Catalogue No. 10!64E.

Size: px
Start display at page:

Download "Catalogue No. 10!64E."

Transcription

1 Catalogue No. 10!6E

2

3 TBLE OF CONTENTS 1. Ratings and Specifications 1-1 Molded Case Circuit Breakers zfixed thermal and fixed magnetic MCCBs 1-2 cswitch-disconnectors 1- xdjustable thermal and adjustable magnetic MCCBs Mounting and Connection ztype of connections and mountings 2-2 List of connecting type 2-2 Connecting parts 2-3 xcompression terminals 2- cterminal screw sizes and standard torques 2-6 vinsulation distance from the line side 2-7 breverse connection 2-8 nlists of breaker mounting screws ccessories 3-1 zinternally mounted accessories 3-2 xexternally mounted accessories Connection diagrams and terminal numbers Motor operators (MC) Possible combinations Toggle holder (HH) and toggle lock () Ratings and operation data of auxiliary and 3. External operating handles 3-10 alarm switches3-3 (1) Breaker-mounted (HB) for E Shunt trip device (SHT) 3-3 (2) Breaker-mounted (field installable)(hb) 5. Undervoltage trip device (UVT) 3- for S160, E0, S (3) Door-mounted (depth adjustable) (HS) standard type 3-16 () Door-mounted (depth adjustable) (HP) ordinal type Interpole barriers (B) 3-5. Terminal covers CF/CR/CS3-26 (1) CF for front-connected breakers 3-26 (2) CR for rear-connected and plug-in breakers CS for front-connected breakers with cable clamps Terminal blocks (TF) Mechanical interlock3-30 Slide interlock (MS) Door Flange (DF) Characteristics and Outline Dimensions -1 E-SF-2 E160-SF- S160-SCF, S160-SF -6 E0-SF, S0-SF -8 S160-SCJ, S160-SJ -10 E0-SJ, S0-SJ -12 S160-SN -1 S0-SN -16

4 FETURES Saving space and saving money! No. Operation in pollution degree 3 to IEC standard No.1 Compact size: W75 H130 D68; and high breaking capacity: 0k 15V (S160-SF/SJ) No.6 IP20 protection for the terminals and IP30 protection for the front cover with toggle (with terminal covers) No.9 Two alarm switches can be easily installed No.7 Unique accessory cover opens with only one screw No.8 Practical internal accessories can be installed with one touch ayxiliary switch alarm switch shunt trip undervoltage trip No.10 Secure accessory cover retains nameplate No.3 Unlimited performance when reverse-connected No.5 Suitable for isolation with positive contact indication No.2 Huge adjustment range for overload protection: 63 to % Dial cover can be sealed. (djustable thermal MCCBs) VRIED TERMINTIONS cable clamp straight extension bar spread extension bar cable clamp for aluminum conductors front connections

5 Ratings and Specifications 1Molded Case Circuit Breakers zfixed thermal and fixed magnetic MCCBs 1-2 xdjustable thermal and adjustable magnetic MCCBs 1-3 cswitch-disconnectors 1-1 Ratings and Specifications 1-1

6 1Ratings and Specifications Molded Case Circuit Breakers zfixed thermal and fixed magnetic MCCBs Frame size () Type Number of poles Ratings Rated current, Calibrated at 0 C E-SF E160-SF (5 C only) 160 S160-SCF S160-SF E0-SF S0-SF center pole omitted Rated insulation voltageu i V C Rated impulse withstand voltage U imp kv Utilization Category Rated breaking capacity, k IEC C 690V I cu /I cs (sym) 500V 0V 15V 380V 20V DC 0V 1V Rated short time withstand current, k External dimensions, mm Weight (' marked standard type) kg Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread extension bars Cable clamps Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug5B (PG) DIN rail mount Clip-in chassis mount ccessories (optional) Symbol uxiliary switch larm switch Internally mounted Shunt trips Undervoltage trips Motor operator External operating Breaker-mounted a b c d handle Door-mounted (variable depth) Toggle extension Mechanical interlock Slide type Toggle holder Toggle lock Terminal cover For front-connected For rear-connected and plug-in For cable clamps Interpole barrier Terminal block for lead Door flange Standard specifications Overcurrent trip mechanism Trip button (color) Handle position indication (ON: Red, OFF: Green) Suitability for isolation CE marking Externally mounted a b d c /3.8 10/5 10/5 16/8 /13 7.5/3.8 15/ ' Thermal-magnetic7 (Red) Non Non /13 10/ ' Thermal-magnetic (Red) / 15/7.5 /13 /13 35/18 20/10 30/ ' Thermal-magnetic (Red) /3 10/7.5 /13 0/20 0/20 50/ /13 0/ ' Thermal-magnetic (Red) /7.5 15/12 /19 /19 35/27 15/12 / ' Thermal-magnetic (Red) /2 /13 30/15 0/20 0/20 85/3 /13 0/ ' Thermal-magnetic (Red) Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : yes or available. : no or not available. : DC rating available on request. : Line side interpole barriers are supplied as standard. (Front connection only) 7 : Hydraulic-magnetic type for below 10 rating. : Provided with DIN rail adaptor. 1-2

