1 ACB/ATS Air Circuit Breaker / Automatic Transfer Switch

2 ACB/ATS Air Circuit Breaker / Automatic Transfer Switch CREATING VALUE

3 02_03 No matter where you are in the world or in which industrial field, Daeryuk provides Total Solutions in order to deliver stable power for our customers. In order to provide stable power and protection control, Daeryuk has provided all the best solutions demanded by our customers in the past and will continue to do so in the future. We provide Total Solutions to wherever power is needed, from power stations, largescale plants, factories, and subways to residential houses, offices, and department stores. Contents Air Circuit Breaker Automatic Transfer Switch 04 32

4 Air Circuit Breaker It is the next generation type of ACB which applying highprecision Digital overcurrent relay to improve the reliability of performance It can be checked visually the load, current and upset condition through the Digital type for overcurrent relays. It considered convenience of use by facilitating the selftest. (OCR Tester purchased separately)

5 04_05 Safety is a key challenge and philosophy of technology of Daeryuk. ACB was designed conveniently and safely for users through securing various protections, safety and improving the reliability of performance Safety & Reliability Customer safety first! Safety and convenience for user IEC KS C 4620 The Cradle can be used by a safety shutter (Available to use without safety shutter). OCR(Overcurrent Relay) improved new cuttingedge functions. Improved quality through applying various attachment Overcurrent Relay Geared Motor Closing Trip (SHT, UVT) Auxcontact Trip contact Contact of open and close Spring charge contact Manual reset button Best service and technical support Useful protection system Ensure safe and quick installation Continuous guarantee service Warranty 2 years Ordering Information DRAS 06 3 F 2 S K Dae Ryuk Air Circuit Breaker Smart Sign Frame Size Sign Size 630AF 800AF 1000AF 1250AF 1600AF 2000AF Size 2500AF 3200AF 4000AF 5000AF 6300AF Number of poles Type Operating Voltage Sign Configuration Sign Type W(3P) 34W(4P) F D Fixed type Drawout type Sign Voltage(V) DC110 AC220 AC110 Sign S H Type Type Standard High breaking capacity K KS certificate

6 Appearance and Structure Appearance Description On(I) Off(O) Charged Charging Handle Closing PushButton Opening PushButton Main Contact Position(ON/) Stored Energy Mechanism Status Indicator Label Padlocking Facilities for Connected& Disconnected Position Functional Position Operation, Test, Disconnection Manual Handle Arc Chute Cover

7 06_07 Air Circuit Breaker / Automatic Transfer Switch 4P Drawout Type Cradle Economical Type Circuit Breakers It is used for TieLine when installed. Drawout & Fixed Circuit Breakers The Drawout & Fixed Breakers are derived from the same structure. Drawout Type Breaker can be changed to Fixed Type Breaker by adding a fixing bracket on each side. No other modification would not be required. Economical Type w/3p New Released Drawout Circuit Breaker Design Arc Space For the Drawout Type, Arc Space is not required if Arc Chute Cover has been applied. New Released Drawout Circuit Breaker Design Increased Safety in Test& DisconnectedPositions, all manufactures are very safe. Increased safety in Test& Disconnectedpositions. Connected Position Test Position Isolating Distance Disconnected Position Easy Disconnection w/short Travel Fully withdrawn Position Small Space requirement

8 Appearance and Structure Structure Auxiliary Devices Main Body Arc Chute OCR Controller Shunt Trip Release Coil Auxiliary Switch Charging Motor for Stored Energy Mechanism Cradle Cradle Cradle Auxiliaries Terminal Block Safety Shutter Cradle

9 08_09 Air Circuit Breaker / Automatic Transfer Switch Shunt Trip Release Coil Safety & Reliability Simple Maintenance & Repair Improved Safety with Double Insulations Simple Installation of Auxiliary Devices It is secure with only one screw to insert the Trip Devices Stored Energy Operating Mechanism DACO Circuit Breakers are designed as the methods of operating by Stored Energy mechanism is assured instantaneous opening & Closing. It's available for manually handling operation or motor operated charging mechanism. Charging Motor for Stored Energy Mechanism Common Auxiliaries for the entire range All accessories are interchangeable according to standardization of manufactures. It is secure with one screw. It is interconvertible It is secure with only one screw to insert the Geared Motor into Circuit Breaker. Label Type No. Control Voltage In (breaking capacity) Uimp (rated impulse voltage) Ui (rated insulation voltage) Ics=100% Icu Ue (rated voltage) Icu (rated breaking current) Icw (short time withstand current) UVT Standard Serial No.

