1 Compact ACB 100A
2 Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10
3 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics: 0kA/4Vac Ics=100%*Icu) Cat.B ~100A Rated breaking time : cycle Short time withstand current : 50kA/1sec (Cat.B) Mechanical life cycle(without maintenance) : 12,500(Cat.B), 5,000(Cat.A) Cradle : Standard type(bottom operating) Various operating(control) powers - DC 24/V, AC/DC110V, DC125V, AC/DCV, AC 80V Accessories - ACB: UVT, Ready to Close S/W, Remote reset coil(res), Rating Plug, Manual Reset Button, Counter, ON/OFF Button Lock, Key Lock, etc. - Cradle: MOC(Mechanism Operating Cell s/w), Cell S/W(Cradle Position Cell s/w), Mechanical Interlock, Door Interlock, Position Keylock, Padlock/Position Lock, Safety Shutter, etc. Standards IEC DEKRA CB & CCC Certificates (Test for the certificates is expected to be finished in Jun.) Ratings Common Characteristics Number of poles (P) P/4P Frequency (Hz) 50/0Hz Rated operating voltage (V, Ue) V Rated insulation voltage (V, Ui) 1000V Rated impulse withstand voltage (kv, Uimp) Circuit Breaker as per IEC Type 12kV AN/AH/AR-C Description AN-1C AH-1C AR-10C Ampere Frame (AF) Rated current (In Max.) at 40 (A) (A) (A) (A) (A) (A) Rated current of neutral pole (A) Rated breaking capacity (Icu) (ka) IEC AC V/00V/0V 50 - AC 500V/0V AC 4V/80V/0V 50 - AC 4V/80V 0 50 AC 240V/V 0 Rated breaking capacity (Ics) (ka,% Icu) 100% Rated making capacity (Icm) (ka) /18. - Rated Short-time capacity (Icw) (ka) 1sec 42/ Operating time (t) (ms) Common Mechanical and Electrical Life Cycle Life cycle (time) Common Demension and Weight Weight (P/4P) Dimension (P/4P) (kg) (mm) Draw-out type (P/4P) 1/19.5 Fixed type (P/4P) 1/19.5 Draw-out type (H : 1., D : 257) Fixed type (H : 28, D : 185.) Total breaking time 40 Closing time Mechanical 12,500 5,000 Electrical,000,000 Cradle (P/4P) 22/2 W(P/4P) 2.4/2 W(P/4P) 272.4/42.4 I
4 Ordering AN-1C-10J M1 D1 D1 FX NG0 Motor rated voltage MA Without Motor M1 AC/DC 100V ~ 10V M2 AC/DC 200V ~ 250V M DC 125V M4 DC 24V ~ 0V M5 DC V ~ 0V M AC 80V ~ 4V M7 AC 0V ~ 0V M8 AC V Closing coil rated voltage D0 D1 D2 D D4 D5 D D7 Without Closing coil AC/DC 100V ~ 10V AC/DC 200V ~ 250V DC 125V DC 24V ~ 0V DC V ~ 0V AC 80V ~ 0V AC V Shunt coil rated voltage D0 Without Shunt coil D1 AC/DC 100V ~ 10V D2 AC/DC 200V ~ 250V D DC 125V D4 DC 24V ~ 0V D5 DC V ~ 0V D AC 80V ~ 0V D7 AC V Auxiliary switch with charging type FX Standard 4C with "OFF" charging type FC Standard 4C with "ON" charging type SC Standard 4C with "ON" charging type for TCS type * TCS : Tripping coil supervision 0 Without trip relay N OCR TYPE N NORMAL 0 Without trip relay G Communication & protection G Ground fault (Residual earth fault protection), No Communication * L,S,I,G configuration as standard (with LED indicators) 0 Without trip relay 0 Control voltage & frequency 0 Self-Power, 0Hz 5 Self-Power, 50Hz A A OCR TYPE Ammeter G E C X * Comm. And output contacts DO NOT work under self-power condition. (AC0, AK0, AX0, AC5, AK5, AX5) * Communication and output contacts for L,S,I,G do not work except OCR LED without control power supply. - AG0, AG5, AZ0, AZ5, AE0, AE5 G Communication & protection Ground fault (Residual earth