7 Ratings and Specifications Molded Case Circuit Breakers 1xdjustable thermal and adjustable magnetic MCCBs Frame size () Type Number of poles Ratings Rated current, Calibrated at 5 C Rated insulation voltageu i V C Rated impulse withstand voltage U imp kv Utilization Category Rated breaking capacity, k IEC C 690V I cu /I cs (sym) 500V 0V 15V 380V 20V DC 0V 1V Rated short time withstand current, k External dimensions, mm Weight (' marked standard type) kg Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread extension bars Cable clamps Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug5B (PG) DIN rail mount Clip-in chassis mount ccessories (optional) Symbol uxiliary switch larm switch Internally mounted Shunt trips Undervoltage trips Motor operator External operating Breaker-mounted a b c d handle Door-mounted (variable depth) Toggle extension Mechanical interlock Slide type Toggle holder Toggle lock Terminal cover For front-connected For rear-connected and plug-in For cable clamps Interpole barrier Terminal block for lead Door flange Standard specifications Overcurrent trip mechanism Trip button (color) Handle position indication (ON: Red, OFF: Green) Suitability for isolation CE marking Externally mounted a b d c 160 S160-SCJ / 15/7.5 /13 /13 35/18 20/10 30/ ' Thermal-magnetic (Red) 160 S160-SJ /3 10/7.5 /13 0/20 0/20 50/ /13 0/ ' Thermal-magnetic (Red) 0 E0-SJ /6 15/12 /19 /19 35/27 15/12 / ' Thermal-magnetic (Red) 0 S0-SJ /2 10/7.5 30/15 0/20 0/20 85/3 /13 0/ ' Thermal-magnetic (Red) Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : yes or available. : no or not available. : DC rating available on request. : Line side interpole barriers are supplied as standard. (Front connection only) : Provided with DIN rail adaptor. 1 Ratings and Specifications 1-3

8 1Ratings and Specifications Molded Case Circuit Breakers cswitch-disconnectors Frame size () Type Number of poles Ratings Rated current, Rated insulation voltageu i V Rated operational voltage V C C DC Rated short circuit making capacity, k peak Rated short time withstand current, k Rated impulse withstand voltage U imp kv Performance Utilization category C 690V IEC DC 0V Upstream breaker External dimensions, mm Weight (' marked standard type) kg Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread extension bars Cable clamps Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug5B (PG) DIN rail mount Clip-in chassis mount ccessories (optional) Symbol uxiliary switch larm switch Internally mounted Shunt trips Undervoltage trips Motor operator External operating Breaker-mounted a b c d handle Door-mounted (variable depth) Toggle extension Mechanical interlock Slide type Toggle holder Toggle lock Terminal cover For front-connected For rear-connected and plug-in For cable clamps Interpole barrier Terminal block for lead Door flange Standard specifications Trip button (color) Handle position indication (ON: Red, OFF: Green) Suitability for isolation CE marking Externally mounted a b d c 160 S160-SN sec 8 C-23 DC-22 S160-SF ' e (Red) 0 S0-SN sec 8 C-23 DC-22 S0-SF ' e (Red) Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : yes or available. : no or not available. : Line side interpole barriers are supplied as standard. (Front connection only) : Provided with DIN rail : Required for overcurrent protection. Rated conditional short-circuit current [I cc ] will be the same as Rated short-circuit breaking capacity of upstream breaker. 1-

9 Mounting and Connection 2 2zType of connections and mountings 2-2 List of connecting type2-2 Connecting parts2-3 xcompression terminals 2- cterminal screw sizes and standard torques 2-6 vinsulation distance from the line side 2-7 breverse connection 2-8 nlists of breaker mounting screws 2-8 Mounting and Connection 2-1

10 Mounting and Connection 2Molded Case Circuit Breakers ztype of connections and mountings List of connecting types Connecting types (bbreviation) For compression terminals / flat bars Front-connected (FC) With extension bars With cable clamps Rear-connected (RC) Flat bar studs Bolt studs Stud can be turned 5 or 90 Outer view Breaker E-SF ' E160-SF ' S160-SCF S160-SF S160-SCJ S160-SJ S160-SN E0-SF S0-SF E0-SJ S0-SJ S0-SN ' ' ' Connect compression terminals or flat bars directly to breaker terminals. Extension bars are attached to breaker terminals. Connect compression terminals or flat bars to the extension bars. Cable clamps are attached to breaker terminals. Connect wires directly to cable clamps. Flat bar studs will be factory installed in the horizontal position unless otherwise specified. For E0, S0, the flat bar studs in the vertical position are available on request. Please select a position code from those shown in the table below: Remarks Position code Position of flat bar studs Line side Load side RC- Vertical Horizontal RC-B Horizontal Vertical RC-C Vertical Vertical RC-D Horizontal Horizontal For S160, the studs are horizontal direction only. See page 2-6 for dimensions and tightening torques of terminal screws. Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : Semi-standard. : Custom-built. Contact us for details. : no or not available. q. See page 2-3 for details. 2-2

11 Connecting parts There are the following connecting/mounting hardware available as options: 1. Extension bars for front conection Type Number of poles pplicable breakers Min Constituent parts order qty Extension bar Screw B Screw C T2FB12L2SH /2 T2FB12L3SH 3 S160-SCF, S160-SF, S160-SCJ, S160-SJ, S160-SN Straight extension bars T2FB12LSH T2FB12L2SB 2 T2FB12L3SB 3 S160-SCF, S160-SF, S160-SCJ, S160-SJ, S160-SN Straight extension bars T2FB12LSB T2FBL3WH 3 1/ E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN Spread extension bars T2FBLWH 1 T2FBL3WB E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN Spread extension bars 1 T2FBLWB T2FBL2SH /2 T2FBL3SH 3 E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN Straight extension bars T2FBLSH T2FBL2SB 2 T2FBL3SB 3 E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN Straight extension bars T2FBLSB See page 2-6 for screws B and C. Note q: Two sets, one for the line side and one for the load side, are required per breaker. 2. Frat bar stud for rear connection Constituent parts Type Number of poles pplicable breakers Min order qty Stud bar Screw D Screw E T2RP12L2S 2 T2RP12L3S 3 S160-SCF, S160-SF, S160-SCJ, S160-SJ, S160-SN T2RP12LS T2RPL2S 2 1 T2RPL3S 3 E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN T2RPLS See page 2-6 for screws D and E. Note q: The studs can be rotated to four angular positions: 0 (horizontal), 5, 90 (vertical) and 135 degrees. Remarks Remarks 2 Mounting and Connection 2-3

