV1 XS1600SE TL6301 XS000NE XS0NE LTD STD INST I T Ramp Pickup LED Test port PTA GFT internal LEDs external LEDs Standard on all TemBreak Microprocessor MCCBs Legend Application LTD STD INST I t RAMP Pickup LED Long time delay Short time delay Instantaneous Overload protection, True RMS Short circuit protection and selectivity Short circuit protection, fast acting Provides easier grading with downstream fuses Illuminates on LTD overload, flashes on PTA pickup Standard for all TemBreak 1 Microprocessor MCCBs Test Port Facility for TNS OCR checker for calibration checking PTA Pretrip alarm Useful for loadshedding applications GFT Ground fault trip Protection against ground faults LEDs Light emitting diodes Indication of fault for faster diagnosis Access to setting dials To adjust the settings on the microprocessor TemBreak, the protective cover seal on the front of the breaker must be broken, and the cover fixing screws removed. To adjust the individual trip settings, turn the setting dial with a flat bladed screwdriver. Align the setting required between the black dots marked on the dial. (Replacement seals are provided.) Refer diagrams on following pages. Integral leads Shunt trip Undervoltage trip Integral leads Aux switch XS1600SE Alarm switch XV0 (cover removed) Notes: Standard Optional Not available 5

53 TemBreak 1 MCCB Technical data Microprocessor based characteristics adjustments, operation and setting Standard time / current curves Each part of the characteristic curve can be independently adjusted. This unique adjustability of LTD, STD and INST enables the standard microprocessor MCCB to achieve more than 00,000 permutations of its time/current characteristic. T I1 30 T1 LTD This makes the TemBreak microprocessor range one of the most flexible on the market. TemCurve To complement this range, NHP have developed TemCurve, a circuit breaker selectivity applications software package, which contains the full range of TemBreak MCCBs on database. This software programme highlights the full benefit of having highly adjustable microprocessor MCCBs when involved with difficult selectivity problems. Time 5 10 I STD T 1.0 INST I % of I1 I Standard microprocessor adjustments The I t ramp switch, which is provided as standard, assists in discrimination with downstream fuses. With the switch off, the STD operates with a definite time characteristic, e.g.. With the switch on, the characteristic alters to a ramp,, cutting off the corner which poses a potential selectivity problem. Dial setting Available adjustments Base current setting I x In Amps LTD pickup I x I0 Amps LTD setting T (at I1 x 600 %) Secs STD pickup I x I0 Amps STD setting INST pickup T I x I0 (continuously adjustable) Secs Amps Notes: A special generator T1 setting adjustment of 15 sec (at I1 x 600 %), is also available. Please contact NHP for details. 53

54 TemBreak 1 MCCB Technical data Adjustment of tripping characteristics Electronic type Electronic models of TemBreak come standard with an 8bit microprocessor overcurrent relay (OCR). It is the OCR which provides the functions necessary for protection, while maintaining a high level of reliability. The wide OCR adjustment range allows the circuit breaker to be setup in order to trip under certain conditions. Adjustments can be made to the tripping current as well as the tripping time of the breaker. Front view of breaker Figure 1. Electronic OCR adjustments possible (after removing protective cover and seal). Adjustment method Remove the seal from the OCR adjustment cover, loosen and remove the cover fixing screws and remove the cover. To adjust the individual trip settings, turn the setting dial with a flat bladed screwdriver. LONG TIME CUR. SETTING DOTS Secure the cover and apply a new seal. Notes: Align the groove (end marked with dots) between the bands for the required setting. For example, the diagram above shows I0 = 1.0. The INST and GFT pickup currents are continuously adjustable. The ground fault trip and pretrip alarm cannot be used simultaneously in a single breaker. 54

55 TemBreak 1 MCCB Technical data Microprocessor based characteristics adjustments, operation and examples Overload adjustment The rated current of the microprocessor based TemBreak is adjusted using two current multipliers. This process achieves high accuracy adjustment from % to 100 %. These are the LTD pickup dial (I1) and the Base current (I0) selector switch. The rated current (LTD pickup) is achieved as follows: IRATED = In x I0 x I1 In the example shown on the right the rating would be: IRATED = 1 x 1.0 x 1.0 = 1 A In total there are 15 possible increments of adjustment between and 100 %, as shown below. Base current Current dial Breaker rated current a Example Settings In this example, what are all the settings in Amps? Solution IRATING LTD pickup = STD pickup = INST pickup = GFT pickup = In x I0 x I1 1 x 0.8 x 0.9 = 900 A In x I0 x I 1 x 0.8 x 4 = 00 A In x I0 x I3 1 x 0.8 x 1 = 1,000 A In x IG 1 x 0.1 = 15 A (Note that GFT is a function of In and not I0) Example Time/Current curves c c 55