10 Specification S,H Type Type Frame size (AF) Note 1) Rated current (In max) Rated voltage (Ue) Rated insulation voltage (Ui) Frequency (Hz) No. of Pole Neutral line Rated breaking current (Icu) (Sym) Ics Icm(Peak) Icw Uimp Operating time (t) Mechanical Electrical Main contact Type Dimension WDH(mm) Weight (kg) Standard Note 1). In Max. [40] IEC IEC KS C 4620 IEC KS C sec. 3 sec. breaking time closing time Maintenance Model Without Maintenance Maintenance Without Maintenance Drawout type Fixed type Drawout type Drawout type Fixed type Fixed type Drawout type Drawout type Fixed type Fixed type (%In) IEC AC AC 660V/600V/550V 500V/480V/460V 415V/380V/230V/220V 690V/600V/550V 500V/480V/460V 415V/380V/230V/220V (A) (V) (V) (P) (A) (ka) (ka) (ka) (% Icu) (ka) (ka) (ka) (ka) (ka) (kv) (ms) (ms) (No.) (No.) (No.) (No.) 3P 4P 3P 4P 3P 4P 3P 4P S DRAS06 630(A) /60 3/ Rear H S H S H S DRAS08 800(A) /60 3/ Rear kV 40ms 60ms DRAS (A) /60 3/ Rear DRAS (A) /60 3/ Rear H

11 Air Circuit Breaker / Automatic Transfer Switch 12kV 40ms 60ms 12kV 50ms 60ms 10_ Rear DRAS (A) /60 3/ H Rear DRAS (A) /60 3/ S H Rear DRAS (A) /60 3/ S H Rear DRAS (A) /60 3/ S H Rear DRAS (A) /60 3/ S H Rear DRAS (A) /60 3/ S H Rear DRAS (A) /60 3/ S H S

12 I I Dimension Fixed type [ Unit:mm ] S,H Type 630~1600 [3P] S630~2000 O ON S,HType 630~1600[4P] S630~2000 O ON

13 I I 12_13 Air Circuit Breaker / Automatic Transfer Switch Drawout type [ Unit:mm ] S,HType 630~1600[3P] S630~2000 O ON S,HType 630~1600 [4P] S630~2000 O ON

14 connected test disconnected O I ON connected test disconnected connected test disconnected O O I ON I ON connected test disconnected O I ON Dimension Drawout type S,HType 2000~2500[3P] [ Unit:mm ] S,HType 2000~2500[4P] S,HType 3200 [3P] S,HType 3200 [4P]

15 O I ON O O I ON I ON O I ON 14_15 Air Circuit Breaker / Automatic Transfer Switch Fixed type S,HType 2000~2500[3P] [ Unit:mm ] S,H Type 2000~2500[4P] S,HType 3200[3P] S,HType 3200[4P]

16 connected test disconnected O I ON Dimension Drawout type S,H Type 4000[3P] [ Unit:mm ] S,HType 4000[4P]

17 O I ON 16_17 Air Circuit Breaker / Automatic Transfer Switch Fixed type S,H Type 4000[3P] [ Unit:mm ] S,HType 4000[4P]

18 O O I ON I ON Dimension / Problem Solution Drawout type S,HType 5000[3P] [ Unit:mm ] S,HType 5000[4P] S,H Type 6000(4P)

19 18_19 Air Circuit Breaker / Automatic Transfer Switch Fixed type S,HType 5000[3P] [ Unit:mm ] S,HType 5000[4P] Trouble Shooting Trip (lamp on) Trip (lamp off) Condition Expected Causes Countermeasure Uncontrolled local trip Uncontrolled remote trip Unable to recharge machine Unable to operate the drawout breaker handle Unable to drawout the breaker Ir lamp on (Overcurrent blocking) Im lamp on (Short Time Circuit blocking) Undervoltage release action Undervoltage or UVT trouble Applied wrong voltage in SHT Release Terminal Open button locked Trip by short circuit Unable to reset the fault indicator lamp Applied undervoltage in the operation motor Checked the keylock The breaker installed inferiority on the drawout rail Inserted condition of Drawout handle The breaker disconnected inferiority Reclose the breaker Check the breaker and inspect cause before reclosing Check and resupply voltage Remove the cause (undervoltage, etc.) Inspect cause of Release Remove the cause of lock Remove the cause Reclose after checking breaker Push the reset button Apply rated voltage Firstly check the motor by manual operation If the problem persists, contact us Replace motor Unlock the keylock Please push the breaker to the end Reinsert the drawout handle Release the breaker completely

20 Digital Trip Relay OCR Control Unit Display Fault Indicator LEDs Overload, Short Circuit, Earth Fault, Instantaneous Operation Key : System Setting & Calibration Operation Reset Button Power LED Alarm Indicator Select Switch for Ct Ratio Select Switch for Long Time Overload Setting Select Switch for Long Time Delay Select Switch for Short Time Circuit Select Switch for Short Time Delay Select Switch for Instantaneous Overload Setting Select Switch for UVT Time Delay (Optional) Select Switch for Earth Protection Current Pickup Setting (Optional) Select Switch for Earth Protection Time Delay (Optional) Hz Date No. 7~15 Indication A sensing tap of changing frequency (It will be tripped after the setting time, if the frequency changed 5Hz.) Main functions Control Unit Functions OCR 1 Overload Long Time (Tr,Ir) ShortCircuit Short Time (Ir,Im) Protection Instantaneous (In) Earth Fault (Ih, Th) Reset Button for Reclosing Ammeter w/indicators & Selection Switch Fault Trip Indicators & Reset Button Overrun Alarm Indicator UVT Time Delay Selector Voltage w/ Indicators & Selection Switch * Available, Unavailable, Option OCR 2

