NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4
|
|
- Asher Singleton
- 5 years ago
- Views:
Transcription
1 NH fuse-links am VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose, motor circuit protection STANDARDS The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. TECHNICAL DATA OVERVIEW Voltage Range AC VAC Ampere Range (A) A Size per Standard Sizes 0 to 4 - with striker Speed/Characteristic am I.R. AC ka Body Material ceramic Contact Materials copper, silver-plated VDE 0636 Part 201 IEC and -2 EP.MERSEN.COM 1
2 PRODUCT RANGE Size 0 am with striker Catalog Reference Rated voltage AC (IEC) Rated current In Rated breaking capacity AC Power dissipation at In Weight NH0AM69V125P-2 NH0AM69V32P-2 Z V 32 A 80 ka 2.4 W kg NH0AM69V40P-2 R V 40 A 80 ka 2.8 W kg NH0AM69V50P-2 V V 50 A 80 ka 3.6 W kg NH0AM69V63P-2 Y V 63 A 80 ka 4.6 W kg NH0AM69V80P-2 C V 80 A 80 ka 6 W kg NH0AM69V100P-2 F V 100 A 80 ka 7.5 W kg NH0AM69V125P-2 L V 125 A 80 ka 9.5 W kg NH0AM69V160P-2 J V 160 A 80 ka 12 W kg NH0AM50V200P-2 X V 200 A 120 ka kg Size 1 am with striker Catalog Reference Rated voltage AC (IEC) Rated current In Rated breaking capacity AC Power dissipation at In Weight NH1AM69V250P-2 NH1AM69V80P-2 C V 80 A 80 ka 6 W kg NH1AM69V100P-2 M V 100 A 80 ka 7.5 W kg NH1AM69V125P-2 A V 125 A 80 ka 9.9 W kg NH1AM69V160P-2 P V 160 A 80 ka 12.7 W kg NH1AM69V200P-2 B V 200 A 80 ka 16.4 W kg NH1AM69V250P-2 T V 250 A 80 ka 21.5 W kg NH1AM50V315P-2 A V 315 A 120 ka kg Size 2 am with striker NH2AM69V315P-2 NH3AM50V630P-2 Catalog Reference Rated voltage AC (IEC) Rated current In Rated breaking capacity AC Power dissipation at In Weight NH2AM69V125P-2 S V 125 A 80 ka kg NH2AM69V160P-2 B V 160 A 80 ka 12.7 W kg NH2AM69V200P-2 Y V 200 A 80 ka 16.4 W kg NH2AM69V224P-2 P V 224 A 80 ka 18.7 W kg NH2AM69V250P-2 Y V 250 A 80 ka 21.5 W kg NH2AM69V315P-2 N V 315 A 80 ka 29 W kg NH2AM69V355P-2 A V 355 A 80 ka 32 W kg NH2AM69V400P-2 S V 400 A 80 ka 34 W kg NH2AM50V500P-2 W V 500 A 120 ka kg Size 3 am with striker Catalog Reference Rated voltage AC (IEC) Rated current In Rated breaking capacity AC Power dissipation at In Weight NH3AM69V315P-2 Z V 315 A 80 ka 25 W kg NH3AM69V355P-2 D V 355 A 80 ka 29 W kg NH3AM69V400P-2 G V 400 A 80 ka 34 W kg NH3AM69V500P-2 M V 500 A 80 ka 45 W kg NH3AM50V630P-2 K V 630 A 120 ka 60 W kg Size 4 am with striker Catalog Reference Rated voltage AC (IEC) Rated current In Rated breaking capacity AC Power dissipation at In Weight NH4AM69V500P-2 P V 500 A 120 ka 38 W 2.2 kg NH4AM69V630P-2 Q V 630 A 120 ka 50 W 2.2 kg NH4AM69V800P-2 R V 800 A 120 ka 65 W 2.2 kg NH4AM69VP-2 Y V A 120 ka 80 W 2.2 kg NH4AM50V1250P-2 Z V 1250 A 120 ka 100 W 2.2 kg EP.MERSEN.COM 2
3 TECHNICAL DATA Size 0 am with striker Size 1 am with striker Size 2 am with striker Size 3 am with striker Size 4 am with striker Rated current A A A A A Rated voltage AC V V V V V Indication System with striker with striker with striker with striker with striker TIME CURRENT CHARACTERISTIC CURVES Size , 690V am Pre-arcing time (s) A 40 A 50 A 63 A 80 A 100 A 125 A 160 A 200 A 224 A RMS value of prospective current (A) +/- 8% 250 A 315 A 355 A 400 A 500 A 0 EP.MERSEN.COM 3
4 TIME CURRENT CHARACTERISTIC CURVES Size 4, 690V am Pre-arcing time (s) A 630 A 800 A A RMS value of prospective current (A) +/- 8% e+06 EP.MERSEN.COM 4
5 TIME CURRENT CHARACTERISTIC CURVES Size , 500V am Pre-arcing time (s) A A A RMS value of prospective current (A) +/- 8% 200 A 0 EP.MERSEN.COM 5
6 TIME CURRENT CHARACTERISTIC CURVES Size 4, 500V am Pre-arcing time (s) A RMS value of prospective current (A) +/- 8% e+06 EP.MERSEN.COM 6
7 CUT-OFF CURRENT CHARACTERISTIC Size 0-1, 690V am lm = 2.3 lp 250 A 200 A Maximum peak let thru current Ic (A) A 125 A 100 A 80 A 63 A 50 A 40 A 32 A 0 0 1e Hz RMS symmetrical prospective current Ip (A) Size 2, 690V am 0 Maximum peak let thru current Ic (A) lm = 2.3 lp Hz RMS symmetrical prospective current Ip (A) A 355 A 315 A 250 A 224 A 200 A 160 A 125 A 0 0 1e+06 EP.MERSEN.COM 7
