LOW-VO L TAGE POWER DISTRIBUTION PRODUCTS

Size: px
Start display at page:

Download "LOW-VO L TAGE POWER DISTRIBUTION PRODUCTS"

Transcription

1 LOW-VO L TAGE POWER DISTRIBUTION PRODUCTS Low-voltage Magnetic Contactor Starters

2 662 Our Power Distribution Products are compact, easy-to-use, built with safety in mind, including the full lineup of Low-voltage. Low-voltage Mitsubishi is proud to support the future creation of electrical equipment through its Low-voltage. For more than 50 years, Mitsubishi's Low-voltage circuit breaker continued to deliver market needs. Our complete lineup, including the WS-V series built with a new breaking technology, is designed to respond to the individual market needs of the Receiving Distribution machineries. Product details P.664

3 663 MS-T/N Magnetic Contactor Starters A wide variety of lineup to meet any all dems The MS-T/N series magnetic contactors starters are eco-friendly, ready for global use, compact, easy-to-use, built with safety in mind. Compatible with many international stards highly-reliable to meet various situations from switchboards to machineries. Product details P.50

4 664 Low-voltage Low-voltage For more than 50 years, Mitsubishi s Low Voltage Circuit breakers earth leakage circuit breakers continued to deliver market needs. Our complete lineup, including the WS-V series built with a new breaking technology, is designed to respond to the individual market needs of the receiving distribution machineries. Circuit Circuit Motor Protection Circuit breaker for protection against overload short circuit Circuit breaker for protection against overload, short circuit, electrification P.672 P.716 P.760 P.62 P.716 P.00 P.6 Circuit breaker for protection of motor against short circuit Circuit Miniature Circuit breaker compliant with UL 49 America Circuit breaker with measuring display function P.69 P.716 P.1 P.693 P.716 P.32 Circuit breaker for protection against overload short circuit of branch circuit P.2 P.3

5 665 Residual Current Circuit Isolating Switch Circuit Protectors Circuit breaker for protection against earth leakage electrification of branch circuit Mechanical switch for equipment Circuit breaker for protection against overload of equipment P.4 P.41 P.3 P.43 P.6 P.9 P.44 Low Voltage Air Related Components Main circuit breaker to meet dems more advanced multi-functional facilities P.710 P.710 P.712 Our lineup also includes an earth leakage relay

6 666 Low-voltage Product Line-up Classification Motor Protection Frame (A) NF-C Economy class NF-S Stard class NF-H/L High-performance class NF30-CS NF63-CV NF125-CV NF250-CV NF32-SV NF-R/U Ultra current-limiting class NV-C Economy class NV-S NV32-SV Stard class NV-H/R High-performance class NF-MB NF32-SV (*1) NF63-SV NF63-HV NF125-SV NF125-SGV NF125-SEV NF125-HV NF125-LGV NF125-HEV NF125-HGV NF125-RGV NF125-UV NF160-SGV NF160-LGV NF160-HGV NF250-SV NF250-SGV NF250-SEV NF250-HV NF250-LGV NF250-HEV NF250-HGV NF250-RGV NF250-UV NV63-CV NV125-CV NV250-CV NV63-SV NV63-HV NF63-CV (*1) NF63-SV (*1) NV125-SV NV125-SEV NV125-HV NV125-HEV NV250-SV NV250-SEV NV250-HV NV250-HEV NF125-SV (*1) NF250-SV (*1) MCCB ELCB NF50-SVFU NV50-SVFU NF-CVFU NF125-SVU NF125-HVU NV-CVFU NV125-SVU NV125-HVU NF225-CWU NF250-SVU NF250-HVU NV250-SVU NV250-HVU MDU NF250-SEV with MDU NF250-HEV with MDU Miniature Residual Current Circuit Residual Current Circuit with Overload Protection Isolating Switch BH-DN BH-D6 BH-D10 BV-D BV-DN KB-D Circuit Protectors CP30-BA CP-S Air Circuit AE-SW Related Components Relays NV-ZBA, NV-ZSA, NV-ZHA, NV-ZLA Note: *1 When placing an order, specify MB. WS-V Series (New models) BH BH-P

7 Low-Voltage Circuit P.664 Magnetic Contactor Starters P NF400-CW NF630-CW NF00-CEW NF400-SW NF400-SEW NF630-SW NF630-SEW NF00-SDW NF00-SEW NF400-HEW NF630-HEW NF00-HEW NF400-REW NF400-UEW NV400-CW NV400-SW NV400-SEW NV400-HEW NV400-REW NF630-REW NV630-CW NV630-SW NV630-SEW NV630-HEW NF00-REW NF00-UEW NV00-SEW NV00-HEW NF0-SEW NF1250-SDW NF1600-SDW NF1250-SEW NF1600-SEW NF400-SWU NF400-HWU NF630-SWU NF630-HWU NF400-SEP with MDU NF400-HEP with MDU NF630-SEP with MDU NF630-HEP with MDU NF00-SEP with MDU NF00-HEP with MDU AE630-SW AE0-SW AE1250-SW AE1600-SW AE2000-SW AE4000-SWA AE2500-SW AE3200-SW AE5000-SW AE6300-SW AE2000-SWA AE4000-SW

8 66 Low-voltage The next No.1 breaker br Mitsubishi WS-V Series The all-new World Super V Series (WS-V Series) is the result of revolutionary evolution, equipped with a new cutoff technology to enhance interrupting performance, compatible with the latest stards of various countries to deliver optimal performance according to individual needs. High-Performance Takes high-performance to the next level Adoption of the Exped ISTAC Stardization Enhanced usability based on user-friendly product design Widened the scope of internal auxiliary sharing parts Environment Eco-friendly products Adapt to RoHS directive the use of restricted substance is within the line limits stipulated by the said directive Global Full lineup to meet the fast-growing internationalization Compatible with JIS, IEC (EN), GB, UL/CSA other national stards worldwide

9 Low-Voltage Circuit P.664 Magnetic Contactor Starters P High-Performance Takes High-Performance to The Next Level Technologies based on long year experience are brought together to realize more improved performance The new circuit breaking technology Exped ISTAC has improved the current-limiting performance upgraded the overall breaking capacity. Expansion of the conductor under the stator shortens the contact parting time of the mover as compared to the conventional ISTAC structure. The current-limiting performance has been improved remarkably. (The maximum peak current value has been reduced by approx. 10%.) Example of breaking capacity improvement Previous Model NF250-SW 50kA /25kA (at 230VAC) New Model NF250-SV 5kA /5kA (at 230VAC) New circuit breaking technology (Exped ISTAC) Movable conductor Current C Increased reaction force of movable conductor Current B Breaking capacity of 5 models is 20% to 50% higher than the W & WS Series Improvement of breaking capacity on 250AF-C/S/H models (Fixed) & AF-R models (Thermal/Adjustable). Grid Reaction circuit Arc Current Fixed conductor Breaking capacity comparison with a conventional model 250-RG 20% UP Model Name 250-H 250-S 250-C 3.% UP 20% UP 50% UP WS-V Series WS Series 125-RG 20% UP ka at 400VAC lcu The new electronic circuit breakers (with display) MDU breakers can display various measurement items This will enable energy management through visualization, which leads to energy saving. The display is on the circuit breaker body shows circuit information. setting can be done on the display. The display turns red during alarms. Display Current Alarm in each phase Electronic Circuit (with display) Display Unit Intelligent Communications through CC-Link data can be transmitted to Personal Computer through CC-Link. LAN(Ethernet) EcoWebServer Electronic multi-measuring instrument Energy measurement unit (EMU3 Series) Energy measurement unit (EcoMonitorPro) Air Circuit (AE-SW Series) MELSEC-Q Series programmable controller

10 6 Low-voltage Stardization Compact design for easy to use Enhanced Usability Based on User-Friendly Product Design The thermal adjustable circuit breakers electronic circuit breakers are smaller. NF250-SGW NF250-SGV (Conventional model : mm) (New model : mm) 250AF circuit breakers fixed types (NF250-CV, NF250-SV, NF250-HV, NV250-CV, NV250-SV, NV250-HV), thermal adjustable types (NF250-SGV, NF250-HGV, NF250-RGV), electronic types (NF250-SEV, NF250-HEV, NV250-SEV, NV250-HEV) are the same size, leading to the reduction stardization of panel design. Types of internal accessories are reduced from 3 types to 1 type Volume ratio 79% (Compared with our conventional models) Stardization of internal accessories contributes to the reduction of stock delivery time. Conventional models Three types For 32/63AF For 125AF For 250AF New models One type For 32 to 250AF Applicable accessories AL AX AL+AX SHT UVT 32AF 63AF circuit breakers can now be used in both AC DC circuits without specifying when ordering. This will lead to prevention of ordering mistakes. The earth leakage circuit breakers can now be equipped with a voltage shunt trip device (SHT). Innovative manufacturing using a robot-cell production line This manufacturing innovation takes the pursuit of increased productivity, shortened manufacturing lead-time improved quality to the upper limits. Individual unit production management system Robot-cell Production Line A multi-model, single-unit flow production system is utilized the ultimate multi-cycle production method. The production line is controlled using barcodes to manage the model information for each unit. Small-lot, flexible production that s one step ahead! Component Barcode Timely Resupply Manual Adjustment Work Barcode Reader

11 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Environment Eco-Friendly Products Use of Various Recyclable Materials The circuit breakers are made of thermo-plastic materials that are easy to recycle. (Some models are partially made of thermoset materials.) The major plastic parts bear material identifications so that they can be recycled. Eco-friendly products Our products are compliament with the RoHS directive the use of restricted substances is within the line limits stipulated by the said directive. Energy Saving at Mitsubishi Electric Corporation Fukuyama Works Mitsubishi Electric Corporation Fukuyama Works uses energy saving support devices such as MDU breakers EcoServer to save energy through visualization of energy. Along with visualization, Fukuyama Works also installed high-efficiency equipments to further promote energy saving. Through energy saving activity, Fukuyama Works has successfully reduced its electrical power consumption rate by 27% in 2007 (compared with 1990). Global Full Lineup to Meet The Fast-Growing Internationalization Global Networks of Sales Offices Production Bases Our sales networks are designed to comfort customers internationally through the worldwide distributors. Constantly contactable distributors enable us to accommodate customer s needs for smooth supply. MITSUBISHI ELECTRIC DALIAN INDUSTRY PRODUCTS CO.,LTD Sales Office:62 branch office representative office (available in 56 countries) Production Base :1 :43 :3 MITSUBISHI ELECTRIC CORPORATION FUKUYAMA WORKS MITSUBISHI ELECTRIC LOW VOLTAGE EQUIPMENT (XIAMEN) Co., LTD

12 672 Low-Voltage Other dnf-c (Economy class) Rated short-circuit breaking capacities (ka) Frame (A) Model NF30-CS NF63-CV NF125-CV Image Rated current In (A) 3 4 (5) 6 10 (15) (60) (60) 63 Rated ambient temperture 40 C (45 C for marine use) (30) (75) Number of poles Rated insulation voltage Ui (V) V 500V 2.5/ / / /4 7.5/4 440V 2.5/ / /2.5 10/5 10/5 IEC V 1.5/ / / /2.5 10/5 10/5 AC EN V 1.5/1.5 5/5 5/5 5/5 10/5 10/5 (Icu/Ics) 30V 1.5/1.5 5/5 5/5 5/5 10/5 10/5 230V 2.5/2 (240V) 7.5/ / /7.5 30/15 30/15 200V 2.5/2 (240V) 7.5/ / /7.5 30/15 30/15 DC 250V 2.5/2.5 (*7) 2.5/2.5 (*7) 2.5/2.5 (*7) 7.5/4 (*4) 7.5/4 (*4) Rated impulse withst voltage Uimp (kv) 4 Current (*1) AC AC/DC compatible AC/DC compatible AC/DC compatible AC/DC compatible AC/DC compatible Suitability for isolation Compatible Compatible Compatible Compatible Compatible Reverse connection Possible Possible Possible Possible Possible Number of Without current 10,000 10,000 10,000 10,000 10,000 10,000 operating cycles With current (440VAC) 6,000 (AC415V) 6,000 6,000 6,000 6,000 6,000 Utilization category A A A A A A Pollution degree EMC environment condition (environment A or B) N/A N/A N/A N/A N/A N/A ca a Overall dimensions (mm) connections Cassette-type accessories External accessories c a b b c ca Mass of front-face type (kg) Front connection (F) Page dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal Solderless (BOX) terminal (SL) d d Rear (B) 716 dround stud (assembled in) dround stud dround stud dround stud dbar stud dbar stud Plug-in (PM) d d d d d Alarm switch (AL) d (*5) d (*6) d (*6) d (*6) d (*6) d(*6) Auxiliary switch (AX) d(*5) d (*6) d (*6) d (*6) d (*6) d(*6) 725 Shunt trip (SHT) d (*6) d (*6) d (*6) d (*6) d(*6) Undervoltage trip (UVT) d (*6) d (*6) d (*6) d (*6) d(*6) With lead-wire terminal block (SLT) 737 d d d d d d Pre-alarm (PAL) 739 Closed (S) d d d d d d Enclosure Dustproof (I) 753 d d d d d Waterproof (W) d d d d d Electrical operation device (NFM) 756 d d Mechanical Panel mounting d d d d d 752 interlock (MI) (*10) mounting d d d d d LC d d d d d d Hle lock HL 750 d d d d d d device HL-S d d d d d External (F) d d d d d 740 operating hle (V) d d d d d Terminal cover (TC-L, TC-S, TTC, BTC, PTC) 744 d d d d d d Rear stud (B-ST) d d d d d 71 Plug-in (PM) d d d d d IEC 35mm rail mounting adapters 759 d d d d CE marking TÜV approval Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Marine use approval (NK, LR, ABS, GL) (NK, LR, ABS) Automatic tripping device Hydraulic magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button (*2) Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 The trip action characteristics differ between AC DC for products that are compatible with both AC DC. *2 It is attached with the alarm switch. *3 In case of a current rating of A, it does not specify NK rating. *4 Use two poles for three- four-pole products. In this case, do not use the neutral pole of the four-pole products. If wired as shown on the right, three four poles can be used for up to VDC, respectively. *5 The stard lead drawing is performd laterally. Load drawing is also available. *6 The cassette type design makes it easy for customer to install. Available for installation on side below 250A frame (excluding UVT). *7 Use two poles for three- four-pole products. In this case, do not use the neutral pole of the four-pole products. Not available for use with connection as shown on the right. * Place an order of other models in conjunction with the circuit breaker. *9 Solid state relay output is option. Please specify if other output is necessary. (Stard type is thus SLT equipped). *10 Not isolation compatible, excluding 400 to 00A frame. Line Load Line Load

13 Low-Voltage Circuit P.664 Magnetic Contactor Starters P dnf-c (Economy class) NF250-CV NF400-CW NF630-CW NF00-CEW () Adjustable (*3) / 10/ 15/ 1/9 1/9 1/9 15/12 15/12 25/13 36/1 36/1 36/1 25/19 25/19 36/1 36/1 36/1 36/1 25/19 25/19 36/1 36/1 36/1 36/1 25/19 25/19 40/20 40/20 40/20 40/20 36/27 36/27 50/25 50/25 50/25 50/25 36/27 36/27 50/25 50/25 50/25 50/25 15/12 (*4) 15/12 (*4) 20/10 (*4) 20/10 (*4) 20/10 (*4) AC/DC compatible AC/DC compatible AC/DC compatible AC/DC compatible AC/DC compatible AC Compatible Compatible Compatible Compatible Compatible Compatible Possible Possible Possible Possible Possible Possible,000,000 6,000 6,000 6,000 4,000 4,000 4,000 1,000 1,000 1, A A A A A B N/A N/A N/A N/A N/A A dscrew terminal dscrew terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal d d dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud d d d d d d d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d d d d d d d d d d d(*9) d d d d d d d d d d d d d d d d d(*) d(*) d(*) d(*) d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d TÜV approval TÜV approval Self-declaration Self-declaration Self-declaration Self-declaration Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Electronic (effective value detection) Equipped Equipped Equipped Equipped Equipped Equipped Remarks: 1. Products with rated current parenthesized are produced when an order is placed. 2. Specify P-LT when using a plug-in product with a lead-wire terminal block. 3. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells. Other

14 674 Low-Voltage Other dnf-s (Stard class) Rated short-circuit breaking capacities (ka) Frame (A) Model NF32-SV NF63-SV Image Rated current In (A) 3 4 (5) (5) 6 10 (15) Rated ambient temperture 40 C (45 C for marine use) (30) (30) (60) 63 Number of poles Rated insulation voltage Ui (V) V 500V 2.5/ / / / / V 2.5/ / / / /7.5 IEC V 2.5/ / / / /7.5 AC EN V 5/5 5/5 7.5/ / /7.5 (Icu/Ics) 30V 5/5 5/5 7.5/ / / V 7.5/ /7.5 15/15 15/15 15/15 200V 7.5/ /7.5 15/15 15/15 15/15 DC 250V 2.5/2.5 (*5) 2.5/2.5 (*5) 7.5/7.5 (*5) 7.5/7.5 (*5) 7.5/7.5 (*5) Rated impulse withst voltage Uimp (kv) Current (*1) AC/DC compatible AC/DC compatible AC/DC compatible AC/DC compatible AC/DC compatible Suitability for isolation Compatible Compatible Compatible Compatible Compatible Reverse connection Possible Possible Possible Possible Possible Number of Without current 10,000 10,000 10,000 15,000 15,000 operating cycles With current (440VAC) 6,000 6,000 6,000,000,000 Utilization category A A A A A Pollution degree EMC environment condition (environment A or B) N/A N/A N/A N/A N/A Overall dimensions (mm) connections Cassette-type accessories External accessories a ca c a b b c ca Mass of front-face type (kg) Front connection (F) Page dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal Solderless (BOX) terminal (SL) Rear (B) 716 dbar stud dround stud dround stud dround stud dround stud Plug-in (PM) d d d d d Alarm switch (AL) d (*4) d (*4) d (*4) d d (*4) d d (*4) d Auxiliary switch (AX) d (*4) d (*4) d (*4) d d (*4) d d (*4) d 725 Shunt trip (SHT) d (*4) d (*4) d (*4) d d (*4) d d (*4) d Undervoltage trip (UVT) d (*4) d (*4) d (*4) d d (*4) d d (*4) d With lead-wire terminal block (SLT) 737 d d d d d d d d Pre-alarm (PAL) 739 Closed (S) d d d d d Enclosure Dustproof (I) 753 d d d d d Waterproof (W) d d d d d Electrical operation device (NFM) 756 Mechanical Panel mounting d d d d d d d d 752 interlock (MI) (*7) mounting d d d d d LC d d d d d Hle lock HL 750 d d d d d device HL-S d d d d d External (F) d d d d d 740 operating hle (V) d d d d d Terminal cover (TC-L, TC-S, TTC, BTC, PTC) 744 d d d d d d d d Rear stud (B-ST) d d d d d 71 Plug-in (PM) d d d d d d d d IEC 35mm rail mounting adapters 759 d d d d d CE marking Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Marine use approval (NK, LR, ABS, GL) Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 The trip action characteristics differ between AC DC for products that are compatible with both AC DC. *2 In case of a current rating of A, it does not specify NK rating. *3 Use two poles for three- four-pole products. In this case, do not use the neutral pole of the four-pole products. If wired as shown on the right, three four poles can be used for up to VDC, respectively. (In case of NF250-SV, three four poles can be used for up to VDC) *4 The cassette type design makes it easy for customer to install. Available for installation on side below 250A frame Line Line (excluding UVT). *5 Use two poles for three- four-pole products. In this case, do not use the neutral pole of the four-pole products. Load Load Not available for use with connection as shown on the right. *6 Place an order of other models in conjunction with the circuit breaker. *7 Not isolation compatible. excluding 400 to 00A frame.

15 Low-Voltage Circuit P.664 Magnetic Contactor Starters P dnf-s (Stard class) NF125-SV NF125-SGV NF125-SEV NF160-SGV NF250-SV (15) (30) () (60) 63 (75) (*2) / / / / / / / 1/1 1/1 30/30 30/30 30/30 30/30 30/30 25/25 25/25 36/36 36/36 36/36 36/36 36/36 30/30 30/30 36/36 36/36 36/36 36/36 36/36 30/30 30/30 36/36 36/36 36/36 36/36 36/36 30/30 30/30 36/36 36/36 36/36 36/36 36/36 50/50 50/50 5/5 5/5 5/5 5/5 5/5 50/50 50/50 5/5 5/5 5/5 5/5 5/5 40/40 (*3) 40/40 (*3) 20/20 (300V) (*3) 20/20 (300V) (*3) 20/20 (300V) (*3) 20/20 (300V) (*3) AC/DC compatible AC/DC compatible AC/DC compatible AC AC/DC compatible AC/DC compatible (*1) AC/DC compatible (*1) Compatible Compatible Compatible Compatible Compatible Compatible Compatible Possible Possible Possible Possible Possible Possible Possible 25,000 25,000 50,000 25,000 40,000 25,000 25,000 10,000 10,000 30,000 10,000 15,000 10,000 10,000 A A A A A A A N/A N/A N/A A N/A N/A N/A dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal d d d d d d d d d d dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud d d d d d d d d d d d d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration TÜV approval Self-declaration TÜV approval Self-declaration Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process (LR, ABS, GL) (LR, ABS, GL) (LR, ABS, GL) Thermal-magnetic Thermal-magnetic Thermal-magnetic Electronic (effective value detection) Thermal-magnetic Thermal-magnetic Thermal-magnetic Equipped Equipped Equipped Equipped Equipped Equipped Equipped Remarks: 1. Products with rated current parenthesized are produced when an order is placed. 2. Specify P-LT when using a plug-in product with a lead-wire terminal block. 3. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells. Other

16 676 Low-Voltage Other dnf-s (Stard class) Rated short-circuit breaking capacities (ka) Frame (A) Model NF250-SGV NF250-SEV NF400-SW NF400-SEW NF630-SW Image Rated current In (A) Adjustable Rated ambient temperture 40 C (45 C for marine use) Number of poles Rated insulation voltage Ui (V) V / / 10/10 10/10 10/10 10/10 500V 30/30 30/30 30/30 30/30 30/30 30/30 440V 36/36 36/36 42/42 42/42 42/42 42/42 IEC V 36/36 36/36 45/45 50/50 50/50 50/50 AC EN V 36/36 36/36 45/45 50/50 50/50 50/50 (Icu/Ics) 30V 36/36 36/36 50/50 50/50 50/50 50/50 230V 5/5 5/5 5/5 5/5 5/5 5/5 200V 5/5 5/5 5/5 5/5 5/5 5/5 DC 250V 20/20 (300V) (*2) 40/40 (*2) 40/40 (*2) 40/40 (*2) Rated impulse withst voltage Uimp (kv) Current AC/DC compatible AC AC/DC compatible AC AC/DC compatible AC/DC compatible Suitability for isolation Compatible Compatible Compatible Compatible Compatible Compatible Reverse connection Possible Possible Possible Possible Possible Possible Number of Without current 25,000 25,000 6,000 6,000 6,000 6,000 operating cycles With current (440VAC) 10,000 10,000 1,000 1,000 1,000 1,000 Utilization category A A A B A A Rated short time with st current Icw (ka) at 0.25s 5 Pollution degree EMC environment condition (environment A or B) N/A A N/A A N/A N/A Overall dimensions (mm) connections Cassette-type accessories External accessories a ca c a b b c ca Mass of front-face type (kg) Front connection (F) Page d dscrew terminal dscrew terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal Solderless (BOX) terminal (SL) d d d Rear (B) 716 dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud Plug-in (PM) d d d d d d d d d d d Alarm switch (AL) d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d Auxiliary switch (AX) d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d 725 Shunt trip (SHT) d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d Undervoltage trip (UVT) d (*3) d d (*3) d d d d d d d d d With lead-wire terminal block (SLT) 737 d d d d d d d d d d d Pre-alarm (PAL) 739 d d (*5) Closed (S) d d Enclosure Dustproof (I) 753 d d d d d d Waterproof (W) d d d d d d Electrical operation device (NFM) 756 d d d (*6) d (*6) d (*6) d (*6) Mechanical Panel mounting d d d d d d d d d d d 752 interlock (MI) (*7) mounting d d d d d d LC d d Hle lock HL 750 d d d d d d device HL-S d d d d d d External (F) d d d d d d 740 operating hle (V) d d d d d d Terminal cover (TC-L, TC-S, TTC, BTC, PTC) 744 d d d d d d d d d d d Rear stud (B-ST) d d d d d d d d d d d d 71 Plug-in (PM) d d d d d d d d d d d d d d IEC 35mm rail mounting adapters 759 CE marking Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Marine use approval (NK, LR, ABS, GL) (LR, ABS, GL) (LR, ABS, GL) q q q q Automatic tripping device Thermal-magnetic Electronic (effective value detection) Thermal-magnetic Electronic (effective value detection) Thermal-magnetic Thermal-magnetic Trip button Equipped Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 The trip action characteristics differ between AC DC for products that are compatible with both AC DC. *2 Use two poles for three- four-pole products. In this case, do not use the neutral pole of the four-pole products. If wired as shown on the right, three four poles can be used for up to VDC, respectively. *3 The cassette type design makes it easy for customer to install. Available for installation on side below 250A frame (excluding UVT). *4 Use two poles for three- four-pole products. In this case, do not use the neutral pole of the four-pole products. Line Line Not available for use with connection as shown on the right. *5 Solid state relay output is option. Please specify if other output is necessary. Load Load (Stard type is thus SLT equipped) AS for flush plate type, an outline differs from a stard. *6 Place an order of other models in conjunction with the circuit breaker. *7 Not isolation compatible. excluding 400 to 00A frame.

17 Low-Voltage Circuit P.664 Magnetic Contactor Starters P dnf-s (Stard class) NF630-SEW NF00-SEW NF00-SDW NF0-SEW NF1250-SEW NF1250-SDW NF1600-SEW NF1600-SDW Adjustable Adjustable Adjustable Adjustable Adjustable (0) /10 10/10 25/13 25/13 25/13 30/30 30/30 65/33 65/33 65/33 42/42 42/42 5/43 5/43 5/43 50/50 50/50 5/43 5/43 5/43 50/50 50/50 5/43 5/43 5/43 50/50 50/50 5/43 5/43 5/43 5/5 5/5 125/63 125/63 125/63 5/5 5/5 125/63 125/63 125/63 40/40 40/20 40/20 AC AC DC AC AC DC AC DC Compatible Compatible Compatible Compatible Compatible Compatible Compatible Compatible Possible Possible Possible Possible Possible Possible Possible Possible 6,000 4,000 4,000 3,000 3,000 3,000 3,000 3,000 1, B B A B B A B B at at at A A N/A A A N/A A A dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud d d d d d d d d d (*3) d d (*3) d d d d d d d d d d d (*3) d d (*3) d d d d d d d d d d d (*3) d d (*3) d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d (*5) d (*5) d (*5) d (*5) d (*5) d d d d d d d (*6) d (*6) d(*6) d (*6) d (*6) d (*6) d (*6) d (*6) d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process q q q q Electronic (effective value detection) Electronic (effective value detection) Thermal-magnetic Electronic (effective value detection) Electronic (effective value detection) Thermal-magnetic Electronic (effective value detection) magnetic Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Remarks: 1. Products with rated current parenthesized are produced when an order is placed. 2. Specify P-LT when using a plug-in product with a lead-wire terminal block. 3. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells. Other

18 67 Low-Voltage Other dnf-l / NF-H / NF-R (High-performance class) Rated short-circuit breaking capacities (ka) Frame (A) Model NF63-HV NF125-HV NF125-LGV NF125-HGV NF125-RGV Image Rated current In (A) (63) 125 Rated ambient temperture 40 C (45 C for marine use) Number of poles Rated insulation voltage Ui (V) V 2.5/ / /2.5 10/ 10/ / 10/ 500V 7.5/ / /7.5 30/23 30/23 36/36 50/3 440V 10/ 10/ 10/ 50/3 50/3 50/50 65/65 125/125 IEC V 10/ 10/ 10/ 50/3 50/3 50/50 / 150/150 AC EN V 10/ 10/ 10/ 50/3 50/3 50/50 75/75 150/150 (Icu/Ics) 30V 10/ 10/ 10/ 50/3 50/3 50/50 75/75 150/ V 25/19 25/19 25/19 /75 /75 90/90 / 150/ V 25/19 25/19 25/19 /75 /75 90/90 / 150/150 DC 250V 7.5/7.5 (*5) 7.5/7.5 (*5) 7.5/7.5 (*5) 20/20 (300V) (*2) 40/40 (300V) (*2) Rated impulse withst voltage Uimp (kv) Current AC/DC compatible (*1) AC/DC compatible (*1) AC/DC compatible (*1) AC AC AC/DC compatible AC/DC compatible AC Suitability for isolation Compatible Compatible Compatible Compatible Compatible Compatible Compatible Compatible Reverse connection Possible Possible Possible Possible Possible Possible Possible Possible Number of Without current 15,000 15,000 15,000 25,000 25,000 50,000 50,000 50,000 operating cycles With current (440VAC),000,000,000 10,000 10,000 30,000 30,000 30,000 Utilization category A A A A A A A A Pollution degree EMC environment condition (environment A or B) N/A N/A N/A N/A N/A N/A N/A N/A Overall dimensions (mm) connections Cassette-type accessories External accessories a ca c a b b c ca Mass of front-face type (kg) Front connection (F) Page dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal d d dscrew terminal Solderless (BOX) terminal (SL) d d d d d d d d Rear (B) 716 dround stud dround stud dround stud dbar stud dbar stud dbar stud dbar stud dbar stud Plug-in (PM) d d d d d d d d d d Alarm switch (AL) d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) Auxiliary switch (AX) d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) 725 Shunt trip (SHT) d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) Undervoltage trip (UVT) d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) With lead-wire terminal block (SLT) 737 d d d d d d d d d d d d d Pre-alarm (PAL) 739 Closed (S) d d d d d d Enclosure Dustproof (I) 753 d d d d d d d Waterproof (W) d d d d d d d Electrical operation device (NFM) 756 d d d d d Mechanical Panel mounting d d d d d d d d d d d d d 752 interlock (MI) (*4) mounting d d d d d d d d LC d d d d d d d d Hle lock HL 750 d d d d d d d d device HL-S d d d d d d d d External (F) d d d d d d d d 740 operating hle (V) d d d d d d d d Terminal cover (TC-L, TC-S, TTC, BTC, PTC) 744 d d d d d d d d d d d d d Rear stud (B-ST) d d d d d d d d d d d 71 Plug-in (PM) d d d d d d d d d d d d d d d IEC 35mm rail mounting adapters 759 d d d CE marking Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Marine use approval (NK, LR, ABS, GL) q q q q q (LR, ABS, GL) (LR, ABS, GL) (LR, ABS, GL) Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 The trip action characteristics differ between AC DC for products that are compatible with both AC DC. *2 Use two poles for three- four-pole products. In this case, do not use the neutral pole of the four-pole products. If wired as shown on the right, three four poles can be used for up to VDC, respectively. *3 The cassette type design makes it easy for customer to install. Available for installation on side below 250A frame (excluding UVT). *4 Not isolation compatible, excluding 400 to 00A frame. Line Line *5 Use two poles for three- four-pole products. In this case, do not use the neutral pole of the four-pole products. Not available for use with connection as shown on the right. Load Load

19 Low-Voltage Circuit P.664 Magnetic Contactor Starters P dnf-l / NF-H / NF-R (High-performance class) NF125-HEV NF160-LGV NF160-HGV NF250-HV NF250-LGV NF250-HGV NF250-RGV / / 10/ 10/ 10/ / 10/ 50/3 36/36 50/3 50/3 50/3 36/36 50/3 65/65 50/50 65/65 65/65 65/65 50/50 65/65 125/125 / 50/50 / / / 50/50 / 150/150 75/75 50/50 75/75 75/75 75/75 50/50 75/75 150/150 75/75 50/50 75/75 75/75 75/75 50/50 75/75 150/150 / 90/90 / / / 90/90 / 150/150 / 90/90 / / / 90/90 / 150/150 20/20 (300V) (*2) 40/40 (300V) (*2) 40/40 (300V) (*2) 40/40 (300V) (*2) 20/20 (300V) (*2) 40/40 (300V) (*2) AC AC/DC compatible AC/DC compatible AC/DC compatible (*1) AC/DC compatible (*1) AC/DC compatible AC/DC compatible AC Compatible Compatible Compatible Compatible Compatible Compatible Compatible Compatible Possible Possible Possible Possible Possible Possible Possible Possible 25,000 40,000 40,000 25,000 25,000 25,000 25,000 25,000 10,000 15,000 15,000 10,000 10,000 10,000 10,000 10,000 A A A A A A A A A N/A N/A N/A N/A N/A N/A N/A dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal dbusbar terminal d d d d d d d d d d d dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud d d d d d d d d d d d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d (*3) d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process (LR, ABS, GL) (LR, ABS, GL) (LR, ABS, GL) q q (LR, ABS, GL) (LR, ABS, GL) (LR, ABS, GL) Electronic (effective value detection) Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Remarks: 1. Products with rated current parenthesized are produced when an order is placed. 2. Specify P-LT when using a plug-in product with a lead-wire terminal block. 3. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells. Other

20 60 Low-Voltage Other dnf-h / NF-R (High-performance class) Rated short-circuit breaking capacities (ka) Frame (A) Model NF250-HEV NF400-HEW NF400-REW NF630-HEW NF630-REW NF00-HEW NF00-REW Image Rated current In (A) Adjustable Adjustable Adjustable Adjustable Adjustable Adjustable Rated ambient temperture 40 C (45 C for marine use) Number of poles Rated insulation voltage Ui (V) V 10/ 35/1 35/1 15/15 500V 50/3 50/50 /35 50/50 /35 50/50 /35 440V 65/65 65/65 125/63 65/65 125/63 65/65 125/63 IEC V / / 125/63 / 125/63 / 125/63 AC EN V 75/75 / 125/63 / 125/63 / 125/63 (Icu/Ics) 30V 75/75 / 125/63 / 125/63 / 125/63 230V / / 150/75 / 150/75 / 150/75 200V / / 150/75 / 150/75 / 150/75 DC 250V Rated impulse withst voltage Uimp (kv) Current AC AC AC AC AC AC AC Suitability for isolation Compatible Compatible Compatible Compatible Compatible Compatible Compatible Reverse connection Possible Possible Possible Possible Possible Possible Possible Number of Without current 25,000 6,000 6,000 6,000 6,000 4,000 4,000 operating cycles With current (440VAC) 10,000 1,000 1,000 1,000 1, Utilization category A B B B B B B Rated short time with st current Icu (ka) at 0.25s Pollution degree EMC environment condition (environment A or B) A A A A A A A Overall dimensions (mm) connections Cassette-type accessories External accessories a ca c a b b c ca Mass of front-face type (kg) Front connection (F) Page dscrew terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal Solderless (BOX) terminal (SL) d d Rear (B) 716 dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud Plug-in (PM) d d d d d d d d d d d Alarm switch (AL) d (*1) d d (*1) d d (*1) d (*1) d d (*1) d (*1) d d (*1) Auxiliary switch (AX) d (*1) d d (*1) d d (*1) d (*1) d d (*1) d (*1) d d (*1) 725 Shunt trip (SHT) d (*1) d d (*1) d d (*1) d (*1) d d (*1) d (*1) d d (*1) Undervoltage trip (UVT) d (*1) d d d d d d d d d d With lead-wire terminal block (SLT) 737 d d d d d d d d d d d Pre-alarm (PAL) 739 d d (*2) d (*2) d (*2) d (*2) d (*2) d (*2) Closed (S) Enclosure Dustproof (I) 753 d Waterproof (W) d Electrical operation device (NFM) 756 d d (*3) d (*3) d (*3) d (*3) d (*3) d (*3) Mechanical Panel mounting d d d d d d d d d d d 752 interlock (MI) (*4) mounting d d d d d d d LC d Hle lock HL 750 d d d d d d d device HL-S d d d d d d d External (F) d d d d d d d 740 operating hle (V) d d d d d d d Terminal cover (TC-L, TC-S, TTC, BTC, PTC) 744 d d d d d d d d d d Rear stud (B-ST) d d d d d d d d d d 71 Plug-in (PM) d d d d d d d d d IEC 35mm rail mounting adapters 759 CE marking Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Marine use approval (NK, LR, ABS, GL) q (LR, ABS, GL) q q q q q q Automatic tripping device Electronic (effective value detection) Electronic (effective value detection) Electronic (effective value detection) Electronic (effective value detection) Electronic (effective value detection) Electronic (effective value detection) Electronic (effective value detection) Trip button Equipped Equipped Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 The cassette type design makes it easy for customer to install. Available for installation on side below 250A frame (excluding UVT). *2 Solid state relay output is option. Please specify if other output is necessary. (Stard type is thus SLT equipped). *3 Place an order of other models in conjunction with the circuit breaker. *4 Not isolation compatible, excluding 400 to 00A frame. Line Line Load Load

21 Low-Voltage Circuit P.664 Magnetic Contactor Starters P dnf-u (Ultra current-limiting class) NF125-UV NF250-UV NF400-UEW NF00-UEW Adjustable Adjustable /10 15/15 35/35 200/ /200 1/1 1/1 200/ / / / / / / / / / / / / / / / / / / / / / / /200 AC AC AC AC Compatible Compatible Compatible Compatible Possible Possible Possible Possible 25,000 25,000 6,000 4,000 10,000 10,000 1, A A B B N/A N/A A A dscrew terminal dscrew terminal dbusbar terminal dbusbar terminal dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud d d d d (*1) d d (*1) d d (*1) d (*1) d (*1) d d (*1) d d (*1) d (*1) d (*1) d d (*1) d d (*1) d (*1) d (*1) d d (*1) d d d d d d d d (*2) d (*2) d d d (*3) d (*3) d d d d d d d d d d d d d d d d d d d d d d d d d d d Self-declaration Self-declaration Self-declaration Self-declaration q q q Thermal-magnetic Thermal-magnetic Electronic (effective value detection) Electronic (effective value detection) Equipped Equipped Equipped Equipped Remarks: 1. Products with rated current parenthesized are produced when an order is placed. 2. Specify P-LT when using a plug-in product with a lead-wire terminal block. 3. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells. Other

22 62 Low-Voltage Other dnv-c (Economy class) Harmonic Surge Ready High-speed type Time-delay type Frame (A) Model NV63-CV NV125-CV Image Rated current In (A) (5) (10) (15) (60) 63 (60) 63 (75) Rated ambient temperture 40 C (30) Number of poles Phase line (*1) 1f2W 3f3W, 1f3W, 1f2W 1f2W 3f3W, 1f3W, 1f2W 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W Rated operational voltage Ue (V) (*2) AC Rated current sensitivity (ma) 30 30,/200/500 30,/200/500 30,/200/500 30,/200/500 30,/200/ selectable selectable selectable selectable selectable Max. operating time (s) at I n at 5I n Rated current sensitivity (ma) (/200/500 selectable) (/200/500 selectable) Max. operating time (s) (*3) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) Internal non-operating (s) (or more) (0.1/0.5/1.0) (0.1/0.5/1.0) Earth leakage indication system Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Rated short-circuit breaking capacities (ka) IEC EN (Icu/Ics) AC 440V 2.5/ / /2.5 10/5 10/5 415V 2.5/ / /2.5 10/5 10/5 400V 5/5 5/5 5/5 10/5 10/5 230V 7.5/ / /7.5 30/15 30/15 200V 7.5/ / /7.5 30/15 30/15 V 7.5/ / /7.5 30/15 30/15 Rated impulse withst voltage Uimp (kv) Current AC AC AC AC AC Suitability for isolation Compatible Compatible Compatible Compatible Compatible Reverse connection (below 230VAC) Possible Possible Possible Possible Possible Number of Without current 10,000 10,000 10,000 10,000 10,000 operating cycles With current 6,000 6,000 6,000 6,000 6,000 Utilization category A A A A A Pollution degree EMC environment condition (environment A or B) A A A A A Overall dimensions (mm) connections Cassette-type accessories External accessories a ca c a b b c ca Mass of front-face type (kg) Front connection (F) Page dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal Solderless (BOX) terminal (SL) Rear (B) 716 dround stud dround stud dround stud dbar stud dbar stud Plug-in (PM) Alarm switch (AL) d (*4) d (*4) d (*4) d (*4) d (*4) Auxiliary switch (AX) d (*4) d (*4) d (*4) d (*4) d (*4) Shunt trip (SHT) 725 d (*4) d (*4) d (*4) d (*4) d (*4) Undervoltage trip (UVT) d (*4) d (*4) d (*4) d (*4) d (*4) Earth leakage alarm switch (EAL) With lead-wire terminal block (SLT) 737 d d d d d Test button module (TBM) 73 d (*5) d (*5) d (*5) d (*5) d (*5) Closed (S) Enclosure Dustproof (I) 753 Waterproof (W) Electrical operation device (NFM) 756 d d Mechanical Panel mounting d d d d d 752 interlock (MI) (*7) mounting d d d d d LC d d d d d Hle lock HL 750 d d d d d device HL-S d d d d d External (F) d d d d d 740 operating hle (V) d d d d d Terminal cover (TC-L, TC-S, TTC, BTC, PTC) 744 d d d d d Rear stud (B-ST) d d d d d 71 Plug-in (PM) IEC 35mm rail mounting adapters 759 d d d CE marking Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Marine use approval (NK, LR, ABS, GL) Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 If using a earth leakage circuit breaker as a 1-pole 2-phase device, connect the left right poles not the central pole. When wiring to singlephase 3-wire, connect the neutral line to the central pole. *2 In case of time delay type, rated voltage is VAC. *3 When the operating time are 0.45, seconds, the circuit breaker operates between seconds, between seconds between seconds respectively. *4 The cassette type design makes it easy for customer to install. Available for installation on side below 250A frame (excluding UVT). *5 Stard type is SLT equipped. *6 Place an order of other models in conjunction with the circuit breaker. *7 Not isolation compatible, excluding 400 to 630A frame. * ACV does not acquire the CCC certification.

23 Low-Voltage Circuit P.664 Magnetic Contactor Starters P dnv-c (Economy class) Harmonic Surge Ready NV250-CV NV400-CW NV630-CW (630) f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W ,/200/500 30,/200/500 (30),/200/500 selectable selectable selectable (/200/500 selectable) (/200/500 selectable) (/200/500 selectable) (/200/500 selectable) (/200/500 selectable) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) 15/12 15/12 25/13 36/1 36/1 25/19 25/19 36/1 36/1 36/1 25/19 25/19 36/1 36/1 36/1 36/27 36/27 50/25 50/25 50/25 36/27 36/27 50/25 50/25 50/25 36/27 36/27 50/ AC AC AC AC AC Compatible Compatible Compatible Compatible Compatible Possible Possible Possible Possible Possible,000,000 6,000 6,000 6,000 4,000 4,000 1,000 1,000 1,000 A A A A A A A A A A dscrew terminal dscrew terminal dbusbar terminal dbusbar terminal dbusbar terminal dbar stud dbar stud dbar stud dbar stud dbar stud d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d (*4) d d d d d d d d d (*5) d (*5) d (*5) d (*5) d (*5) d d d (*6) d (*6) d (*6) d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d TÜV approval TÜV approval Self-declaration Self-declaration Self-declaration Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Equipped Equipped Equipped Equipped Equipped Remarks: 1. Products with rated current parenthesized are produced when an order is placed. 2. Specify P-LT when using a plug-in product with a lead-wire terminal block. 3. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells. 4. Rated operational voltage Applicable circuit voltage Available voltage range -240V /110/200/220/230/240V 5-264V -440V /110/200/220/240/254/265/30/400/415/440V 5-44V V 200/220/240/254/265/30/400/415/440V 1-44V Other

24 64 Low-Voltage Other dnv-s (Stard class) Harmonic Surge Ready High-speed type Time-delay type Frame (A) Model NV32-SV NV63-SV NV125-SV NV125-SEV Image Rated current In (A) (5) 6 10 (15) (5) (10) (15) (15) (30) (32) (60) Rated ambient temperture 40 C (30) 25 (30) (60) 63 (75) 0 (*3) Number of poles Phase line (*1) 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W Rated operational voltage Ue (V) (*2) AC Rated current sensitivity (ma) 30,/200/500 30,/200/500 30,/200/500 30,/200/500 30,/200/500 30,/200/500 30,/200/500 (30),/200/500 selectable selectable selectable selectable selectable selectable selectable selectable Max. operating time (s) at I n at 5I n Rated current sensitivity (ma) (/200/500selectable) (/200/500selectable) (/200/500selectable) Max. operating time (s) (*4) (0.45/1.0/2.0selectable) (0.45/1.0/2.0selectable) (0.45/1.0/2.0selectable) Internal non-operating (s) (or more) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) Earth leakage indication system Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) 440V 5/5 5/5 7.5/ / /7.5 25/25 25/25 36/36 415V 5/5 5/5 7.5/ / /7.5 30/30 30/30 36/36 IEC V 5/5 5/5 7.5/ / /7.5 30/30 30/30 36/36 EN AC (Icu/Ics) 230V 10/10 10/10 15/15 15/15 15/15 50/50 50/50 5/5 200V 10/10 10/10 15/15 15/15 15/15 50/50 50/50 5/5 V 10/10 10/10 15/15 15/15 15/15 50/50 50/50 5/5 Rated impulse withst voltage Uimp (kv) Current AC AC AC AC AC AC AC AC Suitability for isolation Compatible Compatible Compatible Compatible Compatible Compatible Compatible Compatible Reverse connection (below 230VAC) Possible Possible Possible Possible Possible Possible Possible Possible Rated short-circuit breaking capacities (ka) Number of Without current 10,000 10,000 15,000 15,000 15,000 25,000 25,000 25,000 operating cycles With current 6,000 6,000,000,000,000 10,000 10,000 10,000 Utilization category A A A A A A A A Rated short time withst current Icu (ka) at 0.25s Pollution degree EMC environment condition (environment A or B) A A A A A A A A Overall dimensions (mm) connections Cassette-type accessories External accessories a ca c a b b c ca Mass of front-face type (kg) Front connection (F) Page dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal d Solderless (BOX) terminal (SL) Rear (B) 716 dround stud dround stud dround stud dround stud dround stud dbar stud dbar stud dbar stud Plug-in (PM) Alarm switch (AL) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d d (*5) d d (*5) d Auxiliary switch (AX) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d d (*5) d d (*5) d Shunt trip (SHT) 725 d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d d (*5) d d (*5) d Undervoltage trip (UVT) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d d (*5) d d (*5) d Earth leakage alarm switch (EAL) With lead-wire terminal block (SLT) 737 d d d d d d d d d d Test button module (TBM) 73 d (*6) d (*6) d (*6) d (*6) d (*6) d (*6) d (*6) d (*6) Closed (S) d Enclosure Dustproof (I) 753 d Waterproof (W) d Electrical operation device (NFM) 756 d d d Mechanical Panel mounting d d d d d d d d d d 752 interlock (MI) (*) mounting d d d d d d d d LC d d d d d d d d Hle lock HL 750 d d d d d d d d device HL-S d d d d d d d d External (F) d d d d d d d d 740 operating hle (V) d d d d d d d d Terminal cover (TC-L, TC-S, TTC, BTC, PTC) 744 d d d d d d d d Rear stud (B-ST) d d d d d d d d 71 Plug-in (PM) IEC 35mm rail mounting adapters 759 d d d d d CE marking Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognized Marine use approval (NK, LR, ABS, GL) Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Electronic (effective value detection) Trip button Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 If using a earth leakage cirsuit breaker as a 1-pole 2-phase device, connect the left right poles not the central pole. When wiring to singlephase 3-wire, connect the neutral line to the central pole. *2 In case of time delay type, rated voltage is VAC. *3 In case of time delay type, rated current is produced with 20 amp. or more. *4 When the operating time are 0.45, seconds, the circuit breaker operates between seconds, between seconds between seconds respectively. 3f3W, 1f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W 3f4W 3f3W, 1f2W 3f4W *5 Cassette type accessories are field mountable type. It can respend to adhesion attachment of a breaker as stard below 250A frame. (excluding UVT.) *6 Stard type is SLT equipped. *7 Place an order of other models in conjunction with the circuit breaker. * Not isolation compatible, excluding 400 to 00A frame. *9 ACV does not acquire the CCC certification.

25 Low-Voltage Circuit P.664 Magnetic Contactor Starters P dnv-s (Stard class) Harmonic Surge Ready NV250-SV NV250-SEV NV400-SW NV400-SEW NV630-SW NV630-SEW NV00-SEW Adjustable Adjustable (630) Adjustable f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W (30),/200/500 (30),/200/500 (30),/200/500 (30),/200/500 (30),/200/500 selectable selectable selectable selectable selectable (/200/500selectable) (/200/500selectable) (/200/500selectable) (/200/500selectable) (/200/500selectable) /200/500selectable /200/500selectable (/200/500selectable) /200/500selectable (0.45/1.0/2.0selectable) (0.45/1.0/2.0selectable) (0.45/1.0/2.0selectable) (0.45/1.0/2.0selectable) (0.45/1.0/2.0selectable) 0.45/1.0/2.0selectable 0.45/1.0/2.0selectable (0.45/1.0/2.0selectable) 0.45/1.0/2.0selectable (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) 0.1/0.5/ /0.5/1.0 (0.1/0.5/1.0) 0.1/0.5/1.0 Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) 36/36 36/36 36/36 42/42 42/42 42/42 42/42 42/42 42/42 36/36 36/36 36/36 45/45 50/50 50/50 50/50 50/50 50/50 36/36 36/36 36/36 45/45 50/50 50/50 50/50 50/50 50/50 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/ AC AC AC AC AC AC AC AC AC Compatible Compatible Compatible Compatible Compatible Compatible Compatible Compatible Compatible Possible Possible Possible Possible Possible Possible Possible Possible Possible 25,000 25,000 25,000 6,000 6,000 6,000 6,000 6,000 4,000 10,000 10,000 10,000 1,000 1,000 1,000 1,000 1, A A A A B A A B A A A A A A A A A A dscrew terminal dscrew terminal d dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d d d d d d d d d d d d d d d d (*6) d (*6) d (*6) d (*6) d (*6) d (*6) d (*6) d (*6) d (*6) d d d d d d d d d d d (*7) d (*7) d (*7) d (*7) d (*7) d (*7) d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d TÜV approval TÜV approval Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Recognition in process Recognition in process Recognized Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Thermal-magnetic Thermal-magnetic Electronic (effective value detection) Thermal-magnetic Electronic (effective value detection) Thermal-magnetic Thermal-magnetic Electronic (effective value detection) Electronic (effective value detection) Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Remarks: 1. Products with rated current parenthesized are produced when an order is placed. 2. Specify P-LT when using a plug-in product with a lead-wire terminal block. 3. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells. 4. Rated operational voltage Applicable circuit voltage Available voltage range -440V /110/200/220/240/254/265/30/400/415/440V 5-44V V 200/220/240/254/265/30/400/415/440V V Other

26 66 Low-Voltage Other dnv-h / NV-R (High-performance class) Harmonic Surge Ready High-speed type Time-delay type Frame (A) Model NV63-HV NV125-HV NV125-HEV NV250-HV NV250-HEV Image Rated current In (A) (15) (30) (15) (30) (60) Rated ambient temperture 40 C (60) 63 (75) 0 (*3) Number of poles Phase line (*1) 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 3f4W 1f2W 3f3W, 1f3W, 3f4W 1f2W 3f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f2W Rated operational voltage Ue (V) (*2) AC Rated current sensitivity (ma) 30,/200/500 30,/200/500 30,/200/500 30,/200/500 30,/200/500 (30),/200/500 30,/200/500 30,/200/500 (30),/200/500 selectable selectable selectable selectable selectable selectable selectable selectable selectable Max. operating time (s) at I n at 5I n Rated current sensitivity (ma) (/200/500selectable) (/200/500selectable) (/200/500selectable) (/200/500selectable) (/200/500selectable) (/200/500selectable) Max. operating time (s) (*4) (0.45/1.0/2.0selectable) (0.45/1.0/2.0selectable) (0.45/1.0/2.0selectable) (0.45/1.0/2.0selectable) (0.45/1.0/2.0selectable) (0.45/1.0/2.0selectable) Internal non-operating (s) (or more) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) Earth leakage indication system Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Rated short-circuit breaking capacities (ka) IEC EN (Icu/Ics) AC 440V 10/ 10/ 10/ 50/3 50/3 65/65 65/65 65/65 65/65 415V 10/ 10/ 10/ 50/3 50/3 / / / / 400V 10/ 10/ 10/ 50/3 50/3 75/75 75/75 75/75 75/75 230V 25/19 25/19 25/19 /75 /75 / / / / 200V 25/19 25/19 25/19 /75 /75 / / / / V 25/19 25/19 25/19 /75 /75 / / / / Rated impulse withst voltage Uimp (kv) Current AC AC AC AC AC AC AC AC AC Suitability for isolation Compatible Compatible Compatible Compatible Compatible Compatible Compatible Compatible Compatible Reverse connection (below 230VAC) Number of Without current 15,000 15,000 15,000 25,000 25,000 25,000 25,000 25,000 25,000 operating cycles With current,000,000,000 10,000 10,000 10,000 10,000 10,000 10,000 Utilization category A A A A A A A A A Rated short time withst current Icu (ka) at 0.25s Pollution degree EMC environment condition (environment A or B) A A A A A A A A A Overall dimensions (mm) connections Cassette-type accessories External accessories a ca c a b b c ca Mass of front-face type (kg) Front connection (F) Page dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal d dscrew terminal dscrew terminal d Solderless (BOX) terminal (SL) Rear (B) 716 dround stud dround stud dround stud dbar stud dbar stud dbar stud dbar stud dbar stud dbar stud Plug-in (PM) Alarm switch (AL) d (*5) d (*5) d (*5) d (*5) d d (*5) d d (*5) d d (*5) d (*5) d (*5) Auxiliary switch (AX) d (*5) d (*5) d (*5) d (*5) d d (*5) d d (*5) d d (*5) d (*5) d (*5) Shunt trip (SHT) 725 d (*5) d (*5) d (*5) d (*5) d d (*5) d d (*5) d d (*5) d (*5) d (*5) Undervoltage trip (UVT) d (*5) d (*5) d (*5) d (*5) d d (*5) d d (*5) d d (*5) d (*5) d (*5) Earth leakage alarm switch (EAL) With lead-wire terminal block (SLT) 737 d d d d d d d d d d d Test button module (TBM) 73 d (*6) d (*6) d (*6) d (*6) d (*6) d (*6) d (*6) d (*6) d (*6) Closed (S) Enclosure Dustproof (I) 753 d d Waterproof (W) d d Electrical operation device (NFM) 756 d d d d d d Mechanical Panel mounting d d d d d d d d d d d 752 interlock (MI) (*7) mounting d d d d d d d d d LC d d d d d d d d d Hle lock HL 750 d d d d d d d d d device HL-S d d d d d d d d d External (F) d d d d d d d d d 740 operating hle (V) d d d d d d d d d Terminal cover (TC-L, TC-S, TTC, BTC, PTC) 744 d d d d d d d d d Rear stud (B-ST) d d d d d d d d d 71 Plug-in (PM) IEC 35mm rail mounting adapters 759 d d d CE marking Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognized Recognition in process Recognition in process Recognized Marine use approval (NK, LR, ABS, GL) Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Electronic (effective value detection) Thermal-magnetic Thermal-magnetic Electronic (effective value detection) Trip button Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 If using a earth leakage cirsuit breaker as a 1-pole 2-phase device, connect the left right poles not the central pole. When wiring to singlephase 3-wire, connect the neutral line to the central pole. *2 In case of time delay type, rated voltage is VAC. *3 In case of time delay type, rated current is produced with 20 amp. or more. *4 When the operating time are 0.45, seconds, the circuit breaker operates between seconds, between seconds between seconds respectively. *5 Cassette type accessories are field mountable type. It can respend to adhesion attachment of a breaker as stard. (excluding UVT.) *6 Stard type is SLT equipped. *7 Not isolation compatible. * ACV does not acquire the CCC certification.

27 Low-Voltage Circuit P.664 Magnetic Contactor Starters P dnv-h / NV-R (High-performance class) Harmonic Surge Ready NV400-HEW NV400-REW NV630-HEW NV00-HEW Adjustable Adjustable Adjustable Adjustable f3W, 1f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W 3f3W, 1f3W, 1f2W (30), /200/500 selectable (30), /200/500 selectable (/200/500 selectable) (/200/500 selectable) (/200/500 selectable) (/200/500 selectable) (0.45/1.0/2.0) (0.45/1.0/2.0) (0.45/1.0/2.0) (0.45/1.0/2.0 selectable) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) 65/65 125/63 65/65 65/65 / 125/63 / / / 125/63 / / / 150/75 / / / 150/75 / / / 150/75 / / AC AC AC AC Compatible Compatible Compatible Compatible 6,000 6,000 6,000 4,000 1,000 1,000 1, B B B B A A A A dbusbar terminal dbusbar terminal dbusbar terminal dbusbar terminal dbar stud dbar stud dbar stud dbar stud d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d (*5) d d d d d d d d d (*6) d (*6) d (*6) d (*6) d d d d d d d d d (*7) d (*7) d (*7) d (*7) d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d Self-declaration Self-declaration Self-declaration Self-declaration Recognition in process Recognition in process Recognition in process Recognition in process Electronic (effective value detection) Electronic (effective value detection) Electronic (effective value detection) Electronic (effective value detection) Equipped Equipped Equipped Equipped Remarks: 1. Products with rated current parenthesized are produced when an order is placed. 2. The setting is set to 500mA delivered when not specifying the rated current sensitivity the time of time-delay type of operation to 2.0 seconds. 3. Specify FP-LT when using a flush plate product with a leadwire terminal block. 4. Specify P-LT when using a plug-in product with a lead-wire terminal block. 5. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells. 6. Rated operational voltage Applicable circuit voltage Available voltage range -440V /110/200/220/240/254/265/30/400/415/440V 5-44V V 200/220/240/254/265/30/400/415/440V V Other

28 6 Low-Voltage Motor Protection / Other dnf-mb Rated short-circuit breaking capacities (ka) Frame (A) Model NF32-SV NF63-CV NF63-SV NF125-SV NF250-SV 200/220V 400/440V 200/220V 400/440V 200/220V 400/440V 200/220V 400/440V 200/220V 400/440V 200/220V 400/440V A A A A A A kw kw kw kw kw kw kw kw kw kw kw kw Rated current In (A) Rated motor capacity (kw) Rated ambient temperture 40 C (45 C for marine use) (40) (25) (16) (12.5) Number of poles Rated insulation voltage Ui (V) V 2.5/ / / /7.5 25/25 36/36 IEC V 2.5/ / / /7.5 30/30 36/36 EN AC 400V 5/5 5/5 5/5 7.5/7.5 30/30 36/36 (Icu/Ics) 30V 5/5 5/5 5/5 7.5/7.5 30/30 36/36 230V 7.5/ / /7.5 15/15 50/50 5/5 Rated impulse withst voltage Uimp (kv) Current AC AC AC AC AC AC Suitability for isolation Compatible Compatible Compatible Compatible Compatible Compatible Reverse connection Possible Possible Possible Possible Possible Possible Number of Without current 10,000 10,000 10,000 15,000 25,000 25,000 operating cycles With current (440VAC) 6,000 6,000 6,000,000 10,000 10,000 Utilization category A A A A A A Pollution degree EMC environment condition (environment A or B) N/A N/A N/A N/A N/A N/A Overall dimensions (mm) connections Cassette-type accessories External accessories a ca c a b b c ca Mass of front-face type (kg) Front connection (F) Page dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal dscrew terminal Solderless (BOX) terminal (SL) d d Rear (B) 716 dround stud dround stud dround stud dround stud dbar stud dbar stud Plug-in (PM) d d d d d d Alarm switch (AL) d (*1) d (*1) d (*1) d (*1) d (*1) d (*1) Auxiliary switch (AX) d (*1) d (*1) d (*1) d (*1) d (*1) d (*1) 725 Shunt trip (SHT) d (*1) d (*1) d (*1) d (*1) d (*1) d (*1) Undervoltage trip (UVT) d (*1) d (*1) d (*1) d (*1) d (*1) d (*1) With lead-wire terminal block (SLT) 737 d d d d d d Closed (S) d d d d d d Enclosure Dustproof (I) 753 d d d d d d Waterproof (W) d d d d d d Electrical operation device (NFM) 756 d (*3) d (*3) Mechanical Panel mounting d d d d d d 752 interlock (MI) (*2) mounting d d d d d d LC d d d d d d Hle lock HL 750 d d d d d d device HL-S d d d d d d External (F) d d d d d d 740 operating hle (V) d d d d d d Terminal cover (TC-L, TC-S, TTC, BTC, PTC) 744 d d d d d d Rear stud (B-ST) d d d d d d 71 Plug-in (PM) d d d d d d IEC 35mm rail mounting adapters 759 d d d d CE marking Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration TÜV approval CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Marine use approval (NK, LR, ABS, GL) q q q q q q Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button Equipped Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 The cassette type design makes it easy for customer to install. Available for installation on side (excluding UVT). *2 Not isolation compatible. *3 Place an order of other models in conjunction with the circuit breaker. Please specify MB Remarks: 1. The motor circuit breakers do not have an applicable rated motor capacity. Select a motor circuit breaker based on the total load current of the motor. 2. Products with rating parenthesized are produced when an order is placed. 3. Specify P-LT when using a plug-in product with a lead wire terminal block. 4. The circuit breaker has the rated short circuit breaking capacity specified in the shaded cells.

29 Low-Voltage Circuit P.664 Magnetic Contactor Starters P d Rated short-circuit breaking capacities (ka) Frame (A) Model NF50-SVFU NF-CVFU NF125-SVU NF125-HVU Image Rated current In (A) (*4) (3) () 75 (0) (90) Rated ambient temperture 40 C (IEC 30 C) () 75 (0) (90) () 75 (0) (90) 125 Number of poles Rated AC (V) Y/ Y/347 voltage DC (V) 600Y/347V 1 1 UL 49 40V CSA C22.2 No.5-02 AC 40Y/277V 240V V DC 60V Rated insulation voltage Ui (V) IEC EN (Icu/Ics) AC DC 690V /4 /4 10/5 10/5 500V 7.5/4 1/9 1/9 25/13 25/13 440V 7.5/4 10/5 30/15 30/1550/2550/25 415V 10/5 10/5 30/15 30/1550/2550/25 400V 10/5 10/5 30/15 30/1550/2550/25 30V 10/5 10/5 30/15 30/15 50/25 50/25 230V 15/ 15/ 50/25 50/25 /50 /50 250V 60V Rated impulse withst voltage Uimp (kv) 6 Current (*1) AC AC AC AC AC AC Suitability for isolation Compatible Compatible Compatible Compatible Compatible Compatible Reverse connection Possible Possible Possible Possible Possible Utilization category A A A A A A Pollution degree EMC environment condition (environment A or B) N/A N/A N/A N/A N/A N/A Overall dimensions (mm) connections Cassette-type accessories (*2) External accessories (*2) a ca c a b b c ca Mass of front-face type (kg) Screw terminal (AMP-N) Page d d d d d d Solderless terminal (SL) d d d d d Bar (BAR) 716 d (*5) d d d d Power supply solderless load bar (SL/BAR) d (*5, 6) d (*6) d (*6) d (*6) d (*6) Alarm switch (AL) d (*7) d (*7) d (*7) d (*7) d (*7) d (*7) Auxiliary switch (AX) d (*7) d (*7) d (*7) d (*7) d (*7) d (*7) 725 Shunt trip (SHT) d (*7) d (*7) d (*7) d (*7) d (*7) d (*7) Undervoltage trip (UVT) d d (*7) d (*7) d (*7) d (*7) d (*7) With lead-wire terminal block (SLT) 737 d d d d d d Mechanical interlock (MI) 752 Hle lock (HL) d d d d d d 750 device (HL-S) d d d d d d External (F) d d d d d d 740 operating hle (V) d d d d d d Terminal Large terminal cover (TC-L) 744 d d d d d d cover Small terminal cover (TC-S) 745 (*3) (*3) (*3) (*3) (*3) (*3) IEC 35mm rail mounting adapters 759 Stard accessory Stard accessory CE marking TÜV approval TÜV approval TÜV approval TÜV approval TÜV approval TÜV approval CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Front (F) Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button Equipped Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 The trip action characteristics differ between AC DC for products that are compatible with both AC DC. *2 These accessories differ from the general CE/CCC products in specifications. Please consult us for details. *3 The stard structure conforms to IP20 (finger protection). *4 The rated ambient temperature for NF50-SVFU, NF-CVFU, NF125-SVU NF125-HVU is specified at 40 C also by IEC. *5 The circuit breakers with busbar terminals have insulation barriers. *6 Circuit breakers for power supply solderless load screw terminal (SL/AMP-N) are available. In this case, a busbar terminal is not provided on the load side. *7 These cassette type circuit breakers can be installed by the customer. They can be installed with their side faces in close contact (except NF50-SVFU UVT). Remarks: 1. Products with rated current parenthesized are produced Line when an order is placed. 2. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells. 3. The circuit breakers can be used on single-phase circuits. Load Line Other US UL Stard 49 UL File No.E Body UL File No.E1024 Canada CSA Stard C22.2 No.5

30 690 Low-Voltage Other d Rated short-circuit breaking capacities (ka) Frame (A) Model NF225-CWU NF250-SVU NF250-HVU Image Rated current In (A) (*5) Rated ambient temperture 40 C (IEC 30 C) Number of poles Rated AC (V) Y/ Y/347 voltage DC (V) 600Y/347V 1 1 UL 49 40V CSA C22.2 No.5-02 AC 40Y/277V 240V V DC 60V Rated insulation voltage Ui (V) IEC EN (Icu/Ics) AC DC 690V /4 /4 10/5 10/5 500V 10/5 25/13 25/13 36/1 36/1 440V 15/ 36/1 36/1 50/25 50/25 415V 1/9 36/1 36/1 50/25 50/25 400V 1/9 36/1 36/1 50/25 50/25 30V 1/9 36/1 36/1 50/25 50/25 230V 35/1 65/33 65/33 /50 /50 250V (*3) 10/5 60V Rated impulse withst voltage Uimp (kv) 6 Current (*1) AC/DC compatible AC AC AC AC Suitability for isolation Compatible Compatible Compatible Compatible Compatible Reverse connection Possible Possible Possible Possible Possible Utilization category A A A A A Pollution degree EMC environment condition (environment A or B) N/A N/A N/A N/A N/A Overall dimensions (mm) connections Cassette-type accessories (*2) External accessories (*2) a ca c a b b c ca Mass of front-face type (kg) Screw terminal (AMP-N) Page d d d d d Solderless terminal (SL) d d d d Bar (BAR) 716 d d d d d Power supply solderless load bar (SL/BAR) d(*) d(*) d(*) d(*) Alarm switch (AL) d d(*7) d(*7) d(*7) d(*7) Auxiliary switch (AX) d d(*7) d(*7) d(*7) d(*7) 725 Shunt trip (SHT) d d(*7) d(*7) d(*7) d(*7) Undervoltage trip (UVT) d d(*7) d(*7) d(*7) d(*7) With lead-wire terminal block (SLT) 737 d d d d d Mechanical interlock (MI) 752 d(*6) Hle lock (HL) d d d d d 750 device (HL-S) d d d d d External (F) d d d d d 740 operating hle (V) d d d d d Terminal Large terminal cover (TC-L) 744 d d d d d cover Small terminal cover (TC-S) 745 (*4) (*4) (*4) (*4) (*4) Front (F) IEC 35mm rail mounting adapters 759 CE marking TÜV approval TÜV approval TÜV approval TÜV approval TÜV approval CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 The trip action characteristics differ between AC DC for products that are compatible with both AC DC. *2 These accessories differ from the general products in specifications. Please consult us for details. *3 When using a circuit breaker, use two poles. When wired as shown right, NF225-CWU can be used at up to 400 V DC. *4 Since NF225-CWU comes with a protective cover, it has an IP20 (finger protection) structure as stard. Other models have IP20 (finger protection) structures as stard. *5 The rated ambient temperature for NF250-SVU NF250-HVU is specified at 40 C also by IEC. *6 Not isolation compatible. *7 These cassette type circuit breakers can be installed by the customer. They can be installed with their side faces in close contact (except UVT). * Circuit breakers for power supply solderless load screw terminal (SL/AMP-N) are available. In this case, a busbar terminal is not provided on the load side. Remarks: 1. Products with rated current parenthesized are produced Line when an order is placed. 2. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells. 3. The circuit breakers can be used on single-phase circuits. Load US UL Stard 49 UL File No.E Body UL File No.E1024 Canada CSA Stard C22.2 No.5 Line

31 Low-Voltage Circuit P.664 Magnetic Contactor Starters P d Rated short-circuit breaking capacities (ka) Frame (A) Model NF400-SWU NF400-HWU NF630-SWU NF630-HWU Image Rated current In (A) Rated ambient temperture 40 C Number of poles Rated AC (V) 600Y/ Y/ Y/ Y/347 voltage DC (V) 600Y/347V UL 49 40V CSA C22.2 No.5-02 AC 40Y/277V 240V V DC 60V Rated insulation voltage Ui (V) IEC EN (Icu/Ics) AC DC 690V 10/10(5/5)(*4) 15/10 10/10 15/10 500V 30/30(25/25)(*4) 42/42 30/30 42/42 440V 42/42(36/36)(*4)65/65 42/4265/65 415V 45/45(36/36)(*4)/ 45/45 / 400V 45/45(36/36)(*4)/ 45/45/ 30V 50/50(42/42)(*4)/ 50/50/ 230V 5/5(65/65)(*4)/ 5/5/ 250V 60V Rated impulse withst voltage Uimp (kv) Current AC AC AC AC Suitability for isolation Compatible Compatible Compatible Compatible Reverse connection Possible Possible Possible Possible Utilization category A A A A Pollution degree EMC environment condition (environment A or B) N/A N/A N/A N/A Overall dimensions (mm) connections Cassette-type accessories External accessories ca a a c b b c ca Mass of front-face type (kg) Screw terminal (AMP-N) Page Solderless terminal (SL) d d(*7) Bar (BAR) 716 d(*5) d(*5) d(*5) d(*5) Power supply solderless load bar (SL/BAR) d(*5) d(*5) Alarm switch (AL) d(*3) d(*3) d(*3) d(*3) Auxiliary switch (AX) d(*3) d(*3) d(*3) d(*3) 725 Shunt trip (SHT) d(*3) d(*3) d(*3) d(*3) Undervoltage trip (UVT) d d d d With lead-wire terminal block (SLT) 737 d d d d Mechanical interlock (MI) 752 d(*1)(*2) d(*1)(*2) d(*1)(*2) d(*1)(*2) Hle lock (HL) d(*6) d(*6) d(*6) d(*6) 750 device (HL-S) External (F) d d d d 740 operating hle (V) d d d d Terminal Large terminal cover (TC-L) 744 d d d d cover Small terminal cover (TC-S) 745 Front (F) IEC 35mm rail mounting adapters 759 CE marking TÜV approval TÜV approval TÜV approval TÜV approval CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 Not isolation compatible. *2 Not acquire the TÜV certification. *3 Cassette type accessories are field mountable type. It can respend to adhesion attachment of a breaker as stard below 250A frame. (excluding UVT.) *4 The values in parentheses apply to the circuit breakers with solderless terminals. *5 The circuit breakers with busbar terminals have insulation barriers. *6 Please consult us. (Models which are not UL or TUV certified but can be locked in the ON OFF positions are available.) *7 Not available for 630A. Remarks: 1. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells. 2. The circuit breakers can be used on single-phase circuits. US UL Stard 49 UL File No.E Body UL File No.E1024 Canada CSA Stard C22.2 No.5 Other

32 692 Low-Voltage / Other d (Harmonic Surge Ready) Rated operational voltage AC V High-speed type Frame (A) Model NV50-SVFU NV-CVFU NV125-SVU NV125-HVU NV250-SVU NV250-HVU Image Rated current In (A) (5) (10) () (40) (40) Rated ambient temperture 40 C (0) (90) Number of poles Phase line (*1) 1f2W 3f3W, 1f2W 3f3W, 1f2W 3f3W, 1f2W 3f3W, 1f2W 3f3W, 1f2W 3f3W, 1f2W 3f3W, 1f2W 3f3W, 1f2W 3f3W, 1f2W 3f3W, 1f2W UL IEC EN , 50, /200/500 30, 50, /200/500 30, 50, /200/500 30, 50, /200/500 30, 50, /200/500 30, 50, /200/500 30, 50, /200/500 30, 50, /200/500 30, 50, /200/500 Rated current sensitivity In ma selectable selectable selectable selectable selectable selectable selectable selectable selectable Pickup current, UL % of ln 75% of ln 75% of ln 75% of ln 75% of ln 75% of ln 75% of ln 75% of ln 75% of ln 75% of ln Max. operating time (s) at 5ln (*4) Earth leakage indication system Display window Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) Rated short-circuit breaking capacities (ka) UL 49 CSA C22.2 No.5-02 IEC EN (Icu/Ics) AC AC 40V V V V 7.5/4 10/5 30/15 30/15 50/25 50/25 36/1 36/1 50/25 50/25 400V 10/5 10/5 30/15 30/15 50/25 50/25 36/1 36/1 50/25 50/25 230V 15/ 15/ 15/ 50/25 50/25 /50 /50 65/33 65/33 /50 /50 V 15/ 15/ 15/ 50/25 50/25 /50 /50 65/33 65/33 /50 /50 Rated impulse withst voltage Uimp (kv) Suitability for isolation Compatible Compatible Compatible Compatible Compatible Compatible Compatible Compatible Compatible Compatible Reverse connection (below 240VAC) Possible Possible Possible Possible Possible Possible Possible Possible Possible Utilization category A A A A A A A A A A Pollution degree EMC environment condition (environment A or B) A A A A A A A A A A Overall dimensions (mm) connections Cassette-type accessories (*2) External accessories (*2) a ca c a b b c ca Mass of front-face type (kg) Screw terminal (AMP-N) Page d d d d d d d d d d Solderless terminal (SL) d d d d d d d d d Bar (BAR) 716 d(*5) d d d d d d d d Power supply solderless load bar (SL/BAR) d(*5, *6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) d(*6) Alarm switch (AL) d(*) d(*) d(*) d(*) d(*) d(*) d(*) d(*) d(*) d(*) Auxiliary switch (AX) d(*) d(*) d(*) d(*) d(*) d(*) d(*) d(*) d(*) d(*) 725 Shunt trip (SHT) d(*) d(*) d(*) d(*) d(*) d(*) d(*) d(*) d(*) d(*) Undervoltage trip (UVT) d d(*) d(*) d(*) d(*) d(*) d(*) d(*) d(*) d(*) With lead-wire terminal block (SLT) 737 d d d d d d d d d d Test button module (TBM) 73 d(*9) d(*9) d(*9) d(*9) d(*9) d(*9) d(*9) d(*9) d(*9) Mechanical interlock (MI) 752 Hle lock (HL) d d d d d d d d d d 750 device (HL-S) d d d d d d d d d d External (F) d d d d d d d d d d 740 operating hle (V) d d d d d d d d d d Terminal Large terminal cover (TC-L) 744 d d d d d d d d d d cover Small terminal cover (TC-S) 745 d(*3) (*3) (*3) (*3) (*3) (*3) (*3) (*3) (*3) (*3) Front (F) IEC 35mm rail mounting adapters 759 Stard accessory Stard accessory CE marking TÜV approval TÜV approval TÜV approval TÜV approval TÜV approval TÜV approval TÜV approval TÜV approval TÜV approval TÜV approval CCC recognition Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 If using a earth leakage circuit breaker as a 1-pole 2-phase device, connect the left right poles not the central pole. *2 These are different from general models in specifications. Consult us for the details. *3 The stard structure conforms to IP20 (finger protection). *4 The maximum operating time is 0.1 according to UL *5 The circuit breakers with busbar terminals have insulation barriers. *6 Circuit breakers for power supply solderless load screw terminal (SL/ AMP-N) are available. In this case, a bar terminal is not provided on the load side. *7 Circuit breakers for V AC do not have obtained CCC certificate. * These cassette type accessories can be installed by the customer. They can be installed with their side faces in close contact with circuit breakers (except NV50-SVFU UVT). *9 Stard type is SLT equipped. Remarks: 1. Products with rated current parenthesized are produced when an order is placed. 2. Rated operational voltage Applicable circuit voltage Available voltage range V (UL) 120/240V V V (UL) 120/240/40V 66-52V 240V (UL) 240V V -230V (IEC) /110/200/220/230V 5-253V -240V (IEC) /110/200/220/230/240V 5-264V V (IEC) -440V (IEC) V (IEC) /110/200/220/ 230/240/254/265/ 30/400/415/440V 230/240/254/265/ 30/400/415/440V 5-44V V US UL Stard 49 UL File No.E Body UL File No.E1024 Canada CSA Stard C22.2 No.144 C22.2 No.5

33 Low-Voltage Circuit P.664 Magnetic Contactor Starters P dmdu Rated short-circuit breaking capacities (ka) Frame (A) Model NF250-SEV with MDU NF250-HEV with MDU NF400-SEP with MDU NF400-HEP with MDU NF630-SEP with MDU NF630-HEP with MDU NF00-SEP with MDU NF00-HEP with MDU Image Rated current In (A) Rated ambient temperture 40 C Adjustable A (12.5A Step) Adjustable Adjustable Adjustable Number of poles Phase line 3f3W, 1f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W 3f4W 3f3W, 1f3W, 1f2W 3f4W Rated insulation voltage Ui (V) IEC (Icu/Ics) AC 690V / 10/ 10/10 10/10 10/10 15/15 10/10 15/15 500V 1/1 30/23 30/30 50/50 30/30 50/50 30/30 50/50 440V 36/36 50/50 42/42 65/65 42/42 65/65 42/42 65/65 415V 36/36 / 45/45 / 45/45 / 45/45 / 400V 36/36 75/75 45/45 / 45/45 / 45/45 / 30V 36/36 75/75 45/45 / 45/45 / 45/45 / 230V 5/5 / 5/5 / 5/5 / 5/5 / 200V 5/5 / 5/5 / 5/5 / 5/5 / V Rated impulse withst voltage Uimp (kv) Current AC AC AC AC Suitability for isolation Compatible Compatible Compatible Compatible Reverse connection (below 240VAC) Number of Without current 25,000 6,000 6,000 4,000 operating cycles With current 10,000 1,000 1, Utilization category A B B B Pollution degree EMC environment condition (environment A or B) A A A A c a ca a b b c ca Mass of front-face type ( mounting) (kg) Overall dimensions (mm) connections Cassette-type accessories External accessories (*2) MDU installation mounting, Panel mounting (*1) mounting, Panel mounting (*2) Front (F) Page d d d d d d d Rear (*3) (B) d d d d d d d 716 Plug-in (PM) Alarm switch (AL) d(*4) d d(*4) d d(*4) d(*4) d(*4) Auxiliary switch (AX) d(*4) d d(*4) d d(*4) d(*4) d(*4) Shunt trip (SHT) 725 d(*4) d d(*4) d d(*4) d(*4) d(*4) Undervoltage trip (UVT) d(*4) d d(*4) d d d d MDU transform AL, AX, AL + AX (MG) d(*4) d d(*4) d d(*4) d(*4) d(*4) With lead-wire terminal block (SLT) 737 d d d d d d d Alarm contact Pre-alarm (PAL) d PAL 1a d PAL 1a d PAL 1a d PAL 1a 739 output (*5) Trip-indicator (TI) d PAL 1a, OAL 1a d PAL 1a, OAL 1a d PAL 1a, OAL 1a Electrical operation device (*6) (NFM) 756 Available only for the MDU panel mounting type Available only for the MDU panel mounting type. Disavailable alarm contact output. Mechanical Panel mounting d d d d 752 interlock (MI) (*7) mounting d(*9) d(*9) Available only for the MDU panel mounting type LC d Hle lock HL 750 d d d d device HL-S Available only for the MDU panel mounting type External (F) Available only for the MDU panel mounting type 740 operating hle (V) Available only for the MDU panel mounting type TC-L d(*) d d(*) d Available only for the MDU panel mounting type Terminal TC-S d(*) d d(*) d 744 cover TTC d(*) d(*) d(*) d(*) d(*) BTC d(*) d d(*) d Available only for the MDU panel mounting type line side Rear stud (B-ST) 71 d d(*) d d Automatic tripping device Electronic (effective value detection) Electronic (effective value detection) Electronic (effective value detection) Electronic (effective value detection) MDU measurement specifications See. 36 Trip button Equipped Equipped Equipped Equipped Page of dimensions Notes: *1 In the case of panel mounting, the panel holder plate, the screws the MDU connection cable (2m) are packed as stard. The MDU connection cable of 0.5m, 3m, 5m 10m can be specified when ordering. And dimension of the front panel drilling of the breaker is different between breaker mounting panel mounting. *2 In the case of panel mounting, the panel holder plate, the nuts the MDU connection cable (2m) are packed as stard. The MDU connection cable of 0.5m, 3m, 5m 10m can be specified when ordering. *3 For 250AF breakers, the studs are packed as stard. For 400/630/00AF breakers, please specify the installation angle of the studs because it is installed to the breaker before shipping. *4 It can be installed to the breaker by each customer. *5 In the case of the breaker with alarm contact output, the module (terminal) is attached to the right side of the breaker the control power (AC/DC -240V 50-60Hz 5VA) is needed. The Output function for alarm output of PAL can set Self-holding or Auto-reset. Default setup is Auto-reset. *6 For 250AF of electrical operation device, AL is used for the trip indication as stard. The breaker with alarm output contact is not available. *7 Not isolation compatible. * In the case of breaker mounting, the terminal cover is special type for MDU breaker. *9 Available only for the MDU panel mounting type. Other

34 694 Low-Voltage ( with ) dthree major features of 1. Saving of space labor for installation 2. Improved diversified functions 3. Provision of total cost advantages with built-in VT CT realize measurement, display transmission of electric circuit information in small space with less installation wiring work provide total cost advantages. The full of functions in small bodies are suitable for monitoring protection of electric circuits maintenance of equipment. A wide variety of models applicable to various networks supports the customers energy saving activities through detailed energy control as energy saving supporting devices. dsimply realizing measurement monitoring of electric circuits for supporting various types of energy saving control The circuit breakers measure display the load current, line voltage, electric power, electric energy, harmonic current, leak current power factor to realize detailed energy control. They support customers energy saving control. WS-V Series Applicable models NF250-SEV with MDU, NF250-HEV with MDU dthe measuring display unit can be installed on the body or panel. Examples of installation of measuring display unit mounting Panel mounting Other Model list Model type CC-Link communication Electric energy pulse output No transmission Model list Type name MDU-DP-C MDU-DP-P MDU-DP-N Applicable models NF400-SEP with MDU, NF400-HEP with MDU, NF630-SEP with MDU, NF630-HEP with MDU, NF00-SEP with MDU, NF00-HEP with MDU Note: The size of holes in the face board of the circuit breaker body varies depending on whether the measuring display unit is installed on the body or the panel. cable list Type name Cable length MDU-DP-CB-2M 2m MDU-DP-CB-3M 3m MDU-DP-CB-5M 5m MDU-DP-CB-10M 10m W & WS Series dthe measuring display unit can be installed on the body or panel. Examples of installation of measuring display unit mounting Panel mounting Model type CC-Link communication Electric energy pulse output No transmission Type name MDU-AC MDU-AP MDU-AN Remarks The model names do not include. When installing the on the body, specify the A frame type in. For example, when the circuit breaker NF400-SEP with MDU the with CC-Link communication are combined, the model name is MDU-AC400. If 630A frame or 00A frame is used, specify 630 or 00 in. When installing the on the panel, specify the cable length (0.5 m, 2 m, 3 m, 5 m or 10 m) in. For example, when the with CC-Link communication is installed on the panel with a 3-m cable, the model name is MDU-AC-PANEL 3M.

