ACB l COMET AIR CIRCUIT BREAKER
|
|
- Steven Malone
- 6 years ago
- Views:
Transcription
1 ACB l COMET AIR CIRCUIT BREAKER
2 MASCHINENBAU HALBERSTADT GmbH, building on its 60 year legacy in power generation, introduces COMET Air Circuit Breaker designed to meet the standards and the requirements of its wide customer base. MBH ACB is the ideal solution to protect electrical equipment, isolate harmful discharges, and extend/improve the operation of industries worldwide.
3 INDEX COMET AIR CIRCUIT BREAKER 3 INTELLIGENT TRIP DEVICE 9 ACCESSORIES 21 CONTROL CIRCUIT & MECHANICAL INTERLOCK 27 STANDARD APPLICATIONS 33 DIMENSIONS 39 CATALOG NO. 43
4
5 COMET AIR CIRCUIT BREAKER
6 MBH ELECTRIC AIR CIRCUIT BREAKER LEGACY MBH Air Circuit Breaker is designed to meet and even surpass the standards and requirements for a wide range of applications: Buildings Offices Hotels Commercial Centers Hospitals Airports Data Centers Industries Chemical Plants Automotive Mining Factories Utilities and Infrastructure Electric Energy Generation and Distribution Oil and Gas Water 4
7 features ACB is a compact product that is optimized for package panel system: Enhanced reliability is ensured through modern structural design and excellent breaking capacity. Easy to maintain. Superior switching performance and excellent durability. Safety ACB sets the standard for safety, guaranteeing secure operations with its intelligent protection function, which incorporates a smart trip device that automatically kicks into action in the event of network problem. Furthermore, the RS 485 digitalized communication interface immediately displays on its LCD screen any tripping events such as instantaneous ground fault, low voltage trip, current unbalance and overheating. In the latter case, an overheat burn prevention is built-in in the form of a shunt coil. Highest Reliability The most important aspect of ACB is its unparalleled reliability, marking it as a superior product in the market. Enhanced reliability is ensured through a modern structural design that provides excellent sturdiness and breaking capacity. In addition, its high precision and reliable power supply source put forth a consistent performance that industries today depend on. Standardized Compact Size The ACB comes in a standardized compact size optimized for use in package panel system as well as enclosure installations. This versatility emphasizes the convenience of the ACB, setting it up as the easiest and most streamlined product available. Easy to Install and Maintain Featuring an impressively simplified design, the ACB is very easy to install and even easier to maintain. It offers reduced cost in both labor and time when carrying out both operations thanks to its convenient setup. Maintenance is further simplified by its digitalized communication interface, which provides high precision real time monitoring of current, load factor, bus bar temperature and line state, making sure any potential degradation is dealt with swiftly. 5
8 MBH ELECTRIC AIR CIRCUIT BREAKER Technical Description TYPE FRAME SIZE (AF) RATED CURRENT (In) (A) at 40Oc RATED VOLTAGE (Ue) (V) RATED INSULATION VOLTAGE (Ui) (V) RATED IMPULSE VOLTAGE (UiMP) (KV) FREQUENCY (HZ) NUMBER OF POLES (P) SET CURRENT (A) x In N-PHASE RATED CURRENT (%In) RATED BREAKING CURRENT (Icu) (KA) IEC RATED SERVICE BREAKING CAPACITY (Ics) (%Icu) RATED CLOSING CURRENT (Icm) (KA) IEC RATED SHIRT TIME CURRENT (Icw) KA/1s OPERATION TIME (ms) Breaking Time Closing Time 690V/600V/550V 500V/480V/460V 415V/380V/230V/220V 690V/600V/550V 500V/480V/460V 415V/380V/230V/220V Mechanical LIFE (No.) Electrical DIMENSION WxD (mm) Fixed Type H:310 Draw-Out Type H:432 3P 4P 3P 4P WEIGHT (Kg) Fixed Type Draw-Out Type 3P 4P 3P 4P 6
9 XLS10 XLS12 XLS16 XLS20 XLS25 XLS32 XLS /60 50/60 3, 4 3, 4 0.5~ ~ x x x x x x x x x x x x
10
11 INTELLIGENT TRIP DEVICE
