1 Prime-MEC LS HRC Power Fuses

2 Current without Power Fuse (ka ms) Ipeak Let through current Below 0.5 Cycle Rated voltage(kv) Initiation of arcing(degree) Ipeak(kA) Power Factor 0.07 ~ 0.5 Test current : ka Basis : 3A I peak : Let through current(under the short circuit test)

3 Features The LS HRC Power Fuses belong to the PRIME MEC series. It interrupts high currents before the first loop of fault current has reached its natural peak value and therefore cuts down the required withstand capacity of the associated equipment on the electric system. Though small in size, it has a high breaking capacity and its enclosed type is suitable for use inside of the panel board. PRIME MEC fuses are equipped with striker pins for trip indicators as well as for operating the related load break switches. Link type fuse holder enables easy maintenance and high stability when replacing the fuses. With Fuse Checker, checking the conditions of a fuse in the panel board or by telecommunication is possible.(optional) Applied standards IEC -, DIN 35, BS 9, KSC Applications Transformer protection - To protect against short circuit current in the secondary part of a transformer and fault current in the transformer circuit. Condenser protection - To protect against fault current in the condenser circuit. Motor protection - To protect against fault current in the motor circuit Cable protection - Fault current protection secures the cable

4 LS HRC Power Fuses Ratings Type LFL-3/G-5B LFL-3/G-B LFL-3/G-B LFL-3/G-30B LFL-3/G-B LFL-3/G-50B LFL-3/G-0B LFL-3/G-75B LFL-3/G-0B LFL-3/G-5B LFL-3G-0B LFL-3G-0B LFL-G-0B LFL-G-0B LFL-G-5B LFL-G-B LFL-G-B LFL-G-B LFL-G-5B LFL-G-30B LFL-G-B LFL-G-50B LFL-G-0B LFL-G-75C LFL-G-0C LFL-G-5B LFL-G-0B LFL-G-0B Rated voltage (kv) 3./ Rated current (A) Fuse link Dimensions Weight A B (kg) Breaking current (ka, rms) 5 Minimum breaking current (A) 5In 5In In Type LFH-G-DHB LFH-G-DHB LFH-G-DHB LFH-G-DHC Fuse holder Rated voltage (kv) 7. 0 Rated current (A) Insulation level (BIL, kv) 5 Note). Application site : Indoor use. Refer to the column "B" in the table for inside diameters of Hook rings 3. Models highlighted can be applied to 3. or 7.kV 3

5 Conditions of selection Basic conditions for selecting the Power Fuses The rated current of a Power Fuse should be higher than sum of the total rated current of the electric equipment on the circuit. Back-up protection with electric equipment on the circuit. - Set the operating characteristics of the Power Fuses to satisfy the over-current characteristics of the protected loads on the circuit. Also, set the occurred calories, by the l t operation, to be smaller than the short-circuit intensity of the electric equipment and circuit. - When using the Power Fuses for backup usage with other protective equipment, set the operating times of the protective equipment below the minimum breaking current to be faster than those of the Power Fuses. For transformer protection Circuit Transformer Circuit Transformer Circuit Transformer Phase voltage capacity Applied fuses voltage capacity Applied fuses voltage capacity Applied fuses (kv) (kva) (kv) (kva) (kv) (kva) ~ LFL-3/G-5B ~ LFL-3/G-5B ~3 LFL-G-5B ~3 LFL-3/G-B 3~5 LFL-3/G-B 3~90 LFL-G-B ~0 LFL-G-B 5~3 LFL-3/G-B 30~ LFL-3/G-B 99~ LFL-G-B ~9 LFL-G-5B ~ LFL-3/G-30B ~ LFL-3/G-30B 9~3 LFL-G-30B ~ LFL-3/G-B 0~5 LFL-3/G-B 7~557 LFL-G-B ф 3.3 9~ LFL-3/G-50B. 9~ LFL-3/G-50B.9 35~79 LFL-G-50B ~37 LFL-3/G-0B 3~75 LFL-3/G-0B 30~97 LFL-G-0B 3ф 3.3 ~5 LFL-3/G-75B 3~330 LFL-3/G-75B 50~5 LFL-G-75B ~ LFL-3/G-0B 5~ LFL-3/G-0B 93~57 LFL-G-0B 5~75 LFL-3/G-5B 30~550 LFL-3/G-5B 3~90 LFL-G-5B ~35 LFL-3/G-0B 5~70 LFL-3/G-0B 5~3 LFL-G-0B 5~ LFL-3/G-0B 37~0 LFL-3/G-0B 50~3050 LFL-G-0B.7~ LFL-3/G-5B 3~ LFL-3/G-5B 3~75 LFL-G-5B ~ LFL-3/G-B ~ LFL-3/G-B 75~57 LFL-G-B ~33 LFL-G-B 5~53 LFL-3/G-B 5~7 LFL-3/G-B 7~35 LFL-G-B ~ LFL-G-5B 35~73 LFL-3/G-30B 70~5 LFL-3/G-30B 5~53 LFL-G-30B 9~3 LFL-3/G-B 37~ LFL-3/G-B ~95 LFL-G-B 5~77 LFL-3/G-50B. 70~35 LFL-3/G-50B.9 59~ LFL-G-50B ~3 LFL-3/G-0B 9~7 LFL-3/G-0B 75~55 LFL-G-0B 7~5 LFL-3/G-75B 33~57 LFL-3/G-75B 00~93 LFL-G-75B ~3 LFL-3/G-0B 3~7 LFL-3/G-0B 00~5 LFL-G-0B ~7 LFL-3/G-5B 5~95 LFL-3/G-5B 3~330 LFL-G-5B 35~ LFL-3G-0B 735~ LFL-G-0B 30~3 LFL-G-0B 59~7 LFL-3G-0B 755~5 LFL-G-0B 593~57 LFL-G-0B Selecting conditions The inrush current of a transformer is selected assuming that the current is time that of the full-load transformer current in 0.sec. The rated current of the Power Fuses is selected to continuously flow at.5time of the transformer rated current. Power Fuses for proteting against short-circuit in the secondary part of a transformer are selected assuming that the current is 5times that of the transformer rated current in seconds. Note). Models highlighted can be applied to 3. or 7.kV