35 Low-Voltage Circuit P.664 Magnetic Contactor Starters P d for (1) The measurement display items vary depending on the model or frame A. (For the measurement accuracy, please refer to page 697.) Table 1 Model Display Storage With CC-Link communication Measurement memory items (accuracy) (*1) (*2) (*3) Communication Each phase d d Present value General (average value) (*5) d d Load current (±1.0%) Line voltage (±1.0%) Harmonic current (±2.5%) Electric power (±1.5%) Reactive power (±2.5%) Electric energy (±2.0%) (*7) Reactive energy (±3.0%) (*7) Phase with max. value d Present value of Each phase d d dem (*4) Phase with max. value d d Max. dem value among all phases d d d Time of occurrence of max. dem value among all phases d d d Present value Between each lines d d General (average value) (*5) d d Max. value among all lines d d d Time of occurrence of max. value among all lines d d d Fundamental wave of each phase d d Present value Each order of each phase d d General of each phase (*6) d d Max. value of fundamental wave among all phases d d d Time of occurrence of max. value of fundamental wave among all phases d d Max. value in each order of each phase d d d Time of occurrence of max. value in each order of each phase d d d General of each phase (*6) d d Dem value (*4) General max. value among all phases d d d Time of occurrence of general max. value among all phases d d d General distortion factor of each phase d Content in each order of each phase d Present value d d Present value d d Dem value (*4) Max. value d d d Time of occurrence of max. value d d d Present value d d Present value d d Dem value (*4) Max. value d d d Time of occurrence of max. value d d d Integrated value d d d Amount for last 1 hour d d Max. value of amount for 1 hour d d d Time of occurrence of max. value of amount for 1 hour d d d Integrated value d d d Amount for last 1 hour d d Max. value of amount for 1 hour d d d Time of occurrence of max. value of amount for 1 hour d d d Applicable models NF250-SEV with MDU, NF250-HEV with MDU Remarks Value accumulated from previous reset to present Value accumulated from previous reset to present Fault current (accuracy: ±15%) d d d Cause of fault (*) Information on fault after previous reset or last fault, cause of fault Cause of fault d d d (continuously monitored) Present value d d Power factor (±5.0%) Max. value d d d Time of occurrence of max. value d d Frequency (±2.5%) Present value d d Alarm of circuit breaker (*9) State of circuit breaker Default settings Notes: PAL, OVER, IDM_AL, ILA_AL, IUB_AL d d The PAL functions are enabled when the MDU breaker with PAL module (option) is used. Neutral line open phase alarm d The neutral line open phase alarm is given only on the display. Tripping state of circuit breaker (AL) d On installation of alarm switch for transmission with (option) ON/OFF state of circuit breaker (AX) d On installation of auxiliary switch for transmission with (option) Number of times of tripping of circuit breaker d d On installation of alarm switch for transmission with (option) Number of times of opening closing of circuit breaker d d On installation of auxiliary switch for transmission with (option) Time setting d d d Initial setting resetting after power failure are necessary (no power failure compensation) Dem time limit setting (*4) d d d By default, the dem time limit is 2 min. It can be set in the range from 0 to 15 min in 1-min steps. IDM_AL (current dem alarm) d d d By default, the function is off. The parameters can be set in the following ranges. Function: ON/OFF Pickup current: 50 to % (1% step) Dem time limit: 1 to 10 min (1-min step), 15, 20, min ILA_AL (current open phase alarm) d d d IUB_AL (unbalanced current alarm) d d d Neutral line open phase alarm d d d By default, the function is off. The parameters can be set in the following ranges. Function: ON/OFF Pickup current: 10%, fixed (no setting) Operating time: 30 sec (no setting) By default, the function is off. The parameters can be set in the following ranges. Function: ON/OFF Pickup current: 30%, fixed (no setting) Operating time: 30 sec (no setting) 30 When the single-phase 3-wire type is set, the function is turned on. Rated operating overvoltage: 135 V AC (no setting) Operating time: 1 sec (no setting) Phase switching setting d d d Default: No phase switching Alarm retention (self-retention or automatic reset) setting d d d Default: Automatic reset Phase wire type d d d Default: 3-phase 3-wire Electric energy arbitrary setting d d d Reactive energy arbitrary setting d d d Display direction d d d Default: Vertical One of vertical, horizontal 1 horizontal 2 can be selected. *1 The term each phase used for load current harmonic current refers to phase 1, 2, 3 or N. However, the phase N is provided only on circuit breakers. The term between each phase used for line voltage refers to between phases 1 2, 2 3, 3 1, 1 N, 2 N or 3 N. However, voltage between phases 1 N, 2 N 3 N is applicable only on circuit breakers. These circuit breakers measure the values every 0.25 sec. Therefore, even when a low order circuit breaker operates, operating current may not be measured. *2 Each maximum value is the largest value among values obtained from the start of operation (after the previous reset) to the present. *3 The integrated value of electric energy the integrated value of reactive energy are stored upon occurrence of power failure every 30 minutes, the fault current the cause are stored upon occurrence of fault, the set values are stored when they are set, other values are stored every 30 minutes in the nonvolatile E 2 PROM. *4 The dem time limit cannot be set individually. It is common to the items. *5 The average values of load current line voltage are calculated as shown below when the phase wire type is specified. Phase wire type Average present value of current Average present value of voltage Single-phase 2-wire Average present value of current = phase 3 current Average present value of voltage = voltage between phases 2 Single-phase 3-wire Average present value of current = (phase 1 current + Average present value of voltage = (voltage between phases phase 3 current)/2 voltage between phases 2 3)/2 3-phase 3-wire Average present value of current = (phase 1 current + Average present value of voltage = (voltage between phases phase 4-wire phase 2 current + phase 3 current)/3 voltage between phases voltage between phases 3 1 phases)/3 *6 Sum of values of harmonic components in third to 19th orders except fundamental wave component *7 The reverse power is not measured. * If the upper limit of the fault current measurement range (rated current 125 to 250 A (adjustable): 4000 A, rated current 50, 60, 75,, 125 A (fixed): 2000 A)) is exceeded when overload or short circuit fault occurs, the cause of the fault may not be displayed, the fault current may not be measured. For fault current, display of cause of fault measurement of fault current are enabled when the AL for transmission with the (option) is installed. *9 When the alarm retention mode has been set to Automatic reset, the alarm display on the will be reset automatically. When the alarm retention mode is Self-retention, the alarm display will be self-retained. In the self-retention mode, the display can be reset through the alarm reset operation (collective reset). OVER will be automatically reset regardless of the mode setting. Other

36 696 Low-Voltage Other d for (1) The measurement display items vary depending on the model or frame A. (For the measurement accuracy, please refer to page 69.) Table 2 Measurement memory items (accuracy) (*3) Load current (±2.5%) Line voltage (±2.5%) Harmonic current (±2.5%) Electric power (±2.5%) Electric energy (±2.5%) Cause of fault Power factor (±5%) Alarm of circuit breaker State of circuit breaker Default settings Notes: *1 *2 *3 *4 *5 *6 *7 * *9 *10 *11 Model Present value of each phase Dem value of each phase Average present value (*11) Max. dem value (general value) (*4) Time of occurrence of max. value (year, month, day, hour, minute) Present value between each phases Average present value (*11) Max. value (general value) (*4) Time of occurrence of max. value (year, month, day, hour, minute) Current value in 3rd, 5th, 7th 19th orders of each phase Max. value in 3rd, 5th, 7th 19th orders (general value) (*4) Time of occurrence of max. value (year, month, day, hour, minute) Current value of general harmonics of each phase (*10) Dem value of general harmonics of each phase (*10) Max. dem value (general value) (*4) Time of occurrence of max. value (year, month, day, hour, minute) Electric energy (integrated value) (*5) Electric energy per time (*5) Max. value of electric energy per time (*5) Time of occurrence of max. value (year, month, day, hour, minute) Fault current (accuracy: ±15%) (*11) Present value PAL, OVER (*6) (*11) Time setting Dem time limit setting (*7) MDU Display Electric energy Storage with pulse output (*1) Pulse output (*1) With CC-Link communication Communication Remarks The electric energy (integrated value) is stored upon occurrence of power failure every 2 hours, the fault current the cause are stored upon occurrence of fault, the dem time limit, EPAL sensitivity current, PAL pickup current, pulse unit, alarm retention phase switching settings are stored when they are set, other values are stored every 2 hours in the nonvolatile E 2 PROM. Each maximum value is the largest value among values obtained from the start of operation (after the previous reset) to the present. Every time the electric energy is integrated in the pulse unit (the unit can be set to 1 kwh, 10 kwh, kwh, 0 kwh or 00 kwh), a pulse is output. Counting can be performed with a PLC. The term each phase used for load current harmonic current refers to phase 1, 2, 3 or N. However, the phase N is provided only on circuit breakers. The term between each phase used for line voltage refers to between phases 1 2, 2 3, 3 1, 1 N, 2 N or 3 N. However, voltage between phases 1 N, 2 N 3 N is applicable only on circuit breakers. The electric energy data is 6-digit data of up to kwh. The voltage harmonic current are 3-digit data, others are 4-digit. These circuit breakers measure the values every 0.25 sec. Therefore, even when a low order circuit breaker operates, operating current may not be measured. Each general value indicates the value only of the phase with the maximum value. The electric energy is not measured in the case of reverse power flow. When the alarm retention mode has been set to Automatic reset, the PAL alarm LED display on the front panel will be reset automatically. When the alarm retention mode is Self-retention, the alarm display will be self-retained. In the self-retention mode, the display can be reset through alarm reset operation (collective reset). OVER will be automatically reset regardless of the mode setting. The dem time limit cannot be set individually. It is common to the items. Sum of values of harmonic components in third to 19th orders except fundamental wave component. The average present value of load current is the average value of current among phases 1, 2 3 (the current of the phase N is not included even in the case of a circuit breaker). When the circuit breaker is used on a single-phase 3-wire circuit, the calculated value is displayed. However, ignore it. The average present value of line voltage is the average value of voltages between phases 1 2, (the voltages between phases 1 N, 2 N 3 N are not included in the case of a circuit breaker). Setting at the pre-alarm current Ip (which can be set in the range from to % of the rated current In in 5% steps) on the circuit breaker body. The Display Unit does not have the setting function. The operating time of PAL is shown below. PAL Current value (also reverse power is measured) Dem value (also reverse power is measured) Max. dem value Time of occurrence of max. value (year, month, day, hour, minute) Tripping state of circuit breaker (AL) ON/OFF state of circuit breaker (AX) PAL pickup current setting * Setting on circuit breaker body The does not have the setting function. LED on When alarm switch for transmission with (option) is installed When auxiliary switch for transmission with (option) is installed Initial setting resetting after power failure are necessary (no power failure compensation). Default: 2 min Setting in 1-min steps in range from 0 to 15 min Default: % Setting in 5% steps in range from to % Default setting on breaker body is % unless otherwise specified. Default: 1 kwh/pulse Pulse unit setting Setting to 1 kwh, 10 kwh, kwh, 0 kwh or 00 kwh Phase switching setting Default: No phase switching Alarm retention (self-retention or automatic reset) setting Default: Automatic reset Same as pre-alarm operating time Tp on circuit breaker body Applicable models NF400-SEP with MDU, NF400-HEP with MDU, NF630-SEP with MDU, NF630-HEP with MDU, NF00-SEP with MDU, NF00-HEP with MDU Time limit: 0 to 15 min, changeable (Same as the present value when 0 min is specified) Max. dem value after previous reset Max. value after previous reset (not dem value) Max. value after previous reset (not dem value) Time limit: 0 to 15 min, changeable (Same as the present value when 0 min is specified) Max. dem value after previous reset Time limit: 0 to 15 min, changeable (Same as the present value when 0 min is specified) Max. dem value after previous reset Value accumulated from previous reset to present Amount for 1 hour from hour to hour on built-in clock Max. dem value after previous reset Information on fault after previous reset or last fault, cause of fault (continuously monitored)

37 Low-Voltage Circuit P.664 Magnetic Contactor Starters P d for (2) Table 3 Item Data updating cycle Tolerances Dem time limit setting range Voltage circuit (1f2W, 3f3W) Rated input Power failure compensation Voltage circuit (1f3W) Voltage circuit (3f4W) Current circuit Frequency (1) Wh (integrated value) (2) Max. value (3) Setting data Clock Clock accuracy External dimensions (unit: mm) Control power supply Other functions Specification 250 ms (harmonic current: 2 s) Current voltage: ±1.0% (to rating input) Electric power: ±1.5% (to rating input) Reactive power: ±2.5% (to rating input) Harmonic current: ±2.5% (to rating input) Power factor: ±5% Frequency: ±2.5% Electric energy: ±2.0% (voltage V to 440 V, range from 5 to % of current rating, power factor 1) Reactive energy: ±3.0% (voltage V to 440 V, range from 10 to % of current rating, power factor 0) Fault current: ±15% (*1) 0 to 15 min (1-min steps) 440 V (only breakers applicable to 3f4W) Load current/harmonic current: 250 A 50 Hz/60 Hz (automatic discrimination of frequency) Stored in EEPROM (nonvolatile memory) * Wh varh are stored upon occurrence of power failure every 30 min. * Max. value is stored every 30 min. Setting data are stored when they are set. No power failure compensation Approx. 1 min/month See. Compatible with to 240 V AC/DC, 50/60 Hz (allowable voltage range: 5% to 110%), 12 VA (*2) Function for switching phases to be measured to PAL alarm, self-retention/automatic reset setting function (*3) Function for counting number of times of opening closing of circuit breaker body (*4) Notes: *1 The measurement of fault current of load is enabled when the AL switch for transmission with (option) is installed in the body. *2 When the MDU unit control power is turned on, a rush current transitionally flows (maximum rush current: 2A, energizing time: 1ms (240V AC) *3 The PAL functions are enabled when the MDU breaker with PAL module (option) is used. *4 The function is enabled when the AX switch for transmission with (option) is installed in the body. dnetwork for [Electric energy pulse output] Table 4 Item Output elements Contact capacity Output pulse unit Output pulse width Max. wiring length Specification Solid state relay (SSR), no voltage a contact (Ca Cb terminals: no polarity) Compatible with 24V DC to 200 V AC, 20 ma 1, 10,, 0 00 kwh/pulse (settable) 0.35 to 0.45 s m [CC-Link communication] Table 5 Item Communication speed Communication method Synchronization method Encoding method Transmission format Number of occupied stations Number of connected units Station number CC-Link version Applicable models NF250-SEV with MDU, NF250-HEV with MDU Specification 10M/5M/2.5M/625k/156kbps Broadcast polling method Frame synchronization method NRZI Conforming to HDLC Remote device occupying 1 station Meet the following conditions. When a system consists only of s, up to 42 units can be connected. Condition 1 for number of connected units (1 a) + (2 b) + (3 c) + (4 d) q 64 a: Number of units occupying 1 station b: Number of units occupying 2 stations c: Number of units occupying 3 stations d: Number of units occupying 4 stations Condition 2 for number of connected units (16 A) + (54 B) + ( C) q 2304 A: Number of units at 1 remote I/O station q 64 B: Number of units at remote device station q 42 C: Number of units at local station q 26 Setting in range from 1 to 64 (Set the station number without fail.) CC-Link Ver.1.10 Master station Remote I/O station or remote device station Remote I/O station or remote device station Local station or intelligent device station Local station or intelligent device station Other Max. total extension cable length cable length between stations Cable length between stations Max. total extension cable length Cables applicable to CC-Link Ver (with use of 110-ohm terminal resistance) Communication speed 156kbps 625kbps 2.5Mbps 5Mbps 10Mbps Cable length between stations 0.2 m or more Max. total extension cable length 1200m 900m 400m 160m m Cables applicable to CC-Link Ver (shielded 3-core twisted pair cables) Connecting cable * Cables applicable to Ver supplied by different manufacturers can be used simultaneously. Note: For more information, visit the website of CC-Link Partner Association ( ).

38 69 Low-Voltage Other d for (2) Table 6 Item Data updating cycle Tolerances Dem time limit setting range Voltage circuit (1f2W, 3f3W) Voltage circuit (1f3W) Rated input Power failure compensation Voltage circuit (3f4W) Current circuit Frequency (1) Wh (integrated value) (2) Max. value (3) Setting data Clock Clock accuracy External dimensions (unit: mm) Control power supply Other functions Specification 250 ms (harmonic current: 2 s) Current, voltage Electric power: ±2.5% (to rating input) Power factor: ±5% Electric energy: ±2.5% (voltage V to 440 V, range from 5 to % of current rating, power factor 1) Fault current: ±15% 0 to 15 min (1-min steps) 440 V (only breakers applicable to 3f4W) Load current/harmonic current: A/225 A/400 A/600 A/00 A (Automatic discrimination. Determined based on A frame of circuit breaker. A when rated current of 225 A frame is A or less) Leakage current: 500 ma 50 Hz/60 Hz (automatic discrimination of frequency) Stored in EEPROM (nonvolatile memory) * Wh is stored upon occurrence of power failure every 2 hours * The max. value is stored every 2 hours. The setting data is stored when it is set. No power failure compensation Approx. 1 min/month W D H: Compatible with to 240 V AC/DC, 50/60 Hz (allowable voltage range: 5% to 110%), 12 VA Function for switching phases to be measured to ECA/PAL alarm, self-retention/automatic reset setting function Note: *1 When the MDU unit control power is turned on, a rush current transitionally flows (maximum rush current: 2A, energizing time: 1ms (240V AC) dnetwork for [Electric energy pulse output] Table 7 Item Output elements Contact capacity Output pulse unit Output pulse width Max. wiring length Specification Solid state relay (SSR), no voltage a contact (Ca Cb terminals: no polarity) Compatible with 24V DC to 200 V AC, 20 ma 1, 10,, 0 00 kwh/pulse (settable) 0.35 to 0.45 s m [CC-Link communication] Table Item Communication speed Communication method Synchronization method Encoding method Transmission format Number of occupied stations Number of connected units Station number CC-Link version Max. total extension cable length cable length between stations Applicable models NF400-SEP with MDU, NF400-HEP with MDU, NF630-SEP with MDU, NF630-HEP with MDU, NF00-SEP with MDU, NF00-HEP with MDU Specification 10M/5M/2.5M/625k/156kbps Broadcast polling method Frame synchronization method NRZI Conforming to HDLC Remote device occupying 1 station Meet the following conditions. When a system consists only of s, up to 42 units can be connected. Condition 1 for number of connected units (1 a) + (2 b) + (3 c) + (4 d) q 64 a: Number of units occupying 1 station b: Number of units occupying 2 stations c: Number of units occupying 3 stations d: Number of units occupying 4 stations Condition 2 for number of connected units (16 A) + (54 B) + ( C) q 2304 A: Number of units at 1 remote I/O station q 64 B: Number of units at remote device station q 42 C: Number of units at local station q 26 Setting in range from 1 to 64 (Set the station number without fail.) CC-Link Ver Master station Remote I/O station or remote device station Remote I/O station or remote device station Cable length between stations Local station or intelligent device station Local station or intelligent device station CMax. total extension cable length Cables applicable to CC-Link Ver (with use of 110-ohm terminal resistance) Communication speed 156kbps 625kbps 2.5Mbps 5Mbps 10Mbps Cable length between stations 0.2 m or more Max. total extension cable length 1200m 900m 400m 160m m When the is installed on the panel, the terminal block on the panel mounting plate the terminal block on the are connected with a CC-Link cable having a one-way length of 15 cm an entire length of 30 cm. When connecting the unit in consideration of the following three points. (1) The one-way length of the CC-Link cable, 15 cm, is included in the distance between stations. (2) The entire length of the CC-Link cable, 30 cm, is included in the maximum transmission distance (total extension distance). Cables applicable to CC-Link Ver (shielded 3-core twisted pair cables) Connecting cable * Cables applicable to Ver supplied by different manufacturers can be used simultaneously. Note: For more information, visit the website of CC-Link Partner Association (HYPERLINK ).

39 Low-Voltage Circuit P.664 Magnetic Contactor Starters P dcautions when Using (common instructions) accuracy (1) The accuracy of measurement of current or voltage is indicated as the percentage of error to the rated current or voltage for measurement by the. The measurement rated current is the maximum rated current of each ampere frame. For W & WS Series, the accuracy is the max. rated current ±2.5%. For WS-V Series, the accuracy is the max. rated current ±1%. (For example, when the rated current of NF630-SEP with is 350 A, the measurement rated current is 630 A, the current accuracy is 630 A ±2.5% = ±15 A.) * The measurement rated voltage is 440 V. (Common to all A frames) When the current is less than 1.0% of the measurement rated current in the case of WS-V Series Display Unit or less than 2.0% of the measurement rated current in the case of W & WS Series Display Unit or when the voltage is less than 5.0% of the measurement rated voltage in the case of WS-V Series or less than 2.0% of the measurement rated current in the case of W & WS Series, the current or voltage is cut off, zero is displayed. (2) When the current is cut off, the current is displayed as 0 A. However, if the current is 0.4% or more of the measurement rated current, the electric energy is measured. (3) The accuracy of power factor is the percentage to electrical angle of 90. A power factor of 50% or less is displayed as a reference value. (4) The accuracy of electric energy is ±2.0% of the true value in the case of WS-V Series ±2.5% of the true value in the case of W & WS Series in the range of measurement rated voltage ( V to 440 V) current (measurement rated current of 5 to %). How to use on single-phase 2-wire circuity (1) Connect the breaker as shown in the right figure. The phase 1 on the load side is charged. Insulate it. As measurement data, use the current of the phases 2 3 the voltage between the phases 2 3. Although the current of the phase 1 the voltage between the phases 1 2 the phases 3 1 are measured, ignore the measurements. The is designed for 3-phase 3-wire single-phase 3-wire circuits. On W & WS Series, the average values of load current line voltage are calculated from the values of the phases 1, 2 3 (between the phases). Ignore these measurement values. Also when the breaker is used on a single-phase 3-wire circuit, ignore these values. When using any WS-V Series, set the phase wire type. Phase sequence of The phase sequence of can be set by using the phase switching function as shown below. When the breaker is installed vertically with the power supply side upward (see the right figure), the phase sequence is set as stated below. No phase switching: 1, 2, 3 N from the left (default) With phase switching: 3, 2, 1, N from the left Set the phase sequence in accordance with the installation wiring methods. Notes (1) The phase N is provided only on circuit breakers. Notes (2) Note that the position of the phase N is unchanged Notes (2) regardless of the phase switching setting. Reverse connection of The cannot be connected with the power supply load sides set reversely. of in close contact The must not be installed in close contact. (1) In the case of 400, 630 or 00A frame, install the breaker body securing a wiring space of 30 mm or more on the right side of the breaker to connect the connecting cables fitting the connecting cable connectors. (2) In the case of WS-V Series display Unit, install the breaker body securing a wiring space of 40 mm or more on the right side of the breaker to connect the connecting cables. Line side Load side N No phase switching (default) Load side Busbar 1 Line side Measurement phase Phase switching setting: No phase switching on single-phase 2-wire circuit 2 3 ATTENTION: Live part Load Line side Load side *Phase N is provided only on breakers N With phase switching Line side Load side Measurement phase Phase switching setting: With phase switching Other

40 0 Low-Voltage Other dcautions when using (For ) Transmission method (1) One of No transmission, With pulse output With CC-Link communication should be specified. (2) W & WS Series with CC-Link communication cannot be manufactured for installing the on the breaker body. (3) When With transmission is selected, data which can be transmitted depends on the function of the Display Unit body. The transmission options cannot be installed or changed later. Specify the options when issuing the initial order. (4) For the maximum number of connected units transmission distance for each transmission type, see the following tables. <WS-V > Tables 4 5 <W & WS > Tables 7 of (1) When the installation of on panel has been specified, the breaker will come with the panel mounting parts, mounting screws 2-m connecting cable (stard). (The 0.5-, 3-, 5- or 10-m connecting cable can be specified.) (2) If the installation position of the is changed from the panel to the body or vice versa, the the breaker body must be returned to the manufacturer for modification. with CC-Link communication (W & WS Series ) (1) If you intend to use the circuit breaker with its pane out on the face board, specify the installation on panel. dchange of display direction for breaker mounting <WS-V Series > (1) When installing the on the breaker body installed in the horizontal direction, the direction of the display can be changed according to the installation direction. (2) The display direction is set on the display unit. Line side Load side Line side Default display direction with line side on left with line side on right <W & WS Series > (1) When installing the on the breaker body installed in the horizontal direction, the direction of the display of can be changed for ease in reading according to the installation direction. (2) Remove the screws on the rear panel of the, change the direction according to the installation direction. Display of Load side Display of Load side display mounting screws Line side with power supply side on left with power supply side on right Default direction of display

41 Low-Voltage Circuit P.664 Magnetic Contactor Starters P.50 1 MEMO Other

42 2 Low-Voltage Miniature Model BH BH-P Frame (A) Image Number of poles Rated current (A) at ambient temperature 40 C Rated voltage (V),,,, AC 230/ /400 DC Rated short circuit capacity (ka) AC230/400V 3 3 IEC AC400V 3 3 DC125V 1 1 Other Instantaneous tripping (mm) Type C (5 In <, 10 In) a b c ca Mass (kg) (*1) Automatic tripping device Optional accessories Clamp terminal Thermal, magnetic Plug-in (line) Clamp (load) Terminal cover d Mounting plate d Terminal base d Lock cover d d Approved by LR, GL, NK LR, BV, AB, GL, NK Note: a b ca c *1 If reguired solderless terminal can be supplied. (BH : Line Load side, BH-P : Load side only)

43 Low-Voltage Circuit P.664 Magnetic Contactor Starters P.50 3 Model BH-D6 BH-D10 BH-DN Image Number of poles [P] (3+N) *1 2(1+N) * (3+N) *1 2 (1+N) *1 Instantaneous tripping Type B, C, D *2 Type B, C *2 Type B, C, D *2 Type C *2 Rated insulation voltage Ui [V] Rated current In [A] at ambient temperature 30 C Rated shortcircuit capacity [ka] IEC (Icn) Number of operating cycles [mm] a b 0.5, 1, 1.6, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, , 1, 1.6, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, , 1, 1.6, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63 6, 10, 16, 20 AC 230V /400V V 6 10 Without current,000 10,000 20,000 With current,000 10,000 20,000 ca c a b 7 7 c ca Type of overcurrent release Thermal-magnetic Thermal-magnetic Thermal-magnetic Mounting IEC35mm rail IEC35mm rail IEC35mm rail Applicable wire size 1 to 25mm 2 1 to 25mm 2 1 to 10mm 2 Weight [kg] Mass Alarm switch (AL) d d optional Auxiliary switch (AX) d d accessories Shunt trip (SHT) d d Terminal connection Solderless Solderless Solderless Based on stard IEC IEC IEC CE marking EN : Self-declaration EN : Self-declaration EN : Self-declaration CCC GB GB GB Notes: *1 N pole is a switched neutral pole (without overcurrent release device). *2 Type B (3 In <, 5 In), Type C (5 In <, 10 In), Type D (10 In <, 20 In) Model Image BH-D10 (For DC) Number of poles [P] 1 2 Instantaneous tripping Type B, C *3 Rated insulation voltage Ui [V] 250 Rated current In [A] at ambient temperature 30 C Rated shortcircuit IEC capacity [ka] (Icn) Number of operating cycles [mm] Type of overcurrent release Mounting a b 0.5, 1, 1.6, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63 DC 125V V 10 Without current,000 With current 4,000 ca c a 1 36 b 7 c 44 ca Thermal-magnetic IEC35mm rail Applicable wire size 1 to 25mm 2 Weight [kg] Mass Alarm switch (AL) d optional Auxiliary switch (AX) d accessories Shunt trip (SHT) d Terminal connection Solderless Based on stard IEC CE marking EN : Self-declaration CCC GB Notes: *3 Type B: (5 In <, 7 In), Type C: (7 In <, 15 In) Other

44 4 Low-Voltage Residual Current Isolating switch Other Model Image Isolating switch Number of poles [P] (3+N) Utilization category Rated current [A] at ambient temperature 30 C KB-D AC22A class 32, 63, 0 Rated voltage [VAC] Short time withst current [A] Short-circuit making capacity [A] [mm] 20 3 In, 1s 20 3 In a b 7 c 44 ca Mass [kg] Number of operating cycles Mounting Without current 20,000 With current 3,000 IEC35mm rail Applicable wire size 1 to 25mm 2 Weight [kg] Terminal connection Solderless Based on stard IEC CE marking Model Image RCCB EN : Self-declaration CCC GB BV-D Number of poles [P] 2(1+N) *1 *1 *3 4(3+N) Rated current [A] at ambient temperature 30 C 25, 40, 63 Rated voltage [VAC] /400 Rated current sensitivity Inn [ma] 30, 300 Max. operating time at 5Inn [s] 0.04 Pulsating current sensitivity Type AC Rated conditional short-circuit current [ka] 6 [mm] a b 5 c 44 ca Mass [kg] Rated making breaking capacity Im [A] 500(In 25,40A), 630(In63A) Rated conditional short-circuit current Inc [ka] 6 Rated residual making breaking capacity Inm [A] 500(In 25,40A), 630(In63A) Rated conditional residual short-circuit current Inc [ka] 6 Number of operating cycles Without current,000 With current,000 Type of overcurrent release Mounting IEC35mm rail Applicable wire size 1 to 25mm 2 Weight [kg] Terminal connection Solderless Based on stard IEC CE marking a EN : Self-declaration CCC GB a b b ca c ca c Model Image RCBO BV-DN Number of poles [P] 2(1+N) *1 Rated current [A] at ambient temperature 30 C 6, 10, 16, 20, 25, 32, 40 Rated voltage [VAC] 230 Rated current sensitivity Inn [ma] 30,, 300 Max. operating time at 5Inn [s] 0.04 Pulsating current sensitivity Type AC Breaking capacity [ka] sym. (IEC 69) 4.5 Tripping characteristics Type C *2 [mm] a 36 b c 44 ca Mass [kg] 0.19 Automatic tripping device Number of operating cycles Thermal, magnetic Without current 20,000 With current Type of overcurrent release Mounting 20,000 (In 6,10,16,20A) 15,000 (In 25A) 10,000 (In 32,40A) Thermal-magnetic IEC35mm rail Applicable wire size 1 to 16mm 2 Weight [kg] 0.19 Terminal connection Solderless Based on stard IEC CE marking a b ca c EN : Self-declaration CCC GB Notes: *1 N pole is a switched neutral pole (without overcurrent release device). *2 Type C: (5 In <, 10 In) *3 For use to three phase 4-wire type. When using, it be sure to connect the neutral wire to the neutral phase. Not available for use to three phase 3-wire type.

45 Low-Voltage Circuit P.664 Magnetic Contactor Starters P.50 5 for Miniature Functions of Internal accessory AL Alarm switch AX Auxiliary switch SHT Shunt trip Equipping of Accessory Model BH-D6 BH-D10 AL AX SHT : Accessory equipped : Accessory not equipped Function Electrically indicates the trip status of the circuit breaker. Electrically indicates the On/Off status of the circuit breaker. Electrically trips the circuit breaker from a remote location. Permissible working voltages are to 110% of the AC rated voltage or to 125% of the DC rated voltage. BH, BH-P, BH-DN, BV-DN, KB-D, BV-D AL AX AL+AX AX+AX Type AL-05DLS AX-05DLS ALAX-05DLS AX2-05DLS Configuration 1C 1C 2C 2C Contact Contact capacity 400VAC, 2A 230VAC, 5A 120VDC, 0.4A 4VDC, 1.5A 24VDC, 4A Line AX AX Function Load AL AX AL AX Clamp terminal Compliance stard IEC SHT Type SHTA400-05DLS SHTD04-05DLS Cut-off switch Equipped Voltage VAC 24-4VDC 110VAC Input power requirement 230VAC 400VAC 60VA 250VA 750VA Operating time [ms] <20 Solderless terminal Compliance stard IEC VDC 75VA 4VDC 300VA Other * Secure a sufficient input power supply so that the voltage will not drop below the permissible lower working voltage (% of the lowest rated voltage). * The operating time denotes the time from when the rated voltage is applied to SHT until the time the main contact of the breaker starts to open.

46 6 Low-Voltage Circuit Protectors Combinations of AL AX 2AX ALAX Accessory SHT connection combinations AX+SHT AL+SHT 2AX+SHT ALAX+SHT Other AL AX AL+AX AX+AX SHT Outline Drawing 9 45 M3.5 screw AL-05DLS AX-05DLS ALAX-05DLS AX2-05DLS 17 max AL-05DLS M3.5 screw of Line Load Side Line 17 max AX-05DLS Line 95 ALc AL 96 ALb ALa Load Load 44 AX AXc 12 AXb 14 AXa Type ALAX-05DLS 9 45 M3.5 screw max ALAX-05DLS Line Load 95 AX AL AXc 12 AXb 14 AXa 95 ALc 96 ALb 9 ALa 1 45 M5 screw SHTA400-05DLS SHTD04-05DLS AX2-05DLS Line Load max AX AX Solderless terminal 11 AXc 12 AXb 14 AXa 21 AXc 22 AXb 24 AXa of (AX, AL, SHT) (1) (2) Removal 1 Off 2 Hook 3 Insert 1 4 Click 2

47 Low-Voltage Circuit P.664 Magnetic Contactor Starters P.50 7 Circuit Protectors Frame (A) 30 Model CP30-BA CP-S Image Number of poles Rated insulation voltage Ui (V) Rated impulse withst voltage Uimp (kv) Rated current (A) AC (V) Rated voltage (V) UL 1077 DC (V) CSA C22.2 No.235 (*11) AC 2.5kA at 250V 1.5kA at 250V DC 2.5kA at 65V 2.5kA at 125V 1kA at 65V Rated insulation voltage Ui (V) Rated short-circuit 1.5kA at 230V capacity (ka) AC kA at 120V IEC EN (Icn) EN IEC (Icu/Ics) DC 2.5kA at 60V 2.5kA at 120V 1kA at 60V 1kA at 120V (1kA at 60V) (*7) Rated insulation voltage Ui (V) 250 AC 2.5/2.5kA at 230V DC 2.5/2.5kA at 60V 2.5/2.5kA at 120V AC-DC common use d (*1) (*) Reverse connection d Rated short time current (for switch only type) 1kA at 60V AC250V 50/60Hz 1500A 0.02s AC125V 50/60Hz 2500A 0.02s DC65V 0A 0.02s DC125V 0A 0.02s Rated ambient temperature ( C) 40 (T40) 25 (T25) Operating characteristics Mode of tripping Instantaneous type (I); Medium type (M), (MD); Slow type (S), (SD); Fast type (F) (*2) Instantaneous type (I): magnetic only [MO] Medium type (M), (MD) Slow type (S), (SD) : hydraulic-magnetic [HM] Fast type (F) Instantaneous type (I); Medium type (M), (MD); Slow type (S), (SD); Fast type (F) (FD) Instantaneous type (I): magnetic only [MO] Medium type (M), (MD) Slow type (S), (SD) : hydraulic-magnetic [HM] Fast type (F), (FD) Method of operation S-type (IEC 60934) Trip-free behaviour Trip-free (IEC 60934) Mass (kg) Retractable small terminal cover (TC-S) dstard IP20 (front, terminal covers closed) [Certified of TUV] Inertial delay (ID) d (Medium, Slow type: AC only) d (Medium, Slow, Fast type: AC only) Alarm switch (AL) d (1c) d (1c) (*7) Auxiliary switch (AX) d (1c) d (1c) Shunt trip (SHT) d (for relay type) (*3) d (for parallel relay type: AC only) Large terminal cover (TC-L) d (*6) Flushpanel mounting brackets (FP) d Back facing wiring termnal (BT) d (*4), (*6) Lock cover (LC) d Accessory terminal cover (TC) d (*6) 20A or less : Screw terminal M4 30A : Screw termnal M5 Male tub terminal 6.3mm (#250) [Screw terminal M4 (series type only)] Main body Alarm switch / Auxiliary switch Screw terminal M3.5 Male tub terminal 2.mm (#110) Main body mounting method Srface, IEC rail mounting Flush panel mounting (option) Panel mounting International stard UL(cURus), CCC (*5) UL(UR) (*9), (*10) CE Marking EN : TUV approval EN : Self-declaration (*5) EN : TUV approval (*10) Operating characteris is Medium type (M) only. The rated current, 0.3A, 2A, 3A 7A are not applied. Notes: *1 The products are for AC use only. *2 Contact us for operating characteristics other than those mentioned above. *3 In poles equipped with a shunt tripping mechanism, the overcurrent tripping element is not operative (switched shunt tripping). *4 For back-face wiring terminals, specify if it will be used with 30A, or 20A or less. *5 UL(cURus), CCC, CE Marking are displayed on stard products. *6 It is recognition of UL(cURus), CCC, TUV. *7 In case of DC use, only DC65V is available. * Specify if for DC use when ordering. *9 Specify when ordering. (In case of CP-S UL, type name is CP-SU.) *10 is male tub terminal only. *11 CP30-BA only. Remarks: 1. Products for non-stard conditions are special order. (Low temperature, 1st 2nd-degree moisture fungal treatment, corrosion-resistant) 2. Although a buzzing sound may occur when an instantaneous type becomes 0% or more of the rated current for AC use, performance is not effected. Please take this point into consideration when selecting units for use in quiet environments. 3. Please use in environments free of high temperatures, humidity, dust, corrosive gas, vibration, impact. Also, do not use it in a circuit with inrush current or harmonics. Problems may result. Other

48 Low-Voltage Circuit Protectors Other Internal circuits examples of application Internal circuit Serial type Available model Internal accessories Auxiliary switch (AX) Operates in conjunction with the main circuit operating mechanism to electrically retrieve the ON/OFF status of protector. Alarm switch (AL) Operating characteristics Instantaneous type High speed type Medium speed type Low speed type shunt trip I F FD M MD S SD CP30-BA d d d d d d CP-S d d d d d d d Serial type with auxiliary switch CP30-BA d d d d d d CP-S d d d d d d d Serial type with alarm switch CP30-BA d d d d d d Relay type shunt trip (with SHT) SHT CP-S d d d d d d d CP30-BA d CP-S d Parallel type shunt trip (with SHT) SHT CP-S d Relay type current trip Parallel type current trip Switch type CP-S d d d d d d d CP-S d d d d d d d CP-S Operates in conjunction with the main circuit operating mechanism to electrically retrieve the tripping status of protector. Remarks (1) When the hle of CP30-BA is constrained in the ON status, it Remarks (1) does not issue the alarm signal even if it is tripped. Remarks (2) The alarm switch will be reset when the body is reset or turned on. Shunt trip (SHT) A parallel relay type protector, which can break the circuit instantaneously when receiving an external signal Inertial delay device The inertial delay device is designed to avoid unnecessary operation caused by inrush current of transformer or lamp load. The device can withst unrepeated one pulse of crest value 20 times higher than the rated current (pulse time = ms). It can be added to circuits having high, medium low speed operating characteristics. (It cannot be added to instantaneous or DC types.) dratings of alarm switches (AL) auxiliary switches (AX) (1) For CP30-BA AC DC Classification Voltage Current (A) Voltage Current (A) (V) Resistive load Inductive load (V) Resistive load Inductive load Ratings of For (250) (1) (0.5) Max. items other general than those load Min. 0.1A/15VAC 0.1A/15VDC shaded in For minute Max Table 1 load Min. 1mA/24VDC, 2mA/12VDC, 5mA/6VDC For (250) (1) (0.5) (50) (1) (0.5) Ratings Max. general (1) 30 (2), 0.5 (1) of items load Min. 0.1A/15VAC 0.1A/15VDC shaded in Table 1 For minute Max. 125 (0.5), (0.5), 0.1 load Min. 1mA/24VDC, 2mA/12VDC, 5mA/6VDC Remark: 1. The switches having the ratings in parentheses are manufactured at the Remarks: 1. customer s request. (Specify the voltage). Such switches do not conform to UL Remarks: 1. (curus), CCC or CE Marking requirements. (2) For CP-S AC DC Voltage (V) Current (A) Current (A) Voltage (V) Resistive load Inductive load Resistive load Inductive load Remark: 1. When using these switches to a circuit with a minute load (125 V AC, 0.1 A or Remarks: V DC, 0.1 A or less), designate the application as minute load. dratings of shunt trip (SHT) coils (1) For CP30-BA Ratings Rated operating voltage (V) -200 Compatible with to 200 V AC V DC 24-4 Compatible with 24 to 4 V DC (2) For CP-S Ratings Rated operating voltage (V) Compatible with to 120 V AC (50/60Hz) 200 Compatible with 200 to 240 V AC (50/60Hz) 24, 4, DC24, DC4, DC doperation of auxiliary switch alarm switch Time rating 10 sec or less Coil resistance, resistance impedance (at25 C) Voltage (V) Impedance for AC (W) DC resistance for DC (W) Remarks: 1. The allowable range is to 110% of the rated voltage for AC 75 to 120% Remarks: 1. of the rated voltage for DC. Remarks: 2. The time rating is 10 seconds or less. Configure the circuit on which voltage Remarks: 1. will not be applied for more than 10 seconds. Time rating 10 sec or less Coil resistance, resistance impedance (at25 C) Voltage (V) Impedance for AC (W) DC resistance for DC (W) Remarks: 1. The allowable range is to 110% of the rated voltage for AC 75 to 120% Remarks: 1. of the rated voltage for DC. Remarks: 2. The time rating is 10 seconds or less. Configure the circuit on which voltage Remarks: 1. will not be applied for more than 10 seconds. AX AL AX AL Protector status Off or trip Off or ON ON Trip Switch status CP30-BA, CP-S AXa (open) / ALa (closed) AXb (open) / ALb (closed) AXc / ALc AXa (closed) / ALa (open) AXb (closed) / ALb (open) AXc / ALc Table 1 List of numbers of internal accessories which can be fitted AL AX AL or AX SHT AX AX More than one AL AL+AX SHT AL+SHT or AX+SHT AL+AX+SHT Type name 1P 2P 3P 1P 2P 3P 3P 1P 2P 3P 1P 2P 3P 1P 2P 3P 1P 2P 3P 3P CP30-BA CP-S Remark: 1. All accessories should be fitted on the internal accessory terminal block.

49 Low-Voltage Circuit P.664 Magnetic Contactor Starters P.50 9 connection method With screws On IEC rails With embedded fittings On panel Appearance posture The operating characteristics of electromagnetic (instantaneous) type circuit protectors are not affected by the installation posture. However, when installing a fluid electromagnetic (high, medium or low speed) type circuit protector, pay attention to the installation angle because the operating current value is changed under the influence of the gravity applied to the iron core in the oil dash pot. Generally, it is recommended to use the circuit protectors in the vertical direction. Circuit protectors with AL, AX /or SHT cannot be installed by this method. CP30-BA d d d CP-S d Electric wires which can be connected applicable screw terminals CP30-BA Classification Shape of terminal Electric wire size used (mm 2 ) Applicable screw terminals Tightening torque (N m) Body Alarm auxiliary switch terminals Threaded terminal (stard specification) Wire retaining screw (square washer) Cross recessed or slotted *Use the screw terminal -5NS made by JST. Cross recessed or slotted 20 A or less M4 30A M3.5 M5 ON 115% Reference for change 120% ON 115% No change in this direction ON ON ON % % ON ON R R R2-4 R R5.5-4 R *-5NS (made by JST) R R % ON ON 95% 90% M M Other

50 710 Low-Voltage Low Voltage Air Other dlow Voltage Air (AE-SW Series) Frame (A) Model AE630-SW AE0-SW AE1250-SW AE1600-SW AE2000-SWA AE2000-SW AE2500-SW AE3200-SW AE4000-SWA Image Rated current (CT rating) In (A) 630 (*1) (*1) Rated current setting Ir (A) (adjustable) (Rated ambient temperature 40 C) (For marine use 45 C) (*1) (*1) Number of poles 3, 4 (*2) Rated insulation voltage V 0 Current carrying capacity of neutral pole A Rated breaking capacity (ka symmetrical RMS) AE1600-SW (Drawout type) IEC , EN AC690V BS JIS C Ann.1 Ann.2 AC600V NK, LR, GL, BV, ABS, DNV, CCS AC V 65 5 Ics = % Icu % Rated short-time withst current (ka symmetrical RMS) 1 second Suitability for isolation Compatible Reverse connection Possible Number of operating cycles Without current With current (690 V AC) Utilization category B Pollution degree 3 EMC environment condition (environment A or B) A Fixed product Outline dimension (mm) type product Height (H) x width (W) x depth (D) Drawout product type product Fixed product type product Weight (kg) Drawout product (Without Accessory) type product Cradle product only product CE Marking Self-declaration CCC recognition ( Certified) Marine approval Certified (NK, LR, GL, BV, ABS, DNV, CCS) Automatic tripping device Electronic (effective value detection) dwhen the MCR is provided, the breaking capacity may be changed. See the catalog of Low Voltage Air, Y dsee the catalog of Low-voltage Air, Y-0622, for the details of the accessories. Notes: *1 AE630-SW AE2000-SW having low rating types are available. See the catalog of Low Voltage Air, Y-0622, for the details. *2 The products do not have obtained the marine approval. *3 4 (HN) means the neutral poles current capacity is 50% of the rated current, for 4poles. 4 (FN) means the neutral poles current capacity is % of the rated current, for 4poles. *4 ( ) shows the value for 4P FN type. *5 Marine approval value is 13kA. Features d Higher reliability by High operating durability (Mechanical) d Increase of rated short-time withst current Combination of the Electronic trip relay (ETR) with MCR (*1) enables increase of the choice coordination range. d Applicability to increase decrease of load improvement of protection coordination The electronic tripping system enables detailed setting of tripping characteristics. The system uses RMS detection resistant to distorted waves. d More improved Electronic trip relay (ETR) transmission functions To flexibly meet various requirements, functions suitable for purposes can be selected effectively. In addition, improved measuring functions are provided, so that the circuit breakers are applicable to CC-Link, PROFIBUS-DP MODBUS transmission helpful in establishing various electrical circuit measurement monitoring systems energysaving systems in combination with measuring display unit breakers. s s Model Fixed type (FIX) Drawout type (DR) Note: Horizontal (stard) (Stard) (Stard) dsee the catalog of Low Voltage Air Circuit, Y-0622, for the details. d Various connections Various connections for panel structures are available. (See the following figure.) Vertical (*1) (VT) FIX-VT Front (FT) Vertical terminal adapter (VTA) (FIX-VTA) Front terminal adapter (FTA) (FIX-FTA) (DR-VT) (DR-FT) (DR-VTA) (DR-FTA) *1 For AE2000-SWA, AE4000-SWA, AE4000-SW, AE5000-SW AE6300-SW models, vertical terminal only is available. Note: *1 MCR is an abbreviation for marking current release. It has INST characteristic only when the circuit breaker in the OFF state turns ON (closes). The circuit breaker will lose the INST characteristic after closing, it will have LTD STD characteristics.

51 Low-Voltage Circuit P.664 Magnetic Contactor Starters P dlow Voltage Air (AE-SW Series) Frame (A) Model AE4000-SW AE5000-SW AE6300-SW Image (Reference) Rated current (CT rating) In (A) Rated current setting Ir (A) (adjustable) (Rated ambient temperature 40 C) (For marine use 45 C) Number of poles 3, 4 (HN, FN) (*3) Rated insulation voltage V 0 Current carrying capacity of neutral pole A 2000 (4000) (*4) 2500 (5000) (*4) 3150 (6300) (*4) Rated breaking capacity (ka symmetrical RMS) AE6300-SW (Drawout type) IEC , EN AC690V 5 BS JIS C Ann.1 Ann.2 AC600V 5 NK, LR, GL, BV, ABS AC V 130 (*5) Ics = % Icu % dsee the catalog of Low Voltage Air Circuit, Y-0622, for the details. Rated short-time withst current (ka symmetrical RMS) 1 second Suitability for isolation Compatible Reverse connection Possible Number of operating cycles Without current 00 (3P) /5000 (4P) With current (690 V AC) 0 Utilization category B Pollution degree 3 EMC environment condition (environment A or B) A Fixed product Outline dimension (mm) type product Height (H) x width (W) x depth (D) Drawout product type product Fixed product type product Weight (kg) Drawout product (without Accessory) type product Cradle product only product CE Marking Self-declaration CCC recognition ( Certified) Marine approval Certified (NK, LR, GL, BV, ABS) Automatic tripping device Electronic (effective value detection) Electronic trip relay (ETR) Type code Main setting module WS1, WB1, WM1, AE SW, WF1 AE SW, AE4000-SW WS2, WB2, WM2, AE2000-SWA, WF2 AE4000-SWA, AE5000-SW WS3,WB3,WM3, AE6300-SW WF3 WS : General use WM : Generator protection use WB : INST/MCR only WF : Protective coordination use Optional setting module Power supply G1: Ground fault protection P1: AC DC-240V N5: Neutral pole 50% protection E1: Earth leakage protection AP: 2nd Additional Pre-alarm NA: Without optional setting ETR Auxiliary Equipment Temperature alarm(tal) MCR switch(mcr-sw) P2: DC24-60V P3: AC-240V / DC-125V with output contact P4: DC24-60V with output contact P5: DC-240V with output contact (SSR) Additional function For the details of the characteristics, alarm contact output exped functions of the ETR, see the catalog of Low Voltage Air, Y Extension module(ex1) Display(DP1) Display onto panel board(dp2) VT unit(vt) Network BIF-CC BIF-PR BIF-MD Wire system (when EX1 is specified) 3φ3W 3φ4W EX1 Normal connection Reverse connection Normal connection: Upper terminal is connected to power supply. Reverse connection: Lower terminal is connected to power supply. *The display is optional. Other

52 712 Low-Voltage Relays Other Relays Model Model name of ZCT combined (*5) Control voltage AC V JIS UL/JIS UL/CE Built-in contact High speed type Delay type High speed type High speed Delay type High speed type Delay type Image Phase line type Interchangeable leakage relays (*1) Electrical self-hold type Mechanical self-hold type Harmonic surge ready Harmonic surge ready Electrical self-hold type Mechanical self-hold type Hole diameter mm NV-ZBA NV-ZSA NV-ZHA NV-ZLA 15 ZT15B ZT15B ZT15B ZT15B 30 ZT30B ZT30B ZT30B ZT30B 40 ZT40B ZT40B ZT40B ZT40B 60 ZT60B ZT60B ZT60B ZT60B 0 ZT0B ZT0B ZT0B ZT0B ZTB ZTB ZTB ZTB JIS UL/JIS (*2) UL/CE (*3) Rated sensitivity current ma selectable selectable selectable selectable selectable selectable Max. operating time (s) Rated sensitivity current ma selectable 3f4W, 3f3W, 1f3W, 1f2W selectable selectable ( selectable) selectable selectable selectable selectable 40 Operating time (s) (*4) selectable selectable Inertial non-operating time (s) or longer than (s) Rated sensitivity current ma Max. operating time (s) Rated sensitivity current ma selectable selectable Max. operating time (s) (*4) selectable selectable Inertial non-operating time (s) or longer than (s) Rated sensitivity current ma selectable selectable Max. operating time (s) at 5I n Rated sensitivity current ma selectable selectable selectable selectable Max. operating time (s) at 2I n (*4) selectable selectable Inertial non-operating time (s) at 2I n Earth leakage indication Electric type (LED) Mechanical type (button) Electric type (LED) Mechanical type (button) Resetting method Push button or control power switch off Push button (conbined with earth leakage indicator) Push button or control power switch off Push button (conbined with earth leakage indicator) Configuration 1c 1a1c 1a1c 1a1c Continuous current capacity A Contact capacity A cosf=1 cosf=0.4 L/R= VAC VAC VDC 5 2 cosf=1 cosf=0.4 L/R= VAC VAC VAC VDC 4 3 VDC VDC cosf=1 cosf=0.4 L/R= VAC VAC VDC 5 2 Use auxiliary relay for AC415V contact. cosf=1 cosf=0.4 L/R= VAC VAC VAC VDC 3 3 Front dclamp terminal dclamp terminal dclamp terminal dclamp terminal Rear dclamp terminal dclamp terminal dclamp terminal Stard attachment (Front connection) Mounting screw Mass kg Relay External Terminal cover d (TC-ZBA) d (TC-ZSA) d (TC-ZSA) (*6) d (TC-ZSA) (*6) accessories Mounting hook for IEC 35mm rail (DIN rail) Fixture d (DIN-ZBA) Max. consumption VA 3 Conforming stard US UL stard (UR certified) UL1053 Recognized component (File No.E196562) UL1053 Recognized component (File No.E196562) Canada CSA stard LR10303(Certified No.) LR10303(Certified No.) European CE marking Notes: *1 Interchangeable leakage relays can be easily combined with other relays our ZCT. However, products with 30mA sensitivity (excluding NV-ZHA/ZLA) can only be used in combination with ZT15B, ZT30B ZT40B. *2 Indicates the UL-stard control voltage. UL, CSA JIS stards are indicated together. For JIS voltage indications, -200V changeover is V changeover, V changeover is V changeover, 460V 40V are described together. When ordering, specify UL/ JIS. *3 Indicates the UL-stard control voltage. UL, CSA CE stards are indicated together. For CE voltage indications, V changeover is V changeover, V changeoever is V selectable, which are described together. When ordering, specify UL/CE. *4 When operating times are sec, sec 1.6sec, the relay operates between sec, sec sec, respectively. *5 Can be combined with an interchangeable ZCT equipped with a primary conductor. Refer to the next page for details. *6 Not UL-certified. Declaration for conformity IEC AnnexB EN AnnexB Declaration for conformity IEC AnnexB EN AnnexB Remarks: 1. Relays with rates shown in parentheses are specialorder. 2. The relay complies with CE marking conformity declaration only when used with CE marking type MCCB with a voltage tripping device to interrupt current during ground fault. 3. NV-ZBA/ZSA Control voltage Available voltage range Example of applicable circuit voltage 120V 0-126V 110V 120V 240V V V 415V V V 4.NV-ZHA/ZLA Control voltage Available voltage range Example of applicable circuit voltage 120V 0-132V V 240V V V 440V V V 40V 36-52V V

53 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Interchangeable ZCT Type ZT15B ZT30B ZT40B ZT60B ZT0B ZTB Aperture diameter (mm) Mass (kg) Rated short time current ZCT aperture diameter wire size ELRs with a ZCT with primary conductors 50 (peak value) (mm) a d a e 1f2w 1f3w 3f3w 3f4w b c b c d e ZCT aperture diameter (mm) Interchangeable ZCTs with primary conductors Max. 600V rated wire size in mm 2 (current in amperes) Polyvinyl-chloride insulated wire 14 () 60 (217) 150 (395) 325 (650) 600 (992) 00 (115) Cross-linked polyethylene insulated cable 2 (33) 3 (190) 60 (260) 250 (655) 400 () 600 (1140) Polyvinyl-chloride insulated wire (61) 3 (162) (29) 250 (556) 500 (42) 725 (1095) Cross-linked polyethylene insulated cable 2 (33) 22 (135) 60 (260) 200 (560) 325 (760) 600 (1140) Polyvinyl-chloride insulated wire (61) 3 (162) (29) 150 (395) 325 (650) 600 (992) Cross-linked polyethylene insulated cable 14 (105) 3 (190) (365) 250 (655) 400 () Type ZTA600A ZTA1200A ZTA2000A Number of poles 3 Rated voltage (VAC) 600 Rated short time current (ka) a b ba ca c (peak value) a b ba c ca Frame (A) Type ZBA ZSA ZHA ZLA Interchangeable ELR interchangeable ZCTs with primary conductors Number of poles 3 Rated voltage (VAC) 600 Rated short time current (ka) a b ba ca c (peak value) NV-ZBA3200 NV-ZSA3200 NV-ZHA3200 NV-ZLA3200 a b ba c ca Mass (kg) Specification of ELRs High-speed type Time-delay type High-speed ( Time-delay type) Control voltage (VAC) Rated current sensitivity (ma) Max. operating time (s) Inertial non-operating time (s) ZBA (*1) (*1) ZSA (*1) (*1) (*1) 0.1 ZBA (*1) (*1) (*1) ZSA ZHA (*1) (*1) (*1) (*1) (*1) ( (*1)) (*1) (*1) (*1) (*1) (*1) (*1) (at 2l n) (at 2l n) Other ZLA (*1) (*1) (*1) (*1) (*1) (*1) (*1) (at 2l n) (at 2l n) Note: *1 Selectable.

54 714 Low-Voltage Mag only, DC, DSN 400Hz Other Special-purpose Mag Only (Instantaneous Tripping ) Fixed Adjustable NF63-CV/SV/HV NF125-CV/SV/HV NF250-CV/SV/HV NF400-CW/SW NF630-CW/SW NF00-SEW AC, DC AC, DC AC, DC AC, DC Remarks: 1. The size, weight, accessories, etc., are all identical to the same-designation C, S H series breakers. 2. For more details, contact your dealer. DC MCCBs DSN Switches AC Rated current x 10 (AC) (DC) High: Rated current x 10 Low: Rated current x 2 NF00-SDW DC High: 000A Low: 3200A NF0-SEW NF1250-SEW NF1600-SEW NF1250-SDW NF1600-SDW AC AC DC High: Rated current x 10 Low: Rated current x 2 High: Rated current x 10 Low: Rated current x 2 High: 000A Low: 3200A Breaking is more difficult with direct currents because the current value never reaches zero. While ordinary DC breakers are suitable for low voltages, special-voltage DC breakers are recommended for voltages in excess of 250VDC. for 550V are all models. The size, shape, drilling plan, accessories, etc., are all identical to the S Series breakers with the same designations. Wiring diagram for DC usage. Wiring diagram for DC use. Remark: 1. The tripping characteristics will change if the wiring differs from the one shown here. Model NF63-SV NF125-SV NF250-SV NF400-SW NF630-SW NF00-SDW NF1250-SDW NF1600-SDW Number of poles Rated voltage (VDC) Rated breaking capacity (ka) IEC (Icu/Ics) Remark: 1. Time constant: 10ms or below. 2/2 10/10 20/20 40/40 40/40 40/40 40/20 40/20 DC side These breakers are designed as thyristor-leonard system DC side breakers. They protect the thyristor from short circuiting when there is a power or communication failure (Mag Only breakers can also be used for this purpose). Use these breakers in combination with fast fuses for even greater protection. Model NF125-SV NF250-SV NF400-SW NF630-SW NF00-SDW NF1250-SDW NF1600-SDW Number of poles Rated voltage (VDC) Rated breaking capacity (ka) IEC (Icu/Ics) 40/40 10/10 20/20 20/20 20/20 20/20 20/20 20/20 Instantaneous trip current (min.) 3 times rated current 3 times rated current 900A 0A 1400A 2500A 3200A

55 Low-Voltage Circuit P.664 Magnetic Contactor Starters P DSN switches These are stard MCCBs without the automatic tripping element. The tripping capacity is about six times the rated current. The appearance, size, drilling plan available accessories are all identical to similar stard S C Series MCCBs. Model DSN63-CV DSN125-CV DSN250-CV DSN400-CW DSN630-CW DSN00-CW Rated current (A) Number of poles Rated voltage (AC/DC) 500/ / / / / /250 Max. switching current (AC/DC) 37/ / / /0 370/ /2000 Model DSN32-SV DSN63-SV DSN125-SV DSN125-SGV DSN160-SGV DSN250-SV DSN250-SGV DSN400-SW DSN630-SW DSN00-SW DSN0-SW DSN1250-SW DSN1600-SW Rated current (A) Number of poles Rated voltage (AC/DC) 500/ / / / / / / / / / / / /250 Max. switching current (AC/DC) 192/0 37/ / / / / / /0 370/ / / / / Hz MCCBs Stard MCCBs cannot be used in 400Hz circuits. When stard MCCBs are used in high-frequency circuits (eq. 400Hz), the instantaneous characteristics are shifted higher. The 400Hz MCCB is recommended for use in 400Hz circuits. The appearance, size, rated interrupting capacity, drilling plan, accessories, etc., are all identical to the stard S H Series breakers of the same designation. Rated current (A) Model NF125-SV NF125-HV NF250-SV NF250-HV NF400-SW NF400-SEW NF630-SW (*1) NF630-SEW NF00-SEW NF1250-SEW NF1600-SEW 16, 20, 32, 40, 16, 20, 32, 40, 50, 63, 0, 50, 63, 0, 125, , , , , , adjustable 400, adjustable adjustable adjustable adjustable Number of poles Rated insulation voltage (V) V / 10/ / 10/ 10/10 10/10 10/10 10/10 10/10 25/13 25/13 500V 1/1 30/23 30/30 50/3 30/30 30/30 30/30 30/30 30/30 65/33 65/33 Special-purpose Rated breaking capacity (ka) IEC (Icu/Ics) 440V 25/25 50/3 36/36 65/65 42/42 42/42 42/42 42/42 42/42 5/43 5/43 400V 30/30 50/3 36/36 75/75 45/45 50/50 50/50 50/50 50/50 5/43 5/43 230V 50/50 /75 5/5 / 5/5 5/5 5/5 5/5 5/5 125/63 125/63 Note: *1 Instantaneous trip current : Rated current x 14 (Fix) Other

56 716 Low-Voltage Other Types Table 1 S H MBR UUL BH C S HIn case of clamp connection (*3)CRemarks ELCB MCCB Note NF30-CS NF32-SV NF63-CV NF63-SV NF63-HV NF125-CV NF125-SV NF125-HV NF125-SEV NF125-SGV NF125-LGV NF125-HEV NF125-HGV NF160-SGV NF160-LGV NF160-HGV NF250-CV NF250-SV NF250-HV NF250-SEV NF250-HEV NF250-SGV NF250-LGV NF250-HGV NF400-SW NF400-SEW NF400-HEW NF400-REW NF400-CW NF630-SW NF630-SEW NF630-HEW NF630-REW NF630-CW NF00-SEW NF00-HEW NF00-REW NF00-SDW NF00-CEW NF0-SEW NF1250-SEW NF1600-SEW NF125-UV NF125-RGV NF250-RGV NF250-UV NF400-UEW NF00-UEW NF50-SVFU NF-CVFU NF125-SVU NF125-HVU NF250-SVU NF250-HVU NF225-CWU NF-SKW NF-SLW BH-K BH-C1 BH-C2 BV-C1 BV-C2 BH-P NV32-SV NV63-CV NV63-SV NV63-HV NV125-CV NV125-SV NV125-HV NV125-SEV NV125-HEV NV250-CV/SV/HV NV250-SEV/HEV NV400-SW NV400-SEW NV400-HEW NV400-REW NV400-CW NV630-SW NV630-SEW NV630-HEW NV630-CW NV00-SEW NV00-HEW Shape Screw size Type type (Code address) NF32-SV 63-CV 63-SV 63-HV 50-SVFU(*1) Image Screw terminal (AMP-N) Please refer to page 720. A (Only load side) Front connection (F) Busbar terminal (BAR) A B Solderless (BOX) terminal (SL) Kind of terminal screw (A) (Circuit breakers having frame size of 0A more are not provided with terminal screws (A).) Pan-head screw with clamp M5 BH-P NV32-SV 63-CV 63-SV 63-HV qwhen the wire size is 5.5 mm 2 or more, divide the wires, connect them. wwhen connecting wires differing in size, for example, f1.6 wires 5.5-mm 2 wires, connect the two kinds of wires together to a crimp terminal because the thinner wires easily come off. edo not tighten directly solid wires cords consisting of thin copper wires used as strs, for example f mm 2 wires, together. NF NV 63-CV(60, 63A) 63-SV(60, 63A) 63-HV(60, 63A) 125-CV 125-SV 125-HV 125-SEV 125-HEV -CVFU 125-SVU 125-HVU 125-UV 63-CV(60, 63A) 63-SV(60, 63A) 63-HV(60, 63A) 125-CV 125-SV 125-HV 125-SEV 125-HEV *1 It is impossible to directly connect the wires of A, NF/NV 50-SVFU. Pan-head screw Bolt (Hex-socket) M M 2 M NF 125-SEV 125-HEV 125-RGV 125-SGV 125-LGV 125-HGV 160-SGV 160-LGV 160-HGV 250-CV 250-SV 250-HV 250-SEV 250-HEV 250-SGV 250-LGV 250-HGV 250-RGV 250-UV 225-CWU 250-SVU 250-HVU NV 125-SEV 125-HEV 250-CV 250-SV 250-HV 250-SEV 250-HEV NF NV 400-UEW 00-SEW (4P) 00-HEW 00-CEW 00-SEW 00-HEW 00-REW 00-UEW 00-SDW Bolt M10 NF 400-CW 400-SW 400-SEW 400-HEW 400-REW 400-UEW(3P) 630-CW 630-SW 630-SEW 630-HEW 630-REW NV 400-CW 400-SW 400-SEW 400-HEW 400-REW 630-CW 630-SW 630-SEW 630-HEW Bar stud (B-ST) Rear (B) Round stud (B-ST) B With insulating base (tube) for installation of metallic board The bar stud installation position can be turned 90 on all models (except NF00-UEW). The current-carrying capacity of a vertically installed bus bar is larger than that of a horizontally installed bus bar even if the bus bars have the same dimensions.

57 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Bar stud (PM) Plug-in (PM) Screw terminal (PM) Plug-in type for distribution board For distribution board for electric lamps (BPA) (Except for NF1600-SEW) (Except for 4P) (Except for NF00-UEW) (Except for 4P) Table 2 List of terminal screws (B) ModelCMCCB ELCB S HUC S H The circuit breaker can be connected only by pushing it onto the preliminarily wired terminal block. Install it tightening the supplied screws through the mounting holes. type NF400-CW NF400-SW NF400-SEW NF400-HEW NF400-REW NF630-CW NF630-SW NF630-SEW NF630-HEW NF630-REW NF00-CEW NF00-SEW NF00-HEW NF00-REW NF00-SDW NF-SKW NF-SLW NF0-SEW NF1250-SEW NF1600-SEW NF400-UEW NF00-UEW NV400-SW NV400-SEW NV400-HEW NV400-REW NV400-CW NV630-SW NV630-SEW NV630-HEW NV630-CW NV-SKW NV00-SEW NV00-HEW Mounting base for distribution board for electric lamps. Front Rear Plug-in M12 bolt M12 bolt M10 bolt M12 bolt M12 bolt M12 bolt M12 bolt Other

58 71 Low-Voltage Other Connecting Parts For the connection shown in the table on the previous page, the following parts are available as connecting parts. Table 3 Studs on rear surface (B-ST) Type name Number Applicable models of poles MCCB ELCB ST-05SV2 2 NF32-SV, NF63-CV, NF63-SV NV32-SV, NV63-CV ST-05SV3 3 NF63-HV NV63-SV, NV63-HV ST-05SV4 4 NF63-SV, NF63-HV ST-1SV2 2 ST-1SV3 3 NF125-CV, NF125-SV NF125-HV(3, 4P) NV125-CV, NV125-SV ST-1SV4 4 NV125-HV ST-1HV2 2 NF125-HV(2P) ST-2SV2 2 NF125-SEV, NF125-HEV, NF125-RGV NF125-SGV, NF125-LGV, NF125-HGV ST-2SV3 3 NF160-SGV, NF160-LGV, NF160-HGV NF250-SGV, NF250-LGV, NF250-HGV NF250-CV, NF250-SV NV125-SEV, NV125HEV NF250-LGV/HGV, NF250-HV NV250-CV, NV250-SV ST-2SV4 4 NF250-SEV, NF250-RGV NV250-HV, NV250-SEV NF250-HEV, NF125-SGV/HGV NV250-HEV NF125-LGV, NF160-SGV NF160-LGV/HGV ST-4SW2 2 NF400-CW, NF400-SW ST-4SW3 3 NV400-CW, NV400-SW NF400-SEW, NF400-HEW NV400-SEW NF400-REW NV400-HEW ST-4SW4 4 NV400-REW ST-6SW2 2 NF630-CW, NF630-SW ST-6SW3 3 NF630-SEW, NF630-HEW NV630-CW, NV630-SW NF630-REW ST-6SW4 4 NV630-SEW, NV630-HEW ST-SW2 2 ST-SW3 3 ST-SW4 4 NF00-SDW, NF00-CEW NF00-SEW, NF00-HEW NF00-REW Table 4 Plug-in type terminal blocks (PM) NV00-SEW, NV00-HEW Type name Number of poles Applicable models Set of order Major included parts PMDN-05SV2L 2 NF32-SV NF63-CV/SV/HV (3A-50A) PMDN-05SV3L 3 NF32-SV NF63-CV/SV/HV (3A-50A) sets Plug-in type terminal block (1 pc) PMDN-05SV4L 4 NV32-SV NV63-CV/SV/HV (5A-50A) Crip terminals (2-pole: 4pcs, : 6 pcs, : pcs) PMDN-05SV2H 2 NF63-CV/SV/HV (60A, 63A) PMDN-05SV3H 3 NF63-CV/SV/HV (60A, 63A) PMDN-05SV4H 4 NV63-CV/SV/HV (60A, 63A) PMDN-1SV2 2 NF125-CV/SV PMDN-1HV2 2 NF125-HV Plug-in type terminal block (1 pc) sets Crip terminals PMDN-1SV3 3 NF125-CV/SV/HV (2-pole: 4 pcs, : 6 pcs, : pcs) PMDN-1SV4 4 NV125-CV/SV/HV PMDN-1UV2 2 PMDN-1UV3 3 Plug-in type terminal block (2 pc) NF125-UV sets Crip terminals (2-pole: 4pcs, : 6 pcs) 4 PMDN-2SV2 2 NF125-SEV/HEV/SGV/LGV/HGV PMDN-2SV3 3 NF160-SGV/LGV/HGV Plug-in type terminal block (1 pc) NF250-CV/SV/HV/SEV/HEV/SGV/LGV/HGV Plug-in type barriers PMDN-2SV4 4 NV125-SEV/HEV sets (2-pole: 2 pcs, : 4 pcs, : 6 pcs) NV250-CV/SV/HV/SEV/HEV Tulip terminals PMDN-2SV2 2 (2-pole: 4 pcs, : 6 pcs, : pcs) NF125-RGV, NF250-RGV PMDN-2SV3 3 PMDN-2UV2 2 Plug-in type terminal block (2 pc) PMDN-2UV3 3 NF250-UV sets Plug-in type barriers (2-pole: 2 pcs, : 4 pcs) 4 Tulip terminals (2-pole: 4pcs, : 6 pcs) PMDN-4SW2 2 NF400-CW/SW 3 NF400-CW/SW/SEW NV400-CW/SW/SEW PMDN-4SW3 Plug-in type terminal block (2 pcs) 3 NF400-HEW/REW sets Plug-in type barriers (4 pcs) NV400-HEW/REW Tulip terminals (: 6 pcs) 4 NF400-SW/SEW PMDN-4SW4 NV400-SEW 4 NF400-HEW PMDN-SW2 2 NF00-SDW 3 NF00-CEW/SEW NV00-SEW PMDN-SW3 sets Plug-in type terminal block (2 pcs) NF00-HEW/REW 3 Tulip terminals (: 6 pcs) NV00-HEW 4 NF00-SEW PMDN-SW4 4 NF00-HEW Note In addition to the circuit breakers shown above, 2-pole circuit breakers are available. We are ready to manufacture such circuit breakers to order. Please consult us. Set of order sets sets sets sets sets Stud shape major included parts Round studs Round studs (with insulating tube) (2-pole: 4 pcs, : 6 pcs, : pcs) Bolts nuts Bar studs Bar studs (with insulating tube) (2-pole: 4 pcs, : 6 pcs, : pcs) Bolts nuts Bar studs Bar studs (with insulating tube) (2-pole: 4 pcs, : 6 pcs, : pcs) Bolts nuts Bar studs Insulating bases (2-pole: 4 pcs, : 6 pcs, : pcs) Bar studs (2-pole: 4 pcs, : 6 pcs, : pcs) Mounting screws, bolts nuts Bar studs Insulating base (2 pcs) Bar studs (2-pole: 4 pcs, : 6 pcs, : pcs) Mounting screws, bolts nuts Remarks One set includes the parts for one unit. Please place an order for the number of circuit breakers.