12 MBH ELECTRIC AIR CIRCUIT BREAKER USR-2 USR-6 TYPE USR-2 USR-6 CURRENT RELAY Long & Short Delay, Instantaneous, Ground Fault Long & Short Delay, Instantaneous, Ground Fault, Zone Selective Interlocking ADDITIONAL RELAY - Leakage (external CT) MEASUREMENT FUNCTION - Current (R/S/T/N) PRE TRIP ALARM - Overload Protective Relay DO output (alarm) PTA Ground unavailable when PTA is used COMMUNICATIONS - Modbus / RS-485 POWER Self Powered Turns on when current reaches 20% of rated value Self Powered - Turns on when current reaches 20% of rated value - External power used during the communication AC/DC 110~220V DC 24~48V RTC TIMER Availabe Availabe TRIP DISPLAY LED Long time delay trip - Long time delay - Long/Short Instantaneous time delay - Ground default FAULT RECORD - 10ea display default (phase/current/date/time) EVENT RECORD - 10ea knob setting OPERATION BUTTON - Reset S/I-LTD (menu/move/enter) 10
13 USR-2 OCR A state-of-the-art, high-speed micro controller is used. The current value can be checked; it displays the load factor and the line status. Easy to identify the faults by displaying trip event. (Long-time delay, short-time delay, instantaneous delay, low-voltage, unbalanced current and overheating). LED Displays Trip Data and Overload Status. LED flicker indicates that current exceeds 1.13xIn. LED light remains turned on following the tripping of the breaker. 11
14 MBH ELECTRIC AIR CIRCUIT BREAKER USR-6 OCR Overload Protection: Long Time Delay Protection. Short-Circuit Protection: Short Time Delay & Instanteneous Delay Protection. Ground Fault Protection: ZSI (Zone Selective Interlocking). Function enables easier interlocking for protection. Advanced MCU: Basic measured current. High-precision measurement. Fault Recording Function: 10 cases of fault type, fault phase, fault value and corresponding time log. 4 Digital Outputs (DO). Communication Function: Modbus / RS485. LED Trip Data and Overload Status Indicator. LCD Indicator measurement and data of each phase. RESET KEY Reset after OCR relay operation and after Battery Check. MENU Initial screen, move between setting menus. PTA (Pre Trip Alarm): Overload Protective Relay DO Output. LTD (Long Time Delay): Long Time Delay Relay Operation indicator. STD/INST (Short Time Delay/Instant): Indicators Short Time & Instantaneous Delay Operation. GFT/ELT: Indicators Ground Fault Operation. Alarm: Overload warning alarm (Turns on when load current reaches 0.9xIn. Flickers when current reaches 1.05xIn). LTD Ir: Long Time Delay Current Setting. Tr: Long Time Delay Time Setting. S/I Isd: Short Time Delay Current Setting. Tsd: Short Time Delay Time Setting. li: Instantaneous Time Current Setting. ENTER Move to Lower Menu or Input Setting. MOVE CURSOR Move to Menu or Reset; Left/Right Move of screen cursor or setting. 12
15 RELAY CHARACTERIStics OPERATING CHARACTERISTICS LONG TIME DELAY PROTECTION CURRENT RELAY Tripping between 1.05 & 1.20xl Time delay(s) SHORT TIME DELAY PROTECTION Current Settings (A) Time INSTANTANEOUS DELAY PROTECTION Current Settings (A) Tripping time GROUND FAULT PROTECTION Gorund pick-up(a) Time LEAKAGE PROTECTION (OPTION) Current Settings (A) Time delay(s) lu=lnx... lr=lnx... (1.5xlr) (6xlr) (7.2xlr) lsd=lrx... l2t off l2t on Tsd (max resettable time) Tsd(max break time) li=lrx... max. 50ms lg=lnx... l2t off l2t on Tg (max resettable time) Tg (max break time) lg Tg Long-Time, Short-Time & Instantaneous Delay Protection Ground Fault Protection 13
16 MBH ELECTRIC AIR CIRCUIT BREAKER RELAY CHARACTERIStics LONG TIME DELAY Overload protection. Time delay that is inversely proportional to the fault current. 1. Standard Current Setting Knob:lr 2. Delay Time Setting Knob: tr Operation Time at 6xIr. Setting Stages (9): Off sec. 3. Relay Pick-up Current Pick-up relay current: Relayed at current of (1.15)xIr or higher. 4. Calculation based on the highest load current among R/S/T/N SHORT TIME DELAY Isd tsd Over-current protection. Time delay and definite time that is inversely proportional to the fault current. 