6 LS HRC Power Fuses Conditions of selection For condenser protection Circuit Transformer Circuit Condenser Circuit Condenser Phase voltage capacity Applied fuses voltage capacity Applied fuses voltage capacity Applied fuses (kv) (kva) (kv) (kva) (kv) (kva) ~9. LFL-3/G-5B ~9 LFL-3/G-5B ~ LFL-G-5B 9.~ LFL-3/G-B 9~ LFL-3/G-B ~3 LFL-G-B ~7 LFL-G-B ~3 LFL-3/G-B ~ LFL-3/G-B 3~3 LFL-G-B ~7 LFL-G-5B 3~ LFL-3/G-30B ~9 LFL-3/G-30B 3~37 LFL-G-30B 3ф 3.3 ~ LFL-3/G-B. 9~ LFL-3/G-B.9 37~5 LFL-G-B Selecting conditions ~ LFL-3/G-50B ~3 LFL-3/G-50B 5~5 LFL-G-50B ~5 LFL-3/G-0B 3~ LFL-3/G-0B 5~7 LFL-G-0B 5~50 LFL-3/G-75B ~300 LFL-3/G-75B 7~ LFL-G-75B 50~ LFL-3/G-0B 300~5 LFL-3/G-0B ~55 LFL-G-0B ~75 LFL-3/G-5B 5~550 LFL-3/G-5B 55~370 LFL-G-5B 75~370 LFL-3G-0B 550~7 LFL-G-0B 370~370 LFL-G-0B 370~500 LFL-3G-0B 7~00 LFL-G-0B 370~00 LFL-G-0B The inrush current of a condenser is selected to withstand 7time of the condenser rated current in 0.00sec. The rated current of the Power Fuses is selected to continuously flow at.3 times of the condenser rated current. Note). Models highlighted can be applied to 3. or 7.kV For motor protection For cable protection Circuit Circuit Phase voltage Motor output Applied fuses voltage Motor output Applied fuses (kv) (kva) (kv) (kva) Cable diameter (mm ) Rated(A) current of PF (A) 3ф 3.3 Selecting conditions.3~7. LFL-3/G-5B.7~5 LFL-3/G-5B 7.~9 LFL-3/G-B 5~5 LFL-3/G-B 9~39 LFL-3/G-B 5~5 LFL-3/G-B 3~ LFL-3/G-30B 5~ LFL-3/G-30B ~7 LFL-3/G-B ~3 LFL-3/G-B 7~9 LFL-3/G-50B. 3~5 LFL-3/G-50B ~9 LFL-3/G-0B 9~30 LFL-3/G-0B 39~99 LFL-3/G-75B ~7 LFL-3/G-75B 5~ LFL-3/G-0B 377~0 LFL-3/G-0B 9~3 LFL-3/G-5B 7~7 LFL-3/G-5B ~7 LFL-3G-0B ~5 LFL-G-0B 93~5 LFL-3G-0B 95~50 LFL-G-0B The starting current of a motor is selected to withstand 5 times of the full-loads current in sec. Note). Models highlighted can be applied to 3. or 7.kV Under the short-circuit condition, the power fuse breaks the circuit in high speed. Therefore, with relatively high rated current, the Power Fuse protects small size cables. Selected to protect from above times of the short-circuit current. 5

7 Characteristics curves A 0A 75A 3A 50A A 30A A A 5A A 5A 0 A 0A 0 A 75A A A 3A Cut-off current (peak value:ka) Operating time (sec) A Prospective breaking current(rms : ka) Prospective rated current(rms : A) A 0A /7.kV Cut-off characteristics 3./7.kV Pre-arcing timecurrent characteristics 3.kV Cut-off characteristics 3.kV Pre-arcing timecurrent characteristics A 0A Cut-off current (peak value:ka) Operating time (sec) Prospective breaking current(rms : ka) Prospective rated current(rms : A)

8 LS HRC Power Fuses Characteristics curves kV Cut-off characteristics 7.kV Pre-arcing timecurrent characteristics A 0A Cut-off current (peak value:ka) 0A 0A Operating time (sec) Prospective breaking current(rms : ka) Prospective rated current(rms : A) kv Cut-off characteristics kv Pre-arcing timecurrent characteristics Cut-off current (peak value:ka) Operating time (sec) Prospective breaking current(rms : ka) Prospective rated current(rms : A) 7

9 Fuse holder dimensions Indoor use Power Fuse holder LFH-G-DHB Type C (Peak height in open condition) Hook Ring ф.5(hold) Fuse size(a) B C ф ф Mounting hold Earth hole Fuse checker Indoor use Power Fuse holder LFH-G-DHB Type 5.5 (Peak height in open condition) ф.5(hold) Hook Ring Mounting hole Earth hole Below Fuse checker

