1 Power protection solutions DMX A.C.Bs UP TO 4000 A

2 In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and coupling of supplies - Divide the main circuits. These functions whose definitions are simple but which are of major importance with respect to the need for reliability and continuity of operation. Because it must include the control of all these components, Legrand s answer today for power distribution boards up to 4000 A is logically based on the three essential elements which make up the head of a low voltage installation: - XL 3 enclosures with their recognized qualities of robustness and adaptability - Busbar systems and supports for 5 and 10 mm thick bars tested up to ka - The DMX air circuit breakers from 800 to 4000 A in fixed, draw-out and interlocking versions.

3 Contents Technical part DMX air circuit breakers 2 CHOICE of XL 3 enclosure 22 BUSBARS up to 4000 A 28 MOUNTING DMX devices 36 Offer part DMX 40 1

4 DMX air circuit breakers DMX circuit breakers and isolating switches provide control and protection at the head of low voltage distribution installations up to 4000 A. Find the complete offer on page 40 2

5 DMX AIR CIRCUIT BREAKERS The technology of the air circuit breaker has improved considerably: in fact breaking does not really take place in the open air anymore, but in sophisticated arcing chambers, and the equipment has become a great deal smaller. At the same time, their specific characteristics (electrical and mechanical strength, breaking capacity, maintainability, optional accessories, etc) have also been developed. The Legrand DMX units have evolved in line with these general developments. They are used to protect the most powerful installations. Their ease of installation and clarity of layout have been particularly carefully studied. All devices in the DMX range are mounted behind the same front panel and have same depth and height. A 4000 A system within your reach DMX Fixed or draw-out Circuit breaker with MP17 integrated electronic protection unit. OPTION MP20 electronic protection unit with advanced functions. INTEGRATION Clear, easy mounting All DMX have the same front panel, and are the same depth and height. CONNECTION AND IDENTIFICATION OF AUXILIARIES On front panel terminal block 32 connection points available Identification on front panel Accessories attached via front panel for extremely easy installation. CONTROL AND SIGNALLING AUXILIARIES Shunt release Undervoltage release Motor operators Closing release Signalling contacts Locking options 3

6 DMX air circuit breakers (continued) THE DMX RANGE DMX circuit breakers and switches are available in just two frame sizes: - DMX and DMX-I 0 (800, 1, 1600, 2000 and 0 A ratings) - DMX and DMX-I 4000 (3200 and 4000 A ratings). The designation DMX corresponds to a standard breaking capacity of 50 ka (1) while DMX-H offers a breaking capacity of 65 ka (1),and DMX-L a breaking capacity of 100 ka (1). With the DMX-L, the size of the devices is identical to that of the DMX 4000 for all ratings from 800 to 4000 A. (1) (at 415 V±) DMX 0 fixed version DMX 0 draw-out version DMX 4000 draw-out version One catalogue number = one complete product All breakers are delivered as standard with: - MP17 electronic trip unit - 8 Auxiliary contacts 5NO+3NC - Rear connection - Auxiliary terminal block - Padlocking shroud for ON and OFF buttons - Panel door seal For draw-out, the following features are delivered as standard as well: All DMX, both circuit breakers and isolating switches, are available in fixed and draw-out version. In comparison with the fixed version, the draw-out version has additional locking facilities, optimum safety when work is being carried out on them and on the installation (padlocking and physical separation of the installation) and is easily interchangeable (no disconnection to be carried out). - Lockable safety shutters - Racking handle - Adjustable rear terminals 4

7 TECHNICAL PART Retractable handles are used to draw out the device Safety shutters provide protection against the risk of contact with live parts, as standard on every DMX External Memory Unit The design of the DMX contributes considerably to their strength and maintainability. Removing the front panel gives direct access to all the control and signalling auxiliaries: trips, coils, contacts, motorisation, counter, etc. If a device is changed, the external memory unit (EMU) retains the settings and all the data recorded during the operation of the breaker which was previously installed (faults, operations, currents, etc). This function makes safe maintenance and reduces downtime to a minimum. The settings are thus not associated with the device anymore, but with the circuit which is being protected. 5

8 DMX air circuit breakers (continued) ELECTRONIC TRIP UNITS In addition to the integration capabilities of these circuit breakers, their easy mounting and connection, strength and the maximum continuity of operation they provide, they also have modern electronic protection units which enable very precise setting of protection conditions while maintaining total discrimination with downstream breakers. MP17 electronic protection unit DMX circuit breakers are equipped with the MP17 electronic protection unit as standard. The settings are adjusted using rotary selector switches: - Long time delay protection against overloads: Ir from 0.4 to 1 x In (7 steps) - Short time delay protection against short circuits: Im from 2 to 12 x Ir (7 steps) - Short time delay protection operation time: Tm from 0 to 1 s (7 steps) The protection unit is adjusted using rotary selector switches and therefore independently of the power supply of the device. The MP17 protection unit also has instantaneous protection against very high intensity short-circuits. MP17 protection unit on draw-out DMX 0 t (s) Ir Ir setting Reset button Im Im and Tm settings Tripping curve Tm LED indicating correct operation I (A) Test connector and portable external power supply 6

9 10000 t(s) 1000 Tripping curve for electronic protection unit MP17 Adjustement of Ir, Im, Tm on front face Ir I t (A s) 10 9 Thermal stress limitation curve for electronic protection unit MP17 TECHNICAL PART Im Tm I/Ir If ka Ik (A) Long delay protection against overloads Ir = 0,4-0,5-0,6-0,7-0,8-0,9-1 x In (7 steps) Neutral protection at 50% of the value of phases Short delay protection against short-circuits Im = x Ir (7 steps) Tm = instantaneous -0,1-0,2-0,4-0,6-0,8-1,0 s (7 steps) Instantaneous protection If = 50 ka for DMX 65 ka for DMX-H 80 ka for DMX-L 7