12 Mounting and Connection 2Molded Case Circuit Breakers xcompression terminals Front connected type (without extension bar) Frame size () Breaker E-SF (15-50) R2-5 (R2-6) 160 S160-SCF, S160-SF, S160-SCJ S160-SJ, S160-SN 0 E0-SF, S0-SF, E0-SJ S0-SJ, S0-SN (15-50) (60-160) Nominal wire size (mm 2 ) R2-5 (R2-6) R5.5-5 (R5.5-6) R5.5-5 (R5.5-6) R8-5 (R8-6) R8-5 (R8-6) R1-5 NTMCB22-5S MP3311 (60-160) R8-8 R1-8 R22-8 MP JST38-S8 NTM38-8S R1-5 NTMCB22-5S MP3311 R8-8 R1-8 R22-8 MP JST38-S8 NTM38-8S 60-2B Note B Note 2 MELEC TM70-8 R38-8 R B Note 2-3B Note 2 CB150-8 CB80-8 CB-8 Front connected type (with extension bar) Nominal wire size (mm 2 ) Frame size () Breaker E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN R38-10 R60-10 R80-10 R-10 R CB Notes: q. Commercially made compression terminals can be used (refer to boxes) R/RD : JIS-compliant CB : JEM 1399-compliant MP : Made by Nippon MP Co., Ltd. JST : Made by Japan Solderless Terminal Manufacturing Co., Ltd. NTK : Made by Nippon Tanshi Co., Ltd. NTM : Made by Nichifu Terminal Industries Co., Ltd. MELEC : Made by Shanghai JiaMeng Electrical Equipment Co., Ltd. w. Compression terminals in box cells are made by us at Terasaki. They are available from us or our authorized agents. e. Compression terminals enclosed in parentheses are to be used as the lower terminal when two terminals are connected. 2-

13 Connection (two terminals) If a shortage of insulating occurs between the mounting plate and a terminal, use a recommended taping or insulator. When a single terminal is connected 2 Terasaki made compression terminals are used (refer to ± ø ±0.3 ø Second terminal when two terminals are connected 60-2B 80-3B -3B ø ø1.5 ø19.5 Nominal size engraved 22.5 ± ø box) ±0.5 ø Mounting and Connection Connection (one electric cable) Connection (two electric cables) If a shortage of insulating occurs, use a recommended taping or insulator. If a shortage of insulating occurs, use a recommended typing or insulator. Make connection so that the screw heads face toward the mounting surface. Make connection so that the screw heads face toward the mounting surface. 2-5

14 Mounting and Connection 2Molded Case Circuit Breakers cterminal screw sizes and standard torques Connecting types Front connection (FC) Rear connection (RC) (Flat bar stud) Screw E Rear connection (RC) (Bolt stud) Screw F Screw B Screw C Screw D Screw Type G Frame size () Breaker E-SF (1050) E-SF (60) Compression terminal Screw size () Torque (N. m) Pan head M512 Wire clamping screw Pan head M Screw size (B) Torque (N. m) Extension bar Screw size (C) Torque (N. m) Screw size (D) Torque (N. m) Screw size (E) Torque (N. m) 160 S160-SCF Wire clamping M51 Wire clamping M51 Hex head M822 Pan head M51 Hex head M823 S160-SF S160-SCJ S160-SJ (1550) S160-SCF Pan head M81 Pan head M81 Hex head M822 Hex socket head M618 Hex head M823 S160-SF S160-SCJ S160-SJ (60160) S160-SN Pan head M81 Pan head M81 Hex head M822 Hex socket head M618 Hex head M E0-SF Hex socket head M818 Hex socket head M818 Hex head M10 Hex socket head M618 Hex head M8 S0-SF E0-SJ S0-SJ S0-SN Screw size (F) Torque (N. m) Pan head M Hex head M6 nut Screw size (G) Torque (N. m) Hex. nut M Hex. nut M Wire clamping screw Pan head screw Hex socket head bolt 2-6

15 Mounting and Connection Molded Case Circuit Breakers 2vInsulation distance from the line side The insulation distance between the breaker and earthed metal parts and insulators shown in the table on the next page must be maintained to prevent arcing faults occurring due to conductive ionised gas. In addition, completely cover exposed conductors, to their roots at the breaker or to below the height protected by interpole barriers, on the line side of the breaker using insulation tube or tape, in order to provide positive ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ protection against short circuit or ground fault due to metal chipping, surge voltage, dust particles or salt. Be sure to install the interpole ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ barriers supplied with the breaker. ~~~~~~~~~~~~~~~ Insulating tube or tape Sheathed wire 2 Interpole barrier Exposed conductor Line side Load side Insulation plate Top plate (earthed metal) Interpole barrier Compression terminal Interpole barrier (Insulation tube or tape is also acceptable) Side plate Mounting and Connection B1 B2 B1 B2 B1 B2 E Insulation tube or tape D Front connection, terminal screw Front connection, extension bar Rear connection, Plug-in C. Distance from lower breaker to exposed live part of upper breaker terminal (front connection) or distance from lower breaker to end face of upper breaker (rear connection). B1. Distance from end face of breaker to top plate. B2. Distance from end face of breaker to insulation plate. C. Gap between breakers. D. Distance from side of breaker to side plate (earthed metal). E. Dimension of insulation over exposed conductors. 2-7