21 20_21 Air Circuit Breaker / Automatic Transfer Switch Function Basic Functions Optional Functions Fault Trip Indicators & Reset Button Overrun Alarm Indicator Voltage UVT Time Delay Selector LED Indicating by Trip cause out of LED Flashes when the set value of w/ Indicator Delayed Tripping by Undervoltage Release Ir, Im, Ih Trip Pushed the button to Reset. External power supply NOT required. Long Time Current, Ir / overruns the value of short time current, Im External power supply NOT required Digitally displayed (DJ002) Accuracy 10% DJ001, DJ ~3 Set of (8 Steps) Trip Long Time Trip Short Time Trip INST Trip Earth Trip Setting(A)Ir=Io x Tr(at 1.5Ir) Accuracy Setting(A)Im=Ir x Tm (s) Accuracy Setting(A)Inst=In x Accuracy Setting(A)Ih=In x Tm (s) Accuracy 0.8~1.0, Off 15, 30, 60~480 10% 1,5,2,3~10,Off 0.1, % 2~22, Off 10% 0.1~0.8 Off 0.1, 0.2, 0.3, % 8 Step 6 Step 8 Step 2 Step 8 Step 8 Step 4 Step Operating Zone Basic Functions: Long Time (LT) / Short Time (ST) / Instantaneous (INST)

22 Characteristic Curve OCR SHT In : CT rated current Ir : Setting current of Long Time Delay Im : Setting current of Short Time Delay

23 22_23 Air Circuit Breaker / Automatic Transfer Switch OCRINST t(s) x In

24 Characteristic Curve OCR EarthFaultTrip In : CT rated current Ir : Setting current of Long Time Delay : Setting time of Earth Fault Trip

25 24_25 Air Circuit Breaker / Automatic Transfer Switch Circuit Diagram RST N P1 S1 P2 S T1 T D4 C12 C2 A4 B4 GE OCGR OCR CC SHT UVT SHT OB OB OA OA OC OC OC OC CT Processor Unit (F) MS CD Ammeter F11 F D1 C11 C1 A1 B1 Main Circuit Position Contact Control Power Supply(1) Fault Signal Aux. Contacts Aux. Contacts UVT Sequence Power is not applied. Symbol Contents CP Connected Position Contact (Optional) CD Disconnected Position Contact M Geared Motor Power (B1, B4) CC Closing Release (A1, A4) SHT Open Release(C1, C2) Shunt Release GE Earth Fault Protection (Optional) UVT Instantaneous Undervoltage Release (Optional) OC Auxiliary Common Contacts OA Auxiliary Normal Open Contacts (Optional) OB Auxiliary Normal Close Contacts (Optional) FI Fault Trip Indication Contact MS Charging Motor Limit Switch Contact (Optional) UVT AC220V: D1, D4 (Prevent closing of zero voltage) UVT AC220V: F11, F12 (Trip on the undervoltage and zero voltage) Fault Indicator Lamp : F11, F12 (AC220V or AC110V) Standard AC220V

26 Installation Coupling (main body and cradle) Please, put 'disconnected' position by turning lever to the left side. This 'disconnection' position prevents the extraction of the right handside rail. Then, pull the handgrip to drawout the circuit breaker. Please, put circuit breaker at the right position to match 4 supports to rail home on both parties. On the circuit breaker, push the green button to make the circuit breaker 'Open' automatically during connection. Please, do not press hard on the OCR Control Unit during installation. Push the Circuit Breaker into the cradle. In connected position, main and auxiliary circuits are connected for energizing.

27 26_27 Air Circuit Breaker / Automatic Transfer Switch Separation Open the breaker. Otherwise, it will open automatically during disconnection. If the breaker is in charge, please close the breaker first by clicking 'ON' button. Then, push '' button and open it. CAUTION: for Drawout Breaker w/fixed connection, please disconnect them first.

