ACB l COMET AIR CIRCUIT BREAKER

Size: px
Start display at page:

Download "ACB l COMET AIR CIRCUIT BREAKER"

Transcription

1 ACB l COMET AIR CIRCUIT BREAKER

2 MASCHINENBAU HALBERSTADT GROUP, building on its 60 years legacy in power generation, introduces COMET Air Circuit Breaker designed to meet the standards and the requirements of its wide customer base. MBH ACB is the ideal solution to protect electrical equipment, isolate harmful discharges, and extend/improve the operation of industries worldwide.

3 INDEX COMET AIR CIRCUIT BREAKER 3 INTELLIGENT TRIP DEVICE 9 ACCESSORIES 21 CONTROL CIRCUIT & MECHANICAL INTERLOCK 27 STANDARD APPLICATIONS 33 DIMENSIONS 39 CATALOG NO. 43

4

5 COMET AIR CIRCUIT BREAKER

6 MBH ELECTRIC AIR CIRCUIT BREAKER LEGACY MBH Air Circuit Breaker is designed to meet and even surpass the standards and requirements for a wide range of applications: Buildings Offices Hotels Commercial Centers Hospitals Airports Data Centers Industries Chemical Plants Automotive Mining Factories Utilities and Infrastructure Electric Energy Generation and Distribution Oil and Gas Water 4

7 FEATURES ACB is a compact product that is optimized for package panel system: Enhanced reliability is ensured through modern structural design and excellent breaking capacity. Easy to maintain. Superior switching performance and excellent durability. Safety ACB sets the standard for safety, guaranteeing secure operations with its intelligent protection function, which incorporates a smart trip device that automatically kicks into action in the event of network problem. Furthermore, the RS 485 digitalized communication interface immediately displays on its LCD screen any tripping events such as instantaneous ground fault, low voltage trip, current unbalance and overheating. In the latter case, an overheat burn prevention is built-in in the form of a shunt coil. Highest Reliability The most important aspect of ACB is its unparalleled reliability, marking it as a superior product in the market. Enhanced reliability is ensured through a modern structural design that provides excellent sturdiness and breaking capacity. In addition, its high precision and reliable power supply source put forth a consistent performance that industries today depend on. Standardized Compact Size The ACB comes in a standardized compact size optimized for use in package panel system as well as enclosure installations. This versatility emphasizes the convenience of the ACB, setting it up as the easiest and most streamlined product available. Easy to Install and Maintain Featuring an impressively simplified design, the ACB is very easy to install and even easier to maintain. It offers reduced cost in both labor and time when carrying out both operations thanks to its convenient setup. Maintenance is further simplified by its digitalized communication interface, which provides high precision real time monitoring of current, load factor, bus bar temperature and line state, making sure any potential degradation is dealt with swiftly. 5

8 MBH ELECTRIC AIR CIRCUIT BREAKER Technical Description TYPE FRAME SIZE (AF) RATED CURRENT (In) (A) at 40Oc RATED VOLTAGE (Ue) (V) RATED INSULATION VOLTAGE (Ui) (V) RATED IMPULSE VOLTAGE (UiMP) (KV) FREQUENCY (HZ) NUMBER OF POLES (P) SET CURRENT (A) x In N-PHASE RATED CURRENT (%In) RATED BREAKING CURRENT (Icu) (KA) IEC RATED SERVICE BREAKING CAPACITY (Ics) (%Icu) RATED CLOSING CURRENT (Icm) (KA) IEC RATED SHIRT TIME CURRENT (Icw) KA/1s OPERATION TIME (ms) Breaking Time Closing Time 690V/600V/550V 500V/480V/460V 415V/380V/230V/220V 690V/600V/550V 500V/480V/460V 415V/380V/230V/220V Mechanical LIFE (No.) Electrical DIMENSION WxD (mm) Fixed Type H:310 Draw-Out Type H:432 3P 4P 3P 4P WEIGHT (Kg) Fixed Type Draw-Out Type 3P 4P 3P 4P 6

9 XLS06 XLS08 XLS10 XLS12 XLS16 XLS20 XLS25 XLS32 XLS40 F1 F2 F /60 50/60 3, 4 3, 4 0.5~ ~ x x x x x x x x x x x x

10

11 INTELLIGENT TRIP DEVICE

12 MBH ELECTRIC AIR CIRCUIT BREAKER USR-2 USR-6 TYPE USR-2 USR-6 CURRENT RELAY Long & Short Delay, Instantaneous, Ground Fault Long & Short Delay, Instantaneous, Ground Fault, Zone Selective Interlocking ADDITIONAL RELAY - Leakage (external CT) MEASUREMENT FUNCTION - Current (R/S/T/N) PRE TRIP ALARM - Overload Protective Relay DO output (alarm) PTA Ground unavailable when PTA is used COMMUNICATIONS - Modbus / RS-485 POWER Self Powered Turns on when current reaches 20% of rated value Self Powered - Turns on when current reaches 20% of rated value - External power used during the communication AC/DC 110~220V DC 24~48V RTC TIMER Availabe Availabe TRIP DISPLAY LED Long time delay trip - Long time delay - Long/Short Instantaneous time delay - Ground default FAULT RECORD - 10ea display default (phase/current/date/time) EVENT RECORD - 10ea knob setting OPERATION BUTTON - Reset S/I-LTD (menu/move/enter) 10