16 Mounting and Connection 2Molded Case Circuit Breakers vinsulation distance from the line side Insulation distance, mm (C 60 V or less) Note q Molded Case Circuit Breakers Breaker 1 2 E-SF Possible to set close Not less than the length of the bare live part Note 3 E0-SF, E0-SJ Possible to set close 50 Not less than the length of the bare live part Note 3 S160-SCF, S160-SF, S160-SCJ, S160-SJ Possible to set close Not less than the length of the bare live part Note 3 S0-SF, S0-SJ Possible to set close 50 Not less than the length of the bare live part Note 3 Notes: q. Required to allow free and uninterrupted flow of arc gases. Ensure additional clearance or insulation distance if required to perform wiring, barrier installation or electrical work or to meet the need for more insulation distance between bare live parts and grounded metal members in a switchboard or the like. w. The figures are for lower breakers. e. For front connection breakers, insulate all exposed conductors of the line side until the breaker end. If interpole barriers are packed, be sure to use the barriers; more over, insulate all exposed conductors by insulating tape or the like so that the tape overlaps with the barriers.. If using extension bars (optional), ensure the insulation distance specified for the application. 2Mounting and Connection Molded Case Circuit Breakers breverse connection The breakers are available for normal connection by default. Reverse connection is optionally allowed. See the tables below. Breaker C20V C15V C50V E-SF S160-SCF, S160-SF, S160-SCJ, S160-SJ, 160-SN E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN ON ON OFF OFF Mounting and Connection 2Molded Case Circuit Breakers nlists of breaker mounting screws Breaker Number of poles Front-connected (FC) Rear-connected (RC) Screw size Qty Screw size Qty E-SF 2,3 Pan head M65 2 Pan head M65 2 S160-SCF,S160-SF,S160-SCJ,S160-SJ,S160-SN 2,3 Pan head M61 2 Pan head M61 2 E0-SF,S0-SF,E0-SJ,S0-SJ,S0-SN 2,3 Pan head M55 2 Pan head M55 2 Pan head M55 Pan head M55 2-8

17 ccessories 3zInternally mounted accessories Connection diagrams and terminal numbers Possible combinations Ratings and operation data of auxiliary and alarm switches3-3. Shunt trip device (SHT) Undervoltage trip device (UVT) 3- xexternally mounted accessories Motor operators (MC) Toggle holder (HH) and toggle lock () External operating handles 3-10 (1) Breaker-mounted (HB) for E 3-10 (2) Breaker-mounted (field installable)(hb) for S160, E0, S (3) Door-mounted (depth adjustable) (HS) standard type3-16 () Door-mounted (depth adjustable) (HP) ordinal type Interpole barriers (B) 3-5. Terminal covers CF/CR/CS 3-26 (1) CF for front-connected breakers 3-26 (2) CR for rear-connected and plug-in breakers CS for front-connected breakers with cable clamps Terminal blocks (TF) Mechanical interlock 3-30 Slide interlock (MS) Door Flange (DF) ccessories 3-1

18 3 ccessories Molded Case Circuit Breakers zinternally mounted accessories 1. Connection diagrams and terminal numbers ccessory Combination symbol Connection diagram and terminal No. Remarks Shunt trip device (SH) With anti-burn switch Without anti-burn switch pplicable to E-SF.. Shunt trips are fitted with anti-burn switches. C1 C2 pplicable to other breakres except E- SF. Shunt trips are continuous rating without anti-burn switches. For C For DC Undervoltage trip device (UV) With UVT controller D1 controller D2 pplicable to E-SF. UVT controller is required for C UVT. See page 3-5 for the details. 12/Xb1 1/Xa1 1pc ux. SW installed. uxiliary switch (X) 11/Xc1 12/Xb1 1/Xa1 11/Xc1 12/Xb1 1/Xa1 22/Xb2 2/Xa2 21/Xc2 22/Xb2 2/Xa2 32/Xb3 3/Xa3 2/Xb /Xa 2pcs ux. SW installed. pcs ux. SW installed. 11/Xc1 21/Xc2 31/Xc3 1/Xc 92/Lb1 9/La1 larm switch (L) TRIP 91/Lc1 92/Lb1 9/La1 TRIP 02/Lb2 0/La2 TRIP 1pc larm. SW installed. 2pcs larm. SW installed. 91/Lc1 01/Lc2 2. Possible combinations Molded Case Circuit Breakers Type Number of poles q uxiliary switch larm switch Shunt trip Under voltage trip E-SF E-SF S160-SCF S160-SCF S160-SF S160-SCJ S160-SJ S160-SN E0-SF S0-SF E0-SJ S0-SJ S0-SN Notes: q: The two-pole type breaker obtained by modifying a three-pole breaker by removing the conductive part of its central pole is regarded as the same as the three-pole type. 3-2

19 3. Ratings and operation data of auxiliary and alarm switches (1) Ratings of X and L The applicable load of the switch shall be no larger than the rating and no smaller than the minimum load. Standard For microload 1 Type of breaker Voltage (V) C (V) Current () Resistive load Inductive load 2 Voltage (V) DC (V) Current () Resistive load Inductive load 2 Minimum load Voltage (V) DC (V) Current () Resistive load Minimum load E-SF DC6V m DC2V m DC6V 5m DC2V 1.m 80 0 S160-SCF, S160-SF, S160-SCJ, S160-SJ, S160-SN E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN Note: 1 This is a custom-made product. When ordering for this product, specify that it is intended for minute load use. Note: 2 The inductive load means power factor of no smaller than 0. and time constant of no larger than 7 ms. DC15V m DC5V 1m 3 (2) Operation of X and L Switch Breaker status [ON] [OFF] uxiliary switch (X) status 12/Xb 1/Xa 91/Xc 11/Xc-1/Xa Closed 11/Xc-12/Xb Open 11/Xc-1/Xa Open 11/Xc-12/Xb Closed [TRIP] 11/Xc-1/Xa Open 11/Xc-12/Xb Closed ccessories larm switch (L) status 92/Lb 9/La TRIP 91/Lc-9/La Open 91/Lc-92/Lb Closed 91/Lc-9/La Open 91/Lc-92/Lb Closed 91/Lc-9/La Closed 91/Lc-92/Lb Open 91/Lc. Shunt trip device (SH) Ratings of SHT Peak exciting current, Type of breaker Rated voltage C (V) DC (V) E-SF Peak exciting current, Type of breaker Rated voltage C (V) DC (V) S160-SCF, S160-SF, S160-SCJ, S160-SJ, S160-SN E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN Notes: (1) The permissible voltage range is from 85% to 110% of the rated voltage for C or 75% to 1% thereof for DC. Ensure that the voltage does not drop exceeding the permissible voltage range when SHT is actuated. (2) Breaker contacts usually start opening within 30 ms after the rated voltage is applied to the breaker. 3-3

