Air Circuit Breakers DH series General information

Size: px
Start display at page:

Download "Air Circuit Breakers DH series General information"

Transcription

1 General information Air circuit breakers Description The newly designed air circuit breakers have excellent features as follows: The height and depth dimensions are identical in all sizes up to 3200AF Incresed accessibility from the front enhances easy of installation, operation and maintenance No extra arc space required, This will assist in minimizing switchboard height and costs Very fast interruption by double break system Selective trip protective coordination functions A DH Series 2500A Selection guide Series Frame size,,,, 2500, 3200, 0, 5000, 6300 No. of poles 3, 4 Installation Fixed Available (Up to 3200AF) Draw-out Available Closing mechanism Manual spring, motor spring Tripping mechanism Shunt trip, undevervoltage trip Overcurrent Characteristics L-characteristic Available protection R-characteristic Available device rotection Long time delay Available function * Short time delay Instantanous re-trip alarm Available Ground fault Available reverse power Available N-phase protection Available Contact temp.monitoring Available * Availability of protective function differs depending on the OCR type. Comparison of breaking capacity Rated current (A) Rated breaking capacity (ka. sym.)/ Rated making current (ka. peak) Rated voltage 690V AC Rated voltage 440V AC DH DH H DH DH DH H DH A A A A 2500A 3200A 0A 5000A 6300A 50/105 65/143 75/165 85/187 55/121 85/187 65/143 85/ / /264 80/ /230 Standards (Conform to the following standards) Conforming to IEC EN AS NEMA UB No. SG3 ANSI C37.13 JIS C JEC 160 /167

2 Features Standardized basic dimenstions The height and depth dimensions are identical in all sizes to 3200A. There are four common widths or frame size, from - A, from A, 0A and A for the standard series. The panel cutout size is the same for all types of DH series ACB, which makes it easy to arrange the ACBs in switchboards. Maximum power from minimum volume was central to the design specification. With a depth of 290mm for the fixed type and 345mm for draw-out, it is one of the smallest ACBs in the world. ACBs with front connections are available off-the-shelf. Front connections are especially suitable for smaller-depth switchboards. H:460 D: 345 D: 375 D:380 W: 354 Standard type to A High breaking type to A W: to 3200A to 3200A W: 631 0A W: A Geared toward the smallest depth in the world Direct connection of the isolating main contacts to the hinges of the fixed main contacts eliminates the need for intermediate conductors. Allowing the ACBs have the world's smallest depth resulting in space saving in switchboards. More than twenty design patents have been registered for the ACB. DH Series DB series Saved Space Increased accessibility from the front It enhances ease of installation, operation, and maintenance.the double insulated design ensures that most accessories can be safely and easily installed by the user. Control, auxiliary and position switch terminals are mounted at the front on the ACB body for easy access. Due to the increased level of harmonics within the distribution network, the neutral phase is fully rated as standard. Replacement of internal parts (Removing the front cover enables replacement of internal parts.) Connection to the control circuit Manual operation No extra arc space required, vertical stacking permitted The ACB dissipates all arc energy within its unique "Double Break" arc chamber. The internal energy dissipation within the ACB allows the clearance distance of the ACB to nearby earthed metal to be zero. This will assist in minimizing switchboard height and costs. No extra arc space required Draw-out operation /168

3 Features Very fast interruption by "Double Break" system The unique "Double Break" main contact system ensures extremely fast interruption of short-circuit currents and substantially reduces main contact wear. The internally symmetrical "Double Break" structure allows reverse power connection. No clamp screws used for the main circuit contact units There are no clamp screws or flexible leads in the main circuit contact units. This substantially enhances the durability of the main circuit contact units and improves the reliability in ON-OFF operation. Isolating main contact Fixed main contact Moving main contact Enhanced selectivity Fuji is so concerned about selectivity that all our protection relays have 'LSI' characteristics as standard. This provides an adjustable time delay on overload (L) and also the l2t ramp characteristic (S). As shown, these are essential to provide selectivity when grading with other protective devices such as downstream fuses and upstream relays. The standard 'LSI' curve provides more than five million combinations of unique time current characteristics. Zone selective interlocking is available to provide zero time delay selectivity. As the rated breaking capacity is identical to the rated shorttime withstand current full selectivity can be achieved. Replacement of the main contacts The fixed and moving main contacts can easily be replaced in the field, thus prolonging the life on the circuit breaker. Changing each pole takes around minutes. t 3 2 L 1 L : Long time delay S : Short time delay I : Instantaneous LSI ACB LI ACB 1 BS142/IEC R IDMT relay EI curve 50A MS= 1.0, TMS= kV 500kVA Z = 5% S 4kV 2 IEC DH12 / A I 3 BS 88/ IEC A Fuse switch erformance Rated breaking current (at V AC) Type and rated current With INST trip unction With ST delay trip function (Without INST trip/mcr function) DH08 DH12 DH16 DH20 A A A A DH12H A DH16H A DH20H A DH25 DH A 3200A DH16 A DH20 A DH A DH A DH40 0A DH A DH A 65kA 80kA 85kA 100kA 100kA 120kA Rated short-time withstand current (for 1 sec.) Note: If the ACB is DH-H type or DH- type without INST trip/mcr function, the rated breaking capacity will decrease down to the rated latching current. /169

4 Features provides positive protection for electric power systems. is equipped with an RMS sensing over-current release (OCR) having a wide range of protection functions and capabilities. Optimum protective coordination Why use a separate panel mounted protection relay when you can have all the benefits of I.D.M.T. protection integral to the ACB? Fuji ACB is available with a choice of flexible protection curves to assist in selectivity applications. All these curves are user definable and comply with IEC Standard transformer and generator protection characteristics are also available. AGR-L Industrial & transformer protection AGR-R Characteristics to IEC AGR-S Generator protection t I 0.02 t It I 2 t=s.i. I 3 t=v.i. I 4 t=e.i. Inverse Definite Minimum Time (I.D.M.T.) S.I. Standard Inverse V.I. Very Inverse E.I. Extremely Inverse I Overload protection Adjustable from % of rated current. True r.m.s detection up to the 19th harmonic, a distant vision for the competition who rarely see past the 7th. Neutral protection for all those Triple-N harmonics, such as 3rd, 9th and th. Also in case we forgot to mention, a "Thermal memory" as standard! Two channel pre-trip alarm function (S-characteristic) * 1 This function can be used to monitor and switch on additional power backup to feed critical circuits. For example, the function can be set so that when a pre-trip alarm is activated, an emergency generator starts to ensure a constant supply. This feature is only available on some AGR21 OCR models with a generator "S" characteristic. N-phase protection function (optional) In 3-phase, 4-wire systems that contain harmonic distortion, the 3rd harmonic may cause large currents to flow through the neutral conductor. The N-phase protection function prevents the neutral conductor from sustaining damage or burnout due to these large currents. Available in all OCRs except for generator "S" characteristic types. Reverse power trip function(s-characteristic) * 1 (The first-ever feature for ACBs) This feature provides additional protection when paralleling generators. The AGR21 OCR for generator protection with the reverse power trip function, negates the need for installation and wiring in an external reverse power relay. This feature is available using an AGR21 OCR with a generator "S" type characteristic only. Ground fault trip function This function eliminates external relays to provide a ground fault protection to TN-C or TN-S power distribution systems on the load side. Ground fault protection on the line side is also available as an option. Reverse phase protection function This function detects the negative-phase current occurring due to reverse phase or phase loss and precents burnout of a motor or damage to equipment. Contact temperature monitoring function (optional) * 2 This function monitors the temperature of the ACBs main contacts. An alarm indicates when the temperature exceeds 5C. Continuous monitoring of the contact temperature provides valuable input for preventative and predictive maintenance programs. Advanced L.C.D display, Over Current Relay The AGR-31B OCR comes standard with an LCD display. It can monitor and indicate phase currents, voltages, power, energy, power factor, frequency, and more. For features, refer to page /185. Standard OCR with adjustment dial Type AGR-11B Standard OCR with LCD Type AGR-21B,22B Enhanced OCR with LCD Type AGR-31B * 1 : Available for type AGR-22BS, 31BS. * 2 : Available for type AGR-22B, 31B OCR. /170

