LG HRC Power Fuses ISO 9001 ISO 14001

Size: px
Start display at page:

Download "LG HRC Power Fuses ISO 9001 ISO 14001"

Transcription

1 LG HRC Power Fuses ISO 900 ISO

2 Current without Power Fuse (ka ms) Ipeak Let through Below 0.5 Cycle voltage(kv) Initiation of arcing(degree) Ipeak(kA) Power Factor ~ 0.5 Test : ka Basis : 3A I peak : Let through (under the short circuit test)

3 Contents Introduction Ratings and specifications Conditions of selection Characteristics curves Fuse holder dimensions Ordering information

4 LG HRC Power Fuses Introduction Features The LG HRC Power Fuses belong to the PRIME MEC series. It interrupts high s before the first loop of fault has reached its natural peak value and therefore cuts down the required withstand capacity of the associated equipment on the electric system. Though small in size, it has a high breaking capacity and its enclosed type is suitable for use inside of the panel board. PRIME MEC fuses are equipped with striker pins for trip indicators as well as for operating the related load break switches. Link type fuse holder enables easy maintenance and high stability when replacing the fuses. With Fuse Checker, checking the conditions of a fuse in the panel board or by telecommunication is possible.(optional) Applied standards IEC -, DIN 35, BS 9, KSC Applications Transformer protection - To protect against short circuit in the secondary part of a transformer and fault in the transformer circuit. Condenser protection - To protect against fault in the condenser circuit. Motor protection - To protect against fault in the motor circuit Cable protection - Fault protection secures the cable Ratings and specification Type LFL-3G-5B LFL-3G-B LFL-3G-B LFL-3G-30B LFL-3G-B LFL-3G-50B LFL-3G-0B LFL-3G-75B LFL-3G-B LFL-3G-5B LFL-3G-0B LFL-3G-0B voltage (kv) 3. (A) Fuse link Breaking (ka, rms) Minimum breaking (A) 3~In In: Dimensions (A) (B) (mm) Weight (kg).0.0. Type LFL-G- DHB LFL-G- DHB Fuse holder voltage (kv) 7. (A) 0 Insulation level (BIL, kv) 5 3

5 Type LFL-G-5B LFL-G-B LFL-G-B LFL-G-30B LFL-G-B LFL-G-50B LFL-G-0B LFL-G-75B LFL-G-B LFL-G-5B LFL-G-0B LFL-G-0B LFL-G-5B LFL-G-B LFL-G-B LFL-G-30B LFL-G-B LFL-G-50B LFL-G-0B LFL-G-75B LFL-G-B LFL-G-5B LFL-G-0B LFL-G-0B LFL-5G-5B LFL-5G-B LFL-5G-B LFL-5G-30B LFL-5G-B LFL-5G-50B LFL-5G-0B LFL-5G-75B LFL-5G-B LFL-G-5B LFL-G-B LFL-G-B LFL-G-30B LFL-G-B LFL-G-50B LFL-G-0B LFL-G-75B LFL-0G-B LFL-G-75B LFL-0G-B LFL-G-5B LFL-G-0B LFL-G-0B LFL-30G-5B LFL-30G-B LFL-30G-B LFL-30G-30B LFL-30G-B LFL-30G-50B LFL-30G-0B (A) Ratings Application site : Indoor use For fuse link & fuse holder type, refer to page 5. voltage (kv) Breaking (ka, rms) 50 5 Minimum breaking (A) 3~In In: 3~In 3~In 3~In 3~In Dimensions (A) (B) (mm) Weight (kg) Type LFL-G-DHB LFL-G-DHB LFL-G- DHB LFL-G- DHB LFL-5G- D0B LFL-5G- DHB LFL-G- DHB LFL-G- DHB LFL-G- DHB LFL-30G- DHB voltage (kv) (A) Insulation level (BIL, kv) Fuse link Fuse holder