20 3 ccessories Molded Case Circuit Breakers zinternally mounted accessories 5. Undervoltage trip device (UV) Ratings of UVT with Inst Type of breaker Rated voltage Power supply capacity, V Exciting current, m C (V) DC (V) E-SF 5 min 2 5 min 2 5 min S160-SCF, S160-SF, S160-SCJ, S160-SJ, S160-SN E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN Note: 1: No UVT controller is required. 2: Equipped with the UVT controller. See page 3-5 for specifications of the UVT controller. TemBreak2 UVT are available with 500±300 msec time delays. UVT controller is installed on the breaker. Rating of UVT with time delay Rated voltage Time delays: 500±300 msec. Power supply capacity, V Exciting current, m C (V) DC (V) S160-SCF, S160-SF, S160-SCJ, S160-SJ, S160-SN E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN Mounting dimensios and terminal arrangement of the UVT controller installed on the breaker 160-SCF, S160-SF, S160-SCJ S160-SJ, S160-SN E0-SF, S0-SF, E0-SJ S0-SJ, S0-SN 2P,, P , P The UVT controller is installed in the right hand side of the breaker D ON OFF D1 D UVT controller Terminal screw M3.5 C B Notes: 1. Tightening torque of terminal screws: N. m 2. pplicable lead wire size: 2.0 mm 2 max 3-

21 UVT controller for Type E-SF E-SF equipped with the C UVT need a UVT controller. The UVT controller is installed on the breaker by default. Separate installation of the controller is also available on request. lso a UVT controller (type XCU1D) with a time delay of less than 500 ms is available on request. UVT controller connection diagram UVT controller installed on the breaker UVT controller installed external to the breaker Breaker or fuse Line side Breaker or fuse Line side UVT controller P2 ON P1 UC2 OFF UC1 Mounting dimensios and terminal arrangement of the UVT controller installed on the breaker UVT controller Note: If the UVT controller is installed on the breaker, terminals UC1 and UC2 are factory wired. P2 P1 UC2 UC1 Lead wire (50 mm long) ON OFF Outline of the UVT controller installed external to the breaker 3 ccessories UVT controller 38 terminal screw M P2 P1 UC2 UC1 ON OFF Mounting hole ø Notes: 1. Tightening torque of terminal screws: N. m 2. pplicable wire size: 2.0 mm 2 max Terminal screw M3.5 Support 3-5

22 ccessories Molded Case Circuit Breakers 3xExternally mounted accessories 1. Motor operators (MC) Motor driven type Key lock (optional) Voltage presence LED indication Operating handle Lock plate Ratings and Specifications Type of breaker Rated operational voltage 1 Peak steady-state/ starting current, 2 T2MCL E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN C-110V C V C230-20V DC2V DC8V DC-110V DC V C-110V.5/8 C V C230-20V DC2V DC8V DC-110V DC V /8 3.5/7 18/26 12/18 2.2/6 2.2/5.5 Operation method Motor driven (direct drive system) Operating time, s ON 0.1 at rated voltage OFF/RESET 0.1 Operating switch ratings V 0.1 (Open voltage/current: V/ m) Power supply required 300V or higher Dielectric withstand voltage (for one minute) C1500V (C 0 V for DC 2/8 V) Weight 1.kg Notes: : Permissible operating range is 85 to 110%. power transformer is available as option for C380V or C00-60V. : The currents shown are the maximum values at the maximum rated operational voltage. : The operating time is the value when the rated operational voltage is supplied. llow a longer time for the motor operator to complete the operation. : The motor operator is of a short time duty. Do not subject it to more than 10 continuous ON-OFF operations. If this occurs, allow the motor operator to cool for at least 15 minutes. : When the rated operational voltage is DC2V the open voltage will be DC22V. Features Installation and removal ease Simply rotate two knobs allows the motor operator to be installed on or removed from the breaker. High-speed, stable actuation The operating time as short as up to 0.1 second makes it possible to use the motor operators for synchronized closing of breakers. Silent operation T2MCL use a direct drive system, providing operational silence. Lock-in off capability This capability allows the breaker to be padlocked in the OFF state. Up to thee padlocks with a 5 to 8 mm hasp diameter can be used. Padlocks are not supplied. 3-6

23 Motorized operation The motor operator has an input-signal self-hold circuit; closing the ON or OFF switch (see circuit diagrams shown bellow) momentarily allows activating the motor operator. To reset the tripped breaker to the OFF position, close the OFF (RESET) switch. The voltage presence LED indication is on when the power is supplied to the motor operator. uto reset feature (optional) The auto reset feature allows the breaker to be automatically reset approx. 1.5 seconds after the breaker trips open. This option contains auto-reset switches and does not require to use auxiliary or alarm switches installed in the breaker. Note : that after the thermal OCR trips a thermal-magnetic breaker, the breaker cannot be immediately closed though it can be auto-reset. Wait for a few minutes after the tripping and provide a close signal to the breaker. This option resets the tripped breaker automatically, regardless of the cause of the tripping. Manual operation Pull the operating handle out. Rotating the handle counterclockwise turns ON the breaker and clockwise turns OFF or resets the breaker. 3 Operation precautions 1. Ensure that the actual operation voltage ranges from 85% to 110% of the rated one. 2. Use operation switches whose ratings and power capacity is as specified in the Ratings and Specifications table on the previous page. 3. Use noise filters if the control power supply of the motor operator is shared by peripheral devices. Otherwise, power supply noise may cause malfunction of the peripheral devices.. When the motors are used in conjunction with the mechanical interlock the electrical interlock should be provided between the motors in order to avoid the simultaneous closing. The followings are the available electrical interlock cables. ccessories Interlock cables Order codes T2MML05 T2MML15 T2MM0L06 T2MM0L21 T2MM0S06 T2MM0S21 Length 500mm 1500mm 600mm 2mm 600mm 2mm Remarks for the electrical interlock between T2MC12 and T2MC/L. for the electrical interlock between T2MC0 and T2MC80. for the electrical interlock between T2MC0 and T2MC12//L. Control circuit diagrams of motor operators T2MCL P1(+) DS OFF(RESET) ON + The + and symbols indicate the Uc polarities of DC-rated motor operators. OFF ON COM Control power circuit ON/OFF control circuit LED Motor drive circuit M P2( ) E 3-7