13 USR-2 OCR A state-of-the-art, high-speed micro controller is used. The current value can be checked; it displays the load factor and the line status. Easy to identify the faults by displaying trip event. (Long-time delay, short-time delay, instantaneous delay, low-voltage, unbalanced current and overheating). LED Displays Trip Data and Overload Status. LED flicker indicates that current exceeds 1.13xIn. LED light remains turned on following the tripping of the breaker. 11

14 MBH ELECTRIC AIR CIRCUIT BREAKER USR-6 OCR Overload Protection: Long Time Delay Protection. Short-Circuit Protection: Short Time Delay & Instanteneous Delay Protection. Ground Fault Protection: ZSI (Zone Selective Interlocking). Function enables easier interlocking for protection. Advanced MCU: Basic measured current. High-precision measurement. Fault Recording Function: 10 cases of fault type, fault phase, fault value and corresponding time log. 4 Digital Outputs (DO). Communication Function: Modbus / RS485. LED Trip Data and Overload Status Indicator. LCD Indicator measurement and data of each phase. RESET KEY Reset after OCR relay operation and after Battery Check. MENU Initial screen, move between setting menus. PTA (Pre Trip Alarm): Overload Protective Relay DO Output. LTD (Long Time Delay): Long Time Delay Relay Operation indicator. STD/INST (Short Time Delay/Instant): Indicators Short Time & Instantaneous Delay Operation. GFT/ELT: Indicators Ground Fault Operation. Alarm: Overload warning alarm (Turns on when load current reaches 0.9xIn. Flickers when current reaches 1.05xIn). LTD Ir: Long Time Delay Current Setting. Tr: Long Time Delay Time Setting. S/I Isd: Short Time Delay Current Setting. Tsd: Short Time Delay Time Setting. li: Instantaneous Time Current Setting. ENTER Move to Lower Menu or Input Setting. MOVE CURSOR Move to Menu or Reset; Left/Right Move of screen cursor or setting. 12

15 RELAY CHARACTERIStics OPERATING CHARACTERISTICS LONG TIME DELAY PROTECTION CURRENT RELAY Tripping between 1.05 & 1.20xl Time delay(s) SHORT TIME DELAY PROTECTION Current Settings (A) Time INSTANTANEOUS DELAY PROTECTION Current Settings (A) Tripping time GROUND FAULT PROTECTION Gorund pick-up(a) Time LEAKAGE PROTECTION (OPTION) Current Settings (A) Time delay(s) lu=lnx... lr=lnx... (1.5xlr) (6xlr) (7.2xlr) lsd=lrx... l2t off l2t on Tsd (max resettable time) Tsd(max break time) li=lrx... max. 50ms lg=lnx... l2t off l2t on Tg (max resettable time) Tg (max break time) lg Tg Long-Time, Short-Time & Instantaneous Delay Protection Ground Fault Protection 13

16 MBH ELECTRIC AIR CIRCUIT BREAKER RELAY CHARACTERIStics LONG TIME DELAY Overload protection. Time delay that is inversely proportional to the fault current. 1. Standard Current Setting Knob:lr 2. Delay Time Setting Knob: tr Operation Time at 6xIr. Setting Stages (9): Off sec. 3. Relay Pick-up Current Pick-up relay current: Relayed at current of (1.15)xIr or higher. 4. Calculation based on the highest load current among R/S/T/N SHORT TIME DELAY Isd tsd Over-current protection. Time delay and definite time that is inversely proportional to the fault current. 1. Standard Current Setting Knob: lsd Setting Stage: ( Off) lr. 2. Delay Time Setting Knob: Tsd Operation Time Standard: Operation Time at 10xIr. Inverse Time (lt On): /sec. Definite Time (lt On): /sec. 3. Calculation based on the highest load current among R/S/T/N. 4. ZSI (Zone Selective Interlocking) Instantaneous relay operation under protective interlocking when ZSI function is set. INSTANTANEOUS TIME DELAY Short circuit protection. When the fault current is above the preset value, it shall be dealt with within the shortest time possible to prevent accidents. 1. Standard Current Setting Knob: li Setting Range : ( Off) lu. 2. Calculation based on the highest phase current. 3. Overall breaking time shall be below 50ms. 14

17 GROUND FAULT DELAY Ground Fault Protection. When the ground current is above the preset value tripping of the breaker will occur. 1. Standard Current Setting Knob: Ig Setting Range : ( Off) ln. 2. Delay Time Setting Knob: tg Inverse Time (lt On): sec. Definite Time (lt On): sec. 3. Ground Current=Vector Sum of R-Phase+S-Phase+ T-Phase+N-Phase. 4. ZSI (Zone Selective Interlocking) Instantaneous relay operation under protective interlocking when ZSI function is set. 5. Ground Fault Protecting Function is included in the basic OCGR type (CT Type built-in). LEAKAGE PROTECTION OPTION Leakage Protection (Optional). When the leakage current is above the set value, it shall be broken after the time delay. 1. Standard Current Setting Knop: Ig Setting Range: Off(A). 2. Leakage (GFT) Trip Time: ms. Alarm Time: ms. 3. External CT used and exclusive for ZCT. 4. Necessity of using external CT Internal CT Type (Basic Type): Ground Fault Protection Protect 20%~100% of the ACB rated current. In case of a large-capacity ACB, the ground fault operating current will also increase. For example, in case of 4000A ACB, the minimum ground fault relay current is 4000A x 20% = 800A. Installation of an external CT is recommended to control the ground sensitivity current, and it is optional to protect the ground fault (leakage). 15