10 LS HRC Power Fuses Fuse holder dimensions Indoor use Power Fuse holder LFH-DHB(C) Type C (Peak height in open condition) Hook Ring ф.5(hold) Fuse size(a) B C ф ф ф (7) Note) Dimension in ( ) is for LFH-G-DHC Mounting hold Earth hole Below Fuse checker Power Fuse holder Panel Conductor Panel D: Minimum insulation distance in opening E: Minimum insulation distance in closing Rated Rated Circuit Insulation Dimensions(mm) PH Holder type voltage current voltage level Applied fuse (kv) (A) (kv) (BIL, kv) A B C D E F G LFL-3/G-5B, B, B, 30B, B, 50B LFL-3/G-0B, 75B, 0B LFH-G-DHB LFL-3/G-5B, B, B, 30B, B, 50B LFL-3/G-0B, 75B, 0B LFL-3/G-5B, LFL-3G-0B, 0B LFH-G-DHB LFL-3/G-5B, LFL-G-0B, 0B LFL-G-5B, B, B, B LFH-G-DHB LFL-G-5B, 30B, B, 50B, 0B LFL-G-75C, 0C 5B, 0B LFH-G-DHB LFL-G-0B 9

11 Striker operating characteristics & Ordering information Striker operating characteristics Operating characteristics of the Power Fuses Operating weight (kgf) The characteristics of the Power Fuses are native and fixed. Therefore it can not be regulated like a circuit breaker or over-load relay. When ordering, please select the Power Fuses with proper current and operating characteristics by considering its usage and circuit condition. Breaking a small current. Power Fuses are not adequate to protect small current. So, the manufacturer specifies and guarantees the minimum breaking current by regulation. ) Select the rated current of the Power Fuse, which does not operate below the minimum breaking current. ) Protect the current below the minimum value by use of other protective equipment. Operating distance(mm) Types of P/F Link & P/F Holder P/F Link LFL G 50 B Model name Rated voltage General use Rated current Revision No. 3/ 3./7.kV 5 5A 50 50A 3 3.kV A 0 3A 7.kV A 75 75A kv A 0 0A 5 5A 5 5A 30 30A 0 0A A 0 0A P/F Holder LFH G D H B 5 Model name General use Indoor use Revision No. B - C 0A(kV) Rated voltage Rated current 3/ 3./7.kV H 0A kv H 0A Fuse Checker 0 Without With Hook Ring

12 Safety Instructions For your safety, please read user's manual thoroughly before operating. Contact the nearest authorized service facility for examination, repair, or adjustment. Please contact a qualified service technician when you need maintenance. Do not disassemble or repair by yourself! Any maintenance and inspection shall be performed by the personnel having expertise concerned. c 03. LSIS Co.,Ltd. All rights reserved. HEAD OFFICE Korea Gyeonggi-do Anyang-si dongan-gu LS-ro 7 (Hogye-dong) Tel. (-)3-7, 73, Fax. (-)3- CHEONG-JU PLANT Cheong-Ju Plant #, Song Jung Dong, Hung Duk Ku, Cheong Ju, 3-7, Korea Specifications in this catalog are subject to change without notice due to continuous product development and improvement. Global Network LSIS (Middle East) FZE Dubai, U.A.E. Address: LOB 9 JAFZA VIEW TOWER Room 5, Jebel Ali Freezone P.O. Box, Dubai, United Arab Emirates Tel: Fax: jungyongl@lsis.biz Dalian LSIS Co., Ltd. Dalian, China Address: No.5, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 00, China Tel: Fax: lixk@lsis.com.cn LSIS (Wuxi) Co., Ltd. Wuxi, China Address: -A, National High & New Tech Industrial Development Area, Wuxi, Jiangsu,, P.R.China Tel: Fax: xuhg@lsis.com.cn LSIS-VINA Co., Ltd. Hanoi, Vietnam Address: Nguyen Khe - Dong Anh - Ha Noi - Viet Nam Tel: ---0 Fax: srjo@lsisvina.com LSIS-VINA Co., Ltd. Hochiminh, Vietnam Address: Nguyen Thi Minh Khai Str. Yoco Bldg th Floor, Hochiminh City, Vietnam Tel: Fax: sbpark@lsisvina.com LSIS Shanghai Office Shanghai, China Address: Room E-G, th Floor Huamin Empire Plaza, No.7, West Yan'an Road Shanghai 0050, P.R. China Tel: (09) Fax: jinhk@lsis.com.cn LSIS Beijing Office Beijing, China Address: B-Tower 7FL.Beijing Global Trade Center B/D. No.3, BeiSanHuanDong-Lu, DongCheng-District, Beijing 003, P.R. China Tel: ,7 Fax: cuixiaorong@lsis.com.cn LSIS Guangzhou Office Guangzhou, China Address: Room 3,F,New Poly Tower, Zhongshan Liu Road,Guangzhou, P.R. China Tel: Fax: linsz@lsis.biz LSIS Chengdu Office Chengdu, China Address: Room 70 7Floor, huanminhanjun internationnal Building, No Fuxing Road Chengdu, 0, P.R. China Tel: Fax: yangcf@lsis.com.cn LSIS Qingdao Office Qingdao, China Address: 7B,Haixin Guangchang Shenye Building B, No.9, Shandong Road Qingdao 00, P.R. China Tel: Fax: lirj@lsis.com.cn LSIS NETHERLANDS Co.Ltd Qingdao, Netherlands Address: st. Floor, Tupolevlaan, 9NZ,Schiphol-Rijk, The Netherlands Tel: Fax: junshickp@lsis.biz LSIS Gurgaon Office Gurgaon,India Address: 9 First Floor, Park Central, Sector-30, Gurgaon- 00, Haryana, India 0. 0 LS HRC Power Fuses (E) 03. 0/(03) 0. 0 Printed in Korea STAFF