5 Type number nomenclature DH 08 3 H X - M 11BLAL F 1 Basic type 2 Frame size 08: A 12: A 16: A 20: A 25: 2500A 30: 3200A 40: 0A 50: 5000A 60: 6300A ➂ Number of poles 3: 3-pole 4: 4-pole ➃ Breaking capacity class Blank: Standard H: High : Super High ➄ Installation : Fixed (Up to 3200A) X: Draw-out with cradle Q: Draw-out with cradle & shutter ➅ Closing mechanism T: Manual-spring M: Motor-spring ex. M = 100V DC 7 Overcurrent release device 11BLAL: Standard (LT, ST, INST/MCA) 11BLGL: Std. lus GF (For details, see page /182.) 8 Tripping device F: Shunt trip (AVR-1C) ex. F = 100V DC R1: Undervoltage trip/instantaneous (AUR-1CS) R2: Undervoltage trip/500ms Time delay (AUR-1CD) * If a capacitor extractor is used, the rated voltage of the voltage extractor is 48 V. Refer to page /177. Applied standard IEC EN AS NEMA ANSI 9Detailed specifications Specify any additional requirements, such as international standards compliance, special environmental usage, or accessories, when ordering. Also clearly indicate the applicable standards, main circuit voltage, and breaking current. See the tables below. ex. IEC 440V AC 65kA Ordering code IEC EN AS NEMA ANSI Optional accessories Auxiliary switch (4DT) Auxiliary switch (10DT) Auxiliary switch (7DT) for general 4DT, for low level circuits 3DT Auxiliary switch (10DT) for general 7DT, for low level circuits 3DT OFF (Open) padlock Automatic closing spring release device Capacitor trip device Control circuit safety shutter osition switches Test jumper Mis insertion protection device Breaker fixing bolts Door interlock Key lock Key interlock Mechanical interlock Manual reset device I55 cover Control circuit terminal cover Earthing device Arc barrier Door flange Draw-out storage handle Main circuit safety shutter adlocking unit for main circuit safety shutter Lifting plate Special environment specification Ordering code Tropical uses Tropical Extremely cold use Extremely cold storage -40 C operating -25 C Anti-corrosion treatment Anti-corrosion Ordering code Auxiliary switch (4DT) Auxiliary switch (10DT) Auxiliary switch 4DT + 3DT Auxiliary switch 7DT + 3DT OFF (Open) padlock Automatic closing spring release device AQR-1 Control circuit safety shutter ALR- Test jumper Mis insertion protection device Breaker fixing bolts Door interlock Key lock Key interlock Mechanical interlock Manual reset device I55 cover Control circuit terminal cover Earthing device Arc barrier Door flange Draw-out storage handle Main circuit safety shutter adlocking unit for main circuit safety shutter Lifting plate External accessories CT for neutral line to A frame CT for neutral line to 0A frame ower transformer Lifter OCR checker Ordering code CW80-40LS EC160-40LS TSE-30M AWR-1F (DH08 to DH30), AWR-2F (DH08 to DH40) ANU-1 /171

6 Specifications, standard types Frame size A A A A 2500A 3200A 0A 5000A 6300A Basic type DH08 DH12 DH16 DH20 DH25 DH30 DH40 DH50 DH60 No. of poles * 3 * Rated current (A) * 1 * 2 IEC, EN, AS, JIS (Max.) NEMA, ANSI Rated current of the neutral pole (A) Rated primary current of overcurrent tripping device (ICT) (A) (For general feeder circuit use) Rated insulation voltage (Ui) (V, 50/60Hz) * 5 Rated operational voltage (Ue)(V, 50/60Hz)* Rated breaking capacity (ka, sym.)/ Rated making current (ka, peak) IEC, EN, AS, JIS [ICS=ICU] 690V AC * 7 50/105 65/143 75/165 85/ V 65/143 85/ V 65/143 85/ / /264 NEMA, ANSI 600V AC 42/ /1 65/ V 50/1 65/ / V 65/ / /230 Installation Fixed type Draw-out type with cradle X Draw-out type with cradle and shutter Q Main circuit terminal connection Fixed type Vertical terminal Horizontal terminal Front terminal Drow-out type Vertical terminal Horizontal terminal Front terminal Rated impulse withstand voltage (Uimp) (kv) 12 Rated short time withstand current 1 sec (Icw) (ka, rms ) 3 sec Rated latching current (ka, rms ) Total fault clearing time (s) Closing time Spring charging time 10 (s) max. Closing time 0.08 Dimensions(mm) Fixed type a b b c a c d d Drow-out type a b b c d a c d Mass (kg) For draw-out type X Notes: Available Not available Replace the mark in the type number by the pole number code 3-pole: 3 4-pole: 4 Replace the mark in the type number by the installation code Fixed: Draw-out with cradle: X Draw-out with cradle and shutter: Q Standard Available on request * 1 At ambient temperature of 40 C. * 2 Rated current at standard terminal connection. See page /202 for other terminal connection. * 3 The 2-pole ACBs are similar to 3-pole types except that the center pole contacts and conductors are omitted. * 4 If there is no phase-n protections, an IT system cannot be used for a 4-pole breaker. * 5 V AC applies to IEC and JIS C * 6 690V AC applies to IEC and JIS C * 7 Cannot be used for an IT distribution system. /172

7 Specifications, high breaking types Frame size A A A A A 2500A 3200A Basic type DH12 H DH16 H DH20 H DH16 DH20 DH25 DH30 No. of poles * Rated current (A) * 1 * 2 IEC, EN, AS (Max.) NEMA, ANSI JIS Rated current of the neutral pole (A) Rated primary current of overcurrent tripping device (ICT) (A) (For general feeder circuit use) Rated insulation voltage (Ui) (V, 50/60Hz) * 4 Rated operational voltage (Ue)(V, 50/60Hz)* Rated breaking capacity (ka, sym.)/ Rated making current (ka, peak) IEC, EN, AS, JIS [ICS=ICU] 690V AC 50/121 85/ V 80/ /220 NEMA, ANSI 600V AC 42/ /1 480V 65/ / V 80/ /230 Installation Draw-out type with cradle X Draw-out type with cradle and shutter Q Main circuit terminal connection Drow-out type Vertical terminal Horizontal terminal Front terminal Rated impulse withstand voltage (Uimp) (kv) 12 Rated short time withstand current 1 sec (Icw) (ka, rms ) 3 sec Rated latching current (ka, rms ) Total fault clearing time (s) 0.03 Closing time Spring charging time 10 (s) max. Closing time 0.08 Dimensions(mm) a Drow-out type b b a c d c d Mass (kg) For draw-out type X Notes: Available Not available Replace the mark in the type number by the pole number code 3-pole: 3 4-pole: 4 Replace the mark in the type number by the installation code Draw-out with cradle: X Draw-out with cradle and shutter: Q Standard Available on request * 1 At ambient temperature of 40 C. * 2 Rated current at standard terminal connection. See page /202 for other terminal connection. * 3 The 2-pole ACBs are similar to 3-pole types except that the center pole contacts and conductors are omitted. * 4 V AC applies to IEC and JIS C * 5 690V AC applies to IEC and JIS C If the ACB is DH-H type or DH- type without INST trip/mcr function, the rated breaking capacity will decrease down to the rated latching current. /173

8 Appearance (Example of draw-out type equipped with full accessories) Auxiliary switch terminals ON-OFF operation counter Control circuit terminals Draw-out cradle ON-OFF indicator Over-current release OFF button Spring charge indicator Spring charging handle ON button Draw-out handle insertion hole osition padlock osition indicator Internal construction Control circuit terminals Charging motor Closing coil Main circuit terminal Isolating main contact Fixed main contact Closing spring Arc chamber Closing mechanism Molded insulating cover Moving main contact Measuring CT ower CT Draw-out arm /174

9 Mounting Draw-out type This type of ACB consists of a breaker body and a draw-out cradle. The breaker body can be moved within or removed from the draw-out cradle that is fixed in the switchboard. There are four breaker body positions: CONNECTED, TEST, ISOLATED, and DRAW-OUT. The switchboard panel door can be kept closed in the CONNECTED, TEST, and ISOLATED positions ( shut-in three positions ). Note: On the position counter, an abbreviated form CONN is used instead of CONNECTED. 1. Connected position osition indicator TEST ISOLATED CONN RELEASE BUTTON Fixed type (standard series only) This type of ACB has no draw-out cradle and is designed to be directly mounted in the switchboard. Connection methods Main circuit terminals Three(3) types of main circuit terminal arrangements are available: vertical terminals, horizontal terminals, and front connections. Different types of terminal arrangements can be specified for the line and load sides. Unless otherwise specified by the user, horizontal terminals are given to types DH08, DH12 and DH16 ACBs on both the line and load sides, and vertical terminals to DH20, DH25, DH30 and DH40. For DH40, only vertical terminals available. For High breaking series (H, type), vertical terminals are standard and horizontal terminals are optional, and front connections are not available. The breaker applicable maximum rated current derated depending on the connection method. Both the main and control circuits are connected for normal service. 2. Test position osition indicator TEST ISOLATED CONN RELEASE BUTTON Horizontal terminals The main circuit is isolated and the control circuits are connected. This position permits operation tests without the need for opening the switchboard panel door. 3. Isolated position osition indicator Vertical terminals Front terminals TEST ISOLATED CONN RELEASE BUTTON Both the main and control circuits are isolated. The switchboard panel door does not need to be opened. 4. Draw-out position Control circuit terminals Control circuit terminals are front located to allow easy wiring/ access. The terminal blocks (for auxiliary switches, position switches, and control circuits) are positioned on the top of the ACB front panel and can be accessed from the front for wiring. M4 screw terminals are available. Screw terminals The breaker body is fully withdrawn from the draw-out cradle. /175