10 DMX air circuit breakers (continued) ELECTRONIC TRIP UNITS (CONTINUED) MP20 electronic protection unit On request, DMX circuit breakers can be fitted with MP20 electronic protection units which have advanced functions. The settings are adjusted via a touch sensitive keypad with the setting point displayed on an illuminated curve. Numbers of operations, maintenance indicator, fault history, load shedding parameters (early warning, load control) and current values can be displayed. Modbus or Profibus communication and control functions are also available. Every MP20 is equipped with EMU. Possible settings: - Long time delay protection against overloads: Ir from 0.4 to 1.0 x In (60 steps) - Long time delay protection operation time: tr from 0.25 to 35 s (16 steps) - Delayed protection against short circuits: Imr from 1.5 to 12 x Ir (8 steps) - Delayed protection operation time: tmr from 1 to 10 s (tr function) - Short delay protection against short circuits: Im from 1.5 to 12 x Ir (8 steps) - Short delay protection operation time: tm from 0 to 1 s (10 steps) - Instantaneous protection against very high short circuits t (s) Liquid crystal display Alarm indicator Ir Correct operation indicator Tripping curve with display tr Imr tmr Im tm I (A) Reset button (manual or auto) Tripping curve for earth fault with display Touch-sensitive keypad Test connector and portable external power supply MP20 control & protection unit on DMX 4000 circuit breaker 8

11 Tripping curve for electronic protection unit MP20 Adjustement of Ir, Imr, Tmr, Im, Tm t(s) Ir I t (A s) Thermal stress limitation curve for electronic protection unit MP20 TECHNICAL PAR(T Tr Imr Tmr Im Tm ka I/Ir If Long delay protection against overloads Ir = 0,4 to 1,0 In (by steps of 0,01) Tr =,025 to 35 s at 7,2 x Ir (16 steps) Ik (A) Delayed protection against short-circuits Imr = 1, x Ir Tmr = fixed according to Tr Short delay protection against short-circuits Im = 1, x Ir Tm = instantaneous -0,1-0,2-0,3-0,4-0,5-0,6-0,7-0,8-0,9-1,0 s Instantaneous protection If = 50 ka for DMX 65 ka for DMX-H 80 ka for DMX-L Protection against earth fault : On request, the MP17 & MP20 protection units can be equipped with protection against earth faults. The level of the earth fault current is adjustable from 0 to 1.0 x In in 6 steps on MP17 protection units and 10 steps on MP20. The time delay on tripping is adjustable from 0 to 1s. MP20 units also have a I 2 t = constant function for eliminating the unwanted section of the protection curve. This function can be deactivated at any time. 9

12 DMX air circuit breakers (continued) Front panel of draw-out DMX circuit breakers External memory unit (EMU) Electronic protection unit MP20 Protective cover with security of access to settings Identification of the type DMX: grey DMX-H: yellow DMX-L: red Space for a lock (device open) Device position indication Plugged-in: red Test: yellow Drawn-out: greeen Padlocking in drawn-out position ( 2 padlocks) Isolator terminal blocks for auxiliary circuits Windows for displaying auxiliary equipment Spring loading lever (stored energy control) Circuit breaker: black lever Switch: grey lever Padlockable close control button Padlockable open control button Indicator showing the position of the main contacts Indicator showing the load status of the springs Housing for the extraction handle (This housing can be fitted with a lock in drawn-out position) Independent padlocking of the isolating shutters Lockable aperture for insertion of the extraction handle Safety device for insertion of the extraction handle 10

13 CONTROL ACCESSORIES Shunt trips Shunt trips are devices used for the remote instantaneous opening of the device. They are generally controlled with an N/O type contact. These devices are available in AC and DC versions, with various supply voltages. They are simply clipped on to the front panel of the device. No tool required. An auxiliary contact is connected in series with the coil, cutting off its power supply when the main poles are open. Nominal voltage Un : 48 V=, 110/130 V±/=, 220/ V±/=, 380/440 V± Tolerance on nominal voltage: 0.7 to 1.1 x Un Maximum opening time: 50 ms Maximum power consumption: VA (for ±) and W (for =) Undervoltage release Undervoltage releases are devices which are generally controlled by an N/C type contact. They trigger instantaneous opening of the circuit breaker if their supply voltage drops below a certain threshold and in particular if the control contact opens. These releases are equipped with a device for limiting their consumption after the circuit has been closed. They are simply clipped on to the front panel of the device. No tool required. Nominal voltage Un: 24/30 V=, 48 V=, 110/130 V=, 220/ V±, 380/440 V± Tolerance on nominal voltage: 0.85 to 1.1 x Un Trip voltage: 35% Feedback voltage: 60% Opening time: 50 ms Maximum power consumption: VA reduced to 20 VA after 400 ms Time delay undervoltage releases These releases are equipped with an electronic device which delays their operation for approximately 3 seconds. They are designed to be used in unstable supplies, where the supply voltage of the release may be subject to variations or microbreaks, to avoid unwanted opening of the circuit breaker. They are also equipped with a power saving device for limiting their consumption. They are simply clipped on to the front panel of the device. Nominal voltage Un: 48 V=, 110/130 V=, 220/ V±, 380/440 V± Tolerance on nominal voltage: 0.85 to 1.1 Un Trip voltage: 35% Feedback voltage: 60% Tripping time: 3 s Maximum power consumption: VA reduced to 20 VA after 400 ms. Closing coils These coils are used for remotely controlling the closing of the circuit breaker (the circuit breaker being dependent on the prior loading of the springs). They are controlled by an N/O type contact. They are simply clipped on to the front panel of the device. No tool required. Nominal voltage Un: 24/30 V=, 48 V=, 110/130 V±/=, 230/ V± Tolerance on nominal voltage: 0.85 to 1.1 Un Opening time: 50 ms Power consumption: VA (for ±) and W (for =). Number of control auxiliaries for DMX Shunt trip 1 Undervoltage release (standard or time delayed) 1 Closing coils 1 11