28 Indication ON ON The figures show the status of indication at the different positions. Recharge ON Charge the handle 7~8 times with full stokes until charging indicator shows Charged Automatically charged after each closing by Electrical Operating Mechanism Indicator States : ON or show the charging status

29 28_29 Air Circuit Breaker / Automatic Transfer Switch Electrical closing The Closing Relay operates at 85%~110% of the Rated Voltage. The closing spring of circuit breaker is automatically charged by external power source. Otherwise, charge is manually. NOTE: The breaker can be close only if it is open, charged and no tripping are simultaneously ordered. The CC withstands a continuous power supply, providing antipumping function. If the breaker is not ready to close when the closing order is intended. wired in series with the ready to close contact C, a closing order can be transmitted only if the breaker is ready to close. (Inhibition of the antipumping function) Please, press the push ON button Electrical trip The Shunt Trip operates at 85% of the Rated Voltage. Or an Undervoltage release UVT or delayed undervoltage release UVR. (Tripping between 0.35 to 0.7 Un) (for the UVR, delay adjustable to 0.5~3 seconds, front cover removed) Please, press the push button

30 Main function Main function Malfunctions Probable Causes Corrective Actions Circuit Breaker Trip (Indication by Fault Trip Indicator Lamp) Overload Trip(Fault Ir Indication Lit) Short Circuit Trip (Fault Im Indication Lit) Reclose the breaker Check breaker condition before putting back into operation Circuit Breaker Trip (NOT Indicated by Fault Trip Indicator Lamp) It may be cause of Undervoltage Release. (Instantaneous:UVT Delayed:UVT) Supplement of low or zero voltage, or UVT release may be out of service Check the voltage & Reestablish it Replace the Fault Release Voltage may spuriously input at SHT Release Terminal. Check the causes of Release order. Trip is NOT locally operating The circuit breaker is NOT remotely or locally closed. The Circuit Breaker is NOT charging properly. Open Pushbutton may be locked. Circuit Breaker may close on short circuit Fault Trip Indicator Button may NOT reset. Low voltage of Geared Motor Power Supply Remove the locking. Remove it Check circuit breaker condition before putting back into operation. Reset Fault Trip Indicator Button Apply a voltage Check the Geared Motor Electrical Circuit attempt to recharge manually Please, contact to Daeryuk Technical Support for the problem Please, change the Geared Motor It is NOT possible to insert the racking handle to connect or disconnect the circuit breakers. It is NOT possible to drawout the right side rails (on chassis alone)or the breaker It may be cause of the key interlock system. The extraction rails or the breaker may NOT be completely installed. The racking handle is remained inserted. The breaker may NOT completely disconnected. Please, release the key lock. Push the rails or the breaker all the way down. Push the rails or the breaker completely Please, disconnect the breaker *Maintenance Period: 1 time/mth.

31 30_31 Air Circuit Breaker / Automatic Transfer Switch Auxiliary Devices Position contact and Cradle contact Connecting position contact (CP) 4 C contacts indicate connection state of the breaker. Disconnecting position contact (CD) It is comprised of 2 C contacts and indicates opening condition. It can be indicated the test position, if CP contact and CD contact are connected in series. Range of switch position Motor AC 110V AC 220V DC 110V 15A 10A 1A Motor Please use a manual operation handle to be charged in emergency situation. "Stored Energy Spring" makes fast action of OCO when the breaker recharged. Remote control The breaker needs following equipments for remote control. Gear Motor (MCG) Closing Relay (CC) Shunt Relay (SHT) Electric charging and electrical closing can be operated at 85%~110% of the Rated Voltage. Range of switch position Voltage Power Supply Current Motor Start Up Current Charging Time Auxiliary switch (OC) AC 50/60 Hz 110V 220V DC 2A 1A 2A 2 to 3 x In for 0.1 sec. 3 to 4 sec. 110V Standard contacts are comprised of 4 C contacts and it can instruct open and close state of the breaker. Drawout prevention device Main spindle Closing contact Closing contact appears the following conditions Trip status of the breaker Charging status of closing operation mechanism It indicates the trip button is unlocked It is connected closing coil in series and determines whether the breaker is closing. Spring charging contact (MS) It is standard contact and indicates the spring charging state. Trip state contact (Fl) Motor Charge completion contact Gear It is standard contact and indicates the trip state.

32 Automatic Transfer Switch To provide a fast, transparent, stable power supply, Daeryuk goes one step ahead in durability and reliability with upgraded technology and performance on a different plane. TType MType

33 32_33 As a provider of optimum solutions in diverse customer environments, Daeryuk has come up with a compact set of designs to secure space and safety even in narrow areas from highrise buildings and officeresidential complexes, to general offices and industrial buildings, in a spirit of innovation. Safety & Compact New innovative and compact space! Feel the convenience of innovative compact designs. Handling and installation are made easy with light and compact designs. Minimalist switch board with light and compact designs. Enhanced safety and reliability for our customer. Main contact protection and breaking capacity have been reinforced during the design stage with the advanced closing and later trip system of auxiliary contact. Useful life of products and competitiveness are ensured through improved opening and closing functions with minimum occurrence of arcs. Quality superiority is ensured through standardization of all products. Maximum user convenience. Safety and user convenience are maximized with an automatic centralmoving system Inspection and repair are made easy with onecoil, oneoperating contact, and one extinguishing chamber. Product standardization makes use and repair easy.