56 TemBreak 1 MCCB Technical data Electronic Time/Current curves XS0, XH0, TL0NE, XV0 Time/current characteristic curves XS630, XH630, XS800, XH800, XV630, XV800 Time/current characteristic curves Overcurrent tripping characteristics CT rated current (A) (In) Base current setting (A) (I0) Long timedelay pickup current (A): (I1) Long timedelay time settings (S) (T1) Short timedelay pickup current (A): (I) Short timedelay time settings (S) (T) Instantaneous trip pickup current (A) (I3) Continuously adjustable from (IO) x (3 to 1) Pretrip alarm pickup current (A) (IP) Pretrip alarm time setting (S) (TP) Notes: 56, 0 (In) x ( ) (IO) x ( ) Nontripping at (I1) setting x 105 % and below. Tripping at 15 % and above. ( ) at (I1) x 600 % current. Setting tolerance ± 0 % (IO) x (46810) Setting tolerance ± 15 % Opening time (0.1, 0.15, 0., 0.5, 0.3) in the definite timedelay. Total clearing time is + ms and resettable time 0 ms for the timedelay setting Setting tolerance ± 0 % (I1) x (0.7, 0.8, 0.9, 1.0) Setting tolerance ± 10 % fixed definite timedelay. Setting tolerance ± 10 % Optional. Underlined values will be applied as standard ratings unless otherwise specified when ordering. Overcurrent tripping characteristics CT rated current (A) (In) Base current setting (A) (Io) Long timedelay pickup current (A): (I1) Long timedelay time settings (S) (T1) Short timedelay pickup current (A): (I) Short timedelay time settings (S) (T) Instantaneous trip pickup current (A) (I3) Continuously adjustable from (Io) x (3 to 1) Pretrip alarm pickup current (A) (IP) Pretrip alarm time setting (S) (TP) Ground fault trip pickup current (A) (IG) Continuously adjustable from (In) x (0.1 to 0.4) Ground fault trip time setting (S) (TG) Notes: 630, 800 (In) x ( ) (Io) x ( ) Nontripping at (I1) setting x 105 % and below. Tripping at 15 % and above. ( ) at (I1) x 600 % current. Setting tolerance ± 0 % (Io) x (46810) Setting tolerance ± 15% Opening time (0.1, 0.15, 0., 0.5, 0.3) in the definite timedelay. Total clearing time is + ms and resettable time 0 ms for the timedelay setting Setting tolerance ± 0 % (I1) x (0.7, 0.8, 0.9, 1.0) Setting tolerance ± 10 % fixed definite timedelay. Setting tolerance ± 10 % Setting tolerance ± 15 % Opening time ( ) in the definite timedelay. Total clearing time is + ms and resettable time is 0 ms for the timedelay settings Optional. Underlined values will be applied as standard ratings unless otherwise specified when ordering.

57 TemBreak 1 MCCB Technical data Electronic characteristics and adjustments XS1SE, XS1600SE, XS000NE, XS0NE, TL630NE, TL800NE, TL1NE & XV1 Time/current characteristic curves Overcurrent tripping characteristics CT rated current (A) (In) 1000, 1, 1600, 000, 0 Base current setting (A) (IO) (In) x ( ) Long timedelay pickup current (A): (I1) (IO) x ( ) Nontripping at (I1) setting x 105 % and below. Tripping at 15 % and above. Long timedelay time settings (S) (T1) ( ) at (I1) x 600 % current. Setting tolerance ± 0 % Short timedelay pickup current (A): (I) (IO) x (46810) Setting tolerance ± 15 % Short timedelay time settings (S) (T) Opening time (0.1, 0.15, 0., 0.5, 0.3) in the definite timedelay. Total clearing time is + ms and resettable time 0 ms for the timedelay setting Instantaneous trip pickup current (A) (I3) Continuously adjustable from (Io) x (3 to 1) Setting tolerance ± 0 % Pretrip alarm pickup current (A) (IP) (I1) x (0.7, 0.8, 0.9, 1.0) Setting tolerance ±10 % Pretrip alarm time setting (S) (TP) fixed definite timedelay. Setting tolerance ±10 % Ground fault trip pickup current (A) (IG) Continuously adjustable from (IN) x (0.1 to 0.4) Setting tolerance ± 15 % Ground fault trip time setting (S) (TG) Opening time ( ) in the definite timedelay. Total clearing time is + ms and resettable time is 0 ms for the timedelay settings Notes: Optional. Underlined values will be applied as standard ratings unless otherwise specified when ordering. 57