6 LG HRC Power Fuses Conditions of selection Basic conditions for selecting the Power Fuses The rated of a Power Fuse should be higher than sum of the total rated of the electric equipment on the circuit. Back-up protection with electric equipment on the circuit. -Set the operating characteristics of the Power Fuses to satisfy the over- characteristics of the protected loads on the circuit. Also, set the occurred calories, by the l t operation, to be smaller than the short-circuit intensity of the electric equipment and circuit. -When using the Power Fuses for backup usage with other protective equipment, set the operating times of the protective equipment below the minimum breaking to be faster than those of the Power Fuses. For transformer protection Circuit Transformer Circuit Transformer Circuit Transformer Circuit Transformer Phase voltage capacity Applied fuses voltage capacity Applied fuses voltage capacity Applied fuses voltage capacity Applied fuses (kv) (kva) (kv) (kva) (kv) (kva) (kv) (kva) ~ LFL-3G-5B ~ LFL-G-5B ~ LFL-G-5B ~3 LFL-G-5B ~3 LFL-3G-B 3~5 LFL-G-B ~5 LFL-G-B 3~90 LFL-G-B 5~3 LFL-3G-B 30~ LFL-G-B 5~3 LFL-G-B 99~ LFL-G-B ~ LFL-3G-30B ~ LFL-G-30B 75~55 LFL-G-30B 9~3 LFL-G-30B ~ LFL-3G-B 0~5 LFL-G-B 33~79 LFL-G-B 7~557 LFL-G-B ф 3.3 9~ LFL-3G-50B. 9~ LFL-G-50B 73~359 LFL-G-50B.9 35~79 LFL-G-50B ~37 LFL-3G-0B 3~75 LFL-G-0B 5~ LFL-G-0B 30~97 LFL-G-0B 3ф 3.3 ~5 LFL-3G-75B 3~330 LFL-G-75B 90~57 LFL-G-75B 50~5 LFL-G-75B ~ LFL-3G-B 5~ LFL-G-B ~73 LFL-G-B 93~57 LFL-G-B 5~75 LFL-3G-5B 30~550 LFL-G-5B ~95 LFL-G-5B 3~90 LFL-G-5B ~35 LFL-3G-0B 5~70 LFL-G-0B 950~ LFL-G-0B 5~3 LFL-G-0B 5~ LFL-3G-0B 37~0 LFL-G-0B 300~55 LFL-G-0B 50~3050 LFL-G-0B.7~ LFL-3G-5B 3~ LFL-G-5B ~37 LFL-G-5B 3~75 LFL-G-5B ~ LFL-3G-B ~ LFL-G-B 37~7 LFL-G-B 75~57 LFL-G-B 5~53 LFL-3G-B 5~7 LFL-G-B 70~79 LFL-G-B 7~35 LFL-G-B 35~73 LFL-3G-30B 70~5 LFL-G-30B 9~9 LFL-G-30B 5~53 LFL-G-30B 9~3 LFL-3G-B 37~ LFL-G-B 3~ LFL-G-B ~95 LFL-G-B 5~77 LFL-3G-50B. 70~35 LFL-G-50B 99~3 LFL-G-50B.9 59~ LFL-G-50B ~3 LFL-3G-0B 9~7 LFL-G-0B 37~777 LFL-G-0B 75~55 LFL-G-0B 7~5 LFL-3G-75B 33~57 LFL-G-75B 500~99 LFL-G-75B 0~93 LFL-G-75B ~3 LFL-3G-B 3~7 LFL-G-B 00~3 LFL-G-B 00~5 LFL-G-B ~7 LFL-3G-5B 5~95 LFL-G-5B ~5 LFL-G-5B 3~330 LFL-G-5B 35~ LFL-3G-0B 735~ LFL-G-0B ~ LFL-G-0B 30~3 LFL-G-0B 59~7 LFL-3G-0B 755~5 LFL-G-0B 9~3 LFL-G-0B 593~57 LFL-G-0B Selecting conditions When ordering 5.5, 3kV Power Fuse, Refer to page 9.. For further information contact the manufacturer. The inrush of a transformer is selected assuming that the is time that of the full-load transformer in 0.sec. The rated of the Power Fuses is selected to continuously flow at.5time of the transformer rated. Power Fuses for proteting against short-circuit in the secondary part of a transformer are selected assuming that the is 5times that of the transformer rated in seconds. 5