24 ccessories Molded Case Circuit Breakers 3xExternally mounted accessories 1. Motor operators (MC) Motor driven type ON-OFF indicator (XMB1) Ratings and Specifications Control circuit diagrams of motor operators Series/type of breaker Rated operational voltage uto reset XMB1 E-SF C-110V C V DCV DC110V Optional Non Notes: Ensure that the actual operation voltage is within the following range:85% to 110% of the C rated voltage, or 75% to 110% of the DC rated voltage In case the rated operation voltage is C 380 V or C 00 to 60 V, optional power supply transformers are available on request. uto reset require to use auxiliary switch (1b) installed in the breaker. If the number of auxiliary switches is insufficient, actuate an external relay via an auxiliary switch (1a) and use the relay contact (1b) for auto reset. The currents shown are the maximum values at the maximum rated operational voltage. XMB1 For C and DC D C SOURCE OFF RESET B UTO RESET SW (OPTION) ON Peak steady-state/ starting current, C-110V C V DCV DC110V Operation method Operating time, s ON at rated voltage OFF/RESET Operating switch ratings Power supply required Dielectric withstand voltage (for one minute) Weight 2.0/.5 1.0/2.0 Motor driven V, 5 V or higher C0V 1.8 The operating time assume the motor operator is supplied with the rated operation voltage. Longer operating time will be required under actual operating conditions. The motor operator is short-time rated. The number of continuous switching (ON-OFF) cycles must not exceed 10. fter any 10 continuous switching cycles, provide a pause of at least 15 minutes to the motor operator for cooling. Can be custom-made on request. The outline dimensions of the motor operator will be larger. n auto-reset switch cannot be used. Contact us for details. E X2 X R LIMIT SW X1 Built in C V rated motor operators. X: Relay, M: Motor 3-8 Motorized Operation Breaker ON Operating the ON switch energises the motor which turns ON the breaker. When the breaker is energised the limit switch operates to de-energise the motor. Note: This is not a self-holding type. Gives a signal exceeding the operating time. Breaker OFF Operating the OFF/RESET s witch energises the motor which turns OFF the breaker. When the breaker is energised the limit switch operates to de-energise the motor. Note: This is not a self holding type. Gives a signal exceeding the operating time. Breaker RESET Operate the OFF/RESET switch to reset the tripped breaker. When the breaker is reset (OFF) the limit switch operates to de-energise the motor. Note: This is not a self holding type. Gives a signal exceeding the operating time. utomatic Reset (Optional) The automatic reset feature can be incorporated by adding the breake s auxiliary switch contact (b-contact) in parallel with the OFF/RESET control switch. Note: When the cause of the trip has not been removed the ON-TRIP-RESET-ON operation is repeated. Therefore, do not use the ON operation switch which is normally closed. Manual Operation To operate the mechanical test fa cility of the motor operator pump the manual lever left and right approximately 20 times. Note: This facility must not be used for ON load operations. Lock in OFF position The breaker can be padloked in the OFF position. (padlock not supplied). CUTIONRY NOTES If the motor operator is turned ON with the breaker OFF and the UVT de-energised, apply the power and complete one ON-OFF operation. (The breaker cannot be turned ON). Then complete one ON operation again (The breaker can be turned ON) When the breaker is ON and is then tripped, the ON/OFF indicator on the motor operator will be indicating ON until the breaker is reset. Note: The breaker s condition may differ. Note: llow several minutes to cool when a thermal-magnetic breaker is tripped by a thermal overload trip, then reset the breaker.

25 2. Toggle holder (HH) and toggle lock () Toggle holder (HH) Simply fitting the toggle holder onto the breaker toggle disables breaker operation without using padlocks. Toggle lock () The toggle lock is a tool that locks the breaker on or off. When an overcurrent occurs, the breaker will trip even if the breaker toggle is locked in the ON position. (Use commercially available padlocks). Toggle holders/toggle locks Type of breaker Toggle holder Order codes Marking codes Figure Order codes Toggle lock Marking codes Figure E-SF TKB-1DH E160-SF, S160-SCF, S160-SF, S160-SCJ, S160-SJ, S160-SN E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN T2HHL T2HHL 2 T2L T2L 3 Notes: 1. hole must be drilled in the breaker toggle. Please state with toggle lock () when ordering. Fig. 1 Red 3 OFF O N ccessories Fig. 2 Red Fig. 3 Red ø5 Padlock Up to three padlocks can be used 3-9