58 TemBreak 1 MCCB Technical data XS15CS, CJ, NS, NJ, XH15NJ, PJ and TL30F MCCBs Outline dimensions (mm) Front connected (standard) ASL: Arrangement standard line H L : Handle frame centre line Notes: XS15NS 1 pole only Drilling plan Plugin (optional) Mounting block Drilling plan Plugin (optional) Mounting block Drilling plan 58

59 TemBreak 1 MCCB Technical data TL100EM SL: Arrangement Standard Line HL: Handle Frame Centre Line Outline dimensions (mm) Front connected (standard) TL100EM Preparation of conductor Drilling plan 59

60 TemBreak 1 MCCB Technical data Outline dimensions (mm) Front connected (standard) TL100EM TL100EM, TL100NJ ASL: H L : Arrangement standard line Handle frame centre line Drilling plan Front connected TL100NJ Pan head screw Preparation of conductor Drilling plan Rear connected TL100NJ Bold stud type Drilling plan Panel cutout Panel cutout dimensions shown give an allowance of 1.0 mm around the handle escutcheon. Notes: Interpole barriers standard on TL100NJ. 60

61 TemBreak 1 MCCB Technical data XSNJ Outline dimensions (mm) Front connected (standard) Preparation of conductor ASL: H L : (optional) With terminal bars Arrangement standard line Handle frame centre line Drilling plan Breakers with terminal bars available on request. Rear connected (optional) Drilling plan Panel cutout Notes: In the standard shipment mode, terminals on both the line side and the load side are in a horizontal orientation. Plugin (optional) Mounting block Drilling plan Panel cutout dimensions shown give an allowance of 1.0 mm around the handle escutcheon. 61

62 TemBreak 1 MCCB Technical data XH160PJ and XHNJ Outline dimensions (mm) ASL: H L : Arrangement standard line Handle frame centre line Frontconnected (standard) Preparation of conductor (optional) With terminal bars Drilling plan Notes: Breakers with terminal bars available on request. Rearconnected (optional) Drilling plan Panel cutout Notes: In the standard shipment mode, terminals on both the line side and the load side are in a horizontal orientation. Plugin (optional) Details of connections Mounting block Drilling plan Panel cutout dimensions shown give an allowance of 1.0 mm around the handle escutcheon. 6

63 Outline dimensions (mm) Front connected (standard) TL5F TemBreak 1 MCCB Technical data TL5F, TLNJ Preparation of conductor ASL: H L : Arrangement standard line Handle frame centre line Drilling plan With terminal bars (optional) Front connected TLNJ Hexagonal socket head screw Preparation of conductor With Terminal Bars (optional) t=8 3 P Drilling plan Rear connected Flat bar stud Drilling plan Panel cutout Notes: In the standard selection mode, terminals on both the line side and the load side are in a horizontal orientation. Panel cutout dimensions shown give an allowance of 1.0 mm around the handle escutcheon. 63

64 TemBreak 1 MCCB Technical data XS0, XH0, XV0, XHPJ ASL: Arrangement Standard Line HL: Handle Frame Centre Line Outline dimensions (mm) Front connected (standard) Preparation of conductor Optional extension busbars Drilling plan Rear connected (optional) Drilling plan Panel cutout Notes: In the standard selection mode, terminals on both the line side and the load side are in a horizontal orientation. Panel cutout dimensions shown give an allowance of 1.0 mm around the handle escutcheon. Plugin (optional) 64