18 MBH ELECTRIC AIR CIRCUIT BREAKER ZONE SELECTIVE INTERLOCKING A Zone Selective Interlocking function is intended to protect the load equipments when a fault occurs. It minimizes the delay time and reduces damage to the air circuit breaker and load equipments. Following the operation of short-time delay or ground fault functions, in case of a fault, the concerned protective breaker sends ZSI signal after tripping to prevent upstream breakers from useless tripping. Hence the ZSI enforce continuity of service and reduce downtime of critical loads. In order to eliminate the fault condition, the ACB over-current relay performs an instantaneous trip to clear the fault. The upstream breaker, receiving the ZSI signal, shall refrain from tripping for a short preset time period under the Short-Time Delay or Ground Fault Time Delay functions. Upstream breakers that do not receive the ZSI signal shall trip instantaneously. For proper operation of ZSI, downstream breaker tripping time should be set lower than upstream breaker tripping time under Over-Current, Short Time Delay and Ground Fault Functions. In case of Fault-A: ACB1 independently performs the instantaneous trip. In case of Fault-B: ACB2 performs the instantaneous trip and ACB1 delays till the set time, then perform the instantaneous trip if the fault current is not cleared. 16

19 TRIP CHARACTERISTICS CURVE SHORT-TIME DELAY 17

20 MBH ELECTRIC AIR CIRCUIT BREAKER LONG-TIME DELAY 18

21 INSTANTANEOUS TIME DELAY, GROUND-FAULT t(s) PRE TRIP ALARM (PTA) t(s) *ln *ln 19

22

23 ACCESSORIES

24 MBH ELECTRIC AIR CIRCUIT BREAKER SHUNT TRIP (MX) RATED VOLTAGE (Vn) OPERATING VOLTAGE RANGE (V) POWER CONSUMPTION(VA/W) TRIP TIME(ms) DC(V) AC(V) INRUSH STEADY-STATE 24~ ~1.1Vn 48~ ~1.1Vn 100~ ~ ~1.1Vn ~ ~ ~1.1Vn - 380~ ~1.1Vn * THE AVAILABLE VOLTAGE RANGE IS THE MINIMUM RATING RANGE OF EACH RATED VOLTAGE (VN) WIRE SPECIFICATIONS WIRE TYPE DC 24~30(V) DC/AC 48(V) #16AWG(1.31) #18AWG(0.823) #16AWG(1.31) #18AWG(0.823) OPERATING VOLTAGE 80m 45m 330m 200m 45m 27m 210m 120m Power consumption 200VA, On a new line: Rated Voltage Vn DC 24 ~30V, DC/AC 48V. Recommended maximum wire length. CLOSING COIL (XF) RATED VOLTAGE (Vn) OPERATING VOLTAGE RANGE (V) POWER CONSUMPTION (VA/W) TRIP TIME (ms) DC(V) AC(V) PICK UP DROP OUT INRUSH STEADY-STATE 24~30-48~ ~ ~ ~0.85Vn 0.4~0.6Vn or under 200~ ~ ~480 * THE AVAILABLE VOLTAGE RANGE IS THE MINIMUM RATING RANGE OF EACH RATED VOLTAGE (VN) WIRE SPECIFICATION WIRE TYPE DC 24~30(V) DC/AC 48(V) #16AWG(1.31) #18AWG(0.823) #16AWG(1.31) #18AWG(0.823) OPERATING VOLTAGE 30.5m 18m 155m 95m 25m 15m 135m 80m Power consumption 200VA, On a new line: Rated Voltage Vn DC 24 ~30V, DC/AC 48V. Recommended maximum wire length. 22

25 GEAR (MCH) INPUT POWER DC 24~30V AC/DC 48~60V AC/DC 100~130V AC/DC 200~250V AC/DC 380~480V MOTOR LOAD CURRENT MOTOR ROTATION (RPM) INSULATED WITHSTAND VOLTAGE START LOAD CURRENT (max.) INSULATED WITHSTAND VOLTAGE 5A3A1A0.5A0.3A ~79.000rpm 2kV/min Less than 5 times of the load current 2kV/min OPERATING TEMPERATURE RANGE -20 / -60 DURABILITY CHARGE TIME CHARGE END CONTACT Operating Voltage Range: Voltage 85%~110% cycles (Load Continuous Operating Times: 2times/min) 5 sec or more 15A at 250V AC UNDER VOLTAGE TRIP DEVICE (MN) RATED VOLTAGE (Vn) OPERATING VOLTAGE RANGE (V) POWER CONSUMPTION (VA/W) DELAY TIME (ms) DC(V) AC(V) PICK UP DROP OUT INRUSH STEADY-STATE 48~ ~ ~ ~0.85Vn 0.4~0.6Vn , 2, 3 200~ ~250 FAULT TRIP INDICATION CONTACT (SDE) SDE-2 SDE-6 TYPE RESISTANCE LOAD INDUCTIVE LOAD RESISTANCE LOAD INDUCTIVE LOAD 250V 10A 6A 10A 10A CONTACT CAPACITY NO. OF AVAILABLE CONTACTS AC DC 125V 10A 6A 10A 10A 250V 0.3A 0.3A 3A 1.5A 125V 0.5A 0.6A 10A 6A 125V 0.5A 0.6A 10A 6A Standard OFF - Charge Type, 4NO4NC AL activates only following an OCR tripping action. The control signal is sent containing fault information. In case of a manual reset-reclosing operation is done after the AL (Alarm) switch is reset. In case of an automatic reset, the AL switch resets after operation of the remote reset device. 23