LG HRC Power Fuses ISO 9001 ISO 14001

LG HRC Power Fuses ISO 9001 ISO 14001 LG HRC Power Fuses ISO 900 ISO Current without Power Fuse (ka ms) Ipeak Let through Below 0.5 Cycle voltage(kv) Initiation of 3. 7. 5.5 3 arcing(degree) Ipeak(kA) Power Factor 5 5 90 5 70 9 0 7 7 7 5 5

More information

Tri-MEC Load Break Switch

Tri-MEC Load Break Switch Leader in Electrics & Automation Tri-MEC Load Break Switch Electric Equipment Leader in the field of industrial electricity & automation creating the comfortable and productive society through providing

More information

Solution Power Medium Voltage Metal Clad Switchgear

Solution Power Medium Voltage Metal Clad Switchgear www.lsis.biz Solution Power Medium Voltage Metal Clad Switchgear Contents Features 12 Ratings 14 Structures and dimensions 16 Accessories and apparatuses 18 Arrangement (for general application) 22 2I

More information

SF6 Gas Insulated Ring Main Unit RMU. A Compact switchgear solution for secondary power distribution networks. Super Solution.

SF6 Gas Insulated Ring Main Unit RMU. A Compact switchgear solution for secondary power distribution networks. Super Solution. www.lsis.biz SF6 Gas Insulated Ring Main Unit RMU A Compact switchgear solution for secondary power distribution networks. Super Solution Ring Main Unit Ring Main Unit The best solution for Power Distribution

More information

High Torque Performance and Precise Control. 0.75~75kW 3Phase 200 ~ 230Volts 0.75~375kW 3Phase 380 ~ 480Volts

High Torque Performance and Precise Control. 0.75~75kW 3Phase 200 ~ 230Volts 0.75~375kW 3Phase 380 ~ 480Volts High Torque Performance and Precise Control 0.75~75kW 3Phase 200 ~ 230Volts 0.75~375kW 3Phase 380 ~ 480Volts User-Friendly Options Diverse communication options, expansion I/O options, PLC options, encoder

More information

High Torque Performance and Precise Control. 0.75~75kW 3Phase 200 ~ 230Volts 0.75~160kW 3Phase 380 ~ 480Volts

High Torque Performance and Precise Control. 0.75~75kW 3Phase 200 ~ 230Volts 0.75~160kW 3Phase 380 ~ 480Volts High Torque Performance and Precise Control 0.75~75kW 3Phase 200 ~ 230Volts 0.75~160kW 3Phase 380 ~ 480Volts User-Friendly Options Diverse communication options, expansion I/O options, PLC options, encoder

More information

Miniature Circuit Breakers BK63HU / BK63H

Miniature Circuit Breakers BK63HU / BK63H Miniature Circuit Breakers BK63HU / BK63H BK63H UL89 Ratings BK63HU 1P BK63HU 2P BK63HU 3P Performance UL89 Standard UL89, UL86E(Lug) Protection Overload, Short circuit Rated current 1, 2, 3,, 5, 6, 8,

More information

High Torque Performance and Precise Control. 0.75~22kW 3Phase 200~230Volts 0.75~160kW 3Phase 380~480Volts. Automation Equipment.

High Torque Performance and Precise Control. 0.75~22kW 3Phase 200~230Volts 0.75~160kW 3Phase 380~480Volts. Automation Equipment. High Torque Performance and Precise Control 0.75~22kW 3Phase 200~230Volts 0.75~160kW 3Phase 380~480Volts Automation Equipment www.lgis.com User-Friendly Options Diverse communication options, expansion

More information

Solution Power Medium Voltage Metal Clad Switchgear

Solution Power Medium Voltage Metal Clad Switchgear www.lsis.biz Solution Power Medium Voltage Metal Clad Switchgear Contents Features 12 Ratings 14 Structures and dimensions 16 Accessories and apparatuses 18 Arrangement (for general application) 22 2I

More information

Leader in Electrics & Automation SOLUTION Power Transmission & Distribution

Leader in Electrics & Automation SOLUTION Power Transmission & Distribution Leader in Electrics & Automation Power Transmission & Distribution Being Created by Diversified Industrial Electricity Technology Stabilized Power Supply and Maximization of Energy Efficiency Where there

More information

High Torque Performance and Precise Control 0.75~75kW 3Phase 200 ~ 230Volts 0.75~375kW 3Phase 380 ~ 480Volts

High Torque Performance and Precise Control 0.75~75kW 3Phase 200 ~ 230Volts 0.75~375kW 3Phase 380 ~ 480Volts www.lsis.com High Torque Performance and Precise Control 0.75~75kW 3Phase 200 ~ 230Volts 0.75~375kW 3Phase 380 ~ 480Volts UserFriendly Options Diverse communication options, expansion I/O options, PLC