59 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Stard Tightening Torque Rear <Round stud> Fig. 1 <Bar stud> Fig. 2 Model MCCB NF30-CS Screw A Screw A NF32-SV, NF63-CV NF63-SV, NF63-HV NF125-CV, NF125-SV NF125-HV, NF125-UV NF125-SEV, NF125-HEV, NF125-RGV NF250-CV, NF250-SV, NF250-HV, NF250-SEV NF250-HEV, NF250-RGV, NF250-UV NF250-LGV/HGV, NF250-RGV, NF125-SGV/HGV NF125-LGV, NF160-SGV, NF160-LGV/HGV NF125-SGV, NF125-LGV, NF125-HGV NF160-SGV, NF160-LGV, NF160-HGV NF250-SGV, NF250-LGV, NF250-HGV NF400-CW, NF400-SW, NF400-SEW NF400-HEW, NF400-REW NF400-UEW (3P) NF400-UEW (4P) NF630-CW, NF630-SW NF630-SEW NF630-HEW, NF630-REW NF00-CEW, NF00-SDW NF00-SEW, NF00-HEW, NF00-REW NF00-UEW (*2) NF0-SEW NF1250-SEW NF1600-SEW Screw E Connecting conductor Bar stud Insulating base ELCB Insulating tube type NV32-SV, NV63-CV NV63-SV, NV63-HV NV125-CV, NV125-SV NV125-HV NV125-SEV, NV125-HEV NV250-CV, NV250-SV NV250-HV, NV250-SEV NV250-HEV NV400-CW, NV400-SW NV400-SEW, NV400-HEW NV400-REW NV630-CW, NV630-SW NV630-SEW NV630-HEW NV00-SEW NV00-HEW Nut C Round stud Connecting busbar Screw A Fig. 3 Plug-in <Screw terminal> Rear Round stud Fig.1 Screw A Nut C Size Tightening torque Size Tightening torque M M6 2 M4 0.7 Screw E Table 5 Stard tightening torque (*1) 1 M6 2 Bar stud Fig. 2, Fig.3 Screw A Screw E Size Tightening torque Size Tightening torque M6 M6 M M10 M M10 4-M 4-M M M M12 M12 M12 2-M12 2-M12 4-M <Bar stud> Tightening torque N m Plug-in Screw terminal Fig.4 Screw D Size M6 M Tightening torque 3 6 Bar stud Fig.5 Screw E Size Tightening torque Notes *1 The appropriate range of tightening torque is ±20% of each value (stard tightening torque) shown in the above table. Please refer to the supplied assembly manual instruction manual for more information. *2 The plug-in type is not available. Fig. 4 Circuit breaker Connecting conductor Screw D Plug-in type terminal block Plug-in type stud Screw E Plug-in type terminal block M M12 M12 M12 2-M12 2-M12 Connecting conductor Bar stud Fig Other

60 720 Low-Voltage Crimp Terminal Type Table 6 List of applicable crimp terminals Frame (A) BH-P Nominal sectional area mm 2 Allowable current 600 V, IV wire at 30 C, not in conduit Model BH-P MCCB NF30-CS, NF32-SV, NF63-CV*, NF63-SV* NF63-HV* *50A or below NF63-CV, NF63-SV, NF63-HV 60, 63A (*4) ELCB As the terminals in, commercially available crimp terminals can be used. Please purchase the terminals at an electric material store. For others, the crimp terminals for MCCB must be used. Place an order with us. For the connection types shown in Fig. a Fig. b, only crimp terminals will be delivered A 49A 61A A 115A Size of mm 2 NV32-SV, NV63-CV*, NV63-SV* NV63-HV* *50A or below NV63-CV, NV63-SV, NV63-HV 60, 63A 1.04 to 2.63 R-2-5 R-2-5 *(R-2-6) R to 6.64 R R *(R-5.5-6) R to R--5 R-- R--5 R to 16.7 R-14-5 R-14- R-14-5 R to BH-22 (L330T459-23) R-22- JST22-S5 BH-22 (L330T459-23) R NF125-CV, NF125-SV, NF125-HV, NF125-UV 60A or more NV125-CV, NV125-SV, NV125-HV 60A or more R-2-5 (R-2-6) R-2- R (R-5.5-6) R-5.5- R--5 R-- R-14-5 R-14- JST22-S5 (L330T459-23) R-22- Other NF125-SEV, NF125-HEV, NF125-RGV NF250-CV, NF250-SV, NF250-HV, NF250-UV NF250-SEV, NF250-HEV, NF250-RGV NF125-SGV, NF160-SGV, NF250-SGV NF125-LGV, NF160-LGV, NF250-LGV NF125-HGV, NF160-HGV, NF250-HGV NF400-CW, NF400-SW, NF400-SEW NF400-HEW, NF400-REW, NF400-UEW NF630-CW, NF630-SW, NF630-SEW NF630-HEW, NF630-REW NF00-CEW, NF00-SEW, NF00-HEW NF00-REW, NF00-UEW, NF00-SDW NF0-SEW, NF1250-SEW d Reference drawings of connection types Method of connecting directly to terminal(s) of body (Fig. a) To connect one terminal To connect two terminals NV125-SEV, NV125-HEV NV250-CV, NV250-SV, NV250-HV NV250-SEV, NV250-HEV NV400-CW, NV400-SW NV400-SEW, NV400-HEW NV400-REW, NV630-CW NV630-SW, NV630-SEW NV630-HEW NV00-SEW, NV00-HEW Method of connecting to front bar terminal Connect with the bolt head downward. (Fig. b) R-14- R-22- Carefully check the insulating distance between the connecting bus bar, crimp terminal tightening bolt the ground the phase-to-phase insulating distance.

61 Low-Voltage Circuit P.664 Magnetic Contactor Starters P A to AMP #322 JST 3-S NTK R3-S AMP #322 JST 3-S NTK R3-S AMP #322 JST 3-S NTK R3-S R-3- R-3-12 R A to AF-60 (L330T459-12) CB60-S 1AF-60 (L330T459-12) CB60-S 1AF-60 (L330T459-12) CB60-S R-60- R R A 96.3 to AF (LN300T920-20) CB-S R--12 R A to CR-150(*1) (LN300T920-21) (*1)CB150-S R R RD SD A to R R RD SD A to 325 JST JST RD SD Crimp terminal tightening screw Screw size M5 M M5 M M5 M M M12 Tightening torque N m Notes *1 When using 2CR-150 or CB150-S, insulate it from TC-S with insulating tube or tape. When using CB150-SB for a 2- or circuit breaker, TCL-2SV3L is applicable. *2 On the power supply side, pan-head screws M5 are used. *3 When tightening a terminal screw without connecting a wire, crimp terminal or bar, tighten the screw to 20 to 30% of the torque shown in the above table (to prevent damage to the threads). *4 The table shows not the allowable current values of circuit breakers, but those of wires applicable to crimp terminals. Remark: 1. For the crimp terminals for UL listed circuit breakers, refer to the page of the characteristics external dimensions of. R2-5 R2-6 R2- R5.5-5 R5.5-6 R5.5- R-5-5NS R-6 R- -5SC-9 R NS R14-6 R14- L330T NS 22-S6 R22- R S R3- R3-12 L330T R60- R60-12 LN300T R-12 A A A A A B A size M5 M6 M M5 M6 M M5 M5 M6 M M5 M5 M5 M6 M M5 M5 M6 M M12 M M M12 M M M12 M M <Explanation of abbreviations> R Product specified by JIS CB Product specified by JEM 1399 AMP Product made by Nippon AMP JST Product made by J.S.T. Mfg. Co., Ltd. NTK Product made by Nippon Tanshi Co., Ltd. NTM Product made by Nichifu Co., Ltd. DST Product made by Daido Solderless Terminal Mfg. Co., Ltd to 3 5 to 7 2 to 3 5 to 7 2 to 3 5 to 7 to to 50 d of crimp terminals <extracted from catalog of JST> Part number Applicable External dimensions Applicable Shape screw wire fd2 B L F E Thickness mm 2 Part number A to A to to to to to to to to LN300T L330T402- R R CB60-S CB-S CB150-S Part number RD60-12 RD-12 RD RD RD SD SD SD Shape A B Shape φd2 F C C L Shape B A A A B Shape M5 M6 M Applicable screw size M12 M12 E Applicable screw size M M M12 M12 M12 M M5 M Remarks When connecting two crimp terminals, set the terminals as shown below if the *-marked terminals are used I R-2-5 R R-2-6 R When using 2AF, use a crimp tool having a nominal size of. Fit to a front type bar terminal. Up to two pieces can be fitted to one terminal External dimensions fd2 B L F E Thickness External dimensions fd2 B L F E N Thickness Shape B B φd2 F L E Shape C B N φd2 Reference drawing of connection type (Fig. a) (Fig. b) Applicable wire mm to to to to to to Applicable wire mm to to to to to to to to 325 F L E Other

62 722 Low-Voltage Busbar The size of the conductor can be connected is shown on the outline drawing of each model. The following special busbars are available. Use them as needed. When using any busbar, isolate it from the bare busbar on the circuit breaker power supply side with an insulating barrier. f6.5 ON OFF F 10 H H Conductor thickness t = 4 max. Nominal diameter of conductor tightening screw J C A f9 or f.5 ON OFF F G H H Conductor thickness t = 10 max. Nominal diameter of conductor tightening screw J 4 A f9 D E F 15 Fig. 1 Conductor thickness t = 6 max. C C A B D E Fig. 2 C B ON OFF H H Nominal diameter of conductor tightening screw J Other Type name FB-05SV FB-1SV FB-2SV D E NF32-SV NF63-CV (50A or below) NF63-SV (50A or below) NF63-HV (50A or below) NF125-CV, NF125-SV NF125-HV, NF125-UV Fig. 3 Table 7 Table of variable dimensions Applicable models MCCB NF125-SEV NF125-HEV, NF125-RGV NF250-CV, NF250-SV, NF250-HV NF250-UV, NF250-SEV NF250-HEV, NF250-RGV NF125-SGV/LGV/HGV NF160-SGV/LGV/HGV NF250-SGV/LGV/HGV C ELCB NV32-SV NV63-CV (50A or below) NV63-SV (50A or below) NV63-HV (50A or below) NV125-CV NV125-SV NV125-HV NV125-SEV NV125-HEV NV250-CV, NV250-SV NV250-HV, NV250-SEV NV250-HEV B Outline dimentions f6.5 f f.5 f.5 6 f9 f9 20 Fig A B C Busbar D E F G 15 H J M5 0. M M

63 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Insulation Distance on Power Source Side dbasic concept Insulation distance (distance indicated in stards) Be sure to at least secure the insulation distances (spatial distance creeping distance) specified by the codes stards of the relevant equipment facilities where the circuit breakers are installed. It is recommended that insulation barriers insulation tape be used to enhance the electrical insulation between bare-live parts between bare-live parts ground to avoid accidents otherwise caused by a loose metal piece, conductive dust, abnormal surge voltage in the circuit or a similar event so as to improve the reliability of panels. Arc Space (insulation space) At the exhaust outlet side of breaker, arc space is necessary. When the actual load circuit is opened, especially when a large current such as overload or short-circuit is interrupted, ionized gas is emitted from the exhaust outlet. This gas can cause a short circuit between bare, live parts such as busbars, also can cause grounding faults between conductive installation metal panels. Therefore, it is important to secure enough arc space at the exhaust outlet side of the breaker to strengthen insulation of parts exposed to the gas. In addition, securing enough space at the front of the exhaust outlet is necessary, because when the gas emission is blocked, failures such as deterioration of breaking performance can be caused. dinsulation required part With regard to insulation of bear, live parts of the line side of the breaker, please make sure to insulate at least C part C indicated in the diagram above with insulation tape, a tube or a terminal cover. qa : Distance from the circuit breaker to the ceiling plate wb1 : Distance from the circuit breaker to the uncovered conducting part of the upper circuit breaker terminal (front connection) eb2 : Distance from the lower circuit breaker to the end face of the upper circuit breaker (rear connection) rd1 : Distance from the side of the breaker to the side plate tc : Insulated length of the power source terminal of the circuit breaker (front connection) Please secure insulation using insulating tape, insulating tubing, insulation barrier, or a terminal cover, between bare charge parts within this size range. Please refer to a table a necessary size must. When using insulation tape insulation tubing together with insulation barriers terminal covers, make them overlap with the other by at least 10 mm. For the models with insulation barriers supplied as stard, please make sure to use the barriers. a : clearance specified in stard yd2 : Side-to-side spacing of breakers While the circuit breakers can basically be installed together without a clearance in between, be sure to observe the following instructions. It is desirable to install an insulation barrier between the adjacent circuit breakers or insulate the bare-live parts considering the effect of cutoff gas. Be sure to secure the insulation distance (dimension a) as the minimum, indispensable requirement. With a leakage circuit breaker a leakage alarm circuit breaker installed in close contact with the other, a current of 2,500A or higher flowing through one of the circuit breakers could cause the other to operate falsely. Be sure to secure a distance of at least 50 mm in between. A circuit breaker of 400-ampere frame or larger with an SHT or a UVT could operate falsely if a current of 50 ka or higher flows through the adjacent circuit breaker. Be sure to secure a distance of at least 50 mm in between. Ceiling plate A B1 B1 Table Insulation distance (mm) (440VAC or below) *Figures in parentheses are for 230VAC or below. Class Series MCCB Model ELCB B2 D1 Ceiling plate A Uncovered metal Plate Without terminal cover (30) 50(10) (40) With terminal cover Side plate Insulated plate, coated plate C Vertical spacing B1, B2 Without terminal cover With terminal cover C a D2 Horizontal spacing NF30-CS (*1) 20 NF32-SV, NF63-CV NV63-CV (*1) 20 NF63-SV, NF63-HV NV32-SV, NV63-SV, NV63-HV NF125-CV NV125-CV 40(30) (*1) 25 NF125-SV NV125-SV 30(10) NF125-HV NV125-HV C NF250-CV NV250-CV NF125-SEV, NF250-SV, NF250-SEV NV125-SEV, NV250-SV, NV250-SEV (50) 50 (50) 50 S NF125-SGV, NF160-SGV, NF250-SGV NF125-HEV, NF250-HV, NF250-HEV H NF125-LGV, NF160-LGV, NF250-LGV NV125-HEV, NV250-HV, NV250-HEV NF125-HGV, NF160-HGV, NF250-HGV R NF400-CW NV400-CW NF400-SW, NF400-SEW NV400-SW, NV400-SEW MB NF400-HEW, NF400-REW NV400-HEW, NV400-REW NF630-SW, NF630-SEW, NF630-CW NV630-CW, NV630-SW, NV630-SEW NF630-HEW, NF630-REW NV630-HEW NF00-SEW, NF00-CEW NV00-SEW NF00-HEW, NF00-REW NV00-HEW NF0-SEW, NF1250-SEW R U BH BH-K, BH-K (*1) (*1) (*1) (*1) 20 NF225-CWU (40) (40) (50) (50) (50) NF50-SVFU 10 (*6) 10 (*6) 10 (*6) 20 (*7) 20 (*7) NF-CVFU 50(25) 40(25) (15) NF125-SVU(*4) 40(10) 30(10) (20) UL NF125-HVU(*5) (20) NF250-SVU(*4) (50) 50 (50) 50(20) NF250-HVU(*5) (20) NF400-SWU, NF400-HWU(*5) NF630-SWU, NF630-HWU(*5) Remark: 1. The table shows the dimensions in the case of the use of a large terminal cover (TC-L). Notes *1 It is not necessary to provide an insulation distance (an arc space) on the power supply side. However, if a grounding metal piece or the like comes in close contact with the terminal, be sure to completely insulate the terminals or the bare-live parts of the cable conductors. *2 At more than 440 V AC, the distance shall be 10 mm. *3 For 40Y/277V AC. *4 For 40V AC. *5 For 600Y/347V AC. *6 An exhaust port is provided also on the circuit breaker load side. Secure the dimension A both on the power supply side on the load side. *7 When any of the circuit breakers NF125-RGB to NF250-RGV is used on the upstream side, an exhaust port is provided also on the circuit breaker load side. Secure the larger distance of the dimension B1 of NF125-RGV, NF250-RGV or NF50-SVFU the dimension B1 of the downstream circuit breaker. NF1600-SEW NF125-RGV, NF250-RGV 30 (*6) 30 (*6) 30 (*6) 50 (*9) 50 (*9) 50 5 NF125-UV, NF250-UV (*1) (*1) (*1) (*1) (*1) (*1) 25 NF400-UEW NF00-UEW D1 Other

64 ON ON 724 Low-Voltage / Internal Other Effect of Orientation orientation does not affect the operating characteristics of circuit breakers of electronic or thermomagnetic operation types. However, the installation orientation affects the operating current of fully magnetic type circuit breakers as the iron core in the oil dash pot is under gravitational force. It is generally suggested they be installed vertically. Hydraulic-magnetic (The same applies to other models of hydraulic-magnetic type.) Class C MCCB Model NF30-CS of Line Load The stard wiring of line load on the circuit breaker is as shown in (a) normal connection on the right. Avoid the wiring shown in (b) reverse connection. This may lead to a decrease in breaking performance. However, the reverse connection is allowed for the following models (excluding MDU breakers). NF-C, NF-S, NF-H, NF-R NF-U class BH-P, CP30-BA, NV-C, S, H R class of 400 to 00AF, NF-CVFU, NF125-SVU, NF125-HVU, NF250-SVU, NF250-HVU Reverse connection is allowed for the stard models. 107% % ON ON ON ON 110% 90% ON ON Line Load (a) Normal connection ON 107% 93% % ON Rate of change of rated current by mounting angle methods Load 93% Line (b) Reserve connection

65 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Internal The accessories to be installed in circuit breakers include the followings. For the numbers of the accessories which can be installed. The stard internal accessories have lead wires (450 mm long) drawn out. (However, some of Models UVT TBM have vertical lead wire terminal blocks as stard.) When circuit breakers are installed side by side, keep a space of mm or more for lead wires between the circuit breakers. (Models with lead wires drawn out toward load models with lead wire grooves in the side faces can be installed in close contact.) SHT (Shunt trip) Device to electrically trip a circuit breaker from a distance. The allowable operating voltage range is to 110% of the rated voltage. (JIS C Ann.1, Ann.2) Power supply Load diagram S1 S2 Pushbutton switch AL (Alarm switch) Switch to electrically display the tripping status of circuit breaker AX (Auxiliary switch) Switch to electrically display the ON-OFF status of circuit breaker Power supply ALc Load ALb Power supply AXc ALa diagram Load AXa AXb PL PL1 PL2 Control power supply Small-size MCCB or fuse Control power supply diagram UVT (Undervoltage trip) Device to automatically trip a circuit breaker when the voltage drops. The operating voltage is to 35% of the UVT rated voltage. (JIS C Ann.1) When the voltage recovers at least to 5% or more, the circuit breaker can be turned on after the device is manually reset. Power supply UC1 SLT (Lead wire terminal block) Terminals for connecting with internal accessories. The terminal block will be manufactured to order. For the detailed dimensions. (The dimensions of SLT slightly vary depending on the number of installed accessories the model.) However, circuit breakers with a frame size of 400A above having an electrical operation device are normally provided with SLT. TBM (Test button module) Unit to perform test under voltage from a distance. TBMs can be connected in parallel. (The stard TBMs are provided with SLT. In the case of the flush plate type, the external dimensions are partially different from those of the stard type.) Circuit breaker TBM TBM2 switch Control power TBM1 supply Other diagram Load UC2 TBM circuit diagram

66 726 Low-Voltage Internal Other Kinds of Internal Table 1 AL AX SHT UVT Accessory name Nameplate (sample) Accessory name Nameplate (sample) Alarm switch Auxiliary switch Shunt tripping device Undervoltage tripping device Operations Ratings of Switches Table 2 Operations of AL switch Status of circuit breaker Off or On Trip Contact status of AL switch 9/ALa (open) 96/ALb (closed) 95/ALc 9/ALa (closed) 96/ALb (open) 95/ALc * The terminal numbers 9/ALa, 96/ALb 95/ALc may vary depending on the number of installed switches the installation poles. Table 3 Operations of AX switch Status of circuit breaker Off or Trip On Contact status of AX switch 14/AXa (open) 12/AXb (closed) 11/AXc 14/AXa (closed) 12/AXb (open) 11/AXc * The terminal numbers 14/AXa, 12/AXb 11/AXc may vary depending on the number of installed switches the installation poles. EAL TBM Earth leakage trip alarm switch Test button module Table 4 Ratings of AL AX switches Applied switch A S V Remark: Voltage V (250) AC Current A Resistive Inductive load load (1) (0.5) 3 (1) Voltage V (50) The ratings in parentheses do not conform to UL. DC Current A Resistive Inductive load load (1) (2) (0.5) (1)

67 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Maximum Number of Internal MCCB Motor Protection Table 5 Table of maximum number of internal accessories Model AL C S L H R Number of poles U AL AX (stard) switches Accessory NF30-CS (*3) Left pole NF63-CV NF125-CV NF32-SV NF63-SV NF125-SV NF63-HV Hle of circuit breaker 1 Right pole NF63-CV NF125-CV NF250-CV NF32-SV NF63-SV NF125-SV NF125-SGV NF160-SGV NF250-SV NF250-SGV NF63-HV NF125-HV NF125-LGV NF125-HGV NF125-RGV NF160-LGV NF160-HGV NF250-HV NF250-LGV NF250-HGV NF250-RGV NF125-UV NF250-UV 2 S NF125-SEV NF250-SEV NF125-HEV NF250-HEV 1 AL AX SHT or UVT PAL Outgoing direction of lead wires are cassette type accessories. (Some of UVT are not provided with cassettes.) 2 NF400-CW NF630-CW NF400-SW NF400-SEW NF630-SW NF630-SEW NF400-HEW NF400-REW NF630-HEW NF630-REW NF400-UEW(3P) NF00-CEW NF00-SEW NF00-SDW NF00-HEW NF00-REW NF400-UEW(4P) NF00-UEW (*7) NF0-SEW NF1250-SEW NF1600-SEW 2 or 3 poles 2 poles 2, 3 or 4 poles 3, 4 poles 2, 3 or 4 poles 2, 3 or 4 poles 2, 3 or 4 poles V AX (*3) (*7) SHT or UVT AL + AX AL + SHT or UVT SHT AX + or UVT SHT AL + AX + or UVT (*3) product only (*1) (*1)(*5) (*1)(*5) (*2) (*2) (*1) (*1) (*1) (*1) (*1) (*1) (*1) (*6) (*7) (*1) (*6) (*7) (*) (*1) (*6) (*7) (*) (*1) (*6) (*7) (*) (*1) (*6) (*7) (*1) (*6) (*7) (*) (*1) (*6) (*7) (*) (*1) (*6) (*7) (*) (*1) (*1) (*1) (*1) PAL (contact output) Notes *1 When UVT is provided, the UVT voltage module will come in the vertical lead wire terminal block type. (SHT does not have a voltage module.) *2 The second AX can be installed in place of the AL on the left pole side. When placing an order, specify the incorporation of the switches in the body. *3 Although the lead wires are normally drawn out laterally, those with lead wires drawn out toward load are available. (Only for front connection type) *4 PAL (contact output) can be installed together with AL AX on the left pole side. (It cannot be installed together with SHT or UVT.) The stard type is provided with SLT. PAL control voltage (compatible with to 200 V AC) is necessary. *5 SHT UVT can be installed on the left side. *6 SHT UVT are normally installed on the right pole side. If you intend to install them on the left pole side, specify so. (The reset preventing UVT must be installed on the left pole side.) *7 In the case where three or more accessories are installed on the left pole side AL, AX or AL AX are installed on the pole on which SLT, SHT or UVT is installed, the SLT will be manufactured to order. * When AL, AX or AL AX are installed on the pole on which UVT is installed, the UVT voltage module must be installed separately. *9 SLT is provided as stard. A control power supply ( to 200 V AC) is required. (In this case, other internal accessories cannot be installed on the right pole side.) Remarks: 1. For electrically operated automatic reset type circuit breakers having a frame size of 400A or above, the numbers of AL switches which can be installed are smaller by 1 than the values shown above. 2. The encircled numbers indicate the order of installation. (*4) (*9) Option for NF400-SEW, HEW, REW UEW NF630-SEW, HEW REW (*9) Option for NF00-CEW, SEW, HEW REW NF00-UEW (*9) Option for NF0-SEW NF1250-SEW NF1600-SEW Other

68 72 Low-Voltage Internal ELCB Table 6 Table of maximum number of internal accessories Model C S H R U Number of poles Accessory Switch NV63-CV NV125-CV NV250-CV NV32-SV NV63-SV NV125-SV NV125-SEV NV250-SV NV250-SEV NV63-HV NV125-HV NV125-HEV NV250-HV NV250-HEV 2, 3, or 4 poles Left pole Hle of circuit breaker Right pole NV400-CW NV630-CW NV400-SW NV400-SEW NV630-SW NV630-SEW NV400-HEW NV400-REW NV630-HEW S 3 poles AL AX are cassette type accessories. NV00-SEW NV00-HEW SHT or UVT TBM Outgoing direction of lead wires (*6) AL AX 1 2 (*6) Other AL + AX SHT or UVT SHT AL + or UVT SHT AX + or UVT SHT AL + AX + or UVT TBM (*2) (*3) (*6) (*5) (*4) (*5) (*6) (*4) (*5) (*6) (*4) (*5) (*6) (*1) (*1) Notes *1 The stard type is provided with SLT. Only in the case of 24 V DC, specify the control voltage. *2 The second AX can be installed in place of the AL on the left pole side. When placing an order, specify the incorporation of the switches in the body. *3 When UVT is provided, the UVT voltage module will come in the vertical lead wire terminal block type. (SHT does not have a voltage module.) *4 When AL, AX or AL AX are installed on the pole on which UVT is installed, the UVF voltage module must be separately installed. *5 When the accessory is provided with UVT, the UVT voltage module has a vertical lead wire terminal block. The UVT is not provided with a cassette. *6 SLT to be used when three or more accessories are installed on the left pole is manufactured to order. Remarks: 1. The encircled numbers indicate the order of installation. 2. TBM can be installed regardless of the number of installed AL, AX, SHT UVT. (*6) (*5) (*4) (*5) (*6) (*4) (*5) (*6) (*4) (*5) (*6) (*1)

69 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Table 7 Table of maximum number of internal accessories Model AL AX SHT or UVT MCCB Number of poles ELCB AL AX (stard) switches Accessory AL + AX NF50-SVFU NF-CVFU NF50-SVFU NF-CVFU NF125-SVU NF125-HVU NF250-SVU NF250-HVU NF225-CWU NF400-SWU NF400-HWU NF630-SWU NF630-HWU 2 poles 3 poles 2 or 3 poles 3 poles 3 poles 3 poles 2 poles 3 poles 3 poles S (*1) (*6) (*1) (*3) (*6) (*1) (*3) (*1) (*1) (*3) (*1) (*3) (*1) (*6) (*1) 1 1 (*2) (*2) Left pole Hle of circuit breaker Right pole AL AX SHT or UVT (*4) (*4) 3 4 NV50-SVFU TBM are cassette type accessories. NV50-SVFU NV-CVFU (*6) (*6) (*2) 1 2 Outgoing direction of lead wires NV125-SVU NV125-HVU NV250-SVU NV250-HVU 1 2 (*2) AL + AX + SHT or UVT SHT or UVT (*1) (*6) (*1) (*1) (*6) (*1) (*1) (*1) (*1) (*3) (*4) (*5) (*1) (*3) (*4) (*5) (*1) (*3) (*4) (*5) (*1) (*3) (*4) (*5) SHT AL + AX + or UVT (*1) (*6) (*1) (*1) (*1)(*3) (*4)(*5) (*1)(*3) (*4)(*5) TBM (*7) (*7) (*7) Notes *1 When UVT is provided, the UVT voltage module will come in the vertical lead wire terminal block type. (SHT does not have a voltage module.) *2 SHT cannot be installed. *3 SHT UVT are normally installed on the right pole side. If you intend to install them on the left pole side, specify so. *4 In the case where three or more accessories are installed on the left pole side AL, AX or AL AX are installed on the pole on which SLT, SHT or UVT is installed, the SLT will be manufactured to order. *5 When AL, AX or AL AX are installed on the pole on which UVT is installed, the UVT voltage module must be installed separately. *6 UVT of NF50-SVFU NV50-SVFU are not provided with cassettes. *7 The stard type is provided with SLT. Only in the case of 24 V DC, specify the control voltage. Remarks: 1. The encircled numbers indicate the order of installation. 2. AL AX for minute load can be manufactured to order. (These switches have been certified only by UL CSA. They have not been certified by TUV.) Other

70 730 Low-Voltage Internal Other MDU Table -1 Table of maximum number of internal accessories Model Number of poles switch Accessory AL AX SHT UVT AL + AX AL + SHT AX + SHT AL + AX + SHT AL + UVT AX + UVT AL + AX + UVT PAL EPAL TI NF400-SEP with MDU NF400-HEP with MDU Left pole 3 or 4 poles S are cassette type accessories. NF600-SEP with MDU NF600-HEP with MDU NF00-SEP with MDU NF00-HEP with MDU (*2) (*2) (*3) (*4) (*1) (*1) (*2) (*1) (*2) (*1) (*2) (*1) (*3) (*4) (*5) (*1) (*3) (*4) (*5) (*1) (*3) (*4) (*5) Notes *1 In the case where three or more accessories are installed on the left pole side AL, AX or AL AX are installed on the pole on which SLT, SHT or UVT is installed, the SLT will be manufactured to order. *2 SHT UVT are normally installed on the right pole side. If you intend to install them on the left pole side, specify so. (The reset preventing UVT must be installed on the left pole side.) *3 The UVT voltage module is installed externally. UTV is not provided with a cassette. *4 UVT is normally installed on the right pole. If you intend to install it on the left pole, specify so. *5 When AL, AX or AL AX are installed on the pole on which UVT is installed, the UVT voltage module must be installed separately. *6 The stard model has a terminal block. A 5-VA control power supply (compatible with to 240 V AC/DC) is required. (In this case, another internal accessory cannot be installed on the right pole.) Remark: 1. The encircled numbers indicate the order of installation (*6) (*6) (*6) With contact outputs for PAL OAL Hle of circuit breaker Right pole AL for AX for AL AX transmission with MDU transmission with MDU SHT or UVT TI PAL Outgoing direction of lead wires (*1) (*1) (*3) (*4) (*1) (*1) (*2) (*1) (*2) (*1) (*2) (*1) (*3) (*4) (*5) (*1) (*3) (*4) (*5) (*1) (*3) (*4) (*5) (*6) With contact outputs for PAL OAL

71 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Table -2 Table of maximum number of internal accessories Model Number of poles switch Accessory AL for transmission with MDU (*1) AX for transmission with MDU (*1) AL + AX for transmission with MDU (*1) AL + AX + AL for transmission with MDU (*1) AL+AX + AX for transmission with MDU (*1) AL + AX + AL + AX for transmission with MDU (*1) NF400-SEP with MDU NF400-HEP with MDU Left pole 3 or 4 poles S Hle of circuit breaker Right pole NF600-SEP with MDU NF600-HEP with MDU NF00-SEP with MDU NF00-HEP with MDU AL for AX for AL AX transmission with MDU transmission with MDU SHT or UVT TI Note *1 To transmit signals from AL, AX or AL AX, AL /or AX for transmission with the MDU are installed on the left pole side. In this case, the lead wires of AL /or AX for transmission with the MDU installed on the left pole side cannot be drawn out to the outside or fitted to the terminal block. Model Number of poles switch Accessory AL AX AL + AX SHT or UVT AL + SHT AX + SHT AL + AX + SHT AL + UVT AX + UVT AL + AX + UVT AL for transmission with MDU (*3) AL for transmission with MDU AX (*3) AL for transmission with MDU AL + AX (*3) AL for transmission with MDU AL + AX + AL (*3) AL for transmission with MDU AL + AX + AX (*3) AL for transmission with MDU AL + AX + AL + AX (*3) NF250-SEV with MDU NF250-HEV with MDU 3 or 4 poles S (*1) 1 2 (*2) (*2) (*2) (*2) (*2) (*2) (*2) Left pole Hle of circuit breaker Right pole PAL are cassette type accessories. Outgoing direction of lead wires Notes *1 The second AX can be installed in place of the AL on the left pole side. When placing an order, specify the incorporation of the switches in the body. *2 When UVT is provided, the UVT voltage module will come in the vertical lead wire terminal block type. (SHT does not have a voltage module.) *3 To transmit signals from AL, AX or AL AX, AL /or AX for transmission with the MDU are installed on the left pole side. In this case, the lead wires of AL /or AX for transmission with the MDU installed on the left pole side cannot be drawn out to the outside or fitted to the terminal block. In the case of 225A frame circuit breakers, AL for transmission with the MDU must be installed for fault current measurement. Remark: 1. The encircled numbers indicate the order of installation. AL AX AL for transmission with MDU PAL are cassette type accessories. AX for transmission with MDU SHT or UVT Outgoing direction of lead wires Other

72 732 Low-Voltage Internal Cassette Type The internal accessories for major models having a frame size from 30 to 00 A come in cassettes, they can be installed to removed from circuit breakers by the user. Some cassette type accessories have lead wires drawn out, others have vertical lead wire terminal blocks (SLT). (These parts are supplied by 10 pieces for frame size from 30 to 250 A or by 1 piece for frame size from 400 to 00 A.) Applicable models kinds of cassette type accessories MCCB ELCB Model Alarm switch (AL) Auxiliary switch (AX) Shunt tripping device (SHT) Undervoltage tripping device (UVT) NF63-CV~NF250-CV, NF32-SV~NF250-SV NF63-HV~NF250-HV NF125-SGV~NF250-SGV, NF125-LGV~NF250-LGV NF125-HGV~NF250-HGV NF125-SEV, NF250-SEV, NF125-HEV, NF250-HEV NF125-RGV, NF250-RGV, NF125-UV, NF250-UV NF-CVFU, NF125-SVU/HVU, NF250-SVU/HVU NF50-SVFU, NF400-CW, NF630-CW, NF00-CEW NF400-SW, NF630-SW, NF400-SEW~NF00-SEW NF00-SDW, NF400-HEW~NF00-HEW NF400-REW~NF00-REW, NF400-UEW, NF00-UEW NF400-SWU/HWU, NF630-SWU/HWU NV63-CV~NV250-CV, NV32-SV~NV250-SV NV63-HV~HV250-HV NV125-SEV, NV250-SEV, NV125-HEV, NV250-HEV NV-CVFU, NV125-SVU/HVU, NV250-SVU/HVU NV50-SVFU, NV400-CW, NV630-CW NV400-SW, NV630-SW, NV400-SEW~NV00-SEW NV400-HEW~NV00-HEW, NV400-REW Procedure for installing cassette type accessories Other 1. Press the trip button (PTT) to trip the circuit breaker. (*1) 2. Loosen the cover screws. 3. Open the cover. 4. Install the cassette type accessory. (*2) Notes *1 When installing any cassette type accessory, set the circuit breaker to the tripped state. *2 If the inner lid or another accessory has been installed, remove it before installing the accessory. When any circuit breaker supplied with the inner lid is used without an accessory, fit the inner lid without fail. Failure to do so may affect the short-circuiting performance. Models with inner lid: NF125-SV, NF125-HV, NF125-UV NV125-SV, NV125-HV NF250-SV, NF250-HV NV250-SV, NV250-HV NF125-SVU, NF125-HVU, NV125-SVU, NV125-HVU NF250-SVU, NF250-HVU, NV250-SVU, NV250-HVU Cautions when installing 5. Close the cover, tighten the screws. NF250-SEV, NF250-HEV, NF250-UV NV250-HEV NF125-SEV, NF125-HEV NV125-SEV, NV125-HEV NF400-REW, NF400-UEW NF630-REW, NV400-REW NF00-HEW, NF00-REW, NF00-UEW NV00-HEW NF630-SWU, NF630-HWU Before installing or removing any cassette type accessory, set the circuit breaker accessories to the no-voltage state. Never install a cassette type accessory while the hle is in the ON or OFF position. Doing so may damage the accessory. When installing an accessory with lead wires drawn out, apply the supplied nameplate to the circuit breaker side face. When installing an accessory with lead wires drawn out for a frame size of 400 to 00 A, secure the lead wires along the circuit breaker side face with the supplied lead wire retainers.

73 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Type name Table 9-1 NF50-SVFU MCCB Model NF32-SV, NF63-CV, NF63-SV, NF63-HV NF125-CV, NF125-SV, NF125-HV NF125-SGV, NF125-LGV, NF125-HGV NF160-SGV, NF160-LGV, NF160-HGV NF125-SEV, NF125-HEV NF125-RGV, NF125-UV NF250-CV, NF250-SV, NF250-HV NF250-SGV, NF250-LGV, NF250-HGV NF250-SEV, NF250-HEV NF250-RGV, NF250-UV NV50-SVFU ELCB NV32-SV, NV63-CV NV63-SV, NV63-HV NV125-CV, NV125-SV NV125-HV NV125-SEV, NV125-HEV NV250-CV, NV250-SV NV250-HV NV250-SEV, NV250-HEV pole For right pole For left pole For left pole For right pole For left pole For left pole AL AX AL+AX SHT UVTN or UVTS AL-03SVU AL-03SVURS AX-03SVU AX-03SVURS ALAX-03SVU ALAX-03SVURS AL-03SVU AX-03SVU ALAX-03SVU AL-03SVULS AX-03SVULS ALAX-03SVULS AL-05SV AL-05SVRS AL-05SV AL-05SVLS AX-05SV ALAX-05SV AX-05SVRS ALAX-05SVRS AX-05SV AX-05SVLS ALAX-05SV ALAX-05SVLS SHTA240-03SVUR SHTA440-03SVUR SHTD-03SVUR SHTA240-03SVURS SHTA440-03SVURS SHTD-03SVURS SHTA240-03SVUL SHTA440-03SVUL SHTD-03SVUL SHTA240-03SVULS SHTA440-03SVULS SHTD-03SVULS SHTA240-05SVR SHTA550-05SVR SHTD125-05SVR SHTA240-05SVRS SHTA550-05SVRS SHTD125-05SVRS SHTA240-05SVL SHTA550-05SVL SHTD125-05SVL SHTA240-05SVLS SHTA550-05SVLS SHTD125-05SVLS UVTNAD130-05SVR UVTSAD130-05SVR UVTNA250-05SVR UVTSA250-05SVR UVTNA40-05SVR UVTSA40-05SVR UVTNAD130-05SVRS UVTSAD130-05SVRS UVTNA250-05SVRS UVTSA250-05SVRS UVTNA40-05SVRS UVTSA40-05SVRS UVTNAD130-05SVL UVTNA250-05SVL UVTNA40-05SVL UVTNAD130-05SVLS UVTNA250-05SVLS UVTNA40-05SVLS UVTSAD130-05SVL UVTSA250-05SVL UVTSA40-05SVL UVTSAD130-05SVLS UVTSA250-05SVLS UVTSA40-05SVLS NF-CVFU NF125-SVU/HVU NF250-SVU/HVU NF400-CW, NF400-SW, NF400-SEW NF400-HEW, NF400-REW, NF400-UEW NF630-CW, NF630-SW, NF630-SEW NF630-HEW, NF630-REW NF00-CEW, NF00-SDW, NF00-SEW NF00-HEW, NF00-REW, NF00-UEW NV-CVFU NV125-SVU/HVU NV250-SVU/HVU NV400-CW, NV400-SW NV400-SEW, NV400-HEW NV400-REW NV630-CW, NV630-SW NV630-SEW, NV630-HEW NV00-SEW, NV00-HEW For right pole For left pole For left pole For right pole (2, or 3 poles) For right pole (4 poles) For left pole (2, 3 or 4 poles) For left pole (2, 3 or 4 poles) AL-05SVU AL-05SVURS AX-05SVU AX-05SVURS ALAX-05SVU ALAX-05SVURS AL-05SVU AX-05SVU ALAX-05SVU AL-05SVULS AX-05SVULS ALAX-05SVULS AX-4SW AX-4SWRS AX2-4SWRS AL-4SWL AL-4SWLS AL2-4SWLS AX-4SW AX-4SWLS AX2-4SWLS ALAX-4SWL ALAX-4SWLS AX-4SWU AX-4SWURS AX2-4SWURS SHT-4SW SHT-4SWRS SHT-4SWRFS SHT-SWRFS SHT-4SW SHT-4SWLS SHT-4SWU SHT-4SWURS NF400-SWU, NF400-HWU For right pole NF630-SWU, NF630-HWU For left pole AL-4SWUL AX-4SWUL ALAX-4SWUL SHT-4SWU Remarks: 1. For the possibility of installation of accessories the installation pole, refer to the tables of maximum numbers on pages 727 to AL AX for minute load can be manufactured to order. 3. Corrosion-proof cassette type AL AX are not available. When the circuit breaker body is exposed to class 1 tropicalization, class 2 tropicalization, reinforced corrosion resistance treatment or class 2 heat resistance treatment, place an order for the circuit breaker including the accessories. 4. Cassette type accessories with SLT for right pole cannot be installed to circuit breakers. with SLT for right pole to be used in circuit breakers are manufactured to order. 5. Cassette type accessories with SLT cannot be installed to flush plate type circuit breakers. 6. Cassette type accessories (AL, AX SHT) cannot be installed to circuit breakers with MG. 7. It is impossible to install a combination of a cassette type accessory with lead wires drawn out that with SLT or a combination of cassette type accessories with SLT on the same pole.. It is impossible to install the cassette type AL or AX to the pole to which UVT has been installed. 9. AX SHT with lead wires drawn out for frame size from 400 to 00 A can be installed to any of the right left poles. 10. When installing more than one AL or AX with lead wires drawn out for frame size from 400 to 00 A to one side, install the necessary number of the accessories for one piece. The lead wires from the circuit breaker vary in length depending on the installation position. 11. Install the cassette accessories for frame size from 400 to 00 A starting from the outside of the installation positions. For the installation positions, see the installation positions shown in the following table. 12. When three pieces of more of AL AX are installed on a circuit breaker with a frame size 400 to 00 A, the AL AX with SLT are manufactured to order. SHTA240-05SVUR SHTA550-05SVUR SHTD125-05SVUR SHTA240-05SVURS SHTA550-05SVURS SHTD125-05SVURS SHTA240-05SVUL SHTA550-05SVUL SHTD125-05SVUL SHTA240-05SVULS SHTA550-05SVULS SHTD125-05SVULS UVTNAD130-05SVUR UVTNA250-05SVUR UVTNA40-05SVUR UVTNAD130-05SVURS UVTNA250-05SVURS UVTNA40-05SVURS UVTNAD130-05SVUL UVTNA250-05SVUL UVTNA40-05SVUL UVTNAD130-05SVULS UVTNA250-05SVULS UVTNA40-05SVULS positions of cassette type accessories for 400 to 00 A frames positions Table 9-2 positions of cassette type accessories L1 L2 L3 L4 ON OFF R4 R3 R2 R1 Frame (A) Accessory positions AL AX L1 L2 L3 R2 R1 L1 L2 L3 L4 R4 R3 AL + AX SHT (*1) UVTSAD130-05SVUR UVTSA250-05SVUR UVTSA40-05SVUR UVTSAD130-05SVURS UVTSA250-05SVURS UVTSA40-05SVURS UVTSAD130-05SVUL UVTSA250-05SVUL UVTSA40-05SVUL UVTSAD130-05SVULS UVTSA250-05SVULS UVTSA40-05SVULS * only for (NV-C, S H), Alarm (NF-Z) single-phase 3-wire circuits (NF-N NV-N) cannot be installed to R1, R2, R3 or R4. Note *1 It is impossible to simultaneously install AX on R2 SHT on R3 or R4. R2 (*1) R1 Other

74 734 Low-Voltage Internal Other Interpretation of type name (1) Alarm switch Auxiliary switch AL AX Kind of accessory Alarm switch Auxiliary switch Number of accessories to be installed When installing more than one AL or AX with SLT, specify the number. (2) Shunt tripping device Undervoltage tripping device Kind of accessory SHT Shunt tripping device UVTN (*1) Undervoltage UVTS (*2) tripping device A240 A440 A40 A550 D D125 Blank AD130 A250 A40 Voltage (SHT) AC-240V AC30-440V AC30-40V AC30-550V DCV DC-125V AC-450/DC-200V Shunt Trip (SHT) Coil ratings (stard) Table 10-1 NF50-SVFU NV50-SVFU AL 2 4 SV (or SW) L S B Ampere frame For 30 to 250A frames For 400 to 00A frames Coil ratings (list of available special voltage coils) Table Voltage (UVTN or UVTS) Switching between to 130 V AC to 130 V DC AC V AC30-40V Model NF32-SV, NF63-CV/SV/HV, NF125-SGV/LGV/HGV NF160-SGV/LGV/HGV, NF125-CV/SV/HV/SEV/HEV/RGV/UV NF250-CV/SV/HV/SEV/HEV/RGV/UV NF250-SGV/LGV/HGV NV32-SV, NV63-CV/SV/HV NV125-CV/SV/HV/SEV/HEV, NV250-CV/SV/HV/SEV/HEV NF-CVFU, NF125-SVU/HVU, NF250-SVU/HVU NV-CVFU, NV125-SVU/HVU, NV250-SVU/HVU NF225-CWU NF400-CW/SW/SEW/HEW/REW/UEW NF630-CW/SW/SEW/HEW/REW NF00-CEW/SDW/SEW/HEW/REW/UEW NV400-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW NV00-SEW/HEW, NF400-SWU/HWU, NF630-SWU/HWU NF0-SEW, NF1250-SEW/SDW NF1600-SEW/SDW position R Right pole, 2 or 3 poles RF Right pole, 4 poles L Left pole Blank Right left SHT A1 1 SV (or SW) R S Ampere frame 05 For 30 to 250A frames 4 For A frames For 00A frames (3P) For 00A frames (4P) position R Right pole, 2 or 3 poles RF Right pole, 4 poles L Left pole Blank Right left Kind of switch Blank Stard B Minute load With SLT (vertical lead wire terminal block) (with lead wires drawn out unless otherwise specified) With SLT (vertical lead wire terminal block) (with lead wires drawn out unless otherwise specified) Notes *1 The circuit breaker cannot be reset if voltage is not applied to UVTN. (Non-reset type UVT) *2 The circuit breaker can be reset even if voltage is not applied to UVTS. (Reset type UVT) Provision of coil burnout preventing switch Provided Voltage (V) AC DC AC DC-125 AC DC-125 Compatible with to 450 V AC to 200 V DC AC DC Input (VA) (*1) AC DC V 20 V V 50 30V V V Operating time (*2) (ms) or less Notes *1 Ensure that the voltage of the operating power supply for SHT is not dropped below the allowable operating voltage (% of the rated minimum voltage value) by the input power. *2 The operating time is the time from when the rated voltage is applied to the shunt tripping device until the main contact of the circuit breaker starts opening. Remark: 1. The accessory is usable at 50 Hz 60 Hz. Model Compatible VAC VDC with AC/DC NF32-SV, NF63-CV/SV/HV NF125-CV/SV/HV/SEV/HEV/RGV/UV NF125-SGV/LGV/HGV, F160-SGV/LGV/HGV NF250-CV/SV/HV/SEV/HEV/RGV/UV NF250-SGV/LGV/HGV NV32-SV, NV63-CV/SV/HV NV125-CV/SV/HV/SEV/HEV NV250-CV/SV/HV/SEV/HEV NF-CVFU, NF125-SVU/HVU, NF250-SVU/HVU NV-CVFU, NV125-SVU/HVU, NV250-SVU/HVU NF225-CWU NF400-CW/SW/SEW/HEW/REW/UEW NF630-CW/SW/SEW/HEW/REW NF00-CEW/SDW/SEW/HEW/REW/UEW NV400-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW NV00-SEW/HEW, NF400-SWU/HWU, NF630-SWU/HWU NF0-SEW, NF1250-SEW/SDW NF1600-SEW/SDW

75 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Undervoltage Trip (UVT) (1) for UVT coil ratings Table 11 Model NF50-SVFU NV50-SVFU NF32-SV, NF63-CV/SV/HV/HRV NF125-CV/SV/HV/RGV/SEV/HEV/UV NF125-SGV/LGV/HGV, NF160-SGV/LGV/HGV NF250-CV/SV/HV/RGV/SEV/HEV/UV NF250-SGV/LGV/HGV NV32-SV, NV63-CV/SV/HV NV125-CV/SV/HV/SEV/HEV NV250-CV/SV/HV/SEV/HEV NF-CVFU, NF125-SVU/HVU, NF250-SVU/HVU NV-CVFU, NV125-SVU/HVU, NV250-SVU/HVU NF400-CW/SW/SEW/HEW/REW/UEW NF630-CW/SW/SEW/HEW/REW NF00-CEW/SDW/SEW/HEW/REW/UEW NV400-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW NV00-SEW/HEW NF0-SEW, NF1250-SEW NF1600-SEW NF400-SWU/HWU, NF630-SWU/HWU NF225-CWU Reset type Specification Non-reset type (2) Reset type non-reset type UVT Coil ratings Voltage (V) Stard voltage Special voltage AC/DC24V AC/DC4V Switching between to to 130 AC Switching between 200 to to 250 AC Switching between 30 to to 40 AC Switching between 110 DC Reset type (Refer to Table 12.) The reset type UVT has a structure which does not trip a circuit breaker even if the UVT coil is not excited when the circuit breaker hle is in the OFF or reset position. Therefore, it keeps the circuit breaker in the reset state even if the coil is not excited when the breaker is reset electrically. When the coil in the unexcited state is turned on, the circuit breaker is normally tripped. However, the major contacts of some models of circuit breakers may instantaneously close, or, on circuit breakers with AX, the AX switches may instantaneously change over. For electrical interlock, use a non-reset type UVT. Non-reset type (Refer to Table 12.) When the UVT coil is not excited, the circuit breaker cannot be set to the off state even if the circuit breaker is tried to be reset from the tripped state. When the coil exciting voltage restores to the reference voltage or more, the circuit breaker can be reset to the off state. (3) Time delay UVT l This type of UVT has a time delay in operation. l It can prevent operation upon occurrence of instantaneous power failure. (*4) AC/DC-130V AC V AC30-40V AC/DC24V AC/DC4V AC V (*1) Switching between 24/4 AC Switching between 500 to 550/600 AC Switching between 24/4DC Switching between 110/125DC Switching between (*3) 24/4 AC Switching between 24/4DC Switching between 110/125DC Notes *1 Some special voltage models vary in voltage range. *2 The operating time is the time from when the undervoltage tripping device is set to the no-voltage state until the main contact starts opening. *3 The accessory is usable at 50 Hz 60 Hz. *4 If UVT is turned on without excitation, the circuit breaker instantaneously opens immediately trips. *5 Only for installation on the left pole Table 12 UVT module type name U-05W U-30W Time delay Switching among 0.1, s Switching among 0.5, 1 3 s (*5) (*4) Voltage (V) Stard voltage Special voltage AC24/4 AC120/200240/30450 AC30450/460550/ AC220250/30450/ (Compatible with 50 Hz 60 Hz) (Compatible with 50 Hz 60 Hz) DC24/4 DC110 AC120/200240/30450 AC220250/30450/ (Compatible with 50 Hz 60 Hz) (*3) (*3) Input (VA) 5 Operating time (*2) (ms) 5 30 or less or less Other

76 736 Low-Voltage Internal (4) Structure of UVT The UVT mechanical unit is installed in a circuit breaker, the UVT voltage module is installed on the outside of the circuit breaker. When the voltage drops, the UVT voltage module detects the voltage drop, the UVT mechanical unit trips the circuit breaker. The UVT voltage module has a vertical lead wire terminal block is normally installed on the body. The external module will be manufactured to order. loutline drawing Terminal cover fixing hole x10, tapping screw (to be prepared by user) f f Terminal screw M3.5 Tightening torque: 0.9 to 1.2 N m 4 (Terminal cover) 57 Terminal cover Fig. 1 Terminal screw M3.5 Tightening torque: 0.9 to 1.2 N m 92.5 (Terminal cover) B 0 A A C C 90 D D Terminal cover (Terminal cover) 4 (Terminal cover) Terminal screw M3.5 Tightening torque: 0.9 to 1.2 N m Fig Terminal cover f4.5 f Terminal cover fixing hole 3x10, tapping screw (to be prepared by user) Terminal cover fixing hole x10, tapping screw 10 5 (to be prepared by user).5 Terminal cover fixing hole 3x10, tapping screw (to be prepared by user) Terminal cover Fig B Terminal screw M3.5 Tightening torque: 0.9 to 1.2 N m Fig. 4 3 Other lexamples of connection Examples of connection Terminal symbols Table 13 on right pole side Model Short-circuit protecting device, such as fuse D1/P1 D2/P2 J1/UC1 J2/UC2 NF50-SVFU NF32-SV, NF63-CV/SV/HV NF-CVFU NF125-CV/SV/HV NF125-SVU/HVU NF125-UV NF125-SEV/HEV/RGV, NF250-CV/SV/HV/RGV/SEV/HEV NF125-SGV/LGV/HGV, NF160-SGV/LGV/HGV NF250-SGV/LGV/HGV NF250-SVU/HVU NF250-UV NF225-CWU NF400-CW/SW/SEW/HEW/REW NF630-CW/SW/SEW/HEW/REW, NF400-SWU/HWU NF400-UEW(3P) NF00-CEW/SDW/SEW/HEW/REW, NF630-SWU/HWU NF400-UEW(4P), NF00-UEW NF0-SEW, NF1250-SEW, NF-1600-SEW Control power supply terminal (COM) Control power supply terminal (rated voltage) UVT coil connecting terminal UVT coil connecting terminal Remarks: 1. When the UVT voltage module is installed on the body (stard), the UVT is supplied with J1/UC1 J2/UC2 terminals connected with the UVT coil. 2. When the UVT is installed on the left pole side, the UVT module terminal positions are reversed (on the power supply load sides). Carefully connect the terminals. Examples of connection Fig. 5 Fig. 6 Reference drawing Fig. 1 Fig. 5 Fig. 3 Fig. 6 Variable dimensions A B Short-circuit protecting device, such as fuse Terminal symbols D1/P1 D2/P2 D3/P3 J1/UC1 J2/UC2 Table 14 on left pole side Model NV125-CV/SV/HV NV125-SEV/HEV, NV250-CV/SV/HV/SEV/HEV NF400-CW/SW/SEW/HEW/REW NF630-CW/SW/SEW/HEW/REW NV400-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW NF400-ZCW/ZSW/ZEW NF400-SWU/HWU NF400-UEW(3P) NF00-CEW/SDW/SEW/HEW/REW NV00-SEW/HEW, NF630-SWU/HWU NF400-UEW(4P), NF00-UEW Control power supply terminal (COM) Control power supply terminal (rated voltage Lo) Control power supply terminal (rated voltage Hi) UVT coil connecting terminal UVT coil connecting terminal Remarks: 1. When the UVT is used at the rated voltage Lo, connect the control voltage to D1/P1 D2/P2 terminals. When the UVT is used at the rated voltage Hi, connect the control voltage to D1/P1 D3/P3 terminals. (Ex.) to 110/120 to 130 V AC (Rated voltage Lo/rated voltage Hi) 2. When the UVT voltage module is installed on the body (stard), the UVT is supplied with J1/UC1 J2/UC2 terminals connected with the UVT coil. 3. When the UVT is installed on the left pole side, the UVT module terminal positions are reversed (on the power supply load sides). Carefully connect the terminals. Reference drawing Fig. 2 Fig. 5 Fig. 4 Fig. 6 Variable dimensions C D

77 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Lead Wire Drawing Lead wire lateral drawing Available to all models Note *1 Except for BH, BH-P, BH-S, BH-PS, BH-D6, BH-D10, BH-DN, BV-D, BV-DN KB-D. Lead wires drawing to load Table 15 NF30-CS Model applicable to lead wire drawing to load for lead wires Table 16 (only front connection type) Applicable model Kind of lead wire Lead wire thickness Lead wire length Example of ring mark NF30-CS 0.4mm 2 9/ALa (Red), 96/ALb (Blue) 95/ALc (Gray), 14/AXa (Brown) 12/AXb (Black), 11/AXc (White) 0A frame or above Heat-resistant 0.75mm 2 450mm C1/S1 (Red), C2/S2 (Red) wire J1/UC1 (White), J2/UC2 (White) A terminal symbol is 30 to 00A frames except 0.5mm 2 indicated on each lead above models wire with a ring mark. Remark: 1. Although the following models are applicable to lead wires drawn laterally, they are normally applicable to installation in close contact with the circuit breaker side faces. (The circuit breaker side faces have grooves.) NF32-SV, NF63-CV/SV/HV~NF250-CV/SV/HV/UV NF125-SEV/HEV, NF250-SEV/HEV, NF125-RGV NF250-RGV, NF125-SGV/LGV/HGV~NF250-SGV/LGV/HGV NV32-SV, NV63-CV/SV/HV~NV250-CV/SV/HV NV125-SEV/HEV, NV250-SEV/HEV NF50-SVFU, NF-CVFU, NF125-SVU/HVU, NF250-SVU/HVU, NF225-CWU NV-CVFU, NV125-SVU/HVU NV250-SVU/HVU (When a model among the above models has accessories installed on the right pole side, the lead wires are 400 mm long.) Lead Wire Terminal Block (1) Vertical lead wire terminal block (SLT) The lead wire terminal blocks for plug-in terminal blocks are available (P-LT). The drilling size of these terminal blocks differs from the stard size. Consult us for details. For a flush plate type circuit breaker, a terminal block will be installed on the circuit breaker rear face. (Specify as FP-LT.) Note *1 When the circuit breaker body is equipped with internal accessories electrical operation device of motor-driven type (2) or spring charge type (2), the circuit breaker is normally provided with a lead wire terminal block. MCCB D B A C Terminal cover (transparent) Terminal screw M3.5 J F 12.5 E Table 17-1 Table of variable dimensions Model NF30-CS (*1) NF32-SV, NF63-CV/SV/HV NF125-CV/SV/HV NF125-UV NF250-UV NF125-SEV/HEV/RGV, NF250-CV/SV/HV/SEV/HEV/RGV NF125-SGV/LGV/HGV, NF160-SGV/LGV/HGV NF250-SGV/LGV/HGV NF50-SVFU NF-CVFU NF125-SVU/HVU NF225-CWU NF400-CW/SW/SEW/HEW/REW, NF400-SWU/HWU NF630-CW/SW/SEW/HEW/REW NF00-CEW/SDW/SEW/HEW/REW, NF630-SWU/HWU NF0-SEW, NF1250-SEW, NF1600-SEW NF400-UEW(3P) NF400-UEW(4P), NF00-UEW A B C D E Note *1 The terminal positions are different from those shown in the left figure. Consult us for details. Remark: 1. Terminal screw tightening torque: M to 1.2 N m (*1) (*1) F G H J H G 13.5 Other

78 73 Low-Voltage Internal ELCB D B A C Terminal cover (transparent) Terminal screw M3.5 M L K 1 J terminal SLT B F H E G SLT for installing three or more internal accessories on the left pole side A 75 Terminal cover (transparent) Terminal screw M Table 17-2 Table of variable dimensions Model A B C D E F G H J K L M NV50-SVFU NV32-SV, NV63-CV/SV/HV NV-CVFU NV125-CV/SV/HV NV125-SVU/HVU NV125-SEV/HEV, NV250-CV/SV/HV/SEV/HEV NV250-SVU/HVU NV400-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW NV00-SEW/HEW (*1) Note *1 The terminal positions are different from those shown in the left figure. Consult us for details. Remarks: 1. Terminal screw tightening torque: M to 1.2 N m 2. The lead wire terminal block for TBL is provided on the right pole side. However, the lead wire terminal blocks for TBL of NV30-FA NV50-FA are provided on the left pole side. Table 17-3 Model MCCB ELCB A NF400-CW/SW/SEW NV400-CW/SW/SEW NF400-HEW/REW NV400-HEW/REW NF630-CW/SW/SEW NV630-CW/SW/SEW/HEW NF630-HEW/REW 20 NF400-UEW(3P) 117 NF00-CEW/SDW/SEW NF00-HEW/REW NV00-SEW/HEW 20 NF400-UEW(4P), NF00-UEW 117 NF0-SEW, NF1250-SEW NF1600-SEW 35 Remark: 1. The terminal positions are different from those shown in the left figure. Consult us for details. B Other Test Button Module (TBM) l The test button is kept pressed while control input voltage is applied to the button. (When ELCB of time delay type is used, apply voltage for 2 seconds or more.) l The test button module is supplied with voltage through a circuit isolated from the main circuit. It can share the control sequence with SHT of a molded case circuit breaker. l Unlike TBL, the test button modules can be connected in parallel. l The module is normally provided with a vertical lead wire terminal block (SLT). Table 1 Model Control input Rated voltage (V) NV32-SV NV63-CV/SV/HV NV125-CV/SV/HV NV125-SEV/HEV NV250-CV/SV/HV/SEV/HEV NV50-SVFU NV-CVFU NV125-SVU/HVU NV250-SVU/HVU NV400-CW/SW NV630-CW/SW NV400-SEW~NV00-SEW NV400-HEW~NV00-HEW NV400-REW Compatible with to 240 AC to 240 DC (DC24) (*1) Control input (VA) 1.5 VA or less 1 VA or less Reference drawing Fig. 1 Fig. 2 Note *1 Unless otherwise specified, the module will be manufactured for to 240 V AC to 240 V DC. In the case of 24 V DC, specify the voltage. Remark: 1. The length of the lead wires to be connected to TBM1 2 shall be m or more. 1 TBM2 TBM (10.5) On a single-phase 3-wire Fig circuit breaker with neutral Fig. 2 pole protection, this terminal is used as an overvoltage detection terminal. For a flush plate type with 250A frame or below, the external dimensions of the flush plate type differ from the stard dimensions TBM2 TBM (10.5) 92 (Terminal cover) On a single-phase 3-wire circuit breaker with neutral pole protection, this terminal is used as an overvoltage detection terminal.

79 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Pre-Alarm Module (PAL) The pre-alarm is a function to output an alarm when the load current exceeds the preset current value. It is helpful in securing continuous power supply preventive maintenance. It can be fitted to electronic circuit breakers with a frame size from 125 to 1600 A. j A frames d Pre-alarm module (PAL module) The stard modules have SLT. Other internal accessories cannot be installed on the right pole side. A control power supply (compatible with to 240 V AC DC) is necessary. The control power supply voltage range is 5 to 246 V AC/DC, the required volt-ampere is 5 VA. Table 19-1 Model Switching capacity Contact output (1a) Resetting method AC125V 2A DC 30V 2A AC250V 2A DCV 0.3A NF125-SEV NF125-HEV NF250-SEV NF250-HEV NV125-SEV NV125-HEV NV250-SEV NV250-HEV Pre-alarm characteristics Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s Pre-alarm current Ip Inx ( ) ±10% 60 Pre-alarm operating time Tp TL Tp= ±20% 2 (at200%) Pre-alarm operating characteristics Long time delay operating time, TL s ±20% (at 200%) Current (% to rated current In) Dimensional drawing of pre-alarm module Applicable models NF125-SEV, NF250-SEV NV125-SEV, NV250-SEV Pre-alarm setting knob Pre-alarm operation indicating LED Reset button Applicable models NF125-HEV, NF250-HEV NV125-HEV, NV250-HEV Press the reset button, or turn off the control power supply. Pre-alarm setting knob Pre-alarm operation indicating LED d Pre-alarm LED indication When the load current exceeds the preset current value, the LED lamp on the pre-alarm module front panel starts blinking. When the prealarm output is given, the lamp stops blinking turns on. d Pre-alarm current setting (IP setting) The pre-alarm current can be set to the rated current In 0.7, 0.75, 0., 0.5, 0.9, 0.95 or 1.0 with the knob on the pre-alarm module front panel. j 400 A frame or above d Solid state relay (SSR) output (PAL lead) The lead wires are drawn out. On the right pole side, only internal accessories with lead wires drawn out can be installed. A control power supply is unnecessary. Table 19-2 Model NF400-SEW NF400-HEW NF400-REW NF400-UEW NF630-SEW NF630-HEW NF630-REW NF00-CEW NF00-SEW NF00-HEW NF00-REW NF00-UEW NF0-SEW NF1250-SEW NF1600-SEW NV400-SEW NV400-HEW NV400-REW NV630-SEW NV630-HEW NV00-SEW NV00-HEW d Pre-alarm module (PAL module) The stard modules have SLT. Other internal accessories cannot be installed on the right pole side. A control power supply (compatible with to 200 V AC) is necessary except for NF-ZEW. The control power supply voltage range is 0 to 242 V AC, the required volt-ampere is 10 VA. Table 19-3 Model NF400-SEW NF400-HEW NF400-REW NF400-UEW NF630-SEW NF630-HEW NF630-REW NF00-CEW NF00-SEW NF00-HEW NF00-REW NF00-UEW NF0-SEW NF1250-SEW NF1600-SEW NV400-SEW NV400-HEW NV400-REW NV630-SEW NV630-HEW NV00-SEW NV00-HEW Pre-alarm characteristics 25 Terminal screw M3.5 drawing of pre-alarm module Reset button Terminal arrangement NF125-SEV NF125-HEV NF250-SEV NF250-HEV NV125-SEV NV125-HEV NV250-SEV NV250-HEV Control power supply P1 P2 Pre-alarm output PALa PALc Switching capacity Solid state relay (SSR) Non-contact output AC/DC24 to 240V 20mA Switching capacity Contact output (1a) V AC or 200 V AC, 2 A Resetting method When the load current becomes lower than the preset current value, the alarm is reset. Resetting method Press the reset button, or turn off the control power supply. Pre-alarm module output rating Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s Pre-alarm operating characteristics Long time delay operating time, TL s (at 200%) 150s s 60s 12s Pre-alarm current Ip Inx ( ) ±10% Pre-alarm operating time Tp TL Tp= (at200%) Current (% to rated current In) RESET PALOUT LED Reset switch PALa Pre-alarm output P2 Control power supply P1 (PALc) Voltage V 200 AC Current (A) Resistive load 3 3 Inductive load 2 2 A control power supply (compatible with to 200 V AC) is necessary. For the wiring method, see the following figure. (The control power supply voltage range is 0 to 242 V AC.) The required volt-ampere is 10 VA. Vertical lead wire terminal block PALa P2 P1 PALc Indicating lamp (example) Control power supply Other d Pre-alarm LED display (stard device) When the load current exceeds the preset current value, the LED lamp on the circuit breaker front panel starts blinking. When the prealarm output is given, the lamp stops blinking turns on. d Pre-alarm current setting (IP setting) The pre-alarm current can be set to the rated current In 0.7, 0.75, 0., 0.5, 0.9, 0.95 or 1.0 with the knob on the circuit breaker front panel.

80 OFF OPEN RESET O N F OF ESET D TR IPPE R O N J 740 Low-Voltage External Other F-Type Operating Hle Operating hle of breaker mount type to be installed to circuit breaker body DAppearance D (Color: Munsell N1.5) DOutline D drawings Center of circuit breaker operating hle Table 20 Summary of dimensions Type name F-05SV2 F-05SVE2 F-05SV F-05SVE (*2) F-1SV2, F-1SVE2 F-1SV F-1SVE F-1UV, F-1UVE F-2SV F-2SVE F-2UV, V-2UVE F-1SVUL F-2SVUL F-03SVUL2 F-03SVUL F-05SVUL2 F-05SVUL F-2SUL F-4S F-4SE F-4U F-4UE F-S F-SE F-U F-UE F-4SUL F-6SUL F10SW (*3) F10SW4P (*3) K Trip button L Trip button M Trip button Center of circuit breaker hle operating hle 62 (a) Door opening position OFF Reset position position f65 Release knob T R I P P E D B 4-f12 62 B Front plate DDThe hle provides an isolating function in combination with the circuit breaker body (except F10SW above). DDIt has a safety device which prevents the circuit breaker turning on while the door is open. DDIt can be locked in the OFF position. (Up to 3 commercially available padlocks (35 mm 40 mm) can be fitted. A type which can be locked in the ON or OFF position can be manufactured. Specify the type if required.) On circuit breakers with a frame size of 0A or above, the hle can be locked in the ON or OFF position. (If it is necessary to lock the hle only in the OFF position, specify so.) DDIt is in protection class IP54 (IEC 60529). (For circuit breakers with a frame size of 0A or above, the protection class (IEC 60529) is IP3X (IP5X when dust-proof packing is provided). MCCB NF32-SV NF63-CV, NF63-SV, NF63-HV NF32-SV NF63-CV, NF63-SV, NF63-HV NF125-CV, NF125-SV NF125-CV, NF125-SV NF125-HV NF125-UV NF125-SEV, NF125-HEV, NF125-RV NF125-SGV, NF125-LGV, NF125-HGV NF160-SGV, NF160-LGV, NF160-HGV NF250-SGV, NF250-LGV, NF250-HGV NF250-CV, NF250-SV, NF250-HV NF250-SEV, NF250-HEV, NF250-RV NF250-UV NF125-SVU, NF125-HVU NF250-SVU, NF250-HVU NF50-SVFU NF-CVFU NF225-CWU NF400-CW, SW, SEW, HEW, REW NF630-CW, SW, SEW, HEW, REW NF400-UEW Packing N Thickness: 150 Trip 1.2 to 3.2 f20 button Release 3 Thickness: 1.2 to knob Auxiliary hle (Note) 50 A± A±2 Fig. 1 Fig. 2 Fig. 3 Center of circuit breaker operating hle Center of circuit breaker hle operating hle Center of circuit breaker hle Circuit breaker Center of operating hle NF00-CEW, SDW, SEW NF00-HEW, REW NF00-UEW NF400-UEW(4P) NF400-SWU/HWU NF630-SWU/HWU NF0-SEW NF1250-SEW/SDW NF1600-SEW/SDW C 7 (b) (f) f90 (b) (b) Center of operating hle Applicable model Number of poles 2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P 4P ELCB NV125-SEV, NV125-HEV 2P 3P 4P NV250-CV, NV250-SV, NV250-HV NV250-SEV, NV250-HEV 2P 3P 4P 3P 3P 2P 3P 2P 3P 3P 2P, 3P, 4P 3P 2P, 3P, 4P NV00-SEW, HEW 3P, 4P 3P 3P 2P, 3P 4P NV32-SV NV63-CV, NV63-SV, NV63-HV NV125-CV, NV125-SV, NV125-HV NV125-SVU, NV125-HVU NV250-SVU, NV250-HVU NV50-SVFU NV-CVFU NV400-CW, SW, SEW, HEW, REW NV630-CW, SW, SEW, HEW Notes *1 The dimensions for the front connection type are shown. On some models of the rear connection type plug-in type, the reference surface for mounting the circuit breaker may change. *2 For the plug-in type, a special hle is required. Consult us for details. *3 If a hle which can be locked only in the OFF position is required, specify so. *4 The circuit breaker can be tripped by operating the trip button while the door is open. *5 Do not remove the sponge packing used to secure the protection class IP51. Fit the supplied packing without fail. *6 The hle cannot be used when the circuit breaker is installed on IEC 35-mm rails. D 4-f12 7 F Decorative board Front plate Hle (c) (g) f90 Packing D 7 F (d) (h) 112 C 150 f11 G D 112 Reference drawing Dimensional Number of poles drawing Drilling plan f 2P 3P 3P 4P 3P 4P 3P 3P 2P 3P 3P 3P, 4P 3P 3P Thickness: 1.2 to 3.2 Note Auxiliary hles are provided with F10SW, F10SW4P F120UR as stard. Auxiliary hles (F-HT) are provided for F-4S ~ F-6SUL as option. DDimensional D drawings of front plate drilling Center of circuit breaker E Center of circuit breaker hle operating hle 4-f12 Circuit breaker Center of operating hle Center of circuit breaker hle (a) (b) C (b) (a) E Center of circuit breaker operating hle Center of circuit breaker Center of circuit breaker hle operating hle 4-f15 (a) (b) (b) (a) Center of circuit breaker hle E A 2 Circuit breaker F Center of operating hle Center of circuit breaker hle operating hle DDimensional D drawings of circuit breaker mounting holes Fig. 1 (e) 112 f11 b c b c c b a b b d e d e d 4-f15 A (*1) Fig. 3 d g 221 g f g h f h h g f g f g g g h g h g Fig (mm) B C D E F G J For 30 to 250 A frames For 400 to 00 A frames Dust-proof packing (optional) Type name M4 screw or f5 M6 screw or f7 M screw or f The left drawing shows the relationship between the hinges circuit breaker viewed from the load side of the circuit breaker Trip button position (*4) Remarks: 1. The hles with E in their model names are designed for emergency stop devices. Their delivery category is. 2. The stard hles are Reset Open Type which can open the doors only when they are reset to open. OFF Open type hles which can open the doors when they are in the OFF position can be manufactured to order. 3. A hle which can be operated can indicate the ON OFF positions in the same manner as the stard models even if the circuit breaker is installed horizontally can be manufactured to order. 4. F10SW higher models do not conform to the isolation function. 5. Hles which are opened closed in the OFF position can be opened also in the reset position. PFL For 0 to 1600 A frames 11 Operating hle type name F10SW~F120UR N L N L L K K L K M N L Delivery category Center of hinge breaker Left hinge Operating hle H X1 Circuit breaker L Interlock engaging part F(N) X2 H Front plate Right hinge Hinge on left side Hinge on right side H X1 H X2 Less than 10 1 or more (5H+5) 0 or more (5H+120) or more 10 or more or more 0 or more 0 or more Center of hinge circuit breaker (5H+5) or more (H+150) or more 0 or more 0 or more (4H+120) or more (4H+120) or more Remarks: 1. The hle is opened closed in the projection area of the hle does not run over the projection area of the circuit breaker (except when the auxiliary hle is provided.) 2. When the operating hle is fitted to NV, the test button cannot be pressed easily. If necessary, use a circuit breaker with TBL or TBM. When using an Alarm, use the externally resetting type (ECA-SLT RST) or automatically resetting type (ARS). DDoor D lock withst load F-05~F-2 F-4~F- F(N) 500 L(mm) 50 6 Mounting screw (a) Circuit breaker mounting screw (2 pcs.) (b) Circuit breaker hle mounting screw (2 pcs.) F-05SV2 F-05SVE2 F-1SV2 F-1SVE2 F-05SRUL2 F-03SVUL2 F-05SVUL2 Only the screws (b) are used for the following models. (a)(b) Circuit breaker mounting screw (4 pcs.)