26 ccessories Molded Case Circuit Breakers 3xExternally mounted accessories 3. External operating handles 3-1. Breaker-mounted The external operating handle is a tool that allows the breaker installed in a switchboard to be operated from outside. The breaker-mounted type external operating handle is designed to be mounted directly to the breaker body. Outer view Breaker mounting direction The ON and OFF positions of the handle and the positions of drilled holes in the panel do not need to be changed depending on the breaker mounting direction. The upper power supply type is standard. If a non-standard type is required, state the type when ordering. R : Right power supply type U: Upper power supply type (standard) L: Left power supply type ON OFF Power supply Load Power supply Power supply Load Load Mounting instructions The external operating handle has not been mounted on the breakers. For details on how to mount the handle, see the Operating Instructions packaged with the product. [1] Mounting of external operating handle assembly [2] Installation of handle escutcheon and latch plate Secured to backing plate (TFJ21XH) Make sure that the breaker is in the OFF position. Put the external operating handle assembly onto the breaker in place so that the breaker toggle is engaged with the slide lever of the assembly. Secure the assembly together with the breaker to the backing plate. For a change in mounting direction, see the Operating Instructions packaged with the product. Drill holes in the panel according to the panel cutout dimensions. Sandwich the panel between the handle escutcheon and latch plate and temporarily tighten using the supplied screws. Close the panel. Make adjustment so that the gap between the handle assembly and handle escutcheon is even and the assembly is not inclined against the breaker. Slide lever Breaker Toggle Gap (Incorrect) Breaker Handle frame Handle escutcheon Hook holder Panel Handle escutcheon Panel lock mechanism The external operating handle keeps the panel door locked when in the ON position. There are two types, RESET, Open and OFF, Open. (1) Reset, Open (Standard type) The handle is turned to the RESET/OPEN COVER position to open the panel door. Handle escutcheon Breaker Safety interlock (Standard) The safety interlock prevents the breaker from turning ON as long as the panel is open. This interlock can be released using the hook lever. (2) OFF, Open The handle is turned to the OFF position to open the panel door Panel lock release knob The release knob enables the panel door to be opened with the handle in the ON position. To release: turn the release knob in the direction of anti-clockwise with a flat-bladed screwdriver. Handle Panel lock release Hook lever

27 H>0 Protection degree EC IP30 standard specification IP50 optional, with a dust proof packing IP55 special specification Toggle lock mechanism Padlock (Standard) This mechanism allows the breaker to be padlocked in the ON or OFF position. Padlocks are not supplied. Up to three padlocks can be installed. Dia. Padlock dimensions (mm) Type of handle Dia. TFJ21XH 13 min ø3.5-6 Dustoproof packing Dustproof packing for IP50 (optional) mm Type of handle Type of dustproof packing B C TFJ21XH Dustproof packing / C B Padlock 3 Possible combinations of breaker and external operating handle Type of external operating handle TFJ21XH Order code E-SF To be stated when ordering TFJ21XH U R 3 B Type of breaker ccessories Type of external operating handle Breaker mounting direction Panel lock Protection degree Colour TFJ21XH U: Upper power supply type R: Right power supply type L: Left power supply type R : RESET open F : OFF open 3 : IP30 5 : IP50 55 : IP55 (special spec.) B : Black handle (Black base) R : Red handle (Yellow base) : standard specification TFJ21XH pplicable breaker types E-SF Mounting screw M75, 2 pcs SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions Panel cutout dimensions Relative positions of the hinge and handle as seen from the Plate thickness load side of the breaker 105 Breaker Panel Handle escutcheon 105 Hook lever, SL ø90 78 H>0 61 max Panel lock release Lock lever 3 106±2 78 -ø15 (5H+) min (5H+) min 3-11

28 3ccessories Molded Case Circuit Breakers 3. External operating handles 3-2. Breaker-mounted The external operating handle is a tool that allows the breaker installed in a switchboard to be operated from outside and complies with IEC The breaker-mounted type external operating handle is designed to be mounted directly to the breaker body. Outer view xexternally mounted accessories Mounting instructions The external operating handle has not been mounted on the breakers. For details on how to mount the handle, see the Operating Instructions packaged with the product. Make sure that the breaker is in the OFF position. Put the external operating handle assembly onto the breaker in place so that the breaker handle is engaged with the handle catch of the assembly. Tighten the screw to secure the handle assembly. Slide lever Breaker handle Screw OFF SIDE Screw Drill holes in the panel according to the panel cutout dimensions. Sandwich the panel between the handle escutcheon and latch plate and temporarily tighten using the supplied screws. Close the panel. Make adjustment so that the gap between the handle assembly and handle escutcheon is even and the assembly is not inclined against the breaker. Dustproof packing (optional) Gap (Incorrect) Breaker Handle frame Handle escutcheon Handle escutcheon Breaker Breaker mounting direction The ON and OFF positions of the handle and the positions of drilled holes in the panel do not need to be changed depending on the breaker mounting direction. The upper power supply type is standard. If a non-standard type is required, state the type when ordering. R : Right power supply type U: Upper power supply type (standard) Power supply L: Left power supply type Load Power supply Power supply Load Load For a change in mounting direction, see the Operating Instructions packaged with the product. 3-12

29 Panel lock mechanism The external operating handle keeps the panel door locked when in the ON position. There are two types, RESET, Open and OFF, Open. (1) Reset, Open (Standard type) The handle is turned to the RESET/OPEN COVER position to open the panel door. (2) OFF, Open The handle is turned to the OFF position to open the panel door. Panel lock release knob The release knob enables the panel door to be opened with the handle in the ON position. To release: turn the release knob in the direction of anti-clockwise with a flat-bladed screwdriver. Toggle lock mechanism Padlock (Standard) This mechanism allows the breaker to be padlocked in the OFF position. Padlocks are not supplied. Up to three padlocks can be installed. Dia. Padlock dimensions (mm) Type of handle Dia. T2HB 13 min ø5.5-8 Protection degree EC Safety interlock (Standard) The safety interlock prevents the breaker from turning ON as long as the panel is open. This interlock can be released using the hook lever. Possible combinations of breaker and external operating handle IP30 IP50 IP55 standard specification optional, with a dust proof packing special specification ccessories Type of breaker Type of external operating handle S160-SCF, S160-SF, S160-SCJ, S160-SJ, S160-SN T2HB16L E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN T2HBL Note 1 : Key lock is not available. To be stated when ordering Order code T2HB16L U R 3 B T Type of external operating handle Breaker mounting direction Panel lock Protection degree Colour Key lock T2HB16L T2HBL U: Upper power supply type R : RESET open R: Right power supply type F : OFF open L: Left power supply type : standard specification 3 : IP30 5 : IP50 S : IP55 (special spec.) B : Black handle (Black base) R : Red handle (Yellow base) T : without key lock 3-13