More information

Manual Motor Starters

Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

Super Solution Retrofit VCB Vacuum Circuit Breakers

Super Solution Retrofit VCB Vacuum Circuit Breakers www.lsis.com Super Solution Retrofit VCB Vacuum Circuit Breakers Susol VCB Susol VCB is full line-up new VCB which has the high interrupting capacity, large current(~50ka, ~4000A), and maximized compatibility

More information

High-Performance Standard Inverter. 0.4~2.2kW 1-Phase 200~230Volts 0.4~15kW 3-Phase 200~230Volts 0.4~75kW 3-Phase 380~480Volts

High-Performance Standard Inverter. 0.4~2.2kW 1-Phase 200~230Volts 0.4~15kW 3-Phase 200~230Volts 0.4~75kW 3-Phase 380~480Volts High-Performance tandard Inverter 0.4~2.2kW 1-Phase 200~230Volts 0.4~15kW 3-Phase 200~230Volts 0.4~75kW 3-Phase 380~480Volts trong power with a compact size! Powerful sensorless control, a diverse range

More information

Tri-MEC LS Medium Voltage Vacuum Contactors

Tri-MEC LS Medium Voltage Vacuum Contactors www.lsis.biz TriMEC LS Medium Voltage Vacuum Contactors TriMECVC Vacuum Contactors Customer satisfaction through quality and servicels medium voltage vacuum contactors LS medium voltage vacuum contactors

More information

Low Voltage Circuit Breakers & Contactors

Low Voltage Circuit Breakers & Contactors Low Voltage Circuit Breakers & Contactors MCB / MS / Mini-MC / EMPR / DMPR / MMS / MCCB / ACB / VCB Electric Equipment Page 4 1, 2, 3 and 4 pole series up to 125AF B, C and D Characteristics Page 6 2 and

More information

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics:

More information

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10

Contents. Compact ACB 1600A. Ratings 03 Ordering 04 Electrical diagram. 06 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Contents Compact ACB 100A Ratings 0 Ordering 04 Electrical diagram 0 Accessories 08 Structure 09 Dimensions 10 Compact ACB 100A Main Characteristics Rated current : Cat.A ~1000A, (Ics:

More information

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS Design The Sabre VRN2a is a compact SF6 insulated Vacuum Ring Main Unit (RMU). The unit can be mounted to the smallest distribution transformer or be sited in

More information

Up to 24kV Modular type Air insulated switchgear

Up to 24kV Modular type Air insulated switchgear Up to 24kV Modular type Air insulated switchgear Contents Features 03 General characteristics 04 Units for function 05 Units for dimensions 06 Configuration 09 Ratings - SM VCB 10 A variety of accessories

More information

High voltage current limiting Fuse links type CEF

High voltage current limiting Fuse links type CEF High voltage current limiting Fuse links type CEF Index 1. General........................................... 9 2. Overvoltages...................................... 9 3. Pre-arcing times and cut-off characteristics..............

More information

GROUP D. Switch & Protective device.

GROUP D. Switch & Protective device. GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated

More information

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low

More information

High-voltage high-breaking capacity VV fuse-links

High-voltage high-breaking capacity VV fuse-links High- high- VV fuse-links [A] (ka) [mω] [W] [A 2 s] [A 2 s] 12 580 4 6,1 57 4 A 20 370 9 17,3 164 6 A 25 260 10 36 340 10 A 46 55 7 161 1 530 16 A 60 37 13 250 2 270 20 A 80 30 15 430 3 750 25 A 105 25

More information

High Voltage DC Relay

High Voltage DC Relay High Voltage DC Relay High Voltage DC Relay Leading you toward a greater future than you imagine Leading Innovation, Creating Tomorrow With over 3 years of experience in electric power and automation solutions,

More information

FUSES. Safety through quality

FUSES. Safety through quality Safety through quality HH HIGH VOLTAGE Over many decades SIBA has developed a global product line of High Voltage Fuses that are comprehensive for any and all applications. Superior engineering, advanced

More information

High-voltage high-breaking capacity VV fuse-links

High-voltage high-breaking capacity VV fuse-links High- high- VV fuse-links imum cold resistance power dissipation pre-arcing I t value total I t value [kv] (mm) I n [A] (ka) [mω] [W] [A s] [A s] 1 580,1 57 A 0 370 9 17,3 1 A 5 00 10 3 30 10 A 55 7 11

More information

Limitor -G General Purpose Fuses

Limitor -G General Purpose Fuses Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear

More information

LSIS Electric Products ACB / MCCB / MCB / MC&TOR / Mini-MS / MMS / EMPR

LSIS Electric Products ACB / MCCB / MCB / MC&TOR / Mini-MS / MMS / EMPR www.lsis.biz LSIS Electric Products ACB / MCCB / MCB / MC&TOR / MiniMS / MMS / EMPR Susol series 85, 100 and 130kA short circuit current with instantaneous at 508V High functional digital trip relays UL

More information

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear Power Systems PU HYOSUNG Standard High-voltage Switchgear ProSWGR Medium Voltage Metal-clad Switchgear Power & Industrial Systems Performance Group Hyosung Power Systems has been continuously enhancing

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

ELECTRIC EUR TERASAKI ELECTRIC (EUR OPE LTD OPE) LT.