26 MBH ELECTRIC AIR CIRCUIT BREAKER Manual Reset Button Manual Reset Button (MRB), used to reset the CB allows re-closing following an OCR tripping operation. Operation Counter (CDM) A device used to indicate the number of operations the CB performed. ON / OFF Indication Contact (OF) 4 auxiliary contacts are used to monitor the CB ON/OFF status. Key Lock A lock device used to prevent unauthorized operation of certain CB, when using more than 2 CBs. Lifting Hook A safety device used to easily move CB. Used by attaching the hook to both handles of arc cover. 24

27 Drawout Device (Cradle Mounting Bracket) Mechanical mounting of CB body on the Cradle. Chassis Locking (Pad Lock / Position Lock) ACB is operated in position (CONNECTED, TEST, DISCONNECTED) when drawn-in/out. When the ACB body is drawn-in/out within the cradle, the handle will be locked at an idle status. LOCK is operated when the draw-in button is popped out. LOCK is cancelled by pressing the draw-in button in order to continue the draw-in/out operation. Relay Test Equipment A device to test whether OCR trip relay operates normally without power. Capable to withstand up to 17times the rated current. Input each current, value, size and phase of R/S/T/N. Different line frequencies can be tested. Testing long-time delay, short-time delay, instantaneous, ground fault protection functions. Attached to the door frame. Transparent cover. Mounted on the distribution panel to cover the breaker in order to prevent exposure to dust. Temperature Sensor Send alarm signal via RS-485 if temperature rises above the set operating temperature. Interphase Barrier Ensures phase-phase clearance. 25

28

29 CONTROL CIRCUIT & MECHANICAL INTERLOCK

30 MBH ELECTRIC AIR CIRCUIT BREAKER ELECTRICAL DIAGRAM Auxiliary P AC 220V / DC 110V Control Circuit wiring diagram P Voltage module V1 ZCT V2 V3 E1 485 Reset Common OFF R11 R T1 ON OFF ON Temperature module M1 C T1 TC1 T2 TC2 USR-6 Trip relay USR-6 Power UVT SHT L / S2 b 52Z L / S1 b L / S1 a 52M NC NC NC NC NC NO NO NO NO NO L / S3 a 52Z Temperature sensor 52C L / S4 b VN E U2 T2 M2 C N AC 220V / DC 110V GFT L/S/I Alarm Charged N Main circuit Digital trip relay UVT Trip coil Motor charge Closing coil Auxiliary contacts Communication Temperature Remote chutdown V1 VN Voltage module Aux. NO USR-6 power AC/DC R11 R22 USR-6 Reset Aux. NC C1 C2 Closing coil Tc1 Tc4 Temperature sensor module The cause of the accident USR-6 contact T1 T2 SHT trip coil E1 E2 ZCT connections terminals Pre Trip alarm U1 U2 UVT power supply RS-485 communication 28

31 MECHANICAL INTERLOCK Switches can be interlocked by using proper mechanical interlocks between the ACBs. Horizontal Type Used for a cable-type mechanical interlocking between 2 draw-out type circuit breakers. The maximum distance between interlocking circuit breakers is 2000mm. Vertical Type Vertical interlock is normally applied using a mechanical connecting nod to the draw-out type circuit breaker and it is used for the mechanical interlocking between 2 circuit breakers. CAUTION: User should refer to manual prior to installing mechanical interlock. SPACE SPACE 29

32 MBH ELECTRIC AIR CIRCUIT BREAKER Draw-out ACB Control Terminal Charge Handle Rating Plate Charge/Discharge Display ON / OFF Display Draw-in/out Handle, Insertion Point Draw-in/out Display Dram-in/out Handle Protection Relay OFF Button ON Button Internal Structure 1 Closing Coil 2 Trip Coil 3 Auxiliary Switch 4 Arc Extinguishing Chamber 5 Main Body of CB 19 6 Charging Handle Mechanism Shaft Closing Spring 9 Draw-out Mechanism Draw-out Cam Moving Contactor Fixed Contactor Load Side Conductor Draw-Out Conductor Circuit Breaker Connection Conductor 16 Power Supply Side Conductor 9 17 Safety Shutter 18 Insulation Mold Body Arc Runner 30

33 CONNECTED TEST DRAW-OUT It is a state where ACB body, main circuit and control circuit are all disconnected. ACB is completely disconnected from cradle. Check whether DISCONNECTED is displayed in the draw-out position display. CONNECTED TEST DRAW-OUT It displays the disconnection state of main circuit, ACB body and the connection state of control circuit. A switching test, Inspection and changing set value of the trip current of the protection relay are possible. Turn draw-out lever till the Test Point. CONNECTED TEST DRAW-OUT It displays the normal connection state of panel board circuit and ACB body. Check whether CONNECTED is displayed in the draw-out position display. 31

34

35 STANDARD APPLICATIONS

36 MBH ELECTRIC AIR CIRCUIT BREAKER OPERATING CONDITIONS Temperature Range Use within the range of max. +40 C and min. -5 C. The average 24-hour temperature should not exceed +35 C. Altitude 2000m or below. Environmental Condition Relative humidity should be lower than 85% at 20 C. Relative humidity should never exceed 90%. Avoid storage in the presence of oil gas, ammonia gas and corrosive gas. Storage Temperature Store it at max. +60 C and min. -20 C. The average 24-hour temperature should not exceed +35 C. Special Operational Environment If the ACB is installed in a high temperature and humid environment, electrical insulation and mechanical performance will be degraded. In this case, it is recommended to increase anti-corrosion resistance. Derating should be considered if ambient temperature exceeds 40 degrees. If the ACB is installed at altitudes above 2000m, heat emission, voltage, conduction capacity and breaking capacity will be reduced. Insulation level will decrease depending on air pressure. C CAUTION: Please consult our representatives for operations outside the specified ambient conditions. 34