65 TemBreak 1 MCCB Technical data TL0NE Outline dimensions (mm) Front connected ASL: H L : Arrangement standard line Handle frame centre line Hexagonal socket head screw Preparation of conductor With Terminal Bars (optional) t=8 Drilling plan Rear connected Flat bar stud Drilling plan Panel cutout Notes: In the standard selection mode, terminals on both the line side and the load side are in a horizontal orientation. Panel cutout dimensions shown give an allowance of 1.0 mm around the handle escutcheon. 65

66 TemBreak 1 MCCB Technical data (630 AF) XS630, XH630 Outline dimensions (mm) Front connected (standard) 4P N M Pol Drilling plan 4P 70 4P 48 M8 15 4P 1 3 4P xx4 14 4P xx M MCCB B N XS630CJ, XS630NJ XS630SE, XH630SE Rear connected (optional) Drilling plan Plugin (optional) M8 M

67 TemBreak 1 MCCB Technical data (800 AF) XS800, XH800 ASL: Arrangement Standard Line HL: Handle Frame Centre Line Outline dimensions (mm) Front connected (standard) Drilling plan Rear connected (optional) Drilling plan Panel cutout Plugin (optional) Mounting block Panel cutout dimensions shown give an allowance of 1.0 mm around the handle escutcheon. Drilling plan Details for connection 67

68 TemBreak 1 MCCB Technical data XS1, XV1 Outline dimensions (mm) Rear connected (optional) Drilling plan Panel cutout Notes: In the standard shipment mode, terminals on both the line side and the load side are in a horizontal orientation. Panel cutout dimensions shown give an allowance of 1.5 mm around the handle escutcheon. Plugin (optional) Mounting block Drilling plan 68

69 TemBreak 1 MCCB Technical data 1600 AF, XS1600SE, TL630, TL800, TL1NE ASL: Arrangement Standard Line HL: Handle Frame Centre Line Outline dimensions (mm) Rear connected with motor operator Panel cutout Panel cutout dimensions shown give an allowance of 1.5 mm around the handle escutcheon. Drawout (optional) Drilling plan 69

Innovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20E

Innovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20E Innovators in Protection Technology TemBreak Total Protection, Complete Control Catalogue No. 05 - I0E Terasaki (Europe) Ltd Terasaki Europe Ltd was established in 97 and is located near Glasgow, Scotland

More information

Innovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20EJ

Innovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20EJ Innovators in Protection Technology TemBreak Total Protection, Complete Control Catalogue No. 0 - IEJ Mission Statement. Terasaki aims to be the best supplier of circuit breakers and associated equipment

More information

MCCB Connections, mounting and chassis systems

MCCB Connections, mounting and chassis systems MCCB Connections, mounting and chassis systems Section 6 Page MCCB Chassis NHP Chassis busbar systems overview 6-2 Quick reference table 6-2 MCCBs to suit each chassis type 6-3 XA 630 / 800 A chassis for

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker & The Ultimate Safety Breaker Molded Case Circuit Breaker www.terasaki.co.jp Catalogue No. 13!5E ! Safety Notice Carefully read instruction manual to ensure proper installation, connection, operation,

More information

Terasaki (Europe) Ltd

Terasaki (Europe) Ltd Terasaki (Europe) Ltd Terasaki Europe Ltd was established in 97 and is located near Glasgow, Scotland U.K. From head office at our 7,00 square metre facility, Terasaki Europe controls an International

More information

Power Distribution and Protection

Power Distribution and Protection Power Distribution and Protection Circuit Breakers ACB -2 MCCB - MCBs RCDs and RCBOs -76 Distribution Boards Loadcentre Assemblies -7 Panelboards -24 Arc and Surge Protection Arc Detecting Relays -58 Surge

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

OUR CUSTOMER CARE COMMITMENTS

OUR CUSTOMER CARE COMMITMENTS & TemBreak MCCBs from 12A to 3200A MCCBs for 1000V AC MCCBs for 1000V DC MCCBs with Integral RCD Switch Disconnectors Measurement and Data Communication OUR CUSTOMER CARE COMMITMENTS Quality is Guaranteed

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

18-I73E CAT REF.

18-I73E CAT REF. & www.terasaki.co.jp 1-I73E CAT REF. TABLE OF CONTENTS General 1-1 Introduction 1- General 1-3 Selection Chart 1- Ratings and Specifications -1 Air Circuit Breakers for DC350V-00V - Moulded Case Circuit

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

The Ultimate Safety Breaker

The Ultimate Safety Breaker The Ultimate Safety Breaker OUR CUSTOMER CARE COMMITMENTS Quality is Guaranteed All products supplied from this catalogue carry a guarantee against defects in materials and workmanship for a period of

More information

15-I73E CAT REF.