ELECTRIC EUR TERASAKI ELECTRIC (EUR OPE LTD OPE) LT. Catalog 07-04 New generation of main switchboards from TERASAKI TERASAKI'S TECHNOLOGY Certificate CE marking Compact TYPE APPROVAL obtained The MS22 is the first low-voltage marine switchboard system in

More information

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000

More information

B4 Load Break Switches

B4 Load Break Switches B4 CONTENTS Features B4-02 Ratings B4-04 Accessories B4-06 Installation Method & Structure B4-08 Control Circuit Diagrams & Dimensions B4-10 Fuse Selection Criterias B4-12 Certifications B4-14 B4-02 LBS

More information

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits Selector guide PSC Square body fuses Size 3X 500-700VAC End Contact Terminals December 2013 Issue 2 The IXYS UK range of 700V/690V protistor fuse links provides maximum flexibility in equipment design

More information

YASKAWA AC DRIVES. Application Solution. Extruder. YASKAWA AC Drive GA700. YASKAWA Matrix Converter U1000

YASKAWA AC DRIVES. Application Solution. Extruder. YASKAWA AC Drive GA700. YASKAWA Matrix Converter U1000 YASKAWA AC DRIVES Application Solution Extruder YASKAWA AC Drive YASKAWA Matrix Converter For Extruder YASKAWA provides the answers to your extruder needs. YASKAWA ELECTRIC always stands in the shoes of

More information

36 / 72.5kV Dry Air Insulated Dead Tank Vacuum Circuit Breaker

36 / 72.5kV Dry Air Insulated Dead Tank Vacuum Circuit Breaker 36 / 72.5kV Dry Air Insulated Dead Tank Vacuum Circuit Breaker 1 Features The Dry Air Insulated Dead Tank VCB was born of superb technology and abundant production experience of Meidensha Corporation.

More information

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4 NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,

More information

PROTECTION AND CONTROL

PROTECTION AND CONTROL B C Table 1 DIMENSIONAL Information for Trans-Guard OS Fuses Fuse Voltage Rating (kv) 1/4-20 threaded hole 1/2 deep (both ends) Current Rating (Amps) Fuse Catalog Number 35 HTDS232035 Overall Diameter

More information

PARALLEL PROCESSING UPS E33A

PARALLEL PROCESSING UPS E33A PARALLEL PROCESSING UPS E33A Low energy, high quality, high reliability parallel processing type UPS E33A Supporting network PARALLEL PROCESSING UPS Parallel operation backup time Input AC380, 400, 415,

More information

Power Systems PU. HYOSUNG MV Gas Insulated Switchgear. ProGIS[MV GIS]

Power Systems PU. HYOSUNG MV Gas Insulated Switchgear. ProGIS[MV GIS] Power Systems PU HYOSUNG MV Gas Insulated Switchgear ProGIS[MV GIS] Power & Industrial Systems Performance Group Hyosung Power Systems has been continuously enhancing customer s value since it started

More information

Rapier AX Air Break Switch Disconnector. engineering brilliant solutions

Rapier AX Air Break Switch Disconnector. engineering brilliant solutions Air Break Switch Disconnector engineering brilliant solutions Air Break Switch Disconnector engineering brilliant solutions Lucy Switchgear would like to present its Air Break Switch Disconnector. The

More information

Motor Protection Circuit Breaker

Motor Protection Circuit Breaker Motor Protection Circuit Breaker Catalogue 2011 CONTENT Introduction...4 Features...4 Parts Identification...5 Technical information (MPCB)...5 Technical information (Aux. contact, Fault signalling contact)...6

More information

Medium Voltage current limiting Fuse links

Medium Voltage current limiting Fuse links Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 200A 1. General information P&C Medium Voltage fuse-links named PCEF are designed

More information

24kV/36kV Metal-Enclosed SF6 Gas Insulated Switchgear HICLAD 20GB/HICLAD 30GB

24kV/36kV Metal-Enclosed SF6 Gas Insulated Switchgear HICLAD 20GB/HICLAD 30GB 24kV/36kV Metal-Enclosed SF6 Gas Insulated Switchgear HICLAD 20GB/HICLAD 30GB Compact, reliable, and economic for medium-voltage applications Design Concept This switchgear conforms to IEC62271-200, and

More information

LS MECAPION SERIES. Products Collection Vol. 2.0

LS MECAPION SERIES. Products Collection Vol. 2.0 LS MECAPION DD MOTOR SERIES Products Collection Vol. 2.0 Direct drive motor reduces the number of mechanical components, and provide an intense mechanical system for highly dynamic applications. It allows

More information

Medium voltage products. Fuses

Medium voltage products. Fuses Medium voltage products Fuses Index Introduction... 3 Main definitions... 4 ABB HV Fuses with Temperature Control Unit... 5 General principles for fuse link selection... 6 CEF... 8 CEF-S... 16 CEF-VT...

More information

B4 Load Break Switch CONTENTS

B4 Load Break Switch CONTENTS B4 Load Break Switch CONTENTS B4-02 Load Break Switch LBS Load Break Switch B4-03 VITZROTECH Load Break Switch is a product developed from the previous model E3-Class and manufactured based on the 100A

More information

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents HHM High Voltage Fuses Motor Circuit Protection DIN and British Standard SIBA Motor Rated Fuses are available in - German DIN Standard and - British Standard Design The large variety in body sizes / mounting

More information

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction. HHD HIGH VOLTAGE GERMAN DIN STANDARD FOR AIR & GAS INSULATED SWITCHGEARS OUTDOOR SWITCHGEARS The striker pin system is connected by means of a high resistance parallel conductor. After melting the main

More information

Photovoltaic Inverter Optimal design for the Best PV System

Photovoltaic Inverter Optimal design for the Best PV System www.lsis.com Photovoltaic Inverter Optimal design for the Best PV System It's Necessary, not an option Powerful & Creative Challenge for the Green Future LSIS goes toward a global leading company in the

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

YASKAWA AC DRIVES. Application Solution. Injection Molding Machine. YASKAWA AC Drive GA700. YASKAWA Matrix Converter U1000

YASKAWA AC DRIVES. Application Solution. Injection Molding Machine. YASKAWA AC Drive GA700. YASKAWA Matrix Converter U1000 YASKAWA AC DRIVES Application Solution Injection Molding Machine YASKAWA AC Drive YASKAWA Matrix Converter For Injection Molding Machine YASKAWA provides the answers to your injection molding machine needs.