14 DMX air circuit breakers (continued) Motor operators Motor operators, which are available in different voltages, are used for remotely reloading the springs of the circuit breaker mechanism immediately after the device closes. The device can thus be re-closed almost immediately after an opening operation. Combined with a release (current shunt trip or undervoltage release) and a closing coil, they can thus be used for remotely controlling the circuit breaker. If the supply voltage of the controls fails, it is still possible to reload the springs manually. Motor-driven controls have limit switch contacts which cut off the power supply of their motor after the springs have been reloaded. An auxiliary signalling contact Cat. No can be added to feed back the load status of the springs. They are easy to mount, with only three screws. Nominal voltage Un: 24/30 V=, 48 V=, 110/130 V=, 110/130 V±, 230/ V± Tolerance on nominal voltage: 0.85 to 1.1 x Un Spring reloading time: 3 s Maximum power consumption: VA (for ±) and W (for =) Mounting accessories Shunt trip Closing coil Undervoltage release (standard or time delayed) Motor-driven control 12

15 SIGNALLING ACCESSORIES Signalling contacts All DMX devices are equipped as standard with 8 auxiliary contacts (5 N/O + 3 N/C). An electrical fault signal contact (1 N/O) Cat. No can be added to indicate a fault trip. This contact remains closed until the device is reset. Permissible current: 10 A for V±, 5 A for 125 V=, 0.25 A for V=, Utilization category: AC23 DC3 (2 contacts in series). Position indicating contacts An additional block of 12 changeover contacts (6 N/O+ 6 N/C) Cat. No can be fitted on the draw-out versions to indicate the position of the device in its base (inserted/test/drawn-out). The drawn-out position is indicated only when the minimum clearances of the main circuit and the auxiliary circuits are reached. The contact block is supplied in a 6 N/0 + 6 N/C configuration, but it can be reconfigured by the user according to requirements. Connection and identification of accessories Electrical auxiliaries are connected on the front panel on terminal blocks provided for this purpose : 32 connection points available. Accessories are identified on the front panel. As the cover has window, it is easy to ascertain which coils are fitted on the device. In addition, an identification label each device indicates its composition on delivery.. SAFETY AND PADLOCKING ACCESSORIES The DMX circuit breakers and switches draw-out types are delivery as standard with safety padlocking shutters preventing access to live terminals. They have a number of other safety devices. Using padlocks: - ON/OFF buttons - Safety shutters - Drawn-out position and insertion of handle By key-operated lock: - Main contacts open - Isolated position Using an obstacle: - Protection unit settings - Insertion of the handle - Rating locating pin By cable interlocking, for supply inversion (see page 14) 13

16 DMX air circuit breakers (continued) SUPPLY INVERTORS All DMX and DMX-I devices (fixed and draw-out version) can be fitted with an interlocking mechanism which guarantees mechanical safety in the event of supply inversion. Interlocking is achieved using interlocking units mounted on the side of the devices and a cable system. This system allows devices of different sizes and types (3P, 4P, fixed, draw-out) to be interlocked. The cable system provides the flexibility to install DMX devices in a vertical configuration in the same enclosure or in a horizontal configuration in different columns. This mechanical interlocking system can be supplemented by motorised operators and an automation control unit (Cat. No ), making the inverter fully automatic. The interlocking mechanism with cables is easy to add to all DMX versions and is not dependent on their position in the assembly (2 m long cable as standard, other lengths on demand) Automation control unit Cat. No to make the inverter fully automatic FOR MORE INFORMATION DMX air circuit breakers with supply inversion. The two circuit breakers are connected to a common transfer busbar Triple inverters: Please consult us 14

17 WIRING DIAGRAM LP7 user's designated circuits D1 D4 D7 D10 D13 D16 B7 B9 B1 B11 B13 B15 C1 C3 C5 C7 C9 C11 C13 C15 +Ve +Ve +Ve B AL M ML ST CC UVI or UVT -Ve D3 D6 D9 D12 D15 D18 B8 B10 B2 B12 B14 B16 C2 C4 C6 C8 C10 C12 C14 C16 D2 D5 D8 D11 D14 D17 -Ve -Ve LP1 LP2 LP3 LP4 LP5 LP6 user's designated circuits B1 TO B16 C1 TO C16 D1 TO D6 D7 TO D12 D13 TO D18 Terminal References Automatic disconnect L.T. blocks Automatic disconnect L.T. blocks Carriage switch blocks for disconnect position (1) Carriage switch blocks for test position (1) Carriage switch blocks for connect position (1) (1) Changeover contacts can be reconfigured by user LP1 LP2 LP3 LP4 LP5 LP6 Optional features LP7 CC UV UVTD AL ML M ST Key Disconnected indication Test indication connected indication ACB tripped indication ACB OFF indication ACB On indication Closing springs charged indication Closing coil Undervoltage release Time delayed undervoltage release MP trip alarm (N/O) Charging motor limit switch Closing spring charging motor Shunt trip 15