7 For condenser protection Circuit Transformer Circuit Condenser Circuit Condenser Circuit Condenser Phase voltage capacity Applied fuses voltage capacity Applied fuses voltage capacity Applied fuses voltage capacity Applied fuses (kv) (kva) (kv) (kva) (kv) (kva) (kv) (kva) ~9. LFL-3G-5B ~9 LFL-G-5B ~ LFL-G-5B ~ LFL-G-5B 9.~ LFL-3G-B 9~ LFL-G-B ~39 LFL-G-B ~3 LFL-G-B ~3 LFL-3G-B ~ LFL-G-B 39~~97 LFL-G-B 3~3 LFL-G-B 3~ LFL-3G-30B ~9 LFL-G-30B 97~5 LFL-G-30B 3~37 LFL-G-30B ~ LFL-3G-B 9~ LFL-G-B 5~ LFL-G-B 37~5 LFL-G-B 3ф 3.3 ~ LFL-3G-50B. ~3 LFL-G-50B ~70 LFL-G-50B.9 5~5 LFL-G-50B ~5 LFL-3G-0B 3~ LFL-G-0B 70~3 LFL-G-0B 5~7 LFL-G-0B 5~50 LFL-3G-75B ~300 LFL-G-75B 3~90 LFL-G-75B 7~ LFL-G-75B 50~ LFL-3G-B 300~5 LFL-G-B 90~795 LFL-G-B ~55 LFL-G-B ~75 LFL-3G-5B 5~550 LFL-G-5B 795~3 LFL-G-5B 55~370 LFL-G-5B 75~370 LFL-3G-0B 550~7 LFL-G-0B 3~5 LFL-G-0B 370~370 LFL-G-0B 370~500 LFL-3G-0B 7~0 LFL-G-0B 5~9 LFL-G-0B 370~00 LFL-G-0B Selecting conditions The inrush of a condenser is selected to withstand 7time of the condenser rated in 0.00sec. The rated of the Power Fuses is selected to continuously flow at.3 times of the condenser rated. For motor protection For cable protection Circuit Circuit Phase voltage Motor output Applied fuses voltage Motor output Applied fuses (kv) (kva) (kv) (kva) Cable diameter (mm ) (A) of PF (A).5~.7 LFL-3G-5B 3~ LFL-G-5B.7~ LFL-3G-B ~3 LFL-G-B ~57 LFL-3G-B 3~ LFL-G-B 50~5 LFL-3G-30B ~7 LFL-G-30B 5~5 LFL-3G-B 7~30 LFL-G-B 3ф 3.3 5~ LFL-3G-50B. 30~ LFL-G-50B 3~9 LFL-3G-0B 7~3 LFL-G-0B ~5 LFL-3G-75B 3~503 LFL-G-75B 35~39 LFL-3G-B 9~739 LFL-G-B 93~35 LFL-3G-5B 5~70 LFL-G-5B 33~57 LFL-3G-0B 75~3 LFL-G-0B 375~30 LFL-3G-0B 5~70 LFL-G-0B Selecting conditions The starting of a motor is selected to withstand 5 times of the full-loads in sec. Under the short-circuit condition, the power fuse breaks the circuit in high speed. Therefore, with relatively high rated, the Power Fuse protects small size cables. Selected to protect from above times of the short-circuit.

8 LG HRC Power Fuses Characteristics curves A A 75A 3A 50A A 30A A A 5A A 5A 0 A A 0 A 75A A A 3A Cut-off (peak value:ka) Operating time (sec) A Prospective breaking (rms : ka) Prospective rated (rms : A) A 0A /7.kV Cut-off characteristics 3./7.kV Pre-arcing time characteristics 3.kV Cut-off characteristics 3.kV Pre-arcing time characteristics A 0A 0 0 Cut-off (peak value:ka) Operating time (sec) Prospective breaking (rms : ka) Prospective rated (rms : A) 7

9 kV Cut-off characteristics 7.kV Pre-arcing time characteristics A 0A 0 0 Cut-off (peak value:ka) 0A 0A Operating time (sec) Prospective breaking (rms : ka) Prospective rated (rms : A) 5.5kV Cut-off characteristics 5.5kV Pre-arcing time characteristics Cut-off (peak value:ka) A 75A 3A 50A A 30A A A 5A Operating time (sec) A A A 5A A 75A 3A 50A A Prospective breaking (rms : ka) Prospective rated (rms : A)

10 LG HRC Power Fuses Characteristics curves kv Cut-off characteristics kv Pre-arcing time characteristics A 0A 0 A 0A 0 A 5A Cut-off (peak value:ka) 0A 0A 5A A 75A 3A 50A A 30A A A 5A Operating time (sec) A A 50A A 75A 3A Prospective breaking (rms : ka) Prospective rated (rms : A) 3kV Cut-off characteristics 3kV Pre-arcing time characteristics Cut-off (peak value:ka) A 50A A 30A A A 5A Operating time (sec) A 50A A 30A A A 5A Prospective breaking (rms : ka) Prospective rated (rms : A) 9