37 STANDARD PROTECTION FOR ELECTRICAL NETWORKS Standard use of ACB MBH XLS ACBs are used in a wide range of industrial applications to protect equipment, conductors and devices in low voltage distribution networks. Short Circuit Breaking Capacity Nominal, overloads and short circuit currents must be determined in order to properly select and setup the ACB. The MBH XLS ACB must be properly sized to interrupt the maximum short circuit current as well as the lowest or weakest short circuit current at its point of installation. Protective Features The MBH XLS is equipped with a number of protection functions: Overload Protection Function: This feature allows the user the possibility of accurately adjusting the nominal current setting within the range of 0.5xIe. This feature also enables overload setting Ir. Time Short-Circuit Protection Function: The user must take into consideration the inrush currents, weak short circuit currents and fault current while setting of the Time Short Circuit Protection Function.The MBH XLS is designed to interrupt the faulted current within the required time frame while offering the needed selectivity across multiple levels and avoiding unwanted tripping on normal inrush currents. Instantaneous Short Circuit Protection: This feature enables instantaneous tripping action against high short circuit currents. The user usually sets the tripping current as a multiple of the primary overload adjustment. Ground Fault Protection Function: This feature grants the user the possibility of protection against ground fault currents thus protecting against damages to equipment and personnel. Generator Protection The protection device needs to be adjusted adequately in order to ensure quick and proper response against excessive generator overloading and short circuit conditions. Recommended timed short-circuit setting is 2.5xIr. 35

38 MBH ELECTRIC AIR CIRCUIT BREAKER Motor Protection The user should setup the ACB protective features such as to avoid tripping starting motor current. The following settings for timed short circuit device of a power circuit breaker are recommended: 12xIr with 50ms delay. 12xIe if instantaneous. The overload protection should incorporate a re-energization delay function in order to allow cooling of conductors and motors following an overload period. The user should consider including additional protective functions against motor operational anomalies such as phase loss detection and blocked rotor. Transformer Protection Transformers generally draw high inrush current upon energization. The peak inrush current, during the first half cycle, can reach values up to 15 to 25 times the normal transformer rated current. Protective devices should discriminate between inrush currents and short circuit currents and should not trip during energization. The following settings are recommended for transformer protection: 8xIr delayed 30ms. 15xIe~20xIe instantaneous. IEC TRIP CLASSES Trip Class 1.2xln 1.5xln 7.2xln 10A t<2hours t<2min 2 t<10 10 t<2hours t<4min 4 t<10 20 t<2hours t<8min 6 t<20 30 t<2hours t<12min 9 t<30 36

39 APPLICATION GUIDE Clearance Distances MBH ACB is tailored to break high short circuit current levels in a very short time frame. Breaking such current leads to emission of gas and some debris of conductive fragments. MIN. CLEARANCE FIXED ACB TO HOUSING Metal part Insulated part A B B MIN. CLEARANCE DRAWOUT ACB TO HOUSING Metal part Insulated part A 0 0 B B BUSBAR SIZING BREAKER TYPE CURRENT RATING RECOMMENDED COPPER BUSBAR XLS06 XLS08 630A 800A 1x50x10 or 1x100x5 XLS A 2x60x5 or 1x60x10 XLS A 2x40x10 or 2x80x5 XLS A 2x50x10 or 2x100x5 XLS A 3x50x10 or 3x100x5 XLS A 4x50x10 or 4x100x5 XLS32 XLS A 4000A 4x100x10 37

40

41 DIMENSIONS

42 MBH ELECTRIC AIR CIRCUIT BREAKER Fixed Type (2000A) Rated Current T(mm) W(mm) 1250A OR BELOW A A Draw-Out Type (2000A) Rated Current T(mm) W(mm) 1600A OR BELOW A

43 Fixed Type (2500~3200A) Rated Current T(mm) W(mm) 2500A A Draw-Out Type (2500~3200A) Rated Current T(mm) W(mm) 2500A A

44 MBH ELECTRIC AIR CIRCUIT BREAKER Fixed Type (4000A) Rated Current T(mm) W(mm) 4000A Draw-Out Type (4000A) Rated Current T(mm) W(mm) 4000A

45 catalog no. XLS F D 1 M AC2 mn Series XLS Air Circuit Breaker F1 F2 F3 Frames 630A ~ 1250A 1600A ~ 2000A 2500A ~ 4000A Rated Current A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A No. of Poles 3 3poles 4 4poles Installation Mode F Fixed Type D Draw-Out Type Over Current Trip Isolating Switch USR-2 USR-6 Normal LCD Operation M Motorized H Manual MN MX OF Auxiliary Voltage DC DC 110V AC AC 110V AC2 AC 220V Option Under Voltage Trip Shunt Trip USR External Contact Accessories Voltage *** *** To specify Accessories Voltage. 43