18 DMX air circuit breakers (continued) CONNECTIONS Correct sizing and connection are essential for the reliability of installations and in particular for high power equipment. DMX devices have generously sized connection plates. On the draw-out versions the connection plates take multi-directional rear terminals. Minimum recommended dimension of connection plates and bars per pole Rear terminals Ie (A) Flexible bars (mm) Rigid bars (mm) P x 50 x 10 or 2 x 50 x 5 2 x 50 x x 50 x 10 or 2 x 50 x 5 2 x 50 x 5 DMX 0 fixed 17 10, P 1 2 x 50 x 5 1 x 50 x x 50 x x 50 x x 50 x 5 2 x 50 x x 50 x 10 2 x 60 x 10 10, x 50 x 10 3 x 60 x P x 50 x 10 or 2 x 50 x 5 2 x 50 x x 50 x 5 2 x 63 x 5 DMX 0 draw-out Ø ,5 22,5 1 1 x 50 x x 50 x 5 2 x 63 x x 50 x 10 1 or 2 x 60 x x 63 x 5 or 2 x 60 x x 60 x 10 or 2 x 80 x x 60 x 10 or 3 x 80 x 10 Fixed version x 75 x 5 or 1 x 80 x 5 DMX-L 0 DMX/DMX-L 4000 fixed and draw-out Draw-out version P P Ø , , ,5 42, x 100 x x 75 x 5 or 2 x 80 x x 100 x x 100 x 5 or 2 x 80 x x 100 x x 100 x x 100 x 10 16

19 The rear terminals can be positioned vertically or horizontally on the draw-out versions Tightening torque of rear terminals: 45 to 50 Nm. Connection of two 80 x 10 bars on each rear terminal of draw-out DMX 0 Connections : a few recommendations! Connections provide the electrical connection of equipment and are also responsible for a considerable proportion of their heat dissipation. Connections must never be under-sized. Plates or terminals must be used over a maximum area. Heat dissipation is encouraged by arranging the bars vertically. If an uneven number of bars is connected, place the higher number of bars on the upper part of the terminal. Avoid bars running side by side: this causes poor heat dissipation and vibrations. Place spacers between the bars to maintain a distance between them which is at least equivalent to their thickness. Connection of four 100 x 10 bars on each rear terminal of draw-out DMX

20 DMX air circuit breakers (continued) ELECTRICAL CARACTERISTICS According to IEC 947-2/947-3 Type of circuit breaker / type of trip free switches DMX DMX DMX DMX-I DMX-I Size No of poles ELECTRICAL CHARACTERISTICS (IEC 947-3) Rated service voltage Ue V± V= Rated impulse withstand voltage Uimp (kv) Rated impulse withstand voltage Uimp (kv) Category of use B B B B B B B B Rated frequency (Hz) Rated current of the release In (A) Neutral protection (% I of phase) Level of performance H L H L H L H L H L H L H L H L Breaking capacity Icu (ka) for DMX Icm (ka) for DMX-I 230 V± V± V± V± V± Service breaking capacity Ics (% Icu) Short time withstand current Icw (ka) t = 1s Suitability for isolation Display circuit breaker state Display contacts state Display springs charged/discharged POSSIBLE ACCESSORIES Electronic release with microprocessor MP /17 Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series MP /20 OptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Protection against overload Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Protection against short-circuit Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Protection against earth fault OptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Auxiliary contacts (5 NO + 3 NC) Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Alarm contacts 1 NO OptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Opening releases OptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Closing coil OptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Motorised spring charging unit OptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Fixed version Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Draw-out version Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Mechanical interlocks (2 to 3 units) OptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptionalOptional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional 18 19

21 DMX air circuit breakers (continued) DIMENSIONS DMX 2 500, DMX-I Fixed version Base for draw-out version P : P : P : P : P : P : , P : P : P : P : P : P : 429 Draw-out version 3 P : P : Ø ,

22 DMX DMX-H 2 500/ DMX-L 2 500/ DMX-I Fixed version P : P : 540 Base for draw-out version TECHNICAL PART P : P : P : P : , P : P : P : P : 549 Draw-out version 3 P : P : Ø

23 Choice of XL 3 enclosure The XL enclosures are available in 3 widths and 3 depths, so its easy for you to create the configuration you want 22

24 Before building a distribution assembly, consideration must be given to the choice of enclosure. This must be the subject of particular care, in view of the power ratings involved. The restrictions connected with possible short circuits and heat dissipation aspects are of the utmost importance. On the one hand, busbars must be sized and held in place in accordance with established rules, on the other hand, the enclosures must be chosen so that their internal temperature remains acceptable. Ambient temperature The ambient temperature in the enclosure must be limited as far as possible to a value which does not exceed 40 C. Above this it becomes necessary to derate the permissible current in the protection devices and the bars. It is very important to take the actual load currents and the cooling conditions of the enclosure into consideration, in particular those connected with its protection index (IP rating). In XL 3, the DMX devices and the associated busbars are arranged according to an identical principle for all power ratings, that is, the possibility of mounting three busbars and two devices per enclosure. The correct size for the current, and thus the power to be dissipated, is obtained by adapting the depth of the assembly: mm min. up to 0 A mm min. up to 4000 A 4000 A main distribution board in XL equipped with 2 DMX in supply inverter configuration 23