15-I73E CAT REF. & www.terasaki.co.jp 5-I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers

More information

14-I73E CAT REF.

14-I73E CAT REF. & www.terasaki.co.jp -I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers

More information

Optional Accessories 47-83

Optional Accessories 47-83 Optional ccessories 47-83 Internally mounted accessories 48-1 Overview 48 onnection diagrams and terminal numbers 49 Ratings 0 ombinations 1 Externally mounted accessories 2-83 Overview 2-3 Motor operators

More information

OPERATING CHARACTERISTICS

OPERATING CHARACTERISTICS TEMBREAK 2 MOULDED CASE CIRCUIT BREAKERS 16A TO 630A 1. Welcome to TemBreak 2 2. Ratings and Specifications 3. Operating Characteristics Thermal Magnetic Protection 23 Thermal Magnetic Time / Current Characteristics

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

MOULDED CASE CIRCUIT BREAKERS 16A TO 630A

MOULDED CASE CIRCUIT BREAKERS 16A TO 630A TEMBREAK 2 MOULDED CASE CIRCUIT BREAKERS 16A TO 630A 1. Welcome to TemBreak 2 2. Ratings and Specifications 3. Operating Characteristics 4. Application Data 5. Accessories 6. Installation 7. Dimensions*

More information

Circuit Breaker Selection was affected by Seventeenth Edition Amendment from the First of July 2015

Circuit Breaker Selection was affected by Seventeenth Edition Amendment from the First of July 2015 Circuit Breaker Selection was affected by Seventeenth Edition Amendment from the First of July 2015 Abstract A new compensation factor, Cmin, has been included in the UK regulation for protection from

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Molded Case Circuit Breakers Solid-state trip types

Molded Case Circuit Breakers Solid-state trip types Solidstate trip types Solidstate trip types, SA00E, 0E, 00E Features Equipped with a load current pretrip alarm Constantly monitors the load current, and outputs an alarm when the set current is exceeded.

More information

World Super Series WSS The extensive breaker series from Mitsubishi Electric

World Super Series WSS The extensive breaker series from Mitsubishi Electric MODEL PUSH TO TRIP TEST 3 P IEC60947-2 JIS C 8201-2 Ue 690VAC 00VAC 440VAC 41VAC 400VAC 380VAC 230VAC T Ir Ip Is Ts EN60947-2 40 C Icu/Ics 8/8kA 30/30kA 8/8kA MODEL POLE Ui 690VAC 0-60Hz 8kV Uimp PUSH

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

High Breaking Capacity

High Breaking Capacity Air Circuit Breaker Small Light Weight High Breaking Capacity High Ability Digital APR Safety Convenience HiAN 2000 ~ 3200AF HiAN 6 ~ 1600AF CONTENTS HiAN Type 04 - Feature 06 - Rating 08 - Selection of

More information

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Low voltage circuit breakers

Low voltage circuit breakers Super Solution North American Edition Low voltage circuit breakers Contents Overview Main characteristics Accessories Technical information Mounting & connection Characteristics curves Dimensions A-1 A-2

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits 7 Technical Data Dielectric strength Circuit Withstand voltage (at 50/60 Hz) Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

TemPower 2 Air Circuit Breaker

TemPower 2 Air Circuit Breaker TemPower 2 Air Circuit Breaker Safety, Performance, Protection, Reliability. POWER DISTRIBUTION AND PROTECTION NHP Electrical Engineering Products AUS NZ 1300 NHP NHP 0800 NHP NHP nhp.com.au nhpnz.com

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

12-I73Eb CAT REF.

