Molded case circuit breakers
|
|
- Everett Parsons
- 5 years ago
- Views:
Transcription
1 Molded case circuit breakers Metasol 30F to 250F Series Type Type and Pole Rated current, In Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Frame Size(F) Rated shortcircuit breaking capacity(icu) k (Sym), KSC8321, IEC C DC Service breaking capacity(%icu), Ics Category of use Endurance (Number of operations) Type of trip unit release Hydraulicmagnetic release Note) 1. applicable or available 2. available as a separate breaker C(V) DC(V) V kv 90V 480/500V 415/40V 380V 220/250V 500V(3P) 250V(2P) Mechanical Electrical Magnetic release only without thermal trip Earth leakage protection ccessories Electrical auxiliaries External accessories Dimensions (mm) Weight(kg) for uxiliary switch larm switch Shunt trip Undervoltage trip Direct rotary handle Extended rotary handle Terminal shield Insulation barrier Rear connection Pad handle lock Plugin device WHD (3P) NType HType NType BS32c BN52c BS52c BH52c BN2c BS2c BS33c BN53c BS53c BH53c BN3c BS3c BS34c BN54c BS54c BH54c BN4c BS4c (3, 5, 10) 15, 20, 30, 15, 20, 30, 40, 50 15, 20, 30 40, 50 15, 20, 30, 40, 50, (10) (14) (25) fixed fixed fixed fixed fixed fixed
2 NType HType NType HType BN102c BS102c BH102c BN202c BS202c BH202c BN103c BS103c BH103c BN203c BS203c BH203c BN104c BS104c BH104c BN204c BS204c BH204c 15, 20, 30, 40, 50, 0, 75, , 20, 30, 40, 50, 0, 75, 100, , 125, 150, 175, 200, 225, fixed fixed fixed fixed fixed fixed mb. Temp. 5 C 0 C 10 C 20 C 25 C 30 C 35 C 40 C 45 C 50 C Calibrated for 40 C In=15 to % 111.3% 110.0% 108.0% 10.% 104.9% 102.7% 100.0% 9.8% 93.3% In=40 to % 109.8% 108.7% 107.0% 105.8% 104.3% 102.4% 100.0% 97.2% 94.0% In=100 to % 113.2% 110.% 107.5% 105.8% 104.0% 102.0% 100.0% 97.9% 95.% In=250 to % 109.0% 107.0% 105.0% 104.0% 103.0% 101.5% 100.0% 98.5% 97.0% 29
3 Molded case circuit breakers Metasol 400F to 1200F Series Type Type and Pole Rated current, In Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Frame Size(F) Rated shortcircuit breaking capacity(icu) k (Sym), KSC8321, IEC C DC Service breaking capacity(%icu), Ics Category of use Endurance (Number of operations) Type of trip unit release Hydraulicmagnetic release Note) 1. applicable or available 2. available as a separate breaker C(V) DC(V) V kv 90V 480/500V 415/40V 380V 220/250V 500V(3P) 250V(2P) Mechanical Electrical Magnetic release only without thermal trip Earth leakage protection ccessories Electrical auxiliaries External accessories Dimensions (mm) Weight(kg) for uxiliary switch larm switch Shunt trip Undervoltage trip Direct rotary handle Extended rotary handle Terminal shield Insulation barrier Rear connection Mechanical interlock Plugin device WHD (3P) NType HType LType BN402c BS402c BH402c BL402c BN403c BS403c BH403c BL403c BN404c BS404c BH404c BL404c 250, 300, 350, fixed fixed fixed fixed
4 NType LType LType LType BN802c BS802c BL802c BN803c BS803c BL803c BS1003b BL1003b BS1203b BS1203bE BL1203b BN804c BS804c BL804c BS1004b BL1004b BS1204b BL1204b 500, 30, 700, fixed fixed fixed fixed fixed fixed fixed mb. Temp. 5 C 0 C 10 C 20 C 25 C 30 C 35 C 40 C 45 C 50 C Calibrated for 40 C In=15 to % 111.3% 110.0% 108.0% 10.% 104.9% 102.7% 100.0% 9.8% 93.3% In=40 to % 109.8% 108.7% 107.0% 105.8% 104.3% 102.4% 100.0% 97.2% 94.0% In=100 to % 113.2% 110.% 107.5% 105.8% 104.0% 102.0% 100.0% 97.9% 95.% In=250 to % 109.0% 107.0% 105.0% 104.0% 103.0% 101.5% 100.0% 98.5% 97.0% 31
5 Earth Leakage Circuit Breakers Metasol 30F to 250F Series Type Type and Pole Protective function Rated current, In Note) 1. applicable or available 2. available as a separate breaker Rated residual current, In Rated operational voltage, Ue Rated impulse withstand voltage, Uimp Residual current offtime at In Frame Size(F) pole 3pole 4pole m C(V) kv Rated shortcircuit breaking capacity (Icu) k (Sym), KSC8321, IEC C Service breaking capacity(%icu), Ics Category of use Endurance (Number of operations) Type of trip unit Overcurrent pickup Earth leakage pickup ccessories Electrical auxiliaries External accessories Dimensions (mm) Weight(kg) sec 40V 415V 220/250V Mechanical