34 Ratings & ATS Auto Changer Ordering Code DR M Dae Ryuk M T TB Type MType TType TBType Rating DRM 400A 600A 800A 1000A 1200A 1600A 2000A 2500A DRT 100A 200A 400A DRTB 400A No. of Pole 2 2P 3 3P 4 4P MTYPE Rated Specifications Model Rated voltage Rated current No. of pole Connection mode Short time current (1 sec) Short circuit peak current Switching capability Operating time Operating current Weight Opening Switchover AC110 AC220 DC110 Back V A P Back ka ka Class ms ms A A A kg DRM040/060 DRM080 DRM100 DRM120 DRM160 DRM200 AC 600V, DC 125V 400/ AC3, DC AC3, DC1 AC3, DC1 AC3, DC1 AC3,DC1 AC3, DC Rated Specifications(400AF) TTYPE Model DRT010 DRT020 DRT040 Rated voltage Rated current No. of pole V A P AC 600V, DC 125V Connection mode Front Back Short time current (1 sec) Short circuit peak current Switching capability ka ka Class AC3, DC AC3, DC AC3, DC1 Operating Opening ms time ms Operating current Weight Switchover AC110 AC220 DC110 Front Back A A A kg kg

35 34_35 Air Circuit Breaker / Automatic Transfer Switch ATS AUTO Changer No. Name MANUAL SELECT TIMER TIMER LAMP POWER ATS POSITION MANUAL AUTO ATS POSITION POWER TIMER LAMP TIMER MANUAL SELECT AUTO/MANUAL Function and Characteristics Switch that is used to switch ATS to Normal while operating in Manual Mode. Timer that is used to set the transfer time when switching to Normal in Auto Mode if power on Normal is restored while using power on Emergency. Lamp that blinks when transfer (Emergency Normal) time is complete. It signifies that the Timer completed its job when the transfer time is set in Auto Mode if power on Normal is restored while using power on Emergency. Lamp that signifies power on Normal. Lamp that signifies ATS is currently transferred to Normal. Lamp that signifies ATS is currently set on Manual Mode. When blinking, it is controlled by the Manual Select Switch. Lamp that signifies ATS is currently set on Auto Mode. When blinking, it is automatically transferred if the set time elapses while power on Normal is cut off or restored. Lamp that signifies ATS is currently transferred to Emergency. Lamp that signifies power on Emergency. Lamp that blinks when transfer (Normal Emergency) time is complete. It signifies that the Timer completed its job when the transfer time is set in Auto Mode if power is cut off by KEPCO (Korea Electric Power Corp). VOLUME that is used to set a transfer time when switching to Emergency in Auto Mode if power on Normal is cut off. Time can be set up to 30 seconds. Switch that is used to transfer ATS to Emergency in Manual Mode. Switch that is used to set ATS transfer mode. Internal Circuit 136 [ Unit:mm ] ATS T/TNType Emergency B2 Ba Ba B1 A1 Aa Aa A2 Normal 122 ATS AUTO CHANGER B1 B2 Ba Ba B1 C2 C1 A1 Aa Aa A2 A ATS MType B1 B2 Ba Ba B1 C2 C1 A1 Aa Aa A2 A1 ATS Auto Changer symbols, A1 and A2 are KPower (normal power) whereas B1 and B2 are emergency power. Aa and Ba represent Aux. terminals.

36 MTYPE External Dimension Circuit Diagrams for Internal Control(AC.DC) Internal Circuit Operation Power AC Operation Power DC A1 B1 A1 B1 C1 C2 Aa Ba P C0 C1 C2 Aa Ba CC : Closing Coil R1 : Operating relay on A 1 R1 R2 : Operating relay on B Aux Aux R1 Ab Bb R2 A1 : Operating power on A 3 2 D 6 R1 R2 A2 : Operating power on A B1 : Operating power on B 4 D R1 Nc L/S No AuxB B2 : Operating power on B CC COM CC C1 : Input signal on A power Aux 5 R1 R2 Ba C2 : Input signal on B power R2 D : Diode 6 Aux Aa R1 R2 Aux : Auxswitch R2 4 8 AuxA : Auxswitch A 8 AuxA AuxB : Auxswitch B N Aa Ba A2 B2 Aa Ba Aa : a contact on AuxA Ba : a contact on AuxB Power Relay A1 : A1 Auxterminal Power Relay Contact R1 R2 B1 : B1 Auxterminal Contact R1 R P : DC operation power N : DC operation power L/S : Limit switch *COM : L/S COMMON TERMINAL *NC : L/S Normal Closed *NC : L/S Normal Open (Aux)Aa : AuxA a contact (Aux)Ba : AuxB a contact (Aux)Ab : AuxA b contact (Aux)Bb : AuxB b contact C0 : P auxiliary terminal Circuit Diagrams for External Control(AC.DC) Operating Power AC 27Ta AUTO 84Ta AUTO MANU 27Xa MANU 84Xa Aa Ba If you configure a circuit in reference to circuit diagrams, you can minimize the ATS failure rate. Operating power on A Operating power on B 27Xb 27Tb 27X 27T 84X 84T A1 C/S C1 A1 B1 B1 C2 A2 ATSM B2 C/S L Aux(ATS) L 27T : 27X operation signal delay relay 27X : Operation relay on A power 84T : 84X operation signal delay relay 84X : Operation relay on B power C/S : Manual operation switch AUTO : Auto mode selection switch MANU : Manual mode selection switch Operating Power DC Aa Ba 27Ta AUTO 84Ta AUTO MANU 27Xa MANU 84Xa Aux(ATS) Operating power on A Operating power on B 27Xb 27Tb C/S C/S 27X 27T 84X 84T P C0 C1 ATSM N C2 L L DCPOWER P : DC(+) Power Terminal N : DC() Power Terminal Safety Caution Caution Use a 2.0 or thicker power line for models below ATS 2500A, and use a 3.5 or thicker power line for model 2500A or above. For manual operation, operate the selection switch manually before using manual handle. If you make a transfer move with the power still on, it can cause an accident. Be sure to turn off the power before you make a transfer move.