11 Striker operating characterstics Operating weight (kgf) Operating distance(mm) Operating characteristics of the Power Fuses The characteristics of the Power Fuses are native and fixed. Therefore it can not be regulated like a circuit breaker or overload relay. When ordering, please select the Power Fuses with proper and operating characteristics by considering its usage and circuit condition. Breaking a small. Power Fuses are not adequate to protect small. So, the manufacturer specifies and guarantees the minimum breaking by regulation. ) Select the rated of the Power Fuse, which does not operate below the minimum breaking. ) Protect the below the minimum value by use of other protective equipment.

12 LG HRC Power Fuses Fuse holder dimensions Indoor use Power Fuse holder LFH-G-DHB Type C (Peak height in open condition) 50 B 0.5 ф.5(hold) 70 Fuse size(a) B C ф ф Mounting hold 5 Earth hole Below Fuse checker Indoor use Power Fuse holder LFH-G-DHB/LFH-G-DHB/LFH-5G-D0B Type 5.5 (Peak height in open condition) ф.5(hold) 70 Fuse size(a) B C D Applied Holder ф LFH-G-DHB Mounting hole ф LFH-5G-D0B Earth hole 5 Fuse size(a) B C D Applied Holder ф LFH-G-DHB Below Fuse checker Indoor use Power Fuse holder LFH-G-DHB/LFH-5G-DHB/LFH-DHB LFH-30G-D0B Type C (Peak height in open condition) B ф.5(hold) Mounting hold Fuse size(a) B C D E Applied Holder Earth hole 5 ф LFH-G-DHB ф LFH-5G-DHB ф LFH-G-DHB Fuse size(a) B C D E Applied Holder 3.7 Fuse checker 35 ф LFH-30G-D0B ф

13 A Power Fuse holder E B C D Panel Conductor Panel E F E F Circuit Insulation Dimensions(mm) PH Holder type voltage voltage level Applied fuse (kv) (A) (kv) (BIL, kv) A B C D E F LFL-3G-5B, B, B, 30B, B, 50B LFH-G-DHB LFL-3G-0B, 75B, B LFL-G-5B, B, B, 30B, B, 50B LFL-G-0B, 75B, B LFH-G-DHB LFL-3G-5B, 0B, 0B LFL-G-5B, 0B, 0B LFL-G-5B, B, B LFH-G-DHB LFL-G-30B, B, 50B, 0B LFL-G-75C, C 5B, 0B, 0B

14 LG HRC Power Fuses Ordering information Types of P/F Link & P/F Holder P/F Link LFH Model name General use Revision No. voltage 3 3.kV 7.kV kv 5 5.5kV kv 30 3kV A A A 30A A 50A 3A 75A A 5A 0A 0A P/F Holder LFH Model name General use Indoor use Revision No. voltage 3./7.kV kv 5 5.5kV kv 30 3kV 0 3A H A H 0A Fuse checker 0 Without with 3

15 Basic conditions for selecting the Power Fuse Ratings Operating Voltage ( V) Frequency ( Hz) Ampere ( A) Breaking capacity ( kv) Schematic diagram of the installation Initial symmetrical short-circuit of the primary network power/impedance/reactance/voltage generators/transformers/reactors capacity of motors (over MW) capacity of capacitor bank and the inductance connected in series with them. Applications Transformers Set to allow continuous flow at.5 times of the rated of a transformer and to break at 5 times of the rated of a transformer within seconds when a short circuit condition occurs in the secondary part. Condenser - Inrush : set to allow flows at 7 times of the rated of a condenser for 0.00 seconds. - : set to allow continuous flows at.3 times of the rated of a condenser. Motor Cable Upstream protection by circuit breakers or contactors Operation & accessories Installed site Indoor Outdoor Fuse holder(base) Not needed Needed Fuse checker Not needed needed Example of ordering voltage : kv, Hz : 0Hz, : 0A, Breaking capacity : ka Application Upstream protection with circuit breaker Installed site Indoor Out door Fuse holder Not needed Needed Fuse checker Not needed Needed LFH-G-0B/LFH-G-D H B When ordering, please include this sheet