25 Choice of XL 3 enclosure (continued) ASSEMBLY CONFIGURATIONS The simplicity of the principle for installing DMXs and busbars in XL enclosures makes it easy to convert the head of installation electrical diagram to the layout diagram. The examples of usual configurations, given on the following pages, can be used to assist with designing assemblies. The installation height of DMX units is always 600 mm whatever the type and size of the device. When 2 DMX devices are installed in the same cell, this leaves a useful 600 mm for running the busbars. Mounting principles Spaces for installing a connection, transfer, or main busbar Sleeve for any incoming cables Compulsory sleeve for 4-pole draw-out DMX 4000 and DMX-L 0/4000 or for vertical busbar 24

26 BASIC CONFIGURATIONS Stand-by power supply (without load shedding) Stand-by power supply (without load shedding) G G D1 D2 D1 D3 D2 Non priority circuits Priority circuits non priority circuits D1 D1 D3 priority circuits D2 D2 The two DMX devices (D1 and D2) are connected to a central common busbar. Since they are not simultaneously on-load, they can be in the same enclosure. The two DMX devices (D1 and D2) are not on-load simultaneously and can therefore be installed in the same enclosure. D3 can be on-load at the same time as D1, and must be installed in another enclosure. 25

27 Choice of XL 3 enclosure (continued) BASIC CONFIGURATIONS (continued) Dual power supply (total power) Dual power supply (reduced power with priority loads) D1 D2 D1 D2 D3 D4 Non priority circuits group 1 Non priority circuits group 2 D1 Priority circuits D2 D1 D2 non priority circuits group 1 D1 D3 priority circuits D2 D4 The two DMX devices (D1 and D2) draw current on a common busbar. They can only be installed in the same enclosure if the sum of their currents does not exceed the permissible value for the recommended size. non priority circuits group 2 26

28 Stand-by power Dual supply power (without supply load with shedding) stand-by and coupling on common supplied circuits G G D1 D3 D2 D4 D5 D6 Group 1 circuits ( I1 ) Group 2 circuits ( I2 ) Group 3 circuits ( I1 + I2 ) Sizing for D1 or D2 up to 4000 A Group 2 circuits D1 D2 D6 Group 3 circuits D3 D4 D5 Group 1 circuits If the sum of the actual load currents of devices D1 and D2 does not exceed the permissible value for the recommended size, the size of the assembly may be optimised. D1 D2 D3 D4 D5 D6 Group 1 circuits Group 3 circuits Group 2 circuits 27

29 Busbars up to 4000 A Numerous compositions of standard busbars enable all possible configurations up to 4000 A, in other enclosure and wiring sleeves 28

30 Isolating supports Cat. Nos and take one to four 5 mm thick flat bars up to 120 x 5 or one to three 10 mm thick flat bars up to 125 x 10. They can be used to create numerous busbar configurations: - Transfer busbars - Main busbars at the top or the bottom - Horizontal main busbars at the back of the enclosure - Side-mounted vertical busbars in enclosure and wiring sleeve (internal and external) Support Cat. Nos /25: 4 possibilities for assembly Top or bottom horizontal main busbar (1) Transfer busbar (2) Fixed support Cat. No The 4000 A busbar can be supplemented by branch busbars or by the XL-Part system. Side-mounted vertical busbars Main busbar at the back (1) Fitting a top or bottom main busbar in a 725 mm depth enclosure requires the creation of a partial chassis (2) Fitting a transfer busbar in a 725 mm depth enclosure requires the creation of a partial chassis and the use of 2 internal or external wiring sleeves. 29

31 Busbars up to 4000 A (continued) DETERMINING THE APPROPRIATE CROSS-SECTION Supports Cat. No to 4 bars, 5 mm thick, per pole 1 to 3 bars, 10 mm thick, per pole The required cross-section of the bars is determined according to the operating current, the protection index (IP rating) of the enclosure and after checking the short circuit thermal stress. The currents are named according to the definitions in standard IEC applied to the usual operating conditions for a temperature rise!t of the bars which does not exceed 65 C. Current according to standard IEC Ie: rated operating current to be taken into consideration in enclosures with natural ventilation or in panels which have an IP rating < 30 (ambient internal temperature < 25 C). Ithe: thermal current in enclosure corresponding to the most severe installation conditions. Weatherproof enclosures do not allow natural renewal of the air. The IP rating is > 30 (ambient internal temperature < 50 C). The permissible current in n bars is less than n times the permissible current in one bar. Use n = 1.6 to 1.8 for a group of 2 bars, n = 2.2 to 2.4 for 3 bars and n = 2.7 to 2.9 for 4 bars. The wider the bars, the more coefficient n is affected, the more difficult they are to cool and the higher the mutual inductance effects. The permissible current density is not therefore constant: It is approximately 3 A/mm 2 for small bars and drops to 1 A/mm 2 for groups of large bars. 30

32 Rigid flat copper bars - edgewise mounting le(a) IP30 Ithe(A) IP >30 Number Dimensions (mm) I 2 t (A 2 s) x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 5 (1) 1.17 x x 5 (1) 4.67 x x 5 (1) 1.05 x x 5 (1) 1.87 x (1) needs stainless steel threaded assembly rod, diameter 8, to be supplied separately and cut to length le(a) IP30 Ithe(A) IP >30 Number Dimensions (mm) I 2 t (A 2 s) x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Positioning of the groups of bars Bars mounted edgewise on vertical busbars or horizontal on supports Cat. No in horizontal position 31