fault protection), No Communication Earth Leakage(Extermal CT), No Communication Communication + Ground fault (Residual earth fault protection) Communication + Earth Leakage(Extermal CT) 0 Control voltage & frequency 0 Self-Power, 0Hz 1 AC/DC 110V~V, 0Hz 2 DC 24V~V, 0Hz 5 Self-Power, 50Hz AC/DC 110V~V, 50Hz 7 DC 24V~V, 50Hz P P OCR TYPE Power meter C X * Communication functions are Normal. (Function unavailable without control power supply) * Applicable to generator protection purpose * Voltage module of P type or more is basic. G Communication & protection Communication + Ground fault (Residual earth fault protection) Communication + Earth Leakage(Extermal CT) 0 Control voltage & frequency 1 AC/DC 110V~V, 0Hz 2 DC 24V~V, 0Hz AC/DC 110V~V, 50Hz 7 DC 24V~V, 50Hz S S OCR TYPE Supreme meter C X * Communication functions are Normal. (Function unavailable without control power supply) * Applicable to generator protection purpose * Voltage module of P type or more is basic. G Communication & protection Communication + Ground fault (Residual earth fault protection) Communication + Earth Leakage(Extermal CT) 0 Control voltage & frequency 1 AC/DC 110V~V, 0Hz 2 DC 24V~V, 0Hz AC/DC 110V~V, 50Hz 7 DC 24V~V, 50Hz N N OCR TYPE NORMAL V Pre-Trip Alarm * Ground fault detection is basic. (Internal CT Vector Sum system) * L,S,I,G configuration as standard (with LED indicators) V Communication & protection 1 Control voltage & frequency 1 AC/DC 110V~V, 0Hz AC/DC 110V~V, 50Hz 4I
5 U1 AL / C U0 U1 U2 U U4 U5 U U7 UVT coil rated voltage Without UVT coil AC/DC 100V ~ 10V AC/DC 200V ~ 250V DC 125V DC 24V ~ 0V DC V ~ 0V AC 80V ~ 0V AC V * UVT Delay module is available over AC / DC V Character AL A1 A A4 A5 A7 A8 A9 Option Table Option name AL1 + MRB AL1 + MRB + RES(AC110~10V) * AC private use AL1 + MRB + RES(DC110~125V) * DC private use AL1 + MRB + RES(AC200~250V) ** AC private use AL1 + MRB + Auto Reset AL1 + MRB + RES(DC110~125V) + Auto Reset * DC private use AL1 + MRB + RES(AC200~250V) + Auto Reset * AC private use AL1 + MRB + RES(AC110~10V) + Auto Reset * AC private use C C COUNTER **AH only B B On/Off Button lock M MI Mechanical interlock **AH only D DI or MOC Mechanism operated cell switch K K1 Key Lock K2 K2 Key Interlock Set R RCS Ready to Close switch T TM Temperature Monitoring **AH only H1 H2 H H4 H5 H H7 SHT2 Note 1) AC/DC 100V ~ 10V AC/DC 200V ~ 250V DC 125V DC 24V ~ 0V DC V ~ 0V AC 80V ~ 0V AC V Note 1) UVT and SHT2 can not be selected together, Select one of two. Note 2) Codes for over 5 optional accessories are composed separately N01 N02 N0 N04 N05 A4 (AL1 + MRB + RES(AC200~250V))+C(Counter)+B(ON/OFF Button Lock) +K(Key Lock)+R(Ready to Close switch)+m(mechanicl Interlock)+E(Spring Auto Release) AL (AL1 + MRB)+K(Key Lock(OFF Lock))+R(Ready to Close switch)+d(door Interlock or MOC) +H1(AC/DC 100V ~ 10V, Double Shunt coil)+e(spring Auto Release) C(Counter)+B(ON/OFF Button Lock)+K2(Key Interlock Set)+R(Ready to Close switch)+t(temperature Monitoring) A4(AL1 + MRB + RES(AC200~250V))+B(ON/OFF Button Lock)+K(Key Lock(OFF Lock))+M(Mechanical Interlock) +T(Temperature Monitoring) A1(AL1+MRB+RES110~10V)+B(ON/OFF Button Lock)+K(Key Lock(OFF Lock))+R(Ready to Close switch)+m(mechanical