81 Low-Voltage Circuit P.664 Magnetic Contactor Starters P D D procedure For details, please refer to Operating Hle Manual supplied with the product. q to a breaker Install the operating hle to the circuit breaker in accordance with the following procedure. procedure Circuit breaker mounting screw (2 pcs.) (a) Hle Operating hle mounting screw (2 pcs.) (b) ( procedure) q Install the circuit breaker on the panel with the two circuit breaker mounting screws through the holes (a). w Install the operating hle with the supplied two operating hle mounting screws through the holes (b). 250A frame below 2 poles 3 poles Center of operating hle center of circuit breaker 4 poles position of operating hle with respect to circuit breaker (Note 1) In the case of F-05SV2, F-1SV2, F-05SRUL2, F-05SUL2 F-1SUL2 Tighten the circuit breaker operating hle together with the supplied two operating hle mounting screws. Note *1 In the case of F-05SRUL2, the center of the operating hle is the same as the center of the circuit breaker. Circuit breaker cover screws (Remove.) Circuit breaker mounting screw (supplied with body) Spacer for installation of operating section (supplied) 400 to 1600A frames (Power supply side) (Load side) Circuit breaker cover screws (Remove.) Hle Operating section mounting screw (supplied) (In the case of F-4S to F-6SUL) The operating hle mounting screws are tapping screws without washers or spring washers. ( procedure) q Remove the circuit breaker cover screws in the same positions as the operating hle mounting holes. w Install the circuit breaker with the four circuit breaker mounting screws. e Fit the spacer(s) for installation of operating hle between the circuit breaker operating hle. (The number of the spacers varies depending on the model.) r Install the operating hle with the supplied operating hle mounting screws. Center of operating hle center of circuit breaker 3 poles 4 poles position of operating hle with respect to circuit breaker w of decorative board retaining board Drill holes in the door according to the drilling size shown on the previous page, tighten the decorative board retaining board with the supplied countersunk screws. In the case of 00A frame or below, fit the supplied packing to the position shown right. d Door locking mechanism The panel door can be opened only when the operating hle is operated to open (reset). (On F-4S to F10SW, the door lock is held in the released state even if the hle is returned to OFF.) The door can be opened when the hle is in the ON position if the release knob is operated with a tool. d Operation locking mechanism Circuit breakers with a frame size of 00A or below can be locked by setting the hle in the OFF position. (Operating hles which can lock circuit breakers in the ON or OFF position can be manufactured.) Operate the locking part, lock the hle with padlocks. Up to three padlocks can be fitted. Lockout hasps (scissors locks) can be used. If the circuit breaker trips even when the operating hle is locked in the ON position, also the operating hle indicates that it has tripped. F-2SUL or below: Only when one 35-mm padlock (weighing g or less) is used F-4S or above: Only when one 40-mm padlock (weighing g or less) is used To 00A frame or below, padlocks with dimension C of 3 mm to mm can be applied. For 0A or above, padlocks with dimension of 3 mm to 6 mm can be applied. (When using padlocks of 3 mm or less, please consult us.) d Circuit breaker installation direction (except UL 49 listed circuit breakers) We can supply circuit breakers on which the hles their ON OFF positions are in the same directions as on vertically installed circuit breakers even when they are installed horizontally. The door drilling size is identical. If you intend to install an operating hle on a horizontally installed circuit breaker, specify Y (horizontal installation with power supply on the left) or Z (horizontal installation with power supply on the right) at the end of the model name. (Ex.: F-4S Y) d Sealing of release knob The use of an optional part, Release Protection F-RCS, can prevent the panel door being opened by operating the release knob. (00A frame or below) Power supply When F-RCS is not used Hle Decorative board Countersunk screw Lord Release knob Power supply Lord Front plate (door) Interlock lever Interlock engaging part Retaining board Packing (for 00A frame or below) Lord F-RCS Power supply When F-RCS is used (sealed state) d Operation Lock Devices (1) Padlock (2) Lockout Devices (Scissors Lock) d How to order For 00A frame or below, specify the following specification symbols together with the model name. Operation lock: LF Lock in OFF position Operation lock: LN Lock in ON or OFF position Door opening: DR Reset to open Operation lock: DF Open in OFF position direction: Blank Power supply upward direction: Y Power supply on left Operation lock: Z Power supply on right For a stard product with a frame size of 0A or above, specify the model name. When it is required to enable the operation lock only in the OFF position, specify the model name only lock in OFF position. If you intend to seal the release knob, place an order for the release protection. (Lot: 10 pcs.) d Interpretation of model name (1) For 00A frame or below F 1 SV UL E 1) 2) 3) 4) 5) 1) F: 2) 1: 3) SV: 4) UL: 5) E: 6) 2: C B A (2) For 0A frame or above F 10 SW 4P 1) 2) 3) 4) 1) F: Operating hle type name 2) 4: Circuit breaker A frame (10 or 120) 3) SW: Series name 4) 4P: Number of poles (4P) * Not indicated for 3P 2 6) Padlock Use commercially available padlocks. Applicable A (Nominal size) B model All models Dimension C: Maximum mm. Operating hle type name Circuit breaker group (0.5, 1, 2, 4, 6 or ) Classification of circuit breaker (S, SV, H, U, UV, SR or SG) Blank General product UL UL 49 listed product Blank Stard E For emergency stop Blank 3P or 4P 2 2P or 23 C (mm) Other

82 OFF TRI ON E E OF F ESET R ON 742 Low-Voltage External Other V-Type Operating Hle DAppearance D (Color: Munsell N1.5) DOutline D drawings M Trip button Front plate 12 Thickness: A to C±2 N Trip button Fig. 1 Center of operating hle Center of circuit breaker hle operating hle 40 (a) ø9 40 ø40 B 90 K Trip button L Trip button RESET PPED M Trip button 90 N Trip button Center of circuit breaker hle operating hle Center of ø9 circuit breaker Center of operating hle 54 (b) Operating hle of door mount type consisting of operating section to be mounted on circuit breaker body operating hle on panel door The hle provides an isolation function in combination with the circuit breaker body. Conforming to the safety regulations of EN Stard (EN ) Protection class (IEC 60529) IP65 as stard The hle can be locked only in the OFF position with up to three commercially available padlocks (35 mm or 40 mm). The panel door can be opened in the OFF position. In the ON trip positions, the panel door is locked cannot be opened. However, the door can be opened even in the ON trip positions by operating the release part with a tool. Front plate Thickness: 1.2 to 3.2 Thickness: A B to 3.2 A B 54 C (stationary type) ±2 62 C (stationary type) ±2 D (adjustable type) ±2 D (adjustable type) ±2 Fig. 2 Fig. 3 DDimensional D drawings for front plate drilling ø54 E Dimensional drawings of circuit breaker mounting holes Center of circuit breaker hle Circuit breaker Center of circuit breaker operating hle F (d) J Center of circuit breaker G Center of circuit breaker operating hle F (e) Center of circuit breaker circuit breaker hle G J Center of circuit breaker hle Center of circuit breaker operating hle Table 21 Summary of dimension F F/2 (f) F Center of circuit breaker J G 54 Center of circuit breaker Center of operating hle Center of circuit breaker G Center of operating hle Center of circuit breaker circuit breaker hle T RIPPED Center of circuit breaker hle operating hle 4-ø10 Center of circuit breaker (c) Center of circuit breaker hle E G Front plate Note Auxiliary hles (F-HT) are provided for V-4S ~ V-6SUL as option. 104 ø63 Center of circuit breaker Center of circuit breaker hle G CL 4 poles 3 poles CL F Center of F/2 F operating Center of J hle F F J circuit breaker operating hle (g) (h) (j) CL Dimensional drawing J Circuit breaker Center of hinge breaker H Left hinge For 30 to 250 A frames For 400 to 00 A frames Circuit breaker X F(N) H 0 or more Front plate Right hinge X 5H+ or more H+150 or more * The above figure shows the relationship viewed from the load side. F(N) 30 to 00A frames 200 X H Relationship between hinges circuit breaker viewed from load side of circuit breaker DDoor D lock withst load Type name Applicable model Reference drawing (mm) Stationary Adjustable Stationary Drilling type type(*2) Adjustable type MCCB ELCB A B E F G J type Number Number plan D D C of poles of poles (min) (max) V-05SV2 NF32-SV 2P d 12.5 N V-05SVE2 NF63-CV, NF63-SV, NF63-HV NV32-SV V-05SV NF32-SV 3P NV63-CV, NV63-SV, NV63-HV 2P, 3P e L V-05SVE NF63-CV, NF63-SV, NF63-HV 4P V-1SV2, V-1SVE2 NF125-CV, NF125-SV 2P d N 3P NV125-CV, NV125-SV 3P e NF125-CV, NF125-SV V-1SV 4P NV125-HV 4P f V-1SVE (*1) 2P, 3P e Adjusting unit NF125-HV 30 M4 L 4P Fig. f V-AD3S is b screw V-1UV 2 mounted on 2P, 3P g NF125-UV or f5 V-1UVE stationary type. 4P h NF125-SEV, NF125-HEV, NF125-SGV NF125-LGV, NF125-HGV, NF125-RGV 2P, 3P NV125-SEV, NV125-HEV 3P e V-2SV NF160-SGV, NF160-LGV, NF160-HGV NV250-CV, NV250-SV, NV250-HV 126 V-2SVE NF250-CV, NF250-SV, NF250-HV NV250-SEV, NV250-HEV NF250-SGV, NF250-LGV, NF250-HGV K 4P 4P f NF250-SEV, NF250-HEV, NF250-RGV V-2UV 2P, 3P g NF250-UV V-2UVE 4P h V-03SVUL2 2P 2P Fig. d 9 M NF50-SVFU NV50-SVFU a V-03SVUL 3P 3P 1 e 1 N V-05SVUL2 (*1) 2P Fig. d 12.5 M4 N NF-CVFU b V-05SVUL Adjusting unit 3P NV-CVFU 3P 2 e screw L V-1SVUL V-AD3S is NF125-SVU, NF125-HVU 3P NV125-SVU, NV125-HVU 3P g or f5 L mounted on Fig V-2SVUL NF250-SVU, NF250-HVU 3P NV250-SVU, NV250-HVU 3P b K stationary type. 2 e 41 V-2SUL NF225-CWU 3P 3P V-4S NF400-CW/SW/SEW/HEW/REW V-4SE NF630-CW/SW/SEW/HEW/REW 2P, 3P, 4P NV400-CW/SW/SEW/HEW/REW 3P, 4P j NV630-CW/SW/SEW/HEW (*1) 44 V-4U Adjusting unit NF400-UEW 3P h V-4UE M6 Fig. V-S V-AD3L is c 76 screw 3 mounted on NF00-CEW/SDW/SEW/HEW/REW 2P, 3P, 4P NV00-SEW/HEW 3P 243 V-SE or f7 stationary type. j V-4SUL NF400-SWU/HWU 3P 3P V-6SUL NF630-SWU/HWU 3P 243 Notes *1 For the adjustable type, purchase the optional adjusting unit V-AD3S or V-AD3L. *2 The dimensions of the adjustable type models provided with the adjusting unit V-AD3S or V-AD3L are shown. *3 When using the operating hle for a plug-in type model with a frame size of 250A or below, specify so. *4 The dimensions on the front connection type are shown. For the rear connection plug-in types, separately consult us. *5 The circuit breaker can be tripped by operating the trip button while the door is open. (The trip button position varies depending on the model.) *6 The hle cannot be used when the circuit breaker is installed on IEC 35-mm rails. Trip button position (*5) Remarks: 1. The products whose model names contain E are designed for emergency stop. The delivery category is d. That of V-05SVE is d. 2. When the operating hle is fitted to NV, the test button cannot be pressed easily. If necessary, use a circuit breaker with TBL or TBM. When using an Alarm, use the externally resetting type (ECA-SLT) or automatically resetting type (ARS).

83 Low-Voltage Circuit Magnetic Contactor Starters P.664 For details, please refer to Operating Hle Manual supplied with the product. q to a breaker Install the operating hle to the circuit breaker in accordance with the following procedure. 400 to 00A frames ( procedure) q Operating hle for 3- or circuit breaker Set the rotary plate of the operating section to the OFF (symbol O) position, fit the plate to the circuit breaker with the supplied operating section mounting screws nuts. Install the circuit breaker to the panel with the circuit breaker mounting screws (2 pcs.). w Operating hle for 2-pole circuit breaker Install the operating section together with the circuit breaker to the panel with the supplied operating section mounting screws (2 pcs.) q Remove the circuit breaker cover screws (4 pcs.) in the same positions as the operating hle mounting holes. w Install the circuit breaker with the circuit breaker mounting screws (4 pcs.). e Fit the supplied operating section mounting spacers (4 pcs.) between the circuit breaker operating hle. r Set the rotary plate to the OFF (symbol O) position, install the operating section to the circuit breaker with the supplied operating section mounting screws. Circuit breaker cover screws (Remove.) Nut M4 (2 pcs.): Except for 2-pole circuit breaker Circuit breaker mounting screw (M6, 4 pcs.) (supplied with body) Operating section (Power supply side) Spacer for installation of operating section (supplied) Rotary plate Projection (Load side) Projection Circuit breaker Circuit breaker cover screws (Remove.) Rotary plate pin Operating section Circuit breaker mounting screw (2 pcs.) Operating section Joints Shaft Warning mark Front plate (mm) Min Max P Cutting allowance V-05SV V-05SVUL Shaft V-2SGUL X V-4S Cutting allowance (Cutting allowance)(p max)(panel size) X = 300 mm - P Shaft Release knob d Adjusting unit The height from the circuit breaker mounting surface to the panel door can be adjusted by fitting the optional adjusting unit V-AD3S or V-AD3L. Cut the shaft of the adjusting unit according to the height. X 109 Cutting allowance Note The unit is applicable to operating hles for emergency stop (E). d Padlocks The user must prepare padlocks. The dimensions of the padlocks are the same as those shown on page 752. d How to order Specify the model name of the operating hle. For adjustable type, place an order for the adjustment unit. (One lot includes 1 pc.) 250A frame or below: V-AD3S 400 to 00A frames: V-AD3L d Interpretation of model name (1) For 00A frame or below V 1 S UL E 1) 2) 3) 4) 5) 1) 2) 3) 4) 5) 6) V: 1: S: UL: E: 2: 2 6) Operating hle type name Circuit breaker group (0.5, 1, 2, 4, 6 or ) Classification of circuit breaker (S, SV, H, U, UV) Blank General product UL UL 49 listed product Blank Stard E For emergency stop Blank 3P or 4P 2 2P Other Padlock V-4SUL V-6SUL Locking hole V-S Calculation Type name Min Max Thickness: 1.2 to 3.2 Front plate V-2SV V-2SVUL V-2SUL Operating section Joint clamp screw Make adjustments with the adjusting unit as stated below. qexternal dimension drawing wcalculation of shaft cutting allowance V-1SV V-1SVUL V-1SUL d Operation locking mechanism q Operating hle section Operation lock can be set only in the OFF Position. Up to three commercially available padlocks (A = 35 or 40 mm) can be fitted. Lockout hasps (scissors locks) can be used. When the operating hle section is locked with padlocks, also the door is locked. w Operating section The operating section can be locked so that the circuit breaker will not be turned on carelessly when the inside of the panel is inspected with the panel door open. Fit a padlock through the hole in the operating section of the operating hle. Note The adjusting unit is not applicable to 2-pole external type circuit breakers. If it is used on a 2-pole external type circuit breaker, the positions may not be correctly displayed. d Door locking mechanism The operating hle is provided with an interlock mechanism to prevent the door opening in the ON TRIP positions. In the OFF position, the door can be opened. However, the door can be opened in the ON or TRIP position by pressing the release knob in the arrow direction with a tool (3 mm wide 1. mm thick). Operating section mounting screw (supplied) (4 pcs.) w of operating hle section Drill a hole in the door according Operating hle section mounting screw to the dimensional drawing for (250A frame or below: 2 pcs. 400A frame or above: 4 pcs.) front plate drilling given on the Operating previous page, install the hle section operating hle section in accordance with the following Washer (2 pcs.) procedure. Tighten the operating hle section from the back of the front plate. Temporarily tighten the screws to center the section in the hole. Hle Front plate Set the hle of the operating hle section to the OFF state, tighten the front plate, make sure that the hle can be smoothly turned to the ON OFF positions. Turn the hle to the right left in the OFF state, make sure that OFF is displayed. If OFF is not displayed, move the operating hle section up down to the right left for adjustment. (Take care that the operating hle section is in parallel with the circuit breaker.) Then, open the front plate, finally tighten the screws. Rotary plate Rotary plate pin Operating sectiuon mounting screw (2 pcs.) 10 procedure 250A frame below ( procedure) 743 D D procedure P.50

84 744 Low-Voltage External Other Terminal Covers The terminal covers are used to avoid exposure of live parts. Many kinds of terminal covers, including large terminal covers (TC-L), small terminal covers (TC-S), transparent terminal covers (TTC), rear terminal covers (BTC) plug-in terminal covers (PTC), for various models applications are available, they are helpful. (The terminal covers cannot be fitted to electrically operated circuit breakers of spring charged type (2) motor-drive type (2). The stard terminal covers can be used for the spring charged type (1). For the motor-drive type, special terminal covers can be manufactured. Consult us for details.) d Quick terminal covers These covers are very convenient because they can be fitted only by inserting them into the mounting holes in the circuit breaker body. To remove the terminal cover, shift the projections of the terminal cover with the tip of a slotted screwdriver or finger, draw it out. DTable D of variable dimensions Table 22 Large terminal covers (TC-L) Number Type name of poles of circuit breaker TCL-03CS2W White 2 Color Applicable model (mm) Contents Cover MCCB ELCB A B C Number mounting Sealing of covers screw plate (*1) TCL-03CS3W White 3 NF30-CS TCL-05SV2 (*2)(*) White 2 NF32-SV NF63-CV/SV/HV TCL-05SV2L(*2)(*9) White 2 NF32-SV NF63-CV/SV/HV NF32-SV TCL-05SV3 White 3 NV32-SV, NV63-HV NF63-CV/SV/HV (*3)(*) White 2, 3 NV63-CV/SV TCL-05SV3L White 3 NF32-SV, NF63-CV/SV/HV NV32-SV, NV63-HV (*3)(*9) White 2, 3 NV63-CV/SV TCL-05SV4 (*3) White 4 NF63-SV/HV TCL-1SV2 (*2) White 2 NF125-CV/SV TCL-1SV3 (*3) White 3 NF125-CV/SV NV125-CV/SV/HV White 2, 3 NF125-HV/UV TCL-1SV4 (*3) White 4 NF125-SV/HV/UV NV125-SV/HV TCL-2SV3 White 2, 3 (*3)(*10) TCL-2SV3L White 2, 3 (*3)(*11) TCL-2SV4 NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-SGV/LGV/HGV/RGV NF250-CV/SV/HV/UV, NF250-SEV/HEV NF125-SEV/HEV White 3 (*6) NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-SGV/LGV/HGV/RGV NF250-CV/SV/HV/UV, NF250-SEV/HEV NF125-SEV/HEV (*3)(*5) White 4 NV250-CV/SV/HV NV250-SEV/HEV NV125-SEV/HEV NV250-CV/SV/HV NV250-SEV/HEV NV125-SEV/HEV NF250-SV/HV/UV NV250-SV/HV NF250-SEV/HEV NV250-SEV/HEV NF125-SEV/HEV NV125-SEV/HEV NF225-SWM (*6) NV400-CW/SW/SEW White 2, 3 NF400-CW/SW/SEW NF630-CW/SW/SEW NV630-CW/SW/SEW TCL-4SW3 (*3) NF400-SEP with MDU (*7) 2 White 3 NF400-UEW (*4) / NF400-SW/SEW/HEW NV400-SEW/HEW TCL-4SW4 (*3) White 4 NF630-SW/SEW NV630-SEW NF400-SEP with MDU (*7) White 2, 3 NF00-CEW/SDW/SEW/HEW/REW NV00-SEW/HEW TCL-SW3 (*3) NF600-SEP with MDU/HEP with MDU (*7) White 3 NF00-SEP with MDU/HEP with MDU (*7) TCL-UW3 Transparent 3 NF00-UEW (*4) / NF00-SEW/HEW TCL-SW4 (*3) White 4 NF600-SEP with MDU/HEP with MDU (*7) NF00-SEP with MDU/HEP with MDU (*7) A ON B TC-L TC-S TTC Appearance Quick type The cover can be sealed with the sealing plate. TCL-UW4 Transparent 4 NF400-UEW, NF00-UEW (*4) / TCL-10SW3 Transparent 3 NF0-SEW NF1250-SEW/SDW TCL-10SW4 Transparent 4 NF0-SEW NF1250-SEW/SDW Screw type TCL-03SVU2 (*3) White 2 NF50-SVFU NV50-SVFU Quick type TCL-03SVU3 (*3) White 3 NF50-SVFU NV50-SVFU (Remove the existing cover from the body, fit the terminal cover.) TCL-05SVU2 (*2)(*) White 2 NF-CVFU TCL-05SU2L (*2)(*9) White 2 NF-CVFU TCL-05SVU3 (*3)(*) White 3 NF-CVFU NV-CVFU Screw type TCL-05SVU3L (*3)(*9) White 3 NF-CVFU NV-CVFU C Remarks Use in combination with insulating barrier. TCL-1SVU3 (*3) White 2, 3 NF125-SVU Screw type NF125-HVU NV125-SVU/HVU (Remove the existing cover from the body, fit the terminal cover.) TCL-2SVU3 (*3)(*10) White 3 NF250-SVU/HVU NV250-SVU/HVU Screw type (Remove the existing cover from the body, fit the terminal cover.) TCL-2SVU3L (*3)(*11) White 3 NF250-SVU/HVU NV250-SVU/HVU Screw type (Remove the existing cover from the body, fit the terminal cover.) TCL-2SWU3 (*10) White 3 NF225-CWU Quick type (Remove the existing cover from the body, fit the terminal cover.) TCL-2SWU3L (*3)(*11) White 3 NF225-CWU Quick type (Remove the existing cover from the body, fit the terminal cover.) TCL-4SWU White 3 NF400-SWU/HWU Quick type TCL-6SWU Transparent 3 NF630-SWU/HWU Screw type Use in combination with insulating barrier. Notes *1 For 2-pole NV, use TC-L for circuit breaker. *2 For a circuit breaker with F or V type operating hle, specify the model name with F at the end. (F or V type operating hle dedicated models, screws are used for fixing.) *3 The stard models can be used in combination with F V Type Operating Hles. *4 The dimension C is the size on the power supply side load side. *5 When a crimp terminal applicable to wires with a size of to mm 2 (Model 2CR-150 or CB150-S) is used, TC-L cannot be fitted. Insulate the terminal from TC-S with insulating tube or taping. *6 In the case of installation on the body, specify the model name with-mdu at the end. *7 It cannot be installed in the case of installation on the body. * Applicable to circuit breakers with rating of 75A or less (max. wire size 25 mm 2 ) *9 Applicable to circuit breakers with rating of 125A or less (max. wire size 60 mm 2 ) *10 Applicable to circuit breakers with rating of 200A or less (max. wire size mm 2 ) *11 Applicable to circuit breakers with rating of 250A or less (max. wire size 150 mm 2 ) (Applicable to UL wire 300MCM) Remarks: 1. The wire sizes shown in the above notes *10 to *13 are those of the 600-V vinyl insulated wires. 2. Insulate the exposed live parts of crimp terminals with insulating tape or the like. 3. When protection from the power supply load sides is necessary, separately consult us.

85 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Table 23 Small terminal covers (TC-S) Type name Color Number of poles of circuit breaker Applicable model (mm) Contents Number Cover Sealing MCCB ELCB A B C of covers mounting plate screw TCS-03CS2W White NF30-CS TCS-03CS3W White TCS-05SV2 (*1) White 2 NF32-SV, NF63-CV/SV/HV TCS-05SV3 White 3 NF32-SV, NF63-CV/SV/HV NV32-SV, NV63-HV (*2) White 2, 3 NV63-CV/SV TCS-1SV2 (*2) White 2 NF125-CV/SV TCS-1SV3 (*3) TCS-2SV3 White 3 NF125-CV/SV NV125-CV/SV/HV White 2, 3 NF125-HV/UV White 2, 3 (*2) NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-SGV/LGV/HGV/RGV NF250-CV/SV/HV/UV, NF250-SEV/HEV NF125-SEV/HEV NV250-CV/SV/HV NV250-SEV/HEV NV125-SEV/HEV Notes *1 For a circuit breaker with F type operating hle, specify the model name with F at the end. (F type operating hle dedicated models, screws are used for fixing.) *2 The stard models can be used in combination with F V Type Operating Hles Appearance Quick type The cover can be sealed with the sealing plate. Remarks Remarks: 1. Small terminal covers for circuit breakers are available. 2. Insulate the exposed live parts of crimp terminals with insulating tape or the like. Table 24 Transparent terminal covers (TTC) Number Type name of poles of circuit breaker TTC-03CS2 2 Applicable model (mm) Contents Number Cover MCCB ELCB A B C of covers mounting Sealing screw plate NF30-CS TTC-03CS TTC-05SV2 (*1) 2 NF32-SV NF63-CV/SV/HV TTC-05SV3 3 NF32-SV NF63-CV/SV/HV NV32-SV, NV63-HV (*2) 2, 3 NV63-CV/SV TTC-1SV2 (*1) 2 NF125-CV/SV TTC-1SV3 (*2) TTC-2SV3 (*2)(*3)(*5) TTC-4SW3 3 NF125-CV/SV NV125-CV/SV/HV 2, 3 NF125-HV/UV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NV250-CV/SV/HV 2, 3 NF250-SGV/LGV/HGV/RGV NV250-SEV/HEV NF250-CV/SV/HV/UV, NF250-SEV/HEV NV125-SEV/HEV NF125-SEV/HEV 2, 3 TTC-4SW4 4 TTC-SW3 3 NF400-CW/SW/SEW NF400-HEW/REW NF630-CW/SW/SEW NF630-HEW/REW NV630-HEW NV400-CW/SW/SEW NV400-HEW/REW NV630-CW/SW/SEW 3 NF400-SEP with MDU/HEP with MDU (*4) NF400-SW/SEW/HEW NV400-SEW/HEW NF630-SW/SEW/HEW NV630-SEW NF400-SEP with MDU/HEP with MDU (*4) 2, 3 TTC-SW4 4 3 NF00-CEW/SDW/SEW NV00-SEW/HEW NF00-HEW/REW NF600-SEP with MDU/HEP with MDU (*4) NF00-SEP with MDU/HEP with MDU (*4) NF00-SEW/HEW NF600-SEP with MDU/HEP with MDU (*4) NF00-SEP with MDU/HEP with MDU (*4) Notes *1 For a circuit breaker with F type operating hle, specify the model name with F at the end. (F type operating hle dedicated models, screws are used for fixing.) *2 The stard models can be used in combination with F V Type Operating Hles Transparent Transparent Appearance Quick type The cover can be sealed with the sealing plate. Screw type *3 When a crimp terminal applicable to wires with a size of to mm 2 (Model 2CR-150 or CB150-S) is used, TTC cannot be fitted. Use TCL-2SV3L. Or insulate the terminal from TC-S with insulating tube or taping. *4 In the case of installation on the body, specify the model name with MDU at the end. *5 Applicable to circuit breakers with rating of 200A or less (max. wire size mm 2 ) Remarks Use in combination with insulating barrier. Other

86 746 Low-Voltage External Other <BTC> Fig. 1 Fig. 2 A ON B Table 25 Rear terminal cover (BTC) Type name Color C Number of poles of circuit breaker BTC-03CS2W White 2 NF30-CS Table 26 Plug-in terminal covers (PTC) A ON B C <PTC> Applicable model (mm) Contents Number Cover Sealing MCCB ELCB A B C of covers mounting plate screw BTC-03CS3W White BTC-05SV2 White 2 NF32-SV NF63-CV/SV/HV (*1) NF32-SV White 3 NV32-SV, NV63-HV BTC-05SV3 NF63-CV/SV/HV White 2, 3 NV63-CV/SV BTC-1SV2 White 2 NF125-CV/SV BTC-1SV3 White 3 NF125-CV/SV NV125-CV/SV/HV White 2, 3 NF125-HV/UV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NV250-CV/SV/HV BTC-2SV3 White 2, 3 NF250-SGV/LGV/HGV/RGV NV250-SEV/HEV NF250-CV/SV/HV/UV, NF250-SEV/HEV NV125-SEV/HEV NF125-SEV/HEV White 2, 3 NF400-CW/SW/SEW NV400-CW/SW/SEW NF630-CW/SW/SEW NV630-CW/SW/SEW (*2) BTC-4SW3 NF400-SEP with MDU (*5) (*5) 2 White / NF400-UEW (*4) (*2) BTC-4SW4 (*3) Transparent 4 NF400-SW/SEW/HEW NV400-SEW/HEW NF630-SW/SEW/HEW NV630-SEW NF400-SEP with MDU/HEP with MDU (*5) (*2) Transparent 2, 3 NF00-CEW/SDW/SEW/HEW/REW NV00-SEW/HEW NF600-SEP with MDU/HEP with MDU (*5) (*2) BTC-SW3 (*3) NF00-SEP with MDU/HEP with MDU (*5) Transparent 3 146/ NF00-UEW (*4) (*2) NF00-SEW/HEW NF600-SEP with MDU/HEP with MDU (*5) (*5) (*2) BTC-SW4 (*3) Transparent 4 NF00-SEP with MDU/HEP with MDU (*5) NF400-UEW, NF00-UEW (*4) (*2) 146/ Notes *1 For 2-pole ELCB, use BTC for circuit breaker. *2 Dimension B in Fig. 2 *3 The covers can be used for plug-in type circuit breakers. Other models are designed only for rear connection type. *4 The dimension C is the size on the power supply side load side. *5 In the case of installation on the body, it can be fitted only on the power supply side. Number Type name of poles of circuit MCCB ELCB A B C D breaker NF32-SV PTC-05SV2 White 2 NF63-CV/SV/HV NF32-SV White 3 NV32-SV, NV63-HV NF63-CV/SV/HV PTC-05SV3 White 2, 3 NV63-CV/SV Color A B Quick type The cover can be sealed with the sealing plate. Appearance Screw type Remarks: 1. PTC-4SW3 can be used as the back terminal covers for NF400-HEW/REW, NF630-HEW/REW, NV400-HEW/REW NV630-HEW. 2. For terminal covers for circuit breakers not listed above, consult us. Applicable model (mm) Contents Number Cover of covers mounting Sealing screw plate PTC-1SV2 White 2 NF125-CV/SV White 3 NF125-CV/SV NV125-CV/SV/HV PTC-1SV3 White 2, 3 NF125-HV/UV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NV250-CV/SV/HV PTC-2SV3 White 2, 3 NF250-SGV/LGV/HGV/RGV NV250-SEV/HEV NF250-CV/SV/HV/UV, NF250-SEV/HEV NV125-SEV/HEV NF125-SEV/HEV NF400-CW/SW/SEW NV400-CW/SW/SEW PTC-4SW3 (*2) Transparent 2, 3 NF630-CW/SW/SEW NV630-CW/SW/SEW NF400-HEW/REW (*1) NV400-HEW/REW (*1) NF630-HEW/REW (*1) NV630-HEW (*1) Notes *1 The covers can be used as back terminal covers. *2 See Fig. 2 of BTC Appearance Screw type Same as screw type of BTC D C Remarks Cover for connection block in the case of simple rear connection Cover for stud connection block on back in the case of rear connection type Remarks Cover for stud connection block in the case of plug-in type

87 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Table 27 List of terminal covers applicable to F V Type Operating Hles Type name Applicable operating Large terminal covers Small terminal covers Transparent terminal hles (TC-L) (TC-S) covers (TTC) TCL-05SV2F (*2)(*3) TCS-05SV2F TCL-05SV2LF (*2)(*4) (*2) TTC-05SV2F (*2) F-05SV2, V-05SV2 TCL-05SV3 (*3) TCS-05SV3 TTC-05SV3 TCL-05SV3L (*4) F-05SV, V-05SV TCL-05SV4 TCL-1SV2F (*2) TCS-1SV2F (*2) TTC-1SV2F (*2) F-1SV2, V-1SV2 TCL-1SV3 TCS-1SV3 TTC-1SV3 F-1SV, V-1SV TCL-1SV4 TCL-2SV3 (*5) TCS-2SV3 TTC-2SV3 TCL-2SV3L (*6) F-2SV, V-2SV TCL-2SV4 TCL-4SW3 TTC-4SW3 TCL-4SP3W F-4S TCL-4SW4 TTC-4SW4 V-4S TCL-SW3 TCL-SW4 TTC-SW3 TTC-SW4 F-S V-S Notes *1 For 2-pole NV, use a terminal cover for circuit breaker. *2 Only for F V Type Operating Hles (screw type) *3 Applicable to circuit breakers with rating of 75A or less (max. wire size 25 mm 2 ) *4 Applicable to circuit breakers with rating of 125A or less (max. wire size 60 mm 2 ) *5 Applicable to circuit breakers with rating of 200A or less (max. wire size mm 2 ) *6 Applicable to circuit breakers with rating of 250A or less (max. wire size 150 mm 2 ) Number of poles of circuit breaker 2 3 2, , 3 4 2, 3 4 2, 3 4 2, 3 4 NF32-SV, NF63-CV/SV/HV NF32-SV, NF63-CV/SV/HV NF32-SV, NF63-CV/SV/HV NF125-CV/SV NF125-CV/SV NF125-HV/UV NF125-CV/SV/HV/UV NF250-CV/SV/HV/UV, NF250-SEV/HEV NF125-SEV/HEV NF250-CV/SV/HV/UV, NF250-SEV/HEV NF125-SEV/HEV NF400-CW/SW/SEW/HEW/REW NF630-CW/SW/SEW/HEW/REW NF400-SW/SEW/HEW NF630-SW/SEW/HEW NF00-CEW/SDW/SEW/HEW/REW NF00-SEW/HEW MCCB Applicable model ELCB (*1) NV32-SV, NV63-HV NV63-CV/SV NV125-CV/SV/HV NV125-CV/SV/HV NV250-CV/SV/HV, NV250-SEV/HEV NV125-SEV/HEV NV250-CV/SV/HV, NV250-SEV/HEV NV125-SEV/HEV NV400-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW NV400-SEW/HEW NV630-SEW NV00-SEW/HEW Remark: 1. The terminal covers for can be normally combined with F Type Operating Hles. Insulating Barriers The insulating barrier enhances the insulation between the phases of circuit breaker terminals. It also prevents accidents due to conductive foreign matter dust, secondary accidents when isolating a fault current. DThe D insulating barrier is available for the models listed in the table below. Table 2 MCCB NF32-SV, NF63-CV NF125-CV, NF-CVFU NF63-SV/HV NF125-SV/HV NF125-SEV/HEV, NF125-ZEV NF250-CV/SV/HV/SEV/HEV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-SGV/LGV/HGV/RGV NF250-SEV/HEV/ZEV with MDU NF125-SVU NF125-HVU NF250-SVU NF250-HVU NF225-CWU NF400-CW/SW/SEW/HEW/REW/UEW NF630-CW/SW/SEW/HEW/REW NF400-UEW(4P) NF00-CEW/SEW/HEW/REW/SDW NF00-UEW NF400-SWU/HWU NF630-SWU/HWU NF0-SEW, NF1250-SEW/SDW Applicable model NV32-SV, NV63-CV NV125-CV, NV-CVFU NV63-SV/HV NV125-SV/HV NV125-SEV/HEV NV250-CV/SV/HV/SEV/HEV NV250-SEV/HEV with MDU ELCB NV125-SVU NV125-HVU NV250-SVU NV250-HVU NV-SWU NV400-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW NV00-SEW/HEW ( denotes optional) Connecting method Front Rear Flush plate Plug-in Stard attachment Stard attachment Stard attachment Stard attachment Stard attachment Stard attachment Stard attachment Stard attachment Stard attachment Stard attachment Stard attachment Other NF1600-SEW/SDW Stard attachment Always mount the insulating barrier when it comes with the circuit breaker.

88 74 Low-Voltage External DInsulating D Barrier-Front (BA-F) Table 29 Summary of dimensions Type name BAF-05SV BAF-2SV NF32-SV NF63-CV NF125-CV NF63-SV/HV Applicable model (mm) Quantity per breaker MCCB ELCB A B 2P 3P 4P NV32-SV NV63-CV NV125-CV NF125-SV/HV/UV NF125-SEV/HEV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-CV/SV/HV/UV/SEV/HEV NF250-SGV/LGV/HGV/RGV NF250-SEV/HEV/ZEV with MDU NV63-SV/HV NV125-SV/HV NV125-SEV/HEV NV250-CV/SV/HV/SEV/HEV NV250-SEV/HEV with MDU 1 (*2) NF-CVFU NV-CVFU BAF-05SVU NF125-SVU NF125-HVU NV125-SVU NV125-HVU BAF-2SVU NF250-SVU NV250-SVU NF250-HVU NV250-HVU BAF-2SWU NF225-CWU NF400-CW/SW/SEW/HEW/REW NF630-CW/SW/SEW/HEW/REW NV400-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW BAF-4SW BAF-4UW (*1) NF400-UEW(3P) / BAF-SW NF00-CEW/SEW/SDW/HEW/REW NV00-SEW/HEW BAF-10SW BAF-4SWU NF400-UEW(4P) NF00-UEW, NF0-SEW NF1250-SEW/SDW NF400-SWU/HWU NF630-SWU/HWU(less than 600A) Reference diagram A B BAF-6SWU NF630-SWU/HWU(630A) BAF-16SW NF1600-SEW/SDW Notes *1 The barriers BAF-4UW for the power supply load sides vary in the dimension B. *2 Not supplied with ELCB. Other DInsulating D Barrier-Rear (BA-B) Table 30 Summary of dimensions Type name BAB-4SW BAB-SW MCCB NF400-CW/SW/SEW/HEW/REW NF400-UEW(3P) NF630-CW/SW/SEW/HEW/REW NF00-CEW/SEW/SDW/HEW/REW NF400-UEW(4P) NF00-UEW Applicable model (mm) Quantity per breaker ELCB A B 2P 3P 4P NV400-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW NV00-SEW/HEW Drilling size for use of BA-B (in the case of circuit breaker) NF400-CW, NF400-SW, NF400-SEW, NF400-HEW, NF400-REW, NF400-UEW NV400-CW, NV400-SW, NV400-SEW, NV400-HEW, NV400-REW NF630-CW, NF630-SW, NF630-SEW, NF630-HEW, NF630-REW NV630-CW, NV630-SW, NV630-SEW, NV630-HEW Reference diagram NF00-CEW, NF00-SEW, NF00-HEW, NF00-REW, NF00-UEW NV00-SEW, NV00-HEW Power supply side Note The dimensions in brackets are those for NF400-UEW. Note The dimensions in brackets are those for NF00-UEW. 6-f [234] 225[265] 4 screws M6 or f screws M4 Make these eight threaded holes 7 in addition to the stard holes. Load side The drilling size drawings show the dimensions viewed from the rear side f [290] 4 screws M6 or f7 screws M4 Make these eight threaded holes in addition to the stard holes. B A Mounting panel

89 Low-Voltage Circuit P.664 Magnetic Contactor Starters P DInsulating D Barrier-Plug-in (BA-P) Table 31 Summary of dimensions Type name BAP-2SV BAP-4SW BAP-SW MCCB NF125-SEV/HEV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-CV/SV/HV NF250-SGV/LGV/HGV/RGV NF250-SEV/HEV NF400-CW/SW NF400-SEW/HEW/REW/UEW NF630-CW/SW NF630-SEW/HEW/REW NF00-CEW/SEW NF00-HEW/REW NF0-SEW NF1250-SEW Applicable model (mm) Quantity per breaker ELCB A B 2P 3P 4P NV125-SEV/HEV NV250-CV/SV/HV/SEV/HEV NV400-CW/SW NV400-SEW/HEW/REW NV630-CW/SW NV630-SEW/HEW NV00-SEW/HEW DEarth D fault preventing barriers (BA-G) Table 32 Summary of dimensions Applicable model (mm) Quantity per breaker Type name MCCB ELCB A B 3P NF32-SV NV32-SV BAG-05SV NF63-CV/SV/HV NV63-CV/SV/HV BAG-1SV3 NF125-CV/SV/HV NV125-CV/SV/HV BAG-2SV3 BAG-4SW3 NF125-SEV/HEV NF250-CV/SV/HV/SEV/HEV NF250-SEV/HEV/ZEV with MDU NF400-CW/SW/SEW/HEW/REW NF630-CW/SW/SEW/HEW/REW NV125-SEV/HEV NV250-CV/SV/HV/SEV/HEV NV250-SEV/HEV with MDU NV400-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW BAG-4UW3 NF400-UEW BAG-SW3 NF00-CEW/SEW/SDW/HEW/REW NV00-SEW/HEW BAG-UW3 NF00-UEW BAG-10SW3 NF0-SEW NF1250-SEW/SDW BAG-16SW3 NF1600-SEW/SDW Also the earth fault preventing barriers for 2- circuit breakers are available. 1 Reference diagram B B A A Reference diagram B A Earth fault preventing barrier (3 poles) Other

90 750 Low-Voltage External Other Hle Lock Devices, Lock Covers, Auxiliary Hles, Card Holders (1) Hle Lock Devices (HL HL-S) These devices are used to lock the circuit breakers in the ON or OFF position. If overcurrent flows while the circuit breaker is locked, it will trip. Model HL (red resin moldings) to be fitted to hles Model HL-S to be secured on circuit breaker covers are available. (Use a commercially available padlock having the nominal size shown in the right table. If a padlock in another size is used, the device may not lock correctly.) Table 33 HL Applicable model Type name Reference MCCB ELCB diagram HL-05FH NF30-CS Fig. 4 HLN-05SV HLF-05SV NF32-SV, NF63-CV/SV/HV NF125-CV/SV/HV/UV, NF125-SEV/HEV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-CV/SV/HV/UV, NF250-SEV/HEV NF250-SGV/LGV/HGV/RGV NF32-SV, NF63-CV/SV/HV NF125-CV/SV/HV/UV, NF125-SEV/HEV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-CV/SV/HV/UV, NF250-SEV/HEV NF250-SGV/LGV/HGV/RGV NF125-SVU/HVU NF250-SVU/HVU NV32-SV, NV63-CV/SV/HV NV125-CV/SV/HV, NV125-SEV/HEV NV250-CV/SV/HV, NV250-SEV/HEV NV32-SV, NV63-CV/SV/HV NV125-CV/SV/HV, NV125-SEV/HEV NV250-CV/SV/HV, NV250-SEV/HEV NV125-SVU/HVU NV250-SVU/HVU HLF-05SVU HLF-2SWU NF225-CWU HL-4CW (*1) NF400-CW NV400-CW HL-4SW (*1) NF400-SW/SEW/HEW/REW/UEW NF630-CW/SW/SEW/HEW/REW NF00-CEW/SDW/SEW/HEW/REW/UEW NV400-SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW NV00-SEW/HEW HL-4SWU NF400-SWU/HWU, NF630-SWU/HWU HL (*2) NF0-SEW, NF1250-SEW/SDW, NF1600-SEW/SDW Fig. 3 Notes *1 When a padlock is not used, the device can be used as a lock cover (LC). *2 Place an order for a circuit breaker body combined with the device. Table 34 HL-S Fig. 1 Fig. 2 Padlock Remarks: 1. One lot of HL-4CW HL-4SW contains one piece, one lot of others contains 10 pieces. 2. HLF types are used for OFF lock, HLN types for ON lock. a c C Padlock size (mm) A Application (Nominal size) B a b c or 23 B A Padlock Applicable model (mm) Type name Number of Number of MCCB ELCB poles poles A B C D E F NF32-SV, NF63-CV, NF63-SV HLS-05SV2 (*1) NF63-HV 2P 50 NF125-CV, NF125-SV 2P 57 NF32-SV, NF63-CV, NF63-SV 3P NV32-SV, NV63-HV 3P NF63-HV 75 NF63-SV,NF63-HV 4P NV125-CV, NV125-SV, 75 NF125-CV, NF125-SV 3P 3P NV125-HV HLS-05SV (*1) NF125-HV 2P, 3P NF125-SV, NF125-HV 4P NV125-SV, NV125-HV 4P 6 2 NF125-UV 2P, 3P P NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-CV, NF250-SV, NF250-HV 2P NF250-SGV/LGV/HGV/RGV NV125-SEV, NV125-HEV NF125-SEV, NF125-HEV NV250-CV, NV250-SV, NF125-SGV/LGV/HGV/RGV NV250-HV 3P 63 3P NF250-CV, NF250-SV, NF250-HV NF160-SGV/LGV/HGV NV250-SEV, NV250-HEV HLS-2SV (*1) NF250-SEV, NF250-HEV NF250-SGV/LGV/HGV/RGV 4 NF125-SEV, NF125-HEV NF125-SGV/LGV/HGV/RGV NV125-SEV, NV125-HEV NF160-SGV/LGV/HGV 4P NV250-SV, NV250-SEV, 4P 33 NF250-SV, NF250-HV, NF250-SEV, NF250-HEV NV250-HEV NF250-SGV/LGV/HGV/RGV NF250-UV 2P, 3P P HLS-03SVU (*1) NF50-SVFU 2P, 3P NV50-SVFU 2P, 3P HLS-05SVU2 (*1) NF-CVFU 2P 50 HLS-05SVU (*1) NF-CVFU 3P NV-CVFU 3P NF125-SVU/HVU 2P, 3P NV125-SVU/HVU 3P 6 HLS-05SVU (*2) NF125-SVU/HVU 2P, 3P NV125-SVU/HVU 3P 75 6 HLS-2SVU (*1) NF250-SVU/HVU 3P NV250-SVU/HVU 3P 32 4 Fig. 2 Fig. 4 Reference diagram Fig. 5 Fig. 9 Fig Fig. 5 HLS-2SWU (*1) NF225-CWU 3P 3P 4 32 Fig. 6 HLS-4SW (*3) NF400-CW/SW/SEW/HEW/REW NF630-CW/SW/SEW/HEW/REW 2P, 3P, 4P NV400-CW/SW/SEW/ HEW/REW NV630-CW/SW/SEW/ HEW 3P, 4P HLS-4UW (*3) NF400-UEW 3P HLS-SW (*3) NF00-CEW/SDW/SEW/HEW/REW 2P, 3P, 4P NV00-SEW/HEW 3P, 4P HLS-UW (*3) NF400-UEW 4P NF00-UEW 3P, 4P Notes *1 For locking in OFF position *2 A, B, C D in Figs. 5 6 are drilling sizes in front plate. *3 Terminal covers cannot be fitted. Fig. 7 Fig. Fig. 1 C Fig. 3 Padlock b

91 Low-Voltage Circuit P.664 Magnetic Contactor Starters P R1 cl C C C cl cl cl A 72 cl cl 13 R1 B A B R1 Circuit breaker Fig cl D A 6 cl 210 Pan head tapping screw B E F Circuit breaker 36 Line side Load side Circuit breaker cl cl cl A B R1 C 20 cl cl Padlock cl C A B R1 cl D C Fig. 6 Circuit Pan head breaker cl tapping screw 32 Spacer 36 Circuit breaker 20 cl Pan head screw Line side E F R1 A B E F f5.5 Load side Fig. 7 Fig. Fig. 9 (2) Lock Covers (LC) Lock Cover is a plug-in lock for indicating easily without using padlocks that it is prohibited to operate the circuit breaker. A Caution tag can be hung on it. The covers are red resin moldings. Table 35 LC Applicable model Type name MCCB ELCB LC03CS NF30-CS LC-05SV LCBH1R (red) BH-P(1P) LCBH1Y (yellow) LCBH2R (red) BH-P(2P) LCBH2Y (yellow) LCBH3R (red) BH-P(3P) LCBH3Y (yellow) NF32-SV NF63-CV/SV/HV NF125-CV/SV/HV/UV NF125-SEV/HEV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-CV/SV/HV/UV NF250-SEV/HEV NF250-SGV/LGV/HGV/RGV NV32-SV NV63-CV/SV/HV NV125-CV/SV/HV NV125-SEV/HEV NV250-CV/SV/HV NV250-SEV/HEV Remark: 1. One lot of LCBH, LCBL LCNVL contains 50 pieces, one lot of other models contains 10 pieces. LC-05SW to LC-2SW LCBH1 LCBH2, 3 (3) Auxiliary Hles (HT) These hles facilitate opening closing circuit breakers. Table 36 HT Type name Applicable model HT-4CW NF400-CW, NV400-CW (*1) NF400-SW/SEW/HEW/REW/UEW NF630-CW/SW/SEW/HEW/REW HT-4SW NF00-CEW/SDW/SEW/HEW (*1) NF00-REW/UEW (*2) NV400-SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW NV00-SEW/HEW NF0-SEW HT-10SW NF1250-SEW/SDW NF1600-SEW/SDW B C D E 77.5 (4) Card Holders (CH) Cards showing the circuit breaker name circuit number can be inserted to the card holder. Fit the card holder to the circuit breaker body or the flush plate in the flush frame. (Although a card holder is supplied with each circuit breaker body, the card holder is available as an optional part.) A M M4 Table 37 Card holder size (mm) Auxiliary Hles Outline dimension drawing Notes *1 HT can be supplied separately. The user can fit it to the circuit breaker. (One lot contains 1 piece.) *2 1-pole circuit breakers with 00A frame NF400-UEW come with auxiliary hles as stard accessories. C B A Applicable model NF250-SV or below NV250-SV or below NF400-SW or above NV400-SW or above Type name CH-P No.5 CH-P No.3 A 44 3 B fd A C 5 5 O N B C Card size E screw Other

92 752 Low-Voltage External Other Mechanical Interlocks (MI) This mechanical interlock device is used to enable one of two circuit breakers to turn on. Install the device on the panel. Mechanical interlocks to be installed directly to circuit breaker bodies can be manufactured. Consult us for details. DFront, D rear plug-in types Front, rear plug-in types (Panel mounting) These interlocks can be locked with padlocks. B E D P A 22 Stroke Outside Dimension Diagram 4f (f5.5 f7.5 countersunk (rear) use M50. flat countersunk head screws (*2) Drilling Dimension Diagram C Table 3 Table of variable dimensions 1.5 Center of mechanical interlock Center of mechanical interlock Center of circuit breaker Panel plate thickness (t1 to 3.2) (*1) (Gap between circuit breaker panel) Machine this part according to the front plate drilling dimensions of the main breaker Center of mechanical interlock Center of circuit breaker Front, rear plug-in types (Panel mounting) B 22(30) 31(40) 15.5 (20) 44(55) () A 50(0) P Stroke C Panel plate thickness (t1.6 to 3.2) 1.5 (Gap between circuit breaker panel) Outside Dimension Diagram The values in parentheses apply to NF1600-SEW, NF1600-SDW Drilling Dimension Diagram Center of mechanical interlock Center of circuit breaker 4f (f5.5 f7.5 Machine this part according to the countersunk (rear) front plate drilling dimensions use M50. flat of the main breaker countersunk head screws (*2) Center of mechanical interlock Center of circuit breaker mountiong (front) Type name J Type name F G H Type name MI-05SVFB MI-05SVFB MI-4SWFB3 MI-05SWHFB MI-1SVFB2 45 MI-1SVFB MI-SWFB3 MI-2SVFB CL CL Mechanical interlock J Mechanical interlock Mechanical interlock Mechanical interlock mounting plate mounting plate 120 P mounting plate Stroke 15 Stroke 47.5 Stroke 120 CL Circuit breaker Notes *1 For 400A frame or above, use a panel 1.6 to 3.2 thick. *2 When the panel is 2.3 or more thick, countersink the panel (rear side) in f9.5 for the four f5.5 holes. H 43.5 Outside Dimension Diagram 111 CL CL F Circuit breaker F 44 Drilling Dimension Diagram (breaker mount) Fig. 1 Fig. 2 Fig. 3 Circuit breaker M40.7 or f5 screw Mechanical interlock Applicable model Pitch (P) (*1) (mm) 120 CL F Terminal covers cannot be fitted. G Circuit breaker M40.7 or f5 screw CL CL F Reference diagram Mechanical interlock P G CL F mount (*3) Type name Stard Semi-stard Stard MCCB ELCB (*6) t A B C D E Type name 2P 3P 3P Type name 4P 2P 3P NF32-SV, NF63-CV/SV/HV MI-05SVFB2 MI-05SV3 120 NF32-SV, NF63-CV/SV/HV NV32-SV, NV63-CV/SV/HV MI-05SV MI-05SVFB3 (*4) (Fig. 3) NF125-CV/SV MI-1SVFB2 NF125-CV/SV/HV NV125-CV/SV/HV MI-05SV MI-1SVFB MI-1SV4 NF125-UV (*4) NF125-SEV/HEV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-CV/SV/HV, NF250-SEV/HEV NF250-SGV/LGV/HGV/RGV NV125-SEV/HEV NV250-CV/SV/HV NV250-SEV/HEV MI-05SV3 120 (*4) MI-2SV4 150 (*4) (*2) P G M6 or f7 screw Reference diagram (3P) MI-2SVFB3 (Fig. 3) 5 (Fig. 1) NF250-UV 25.5 NF225-CWU MI-05SWU3 120 (*4) NF400-CW/SW/SEW/HEW/REW NF630-CW/SW/SEW/HEW/REW NV400-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW 190 MI-4SW MI-4SWFB3 MI-4SW NF400-UEW (3P) 190 (*2) 3.5 (Fig. 3) NF00-CEW/SDW/SEW/HEW/REW NV00-SEW/HEW MI-SWFB3 NF400-UEW (4P) MI-SW3 240 MI-SW NF00-UEW NF0-SEW, NF1250-SEW/SDW MI-10SW3 220 MI-10SW (Fig. 2) NF1600-SEW/SDW MI-16SW3 315 MI-16SW4 426 (*5) Notes *1 Specify the circuit breaker mounting pitch (P). *2 No need to specify the panel thickness (t). (Usable panel thickness range: t = 1~3.2mm. Above 400AF, use panel thickness t = 1.6~3.2mm) *3 Terminal covers cannot be fitted. (However, TCL-4SW3 can be fitted.) *4 When UVT is provided, separately install the module. *5 If the thickness is not 2.3, specify the panel thickness (t). *6 For NV with TBL, use a circuit breaker with MG. Remarks: 1. When a mechanical interlock is installed on the panel, screw type terminal covers cannot be installed. 2. These devices do not provide an isolation function. However, 400, 600, A frame circuit breakers can be made conforming to it. (See Note 3.) 3. On a 2-pole circuit breaker obtained by removing the neutral pole conductor from a circuit breaker, the mechanical interlock can be installed in the same manner as on a circuit breaker.

93 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Boxes for Boxed (1) Kinds specifications Table 39 MCCB (*2) ELCB (*2) Appearance NF30-CS NF32-SV, NF63-CV/SV/HV NF125-CV/SV NF125-HV NF125-SGV/LGV NF160-SGV/LGV NF250-SGV/LGV NF250-CV/SV, NF125/250-SEV NF125/160/250-HGV NF250-HV, NF125/250-HEV NF400-CW NF400-SW/SEW NF630-CW/SW/SEW NF00-CEW/SDW/SEW NV32-SV, NV63-CV/SV/HV NV125-CV/SV NV125-HV NV250-CV/SV, NV125/250-SEV NV250-HV, NV125/250-HEV NV400-CW NV400-SW/SEW NV630-CW/SW/SEW NV00-SEW Operating method Stard paint color Protection class (IEC 60529) 2, 3P 2P 3P 2P 3P 2, 3P 2, 3P d Selection of rated current When selecting the rated current of circuit breaker, it is necessary to consider the temperature in the box. When the rated current is carried, the temperature in the box increases by 10 to 20K. Correct the rated current with the temperature correction curve. Determine the maximum working current to be 0% or less of the rated current. d Locking Type I W boxed circuit breakers can be provided with locks in the following parts. Locking can prevent unnecessary operation. qcover case won or OFF position of operating hle Padlocks must be prepared by the user. The dimensions of the padlocks are shown on page P 3P 3P Closed type (S) (*1) (*1) NFS-03CS NFS-05SV2 (*5) NFS-05SV NFS-1SV2 (*5) NFS-1SV NFS-2SV Notes *1 The window frame varies depending on the model. *2 For 1-pole circuit breakers, boxes are not manufactured. *3 The protection class of NFI-1SV NFI-2SV is IP3X. *4 The protection class of NFW-4CW, NFW-4SW, NFW-6SW NFW-SW is IP54. *5 The circuit breaker body is a 2-pole external type. Remarks: 1. Only internal accessories with lead wires drawn out can be fitted. (However, LT SLT can be fitted on the right pole side.) 2. The dust-proof type (I) models do not provide an isolation function. Dust-proof type (I) Water-proof type (W) NFI-4CW NFW-4CW NFI-4SW NFW-4SW NFI-6SW NFW-6SW NFI-SW NFW-SW NFS-05SV NFI-05SV NFS-05SV NFW-05SV NFS-1SV NFW-1SV NFI-1SV NFS-1SV NFW-1HV NFS-2SV NFI-2SV NFW-2SV NFI-4CW NFW-4CW NFI-4SW NFW-4SW NFI-6SW NFW-6SW NFI-SW NFW-SW Direct operation of circuit breaker hle Operation through operating hle mechanism Box: Munsell 5Y7/1 Operating hle: Munsell N1.5 IP3X IP4X (*3) IP65 (*4) NFI-05SV NFI-1SV NFI-2SV NFW-05SV NFW-1SV NFW-1HV NFW-2SV d Interlock (only for Dust-proof type) The cover cannot be opened while the circuit breaker is in the ON state. However, if the interlock release screw is turned, the cover is released from the locked state can be opened even in the ON state. d Hle operation display The ON, OFF or trip state of the body is displayed on each position on the decorative board. Other Example of Type I operating hle block

94 754 Low-Voltage External (2) External dimensions JMCCB J F B 3 mounting holes fg (key slot) J 4 mounting holes fg (key slot) H E A D C K, hole 2 pcs. on bottom Fig. 1 Type S Screw M6 Earth terminal F B J 4 mounting holes fg H E A K, hole D C Fig. 3 Type I 4 mounting holes fg Earth terminal NFI-05SV NFI-1SV,NFI-2SV NFI-4CW to NFI-SW 2 pcs. on bottom 630A or below: 2 pcs. on each of top bottom 00A: 3 pcs. on each of top bottom 4 mounting holes fg E A E A E A F B D C Screw M6 Earth terminal F B D C F B D C Other Table 40 Table of variable dimensions (Boxes for circuit breakers are not manufactured.) Box type S I W Type name NFS-03CS NFS-05SV2 NFS-05SV NFS-1SV2 NFS-1SV NFS-2SV NFI-05SV NFI-1SV NFI-2SV NFI-4CW NFI-4SW NFI-6SW NFI-SW NFW-05SV NFW-1SV NFW-1HV NFW-2SV NFW-4CW NFW-4SW NFW-6SW NFW-SW J H K, hole 2 pcs. on bottom Fig. 2 Type S Applicable Model NF30-CS NF32-SV, NF63-CV/SV/HV NF125-CV/SV NF125-CV/SV/HV NF250-CV/SV, NF125/250-SEV NF125-SGV/LGV NF160-SGV/LGV NF250-SGV/LGV NF32-SV, NF63-CV/SV/HV NF125-CV/SV/HV NF250-CV/SV/HV, NF125/250-SEV/HEV NF125-SGV/LGV/HGV NF160-SGV/LGV/HGV NF250-SGV/LGV/HGV NF400-CW NF400-SW/SEW NF630-CW/SW/SEW NF00-CEW/SDW/SEW NF32-SV, NF63-CV/SV/HV NF125-CV/SV NF125-HV NF250-CV/SV/HV, NF125/250-SEV/HEV NF125-SGV/LGV/HGV NF160-SGV/LGV/HGV NF250-SGV/LGV/HGV NF400-CW NF400-SW/SEW NF630-CW/SW/SEW NF00-CEW/SDW/SEW K socket, 1 pc. on each of top bottom Fig. 4 Type W Note) The sockets are applicable to thick steel duct (JIS C 305) conduit tube thread. Variable dimensions Fig. A B C D E F G H J K , 2 2, 35, H J H Earth terminal Fig. 5 Type W K socket 630A or below: 1 pc. on each of top bottom 00A: 2 pc. on each of top bottom , 35, 44 50, 62, 7 2, 35, 44 2, 35, 44 50, 62, 7 50, 62, 7 50, 62,

95 Low-Voltage Circuit P.664 Magnetic Contactor Starters P JELCB J F B J 3 mounting holes fg Fig. 1 Type S D C K, hole: 2 pcs. on each of top bottom 3 mounting holes fg (key slot) (NVS-03CS) 4 mounting holes fg (key slot) H E A Earth terminal F B J 4 mounting holes fg H E A D Earth terminal C K, hole NFI-05SV NFI-1SV 2 pcs. on bottom NFI-2SV 630A or below: 2 pcs. on each of top bottom NFI-4CW to NFI-SW 00A: 3 pcs. on each of top bottom Fig. 3 Type I 4 mounting holes fg 4 mounting holes fg F B J H Earth terminal E A D C K socket 630A or below: 1 pc. on each of top bottom 00A: 2 pc. on each of top bottom Fig. 5 Type W Table 41 Table of variable dimensions (Boxes for circuit breakers are not manufactured.) Box type S I W Type name NFS-05SV2 NFS-05SV NFS-1SV2 NFS-1SV NFS-2SV NFI-05SV NFI-1SV NFI-2SV NFI-4CW NFI-4SW NFI-6SW NFI-SW NFW-05SV NFW-1SV NFW-1HV NFW-2SV NFW-4CW NFW-4SW NFW-6SW NFW-SW F B J H Fig. 2 Type S E A D C K, hole: 2 pcs. on bottom Applicable Model Screw M6 Earth terminal NV32-SV, NV63-CV/SV/HV NV125-CV/SV NV125-CV/SV/HV NV250-CV/SV, NV125/250-SEV NV32-SV, NV63-CV/SV/HV NV125-CV/SV/HV NV250-CV/SV/HV, NV125/250-SEV/HEV NV400-CW NV400-SW/SEW NV630-CW/SW/SEW NV00-SEW NV32-SV, NV63-CV/SV/HV NV125-CV/SV NV125-HV NV250-CV/SV/HV, NV125/250-SEV/HEV NV400-CW NV400-SW/SEW NV630-CW/SW/SEW NV00-SEW F B Note) The sockets are applicable to thick steel duct (JIS C 305) conduit tube thread. Variable dimensions Fig. A B C D E F G H J K E H A D C Fig. 4 Type W K socket, 1 pc. on each of top bottom , 35, 44 2, 35, 44 50, 62, 7 2, 35, 44 2, 35, 44 50, 62, 7 50, 62, 7 50, 62, Other

96 756 Low-Voltage External Other Electrical Operated Electrical Operation Devices (1) DElectrically D operated circuit breakers Table 42 Spring charge type (1) Spring charge type (2) Motor-drive type (2) Stard paint color: Munsell 5Y7/1 Stard paint color: Munsell 5Y7/1 Specify the electrical operation device together with the circuit breaker body. Electrically operating method Spring charge type (1) Spring charge type (2) Motor-drive type (2) MCCB ELCB Class S, H R Class C Class U NF125-SV, NF125-HV NF125-SEV, NF125-HEV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-SV, NF250-HV NF250-SEV, NF250-HEV NF250-SGV/LGV/HGV/RGV NF125-RV, NF250-RV NF125-CV NF250-CV NF125-UV NF250-UV NF400-SW, NF400-SEW NF400-HEW, NF400-REW NF630-SW, NF630-SEW NF630-HEW, NF630-REW NF00-SDW, NF00-SEW NF00-HEW, NF00-REW NF400-CW NF630-CW NF00-CEW NF400-UEW NF00-UEW NF0-SEW NF1250-SEW NF1250-SDW NF1600-SEW NF1600-SDW NF400-SW, NF400-SEW NF400-HEW, NF400-REW NF630-SW, NF630-SEW NF630-HEW, NF630-REW NF00-SDW, NF00-SEW NF00-HEW, NF00-REW NF0-SEW NF1250-SEW NF1250-SDW NF1600-SEW NF1600-SDW Notes *1 When the rated operating voltage is 24 V DC or 4 to 60 V DC, specify the voltage. If the voltage is not specified, the circuit breaker will be manufactured for to 240 V AC to 250 V DC. *2 For 24-V DC circuit breakers, the operating time at a voltage of % or more is shown. *3 Models for special voltage (125 V DC or 240 V AC) are not provided with the test button. Remarks: 1. Flush plate type circuit breakers can be manufactured to order. 2. The models with voltage in parentheses are special voltage products. 3. For the spring charge type (1), use an ON-OFF operating switch for minute load. 4. For the spring charge type (1) The circuit breaker of 3 pole can be used TC-S, TC-L, TTC, BTC PTC. In case of 125A frame 4 pole can be used only TC-L. In case of 250A frame 4 pole can be used TC-S, TC-L, TTC, BTC PTC. 5. When the body of the spring charge type (1) breaker is an earth leakage alarm breaker, the reset button cannot be pressed. Provide such a circuit breaker with an external reset or automatic reset system (except for the electronic type). 6. When the body of the motor-drive type (2) or spring charge type (2) has internal accessories, they are normally provided with lead wire terminal blocks. 7. The types other than the spring charge type (1) do not provide an isolation function.. When placing an order for a CE marked product of the spring charge type (1) or spring charge type (2), specify the model name with CE. 9. The switching durability of electrically operated circuit breakers conforms to JIS. NF400-CW NF630-CW NF00-CEW NF400-UEW NF00-UEW Motor breakers NF125-SV, NF250-SV Class S, H R Class C NV125-SV, NV125-HV NV125-SEV, NV125-HEV NV250-SV, NV250-HV NV250-SEV, NV250-HEV NV125-CV NV250-CV NV400-SW, NV400-SEW NV400-HEW, NV400-REW NV630-SW, NV630-SEW NV630-HEW, NF00-SEW NV00-HEW NV400-CW NV630-CW NV400-SW, NV400-SEW NV400-HEW, NV400-REW NV630-SW, NV630-SEW NV630-HEW, NF00-SEW NV00-HEW (*3) NV400-CW(*3) NV630-CW Motor breakers NV125-SV, NV250-SV Rated operating voltage (V) Compatible with to 240 V (Allowable operating voltage range: AC to 250 V DC 5 to 110%) 24 V DC, 4 to 60 V DC (*1) DC-110, AC-110 AC (DC125, AC240) DC-110, AC-110, AC (DC125, AC240) Operating DC /110V ON (1.5) 3.0(.0) 5.0(13.5) OFF 1.0 (3.0) 1.0 (4.0) current (Ams) /110V ON (3.0) 4.0(.0) 5.0(10.0) Values in OFF 1.0 (3.0) 1.0 (3.0) ( ): Starting AC current 200/220V ON 0.5 (2.5) 2.0(4.5) 3.5(7.0) OFF 0.5 (1.5) 0.5 (1.5) ON 0.05~0.1(*2) or less Operating s OFF 0.6 or less (self-holding type) (self-holding type) time 3 or less (self-holding type) Charge 1.2 or less (self-holding type) Required transformer capacity VA Endurance voltage 1500V 1500V DElectrical D operation devices Table 43 Electrically operating method Applicable models Rated operating voltage Compactible to -240VAC/-250VDC 24VDC NF125-CV/SV/HV MDSAD240-NF1SVE MDSD024-NF1SVE The following models of Electrical Operation Devices are supplied also as separate devices. The user can install them to the circuit breaker body. (Front connection, rear connection plug-in types) (When requiring a motor breaker or a CE marked product, place an order for it together with the circuit breaker body.) NV125-CV/SV/HV MDSAD240-NV1SVE MDSD024-NV1SVE Spring charge type (1) NF125-SEV/HEV/SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-CV/SV/HV/UV/SEV/HEV/SGV/LGV/HGV/RGV NF250-UV MDSAD240-NF2SVE MDSD024-NF2SVE NV250-CV/SV/HV MDSAD240-NV2SVE MDSD024-NV2SVE NV125-SEV/HEV NV250-SEV/HEV MDSAD240-NVE2SVE MDSD024-NVE2SVE 4-60VDC MDSD060-NF1SVE MDSD060-NV1SVE MDSD060-NF2SVE MDSD060-NV2SVE MDSD060-NVE2SVE

97 Low-Voltage Circuit P.664 Magnetic Contactor Starters P DCautions D DDAll electrical operations are based on intermittent rating. Avoid operating any device continuously 10 times or more (ON OFF operations are counted as one time). DDOperate any device at 5 to 110% of the rated operating voltage. DDThe dielectric strength of electrical operation circuits is 1500 V. When performing dielectric strength test of any of these devices other devices, if the test voltage exceeds the rated value (1500 V), disconnect the operation power supply terminal. DDWhen collectively operating more than one electrical operation device, isolate the devices connecting a relay to each device. If the control terminals are directly connected in parallel, a circuit will be formed, the devices may not normally function. DAutomatic D reset (optional) The automatic reset type has a built-in alarm switch in the circuit breaker is connected in such a way that the OFF operation circuit is closed when the circuit breaker trips. Therefore, when the circuit breaker trips, it is automatically reset. However, when the circuit breaker thermally trips, it may not be automatically reset. If an automatic reset spring charge type (1) is required, the user must wire the device in accordance with the external connection diagram shown in Fig. 1 in (3). (2) connection (List of manufacturable) Table 44 Frame (A) connection method 50~ ~00 0, Front connection type (3) Structure operation JSpring J charge type (1) Rear connection type Plug-in type (*1) (*2) Notes *1 For ELCB, only circuit breakers with a frame size of 125 to 400 A can be manufactured. *2 In the case of 125 A frame circuit breakers U class, the circuit breakers are supplied as special models. Consult us for details. Remarks: 1. All models of the front connection type are provided with bar terminals (except the spring charge type (1)) pole circuit breakers of all models are obtained by removing the neutral pole conductors from circuit breakers. DDElectrical operation When the ON operation switch is closed, the relay will operate, the motor will be driven, the latch mechanism will be released, the closing spring force will instantaneously turn on the circuit breaker. When the OFF operation switch is closed, the relay will operate, the motor will be driven, the circuit breaker will be turned off (reset),, at the same time, the closing spring will be charged. Note: The charge may not be completed because the circuit protective function operates. DDManual operation After turning the MANUAL/AUTO selection switch on the cover upper surface to MANUAL, press the ON button, the latch mechanism will be released, the closing spring force will instantaneously turn on the circuit breaker. After turning the MANUAL/AUTO selection switch on the cover upper surface to MANUAL, draw out the manual hle, move it upward downward about 10 to 14 times. Then, the circuit breaker will be turned off (reset),, at the same time, the closing spring will be charged. Although the circuit breaker can be turned off even if the switch is not turned to MANUAL, the selection switch should be set to MANUAL because remote operation may be accepted. After turning the changeover switch to MANUAL, draw out the OFF lock plate, lock the circuit breaker in the OFF state with padlocks (to be prepared by the user). Up to three padlocks can be fitted. f5 to f padlocks can be fitted. Note: After the completion of manual operation (on-site operation), return the selection switch to AUTO without fail. If it is not returned, electrical operation (remote operation) cannot be performed. DDDisplay of tripping state When the circuit breaker trips in the ON state, the tripping state is displayed. When it trips in the OFF state, the OFF state is kept displayed. Note: When it trips in the OFF state, signals from AL will not be output. DCautions D for use q To the ON or OFF operation switch (to be prepared by the user), current only of 24 V DC 15 to 30 ma flows. Use a switch for minute load. w Operate the operation switch for 0.1 s or more to turn on for 20 ms or more to turn off. If it is operated for less than the time, it may not function. The wire to the operation switch shall be less than m. e The power supply module has a built-in switching power supply. Therefore, it may interfere with communication devices near the module. In such a case, install a noise filter on the input side. r For the automatic reset type, purchase a circuit breaker with alarm switch (for minute load), connect the signal circuit (among the terminal numbers S1, S2 S4) as shown in Fig. 1. If the circuit breaker in the OFF state is tripped by UVT-N or the like, it cannot be automatically reset. To reset it, it is necessary to turn it on under no current. After this operation, it will be automatically reset. Operating power supply Uc P1 P2 Fig. 1 ON Operation circuit Power supply module Uc OFF P1 P2 S1 S2 S4 Power supply module AL (for minute load) AL a (alarm switch for minute load) Control SW1 S1 circuit M Motor S2 ON S4 SW2 OFF (RESET) The circuit breaker is off, the electrical operation device is in the charged state. Symbol SW1 SW2 M Power supply circuit Electrical operation base SW1 MANUAL/AUTO selection switch M SW2 Charge/Discharge detecting switch Interpretation of symbol MANUAL/AUTO selection switch Limit switch (For spring condition detection charge/discharge) Motor Note *1 When power is applied, inrush current (capacitor charging current) of 60 A flows to the breaker fuse installed on the power supply circuit for 1 ms or so. When selecting the breaker fuse, make sure that they will not cause problems, such as blowout malfunction. Other

98 75 Low-Voltage External JMotor-drive J type (2) DDElectrical operation Forward reverse motor rotation is changed by ball screw to switch the breaker ON OFF (reset). DDManual operation The manual operation hle can be used to switch the breaker ON OFF directly. DDCautions for use q In the case of a circuit breaker with UVT, if the circuit breaker trips owing to the operation of UVT, the procedure for re-closing the circuit breaker varies depending on the condition of the electrical operation device before the circuit breaker trips. Tripping in ON state: Reset (OFF). Turn on. Tripping in OFF state: Turn on (idle tripping). Reset (OFF). Turn on. (If the circuit breaker cannot be turned on (idle tripping), reset (OFF) it, turn on.) When an automatic reset system is configured on a non-reset type circuit breaker with UVT, if UVT is set to the no-voltage state, the operations to turn off (reset), trip, turn off (reset) trip are repeated. Operation circuit 1 NF400-CW~NF00-UEW NV400-CW~NV00-HEW Therefore, configure the circuit in such a way that power is disconnected from the electrical operation device before the circuit breaker is tripped by the non-reset type UVT. w Current of about 0.2 A will flow to the ON-OFF switch. Use an appropriate switch. e Do not apply ON OFF operation signals continuously. An interval of 0.5 sec or more is necessary between ON OFF signals. r In the case of the automatic reset type device, it will perform the reset operation with an interval of 0.5 sec after NFB performs the tripping action. t The electrical operation device has a built-in pumping preventing circuit. Therefore, it can operate to turn off the circuit breaker while the ON operation switch is held in the closing state, but it cannot turn on continuously after turning off. To turn on, once turn off the ON operation switch, turn on the switch. Do not apply the ON operation signal continuously. y The manual operating hle moves at a high speed during electrical operation. Pay attention to the hle. Keep the operation circuit power supply off during manual operation. u In the manual operation, surely turn the manual operating hle to the position indicated on the nameplate. DDOperation circuit For the automatic reset type, the connections indicated with the dashed lines are added. Operation circuit 2 NF0-SEW~NF1600-SEW Other (DC-) Operating power supply ON OFF Reset ALa Internal connection (when circuit breaker is off) G (Earth terminal) Z2 A1 R3 R4 M R1 R2 Z1 LS A2 Z T1 X X1 Y1 Y Z4a Z4b B T1b T2 Z3 R Y2a C D Alarm switch for automatic reset (a contact) M : Motor Z, K: Exciting coil of keep relay X : Relay for ON operation (Operation circuit 3) Y : Relay for OFF operation LS, LS1, LS2: Limit switches R : Motor driving relay X1~X4, Y1~Y4, Y2a, Z4a, Z4b, Z1, Z2, Z3, K1, T1b, T2a: Relay switches Z : Polarity switching relay (Operation circuit 1 or 2) T1 : Pumping preventing timer T2 : Timer for automatic reset (R1)~(R4): Relay switches JSpring J charge type (2) DDElectrical operation When the ON operation switch is closed, the closing coil will be excited to release the latch mechanism, the closing spring force will instantaneously turn on the circuit breaker. When the OFF operation switch is closed, the relay will operate to start the motor, turn off (reset) the circuit breaker, at the same time, charge the closing spring. DDManual operation Press the ON button, the latch mechanism will be released, the closing spring force will instantaneously turn on the circuit breaker. Turning off (resetting) Push the leaf spring, bring out the manual hle, move the hle upward downward more than ten times. Then, the circuit breaker will be turned off (reset),, at the same time, the closing spring will be charged. DDCautions for use q In Before installing or removing the electrical operation device to or from the circuit breaker, trip the circuit breaker, discharge the electrical operation device. After the device is installed to the circuit breaker, the device will not trip the circuit breaker in the OFF state even if the trip button is pressed. This is not a trouble. The electrical operation device takes 3 seconds to turn off the circuit breaker. To open the circuit immediately by remote operation, use a circuit breaker with SHT or UVT. The device has a built-in pumping preventing relay. w Current of about 9 A 0.2 A will flow to the ON OFF switches, respectively. Use appropriate switches. T2 LS3 (DC-) Operating power supply M ON OFF Reset X Internal connection (when circuit breaker is off) G (Earth terminal) X2 A1 A2 B C D ALa Internal connection (when circuit breaker is off) G Internal structure of spring charge type X P2 P1 Operating power supply (DC - ) LS2 Y X Y S2 ON T1 X1 X4 Y2 Y1 Y4 X3 Z1 M Y3 Z X T1b LS Y T2a T2 Alarm switch for automatic reset (a contact) CC Y LS1 S4 OFF RESET Z2 : Motor field coil : Surge absorbing circuit : Surge absorber Internal structure of motor-drive type DOperation D circuit For the automatic reset type, the connections indicated with the dashed lines are added. CC : Coil for making Y : Relay for pumping prevention X : Relay for self-sustaining on OFF side LS1 : Limit switch interlocking with cam LS2 : Limit switch interlocking with cam LS3 : Limit switch interlocking with OFF lock plate M : Motor Alarm switch for automatic resetting (contact a)

99 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Distribution Board Mounting Parts, Lock Covers Hle Caps DBPA-type D mounting base (for BH-P) Single-phase-type Mtg. holes 4.5 dia. Solderless terminal for wire size 22~60mm A Note: Single-phase tvpes have no central pole A 21 Solderless terminal for wire size : 125A 14~50mm 2 250A 22~125mm 2 Three-phase-type Max. no. of ways 1ph, 2w 1ph, 3w 3ph, 4w Main : 125A Main : 125A Main : 250A Main : 125A Main : 250A Neutral terminal 6 BPA-1106 BPA-2106 BPA-3106 NT-06 9 BPA BPA-1112 BPA-2112 BPA-3112 NT BPA BPA-111 BPA-211 BPA-221 BPA-311 BPA-321 NT-1 24 BPA-2124 BPA-2224 BPA-3124 BPA-3224 NT BPA-2230 BPA-3230 NT BPA-2236 BPA-3236 NT BPA-3242 NT-42 DMounting D plate (for BH) Breakoff undercut = 00 ± 1 5.5ø mtg. holes Mounting pitch wide mtg. slot Line side Line side BH MCB (mm) Spring clip One mounting plate has 32 circuits. One package includes 10 mounting plates (320 circuits). DLock D covers hle caps (for 1-pole, 2-pole types) Many panelboards include some restricted-operation circuits, which must either normally remain on, such as allnight lighting or alarms, or must remain off, such as spare circuits, or circuits used in repair or construction work. for such circuits can be locked by simply installing a lock cover on the hle a) Lock cover for 1-pole units 33 Colors available (63.3) ( ) : 3P b) Lock cover for 2-pole, units c) Hle cap for 1-pole units 9.5 Outlines dimensions (mm) d) Hle cap for 2-pole units Fig. ref. Item Poles Colors Red Yellow Green a) 1 LCBH1R LCVH1Y b) Lock cover 2 LCBH2R LCBH2Y b) 3 LCBH3R LCBH3Y c) 1 HC1R HC1Y HC1G Cap d) 2 HC2R HC2Y HC2G ON OFF Lock cover in place (1-pole unit) ON OFF Lock cover in place (2-pole unit) IEC 35-mm Rail Mounting Adapters Other Table 45 Type name Number of poles of circuit breaker Applicable model MCCB ELCB Fig. DExternal D dimension IEC 35-mm rail mounting adapter DIN-03CS (Note1) DIN-05SV 2, 3 2, 3 NF30-CS NF32-SV NF63-CV/SV/HV NV32-SV NV63-CV/SV/HV Fig. 1 Fig Remark: 1. Place an order in units of 10 pieces. Fig. 1 Fig. 2 1 Mounting hook for IEC 35mm rail [DIN-05SV]

100 760 Low-voltage NF30-CS NF30-CS Operating 3h 2h 1h 40min Model NF30-CS Rated current In (A) 3, 5, 10, 15, 20, 30 Number of poles 2 3 Rated insulation voltage Ui (V) V 500V IEC (Icu/Ics) AC 415V 1.5/1.5 30V 1.5/ V 2.5/2 Rated short-circuit breaking capacity (ka) Stard Attached Parts (Front connection) Types NF30-CS Mounting screw: M (2pcs) 20min 10min 6min 4min 2min Other Internal Left-side mounting 2-pole Operating hle Right-side mounting AL Operating time 1min 40s 30s 20s 10s 6s 4s 2s 1s 0.6s 0.4s 0.2s 0.1s 0.06s 0.04s 0.02s 0.01s AX Min. Max % of rated current Lead wire direction Remark: 1. Stard lead wire is drawn from side. However, lead wire drawn by load can be produced upon request. External Type name Small (TC-S) TCS-03CS3W (*1) Large (TC-L) TCL-03CS3W (*1) Rear (BTC) BTC-03CS3W (*1) Skeleton (TTC) TTC-03CS (*1) Hle lock (HL) HL-05FH Lock cover (LC) LC03CS IEC 35mm rail mounting adapter (DIN) DIN-03CS Terminal cover Note *1 The designation depends on the number of poles. Temperature Curve Operating time change rate (%) Rated ambient temperature Ambient temperature ( C) 50 60

101 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Rear connection Mtg. hole M5 screw f (max.) pole Conductor thickness t=3 max. 2-pole 3 52 Busbar drilling for Drilling plan 67 direct connection Mtg plate t max. = f5 Applicable wire size: f1.6mm to 14mm 2 f5.5 6 M40.7 taps or f5 M40.7 taps or f5 4 2-pole R Mounting base 2-pole 45 (min) 25 (min) M6 screw mtg M40.7 screw pole Drilling plan 76.5 ø Front-plate cutout 1mm clearance on each side of hle IEC Rail Mounting Adapter 35mm IEC-rail adapter for installation pole utensil for 35mm IEC-rail Other

102 762 Low-voltage NF32-SV NF63-CV NF63-SV NF63-HV Model NF32-SV NF63-CV NF63-SV NF63-HV Rated current In (A) 3 4 (5) 6 10 (15) (30) (5) 6 10 (15) (30) (60) (5) 6 10 (15) (30) (60) (15) (30) (60) 63 Number of poles Rated insulation voltage Ui (V) V 2.5/ V 2.5/ / / /7.5 Rated 440V 2.5/ / /7.5 10/ short-circuit IEC AC 415V 2.5/ / /7.5 10/ breaking (Icu/Ics) capacity 400V 5/5 5/5 7.5/7.5 10/ (ka) 30V 5/5 5/5 7.5/7.5 10/ 230V 7.5/ /7.5 15/15 25/19 DC 250V (*1) 2.5/ / / /7.5 Stard attached parts (front connection) Mounting screw: M (2 3P: 2pcs, 4P: 4pcs) Insulation barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs) (*2) Notes *1 Use two poles for three- four-pole products. Not available for use with connection as shown at the bottom of page 672. *2 Supplied with NF63-SV NF63-HV. Other Operating Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s % of rated current Operating characteristics NF32-SV 3A-6A NF63-CV 3A-6A NF63-SV 3A-6A Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min Instantaneous trip current is Max. fixed to AC600±A120A 1min DC50±A1A. Max. 30s 20s Max. total breaking time 10s 5s Min. Min. 2s Max. total breaking time 1s 0.5s 0.2s AC 0.1s DC AC 0.05s DC 0.02s Time-delay trip Instantaneous trip Time-delay trip Instantaneous trip 0.01s Internal Left-side mounting 2-pole 3, NF63-SV Operating hle AL Right-side mounting External AX SHT or UVT Lead-wire direction % of rated current Operating characteristics NF32-SV 10A-32A NF63-CV 10A-32A NF63-SV 10A-32A NF63-HV 10A-32A Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Min. 2 3 Time-delay trip 4 % of rated current Operating characteristics NF63-CV 40A-63A NF63-SV 40A-63A NF63-HV 40A-63A Max. (60A-63A) Max. (40A-50A) Max. total breaking time AC DC Instantaneous trip Temperature Compensation Curve Current rating (%) (Rated ambient 0 temperature 40 C) 10 0 Rated ambient temperature Ambient temperature ( C) Type name Type name 2P F-05SV2 2, 3P MI-05SV3 F Mechanical interlock MI 3, 4P F-05SV 4P MI-05SV4 Operating hle 2P V-05SV2 2P TCS-05SV2 V Small TC-S 3, 4P V-05SV 3P TCS-05SV3 LC LC-05SV TCL-05SV2 2P HLF-05SV TCL-05SV2L Hle lock device HL (*1) HLN-05SV Large TC-L TCL-05SV3 3P HL-S HLS-05SV TCL-05SV3L Terminal Note *1 HLF types are used for OFF lock HLN types for ON lock. 4P TCL-05SV4 cover Skeleton TTC Rear BTC Plug-in PTC IEC 35mm rail mounting adapters DIN-05SV 2P 2P 2P TTC-05SV2 BTC-05SV2 PTC-05SV2 3P 3P 3P TTC-05SV3 BTC-05SV3 PTC-05SV

103 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button Insulation barrier (removable) pole Neutral pole M50. screw (M for 60A 63A) 4 50 f f4.5 Applicable wire size: f1.6 to 22mm 2 (for M50. screw) f5.5 (f.5 for 60A 63A) 12.5 max. (16 max. for (Conductor 60A 63A) thickness t=4 max.) Conductor drilling for direct connection 2-pole M40.7 taps or f5 25 Drilling plan Rear connection 2-pole Mounting plate t = 3.2 max. Mounting base 43 (44 for 60A 63A) M40.7 taps or f5 27 min. 27 min M6 screw 42 (46 for 60A 63A) 50 M40.7 breaker mounting screw 25 2-pole f Drilling plan R1 Front-panel cutout mm clearance on each side of the hle frame Plug-in Mounting plate Plug-in terminal block M50. Terminal block mounting screw (plug-in terminal block) max. Details of terminal M6 screw f pole Conductor drilling 2-pole f6 hole or M50. taps Other Drilling plan Remark: 1. Only 2-pole models are available for NF32-SV NF63-CV.