33 Busbars up to 4000 A (continued) DETERMINING THE DISTANCES BETWEEN SUPPORTS The distance between supports is determined according to the electrodynamic stress generated by the short circuit. The forces exerted between the bars during a short circuit are proportional to the peak value of the short circuit current. RMS value of the prospective short circuit current (Ik) This is the prospective maximum value of the current which would circulate during a short circuit if there were no protection device. Value of the peak current (Ipk) Since air circuit breakers have restricted limitation characteristics, the value of the prospective peak current is determined using the prospective short circuit current and applying of the cœfficient of asymmetry. Prospective short-circuit current This is the RMS value of the short circuit current which would circulate if there were no protection device. Ik 1 : between phase and neutral Ik 2 : between 2 phases Ik 3 : between 3 phases. These values must not be confused with Ipk. The electrodynamic forces are proportional to the square of the peak current. It is this value which must be taken into consideration when determining the distances between the supports. Limiting protection device According to the rating of the prospective short-circuit, the limitation curves of protection devices (DX and DPX) give the rating of the limited peak. The non-limited peak lcs curve corresponds to an absence of protection. The table below gives instantly the limited peak value (lpk) for the maximum prospective shortcircuit value equal to the breaking capacity (lcu) of the device. For lower prospective short-circuit values, reading the curves will provide an optimised value. Isc Peak (ka) Isc peak limited Non limited Isc peak Prospective Isc Limitation curve RMS Isc (ka) Device Rating (A) Max. peak Isc (ka) DPX DPX DPX DPX DPX to DPX ER 100 to 22 DPX 40 to 27 DPX-H 40 to 34 DPX 630 to DPX-H 630 to DPX to DPX-H to

34 Value of asymmetrical first peak Cœfficient of asymmetry Peak Isc RMS value of Isc Practical determination of the distances between the supports according to the peak current (Ipk) The following tables can be used to determine the maximum distances D (in mm) between 2 supports, and thus create sets of busbars, based on the required Ipk value. The shorter the distance between the supports, the higher the permissible Ik. Time The relationship between the peak value and the RMS value of the prospective short-circuit current is defined by the cœfficient of asymmetry n: D Prospective RMS Isc (ka) n " < I " < I " < I " < I 2.2 The distance D after the last support must always be less than 30% of the distance D D D' 33

35 Busbars up to 4000 A (continued) Maximum distance D (in mm) for multipole supports Cat. Nos /25/54 with 5 mm thick copper bars Bars Peak Isc (Ipk in ka) bar per pole 2 bars per pole 75 x 5 Bars 75 x 5 50 x 5 63 x x x 5 50 x 5 63 x x x 5 80 x 5 80 x Peak Isc (Ipk in ka) Bars Peak Isc (Ipk in ka) bars per pole 4 bars per pole 50 x 5 63 x 5 75 x 5 Bars 75 x x x 5 50 x 5 63 x 5 80 x 5 80 x x x 5 Peak Isc (Ipk in ka)

36 Maximum distance D (in mm) for multipole supports Cat. Nos with 10 mm thick copper bars Bars Peak Isc (Ipk in ka) x x bar per pole x Bars Peak Isc (Ipk in ka) x x bars per pole x Bars 3 bars per pole 80 x x 10 Peak Isc (Ipk in ka) x

37 Mounting DMX devices 36

38 DMX circuit breakers and switches are mounted on horizontal plates. These plates are available for fixed version and draw-out version DMXs and for 24 modules (width 600 mm) and 36 modules (width 850 mm) XL enclosures. They consist of a horizontal plate and a strengthening crosspiece. Fixed DMX device DMX devices up to 0 A are mounted in 24 modules enclosures with a usable width of 600 mm. 600 Draw-out DMX device Mounting fitting plate for DMX in XL enclosure 600 DMX plates have pre-drilled holes to enable the insertion of interlocking cables for supply inversion mountings 37

39 Mounting DMX device (continued) PLATE SELECTION CHART Version Fixed devices Draw-out devices XL enclosure type 24 modules I = 600 mm 36 modules I = 850 mm 24 modules I = 600 mm 36 modules I = 850 mm DMX 0 DMX 4000 DMX-L 0 DMX-L P P P P Fixed or draw-out DMX devices are placed on the plate and fixed using screws and nuts. Given the weight of the devices, the use of lifting equipment is strongly recommended. FINISH The metal faceplates for DMX devices are 600 mm in height and equipped with hinges and a lock to facilitate maintenance operations. Installing a draw-out DMX in its base Faceplate for draw-out DMX devices in 24 modules XL enclosures FACEPLATE SELECTION CHART Version Fixed devices Draw-out devices XL enclosure type 24 modules I = 600 mm 36 modules I = 850 mm 24 modules I = 600 mm 36 modules I = 850 mm DMX 0 DMX 4000 DMX-L 0 DMX-L P P P P

40 CHOOSE YOUR DMX DMX, DMX-H AND DMX-L AIR CIRCUIT BREAKERS Nominal rating (A) Breaking capacity Fixed version Draw-out version (ka) 3P 4P 3P 4P DMX-I TRIP FREE SWITCHES Nominal rating (A) 3P Fixed version 4P Draw-out version 3P 4P CONVERSION OF A FIXED DEVICE INTO A DRAW-OUT DEVICE Base + Cluster contacts Nominal rating DMX-L (A) DMX, DMX-H and DMX-I DMX-L DMX, DMX-H and DMX-I 3P 4P 3P 4P 3P 4P 3P 4P