Electrical uxiliary switch larm switch Shunt trip Undervoltage trip Insulation barrier Terminal cover (Long) Terminal cover (Short) Rotary handle (Direct) Rotary handle (Direct, Key lock) Rotary handle (Extended) Rear terminal (Bar) Rear terminal (Round) Plugin kit Pad handle lock WHD (3P) EBS33c EBS34c Shortcircuit and Ground fault 15, 20, 30 30, 100/200/ sec NType EBN52c EBN53c EBS53c EBS54c Shortcircuit and Ground fault 15, 20, 30, 40, 50 30, 100/200/ sec HType EBH53c EBH54c Shortcircuit and Ground fault 15, 20, 30, 40, 50 30, 100/200/ sec NType EBN3c EBS3c EBS4c Shortcircuit and Ground fault 0 30,100/200/ sec
6 NType EBN102c EBN103c EBN104c EBS103c EBS104c HType EBH103c EBH104c NType EBN202c EBN203c EBS203c EBS204c HType EBH203c EBH204c Shortcircuit and Ground fault Shortcircuit and Ground fault Shortcircuit and Ground fault 0, 75, , 100/200/ sec 15, 20, 30, 40, 50, 0, 75, 100, ,100/200/ sec 100, 125, 150, 175, 200, 225, ,100/200/ sec
7 Earth Leakage Circuit Breakers Metasol 400F to 1200F Series Type Type and Pole Protective function Rated current, In Frame Size(F) Note) 1. applicable or available 2. available as a separate breaker Rated residual current, In Rated operational voltage, Ue Rated impulse withstand voltage, Uimp Residual current offtime at In 3pole 4pole m C(V) kv sec Rated shortcircuit breaking capacity (Icu) k (Sym), KSC8321, IEC C 415/40V Service breaking capacity(%icu), Ics Category of use Endurance (Number of operations) Type of trip unit Overcurrent pickup Earth leakage pickup ccessories Electrical auxiliaries External accessories Dimensions (mm) Weight(kg) 220/250V Mechanical Electrical uxiliary switch larm switch Shunt trip Undervoltage trip Insulation barrier Terminal cover (Long) 2, 3pole Terminal cover (Long) 4pole Rotary handle (Direct) Rotary handle (Extended) Mechanical interlock 2, 3pole Mechanical interlock 4pole Rear terminal 2pole Rear terminal 3pole Rear terminal 4pole Plugin kit WHD (3P) 400 NType HType LType EBN403c EBS403c EBH403c EBL403c EBN404c EBS404c EBH404c EBL404c Shortcircuit and Ground fault 250, 300, 350, , 100/200/500m 0.1 sec 0.1 sec 0.1 sec 0.1 sec
8 NType LType EBN803c EBS803c EBL803c Shortcircuit and Ground fault 500, 30, 700, , 100/200/500m 0.1 sec 0.1 sec 0.1 sec EBS1003b EBS1203b Shortcircuit and Ground fault /200/500m 100/200/500m 0.1 sec 0.1 sec
LSIS Electric Products MCB / MC&TOR / MMS / MCCB / ACB / FDB / SMDB / VCB
www.lsis.com LSIS Electric Products MCB / MC&TOR / MMS / MCCB / CB / FDB / SMDB / VCB 1, 2, 3 and 4 pole series up to 125F B, C and D Characteristics 2 and 4 pole series up to 100F Sensitivity up to 300m
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationDPX Magnetic only
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY
More informationDPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationDPX Electronic + earth leakage
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationMeta Solution. Low voltage circuit breakers. Technical Manual
Meta Solution Low voltage circuit breakers Technical Manual Contents A verview B Structure and operation C Product characteristics D perating conditions E Installation method A- B- C- D- E- F Accessories
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationBREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker
BREAKER Molded Case Circuit Breaker/Earth Leakage Circuit Breaker 2 BREAKER With an improved technology and agressive invesment in R&D, DAERYUK create differentiated value for each customer in order to
More informationDRX 250 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationDPX 160 Thermal magnetic and trip-free switches DPX-I 160
87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationDRX 100 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More information40, 50, 63, 125, , 125, , 100
DC MCCB (100~800AF) Susol MCCB is suitable for DC application such as Photovoltaic Circuit Breaker DC short circuit test tested by VDE Higher nominal voltage range up to 1000 VDC Rated Current : 16A~800A
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationCDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.
Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationDPX 630 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More information6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate
More informationC60H-DC C curve. Catalogue numbers
distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationCircuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63
Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationUTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB
PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L
More informationSpecification for 70mm pole pitch Air circuit breaker up to 1600 A
Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with
More informationMotor Protection Circuit Breakers
Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions
More informationThe effective choice The benefits of a product with the highest quality standards
The effective choice The benefits of a product with the highest quality standards Compact size for easy installation in small spaces and retrofitting of already existing facilities. Terminals designed
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationschneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.
K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles
More informationThermal magnetic and trip-free switches
87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/
More informationMolded Case Circuit Breaker
& The Ultimate Safety Breaker Molded Case Circuit Breaker www.terasaki.co.jp Catalogue No. 13!5E ! Safety Notice Carefully read instruction manual to ensure proper installation, connection, operation,
More informationGE Consumer & Industrial. M-PACT New Air Circuit Breaker A
GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More informationLow voltage moulded case circuit breaker EB2
Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation
More informationMetasol MC 4pole. Contactor. Overview 108 Table of specifications 110 Dimension 114. Contents
Metasol MC Contactor Overview 8 Table of specifications 1 Dimension 114 Contents Series completion More Safe, More Valuable Contactors & Overload Relays dvanced technology & Expert solution Offering economical
More informationMotor Protection Circuit Breakers 3VU13 and 3VU16
Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection
More informationF.T.M.C. F.T.M.C. Motor Operator For MCCB. MCCB Accessories. Motor Operator. Part No. Frame MOPF240 FTCF F MOPJ240 F FTCJ MOPK240 FTCK
Motor Operator For MCCB Motor Operator Ref.NO. F101105 MOPF20 F101106 MOPJ20 F101107 MOPK20 F101108 MOPLG20 F101109 MOPL20 58 TYPE RHM Rotary Handle Mechanisms 59 ROTARY HANDLE MCCB Ref.No. Rotary Handle
More informationLow Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A
Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection
More informationInstantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch
Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable
More informationLEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1
More information01 Spectra Plus - Introduction
01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from
More informationPrisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter
3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice
More informationP-SERIES VFD WITH BYPASS
P-SERIES VFD WITH BYPSS 1 40 HP (200~230 VC) 1 100 HP (380~480 VC), 3Ø Enclosed Bypass - UL Type 3R Standard Controls for Bypass & Local/Remote Operation Special Instructions: FETURES ND OPTIONS Compact
More informationMolded Case Circuit Breaker
Molded Case Circuit Breaker + + + Building + + + a better + + future + + + + We, Hyundai Heavy Industries Co., Ltd., are challenging + + + + for better + future with + continuous + investment + in R&D
More informationContactors & Overload relays
Contactors & Overload relays Metasol MC 3P 18 to 100 MC type Magnetic Contactors Frame size screws clamp terminals Number of poles Rated operational voltage, Ue Rated insulation voltage, Ui Rated frequency
More informationCircuit protection and control devices 0.5 to 6300 A
Electrical distribution Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2009 m TOOLS schneider-electric.com The technical guide This international site allows you to access
More informationMPW Series. MPW Catalog Number Sequence. Standard Features MPW U004
Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,
More information(p. 47) (p. 155) (p. 155)
0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic
More informationGE Consumer & Industrial Power Protection. Record SL. Moulded Case Circuit Breakers Standard Line. GE Imagination at work
GE Consumer & Industrial Power Protection Moulded Case Circuit Breakers Standard Line GE Imagination at work The new GE Molded Case Circuit Breaker family is a line of reliable, simple and easy to use
More informationNB1 Miniature Circuit Breaker
P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide
More informationMS25, MST25, MS20, MST20
Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers
More informationic60a circuit breakers (curve C)
(curve ) DB9 DB98 DB99 DB88 IE/EN 097- IE/EN 0898- ountry approval pictograms PB09-0 PB09-0 bb are multi-standard circuit breakers which combine the following functions: vvcircuit protection against short-circuit
More informationCircuit breakers. Panorama. PB111746_30.eps PB111749_30.eps
Protection Circuit breakers Panorama PB76_0.eps PB79_0.eps PB75_0.eps PB75_0.eps PB757_0.eps PB758_0.eps Circuit breakers C60 N0 Performance Number of poles P P P P P + N P + N Width (module 9 mm) 6 8