46 MBH ELECTRIC AIR CIRCUIT BREAKER Motorized ACB USR6 Catalog No. Order No. Product Description Motorized ACB - Fixed Type - USR-6 (LCD) Relay XLSF1063F2MDC ACB, Frame 1, 630A, 3P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF1063F2MAC ACB, Frame 1, 630A, 3P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF1063F2MAC ACB, Frame 1, 630A, 3P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF1064F2MDC ACB, Frame 1, 630A, 4P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF1064F2MAC ACB, Frame 1, 630A, 4P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF1064F2MAC ACB, Frame 1, 630A, 4P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF1083F2MDC ACB, Frame 1, 800A, 3P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF1083F2MAC ACB, Frame 1, 800A, 3P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF1083F2MAC ACB, Frame 1, 800A, 3P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF1084F2MDC ACB, Frame 1, 800A, 4P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF1084F2MAC ACB, Frame 1, 800A, 4P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF1084F2MAC ACB, Frame 1, 800A, 4P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF1103F2MDC ACB, Frame 1, 1000A, 3P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF1103F2MAC ACB, Frame 1, 1000A, 3P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF1103F2MAC ACB, Frame 1, 1000A, 3P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF1104F2MDC ACB, Frame 1, 1000A, 4P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF1104F2MAC ACB, Frame 1, 1000A, 4P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF1104F2MAC ACB, Frame 1, 1000A, 4P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF1123F2MDC ACB, Frame 1, 1250A, 3P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF1123F2MAC ACB, Frame 1, 1250A, 3P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF1123F2MAC ACB, Frame 1, 1250A, 3P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF1124F2MDC ACB, Frame 1, 1250A, 4P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF1124F2MAC ACB, Frame 1, 1250A, 4P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF1124F2MAC ACB, Frame 1, 1250A, 4P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF2163F2MDC ACB, Frame 2, 1600A, 3P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF2163F2MAC ACB, Frame 2, 1600A, 3P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF2163F2MAC ACB, Frame 2, 1600A, 3P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF2164F2MDC ACB, Frame 2, 1600A, 4P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF2164F2MAC ACB, Frame 2, 1600A, 4P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF2164F2MAC ACB, Frame 2, 1600A, 4P, Fixed, Motorized, AC 200V, USR-6 (LCD) 44

47 Catalog No. Order No. Product Description Motorized ACB - Fixed Type - USR-6 (LCD) Relay XLSF2203F2MDC ACB, Frame 2, 2000A, 3P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF2203F2MAC ACB, Frame 2, 2000A, 3P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF2203F2MAC ACB, Frame 2, 2000A, 3P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF2204F2MDC ACB, Frame 2, 2000A, 4P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF2204F2MAC ACB, Frame 2, 2000A, 4P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF2204F2MAC ACB, Frame 2, 2000A, 4P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF3253F2MDC ACB, Frame 3,2500A, 3P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF3253F2MAC ACB, Frame 3,2500A, 3P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF3253F2MAC ACB, Frame 3,2500A, 3P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF3254F2MDC ACB, Frame 3,2500A, 4P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF3254F2MAC ACB, Frame 3,2500A, 4P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF3254F2MAC ACB, Frame 3,2500A, 4P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF3323F2MDC ACB, Frame 3,3200A, 3P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF3323F2MAC ACB, Frame 3,3200A, 3P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF3323F2MAC ACB, Frame 3,3200A, 3P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF3324F2MDC ACB, Frame 3,3200A, 4P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF3324F2MAC ACB, Frame 3,3200A, 4P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF3324F2MAC ACB, Frame 3,3200A, 4P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF3403F2MDC ACB, Frame 3,4000A, 3P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF3403F2MAC ACB, Frame 3,4000A, 3P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF3403F2MAC ACB, Frame 3,4000A, 3P, Fixed, Motorized, AC 200V, USR-6 (LCD) XLSF3404F2MDC ACB, Frame 3,4000A, 4P, Fixed, Motorized, DC 110V, USR-6 (LCD) XLSF3404F2MAC ACB, Frame 3,4000A, 4P, Fixed, Motorized, AC 110V, USR-6 (LCD) XLSF3404F2MAC ACB, Frame 3,4000A, 4P, Fixed, Motorized, AC 200V, USR-6 (LCD) 45

48 MBH ELECTRIC AIR CIRCUIT BREAKER Motorized ACB USR6 Catalog No. Order No. Product Description Motorized ACB - Drawout Type - USR-6 Relay XLSF1063D2MDC ACB, Frame 1, 630A, 3P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF1063D2MAC ACB, Frame 1, 630A, 3P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF1063D2MAC ACB, Frame 1, 630A, 3P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF1064D2MDC ACB, Frame 1, 630A, 4P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF1064D2MAC ACB, Frame 1, 630A, 4P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF1064D2MAC ACB, Frame 1, 630A, 4P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF1083D2MDC ACB, Frame 1, 800A, 3P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF1083D2MAC ACB, Frame 1, 800A, 3P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF1083D2MAC ACB, Frame 1, 800A, 3P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF1084D2MDC ACB, Frame 1, 800A, 4P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF1084D2MAC ACB, Frame 1, 800A, 4P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF1084D2MAC ACB, Frame 1, 800A, 4P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF1103D2MDC ACB, Frame 1, 1000A, 3P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF1103D2MAC ACB, Frame 1, 1000A, 3P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF1103D2MAC ACB, Frame 1, 1000A, 3P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF1104D2MDC ACB, Frame 1, 1000A, 4P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF1104D2MAC ACB, Frame 1, 1000A, 4P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF1104D2MAC ACB, Frame 1, 1000A, 4P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF1123D2MDC ACB, Frame 1, 1250A, 3P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF1123D2MAC ACB, Frame 1, 1250A, 3P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF1123D2MAC ACB, Frame 1, 1250A, 3P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF1124D2MDC ACB, Frame 1, 1250A, 4P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF1124D2MAC ACB, Frame 1, 1250A, 4P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF1124D2MAC ACB, Frame 1, 1250A, 4P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF2163D2MDC ACB, Frame 2, 1600A, 3P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF2163D2MAC ACB, Frame 2, 1600A, 3P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF2163D2MAC ACB, Frame 2, 1600A, 3P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF2164D2MDC ACB, Frame 2, 1600A, 4P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF2164D2MAC ACB, Frame 2, 1600A, 4P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF2164D2MAC ACB, Frame 2, 1600A, 4P, Drawout, Motorized, AC 200V, USR-6 (LCD) 46