10 Closing method With ACB, there are two kinds of closing methods; manual charging type and motor charging type. Manual charging type With manual charging type ACB, the closing springs are charged manually by means of the spring charging handle. The ON/OFF operation of ACB is performed by ON/OFF buttons on the ACB. Charging the closing springs The closing springs are charged manually by pumping the spring charging handle. Closing the ACB ressing the ON button on the ACB closes the ACB. Opening the ACB ressing the OFF button on the ACB opens the ACB. The ACB cannot be closed as long as the OFF button is pressed. Motor charging type With motor charging type ACB, the closing springs are charged by a motor. The ON/OFF operation of ACB is performed remotely. The ACB is also equipped with a manual charging mechanism to facilitate inspection. and maintenance work. The electronized control circuit promises optimum control to the charging of the closing spring and ACB ON/OFF operation. Charging the closing springs The closing springs are automatically charged by a motor. When the closing springs are released with the ACB turned on, they are automatically charged again by the motor in preparation for the next ON operation. Closing the ACB Turn on the remote ON switch to close the ACB. As the antipumping mechanism is equipped, even if the ON switch is turned on continuously, the ACB's closing operation is performed only once. When the ACB has to be closed again, turn off the ON switch to reset the anti-pumping mechanism, turn on the ON switch after the closing springs charge completed. If the ON and OFF signals are simultaneously given to the ACB, the ON signals are ignored. Opening the ACB To open the ACB remotely, use the shunt trip device (see page /177), or the undervoltage trip device (see page /178). Operation power supply Rated Applicable voltage range (V) voltage (V) CHARGE/ ON operation OFF operation * AC AC AC AC AC AC DC DC DC DC DC DC DC Operation power supply ratings Motor inrush Motor steady-state current (peak) (A) current (A) Closing command current (peak) (A) Step-down transformer (separately installed) The maximum rated voltage applicable to the operation power supply is 240V AC. If higher voltage has to be applied, a step-down transformer is needed. The following step-down transformers are available as options. Rated control voltage V AC TSE-30M V AC TSE-30M M4 62 Transformer Type Capacity Voltage ratio VA 300VA 450/220V 380/220V Note: * 1 For the ratings of the shunt trip device, see page / Earth terminal 4-6U /176

11 Tripping devices Continuous rating shunt trip device The continuous-rating shunt trip device allows the ACB to be opened when an external protection relay against overcurrent or reverse power is activated. Because of its continuous rating, the device can also be used to provide an electrical interlock to the ACB. When an AGR-11 OCR is fitted or no OCR is fitted, continuous rating shunt trip and undervoltage trip can not be fitted to the same ACB. Shunt trip rating (Continuous rating type) Rated Operational eak excitation Normal Opening time Type voltage voltage current current (max.) (V) (V) (A) (A) (ms) 100 AC AC AC AC AC AC AC AC AC 4242 AC AC AC AVR1C 24 DC DC DC DC DC DC DC DC DC DC DC DC DC 4242 DC Capacitor trip device In using with the continuous rating shunt trip device, the capacitor trip device can be used to trip the ACB within a limited period of 30 sec if large voltage drop occurs due to an power (AC) failure or short-circuit. The rated voltage of the voltage extractor must be 48 V DC. When the continuous rating shunt trip device is used with capacitor trip device, NO contact of auxiliary switch of ACB should be connected in series, otherwise, the internal damage may occur. Operation check using test jumper is not allowed. Capacitor trip rating Type Rated voltage Operatiional voltage range Rated frequecy Rated voltage of shunt trip used ower consumption AQR V AC 70 to 110% of rated voltage 50/60Hz 48V DC 100VA Control circuit B (OEN) or OCRy etc. Dimensions, mm 2ø6.5 Mounting holes 10 Shunt trip AVRIC B A ower supply 100V to 120V AC Neon lamp N ower switch Capacitor trip *1 Auxiliary switch User Wiring *1: Use auxiliary switch for capacitor trip /177

12 Undervoltage trip device (UVT) The undervoltage trip device (UVT) trips the ACB when the control voltage drops below the opening voltage. When the control voltage is restored to the pick-up voltage, the ACB can be closed. The pick-up voltage is fixed to 85% of the rated voltage. The UVT consists of a tripping mechanism and an undervoltage trip control device. The trip control device is available in two types: AUR-ICS and AUR-ICD. Type AUR-ICS provides an instantaneous trip to the ACB when the control voltage drops below the opening voltage. Type AUR-ICD provides a delayed trip to the ACB when the control voltage remains below the opening voltage for at least 500 ms. Adding a pushbutton switch (with normally opened contacts) between terminals 24 and 30 allows the ACB to be tripped remotely. The undervoltage trip device is builtin the ACB unit. AC undervoltage trip control circuit AC power supply Control circuit *1 B(OEN) or OCRy etc. UVT coil *1 Tripping signal is 48 VDC/5 ma. Apply tripping signal for at least 80 ms. Undervoltage trip Ratings Type of UVT RatedVoltage Opening ick-up Coil Excitation ower Consumption (VA) Control Device 50/60Hz (V) Voltage (V) Voltage (V) Current (A) Normal Reset AUR-1CS 100 AC AUR-1CD 110 AC AC AC AC AC AC AC AC DC * DC * DC * *Available soon. Contact Fuji for the details. /178

13 Overcurrent trip device (OCR) The AGR series of overcurrent trip device (OCR) featuring high reliability and multiple protection capabilities is available for DH series. Controlled by an internal 8-bit microprocessor, the OCR provides reliable protection against overcurrent. The OCR range is divided into three groups: L-characteristic, R-characteristic (both for general feeder) and S-characteristic (for generator protection). Each group consists of: Type AGR-11B : Standard OCR with adjustment dial Type AGR-21B, 22B : Standard OCR with L.C.D. Type AGR-31B : Enhanced OCR with backlit L.C.D. Optional protection functions of the OCR include those against ground fault, earth leakage, undervoltage and reverse power. re-trip alarm function can also be installed. Types of tripping functions 1. Adjustable long time-delay trip function (LT) Effectctive value (RMS) detection used to accurately read through distorted waveforms. In addition to the standard L and S-characteristics, the R- characteristic is available in five types for long time-delay trip. The R-characteristic can be used to give selective tripping coordination with e.g., fuses. (See page /170.) Hot-start mode (applicable to L-characteristic of AGR-21B, 31B) In the hot-start mode, when overcurrent occurs in a load state, the circuit breaker operates in a shorter amount of time as compared with operation in the cold-start mode. The hot-start mode is suitable to protect motors and wires from thermal damage. The cold-start is set at factory default. Hot-start mode 2. Adjustable short time-delay trip function (ST) Ramp characteristic has been provided in addition to definite time-delay trip characteristic. The ramp characteristic gives coordinative protection with downstream circuit breakers or fuses properly. In type AGR-L and AGR-R OCRs, the definite time characteristic is activated when the load current is % or more of the rated current [In] (500% or more of the rated current [In] for AGR-S). The definite time-delay trip characteristic and ramp characteristic are selectable with a switch. The ST trip function is set to the definite time-delay trip characteristic at factory shipment. Operating time Ramp characteristic curve (L or R-characteristic) 2.5 I sd Operating time Cold-start curve Hot-start curves Current ➀When the OCR is set to start operation at 50% of the rated current, its operating time in HOT start mode is approx. 80% of that in COLD start mode. ➁When the OCR is set to start operation at 75% of the rated current, its operating time in HOT start mode is approx. 60% of that in COLD start mode. ➂When the OCR is set to start operation at 100% of the rated current, its operating time in HOT start mode is approx. 20% of that in COLD start mode. ➀ ➁ ➂ % % Current 3. Adjustable instantaneous trip function (INST/MCR) The INST trip function trips the ACB when the short circuit current exceeds the pickup current setting, irrespective of the state of the ACB. The making current release (MCR) trips the ACB when the short circuit current exceeds the pickup current setting during closing operation. After the ACB is closed, the MCR is locked and kept inoperative. The INST and MCR are switch-selectable for AGR-21B, 22B and 31B. (AGR-11B is INST only, MCR is not selectable.) Note) The MCR needs the control power. If the control power is lost, the MCR provides the INST trip function only. 4. Adjustable pre-trip alarm (TA) The pre-trip alarm function provides an alarm signal via the alarm contact (1NO-contact) when the load current exceeding a predetermined value lasts for a predetermined time. A 2 -channel pre-trip alarm function is available for S-characteristic. This function can be used to adjust feeding to loads according to their priority. The pre-trip alarm is automatically reset when the load current drops to the predetermined value. Note that this function needs the control power. t sd /179