More information

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Features: Low maintenance 10,000 mechanical operations (five times ANSI requirements) Simple magnetic actuator Vacuum interruption Definite

More information

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH HH DRIESCHER - High-voltage high breaking capacity fuses from 1 kv up to 36 kv HH HH ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-866 MOOSBURG TEL. +9 87 61 6 81-0 FAX +9 87 61 68 11 37 http://www.driescher.com

More information

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017 HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION March 2017 HV FUSE-LINKS IN THE WORLD UL STANDARD E OR R RATED: AMERICAN STANDARD DIN STANDARD: GERMAN STANDARD FR STANDARD: FRENCH STANDARD BS STANDARD: BRITISH

More information

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection HHD-BPT Selection Guide HHD-BPT, DIN Style, Current-imiting,, Potential Transformer Protection Current ratings [A]; 0.5, 1, 2, 2.5, 3.15, 4, 5 E=192mm Page E=292mm Page E=367mm Page E=442mm Page E=537mm

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

Current Limiting Fuses, CEF Motor Circuits Fuses, CMF. Catalogue 1YMB en. Industrial IT. enabled

Current Limiting Fuses, CEF Motor Circuits Fuses, CMF. Catalogue 1YMB en. Industrial IT. enabled PowerIT PowerIT Current Limiting Fuses, Motor Circuits Fuses, CMF Catalogue 1YMB51-en Industrial IT enabled TM High voltage current limiting fuse links type Rated voltage:,/7,- kv Rated current: - A Index

More information

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic

More information

Medium voltage products. Fuses

Medium voltage products. Fuses Medium voltage products Fuses Index Introduction... 3 Main definitions... 4 ABB HV Fuses with Temperature Control Unit... 5 General principles for fuse link selection... 6 CEF... 8 CEF-S... 16 CEF-VT...

More information

34-SDMS-02 SPECIFICATIONS FOR

34-SDMS-02 SPECIFICATIONS FOR SPECIFICATIONS FOR M V & L V FUSE LINKS This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE

More information

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction. HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After

More information

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium

More information

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6 The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 6 PROTECTIONS 1 FUNCTION OF ELECTRICAL PROTECTION SYSTEMS Problems:

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

Gas Insulated Switchgear

Gas Insulated Switchgear Gas Insulated Switchgear 25.8kV Gas Insulated Switchgear 36kV Gas Insulated Switchgear 72.5kV Gas Insulated Switchgear 145kV Gas Insulated Switchgear 170kV Gas Insulated Switchgear 245kV Gas Insulated

More information

3.2. Current Limiting Fuses. Contents

3.2. Current Limiting Fuses. Contents .2 Contents Description Current Limiting Applications................. Voltage Rating.......................... Interrupting Rating....................... Continuous Current Rating................ Fuse

More information

IEC Standard Back-Up Fuse-Links

IEC Standard Back-Up Fuse-Links 3 / 7.2 kv 6 / 12 kv 10 / 17.5 kv 10 / 24 kv 20 / 36 kv Ferrule German DIN Standard Beyond our line of ANSI / IEEE current-limiting fuses, Mersen offers a full line of medium voltage fuse links according

More information

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A Efficient protection of voltage transformer circuits Extending the lifetime of installed electrical

More information

High Performance Vector Control Drive Manual Supplement

High Performance Vector Control Drive Manual Supplement YASKAWA AC Drive-A1000 High Performance Vector Control Drive Manual Supplement Supplement to: A1000 Quick Start Guide TOEPC71061641C Type: CIMR-AU A Models: 200 V Class: 0.4 to 110 kw (3/4 to 175 HP

More information

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker DR-6/DT-6 COMPACT AND EXTENSIBLE RING MAIN UNIT BUILT TO LAST! DR-6/DT-6 Compact and/or extensible SF 6 insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker SAFETY, RELIABILITY,

More information

Medium Voltage current limiting Fuse links

Medium Voltage current limiting Fuse links Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 0A 1. General information P&C Medium Voltage fuse-links named PCEF are designed to

More information

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgears Introduction Medium voltage fuse-links according to British Standard are back-up fuse-links for the protection of substations up

More information

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV Air Insulated Switchgear TAP17. Technical Data TGOOD MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)

More information

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders ETS12-01-01 Specification ETS12-01-01 Ver 3 Contents 1. Purpose and Scope... 1 2. References...