104 764 Low-voltage NF125-CV NF125-SV NF125-HV NF125-SV Model NF125-CV NF125-SV NF125-HV Rated current In (A) 50 (60) 63 (75) (15) (30) (60) 63 (75) (15) (30) (60) 63 (75) Number of poles Rated insulation voltage Ui (V) V / 10/ 500V 7.5/4 1/1 30/23 Rated 440V 10/5 25/25 50/3 short-circuit IEC AC 415V 10/5 30/30 50/3 breaking (Icu/Ics) capacity 400V 10/5 30/30 50/3 (ka) 30V 10/5 30/30 50/3 230V 30/15 50/50 /75 DC 250V (*1) 7.5/4 40/40 Stard attached parts (front connection) Mounting screw: M (2 3P: 2pcs, 4P: 4pcs) (*2) Insulation barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs) Notes *1 Use two poles for three- four-pole products. If wired as shown at the bottom of page 672, three four poles can be used for up to VDC, respectively. *2 Supplied with NF125-SV NF125-HV. Operating 4h 4h 4h Other Operating time 2h 1h 30min 20min 14min 10min 6min 6min 4min 4min Max. (60A-A) 2min Instantaneous trip current is 2min fixed to AC600±A120A Max. (40A-50A) 1min DC50±A1A. 1min Max. 30s 30s 20s 20s Max. total breaking time 10s 10s 5s 5s Min. 2s Min. 2s Max. total breaking time 1s 1s 0.5s 0.5s AC 0.2s 0.2s DC 0.1s 0.1s AC 0.05s 0.05s DC 0.02s 0.02s Time-delay trip Instantaneous trip Time-delay trip Instantaneous trip 0.01s 0.01s % of rated current Internal Left-side mounting 2-pole 3, Operating hle AL Right-side mounting External Operating characteristics NF125-SV 15A-32A NF125-HV 15A-32A AX SHT or UVT Operating time 2h 1h 30min 20min 14min 10min Lead-wire direction % of rated current Operating characteristics NF125-CV 50A-A NF125-SV 40A-A NF125-HV 40A-A Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Min. 2 3 Time-delay trip 4 Max. Operating characteristics NF125-CV 125A NF125-SV 125A NF125-HV 125A AC % of rated current Max. total breaking time DC Instantaneous trip Temperature Compensation Curve Current rating (%) (Rated ambient 0 10 temperature 40 C) 0 Rated ambient temperature Ambient temperature ( C) Type name Type name 2P F-1SV2 2, 3P MI-05SV3 F Mechanical interlock MI 3, 4P F-1SV 4P MI-05SV4 Operating hle 2P V-1SV2 2P TCS-1SV2 V Small TC-S 3, 4P V-1SV 3P TCS-1SV3 LC LC-05SV 2P TCL-1SV2 Hle lock device HL (*1) HL-S HLS-05SV 2P TTC-1SV2 cover Skeleton TTC Notes *1 HLF types are used for OFF lock HLN types for ON lock. 3P TTC-1SV3 *2 Specify the working voltage. 2P BTC-1SV2 Rear BTC 3P BTC-1SV3 Plug-in PTC Electrical operation device (*2) HLF-05SV 2P Large PTC-1SV2 TC-L 3P TCL-1SV3 HLN-05SV 3P PTC-1SV3 4P TCL-1SV4 Terminal

105 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button Insulation barrier (removable) pole f.5 50 Neutral pole 4 M screw f4.5 Solderless terminal for wire size 14 to 2/0AWG CU/AL Wire connection f.5 19 max. Comb conductor 2-pole 16.5 max. (Conductor thickness t=4 max.) Conductor drilling for direct connection 30 Drilling plan 30 M40.7 taps or f5 111 Rear connection Mounting plate t = 3.2 max. Mounting base 102 Stud can be 52 rotated 90 2-pole 2-pole connection allowance M bolt 112 Insulation tube M40.7 breaker mounting screw f pole M40.7 taps or f5 Drilling plan 112 R1 R1 1.0mm clearance on each side of the hle frame Front-panel cutout 52 Plug-in 5.5 Mounting plate Plug-in terminal block M50. Terminal block mounting nut or screw mounted directly max. 12 (plug-in terminal block) Other Details of terminal M screw pole f.5 Conductor drilling pole Drilling plan f6 hole or M50. taps Remarks: 1. The 2-pole models of NF125-HV are models with the central pole removed. 2. Only 2- models are available for NF125-CV.

106 766 Low-voltage NF125-UV NF125-UV Model Rated current In (A) NF125-UV Number of poles Rated insulation voltage Ui (V) 690 Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts (front connection) AC 690V 10/10 500V 200/ V 200/ V 200/ V 200/200 30V 200/ V 200/200 DC 250V Mounting screw: M (2 3P: 2pcs, 4P: 4pcs) M (2 3P: 2pcs) Operating 4h 4h 4h 2h 2h 2h Other Operating time 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. Max. Operating characteristics NF125-UV 15A-30A Instantaneous trip current is fixed to 600A ± 120A. Max. total breaking time 0.02s Time-delay trip Instantaneous trip 0.01s Internal Left-side mounting Operating hle Operating time 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. Operating characteristics NF125-UV 40A-A Max. (60A-A) Max. (40A-50A) Max. total breaking time 0.02s Time-delay trip Instantaneous trip 0.01s Operating time 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Min. Time-delay trip Max. Operating characteristics NF125-UV 125A Max. total breaking time Instantaneous trip % of rated current % of rated current % of rated current AL Right-side mounting External AX SHT or UVT EAL TBL TBM MG Lead-wire direction Temperature Compensation Curve Current rating (%) (Rated ambient 0 temperature 40 C) 10 0 Rated ambient temperature Ambient temperature ( C) Type name Type name F F-1UV 2, 3P MI-05SV3 Operating hle V V-1UV Mechanical interlock MI 4P MI-05SV4 Lock cover LC LC-05SV Small TC-S 3P TCS-1SV3 HLF-05SV 3P TCL-1SV3 HL (*1) Large TC-L Hle lock device HLN-05SV Terminal 4P TCL-1SV4 HL-S HLS-05SV cover Skeleton TTC 3P TTC-1SV3 Notes *1 HLF types are used for OFF lock HLN types for ON lock. Rear BTC 3P BTC-1SV3 *2 Specify the working voltage. Plug-in PTC 3P PTC-1SV3 Electrical operation device (*2) 50 60

107 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button f.5 50 Neutral pole 4 M screw f4.5 f.5 19 max. (Comb conductor 16.5 max.) (Conductor thickness t=4 max.) Conductor drilling for direct connection M40.7 taps or f5 Drilling plan 172 Rear connection Mounting plate t = 3.2 max Stud can be rotated 90 Mounting base 15 allowance Plug-in Plug-in terminal block Mounting plate M50. Terminal block mounting nut or screw mounted directly (Plug-in terminal block) max R M bolt M40.7 breaker mounting screw Insulation tube M40.7 taps 90 or f5 Drilling plan f mm clearance on each side of the hle frame Front-panel cutout M screw f.5 Conductor drilling Drilling plan f6 hole or M50. taps Other Details of terminal Remark: 1. 2-pole models are models with the central pole removed.

108 76 Low-voltage NF250-CV NF250-SV NF250-HV NF250-SV Model NF250-CV NF250-SV NF250-HV Rated current In (A) (*1) () (*1) () Number of poles Rated insulation voltage Ui (V) V / 10/ 500V 10/ 30/30 50/3 Rated 440V 15/12 36/36 65/65 short-circuit IEC AC 415V 25/19 36/36 / breaking (Icu/Ics) capacity 400V 25/19 36/36 75/75 (ka) 30V 25/19 36/36 75/75 230V 36/27 5/5 / DC (*1) 250V 15/12 20/20 (300V) 40/40 (300V) Stard attached parts (front connection) Mounting screw: M (2 3P: 2pcs, 4P: 4pcs) Insulation barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs) Note *1 Use two poles for three- four-pole products. In this case, do not use the neutral pole of the four-pole products. If wired as shown at the bottom of page 672, three-pole NF250-CV can be used for up to 400VDC, three-pole NF250-SV NF250-HV up to 500VDC four-pole products up to 600VDC. Operating 4h 4h 2h 1h 30min 20min 14min 10min 6min 4min Operating characteristics NF250-CV A-225A NF250-SV A-225A NF250-HV 125A-225A 2h 1h 30min 20min 14min 10min 6min 4min Operating characteristics NF250-CV 250A NF250-SV 250A NF250-HV 250A Operating time 2min 1min 30s 20s 10s 5s 2s Min. Max. Max. total breaking time Operating time 2min 1min 30s 20s 10s 5s 2s Min. Max. Max. total breaking time Other 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Internal Left-side mounting Operating hle AL Right-side mounting External % of rated current AC DC Time-delay trip Instantaneous trip AX SHT or UVT Lead-wire direction 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s AC DC Time-delay trip Instantaneous trip % of rated current Temperature Compensation Curve Current rating (%) (Rated ambient 0 temperature 40 C) Rated ambient temperature 40 Ambient temperature ( C) Type name Type name F F-2SV 2, 3P MI-05SV3 Operating hle V V-2SV Mechanical interlock MI 4P MI-2SV4 LC LC-05SV Small TC-S 2, 3P TCS-2SV3 HLF-05SV TCL-2SV3 Hle lock device HL (*1) 2, 3P HLN-05SV Large TC-L TCL-2SV3L HL-S HLS-2SV Terminal cover 4P TCL-2SV4 Notes *1 HLF types are used for OFF lock HLN types for ON lock. Skeleton TTC 2, 3P TTC-2SV3 *2 Specify the working voltage. Rear BTC 2, 3P BTC-2SV3 Plug-in PTC 2, 3P PTC-2SV3 Electrical operation device (*2) 50 60

109 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button Insulation barrier (removable) Neutral pole 102 M bolt (hex-socket) 50 f f4.5 C1 30 Solderless terminal for wire size A 14-95mm A -125mm 2 Wire connection f.5 Or f.5 C max max. (Conductor thickness t=7 max.) Conductor drilling for direct connection M40.7 taps or f5 Drilling plan 126 Rear connection Mounting plate t = 3.2 max. Mounting base Stud can be rotated allowance R f9 M bolt M40.7 breaker mounting screw Insulation tube 35 f M40.7 taps or f5 105 Drilling plan mm clearance on each side of the hle frame Front-panel cutout Plug-in Mounting plate Plug-in terminal block 11 6 M5 terminal block mounting screw allowance Insulation barrier f9 M bolt Stud attachable in this direction only (plug-in terminal block) Drilling plan f6 hole or M50. taps Other Remarks: 1. 2-pole models are models with the central pole removed. 2. Only 2-pole models are available for NF250-CV.

110 7 Low-voltage NF250-UV NF250-UV Model NF250-UV Rated current In (A) Number of poles Rated insulation voltage Ui (V) V 15/15 500V 200/ V 200/200 IEC AC 415V 200/200 (Icu/Ics) 400V 200/200 30V 200/ V 200/200 DC 250V Rated short-circuit breaking capacity (ka) Stard attached parts (front connection) Mounting screw: M (2 3P: 2pcs, 4P: 4pcs) Mounting screw: M (2 3P: 2pcs) Insulation barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs) Operating 4h 4h 2h 2h 1h 30min 20min 14min 10min 6min 4min Operating characteristics NF250-UV 125A-225A 1h 30min 20min 14min 10min 6min 4min Operating characteristics NF250-UV 250A Operating time 2min 1min 30s 20s 10s 5s 2s Min. Max. Operating time 2min 1min 30s 20s 10s 5s 2s Min. Max. Other 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Internal Left-side mounting Operating hle Time-delay trip Instantaneous trip AL Right-side mounting External AX % of rated current SHT or UVT EAL TBL TBM MG Max. total breaking time Lead-wire direction 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Max. total breaking time Time-delay trip Instantaneous trip % of rated current Temperature Compensation Curve Current rating (%) (Rated ambient 0 temperature 40 C) 10 0 Rated ambient temperature Ambient temperature ( C) Type name Type name F F-2UV 2, 3P MI-05SV3 Operating hle V V-2UV Mechanical interlock MI 4P MI-2SV4 LC LC-05SV Small TC-S 2, 3P TCS-2SV3 HLF-05SV TCL-2SV3 Hle lock device HL (*1) 2, 3P HLN-05SV Large TC-L TCL-2SV3L HL-S HLS-2SV Terminal cover 4P TCL-2SV4 Notes *1 HLF types are used for OFF lock HLN types for ON lock. Skeleton TTC 2, 3P TTC-2SV3 *2 Specify the working voltage. Rear BTC 2, 3P BTC-2SV3 Plug-in PTC 2, 3P PTC-2SV3 Electrical operation device (*2) 50 60

111 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button Insulation barrier (removable) Neutral pole f.5 M bolt (hex-socket) f4.5 f max. (Conductor thickness t=7 max.) Conductor drilling for direct connection Drilling plan 201 M40.7 taps or f5 Rear connection Mounting plate t = 3.2 max. Mounting base allowance Stud can be rotated R f9 M bolt M40.7 breaker mounting screw Insulation tube 35 f24 35 M40.7 taps or f5 Drilling plan mm clearance on each side of the hle frame Front-panel cutout Plug-in 265 Mounting plate Plug-in terminal block M5 terminal block mounting screw allowance Insulation barrier (Plug-in terminal block) f9 M bolt Stud attachable in this direction only f6 hole or M5 taps Other Drilling plan Remark: 1. 2-pole models are models with the central pole removed.

112 772 Low-voltage NF125-SGV NF250-SGV NF160-LGV NF125-HGV NF250-HGV NF250-RGV NF160-SGV NF125-LGV NF250-LGV NF160-HGV NF125-RGV NF250-SGV Model NF125-SGV NF160-SGV NF250-SGV NF125-LGV NF160-LGV NF250-LGV Rated current In (A) 16-20, 20-25, , 35-50, , -, , 20-25, , 35-50, , -, Number of poles Rated insulation voltage Ui (V) Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts (front connection) 690V / / / / / / 500V 30/30 30/30 30/30 36/36 36/36 36/36 440V 36/36 36/36 36/36 50/50 50/50 50/50 AC 415V 36/36 36/36 36/36 50/50 50/50 50/50 400V 36/36 36/36 36/36 50/50 50/50 50/50 30V 36/36 36/36 36/36 50/50 50/50 50/50 230V 5/5 5/5 5/5 90/90 90/90 90/90 200V 5/5 5/5 5/5 90/90 90/90 90/90 DC (*1) 300V 20/20 20/20 20/20 20/20 20/20 20/20 Mounting screw: M (2 3P: 2pcs, 4P: 4pcs) Insulation barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs) Model NF125-HGV NF160-HGV NF250-HGV NF125-RGV NF250-RGV Rated current In (A) 16-20, 20-25, , 35-50, , -, , 20-25, , 40-50, , 0-, Number of poles Rated insulation voltage Ui (V) Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts (front connection) 690V 10/ 10/ 10/ 500V 50/3 50/3 50/3 440V 65/65 65/65 65/65 125/ /125 AC 415V / / / 150/ / V 75/75 75/75 75/75 150/ /150 30V 75/75 75/75 75/75 150/ / V / / / 150/ / V / / / 150/ /150 DC (*1) 300V 40/40 40/40 40/40 Mounting screw: M (2 3P: 2pcs, 4P: 4pcs) Insulation barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs) Note *1 When wired as shown at the bottom of page 672, three-pole models can be used for up to 500VDC, four-pole models for up to 600VDC. Other Operating Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Min. Max. Operating Thermal-Adjustable types NF125-SGV NF125-LGV NF125-HGV NF125-RGV Current setting Ir = 16-20A(Rated current In=20A) Current setting Ir = 20-25A(Rated current In=25A) Current setting Ir = 25-32A(Rated current In=32A) AC lnstantaneous trip current AC DC 600A±120A 50A±1A DC Max. total breaking time Time-delay trip Instantaneous trip Current( % of Ir) Instantaneous tripping current( % of In) Internal Left-side mounting Operating hle AL Right-side mounting External AX Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s SHT or UVT Min. Operating Thermal-Adjustable types NF125-SGV NF125-LGV NF125-HGV Current setting Ir = 32-40A(Rated current In=40A) Current setting Ir = 35-50A(Rated current In=50A) NF125-RGV Current setting Ir = 32-40A(Rated current In=40A) Current setting Ir = 40-50A(Rated current In=50A) Max. AC lnstantaneous trip current AC DC 600A±120A 50A±1A DC Max. total breaking time Time-delay trip Instantaneous trip Current( % of Ir) Instantaneous tripping current( % of In) Lead-wire direction Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Min. NF125-SGV NF125-LGV NF125-HGV Current setting Ir = 40-63A(Rated current In= 63A) Current setting Ir = 45-63A(Rated current In= 63A) Current setting Ir = 56-0A(Rated current In= 0A) Current setting Ir = 63-A(Rated current In=A) NF125-RGV Current setting Ir = 50-63A(Rated current In= 63A) Current setting Ir = 63-0A(Rated current In= 0A) AC Max. Current( % of Ir) Operating Characteristic Curves Thermal-Adjustable types DC Instantaneous tripping current( % of In) lnstantaneous trip current ratio AC DC xln(%) xln(%) 0± ±260 Max. total breaking time Time-delay trip Instantaneous trip Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Min. Operating Characteristic Curves Thermal-Adjustable types NF125-SGV NF125-LGV NF125-HGV Current setting Ir = -A(Rated current In=A) Current setting Ir = 0-125A(Rated current In=125A) Current setting Ir = A(Rated current In=125A) NF160-SGV NF160-LGV NF160-HGV Current setting Ir = A(Rated current In=160A) NF250-SGV NF250-LGV NF250-HGV Current setting Ir = A(Rated current In=160A) Current setting Ir = A(Rated current In=200A) Current setting Ir = A(Rated current In=250A) Current setting Ir = A(Rated current In=250A) NF125-RGV Current setting Ir = 0-A(Rated current In=A) Current setting Ir = -125A(Rated current In=125A) NF250-RGV Current setting Ir = A(Rated current In=160A) Current setting Ir = A(Rated current In=200A) Current setting Ir = A(Rated current In=250A) Max. lnstantaneous trip current ratio AC DC xln(%) xln(%) 0± ±260 AC DC Max. total breaking time Time-delay trip Instantaneous trip Current( % of Ir) Instantaneous tripping current( % of In) Temperature Compensation Curve Current rating (%) Rated ambient temperature 40 Ambient temperature ( C) (rated ambient temperature 40 C) Type name Type name Operating hle F F-2SV 2, 3P MI-05SV3 Mechanical interlock MI V V-2SV 4P MI-2SV4 LC LC-05SV Small TC-S 2, 3P TCS-2SV3 Hle lock device HL (*1) HLF-05SV TCL-2SV3 2, 3P HLN-05SV Large TC-L TCL-2SV3L HL-S HLS-2SV Terminal cover 4P TCL-2SV4 Notes *1 HLF types are used for OFF lock HLN types for ON lock. Skeleton TTC 2, 3P TTC-2SV3 *2 Specify the working voltage. Rear BTC 2, 3P BTC-2SV3 Plug-in PTC 2, 3P PTC-2SV3 Electrical operation device (*2) 50 60

113 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button Insulating barrier (removable) Thermal Adj Button Rear connection Neutral pole 102 M bolt (hex-socket) 50 f f4.5 C1 30 Solderless terminal for wire size A 14-95mm A -125mm 2 Wire connection Or f.5 25 max. f.5 C max. (Conductor thickness t=7 max.) Conductor drilling for direct connection 35 M40.7 taps or f5 Drilling plan Mounting plate t max. = 3.2 Mounting base Stud can be rotated allowance R f9 M bolt 105 M40.7 breaker mounting screw Insulating tube 35 f24 M40.7 taps or f5 Drilling plan mm clearance on each side of the hle frame Front-panel cutout Plug-in Mounting plate Plug-in terminal block M5 terminal block mounting screw connection allowance 20 Insulating barrier f9 M bolt Stud attachable in this direction only 107 Drilling plan f6mm hole or M50. taps Other Remark: 1. 2-pole models are models with the central pole removed.

114 774 Low-voltage NF125-SEV NF125-HEV NF250-SEV NF250-HEV Model NF125-SEV NF125-HEV NF250-SEV NF250-HEV Rated current In (A) Current setting Ir (A) Number of poles Rated insulation voltage Ui (V) V / 10/ / 10/ 500V 30/30 50/3 30/30 50/3 Rated 440V 36/36 65/65 36/36 65/65 short-circuit IEC AC 415V 36/36 / 36/36 / breaking (Icu/Ics) capacity 400V 36/36 75/75 36/36 75/75 (ka) 30V 36/36 75/75 36/36 75/75 230V 5/5 / 5/5 / DC 250V Stard attached parts (front connection) Mounting screw: M (3P: 2pcs, 4P: 4pcs) Insulation barrier: (3P: 4pcs, 4P: 6pcs) NF125-SEV Other Operating Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s I 6 t ON I 6 t OFF I 2 t ON Internal Left-side mounting Operating hle LTD operating time at 125% (I 6 t ON) 6s (TL = s set) 540s (TL = 0s set) 400s (TL = 60s set) 0s (TL = 12s set) Operating characteristics NF125-SEV NF125-HEV Current setting Ir LTD operating time TL 12600s ±20% (at 200%) Rated current In 32A 63A 125A STD pickup current Is Ir ( ) ±15% STD operating time Ts 0.3±0.06s 0.2±0.04s 0.1±0.03s I 2 t OFF INST pickup current Ii In 2-14 ±15%, Ir 14 ±15% Max. total breaking time AL Right-side mounting External % of current setting Ir Instantaneous tripping current (% of rated current or % of current setting Ir) AX SHT or UVT PAL (Note) Lead-wire direction Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s I 6 t ON I 6 t OFF I 2 t ON I 2 t OFF LTD operating time at 125% (I 6 t ON) 6s (TL = s set) 540s (TL = 0s set) 400s (TL = 60s set) 0s (TL = 12s set) INST pickup current Ii In 2-14 ±15%, Ir 14 ±15% Operating characteristics NF250-SEV NF250-HEV Current setting Ir Rated current In 160A 250A LTD operating time TL 12600s ±20% (at 200%) STD pickup current Is Ir ( ) ±15% STD operating time Ts 0.3±0.06s 0.2±0.04s 0.1±0.03s Max. total breaking time % of current setting Ir Instantaneous tripping current (% of rated current or % of current setting Ir) Current Reducing Curve Derating of load current (%) Rated ambient temperature Ambient temperature ( C) 60 The rated current does not have thermal characteristics. Reduce the current as shown in the curve on the left chart if the ambient temperature exceeds 40 C. Type name Type name Operating hle F F-2SV 3P MI-05SV3 Mechanical interlock MI V V-2SV 4P MI-2SV4 LC LC-05SV Small TC-S 3P TCS-2SV3 Hle lock device HL (*1) HLF-05SV TCL-2SV3 3P HLN-05SV Large TC-L TCL-2SV3L HL-S HLS-2SV Terminal cover 4P TCL-2SV4 Notes *1 HLF types are used for OFF lock HLN types for ON lock. Skeleton TTC 3P TTC-2SV3 *2 Specify the working voltage. Rear BTC 3P BTC-2SV3 Plug-in PTC 3P PTC-2SV3 Electrical operation device (*2)

115 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button Trip characteristics selector Rear connection Insulation barrier (removable) Neutral pole 102 M bolt (hex-socket) 50 f f4.5 C1 30 Solderless terminal for wire size A 14-95mm A -125mm 2 Wire connection f.5 C max. Or f max. (Conductor thickness t=7 max.) Conductor drilling for direct connection M40.7 taps or f5 Drilling plan Mounting plate t=3.2 max. Mounting base Stud can be rotated connection allowance R f9 M bolt M40.7 breaker mounting screw Insulation tube 35 f24 M40.7 taps or f5 Drilling plan mm clearance on each side of the hle frame Front-panel cutout Plug-in Mounting plate Plug-in terminal block M5 terminal block mounting screw connection allowance Insulation barrier f9 M bolt Stud attachable in this direction only f6 hole or M50. taps Other Drilling plan

116 776 Low-voltage NF400-CW NF400-SW NF400-SW Operating Model NF400-CW NF400-SW Rated current In (A) Number of poles Rated insulation voltage Ui (V) Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts AC 690V 10/10 500V 15/ 30/30 440V 25/13 42/42 400V 36/1 45/45 230V 50/25 5/5 DC (*1) 250V 20/10 40/40 Front connection Mounting screw: M6 60 (4pcs) Insulating barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs) Rear Mounting screw: M6 72 (4pcs) connection Note *1 When wired as shown at the bottom of page 672, models can be used for up to 400VDC, models for up to 500VDC. 4h 4h Other Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 125 Min. Time delay trip Internal Left-side mounting Operating hle Right-side AL mounting AC % of rated current Operating characteristics NF400-CW Max. DC Max. total interrupting time Instantaneous trip AX SHT or UVT (*1) (*1) (*1) (*1) Lead wire direction Note *1 Right-side mounting is stard of SHT UVT. Specify separately for left-side mounting. External Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 125 Min. Time delay trip Max. Instantaneous trip % of rated current Operating characteristics NF400-SW AC DC Max.total interrupting time Temperature Compensation Curve Current rating (%) Rated ambient temperature Ambient temperature ( C) Type name Type name Operating hle F F-4S 2, 3P TCL-4SW3 Large TC-L V V-4S 4P TCL-4SW4 Mechanical interlock MI 2, 3P MI-4SW3 Terminal 2, 3P TTC-4SW3 Skeleton TTC 4P MI-4SW4 cover 4P TTC-4SW4 Auxiliary hle HT HT-4CW, HT-4SW 2, 3P BTC-4SW3 Rear BTC Note *1 Specify the operation method voltage. Order in combination with the breaker 4P BTC-4SW4 unit. HL HL-4CW, HL-4SW Hle lock device HL-S HLS-4SW 3P Electrical operation device NFM 4P (*1)

117 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection 110 Mounting hole Trip button Insulating barrier (removable) f14 M12 bolt Conductor thickness t= max Neutral pole f12.5 f (NF400-SW) 134 (NF400-CW) f10.5 Conductor thickness t= max. Conductor drilling for direct connection 44 M6 tap or f7 44 Drilling plan 194 R mm clearance on each side of the hle frame. Front-panel cutout Rear connection Boring dimensions for rear connection type barriers () Stud can be rotated 90 Mounting plate allowance M6 tap or f7 Groove for reducing heat by overcurrent Line side 6-f M6 tap or f f13 M12 bolt M6 screw for mounting breaker Insulation tube 44 f Drilling plan Load side M4 screw Add these tapped holes in positions to stard boring. Plug-in Note The bore dimensional drawing shows the breaker viewed from the rear. 20 Plug-in terminal block Mounting plate M terminal block mounting screw allowance f13 M12 bolt Stud attachable in this direction only Insulating barrier f Drilling plan Other Remark: 1. 2-pole models are models with the central pole removed.

118 77 Low-voltage NF400-SEW NF400-HEW NF400-REW NF400-SEW Model NF400-SEW NF400-HEW NF400-REW Rated current In (A) adjustable Number of poles Rated insulation voltage Ui (V) Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts AC 690V 10/10 35/1 500V 30/30 50/50 /35 440V 42/42 65/65 125/63 400V 50/50 / 125/63 230V 5/5 / 150/75 Front connection Rear connection Mounting screw: M6 72 (4pcs) Insulating barrier: (3P: 4pcs, 4P: 6pcs) Mounting screw: M6 5 (4pcs) Operating Internal Other Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip Ir x( ±10% ) Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) LTD operating time at 125% 0s(TL=150s set) 6s(TL=s set) 400s(TL= 60s set) 0s(TL= 12s set) Current setting Ir: A (Adjustable) INST pickup current II x4-x16 ±15% (Magnification to In) Operating characteristics NF400-SEW NF400-HEW NF400-REW Rated Current In: 400A LTD operating time TL s ±20% (at 200%) STD pickup current Is Ir x( ) ±15% STD operating time Ts 0.3 ± 0.06s 0.2 ± 0.04s 0.1 ± 0.03s 0.06 ± 0.02s Max. total breaking time Current (% of Ir) Instantaneous tripping current (% of In) External Left-side mounting Operating hle Right-side Lead wire AL AX SHT or UVT PAL mounting direction (*1) (*1) (*1) (*1) Note *1 Right-side mounting is stard of SHT UVT. Specify separately for left-side mounting. Current Reducing Curve Continuous load current (%) Rated ambient temperature Ambient temperature ( C) Type name Type name Operating hle F F-4S 3P TCL-4SW3 (*2) Large TC-L V V-4S 4P TCL-4SW4 (*3) Mechanical interlock MI 3P MI-4SW3 Terminal 3P TTC-4SW3 Skeleton TTC 4P MI-4SW4 cover 4P TTC-4SW4 Auxiliary hle HT HT-4SW 3P BTC-4SW3 (*2) Rear BTC Notes *1 Specify the operation method voltage. Order in combination with the 4P BTC-4SW4 (*3) breaker unit. HL HL-4SW *2 This is for NF400-SEW. For rear terminal cover of NF400-HEW/REW, use Hle lock device PTC-4SW3. HL-S HLS-4SW *3 This is for NF400-SEW/HEW. 3P Electrical operation device NFM 4P (*1)

119 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection 110 Mounting hole Trip button Insulating barrier (removable) f14 M12 bolt Conductor thickness t= max Neutral pole f12.5 f f10.5 Conductor thickness t= max. Conductor drilling for direct connection 44 M6 tap or f7 44 Drilling plan 194 R mm clearance on each side of the hle frame. Front-panel cutout Rear connection Boring dimensions for rear connection type barriers () Mounting plate allowance Stud can be rotated 90 M6 tap or f7 Groove for reducing heat by overcurrent Line side 6-f M6 tap or f f13 M12 bolt M6 screw for mounting breaker Insulation tube 44 7 f Drilling plan Load side M4 screw Add these tapped holes in positions to stard boring. Plug-in 20 Plug-in terminal block Mounting plate M terminal block mounting screw allowance f13 M12 bolt Stud attachable in this direction only Insulating barrier f Note The bore dimensional drawing shows the breaker viewed from the rear Drilling plan Other

120 70 Low-voltage NF400-UEW NF400-UEW Operating Model Rated current In (A) Internal NF400-UEW adjustable Number of poles 3 4 Rated insulation voltage Ui (V) 690 Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) AC Stard attached parts ( models are provided with auxiliary hle.) 690V 500V 1/1 440V 200/ V 200/ V 200/200 Front connection Rear connection Mounting screw: M6 65 (2pcs), M6 174 (2pcs) Insulating barrier: (3P: 4pcs) Mounting screw: M6 72 (2pcs), M6 11 (2pcs) 10h 5h 2h Operating characteristics NF400-UEW Left-side mounting Operating hle Right-side Lead wire AL AX SHT or UVT PAL mounting direction Other Operating time 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip Ir x( ±10% ) Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) LTD operating time at 125% 0s(TL=150s set) 6s(TL=s set) 400s(TL= 60s set) 0s(TL= 12s set) Current setting Ir: A (Adjustable) INST pickup current II x4-x16 ±15% (Magnification to In) Current (% of Ir) Instantaneous tripping current (% of In) External Rated Current In: 400A LTD operating time TL s ±20% (at 200%) STD pickup current Is Ir x( ) ±15% STD operating time Ts 0.3 ± 0.06s 0.2 ± 0.04s 0.1 ± 0.03s 0.06 ± 0.02s Max. total breaking time (*1) (*1) (*1) (*1) Note *1 Right-side mounting is stard of SHT UVT. Specify separately for left-side mounting. Remarks: 1. Specification of model is same as that of NF00-UEW. Current Reducing Curve Continuous load current (%) Rated ambient temperature Ambient temperature ( C) Type name Type name F F-4U Large TC-L 3P TCL-4SW3 Operating hle Terminal V V-4U Skeleton TTC 3P cover Mechanical interlock MI MI-4SW3 Rear BTC 3P BTC-4SW3 Auxiliary hle HT HT-4SW HL HL-4SW Hle lock device Note *1 Specify the operation method voltage. Order in combination with the breaker HL-S HLS-4UW unit. Electrical operation device (*1) Remark *1 Specification of model is same as that of NF00-UEW.

121 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection 110 Mounting hole Trip button 51 2 Insulating barrier (removable) f14 M12 bolt Conductor thickness t= max f12.5 f f7 f f10.5 Conductor thickness t= max. Conductor drilling for direct connection M6 tap or f7 Drilling plan R mm clearance on each side of the hle frame. 92 Front-panel cutout Rear connection Boring dimensions for rear connection type barriers () Plug-in Mounting plate allowance Stud can be rotated f13 M12 bolt Plug-in terminal block 12 3 Mounting angle M terminal block mounting screw Insulation tube 160 M6 screw or f7 M6 screw for mounting breaker allowance f35 Drilling plan Groove for reducing heat by overcurrent Stud attachable in this direction only f10 44 Line side Load side f35 max M6 tap or f7 Note The bore dimensional drawing shows the breaker viewed from the rear. Mounting angle -M4 screw Add these tapped holes in positions to stard boring. 21 f13 M12 bolt 7 Insulating barrier Drilling plan Other

122 72 Low-voltage NF630-CW NF630-SW NF630-SW Operating Model NF630-CW NF630-SW Rated current In (A) Number of poles Rated insulation voltage Ui (V) Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts AC 690V 10/10 500V 1/9 30/30 440V 36/1 42/42 400V 36/1 50/50 230V 50/25 5/5 DC (*1) 250V 20/10 40/40 Front connection Mounting screw: M6 72 (4pcs) Insulating barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs) Rear Mounting screw: M6 5 (4pcs) connection Note *1 When wired as shown at the bottom of page 672, models can be used for up to 400VDC, models for up to 500VDC. 4h 2h 1h 30min Operating characteristics NF630-CW 4h 2h 1h 30min Operating characteristics NF630-SW 20min 14min 10min 6min 4min 2min 20min 14min 10min 6min 4min 2min Operating time 1min 30s 20s 10s 5s 2s Min. Max. Operating time 1min 30s 20s 10s 5s 2s Min. Max. Other 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 125 Time delay trip Internal Left-side mounting Operating hle Right-side AL mounting AC % of rated current DC Max.total interrupting time Instantaneous trip AX SHT or UVT (*1) (*1) (*1) (*1) Lead wire direction Note *1 Right-side mounting is stard of SHT UVT. Specify separately for left-side mounting. External 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 125 Time delay trip % of rated current AC DC Max.total interrupting time Instantaneous trip Temperature Compensation Curve Current rating (%) Rated ambient temperature Ambient temperature ( C) Type name Type name Operating hle F F-4S 2, 3P TCL-4SW3 Large TC-L V V-4S 4P TCL-4SW4 Mechanical interlock MI 2, 3P MI-4SW3 Terminal 2, 3P TTC-4SW3 Skeleton TTC 4P MI-4SW4 cover 4P TTC-4SW4 Auxiliary hle HT HT-4SW 2, 3P BTC-4SW3 Rear BTC Note *1 Specify the operation method voltage. Order in combination with the breaker 4P BTC-4SW4 unit. HL HL-4SW Hle lock device HL-S HLS-4SW 3P Electrical operation device NFM 4P (*1)

123 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection 110 Mounting hole Trip button LC LC Insulating barrier (removable) f14 M12 bolt LC Neutral pole Conductor thickness t=10 max f12.5 f f10.5 Conductor thickness t=10 max. 12 Conductor drilling for direct connection LC LC 44 M6 screw or f7 Drilling plan 44 L C 194 LC R6 LC mm clearance on each side of hle. Front-plate cutout 92 LC Rear connection 113 Mounting plate allowance f13 M12 bolt Stud can be rotated Insulating tube attached to 3P:Center pole 4P:Center neutral poles M6 screw or f7 LC M6 breaker mounting screw LC 44 7 Eddy-current heat-reducing slit f35 44 LC Boring dimensions for rear connection type barriers () Line side Load side f M6 tap or f7 -M4 screw Add these tapped holes in positions to stard boring. 20 Plug-in Plug-in terminal block LC Mounting plate 25 M terminal block mounting screw allowance LC Drilling plan LC LC Note The bore dimensional drawing shows the breaker viewed from the rear. LC Stud attachable in this direction only f f13 M12 bolt Insulating barrier Drilling plan Other Remark: 1. 2-pole models are models with the central pole removed.

124 74 Low-voltage NF630-SEW NF630-HEW NF630-REW NF630-SEW Model NF630-SEW NF630-HEW NF630-REW Rated current In (A) adjustable Number of poles Rated insulation voltage Ui (V) Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts AC 690V 10/10 35/1 500V 30/30 50/50 /35 440V 42/42 65/65 125/63 400V 50/50 / 125/63 230V 5/5 / 150/75 Front connection Rear connection Mounting screw: M6 72 (4pcs) Insulating barrier: (3P: 4pcs, 4P: 6pcs) Mounting screw: M6 5 (4pcs) Other Operating Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip Ir x( ±10% ) Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) LTD operating time at 125% 0s(TL=150s set) 6s(TL=s set) 400s(TL= 60s set) 0s(TL= 12s set) INST pickup current II x4-x15 ±15% (Magnification to In) Operating characteristics NF630-SEW NF630-HEW NF630-REW Current setting Rated Current Ir: A In: 630A (Adjustable) LTD operating time TL s ±20% (at 200%) STD pickup current Is Ir x( ) ±15% STD operating time Ts 0.3 ± 0.06s 0.2 ± 0.04s 0.1 ± 0.03s 0.06 ± 0.02s Max. total breaking time Current (% of Ir) Instantaneous tripping current (% of In) External Operating hle Internal Left-side mounting Operating hle Right-side Lead wire AL AX SHT or UVT PAL mounting direction (*1) (*1) (*1) (*1) Note *1 Right-side mounting is stard of SHT UVT. Specify separately for left-side mounting. Current Reducing Curve Continuous load current (%) Rated ambient temperature Ambient temperature ( C) Type name Type name F F-4S 3P TCL-4SW3 (*2) Large TC-L V V-4S 4P TCL-4SW4 (*3) 3P MI-4SW3 Mechanical interlock Terminal 3P TTC-4SW3 MI Skeleton TTC 4P MI-4SW4 cover 4P TTC-4SW4 Auxiliary hle HT HT-4SW 3P BTC-4SW3 (*2) Rear BTC Notes *1 Specify the operation method voltage. Order in combination with the 4P BTC-4SW4 (*3) breaker unit. HL HL-4SW *2 This is for NF630-SEW. For rear terminal cover of NF630-HEW/REW, use Hle lock device PTC-4SW3. HL-S HLS-4SW *3 This is for NF630-SEW/HEW. 3P Electrical operation device NFM (*1) 4P

125 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection 110 Mounting hole Trip button LC LC Insulating barrier (removable) f14 M12 bolt LC Neutral pole Conductor thickness t=10 max f12.5 f f10.5 Conductor thickness t=10 max. Conductor drilling for direct connection LC LC M6 screw or f7 Drilling plan 44 L C 194 LC R6 LC mm clearance on each side of hle. Front-plate cutout 92 LC Rear connection 113 Mounting plate allowance f13 M12 bolt Stud can be rotated M6 breaker mounting screw Insulating tube attached to 3P:Center pole 4P:Center neutral poles M6 screw or f7 LC LC 44 7 Eddy-current heat-reducing slit f35 44 LC Boring dimensions for rear connection type barriers () Line side Load side f M6 tap or f7 -M4 screw Add these tapped holes in positions to stard boring. 20 Plug-in Plug-in terminal block LC Mounting plate 25 M terminal block mounting screw allowance LC Drilling plan LC LC Note The bore dimensional drawing shows the breaker viewed from the rear. LC Stud attachable in this direction only f f13 M12 bolt Insulating barrier Drilling plan Other

126 76 Low-voltage NF00-CEW NF00-SEW NF00-HEW NF00-REW Model NF00-CEW NF00-SEW NF00-HEW NF00-REW Rated current In (A) adjustable Number of poles Rated insulation voltage Ui (V) Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) AC Stard attached parts ( models are provided with auxiliary hle.) 690V 10/10 15/15 500V 1/9 30/30 50/50 /35 440V 36/1 42/42 65/65 125/63 400V 36/1 50/50 / 125/63 230V 50/25 5/5 / 150/75 Front connection Rear connection Mounting screw: M6 35 (4pcs) Insulating barrier: (3P: 2pcs, 4P: 3pcs) Mounting screw: M6 40 (4pcs) Other Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip Ir x( ±10% ) Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) NF00-SEW Operating LTD operating time at 125% 0s(TL=150s set) 6s(TL=s set) 400s(TL= 60s set) 0s(TL= 12s set) INST pickup current II x4-x12 ±15% (Magnification to In) Operating characteristics NF00-CEW NF00-SEW NF00-HEW NF00-REW Current setting Ir: A (Adjustable) Rated Current In: 00A LTD operating time TL s ±20% (at 200%) STD pickup current Is Ir x( ) ±15% STD operating time Ts 0.3 ± 0.06s 0.2 ± 0.04s 0.1 ± 0.03s 0.06 ± 0.02s Max. total breaking time Current (% of Ir) Instantaneous tripping current (% of In) External Operating hle Internal Left-side mounting (*1) Operating hle Right-side Lead wire AL AX SHT or UVT PAL mounting direction (*1) (*1) Note *1 Right-side mounting is stard of SHT UVT. Specify separately for left-side mounting. Current Reducing Curve Working current correcting ratio (%) Rated ambient temperature Ambient temperature ( C) Type name Type name F F-S 3P TCL-SW3 Large TC-L V V-S 4P TCL-SW4 3P MI-SW3 Mechanical interlock Terminal 3P TTC-SW3 MI Skeleton TTC 4P MI-SW4 cover 4P TTC-SW4 Auxiliary hle HT HT-4SW 3P BTC-SW3 Rear BTC Note *1 Specify the operation method voltage. Order in combination with the breaker 4P BTC-SW4 unit. HL HL-4SW Hle lock device HL-S HLS-SW Electrical operation device NFM 3P 4P (*1) (*1)

127 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Insulating barrier (removable) Trip button N Neutral pole f14 M12 bolt Conductor thickness t=12 max. Auxiliary hle (removable) 102 f f f Terminal dimension for directly connecting conductor 12 (Conductor thickness t=10 max.) Conductor drilling for direct connection M6 tap or f7 Drilling plan 243 R mm clearance on each side of the hle frame. Front-panel cutout Rear connection Boring dimensions for rear connection type barriers () allowance 25 Mounting plate Stud can be rotated f13 M12 bolt M6 tap or f7 M6 screw for mounting breaker 140 Groove for reducing heat by overcurrent f4 Drilling plan f M6 tap or f7 -M4 screw Add these tapped holes in positions to stard boring. Plug-in Plug-in terminal block 20 Mounting plate Stud can be rotated allowance M terminal block mounting screw f13 M12 bolt f10 Drilling plan Other

128 7 Low-voltage NF00-SDW NF00-SDW Operating 4h 2h Operating characteristics 1h NF00-SDW Model Internal Left-side mounting Operating hle Right-side AL mounting AX SHT or UVT NF00-SDW Rated current In (A) (0), 00 Number of poles 2 Rated insulation voltage Ui (V) 690 Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Time constant not larger than 10ms Stard attached parts ( models are provided with auxiliary hle.) DC 250V 40/40 Front connection Rear connection Mounting screw: M6 35 (4pcs) Insulating barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs) Mounting screw: M6 40 (4pcs) Lead wire direction Other Operating time 30min 20min 14min 10min 6min 4min 2min 1min. 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 125 Min. Time-delay trip Adjustment range 0A Adjustment range 00A Max. Inst trip % of rated current External 0A,00A DC Inst. trip adjustment range (4 steps) Control setting Lo 2 3 Hi Inst trip current (A) 2600± ± ± ±1300 Max. total interrupting time (*1) (*1) (*1) Note *1 Right-side mounting is stard of SHT UVT. Specify separately for left-side mounting. Temperature Compensation Curve Current rating (%) Rated ambient temperature (*1) Ambient temperature ( C) Type name Type name Operating hle F F-S 2, 3P TCL-SW3 Large TC-L V V-S 4P TCL-SW4 Mechanical interlock MI 2, 3P MI-SW3 Terminal 2, 3P TTC-SW3 Skeleton TTC 4P MI-SW4 cover 4P TTC-SW4 Auxiliary hle HT HT-4SW 2, 3P BTC-SW3 Rear BTC Note *1 Specify the operation method voltage. Order in combination with the breaker 4P BTC-SW4 unit. HL HL-4SW Hle lock device HL-S HLS-SW 2, 3P Electrical operation device NFM 4P (*1)

129 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Insulating barrier (removable) Trip button N f14 Neutral pole f14 M12 bolt Conductor thickness t=12 max. Auxiliary hle (removable) f f Terminal dimension for directly connecting conductor (Conductor thickness t=10 max.) Conductor drilling for direct connection M6 tap or f7 Drilling plan 243 R mm clearance on each side of the hle frame. Front-panel cutout 92 Rear connection Boring dimensions for rear connection type barriers () allowance 25 Mounting plate Stud can be rotated 90 M6 tap or f7 Groove for reducing heat by overcurrent f M6 tap or f f13 M12 bolt M6 screw for mounting breaker 140 f4 Drilling plan M4 screw Add these tapped holes in positions to stard boring. Plug-in Mounting plate Stud can be rotated 90 Plug-in terminal block allowance 25 M terminal block mounting screw f13 M12 bolt f10 Drilling plan Other Remarks: 1. Stard specification of NF00-SDW is 2-pole model. models are available for DC special voltage pole models are models with the central pole removed.

130 790 Low-voltage NF00-UEW NF00-UEW Operating Model Rated current In (A) Internal NF00-UEW adjustable Number of poles 3 4 Rated insulation voltage Ui (V) 690 Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) AC Stard attached parts ( models are provided with auxiliary hle.) 690V 35/35 500V 1/1 440V 200/ V 200/ V 200/200 Mounting screw: 3P: M6 35, M6 132 (2pcs each) Front 4P: M6 35 (3pcs), M6 132 (2pcs) connection Insulating barrier: (3P: 2pcs, 4P: 3pcs) Rear Mounting screw: 3P: M6 40, M6 137 (2pcs each) connection 4P: M6 40 (3pcs), M6 137 (2pcs) 10h 5h Operating characteristics Left-side mounting Operating hle Right-side Lead wire AL AX SHT or UVT PAL mounting direction 2h NF00-UEW Other Operating time 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip Ir x( ±10% ) Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) LTD operating time at-125% 0s(TL=150s set) 6s(TL=s set) 400s(TL= 60s set) 0s(TL= 12s set) INST pickup current II x4-x12 ±15% (Magnification to In) Current setting Ir: A (Adjustable) Rated Current In: 00A LTD operating time TL s ±20% (at 200%) STD pickup current Is Ir x( ) ±15% STD operating time Ts 0.3 ± 0.06s 0.2 ± 0.04s 0.1 ± 0.03s 0.06 ± 0.02s Max. total breaking time Current (% of Ir) Instantaneous tripping current (% of In) External Operating hle Mechanical interlock (*1) (*1) (*1) Note *1 Right-side mounting is stard of SHT UVT. Specify separately for left-side mounting. Current Reducing Curve Continuous load current (%) Rated ambient temperature (*1) Ambient temperature ( C) Type name Type name F F-U 3P TCL-UW3 Large TC-L V 4P TCL-UW4 MI Auxiliary hle HT HT-4SW Note *1 Specify the operation method voltage. Order in combination with the breaker unit. 3P MI-SW3 Terminal 3P Skeleton TTC 4P MI-SW4 cover 4P Rear Hle lock device BTC HL HL-S 3P 4P BTC-SW3 BTC-SW4 HL-4SW Electrical operation device (*1) HLS-UW

131 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing 110 Trip button Front connection Mounting hole Rear connection 13 Insulating barrier (removable) 14 M6 screw or f7 Drilling plan N f M12 bolt Neutral pole f14 M12 bolt Conductor thickness t=12 max. 275 Trip button Auxiliary hle (removable) 102 f Mounting hole Insulating barrier (removable) 35 NF400-UEW Stard direction of stud is horizontal M6 tap or f7 Groove for reducing on power side, vertical on load side. heat by overcurrent Mounting plate allowance Otherwise, specify the direction. 25 M6 screw for mounting breaker 140 f4 Drilling plan N f f7 f Neutral pole f14 M12 bolt Auxiliary hle (removable) f14 f Mounting plate 44 (ON side) (OFF side) Terminal dimension for directly connecting conductor (Conductor thickness t=10 max.) Conductor drilling for direct connection Conductor thickness t= max f14 f7 allowance 26 f Stud can be rotated f13 M12 bolt NF400-UEW 5 10 R mm clearance on each side of the hle frame. Front-panel cutout f Boring dimensions for rear connection type barriers () 4-M6 tap or f7 -M4 screw Add these tapped holes in positions to stard boring. Other

132 792 Low-voltage NF0-SEW NF1250-SEW NF1250-SEW Operating Model NF0-SEW NF1250-SEW Rated current In (A) 5000 Adjustable Adjustable Number of poles Rated insulation voltage Ui (V) Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts AC 690V 25/13 25/13 500V 65/33 65/33 440V 5/43 5/43 400V 5/43 5/43 230V 125/63 125/63 Front connection Rear connection Mounting screw: M 40 (4pcs) Insulating barrier: (3P: 2pcs, 4P: 3pcs) Auxiliary hle: (1pc) Mounting screw: M 40 (4pcs) Insulating barrier: (3P: 2pcs, 4P: 4pcs) Auxiliary hle: (1pc) 10h 10h Operating time 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s Pre-alarm pickup current Ip In x( ) ±10% LTD operating time at-125% 0s(TL=150s set) 6s(TL=s set) 400s(TL= 60s set) 0s(TL= 12s set) Operating characteristics NF0-SEW Current setting Rated Current Ir:500-0A In:0A (Adjustable) LTD operating time TL s ±20% (at 200%) STD pickup current Is In x( ) ±15% Operating time 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s Pre-alarm pickup current Ip In x( ) ±10% LTD operating time at-125% 0s(TL=150s set) 6s(TL=s set) 400s(TL= 60s set) 0s(TL= 12s set) Operating characteristics NF1250-SEW Current setting Rated Current Ir: A In:1250A (Adjustable) LTD operating time TL s ±20% (at 200%) STD pickup current Is In x( ) ±15% Other 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm Pre-alarm STD operating time Ts 0.5s operating time Tp operating time Tp 0.3 ± 0.06s TL TL 0.2 ± 0.04s ±20% Tp= ±20% 0.2s Tp= 2 2 (at 200%) (at 200%) 0.1 ± 0.03s 0.1s 0.06 ± 0.02s 0.05s INST pickup current II INST pickup current II x (4-x12) ±15% 0.02s x (4-x12) ±15% (Magnification to In) Max. total (Magnification to In) breaking time 0.01s Internal Left-side mounting Current (% of Ir) Instantaneous tripping current (% of In) Operating hle Right-side AL mounting External AX SHT or UVT Lead wire direction PAL 1s Current (% of Ir) Instantaneous tripping current (% of In) Current Reducing Curve Continuous load current (%) Rated ambient temperature Ambient temperature ( C) STD operating time Ts 0.3 ± 0.06s 0.2 ± 0.04s (An order for should be placed at the same time as an order of circuit breaker main body.) Type name Type name Operating hle F 3P F10SW Auxiliary hle HT HT-10SW 4P F10SW4P Hle lock device HL HL () Mechanical interlock MI 3P MI-10SW3 3P TCL-10SW3 Large terminal cover TC-L 4P MI-10SW4 4P TCL-10SW4 Note *1 Specify the operation method voltage. Order in combination with the breaker 3P Electrical operation device unit. NFM 4P (*1) 0.1 ± 0.03s 0.06 ± 0.02s Max. total breaking time

133 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection f13 M12 bolt Rear connection Insulating barrier (removable) Mounting hole 0 Mounting plate M screw for mounting breaker Stud can be rotated Neutral pole Conductor thickness t=2pcs max. 346 Bolt M1250 Auxiliary hle (removable) f f M tap or f10 Drilling plan allowance f Conductor thickness t=62pcs max. Bolt M1245 Insulation cover (removable) mm clearance on each M tap or f10 side of the hle frame. Front-panel cutout Drilling plan R Plug-in 225 Plug-in terminal block Mounting plate M10 terminal block mounting screw Stud can be rotated 90 Conductor thickness t=62pcs max. Bolt M allowance f13 Insulating barrier f Drilling plan Other

134 794 Low-voltage NF1250-SDW NF1250-SDW Operating Model NF1250-SDW Rated current In (Amp.) 0, 1250 Number of poles 2 Rated insulation voltage Ui (V) 690 Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Time constant not large than 10ms Stard Attached parts DC 250V 40/20 Front connection Rear connection Mounting screw: M 40 (4pcs) Insulating barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs) Auxiliary hle: (1pc) Mounting screw: M 40 (4pcs) Insulating barrier: (3P: 2pcs, 4P: 4pcs) Auxiliary hle: (1pc) Other Operating time 3h 2h 1h 40min 20min 10min 6min 4min 2min 1min 40s 30s 20s 10s 6s 4s 2s 1s 0.6s 0.4s 0.2s 0.1s Max. total breaking time 0.06s 0.04s Time-delay 0.02s trip Instantaneous trip 0.01s Current (% of rated current) Internal Left-side mounting Min. Operating hle Right-side mounting Max. AL EAL AX TBL External SHT or UVT TBM Operating characteristics NF1250-SDW 0A Adjustable range of stard instantaneous tripping current (4 stages) Position of adjusting knob L0 2 3 Hi PAL Stard value of instantaneous tripping current (A) 200±0 4200±0 5600±0 00±0 MG ATU Lead wire direction Operating time 3h 2h 1h 40min 20min 10min 6min 4min 2min 1min 40s 30s 20s 10s 6s 4s 2s 1s 0.6s 0.4s 0.2s 0.1s Max. total breaking time 0.06s 0.04s Time-delay 0.02s trip Instantaneous trip 0.01s Current (% of rated current) Temperature Compensation Curve Continuous load current (%) A, 1250A 90 Min A Max. Operating characteristics NF1250-SDW 1250A Adjustable range of stard instantaneous tripping current (4 stages) Position of adjusting knob L0 2 3 Hi Rated ambient temperature Ambient temperature ( C) Stard value of instantaneous tripping current (A) 200±0 4200±0 5600±0 00±0 (An order for should be placed at the same time as an order of circuit breaker main body.) Type name Type name Operating hle F 2, 3P F10SW Auxiliary hle HT HT-10SW 4P F10SW4P Hle lock device HL HL () Mechanical interlock MI 2, 3P MI-10SW3 2, 3P TCL-10SW3 Large terminal cover TC-L 4P MI-10SW4 4P TCL-10SW4 Note *1 Specify the operation method voltage. Order in combination with the breaker 2, 3P Electrical operation device unit. NFM 4P (*1) 60

135 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Rear connection Trip button f13 M12 bolt Plug-in allowance 22 f Same dimensions as NF0-SEW NF1250-SEW Insulation barrier (removable) 0 Mounting plate M screw for breaker mounting Stud can be turned Conductor thickness t=62 pcs. max. 406 Conductor thickness t=2 pcs. max. Bolt M Auxiliary hle (removable) f17.5 f Differing in external dimensions from NF0-SEW NF1250-SEW. 12 Bolt M Insulation cover (removable) M screw or f10 1.0mm clearance on each side of the hle frame Drilling plan Front-panel cutout Plug-in terminal block Mounting plate M10terminal block mounting screw Stud can be turned Mounting hole Differing in external dimensions from NF0-SEW NF1250-SEW. allowance Conductor thickness 43 t=62 pcs. max. f Bolt M1245 Insulation barrier M screw or f Drilling plan Drilling plan Remarks: 1. Stard specification of NF1250-SDW is 2-pole model. models are available for DC special voltage pole models are models with the central pole removed. R f Other

136 796 Low-voltage NF1600-SEW NF1600-SEW Operating Model NF1600-SEW Rated current In (A) Adjustable Number of poles 3 4 Rated insulation voltage Ui (V) 690 Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts AC 690V 25/13 500V 65/33 440V 5/43 400V 5/43 230V 125/63 Front connection Rear connection Internal Mounting screw: M 40 (4pcs) Insulating barrier: (3P: 2pcs, 4P: 3pcs) Auxiliary hle: (1pc) Mounting screw: M 40 (4pcs) Auxiliary hle: (1pc) 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min LTD operating time at-125% 0s(TL=150s set) 6s(TL=s set) 400s(TL= 60s set) 0s(TL= 12s set) Operating characteristics NF1600-SEW Current setting Rated Current Ir: A In:1600A (Adjustable) Left-side mounting Operating hle Right-side AL mounting AX SHT or UVT Lead wire direction PAL Other Operating time 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip In x( ) ±10% Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) INST pickup current II x (4-12) ±15% (Magnification to In) LTD operating time TL s ±20% (at 200%) STD pickup current Is In x( ) ±15% STD operating time Ts 0.3 ± 0.06s 0.2 ± 0.04s 0.1 ± 0.03s 0.06 ± 0.02s Max. total breaking time Current (% of Ir) Instantaneous tripping current (% of In) External Current Reducing Curve Continuous load current (%) Rated ambient temperature Ambient temperature ( C) (An order for should be placed at the same time as an order of circuit breaker main body.) Type name Type name 3P F10SW Auxiliary hle HT HT-10SW Operating hle F 4P F10SW4P Hle lock device HL HL () 3P MI-16SW3 3P Mechanical interlock MI Electrical operation device NFM (*1) 4P MI-16SW4 4P Note *1 Specify the operation method voltage. Order in combination with the breaker unit.

137 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Insulating barrier 60 (removable) 3 (15.5) f11 Mounting hole (15.5) Conductor thickness t=6w75 max N Bolt M1065 Auxiliary hle (removable) 346 Neutral pole 17 f17.5 f M tap or f10 Drilling plan 375 R mm clearance on each side of the hle frame. Front-panel cutout Rear connection allowance Stud can be rotated Mounting angle Conductor thickness t=6w75 max allowance f11 BM1050 bolt Stud can be rotated Mounting angle Conductor thickness t=6w75 max. f11 M1050 bolt M tap or f10 Drilling plan Mounting angle 160 min. max Other

138 79 Low-voltage NF1600-SDW NF1600-SDW Model NF1600-SDW Rated current In (Amp.) 1600 Number of poles 2 Rated insulation voltage Ui (V) 690 Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Time constant not large than 10msec Stard Attached parts DC 250V 40/20 Front connection Rear connection Mounting screw: M 40 (4pcs) Insulating barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs) Auxiliary hle: (1pc) Mounting screw: M 40 (4pcs) Auxiliary hle: (1pc) Operating 3h 2h Other Operating time 1h 40min 20min 10min 6min 4min 2min 1min 40s 30s 20s 10s 6s 4s 2s 1s 0.6s 0.4s 0.2s 0.1s 0.06s 0.04s Max. allowable current carrying time Operating characteristics of NF1600-SDW, magnetic trip only, 1600 A Adjustable range of instantaneous tripping current (4 stages) Position of adjusting knob L0 2 3 Hi Instantaneous tripping current (A) 3200±00 400± ±00 000±00 Max. total breaking time 0.02s Instantaneous trip 0.01s Current (% of rated current) External Internal Left-side mounting Operating hle (An order for should be placed at the same time as an order of circuit breaker main body.) Type name Type name 2, 3P F10SW Auxiliary hle HT HT-10SW Operating hle F 4P F10SW4P Hle lock device HL HL () 2, 3P MI-16SW3 2, 3P Mechanical interlock MI Electrical operation device NFM (*1) 4P MI-16SW4 4P Note *1 Specify the operation method voltage. Order in combination with the breaker unit. Right-side mounting AL EAL AX TBL SHT or UVT TBM PAL MG ATU Lead wire direction

139 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Insulation barrier (removable) (15.5) Trip button f Rear connection 140 (15.5) Mounting 210 hole 20 Stud can be turned Mounting angle Same dimensions as NF1600-SEW allowance f17.5 f Drilling plan Differing in external dimensions from NF1600-SEW. allowance Conductor thickness t=6width 75 max. f11 Bolt M1050 Conductor thickness t=6width 75 max. Bolt M1065 Auxiliary hle (removable) Stud in horizontal direction. It cannot be turned Mounting angle f11 Bolt M1050 Conductor thickness t=6width 75 max M screw or f10 R M screw or f10 Drilling plan Remarks: 1. Stard specification of NF1600-SDW is 2-pole model. models are available for DC special voltage pole models are models with the central pole removed. 97 Front-panel cutout Mounting angle 160 or more 175 or more mm clearance on each side of the hle frame Other

140 00 NV32-SV NV63-CV NV63-SV NV63-HV NV63-SV Operating Model NV32-SV NV63-CV NV63-SV NV63-HV Rated current In (A) (5) 6 10 (15) (30) 32 (5) (10) (15) (30) (60) 63 (5) (10) (15) (30) (60) 63 (15) (30) (60) 63 Number of poles Phase line 3f3W, 1f2W 1f2W 3f3W, 1f2W 1f2W 3f3W, 1f2W 3f3W, 1f2W Rated operational voltage Ue (V) AC (15) 30 /200/500 selectable /200/500 selectable (15) 30 (15) 30 /200/500 selectable (15) 30 /200/500 selectable Rated current sensitivity (ma) 30 High-speed type at IΔn Max operating time (s) at 5IΔn Rated current sensitivity (ma) Time-delay type Max operating time (s) Inertial operating time (s) (or more) Earth-leakage indication system Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) 440V 5/5 2.5/ /7.5 10/ 415V 5/5 2.5/ /7.5 10/ Rated short-circuit IEC V 5/5 5/5 7.5/7.5 10/ AC breaking (Icu/Ics) 230V 10/10 7.5/7.5 15/15 25/19 capacity (ka) 200V 10/10 7.5/7.5 15/15 25/19 V 10/10 7.5/7.5 15/15 25/19 Stard attached parts (Front connection) Mounting screw: M (2pcs) (*1) Insulation barrier: (2P: 1pc, 3P: 2pcs) Note *1 Attached to NV63-SV NV63-HV. 4h 4h 4h Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s Min. Max. Operating NV32-SV 6A Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s Min. Max. Operating NV32-SV 10A-32A NV63-CV 16A-32A NV63-SV 16A-32A NV63-HV 16A-32A Instantaneous trip current is fixed to 600A120A. Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s Min. Operating NV63-CV 40A-63A NV63-SV 40A-63A NV63-HV 40A-63A Max. (60A-63A) Max. (40A-50A) 0.5s 0.5s 0.5s Other 0.2s 0.1s 0.05s 0.02s Time-delay trip Instantaneous trip 0.01s % of rated current External Max. total breaking time Earth leakage Tripping Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.04s 0.02s 0.01s Rated nonoperating current High-speed type Rated current sensitivity Ground-fault current ( % of rated current sensitivity) 0.2s 0.1s 0.05s 0.02s 0.01s Time-delay trip Instantaneous trip % of rated current Max. total breaking time Internal Temperature Compensation Curve Current rating (%) Ambient temperature ( C) 0.2s 0.1s 0.05s 0.02s 0.01s Left-side mounting Time-delay trip Operating hle % of rated current Right-side mounting Max. total breaking time Instantaneous trip Type name Type name F F-05SV Mechanical interlock MI MI-05SV3 Operating hle V V-05SV Small TC-S TCS-05SV3 LC LC-05SV TCL-05SV3 Large TC-L HLF-05SV Terminal TCL-05SV3L Hle lock device HL (*1) HLN-05SV cover Skeleton TTC TTC-05SV3 HL-S HLS-05SV Rear BTC BTC-05SV3 Note *1 HLF types are used for OFF lock HLN types for ON lock. Plug-in PTC PTC-05SV3 IEC 35mm rail mounting adapters DIN-05SV 0 Rated ambient temperature AL AX SHT or UVT Lead-wire direction TBM Internal Wiring Diagram Line side Magnetic device Test button Leakage indication button ZCT Senstivity selector Load side

141 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole 112 Trip button Insulation barrier (removable) Sensitivity current selector Leakage indication button Test button M50. screw (M for 60 63A) 4 50 f f4.5 Applicable wire size: f1.6 to 22mm 2 (for M50. screw) f5.5 (f.5 for 60 63A) 12.5 max. (16 max. for 60A 63A) (Conductor thickness t=4 max.) Conductor drilling for direct connection M40.7 taps or f5 25 Drilling plan 111 Rear connection Mounting plate t = 3.2 max. Mounting base 43 (44 for 60A 63A) 112 M40.7 taps or f R min. M6 screw 50 M40.7 breaker mounting screw 25 f (46 for 60A 63A) 50 Drilling plan 1.0mm clearance on each side of the hle frame Front-panel cutout Plug-in Plug-in terminal block Mounting plate M50. terminal block mounting screw 0 50 (plug-in terminal block) Other max. 21 M6 screw f6.5 2 f6 hole or M50. taps Details of terminal Conductor drilling Drilling plan Remark: 1. 2-pole models are models with the central pole removed.

142 02 NV125-CV NV125-SV NV125-HV 4h NV125-SV Operating Model NV125-CV NV125-SV NV125-HV (15) (15) (30) Rated current In (A) (60) 63 (75) (60) 63 (75) (*2) (60) (*2) Number of poles Phase line 4h 3f3W, 1f2W 4h 3f3W, 1f2W 3f4W 3f3W, 1f2W Rated operational voltage Ue (V) AC (15) 30 /200/500 selectable 30 /200/500 selectable 3f4W (30) /200/500 selectable Rated current sensitivity (ma) High-speed type at IΔn Max operating time (s) at 5IΔn Rated current sensitivity (ma) (/200/500 selectable) (/200/500 selectable) (/200/500 selectable) Time-delay type Max operating time (s) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) Inertial operating time (s) (or more) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) Earth-leakage indication system Mechanical type (button) Mechanical type (button) Mechanical type (button) 440V 10/5 25/25 50/3 415V 10/5 30/30 50/3 Rated short-circuit IEC V 10/5 30/30 50/3 AC breaking (Icu/Ics) 230V 30/15 50/50 /75 capacity (ka) 200V 30/15 50/50 /75 V 30/15 50/50 /75 Stard attached parts (Front connection) Mounting screw: M (3P: 2pcs, 4P: 4pcs) (*1) Insulation barrier: (3P: 2pcs, 4P: 3pcs) Notes *1 Attached to NV125-SV NV125-HV. *2 In case of time delay type, rated current is produced with 20 amp. or more. Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s Min. Max. Operating NV125-SV 15A-30A NV125-HV 15A-30A Instantaneous trip current is fixed to 600A120A. Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s Min. Operating NV125-CV 60A-A NV125-SV 40A-A NV125-HV 40A-A Max. (60A-A) Max.(40A-50A) Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s Min. Operating NV125-CV 125A NV125-SV 125A NV125-HV 125A Max. Other 0.2s 0.1s 0.05s 0.02s Time-delay trip Instantaneous trip 0.01s % of rated current External Max. total breaking time Earth leakage Tripping Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.04s 0.02s 0.01s Rated nonoperating current High-speed type Rated current sensitivity Rated current sensitivity Rated nonoperating current Time-delay type 0.45s (Max) Inertial nonoperating time Rated nonoperating current Rated current sensitivity Time-delay type 1s (Max) Inertial nonoperating time Ground-fault current(% of rated current sensitivity) Rated nonoperating current Rated current sensitivity Time-delay type 2s (Max) Inertial nonoperating time 0.2s 0.1s 0.05s 0.02s Time-delay trip Instantaneous trip 0.01s % of rated current Max. total breaking time Internal Temperature Compensation Curve Current rating (%) 0.2s 0.1s 0.05s 0.02s 0.01s Time-delay trip Instantaneous trip % of rated current Operating hle Type name Type name Operating hle F F-1SV 3P MI-05SV3 Mechanical interlock MI V V-1SV 4P MI-1SV4 LC LC-05SV Small TC-S TCS-1SV3 Hle lock device HL (*1) HLF-05SV 3P TCL-1SV3 Large TC-L HLN-05SV Terminal 4P TCL-1SV4 HL-S HLS-05SV cover Skeleton TTC TTC-1SV3 Notes *1 HLF types are used for OFF lock HLN types for ON lock. Rear BTC BTC-1SV3 *2 Specify the working voltage. Plug-in PTC PTC-1SV3 Electrical operation device (*2) Rated ambient temperature Ambient temperature ( C) Left-side mounting Right-side mounting Max. total breaking time AL AX SHT or UVT Lead-wire direction TBM Internal Wiring Diagram Line side Magnetic device Leakage indication button Test button Senstivity selector ZCT Load side

143 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole 112 Trip button Rear connection Insulation barrier (removable) Operating time selector (for time-delay type) Sensitivity current selector Leakage indication button Test button f.5 50 Neutral pole 4 M screw f Solderless terminal for wire size 14-2/0AWG CU/AL Wire connection f.5 19 max. Comb conductor 16.5 max. (Conductor thickness t=4 max.) Conductor drilling for direct connection M40.7 taps or f5 Drilling plan 111 Mounting plate t = 3.2 max Mounting base Stud can be rotated connection allowance M bolt Insulating tube M40.7 breaker mounting screw f1 Drilling plan M40.7 taps or f R Front-panel cutout 1.0mm clearance on each side of the hle frame Plug-in 5.5 Mounting plate Plug-in terminal block M50. terminal block mounting nut or screw mounted directly max. 12 (plug-in terminal block) Other Details of terminal M screw f.5 Conductor drilling f6 hole or M50. taps Drilling plan Remark: 1. Only models are available for NV125-CV.