14 5. Ground fault trip function (GF) The peak value sensing is used (the residual current of each phase is detected). The GF pickup current can be set between 10% and 100% of the CT rated primary current [I CT ]. <Ramp characteristic is added> The ramp and definite time characteristics are switch selectable. The GF trip function comes into operation with the definite time characteristic when the load current reaches 100% or more of the CT rated primary current [I CT ]. The GF trip function is factory set to the definite time characteristic. When using a 3-pole ACB in a 3-phase, 4-wire system, be sure to use an optional CT for neutral line. (See page /196.) Note 1: The GF trip function comes usually with operation indications (LED and contact output). If you need nothing but ground fault indication without a ground fault tripping operation, specify at the time of ordering. Note 2: Restricted and unrestricted ground fault protection REF is available as option. This enables to protect against ground fault on the line side of ACB. 6. Reverse power trip function (RT) (For AGR-22B and AGR-31B only) The RT function protects 3-phase generators running in parallel against reverse power. The RT pickup current can be set in seven levels: 4% through 10% of the generator rated power. If the rated main circuit voltage exceeds 250 VAC, a stepdown power transformer is needed. When ordering the ACB, state the step-down ratio of the transformer you will use. 7. N-phase protection function (N) This N function is available on 4-pole ACBs and prevents the neutral conductor from suffering damage or burnout due to overcurrent. The N trip pickup current can be set between 40% and 100% of the OCR rated primary current for L and R- characteristics or of the generator rated current for S- characteristic. It is factory set to a value specified at the time of ordering. Note 1: The N trip function comes usually with operation indications (LED and contact output). The N trip pickup current setting is shared by the LT trip function. Note 2: The HOT start mode is available for AGR-21B and AGR-31B. The operating time for the N trip function is linked to that for the LT trip function. 8. Undervoltage alarm function (UV) (For AGR-22B and AGR-31B only) This function monitors the main circuit voltage, and gives an alarm on the LCD and an output signal via an alarm contacts when the voltage drops below the setting voltage. The alarm is activated when the main circuit voltage drops below the setting voltage (selectable from 40%, 60% or 80% of the rated main circuit voltage [Vn]), and is deactivated when the main circuit voltage rises to the recovery setting voltage (selectable from 80%, 85%, 90% or 95% of the rated main circuit voltage [Vn]). If the rated main circuit voltage exceeds 250 VAC, a stepdown power transformer is needed. When ordering the ACB, state the step-down ratio of the transformer you will use. Note 1: The undervoltage alarm function is disabled unless the main circuit voltage has once risen to the recovery setting voltage or higher. Note 2: If the undervoltage alarm function is used in conjunction with the undervoltage trip device (see page /178), an alarm may occur after the ACB trips open depending on the alarm setting voltage. / Contact temperature monitoring function (OH) (For AGR-31B only.) The HEAT function prevents the ACB from suffering damage due to overheat. It monitors the temperature of the ACB main contacts, and gives an alarm on the LCD and an output signal via the alarm contact (1NO-contact) when the temperature exceeds 5 C. The alarm can be manually reset when the temperature drops to a normal temperature. If you want to set the threshold temperature to a lower value, contact Fuji. This function needs the control power. Note 1: "Alarm" or "Trip" can be selected. 10. Reverse phase protection function (NS) (For AGR-21B and AGR-31B only) This function detects the negative-phase current occurring due to reverse phase or phase loss and prevents burnout of a motor or damage to equipment. The protection setpoint ranges from 20% to 100% of the main circuit rated current [In]. 11. Zone interlock (Z) (For AGR-22B and AGR-31B only) The zone-selective interlock capability permits tripping of the ACB upstream of and nearest to a fault point in the shortest operating time, irrespective of the short time delay trip time setting, and minimizes thermal and mechanical damage to the power distribution line. NON setting and fail-safe feature 1. NON setting Setting a trip pickup current setting dial to the NON position allows you to render the corresponding protection function inoperative. Dials having the NON position include LT, ST, INST/MCR, and GF. Appropriate NON setting will be a useful means for optimum selectivity. 2. Fail-safe feature The OCR has a fail-safe mechanism in case setting dials are improperly set to the NON position. If the ST and INST trip pickup current setting dials are both set to NON, the fail-safe mechanism will activate the INST trip function to trip the ACB when a fault current equal to or more than 16 times the rated current [I n ] flows through the ACB. If the ST and MCR trip pickup current setting dials are both set to NON, the fail safe mechanism will activate the ST delay trip function to trip the ACB when a fault current equal to or more than 10 times (5 times for generator protection) the rated current [I n ] flows through the ACB. Field test or facility Type AGR-21B/22B/31B OCRs are equipped with a field test function to verify the long time delay, short time delay, instantaneous and ground fault trip features without the need for tripping of the ACB. To check type AGR-11B, use the type ANU-1 OCR checker (optional).

15 Operation indication function 1. Indication via single contact (AGR-11B) When the LT, ST, INST/MCR, or GF trip function is activated, an output is generated via 1NO-contact. The 1NO-contact will turn off after 40ms or more. A self-hold circuit is needed. 2. Indication via individual contacts (AGR-21B, 22B, 31B) When the LT trip, ST trip, INST/MCR trip, GF trip, RT, NS, REF, UVT, pre-trip alarm, or contact temperature monitoring function is activated, LCD will indicate their operation individually and output is generated via the corresponding contact. The OCR also has a self-diagnostic feature that monitors the internal tripping circuits. If detecting any fault in the circuits, this feature turns on the system alarm indicator. The control power is needed. Operation indications : Self-hold (Note 1) : Auto-reset : status indication : Not applicable rotective characteristic L/R-characteristic Function LCD Contact LTEN ST (Note 4) INST/MCR GF (Ground fault) 3. Contact ratings 3-1. Contact ratings of Trip indicator and Spring change indicator Voltage Switch contact ratings (A) (V) Resistive load Inductive load 250 AC DC DC DC Contact ratings for other contacts Voltage (V) Current (A) 1. Single contact 2. Individual contacts Resistive load Inductive load Resistive load Inductive load 250 AC DC DC DC OH (Contact temperature monitoring) (Note 2) NS (Reverse phase) REF (Line side GF) Trip indication *1 RT (Reverse power trip) TA (retrip alarm) TA2 (retrip alarm) (Note 3) UV (Undervoltage alarm) Spring charge indication System alarm Note 1: To reset the operation indication, press the button on the OCR. Note 2: Only one function can be selected from OH, NS, REF or trip indication. Selection of two or more functions involves manual connection of their control circuits (custom configuration). Contact Fuji for details. Note 3: Only one function can be selected from TA2, UV or spring charge indication. Selection of two or more functions involves manual connection of their control circuits (custom configuration). Contact Fuji for details. Note 4: Motion indication contacts are commonly used for ST and INST/MCR. *1: A switch is used to indicate the ACB has been tripped. This switch is activated whenever the off button of the overcurrent trip device, shunt drip device or undervoltage trip device is pressed. /181