16 03-0 Safety Instructions For your safety, please read user s manual thoroughly before operating. Contact the nearest authorized service facility for examination, repair, or adjustment. Please contact qualified service technician when you need maintenance. Do not disassemble or repair by yourself! Any maintenance and inspection shall be performed by the personnel having expertise concerned. srjo@hn.vnn.vn LG Industrial Trading (Shanghai) Co., Ltd China Address: Room , 7th Floor Xinda Commerical Building No 3, Xian Xia Road Shanahai Tel: Fax: hgseo@lgis.com Room 303, 3F LG Industrial Systems Shanghai Office China Address: Room , 7th Floor Xinda Commerical Building No 3, Xian Xia Road Shanahai, China Tel: Fax: sdhwang@lgis.com LG Industrial Systems Guangzhou Office China Address: Room 303, 3F, Zheng Sheng Building, No 5-, Tian He Bei Road, Guangzhou, China Tel: Fax: Specifications in this catalog are subject to change without notice due to continuous product development and improvement. younsupl@lgisusa.com HRC(A) 0 / Aug. 03 Printed in Korea STAFF

Prime-MEC LS HRC Power Fuses

Prime-MEC LS HRC Power Fuses www.lsis.biz Prime-MEC LS HRC Power Fuses Current without Power Fuse (ka ms) Ipeak Let through current Below 0.5 Cycle Rated voltage(kv) 3. 7. Initiation of arcing(degree) 5 5 90 5 70 9 7 5 5 Ipeak(kA).5

More information

Manual Motor Starters

Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000

More information

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low

More information

High voltage current limiting Fuse links type CEF

High voltage current limiting Fuse links type CEF High voltage current limiting Fuse links type CEF Index 1. General........................................... 9 2. Overvoltages...................................... 9 3. Pre-arcing times and cut-off characteristics..............

More information

High-voltage high-breaking capacity VV fuse-links

High-voltage high-breaking capacity VV fuse-links High- high- VV fuse-links [A] (ka) [mω] [W] [A 2 s] [A 2 s] 12 580 4 6,1 57 4 A 20 370 9 17,3 164 6 A 25 260 10 36 340 10 A 46 55 7 161 1 530 16 A 60 37 13 250 2 270 20 A 80 30 15 430 3 750 25 A 105 25

More information

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4 NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,

More information

Limitor -G General Purpose Fuses

Limitor -G General Purpose Fuses Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear

More information

High-voltage high-breaking capacity VV fuse-links

High-voltage high-breaking capacity VV fuse-links High- high- VV fuse-links imum cold resistance power dissipation pre-arcing I t value total I t value [kv] (mm) I n [A] (ka) [mω] [W] [A s] [A s] 1 580,1 57 A 0 370 9 17,3 1 A 5 00 10 3 30 10 A 55 7 11

More information

FUSES. Safety through quality

FUSES. Safety through quality Safety through quality HH HIGH VOLTAGE Over many decades SIBA has developed a global product line of High Voltage Fuses that are comprehensive for any and all applications. Superior engineering, advanced

More information

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %

More information

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Features: Low maintenance 10,000 mechanical operations (five times ANSI requirements) Simple magnetic actuator Vacuum interruption Definite

More information

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium

More information

Protistor size 70 gr 690VAC (IEC)

Protistor size 70 gr 690VAC (IEC) Protistor size 70 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Excellent cycling capability Multiple body sizes and terminals or blades combination

More information

B4 Load Break Switches

B4 Load Break Switches B4 CONTENTS Features B4-02 Ratings B4-04 Accessories B4-06 Installation Method & Structure B4-08 Control Circuit Diagrams & Dimensions B4-10 Fuse Selection Criterias B4-12 Certifications B4-14 B4-02 LBS

More information

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic

More information

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH HH DRIESCHER - High-voltage high breaking capacity fuses from 1 kv up to 36 kv HH HH ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-866 MOOSBURG TEL. +9 87 61 6 81-0 FAX +9 87 61 68 11 37 http://www.driescher.com

More information

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A DISTRIBUTION SOLUTIONS Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A Continuous protection and reliable operation Proven design and compliance with newest fuses standards Compatibility with other ABB

More information

PROTECTION AND CONTROL

PROTECTION AND CONTROL B C Table 1 DIMENSIONAL Information for Trans-Guard OS Fuses Fuse Voltage Rating (kv) 1/4-20 threaded hole 1/2 deep (both ends) Current Rating (Amps) Fuse Catalog Number 35 HTDS232035 Overall Diameter