41 DMX for example: xxxxxxx 800 xxxxxxxx to A air circuit breakers Dimensions (p. 20) Technical characteristics (p. 18) Air circuit breakers equipped with a trip unit (MP 17 (1) electronic protection unit), rear terminals and auxiliary contacts (5 NO + 3 NC) The DMX air circuit breakers in the draw-out version are delivered with a base equipped with adjustable rear terminals and independently lockable upstream/downstream isolation shutters Pack Cat.Nos Fixed version DMX-H Breaking capacity Icu 50 ka (415 V±) 3P 4P In A A A A A A Pack Cat.Nos Draw-out version DMX Breaking capacity Icu 50 ka (415 V±) 3P 4P In A A A A A A DMX-H Breaking capacity Icu 65 ka (415 V±) 3P 4P In A A A A A A DMX-H Breaking capacity Icu 65 ka (415 V±) 3P 4P In A A A A A A DMX-L Breaking capacity Icu 100 ka (415 V±) 3P 4P In A A A A A A DMX-L Breaking capacity Icu 100 ka (415 V±) 3P 4P In A A A A A A Accessories (p. 44) Accessories (p. 44) (1) base protection 40

42 DMX and A air circuit breakers Dimensions (p. 20) Technical characteristics (p. 18) Air circuit breakers equipped with a trip unit (MP 17 (1) electronic protection unit), rear terminals and auxiliary contacts (5 NO + 3 NC) The DMX air circuit breakers in the draw-out version are delivered with a base equipped with adjustable rear terminals and independently lockable upstream/downstream isolation shutters Pack Cat.Nos Fixed version DMX Breaking capacity Icu 50 ka (415 V±) 3P 4P In A A Pack Cat.Nos Draw-out version DMX Breaking capacity Icu 50 ka (415 V±) 3P 4P In A A DMX-H Breaking capacity Icu 65 ka (415 V±) 3P 4P In A A DMX-H Breaking capacity Icu 65 ka (415 V±) 3P 4P In A A DMX-L Breaking capacity Icu 100 ka (415 V±) 3P 4P In A A DMX-L Breaking capacity Icu 100 ka (415 V±) 3P 4P In A A FOR MORE INFORMATION Ask for our technical manual Distribution and Power Auxiliaries see p. 43 (1) base protection 41

43 DMX TM electronic protection units DMX-I trip free switches from 1 to 4000 A MP 17 supplied on DMX as standard MP 18 supplied on request only MP 20 supplied on request only Curves (p. 43) Dimensions (p. 20) DMX and DMX circuit breakers take protection units that enable very precise adjustments of the protection conditions, while maintaining total discrimination with downstream devices Pack Cat.Nos Electronic protection unit MP 17 As standard DMX and DMX are equipped with electronic protection unit MP 17 with Ir, Im, Tm, Ii adjustments on the front t(s) Im Ir Tm Test equipment For checking the operation of the protection unit and tripping and opening conditions of the DMX poles Test unit External power supply For powering the protection unit when the circuit breaker is open or not powered Fixed unsecured external power supply Ii Electronic protection units on request On request, DMX s can be equipped with an electronic protection unit including an LCD adjustable by keyboard and an external memory unit on drawout versions MP 18 Consult Enables Ir, Im, Tr adjustments on the front us Functions : - current display - fault adjustment and log MP 20 Consult Enables Ir, Imr, Tmr, Im, Tm adjustments on the front us Functions : - current display - fault adjustment and log Optional functions can be added: - load check and load-shedding - trip warning - centralised communication and check function - auxiliary power supply I(A) Non-automatic air-circuit breakers with rear terminals and auxiliary contacts (5 NO + 3 NC) Pack Cat.Nos DMX-I Fixed version 3P 4P In A A A A Draw-out version 3P 4P In A A A A The DMX trip free switches in the draw-out version are delivered with a base equipped with adjustable rear terminals and independently lockable upstream/downstream isolation shutters DMX-I Fixed version 3P 4P In A A A A Draw-out version The DMX trip free switches in the draw-out version are delivered with a base equipped with adjustable rear terminals and independently lockable upstream/downstream isolation shutters 3P 4P In A A Choice of faceplates (see Legrand General Catalogue) For electronic protection units MP 18, MP 20 mounted on DMX, please consult us 42

44 DMX, DMX-H, DMX-L, DMX-I control and signalling auxiliaries Technical characteristics (p. 11, 13) Pack Cat.Nos Control and signalling auxiliaries Shunt trip When energised the circuit breaker will be tripped V= V= /130 VA or / VA or /440 VA or = Undervoltage releases When the coil is de-energised, the circuit breaker will be tripped V= V= /130 V= / VA /440 VA Delayed undervoltage releases Improves immunity to nuisance tripping V= /130 V= / VA or /440 VA or = Motor operators To motorise a DMX, it is necessary to attach, to the motor operators, a release coil (undervoltage or trip on energising) and a closing coil The motor operator is delivered with a spring charge contact /30 V= V= /130 VA /130 V= / VA Pack Cat.Nos Control and signalling auxiliaries (continued) Closing coils Enables remote closing of the circuit breaker if the closing spring is charged /30 V= V= /130 VA and / VA and = Signalling contacts NO fault signal contact NO + 6 NC position contact (in/test/out) for draw-out version Locking Key locking in "open" position Mounting of the lock on the ACBs Ronis lock (lock and key included) Profalux lock (lock and key not included) Key locking in the draw-out position Mounting of the lock on the base Ronis lock (lock and key included) Profalux lock (lock and key not included) Door locking Prevents opening of the door with the circuit breaker closed Left-hand side mounting (hinges on the right) Right-hand side mounting (hinges on the left) FOR MORE INFORMATION See the our technical manual Distribution and Power 43