1. Standard Current Setting Knob: lsd Setting Stage: ( Off) lr. 2. Delay Time Setting Knob: Tsd Operation Time Standard: Operation Time at 10xIr. Inverse Time (lt On): /sec. Definite Time (lt On): /sec. 3. Calculation based on the highest load current among R/S/T/N. 4. ZSI (Zone Selective Interlocking) Instantaneous relay operation under protective interlocking when ZSI function is set. INSTANTANEOUS TIME DELAY Short circuit protection. When the fault current is above the preset value, it shall be dealt with within the shortest time possible to prevent accidents. 1. Standard Current Setting Knob: li Setting Range : ( Off) lu. 2. Calculation based on the highest phase current. 3. Overall breaking time shall be below 50ms. 14
17 GROUND FAULT DELAY Ground Fault Protection. When the ground current is above the preset value tripping of the breaker will occur. 1. Standard Current Setting Knob: Ig Setting Range : ( Off) ln. 2. Delay Time Setting Knob: tg Inverse Time (lt On): sec. Definite Time (lt On): sec. 3. Ground Current=Vector Sum of R-Phase+S-Phase+ T-Phase+N-Phase. 4. ZSI (Zone Selective Interlocking) Instantaneous relay operation under protective interlocking when ZSI function is set. 5. Ground Fault Protecting Function is included in the basic OCGR type (CT Type built-in). LEAKAGE PROTECTION OPTION Leakage Protection (Optional). When the leakage current is above the set value, it shall be broken after the time delay. 1. Standard Current Setting Knop: Ig Setting Range: Off(A). 2. Leakage (GFT) Trip Time: ms. Alarm Time: ms. 3. External CT used and exclusive for ZCT. 4. Necessity of using external CT Internal CT Type (Basic Type): Ground Fault Protection Protect 20%~100% of the ACB rated current. In case of a large-capacity ACB, the ground fault operating current will also increase. For example, in case of 4000A ACB, the minimum ground fault relay current is 4000A x 20% = 800A. Installation of an external CT is recommended to control the ground sensitivity current, and it is optional to protect the ground fault (leakage). 15
18 MBH ELECTRIC AIR CIRCUIT BREAKER ZONE SELECTIVE INTERLocKING A Zone Selective Interlocking function is intended to protect the load equipments when a fault occurs. It minimizes the delay time and reduces damage to the air circuit breaker and load equipments. Following the operation of short-time delay or ground fault functions, in case of a fault, the concerned protective breaker sends ZSI signal after tripping to prevent upstream breakers from useless tripping. Hence the ZSI enforce continuity of service and reduce downtime of critical loads. In order to eliminate the fault condition, the ACB over-current relay performs an instantaneous trip to clear the fault. The upstream breaker, receiving the ZSI signal, shall refrain from tripping for a short preset time period under the Short-Time Delay or Ground Fault Time Delay functions. Upstream breakers that do not receive the ZSI signal shall trip instantaneously. For proper operation of ZSI, downstream breaker tripping time should be set lower than upstream breaker tripping time under Over-Current, Short Time Delay and Ground Fault Functions. In case of Fault-A: ACB1 independently performs the instantaneous trip. In case of Fault-B: ACB2 performs the instantaneous trip and ACB1 delays till the set time, then perform the instantaneous trip if the fault current is not cleared. 16
19 TRIP CHARACTERISTICS CURVE SHORT-TIME DELAY 17
20 MBH ELECTRIC AIR CIRCUIT BREAKER LONG-TIME DELAY 18
21 INSTANTANEOUS TIME DELAY, GROUND-FAULT t(s) PRE TRIP ALARM (PTA) t(s) *ln *ln 19
22
23 ACCESSORIES