49 Catalog No. Order No. Product Description Motorized ACB - Drawout Type - USR-6 Relay XLSF2203D2MDC ACB, Frame 2, 2000A, 3P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF2203D2MAC ACB, Frame 2, 2000A, 3P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF2203D2MAC ACB, Frame 2, 2000A, 3P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF2204D2MDC ACB, Frame 2, 2000A, 4P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF2204D2MAC ACB, Frame 2, 2000A, 4P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF2204D2MAC ACB, Frame 2, 2000A, 4P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF3253D2MDC ACB, Frame 3,2500A, 3P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF3253D2MAC ACB, Frame 3,2500A, 3P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF3253D2MAC ACB, Frame 3,2500A, 3P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF3254D2MDC ACB, Frame 3,2500A, 4P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF3254D2MAC ACB, Frame 3,2500A, 4P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF3254D2MAC ACB, Frame 3,2500A, 4P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF3323D2MDC ACB, Frame 3,3200A, 3P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF3323D2MAC ACB, Frame 3,3200A, 3P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF3323D2MAC ACB, Frame 3,3200A, 3P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF3324D2MDC ACB, Frame 3,3200A, 4P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF3324D2MAC ACB, Frame 3,3200A, 4P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF3324D2MAC ACB, Frame 3,3200A, 4P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF3403D2MDC ACB, Frame 3,4000A, 3P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF3403D2MAC ACB, Frame 3,4000A, 3P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF3403D2MAC ACB, Frame 3,4000A, 3P, Drawout, Motorized, AC 200V, USR-6 (LCD) XLSF3404D2MDC ACB, Frame 3,4000A, 4P, Drawout, Motorized, DC 110V, USR-6 (LCD) XLSF3404D2MAC ACB, Frame 3,4000A, 4P, Drawout, Motorized, AC 110V, USR-6 (LCD) XLSF3404D2MAC ACB, Frame 3,4000A, 4P, Drawout, Motorized, AC 200V, USR-6 (LCD) 47

50

51

52 MBH Middle East & Africa Halat, Lebanon T middleeast@mbhelectric.de MBH Gulf Baniyas Complex Nasser Square Al Rigga Area Deira, Dubai, UAE T , F dubai@mbhelectric.de MBH Headquarters MASCHINENBAU HALBERSTADT GmbH Rudolf Diesel-Strasse 50 Halberstadt Germany T , F info@mbhelectric.de Maschinenbau Halberstadt Gmbh All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights.

ACB l COMET AIR CIRCUIT BREAKER

ACB l COMET AIR CIRCUIT BREAKER ACB l COMET AIR CIRCUIT BREAKER MASCHINENBAU HALBERSTADT GmbH, building on its 60 year legacy in power generation, introduces COMET Air Circuit Breaker designed to meet the standards and the requirements

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

CONTENTS. Dimensions A1-57

CONTENTS. Dimensions A1-57 A1 CONTENTS For industrial and residential Features A1-02 External & Internal Configuration A1-04 Basic Operation/Trip Method/Standards/Certification A1-06 Features A1-08 Ratings A1-10 OC(G)R(Over Current(Ground)Relay)

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

low voltage GLOBAL CATALOGUE RANGE ACB Air Circuit Breakers

low voltage GLOBAL CATALOGUE RANGE ACB Air Circuit Breakers CATALOGUE GLOBAL RANGE 3. ACB Air Circuit Breakers Inde 3. Air Circuit Breakers 3.1 ACB Product Overview Air Circuit Breakers 3.2-3.3 ACB Product Specifications 3.4 ACB Accessories Overview 3.5 ACB Accessory

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

5. OVERCURRENT RELEASE (OCR)

5. OVERCURRENT RELEASE (OCR) 5. OVERCURRENT RELEASE (OCR) Options available for the type AR ACBs include a highly reliable, multi-functional overcurrent release (OCR) with a built-in 8- bit microprocessor. This OCR is supplied with

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

Air Circuit Breakers. U-Series. Instruction Manual. Type covered in this manual. Notice

Air Circuit Breakers. U-Series. Instruction Manual. Type covered in this manual. Notice U-Series Air Circuit Breakers Instruction Manual Type covered in this manual UAN Type : UAN06, UAN08, UAN10, UAN12, UAN16, UAN20, UAN25, UAN32, UAN40, UAN50 UAS Type : UAS06, UAS08, UAS10, UAS12, UAS16,

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics:

More information

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics:

More information

(Example) In case of DC24 to 48V, it is operating time for DC24V.

(Example) In case of DC24 to 48V, it is operating time for DC24V. 7 9 8 Closing coil (CC) The closing coil is a device to close the breaker by remote control. An interlock to prevent pumping is provided electrically. CC circuit diagram Rated voltage (Applicable voltage

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue Low voltage Masterpact NT and NW LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type Catalogue 2015 Functions and characteristics Circuit breakers and switch-disconnectors NT06

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Masterpact NW DC Circuit Breakers

Masterpact NW DC Circuit Breakers Masterpact NW DC Circuit Breakers Catalog 0613CT0501 R06/15 2015 Class 0613 CONTENTS Description............................................. Page General Information..........................................