Interlock)+T(Temprature Monitoring)Interlock)+T(Temprature Monitoring) AN / AH / AR - 1 C 10 J Automatic circuit breaker AN/AH AR Ampare Frame E(CT Spec.) AF 1 100AF AF Phasing C : 800~100AF /4P Standard (N)RST V : 800~100AF 4P Reversed RST(N) Poles : P(C) 4 : 4P(C,V) Rated current 00 None A 0 0A A A A J S T Connections Drawout Bottom operating (Auto Connect) Bottom operating Side operating (Auto Connect) Side operating AF A Fixed 1 100A H Horizontal terminals 00 None V Vertical terminals A M Horizontal for line, Vertical for load 0 0A N Vertical for line, Horizontal for load A P Front terminal A Z Horizontal with speaders * 1) AR can be selected up to Ampere Frame 1000AF. * 2) AR can be selected up to 1000AF(CT Spec.) R T Vertical with spreaders Front connection via vertical connection adapters fitted with cable-lug adapter X Cable Lug I 5
6 Electrical diagram Internal / External wiring (by customer) Connector of the control circuit terminal of drawout type V1 Voltage Module Temperature Power supply Module ZSI Output ZSI Input Reset Common ACB This diagram is based on CONNECTED position of a circuit breaker and Opening, Motor charging, Releasing of locking plate should be normal condition. ZCT V2 V VN E1 Z Z1 5+ R11 R22 51 R2 R /RES(+) D1 C11 C1 A1 U2 U Trip relay UVT SHT2 SHT1 CC M Temperature Sensor-1 Temperature Sensor-2 or E2 Z4 Z /RES(-) D2 C12 C2 A2 U Main circuit Digital trip relay Alarm Contact Ready to close Electrical operation circuit Secondary trip coil Charge completion contact Auxiliary switch Thermal, communication remote control module UVT ON T1 TC1 T2 TC2 OFF OFF ON Charged OFF Terminal code description Accessory code description U1 U1 A1 C U2 U4 A2 C2 ~ ~ 42 Auxiliary switch "b" contact Auxiliary switch "a" contact Charge completion signal Motor charging Closing coil Shunt trip D1 D2 C11 C12 2nd shunt trip R11 R22 Alarm reset (Trip cause LEDs, contacts) R1 51 ~ R2 514 Voltage input terminal of UVT coil Alarm1 "b" contact Alarm2 "b" contact or RES Coil Ready to close switc Control power for trip unit Fault cause indication contacts 5+ Z1 Z E1 VN TC1 5- ~ ~ Z2 Z4 E2 TC2 V ~ T1 T2 Note) 1. The diagram is shown with circuit de-energized, all devices open and charged and relays in normal position 2. Relay is normal condition and charging type is "Off-Charging". The standard of auxiliary contact is 4C. The auxiliary switch in above diagram is composed of 4C. See page for more detail on auxiliary switches. 4. Option - Ready to close contact, Trip alarm contact, UVT coil, Fully charged contact, secondary trip coil - Temperature module, Voltage module, ZCT, ZSI 5. Please consult us for the use of ZSI (Zone selective Interlocking).. Refer to the page for the connection of Trip relay and the page 4 for UVT. 7. For connecting RS-5 verify if the polarity is correct RS-5 communication ZSI input ZSI output ZCT Voltage module Temperature module Cell switch Ax LTD STD/Inst GTD CL1~CL4 M CC SHT1 SHT2 UVT Auxiliary switch Long time delay trip indicator Short time delay/instantaneous Ground fault trip indicator Cell switch Motor Closing coil 1st Shunt coil 2nd Shunt coil UVT coil I