More information

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS

More information

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017 HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION March 2017 HV FUSE-LINKS IN THE WORLD UL STANDARD E OR R RATED: AMERICAN STANDARD DIN STANDARD: GERMAN STANDARD FR STANDARD: FRENCH STANDARD BS STANDARD: BRITISH

More information

MEDIUM VOLTAGE DIN Fuse-Links

MEDIUM VOLTAGE DIN Fuse-Links Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 24TDMEJ(amp) 24THMEJ(amp) 24TFMEJ(amp) 24TXMEJ(amp) Class of Operation: Back-up as IEC 60282-1

More information

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection

More information

Tri-MEC Load Break Switch

Tri-MEC Load Break Switch Leader in Electrics & Automation Tri-MEC Load Break Switch Electric Equipment Leader in the field of industrial electricity & automation creating the comfortable and productive society through providing

More information

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV. DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them

More information

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection HHD-BPT Selection Guide HHD-BPT, DIN Style, Current-imiting,, Potential Transformer Protection Current ratings [A]; 0.5, 1, 2, 2.5, 3.15, 4, 5 E=192mm Page E=292mm Page E=367mm Page E=442mm Page E=537mm

More information

Medium voltage products. Fuses

Medium voltage products. Fuses Medium voltage products Fuses Index Introduction... 3 Main definitions... 4 ABB HV Fuses with Temperature Control Unit... 5 General principles for fuse link selection... 6 CEF... 8 CEF-S... 16 CEF-VT...

More information

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction. HHD HIGH VOLTAGE GERMAN DIN STANDARD FOR AIR & GAS INSULATED SWITCHGEARS OUTDOOR SWITCHGEARS The striker pin system is connected by means of a high resistance parallel conductor. After melting the main

More information

EUROPEAN HIGH VOLTAGE FUSES

EUROPEAN HIGH VOLTAGE FUSES EUROPEAN HIGH VOLTAGE FUSES AS PER IEC 60282 EDUPACK TRAINING MODULE 2012 HH DIN NF MEDIUM OR HIGH VOLTAGE FUSE? High Voltage is the official definition provided by the standard. High Voltage starts just

More information

Medium voltage products. Fuses

Medium voltage products. Fuses Medium voltage products Fuses Index Introduction... 3 Main definitions... 4 ABB HV Fuses with Temperature Control Unit... 5 General principles for fuse link selection... 6 CEF... 8 CEF-S... 16 CEF-VT...

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

MEDIUM VOLTAGE DIN Fuse-Links

MEDIUM VOLTAGE DIN Fuse-Links Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 12TDLEJ(amp) 12THLEJ(amp) 12TKLEJ(amp) 12TXLEJ(amp) 12TFMSJ(amp) Class of Operation: Back-up

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction. HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After

More information

Leader in Electrics & Automation SOLUTION Power Transmission & Distribution

Leader in Electrics & Automation SOLUTION Power Transmission & Distribution Leader in Electrics & Automation Power Transmission & Distribution Being Created by Diversified Industrial Electricity Technology Stabilized Power Supply and Maximization of Energy Efficiency Where there

More information

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents HHM High Voltage Fuses Motor Circuit Protection DIN and British Standard SIBA Motor Rated Fuses are available in - German DIN Standard and - British Standard Design The large variety in body sizes / mounting

More information

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A Efficient protection of voltage transformer circuits Extending the lifetime of installed electrical

More information

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits Selector guide PSC Square body fuses Size 3X 500-700VAC End Contact Terminals December 2013 Issue 2 The IXYS UK range of 700V/690V protistor fuse links provides maximum flexibility in equipment design

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear

More information

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

OVERALL LENGTH (B)  ( mm)  ( mm)  ( mm)  ( mm) 1 4-20 threaded hole 1 2" deep (both ends) Dimensional Information NOMINAL CURRENT CAT. NO. 40 HTSS232040 50 HTSS232050 65 HTSS232065 80 HTSS232080 100 HTSS232100 125 HTSS232125 150 HTSS232150 165 HTSS232165

More information

Transforming Energy.. For Advanced Technology

Transforming Energy.. For Advanced Technology Transforming Energy.. Manufacturers of CE approved Transformers & Reactors Five Decades of Manufacturing Experience Manufacturers of Quality Reliable Transformers. Auto C 201,4 th Cross Peenya Induatrial

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

3.2. Current Limiting Fuses. Contents

3.2. Current Limiting Fuses. Contents .2 Contents Description Current Limiting Applications................. Voltage Rating.......................... Interrupting Rating....................... Continuous Current Rating................ Fuse