16 Combination of overcurrent tripping device and indicator Division Application Type number LCD rotection function Dial adjustment type Standard LCD type Enhanced LCD type General feeder protection General feeder protection Generator protection General feeder protection Generator protection *7 11BLAL 11BLGL 21BLS 21BLG 21BRS *5 21BRG *5 21BSS 22BSR 31BLS 31BLG 31BRS *5 31BRG *5 31BSS 31BSR Multi indication *6 Amperage indication only Long time delay LT Short time delay ST Instantaneous or Making current release Note: *1 Only one function is selectable from AT2, UV and spring charge indicator. If you wish to select more than one function, the control circuit will be manually linked to special model. lease contact FUJI. *2 The GF function is not available when the CT rated primary current [ICT] is 200A or less. *3 When the main circuit voltage exceeds 250V, a step-down transformer is necessary. *4 Only one function is selectable from REF, OH, NS, and trip indicator. If you wish to select more than one function, the control circuit will be manually linked special model. lease contact FUJI. *5 You can select a R characteristic from the following 5 protective characteristics. I 0.02 T IT I 2 T I 3 T I 4 T *6 hase current, line voltage, and power can be indicated. See page /185 for details. *7 Overcurrent trip device type INST MCR re-trip alarm TA TA2 *1 Groumd fault GF *2 *a *b Optional ex. AGR - 11BL - AL- * a AGR-11BL-AL: Overcurrent trip device only * b 11BLAL: ACB with the overcurrent trip device Spring charge indication: Spring charge, Trip indication: Trip indicator U: Undervoltage alarm Z: Zone interlock S: Reverse phase protection O: Contact temperature monitoring 5 C R: Ground fault protection on line side N: N-phase protection : re-trip alarm 2 Ordering information Specify the following: 1. Type number 2. Applied standard 3. Main circuit voltage and breaking capacity 4. Optional accessories for main device and OCR 5. Voltage of each device 6. External accessories /182

17 :Standard :Optional Reverse power RT *3 N-phase protection N Gruond fault on line side REF *4 Contact monitoring OH *4 Reverse phase protection NS *4 Zone interlock Z Output indication Single contact Individual contact Spring charge indicator *1 Trip indicator *4 Undervoltage alarm UV *1*3 Field test function Control power Not required Not required Required Required Required Required Required Required Required Required Required Required Required Required Note: When AGR-11B OCR with single-contact indication is activated, the corresponding operation LED indicator is momentarily ON or OFF. But the LED indicator is kept ON when the protection function is checked with the optional OCR checker. If the control power is not supplied or is lost, each function operates as follows: LT, ST, INST, RT GF MCR Operates normally. Operates normally. When the CT rated primary current [ICT] is less than A and the GF pick-up current is set to 10 %, the GF becomes inoperative. Operates as INST. TA 1-channel Is inoperative. LED indicator on OCRs with single-contact indication Is momentarily on or off. Contact output from OCRs with single-contact indication Turns off after 40 ms or more. Contact output from OCRs with individual contact indication Is inoperative. LCD No display Field test facility Is inoperative. /183

18 General view AGR-11BL OCR (with L-characteristics) Setting item 1. Rated current 2. Long time delay trip pickup current (continuous) 3. N-phase protection trip pickup current (continuous) 4. Long time delay/n-phase protection trip timing 6. Short time delay trip pickup current 7. Short time delay trip timing 8. Short time delay trip I 2 t mode 9. Instantaneous trip pickup current 11. Ground fault trip pickup current 12. Ground fault trip timing 13. Ground fault trip I 2 t mode 16. CT rated primary current display-only field 17. Factory-set rated current display-only field /184

19 AGR-21BL-G OCR Button symbols and their meanings LCD MENU button SET button Whole LCD screen Cross button ENT button S : ress the SET button using a pointed tool such as the tip of a pen. M : ress the MENU button. : ress the up key of the cross button. : ress the down key of the cross button. : ress the right key of the cross button. : ress the left key of the cross button. E : ress the ENT button. CT rated primary current Rated current (factory set) AGR-31BL-G OCR 1. Button symbols and their meanings Same as above. LCD MENU button SET button Whole LCD screen Cross button ENT button 2. Monitoring various data on L.C.D. OCR can monitor, hase current (A) of I1, I2, I3 and their max. peak current Current (A) of IN, Ig Line voltage (V) of V12, V23, V31 and their max. peak voltage (or, hase voltage (V) of V1N, V2N, V3N and their peak voltage) Active power max. (kw) Demand active power max. (kw) ower factor (cos ø) Electric energy (kwh/ MWh/ GWh) Frequency (Hz) Trip history Fault current is monitored, and the operation cause is indicated on LCD and via individual contacts. Note : The supply voltage to the OCR for indicating the main circuit CT rated primary current voltage or power must not exceed 250 VAC. If the main circuit voltage exceeds 250 VAC, a step-down power transformer is needed. Rated current (factory set) When ordering the ACB, state the step-down ratio of the transformer you will use. 3. Gives the system alarm with number on the LCD for the following abnormal function. Trip function fail MHT circuit break /185

20 Characteristics of overcurrent trip device For general feeder circuit/l-characteristic (Type AGR-11BL, 21BL, 31BL) rotection Setting range * : Default setting function Adjustable long time ick-up current IR (A) InX ( NON), 6 steps delay trip LT Non-tripping at IR X 1.05 or less Tripping between over 1.05IR and 1.2IR or less Time delay tr (s) ( ) at 600% X IR, 9 steps Tolerance of tr (%) ±% +0ms -0ms Adjustable short time ick-up current ISd (A) InX ( NON), 10 steps delay trip ST Tolerance of ISd (%) ±% Time delay tsd (ms) Relay time (ms) , 6steps Resettable time (ms) Total fault clearing time (ms) Adjustable instantaneous ick-up current Ii (A) InX ( NON), 9 steps trip INST or MCR Tolerance of Ii (%) ±20% Adjustable pre-trip ick-up current I1 (A) In X ( ), 6 steps alarm TA Tolerance of I1 (%) ±7.5% Time delay t1 (s) ( ) at I1 or more, 10 steps Tolerance of t1 (%) ±% +100ms -0ms Adjustable ground fault ick-up current Ig (A) ICT X ( NON), 8 steps trip GF Tolerance of Ig (%) ±20% Time delay tg (ms) Relay time (ms) , 6 steps Resettable time (ms) Total fault clearing time (ms) Ground fault trip on ick-up current [I REF ] (A) [I CT ] x ( NON), 8 steps line side REF Current setting tolerance (%) ±20% (AGR-21B, 31B only) Time-delay (s) Inst Neutral phase ick-up current IN (A) ICT X ( ) Factory set to a user-specified value protection Non-tripping at 1.05 IN or less function N Tripping range: Between over 1.05IN and 1.2IN or less Time delay tn (s) Long time delay (LT) trip at 600% of IN Tolerance of tn (%) ±% +0ms -0ms Reverse phase ick-up current [I NS ] (A) [In] x ( ), 9 steps protection NS Current setting tolerance (%) ±10% (AGR-21B, 31B only) Time-delay [t NS ] (s) At 0% current of [Ins], , 10 steps Time-delay tolerance (%) ±20% +0ms -0ms Undervoltage alarm Recovery setting voltage (V) [Vn] x ( ), 4 steps UV Recovery voltage tolerance (%) ±5% (AGR-31B only) Setting voltage (V) [Vn] x ( ), 3 steps Setting voltage tolerance (%) ±5% Time delay (s) , 10 steps Time delay tolerance (%) ±5% +100ms -0ms Control power 100 to 120V AC 100 to 125V DC 24V DC 200 to 240V AC ) common 200 to 250V DC ) common 48V DC ) common ower consumption: 5VA /186

21 DH20 DH25 DH30 DH40 DH50 DH60 DH12H DH16H DH20H DH16 DH20 DH25 DH30 Values of [ICT] and [In] 11BL, 21BL, 31BL Type CT rated Rated current [In] (A) primary current [ICT] [ICT] [ICT] (A) DH DH12 DH x x [ICT] x [ICT] x Remarks There are no difference by terminal structure and safety standards There are no difference by terminal structure and safety standards There are no difference by terminal structure and safety standards IEC, JIS NEMA, ANSI / Vertical terminals NEMA, ANSI / Horizontal terminals, Front terminals There are no difference by terminal structure and safety standards IEC, JIS NEMA, ANSI / Vertical terminals NEMA, ANSI / Horizontal terminals, Front terminals Vertical terminals IEC, JIS / Front terminals IEC, JIS / Horizontal terminals NEMA, ANSI / Horizontal terminals, Front terminals Vertical terminals Horizontal terminals, Front terminals IEC, JIS NEMA, ANSI IEC, JIS IEC, JIS There are no difference by terminal structure and safety standards IEC, JIS NEMA, ANSI / Vertical terminals NEMA, ANSI / Horizontal terminals IEC, JIS NEMA, ANSI / Vertical terminals NEMA, ANSI / Horizontal terminals There are no difference by terminal structure and safety standards There are no difference by terminal structure and safety standards Vertical terminals Horizontal terminals Vertical terminals Horizontal terminals /187