7 Trip Coil Supervision(Option) C1 A1 U2 U SHT1 CC M C2 A2 U Electrical operation circuit Charge completion contact Auxiliary switch OFF ON CL4 (DISCON) or CL4 (TEST) CL (TEST) CL2 (CONNECTED) CL1 (CONNECTED) CL8 (DISCON) CL7 (TEST) OFF ON Charged OFF ON CL (CONNECTED) CL5 (CONNECTED) Axc Axc Axc Axc Cell switch 4C Cell switch 8C (4C Addition) MOC (Mechanical Operated Cell switchs) Terminal code description ~ ~ Cell switch MOC Note) 8. Contact configuration for Cell Switch can be changeable if necessary I 7
8 Accessories Main ACB ACB Trip Relay(OCR) Under Voltage Trip Device(UVT) Auxiliary Switch(AX) Miss Insertion Preventing Device Motor(M) Ready to Close switch(rcs) Key Lock(K1) (MIP) Closing Coil(CC) Door Interlock(DI) Counter(C) Manual Reset Button(MRB) Shunt Coil(SHT) Mechanical Operated Cell SW(MOC) ON/OFF Button Lock(B) Cradle Cradle Safety Shutter(ST) Mechanical Operated Cell SW(MOC) OCR Tester(OT) Remote Close Open(RCO) Insulation Barrier(IB) Miss Insertion Prevent Device(MIP) Dust Cover(DC) Lifting Hook(LH) Cell SW(CEL) Racking Interlock & Position Lock(RI) Door Frame(DF) Door Interlock(DI) Condensor Trip Device(CTD) UVT Time Delay Controller(UDC) 8I
9 Structure Lower type cradle (Main-Type) Side bracket (Lower type) [ Compact ACB 100A Cradle Structure ] I 9
10 Dimensions Fixed Type (Front view) AN/AH/AR-C P/4P Fixed Type(Horizontal type) AN/AH/AR-C P R Fixed Type(Horizontal type) AN/AH/AR-C 4P R I
11 Fixed Type(Front view) AN/AH/AR-C P/4P Fixed Type(Vertical Type) AN/AH/AR-C P R Fixed Type(Vertical Type) AN/AH/AR-C 4P R I 11
12 Dimensions Draw-out Type(Front view) AN/AH/AR-C P/4P Draw-out Type(Horizontal type) AN/AH/AR-C P 12I 18.5 Disconnected 4.5 Test Disconnected18.5 Disconnected 4.5 Test 4.5 Test Disconnected 18.5 Disconnected 4.5 Test 4.5 Test Disconnected Test Draw-out Type(Horizontal type) AN/AH/AR-C 4P (Insul bar
13 Draw-out Type(Front view) AN/AH/AR-C P/4P 18.5 Disconnected 4.5 Test 18.5 Disconnected Test Disconnected18.5 Disconnected 4.5 Test 4.5 Test 18.5 Disconnected 18.5 Disconnected 4.5 Test 4.5 Test Draw-out Type(Vertical Type) AN/AH/AR-C 4P Draw-out Type(Vertical Type)AN/AH/AR-C P I 1 (Insulati barrier
14 MEMO 14I
15 I
16 Head Quarter 127 LS-ro (Hogye-dong) Dongan-gu, Anyang-si, Gyeonggi-Do, 119, Korea Tel , 4, 29 Fax: Overseas Subsidiaries LSIS(Dalian) Co., Ltd. (Dalian, China) Tel: Fax: LSIS(Wuxi) Co., Ltd. (Wuxi, China) Tel: Fax: LS VINA Industrial Systems Co., Ltd (Hanoi, Vietnam) Tel: Fax: LSIS Middle East FZE (Dubai, U.A.E.) Tel: Fax: LSIS Europe B.V. (Amsterdam, Netherlands) Tel: Fax: LSIS Japan Co., Ltd. (Tokyo, Japan) Tel: Fax: LSIS USA Inc. (Chicago, U.S.A) Tel: Fax: Overseas Branches LSIS Shanghai Office (China) Tel: Fax: LSIS Beijing Office (China) Tel: Fax: LSIS Guangzhou Offce (China) Tel: Fax: LSIS Qingdao Office (China) Tel: Fax: LSIS Chengdu Office (China) Tel: Fax: LSIS ShenYang Office (China) Tel: Fax: LSIS Jinan Office (China) Tel: Fax: LSIS Co., Ltd. Tokyo Office (Japan) Tel: Fax: LSIS Co., Ltd. Rep. Office (Vietnam) Tel: LSIS Moscow Office (Rossia) Tel: Fax: LSIS Jakarta Office (Indonesia) Tel: Specifications in this catalog are subject to change without notice due to c7. 5 LSIS Co.,Ltd. All rights reserved. / English (01) Staffcom continuous product development and improvement.
Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10
Compact ACB 100A Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics:
More informationMiniature Circuit Breakers BK63HU / BK63H
Miniature Circuit Breakers BK63HU / BK63H BK63H UL89 Ratings BK63HU 1P BK63HU 2P BK63HU 3P Performance UL89 Standard UL89, UL86E(Lug) Protection Overload, Short circuit Rated current 1, 2, 3,, 5, 6, 8,
More informationUp to 24kV Modular type Air insulated switchgear
Up to 24kV Modular type Air insulated switchgear Contents Features 03 General characteristics 04 Units for function 05 Units for dimensions 06 Configuration 09 Ratings - SM VCB 10 A variety of accessories
More informationHigh Voltage DC Relay
High Voltage DC Relay High Voltage DC Relay Leading you toward a greater future than you imagine Leading Innovation, Creating Tomorrow With over 3 years of experience in electric power and automation solutions,
More informationACB l COMET AIR CIRCUIT BREAKER
ACB l COMET AIR CIRCUIT BREAKER MASCHINENBAU HALBERSTADT GROUP, building on its 60 years legacy in power generation, introduces COMET Air Circuit Breaker designed to meet the standards and the requirements
More informationCONTENTS. Dimensions A1-57
A1 CONTENTS For industrial and residential Features A1-02 External & Internal Configuration A1-04 Basic Operation/Trip Method/Standards/Certification A1-06 Features A1-08 Ratings A1-10 OC(G)R(Over Current(Ground)Relay)
More informationlow voltage GLOBAL CATALOGUE RANGE ACB Air Circuit Breakers
CATALOGUE GLOBAL RANGE 3. ACB Air Circuit Breakers Inde 3. Air Circuit Breakers 3.1 ACB Product Overview Air Circuit Breakers 3.2-3.3 ACB Product Specifications 3.4 ACB Accessories Overview 3.5 ACB Accessory
More informationPrime-MEC LS HRC Power Fuses
www.lsis.biz Prime-MEC LS HRC Power Fuses Current without Power Fuse (ka ms) Ipeak Let through current Below 0.5 Cycle Rated voltage(kv) 3. 7. Initiation of arcing(degree) 5 5 90 5 70 9 7 5 5 Ipeak(kA).5
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationLeader in Electrics & Automation SOLUTION Power Transmission & Distribution
Leader in Electrics & Automation Power Transmission & Distribution Being Created by Diversified Industrial Electricity Technology Stabilized Power Supply and Maximization of Energy Efficiency Where there
More informationMemshield - ACB Ratings & Specifications
Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY
More information(Example) In case of DC24 to 48V, it is operating time for DC24V.
7 9 8 Closing coil (CC) The closing coil is a device to close the breaker by remote control. An interlock to prevent pumping is provided electrically. CC circuit diagram Rated voltage (Applicable voltage
More informationSpecification for 70mm pole pitch Air circuit breaker up to 1600 A
Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with
More informationManual Motor Starters
Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More information(p. 47) (p. 155) (p. 155)
0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic
More informationACB l COMET AIR CIRCUIT BREAKER
ACB l COMET AIR CIRCUIT BREAKER MASCHINENBAU HALBERSTADT GmbH, building on its 60 year legacy in power generation, introduces COMET Air Circuit Breaker designed to meet the standards and the requirements
More informationSolution Power Medium Voltage Metal Clad Switchgear
www.lsis.biz Solution Power Medium Voltage Metal Clad Switchgear Contents Features 12 Ratings 14 Structures and dimensions 16 Accessories and apparatuses 18 Arrangement (for general application) 22 2I
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationLow Voltage Air Circuit Breakers 630AF~6300AF 15A
Low Voltage Air Circuit Breakers 6AF~60AF A Mitsubishi Presents the WS Series, Satisfied with the High Demands of the st Century Global Market. Best-Solution Various line-up and high flexibility High-Performance
More informationCircuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63
Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10
More information6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationTri-MEC Load Break Switch
Leader in Electrics & Automation Tri-MEC Load Break Switch Electric Equipment Leader in the field of industrial electricity & automation creating the comfortable and productive society through providing
More informationTechnical Data Accessories MCBs Ex9B.
Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO
More informationBREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker
BREAKER Molded Case Circuit Breaker/Earth Leakage Circuit Breaker 2 BREAKER With an improved technology and agressive invesment in R&D, DAERYUK create differentiated value for each customer in order to
More informationSF6 Gas Insulated Ring Main Unit RMU. A Compact switchgear solution for secondary power distribution networks. Super Solution.