More information

Current Limiting Fuses, CEF Motor Circuits Fuses, CMF. Catalogue 1YMB en. Industrial IT. enabled

Current Limiting Fuses, CEF Motor Circuits Fuses, CMF. Catalogue 1YMB en. Industrial IT. enabled PowerIT PowerIT Current Limiting Fuses, Motor Circuits Fuses, CMF Catalogue 1YMB51-en Industrial IT enabled TM High voltage current limiting fuse links type Rated voltage:,/7,- kv Rated current: - A Index

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN

More information

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air) Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear ETS12-01-02 Specification ETS12-01-02 Ver 3 Contents 1. Purpose

More information

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification 543 technical hotline +44 ()1268 56372 Standards and approvals Sentry MCBs are designed to fully comply with the relevant requirements of BS EN 6898: 23. They all feature positive contact status indication

More information

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION Fusing Equipment Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly Electrical Apparatus 40-40 GENERAL Cooper Power Systems Bay-O-Net Fuse Assemblies are used to protect transformers and distribution

More information

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E. MOLDED CASE CIRCUIT BREAKER BASICS David Castor, P.E. History of MCCBs 1904 - Cutter Manufacturing Co., Philadelphia, produces circuit breakers. They called it the Inverse Time Element breaker, or I-T-E

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV Air Insulated Switchgear TAP17. Technical Data TGOOD MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)

More information

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

K-Limiter high ampere Companion II fuse

K-Limiter high ampere Companion II fuse Fusing Equipment Catalog Data CA132059EN Supersedes February 2016 COOPER POWER SERIES K-Limiter high ampere Companion II fuse General Eaton designs its Cooper Power series K-Limiter fuse to be conveniently

More information

Semiconductor Fuses European Fuses

Semiconductor Fuses European Fuses 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos

More information

onlinecomponents.com

onlinecomponents.com 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090529 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW Line/Load Reactors are components designed to improve the

More information

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders ETS12-01-01 Specification ETS12-01-01 Ver 3 Contents 1. Purpose and Scope... 1 2. References...

More information

EMPAC Metal enclosed capacitor bank for wind applications

EMPAC Metal enclosed capacitor bank for wind applications EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks

More information

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker DR-6/DT-6 COMPACT AND EXTENSIBLE RING MAIN UNIT BUILT TO LAST! DR-6/DT-6 Compact and/or extensible SF 6 insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker SAFETY, RELIABILITY,

More information

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2. Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.12 Product Overview ABB's type-tested ring main unit (RMU) is an SF 6 insulated RMU utilising the latest developments

More information

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A. LCL FILTERS INSTRUCTIONS MANUAL (M98121701-03-09A) (c) CIRCUTOR S.A. ------ LCL filters: Instructions Manual ----- Page 2 TABLE OF CONTENTS TABLE OF CONTENTS 2 1 CHECKS ON RECEIPT OF THE EQUIPMENT. 3 2

More information

GROUP D. Switch & Protective device.

GROUP D. Switch & Protective device. GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated

More information

34-SDMS-02 SPECIFICATIONS FOR

34-SDMS-02 SPECIFICATIONS FOR SPECIFICATIONS FOR M V & L V FUSE LINKS This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE

More information

Medium Voltage current limiting Fuse links

Medium Voltage current limiting Fuse links Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 200A 1. General information P&C Medium Voltage fuse-links named PCEF are designed

More information

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best. Medium Voltage Power Factor Correction Reactive Compensation Harmonic Filters POWER QUALITY Electrical Power Quality Management at its best. From electricity generation, transmission, thru its distribution

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Paramount HRC Cartridge

Paramount HRC Cartridge Paramount HRC Cartridge Eaton MEM HRC fuselinks are manufactured to exacting standards using precision assembly methods and undergo rigorous quality checking before dispatch including resistance testing

More information

Mica Element Support. Compacted Quartz Sand. Length B

Mica Element Support. Compacted Quartz Sand. Length B Construction A Tin-Plated Brass Caps Dimensional Information for Trans-Guard s NOMINAL 5.5 Resin-Rich Filament Wound Glass/Epoxy Body 3 75 80 200 3 50 5 80 5 125 3 50 5 5 100 23.0 50 Low Current Interruption