24 MBH ELECTRIC AIR CIRCUIT BREAKER SHUNT TRIP (MX) RATED VOLTAGE (Vn) OPERATING VOLTAGE RANGE (V) POWER CONSUMPTION(VA/W) TRIP TIME(ms) DC(V) AC(V) INRUSH STEADY-STATE 24~ ~1.1Vn 48~ ~1.1Vn 100~ ~ ~1.1Vn ~ ~ ~1.1Vn - 380~ ~1.1Vn * THE AVAILABLE VOLTAGE RANGE IS THE MINIMUM RATING RANGE OF EACH RATED VOLTAGE (VN) WIRE SPECIFICATIONS WIRE TYPE DC 24~30(V) DC/AC 48(V) #16AWG(1.31) #18AWG(0.823) #16AWG(1.31) #18AWG(0.823) OPERATING VOLTAGE 80m 45m 330m 200m 45m 27m 210m 120m Power consumption 200VA, On a new line: Rated Voltage Vn DC 24 ~30V, DC/AC 48V. Recommended maximum wire length. CLOSING COIL (XF) RATED VOLTAGE (Vn) OPERATING VOLTAGE RANGE (V) POWER CONSUMPTION (VA/W) TRIP TIME (ms) DC(V) AC(V) PICK UP DROP OUT INRUSH STEADY-STATE 24~30-48~ ~ ~ ~0.85Vn 0.4~0.6Vn or under 200~ ~ ~480 * THE AVAILABLE VOLTAGE RANGE IS THE MINIMUM RATING RANGE OF EACH RATED VOLTAGE (VN) WIRE SPECIFICATION WIRE TYPE DC 24~30(V) DC/AC 48(V) #16AWG(1.31) #18AWG(0.823) #16AWG(1.31) #18AWG(0.823) OPERATING VOLTAGE 30.5m 18m 155m 95m 25m 15m 135m 80m Power consumption 200VA, On a new line: Rated Voltage Vn DC 24 ~30V, DC/AC 48V. Recommended maximum wire length. 22
25 GEAR (MCH) INPUT POWER DC 24~30V AC/DC 48~60V AC/DC 100~130V AC/DC 200~250V AC/DC 380~480V MOTOR LOAD CURRENT MOTOR ROTATION (RPM) INSULATED WITHSTAND VOLTAGE START LOAD CURRENT (max.) INSULATED WITHSTAND VOLTAGE 5A3A1A0.5A0.3A ~79.000rpm 2kV/min Less than 5 times of the load current 2kV/min OPERATING TEMPERATURE RANGE -20 / -60 DURABILITY CHARGE TIME CHARGE END CONTACT Operating Voltage Range: Voltage 85%~110% cycles (Load Continuous Operating Times: 2times/min) 5 sec or more 15A at 250V AC UNDER VOLTAGE TRIP DEVICE (MN) RATED VOLTAGE (Vn) OPERATING VOLTAGE RANGE (V) POWER CONSUMPTION (VA/W) DELAY TIME (ms) DC(V) AC(V) PICK UP DROP OUT INRUSH STEADY-STATE 48~ ~ ~ ~0.85Vn 0.4~0.6Vn , 2, 3 200~ ~250 FAULT TRIP INDICATION CONTACT (SDE) SDE-2 SDE-6 TYPE RESISTANCE LOAD INDUCTIVE LOAD RESISTANCE LOAD INDUCTIVE LOAD 250V 10A 6A 10A 10A CONTACT CAPACITY NO. OF AVAILABLE CONTACTS AC DC 125V 10A 6A 10A 10A 250V 0.3A 0.3A 3A 1.5A 125V 0.5A 0.6A 10A 6A 125V 0.5A 0.6A 10A 6A Standard OFF - Charge Type, 4a4b AL activates only following an OCR tripping action. The control signal is sent containing fault information. In case of a manual reset-reclosing operation is done after the AL (Alarm) switch is reset. In case of an automatic reset, the AL switch resets after operation of the remote reset device. 23
26 MBH ELECTRIC AIR CIRCUIT BREAKER Manual Reset Button Manual Reset Button (MRB), used to reset the CB allows re-closing following an OCR tripping operation. Operation Counter (CDM) A device used to indicate the number of operations the CB performed. ON / OFF Indication Contact (OF) 4 auxiliary contacts are used to monitor the CB ON/OFF status. Key Lock A lock device used to prevent unauthorized operation of certain CB, when using more than 2 CBs. Lifting Hook A safety device used to easily move CB. Used by attaching the hook to both handles of arc cover. 24
27 Drawout Device (Cradle Mounting Bracket) Mechanical mounting of CB body on the Cradle. Chassis Locking (Pad Lock / Position Lock) ACB is operated in position (CONNECTED, TEST, DISCONNECTED) when drawn-in/out. When the ACB body is drawn-in/out within the cradle, the handle will be locked at an idle status. LOCK is operated when the draw-in button is popped out. LOCK is cancelled by pressing the draw-in button in order to continue the draw-in/out operation. Relay Test Equipment A device to test whether OCR trip relay operates normally without power. Capable to withstand up to 17times the rated current. Input each current, value, size and phase of R/S/T/N. Different line frequencies can be tested. Testing long-time delay, short-time delay, instantaneous, ground fault protection functions. Attached to the door frame. Transparent cover. Mounted on the distribution panel to cover the breaker in order to prevent exposure to dust. Temperature Sensor Send alarm signal via RS-485 if temperature rises above the set operating temperature. Interphase Barrier Ensures phase-phase clearance. 25
28
29 CONTROL CIRCUIT & MECHANICAL INTERLOCK
30 MBH ELECTRIC AIR CIRCUIT BREAKER ELECTRICAL DIAGRAM Auxiliary MN MCH XF OF S/W 28