More information

Padmount Solid Dielectric Switchgear Catalog

Padmount Solid Dielectric Switchgear Catalog Padmount Solid Dielectric Switchgear Catalog p G&W headquarters in Bolingbrook, IL USA Company Profile Since 1905, G&W Electric has helped energize the world with innovative power system solutions. With

More information

VALVCON Universal ADC-Series Sealed Lead Acid Back-Up Battery Upgrade Kits. Installation, Maintenance and Operating Instructions

VALVCON Universal ADC-Series Sealed Lead Acid Back-Up Battery Upgrade Kits. Installation, Maintenance and Operating Instructions VALVCON Universal ADC-Series Sealed Lead Acid Back-Up Battery Upgrade Kits Installation, Maintenance and Operating Instructions IMO-I4830 EN 9/2018 2 IMO-I4830 EN TABLE OF CONTENTS 1. GENERAL... 3 1.1

More information

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

OVERALL LENGTH (B)  ( mm)  ( mm)  ( mm)  ( mm) 1 4-20 threaded hole 1 2" deep (both ends) Dimensional Information NOMINAL CURRENT CAT. NO. 40 HTSS232040 50 HTSS232050 65 HTSS232065 80 HTSS232080 100 HTSS232100 125 HTSS232125 150 HTSS232150 165 HTSS232165

More information

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze

More information

RAPIER DSB Disconnectors

RAPIER DSB Disconnectors RAPIER DSB Disconnectors and Copper and Aluminium Substation Connectors ENGINEERING BRILLIANT SOLUTIONS Rapier DSB disconnector The Rapier Double Side Break 'DSB' range provides a powerful and cost effective

More information

MEDIUM VOLTAGE SWITCHGEAR

MEDIUM VOLTAGE SWITCHGEAR MEDIUM VOLTAGE SWITCHGEAR MEDIUM VOLTAGE SWITCHGEAR Easun Reyrolle is a leader in the field of electrical power management and has more than 30 years of domain expertise in providing a wide spectrum of

More information

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification 543 technical hotline +44 ()1268 56372 Standards and approvals Sentry MCBs are designed to fully comply with the relevant requirements of BS EN 6898: 23. They all feature positive contact status indication

More information

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv 06B1-E-0002 Small Space Requirement, High Reliability and Safety ー 72.5 to 145 kv GIS, SDH314/SDHa314

More information

Ensuring excellent switching capability and high quality with various advantages

Ensuring excellent switching capability and high quality with various advantages VCB Vacuum Circuit Breaker Ensuring excellent switching capability and high quality with various advantages Retaining the high dielectric strength with the interrupter of the high vacuum degree of 10-7

More information

Medium voltage fuses Medium voltage fuses

Medium voltage fuses Medium voltage fuses European Fuses DIN Fuses 7.2kV - 36kV IBD 7.2 UP TO 36 KV HIGH-VOLTAGE FUSES DESIGNED FOR POWER TRANSFORMER PROTECTION INTERIOR/EXTERIOR USE CERAMIC HOUSING MEDIUM CLASS TRIP-INDICATOR COMBINED WITH A

More information

Reliable Hi-Quality Overload Protector

Reliable Hi-Quality Overload Protector Reliable Hi-Quality Overload Protector The Sankyo torque limiter is a safety device designed to protect mechanical equipment from overloads. When an excessive torque load occurs, the torque limiter trips

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

LubePro Series Pumps. For Simple, Injector-based Automatic Lubrication Systems. The Choice of Lubrication Professionals.

LubePro Series Pumps. For Simple, Injector-based Automatic Lubrication Systems. The Choice of Lubrication Professionals. LubePro Series Pumps For Simple, Injector-based Automatic Lubrication Systems The Choice of Lubrication Professionals. As a hard-working professional focused on ensuring your production lines keep moving

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %

More information

Oil and Grease Pumps. Outstanding Performance and Reliability. The Industry s Most Trusted Pumps for:

Oil and Grease Pumps. Outstanding Performance and Reliability. The Industry s Most Trusted Pumps for: Oil and Grease Pumps Outstanding Performance and Reliability The Industry s Most Trusted Pumps for: Fast Lubes and Small Garages Oil Jobbers General Service Shops Dealerships Body Shops Municipalities

More information

SD Series. Cord and Light Reels. Engineered Solutions to Help you Work Smarter and Faster. Quality Cord and Light Reels

SD Series. Cord and Light Reels. Engineered Solutions to Help you Work Smarter and Faster. Quality Cord and Light Reels SD Series Cord and Light Reels Engineered Solutions to Help you Work Smarter and Faster Quality Cord and Light Reels Organize your work space for a safer, more productive work environment. Make Graco your

More information

MEDIUM VOLTAGE DIN Fuse-Links

MEDIUM VOLTAGE DIN Fuse-Links Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 24TDMEJ(amp) 24THMEJ(amp) 24TFMEJ(amp) 24TXMEJ(amp) Class of Operation: Back-up as IEC 60282-1

More information

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS

More information

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A DISTRIBUTION SOLUTIONS Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A Continuous protection and reliable operation Proven design and compliance with newest fuses standards Compatibility with other ABB

More information

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor

More information

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection

More information

High-Voltage Fuse Links according to IEC

High-Voltage Fuse Links according to IEC High-Voltage Fuse Links according to IEC 60282- Limitor Ferraz Shawmut is global leader in fuse-based electrical protection solutions. Our brand is worldwide renowned for technical expertise, innovative

More information

RollerDrive. Ultra small, zero backlash reducer. RollerDrive. MR series

RollerDrive. Ultra small, zero backlash reducer. RollerDrive. MR series RollerDrive MR Ultra small, zero backlash reducer RollerDrive MR series The ZERO-Backlash Technology Superior movement achieved with zero-backlash technology Theory of Operation Roller gear mechanism Output

More information