37 36_37 Air Circuit Breaker / Automatic Transfer Switch Parts Name Exterior Dimension Busbar Dimension 3P DRM040~DRM200 [ Unit:mm ] 1 H Arc space 150 Operation circuit terminal block Manual handle insertion hole Input indicator on A Input indicator on B Auxswitch Main circuit input terminal on A power Main circuit (output) terminal on load Main circuit input terminal on B power Available to add external contact Exterior Dimension Type DRM040 DRM060 DRM080 DRM100 DRM120 DRM160 DRM200 X1 X2 X Y1 Y Y H 240 T P [ Unit:mm ]

38 MTYPE External Dimension Parts Name Exterior Dimension Busbar Dimension 4P DRM040~DRM200 [ Unit:mm ] Y2 Y1 T1 H X1 X2 14 Y3 Y3 X3 P1 P1 P1 Arc space 150 Operation circuit terminal block Manual handle insertion hole Input indicator on A Input indicator on B Auxswitch Main circuit input terminal on A power Main circuit (output) terminal on load Main circuit input terminal on B power

39 38_39 Air Circuit Breaker / Automatic Transfer Switch Exterior Dimension Type DRM040 DRM060 DRM080 DRM100 DRM120 DRM160 DRM200 X1 X2 X3 Y1 Y2 Y3 H T P [ Unit:mm ] Busbar dimension Type W1 W2 W3 L T [ Unit:mm ] [ Unit:mm ] 1 Y L L L W1 W2 W3 T2

40 T/ TBType External Dimension [ Unit:mm ] Exterior Dimension X1 X2 A W1 W1 W1 W1 12 Y5 Y4 Y3 Y2 R S T N Y1 X3 X4 X4 X4 T1 TF TB A/B condition indicators Manual handle insert hole Operating circuit terminal block Input terminal on A Input terminal on B Load terminal [Output] Available to add external contact Exterior Dimension(TType) X1 X2 Type X3 X4 Y1 Y2 Y3 Y4 Y5 W1 T1 A 2P 3P 4P 2P 3P 4P [ Unit:mm ] 9 11

41 40_41 Air Circuit Breaker / Automatic Transfer Switch Exterior Dimension [ Unit:mm ] A X3 W1 W1 W1 W1 X4 X4 X4 X2 X1 12 Y2 Y TB T A/B condition indicators Manual handle insert hole Operating circuit terminal block Input terminal on A Load terminal [Output] Input terminal on B Exterior Dimension(TBType) X1 X2 Type X3 X4 Y1 Y2 W1 T1 A 3P 4P 3P 4P 400A [ Unit:mm ]

42 T/ TBType Schematic Diagram Internal Control Circuit Diagram Internal Circuit A1 Aa B1 Ba Bb Ab AuxCb AuxAa AuxDb AuxBa AuxBb AuxAb C1 C2 A2 Aa B2 Ba Bb Ab Auxswitch AuxA AuxB AuxC AuxD (Aux)Cb : C Auxswitch b contact (Aux)Db : C Auxswitch b contact

43 42_43 Air Circuit Breaker / Automatic Transfer Switch External Control Circuit Diagram (AC, DC) Operating Power AC Aa Ba 27Ta AUTO 84Ta AUTO MANU 27Xa MANU 84Xa Aux(ATS) Operating power on A Operating power on B 27X 27T 84X 84T 27Xb 27Tb C/S C/S L L A1 A2 ATST/TB B1 B2 Operating Power DC Aa Ba 27Ta AUTO 84Ta AUTO MANU 27Xa MANU 84Xa Aux(ATS) Operating power on A Operating power on B 27X 27T 84X 84T 27Xb 27Tb C/S C/S L L DC POWER A1 A2 ATST/TB B1 B2