144 04 NV250-CV NV250-SV NV250-HV NV250-CV Model NV250-CV NV250-SV NV250-HV Rated current In (A) Number of poles Phase line 3f3W, 1f2W 3f3W, 1f2W 3f4W 3f3W, 1f2W Rated operational voltage Ue (V) AC /200/500 selectable (30) /200/500 selectable 3f4W (30) /200/500 selectable Rated current sensitivity (ma) High-speed type at IΔn Max operating time (s) at 5IΔn Rated current sensitivity (ma) (/200/500 selectable) (/200/500 selectable) (/200/500 selectable) Time-delay type Max operating time (s) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) Inertial operating time (s) (or more) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) Earth-leakage indication system Mechanical type (button) Mechanical type (button) Mechanical type (button) 440V 15/12 36/36 65/65 415V 25/19 36/36 / Rated short-circuit IEC V 25/19 36/36 75/75 AC breaking (Icu/Ics) 230V 36/27 5/5 / capacity (ka) 200V 36/27 5/5 / V 36/27 5/5 / Stard attached parts (Front connection) Mounting screw: M (3P: 2pcs, 4P: 4pcs) Insulation barrier: (3P: 4pcs, 4P: 6pcs) Operating Earth leakage Tripping 4h 4h Other Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. Operating NV250-CV 125A-225A NV250-SV 125A-225A NV250-HV 125A-225A Max. 0.02s 0.02s Time-delay trip Instantaneous trip Time-delay trip Instantaneous trip 0.01s 0.01s % of rated current Internal Left-side mounting Operating hle Right-side mounting External AL AX SHT or UVT TBM Max. total breaking time Operating time Lead-wire direction 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. % of rated current Operating NV250-CV 250A NV250-SV 250A NV250-HV 250A Max. Max. total breaking time Temperature Compensation Curve Current rating (%) Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.04s 0.02s 0.01s Rated nonoperating current High-speed type Rated current sensitivity Rated current sensitivity Rated nonoperating current Time-delay type 0.45s (Max) Inertial nonoperating time Ground-fault current(% of rated current sensitivity) Type name Type name Operating hle F F-2SV 3P MI-05SV3 Mechanical interlock MI V V-2SV 4P MI-2SV4 LC LC-05SV Small TC-S 3P TCS-2SV3 Hle lock device HL (*1) HLF-05SV TCL-2SV3 3P HLN-05SV Large TC-L TCL-2SV3L HL-S HLS-2SV Terminal cover 4P TCL-2SV4 Notes *1 HLF types are used for OFF lock HLN types for ON lock. Skeleton TTC 3P TTC-2SV3 *2 Specify the working voltage. Rear BTC 3P BTC-2SV3 Plug-in PTC 3P PTC-2SV3 Electrical operation device (*2) Ambient temperature ( C) Rated ambient temperature Rated nonoperating current Rated current sensitivity Time-delay type 1s (Max) Inertial nonoperating time Rated nonoperating current Rated current sensitivity Time-delay type 2s (Max) Inertial nonoperating time Internal Wiring Diagram Line side Magnetic device Test button Senstivity selector Leakage indication button ZCT Load side

145 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing 165 Front connection 144 Trip button Mounting hole Rear connection Insulation barrier (removable) Operating time selector (for time-delay type) Sensitivity current selector Leakage indication button Test button Neutral pole M bolt (hex-socket) 50 f f C1 30 Solderless terminal for wire size A 14-95mm A -125mm 2 Wire connection f.5 Or f.5 C max max. (Conductor thickness t=7 max.) Conductor drilling for direct connection 35 M40.7 taps or f5 35 Drilling plan 126 Mounting base Mounting plate t = 3.2 max. Stud can be rotated connection allowance R Plug-in f9 M bolt M40.7 breaker mounting screw Insulation tube 35 f24 M40.7 taps or f5 Drilling plan mm clearance on each side of the hle frame Front-panel cutout Mounting plate Plug-in terminal block 11 6 M5 terminal block mounting screw connection allowance Insulation barrier f9 M bolt Stud attachable in this direction only Drilling plan f6 hole or M50. taps Other Remark: 1. Only models are available for the model of NV250-CV.

146 06 NV125-SEV NV125-HEV NV250-SEV NV250-HEV Model NV125-SEV NV125-HEV NV250-SEV NV250-HEV Rated current In (A) Current setting Ir (A) Number of poles Phase line type 3f3W, 1f2W 3f4W 3f3W, 1f2W 3f4W 3f3W, 1f2W 3f3W, 1f2W Rated operational voltage Ui V Rated operational voltage Ue (V) AC Rated current sensitivity (ma) Max operating time (s) (30) /200/500 selectable (30) /200/500 selectable (30) /200/500 selectable (30) /200/500 selectable High-speed type at IΔn at 5IΔn Rated current sensitivity (ma) (/200/500 selectable) (/200/500 selectable) (/200/500 selectable) (/200/500 selectable) Time-delay type Max operating time (s) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) (0.45/1.0/2.0 selectable) Inertial operating time (s) (or more) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) (0.1/0.5/1.0) Earth-leakage indication system Mechanical type (button) Mechanical type (button) Mechanical type (button) Mechanical type (button) 440V 36/36 65/65 36/36 65/65 Rated 415V 36/36 / 36/36 / short-circuit IEC V 36/36 75/75 36/36 75/75 AC breaking (Icu/Ics) 230V 5/5 / 5/5 / capacity (ka) 200V 5/5 / 5/5 / V 5/5 / 5/5 / Stard attached parts (Front connection) Mounting screw: M (3P: 2pcs, 4P: 4pcs) Insulation barrier: (3P: 4pcs, 4P: 6pcs) NV250-SEV Operating Earth leakage Tripping Other Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 10h 5h Operating Operating NV250-SEV NV250-HEV NV125-SEV NV125-HEV 2h Current setting Ir Rated current In Current setting Ir Rated current In 1h A A LTD operating time at 125% (I 6 t ON) 30min LTD operating time at 125% (I 6 t ON) 6s (TL = s set) 20min 6s (TL = s set) 14min 540s (TL = 0s set) 10min 540s (TL = 0s set) 400s (TL = 60s set) 6min 400s (TL = 60s set) 0s (TL = 12s set) 4min 0s (TL = 12s set) 2min LTD operating time TL 1min LTD operating time TL I 6 t ON 12600s ±20% I 6 t ON 12600s ±20% (at 200%) 30s (at 200%) 20s I 6 t OFF I 6 t OFF 10s STD pickup current Is STD pickup current Is Ir( s Ir( )±15% 56710)±15% 2s 1s STD operating time Ts 0.5s STD operating time Ts 0.3±0.06s 0.3±0.06s 0.2±0.04s 0.2s 0.2±0.04s I 2 t ON 0.1±0.03s 0.1s I 2 t ON 0.1±0.03s 0.05s I 2 t OFF I 2 t OFF INST pickup current Ii 0.02s INST pickup current Ii In2-14 ±15%, Ir14 ±15% Max. total breaking time In2-14 ±15%, Ir14 ±15% Max. total breaking time 0.01s % of current setting Ir % of current setting Ir Instantaneous tripping current Instantaneous tripping current (% of rated current or % of current setting Ir) (% of rated current or % of current setting Ir) Internal Left-side mounting Operating hle Right-side mounting External AL AX SHT or UVT TBM PAL Operating time Lead-wire direction (Note *1) (Note *2) Notes *1 For the 24VDC TBM only instruct us of a control voltage. (The stard shared voltage is -240VAC/-240VDC.) *2 SLT-equipped is stard. Control voltage (-200VAC) is necessary. Current Reducing Curve Current rating (%) Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.04s 0.02s 0.01s Rated nonoperating current High-speed type Rated current sensitivity Rated current sensitivity Rated nonoperating current Time-delay type 0.45s (Max) Inertial nonoperating time Ground-fault current(% of rated current sensitivity) Type name Type name Operating hle F F-2SV 3P MI-05SV3 Mechanical interlock MI V V-2SV 4P MI-2SV4 LC LC-05SV Small TC-S 3P TCS-2SV3 Hle lock device HL (*1) HLF-05SV TCL-2SV3 3P HLN-05SV Large TC-L TCL-2SV3L HL-S HLS-2SV Terminal cover 4P TCL-2SV4 Notes *1 HLF types are used for OFF lock HLN types for ON lock. Skeleton TTC 3P TTC-2SV3 *2 Specify the working voltage. Rear BTC 3P BTC-2SV3 Plug-in PTC 3P PTC-2SV3 Electrical operation device (*2) Rated ambient temperature Ambient temperature ( C) The rated current does not have thermal characteristics. Reduce the current as shown in the curve on the left chart if the ambient temperature exceeds 40 C. 60 Rated nonoperating current Rated current sensitivity Time-delay type 1s (Max) Inertial nonoperating time Rated nonoperating current Rated current sensitivity Time-delay type 2s (Max) Inertial nonoperating time Internal Wiring Diagram Magnetic device Line side Magnetic device Characteristic setting part CT CT CT Leakage indication button Test button ZCT Senstivity selector Load side

147 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing 165 Front connection Mounting hole 144 Trip button Rear connection Insulation barrier (removable) Operating time selector (for time-delay type) Sensitivity current selector Leakage indication button Test button Trip characteristics selector Neutral pole 102 M bolt (hex-socket) 50 f f4.5 C1 30 Solderless terminal for wire size A 14-95mm A -125mm 2 Wire connection f.5 Or f.5 C max max. (Conductor thickness t=7 max.) Conductor drilling for direct connection 35 M40.7 taps or f5 35 Drilling plan 126 Mounting plate t = 3.2 max. Mounting base Stud can be rotated connection allowance R f9 M bolt M40.7 breaker mounting screw Insulation tube 35 f24 M40.7 taps or f Drilling plan mm clearance on each side of the hle frame Front-panel cutout Plug-in Mounting plate Plug-in terminal block 11 6 M5 terminal block mounting screw connection allowance Insulation barrier f9 M bolt Stud attachable in this direction only Drilling plan f6 hole or M50. taps Other Remark: 1. Only models are available for the model of NV250-SEV NV250-HEV.

148 0 NV400-CW NV400-SW NV400-SW Operating Model NV400-CW NV400-SW Number of poles 3 Rated operational voltage Ue (V AC) (*1) -440 Multi-voltage type Rated current In (A) High-speed type Time-delay type Rated current sensitivity IΔn (ma) (30) Selectable Max. operating time at 5IΔn (s) 0.04 Rated current sensitivity IΔn (ma) Max. operating time at 2IΔn (s) ( Selectable) ( Selectable) Inertial non-operating time at 2IΔn (s) ( ) Earth-leakage indication system Button Rated short-circuit 440V 25/13 42/42 breaking capacity (ka) IEC (lcu/lcs) AC 400V 36/1 45/45 EN V 50/25 5/5 Stard attached parts (Front connection) Mounting screw: M6 60 (4pcs) Insulation barrier: (4pcs) Note *1 Rated operational voltage of time-delay type is for V. Tripping 4h Other Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Min. Time-delay trip Max Current (% of rated current) Internal Left-side mounting Operating hle Right-side mounting External Operating characteristics NV400-CW NV400-SW NV400-CW NV400-SW Max. total breaking time Instantaneous trip AL AX SHT or UVT TBM Lead wire direction Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.04s 0.02s 0.01s Rated nonoperating current Rated current sensitivity Highspeed type Type name Type name F F-4S Auxiliary hle HT HT-4CW, HT-4SW Operating hle V V-4S Large TC-L TCL-4SW3 Terminal Mechanical interlock MI MI-4SW3 Skeleton TTC TTC-4SW3 cover Note *1 Specify the operation method voltage. Rear BTC BTC-4SW3 Order in combination with the breaker unit. HL HL-4CW, HL-4SW Hle lock device HL-S HLS-4SW Electrical operation device (*1) Rate nonoperating current Time-delay type 0.45s. (MAX) Rate current sensitivity Inertial nonoperating time Rate nonoperating current Time-delay type 1s. (MAX) Rate current sensitivity Inertial nonoperating time Time-delay type 2s. (MAX) Ground-fault current (% of rated current sensitivity) Rate nonoperating current Rate current sensitivity Inertial nonoperating time Temperature Compensation Curve Current rating (%) Rated ambient temperature Ambient temperature ( C) Internal Wiring Diagram Line side Magnetic device Test button 50 Sensitivity selector ZCT 60 Load side Leakage indication button

149 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection 110 Mounting hole LC Trip button Insulating barrier (removable) Sensitivity current selector Operating time selector (Time-delay type) Leakage indication button Test button f14 M12 bolt Conductor thickness t= max f12.5 f (NV400-SP) 134(NV400-CP) f10.5 Conductor thickness t= max. Conductor drilling for direct connection LC LC M6 tap or f7 Drilling plan LC R6 LC mm clearance on each side of the hle frame. Front-panel cutout Rear connection Boring dimensions for rear connection type barriers () Mounting plate Stud can be rotated 90 Groove for reducing heat by overcurrent LC Line side 6-f LC 113 allowance f13 M12 bolt M6 tap or f7 Insulation tube LC M6 screw for mounting breaker 44 7 f35 Drilling plan Load side M6 tap or f7 -M4 screw Add these tapped holes in positions to stard boring. Note The bore dimensional drawing shows the breaker viewed from the rear. Other

150 10 NV400-SEW NV400-HEW NV400-REW NV400-SEW Operating Model NV400-SEW NV400-HEW NV400-REW Number of poles Rated operational voltage Ue (V AC) (*1) Rated current In (A) High-speed type Time-delay type Rated current sensitivity IΔn (ma) -440 Multi-voltage type adjustable (30) Selectable Max. operating time at 5IΔn (s) 0.04 Rated current sensitivity IΔn (ma) Max. operating time at 5IΔn (s) ( Selectable) ( Selectable) Max. inertial non-operating time at 2IΔn (s) ( ) Earth-leakage indication system Button Rated short-circuit 440V 42/42 65/65 125/63 breaking capacity (ka) IEC (Icu/Ics) AC 400V 50/50 / 125/63 EN V 5/5 / 150/75 Stard attached parts (Front connection) Mounting screw: M6 72 (4pcs) Insulation barrier: (3P: 4pcs, 4P: 6pcs) Note *1 Rated operational voltage of time-delay type is for V. Tripping Other Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip Ir x ( ) ±10% Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) LTD operating time at 125% 0s (TL=150s set) 6s (TL=s set) 400s (TL= 60s set) 0s (TL= 12s set) INST pickup current II x 4 - x16 ±15% (Magnification to In) Operating characteristics NV400-SEW NV400-HEW NV400-REW Current setting Ir: A (Adjustable) Rated current In: 400A LTD operating time TL s ±20% (at 200%) STD operating time Ts 0.3 ± 0.06 s 0.2 ± 0.04 s 0.1 ± 0.03 s 0.06 ± 0.02 s Max. total breaking time Current setting (% of Ir) Instantaneous tripping current (% of In) Internal Left-side mounting Operating hle Right-side mounting AL PAL AX SHT or UVT TBM Remarks: 1. Instead of TBM, pre-alarm module (PAL) can be attached. External Operating time Lead wire direction 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.04s 0.02s 0.01s Rated nonoperating current Rated current sensitivity STD pickup current Is Ir x ( ) ±15% Highspeed type Type name Type name F F-4S Auxiliary hle HT HT-4SW Operating hle V V-4S 3P TCL-4SW3 (*1) Large TC-L 3P MI-4SW3 4P TCL-4SW4 (*1) Mechanical interlock MI 4P MI-4SW4 Terminal 3P TTC-4SW3 Skeleton TTC Notes *1 This is for NV400-SEW. cover 4P TTC-4SW4 *2 This is for NV400-SEW. For rear terminal 3P BTC-4SW3 (*2) cover of NV400-HEW/REW, use PTC-4SW3. Rear BTC *3 Specify the operation method voltage. 4P BTC-4SW4 *3 Order in combination with the breaker unit. HL HL-4SW Hle lock device HL-S HLS-4SW Electrical operation device NVM 3P (*3) 4P Rate nonoperating current Time-delay type 0.45s. (MAX) Rate current sensitivity Inertial nonoperating time Rate nonoperating current Time-delay type 1s. (MAX) Rate current sensitivity Inertial nonoperating time Ground-fault current (% of rated current sensitivity) Current Reducing Curve Continuous load current (%) Rated ambient temperature Rate nonoperating current Ambient temperature ( C) Time-delay type 2s. (MAX) Rate current sensitivity Inertial nonoperating time Internal Wiring Diagram Magnetic device N Line side Magnetic device Characteristic setting part CT CT CT Test button ZCT Sensitivity selector In case of 4P Load side Leakage indication button

151 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection 110 Mounting hole LC Trip button Insulating barrier (removable) Sensitivity current selector Operating time selector (Time-delay type) Leakage indication button Test button f14 M12 bolt LC Conductor thickness t= max Neutral pole f f f10.5 Conductor thickness t= max. Conductor drilling for direct connection LC LC 44 M6 tap or f7 44 Drilling plan LC 194 LC R6 LC mm clearance on each side of the hle frame. 92 Front-panel cutout Rear connection Boring dimensions for rear connection type barriers () LC 113 Mounting plate allowance Stud can be rotated f13 M12 bolt M6 tap or f7 Insulation tube LC M6 screw for mounting breaker Groove for reducing heat by overcurrent LC C L 44 f Drilling plan Line side Load side f M6 tap or f7 -M4 screw Add these tapped holes in positions to stard boring. Note The bore dimensional drawing shows the breaker viewed from the rear. Other

152 12 NV630-CW NV630-SW NV630-SW Operating Model NV630-CW NV630-SW Number of poles 3 Rated operational voltage Ue (V AC) -440 Multi-voltage type Rated current In (A) High-speed type Time-delay type Rated current sensitivity IΔn (ma) Max. operating time at 5IΔn (s) Rated current sensitivity IΔn (ma) Max. operating time at 5IΔn (s) Tripping Selectable Selectable Max. inertial non-operating time at 2IΔn (s) Earth-leakage indication system Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) EN Stard attached parts (Front connection) AC Button 440V 36/1 42/42 400V 36/1 50/50 230V 50/25 5/5 Mounting screw: M6 72 (4pcs) Insulation barrier: (4pcs) 4h Other Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 125 Min. Time-delay trip Internal Left-side mounting Operating hle Right-side mounting Operating characteristics NV630-CW NV630-SW Max. Max. total breaking time Instantaneous trip % of rated current AL AX SHT or UVT TBM External 4000 Lead wire direction Type name Type name F F-4S Auxiliary hle HT HT-4SW Operating hle V V-4S Large TC-L TCL-4SW3 Terminal Mechanical interlock MI MI-4SW3 Skeleton TTC TTC-4SW3 cover Note *1 Specify the operation method voltage. Rear BTC BTC-4SW3 Order in combination with the breaker unit. HL HL-4SW Hle lock device HL-S HLS-4SW Electrical operation device (*1) Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.04s 0.02s 0.01s Rate nonoperating current Time-delay type 0.45s. (MAX) Rate current sensitivity Inertial nonoperating time Rate nonoperating current Time-delay type 1s. (MAX) Rate current sensitivity Inertial nonoperating time Rate nonoperating current Ground-fault current (% of rated current sensitivity) Time-delay type 2s. (MAX) Rate current sensitivity Inertial nonoperating time Temperature Compensation Curve Current rating (%) Rated ambient temperature Ambient temperature ( C) Internal Wiring Diagram Line side Magnetic device 50 Test button Sensitivity selector 60 ZCT Load side Leakage indication button

153 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing 110 Mounting hole Trip button Front connection Insulating barrier (removable) Sensitivity selector Operating-time selector (time-delay type) Leakage-indicator button Test button f14 M12 bolt Neutral Pole Conductor thickness t=10 max f f f10.5 Conductor thickness t=10 max. Conductor drilling for direct connection 44 M6 screw or f7 44 Drilling plan 194 R6 11 1mm clearance on each side of hle Front-plate cutout 92 Rear connection Boring dimensions for rear connection type barriers () Mounting plate allowance Stud can be rotated f13 M12 bolt M6 breaker mounting screw M6 screw or f7 7 Insulated tube Eddy-current heat-reducing slit f35 Drilling plan Line side Load side f M6 tap or f7 -M4 screw Add these tapped holes in positions to stard boring. Note The bore dimensional drawing shows the breaker viewed from the rear. Other

154 14 NV630-SEW NV630-HEW Operating 10h NV630-SEW Model NV630-SEW NV630-HEW Number of poles Rated operational voltage Ue (V AC) (*1) Rated current In (A) High-speed type Time-delay type Rated current sensitivity IΔn (ma) Max. operating time at 5IΔn (s) Rated current sensitivity IΔn (ma) Max. operating time at 5IΔn (s) -440 Multi-voltage type adjustable Tripping ( Selectable) ( Selectable) Max. inertial non-operating time at 2IΔn (s) ( ) Earth-leakage indication system Button Rated short-circuit 440V 42/42 65/65 breaking capacity (ka) IEC (Icu/Ics) AC 400V 50/50 / EN V 5/5 / Stard attached parts (Front connection) Mounting screw: M6 72 (4pcs) Insulation barrier: (3P: 4pcs, 4P: 6pcs) Note *1 Rated operational voltage of time-delay type is for V. Other Operating time 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip Ir x( )±10% Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) INST pickup current II In x(4-15) ±15% (Magnification to In) LTD operating time at-125% 0s(TL=150s set) 5s(TL=s set) 400s(TL= 60s set) 0s(TL= 12s set) Operating characteristics NV630-SEW NV630-HEW Current setting Ir: A (Adjustable) Rated Current In:630A LTD operating time TL s ±20% (at 200%) STD pickup current Isd Ir x( ) ±15% STD operating time Ts 0.3 ± 0.06s 0.2 ± 0.04s 0.1 ± 0.03s 0.06 ± 0.02s Max.total breaking time Current (% of Ir) Instantaneous Tripping Current (% of In) Internal Left-side mounting Operating hle Right-side mounting AL PAL AX SHT or UVT TBM Remarks: 1. Instead of TBM, pre-alarm module (PAL) can be attached. External Lead wire direction Type name Type name F F-4S Auxiliary hle HT HT-4SW Operating hle V V-4S 3P TCL-4SW3 (*1) Large TC-L 3P MI-4SW3 4P TCL-4SW4 (*1) Mechanical interlock MI 4P MI-4SW4 Terminal 3P TTC-4SW3 Skeleton TTC Notes *1 This is for NV630-SEW. cover 4P TTC-4SW4 *2 This is for NV630-SEW. For rear terminal 3P BTC-4SW3 (*2) cover of NV630-HEW, use PTC-4SW3. Rear BTC *3 Specify the operation method voltage. 4P BTC-4SW4 *3 Order in combination with the breaker unit. HL HL-4SW Hle lock device HL-S HLS-4SW Electrical operation device NVM 3P (*3) 4P Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.04s 0.02s 0.01s Rate nonoperating current Time-delay type 0.45s. (MAX) Rate current sensitivity Inertial nonoperating time Rate nonoperating current Time-delay type 1s. (MAX) Rate current sensitivity Inertial nonoperating time Rate nonoperating current Ground-fault current (% of rated current sensitivity) Current Reducing Curve Continuous load current (%) Rated ambient temperature Time-delay type 2s. (MAX) Rate current sensitivity Ambient temperature ( C) Inertial nonoperating time Internal Wiring Diagram Magnetic device N Line side Magnetic device Characteristic setting part CT CT CT Test button ZCT Sensitivity selector In case of 4P Load side Leakage indication button

155 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing 110 Mounting hole Trip button Front connection Insulating barrier (removable) Sensitivity selector Operating-time selector (time-delay type) Leakage-indicator button Test button f14 M12 bolt Neutral Pole Conductor thickness t=10 max f f f10.5 Conductor thickness t=10 max. Conductor drilling for direct connection 44 M6 screw or f7 44 Drilling plan 194 R6 11 1mm clearance on each side of hle Front-plate cutout 92 Rear connection Boring dimensions for rear connection type barriers () Mounting plate allowance Stud can be rotated f13 M12 bolt M6 breaker mounting screw M6 screw or f7 7 Insulated tube Eddy-current heat-reducing slit f35 Drilling plan Line side Load side f M6 tap or f7 -M4 screw Add these tapped holes in positions to stard boring. Note The bore dimensional drawing shows the breaker viewed from the rear. Other

156 16 NV00-SEW NV00-HEW 10h NV00-SEW Operating Model NV00-SEW NV00-HEW Number of poles 3 Rated operational voltage Ue (V AC) Rated current In (A) High-speed type Time-delay type Rated current sensitivity IΔn (ma) Max. operating time at 5IΔn (s) Rated current sensitivity IΔn (ma) Max. operating time at 5IΔn (s) -440 Multi-voltage type adjustable Tripping Selectable Selectable Max. inertial non-operating time at 2IΔn (s) Earth-leakage indication system Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) EN Stard attached parts (Front connection) AC Button 440V 42/42 65/65 400V 50/50 / 230V 5/5 / Mounting screw: M6 35 (4pcs) Insulation barrier: (2pcs) Other Operating time 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip Ir ( ) ±10% Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) LTD operating time at-125% 0s(TL=150s set) 6s(TL=s set) 400s(TL= 60s set) 0s(TL= 12s set) INST Pickup current Ii In x(4-10) ±15% (Magnification to In) Internal Left-side mounting Operating hle Right-side mounting Current (% of Ir) Instantaneous Tripping Current (% of In) AL PAL AX Operating characteristics NV00-SEW NV00-HEW Current setting Ir:400-00A (Adjustable) SHT or UVT Rated Current In:00A LTD operating time TL s ±20% (at 200%) STD pickup current Isd Ir ( ) ±15% STD operating time Ts 0.3 ± 0.06s 0.2 ± 0.04s 0.1 ± 0.03s 0.06 ± 0.02s Max.total breaking time TBM Lead wire direction Remarks: 1. Instead of TBM, pre-alarm module (PAL) or trip indicator (TI) can be attached. External Type name Type name F F-S Auxiliary hle HT HT-4SW Operating hle V V-S Large TC-L TCL-SW3 Terminal Mechanical interlock MI MI-SW3 Skeleton TTC TTC-SW3 cover Note *1 Specify the operation method voltage. Rear BTC BTC-SW3 Order in combination with the breaker unit. HL HL-4SW Hle lock device HL-S HLS-SW Electrical operation device (*1) Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.04s 0.02s 0.01s Rate nonoperating current Time-delay type 0.45s. (MAX) Rate current sensitivity Inertial nonoperating time Rate nonoperating current Time-delay type 1s. (MAX) Rate current sensitivity Inertial nonoperating time Rate nonoperating current Ground-fault current (% of rated current sensitivity) Current Reducing Curve Working current correcting ratio (%) Rated ambient temperature Ambient temperature ( C) Time-delay type 2s. (MAX) Rate current sensitivity Inertial nonoperating time Internal Wiring Diagram Magnetic device Line side Magnetic device Characteristic setting part CT CT CT Test button ZCT Sensitivity selector Load side Leakage indication button

157 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button Insulating barrier (removable) Conductor thickness t=12 max. Sensitivity current selector Operating time selector (Time-delay type) Leakage indication button Test button f f f Terminal dimension for directly connecting conductor (Conductor thickness t=10 max.) Conductor drilling for direct connection 243 M6 tap or f7 Drilling plan R mm clearance on each side of the hle frame. Front-panel cutout Rear connection Boring dimensions for rear connection type barriers () allowance 25 Mounting plate Stud can be rotated f13 M12 bolt M6 screw for mounting breaker M6 tap or f7 140 Drilling plan Groove for reducing heat by overcurrent 10 5 f f M6 tap or f7 -M4 screw Add these tapped holes in positions to stard boring. Note The bore dimensional drawing shows the breaker viewed from the rear. Other

158 1 NF50-SVFU NV50-SVFU NF50-SVFU Rated short-circuit breaking capacity (ka) Model NF50-SVFU Model NV50-SVFU Rated current In (A) Rated ambient temperature 40 C (3) Rated current In (A) Rated ambient temperature 40 C (5) (10) Number of poles 2 3 Phase line 1f2W 3f3W Number of poles 2 3 1f2W Rated voltage VAC 240 UL Y/347V Rated voltage IEC UL 49 CSA C22.2 No.5-02 IEC EN (Icu/Ics) 40V VAC EN AC 40Y/277V Rated current sensitivity IΔn ma V 14 Pick-up current UL % of IΔn 120V Operating time (sec) within AT 5lΔn 0.04 (*1) Rated insulation voltage Ui V 440 Earth-leakage indication system Indicator window 690V UL 49 40V 500V CSA C22.2 AC 240V V 7.5/4 No V 14 AC 415V 10/5 440V 7.5/4 400V 10/5 IEC V 10/5 EN AC 30V 10/5 (Icu/Ics) 230V 15/ 15/ 230V 15/ V 15/ 15/ High-speed type Rated short-circuit breaking capacity (ka) Stard attached parts IEC35 rail mounting claws (Front connection) Note *1 0.1 for UL1053. Remark: 1. The mounting screws must be prepared by the user. (Recommended size: M (2 pcs).) Operating (The CE CCC characteristics are noted differently. Contact us for more information.) Tripping (The CE CCC characteristics are noted differently. Contact us for more information.) Other Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s Min. Max. (3A-30A) Operating (UL 49) NF50-SVFU, NV50-SVFU Max. (40A-50A) Time-delay trip Instantaneous trip 0.01s Internal NF50-SVFU 2-pole Hle of circuit breaker Left pole Right pole AL AX Current (% of Ir) SHT or UVT TBM NV50-SVFU 2-pole Outgoing direction of lead wires Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.04s 0.02s 0.01s Rated non-operating current Highspeed type Rated current sensitivity Ground fault current (% of rated current sensitivity) Temperature Compensation Curve Rated current compensation rate % NV50-SVFU (UL 1053) 0 Rated ambient temperature Ambient temperature C Internal Wiring Diagram Line side Magnetic device Leakage indication Test button Sensitivity selector ZCT Load side External Type name Type name 2P F-03SVUL2 Terminal 2P TCL-03SVU2 F Large TC-L 3P F-03SVUL cover 3P TCL-03SVU3 Operating hle 2P V-03SVUL2 V 3P V-03SVUL Hle lock device HL HLF-03SVU HL-S HLS-03SVU

159 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button Trip button pole (NF50-SVFU) Trip button pole Mounting hole Leakage current indicator window Test button Trip button (NV50-SVFU) Leakage current indicator window Test button M50. screw 3 f f max. f5.5 6 (Conductor thickness t=4 max.) Conductor drilling for direct connection Remarks: 1. The mounting screws are not enclosed with the breaker. 2. The wires cannot be connected directly. Compatible crimp terminals Applicable wire range (*1) Crimp terminal type (*2) 2 AWG (#) mm (60 C/75 C) M40.7screw C L or f5 C L C L C L JST R2-5 2-M5 V2-5 V2-M5 - R5.5-5 V5.5-5 R-5 R NK5 22-S5 22-S6 Tightening torque 22lb-in (2.5N m) NTM R2-5 R2-5M R3.5-5S R3.5-5L R5.5-5 R5.5-5S R5.5-5N R-5 R-5S R14-5 R14-5S R22-5S JST: Japan Solderless Terminal Mfg. Co. NTM: Nichifu Co., Ltd. Notes *1 14AWG or lager to comply with UL Stards. *2 When using with a wire connection, use the crimp terminal combination shown above. R1 27 C L 2.5 C L pole 2-pole 37 The drilling dimensions have a 1.0 mm clearance on each side of breaker window frame. 55 Drilling plan Front panel drilling plan Other

160 20 NF-CVFU NV-CVFU NF-CVFU Rated short-circuit breaking capacity (ka) Model NF-CVFU Model NV-CVFU Rated current In (A) Rated ambient temperature 40 C 60 () 75 (0) (90) Rated current In (A) 60 () 75 Rated ambient Number of poles 3 (0) (90) temperature 40 C 3f3W Phase line 1f2W Number of poles 2 3 UL Rated Rated voltage VAC 240 voltage VAC IEC Y/347V EN UL 49 40V 30/50/ CSA C22.2 Rated current sensitivity IΔn ma No.5-02 AC 40Y/277V /200/500 selectable 240V 14 Pick-up current UL % of IΔn 120V Operating time (sec) within AT 5lΔn 0.04 (*1) Rated insulation voltage Ui V 600 Earth-leakage indication system Mechanical button 690V UL 49 40V 500V 7.5/4 CSA C22.2 AC 240V 14 IEC V 10/5 No V 14 EN (Icu/Ics) AC 415V 10/5 440V 10/5 400V 10/5 IEC V 10/5 EN AC 30V 10/5 (Icu/Ics) 230V 15/ 230V 15/ V 15/ Stard attached parts (Front connection) Note *1 0.1 for UL1053. High-speed type Rated short-circuit breaking capacity (ka) IEC35 rail mounting claws, Insulating barrier (2P: 2pcs, 3P: 4pcs) (Only for type with bar terminal) Mounting screw M (2 screws) Other Operating (The CE CCC characteristics are noted differently. Contact us for more information.) Internal NF-CVFU 2-pole Operating time Hle of circuit breaker Left pole 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min Max. 1min 30s 20s 10s 5s Min. 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Time-delay trip Instantaneous trip Right pole External AL Current (% of Ir) AX Operating (UL 49) NF-CVFU NV-CVFU SHT or UVT TBM NV-CVFU Outgoing direction of lead wires Temperature Compensation Curve Rated current compensation rate % Type name Type name 2P F-05SVUL2 TCL-05SVU2 F 2P 3P F-05SVUL Terminal TCL-05SVU2L Operating hle Large TC-L 2P V-05SVUL2 cover TCL-05SVU3 V 3P 3P V-05SVUL TCL-05SVU3L HL HLF-05SVU Hle lock device 2P HLS-05SVU2 HL-S 3P HLS-05SVU Tripping (The CE CCC characteristics are noted differently. Contact us for more information.) 0 10 NV-CVFU (UL 1053) 0 Operating time Rated ambient temperature Ambient temperature C 4h 2h 1h 30min 10min 4min 2min 1min 10s 5s 2s 50 30s 1s 0.5s 0.2s 0.1s 0.04s 0.02s 0.01s Rated non-operating current Ground fault current (% of rated current sensitivity) 60 Highspeed type Rated current sensitivity Internal Wiring Diagram Line side Magnetic device Leakage indication Test button Sensitivity selector ZCT Load side

161 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button pole (NF-CVFU) Mounting hole Trip button 75 (NV-CVFU) Sensitivity current selector Leakage current indicator button Test button 16 max. f.5 (Conductor thickness t=4 max.) Conductor drilling for direct connection 4 50 f.5 4 M screw f4.5 Compatible crimp terminals Tightening torque 54lb-in (6N m) Applicable wire range Crimp terminal type (*1) 2 mm AWG (#) (60 C/75 C) JST NTM /0 R2- R5.5- R- R14- R22-3-S 60-2BA R2- R5.5- R- R14- R14-S R22-S R3-S CB60-60-S JST: Japan Solderless Terminal Mfg. Co. NTM: Nichifu Co., Ltd. Note *1 When using with a wire connection, use the crimp terminal combination shown above. Front connection(solderless terminal) Mounting hole C Terminal L C L Mounting hole C cover L 210 C L pole 210 C L Terminal cover 4 50 Solderless terminal 90 6 Size of screwdriver with bolting Please bolt with flat head screwdriver. The length of X : 6mm-7mm The length of Y q 9.5mm Y X Flat head screwdriver Wire size 60 C/75 C CU ONLY Number of strs 14AWG AWG 7 AWG 7 6-4AWG 7 2AWG 7 1-1/0AWG 19 The tightening torque is different according to connected wire. Refer to instruction manual for details. Remark: Periodical retightening prevents overheating by the setting of twisted strs or the stress of heating cooling. 2-pole M40.7screw or f5 C L C L C L C L C L 111 C L R1 52 Other 2-pole The drilling dimensions have a 1.0 mm clearance on each side of breaker window frame. Drilling plan Front panel drilling plan

162 22 NF125-SVU NF125-HVU NV125-SVU NV125-HVU NF125-HVU Rated short-circuit breaking capacity (ka) Model NF125-SVU NF125-HVU Model NV125-SVU NV125-HVU Rated current In (A) Rated ambient temperature 40 C (40) (40) Rated current In (A) Rated ambient Number of poles () 75 (0) () 75 (0) temperature 40 C 3f3W 3f3W 3f3W 3f3W (90) (90) Phase line 1f2W 1f2W 1f2W 1f2W Rated UL Number of poles voltage IEC Rated voltage VAC Y/347V 600Y/347V VAC EN UL Y/347V 1 1 Rated current sensitivity 30/50/ 30/50/ 30/50/ 30/50/ /200/500 /200/500 /200/500 /200/500 CSA C V IΔn ma selectable selectable selectable selectable No.5-02 AC 240V Pick-up current UL % of IΔn 75% of IΔn 75% of IΔn 75% of IΔn 120V Operating time (sec) within AT 5lΔn 0.04 (*1) 0.04 (*1) 0.04 (*1) 0.04 (*1) Rated insulation voltage Ui V Earth-leakage indication system Mechanical button Mechanical button Mechanical button Mechanical button 690V /4 /4 10/5 10/5 UL 49 40V V 1/9 1/9 25/13 25/13 CSA C22.2 AC 240V IEC V 30/15 30/15 50/25 50/25 No V EN (Icu/Ics) AC 415V 30/15 30/15 50/25 50/25 440V 30/15 30/15 50/25 50/25 400V 30/15 30/15 50/25 50/25 IEC V 30/15 30/15 50/25 50/25 EN AC 30V 30/15 30/15 50/25 50/25 (Icu/Ics) 230V 50/25 50/25 /50 /50 230V 50/25 50/25 /50 /50 V 50/25 50/25 /50 /50 Stard attached parts (Front connection) Note *1 0.1 for UL1053. High-speed type Rated short-circuit breaking capacity (ka) Mounting screw M (2 screws), Insulating barrier (2P: 2pcs, 3P: 4pcs) Other Operating (The CE CCC characteristics are noted differently. Contact us for more information.) Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. Max. 0.02s Time-delay trip 0.01s Instantaneous trip Current (% of Ir) Operating (UL 49) NF125-SVU NV125-SVU NF125-HVU NV125-HVU 15A-30A Tripping (The CE CCC characteristics are noted differently. Contact us for more information.) NV125-SVU NV125-HVU (UL 1053) Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.04s 0.02s 0.01s Rated non-operating current Highspeed type Rated current sensitivity Ground fault current (% of rated current sensitivity) Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Min. Time-delay trip Operating (UL 49) NF125-SVU NV125-SVU NF125-HVU NV125-HVU 40A-A Current (% of Ir) Max. (60A-A) Max. (40A-50A) Instantaneous trip Internal NF125-SVU NF125-HVU 2-pole Hle of circuit breaker Left pole Right pole Temperature Compensation Curve Rated current compensation rate % Rated ambient temperature Ambient temperature C AL AX Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. Operating (UL 49) NF125-SVU NV125-SVU NF125-HVU NV125-HVU 125A Max. 0.02s Time-delay trip Instantaneous trip 0.01s SHT or UVT TBM NV125-SVU NV125-HVU Current (% of Ir) Outgoing direction of lead wires Internal Wiring Diagram Line side Magnetic device Leakage indication Test button Sensitivity selector ZCT Load side External Type name Type name F F-1SVUL Operating hle Terminal cover Large TC-L TCL-1SVU3 V V-1SVUL Hle lock device HL HLF-05SVU HL-S HLS-05SVU

163 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button (NF125-SVU, NF125-HVU) Insulation barrier (removable) Front connection (solderless terminal) Mounting hole 90 Insulation barrier (removable) Trip button Mounting hole Mounting hole (NV125-SVU, NV125-HVU) Insulation barrier (removable) Insulation barrier (removable) 4 Sensitivity current selector Leakage current indicator button Test button 50 f.5 19 max. (Conductor thickness t=4 max.) Conductor drilling for direct connection 4 50 f.5 4 M screw 65 6 Compatible crimp terminals Tightening torque 54lb-in (6N m) Applicable wire range Crimp terminal type (*1) 2 mm AWG (#) (60 C/75 C) JST NTM /0 R2- R5.5- R- R14- R22-3-S 60-2BA R2- R5.5- R- R14- R14-S R22-S R3-S CB60-60-S JST: Japan Solderless Terminal Mfg. Co. NTM: Nichifu Co., Ltd. Note *1 When using with a wire connection, use the crimp terminal combination shown above f4.5 Wire size Number of strs 60 C/75 C CU ONLY 14AWG a AWG a 7 AWG 7 6AWG 7 4-2AWG 7 1AWG 19 The tightening torque is different according to connected wire. Refer to instruction manual for details. a:solid copper wire is usable. Remark: Periodical retightening prevents overheating by the setting of twisted strs or the stress of heating cooling. 123 R Solderless terminal Hexagon socket set screw 5.03 Other 30 6 Drilling plan M40.7 screw or f5 The drilling dimensions have a 1.0 mm clearance on each side of breaker window frame. Front panel drilling plan Remark: 1. 2-pole models are with the central pole conductor removed.

164 24 NF225-CWU NF225-CWU Operating Model NF225-CWU Rated current In (A) at ambient temperature 40 C (IEC30 C) Number of poles 3 UL 49 Rated voltage (VAC) 240 AC 240V 35 Rated insulation voltage Ui (V) V 10/5 IEC V 15/ AC (Icu/Ics) 400V 1/9 230V 35/1 DC 250V 10/5 (*1) Rated short-circuit breaking capacities (ka) Stard attached parts Mounting screw: M (2pcs), Insulation barrier: (4pcs), Terminal cover: (1 set) (*2) Notes *1 Use either two poles. When wired as shown at the bottom of page 690, the models can be used for up to 400 V DC. *2 The stard configuration contains a protection cover adopts the IP20 (finger protection) structure. 4h 2h 1h 30min 20min 14min 10min Type NF225-CWU Operating time 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s Min. Max. Other Internal Left-side mounting Operating hle Right-side AL mounting External AX 0.2s 0.1s 0.05s 0.02s 0.01s SHT or UVT Time-delay trip % of Rated current Lead wire direction Max. total breaking time Instantaneous trip 40 Temperature Compensation Curve Current rating (%) Rated ambient temperature Ambient temperature ( C) Type name Type name F F-2SUL Operating hle Mechanical interlock Ml MI-05SWU3 V V-2SUL TCL-2SWU3 Hle lock device HL HLF-2SWU Terminal cover Large TC-L TCL-2SWU3L 50 60

165 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button LC LC Insulating barrier M bolt (Hex-soket) 50 f f4.5 f max. Conductor thickness t=7 max. Conductor drilling for direct connection Compatible crimp terminals Tightening torque 90lb-in (10N.m) Applicable wire range Crimp terminal type (*1) 2 AWG (#) mm (60 C/75 C) JST NTM R22- R22- R22-S 22-S CB22-S R3- R3-3-S R3-S R BA CB60-S - 0-3BA CB0-S -3BA /0 CB-S JST: Japan Solderless Terminal Mfg. Co. NTM: Nichifu Co., Ltd. Note 1/0 2/0 3/0 R60- CB60- CB60-S R- *1 When using with a wire connection, use the crimp terminal combination shown above. 92 CL LC R1 CL 126 CL Drilling plan M40.7 screw or f5 Front cover cutout 1mm clearance on each side of hle Other

166 26 NF250-SVU NF250-HVU NV250-SVU NV250-HVU NF250-HVU Rated short-circuit breaking capacity (ka) Model NF250-SVU NF250-HVU Model NV250-SVU NV250-HVU Rated current In (A) Rated ambient temperature 40 C Rated current In (A) Rated ambient Number of poles temperature 40 C ø3W 3ø3W 3ø3W 3ø3W Phase line 1ø2W 1ø2W 1ø2W 1ø2W Rated UL Number of poles voltage IEC Rated voltage VAC Y/347V 600Y/347V VAC EN UL Y/347V 1 1 Rated current sensitivity 30/50/ 30/50/ 30/50/ 30/50/ /200/500 /200/500 /200/500 /200/500 CSA C V IΔn ma selectable selectable selectable selectable No.5-02 AC 240V Pick-up current UL % of IΔn 75% of IΔn 75% of IΔn 75% of IΔn 120V Operating time s within AT 5lΔn 0.04 (*1) 0.04 (*1) 0.04 (*1) 0.04 (*1) Rated insulation voltage Ui V Earth-leakage indication system Mechanical button Mechanical button Mechanical button Mechanical button 690V /4 /4 10/5 10/5 UL 49 40V V 25/13 25/13 36/1 36/1 CSA C22.2 AC 240V IEC V 36/1 36/1 50/25 50/25 No V EN (Icu/Ics) AC 415V 36/1 36/1 50/25 50/25 440V 36/1 36/1 50/25 50/25 400V 36/1 36/1 50/25 50/25 IEC V 36/1 36/1 50/25 50/25 EN AC 30V 36/1 36/1 50/25 50/25 (Icu/Ics) 230V 65/33 65/33 /50 /50 230V 65/33 65/33 /50 /50 V 65/33 65/33 /50 /50 Stard attached parts (Front connection) Note *1 0.1 for UL1053. High-speed type Rated short-circuit breaking capacity (ka) Mounting screw M (2 screws), Insulating barrier (4pcs) 250 Other Operating (The CE CCC characteristics are noted differently. Contact us for more information.) 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s Operating time 2s 1s 0.5s 0.2s 0.1s 0.05s Internal NF250-SVU NF250-HVU Hle of circuit breaker Left pole Min. Right pole AL Operating (UL 49) NF250-SVU NV250-SVU NF250-HVU NV250-HVU AX Max A 0.02s 0.01s Time-delay trip Instantaneous trip Current (% of Ir) SHT or UVT TBM Max. total breaking time NV250-SVU NV250-HVU External 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s Operating time 2s 1s 0.5s 0.2s 0.1s 0.05s Outgoing direction of lead wires Min. Temperature Compensation Curve Rated current compensation rate % Operating (UL 49) NF250-SVU NV250-SVU NF250-HVU NV250-HVU Max. 250A 0.02s 0.01s Time-delay trip Instantaneous trip Current (% of Ir) Max. total breaking time Rated ambient temperature Ambient temperature C Tripping (The CE CCC characteristics are noted differently. Contact us for more information.) NV250-SVU NV250-HVU (UL 1053) Internal Wiring Diagram Line side Magnetic device Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.04s 0.02s 0.01s Rated non-operating current Ground fault current (% of rated current sensitivity) Leakage indication Type name Type name Operating hle F F-2SVUL TCL-2SVU3 Terminal cover Large TC-L V V-2SVUL TCL-2SVU3L Hle lock device HL HLF-05SVU HL-S HLS-2SVU Highspeed type Rated current sensitivity Test button Sensitivity selector ZCT Load side

167 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mounting hole Trip button Insulation barrier (removable) 144 (NF250-SVU, NF250-HVU) Trip button Mounting hole Insulation barrier (removable) (NV250-SVU, NV250-HVU) Sensitivity current selector Leakage current indicator button Test button 102 Hexagon socket M bolt 50 f f4.5 C1 Max. 25 Compatible crimp terminals Applicable wire range Crimp terminal type (*2) 2 AWG (#) mm (60 C/75 C) /0 Tightening torque 90lb-in (10N.m) JST R22-22-S R3-3-S R BA CB60-S NTM R22- R22-S CB22-S R3- R3-S R60- CB60- CB60-S /0 - R /0 0-3BA CB0-S /0-3BA CB-S /300MCM CB150-S (*1) JST: Japan Solderless Terminal Mfg. Co. NTM: Nichifu Co., Ltd. Notes *1 TCL-2SVU3L can be mounted when using CB150-S. *2 When using with a wire connection, use the crimp terminal combination shown above. f.5 10 C1 or (Conductor thickness t=7 max.) Conductor drilling for direct connection f.5 9 Max. 25 Front connection (solderless terminal) Mounting hole Terminal cover Mounting hole Solderless terminal Terminal cover Hexagon socket set screw C L C L Wire size 60 C/75 C CU ONLY Number of strs 4-2AWG 7 1-1/0AWG 19 3/0-4/0AWG MCM 37 The tightening torque is different according to connected wire. Refer to instruction manual for details. Remark: Periodical retightening prevents overheating by the setting of twisted strs or the stress of heating cooling. R1 C L 126 C L Other M40.7screw or f5 The drilling dimensions have a 1.0 mm clearance on each side of breaker window frame. Drilling plan Front panel drilling plan

168 2 NF400-SWU NF400-HWU NF400-SWU Operating Model NF400-SWU NF400-HWU Rated current In (A) at ambient temperature 40 C Number of poles 3 3 UL 49 Rated voltage (VAC) 600Y/ Y/ Y/347V CSA C22 2 AC 40V No V 65 Rated insulation voltage Ui (V) V 10/10 (5/5) (*1) 15/10 IEC V 30/30 (25/25) (*1) 42/42 EN (Icu/Ics) AC 440V 42/42 (36/36) (*1) 65/65 400V 45/45 (36/36) (*1) / 230V 5/5 (65/65) (*1) / Rated short-circuit breaking capacities (ka) Stard attached parts Notes *1 In case of solderless terminal, interrupting capacity reduces: (/). *2 0.1 for UL1053. Mounting screw: M6360 (4screws) Mounting screw: M6360 (4screws) Insulating plate (1pce) Insulating plate (1pce) Insulating barrier (4pcs) Insulating barrier (4pcs) (Only for type with bar terminals) (Only for type with bar terminals) 4h 4h 2h 1h 30min 20min 14min 10min 6min 4min Operating (UL 49) NF400-SWU NF400-HWU 2h 1h 30min 20min 14min 10min 6min 4min Operating (IEC ) (EN ) NF400-SWU NF400-HWU Operating time 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. Max. Max.total interrupting time Operating time 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. Max. Max.total interrupting time Other Internal Left-side mounting Operating hle Right-side AL mounting NF400-SWU, NF400-HWU 0.02s Time-delay trip Instantaneous trip 0.01s % of rated current (*1) (*1) AX SHT or UVT (*1) (*1) Lead wire direction Note *1 Right-side mounting is stard of SHT UVT. Specify separataly for left-side mounting. External 0.02s Time-delay trip Instantaneous trip 0.01s % of rated current Temperature Compensation Curve Current rating (%) Rated ambient temperature Ambient temperature ( C) Type name Type name F F-4SUL Operating hle Terminal cover Large TC-L TCL-4SWU V V-4SUL Hle lock device HL HL-4SWU 50 60

169 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection (Solderless terminal) Mounting hole Trip button (max.141) (NF400-SWU) Remarks: 1. Do not remove solderless terminal in any case. 2. When using the solderless terminals, conduct periodic inspections tightening as the wires may wear down over use f12.5 Solderless terminal 155 f Hexagon socket set screw Tightening torque 275lb-in. (31.1N m) UL Ampere ratings Wire size Number of strs 250A, 300A kcmil CU A 350A, 400A 350kcmil AL (2) 3/0AWG CU 19 IEC Wire size (IEC 6022) Ampere ratings Class 2 Class 5 250A, 300A -15mm mm2 350A, 400A mm mm 2 3. Use a wire size that can carry the rated current. 4. When using IEC Class 5 (multi-core wire), pay attention to str breakage pinching, etc., while tightening. 5. The NF400-HWU does not have a solderless terminal. Front connection (Busbar terminal) Insulating barrier (removable) Mounting hole Conductor thickness t=10 max Trip button f12.5 f (max.141) f13 M12 bolt Remark: Do not remove busbar terminal in any case. (NF400-SWU) (NF400-HWU) 155 R6 CAUTION When mounted in steel or cast box cover must be insulated as shown. 5mm air gap to cover or 0.mm fibre insulating plate extending 12.7mm out from each side of breaker f7 holes 11 or M6 taps 1mm clearance on each side of hle. Insulating plate Other Drilling plan Front-panel cutout (Line)

170 30 NF630-SWU NF630-HWU NF630-SWU Operating Model NF630-SWU NF630-HWU Rated current In (A) at ambient temperature 40 C Number of poles 3 3 UL 49 Rated voltage (VAC) 600Y/ Y/ Y/347V CSA C22.2 AC 40V No V 5 Rated insulation voltage Ui (V) V 10/10 15/10 IEC V 30/30 42/42 EN (Icu/Ics) AC 440V 42/42 65/65 400V 45/45 / 230V 5/5 / Rated short-circuit breaking capacities (ka) Stard attached parts Mounting screw: M6335 (4pcs) Mounting screw: M6335 (4pcs) Insulating plate (1pce) Insulating plate (1pce) Insulating barrier Insulating barrier (500A,600A: 2pcs, 630A: 4pcs) (500A,600A: 2pcs, 630A: 4pcs) (Only for type with bar terminals) (Only for type with bar terminals) 4h 4h Other Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Min. Time-delay trip Internal Left-side mounting Operating hle Right-side mounting Max. Operating (UL 49) NF630-SWU NF630-HWU Inst. trip adjustment range (4 steps) Control setting % of rated current AL AX Lo 2 3 Hi Inst. trip current (%) 400±0 600±120 00±160 0±200 Adjustable range of inst. pick up current Max. total interrupting time Instantaneous trip SHT or UVT (*1) (*1) (*1) (*1) Lead wire direction Note *1 Right-side mounting is stard of SHT UVT. Specify separataly for left-side mounting. External Operating time 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s Min. Max. Operating (IEC ) NF630-SWU NF630-HWU Inst. trip adjustment range (4 steps) Control setting Lo 2 3 Hi Inst. trip current (%) 400±0 600±120 00±160 0±200 Adjustable range of inst. pick up current 0.2s Max. total 0.1s interrupting time 0.05s 0.02s Time-delay trip Instantaneous trip 0.01s % of rated current Temperature Compensation Curve Current rating (%) Rated ambient temperature Ambient temperature ( C) Type name Type name F F-6SUL Operating hle Terminal cover Large TC-L TCL-6SWU V V-6SUL Hle lock device HL HL-4SWU 50 60

171 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection (Solderless terminal) Mounting hole Trip button Remarks: 1. Do not remove solderless terminal in any case. 2. When using the solderless terminals, conduct periodic inspections tightening as the wires may wear down over use f Solderless terminal f 15 UL Ampere ratings 500A, 600A Hexagon socket set screw Wire size (2) kcmil CU ONLY Tightening torque 275lb-in. (31.1N m) IEC Wire size (IEC 6022) Ampere ratings Class 2 Class 5 500A, 600A (2) 95-15mm 2 (2) mm 2 Number of strs 3. Use a wire size that can carry the rated current. 4. When using IEC Class 5 (multi-core wire), pay attention to str breakage pinching, etc., while tightening. 5. The 630A NF630-HWU does not have a solderless terminal. 37 Front connection (Busbar terminal) 630A: A, 600A:110 Insulating barrier (removable) Conductor thickness t=12 max Mounting hole Remark: Do not remove busbar terminal in any case. Trip button 630A: f14 M12 bolt 5 f f R6 CAUTION When mounted in steel or cast box cover must be insulated as shown. 5mm air gap to cover or 0.mm fibre insulating plate extending 12.7mm out from each side of breaker f7 holes or M6 taps 172 1mm clearance on each side of hle. Insulating plate Other Drilling plan Front-panel cutout (Line)

172 32 NF250-SEV with MDU NF250-HEV with MDU NF250-SEV with MDU ( mounting) NF250-SEV with MDU (Panel mounting) Operating Model NF250-SEV with MDU NF250-HEV with MDU Rated current In (A) Rated ambient temperature 40 C Current setting Ir (A) Number of poles Rated insulation voltage Ui (V) Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts (Front connection) mounting MDU accessories Panel mounting 690V / 10/ 500V 1/1 30/23 440V 36/36 50/50 AC 415V 36/36 / 400V 36/36 75/75 30V 36/36 75/75 230V 5/5 / DC 250V Mounting screw M (3P: 2psc, 4P: 4pcs) Insulation barrier (3P: 4pcs, 4P: 6pcs) MDU, cable (for breaker mounting) MDU, Panel mounting bracket, Panel mounting screw, cable (for panel mounting) Other Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s I 6 t ON 60 I 6 t OFF I 2 t ON I 2 t OFF LTD operating time at 125%(I 6 t ON) 6s (TL = s set) 540s (TL = 0s set) 400s (TL = 60s set) 0s (TL = 12s set) Internal Left-side mounting Operating hle Right-side mounting INST pickup current Ii In 2-14 ±15%, Ir 14 ±15% Operating characteristics NF250-SEV with MDU NF250-HEV with MDU Note) Current setting Ir (Adjustable) Rated current In 250A LTD operating time TL 12600s ±20% (at 200%) STD pickup current Is Ir ( ) ±15% STD operating time Ts 0.3±0.06s 0.2±0.04s 0.1±0.03s Max. total breaking time Current (% of Ir) Instantaneous tripping current (% of In, or % of Ir) AL AX SHT or UVT Note *1 SLT-equipped is stard. Control voltage (-240VAC/-240VDC) is necessary. External PAL Lead-wire direction AL for MDU transmission (*1) AX for MDU transmission Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s I 6 t ON 60 I 6 t OFF I 2 t ON I 2 t OFF LTD operating time at 125%(I 6 t ON) 6s (TL = s set) 540s (TL = 0s set) 400s (TL = 60s set) 0s (TL = 12s set) INST pickup current Ii In 2-14 ±15%, Ir 14 ±15% Operating characteristics NV250-SEV with MDU NV250-HEV with MDU Note) Current setting Ir (Adjustable) Rated current In 250A LTD operating time TL 12600s ±20% (at 200%) STD pickup current Is Ir ( ) ±15% STD operating time Ts 0.3±0.06s 0.2±0.04s 0.1±0.03s Max. total breaking time Current (% of Ir) Instantaneous tripping current (% of In, or % of Ir) Current Reducing Curve Derating of Load current (%) Rated ambient temperature The rated current does not have thermal characteristics. Reduce the current as shown in the curve on the left chart if the ambient temperature exceeds 40 C Ambient temperature ( C) Type name Type name F F-2SV 3P MI-05SV3 Operating hle (*1) Mechanical interlock MI (*3) V V-2SV 4P MI-2SV4 LC LC-05SV Small TC-S 3P TCS-2SV3 (*5) HLF-05SV TCL-2SV3 (*5) Hle lock device HL (*2) 3P HLN-05SV Terminal Large TC-L TCL-2SV3L (*5) HL-S (*1) HLS-2SV cover 4P TCL-2SV4 Notes *1 Available only for the MDU panel mounting type. *2 HLF types are used for OFF lock HLN types for ON lock. *3 When selecting the MDU breaker mounting, only the MI panel mounting can be manufactured. *4 Specify the working voltage. *5 In the case of the MDU breaker mounting type, specify the model name with MP at the end. Skeleton TTC 3P TTC-2SV3 (*5) Rear BTC 3P BTC-2SV3 (*5) Electrical operation device (*1) (*4)

173 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Mtg hole Trip button MDU unit MDU breaker mounting Rear mounting Mtg plate t max.=3.2 MDU unit M4 0.7 breaker mtg screw Insulation tube MDU breaker mounting Insulation barrier (removable) Mtg plate t max.=3.2 Insulation tube allowance allowance Insulation barrier (removable) Insulation tube Stud can be rotated f9 M bolt A M bolt (Hex-soket) Neutral pole f.5 MDU specification No transmission, pulse output CC-Link (65) R1 A f Front-plate cut out Mtg hole Trip button B 77.5 B MDU specification B No transmission, pulse output 16 CC-Link MDU panel mounting 15 f9 M bolt M bolt (Hex-soket) MDU panel mounting MDU unit terminal for breaker mounting MDU panel mounting MDU terminal for panel mounting Stud can be rotated Neutral pole 105 f M4 0.7 breaker mtg screw Insulation tube f4.5 C1 R1 or (Bus t max.=7) f.5 Front-plate cut out 25 max. f C1 25 max. Bus drilling for direct connection 1mm clearance on each side of hle M4 0.7 taps or f5 35 Drilling plan f24 M4 0.7 taps or f Drilling plan This figure is without terminal cover. Please bind wires. Control power FG Control power MB Panel note: Panel t 1.0mm - 3.2mm Operation indication side 90 This figure is without terminal cover. Please bind wires. Control power MA MA, MB,FG M3 screw Removable connector MDU specification 1 No transmission Pulse output CC-Link Cb Ca SLD DG DB DA MDU connector Panel holder plate R2 72 Front-panel cut out Terminal block MAMB Control power MDU specification No transmission FG 6 Pulse output Ca Cb FG CC-Link DA DB DG SLD FG Other

174 34 NF400-SEP with MDU NF400-HEP with MDU NF400-SEP with MDU ( mounting) Model NF400-SEP with MDU NF400-HEP with MDU Rated current In (A) Adjustable Rated ambient temperature 40 C Number of poles Rated operational voltage Ue V Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts (Front connection) MDU accessories 690V 10/10 10/10 500V 30/30 50/50 440V 42/42 65/65 AC 415V 45/45 / 400V 45/45 / 30V 45/45 / 230V 5/5 / 200V 5/5 / Mounting screw M6 60 (4pcs) Insulation barrier (3P: 4pcs, 4P: 6pcs) mounting MDU, cable (for breaker mounting) Panel mounting MDU, Panel mounting bracket, Panel mounting screw, cable (for panel mounting) Operating Internal Other Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip Ir x( ±10% ) Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) 60 LTD operating time at 130% 790s (TL = 150s set) 530s (TL = s set) 315s (TL = 60s set) 65s (TL = 12s set) INST pickup current II x4-x16 ±15% (Magnification to In) Operating characteristics NF400-SEP with MDU NF400-HEP with MDU (Magnification to In) Note) Current setting Rated Current Ir: A In: 400A (Adjustable) LTD operating time TL s ±20% (at 200%) STD pickup current Is Ir ( ) ±15% STD operating time Ts 0.3±0.06s 0.2±0.04s 0.1±0.03s 0.06±0.02s Max. total breaking time Current (% of Ir) Instantaneous tripping current (% of In) External Current Reducing Curve Derating of Load current (%) (*1) (*1) Rated ambient temperature Ambient temperature ( C) (*1) (*1) Left-side mounting AL AL for MDU transmission AX for MDU transmission SHT or UVT MG TBM Operating hle Right-side mounting AX EAL PAL TI EPAL Lead-wire direction Note *1 Right side mounting is stard of SHT UVT. Specify separately for left side mounting. TBL ATU The rated current does not have thermal characteristics. Reduce the current as shown in the curve on the left chart if the ambient temperature exceeds 40 C. Type name Type name mounting Panel mounting mounting Panel mounting Operating hle F F-4S 3P TCL-4SW3 (*1) Large TC-L V V-4S 4P TCL-4SW4 (*1) Hle lock device HL HL-4SW HL-4SW 3P TTC-4SW3-MDU TTC-4SW3 Skeleton TTC HL-S HLS-4SW Terminal 4P TTC-4SW4-MDU TTC-4SW4 3P MI-4SW3 MI-4SW3 cover BTC-4SW3 (*1) Mechanical interlock MI (*2) 3P BTC-4SW3 (*4) 4P MI-4SW4 MI-4SW4 Only line side Rear BTC Auxiliary hle HT HT-4SW HT-4SW BTC-4SW4 4P BTC-4SW4 Notes *1 For NF400SEP with MDU. Only line side *2 When selecting the MDU breaker mounting, only the MI panel mounting 3P can be manufactured. Electrical operation device NFM *3 Specify the operation method voltage. Order in combination with the 4P (*3) breaker unit. *4 This is for NF400-SEP with MDU. For rear terminal cover of NF400-HEP with MDU, use PTC-4SW3.

175 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection PE Rear connection 110 Trip button f14 M12 bolt MDU terminal cover Mounting plate Stud can be rotated 90 Insulating barrier (removable) Mounting hole Current indication LED OVER PAL MDU % 22 MDU Neutral pole Conductor t max.= Eddy-current heat-reducing slit f f M6 taps 44 or f7 25 f10.5 Conductor t max.= Drilling plan Conductor drilling for direct connection Front-plate cutout 194 1mm clearance on each side of hle. (Load side of breaker mounting has given the space to pass wires to the terminal.) 113 allowance f13 M12 bolt Note The drilling plan is different if insulating barriers are installed. M6 taps or f7 14 M6 breaker mounting screw Insulating tube f Drilling plan R (59) < mounting> <Panel mounting> CC-Link ; only MDU panel mounting R6 NF400-SEP, NF400-HEP with MDU (No transmission, pulse output) MDU is connected with circuit breaker via MDU connection cable. MDU panel mounting M4 screw Panel holder plate Terminal PE screw (M4) M3 nut Upper Terminal block MDU connector 40 side M4 screw Panel 96 M3.5 screw Terminal cover M3 nut Front panel cutout NF400-SEP, NF400-HEP with MDU (CC-Link) MDU panel mounting Upper side Operation/display side Operation/display side M3 screw 3 Terminal PE screw(m4) 75 Panel 4 M3 screw R Type NF400-SEP NF400-HEP Space greater than the value shown in the figure below must be secured, must be separate 10cm or more from the distribution line. MDU is connected with circuit breaker via MDU connection cable. Panel holder plate MDU connector M3 nut Panel thickness 1-3.2mm MDU display part Panel thickness 1-3.2mm MDU display part R For the set installation A B Front panel cutout A B In case of front connection, keep space between MDU conductor or insulation barrier. Space greater than the value shown in the figure below must be secured, must be separate 10cm or more from the distribution line. For the set installation A B MDU terminal <Panel mounting> < mounting> MDU terminal <Panel mounting> < mounting> Terminal block Figure of the breaker mounting is removed the terminal cover L2 L1 Control power No transmission Pulse output L1L Control power No transmission Pulse output FG FG Figure of the breaker mounting is removed the terminal cover L2 L SLD DG DB DA SLD DG DB DA Control power Other 43.1 Terminal block Terminal cover M3 screw M3 nut Type NF400-SEP NF400-HEP A B In case of front connection, keep space between MDU conductor or insulation barrier. Terminal block Control power L1L FG SLD DG DB DA

176 36 NF630-SEP with MDU NF630-HEP with MDU NF00-SEP with MDU NF00-HEP with MDU NF630-SEP with MDU ( mounting) Model NF630-SEP with MDU NF630-HEP with MDU NF00-SEP with MDU NF00-HEP with MDU Rated current In (A) Rated ambient temperature 40 C Adjustable Adjustable Number of poles Rated operational voltage Ue V Rated short-circuit breaking capacity (ka) IEC (Icu/Ics) Stard attached parts (Front connection) (*1) 690V 10/10 15/15 10/10 15/15 500V 30/30 50/50 30/30 50/50 440V 42/42 65/65 42/42 65/65 AC 415V 45/45 / 45/45 / 400V 45/45 / 45/45 / 30V 45/45 / 45/45 / 230V 5/5 / 5/5 / 200V 5/5 / 5/5 / Mounting screw M6 35 (4pcs) Insulation barrier (3P: 2pcs, 4P: 3pcs) MDU, mounting plate, Mounting screw for breaker mounting plate, mounting cable (for breaker mounting), MDU Mounting screw MDU accessories Panel MDU, Panel mounting bracket, Panel mounting nut, cable (for mounting panel mounting), MDU Mounting screw Note *1 models are provided with auxiliary hle. Other Operating Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip Ir x( ±10% ) Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) 60 INST pickup current II x4-x15 ±15% (Magnification to In) LTD operating time at 130% 790s (TL = 150s set) 530s (TL = s set) 315s (TL = 60s set) 65s (TL = 12s set) Internal External Operating characteristics NF630-SEP with MDU NF630-HEP with MDU (Magnification to In) Note) Current setting Rated Current Ir: A In: 630A (Adjustable) LTD operating time TL s ±20% (at 200%) STD pickup current Is Ir ( ) ±15% STD operating time Ts 0.3±0.06s 0.2±0.04s 0.1±0.03s 0.06±0.02s Max. total breaking time Current (% of Ir) Instantaneous tripping current (% of In) (*1) (*1) (*1) (*1) Left-side mounting AL AL for MDU transmission AX for MDU transmission SHT or UVT MG TBM Operating hle Right-side mounting AX EAL PAL TI EPAL Lead-wire direction Note *1 Right side mounting is stard of SHT UVT. Specify separately for left side mounting. TBL ATU Operating time 10h 5h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s Pre-alarm pickup current Ip Ir x( ±10% ) Pre-alarm operating time Tp TL Tp= ±20% 2 (at 200%) 60 INST pickup current II x4-x12 ±15% (Magnification to In) LTD operating time at 130% 790s (TL = 150s set) 530s (TL = s set) 315s (TL = 60s set) 65s (TL = 12s set) Operating characteristics NF00-SEP with MDU NF00-HEP with MDU (Magnification to In) Note) Current setting Rated Current Ir: A In: 00A (Adjustable) LTD operating time TL s ±20% (at 200%) STD pickup current Is Ir ( ) ±15% STD operating time Ts 0.3±0.06s 0.2±0.04s 0.1±0.03s 0.06±0.02s Max. total breaking time Current (% of Ir) Instantaneous tripping current (% of In) Current Reducing Curve Type name Type name mounting Panel mounting mounting Panel mounting Operating hle F F-S 3P TCL-SW3 Large TC-L V V-S 4P TCL-SW4 Hle lock device HL HL-4SW HL-4SW 3P TTC-SW3-MDU TTC-SW3 Skeleton TTC HL-S HLS-SW Terminal 4P TTC-SW4-MDU TTC-SW4 MI 3P MI-SW3 MI-SW3 cover BTC-SW3 Mechanical interlock 3P BTC-SW3 (*1) 4P MI-SW4 MI-SW4 Only line side Rear BTC Auxiliary hle HT HT-4SW HT-4SW BTC-SW4 4P BTC-SW4 Notes *1 When selecting the MDU breaker mounting, only the MI panel mounting Only line side can be manufactured. 3P *2 Specify the operation method voltage. Order in combination with the Electrical operation device NFM breaker unit. 4P (*2) Derating of Load current (%) Rated ambient temperature Ambient temperature ( C) The rated current does not have thermal characteristics. Reduce the current as shown in the curve on the left chart if the ambient temperature exceeds 40 C.