45 for DMX, example: DMX-H, xxxxxxx DMX-L, DMX-I xxxxxxxx accessories for example: xxxxxxx xxxxxxxx DMX 0, mounted on base Cat. No Pack Cat.Nos Accessories Rating mis-insertion device Prevents the insertion of a draw-out circuit breaker in an incompatible base Base/circuit breaker insertion lock Rating mis-insertion device Counts total number of operation cycles of the device Operations counter Equipment for supply invertors The mechanical interlocking of devices which are placed above one another or installed side by side requires an interlocking unit for each device and a cable set Interlocking units For installation on the side of circuit breakers DMX, DMX-H, DMX-L and DMX-I 3P 4P Fixed version For DMX 2 500, DMX-H and DMX-I For DMX 2 500, DMX-H and DMX-I Draw-out version For DMX 2 500, DMX-H and DMX-I For DMX 4 000, DMX-H 4 000, DMX-L 2 500/4 000 and DMX-I Cables for interlocking assemblies Set of cables for 2 devices (l = 2m) Pack Cat.Nos Conversion of a fixed device into a draw-out device Converting a fixed device requires a base, a set of cluster contacts and a mounting tool Bases for draw-out device Accept ACBs equipped with cluster 3P 4P contacts For DMX 2 500, DMX-H and DMX-I For DMX 4 000, DMX-H 4 000, DMX-L 2 500/4 000 and DMX-I In A For DMX 4 000, DMX-H 4 000, DMX-L 2 500/4 000 and DMX-I In = A Sets of cluster contacts For use on the rear terminals of the fixed devices using the mounting tool For DMX 2 500, DMX-H and DMX-I In A For DMX 2 500, DMX-H and DMX-I In = A and A For DMX 4 000, DMX-H 4 000, DMX-L 2 500/4 000 and DMX-I In A For DMX 4 000, DMX-H 4 000, DMX-L 2 500/4 000 and DMX-I In = A Cluster mounting tool Necessary for mounting the clusters on the rear terminals of the device Cluster mounting tool Automation control unit For setting the conditions for supply inversion, generator on/off, status acquisition for DMX and DPX circuitbreakers, open/closed Power supply: 230 V or V Connection by plug-in terminals Standard unit Communicating unit, enabling data transmission (RS 485 port) NEW 44

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

MCBs and RCDs LR TM 6000

MCBs and RCDs LR TM 6000 MCBs and RCDs LR TM 6000 thermal magnetic MCBs from 6 A to 63 A B and C curves residual current devices from 25 A to 63 A AC and A types ± ± ± ± MCBs Single pole 230/400 V± Single pole neutral 230 V± (1)

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES O S O O CABINETS AND ENCLOSURES XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES II With its extensive ranges, the Legrand offer meets your quality standards and

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

NEW TX³ RANGE PROTECTION YOU CAN RELY ON TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

WORKSHOP SPECIFICATIONS

WORKSHOP SPECIFICATIONS WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

New DX 3 High rating & breaking capacity

New DX 3 High rating & breaking capacity New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX³ RCBO 6000 A Phase + Neutral, neutral right side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

Busbars and distribution

Busbars and distribution Busbars and distribution 12 Power guide 2009 / book 12 INTRO Protection and control of operating circuits are the basic functions of a distribution panel. But upstream there is another function, possibly

More information

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

XL Distribution enclosures WORKSHOP SPECIFICATIONS

XL Distribution enclosures WORKSHOP SPECIFICATIONS 800 Distribution enclosures WORKSHOP SPECIFICATIONS With its extensive ranges, the Legrand offer meets your quality standards and provides real freedom and simplicity of installation together with acknowledged

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 / 10 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

DX³ RCBO 6000A Phase + Neutral, neutral on left

DX³ RCBO 6000A Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES APRIL 2015 Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 380 415 440 460 480 550 600 NEMA-ABI 240 (HIC)

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES price list THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES APRIL 2014 P. 07 P. 08 DMX3 ACB from 630 A to 2500 A Fixed version Draw-out version P. 13 cat.a Ui690V Uimp6kV 50 60Hz

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Btdin-RS RCBO 2p Phase + Neutral, neutral on right Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES MAY 2018 Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 125 380 415 10 440 460 10 480 550 7.5 600 5 NEMA-ABI

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES AUGUST 2017 P. 07 P. 08 DMX3 ACB from 630 A to 2500 A Fixed version Draw-out version P. 12 cat.a Ui690V Uimp6kV 50 60Hz

More information

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Overcurrent releases - description, specifications, characteristics specifications specifications description... BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

DX³ RCBO 6000A Phase + Neutral, neutral on right

DX³ RCBO 6000A Phase + Neutral, neutral on right 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Magnum IEC Low Voltage Air Circuit Breakers

Magnum IEC Low Voltage Air Circuit Breakers Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

Cascading & Discrimination

Cascading & Discrimination Cascading & Discrimination Typical LV System Level 1 ACBs - 6300A General LV Switchboard Level 2 ACB - 3200A MCCB 3200A Level 3 MCCB 1250A Fuses 630A Switchboard, Panelboard or MCC Level 4 MCBs - 100A

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

C60H-DC C curve. Catalogue numbers

C60H-DC C curve. Catalogue numbers distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions

More information

Cat N 3. OVERALL DIMENSIONS

Cat N 3. OVERALL DIMENSIONS Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

dx 3 protection that meets your requirements GloBal SpecialiSt IN electrical AND DIgITAl BUIlDINg INFrASTrUCTUreS catalogue pages inside

dx 3 protection that meets your requirements GloBal SpecialiSt IN electrical AND DIgITAl BUIlDINg INFrASTrUCTUreS catalogue pages inside dx 3 protection that meets your requirements catalogue pages inside GloBal SpecialiSt IN electrical AND DIgITAl BUIlDINg INFrASTrUCTUreS the new dx 3 legrand offer offers you leading-edge technical features

More information

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information