31 mechanical interlock Switches can be interlocked by using proper mechanical interlocks between the ACBs. Horizontal Type Used for a cable-type mechanical interlocking between 2 draw-out type circuit breakers. The maximum distance between interlocking circuit breakers is 2000mm. Vertical Type Vertical interlock is normally applied using a mechanical connecting nod to the draw-out type circuit breaker and it is used for the mechanical interlocking between 2 circuit breakers. CAUTION: User should refer to manual prior to installing mechanical interlock. SPACE SPACE 29
32 MBH ELECTRIC AIR CIRCUIT BREAKER Fixed Type (2000A) Control Terminal Charge Handle Rating Plate Charge/Discharge Display ON / OFF Display Draw-in/out Handle, Insertion Point Draw-in/out Display Dram-in/out Handle Protection Relay OFF Button ON Button Internal Structure 1 Closing Coil 2 Trip Coil 3 Auxiliary Switch 4 Arc Extinguishing Chamber 5 Main Body of CB 19 6 Charging Handle Mechanism Shaft Closing Spring 9 Draw-out Mechanism Draw-out Cam Moving Contactor Fixed Contactor Load Side Conductor Draw-Out Conductor Circuit Breaker Connection Conductor 16 Power Supply Side Conductor 9 17 Safety Shutter 18 Insulation Mold Body Arc Runner 30
33 CONNECTED TEST DRAW-OUT It is a state where ACB body, main circuit and control circuit are all disconnected. ACB is completely disconnected from cradle. Check whether DISCONNECTED is displayed in the draw-out position display. CONNECTED TEST DRAW-OUT It displays the disconnection state of main circuit, ACB body and the connection state of control circuit. A switching test, Inspection and changing set value of the trip current of the protection relay are possible. Turn draw-out lever till the Test Point. CONNECTED TEST DRAW-OUT It displays the normal connection state of panel board circuit and ACB body. Check whether CONNECTED is displayed in the draw-out position display. 31
34
35 STANDARD APPLICATIONS
36 MBH ELECTRIC AIR CIRCUIT BREAKER OPERATING CONDITIONS Temperature Range Use within the range of max. +40 C and min. -5 C. The average 24-hour temperature should not exceed +35 C. Altitude 2000m or below. Environmental Condition Relative humidity should be lower than 85% at 20 C. Relative humidity should never exceed 90%. Avoid storage in the presence of oil gas, ammonia gas and corrosive gas. Storage Temperature Store it at max. +60 C and min. -20 C. The average 24-hour temperature should not exceed +35 C. Special Operational Environment If the ACB is installed in a high temperature and humid environment, electrical insulation and mechanical performance will be degraded. In this case, it is recommended to increase anti-corrosion resistance. Derating should be considered if ambient temperature exceeds 40 degrees. If the ACB is installed at altitudes above 2000m, heat emission, voltage, conduction capacity and breaking capacity will be reduced. Insulation level will decrease depending on air pressure. C CAUTION: Please consult our representatives for operations outside the specified ambient conditions. 34
37 STANDARD PROTECTION FOR ELECTRICAL NETWORKS Standard use of ACB MBH XLS ACBs are used in a wide range of industrial applications to protect equipment, conductors and devices in low voltage distribution networks. Short Circuit Breaking Capacity Nominal, overloads and short circuit currents must be determined in order to properly select and setup the ACB. The MBH XLS ACB must be properly sized to interrupt the maximum short circuit current as well as the lowest or weakest short circuit current at its point of installation. Protective Features The MBH XLS is equipped with a number of protection functions: Overload Protection Function: This feature allows the user the possibility of accurately adjusting the nominal current setting within the range of 0.5xIe. This feature also enables overload setting Ir. Time Short-Circuit Protection Function: The user must take into consideration the inrush currents, weak short circuit currents and fault current while setting of the Time Short Circuit Protection Function.The MBH XLS is designed to interrupt