12-I73Eb CAT REF. & www.terasaki.co.jp -I7Eb CAT REF. TABLE OF CONTENTS General - Outline Dimensions 5- Introduction - DC Air Circuit Breakers Outline Dimensions General - Selection Chart - AR6S, AR0S 5- AR5S, ARS 5- Ratings

More information

Section 4. Moulded Case Circuit Breakers. Page

Section 4. Moulded Case Circuit Breakers. Page Moulded Case Crcut Breakers Secton MCCB Informaton Introducton to TemBreak - to - 7 TemCurve 6-7 Chasss overvew - 8 Quck reference gude - 9 TemBreak 1 & ratngs charts - 10 to - 19 Isolator MCCBs (Non Auto)

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker BREAKER Molded Case Circuit Breaker/Earth Leakage Circuit Breaker 2 BREAKER With an improved technology and agressive invesment in R&D, DAERYUK create differentiated value for each customer in order to

More information

MITSUBISHI ELECTRIC. Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors. WSS, PSS & Super Series 3 A 1600 A. Technical Catalogue

MITSUBISHI ELECTRIC. Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors. WSS, PSS & Super Series 3 A 1600 A. Technical Catalogue Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors WSS, PSS & Super Series A 100 A Technical Catalogue 2004 Circuit Breakers Circuit Breakers The new World Super Series WSS completes the

More information

Air Circuit Breakers DH series General information

Air Circuit Breakers DH series General information General information Air circuit breakers Description The newly designed air circuit breakers have excellent features as follows: The height and depth dimensions are identical in all sizes up to 3200AF

More information

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB 1 Section Contents PAGES 1. Introduction 2-5 Salient features, internal & general appearance of Drawout ACB 2. Ratings & Specifications 6-9 Free air & enclosed thermal current ratings for AC & DC applications

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

LSIS UL MCCB & Accessory

LSIS UL MCCB & Accessory LSIS UL MCCB & Accessory UL MCCB 100/150/250/400/600/800/1200AF UL MCCB Accessory 100/150/250/400/600/800/1200AF No. Specification 100AF 150AF 250AF 400AF 600AF 800AF 1200AF 1 2 3 4 5 6 7 8 9 10 11 12

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

BULLETIN 140U. Molded Case Circuit Breakers SELECTION GUIDE

BULLETIN 140U. Molded Case Circuit Breakers SELECTION GUIDE BULLETIN 140U SELECTION GUIDE Product Overview Bulletin 140U 15 1200 A Thermal-Magnetic 15 800 A Electronic 70 1200 A LS Long Time/Short Time LSI Long Time/Short Time/High Instantaneous LSG Long Time/Short

More information

Motor Circuit Breakers C4

Motor Circuit Breakers C4 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short

More information

Molded case circuit breakers

Molded case circuit breakers Molded case circuit breakers Metasol 30F to 250F Series Type Type and Pole Rated current, In Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Frame Size(F)

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

LV & MV Circuit Breakers, Contactors & Overload Relays

LV & MV Circuit Breakers, Contactors & Overload Relays LV & MV Circuit Breakers, Contactors & Overload Relays Globalization of Technology HG-Series, has been an upgraded to better performance and great customer experience. A new premium line of modern low

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Circuit protection and control devices 0.5 to 6300 A

Circuit protection and control devices 0.5 to 6300 A Electrical distribution Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2009 m TOOLS schneider-electric.com The technical guide This international site allows you to access

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Molded Case Circuit Breakers H series General information

Molded Case Circuit Breakers H series General information General information Description Models with high breaking capacities Line protection : 15 to 800A Motor protection : 16 to 5A Molded case color : Black Type number nomenclature Series H: H 5 BA / E Q M

More information

LOW-VO L TAGE POWER DISTRIBUTION PRODUCTS

LOW-VO L TAGE POWER DISTRIBUTION PRODUCTS LOW-VO L TAGE POWER DISTRIBUTION PRODUCTS Low-voltage Magnetic Contactor Starters 662 Our Power Distribution Products are compact, easy-to-use, built with safety in mind, including the full lineup of Low-voltage.

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

Intelligent Choice for Prestigious Buildings

Intelligent Choice for Prestigious Buildings Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

Catalogue No. 10!64E.

Catalogue No. 10!64E. www.terasaki.co.jp Catalogue No. 10!6E TBLE OF CONTENTS 1. Ratings and Specifications 1-1 Molded Case Circuit Breakers zfixed thermal and fixed magnetic MCCBs 1-2 cswitch-disconnectors 1- xdjustable thermal

More information

Technical Section: Miniature Circuit Breakers

Technical Section: Miniature Circuit Breakers MCBs and Accessories Data. Calibration With CBI Hydraulic- Magnetic Miniature Circuit Breakers, there is no effect on the fixed trip point at ambient temperature ranges from -5 C to +60 C. 2. Products

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information