177 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing Front connection Rear connection ø13 M12 bolt 140 Note The drilling plan is different if insulating barriers are installed. M6 taps or ø7 MDU NF630-SEP, NF630-HEP, NF00-SEP, NF00-HEP with MDU (No transmission, Pulse output) MDU is connected with circuit breaker via MDU connection cable. MDU panel mounting MDU terminal M4 screw Panel holder plate Terminal PE screw (M4) M3 nut Upper Terminal block MDU connector 40 side Space greater than the value shown in the figure below must be secured, must be separate 10cm or more from the distribution line. NF630-SEP, NF630-HEP, NF00-SEP, NF00-HEP with MDU (CC-Link) MDU is connected with circuit breaker via MDU connection cable. MDU panel mounting MDU terminal Upper side M4 screw Mounting plate Operation/display side Operation/display side 2.5 allowance M3 screw 3 Terminal PE screw(m4) Trip button PE Panel 96 M3.5 screw Panel 4 M3 screw Terminal cover 5 90 Stud can be rotated 90 Panel holder plate MDU connector Insulating barrier (removable) M3 nut Mounting hole Current indication LED OVER PAL MDU % MDU terminal cover Panel thickness 1-3.2mm M3 nut MDU display part M6 breaker mounting screw 75 R R Type NF630-SEP NF00-SEP NF630-HEP NF00-HEP Front panel cutout Panel thickness 1-3.2mm MDU display part A ø4 B Front panel cutout Conductor t max AF AF t 00AF 46 00AF t Neutral pole f14 M12 bolt Eddy-current heat-reducing slit 210 Drilling plan For the set installation A B Space greater than the value shown in the figure below must be secured, must be separate 10cm or more from the distribution line. For the set installation A B 30 In case of front connection, keep space between MDU conductor or insulation barrier f f AF 44 00AF 46 Dimension of terminal directly connected to conductor f.5 40 Front-plate cutout R Conductor t max. 600AF t 00AF t10 6 (6) < mounting> 1mm clearance on each side of hle. (Load side of breaker mounting has given the space to pass wires to the terminal.) CC-Link ; only MDU panel mounting <Panel mounting> < mounting> <Panel mounting> 600AF 24 00AF 26 Conductor drilling for direct connection < mounting> No transmission Terminal block R <Panel mounting> 92 Figure of the breaker mounting is removed the terminal cover. L1L Control power L2 L1 Figure of the breaker mounting is removed the terminal cover L2 L SLD DG DB DA SLD DG DB DA Control power Pulse output No transmission Pulse output M6 taps or f7 Drilling plan FG FG Control power Other 43.1 Terminal block Terminal cover M3 screw M3 nut Type NF630-SEP NF00-SEP NF630-HEP NF00-HEP A B In case of front connection, keep space between MDU conductor or insulation barrier. Terminal block Control power 1 L1L FG SLD DG DB DA

178 3 Miniature BH BH-P Operating time 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s BH Min. BH-P Operating Max. Operating Type:BH, BH-P Rated Current:, A Amb. temp.:40 C Model BH BH-P Number of poles Rated current (A) at ambient temperature 40 C,,,, Rated voltage (V) AC 230/ /400 DC Rated short circuit capacity (ka) IEC AC230/400V 3 3 AC400V 3 3 DC125V 1 1 Temperature Compensation Curve Current rating (%) , A Ambient temperature ( C) 1s Other Outline Drawing center BH 0.05s 0.02s 0.01s s 0.2s 0.1s % of rated current Mtg bracket M5 0. screw (line side load side) Mtg hole f Conductor thickness t=4 max BH-P f5.5 6 Rated ambient temperature M5 0. screw Plug-in terminal (line side) Mtg slot pole 2-pole 13.5 Conductor drilling 4.5 Note Two mounting brackets are used for single-pole breakers. four for 2-pole breakers. 1-pole 2-pole 14

179 Low-Voltage Circuit P.664 Magnetic Contactor Starters P BH-D6 BH-D10 BH-D6 Model BH-D6 BH-D10 Number of poles (P) (3+N) (*1) 2(1+N) (*1) (3+N) (*1) BH-D10 (For DC) 1 2 Instantaneous tripping Type B, C, D Type B, C Type B, C, D Type B, C Rated insulation voltage Ui (V) Rated current In (A) at ambient temperature 30 C Rated shortcircuit capacity (ka) IEC609-1 GB (Icn) Operating 0.5, 1, 1.6, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, , 1, 1.6, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, , 1, 1.6, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, , 1, 1.6, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63 AC 230V /400V V IEC609-2 DC 125V 10 GB (Icn) 250V 10 Note *1 N pole is a switched neutral pole (without overcurrent release device). Operating time 4h 2h 1h 30min 20min 10min 5min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. B Operating Type : BH-D6,BH-10(Type B,C) Rated current : AC 0.5A-63A Amb.temp. : 30 C Max. C Operating time 4h 2h 1h 30min 20min 10min 5min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. Operating Type : BH-D6,BH-D10(Type D) Rated current : AC 0.5A-63A Amb.temp. : 30 C (0.5A-4A) Max.(13A-63A) Max.(6A-10A) Operating time 4h 2h 1h 30min 20min 10min 5min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. Operating Type : BH-D10(Type B,C) Rated current : DC 0.5A-63A Amb.temp. : 30 C Max. B C 0.02s 0.01s % of rated current 0.02s 0.01s % of rated current 0.02s 0.01s % of rated current Outline Drawing M5 screw Neutral pole (1+N only) Neutral pole max. Solderless terminal Temperature Compensation Curve Current ratings (%) Ambient compensation Rated ambient temp P 2P 3P 4P Ambient temperature ( C) Other

180 40 Miniature Residual Current BH-DN BH-DN Operating Model BH-DN Number of poles (P) 2 (1+N) (*1) Instantaneous tripping Type C Rated insulation voltage Ui (V) 230 Rated current In (A) at ambient temperature 30 C Rated shortcircuit capacity (ka) IEC609-1 GB (Icn) 6, 10, 16, 20 AC 230V 4.5 Note *1 N pole is a switched neutral pole (without overcurrent release device). 4h 2h 1h 30min 20min 10min 6min 4min Operating Type : BH-DN Rated current : 6A-20A Amb.temp.:30 C 2min Operating time 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s Min. Max. 0.05s Other Outline Drawing max N M4 screw N s 0.01s Solderless terminal % of rated current Temperature Compensation Curve Current ratings (%) Ambient compensation Rated ambient temp Ambient temperature ( C)

181 Low-Voltage Circuit P.664 Magnetic Contactor Starters P BV-D BV-D Operating Model BV-D Number of poles (P) 2 (1+N) (*1) 4 (3+N) (*1) (*2) Rated operational voltage Ue (VAC) /400 Rated current In (A) at ambient temperature 30 C 25, 40, 63 Rated current sensitivity IΔn (ma) 30, 300 Max. operating time at 5IΔn (s) 0.04 Pulsating current sensitivity Type AC Residual operation Dependent on line voltage Rated making breaking capacity Im (A) 500 (In 25, 40A) 630 (In63A) Rated conditional short-circuit current Inc (ka) 6 Rated residual making breaking capacity IΔm (A) 500 (In 25, 40A) 630 (In63A) Rated conditional residual short-circuit current IΔc (ka) 6 Notes *1 N pole is a switched neutral pole (without overcurrent release device). *2 For use to three phase 4-wire type. When using, it be sure to connect the neutral wire to the neutral phase. Not available for use to three phase 3-wire type. Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.04s Rated non-operating current Rated current sensitivity 0.02s 0.01s Ground-fault current (% of rated current sensitivity) Outline Drawing M5 screw Test button Residual indicator max P 4P Solderless terminal Other

182 42 Residual Current with Overcurrent Protection Isolating Switches BV-DN BV-DN Operating Model BV-DN Number of poles (P) 2 (1+N) (*1) Rated operational voltage Ue (VAC) 230 Rated current In (A) at ambient temperature 30 C 6, 10, 16, 20, 25, 32, 40 Instantaneous tripping Type C Rated current sensitivity IΔn (ma) 30,, 300 Max. operating time at 5IΔn (s) 0.04 Pulsating current sensitivity Type AC Residual operation Dependent on line voltage Rated short-circuit capacity (ka) IEC69-1 GB (Icn) AC 230V 4.5 Note *1 N pole is a switched neutral pole (without overcurrent release device). Operating time 4h 2h 1h 30min 20min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.05s Min. Max. Operating Type : BV-DN Rated current : 6A-40A Amb.temp.:30 C Operating time 4h 2h 1h 30min 10min 4min 2min 1min 30s 10s 5s 2s 1s 0.5s 0.2s 0.1s 0.04s Rated non-operating current Rated current sensitivity Other Outline Drawing max N M4 screw Test button s 0.01s Residual indicator N % of rated current 45 Solderless terminal Temperature Compensation Curve Current ratings (%) s 0.01s Ground-fault current (% of rated current sensitivity) Rated ambient temp Ambient temperature ( C)

183 Low-Voltage Circuit P.664 Magnetic Contactor Starters P KB-D KB-D Outline Drawing Model KB-D Number of poles (P) (3+N) (*1) Utilization category AC22A class Rated insulation voltage Ui (V) Rated voltage Ue (VAC) Rated current In (A) at ambient temperature 30 C 32, 63, 0 Short-time withst current (A) 203In, 1sec Short-time making current (A) 203In Note *1 N pole is a switched neutral pole (without overcurrent release device). M5 screw Neutral pole max. 72 1P 2P 3P 4P Solderless terminal Other

184 44 Circuit Protectors / Electrical Operated CP30-BA Operating time 2h 1h 40min 20min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s Instantaneous type (I) Fast type (F) Medium type (M) Slow type (S) AC DC CP30-BA Operating Operating time 2h 1h 40min 20min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s DC AC Frame (A) 30 Model CP30-BA Number of poles Rated impulse withst voltage Uimp (kv) 2.5 Rated current (A) 0.1, 0.25, 0.3, 0.5, 1, 2, 3, 5, 7, 10,15, 20, 30 AC (V) 250 UL 1077 Rated voltage (V) DC (V) CSA C22.2 No.235 AC 2.5kA at 250V DC 2.5kA at 65V 2.5kA at 125V Rated Rated insulation voltage Ui (V) 250 short-circuit IEC capacity (ka) AC 2.5kA at 230V EN DC 2.5kA at 60V 2.5kA at 120V EN Rated insulation voltage Ui (V) 250 IEC AC 2.5/2.5kA at 230V (Icu/Ics) DC 2.5/2.5kA at 60V 2.5/2.5kA at 120V AC-DC common use Instantaneous type (I) Operating characteristics Medium type (M),(MD) Slow type (S),(SD) Fast type (F) Mode of tripping Instantaneous type (I): magnetic only Other type (M, MD, S, SD, F):hydraulic-magnetic 0.2s 0.2s 0.2s 0.1s 0.1s 0.1s 0.05s 0.05s 0.05s 0.02s 0.02s 0.02s 0.01s 0.01s 0.01s Operating time 2h 1h 40min 20min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s DC AC Operating time 2h 1h 40min 20min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s DC AC 0.2s 0.1s 0.05s 0.02s 0.01s Other Current (% of rated current) Outline Drawing CP30-BA ON ON ON AXc AXb 12 AXa 14 Terminal cover Mounting dimension AXb 12 AXc 11 AXa 14 Terminal cover 1-pole 2-pole AXc 11 AXb 12 AXa 14 Current (% of rated current) Terminal cover 5 73 Mounting hole ø Terminal cover IEC 35mm rail 56 ( 3 ) 63 Terminal block of internal accessaries (AL, AX, SHT) Alarm or auxiliary switch terminal M3.5 (Plus minus self-up screw) (The figure shows auxiliary switch. Example: Auxiliary switch) Main terminal (Plus minus self-up screw) M4 20A max. M5 20A over 3 Current (% of rated current) Operating time 2h 1h 40min 20min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s Medium type with inertial delay (MD) 0.2s 0.1s 0.05s 0.02s 0.01s Current (% of rated current) Operating time 2h 1h 40min 20min 10min 6min 4min 2min 1min 30s 20s 10s 5s 2s 1s 0.5s Current (% of rated current) Slow type with inertial delay (SD) 0.2s 0.1s 0.05s 0.02s 0.01s Current (% of rated current) Temperature Curve Operating time variation (%) Rated ambient temperature pole 2-pole 2-M tap 2-M tap 2-M4 tap Tightening torque (N m) Ambient temperature ( C)

185 Low-Voltage Circuit P.664 Magnetic Contactor Starters P (1) of electrical operated circuit breakers The following concept is applied for the dimensions of the electrical operated circuit breaker. Please underst this before using this type of breaker. method Front connection (Rear connection) Rear connection Plug-in Outline dimensions listing method Model Listed page Model Listed page NF125-CV/SV/HV NF400-CW/SW/SEW/HEW/REW 45 NV125-CV/SV/HV NF630-CW/SW/SEW/HEW/REW NF125-UV 767 NF400-UEW (3P) NF125-SEV/HEV/RV/ZEV NV400-CW/SW/SEW/HEW/REW 46 NF250-CV/SV/HV/SEV/HEV NF400-UEW (4P) NF250-RV NV630-CW/SW/SEW/HEW NF125-SGV/LGV/HGV/RGV NF00-CEW/SEW/HEW/REW/SDW 45 NF160-SGV/LGV/HGV NF00-UEW 47 NF250-SGV/LGV/HGV/RGV NV00-SEW/HEW NV125-SEV/HEV NV250-CV/SV/HV/SEV/HEV NF0-SEW, NF1250-SEW/SDW NF1600-SEW/SDW 4 NF250-UV 771 The drilling dimensions connection related dimensions are the same as the dimensions for the breaker body. Refer to the dimension drawings of each model. Note that for the rear connection type, four mounting holes are required even for the 2-pole or types. (2) Front connection (Rear connection) NF125-CV, NF125-SV, NF125-HV NV125-CV, NV125-SV, NV125-HV Front connection Insulation barrier (removable) OFF lock plate ON button Manual/automatic selection switch OPEN (TRIP) button P1P2 Operation circuit terminal cover mounting screw (M3 tapping) S1S2S4 Manual hle P1P2 Center line of electrical operation device Operation circuit terminal board (M3.5 screw) S1S2S Electrically operated base 61 Neutral pole 15 Front plate 164 Display hole (ON (green), OFF (red), TRIP (yellow)) Test button Operation circuit terminal cover (Stard supply) Power supply module M screw Remarks: 1. This cannot be mounted on the 2-pole breaker. 2. The test button is equipped only on the earth leakage circuit breaker. NF125-SEV, NF125-HEV, NF125-RV NF250-CV, NF250-SV, NF250-HV, NF250-SEV, NF250-HEV, NF250-RV NV125-SEV, NV125-HEV NV250-CV, NV250-SV, NV250-HV, NV250-SEV, NV250-HEV NF125-SGV/LGV/HGV/RGV NF160-SGV/LGV/HGV NF250-SGV/LGV/HGV/RGV Front connection Center line of electrical operation device Display hole (ON (green), OFF (red), TRIP (yellow)) Insulation barrier (removable) OFF lock plate P1P2 S1S2S4 P1P2 ON button Manual/automatic selection switch OPEN (TRIP) button S1S2S Operation circuit terminal cover mounting screw (M3 tapping) Operation circuit terminal board (M3.5 screw) Manual hle Electrically operated base Front plate Neutral pole Test button Operation circuit terminal cover (Stard supply) Power supply module A B B A A B B A M4 0.7 screw or f5 Front plate cut out Drilling plan Hexagon socket M bolt 24 A B 35 B A A B Drilling plan 35 B A 111 Center line of electrical operation device R1 R1 0 Center line of electrical operation device 126 M4 0.7 screw or f5 44 Front plate cut out Remarks: 1. The test button is equipped only on the earth leakage circuit breaker. 2. For details of external dimensions of breakers, please refer external dimension drawing of each model Other

186 46 Electrical Operated Outline Drawing NF400-CW, NF400-SW, NF400-SEW, NF400-HEW, NF400-REW, NF630-CW, NF630-SW, NF630-SEW, NF630-HEW, NF630-REW Motor drive type Front connection Center line of electrical operation device breaker 120 Trip button Insulating barrier NF400-UEW () Motor drive type Front connection Center line of electrical operation device breaker Center line of electrical operation device Center of breaker 20 Trip button Center line of electrical operation device f14 M12 bolt Center line of breaker Insulating barrier Operation circuit terminal block M3.5 screw f14 M12 bolt Max. conductor thickness 400A frame: t= 600/630A frame: t=10 Operation circuit terminal block (M3.5 screw) M6 or f7 2- Drilling plan Remark: 1. 2-pole models are with the central pole conductor removed. Conductor thickness t= max. 257 f12.5 ø ø f Drilling plan M6 screw or f7 Other NV400-CW, NV400-SW, NV400-SEW, NV400-HEW, NV400-REW, NV630-CW, NV630-SW, NV630-SEW, NV630-HEW Motor drive type Front connection NF400-UEW () Motor drive type Front connection Center line of electrical operation device breaker 120 Trip button Center line of electrical operation device Center line of electrical operation device Insulating barrier Test button f14 M12 bolt Center line of breaker f14 M12 bolt Center line of breaker Conductor thickness t= max. f Operation circuit terminal block M3.5 screw f7 Max. conductor thickness 400A frame: t= 600A frame: t= M6 screw or f7 Drilling plan f ø Neutral pole Operation circuit terminal block M3.5 screw Drilling plan M6 screw or f7

187 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing NF00-CEW, NF00-SDW, NF00-SEW, NF00-HEW, NF00-REW Motor drive type Front connection Center line of electrical operation device breaker 120 Trip button Center line of electrical Center line of breaker operation device Operation circuit Insulating barrier terminal block M3.5 screw Neutral pole f14 M12 bolt 277 Conductor thickness t=12 max M6 screw or f7 2- Drilling plan 243 Remark: 1. 2-pole models are with the central pole conductor removed. NF00-UEW Motor drive type Front connection Center line of electrical operation device breaker Center line of breaker Center line of electrical operation device Center line of electrical operation device Insulating barrier Center line of breaker Conductor thickness t= max. f f Trip button NV00-SEW, NV00-HEW Motor drive type Front connection Center line of electrical operation device breaker 110 Trip button 277 f14 M12 bolt Insulating barrier Test button f14 M12 bolt Neutral pole Operation circuit terminal block M3.5 screw Operation circuit terminal block M3.5 screw 277 f14 Conductor thickness t=12 max f M6 screw or f7 Drilling plan Drilling plan M6 screw or f7 290 Other

188 4 Electrical Operated Outline Drawing NF0-SEW, NF1250-SEW, NF1250-SDW Motor drive type Front connection f13 M12 bolt () 210 () (3 -pole) Center line of breaker Insulating barrier Operation circuit terminal block M3.5 screw Neutral pole Center line of electrical operation device breaker Conductor thickness t=2 max. Bolt max. M M screw or f10 Drilling plan 375 Remark: 1. 2-pole models are with the central pole conductor removed. NF1600-SEW, NF1600-SDW Motor drive type Front connection Other (15.5) ø (15.5) Operation circuit terminal block M3.5 screw Center line of electrical operation device Conductor thickness t=6 width 75 max Neutral pole Bolt max. M Drilling plan 375 M screw or f10

189 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Outline Drawing NF1600-SEW () Motor drive type Rear connection 120 NF1600-SEW () Motor drive type Rear connection Operation circuit terminal block M3.5 screw Operation circuit terminal block M3.5 screw 406 Mounting angle f17.5 f9.5 Mounting angle ø ø9.5 allowance Stud can be rotated Conductor thickness t=6 width 75 max. allowance f Bolt M1050 Stud can be rotated Conductor thickness t=6 width 75 max. 273 Bottom view 3 Mounting angle Mounting angle Drilling plan or less 160 or more M screw or f10 or less or more 269 Center line of electrical operation device NF1600-SDW () Motor-drive type Rear connection NF1600-SDW () Motor-drive type Operation circuit terminal block Mounting angle Stud can be turned 90º. M3.5 screw allowance Conductor thickness t=6width 75 max Remark: 2-pole models are models with the central pole removed. Rear connection Center of electrical operation device f17.5 f f9.5 f f11 15 Bolt M Operation circuit terminal block Mounting angle M3.5 screw Stud in horizontal direction. It cannot be turned 90. allowance 15 Conductor thickness 1.5 t=6width 75 max f11 Bolt M Bottom view f11 Bolt M Bottom view Bottom view Drilling plan Mounting angle Mounting angle Drilling plan M screw or f10 Drilling plan M screw or f or more 175 or more M screw or f or more 175 or more Other

190 50 Magnetic Contactor Starters Magnetic Contactor Starters A wide variety of lineup to meet all dems The MS-T/N Series Magnetic Starters are eco-friendly, ready for global use, compact, easy-to-use, built with safety in mind. Compatible with many international stards highly-reliable to meet various situations from switchboards to equipment. Magnetic Starters Magnetic Contactors All models in the MS-T series are equipped with terminal covers. Also, the series includes a wider range of operating coils. (10-A) All models in the MS-T series are equipped with terminal covers. Also, the series includes a wider range of operating coils. (10-A) List of Produced Models P.61 Selections P.64 P.73 List of Produced Models P.61 Selections P.64 P.75 Contactor Relays Thermal Overload Relays Can be used as control relays for magnetic contactors, using the large number of contacts to transmit signals. Can be used to protect motors against burning out when overloaded or under locking. List of Produced Models P.62 Selections P.65 P.7 List of Produced Models P.62 Selections P.65 P.1

191 51 Definite Purpose Magnetic Contactors Solid State Contactors Our lineup of magnetic contactors responds to a diverse range of customer needs. We have a lineup of high frequency switching, maintenance free, long life products that are ideal for applications where a switching sound is not desired. List of Produced Models P.62 Selections P.64 P.2 List of Produced Models P.92 Optional Units Motor Circuit These products can be easily attached to, or combined with, magnetic contactors, contactor relays thermal relays. There are a range of options available that have been designed with concern for safety ease of use. Selections P.65 P.9 Our wide lineup of related devices is ideal for controlling or protecting motors other devices. P.94

192 52 Magnetic Contactor Starters Product designation by purpose External appearance of representative models MS-T Series MS-N Series MS-T/N Series Magnetic Starters/Magnetic Contactors Stard (AC operated type) Reversing DC operated type Mechanically latched type MSOD-T MS-T MSO-T S-T MS-2 T MSO-2 T S-2 T SL/SLD-T SD-T MSOD-N Features/ Summary MS-N MSO-N S-N MS-2 N MSO-2 N S-2 N SD-N SL/SLD-N List Produced Models Selections Order Procedure Purpose/ Functions Can be used for general purpose activities such as starting stopping a motor or to protect a motor against burning out. Applicable for normal reverse rotation, reverse phase braking (plugging), together with use as a switch between normal emergency power sources. Can be used with DC control circuits. (The main circuit can be used with both AC or DC) The switch's state is mechanically maintained, so that no release will occur during blackouts or drops in power voltage. Uses Roadway lighting Memory circuits in industrial plants, etc. As an power switch between power purchase private power generation Product designation by purpose MS-T/N Series Magnetic Starters/Magnetic Contactors With fast wiring terminal 3 Pole Magnetic Contactors Thermal Overload Relays Thermal Overload Relays Contactor Relays Option Unit External appearance of representative models MS-T Series MS-N Series Magnetic Starter/ Contactor MSO-TBC S-TBC S-T32 TH-T TH-TSR Solid State Contactors Motor Circuit Purpose/ Functions Providing safety during maintenance inspections, such as by allowing easy wiring operations protecting against electric shocks without the need to install a protective cover. S-N Because there are only 3 main contacts no auxiliary contacts installed, the contact area for attachment to the circuit board is reduced. An auxiliary contact unit can also be attached to provide auxiliary contacts. TH-N TH-NSR Can be used to protect motors against burning out when overloaded or under locking. Overload phase failure protection models (TH- T/NKP), delayed trip models (TH-T/NSR) quick trip models (TH-T/NFS, TH- TFSKP & TH-NKF) are also available.

193 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Delay open type MSO/S-TDL Magnetic Starter with Overload, Phase Failure Protections MSO-TKP MS-T/N Series Magnetic Starters/Magnetic Contactors Magnetic Starter with Thermal Relays Saturable Reactors Magnetic Starters with Quick-trip Thermal Relays Magnetic Starters with Push Button switch MSO-TSR MSO-TFSKP MS-TPM MSO/S-NDL MSO-NKP MSO-NSR MSO-NFS/KF MS-NPM Features/ Summary Contactor prevent instantaneous drop-out when connected motors, resulting from momentary voltage drop or power interruption caused by lighting or similar. Starter or contactor remain closed for 1 to 4 seconds. Uses Temporary memory circuits for automated control equipment, etc. Protection functionality is provided against motor overloads, locking phase failure. Capable of providing protection against overloads locking, preventing unnecessary motions of thermal relays, for motors with long startup time or a large inrush current. Appropriate for protection of motors with a short allowed time during periods of locking, such as underwater motors compressors. Because a push button is integrated to magnetic starter, it can be operated without installing a separate push button. List Produced Models Selections Order Procedure Contactor type Contactor Relay Stard (AC operated type) DC operated type Mechanically latched type Delay open type With fast wiring terminal Magnetic Starter/ Contactor Thermal Overload Relays SR-T SRD-T SRL-T SRLD-T SR-TDL SR/SRD-TBC Contactor Relays Option Unit Can be used as control relays for magnetic contactors, etc., using the large number of electrical contacts to transmit signals. Can be used with DC control circuits. (The contact part can be used with both alternating or direct current) The switch's state is mechanically maintained, so that no release will occur during blackouts or drops in power voltage. Contactor prevent instantaneous drop-out when connected motors, resulting from momentary voltage drop or powor interruption caused by lighting or similar. Starter or contactor remain closed for 1 to 4 seconds. Providing safety during maintenance inspections, such as by allowing easy wiring operations protecting against electric shocks without the need to install a protective cover. Solid State Contactors Motor Circuit

194 54 Magnetic Contactor Starters Product designation by purpose External appearance of representative models Operation coil surge absorber unit UT-SA Optional Units (Magnetic Starters/Magnetic Contactors/Contactor Relays) UT Series Auxiliary contact blocks UT-AX Mechanical interlocks UT-ML Protective cover units for charging parts UN-CV/UN-CZ Auxiliary contact blocks UN-AX UN Series Protective cover units for terminals UN-CW Auxiliary contact unit with contacts for low level signals UN-LL22 Operation coil surge absorber unit UN-SA DC/AC interface unit for operating coils UN-SY Features/ Summary DC/AC interface unit for operating coils UT-SY Single attachment unit UT-HZ Reset release for thermal relays UN-RR LED display for thermal relays UN-TL Mechanical interlocks UN-ML Reset release for thermal relays UN-RR List Produced Models Selections Order Procedure Purpose/ Functions These products can be easily attached to, or combined with, magnetic contactors, contactor relays thermal relays. Please choose the appropriate product to match your intended purpose. Uses UT/UN-CV/CZ: Protection of the charging part UT/UN-CW: Protection of the terminal part UT/UN-SA: Suppressing switching surges in the coil UT/UN-AX: Increasing the number of auxiliary contacts UN-LL: Switching of low voltage minute electric current UT/UN-SY: Making it possible to switch magnetic contactors operating on alternating current using programmable controller output (24VDC) UN-TL: Displaying whether thermal relays are tripped. UT/UN-ML: Preventing simultaneous closure of reversing magnetic contactors UT/UN-RR: Enabling thermal resets outside the control board Magnetic Starter/ Contactor Product designation by purpose Solid State Contactors Related Components Optional Unit for Use with Solid State Contactors Electronic Motor Protection Relay Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors External appearance of representative models US-N US-K US-H Driving unit with output UA-SH Driving unit UA-DR1 Power control unit UA-PC ET-N Motor Circuit Purpose/ Functions High frequency switching, maintenance free, long life products that are ideal for applications where a switching sound is not desired. Uses Facilities such as hotels clean rooms Heater load switch for equipment such as injection molding machines The range of applications is exped when used in combination with US-N/K US-H series solid state contactors. Uses UA-DR1: For controlling alternating current control circuits UA-PC: For power control Electronic motor protection relay capable of protecting against overloads, locking phase failure during startup operation of alternating current motors, detecting phase reversals.

195 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Definite Purpose Magnetic Starters, Connectors Contactor Relays Definite Purpose Magnetic Contactors DC Interface Contactors MSOD-Q NC Main Contact Contactors DC Contactors Medium Voltage Vacuum Contactors - SD-Q B(D)-N DU(D)-N SH-V SD-QR (Reversing) Features/ Summary Can be operated directly using transistor output (24VDC0.1A) from programmable controllers, etc. b contacts (always closed contacts) are used as the main circuit contacts, so it has applications in motor controls power switches for electric light circuits. Uses For short circuits during the startup resistance of motors For ensuring smooth startup of alternating current motors Can be applied to controlling direct current motors of 440V or under switching of general direct current circuits Uses Controller for variable speed motors For use in dynamic brakes Exceptionally safe high capacity magnetic contactor with no arcing, as a result of the breaker inside the vacuum bulb List Produced Models Selections Order Procedure Related Components Low Voltage / Reduced Voltage Starter Pneumatic Time Delay Relays Voltage Detecting Relay Re-Starting Relay Star-Delta Starters Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays SRT(D)-N SRE UA-DL2 EYD/EY/EYF-N Option Unit Solid State Contactors A pneumatic timer for time intervals between seconds where a precise time interval is not required. Can be used for detecting drops in power supply voltage, such as for switching to private power generation as a result of a power outage, or when used in a voltage drop alarm. A relay that automatically restarts a loaded device, that has stopped as a result of voltage drops for a short time momentary blackouts, upon the resumption of power supply. Uses Motor heater overload circuits for various kinds of industrial plants Can be used to reduce electrical mechanical shock by reducing startup voltage controlling startup torque. Motor Circuit

196 56 Magnetic Contactor Starters MS-T Series Introduction Down-sizingS mall 10A frame model is over 16% smaller with a width of just 36mm!! There is a saying that "every bit helps" now with the industries smallest* general purpose Magnetic Contactor in its class, customers are able to more easily down-size their boards than ever before. For AC-operated 10A frame class general-purpose Magnetic Contactor (based on survey conducted by Mitsubishi dated September 2016) Example: Status where 5 units are arranged 43mm 5 units = 215mm Features/ Summary Reduction by 7mm! List Produced Models Selections Order Procedure 36mm 5 units = 10mm Reduction by 35mm! Magnetic Starter/ Contactor Thermal Overload Relays S-T10 (actual size) The optimized high-temperature gas discharge structure arc runner shape streamline the outline dimensions!! Traditional MS-N Series High-pressure gas Contactor Relays Option Unit Solid State Contactors Reduction by 13mm! Fixed contact Movable contact Arc New MS-T Series Optimized high-temperature gas discharge structure High-pressure gas opening Motor Circuit Fixed contact Movable contact Arc S-T50 (actual size)

197 /L1 2/T1 1/L1 1/L1 2/T1 3/L2 2/T1 4/T2 3/L2 4/T2 3/L2 4/T2 5/L3 6/T3 1 / L1 2/T1 1/L1 2/T1 5/L3 6/T /L3 6/T3 3/L2 4/T2 3/L2 4/T /L3 6/T3 5 / L3 6 / T 3 1/L1 2/T1 3/L2 4/T2 5/L3 6/T3 13 1/L1 3/L2 5/L /T1 4/T2 6/T /L1 3/L2 5 / L3 2/T1 4 / T 2 1/L1 2/T1 3/L2 4/T2 5/L3 6/T3 6 / T /L1 3/L2 5/L /T1 4/T2 6/T3 22 1/L1 3/L2 5 / L3 2/T1 4 / T 2 6 / T 3 1/L1 3/L2 5/L /L1 2/T1 3/L2 4/T2 1/L1 3/L2 5/L3 2/T1 4/T2 6/T3 2/T1 4/T2 6/T3 2/T1 4/T2 6/T /L3 6/T3 1/L1 3/L2 2/T1 4/T2 5/L3 6/T /L1 3/L2 5/L3 2/T1 4/T2 6/T3 1/L1 3/L2 5/L3 2/T1 4/T2 6/T3 1/L1 2/T1 1/L1 3/L2 4/T2 3/L2 5/L3 6/T3 5/L3 Low-Voltage Circuit P.664 Magnetic Contactor Starters P <AC operated type> Frame size Traditional MS-N Series New slimline MS-T Series Frame size Front view Front view 11A 13A 20A 25A 32A S-N10 S-N11 (Auxiliary 1-pole) S-N12 (Auxiliary 2-pole) S-N20 S-N mm! -10mm! 35A 50A 65A 0A /L1 2/T1 3/L2 4/T2 5/L3 6/T mm! mm! S-T10 S-T12 (Auxiliary 2-pole) S-T20 S-T25 S-T32 43 A NEW Traditional MS-N Series Front view /L1 3/L2 5/L3 2/T1 4/T2 6/T /L1 3/L2 5/L3 2/T1 4/T2 6/T /L1 3/L2 5/L3 2/T1 4/T2 6/T3 1/L1 3/L2 5/L3 2/T1 4/T2 6/T3 Features/ Summary New slimline MS-T Series Front view <DC operated type> S-N35 S-N50 S-N50AE S-N65 S-N65AE S-N /L1 3/L2 5/L3 2/T1 4/T2 6/T3 S-T35 S-T50 S-T65 S-T0 S-T mm! 63 1/L1 3/L2 5/L3 2/T1 4/T2 6/T3-12mm! Front view 13A 1A 20A 32A S-N95 1/L1 3/L2 5/L3 2/T1 4/T2 6/T3 List Produced Models Selections Order Procedure Traditional SD-N Series New slimline SD-T Series Front view Traditional SD-N Series Front view Front view Front view 1/L1 3/L2 5/L3 2/T1 4/T2 6/T3 SD-N11 SD-N12 SD-N mm! NEW NEW SD-T12 SD-T20 SD-T21 SD-T32 35A 50A 65A 0A A 75 Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit SD-N35 75 SD-N50 SD-N65 SD-N0 SD-N95 75 Solid State Contactors New slimline SD-T Series Front view -13mm! -12mm! SD-T35 SD-T50 SD-T65 SD-T0 SD-T Motor Circuit

198 5 Magnetic Contactor Starters Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit Stardization S tardization New integrated terminal covers Traditional solution: Cover + Contactor Reduce your coil inventory by up to 50% The 14 types of operation coil ratings available with the SN Series have been halved to types with that increasing the applicable voltage range. Users can reduce their inventory, by integrating the types of coils manufactured, a shorter delivery can be realized. Coil designation 12VAC 24VAC 4VAC VAC 120VAC 127VAC 200VAC 220VAC 230VAC 260VAC 30VAC 400VAC 440VAC 500VAC Rated voltage [V] 50Hz 60Hz By integrating the electromagnetic field analysis drive analysis, inconsistency in the electromagnetic attraction force is suppressed rise of the coil temperature is reduced. Capable of direct drive with transistor output of PLC, etc The adopted high-efficiency polarized electromagnet greatly reduces the coil power consumption, enables all models to be directly driven with a 24VDC, 0.1A rating transistor output. (24VDC coil) 7W 9W New Model 2.2W 2.2W Lowering Rate 69% 76% 2.2W Target frame : 10A to 50A frame The perennial issues of remembering to order the terminal covers, fitting them correctly or loosing them in the process are challenges of the past. The integrated terminal cover system means they are always there, on the Magnetic Contactor or its Auxiliary contact, ready to be used. Coil power consumption(w) [W] 7 Displacement [mm] 7W Target frame : 10A to 35A frame Coil designation 12VAC 24VAC 4VAC VAC 200VAC 300VAC 400VAC 500VAC Rated voltage [V] 50Hz/60Hz Time [ms] OFF state ON state When 150VAC 60Hz is applied on 200VAC coil 13A Frame (Coil:12/24VDC) 20A Frame (Coil:12/24VDC) 32A Frame (Coil:12/24VDC) *4VDC to 220VDC:3.3W Conventional Model Target frame : 10A to 32A frame A terminal cover is included as stard in the contactor!! * The conventional eight types are available for the 50A larger frames. Reduced power consumption 13A Frame Reduction by 69% Coil power consumption (W) [W] 9 9W *DC-operated models Reduced power consumption 20A Frame Reduction by 76% 2.2W W Traditional New Traditional New

199 Low-Voltage Circuit P.664 Magnetic Contactor Starters P S Safety & Quality afety & Quality Terminal cover with finger protection function In addition to the Magnetic Contactor, a terminal cover has been provided as a stard for the thermal, magnetic relay auxiliary contact unit options. This realizes a finger protection function that complies with the DIN VDE Stards, prevents electric shocks, increases safety during maintenance inspections. [Finger Protection] In the provisions regarding worker safety accident protection during use of low-voltage switchgear controlgear assemblies set forth with DIN EN 50274/VDE 0660 Teil 514, the range for providing protection against contact of live sections is divided into "Finger Safe (preventing finger contact)" "Back of h safe (protecting back of h contact), stards are provided. The MS-T Series terminal cover satisfies the requirements of these provisions. A light touch Target frame : All S-T Series The MS-T Series' auxiliary contacts can operate with load as light as 20V 3mA making it suitable for direct control/operation from a PLC output. Target frame : 10A to 50A frames Features/ Summary List Produced Models Selections Order Procedure S Smart wiring mart Wiring Magnetic Starter/ Contactor Thermal Overload Relays Smart design means Smart wiring Target frame : 10A to 50A frames The integrated terminal covers have an additional benefit in that they act as a guide to improve wiring efficiency but also retain the terminal screw in place: no mislaying the screw, no dropping it or having trouble reinserting it in to the terminal block just fast efficient wiring. Fast wiring terminals (model name with suffix BC ) are also available to further improve wiring efficiency, workability hence productivity. Easy wiring! Contactor Relays Option Unit Solid State Contactors Motor Circuit Screw holder lifts up the screw. Insert a ring crimp lug Tighten the screw

200 60 Magnetic Contactor Starters Easy branch circuit wiring with Motor Circuit optional connection conductor unit Target frame : 10A to 32A frames Easy wiring is available for the new MS-T Series by using the Motor Circuit optional connection conductor unit, contributing your productivity improvement. Unit eliminates the need of wires Motor Circuit Selections Order Procedure Solid State Contactors List Produced Models Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Features/ Summary Global Stard Global S tard Complies with main International Stards In addition to compliance with the main International Stards including IEC, JIS, UL, CE, CCC, we plan to acquire compliance with Shipping Stards other International Stards. We hope to contribute to your business expansions overseas. Stards Applicable stard Safety certification stard International Japan European countries China U.S. & Canada EN EC directive Certificate authority GB Note IEC JIS Note : Also compliant with the requirements for mirror contacts comply with IEC Annex F. Higher SCCR value achieved by using with Motor Circuit When the MMP-T Series the MS-T Series are used together, the higher SCCR (UL short-circuit current rating) value, can be achieved. That will be a great support for your business in North America. * For details on the SCCR value when used in combination with the Motor Circuit, refer to the Motor Circuit catalog.

201 Low-Voltage Circuit P.664 Magnetic Contactor Starters P List of Produced Models Magnetic Starters/Magnetic Contactors (NonReversing) Frame Category AC-3 Rated capacity [kw] Model Name Magnetic Starters Magnetic Contactors Enclosed Open type Open type Auxiliary contact 3-element (2E) thermal MS-KP Open time quick motion type MS-QM Delay open type MSO-DL With terminal cover Anticorrosion treatment S-YS With terminal cover (Note 6) Stard specifications MS- With push button MS-PM Stard specifications 3-element (2E) thermal With saturable reactor 3-element (2E) thermal With saturable reactor 2-element Quick-acting characteristics thermal 3-element (2E) Quick-acting characteristics thermal 3-element (2E) Quick-acting characteristics thermal MSO- MSOD- Open time quick motion type MSO-QM Surge absorber mounted type Wiring streamlining terminal Anticorrosion treatment Mechanically latched type Stard specifications Surge absorber mounted type Open time quick motion type S-QM Wiring streamlining terminal Delay open type S-DL Mechanically latched type Class 2 heat resistance S-FN Class 2 heat resistance Mechanically latched type 220V 440V stard special MSO-KP MSOD-KP MSO-SR MSOD-SR MSO-KPSR MSOD-KPSR MSO-FS MSOD-FS MSO-FSKP MSOD-FSKP MSO-KF MSO-SA MSOD-SA MSO-BC MSOD-BC MSO-YS MSOD-YS MSOL- MSOLD- MSO-CW S- SD- S-SA SD-SA S-BC SD-BC S-CW SL- SLD- SL-TFN SLD-TFN (Note3) 2a2b New release T10 T12 T20 T21 T25 T32 T35 T50 T65 T0 T N125 N150 N10 N220 N300 N400 N600 N [2.2] [2.7] [3.7] [4] [5.5] [7.5] [7.5] [11] [15] [19] [22] [2.7] [4] [7.5] [7.5] [11] [15] [15] [22] [30] [37] [45] 1a 1a1b 1a1b 1b 2a 2a Note 1: The figure in the square brackets indicates the rated current shown on the rating plate of the product at which the category AC-3 opening/closing durability is 2,000,000 times (1,000,000 times for the T20 30V). Refer to the electric durability curve for the life performance. 2a2b Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit

202 62 Magnetic Contactor Starters Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Magnetic Starters/Magnetic Contactors (Reversing) Frame Category AC-3 Rated capacity [kw] Auxiliary contact (Notes 4 to 6) Model Name Stard specifications 3-element (2E) thermal Magnetic Starters MS- MS-KP MSO- MSOD- MSO-KP MSOD-KP MSO-SR MSOD-SR MSOL- MSOLD- S- SD- S-SA SD-SA S-YS S-BC SD-BC S-CW SL- SLD- S-FN New release 2X 2X 2X 2X 2X 2X 2X 2X 2X 2X 2X 2X 2X 2X 2X 2X 2X 2X 2X T10 T12 T20 T21 T25 T32 T35 T50 T65 T0 T N125 N150 N10 N220 N300 N400 N600 N V [2.2] [2.7] [3.7] [4] [5.5] [7.5] [7.5] [11] [15] [19] [22] V [2.7] [4] [7.5] [7.5] [11] [15] [15] [22] [30] [37] [45] (1a 2) Stard +2b (1a1b 2)+2b 2a2b 2 3a3b 2 4a4b 2 (1b 2) Special +2b (2a 2)+2b MSO-KPSR MSOD-KPSR MSO-FS MSOD-FS MSO-FSKP MSOD-FSKP MSO-KF MSO-SA MSOD-SA MSO-BC MSOD-BC MSO-CW MSO-YS MSOD-YS (Note3) Notes 1: indicates out of manufacturing range, * indicates to be released soon. 2: The value given in brackets for the Class AC-3 rated capacity applies to the enclosed Magnetic Starter. 3: The T65 to N00 type AC operation coils are a surge absorber-installed type so the coil does not generate an open/close surge. Therefore, the surge absorber for coils is not required. 4: The +2b for the T10 to T20 auxiliary contact arrangements in the Reversing type represents the b contact built into the UT-ML11 interlock unit. This does not need to be specified when ordering. 5: For the auxiliary contact arrangement in the reversing type, the auxiliary contact arrangement combination for two Magnetic Contactors is indicated as 2. When using the stard contact arrangement, there is no need to make a special designation, but when using the special arrangement, designate the contact arrangement for two units. <Designation example> In case of 1b 2 + 2b: 2B 6: The auxiliary contact arrangement for the mechanically latched type differs from the delay open type. Motor Circuit Magnetic Contactors Open type Enclosed Open type Stard specifications 3-element (2E) thermal With saturable reactor 3-element (2E) thermal With saturable reactor 2-element Quick-acting characteristics thermal 3-element (2E) Quick-acting characteristics thermal 3-element (2E) Quick-acting characteristics thermal Surge absorber mounted type Wiring streamlining terminal With terminal cover Anticorrosion treatment Mechanically latched type Stard specifications Surge absorber mounted type Anticorrosion treatment Wiring streamlining terminal With terminal cover Mechanically latched type Class 2 heat resistance With reversible conductor (both power supply load side) common on power supply side with crossover conductor common on load side with crossover conductor reverse-phase switch on load side with crossover conductor S-SD SD-SD S-SG SD-SG S-SX SD-SX S-SF SD-SF

203 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Thermal Overload Relays Frame Heater designation (Stard specifications) Thermal Overload Relays Stard specifications TH- With saturable reactor TH-SR 2-element Quick-acting characteristics thermal TH-FS 3-element (2E) thermal TH-KP 3-element (2E) thermal With saturable reactor TH-KPSR 3-element (2E) Quick-acting TH-FSKP characteristics thermal TH-KF With terminal cover TH-CW Wiring streamlining terminal TH-BC Anticorrosion treatment TH-YS New release T1 T25 T50 T65 T N120 N120TA N220 N400 N to to to to to 42 to to to to to 660 Note 1: indicates out of manufacturing range. Contactor Relays Features/ Summary Frame Number of contact Contact arrangement T5 5 5a 4a1b 3a2b T9 9 9a 7a2b 5a4b List Produced Models Stard SR- DC operated type SRD- Mechanically latched SRL- type SRLD- With large rated SR-JH auxiliary contacts SRD-JH SR-LC With overlap contact SRD-LC Delay open type SR-DL SR-BC With fast wiring terminal SRD-BC SR-SA With surge absorber SRD-SA Notes 1: indicates out of manufacturing range. 2: Refer to the individual rating table for the contact rating when using a type with large capacity contact or type with overlap contact. The value given in brackets is the value for switching the load with two poles installed in a series. 3: When using the mechanically latched type (SRL-, SRLD-), one each can be mounted on the opening coil closing coil. 4: Only the side-on auxiliary contact unit UT-AX11 can be mounted on the mechanically latched type SRL-T5 or SRLD-T5. Only UN-AX11 can be mounted on SRL-N4 or SRLD-N4. 5: Both the surge absorber unit DC/AC interface unit cannot be additionally mounted onto the Contactor Relay's coil terminal. 6: A live section protection cover is provided as a stard. 7: The minimum applicable load level for the contacts at the SR(D)-T9 head-on section (four terminals on upper level) is the same as UT-AX2/4. Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit

204 64 Magnetic Contactor Starters Features/ Summary Composition of the Model Code Magnetic Starters Enclosed Magnetic Starters MS MS Basic type AC operated type Non-Reversing/Reversing No code Non-Reversing 2 Reversing Frame size T10,T12,T21,T35,T50,T65,T0,T Note 1. For details of product manufacturing specifications applicable devices, please refer to the table of all models manufactured (pages 71 72) also to the individual pages for each model. Also, some combinations of model codes may not be able to be manufactured. If you are uncertain about whether particular models can be combined, please contact us for further advice. 2 T21 KP Combined Thermal Overload Relays No code AR No code KP FS FSKP Manual reset (stard) Automatic reset SA Combined Thermal Overload Relays With 2-element Thermal Overload Relays With 3-element Thermal Overload Relays With 2-element quick trip type Thermal Overload Relays With 3-element quick trip type Thermal Overload Relays PM Push-button operation (only non-reversible type) No code PM PS No code SA Stard specifications without push-button With push-button (with thermal reset) With push-button (without thermal reset) Operation coil specifications Stard Surge absorber mounting type List Produced Models Open type Magnetic Starters MSO 2 T10 BC KP SA YS Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays MSO MSOD MSOL MSOLD No code Basic type AC operated type DC operated type MechanicalIy latched AC operated type Mechanically latched DC operated type Non-Reversing/Reversing Non-Reversing 2 Reversing Frame size T10-T Finger protection No code BC CW No code AR Stard With terminal cover Applicable model T10-T50 T65, T0 Reset method of Thermal Overload Relays No code KP Manual reset (stard) Automatic reset Combined Thermal Overload Relays SR KPSR FS FSKP With fast wiring terminal With 2-element Thermal Overload Relays With 3-element Thermal Overload Relays With 2-element delay trip type Thermal Overload Relays With 3-element delay trip type Thermal Overload Relays With 2-element quick trip type Thermal Overload Relays With 3-element quick trip type Thermal Overload Relays Special environment No code YS Operation coil operation circuit specification Applicable model No code SA DL Stard Anticorrosion treatment specification Stard With surge absorber Delay open type Applicable model T10-T T10-T50 T12, T21 Magnetic Contactors Option Unit S 2x T10 BC SA Basic type Frame size Solid State Contactors Motor Circuit S SD SL SLD AC operated type DC operated type MechanicalIy latched AC operated type Mechanically latched DC operated type No code BC CW T10-T Finger protection Stard With fast wiring terminal With terminal cover Applicable model T10-T50 T65, T0 Operation coil operation circuit specification No code SA DL Stard With surge absorber Delay open type Applicable model T10-T50 T12, T21 Non-Reversing/Reversing No code Non-Reversing 2 Reversing With special auxiliary contact No code JH Stard With large rated auxiliary contacts Applicable model All series T10-T

205 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Thermal Overload Relays TH Basic type Thermal TH Overload Relays Frame size T1, T25, T50, T65, T Note: Frame size classification by mounting type Magnetic Starters for independent mounting T25 For Magnetic Starters T1 T1 BC KP Reset method of Thermal Overload Relays No code AR Manual reset (stard) Automatic reset Combined Thermal Overload Relays No code KP SR KPSR FS FSKP 2-element Thermal Overload Relays 3-element Thermal Overload Relays 2-element delay trip type (with saturable reactor) 3-element delay trip type (with saturable reactor) 2-element quick trip type Finger protection No code BC CW Stard YS 3-element quick trip type With fast wiring terminal With terminal cover Applicable model T1, T25, T50 T65 Special environment Applicable model No code Stard Anticorrosion T1, T25, YS treatment T50, T65, T specification Features/ Summary List Produced Models Selections Order Procedure Contactor Relays SR T5 BC SA SR SRD SRL SRLD Basic type AC operated type DC operated type MechanicalIy latched AC operated type Mechanically latched DC operated type Frame size T5, T9 Finger protection No code BC Stard With fast wiring terminal Applicable model T5, T9 Operation coil operation circuit specification Applicable model No code SA No code JH Stard With surge absorber With special contact DL LC Stard With large rated auxiliary contacts Delay open type With overlap contact T5, T9 Applicable model T5, T9 Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Optional Units UT AX 4 BC Option Unit UT Basic type Optional units AX Unit type Additional auxiliary contacts Application UT ML Mechanical interlocks UT SA Surge absorbers UT HZ For thermal relay independent mounting UT SD Reversible connection wire (conductor) UT SG Crossover connection wire (conductor) UT Finger protection No code BC Stard With fast wiring terminal 1 to 2-digit number Applicable model All units AX, ML, HZ Unit specification, applicable model, others Solid State Contactors Motor Circuit SY DC/AC interface for operation coil UT

206 66 Magnetic Contactor Starters Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit Explanation of terms Item Purpose Meaning of terms 3. Performance 2. Rating 1. Devices 4. Characteristic 5. Operation Others (1) Magnetic starter (magnetic switch) (2) Magnetic contactor (3) AC magnetic contactor (4) DC magnetic contactor (5) Magnetic contactor with mechanical latch (1) Rated insulation voltage (2) Rated operating voltage (3) Rated Capacity (4) Rated operating current Operating Coil Designations Operating Coil Ratings (1) Closed Circuit Capacity (2) Interrupting Capacity (3) Switching Frequency (4) Interlock (5) a contact (6) b contact (7) Main circuit () Operating (control) circuit (9) Line starting (10) Star-delta starting (11) Category AC-3 (12) Category AC-4 (13) Category AC-1 (14) 2E 3E Combines an magnetic contactor thermal relay. An magnetic contactor that uses an electromagnet powered by an AC power source. An magnetic contactor that uses an electromagnet powered by a DC power source. SD A contactor where the contacts are closed (ON) by electrical (via a closing coil) or mechanical operation, the closed state is maintained by the mechanical latch even if that controlling force is removed. SL(D) Opening the circuit (OFF) is achieved by electrically (via a tripping coil) or mechanically tripping the contacts. Drives the switching action of an magnetic contactor by magnetizing the iron core of an electromagnet then demagnetizing it, creating then removing the attractive force. The model code which must be specified at time of order indicates a representative value of the rated operating voltage. ACV, DCV The rated operating voltage for the operating coil (nominal voltage) the frequency (AC only). VHz, DCV The current value at which the circuit can be closed (contacts ON) under the conditions determined by the stard. A The current at which the circuit can be broken (contacts OFF) under the conditions determined by the stard. A The number of times the conductor can be switched under the conditions determined by the stard. times/hr Name display of representative models (Numbers go inside ) (6) Delayed release magnetic contactor A contactor that can maintain a closed circuit contact for a few seconds by discharging the capacitor, S-DL in the event of a voltage drop or momentary power interruption occurring to the control circuit. (7) Reversing magnetic contactor A magnetic contactor which can reverse the motor by switching the contacts S-(D)-2x, SL(D)-2x When the motor experiences excess overcurrent (overload) as a result of overloading, locking or () Thermal relay phase failure, the bimetal strips inside the relay are bent by the heat, which trips the output TH contacts on the magnetic contactor opens the circuit, preventing the motor from burning out. (5) Open thermal current (lth) (6) Operating Coil This is a contactor that switches the main contact parts using the power of the electromagnet. Accordingly, there are both AC DC magnetic contactors, depending on the type of main circuit (AC or DC). The voltage that is used as the stard for guaranteeing the withst voltage determining the insulation distance. V (both AC DC) The voltage that determines closed circuit capacity, interrupting capacity, switching frequency switching durability. -VAC, VDC The capacity of the maximum load capable of being applied at the rated operating voltage. Motor φ kw, Resistance φ kw The maximum amount of current capable of being applied at the rated operating voltage while maintaining satisfactory performance. AC-3A, AC-4A, DC1A The amount of current that allows the passage of electric current for hours without the temperatures of the individual parts rising above their rated values without switching magnetic contactors. (4) Switching Durability (Lifespan) The maximum number of times an magnetic contactor can be switched, in actual operation without interference, under the conditions determined by the stard. x 10,000 times Mechanical durability Durability against mechanical wear while being switched, without electrical current passing through the main circuit, under the conditions determined by the stard. x 10,000 times Electrical durability Durability against electrical wear while being switched, with electrical current passing through the main circuit, under the conditions determined by the stard. x 10,000 times (1) Operating Voltage The minimum voltage, in the case where the magnetic contactor excites the operating coil, at which the to V contacts can be closed (ON). (In the case of mechanical latch format, closing voltage tripping voltage) (Specified value: 5% or less of rated operating voltage) to V Maximum voltage at which the contacts are opened (OFF), when the voltage applied to (2) Open voltage Specified value: 20% or more of rated operating voltage during the magnetic contactor's operating coil is gradually reduced. alternating current operation 10% or more during direct current operation (3) Operating time The time from when the operating coil is excited, or from when it is demagnetized, until the operation of the contacts (ON or OFF) is completed. ms (4) Operating Coil [According to 2.(6)] Instantaneous power input The instantaneous capacitance (input VA) immediately after the operating coil is excited. In the case of direct current operate, this is lower than the continuous power input. Alternating current: VA, Direct current: W (=VA) Continuous power input The capacitance of the coil (power consumption) after the operating coil has been excited the contacts closed. Alternating current: VA, Direct current: W (=VA) (1) Inching Inching or jogging is where the startup current is frequently switched by small rotations of the motor, etc. (2) Plugging (reverse phase braking) Stopping the motor by suddenly switching the connection of the contacts to the reverse phase. This uses auxiliary a contacts of an magnetic contactor that has already been switched ON, to (3) Self Maintenance of Status maintain the ON status of the circuit that passes current though the operating coil of that contactor, even if there is no ON signal. This is canceled by an OFF operation or a power interruption, etc. As in the reversing format, when two magnetic contactors must not be set to ON at the same time, in order to make sure that one contactor cannot be switched to ON, the magnetic contactor that has already been switched ON prevents the other magnetic contactor from switching to ON. The two types of interlock are mechanical interlock, which uses a mechanical structure, electrical interlock which uses auxiliary b contacts. This is a contact that is normally open, which closes when power is supplied to the operating coil. It is also called an NO (Normally Open) contact. This is a contact that is normally closed, which opens when power is supplied to the operating coil. It is also called an NC (Normally Closed) contact. Circuits with a large electric current flow (from several A to around 0A), such as motors electric light circuits, etc., are switched by the main contact. (Terminal number between 1/L1-2/T1, 3/L2-4/T2, 5/L3-6/T3) Circuits with small current flows (from several tens of ma to several A), such as the operating coil of an magnetic contactor or display circuits, are switched with auxiliary a b contacts. This is the most common way starting a motor, where the entire voltage is applied to the motor to start or stop it. Also called full voltage starting. When starting the motor, the winding is arranged in a star to reduce the electrical mechanical shock. After starting the winding is changed to a delta connection. The current used during starting is 1/3 of that for line starting, making this the cheapest reduced voltage starting method. Responsible for switching to start stop the motor during continuous operation. (Durability testing uses 6 times the rated operating current for closing the circuit current equal to the rated operating current for breaking the circuit) Responsible for switching the startup current of the motor. (Durability testing uses 6 times the rated operating current for both closing breaking the circuit), Can also be applied to inching plugging. Responsible for switching the electric heat resistance load, etc., so that inrush current during starting is almost zero. (Durability testing uses current equal to the rated operating current for closing breaking the circuit) 2E: A motor protection relay that provides overloading/locking + phase failure protection, has a thermal relay electronics. 3E: An electronic motor protection relay that provides overload/locking + phase failure + antiphase (reverse phase) protection. Sealed model: MS Open model: MSO(D), MSOL(D) For use with both alternating current direct current main circuits: S(D), SL(D) For use with direct current main circuits only: DU(D) S Ith=A TH-KP, ET-N ET-N

207 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Coil characteristics Alternating voltage operation type For S-T10 to T50 types, SR-T5 T9 types Coil designation Rated voltage [V] 50Hz/60Hz 24VAC 24 4VAC 4-50 VAC VAC VAC VAC VAC Coil indication Rated voltage frequency Notes 1 : Even when the single rating (example: 200V60Hz) is specified for an order, the above rating voltage is indicated on the product. 2 : Even when the single rating (example: 200V60Hz) is specified for an order, the above rating voltage is indicated on the product. For S-N35, N50AE, N65AE, B-N20 types, For SR-K type, For SRT-NN/NF types Coil designation Rated voltage [V] 50Hz/60Hz 12VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC Coil indication Rated voltage frequency For S-N35SA, B-N20SA types, For SRT-NNSA/NFSA types Coil Rated voltage [V] Coil Varistor voltage designation 50Hz/60Hz indication [V] 12VAC VAC VAC Rated 120 VAC voltage 120VAC VAC frequency 200VAC VAC VAC For S-T65 to T types, For S-N50 to N00, B-N65/N, DU-N30 to N 260 types Coil designation Rated voltage [V] 50Hz/60Hz 24VAC (Note 1) 24 4VAC (Note 1) 4-50 VAC VAC VAC VAC VAC Coil indication Rated voltage frequency Notes 1 : The 24VAC 4VAC coils for the following model names cannot be manufactured. 24VAC coil: S-N10/N220, N300/N400, N600/N00 DU-N10, N260 4VAC coil: S-N600/N00 2 : The coil ratings are different for some application models such as the delay open type (S-TDL, S-NDL). Please refer to the corresponding page. For S-T10SA to T50SA types, SR-T5SA T9SA types Coil Rated voltage [V] Varistor voltage Coil indication designation 50Hz/60Hz [V] 24VAC VAC VAC -127 Rated voltage 4 200VAC frequency 4 300VAC VAC Notes 1 : Add "SA" to the end of the type name to order the operation coil surge absorber mounting type (varistor). Example: S-T10SA VAC 2 : Even when the single rating (example: 200V60Hz) is specified for an order, the above rating voltage is indicated on the product. Note 1 : Even when the single rating (example: 200V60Hz) is specified for an order, the left rating voltage is indicated on the product. Designations of the coils with the following voltage frequency specifications are as follows. 220V60Hz Designation 200VAC 30V50Hz Designation 400VAC 240V50Hz Designation 230VAC 220V50Hz Designation 230VAC 415V50Hz Designation 400VAC Notes 1 : Add SA to the end of the model name to place an order for Magnetic Contactor with surge absorber (varistor). Example: S-N35SA VAC 2 : Even when the single rating (example: 200V60Hz) is specified for an order, the left rating voltage is indicated on the product. Designations of the coils with the following voltage frequency specifications are as follows. 220V60Hz Designation 200VAC 240V50Hz Designation 230VAC 220V50Hz Designation 230VAC 3 : Variations other than those indicated on the left cannot be manufactured. 4 : S-N50AE N65AE are already equipped with a varistor. Therefore, no need to add SA to the end of model name for an order. For S-T65QM to TQM types, For S-N50QM to N400QM types Coil designation Rated voltage [V] 50Hz/60Hz Coil indication VAC -127 Rated voltage 200VAC frequency Note 1 : Variations other than coil designations of VAC 200VAC cannot be manufactured. Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Coil designation is the model code which must be specified at time of order. For information about whether or not a product with a special coil of the rated voltage designation can be manufactured, please contact your dealer or our company. Note that a special coil is manufactured without certifications for the various stards (no stard marks). Motor Circuit

208 6 Magnetic Contactor Starters DC operated type For SD-T12 to T types, SRD-T5 T9 types Coil designation 12VDC 24VDC 4VDC VDC 110VDC 125VDC 200VDC 220VDC Rated voltage 12VDC 24VDC 4VDC VDC 110VDC VDC 200VDC 220VDC Coil indication Rated voltage Notes 1 : The operating coil terminal has a polarity (excluding T35 to T types). Connect the positive side to terminal number A1 (+) the negative side to A2 (-). 2 : If the operation power supply is a rectifier, open close the coil on the DC side. For SD-T12SA to T50SA types, SRD-T5SA T9SA types Coil designation 12VDC Rated voltage 12VDC Coil indication Varistor voltage [V] 24VDC 24VDC 47 4VDC 4VDC 120 VDC VDC 4 Rated voltage 110VDC 110VDC 4 125VDC VDC 4 200VDC 200VDC 4 220VDC 220VDC 4 Notes 1 : If the type with surge absorber for operation coil (varistor) is required, add SA to the end of the model when placing your order. Example: SD-T21SA VDC 2 : The operating coil terminal has a polarity (excluding T35SA to T50SA types). Connect the positive side to terminal number A1 (+) the negative side to A2 (-). 3 : Variations other than the above cannot be manufactured. 47 Features/ Summary List Produced Models Selections Order Procedure For SD-N35 to SD-N400, BD-N20 to N, DUD-N30 to N260 types, For SRD-K type, For SRTD-NN/NF types Coil designation 12VDC 24VDC 4VDC VDC 110VDC 125VDC 200VDC 220VDC Rated voltage 12VDC 24VDC 4VDC VDC 110VDC VDC 200VDC 220VDC Coil indication Rated voltage Notes 1 : The coils do not have polarity. 2 : If the operation power supply is a rectifier, open close the coil on the DC side. 3 : Two coils are internally connected in series for SD-N0 to SD-N400 DUD-N60 to DUD-N260 types. For SD-N35SA, SRTD-NNSA/NFSA types, For BD-N20SA type Coil designation 12VDC Rated voltage 12VDC Coil indication Varistor voltage [V] VDC 24VDC 120 4VDC 4VDC 120 VDC VDC 4 Rated voltage 110VDC 110VDC 4 125VDC VDC 4 200VDC 200VDC 4 220VDC 220VDC 4 Notes 1 : Add SA to the end of the model name to place an order for Magnetic Contactor with surge absorber (varistor). Example: SD-N21SA VDC 2 : The coils do not have polarity. 3 : Variations other than the above cannot be manufactured. Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays For D-N600/N00 types Coil designation 24VDC 4VDC VDC 125VDC 200VDC Rated voltage 24VDC 4VDC -110VDC VDC VDC Coil indication Rated voltage Notes 1 : The operating coil terminal has polarity. Connect the positive side to terminal number A1 (+) the negative side to A2 (-). 2 : If the operation power supply is a rectifier, open close the coil on the DC side. 3 : Products with the 12VDC coil designation cannot be manufactured. Option Unit Solid State Contactors Motor Circuit Mechanically latched type For SL(D)-T21 to T, SL(D)-N35 to SL(D)-N00, SRL(D)-T5 types For alternating current For direct current Coil Rated voltage [V] Coil Coil indication designation 50Hz/60Hz designation Rated voltage Coil indication VAC VDC (Note 2) 12VDC 200VAC VDC 24VDC Rated voltage 300VAC VDC 4VDC frequency Rated voltage 400VAC VDC V-110VDC 500VAC VDC 120V-125VDC 200VDC 200V-220VDC Notes 1 : In addition to the alternating current coils with the rated voltages frequencies indicated on the left, products with the following can be manufactured. For SRL-T5 or SL-T21 SL-N35 to SL-N0 24VAC (24V, 50/60Hz), 4VAC(4-50V, 50/60Hz) For SRL-T5 or SL-T21 12VAC (12V, 50/60Hz) 2 : A coil with the rated voltage of 12VDC cannot be manufactured for N0 to N00 types. 3 : The coils for direct current do not have polarity.

209 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Application to motor load Full-voltage starting In the case of stard operation (not including inching), select a frame where the rated capacity of the magnetic starters contactors is greater than the rated capacity of the motor. Can be applied to a stard 3 phase (3 φ) motor Indicates the heater designation of a thermal relay for a stard 3 phase motor the frame of the magnetic starter applicable to it. Motor capacity [kw] Heater designation [A] (setting range) 200 to 220V 400 to 440V Magnetic Contactors frame Heater designation [A] (setting range) (0.015) 0.12 (0.1 to 0.16) (0.025) 0.17 (0.14 to 0.22) (0.03) 0.24 (0.2 to 0.32) (0.035) 0.35 (0.2 to 0.42) (0.2 to 0.42) 0.24 (0.2 to 0.32) (0.07) 0.5 (0.4 to 0.6) 0.35 (0.2 to 0.42) (0.55 to 0.5) 0.35 (0.2 to 0.42) (0.15) 0.9 (0.7 to 1.1) 0.5 (0.4 to 0.6) (1 to 1.6) 0.7 (0.55 to 0.5) (0.3) 1.7 (1.4 to 2) 0.9 (0.7 to 1.1) (1.7 to 2.5) 1.3 (1 to 1.6) (0.55) 2.5 (2 to 3) 1.3 (1 to 1.6) (2. to 4.4) 1.7 (1.4 to 2) (1.0) 5 (4 to 6) 2.5 (2 to 3) (5.2 to ) 3.6 (2. to 4.4) (1.9)2.2 9 (7 to 11) 5 (4 to 6) (2.5) 11 (9 to 13) 5 (4 to 6) (3.0) 11 (9 to 13) 6.6 (5.2 to ) (12 to 1) 6.6 (5.2 to ) (1 to 26) 11 (9 to 13) (24 to 34) 15 (12 to 1) (9.0) 35 (30 to 40) 15 (12 to 1) (34 to 50) 22 (1 to 26) (43 to 65) 29 (24 to 34) (54 to 0) 35 (30 to 40) 22 2 (65 to ) 42 (34 to 50) (5 to 125) 54 (43 to 65) ( to 150) 67 (54 to 0) (120 to 10) 2 (65 to ) (50) 10 (140 to 220) 105 (5 to 125) (140 to 220) 105 (5 to 125) (60) 10 (140 to 220) 105 (5 to 125) (200 to 300) 125 ( to 150) (260 to 400) 150 (120 to 10) (260 to 400) 10 (140 to 220) (400 to 600) 250 (200 to 300) (400 to 600) 250 (200 to 300) (400 to 600) 250 (200 to 300) (520 to 00) 330 (260 to 400) (400 to 600) (520 to 00) T10 T12 T20 T20, T21 T25 T35 T50 T65 T0 T N125 N150 N10 N220 N300 N400 N600 N00 Notes 1: Heater designation is the model code which must be specified at time of order. 2: For choices of heater designation with voltage, motor capacity other than those shown above, refer to page. 3: N600/N00 should be used in combination with the TH-N600 a transformer (Mitsubishi CW-model) sold separately. 4: The figures in brackets ( ) for motor capacity indicate special capacity. T10 T12 T20, T21 T25 T35 Magnetic Contactors frame T50 T65 T0 T N125 N150 N10 N220 N300 N400 N600 N00 Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor dapplied to stard single phase (1 φ) motor Indicates the frame of an magnetic starter that is applicable to a heater designation of a thermal relay used in a single phase motor. Motor capacity [kw] Heater designation [A] (setting range) to 110V 200 to 220V Magnetic Contactors frame Heater designation [A] (setting range) (1.4 to 2) 0.9 (0.7 to 1.1) (2 to 3) 1.3 (1 to 1.6) (2. to 4.4) 1.7 (1.4 to 2) (4 to 6) 2.5 (2 to 3) (4 to 6) 2.5 (2 to 3) (5.2 to ) 3.6 (2. to 4.4) (5.2 to ) 3.6 (2. to 4.4) (7 to 11) 5 (4 to 6) (9 to 13) 5 (4 to 6) (12 to 1) 6.6 (5.2 to ) T10 Notes 1: Heater designation is the model code which must be specified at time of order. 2: For choices of heater designation with voltage, motor capacity other than those shown above, refer to page. 3: In the case of the enclosed models (MS-T12 model), the applicable capacity of the to 110V motors is 0.4kW. T12 T20, T21 T25 T35 T10 Magnetic Contactors frame T12 T20, T21 T25 T35 Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit

210 Magnetic Contactor Starters Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Thermal Relay Heater Designation Selection Table Thermal relay heater designation selection table The table below shows a general guidance to select a thermal relay. Voltage 3 phase motor Single phase motor Voltage Motor Motor capacity 200 to 220V 230 to 240V 346 to 350V 30V 400 to 440V 460 to 500V 550 to 600V 660V to 110V 115 to 120V 200 to 220V 230 to 240V capacity [kw] [kw] to A 0.35A 0.35A 0.5A 0.5A 0.7A 0.7A 0.24A 0.24A 0.35A 0.35A 0.5A 0.7A 0.7A 0.24A 0.24A 0.35A 0.35A 0.35A 0.35A 0.24A 0.24A 0.24A 0.35A 0.35A 0.35A 0.24A 0.24A 0.35A 0.35A 0.35A 0.24A 0.24A 0.24A 0.35A 0.24A 0.24A 1.7A 2.5A 3.6A 0.9A 1.3A 1.7A to A 0.7A 0.5A 0.5A 0.5A 0.35A 0.24A 3.6A 2.1A A 0.9A 0.7A 0.7A 0.5A 0.5A 0.35A 5A 2.5A A 0.9A 0.7A 0.7A 0.7A 0.5A 0.5A 5A 5A 2.5A to to to to to to to A 1.7A 1.7A 2.1A 2.5A 3.6A 5A 5A 6.6A 6.6A 9A 11A 15A 22A 29A 35A 42A 54A 67A 2A 2A 105A 125A 150A 10A 250A 330A 330A 500A 500A 660A 660A 660A 0.9A 1.3A 1.3A 2.1A 2.5A 3.6A 5A 5A 5A 6.6A 9A 11A 15A 22A 29A 29A 42A 54A 67A 2A 2A 105A 125A 150A 10A 250A 330A 330A 500A 500A 500A 660A 660A 0.7A 0.9A 0.9A 1.3A 1.7A 2.1A 2.5A 3.6A 3.6A 3.6A 5A 6.6A 9A 15A 15A 22A 22A 35A 42A 54A 54A 67A 2A 105A 125A 150A 10A 250A 250A 330A 330A 500A 500A 500A 660A 0.7A 0.9A 0.9A 1.3A 1.7A 2.1A 2.5A 2.5A 3.6A 3.6A 5A 6.6A 9A 11A 15A 22A 22A 29A 35A 42A 54A 54A 67A 2A 105A 125A 150A 10A 250A 250A 330A 330A 500A 500A 500A 660A 0.7A 0.7A 0.9A 1.3A 1.3A 1.7A 2.5A 2.5A 2.5A 3.6A 5A 6.6A 6.6A 11A 15A 15A 22A 29A 35A 42A 54A 54A 67A 2A 105A 125A 150A 10A 250A 250A 330A 330A 500A 500A 500A 660A 0.7A 0.7A 0.9A 0.9A 1.3A 1.7A 2.1A 2.1A 2.5A 2.5A 3.6A 5A 6.6A 9A 11A 15A 22A 22A 29A 35A 35A 42A 54A 67A 2A 105A 125A 150A 10A 250A 250A 330A 330A 330A 500A 500A 0.5A 0.5A 0.7A 0.7A 0.9A 1.3A 1.7A 1.7A 2.1A 2.5A 3.6A 5A 5A 9A 9A 11A 15A 22A 22A 29A 35A 42A 54A 54A 67A 105A 105A 125A 150A 10A 250A 250A 250A 330A 330A 500A 1.3A 1.7A 1.7A 2.1A 2.1A 3.6A 3.6A 5A 6.6A 9A 11A 15A 15A 22A 22A 29A 35A 42A 54A 67A 2A 105A 105A 150A 10A 10A 10A 250A 250A 330A 500A 5A 6.6A 6.6A 9A 11A 15A 22A 29A 6.6A 9A 11A 15A 22A 22A 35A 54A 2A 105A 2.5A 3.6A 3.6A 5A 5A 6.6A 9A 15A 3.6A 5A 6.6A 9A 9A 11A 15A 29A 42A 54A to to to to to to to 400 Notes 1: When ordering based on motor capacity, use this table to determine the heater designation for the thermal relay. Please accurately specify the voltage capacity. 2: Where the number of poles on the three phase motor is different, or in the case of a special generator, the full load current values may be different. In that case, specify the heater designation after checking the full load current of the motor. 3: As for a single phased motor, the full load current values may be different depending on its mode of startup operation. Therefore, the table above should be used as a guideline, the full load current should be checked in actual use when determining an appropriate heater designation. In the case of a single phase motor, please connect the motor as shown in the diagram below. With 2 elements With 3 elements Solid State Contactors Motor Circuit MC THR MC THR M M Connecting the thermal relay to a single phase motor

211 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Model name Main contact rating Auxiliary contact rating Performance Characteristic Outside dimensions Model names of attachable options (Note 9) Magnetic Starters/Magnetic Contactors Frame T10 T12 T20 T21 T25 T32 T35 T50 T65 T0 T Applicable stard IEC , EN , GB1404.4, JIS C Magnetic Contactors Non-Reversing S-T10 S-T12 S-T20 S-T21 S-T25 S-T32 S-T35 S-T50 S-T65 S-T0 S-T (Without Thermal Overload Relays, Open type) Reversing S-2 T10 S-2 T12 S-2 T20 S-2 T21 S-2 T25 S-2 T32 S-2 T35 S-2 T50 S-2 T65 S-2 T0 S-2 T Magnetic Starters Non-Reversing MSO-T10 MSO-T12 MSO-T20 MSO-T21 MSO-T25 MSO-T35 MSO-T50 MSO-T65 MSO-T0 MSO-T (With stard Open type Reversing MSO-2 T10 MSO-2 T12 MSO-2 T20 MSO-2 T21 MSO-2 T25 MSO-2 T35 MSO-2 T50 MSO-2 T65 MSO-2 T0 MSO-2 T 2-element, With Thermal Overload Enclosed Non-Reversing MS-T10 MS-T12 MS-T21 MS-T35 MS-T50 MS-T65 MS-T0 MS-T Relays) Reversing MS-2 T21 MS-2 T35 MS-2 T50 MS-2 T65 MS-2 T0 MS-2 T Combined Thermal Overload Relays TH-T1 TH-T25 TH-T25/T50 TH-T25/T50 TH-T65 TH-T65/T TH-T65/T Magnetic Starters Non-Reversing MSO-T10KP MSO-T12KP MSO-T20KP MSO-T21KP MSO-T25KP MSO-T35KP MSO-T50KP MSO-T65KP MSO-T0KP MSO-TKP (With Open type 3-element(2E), With Thermal Overload Relays) Reversing MSO-2 T10KP MSO-2 T12KP MSO-2 T20KP MSO-2 T21KP MSO-2 T25KP MSO-2 T35KP MSO-2 T50KP MSO-2 T65KP MSO-2 T0KP MSO-2 TKP Combined Thermal Overload Relays TH-T1KP TH-T25KP TH-T25/T50KP TH-T25/T50KP TH-T65KP TH-T65/TKP TH-T65/TKP Rated insulation voltage [V] 690 Rated impulse withst voltage [kv] 6 Rated frequency [Hz] 50/60 Pollution degree to 240VAC 2.5/11 [2.2/11] 3.5/13 [2.7/13] 4.5/1 [3.7/1] 5.5/25 [4/20] 7.5/30(26) [5.5/26] 7.5/32 [7.5/32] 11/40 [7.5/35] 15/55 [11/50] 1.5/65 [15/65] 22/5 [19/0] 30/105 [22/] Rated operational current / power Category AC-3 30 to 440VAC 4/9 [2.7/7] 5.5/12 [4/9] 7.5/1 [7.5/1] 11/23 [7.5/20] 15/30(26) [11/25] 15/32 [15/32] 1.5/40 [15/32] 22/4 [22/4] 30/65 [30/65] 45/5 [37/0] 55/105 [45/93] (Three-phase squirrel-cage motor load 500VAC 4/7 [2.7/6] 5.5/9 [5.5/9] 7.5/17 [7.5/17] 11/17 [7.5/17] 15/24 [11/20] 15/24 [11/20] 1.5/32 [15/26] 25/3 [22/3] 37/60 [30/45] 45/75 [45/75] 55/5 [45/75] stard responsibility) (Note 1) [kw/a] 690VAC 4/5 5.5/7 7.5/9 7.5/9 11/12 11/12 15/17 22/26 30/3 45/52 55/65 Rated operational current / power Category 200 to 220VAC 1.5/ 2.2/11 3.7/1 4.5/20 5.5/26 5.5/26 7.5/35 11/50 15/65 19/0 AC-4 (Three-phase squirrel-cage motor load 30 to 440VAC 2.2/6 4/9 5.5/13 7.5/17 11/24 11/24 15/32 22/47 30/62 37/75 inching responsibility) [kw/a] 500 to 550VAC 2.7/6 5.5/9 5.5/10 7.5/12 7.5/13 11/17 15/24 22/3 30/45 37/55 Single-phase motor maximum applicable load/ to 110VAC 0.4/ / /1 0.9/1(20) 1.2/26 1.5/32 1.7/34(35) maximum capacity (Category AC-3) [kw/a] 200 to 220VAC 0./11 1.0/13 1.5/1 1./1(20) Rated operational current / power Category to 220VAC AC-1 (Resistance, heater load) 30 to 440VAC Conventional free air thermal current Ith [A] Stard accessory Non-Reversing 1a 1a1b 2a2b 2a2b 2a2b 2a2b 2a2b 2a2b (Note 5) Reversing (Note 6, Note ) 1a 2+2b 1a1b 2+2b 2a2b 2 2a2b 2 2a2b 2 2a2b 2 2a2b 2 2a2b 2 2a2b 2 Contact arrangement Max. number of Non-Reversing additional options (Note 7) Reversing (Note 6, Note ) One optional UT-AX2 or UT-AX4 up to two optional UT-AX11 can be added. Up to two optional UT-AX2, UT-AX4, or UT-AX11 can be added. Up to two optional UT-AX2, UT- AX4, or UT-AX11 can be added. One optional UN-AX2 or UN-AX4 up to two optional UN-AX11 can be added. Up to two optional UN-AX2, UN- AX4, or UN-AX11 can be added. Rated operational current to 120VAC (Category AC-15 : Alternating current coil load) [A] 200 to 240VAC Conventional free air thermal current Ith [A] Mechanical durability [ten thous times] Category AC (Note 4) 200 Electrical durability [ten thous times] Category AC-4 3 (Note 4) Category AC-1 50 Category AC Switching frequency [time/hour] Category AC Category AC Sealed [VA] Coil consumption [VA] Inrush [VA] Magnetic Contactors (without Thermal Overload Relays) Non-Reversing (Width Height Depth) [mm] Reversing Open type Magnetic Starters Non-Reversing (Width Height Depth) [mm] Reversing (Contact structure 1a1b) UT-AX2/AX11 UN-AX2/AX11 UN-AX0 Auxiliary contact blocks (Contact structure 2a2b) UT-AX4 UN-AX4 With contact for low level signals UN-LL22 (Varistor) (Note 2) UT-SA21 Operation coil surge (Varistor + LED display) UT-SA22 absorber unit (Note 3) (CR) UT-SA23 (Varistor + CR) UT-SA25 TRIAC output UT-SY21 UN-SY31 DC/AC interface Contact output UT-SY22 UN-SY32 Charging part protection cover For Electromagnetic Starters For Electromagnetic Contactors Non-Reversing UN-CZ500+UN-CZ501 UN-CZ00+ UN-CZ01 Reversing UN-CZ504 UN-CZ04 Non-Reversing UN-CZ500 2 UN-CZ00 2 Reversing UN-CZ502 UN-CZ02 For Magnetic Starters (non-reversing) (Stard accessory) UT-CW00+UT-CW655 Terminal cover For Magnetic Contactors (non-reversing) (Stard accessory) UT-CW00 Mechanical interlocks UT-ML11 UN-ML21 UN-ML0 Notes 1: The figure inside the brackets ( ) for rated operating current is applicable to magnetic contactors (without thermal relays). The figure inside the brackets ( ) for motor capacity is applicable to enclosed magnetic starters. 2: We can also manufacture coil surge absorption built-in models (-SA models) for alternating current operated types T10 to T50 direct current operated types T12 to T50. 3: The T65 to N00 alternating current operating coils incorporate surge absorption function, so that a surge absorption unit for the coil is not required because coil switching surges do not occur. 4: 1,000,000 times for T20 AC-3 Class 30V or higher, 15,000 times for T35 to N00 AC-4 Class 30V or higher. 5: The auxiliary contact structures for mechanical latch delayed release models are different. For details of mechanical latch models, refer to page 79. 6: +2b of T10 to T20 auxiliary contact arrangements in Reversing type represents b contact built in the UN-ML11 interlock unit. 7: The main unit the auxiliary contact units need to be attached by customers as separate processes. The auxiliary contact unit for sealed models, the head on auxiliary contact for mechanical latched models, cannot be attached as additions. For details of the auxiliary contact unit, refer to pages 90. : For auxiliary contact arrangement in Reversing type, 2 is displayed as combined auxiliary contact arrangement of two Magnetic Contactors. Please specify the contact arrangement for which two main units are combined must be designated. <Designation example> In case of 1b 2 + 2b: 2B 9: In the case of using an option as an applied product, be aware that some options are unable to be attached. For details of combinations, refer to pages 90 to : The figure in the square brackets indicates the rated current shown on the rating plate of the product at which the category AC-3 opening/closing durability is 2,000,000 times (1,000,000 times for the T20 30V). Refer to the electric durability curve for the life performance. 4a4b 3a3b 2 Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit

212 72 Magnetic Contactor Starters Magnetic Starter/Contactor Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit Model name Main contact rating Auxiliary contact rating Performance Characteristic Outside dimensions Model names of attachable options (Note 9) Frame N125 N150 N10 N220 N300 N400 N600 N00 Applicable stard IEC ,EN ,GB1404.4, JIS C Magnetic Contactors Non-Reversing S-N125 S-N150 S-N10 S-N220 S-N300 S-N400 S-N600 S-N00 (Without Thermal Overload Relays, Open type) Reversing S-2 N125 S-2 N150 S-2 N10 S-2 N220 S-2 N300 S-2 N400 S-2 N600 S-2 N00 Magnetic Starters Non-Reversing MSO-N125 MSO-N150 MSO-N10 MSO-N220 MSO-N300 MSO-N400 (With stard Open type Reversing MSO-2 N125 MSO-2 N150 MSO-2 N10 MSO-2 N220 MSO-2 N300 MSO-2 N400 2-element, With Thermal Overload Enclosed Non-Reversing MS-N125 MS-N150 MS-N10 MS-N220 MS-N300 MS-N400 Relays) Reversing MS-2 N125 MS-2 N150 MS-2 N10 MS-2 N220 MS-2 N300 MS-2 N400 Combined Thermal Overload Relays TH-N120(TA) TH-N120(TA) TH-N220RH TH-N220RH TH-N400RH TH-N400RH TH-N600(+CT) TH-N600(+CT) Magnetic Starters Non-Reversing MSO-N125KP MSO-N150KP MSO-N10KP MSO-N220KP MSO-N300KP MSO-N400KP (With Open type 3-element(2E), With Thermal Overload Relays) Reversing MSO-2 N125KP MSO-2 N150KP MSO-2 N10KP MSO-2 N220KP MSO-2 N300KP MSO-2 N400KP Combined Thermal Overload Relays TH-N120(TA)KP TH-N120(TA)KP TH-N220RHKP TH-N220RHKP TH-N400RHKP TH-K400RHKP TH-N600KP(+CT) TH-N600KP(+CT) Rated insulation voltage [V] 690 Rated impulse withst voltage [kv] 6 Rated frequency [Hz] 50/60 Pollution degree to 240VAC 30/125 37/150 45/10 55/220 75/ / / /00 Rated operational current / power Category AC-3 30 to 440VAC 60/120 75/150 90/10 110/ / / / /00 (Three-phase squirrel-cage motor load 500VAC 60/90 90/ /10 132/ / / / /720 stard responsibility) (Note 1) [kw/a] 690VAC Rated operational current / power Category 200 to 220VAC 22/93 30/125 37/150 45/10 55/220 75/ / /630 AC-4 (Three-phase squirrel-cage motor load 30 to 440VAC 45/90 55/110 75/150 90/10 110/ / / /630 inching responsibility) [kw/a] 500 to 550VAC 45/65 55/0 75/140 90/ / / / /500 Single-phase motor maximum applicable load/ to 110VAC maximum capacity (Category AC-3) [kw/a] 200 to 220VAC Rated operational current / power Category to 220VAC AC-1 (Resistance, heater load) 30 to 440VAC Conventional free air thermal current Ith [A] Stard accessory Non-Reversing 2a2b 2a2b 2a2b 2a2b 2a2b 2a2b 2a2b 2a2b (Note 5) Reversing (Note 6, Note ) 2a2b 2 3a3b 2 3a3b 2 3a3b 2 3a3b 2 3a3b 2 4a4b 2 4a4b 2 Contact arrangement Max. number of Non-Reversing 4a4b 4a4b 4a4b 4a4b 4a4b 4a4b 4a4b 4a4b additional options Reversing (Note 7) (Note 6, Note ) 3a3b 2 Rated operational current to 120VAC (Category AC-15 : Alternating current coil load) [A] 200 to 240VAC Conventional free air thermal current Ith [A] Mechanical durability [ten thous times] 500 Category AC-3 50 Electrical durability [ten thous times] Category AC-4 3 (Note 4) Category AC-1 50 Category AC Switching frequency [time/hour] Category AC Category AC Sealed [VA] Coil consumption [VA] Inrush [VA] Magnetic Contactors (without Thermal Overload Relays) Non-Reversing (Width Height Depth) [mm] Reversing Open type Magnetic Starters Non-Reversing (Width Height Depth) [mm] Reversing (Contact structure 1a1b) UN-AX0 UN-AX150 Auxiliary contact blocks (Contact structure 2a2b) UN-AX600 With contact for low level signals (Varistor) (Note 2) Operation coil surge (Varistor + LED display) absorber unit (Note 3) (CR) (Varistor + CR) TRIAC output DC/AC interface Contact output Charging part protection cover For Electromagnetic Starters For Electromagnetic Contactors Non-Reversing UN-CZ1250+ UN-CZ1251 UN-CZ1500+ UN-CZ1501 UN-CZ2200+UN-CZ2201 UN-CZ3000+UN-CZ3001 Reversing UN-CZ1254 UN-CZ1504 UN-CZ2204 UN-CZ3004 Non-Reversing UN-CZ UN-CZ UN-CZ UN-CZ Reversing UN-CZ1252 UN-CZ1502 UN-CZ2202 UN-CZ3002 For Magnetic Starters (non-reversing) Terminal cover For Magnetic Contactors (non-reversing) Mechanical interlocks UN-ML0 UN-ML150 UN-ML220 Notes 1: The figure inside the brackets ( ) for rated operating current is applicable to magnetic contactors (without thermal relays). The figure inside the brackets ( ) for motor capacity is applicable to enclosed magnetic starters. 2: We can also manufacture coil surge absorption built-in models (-SA models) for alternating current operated types T10 to T50 direct current operated types T12 to T50. 3: The T65 to N00 alternating current operating coils incorporate surge absorption function, so that a surge absorption unit for the coil is not required because coil switching surges do not occur. 4: 1,000,000 times for T20 AC-3 Class 30V or higher, 15,000 times for T35 to N00 AC-4 Class 30V or higher. 5: The auxiliary contact structures for mechanical latch delayed release models are different. For details of mechanical latch models, refer to page 79. 6: +2b of T10 to T20 auxiliary contact arrangements in Reversing type represents b contact built in the UN-ML11 interlock unit. 7: The main unit the auxiliary contact units need to be attached by customers as separate processes. The auxiliary contact unit for sealed models, the head on auxiliary contact for mechanical latched models, cannot be attached as additions. For details of the auxiliary contact unit, refer to pages 90. : For auxiliary contact arrangement in Reversing type, 2 is displayed as combined auxiliary contact arrangement of two Magnetic Contactors. Please specify the contact arrangement for which two main units are combined must be designated. <Designation example> In case of 1b 2 + 2b: 2B 9: In the case of using an option as an applied product, be aware that some options are unable to be attached. For details of combinations, refer to pages 90 to 91.