www.lsis.biz SF6 Gas Insulated Ring Main Unit RMU A Compact switchgear solution for secondary power distribution networks. Super Solution Ring Main Unit Ring Main Unit The best solution for Power Distribution
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationNew DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE
New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with
More informationACB/ATS Air Circuit Breaker / Automatic Transfer Switch
ACB/ATS Air Circuit Breaker / Automatic Transfer Switch ACB/ATS Air Circuit Breaker / Automatic Transfer Switch CREATING VALUE 02_03 No matter where you are in the world or in which industrial field, Daeryuk
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationSolution Power Medium Voltage Metal Clad Switchgear
www.lsis.biz Solution Power Medium Voltage Metal Clad Switchgear Contents Features 12 Ratings 14 Structures and dimensions 16 Accessories and apparatuses 18 Arrangement (for general application) 22 2I
More informationLSIS UL MCCB & Accessory
LSIS UL MCCB & Accessory UL MCCB 100/150/250/400/600/800/1200AF UL MCCB Accessory 100/150/250/400/600/800/1200AF No. Specification 100AF 150AF 250AF 400AF 600AF 800AF 1200AF 1 2 3 4 5 6 7 8 9 10 11 12
More information3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers
.1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationLSIS Electric Products. ACB / MCCB / MCB / MC&TOR / Mini-MS / MMS / EMPR
LSIS Electric Products ACB / MCCB / MCB / MC&TOR / Mini-MS / MMS / EMPR Susol series 85, 100 and 130kA short circuit current with instantaneous at 508V High functional digital trip relays UL approved Page
More informationWorld Super Series WSS The extensive breaker series from Mitsubishi Electric
MODEL PUSH TO TRIP TEST 3 P IEC60947-2 JIS C 8201-2 Ue 690VAC 00VAC 440VAC 41VAC 400VAC 380VAC 230VAC T Ir Ip Is Ts EN60947-2 40 C Icu/Ics 8/8kA 30/30kA 8/8kA MODEL POLE Ui 690VAC 0-60Hz 8kV Uimp PUSH
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationSelection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker
Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size
More informationBreakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary
Breakers and Switches Tmax XT Moulded-case circuit-breakers Simply extraordinary Tmax XT Simply extraordinary ABB is proud to present you the result of a long and intense research and development project:
More informationDPX Magnetic only
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY
More informationLow voltage circuit breakers
Catalogue 2007 Super Solution Low voltage circuit breakers The Challenges and Growth achieved by LG will continue with New Will of LS Industrial Systems. New Name for LG Industrial Systems, New Take-off
More informationINSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)
INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR208S AR212S AR216S AR220S AR325S AR332S AR440S AR440SB AR212H AR216H
More informationSuper Solution Retrofit VCB Vacuum Circuit Breakers
www.lsis.com Super Solution Retrofit VCB Vacuum Circuit Breakers Susol VCB Susol VCB is full line-up new VCB which has the high interrupting capacity, large current(~50ka, ~4000A), and maximized compatibility
More informationLV & MV Circuit Breakers, Contactors & Overload Relays
LV & MV Circuit Breakers, Contactors & Overload Relays Globalization of Technology HG-Series, has been an upgraded to better performance and great customer experience. A new premium line of modern low
More informationOSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage
Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :
More informationGE Consumer & Industrial. M-PACT New Air Circuit Breaker A
GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationUTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB
PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L
More informationINSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)
INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR650S, AR663S, AR663H Notice Be sure to read this manual before installing,
More informationHigh Breaking Capacity
Air Circuit Breaker Small Light Weight High Breaking Capacity High Ability Digital APR Safety Convenience HiAN 2000 ~ 3200AF HiAN 6 ~ 1600AF CONTENTS HiAN Type 04 - Feature 06 - Rating 08 - Selection of
More informationDPX Electronic + earth leakage
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL
More informationSuper Solution Air Circuit Breakers
www.lsis.biz Super Solution Air Circuit Breakers ACB LSIS Made It! Susol Air Circuit Breakers Super Solution Contents Overview External configuration Internal configuration Ordering Ratings Trip relays
More informationMCCB Accessories to suit AF
MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage
Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144
More informationINSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device)
INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) Types: KA208S KA212S KA216S KA220S KA325S KA332S KA440S KA212H KA216H KA220H KA316H KA320H
More informationComprehensive Catalogue. Super Solution. Air Circuit Breakers
Comprehensive Catalogue 08 Super Solution Air Circuit Breakers ACB LS Industrial Systems Made It! Susol Air Circuit Breakers Super Solution Contents Overview External configuration Internal configuration
More informationDATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT
44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7
More informationDPX 160 Thermal magnetic and trip-free switches DPX-I 160
87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationSection Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB
1 Section Contents PAGES 1. Introduction 2-5 Salient features, internal & general appearance of Drawout ACB 2. Ratings & Specifications 6-9 Free air & enclosed thermal current ratings for AC & DC applications
More informationDPX 630 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationLow voltage circuit breakers
Catalogue 2009 Super Solution Low voltage circuit breakers The Challenges and Growth achieved by LG will continue with New Will of LS Industrial Systems. New Name for LG Industrial Systems, New Take-off
More informationBreaking and protection devices
Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply
More informationLow Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge.