the faulted current within the required time frame while offering the needed selectivity across multiple levels and avoiding unwanted tripping on normal inrush currents. Instantaneous Short Circuit Protection: This feature enables instantaneous tripping action against high short circuit currents. The user usually sets the tripping current as a multiple of the primary overload adjustment. Ground Fault Protection Function: This feature grants the user the possibility of protection against ground fault currents thus protecting against damages to equipment and personnel. Generator Protection The protection device needs to be adjusted adequately in order to ensure quick and proper response against excessive generator overloading and short circuit conditions. Recommended timed short-circuit setting is 2.5xIr. 35
38 MBH ELECTRIC AIR CIRCUIT BREAKER Motor Protection The user should setup the ACB protective features such as to avoid tripping starting motor current. The following settings for timed short circuit device of a power circuit breaker are recommended: 12xIr with 50ms delay. 12xIe if instantaneous. The overload protection should incorporate a re-energization delay function in order to allow cooling of conductors and motors following an overload period. The user should consider including additional protective functions against motor operational anomalies such as phase loss detection and blocked rotor. Transformer Protection Transformers generally draw high inrush current upon energization. The peak inrush current, during the first half cycle, can reach values up to 15 to 25 times the normal transformer rated current. Protective devices should discriminate between inrush currents and short circuit currents and should not trip during energization. The following settings are recommended for transformer protection: 8xIr delayed 30ms. 15xIe~20xIe instantaneous. IEC TRIP CLASSES Trip Class 1.2xln 1.5xln 7.2xln 10A t<2hours t<2min 2 t<10 10 t<2hours t<4min 4 t<10 20 t<2hours t<8min 6 t<20 30 t<2hours t<12min 9 t<30 36
39 APPLICATION GUIDE Clearance Distances MBH ACB is tailored to break high short circuit current levels in a very short time frame. Breaking such current leads to emission of gas and some debris of conductive fragments. MIN. CLEARANCE FIXED ACB TO HOUSING Metal part Insulated part A B B MIN. CLEARANCE DRAWOUT ACB TO HOUSING Metal part Insulated part A 0 0 B B BUSBAR SIZING Breaker Type CURRENT RATING RECOMMENDED COPPER BUSBAR XLS A 2x60x5 / 1x60x10 XLS A 2x40x10 / 2x80x5 XLS A 2x50x10 / 2x100x5 XLS A 3x50x10 / 3x100x5 XLS A 4x50x10 / 4x100x5 XLS A 4x100x10 XLS A 4x100x10 37
40
41 DIMENSIONS
42 MBH ELECTRIC AIR CIRCUIT BREAKER Fixed Type (2000A) Rated Current T(mm) W(mm) 1200A OR BELOW A A Draw-Out Type (2000A) Rated Current T(mm) W(mm) 1600A OR BELOW A
43 Fixed Type (2500~3200A) Rated Current T(mm) W(mm) 2500A A Draw-Out Type (2500~3200A) Rated Current T(mm) W(mm) 2500A A
44 MBH ELECTRIC AIR CIRCUIT BREAKER Fixed Type (4000A) Rated Current T(mm) W(mm) 4000A Draw-Out Type (4000A) Rated Current T(mm) W(mm) 4000A
45 catalog no. XLS F D M AC2 1 mn Series XLF Air Circuit Breaker F1 F2 F3 Frames 1000A ~ 1250A 1600A ~ 3200A 2500A ~ 4000A Rated Current A 1250A 1600A 2000A 2500A 3200A 4000A No. of Poles 3 3poles 4 4poles Installation Mode F Fixed Type D Draw-Out Type Operation M Motorized H Manual Over Current Trip Isolating Switch USR-2 USR-6 Normal LCD MN MX OF Option Under Voltage Trip Shunt Trip USR External Contact Auxiliary Voltage DC DC 110V AC AC 110V AC2 AC 220V Accessories Voltage *** *** To specify Accessories Voltage. 43
46
47
48 MBH Middle East & Africa Halat, Lebanon T middleeast@mbhelectric.de MBH Gulf Baniyas Complex Nasser Square Al Rigga Area Deira, Dubai, UAE T , F dubai@mbhelectric.de MBH Headquarters MASCHINENBAU HALBERSTADT GmbH Rudolf Diesel-Strasse 50 Halberstadt Germany T , F info@mbhelectric.de Maschinenbau Halberstadt GmbH All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights.