44 Head Office & Factory 530, Samkyeri, Pogokeup, Cheoingu, Yonginsi, Kyunggido, Korea TEL : ~3 FAX : Specifications in this catalog are subject to change without notice due to continuous product development and improvement. Copyright(c)2014 by DAERYUK CO., LTD. All Rights Reserved

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

5. OVERCURRENT RELEASE (OCR)

5. OVERCURRENT RELEASE (OCR) 5. OVERCURRENT RELEASE (OCR) Options available for the type AR ACBs include a highly reliable, multi-functional overcurrent release (OCR) with a built-in 8- bit microprocessor. This OCR is supplied with

More information

5. OVERCURRENT RELEASE (OCR)

5. OVERCURRENT RELEASE (OCR) 5. OVERCURRENT RELEASE (OCR) Options available for the type AR ACBs include a highly reliable, multi-functional overcurrent release (OCR) with a built-in 8- bit microprocessor. This OCR is supplied with

More information

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker BREAKER Molded Case Circuit Breaker/Earth Leakage Circuit Breaker 2 BREAKER With an improved technology and agressive invesment in R&D, DAERYUK create differentiated value for each customer in order to

More information

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

low voltage GLOBAL CATALOGUE RANGE ACB Air Circuit Breakers

low voltage GLOBAL CATALOGUE RANGE ACB Air Circuit Breakers CATALOGUE GLOBAL RANGE 3. ACB Air Circuit Breakers Inde 3. Air Circuit Breakers 3.1 ACB Product Overview Air Circuit Breakers 3.2-3.3 ACB Product Specifications 3.4 ACB Accessories Overview 3.5 ACB Accessory

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

Low voltage circuit breakers

Low voltage circuit breakers Super Solution North American Edition Low voltage circuit breakers Contents Overview Main characteristics Accessories Technical information Mounting & connection Characteristics curves Dimensions A-1 A-2

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times. The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.

More information

Magnum IEC Low Voltage Air Circuit Breakers

Magnum IEC Low Voltage Air Circuit Breakers Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.

More information

CONTENTS. Dimensions A1-57

CONTENTS. Dimensions A1-57 A1 CONTENTS For industrial and residential Features A1-02 External & Internal Configuration A1-04 Basic Operation/Trip Method/Standards/Certification A1-06 Features A1-08 Ratings A1-10 OC(G)R(Over Current(Ground)Relay)

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

(Example) In case of DC24 to 48V, it is operating time for DC24V.

(Example) In case of DC24 to 48V, it is operating time for DC24V. 7 9 8 Closing coil (CC) The closing coil is a device to close the breaker by remote control. An interlock to prevent pumping is provided electrically. CC circuit diagram Rated voltage (Applicable voltage

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

ACB l COMET AIR CIRCUIT BREAKER

ACB l COMET AIR CIRCUIT BREAKER ACB l COMET AIR CIRCUIT BREAKER MASCHINENBAU HALBERSTADT GROUP, building on its 60 years legacy in power generation, introduces COMET Air Circuit Breaker designed to meet the standards and the requirements

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker & The Ultimate Safety Breaker Molded Case Circuit Breaker www.terasaki.co.jp Catalogue No. 13!5E ! Safety Notice Carefully read instruction manual to ensure proper installation, connection, operation,

More information

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted 110 The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR208S AR212S AR216S AR220S AR325S AR332S AR440S AR440SB AR212H AR216H

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR650S, AR663S, AR663H Notice Be sure to read this manual before installing,

More information

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB 1 Section Contents PAGES 1. Introduction 2-5 Salient features, internal & general appearance of Drawout ACB 2. Ratings & Specifications 6-9 Free air & enclosed thermal current ratings for AC & DC applications

More information

World Super Series WSS The extensive breaker series from Mitsubishi Electric

World Super Series WSS The extensive breaker series from Mitsubishi Electric MODEL PUSH TO TRIP TEST 3 P IEC60947-2 JIS C 8201-2 Ue 690VAC 00VAC 440VAC 41VAC 400VAC 380VAC 230VAC T Ir Ip Is Ts EN60947-2 40 C Icu/Ics 8/8kA 30/30kA 8/8kA MODEL POLE Ui 690VAC 0-60Hz 8kV Uimp PUSH

More information

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits 7 Technical Data Dielectric strength Circuit Withstand voltage (at 50/60 Hz) Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control

More information

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V. Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue Low voltage Masterpact NT and NW LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type Catalogue 2015 Functions and characteristics Circuit breakers and switch-disconnectors NT06

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution Power and productivity for a better world TM Table of contents 4 1. Description 9 2. How to choose and order the circuit-breakers

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) Types: KA208S KA212S KA216S KA220S KA325S KA332S KA440S KA212H KA216H KA220H KA316H KA320H

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics:

More information

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics:

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Air Circuit Breakers DH series General information

Air Circuit Breakers DH series General information General information Air circuit breakers Description The newly designed air circuit breakers have excellent features as follows: The height and depth dimensions are identical in all sizes up to 3200AF

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS DIVISION 26 ELECTRICAL SECTION 26 28 19 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install circuit breakers in switchboards, distribution panelboards, and separate enclosures for overcurrent protection

More information

Masterpact NW DC Circuit Breakers

Masterpact NW DC Circuit Breakers Masterpact NW DC Circuit Breakers Catalog 0613CT0501R1/07 2007 Class 0613DC CONTENTS Description..............................................Page Contents General Information Line 1.........................................