8 CUT-OFF CURRENT CHARACTERISTIC Size 3, 690V am 0 lm = 2.3 lp 500 A 400 A Maximum peak let thru current Ic (A) Hz RMS symmetrical prospective current Ip (A) 355 A 315 A e+06 Size 4, 690V am Maximum peak let thru current Ic (A) 0 A lm= 2.3 lp 800 A 630 A 500 A Hz RMS symmetrical prospective current Ip (A) 1e+06 EP.MERSEN.COM 8
9 CUT-OFF CURRENT CHARACTERISTIC Size , 500V am 0 lm = 2.3 lp 630 A 500 A 315 A Maximum peak let thru current Ic (A) 200 A Hz RMS symmetrical prospective current Ip (A) e+06 Size 4, 500V am Maximum peak let thru current Ic (A) A lm = 2.3 lp Hz RMS symmetrical prospective current Ip (A) 1e+06 EP.MERSEN.COM 9
10 PRE-ARCING AND OPERATING I²T CHARACTERISTICS Size , 690V am V 500V pre-arcing I²t 0 Rated current (A) Pre-arcing and operating I²t (A²s) EP.MERSEN.COM 10
11 PRE-ARCING AND OPERATING I²T CHARACTERISTICS Size 4, 690V am V 400V prearcing I²t Rated current (A) Pre-arcing and operating I²t (A²s) Size , 500V am Rated current (A) V 380V pre-arcing I²t Pre-arcing and operating I²t (A²s) 630 EP.MERSEN.COM 11
12 PRE-ARCING AND OPERATING I²T CHARACTERISTICS Size 4, 500V am V 400V prearcing I²t 00 Rated current (A) Pre-arcing and operating I²t (A²s) EP.MERSEN.COM 12
13 DIMENSIONS Size 0 (126458) ± ± ± 0.25 Striker is visible after fuse link has operated Ø 5.5 Ø 8 6 ± Dimensions in mm ± ± ±0.8 EP.MERSEN.COM 13
14 DIMENSIONS Size 1 (126503) 20 ±0.2 Ø ± ± ± 0.25 Striker is visible after fuse link has operated Ø Dimensions in mm ± ± ± ± ±0.7 EP.MERSEN.COM 14
15 DIMENSIONS Size 2 (126505) Ø ± ± ± Striker is visible after fuse link has operated Ø Dimensions in mm 67.6 ± ± ± ± ± 1 56 ±1 EP.MERSEN.COM 15
16 DIMENSIONS Size 3 (126508) ± ± ± ±2.5 Striker is visible after fuse link has operated Dimensions in mm ± ± EP.MERSEN.COM 16
17 DIMENSIONS Size 4 ( ) 68.5 ± ± ± ± Ø ± ± ± (79.5) ± ±0.1 Ø (5.5) Striker is visible after fuse link has operated Dimensions in mm blown 16.6 EP.MERSEN.COM 17
NH fuse-links am 690VAC top indicator/live tags size 4, 4a
NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %
More informationNH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a
LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection
More informationNH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a
NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium
More informationNH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3
NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS
More informationNH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3
IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade
More informationProtistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor
More informationProtistor size 70 gr 690VAC (IEC)
Protistor size 70 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Excellent cycling capability Multiple body sizes and terminals or blades combination
More informationLimitor -G General Purpose Fuses
Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear
More informationNEOZED D0 fuse-links gg 400/440VAC
NEOZED D0 fuse-links gg 400/440VAC LOW VOLTAGE IEC FUSES DIN LV FUSE-LINKS D0 FEATURES & BENEFITS The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non
More informationProtistor size 31 ar 690VAC (IEC) / 700VAC (UL)
Protistor size 31 ar SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination ar Class according to IEC
More informationNH fuse-links gtr 400VAC top indicator/live gripping-lugs size 2, 3, 4a
NH fuse-links gtr 400VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers
More informationgi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories
,, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 00, 0, 1, 2, 3 and 4 are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator or striker
More informationgg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES
, am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator
More informationProtistor size 120 gr 750VDC (IEC)
Protistor size 12 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS DC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination Very low I²t Extremely fast
More informationShort Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead
, am nh dimension knife-blade fuse-links, fuse bases, and accessories Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or
More informationHelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC
SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection
More informationFuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:
More informationSection ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES
Section ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES TECHNICAL SPECIFICATIONS L.V- HRC KNIFE (NH TYPE) FUSE-LINKS ( V.AC) HRC knife fuse-links (NH Type) must have a rated breaking capacity current of
More informationD Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES
D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES Ferraz Shawmut D fuse-links, also called Diazed type, are 500 Volts AC rated with 75kA interrupting
More informationNH DIN Dual Indication Fuse Links
Class of Operation gl/gg, 500V AC, 10 to 630 s Sizes 000 to 3 Standards/ Approvals: Description: Packaging: IEC 60269, VDE0636, DIN 43 620 1 to 4. A square bodied range of industrial fuse links for a wide
More informationHelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC
SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection
More informationHHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear
HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgears Introduction Medium voltage fuse-links according to British Standard are back-up fuse-links for the protection of substations up
More informationNH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series
Description: A range of Class am square bodied industrial fuse links for a wide variety of motor protection applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhm(size)b-690 am
More informationFuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4
URB Fuses for Semiconductor Protection European Standard Sizes 000 and 00 Class: ar Voltage ratings: AC 660 V AC 1000 V Current ratings: 16 A to 400 A Approvals: Standards: DIN 43653 IEC 60269-1 and -4
More informationSemiconductor Fuses European Fuses
66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos
More informationonlinecomponents.com
66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current
More informationSemiconductor (AC) fuses
Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN
More informationNH Solid Blades 690 VAC sizes 000 to 3
NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a
More informationMedium voltage fuses Medium voltage fuses
European Fuses DIN Fuses 7.2kV - 36kV IBD 7.2 UP TO 36 KV HIGH-VOLTAGE FUSES DESIGNED FOR POWER TRANSFORMER PROTECTION INTERIOR/EXTERIOR USE CERAMIC HOUSING MEDIUM CLASS TRIP-INDICATOR COMBINED WITH A
More informationHelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC
HelioProtection HP15NH3L SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH3L photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic
More informationfuse-links & fuse holders PHOTOVOLTAIC
fuse-links & fuse holders 04 gpv FOR APPLICATIONS 04 gpv FOR APPLICATIONS 05 gpv & FOR APPLICATIONS 06 PMF FUSE HOLDERS FOR APPLICATIONS 07 ST & FUSE BASES FOR APPLICATIONS FUSE HOLDERS & BASES gpv 10x38
More informationLow voltage NH knife-blade fuse-links