213 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Magnetic Starters MS-T series (non-reversing) : Enclosed MS-2xT series (Reversing) : Enclosed Model name Rated capacity (kw) Category AC-3 (Note 1) Heater rating (designation) of stard Thermal Overload Relays (A) Auxiliary contact arrangement MSO-T10 Non-reversing MS-T10 MS-T12 MS-T21 MS-T25 MS-T35 MS-T50 MS-T65 MS-T0 MS-T Reversing MS-2XT21 MS-2XT25 MS-2XT35 MS-2XT50 MS-2XT65 MS-2XT0 MS-2XT 220 to 240VAC 2.5[2.2] 3.5[2.7] 5.5[4] 7.5[5.5] 11[7.5] 15[11] 1.5[15] 22[19] 30[22] 30 to 440VAC 4[2.7] 5.5[4] 11[7.5] 15[11] 1.5[15] 22[22] 30[30] 45[37] 55[45] 500VAC 4[2.7] 5.5[5.5] 11[7.5] 15[11] 1.5[15] 22[22] 37[30] 45[45] 55[45] Operation coil rating Refer to page 76 Non- Reversing Reversing (unit: mm) Non-reversing Reversing Stard 1a 1a1b 2a2b Special 1b 2a Stard 2a2bx2 Special A B C A B C Note 1: The figure in the square brackets indicates the rated current shown on the rating plate of the product at which the category AC-3 opening/closing durability is 2,000,000 times (1,000,000 times for the T20 30V). Refer to the electric durability curve for the life performance. Features/ Summary List Produced Models Selections Order Procedure MSO-T series (non-reversing) : Open type MSO-2xT series (Reversing) : Open type Model name Rated capacity (kw) Category AC-3 (Note 1) Heater rating (designation) of stard Thermal Overload Relays (A) Auxiliary contact arrangement Non-Reversing MSO-T10 MSO(D)-T12 MSO(D)-T20 MSO(D)-T21 MSO-T25 Reversing MSO-2 T10 MSO(D)-2 T12 MSO(D)-2 T20 MSO(D)-2 T21 MSO-2 T to 240VAC 2.5[2.2] 3.5[2.7] 4.5[3.7] 5.5[4] 7.5[5.5] 30 to 440VAC 4[2.7] 5.5[4] 7.5[7.5] 11[7.5] 15[11] 500VAC 4[2.7] 5.5[5.5] 7.5[7.5] 11[7.5] 15[11] Operation coil rating Refer to pages 76 Non- Reversing Reversing (unit: mm) Non-Reversing Reversing IEC 35mm rail mounting type Front clip-on auxiliary contact block mounting type Option Side clip-on auxiliary contact block mounting type Surge absorber mounting type Stard 1a 1a1b 1a1b 2a2b 2a2b Special 1b 2a 2a Stard 1a 2+2b 1a1b 2+2b 1a1b 2+2b 2a2b 2 2a2b 2 Special 1b 2+2b 2a 2+2b 2a 2+2b A B C 79 79(101) 79(101) 2(109) 2 A B C 79 79(101) 79(101) 2(115) 2 Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit Note 1: The figure in the square brackets indicates the rated current shown on the rating plate of the product at which the category AC-3 opening/closing durability is 2,000,000 times (1,000,000 times for the T20 30V). Refer to the electric durability curve for the life performance.

214 74 Magnetic Contactor Starters Magnetic Starter/Contactor Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit MSO-T series (non-reversing) : Open type MSO-2xT series (Reversing) : Open type Model name Rated capacity (kw) Category AC-3 (Note 1) Heater rating (designation) of stard Thermal Overload Relays (A) Non-Reversing MSO(D)-T35 MSO(D)-T50 MSO(D)-T65 MSO(D)-T0 MSO(D)-T Reversing MSO(D)-2 T35 MSO(D)-2 T50 MSO(D)-2 T65 MSO(D)-2 T0 MSO(D)-2 T 220 to 240VAC 11[7.5] 15[11] 1.5[15] 22[19] 30[22] 30 to 440VAC 1.5[15] 22[22] 30[30] 45[37] 55[45] 500VAC 1.5[15] 22[22] 37[30] 45[45] 55[45] Operation coil rating Refer to pages 76 Non- Stard 2a2b 2a2b 2a2b 2a2b 2a2b Auxiliary contact Reversing Special arrangement Stard 2a2b 2 2a2b 2 2a2b 2 2a2b 2 2a2b 2 Reversing Special (unit: mm) Non-Reversing Reversing A (160) 174.5(176.5) 196(206) B C 91(123) 106(133) 106(133) 127(157) A B C 97(129) 112(139) 112(139) 137(167) IEC 35mm rail mounting type Front clip-on auxiliary contact block mounting type Option Side clip-on auxiliary contact block mounting type Surge absorber mounting type Note 1: The figure in the square brackets indicates the rated current shown on the rating plate of the product at which the category AC-3 opening/closing durability is 2,000,000 times (1,000,000 times for the T20 30V). Refer to the electric durability curve for the life performance. Thermal Overload Relays configuring the Magnetic Starters Thermal Overload Relays models heater types that configure Magnetic Starters Magnetic Contactors frame Thermal Overload Relays model Heater designation (adjustable range of stabilized current) (A) T10, T12, T20 TH-T1 0.12(0.1 to 0.16), 0.17(0.14 to 0.22), 0.24(0.2 to 0.32), 0.35(0.2 to 0.42), 0.5(0.4 to 0.6), 0.7(0.55 to 0.5), 0.9(0.7 to 0.1), 1.3(1 to 1.6), 1.7(1.4 to 2), 2.1(1.7 to 2.5), 2.5(2 to 3), 3.6(2. to 4.4), 5(4 to 6), 6.6(5.2 to ), 9(7 to 11), 11(9 to 13)*, 15(12 to 1)* T21, T25 TH-T25 (Note 3) 0.24(0.2 to 0.32), 0.35(0.2 to 0.42), 0.5(0.4 to 0.6), 0.7(0.55 to 0.5), 0.9(0.7 to 1.1), 1.3(1 to 1.6), 1.7(1.4 to 2), 2.1(1.7 to 2.5), 2.5(2 to 3), 3.6(2. to 4.4), 5(4 to 6), 6.6(5.2 to ), 9(7 to 11), 11(9 to 13), 15(12 to 1), 22(1 to 26)* 0.24 (0.2 to 0.32), 0.35 (0.2 to 0.42), 0.5 (0.4 to 0.6), 0.7 (0.55 to 0.5), 0.9 (0.7 to 1.1), 1.3 (1 to 1.6), 1.7 (1.4 to 2), 2.1 (1.7 to 2.5), TH-T25 T (2 to 3), 3.6 (2. to 4.4), 5 (4 to 6), 6.6 (5.2 to ), 9 (7 to 11), 11 (9 to 13), 15 (12 to 1), 22 (1 to 26) TH-T50 29 (24 to 34) 0.24 (0.2 to 0.32), 0.35 (0.2 to 0.42), 0.5 (0.4 to 0.6), 0.7 (0.55 to 0.5), 0.9 (0.7 to 1.1), 1.3 (1 to 1.6), 1.7 (1.4 to 2), 2.1 (1.7 to 2.5), TH-T25 T (2 to 3), 3.6 (2. to 4.4), 5 (4 to 6), 6.6 (5.2 to ), 9 (7 to 11), 11 (9 to 13), 15 (12 to 1), 22 (1 to 26) TH-T50 29 (24 to 34), 35 (30 to 40), 42 (34 to 50) T65 TH-T65 15 (12 to 1), 22 (1 to 26), 29 (24 to 34), 35 (30 to 40), 42 (34 to 50), 54 (43 to 65) Solid State Contactors Motor Circuit TH-T65 15 (12 to 1), 22 (1 to 26), 29 (24 to 34), 35 (30 to 40), 42 (34 to 50), 54 (43 to 65) T0 TH-T 67 (54 to 0) TH-T65 15 (12 to 1), 22 (1 to 26), 29 (24 to 34), 35 (30 to 40), 42 (34 to 50), 54 (43 to 65) T TH-T 67 (54 to 0), 2 (65 to ) Notes 1: Select the value closer to the heater designation if the stabilized current has two values. 2: Heater designation marked with * has Magnetic Starters frames that cannot be applied. For information on the applicable Magnetic Starters frames, refer to the "Heater rating (designation) of stard Thermal Overload Relays" field in the above table. 3: The connection conductor kit UN-TH21 is required to use in combination with the Magnetic Contactor to make a Magnetic Starters.

215 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Magnetic Contactors S-T series (non-reversing) S-2xT series (Reversing) Model name Rated operational current (A) Category AC-3 (Note 1, 2) Non-Reversing S-T10 S(D)-T12 S(D)-T20 S(D)-T21 S-T25 S(D)-T32 Reversing S-2 T10 S(D)-2 T12 S(D)-2 T20 S(D)-2 T21 S-2 T25 S(D)-2 T to 240VAC 11[11] 13[13] 1[1] 25[20] 30(26)[26] 32[32] 30 to 440VAC 9[7] 12[9] 1[1] 23[20] 30(26)[25] 32[32] 500VAC 7[6] 9[9] 17[17] 17[17] 24[20] 24[20] Conventional free air thermal current Ith (A) Auxiliary contact arrangement Option Operation coil rating Refer to pages 76 Non- Reversing Reversing (unit: mm) Non-Reversing Reversing IEC 35mm rail mounting type Front clip-on auxiliary contact block mounting type Side clip-on auxiliary contact block mounting type Surge absorber mounting type Stard 1a 1a1b 1a1b 2a2b 2a2b Special 1b 2a 2a Stard 1a 2+2b 1a1b 2+2b 1a1b 2+2b 2a2b 2 2a2b 2 Special 1b 2+2b 2b 2+2b 2b 2+2b A B C 7 7() 7() 1(10) 1 1(10) A B C 7 7() 7() 1(114) 1 111(13) Notes 1: The figure in the square brackets indicates the rated current shown on the rating plate of the product at which the category AC-3 opening/closing durability is 2,000,000 times (1,000,000 times for the T20 30V). Refer to the electric durability curve for the life performance. 2: The content within ( ) of rated capacity rated operational current is applied to the Magnetic Contactor. Model name Rated operational current (A) Category AC-3 (Note 1) Non-Reversing S(D)-T35 S(D)-T50 S(D)-T65 S(D)-T0 S(D)-T Reversing S(D)-2 T35 S(D)-2 T50 S(D)-2 T65 S(D)-2 T0 S(D)-2 T 220 to 240VAC 40[35] 55[50] 65[65] 5[0] 105[] 30 to 440VAC 40[32] 50[50] 65[65] 5[0] 105[93] 500VAC 32[26] 3[3] 60[45] 75[75] 5[75] Conventional free air thermal current Ith (A) Auxiliary contact arrangement Option Operation coil rating Refer to pages 76 Non- Reversing Reversing (unit: mm) Non-Reversing Reversing Stard 2a2b 2a2b 2a2b 2a2b 2a2b Special Stard 2a2b 2 2a2b 2 2a2b 2 2a2b 2 2a2b 2 Special A (134) B 75 C 91(123) 106(133) 127(157) A (147) B C 97(129) 112(139) 137(167) IEC 35mm rail mounting type Front clip-on auxiliary contact block mounting type Side clip-on auxiliary contact block mounting type Surge absorber mounting type Note 1: The figure in the square brackets indicates the rated current shown on the rating plate of the product at which the category AC-3 opening/closing durability is 2,000,000 times (1,000,000 times for the T20 30V). Refer to the electric durability curve for the life performance. S-T10 Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit

216 76 Magnetic Contactor Starters Magnetic Starter/Contactor Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Open Model Magnetic Starters MSO-N series (non-reversing) : Open type MSO-2xN series (Reversing) : Open type Non-Reversing Reversing 220 to 240VAC 30 to 440VAC 500VAC Heater rating (designation) of stard Thermal Overload Relays (A) Auxiliary contact arrangement B Model name Rated capacity (kw) Category AC-3 Option A Special Special specification thermal relay C Operation coil rating Non-Reversing Reversing Non-Reversing Reversing A B C Product weight [kg] Product weight [kg] IEC 35mm rail mounting type Front clip-on auxiliary contact block mounting type Side clip-on auxiliary contact block mounting type Surge absorber mounting type Reversing mechanical interlock attachment Anti-corrosion treatment Delay open type Quick response model (with 2E) Saturated reactor attached With 2E (3 elements) Stard Special Stard Special A B C MSO-YS MSO-DL MSO-KF MSO-SR MSO-KP Notes 1: *MSO-2xN1 model has auxiliary contacts (head on unit) as a stard attachment. 2: "CX" of the model name refers to the CAN terminal attachments. 3: The** mark means that CAN terminal attachments cannot be manufactured for this model. MSO-N125 MSO-2 N a2b - 2a2b MSO-N150 MSO-N220 MSO-N150 MSO-N10 MSO-N220 MSO-2 N150 MSO-2 N10 MSO-2 N Refer to the table below 2a2b - 3a3b 2-2a2b - 3a3b 2-2a2b - 3a3b MSO-N300 MSO-2 N a2b 2a2b - - 3a3b 2 3a3b General purpose coil models contain a surge absorber Delivery date category Stard item Substard item Special Item - MSO-N400 MSO-2 N Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit Thermal relay combined with an magnetic starter Model names types of heaters for thermal relays that can be combined with magnetic starters Magnetic Contactors frame N125, N150 N10, N220 N300, N400 N600, N00 Thermal Overload Relays model TH-N120(KP) TH-N120TA(KP) TH-N220RH(KP) TH-N400RH(KP) TH-N600(KP) Heater designation (adjustable range of stabilized current) (A) 42(34 to 50), 54(43 to 65), 67(54 to 0), 2(65 to ) 105(5 to 125), 125( to 150)* 2(65 to ), 105(5 to 125), 125( to 150), 150(120 to 10), 10(140 to 220)* 105(5 to 125), 125( to 125), 150(120 to 10), 10(140 to 220), 250(200 to 300), 330(260 to 400)* 250(200 to 300):400/5A, 330(260 to 400):500/5A, 500(400 to 600):750/5A, 660(520 to 00)*:0/5A Notes 1: Where the stabilized current value is between two heater designations, choose the heater designation to which the current value is closer. 2: Use the TH-N600 model thermal relay combined with the transformer (CW-15 model/15va by Mitsubishi Electric) whose current transformation ratio is shown in the table. 3: The N600 N00 models should be combined with the TH-N600. (An MSO model cannot be manufactured.) 4: "CX" of the model name refers to the CAN terminal attachments. 5: Heater designations with the *mark have magnetic starter frames to which they cannot be applied, so please refer to the heater rating (designation) column of the stard model thermal relay on the table above, for applicable magnetic starter frames. Coil Ratings Operating coil rating (Alternating current operate) for S-N125 to N00 Coil designation Ratings Coil designation Ratings Coil designation Ratings VAC 200VAC 127V 50Hz V 50Hz V 50Hz 300VAC 500VAC 127V 60Hz V 60Hz V 60Hz V 50Hz 30440V 50Hz (24VAC) 24V 50/60Hz 400VAC V 60Hz 30440V 60Hz (4VAC) 450V 50/60Hz Note 1: 24VAC cannot be manufactured for N10 to N00, 4VAC cannot be manufactured for N600 N00.

217 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Magnetic Contactors S-N series (non-reversing) S-2x series (Reversing) Model name Non-Reversing Reversing 220 to 240VAC 30 to 440VAC 500VAC Conventional free air thermal current Ith [A] Auxiliary contact arrangement B Option Rated capacity (kw) Category AC-3 A Operation Coil Ratings C Non- Reversing Reversing Non- Reversing Reversing IEC 35mm rail mounting type A B C Product weight [kg] A B C Product weight [kg] Front clip-on auxiliary contact block mounting type Side clip-on auxiliary contact block mounting type Surge absorber mounting type Stard Special Stard Special Reversing mechanical interlock attachment possible Special Anti-corrosion treatment S-YS Delay open type S-DL S-N125 S-2 N a2b 2a2b Notes 1: *S-2xN1 model has auxiliary contacts (head on unit) as a stard attachment. 2: "CX" of the model name refers to the CAN terminal attachments. 3: The** mark means that CAN terminal attachments cannot be manufactured for this model. S-N125 S-N150 S-2 N a2b 3a3b S-N10 S-N220 S-N300 S-N400 S-2 N10 S-2 N220 S-2 N300 S-2 N Refer to the table below 2a2b 3a3b 2 2a2b 3a3b 2 2a2b 3a3b 2 2a2b 3a3b S-N220 S-N600 Delivery date category Stard item Substard item Special Item S-N600 S-2 N a2b 2a2b 4a4b 2 4a4b S-N00 S-2 N Features/ Summary List Produced Models Selections Order Procedure Coil Ratings Operating coil rating (Alternating current operate) for S-N125 to N00 Coil designation Ratings Coil designation Ratings Coil designation Ratings VAC 200VAC 127V 50Hz V 50Hz V 50Hz 300VAC 500VAC 127V 60Hz V 60Hz V 60Hz V 50Hz V 50Hz (24VAC) 24V 50/60Hz 400VAC V 60Hz V 60Hz (4VAC) 4 50V 50/60Hz Note 1: 24VAC cannot be manufactured for N10 to N00, 4VAC cannot be manufactured for N600 N00. Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit

218 7 Magnetic Contactor Starters Magnetic Starter/Contactor Features/ Summary List Produced Models DC Operate magnetic Contactors SD-N series (non-reversing) SD-2xN series (Reversing) Non-Reversing Model name Reversing Rated capacity (kw) 200 to 220VAC Category AC-3 30 to 440VAC Conventional free air thermal current lth [A] Operating coil voltage (designation) Auxiliary contact arrangement Non-Reversing (Both stard special) Reversing A B C Non-Reversing B C Product weight [kg] A B Reversing C Product weight [kg] IEC 35mm rail mounting type A Motor Circuit Solid State Contactors Option Unit Contactor Relays Thermal Overload Relays Magnetic Starter/ Contactor Selections Order Procedure Notes 1: "CX" of the model name refers to the CAN terminal attachments. 2: Ratings with an * mark are for special products, rated at SD-N220 above. 3: 12VDC cannot be manufactured for SD-N600 N00. SD-N125 SD-2 N125 SD-N150 SD-2 N150 SD-N125 SD-N220 SD-N300 SD-2 N220 SD-2 N300 SD-N400 SD-2 N400 SD-N400 SD-N600 SD-2 N600 SD-N00 SD-2 N VDC, 24VDC*, 4V, V, 110V, 125V (120 to 125V), 200V, 220V [Figures in brackets ( ) indicates rated values] 2a2b 2a2b 2 2a2b 3a3b 2 2a2b 3a3b 2 2a2b 3a3b 2 2a2b 3a3b 2 2a2b 4a4b 2 2a2b 4a4b

219 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Magnetic Contactor with Mechanical Latch SL-T series (AC closing coil, non-reversing) SL-N series (AC closing coil, non-reversing) SLD-N series (DC closing coil, non-reversing) SL-2 N series (AC closing coil, reversing) SLD-2 N series (DC closing coil, reversing) Model name SL-T21(BC) Rated capacity (kw) Category AC to 220VAC 30 to 440VAC Conventional free air thermal current lth [A] Alternating current operate: V, 200V, 300V, 400V, 500V Operating coil voltage (designation) Direct current operate: 12VDC, 24VDC, 4VDC, V ( to 110V), 125V (120 to 125V), 200V (200 to 220V) [Figures in brackets ( ) indicate rated values] Auxiliary contact arrangement (Both stard special) Non-Reversing Reversing 2a2b 2a2b 1a2b 1a2b 2 1a2b 2a3b 2 1a2b 2a3b 2 1a2b 2a3b 2 1a2b 2a3b 2 1a2b 3a4b 2 1a2b 3a4b 2 B C A B C Product weight [kg] A B C Product weight [kg] IEC 35mm rail mounting type A Non-Reversing Reversing Non-Reversing Reversing Notes 1: Operating coils are rated for 15 minutes 2: "CX" of the model name refers to the CAN terminal attachments. 3: 12VDC cannot be manufactured for SD-N600 N00. SL -N125 SLD SL -2 N125 SLD SL -N150 SLD SL -2 N150 SLD SL -N220 SLD SL -2 N220 SLD SL -N300 SLD SL -2 N300 SLD SL -N400 SLD SL -2 N400 SLD SL -N600 SLD SL -2 N600 SLD SL -N00 SLD SL -2 N00 SLD Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit

220 0 Magnetic Contactor Starters Magnetic Starter/Contactor/Thermal Overload Relays DC Interface Contactors SD-Q, MSOD-Q series (Non-Reversing) SD-QR, MSOD-QR series (Reversing) Model name Type Magnetic Contactors SD- Magnetic Starters MSOD- Combined Thermal Overload Relays Model name Heater designation Applicable range [A] Non-Reversing Reversing Q11 Q12 QR11 QR12 Q11 Q12 QR11 QR12 TH-N12(KP) TH-N12(KP) 0.12 to 11 SD-Q to 11 Features/ Summary List Produced Models Selections Order Procedure Rated capacity (kw) 200 to 240V Category AC-3 30 to 440V Rated operational current (A) 200 to 240V Category AC-3 30 to 440V Conventional free air thermal current Ith [A] Stard Auxiliary contact arrangement Special B C IEC 35mm rail mounting type Coil Ratings a 1a1b 2b 2a2b 1b 2a VDC Motor Circuit Solid State Contactors Option Unit Contactor Relays Thermal Overload Relays Magnetic Starter/ Contactor Magnetic Contactors A Magnetic Starters A B C Product weight [kg] A B C Product weight [kg]

221 Low-Voltage Circuit P.664 Magnetic Contactor Starters P.50 1 Thermal Overload Relays Specification TH-T series Model name W H D Frame Appearance with 2-elements with 3-elements Outside dimensions [mm] W H D Product weight [kg] For Magnetic Starters For independent mounting For Magnetic Starters For independent mounting For Magnetic Starters For independent mounting For Magnetic Starters For independent mounting Applicable stard Ambient temperature [ C] Use condition Frequency [Hz] Rated insulation voltage [V] Rated impulse withst voltage [kv] Pollution degree T1 TH-T1 TH-T1KP T25 TH-T25 TH-T25KP IEC , EN , JIS C , GB to +40 (Stard: 20 C; maximum temperature on the board: 55 C) 0(DC) to Features/ Summary /Functions Operation circuit (contact) specifications Main circuit specifications Applied products Heater designation (adjustable range of stabilized current) [A] (Rated operational voltage : 550V maximum) Power consumption [VA/element] at minimum/maximum stabilization Terminal screw size Compatible with terminal Electric wire size [mm 2 ] Crimp lug size Contact arrangement Conventional free air thermal current Ith [A] Rating Category AC-15 AC operated Magnetic Contactors Coil opening closing a contact/b contact 24VAC 120VAC 240VAC Operational The value in brackets indicates the rating for automatic reset. 550VAC Current Category DC-13 24VDC DC operated Magnetic Contactors [A] Coil opening closing The value in brackets indicates the rating for automatic reset. 110VDC 220VDC Minimum applicable load level Terminal screw size Compatible with terminal Electric wire size [mm 2 ] Crimp lug size Trip class Operating characteristic curve description page Vibration resistance (vibration resistance malfunction performance) Trip-free Reset method Operation indication (lever indication) Manual trip check With saturable reactor With 3-element (2E) thermal saturable reactor 2-element quick-acting characteristics thermal With 3-element (2E) thermal quick-acting characteristics Notes 1: The ambient temperature compensator is mounted on all types. 2: The mark indicates stard equipment. TH-SR TH-KPSR TH-FS TH-FSKP 0.12 (0.1 to 0.16) 0.17 (0.14 to 0.22) 0.24 (0.2 to 0.32) 0.35 (0.2 to 0.42) 0.5 (0.4 to 0.6) 0.7 (0.55 to 0.5) 0.9 (0.7 to 1.1) 1.3 (1 to 1.6) 1.7 (1.4 to 2) 2.1 (1.7 to 2.5) 2.5 (2 to 3) 3.6 (2. to 4.4) 5 (4 to 6) 6.6 (5.2 to ) 9 (7 to 11) 11 (9 to 13) 15 (12 to 1) 0. / 1. M3.5 f1.6, 0.75 to to 2-3.5, 5.5-S3 1a1b 2 2(0.5) / 2(0.5) 2(0.5) / 2(0.5) 1(0.5) / 1(0.5) 0.3(0.3) / 0.3(0.3) 0.5(0.3) 0.2(0.2) 0.1(0.1) 20V 5mA M3.5 f1.6, 0.75 to to A Page 6 10 to 55 Hz, 19.6 m/s 2 Manual/Automatic switchable 0.24 (0.2 to 0.32) 0.35 (0.2 to 0.42) 0.5 (0.4 to 0.6) 0.7 (0.55 to 0.5) 0.9 (0.7 to 1.1) 1.3 (1 to 1.6) 1.7 (1.4 to 2) 2.1 (1.7 to 2.5) 1.5 / 3.0 M4 f1.6 to 2.6, 1.25 to to a1b 5 2(0.5) / 3(0.5) 2(0.5) / 3(0.5) 1(0.5) / 2(0.5) 0.3(0.3) / 0.3(0.3) 1(0.3) 0.2(0.2) 0.1(0.1) 20V 5mA M3.5 f1.6, 0.75 to to (2 to 3) 3.6 (2. to 4.4) 5 (4 to 6) 6.6 (5.2 to ) 9 (7 to 11) 11 (9 to 13) 15 (12 to 1) 22 (1 to 26) Manual/Automatic switchable List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit

222 2 Magnetic Contactor Starters Thermal Overload Relays Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors TH-T series Applied products /Functions Operation circuit (contact) specifications Main circuit specifications Model name W H D Frame Appearance with 2-elements with 3-elements Outside dimensions [mm] W H D Product weight [kg] For Magnetic Starters For independent mounting For Magnetic Starters For independent mounting For Magnetic Starters For independent mounting For Magnetic Starters For independent mounting Applicable stard Ambient temperature [ C] Use condition Frequency [Hz] Rated insulation voltage [V] Rated impulse withst voltage [kv] Pollution degree Heater designation (adjustable range of stabilized current) [A] (Rated operational voltage : 550V maximum) Power consumption [VA/element] at minimum/maximum stabilization Terminal screw size Compatible with terminal Electric wire size [mm 2 ] Crimp lug size Contact arrangement Conventional free air thermal current Ith [A] Category AC-15 24VAC AC operated Magnetic Contactors 120VAC Coil opening closing Rating a contact/b contact 240VAC Operational The value in brackets indicates the rating for automatic reset. 550VAC Current Category DC-13 24VDC DC operated Magnetic Contactors [A] 110VDC Coil opening closing The value in brackets indicates the rating for automatic reset. 220VDC Minimum applicable load level Terminal screw size Compatible with terminal Electric wire size [mm 2 ] Crimp lug size Trip class 15 to 42A:10 54A:10A Operating characteristic curve description page Page 6 Vibration resistance (vibration resistance malfunction performance) 10 to 55Hz 19.6m/s 2 Trip-free Reset method Manual/Automatic switchable Manual/Automatic switchable Operation indication (lever indication) Manual trip check With saturable reactor TH-SR (TH-T50SR) (TH-T65SR) With 3-element (2E) thermal saturable reactor TH-KPSR (TH-T50KPSR) (TH-T65KPSR) 2-element quick-acting characteristics thermal TH-FS (TH-T50FS) (TH-T65FS) With 3-element (2E) thermal quick-acting characteristics TH-FSKP (TH-T50FSKP) (TH-T65FSKP) Notes 1: The ambient temperature compensator is mounted on all types. 2: The mark indicates stard equipment, the indicates substard items. T50 TH-T50 TH-T50KP T65 T IEC , EN , JIS C , GB to +40 (Stard: 20 C; maximum temperature on the board: 55 C) 0(DC) to (24 to 34) 35 (30 to 40) 42 (34 to 50) 1.6/3.2 M5 f5.5 to to a1b 5 2(0.5) / 3(0.5) 2(0.5) / 3(0.5) 1(0.5) / 2(0.5) 0.3(0.3) / 0.3(0.3) 1(0.3) 0.2(0.2) 0.1(0.1) 20V 5mA M3.5 f1.6, 1.25 to to A Motor Circuit TH-T65 TH-T65KP (12 to 1) 22 (1 to 26) 29 (24 to 34) 35 (30 to 40) 42 (34 to 50) 54 (43 to 65) 2.4/5.5 M to a1b 5 2(0.5) / 3(0.5) 2(0.5) / 3(0.5) 1(0.5) / 2(0.5) 0.5(0.5) / 1(0.5) 1(0.3) 0.2(0.2) 0.1(0.1) 20V 5mA M4 f1.6, 1.25 to to 2-4, 5.5-S4 TH-T TH-TKP (54 to 0) 2 (65 to ) 2.5/6.0 M to 22-6, 3-S6 1a1b 5 2(0.5) / 3(0.5) 2(0.5) / 3(0.5) 1(0.5) / 2(0.5) 0.5(0.5) / 1(0.5) 1(0.3) 0.2(0.2) 0.1(0.1) 20V 5mA M4 f1.6, 1.25 to to 2-4, 5.5-S4 67A:10 2A:10A Manual/Automatic switchable (TH-TSR) (TH-TKPSR) (TH-TFS) (TH-TFSKP)

223 Low-Voltage Circuit P.664 Magnetic Contactor Starters P.50 3 TH-N series Option Applied product /Functions Operation circuit (contact) specifications Main circuit specifications Model name W H D Use condition Frame N120 N120TA N220 Appearance with 2-elements Applicable stard For Magnetic Starters For independent mounting with For Magnetic Starters 3-elements For independent mounting Outside dimensions [mm] For Magnetic Starters W H D For independent mounting Product weight For Magnetic Starters [kg] For independent mounting Ambient temperature [ C] Frequency [Hz] Heater designation (adjustable range of stabilized current) [A] (The dotted lines ( ) on the table to the right show the compatibility with the frames of magnetic contactors) (For heater designations of applied products, refer to the relevant portion of the main document) 42 (34 to 50) 54 (43 to 65) 67 (54 to 0) 2 (65 to ) TH-N120TA TH-N220RH TH-N120 TH-N120TAHZ TH-N220HZ TH-N120TAKP TH-N220RHKP TH-N120KP TH-N120TAHZKP TH-N220HZKP JIS, JEM, IEC, VDE, BS, UL, GB -10 to +40 (Stard: 20 C; maximum temperature on the board: 55 C) 0 (DC) to to 60 φ 1.6, 1.25 to (5 to 125) 125 ( to 150) Power consumption [VA/element] at minimum/maximum stabilization 3.0 / /.6 Terminal screw size M M Compatible with terminal Electric wire size [mm 2 ] Crimp lug size - to 3-3- to - Contact arrangement 1a1b 1a1b Conventional free air thermal current Ith [A] 5 5 Category AC-15 24VAC 2 / 3 2 / 3 AC operated Magnetic Contactors Coil opening closing 120VAC 2 / 3 2 / 3 a contact/b contact 240VAC 1 / 2 1 / 2 The value in brackets indicates the rating for automatic reset. 550VAC 0.5 / / 1 Category DC-13 24VDC 1 1 DC operated Magnetic Contactors Coil opening closing 110VDC The value in brackets indicates the rating for automatic reset. 220VDC Minimum applicable load level 20V 5mA 20V 5mA Terminal screw size M4 M4 Electric wire size [mm 2 ] Compatible with terminal Crimp lug size to 2-4, 5.5-S to 2-4, 5.5-S4 Operating characteristic curve description page Vibration resistance (vibration resistance malfunction performance) Page 6 10 to 55Hz 19.6m/s2 Trip-free Reset method Manual/Automatic switchable Manual/Automatic switchable Operation indication (lever indication) Manual trip check Frame of magnetic contactor that can be combined with the product N125, N150 N125, N150 N150 Delayed reaction model With 2 elements (TH-SR) (TH-N120SR) (TH-N120TASR) 2E format (TH-KPSR) (TH-N120KPSR) (TH-N120TAKPSR) Quick response model With 2 elements (TH-SR) 2E format (TH-KPSR) Charging part protection cover Reset release (UN-RR6) (UN-RR6) Operating status display (UN-TL60) (UN-TL60) Main unit / IEC35mm rail attachment unit Cover to prevent mistaken operation (UN-CV603) (UN-CV603) Rating Operational Current [A] φ 1.6, 1.25 to 2 2 (65 to ) 105 (5 to 125) 125 ( to 150) 150 (120 to 10) 10 (140 to 220) 1.0 / 2.3 (Note 5) N10, N220 N220 (TH-N220SR) (TH-N220KPSR) (UN-RR6) (UN-TL60) (UN-CV603) M to a1b 5 2 / 3 2 / 3 1 / / V 5mA M4 φ 1.6, 1.25 to to 2-4, 5.5-S4 Manual/Automatic switchable Notes 1: The ambient temperature compensator is mounted on all types. 2: The mark indicates a stard model (stard equipment), the indicates substard models, the indicates a special product, the indicates that this item cannot be manufactured. 3: In the case of a single unit attachment to the model with CAN terminal, the model name will be TH-N20CXHZ or TH-N20CXHZKP. 4: The TH-N600 (KP) model should be used in combination with a transformer made for measuring instruments (Rated secondary load of 15VA above). Recommended models for use with the 250, A are the CW-15LM or the CW-15L. In case of 660A is the CW-40LM. The current transformation ratio is listed in the heater designation column of the table. 5: The power consumption shown includes only the power consumed by the heating element. (The power consumed by the transformer in N220 - N600 frames is not included) 6: TH-N1DM (KP) meets the specification to use in combination with SD-Q19. The structure of the TH-N1 (KP) is different, but the other points (specifications, properties, functionality) are same. Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit

224 4 Magnetic Contactor Starters Thermal Overload Relays Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit TH-N series Option Applied product /Functions Operation circuit (contact) specifications Main circuit specifications Model name W H D Use condition Frame N400 N600 Appearance with 2-elements Applicable stard For Magnetic Starters For independent mounting with For Magnetic Starters 3-elements For independent mounting Outside dimensions [mm] For Magnetic Starters W H D For independent mounting Product weight For Magnetic Starters [kg] For independent mounting Ambient temperature [ C] Frequency [Hz] Heater designation (adjustable range of stabilized current) [A] (The dotted lines ( ) on the table to the right show the compatibility with the frames of magnetic contactors) (For heater designations of applied products, refer to the relevant portion of the main document) Power consumption [VA/element] at minimum/maximum stabilization Rating Operational Current [A] Terminal screw size Electric wire size [mm 2 ] Compatible with terminal Crimp lug size Contact arrangement Conventional free air thermal current Ith [A] Category AC-15 24VAC AC operated Magnetic Contactors 120VAC Coil opening closing a contact/b contact 240VAC The value in brackets indicates the rating for automatic reset. 550VAC Category DC-13 24VDC DC operated Magnetic Contactors Coil opening closing 110VDC The value in brackets indicates the rating for automatic reset. 220VDC Minimum applicable load level Terminal screw size Electric wire size [mm 2 ] Compatible with terminal Crimp lug size Operating characteristic curve description page Vibration resistance (vibration resistance malfunction performance) Trip-free Reset method Operation indication (lever indication) Manual trip check Frame of magnetic contactor that can be combined with the product With 2 elements (TH-SR) Delayed reaction model 2E format (TH-KPSR) With 2 elements (TH-SR) Quick response model 2E format (TH-KPSR) Charging part protection cover Reset release Operating status display Main unit / IEC35mm rail attachment unit Cover to prevent mistaken operation TH-N400RH (Note 4) TH-N600 TH-N400HZ TH-N400RHKP TH-N600KP (Note 4) TH-N400HZKP JIS, JEM, IEC, VDE, BS, UL, GB -10 to +40 (Stard: 20 C; maximum temperature on the board: 55 C) 50 to (5 to 125) 250 (200 to 300) 125 ( to 150) (Current transformation ratio: 400/5A) 150 (120 to 10) 330 (260 to 400) 10 (140 to 220) (Current transformation ratio: 500/5A) 250 (200 to 300) 500 (400 to 600) 330 (260 to 400) (Current transformation ratio: 750/5A) 660 (520 to 00) (Current transformation ratio: 0/5A) * The thermal relay parts of heater designations of 10A below are same with the N220 frame. N300, N400 N400 (TH-N400SR) (TH-N400KPSR) (UN-RR6) (UN-TL60) (UN-CV603) 1.0 / 2.3 (Note 5) M to a1b 5 2 / 3 2 / 3 1 / / V 5mA M4 φ 1.6, 1.25 to to 2-4, 5.5-S4 Manual/Automatic switchable Page 6 10 to 55Hz 19.6m/s2 (TH-N600SR) (TH-N600KPSR) (UN-RR6) (UN-TL60) (UN-CV603) 1.0 / 2.3 (Note 5) 1a1b 5 2 / 3 2 / 3 1 / / V 5mA M4 φ 1.6, 1.25 to to 2-4, 5.5-S4 Manual/Automatic switchable N600, N00 Notes 1: The ambient temperature compensator is mounted on all types. 2: The mark indicates a stard model (stard equipment), the indicates substard models, the indicates a special product, the indicates that this item cannot be manufactured. 3: In the case of a single unit attachment to the model with CAN terminal, the model name will be TH-N20CXHZ or TH-N20CXHZKP. 4: The TH-N600 (KP) model should be used in combination with a transformer made for measuring instruments (Rated secondary load of 15VA above). Recommended models for use with the 250, A are the CW-15LM or the CW-15L. In case of 660A is the CW-40LM. The current transformation ratio is listed in the heater designation column of the table. 5: The power consumption shown includes only the power consumed by the heating element. (The power consumed by the transformer in N220 - N600 frames is not included) 6: TH-N1DM (KP) meets the specification to use in combination with SD-Q19. The structure of the TH-N1 (KP) is different, but the other points (specifications, properties, functionality) are same.

225 Low-Voltage Circuit P.664 Magnetic Contactor Starters P.50 5 Thermal Overload Relays (Product Introductions) TH-T series Model name TH-T1 TH-T25 TH-T50 TH-T65 TH-T Application MSO-T10 -T12 -T20 MSOD-T12 -T20 MSO-T21 -T25 -T35 MSOD-T21 -T , 0.17, 0.24, 0.35, 0.5, 0.24, 0.35, 0.5, 0.7, 0.9, 29, 35, 42 15, 22, 29 67, 2 Stard heater rating (designation) 0.7, 0.9,1.3, 1.7, 2.1, 2.5, 1.3, 1.7, 2.1, 2.5, 3.6, 5, 35, 42, 54 (A) 3.6, 5, 6.6, 9, 11, , 9, 11, 15, 22 Contact arrangement 1a1b 1a1b 1a1b 1a1b 1a1b B C A A (Unit: mm) Heater types Heater types of TH type Thermal Overload Relays -T35 -T50 MSO-T35 -T50 MSOD-T35 -T50 MSO-T65 -T0 -T MSOD-T65 -T0 -T MSO-T0 B C T MSOD-T0 For Magnetic Starters For single mounting Model Heater designation (adjustable range of stabilized current) (A) 2-element 3-element (2E) 2-element 3-element (2E) T1 T1KP 0.12(0.1 to 0.16) 0.17(0.14 to 0.22) 0.24(0.2 to 0.32) 0.35(0.2 to 0.42) 0.5(0.4 to 0.6) 0.7(0.55 to 0.5) 0.9(0.7 to 1.1) (Note 1) (Note 1) 1.3(1 to 1.6) 1.7(1.4 to 2) 2.1(1.7 to 2.5) 2.5(2 to 3) 3.6(2. to 4.4) 5(4 to 6) 6.6(5.2 to ) 9(7 to 11) 11(9 to 13) 15(12 to 1) T25 T25KP T25 T25KP 0.24(0.2 to 0.32) 0.35(0.2 to 0.42) 0.5(0.4 to 0.6) 0.7(0.55 to 0.5) 0.9(0.7 to 1.1) 1.3(1 to 1.6) 1.7(1.4 to 2) 2.1(1.7 to 2.5) (Note 1) (Note 1) 2.5(2 to 3) 3.6(2. to 4.4) 5(4 to 6) 6.6(5.2 to ) 9(7 to 11) 11(9 to 13) 15(12 to 1) 22(1 to 26) T50 T50KP 29(24 to 34) 35(30 to 40) 42(34 to 50) T65 T65KP T65 T65KP 15(12 to 1) 22(1 to 26) 29(24 to 34) 35(30 to 40) 42(34 to 50) 54(43 to 65) T TKP 67(54 to 0) 2(65 to ) T1FSKP 2.1(1.7 to 2.5) 3.6(2. to 4.4) 5(4 to 6) 6.6(5.2 to ) 9(7 to 11) 11(9 to 13) 15(12 to 1) (Note 1) (Note 1) T25FS T25FSKP T25FS T25FSKP 2.1(1.7 to 2.5) 3.6(2. to 4.4) 5(4 to 6) 6.6(5.2 to ) 9(7 to 11) 11(9 to 13) 15(12 to 1) 22(1 to 26) T50FS T50FSKP 29(24 to 34) 35(30 to 40) 42(34 to 50) T65FS T65FSKP T65FS T65FSKP 42(34 to 50) 54(43 to 65) TFS TFSKP 67(54 to 0) 2(65 to 93) T1SR 0.24(0.2 to 0.32) 0.35(0.2 to 0.42) 0.5(0.4 to 0.6) 0.7(0.55 to 0.5) 0.9(0.7 to 1.1) 1.3(1 to 1.6) 1.7(1.4 to 2) 2.1(1.7 to 2.5) (Note 1) 2.5(2 to 3) 3.6(2. to 4.4) 5(4 to 6) 6.6(5.2 to ) 9(7 to 11) 11(9 to 13) 15(12 to 1) T25SR T25KPSR T25SR T25KPSR 0.24(0.2 to 0.32) 0.35(0.2 to 0.42) 0.5(0.4 to 0.6) 0.7(0.55 to 0.5) 0.9(0.7 to 1.1) 1.3(1 to 1.6) 1.7(1.4 to 2) 2.1(1.7 to 2.5) (Note 1) (Note 1) 2.5(2 to 3) 3.6(2. to 4.4) 5(4 to 6) 6.6(5.2 to ) 9(7 to 11) 11(9 to 13) 15(12 to 1) 22(1 to 26) T50SR T50KPSR 29(24 to 34) 35(30 to 40) 42(34 to 50) T65SR T65KPSR T65SR T65KPSR 15(12 to 1) 22(1 to 26) 29(24 to 34) 35(30 to 40) 42(34 to 50) 54(43 to 65) TSR TKPSR 67(54 to 0) 2(65 to ) Note 1: Combining UT-HZ1 allows the T1 frame to be used singly (screw mounting or IEC 35 mm rail mounting). Combining UN-RM20 allows the T25 frame for single mounting to have the IEC 35mm rail mounted. Stard Quick trip type Delay trip type TH-N series -T Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor TH-N120TA TH-N400HZKP Thermal Overload Relays Model name Application Stard heater rating (designation) (A) Contact arrangement (rated) TH-N120 TH-N120TA TH-N120TAHZ TH-N220RH TH-N220HZ TH-N400RH TH-N400HZ TH-N600 MSO-N125 -N150 Single attachment possible 42, 54 67, 2 MSO-N125 -N , 125 For single mounting MSO-N10 -N220 2, 105, , 10 For single mounting MSO-N300 -N400 1a1b (a contact 110VAC2A, 220VAC1A, b contact 110VAC 3A, 220VAC2A) 105, 125, , 250, 330 For single mounting This should be used in combination with a transformer for use with measuring instruments (15VA). 250 (transformer 400/5A) 330 (transformer 500/5A) 500 (transformer 750/5A) 660 (transformer 0/5A) Contactor Relays Option Unit Solid State Contactors B C A B C Product weight [kg] Stard item with 2 elements TH- A Motor Circuit Special Quick response model (with 2E) Saturated reactor attached Corrosion resistant model TH-FS TH-SR TH-YS Notes 1: For single attachment models, it is possible to attach only the thermal relays with wiring. 2: "CX" of the model name refers to the CAN terminal attachments.

226 6 Magnetic Contactor Starters Thermal Overload Relays Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Heater types Types of heaters in TH model thermal relays For Magnetic Starters For single mounting 2-element (2E)3-element 2-element (2E)3-element N120 N120TA N220RH N400RH N120KP N120TAKP N220RHKP N400RHKP N120 N120TAHZ N220HZ N400HZ N120KP N120TAHZKP N220HZKP N400HZKP Heater designation (adjustable range of stabilized current) (A) 42(34 to 50) 54(43 to 65) 67(54 to 0) 2(65 to ) 105(5 to 125) 125( to 150) 2(65 to ) 105(5 to 125) 125( to 150) 150(120 to 10) 10(140 to 220) 105(5 to 125) 125( to 150) 150(120 to 10) 10(140 to 220) 250(200 to 300) 330(260 to 400) N600 N600KP 250(200 to 300) 330(260 to 400) 500(400 to 600) 660(520 to 00) * When combined with a transformer (see notes) Notes 1: The TH-N600 (KP) model should be used in combination with a transformer for measuring instruments (Rated load of 15VA current transformation ratio as follows; 250A: 400/5A, 330A: 500/5A, 500A: 750/5A, 660A: 0/5A). 2: "CX" of the model name refers to the CAN terminal attachments. Comparison of operating properties of various motor protection relays Operating time (hr.) 2 (min.) (sec.) ET-N model open phase operation ET-N model overcurrent operation (600%) 30 seconds TH-SR model (saturated reactor attached) 15 seconds TH model (stard) 7 TH-KP model (2E attached) seconds TH-KP model open phase properties 3 seconds TH-KP model (2E quick response model) Motor Circuit Solid State Contactors Option Unit Contactor Relays ET-N model reverse phase operation Multiple of stabilized current TH model stard (2 elements attached) thermal relay General overloading/locking protection for the motor. TH-KP model thermal relay with 2E (can also be used with 3 elements) General overloading/locking/phase failure protection for the motor. Overloading/locking/phase failure protection for motors with a 3-phase 4-wire system of power distribution. TH-SR model thermal relay with saturated reactor Overloading/locking protection for motors with a long startup time or for motors that are frequently used for inching or intermittent operation. TH-KF model thermal relay with quick response properties (also used with 2E) Protection for motors with a short allowable time for locking such as underwater motors, etc. TH-FS model thermal relay with quick response properties 2 elements Locking protection for refrigerator compressor motors etc. ET-N model electronic motor protection relay Protection from overloading locking of motors, as well as a wide range of phase failure phase reversals, etc.

227 Low-Voltage Circuit P.664 Magnetic Contactor Starters P.50 7 Contactor Relays Specification SR-T series Number of poles Contact arrangement Model name Rated insulation voltage [V] Applicable stard Rated impulse withst voltage [kv] Rated frequency [Hz] Pollution degree 120VAC Category AC-15 (Coil load) 240VAC 440VAC 550VAC 120VAC Category AC-12 (resistive load) 240VAC 440VAC 550VAC 24VDC Category DC-13 (large coil load) 4VDC 110VDC 220VDC 24VDC Category DC-12 (resistive loads) 4VDC 110VDC 220VDC Minimum applicable load level Mechanical durability [ten thous times] Electrical durability [ten thous times] Switching frequency [time/hour] Coil consumption (Note 3) Inrush [VA] Sealed [VA] Power consumption (Note 3) [W] Contact rating (Note 1) Performance Characteristic AC rated operational current [A] DC rated operational current [A] SR-T5 SR-T a 9a 4a1b 7a2b 3a2b 5a4b 690 IEC , EN , JIS C / (2) 0.3(0.) 10 5() 1(3) 20V 3mA 1, , Features/ Summary List Produced Models Selections Order Procedure Optional unit (Note 2) Surge absorber unit Additional auxiliary contact block Magnetic Starter/ Contactor IEC 35mm rail mounting Notes 1: The value in brackets indicates the current when switching the load with two poles installed in series. 2: In the optional unit field, indicate mountable non-mountable, respectively. 3: Coil consumption are average values in case of applying 220V60Hz to AC200V coil. Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit

228 Magnetic Contactor Starters Contactor Relay Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit SR-K series Contact rating (Note 2) Frame Appearance Number of poles Contact arrangement K 10 10a, 9a1b a2b, 7a3b 6a4b, 5a5b Conventional free air thermal current Ith [A] VAC 6 Category AC VAC 5 (Coil load) 440VAC 3 550VAC 3 110VAC 16 Category AC VAC 12 (resistive load) 440VAC 5 550VAC 5 24VDC 5 Category DC-13 4VDC 3 (large coil load) 110VDC 0.(2) 220VDC 0.2(0.) 24VDC 10 Category DC-12 4VDC (resistive loads) 110VDC 5() 220VDC 1(3) Stard SR- DC operated type SRD- SRL- Mechanically latched type SRLD- With large rated SR-JH auxiliary contacts SRD-JH SR-LC With overlapping contacts SRD-LC SR-CX With terminal cover SRD-CX With surge absorber (Note 3) (Note 4) DC/AC interface Charging part protection cover (Note 4) IEC 35mm rail mounting type 690V applicable Notes 1: mark is stard, mark is substard, is not able to be manufactured. 2: Where large capacity or overlapping contacts are included, the rating of the contacts can be found by referring to the individual ratings table. Values in brackets ( ) are for two pole straight line load switching. 3: In the case of mechanical latch (SRL-K, SRLD-K) models, one absorber can be attached to each of closing tripping coils. 4: Surge absorption units DC/AC interface units cannot be attached together as additions to the coil terminal of an contactor relay at the same time. 5: The mark in the option unit column indicates that this option can be manufactured; the indicates that it cannot be manufactured. Motor Circuit Solid State Contactors Optional unit AC rated operational current [A] DC rated operational current [A] SR-K

229 Low-Voltage Circuit P.664 Magnetic Contactor Starters P.50 9 Optional Units Model List MS-T series Model name Auxiliary contact blocks Operation coil surge absorber unit Mechanical interlocks Type Mounting Specification/ Function Appearance (Typical example) UT-AX4 Twin contact built-in auxiliary contact (4a, 2a2b, 3a1b) Front clip-on UT-AX2 Twin contact built-in 2-pole auxiliary contact (2a, 1a1b, 2b) UT-AX11 UT-SA23 UT-SA21 UT-SA22 UT-SA25 UT-ML11 Side clip-on Twin contact built-in 2-pole auxiliary contact (1a1b) With CR 200VAC Mounting on top Operation coil surge absorber With varistor 4VAC (Shared with DC) 200VAC (Shared with DC) 400VAC With varistor + indicating LED 200VAC (Shared with DC) With varistor + CR 4VAC (Shared with DC) 200VAC (Shared with DC) Side clip-on Combining it with two single Magnetic Contactors configures the reversing type. ML11 is the electrical interlock 2b contact built-in type. Applied model Others Magnetic Starters Magnetic Contactors Contactor Relays UT-AX4 UT-AX2 UT-AX11 UT-SA21 UT-ML11 T10-T32 T10-T32 T10-T32 T10-T20 SR-T5 SR-T5 SR-T5/T9 Combination with Combination with UT-AX11 is not available. UT-AX2/4 is not available. Features/ Summary List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors Motor Circuit

230 90 Magnetic Contactor Starters Optional Units MS-T/N series Model name Auxiliary contact blocks Auxiliary contact unit for low level signals Type UT-AX2(BC) UT-AX4(BC) UT-AX11(BC) UN-AX2(CX) UN-AX4(CX) UN-AX11(CX) UN-AX0 UN-AX150 UN-AX600 UN-LL22(CX) Mounting Front clip-on Side clip-on Front clip-on Side clip-on Front clip-on Specification/ Function Twin contact built-in 2-pole auxiliary contact (2a, 1a1b, 2b) Twin contact built-in auxiliary contact (4a, 2a2b, 3a1b) Twin contact built-in 2-pole auxiliary contact (1a1b) Twin contact built-in 2-pole auxiliary contact (2a, 1a1b, 2b) Twin contact built-in auxiliary contact (4a, 2a2b, 3a1b) Twin contact built-in 2-pole auxiliary contact (1a1b) Twin contact built-in 2-pole auxiliary contact (1a1b) Twin contact built-in 2-pole auxiliary contact (1a1b) Twin contact built-in auxiliary contact (2a2b) A combination of 2 low level signal contacts twin (stard) contacts, for a total 4 pole auxiliary contact structure For low level signals 1a1b (5V 5mA) Twin contact 1a1b (20V 5mA) Features/ Summary Appearance List Produced Models Selections Order Procedure (Typical example) UT-AX2 UT-AX4 UT-AX11 UN-AX2 UN-AX4 UN-AX11 UN-AX0 UN-AX150 UN-AX600 UN-LL22 Stard compliance achieved UL CSA UL CSA UL CSA UL CSA UL CSA UL CSA UL CSA UL CSA UL CSA UL CSA Product weight [g] Others Combination with UT-AX11(BC) is not available. Combination with UT-AX2, 4(BC) is not available. Combination with UN-AX11(CX) is not available. Combination with UN-AX2, 4, LL22(CX) is not available. Combination with UN-AX11(CX) is not available. Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Model name DC/AC interface unit for operating coils Type UT-SY21(BC) UT-SY22(BC) UN-SY11 UN-SY12 UN-SY21(CX) UN-SY22(CX) UN-SY31 UN-SY32 UN-CV0 Mounting Specification/ Function Mounting on top For Independent mounting Mounting on top The magnetic contactor contactor relay operating on alternating current can be controlled with 24VDC. TRIAC output Input 24VDC 15mA Relay output Input 24VDC 10mA TRIAC output Input 24VDC 15mA Relay output Input 24VDC 10mA TRIAC output Input 24VDC 15mA Relay output Input 24VDC 10mA TRIAC output Input 24VDC 15mA Relay output Input 24VDC 10mA For magnetic contactor For contactor relays UN-CV251, CV2 For magnetic starters (MSO- ) Protective cover units UN-CZ605 UN-CZ0 UN-CZ2 UN-CZ1 UN-CZ4 Front clip-on Charging part protection cover Thermal relay for (TH-T65, TH-N60) For magnetic contactors (power source side load side) For magnetic starters (power source side) For reversing magnetic contactors For magnetic starters (load side) For reversing magnetic starters UT-CV, UN-CV Mistaken operation prevention cover UN-CV117 For use with magnetic contactors contactor relays UN- CV3 For thermal relay (TH- ) UN-CV30 For pneumatic timers UT-CW, UN-CW terminal cover For magnetic contactor For contactor relays For thermal relay Option Unit Appearance Solid State Contactors Motor Circuit (Typical example) UT-SY21 UN-SY11 UN-SY21 UN-SY32 UN-CV250 UN-CZ605 UN-CZ500 UN-CZ501 UN-CV103 UT-CW110 Stard compliance achieved Product weight [g] Others Notes 1: There are limits on types, rated voltage use in combination with other models. 2: There is also the UN-RY10 (applicable models: 2XN10 & N11), which integrates the 3 connecting conductors each on the power source load sides. 3: There is also the UN-RY10L (applicable models: 2XN10 & N11), which integrates 3 connecting conductors.

231 Low-Voltage Circuit P.664 Magnetic Contactor Starters P Operation coil surge absorber unit Main circuit surge absorption unit UT-SA3 UT-SA21 UT-SA22 UT-SA25 UN-SA3 UN-SA21 UN-SA22 UN-SA25 UN-SA721 UN-SA712 UN-SA722 UN-SA713 UN-SA723 UN-SA725 UT-SA33 UN-SA33 With CR With varistor UT-SA23 200VAC UT-SA13 200VDC 4VAC (Shared with DC) 200VAC (Shared with DC) 400VAC With varistor With varistor With CR With varistor + indicating + With CR LED 200VAC (Shared with DC) 4VAC (Shared with DC) 200VAC (Shared with DC) UN-SA13 200VDC UN-SA23 200VAC 200VAC (Shared with DC) 400VAC Mounting on top Operation coil surge absorber With varistor With varistor + indicating + With CR LED 200VAC (Shared with DC) 4VAC (Shared with DC) 200VAC (Shared with DC) With varistor With varistor + indicating LED 4VAC VAC (Shared with DC) (Shared with DC) 200VAC (Shared with DC) VAC (Shared with DC) 200VAC (Shared with DC) 400VAC With CR With CR With varistor + With CR 200VDC 200VAC 4VAC (Shared with DC) VAC (Shared with DC) 200VAC (Shared with DC Front clip-on Independent mounting Main circuit surge absorber With CR 240VAC (AC to 240V) Features/ Summary UT-SA21 UT-SA22 UN-SA21 UN-SA22 UN-SA721 UN-SA712 UN-SA722 UN-SA713 UN-SA723 UN-SA725 UT-SA33 UN-SA33 UL CSA UL CSA UL CSA UL CSA UL CSA UL CSA UL CSA Mechanical interlock unit UT-ML11 (BC) Combined with two single units of magnetic contactors to form a reversing model. The model incorporates an electric interlock 2b contact UT-ML20 (BC) Side clip-on Combined with two single units of magnetic contactors to form a reversing model. The model incorporates an electric interlock 2b contact Main circuit conductor kit 3 pole parallel connection unit UN-ML UT-SD UN-SD UT-SG UN-SG UN-YG UT-YD20 UN-YD UT-YY20, UN-YY Combined with two single units of magnetic contactors to form a reversing model. The ML11(CX) incorporates an electric interlock 2b contact Connecting conductor for reversing model magnetic contactors Connecting conductor for jumper connecting reversing model magnetic contactors Main cuit 3 pole connecting conductor for short circuits 3 pole 2 pole connecting parallel conductor for short connecting circuits conductor Connecting conductor kit UT-TH50, UN-TH Conductor for connecting magnetic contactors thermal relays Fault detection unit UN-FD (CX) Independent mounting Detecting the conduction mode (contact welds) of the main circuit VAC 200VAC Reset release LED display UT-RR UN-RR UN-TL UT-HZ1 (BC) Single attachment unit Front clip-on Front clip-on For use in thermal resets outside the circuit board 200mm 400mm 550mm 0mm Thermal relay trip display VAC 200VAC 24VDC UN-RM20 Can be Can be attached attached with TH-T25 with TH-T1, TH-20, using screws using screws or with the or with the IEC35mm IEC35mm rails. rails. List Produced Models Selections Order Procedure Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit UT-ML11 UT-ML20 UN-ML21 UN-FD4 UT-HZ1 UN-RM20 UL CSA UL CSA UL CSA Solid State Contactors Motor Circuit

232 92 Magnetic Contactor Starters Solid State Contactors Solid State Contactors Model List US-Nh/Kh Model Solid State Contactors (Stard Models) 200VAC series AC-1 rated operating current [A] Heater capacity [kw] 3φ200V Maximum applicable motor capacity [kw] 3φ200V (Note 3) For 3 phase load US-N US-K 1φ 200V (Note 2) US-N5SS US-N5SSTE US-NSS US-NSSTE US-N20 US-N20TE US-N30 US-N30TE (Note 4) US-N40 US-N40TE US-N50 US-N50TE (Note 4) (Note 1) 11 (Note 1) US-NNS US-NNSTE US-N0NS US-N0NSTE Features/ Summary For single phase load For combined 3 phase load US-K US-K List Produced Models Selections Order Procedure AC-1 rated operating current [A] Heater capacity [kw] 1φ400V (Note 2) 3φ400V Maximum applicable motor capacity [kw] 3φ400V (Note 3) (Note 1) 22 (Note 1) Magnetic Starter/ Contactor 400VAC series For 3 phase load US-N US-NH US-KH US-N20 US-N20TE US-N30 US-N30TE (Note 4) US-N40 US-N40TE US-N50 US-N50TE (Note 4) US-NHNS US-NHNSTE US-NH0NS US-NH0NSTE Thermal Overload Relays For single phase load For combined 3 phase load US-KH Contactor Relays US-KH Option Unit Solid State Contactors IEC 35mm rail mounting type Can be manufactured with stard products Charging part protection cover unit Driving unit Driving unit with output UA-SH (Note ) Reversing unit Fault Detection Unit Power control unit (Note 6) Equipped with stard products (Except US-K, KH) UA-DR1 UA-SH1 UA-RE UN-FD (for 200V main circuit) & UN-FD4 (for 400V main circuit) UA-PC Motor Circuit Option (Note 5) UA-SH UA-DR1 UA-SH1 UA-RE

233 Low-Voltage Circuit P.664 Magnetic Contactor Starters P (Note 1) 15 (Note 1) (Note 1) 1.5 (Note 1) US-KTE US-K120TE US-K150TE (Note 1) 22 (Note 1) US-KD Model Solid State Contactor (For Direct Current Load) Direct Current DC-1 rated operating current [A] Rated voltage For direct current load US-KD IEC 35mm rail mounting type Driving unit Option with output DC24 to 110V US-KD Can be manufactured with stard products UA-SH US-K US-K150 US-K US-Hh Model Solid State Contactor AC-1 rated operating current [A] (-10 to 40 C) Heater capacity 1φ200V 4 6 [kw] (-10 to 40 C) 3φ200V (Note ) 3φ400V Features/ Summary List Produced Models (Note 1) 30 (Note 1) (Note 1) 37 (Note 1) (Note 1) 45 (Note 1) US-H Selections Order Procedure US-KHTE US-KH120TE US-KH150TE US-KH US-KH150 US-KH200 US-H20 US-H20DD US-H30 US-H30DD US-H40 US-H40DD US-H50 US-H50DD IEC 35mm rail mounting type (Note 6) Fault Detection Unit UN-FD (for 200V main circuit) & UN-FD4 (for 400V main circuit) Option Power control unit UA-PC Charging part protection cover unit UN-CV501US Notes 1: When used with the US-K(H)h model, this shows the capacity when applied to a 3 phase load by combining two or three units of the US-K(H)h model for single phase load together. 2: Shows the capacity for each pole. 3: Motor load application capacity will vary depending on the conditions of use. 4: The photograph shows the US-NhTE model. The external dimensions of the US-Nh model are smaller. 5: The option unit column shows the extent of application. 6: Can be attached with the specialized product (US-hRM). 7: This shows the values when the main circuit control format is controlled collectively. : When the US-N5SS/NSS (TE) model is attached to the UA-SH driving unit with output, remove the cover of the US-Nh model main unit. Magnetic Starter/ Contactor Thermal Overload Relays Contactor Relays Option Unit Solid State Contactors UN-FD UA-PC Motor Circuit

234 94 Magnetic Contactor Starters Motor Features/ Summary Motor MMP-T series Features Protects failure of the industrial motor by means of a single device One Motor Circuit can detect overload operation phase-loss operation of a motor also makes it possible to cut off short-circuit current. This compact body Motor Circuit achieves a rated short-circuit breaking capacity of ka (200/240V). Improves safety during product maintenance The Motor Circuit is provided with a DIN VDE stards-compliant charging part protection cover as stard. This cover helps to improve safety during maintenance work. Reduces the size of the control board distribution board The internal structure of the Motor Circuit has been optimized to reduce depth. When a connection conductor unit (UT-MT) is used, it will further reduce the size of the control board distribution board. Furthermore, it can be assembled with an auxiliary contact/alarm contact unit as well as a short-circuit indicator unit (displays in red when short-circuit occurs) in a 45mm-width body. Example of wiring with connection conductor unit List Produced Models conductor unit Magnetic Contactor coil terminal section Selections Order Procedure MMP-T32 Magnetic Starter/ Contactor Model Code MMP-T series MMP T32 BC 32A Thermal Overload Relays Model name Model Frame Specification Code Specification Heater designation (A) Current setting range (A) MMP AC operated type T32 32A BC With fast wiring terminal Contactor Relays Option Unit Solid State Contactors Motor Circuit

Molded Case Circuit Breakers Earth Leakage Circuit Breakers. Mitsubishi Molded Case Circuit Breakers and Earth Leakage Circuit Breakers

Molded Case Circuit Breakers Earth Leakage Circuit Breakers. Mitsubishi Molded Case Circuit Breakers and Earth Leakage Circuit Breakers Molded Case Circuit s Earth Leakage Circuit s Mitsubishi Molded Case Circuit s and Earth Leakage Circuit s 1 INDEX 1 3 6 9 Introduction and Features of WS-V Series 1. Outline of Mitsubishi Circuit s 1)

More information

World Super Series WSS The extensive breaker series from Mitsubishi Electric

World Super Series WSS The extensive breaker series from Mitsubishi Electric MODEL PUSH TO TRIP TEST 3 P IEC60947-2 JIS C 8201-2 Ue 690VAC 00VAC 440VAC 41VAC 400VAC 380VAC 230VAC T Ir Ip Is Ts EN60947-2 40 C Icu/Ics 8/8kA 30/30kA 8/8kA MODEL POLE Ui 690VAC 0-60Hz 8kV Uimp PUSH

More information

Mitsubishi Breaker Line-up

Mitsubishi Breaker Line-up Mitsubishi Breaker Line-up MCB DIN Series MCCB WS-V Series MCCB WS Series ACB AE-SW Series CP DIN Series December 4 th, 2015 Mitsubishi Electric Corp. Fukuyama Works Page 1 Agenda 1 2 3 LVS Product Overview

More information

Series MOLDED-CASE CIRCUIT BREAKERS & EARTH-LEAKAGE CIRCUIT BREAKERS 07 A EC97J1128

Series MOLDED-CASE CIRCUIT BREAKERS & EARTH-LEAKAGE CIRCUIT BREAKERS 07 A EC97J1128 MOLDED-CASE CIRCUIT BREAKERS & EARTH-LEAKAGE CIRCUIT BREAKERS W o r l d S u p e r Series EC97J11 Mitsubishi Electric Corporation's Fukuyama Works, which produces these products, is certified as meeting

More information

LOW VOLTAGE SWITCHGEAR

LOW VOLTAGE SWITCHGEAR LOW VOLTAGE SWITCHGEAR S-N Motor Control Mitsubishi Electric s S-N Series contactors are perfect for the control of 3 phase power, either for the direct control of a motor, to supply power to a drive or

More information

MITSUBISHI ELECTRIC. Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors. WSS, PSS & Super Series 3 A 1600 A. Technical Catalogue

MITSUBISHI ELECTRIC. Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors. WSS, PSS & Super Series 3 A 1600 A. Technical Catalogue Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors WSS, PSS & Super Series A 100 A Technical Catalogue 2004 Circuit Breakers Circuit Breakers The new World Super Series WSS completes the

More information

MITSUBISHI NO-FUSE BREAKER NF125-SGW MODEL. In A Ir A 3P Uimp 8kV. 40 C Ue. Icu/Ics 690VAC. 8/8kA 525VAC. POLE Ui690V Cat.A.

MITSUBISHI NO-FUSE BREAKER NF125-SGW MODEL. In A Ir A 3P Uimp 8kV. 40 C Ue. Icu/Ics 690VAC. 8/8kA 525VAC. POLE Ui690V Cat.A. 0 0 0.5 T. 4 0 Ir 10 14 0 0.5 T Ir. 4 10 14 0 0 0.5 T. 4 0 Ir 10 14 0 0.5 T Ir. 4 10 14 ELECTRIC FACTORY AUTOMATI World Super Series POLE Ui90V Cat.A NF5-SGW 100 In A Ir -100A P Uimp kv PUSH TO TRIP 50/0Hz

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Interruption Technology of Breakers for High-voltage Direct Current

Interruption Technology of Breakers for High-voltage Direct Current Interruption Technology of Breakers for High-voltage Direct MORIAI Hiroshi ABSTRT Applications for direct current () electric distribution have been spreading along with the increase of data centers and

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

MOULDED CASE CIRCUIT BREAKERS, EARTH LEAKAGE CIRCUIT BREAKERS, EARTH LEAKAGE RELAYS & CIRCUIT PROTECTORS HANDLING AND MAINTENANCE 06A

MOULDED CASE CIRCUIT BREAKERS, EARTH LEAKAGE CIRCUIT BREAKERS, EARTH LEAKAGE RELAYS & CIRCUIT PROTECTORS HANDLING AND MAINTENANCE 06A MOULDED CASE CIRCUIT BREAKERS, EARTH LEAKAGE CIRCUIT BREAKERS, EARTH LEAKAGE RELAYS & CIRCUIT PROTECTORS HANDLING AND MAINTENANCE 06A CTENTS 1. Items to be practiced without fail for safety 1.1 Cautionary

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker & The Ultimate Safety Breaker Molded Case Circuit Breaker www.terasaki.co.jp Catalogue No. 13!5E ! Safety Notice Carefully read instruction manual to ensure proper installation, connection, operation,

More information

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker BREAKER Molded Case Circuit Breaker/Earth Leakage Circuit Breaker 2 BREAKER With an improved technology and agressive invesment in R&D, DAERYUK create differentiated value for each customer in order to

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker Molded Case Circuit Breaker + + + Building + + + a better + + future + + + + We, Hyundai Heavy Industries Co., Ltd., are challenging + + + + for better + future with + continuous + investment + in R&D

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

MOLDED CASE CIRCUIT BREAKERS

MOLDED CASE CIRCUIT BREAKERS MOLDED CASE CIRCUIT BREAKERS S series E series Handle-operated type Distribution breakers F series H series Solid-state trip type -pole S and E series INDIVIDUAL CATALOG from D&C CATALOG 9th Edition 0

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Low voltage circuit breakers

Low voltage circuit breakers Super Solution North American Edition Low voltage circuit breakers Contents Overview Main characteristics Accessories Technical information Mounting & connection Characteristics curves Dimensions A-1 A-2

More information

General data 5/37. Overview

General data 5/37. Overview General data Overview Benefits High short-circuit breaking capacity in the feeder Optimum usability in motor feeders for the special voltages 440 V, 480 V, 0 V and 690 V Compact design The are available

More information

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series Data Sheet Manual Motor Starter Ex9S32 Series na.noark-electric.com NOARK Ex9S32 Series Features Ex9S32 Manual Motor Starter provides manual isolation, manual motor control, and overcurrent protection

More information

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series Data Sheet Manual Motor Starter Ex9S32 Series na.noark-electric.com NOARK Ex9S32 Series Features Ex9S32 Manual Motor Starter provides manual isolation, manual motor control, and overcurrent protection

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Industrial Protection Products Edition

Industrial Protection Products Edition Industrial Protection Products 2016 Edition COMPANY PROFILE Shanghai Liangxin Electrical Co., LTD. one of the leading low-voltage electrical component manufacture in the high-end market, was established

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

B Mini Contactor V Hz

B Mini Contactor V Hz ABB B7-30-10-80 Mini Contactor 220-240V 40-450Hz General Information Extended Product Type Product ID B7-30-10-80 GJL1311001R8100 EAN 4013614150197 Catalog Description Long Description B7-30-10-80 Mini

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Molded Case Circuit Breakers Cerus TD and TS Series UL 489 Listed TD125U ln 15~125A 3.54(W) x 6.46(H) X 3.39in (D) TS250U ln150 ~ 250A 4.13 (W) x 7.01 (H) X 3.39in (D) TS400U ln 300 ~ 400A 5.51 (W) x 11.50

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays US Catalog January 2017 Motor protection and control Manual motor starters, contactors and overload relays Motor rated operational powers and currents The currents given below concern standard three-phase

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB)

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB) CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker 02 Part II Molded Case Circuit Breaker(MCCB) 07 UEM5 series Molded Case Circuit Breakers 08 UEM5L series

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

JDA. JD Auspice Co., Ltd. Catalogue

JDA. JD Auspice Co., Ltd. Catalogue Catalogue Switch-Disconnectors TD series Frame size [AF] Conventional thermal current, Ith [A] No. of poles Rated operational voltage, AC [V] Ue Rated operational current, Ie DC [V] Rated impulse withstand

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

3VT Kompaktleistungsschalter bis 630A

3VT Kompaktleistungsschalter bis 630A Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System pro M compact

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (00) 6-0 www.cmafh.com Safety Interlock Switches DSL-N Super Small Class 6-Contact uard Lock Safety-Door Switch

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

CirCuit Breakers and isolators Catalogue of installation and moulded Case devices

CirCuit Breakers and isolators Catalogue of installation and moulded Case devices www.noark-electric.eu CirCuit Breakers and isolators Catalogue of installation and moulded Case devices valid from 1 st september 2011 ew opportunity for you Contents OARK Electric Introduction... General

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - BNQ BNQD5T BNQD5 with Front Mounting Clips na.noark-electric.com NOARK Ex9 Series - BNQ Features The BNQ is compliant with UL/CSA/IEC standards

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

BC Mini Contactor VDC

BC Mini Contactor VDC ABB Mini Contactor 110-125VDC General Information Extended Product Type Product ID GJL1213001R0014 EAN 4013614052859 Catalog Description Long Description Mini Contactor 110-125VDC The BC6-30-01 mini contactor

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch Features () All models fully comply with IEC regulations () Units can be mounted on a standard 5mm IEC rail () Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable

More information

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers VCP-T/T-VAC medium voltage vacuum circuit breakers Control protect with Eaton s compact medium voltage circuit breakers Eaton Corporation has dedicated years of research, design testing to create a comprehensive

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information