22 rotection characteristics Operating time second minute hour GF current setting range N-phase protection current setting range LT current setting range TA current setting range ST current setting range INST current setting range Max ms ms Min. 100ms The ST trip characteristic shown in the figure applies when the ramp characteristic select switch is in the OFF position % of OCR rated primary current [ I CT ] % of rated current [ I n ] /188

23 Characteristics of overcurrent trip device For general feeder circuit/r-characteristic (Type AGR-21BR, 31BR) rotection function Setting range Select one from among I 002 T, IT, I 2 T, I 3 T, and I 4 T by LCD. Adjustable long time ick-up current IR (A) InX ( NON), 6 steps delay trip LT Non-tripping at IR X 1.05 or less Tripping between over 1.05IR and 1.2IR or less Time delay tr (s) Tolerance of tr (%) * : Default setting ( ) at 300% X IR, 8 steps ±20% +0ms -0ms Adjustable short time ick-up current ISd (A) InX ( NON), 10 steps delay trip ST Tolerance of ISd (%) ±% Time delay tsd (ms) Relay time (ms) , 6 steps Resettable time (ms) Total fault clearing time (ms) Adjustable instantaneous ick-up current Ii (A) InX ( NON), 9 steps trip INST or MCR Tolerance of Ii (%) ±20% Adjustable pre-trip ick-up current I1 (A) In X ( ), 6 steps alarm TA Tolerance of I1 (%) ±7.5% Time delay t1 (s) ( ) at I1 or more, 10 steps Tolerance of t1 (%) ±% +100ms -0ms Adjustable ground fault ick-up current Ig (A) ICT X ( NON), 8 steps trip GF Tolerance of Ig (%) ±20% Time delay tg (ms) Relay time (ms) , 6 steps Resettable time (ms) Total fault clearing time (ms) Ground fault trip ick-up current [I REF ] (A) [I CT ] x ( NON), 8 steps on line side REF Current setting tolerance (%) ±20% Time-delay (s) Inst Neutral phase ick-up current IN (A) ICT X ( ) Factory set to a user-specified value protection Non-tripping at 1.05 IN or less function N Tripping between over 1.05IN and 1.2IN or less Time delay tn (s) Long time delay (LT) trip at 300% of IN Tolerance of tn (%) ±20% +0ms -0ms Reverse phase ick-up current [I NS ] (A) [In] x ( ), 9 steps protection NS Current setting tolerance (%) ±10% Time-delay [t NS ] (s) At 0% current of [Ins], , 10 steps Time-delay tolerance (%) ±20% +0ms -0ms Undervoltage alarm Recovery setting voltage (V) [Vn] x ( ), 4 steps UV Recovery voltage tolerance (%) ±5% (AGR-31B only) Setting voltage (V) [Vn] x ( ), 3 steps Setting voltage tolerance (%) ±5% Time delay (s) , 10 steps Time delay tolerance (%) ±5% +100ms -0ms Control power 100 to 120V AC 100 to 125V DC 24V DC 200 to 240V AC ) common 200 to 250V DC ) common 48V DC ) common ower consumption: 5VA /189

24 DH20 DH25 DH30 DH40 DH50 DH60 DH12H DH16H DH20H DH16 DH20 DH25 DH30 Values of [ICT] and [In] 21BR, 31BR Type CT rated Rated current [In] (A) primary current [ICT] [ICT] [ICT] (A) DH DH12 DH x x [ICT] x [ICT] x Remarks There are no difference by terminal structure and safety standards There are no difference by terminal structure and safety standards There are no difference by terminal structure and safety standards IEC, JIS NEMA, ANSI / Vertical terminals NEMA, ANSI / Horizontal terminals, Front terminals There are no difference by terminal structure and safety standards IEC, JIS NEMA, ANSI / Vertical terminals NEMA, ANSI / Horizontal terminals, Front terminals Vertical terminals IEC, JIS / Front terminals IEC, JIS / Horizontal terminals NEMA, ANSI / Horizontal terminals, Front terminals Vertical terminals Horizontal terminals, Front terminals IEC, JIS NEMA, ANSI IEC, JIS IEC, JIS There are no difference by terminal structure and safety standards IEC, JIS NEMA, ANSI / Vertical terminals NEMA, ANSI / Horizontal terminals IEC, JIS NEMA, ANSI / Vertical terminals NEMA, ANSI / Horizontal terminals There are no difference by terminal structure and safety standards There are no difference by terminal structure and safety standards Vertical terminals Horizontal terminals Vertical terminals Horizontal terminals /190

25 rotection characteristics Operating time second minute hour GF current setting range N-phase protection current setting range I 4 t I 3 t I 0.02 t LT current setting range TA current setting range ST current setting range INST current setting range I 4 t I 3 t I 0.02 t ms ms 100ms The ST trip characteristic shown in the figure applies when the ramp characteristic select switch is in the OFF position % of OCR rated primary current [ I CT ] % of rated current [ I n ] /191

26 Supplied accessories ONOFF operation counter The ON-OFF operation counter is a mechanical 5-digit readout that shows the number of ON-OFF operations of the ACB. Counter readings serve as a guide for maintenance or inspection. ON-OFF button cover An ON-OFF button cover (supplied as standard) prevents inadvertent or unauthorized operation of the ON or OFF button. It can be locked with up to three padlocks with 6mm dia. hasp. adlocks are not supplied. Auxiliary switches The 7DT auxiliary switches operate during the ACB ON/ OFF operation. Connections to the switches are made via screw terminals. The auxiliary switches for draw-out type ACBs operate in the CONNECTED and TEST positions. The auxiliary switches for ACBs conforming to marine use rules which operate in the CONNECTED position only. Draw-out handle Auxiliary switch ratings Category For general use Voltage Resistive Inductive AC: cos ø 0.3 load (A) load (A) DC: L/R V AC V AC V DC V DC 1 1 Notes * 1 : The chattering of NC-contacts due to ON/OFF operation of the ACB should be less than 20 ms. * 2 : Do not supply different voltages to contacts of a switch. osition padlock lever Using the position padlock lever prevents the breaker body from inadvertently being drawn out. The position padlock lever in the pulled-out position locks the breaker body in the CONNECTED, TEST, or ISOLATED position. Up to three padlocks (with 6mm dia. hasp) can be installed. /192

27 Optional accessories Auxiliary switches The auxiliary switches operate during the ACB ON/OFF operation. Connections to the switches are made via screw terminals. The auxiliary switches for draw-out type ACBs operate in the CONNECTED and TEST positions. The auxiliary switches for ACBs conforming to marine classification society s rules operate in the CONNECTED position only. The auxiliary switches are available for general use and for microload. Auxiliary switch arrangement For general use For microload 4DT 4DT 3DT 10DT 7DT 3DT Auxiliary switch ratings Voltage V AC V AC 30V DC V DC Resistive load (A) For general use Inductive load (A) AC: cos ø 0.3 DC: L/R 0.01 Resistive load (A) Inductive load (A) For microload AC: cos ø 0.6 DC: L/R Min. applicable load 5V DC 1mA Notes 1: The chattering of NC-contacts due to ON-OFF operation of the ACB should be less than 20 ms. Notes 2: Do not supply different voltages to contacts of a switch. Key lock There are two types of keylock: "Lockin-OFF type" which prevents the breaker from being CLOSED and "Lock-in-ON type" prevents it from being OENED. When the ACB is fitted with a key lock, the operator cannot operate the ACB unless using a matched key. Key interlock The key interlock is a system of interlocking between ACBs, each fitted with a key lock of lock-in OFF type. A key must be inserted to release the lock before the ACB can be closed. The ACB must be opened and locked in the OFF position before the key can be removed. By utilizing the lock-in OFF type key lock feature, and then a limited number of keys by default provides an effective and reliable interlock system. Using the same keys also allows interlocking between an ACB and other devices (such as a switchboard door). ACBs are supplied with a cylinder lock or with a provision for tyep FS-2 Castell lock (with angular movement 90 clockwise to trap key). The Castell lock is not supplied. Example: Interlock for prevention of parallel feeding of two power supplies when a bus-tie breaker is used. ACB 3 cannot be closed ACB 2 cannot be closed ACB 1 cannot be closed SOURCE1 ACB 1 SOURCE2 ACB 2 SOURCE1 ACB 1 SOURCE2 ACB 2 SOURCE1 ACB 1 SOURCE2 ACB 2 ACB 3 (Bus-tie breaker) ACB 3 (Bus-tie breaker) ACB 3 (Bus-tie breaker) Load1 Load2 Load1 Load2 Load1 Load2 /193