Low voltage NH knife-blade fuse-links NV KOMBI advantages ETI is introducing a new generation of low-voltage fuse-links from size NV00C up to NV3 with new, dual indication of fuse-link operation, called
More informationMULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole
MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple
More informationMULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole
MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed
More informationMEDIUM VOLTAGE DIN Fuse-Links
Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 24TDMEJ(amp) 24THMEJ(amp) 24TFMEJ(amp) 24TXMEJ(amp) Class of Operation: Back-up as IEC 60282-1
More informationLINOCUR Size D02 63A 230VAC/440VAC
IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuse-link, equiped with significant safety characeristics and sophisticated
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar PAGE05 gr PAGE06 gs NH ar RAPIDPLUS ar fuse links are intended to clearing short-circuits and have been designed and manufactured to have
More informationHigh voltage high-breaking capacity VV fuse-links
High fuse-links High fuse-links High high-breaking capacity VV fuse-links VV General information ET fuse-links named VV THERMO are designed to protect devices in switch-gears and other equipment (distribution
More informationApplications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders
Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE05 gr HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE06 gs NH HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS
More informationLENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES
LENRK/LESRK CLASS RK Catalog Number LENRK (. - 0A) 50 Volts AC or Less Catalog Number LESRK (.5-0A) 0 Volts AC or Less S LENRK 50V 0..5 75 0..5 5 0..5 9 50 5 0.5 50 0.. 70 0 0..5 5 0 50 7.5 90 0..5 0 50.
More informationNH DIN Dual Indication Fuse Links
Class gg/gl, 400Vac, 2 to 630 Amps, Sizes 000 to 3 Standards/Approvals IEC 60269, VDE 0636, DIN 43620 Part 1 and 3 Description A square bodied range of industrial fuse links for a wide variety of applications.
More informationMULTIFIX 60 Universal Bus Bar Carriers
MULTIFIX MULTIFIX BUS BAR SYSTEMS COMPONENTS FOR MM SYSTEMS FEATURES & BENEFITS MULTIFIX is a system for energy distribution comprising a variety of modular combinable components. The energy distribution
More informationMULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole
MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom
More informationLeadership in Circuit Protection
Leadership in Circuit Protection Bussmann is now a part of Eaton Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution for all applications. Only Eaton
More informationHigh-voltage high-breaking capacity VV fuse-links
High- high- VV fuse-links imum cold resistance power dissipation pre-arcing I t value total I t value [kv] (mm) I n [A] (ka) [mω] [W] [A s] [A s] 1 580,1 57 A 0 370 9 17,3 1 A 5 00 10 3 30 10 A 55 7 11
More informationMEDIUM VOLTAGE DIN Fuse-Links
Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 12TDLEJ(amp) 12THLEJ(amp) 12TKLEJ(amp) 12TXLEJ(amp) 12TFMSJ(amp) Class of Operation: Back-up
More informationCYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC
fuses 02 gg 04 am gg Cylindrical fuse links gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube
More informationnew NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price
NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high
More informationNH Plastic bases. NH Plastic bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW
FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC NH FUSE BASES FEATURES & BENEFITS Polyester insulating bases Silver-plated contacts High-pressure spring contacts Screw or rail mounting Multipolar bases available
More informationLeadership in Circuit Protection