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

Masterpact NW DC Circuit Breakers

Masterpact NW DC Circuit Breakers Masterpact NW DC Circuit Breakers Catalog 0613CT0501 R06/15 2015 Class 0613 CONTENTS Description............................................. Page General Information..........................................

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) Types: AR208S AR212S AR216S AR220S AR325S AR332S AR440S AR440SB AR212H AR216H AR220H AR316H

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.02 2011 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.02 2011 Contents SION Vacuum Circuit-Breakers Medium-Voltage Equipment Catalog

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary Breakers and Switches Tmax XT Moulded-case circuit-breakers Simply extraordinary Tmax XT Simply extraordinary ABB is proud to present you the result of a long and intense research and development project:

More information

Ensuring excellent switching capability and high quality with various advantages

Ensuring excellent switching capability and high quality with various advantages VCB Vacuum Circuit Breaker Ensuring excellent switching capability and high quality with various advantages Retaining the high dielectric strength with the interrupter of the high vacuum degree of 10-7

More information

ACB l COMET AIR CIRCUIT BREAKER

ACB l COMET AIR CIRCUIT BREAKER ACB l COMET AIR CIRCUIT BREAKER MASCHINENBAU HALBERSTADT GmbH, building on its 60 year legacy in power generation, introduces COMET Air Circuit Breaker designed to meet the standards and the requirements

More information

LV & MV Circuit Breakers, Contactors & Overload Relays

LV & MV Circuit Breakers, Contactors & Overload Relays LV & MV Circuit Breakers, Contactors & Overload Relays Globalization of Technology HG-Series, has been an upgraded to better performance and great customer experience. A new premium line of modern low

More information

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.0 008 Answers for energy. R-HG11-17.tif Siemens HG 11.0 008 Contents Contents Page SION Vacuum Circuit-Breakers Description General Construction

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker Molded Case Circuit Breaker + + + Building + + + a better + + future + + + + We, Hyundai Heavy Industries Co., Ltd., are challenging + + + + for better + future with + continuous + investment + in R&D

More information

Controlled Power HSN High Speed DC Circuit Breakers

Controlled Power HSN High Speed DC Circuit Breakers Controlled Power HSN High Speed DC Circuit Breakers Each CP Type HSN circuit breaker unit can consist of either a wheeled truck and housing or be panel mounted. The circuit breaker can be mounted on the

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide VersaRupter 5-38 kv Load Interrupter Switch Technical Guide NOTICE Components in this catalog are intended for use by switchgear assemblers engaged in original equipment manufacturing. All sales are subject

More information

Miniature circuit breakers. Residential current circuit breaker. Busbar systems. Comfort functions/energy control. Residential enclosures

Miniature circuit breakers. Residential current circuit breaker. Busbar systems. Comfort functions/energy control. Residential enclosures .2....6 special versions High performance range H for 000V/AC Circuit breaker for 7V/DC DC circuit breaker up to 0V/DC Miniature circuit breakers A.7.8.0 Technical data Economy range N, V/AC Standard range

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

VD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution

VD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution VD4/R Medium Voltage vacuum circuit-breakers for secondary distribution DESCRIPTION CIRCUIT-BREAKER SELECTION AND ORDERING SPECIFIC PRODUCT CHARACTERISTICS OVERALL DIMENSIONS ELECTRIC CIRCUIT DIAGRAM

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

Air Circuit Breaker Instruction Manual

Air Circuit Breaker Instruction Manual Innovators in Protection Technology Air Circuit Breaker Instruction Manual AGR-31B Overcurrent Protection Device 06-M55EC INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

The effective choice The benefits of a product with the highest quality standards

The effective choice The benefits of a product with the highest quality standards The effective choice The benefits of a product with the highest quality standards Compact size for easy installation in small spaces and retrofitting of already existing facilities. Terminals designed

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone:

More information

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/14 2014 Class 0612 CONTENTS Description............................................. Page General Information..........................................

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

Air Circuit Breaker Instruction Manual

Air Circuit Breaker Instruction Manual Innovators in Protection Technology Air Circuit Breaker Instruction Manual AGR-21B/22B Protection Relays 06-M55EB INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-21B, 22B

More information

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary US Brochure Tmax XT Molded case circuit breakers Simply XTraordinary XTraordinary benefits ABB, a global leader in circuit breaker technology is making major investments in the United States to bring extraordinary

More information

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs. SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information