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

5. OVERCURRENT RELEASE (OCR)

5. OVERCURRENT RELEASE (OCR) 5. OVERCURRENT RELEASE (OCR) Options available for the type AR ACBs include a highly reliable, multi-functional overcurrent release (OCR) with a built-in 8- bit microprocessor. This OCR is supplied with

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Masterpact NW DC Circuit Breakers

Masterpact NW DC Circuit Breakers Masterpact NW DC Circuit Breakers Catalog 0613CT0501R1/07 2007 Class 0613DC CONTENTS Description..............................................Page Contents General Information Line 1.........................................

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact

More information

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size

More information

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/14 2014 Class 0612 CONTENTS Description............................................. Page General Information..........................................

More information

Air Circuit Breakers DH series General information

Air Circuit Breakers DH series General information General information Air circuit breakers Description The newly designed air circuit breakers have excellent features as follows: The height and depth dimensions are identical in all sizes up to 3200AF

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear

More information

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.

More information

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB 1 Section Contents PAGES 1. Introduction 2-5 Salient features, internal & general appearance of Drawout ACB 2. Ratings & Specifications 6-9 Free air & enclosed thermal current ratings for AC & DC applications

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

LSIS UL MCCB & Accessory

LSIS UL MCCB & Accessory LSIS UL MCCB & Accessory UL MCCB 100/150/250/400/600/800/1200AF UL MCCB Accessory 100/150/250/400/600/800/1200AF No. Specification 100AF 150AF 250AF 400AF 600AF 800AF 1200AF 1 2 3 4 5 6 7 8 9 10 11 12

More information

Contents. We build a better future! MCC HCB

Contents. We build a better future! MCC HCB H8PU Low Voltage We build a better future! HYUNDAI s low voltage motor control center H8PU series with a withdrawable unit are of multi-tier, factory assembled and for rated voltage of up to 660V AC. Contents

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) Types: KA208S KA212S KA216S KA220S KA325S KA332S KA440S KA212H KA216H KA220H KA316H KA320H

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR650S, AR663S, AR663H Notice Be sure to read this manual before installing,

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications LOW VOLTAGE SACE Emax 2/ML Low-voltage air circuit breakers for naval applications 2 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS SACE Emax 2/ML Robustness and reliability up

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

Magnum IEC Low Voltage Air Circuit Breakers

Magnum IEC Low Voltage Air Circuit Breakers Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven

More information

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits 7 Technical Data Dielectric strength Circuit Withstand voltage (at 50/60 Hz) Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR208S AR212S AR216S AR220S AR325S AR332S AR440S AR440SB AR212H AR216H

More information

PIX-H Metal-clad switchgear up to 17.5kV

PIX-H Metal-clad switchgear up to 17.5kV AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

ACB/ATS Air Circuit Breaker / Automatic Transfer Switch

ACB/ATS Air Circuit Breaker / Automatic Transfer Switch ACB/ATS Air Circuit Breaker / Automatic Transfer Switch ACB/ATS Air Circuit Breaker / Automatic Transfer Switch CREATING VALUE 02_03 No matter where you are in the world or in which industrial field, Daeryuk

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

Air Circuit Breaker Instruction Manual

Air Circuit Breaker Instruction Manual Innovators in Protection Technology Air Circuit Breaker Instruction Manual AGR-31B Overcurrent Protection Device 06-M55EC INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times. The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection

More information

Submittal Data Information

Submittal Data Information Effective: NOVEMBER 3, 2014 JOB CONTRCTOR ITEM NO. Submittal Data Information TS - Taco dvanced Starter ENGINEER REP. 301-2690 Supersedes: NEW TS - Taco dvanced Starter 1Ø, 120-230V, 1/10-30HP 3Ø, 200-600V,

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M MS50T3L M2N200T3L na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) Types: AR208S AR212S AR216S AR220S AR325S AR332S AR440S AR440SB AR212H AR216H AR220H AR316H

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual 11-M61E TABLE OF CONTENTS HANDLING & MAINTENANCE Storage 1 Transport 1 STANDARD ENVIRONMENT 1 INSTALLATION AND CONNECTION

More information

SafeGear TM Motor Control Center Arc resistant metal-clad construction

SafeGear TM Motor Control Center Arc resistant metal-clad construction SafeGear TM Motor Control Center Arc resistant metal-clad construction Contents Description 2 SafeGear TM MCC applications 3 Electrical features 3 Standards 3 Standard service conditions 4 HCV vacuum contactor

More information

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide GE Industrial Solutions Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide TABLE OF CONTENTS Description Page 1.0 General Information...... 1 1.1 Protection..... 1 2.0 UL Listed Devices...

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V. Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit

More information

New range of reclosing systems

New range of reclosing systems Protection and Control RECmax New range of reclosing systems Earth leakage and circuit breaker protection with automatic earth leakage reclosing system. Manage its installation remotely Energy efficiency

More information

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge.

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge. Vacuum Contactor HYUNDAI Vacuum Contactors are designed and manufactured for frequent switchings, especially taking into account safety and quality assurance. They are suitable for switching and controlling

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

Medium voltage vacuum circuit breaker. E-VAC series

Medium voltage vacuum circuit breaker. E-VAC series Medium voltage vacuum circuit breaker E-VAC series Product description E-VAC vacuum circuit breaker Contents Description Product description... Technical data... Dimensions... Wiring diagram... E-VAC series

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers .1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size

More information

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443 CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) Types: AR650S,AR663S,AR663H Notice Be sure to read this manual before installing, operating,

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) Types: AR650S,AR663S,AR663H Notice Be sure to read this manual before installing, operating,

More information