ACB l COMET AIR CIRCUIT BREAKER
ACB l COMET AIR CIRCUIT BREAKER MASCHINENBAU HALBERSTADT GROUP, building on its 60 years legacy in power generation, introduces COMET Air Circuit Breaker designed to meet the standards and the requirements
More informationSpecification for 70mm pole pitch Air circuit breaker up to 1600 A
Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with
More informationCONTENTS. Dimensions A1-57
A1 CONTENTS For industrial and residential Features A1-02 External & Internal Configuration A1-04 Basic Operation/Trip Method/Standards/Certification A1-06 Features A1-08 Ratings A1-10 OC(G)R(Over Current(Ground)Relay)
More informationMemshield - ACB Ratings & Specifications
Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationlow voltage GLOBAL CATALOGUE RANGE ACB Air Circuit Breakers
CATALOGUE GLOBAL RANGE 3. ACB Air Circuit Breakers Inde 3. Air Circuit Breakers 3.1 ACB Product Overview Air Circuit Breakers 3.2-3.3 ACB Product Specifications 3.4 ACB Accessories Overview 3.5 ACB Accessory
More informationNew DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE
New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with
More information5. OVERCURRENT RELEASE (OCR)
5. OVERCURRENT RELEASE (OCR) Options available for the type AR ACBs include a highly reliable, multi-functional overcurrent release (OCR) with a built-in 8- bit microprocessor. This OCR is supplied with
More informationPrisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter
3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice
More information6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection
More informationLow voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue
Low voltage Masterpact NT and NW LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type Catalogue 2015 Functions and characteristics Circuit breakers and switch-disconnectors NT06
More informationPower protection solutions
Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationMasterpact NW DC Circuit Breakers
Masterpact NW DC Circuit Breakers Catalog 0613CT0501 R06/15 2015 Class 0613 CONTENTS Description............................................. Page General Information..........................................
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More information(p. 47) (p. 155) (p. 155)
0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic
More informationCircuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63
Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10
More information(Example) In case of DC24 to 48V, it is operating time for DC24V.
7 9 8 Closing coil (CC) The closing coil is a device to close the breaker by remote control. An interlock to prevent pumping is provided electrically. CC circuit diagram Rated voltage (Applicable voltage
More informationMoulded case circuit breakers
Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationBreaking and protection devices
Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationMasterpact NW DC Circuit Breakers
Masterpact NW DC Circuit Breakers Catalog 0613CT0501R1/07 2007 Class 0613DC CONTENTS Description..............................................Page Contents General Information Line 1.........................................
More informationCharacteristics of LV circuit breakers Releases, tripping curves, and limitation
Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break
More informationDPX 630 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationAir Circuit Breakers. U-Series. Instruction Manual. Type covered in this manual. Notice
U-Series Air Circuit Breakers Instruction Manual Type covered in this manual UAN Type : UAN06, UAN08, UAN10, UAN12, UAN16, UAN20, UAN25, UAN32, UAN40, UAN50 UAS Type : UAS06, UAS08, UAS10, UAS12, UAS16,
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationMasterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A
Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact
More informationOSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage
Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationContents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10
Compact ACB 100A Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics:
More informationContents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10
Compact ACB 100A Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics:
More informationPowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers
PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/14 2014 Class 0612 CONTENTS Description............................................. Page General Information..........................................
More informationME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage
Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More information5. OVERCURRENT RELEASE (OCR)
5. OVERCURRENT RELEASE (OCR) Options available for the type AR ACBs include a highly reliable, multi-functional overcurrent release (OCR) with a built-in 8- bit microprocessor. This OCR is supplied with
More informationSACE Emax 2/ML Low-voltage air circuit breakers for naval applications
LOW VOLTAGE SACE Emax 2/ML Low-voltage air circuit breakers for naval applications 2 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS SACE Emax 2/ML Robustness and reliability up
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationSafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure
2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear
More informationRated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits
7 Technical Data Dielectric strength Circuit Withstand voltage (at 50/60 Hz) Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control
More informationSelection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker
Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationSection Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB
1 Section Contents PAGES 1. Introduction 2-5 Salient features, internal & general appearance of Drawout ACB 2. Ratings & Specifications 6-9 Free air & enclosed thermal current ratings for AC & DC applications
More informationAir Circuit Breakers DH series General information
General information Air circuit breakers Description The newly designed air circuit breakers have excellent features as follows: The height and depth dimensions are identical in all sizes up to 3200AF
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationMotor Protection Circuit Breakers 3VU13 and 3VU16
Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection
More informationContents. We build a better future! MCC HCB
H8PU Low Voltage We build a better future! HYUNDAI s low voltage motor control center H8PU series with a withdrawable unit are of multi-tier, factory assembled and for rated voltage of up to 660V AC. Contents
More informationDATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT
44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7
More informationINSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)
INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR650S, AR663S, AR663H Notice Be sure to read this manual before installing,
More informationDPX 160 Thermal magnetic and trip-free switches DPX-I 160
87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationPIX-H Metal-clad switchgear up to 17.5kV
AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationKD LV Motor Protection Relay
1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage
More informationINSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device)
INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) Types: KA208S KA212S KA216S KA220S KA325S KA332S KA440S KA212H KA216H KA220H KA316H KA320H
More informationACW Molded-Case Circuit Breaker UL 489 Listed
Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current
More informationACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence
rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial
More informationEssential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.