Leadership in Circuit Protection Bussmann is now a part of Eaton Learn more at Eaton.com/Cooper Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution
More informationSelection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection
HHD-BPT Selection Guide HHD-BPT, DIN Style, Current-imiting,, Potential Transformer Protection Current ratings [A]; 0.5, 1, 2, 2.5, 3.15, 4, 5 E=192mm Page E=292mm Page E=367mm Page E=442mm Page E=537mm
More informationFUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS
1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS
More informationHigh-voltage high-breaking capacity VV fuse-links
High- high- VV fuse-links [A] (ka) [mω] [W] [A 2 s] [A 2 s] 12 580 4 6,1 57 4 A 20 370 9 17,3 164 6 A 25 260 10 36 340 10 A 46 55 7 161 1 530 16 A 60 37 13 250 2 270 20 A 80 30 15 430 3 750 25 A 105 25
More informationLOW VOLTAGE FUSES EUROPEAN NH KNIFE-BLADE FUSE SYSTEM
NH SIBA NH Fuse-links with top and center indicator are available in a large variety of voltage ratings, body sizes and operating classes: Sizes: 000, 00, 0, 1, 2, 3 and 4 Voltage ratings: AC 400 / 500
More informationBussmann series NH catalogue. Leadership in circuit protection
Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places
More informationMULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole
MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple
More informationLow-Peak 600V Class RK1
LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:
More informationNH HRC Fuses. IEC & British Standard Fuses NHG B
NH HRC Fuses NHG B Specifications Class: gg/ g L Description: DIN square bodied, dual indication industrial fuses. Construction: Steatite insulator, corrosionproof (aluminum) metal parts with full-contact,
More information34-SDMS-02 SPECIFICATIONS FOR
SPECIFICATIONS FOR M V & L V FUSE LINKS This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE
More informationMM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s
Basic Efficiency up to 1500 V 1-pole 3-pole SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN successfully
More informationMULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole
MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom
More informationfuses fuse holders CYLINDRICAL
fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES
More informationLPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse
LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)
More informationSelector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits
Selector guide PSC Square body fuses Size 3X 500-700VAC End Contact Terminals December 2013 Issue 2 The IXYS UK range of 700V/690V protistor fuse links provides maximum flexibility in equipment design
More informationHV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017
HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION March 2017 HV FUSE-LINKS IN THE WORLD UL STANDARD E OR R RATED: AMERICAN STANDARD DIN STANDARD: GERMAN STANDARD FR STANDARD: FRENCH STANDARD BS STANDARD: BRITISH
More informationMedium Voltage current limiting Fuse links
Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 200A 1. General information P&C Medium Voltage fuse-links named PCEF are designed
More informationMULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole
MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationLG HRC Power Fuses ISO 9001 ISO 14001
LG HRC Power Fuses ISO 900 ISO Current without Power Fuse (ka ms) Ipeak Let through Below 0.5 Cycle voltage(kv) Initiation of 3. 7. 5.5 3 arcing(degree) Ipeak(kA) Power Factor 5 5 90 5 70 9 0 7 7 7 5 5
More informationPSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES
PSC SQUARE BOY Ferraz Shawmut 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available
More informationHHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.