Vacuum Contactor HYUNDAI Vacuum Contactors are designed and manufactured for frequent switchings, especially taking into account safety and quality assurance. They are suitable for switching and controlling
More informationPowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers
PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/14 2014 Class 0612 CONTENTS Description............................................. Page General Information..........................................
More informationDPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationLOW-VO L TAGE POWER DISTRIBUTION PRODUCTS
LOW-VO L TAGE POWER DISTRIBUTION PRODUCTS Low-voltage Magnetic Contactor Starters 662 Our Power Distribution Products are compact, easy-to-use, built with safety in mind, including the full lineup of Low-voltage.
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationLow voltage circuit breakers
Comprehensive Catalogue 2006 Super Solution Low voltage circuit breakers A-3. Accessories TD & TS MCCB Index Electrical auxiliaries Undervoltage release, UVT Shunt release, SHT Auxiliary switch (AX),
More informationCDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.
Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit
More informationPrisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter
3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice
More informationMasterpact NW DC Circuit Breakers
Masterpact NW DC Circuit Breakers Catalog 0613CT0501 R06/15 2015 Class 0613 CONTENTS Description............................................. Page General Information..........................................
More informationCircuit Breakers Ex9M
Circuit Breakers Ex9M Moulded Case Circuit Breakers Frame size M1 with rated current up to 125 A Frame size M2 with rated current up to 250 A 3-pole versions Rated ultimate short circuit breaking capacity
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationINSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device)
INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) Types: AR208S AR212S AR216S AR220S AR325S AR332S AR440S AR440SB AR212H AR216H AR220H AR316H
More informationLow voltage circuit breakers
Super Solution North American Edition Low voltage circuit breakers Contents Overview Main characteristics Accessories Technical information Mounting & connection Characteristics curves Dimensions A-1 A-2
More informationHYUNDAI U-Series. Molded Case Circuit Breaker
HYUNDAI U-Series Molded Case Circuit Breaker U-Series Molded Case Circuit Breaker Wide and Powerful Range UAB, UCB [ up to 1600AF ] Compact Size High breaking capacity in 60mm depth, up to 2AF Application
More informationTmax Molded Case Circuit Breakers
Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More informationMV Air Insulated Switchgear TAP17. Technical Data TGOOD
MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)
More informationAir Circuit Breaker Instruction Manual
Innovators in Protection Technology Air Circuit Breaker Instruction Manual AGR-31B Overcurrent Protection Device 06-M55EC INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B
More informationMolded case circuit breakers
Molded case circuit breakers Metasol 30F to 250F Series Type Type and Pole Rated current, In Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Frame Size(F)
More informationCircuit protection and control devices 0.5 to 6300 A
Electrical distribution Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2009 m TOOLS schneider-electric.com The technical guide This international site allows you to access
More informationMagnum IEC Low Voltage Air Circuit Breakers
Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven
More informationPricing and selection guide. Emax. Low voltage power circuit-breakers
Pricing and selection guide Low voltage power circuit-breakers power breakers Power Breakers...1 -.74 General information...1 UL...11 IEC...19 Trip units and rating plugs...29 Accessories...31 Dimensions...37
More informationPRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004
PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3
More informationThe effective choice The benefits of a product with the highest quality standards
The effective choice The benefits of a product with the highest quality standards Compact size for easy installation in small spaces and retrofitting of already existing facilities. Terminals designed
More informationAir Circuit Breakers DH series General information
General information Air circuit breakers Description The newly designed air circuit breakers have excellent features as follows: The height and depth dimensions are identical in all sizes up to 3200AF
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationPower Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear
Power Systems PU HYOSUNG Standard High-voltage Switchgear ProSWGR Medium Voltage Metal-clad Switchgear Power & Industrial Systems Performance Group Hyosung Power Systems has been continuously enhancing
More informationACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence
rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial
More information3VT Kompaktleistungsschalter bis 630A
Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical
More informationTmax Molded Case Circuit Breakers
Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More informationCompact NR630. NR100F to NR630F
Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More information