28 Optional accessories Mechanical interlock Mechanical interlocks for interlocking 2 or 3 ACBs in either horizontal (Draw-out type and fixed type) or vertical (Draw-out type only) arrangements are available. Interlocking is possible between any frame size of ACB. In conjunction with an electrical interlock, it will enhance safety and reliability of power distribution systems. 1. Horizontal type This table shows the standard pitch between left side ACB A and right side ACB B, or between left side ACB B and right side ACB C. Left ACB Right ACB DH08 to DH20 DH12H to DH20H 2. Vertical type Minimum pitch (550mm) is possible. Specify the reguired pitch when ordering. Maximum is 1200mm. Contact FUJI for the details of vertical type with 3 ACBs. itch of ACB (mm) (C line to C line) DH25 to DH30 DH16 to DH30 Rod DH40 3, 4 3, 4 3, 4 3, 4 DH08 to DH , 700, 600, 700, 500, 600, 700,, 1100 DH12H to DH20H 4 600, 700,, ,, , 700, 900,, 1100 DH25 to DH , 700,, ,, ,, ,, 1100 DH16 to 4 DH30 700,, 900,, 900,, 900,, 1100, 1200 DH40 3, 900,, ,, 1100, 900, 1100, 1200, , 1100, 1200, 1300, 1100, 1200, 1100, , 1 DH ,, 900,, 900, 700,, 900,, 1100, 1200 DH60 4, 1100, 1200, 1100, 1200, 1100, , 1300, 1 When ordering, select the required pitch for 1 and 2 from the above table, and specify the type and number of poles for ACB A, ACB B, and ACB C if exists. N DH50 DH60 Min. 550mm N Cable Min. R300mm A B C 1 2 Automatic closing spring release This device allows the charged closing springs to be automatically released when the ACB is drawn out from the ISOLATED position to the DRAW-OUT position. ANSI or NEMA-compliant ACBs require this option. Spring charge indicator This switch can be used to indicate that the closing springs have been fully charged. For the contact ratings of the switch, see the table 3-1 on page /181. N N Control circuit terminal cover A control circuit terminal cover protects the terminal blocks for auxiliary switches, position switches, and control circuits from being accidentally touched, thus enhancing safety. /194

29 Optional accessories Door flange A door flange can be used as a decoration panel that covers the cutout on the switchboard panel, and provides I20 protection. For I31 protection, please specify the door flange with a gasket. Note: Door flange cannot be specified with door interlock. T = MIN MAX anel Door Flange Standard With gasket I20 I31 Rubber shield (Use only I31 spec.) ± ±0.3 Front panel center line 270± ±0.3 10ø4.6* ± Floor level for ACB anel cutting *: Mount I20 door flange through 6 mounting holes and I31 door flange through 10 mounting holes. OFF padlock ermits the ACB to be padlocked in the OFF position. Max. three padlocks with 6mm dia. hasp can be fitted. adlocking is possible only when ON-OFF indicator shows OFF. When the ACB is padlocked in the OFF position, both manual and electrial closing become inoperative, but the charging of the closing spring by manual or motor is still possible. Note: OFF padlock facility cannot be fitted with key lock or key interlock. Interface barrier An interface barrier prevents a possible short-circuit due to foreign objects entering between the poles of the main circuit terminals or between the line and load ends, thus enhancing operational reliability of the ACB. This barrier cannot be applied to ACBs that are supplied with front connections or a reverse power trip function. Earthing device There is a growing demand in L.V. distribution for greater protection against electric shock particularly during periods when maintenance work is being carried out on the main busbars or cables. A safe and economical way to meet this requirement is to apply system earthing via the normal service breaker. Earthing devices on FUJI ACBs comprises; permanent parts which are factory fitted by FUJI and are mounted on the ACB chassis and body to enable the ACB to receive the portable parts. ortable parts are supplied in loose kit form and are fitted on to the ACB body by the customer s engineer. This converts the ACB from a normal service device to an earthing device. When the ACB is converted to the earthing device mode, the over current release and the other electrical tripping devices are automatically disabled to prevent the remote opening of the ACB. It is recommended that the ON-OFF operating buttons be padlocked to prevent manual opening of the ACB when used in the earthing mode. UVT function cannot be applied to the earthing device. /195

30 Optional accessories I cover An I cover provides an I55 grade of protection as required in IEC Even if the breaker body is on the ISOLATED position, I cover can still be fitted on the ACB. (ø6 adlocking) Hook Hinge anel 6-ø Domed cap nut Gasket Bushing Insert gasket and bushing when the I cover is fixed anel Floor level for ACB Hexagon socket head bolt 250 anel Cutout OCR checker, type ANU-1 The OCR checker allows easy checking of the long time-delay trip, short timedelay trip, instantaneous trip, ground fault trip functions and the pre-trip alarm function of the OCR in the field. Ratings and specifications ower supply V AC, 50/60Hz or V AC, 50/60Hz with type C plug 4 x AA alkaline cells ower consumption 7VA Dimensions 101 (W) x 195 (H) x 44 (D) mm Mass g Current transformer for neutral line (separately installed) When using a 3-pole ACB with the ground fault protection function to protect a 3-phase, 4-wire system against ground fault, install an appropriate current transformer (CT) to the neutral line of the system. FUJI can provide this neutral line CT as an option. For the 4-pole ACB, a measuring CT instead of the neutral line CT is already built into the ACB with ground fault protection function. Dimensions, mm CW80-40LS DH08, DH12, DH16 DH12H, DH16H, DH16 M5 50 EC160-40LS DH20, DH25, DH30, DH40, DH50, DH60 DH20H, DH20, DH25, DH30 60 M5 k L L K K ø160 4-M5 Tap for fixing secondary wiring 255 K k L 70 4-ø7 4-ø /196 Type Rated primary current CW80-40LS 200,,,, Rated secondary current is 5A. Type Rated primary current EC160-40LS,, 2500, 3200, 0, 5000, 6300 Rated secondary current is 5A.

31 Optional accessories (for draw-out type) Main circuit safety shutters The main circuit safety shutters automatically conceal the main circuit contacts on the draw-out cradle when the ACB is drawn out. The top and bottom shutters operate independently and can be separately padlocked in the closed position. Up to three padlocks (with 6mm dia. hasp) can be installed on each side using padlocking unit. (adlock not supplied) In the closed position, the shutters are locked to the extent that they cannot be easily unlocked by hand. They can be unlocked and held open if required for the purpose of inspection or maintenance. Control circuit safety shutter The control circuit safety shutter covers the control circuit contacts, ensuring safety. Test jumper The test jumper is a plug-in type, and allows ON-OFF tests on all the DH series ACBs with the breaker body drawn out from the draw-out cradle. The standard jumper cable is 5m long. Breaker fixing bolts The breaker fixing bolts hold the breaker body securely to the draw-out cradle in position. Use them if the ACB is subject to strong vibration. Mal-insertion prevention device Interchangeability exists within the DH series ACBs. Because of this feature, there is a possibility for an ACB of a different specification being placed into the draw-out cradle. Using the malinsertion prevention device eliminates such a possibility. This device is capable of distinguishing nine different breaker bodies. Lifter A special lifter is available to allow easy and safe transportation or installation of the ACB. A drop prevention mechanism is standard. ACB mounting position *190 max. ACB front panel Loader ACB 2300 Lifting plate Lifting plates are detachable tools that can be used to lift a breaker body out of a draw-out cradle. Grip Winch handle W Switchboard panel door *: If 190 mm is exceeded, contact FUJI. Type of Mass W Applicable Lifter (kg) (mm) ACBs AWR-1F to 3200A AWR-2F to 0A /197

DH series New OCR providing Higher Reliability

DH series New OCR providing Higher Reliability New OR providing Higher Reliability 8 EEH64b Variation Rated current [A] Rated Breaking capacity(ka sym.)/ Rated making current(ka peak) IE EN AS [Ics=Icu] Rated Voltage 69VA Rated Voltage 44VA 8A 5A 6A

More information

5. OVERCURRENT RELEASE (OCR)

5. OVERCURRENT RELEASE (OCR) 5. OVERCURRENT RELEASE (OCR) Options available for the type AR ACBs include a highly reliable, multi-functional overcurrent release (OCR) with a built-in 8- bit microprocessor. This OCR is supplied with

More information

5. OVERCURRENT RELEASE (OCR)

5. OVERCURRENT RELEASE (OCR) 5. OVERCURRENT RELEASE (OCR) Options available for the type AR ACBs include a highly reliable, multi-functional overcurrent release (OCR) with a built-in 8- bit microprocessor. This OCR is supplied with

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

Innovators in Protection Technology ACB. Double Breaker

Innovators in Protection Technology ACB. Double Breaker Innovators in Protection Technology ACB Double Breaker World Class Air Terasaki s TemPower2 A.C.B is the result of an intensive market research program which took into account the requirements of switchboard

More information

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits 7 Technical Data Dielectric strength Circuit Withstand voltage (at 50/60 Hz) Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB 1 Section Contents PAGES 1. Introduction 2-5 Salient features, internal & general appearance of Drawout ACB 2. Ratings & Specifications 6-9 Free air & enclosed thermal current ratings for AC & DC applications

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR208S AR212S AR216S AR220S AR325S AR332S AR440S AR440SB AR212H AR216H

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/14 2014 Class 0612 CONTENTS Description............................................. Page General Information..........................................