HHD HIGH VOLTAGE GERMAN DIN STANDARD FOR AIR & GAS INSULATED SWITCHGEARS OUTDOOR SWITCHGEARS The striker pin system is connected by means of a high resistance parallel conductor. After melting the main
More informationNH Dual NHIndicator Fuse System Fuse System
NH Dual NHIndicator Fuse System Fuse System Product Product Guide Guide NH Dual Indicator System Catalogue NH Dual Indicator Fuse System Class gg/gl - 400Vac - 2 to 60 Amps - s 000 to Part Numbers 400Vac
More informationBSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC
BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC FUSE RAILS IEC NH FUSE RAILS FEATURES & BENEFITS Installation on to Dimensions of s and cable connections are equivalent to those of MULTIVERT APPLICATIONS
More informationMedium Voltage current limiting Fuse links
Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 0A 1. General information P&C Medium Voltage fuse-links named PCEF are designed to
More informationSelect 700V/ ysuk.com. The. Current limiting. acceptance. protection of. within a single. recognised (10 38 fuses) October 2013
Select tor guide Cylindrical Fuse Links Sizes A, B & C 700V/ /690VAC, 1 100 A October 2013 Issue 1 The IXS UK range of ferrule fuse links aree fast acting fuses with superior cycling ability, available
More informationKLKD SERIES 10x38 FUSES
KLKD SERIES 0x FUSES 0 Vac/dc /0- A Fast Acting Description The KLKD fuse series is fast-acting with a high DC voltage rating. This family of Midget style fuses (0 x mm) is used in solar combiner boxes
More informationIEC Standard Back-Up Fuse-Links
3 / 7.2 kv 6 / 12 kv 10 / 17.5 kv 10 / 24 kv 20 / 36 kv Ferrule German DIN Standard Beyond our line of ANSI / IEEE current-limiting fuses, Mersen offers a full line of medium voltage fuse links according
More informationMULTIVERT 1000A Main Incomer, 690VAC
IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed
More informationClass gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series
Description: A range of Class gg/gl square bodied industrial fuse links for a variety of applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhg(size)b-690 gg/gl Fuse Size: 000 to
More informationCS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES
SERIES E-RATED/MEDIUM VOLTAGE FUSES 5kV, 8kV and 15.5kV FERRULE MOUNTED FUSES Amp-trap E-rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced
More informationPRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT
PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze
More informationNH (H.R.C) FUSES AND FUSE BASES
NH (H.R.C) FUSES AND FUSE BASES NH (H.R.C) Fuses NHC-FB (A...A) NH-FB (A...A) NH-FB (A...A) NH-FB (8A...4A) NH-FB (A...A) NH-FB (A...A) NH (H.R.C) Fuse Bases STEATIT NH-FA NH-FA NH-FA NH-FA NH-FA CONTENTS
More informationGeneral Purpose US Fuses
SMARTSPOT with Maximum circuit protection Amp-trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides
More informationDIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.
DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them
More informationGeneral Purpose IEC Fuses
Line protection fuses gl-gg IEC 60269 parts1, 3 and 3-1 DIN VDE 0636 Parts 10, 30 and 31 Dimensions are stipulated in the following regulations: DIN 49360 D Fuse-links DIN 49515 D Fuse-links DIN 49367
More informationEVpack-fuse MEV70 BATTERY PACK FUSES FEATURES & BENEFITS APPLICATIONS
EVpack-fuse MEV70 BATTERY FUSES BATTERY PACK FUSES FEATURES & BENEFITS Design for DC applications Low watt losses High cycling performance Full coverage of battery module voltage and current Ultra compact
More informationUL 508 Non-Fusible Disconnect Switches
UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.
More informationCL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES
SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as
More informationSwitch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV
Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads
More information2600 SERIES ILLUMINATED AND NON-ILLUMINATED ROCKER SWITCHES Overview
Overview 6 SERIES Electrical functions Frame type 1 ON - OFF 4 ON ON ON MOM - ON 6 ON - ON 7 MOM OFF MOM 8 ON OFF MOM 9 ON OFF ON double pole only LH LP Plain With protection guard Number of poles Special
More informationHHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.
HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After
More informationSemiconductor (AC) fuses
x38 grb - 69VAC 69V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: - rated current (or rating) I N - pre-arcing I 2 t (I 2 t p ) at ms - total operating I 2 t (I 2 tt) at
More informationUL 508 Non-Fusible Disconnect Switches
UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.
More informationFuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A
DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low
More informationMULTIVERT 250A Size 1, 690VAC
MULTIVERT 250A IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors.
More informationUtilisation category gl/gg 500VAC with combi indicator
DIN-fuse-links DIN fuse-links are used for the protection of electrical installations and equipment and are common for a wide area of applications. Standardised characteristics, technical data and dimensions
More informationAmp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...
Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. A Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive
More informationIEC Low Voltage Products Module 4
IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!
More informationSpecial Purpose Fuses
Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom
More information