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as

More information

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS Design The Sabre VRN2a is a compact SF6 insulated Vacuum Ring Main Unit (RMU). The unit can be mounted to the smallest distribution transformer or be sited in

More information

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX File: PCUP-09-002_EX Outdoor Use Indoor Use The Trans-Guard EX full-range current-limiting capacitor fuse provides both low and high current fault protection in a single, compact fuse body. As a full-range

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Medium voltage fuses Medium voltage fuses

Medium voltage fuses Medium voltage fuses European Fuses DIN Fuses 7.2kV - 36kV IBD 7.2 UP TO 36 KV HIGH-VOLTAGE FUSES DESIGNED FOR POWER TRANSFORMER PROTECTION INTERIOR/EXTERIOR USE CERAMIC HOUSING MEDIUM CLASS TRIP-INDICATOR COMBINED WITH A

More information

IEC Standard Back-Up Fuse-Links

IEC Standard Back-Up Fuse-Links 3 / 7.2 kv 6 / 12 kv 10 / 17.5 kv 10 / 24 kv 20 / 36 kv Ferrule German DIN Standard Beyond our line of ANSI / IEEE current-limiting fuses, Mersen offers a full line of medium voltage fuse links according

More information

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC

More information

3TM Vacuum Contactors

3TM Vacuum Contactors Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents

More information

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3 IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade

More information

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,

More information

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil) Ergon Energy Corporation Limited Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear ETS12-01-03 Specification ETS12-01-03 Ver 3 Contents 1. Purpose and Scope...

More information

Extensible Unit - VCE2a

Extensible Unit - VCE2a ELECTRICAL INDUSTRIAL COMPANY (EICo) LUCY SWITCHGEAR Extensible Unit - VCE2a (Sabre) Electrical Industrial Company (EICo) Lucy Switchgear Extensible Unit VCE2a Front Panel: ELECTRICAL INDUSTRIAL COMPANY

More information

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgears Introduction Medium voltage fuse-links according to British Standard are back-up fuse-links for the protection of substations up

More information

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc. DO-III DO-III Fuse Holder TPL 44-835, May 2000, Page 1 of 4 General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder ABB Inc. General Description The ABB DO-III fuse holder is a draw

More information

Development and Operational Advantages of a Solid State Circuit Breaker with Current Limiting

Development and Operational Advantages of a Solid State Circuit Breaker with Current Limiting Development and Operational Advantages of a Solid State Circuit Breaker with Current Limiting Breaker Technology Operational Advantages Development Schedule Dave Richardson, Ph.D.,P.E. Powell Power Electronic

More information

Miniature & Moulded Case

Miniature & Moulded Case Miniature & Moulded Case MCB OPERATION MAGNETIC OPERATION The short time protection (typically less than 1 second after energising) of the MCB is defined as the magnetic operation. 1 2 3 THERMAL OPERATION

More information

Motor Protection Circuit Breaker

Motor Protection Circuit Breaker Motor Protection Circuit Breaker Catalogue 2011 CONTENT Introduction...4 Features...4 Parts Identification...5 Technical information (MPCB)...5 Technical information (Aux. contact, Fault signalling contact)...6

More information

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter Outdoor Distribution (5 kv through 25 kv) S&C Fault Tamer Fuse Limiter Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles

More information

MESG 12 / 17.5 / 24 / 36 KV

MESG 12 / 17.5 / 24 / 36 KV MESG 12 / 17.5 / 24 / 36 KV Medium Voltage Air Insulated Metal Enclosed Switchgear up to 36 kv- up to 1250 A - up to 25 ka for 1 sec. with SF6 or vacuum circuit breakers. 750 METAL ENCLOSED 1 1 ) GENERAL

More information

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION Fusing Equipment Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly Electrical Apparatus 240-40 GENERAL Cooper Power Systems Bay-O-Net Fuse Assemblies are used to protect transformers and distribution

More information

High-Voltage Fuse Links according to IEC

High-Voltage Fuse Links according to IEC High-Voltage Fuse Links according to IEC 60282- Limitor Ferraz Shawmut is global leader in fuse-based electrical protection solutions. Our brand is worldwide renowned for technical expertise, innovative

More information

Medium voltage fuses - European Fuses

Medium voltage fuses - European Fuses HV Back-up Fuse-Links according to IEC 60 282- HV fuse-links have been used for reliable protection in medium-voltage switchgear and controlgear and systems for decades. They protect apparatus and equipment

More information