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) Types: AR208S AR212S AR216S AR220S AR325S AR332S AR440S AR440SB AR212H AR216H AR220H AR316H

More information

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection

More information

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs. SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6 The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 6 PROTECTIONS 1 FUNCTION OF ELECTRICAL PROTECTION SYSTEMS Problems:

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue Low voltage Masterpact NT and NW LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type Catalogue 2015 Functions and characteristics Circuit breakers and switch-disconnectors NT06

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) Types: KA208S KA212S KA216S KA220S KA325S KA332S KA440S KA212H KA216H KA220H KA316H KA320H

More information

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide GE Industrial Solutions Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide TABLE OF CONTENTS Description Page 1.0 General Information...... 1 1.1 Protection..... 1 2.0 UL Listed Devices...

More information

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Features: Low maintenance 10,000 mechanical operations (five times ANSI requirements) Simple magnetic actuator Vacuum interruption Definite

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic

More information

Air Circuit Breaker Instruction Manual

Air Circuit Breaker Instruction Manual Innovators in Protection Technology Air Circuit Breaker Instruction Manual AGR-21B/22B Protection Relays 06-M55EB INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-21B, 22B

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR650S, AR663S, AR663H Notice Be sure to read this manual before installing,

More information

Air Circuit Breaker Instruction Manual

Air Circuit Breaker Instruction Manual Innovators in Protection Technology Air Circuit Breaker Instruction Manual AGR-31B Overcurrent Protection Device 06-M55EC INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

Magnum IEC Low Voltage Air Circuit Breakers

Magnum IEC Low Voltage Air Circuit Breakers Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

High Breaking Capacity

High Breaking Capacity Air Circuit Breaker Small Light Weight High Breaking Capacity High Ability Digital APR Safety Convenience HiAN 2000 ~ 3200AF HiAN 6 ~ 1600AF CONTENTS HiAN Type 04 - Feature 06 - Rating 08 - Selection of

More information

Power Break II Switchboard

Power Break II Switchboard Power Break II Switchboard Now available with PowerBreak II Circuit Breakers through 4000A GE s Power Break II Switchboard is now available with the new Power Break II Insulated Case Circuit Breaker (800A

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

OPERATING CHARACTERISTICS

OPERATING CHARACTERISTICS TEMBREAK 2 MOULDED CASE CIRCUIT BREAKERS 16A TO 630A 1. Welcome to TemBreak 2 2. Ratings and Specifications 3. Operating Characteristics Thermal Magnetic Protection 23 Thermal Magnetic Time / Current Characteristics

More information

(Example) In case of DC24 to 48V, it is operating time for DC24V.

(Example) In case of DC24 to 48V, it is operating time for DC24V. 7 9 8 Closing coil (CC) The closing coil is a device to close the breaker by remote control. An interlock to prevent pumping is provided electrically. CC circuit diagram Rated voltage (Applicable voltage

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) Types: AR650S,AR663S,AR663H Notice Be sure to read this manual before installing, operating,

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

TemPower 2 Air Circuit Breaker

TemPower 2 Air Circuit Breaker TemPower 2 Air Circuit Breaker Safety, Performance, Protection, Reliability. POWER DISTRIBUTION AND PROTECTION NHP Electrical Engineering Products AUS NZ 1300 NHP NHP 0800 NHP NHP nhp.com.au nhpnz.com

More information

INSTRUCTION MANUAL FOR AR-E AIR CIRCUIT BREAKERS (Fixed type and Type AGR-12B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AR-E AIR CIRCUIT BREAKERS (Fixed type and Type AGR-12B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AR-E AIR CIRCUIT BREAKERS (Fixed type and Type AGR-12B Overcurrent Protective Device) Types: AR206E AR208E AR210E AR212E AR216E Notice Be sure to read this manual before installing,

More information

Air Circuit Breakers. U-Series. Instruction Manual. Type covered in this manual. Notice

Air Circuit Breakers. U-Series. Instruction Manual. Type covered in this manual. Notice U-Series Air Circuit Breakers Instruction Manual Type covered in this manual UAN Type : UAN06, UAN08, UAN10, UAN12, UAN16, UAN20, UAN25, UAN32, UAN40, UAN50 UAS Type : UAS06, UAS08, UAS10, UAS12, UAS16,

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

Critical Power Switchboards. Selection and Application Guide

Critical Power Switchboards. Selection and Application Guide Selection and Application Guide Siemens RCIII (rear connected) switchboards utilizing Siemens Type SB Encased Breakers are a perfect solution for your critical power distribution needs. Whether your installation

More information

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size

More information

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers GE Consumer & Industrial Electrical Distribution Power Break II Insulated Case Circuit Breakers Table of Contents Power Break II Circuit Breakers......................... 3 Basic Configuration.......................................

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

WORKSHOP SPECIFICATIONS

WORKSHOP SPECIFICATIONS WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

15-I73E CAT REF.

15-I73E CAT REF. & www.terasaki.co.jp 5-I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers

More information

Terasaki (Europe) Ltd

Terasaki (Europe) Ltd Terasaki (Europe) Ltd Terasaki Europe Ltd was established in 97 and is located near Glasgow, Scotland U.K. From head office at our 7,00 square metre facility, Terasaki Europe controls an International

More information

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Descriptive Bulletin R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Introduction The R-MAG TM is truly the next generation in medium voltage vacuum circuit breaker

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications Sectionalizing Rick Seeling Introduction Philosophy Pete Malamen Three Phase Reclosers High-Side Protection Specific Applications History Early 1970 s Small Substation Transformers

More information

3.2. Current Limiting Fuses. Contents

3.2. Current Limiting Fuses. Contents .2 Contents Description Current Limiting Applications................. Voltage Rating.......................... Interrupting Rating....................... Continuous Current Rating................ Fuse

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) Types: AR650S,AR663S,AR663H Notice Be sure to read this manual before installing, operating,

More information

Bolted contact switches. Pringle switches

Bolted contact switches. Pringle switches Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

14-I73E CAT REF.

14-I73E CAT REF. & www.terasaki.co.jp -I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

ACB l COMET AIR CIRCUIT BREAKER

ACB l COMET AIR CIRCUIT BREAKER ACB l COMET AIR CIRCUIT BREAKER MASCHINENBAU HALBERSTADT GROUP, building on its 60 years legacy in power generation, introduces COMET Air Circuit Breaker designed to meet the standards and the requirements

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

ACB l COMET AIR CIRCUIT BREAKER

ACB l COMET AIR CIRCUIT BREAKER ACB l COMET AIR CIRCUIT BREAKER MASCHINENBAU HALBERSTADT GmbH, building on its 60 year legacy in power generation, introduces COMET Air Circuit Breaker designed to meet the standards and the requirements

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear

More information

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual 11-M61E TABLE OF CONTENTS HANDLING & MAINTENANCE Storage 1 Transport 1 STANDARD ENVIRONMENT 1 INSTALLATION AND CONNECTION

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers VCP-T/T-VAC medium voltage vacuum circuit breakers Control protect with Eaton s compact medium voltage circuit breakers Eaton Corporation has dedicated years of research, design testing to create a comprehensive

More information

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Interruption Technology of Breakers for High-voltage Direct Current

Interruption Technology of Breakers for High-voltage Direct Current Interruption Technology of Breakers for High-voltage Direct MORIAI Hiroshi ABSTRT Applications for direct current () electric distribution have been spreading along with the increase of data centers and

More information