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationMulti 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com
Multi 9 TM Catalogue 207 Multistandard protection for OEM schneider-electric.com Green Premium TM Endorsing industry eco-friendly products Schneider Electric s Green Premium ecolabel is committed to offering
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationLow breaking capacity moulded case circuit breakers
New series EB2S of MCCBs has excellent performances with reduced dimensions and new modern design. Advantages of low breaking capacity MCCBs Unique accessory cover opens with only one screw. Practical
More informationSACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A
SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A Quality For You. How simple and functional can a range of moulded-case circuit-breakers be? It was answering this question, which
More informationMCCB Accessories to suit AF
MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationManual Motor Starters
Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More informationCharacteristics of LV circuit breakers Releases, tripping curves, and limitation
Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationLV & MV Circuit Breakers, Contactors & Overload Relays
LV & MV Circuit Breakers, Contactors & Overload Relays Globalization of Technology HG-Series, has been an upgraded to better performance and great customer experience. A new premium line of modern low
More informationSIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function
The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole
More information- Moulded-case Circuit Breaker
Safety Protection Catalogue 2013/2014 - MAXTRIC circuit breaker Working with the world s electric specialist together @ Cat. No. CM1 1. Application CM1 series moulded case circuit breaker is one of products
More informationCircuit Breakers Ex9M
Circuit Breakers Ex9M Moulded Case Circuit Breakers Frame size M1 with rated current up to 125 A Frame size M2 with rated current up to 250 A 3-pole versions Rated ultimate short circuit breaking capacity
More information18-I73E CAT REF.
& www.terasaki.co.jp 1-I73E CAT REF. TABLE OF CONTENTS General 1-1 Introduction 1- General 1-3 Selection Chart 1- Ratings and Specifications -1 Air Circuit Breakers for DC350V-00V - Moulded Case Circuit
More informationCompact NR630. NR100F to NR630F
Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationAPPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications
Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection
More informationBreakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary
Breakers and Switches Tmax XT Moulded-case circuit-breakers Simply extraordinary Tmax XT Simply extraordinary ABB is proud to present you the result of a long and intense research and development project:
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationNew DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE
New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with
More informationInnovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20E
Innovators in Protection Technology TemBreak Total Protection, Complete Control Catalogue No. 05 - I0E Terasaki (Europe) Ltd Terasaki Europe Ltd was established in 97 and is located near Glasgow, Scotland
More informationProduct Line Overview. The Most Logically Designed Contact Assembly
Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased
More information15-I73E CAT REF.
& www.terasaki.co.jp 5-I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers
More informationand other modular devices for low voltage installation
Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories
More informationNDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.
Shanghai Liangxin Electrical CO., LTD. - Liangxin Electrical - All rights reserved Address: No. 66 eng An Road, Pu Dong New District, Shanghai Post code: 07 Tel: 6--479 Fax: 6--5675966 E-mail: client@sh-liangxin.com
More informationEKM1-63S MCB Mini Circuit Breaker
EKM1-63S MCB Mini Circuit Breaker Standard: IEC60898-1 Rated current In :1,,3,4,6,10,13,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz
More informationElectronic circuit breaker EBU10-T
Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions
More information14-I73E CAT REF.
& www.terasaki.co.jp -I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers
More informationOSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage
Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :
More informationC60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V
DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used
More informationatalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:
atalog Welcome to.com! Contact us... Email: sales@ato.com Tel: +1 800-585-1519 (Toll-free) Website: ZMQ2E Series Dual Power Automatic Transfer Switch (ATS) Applications ZMQ2E dual auto transfer switch
More informationManual Motor Protectors
88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)
More informationLOAD BREAK SWITCHES & SWITCH FUSES
LOD BREK SWITCHES & SWITCH FUSES Switch Fuses FSF FSF 250 FSF FSF 60 Load Break Switches FLS FLS 250 FLS FLS 60 CONTENTS General Information bout Load Break Switches & Switch Fuses Technical Characteristic
More informationSACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.
SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A. New SACE Tmax XT. Simply XTraordinary. ABB SACE is proud to present you the result of a long and intense research and development
More information