The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.
More informationMagnum IEC Low Voltage Air Circuit Breakers
Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven
More informationSubmittal Data Information
Effective: NOVEMBER 3, 2014 JOB CONTRCTOR ITEM NO. Submittal Data Information TS - Taco dvanced Starter ENGINEER REP. 301-2690 Supersedes: NEW TS - Taco dvanced Starter 1Ø, 120-230V, 1/10-30HP 3Ø, 200-600V,
More informationIntroduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction
Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection
More informationLow voltage moulded case circuit breaker EB2
Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation
More informationLSIS UL MCCB & Accessory
LSIS UL MCCB & Accessory UL MCCB 100/150/250/400/600/800/1200AF UL MCCB Accessory 100/150/250/400/600/800/1200AF No. Specification 100AF 150AF 250AF 400AF 600AF 800AF 1200AF 1 2 3 4 5 6 7 8 9 10 11 12
More informationAir Circuit Breaker Instruction Manual
Innovators in Protection Technology Air Circuit Breaker Instruction Manual AGR-31B Overcurrent Protection Device 06-M55EC INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B
More informationINSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)
INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR208S AR212S AR216S AR220S AR325S AR332S AR440S AR440SB AR212H AR216H
More informationGE Consumer & Industrial. M-PACT New Air Circuit Breaker A
GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationProtection and Connection Motorized and automatic transfer switches IEC Technical guide
Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety
More informationManual motor starters Overview and benefits
Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection
More informationLow Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A
Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection
More informationShort-circuit current limiter S800-SCL-SR
Short-circuit current limiter S800-SCL-SR 2 ABB Short-circuit current limiter S800-SCL-SR Self-resetting current limiting module S800-SCL-SR is ABB s innovative self-resetting current limiting module which
More informationPowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers
PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/16 2015 Class 0612 CONTENTS Description............................................. Page General Information..........................................
More information3VU13, 3VU16 Circuit-Breakers
3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used
More informationSafeGear TM Motor Control Center Arc resistant metal-clad construction
SafeGear TM Motor Control Center Arc resistant metal-clad construction Contents Description 2 SafeGear TM MCC applications 3 Electrical features 3 Standards 3 Standard service conditions 4 HCV vacuum contactor
More informationMedium voltage vacuum circuit breaker. E-VAC series
Medium voltage vacuum circuit breaker E-VAC series Product description E-VAC vacuum circuit breaker Contents Description Product description... Technical data... Dimensions... Wiring diagram... E-VAC series
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationModular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide
GE Industrial Solutions Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide TABLE OF CONTENTS Description Page 1.0 General Information...... 1 1.1 Protection..... 1 2.0 UL Listed Devices...
More information01 Spectra Plus - Introduction
01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More information3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers
.1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size
More informationMotor Protection Circuit Breakers
Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions
More informationCascading & Discrimination
Cascading & Discrimination Typical LV System Level 1 ACBs - 6300A General LV Switchboard Level 2 ACB - 3200A MCCB 3200A Level 3 MCCB 1250A Fuses 630A Switchboard, Panelboard or MCC Level 4 MCBs - 100A
More informationApplication Description
-14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....
More informationNew range of reclosing systems
Protection and Control RECmax New range of reclosing systems Earth leakage and circuit breaker protection with automatic earth leakage reclosing system. Manage its installation remotely Energy efficiency
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationWORKSHOP SPECIFICATIONS
WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide
More informationCircuit protection and control devices 0.5 to 6300 A
Electrical distribution Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2009 m TOOLS schneider-electric.com The technical guide This international site allows you to access
More informationLow Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge.
Vacuum Contactor HYUNDAI Vacuum Contactors are designed and manufactured for frequent switchings, especially taking into account safety and quality assurance. They are suitable for switching and controlling
More informationAutoLink Frequently Asked Questions
Rev. 3 October 2013 Page 1 of 8 AutoLink Frequently Asked Questions October 2013 1 Rev. 3 October 2013 Page 2 of 8 Table of Contents 1 Background... 4 1.1 What is the AutoLink Single Phase Electronic Sectionalizer?...
More informationData Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M
Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M MS50T3L M2N200T3L na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit
More informationData sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443
CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationCDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.
Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit
More informationAir Circuit Breakers
Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More information