30 ccessories Molded Case Circuit Breakers 3xExternally mounted accessories 3. External operating handles Outline dimensions T2HB16L pplicable breaker types S160-SCF S160-SJ S160-SF S160-SN S160-SCJ SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions Panel cutout dimensions ±2 60 -ø10 ON Handle escutcheon 75 Panel lock release ø Hook lever Panel Plate thickness Positions of the hinge and handle as seen from the load side of the breaker. Ensure that the hinge is positioned in the area

31 SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line T2HBL pplicable breaker types E0-SF S0-SF E0-SJ S0-SJ S0-SN Outline dimensions Panel cutout dimensions ± ON Handle escutcheon Panel lock release ø65 -ø10 3 ccessories Hook lever Panel Plate thickness Positions of the hinge and handle as seen from the load side of the breaker. Ensure that the hinge is positioned in the area

32 ccessories Molded Case Circuit Breakers 3xExternally mounted accessories 3. External operating handles 3-3. Door-mounted (depth adjustable) (HS) standard type Door-mounted type external operating handles allow breakers installed in control centers or switchboards to be manually operated from outside and complies with IEC This handle assembly consists of an operation mechanism section which is to be installed in the breaker body, a handle section which is to be installed in a panel and a square shaft which couples both the sections. Outer view Square shaft Operating unit Shaft support Gasket for IP65 Handle cover Operating handle Operation direction of handles Rotate the operating handle clockwise to turn the breaker on. OFF ON Breaker mounting direction The ON and OFF positions of the handle and the positions of drilled holes in the panel do not need to be changed depending on the breaker mounting direction. Horizontal mounting / ON to move the breaker handle right Vertical mounting / ON to move the breaker handle up Line (ON) Horizontal mounting / ON to move the breaker handle left Line (ON) Line (ON) Rotate clockwise to turn the breaker ON 3-16

33 Panel lock mechanism The external operating handle keeps the panel door locked when in the ON position. There is OFF open type only. OFF open type The handle is turned to the OFF position to open the panel door. Panel lock release button The release button enables the panel door to be opened with the handle in the ON position. To release: push the release button on the side of the operating handle with a flat-bladed screwdriver. Toggle lock mechanism Padlock (Standard) This mechanism allows the breaker to be padlocked in the OFF position. Padlocks are not supplied. Up to three padlocks can be installed. Dia Padlock dimensions (mm) Type of handle Dia. T2HS16L/L 13 min ø5-8 Pad locking lever 3 Protection degree EC IP55 standard specification IP65 special specification : Special handle unit and gasket are used for IP65. Dimensions of square shafts available There are the following shaft dimensions available. Select an appropriate shaft depending on the mounting position of the breaker. Cut the shaft to an appropriate length if required. Coat the cut end faces of the shaft with an anti-corrosion paint. ccessories LB L LB Shafts order codes L (mm) LB (mm) Possible combinations of breaker and external operating handle E-SF Type of breaker Type of external operating handle T1HS10X T2PS Shaft support (optional) The shaft support makes easy to insert to the operating handle when the panel door is closed. S160-SCF, S160-SF, S160-SCJ, S160-SJ, S160-SN E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN T2HS16L T2HSL Key fitting facility (optional) Key fitting facility is available for Castell FS1. Contact us for the details of mounting dimension. To be stated when ordering Order code T2HS16L F 5 B P N Type of external operating handle Panel lock Protection degree Colour Pad locking lever Optional T1HS10X T2HS16L T2HSL F : OFF open 5 : IP55 6 : IP65 B : Gray handle (Black base) R : Red handle (Yellow base) P : Plastic M : Metal N : No option K : Key fitting facility S : With shaft support W: Key fitting facility and shaft support : standard specification 3-17

34 ccessories Molded Case Circuit Breakers 3xExternally mounted accessories 3. External operating handles Outline dimensions T1HS10X SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions 19.5±2 151 Panel thickness ø78 C L C L Panel cutout dimensions Positions of the hinge and handle as seen from the load side of the breaker. Ensure that the hinge is positioned in the area B M5 (Nominal size of llen key applicable: 2.5) ø31-ø C L 9 9 -ø pplicable breaker types ±2 B±0.5 E-SF 182 min max. 358 Note q: Min (minimum) means the minimum possible distance from the panel surface to the breaker mounting surface, which can be formed by cutting the square shaft. Max (maximum) means the maximum distance of the same section, which is formed with no cutting of the square shaft. : Distance from the panel surface to the breaker mounting surface B: Length of the square shaft used 3-18

35 Outline dimensions T2HS16L 19.5±2 SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions 1.5 Panel B Panel cutout dimensions M5 (Nominal size of llen key applicable: 2.5) 0 ø31-ø37 -ø Positions of the hinge and handle as seen from the load side of the breaker. Ensure that the hinge is positioned in the area. pplicable breaker types ±2 B±0.5 S160-SCF S160-SF S160-SCJ 175 min. 80 S160-SJ S160-SN 53 max. 358 Note q: Min (minimum) means the minimum possible distance from the panel surface to the breaker mounting surface, which can be formed by cutting the square shaft. Max (maximum) means the maximum distance of the same section, which is formed with no cutting of the square shaft. : Distance from the panel surface to the breaker mounting surface B: Length of the square shaft used ccessories Outline dimensions T2HSL Outline dimensions Panel 19.5± B Panel cutout dimensions M5 (Nominal size of llen key applicable: 2.5) ø31-ø37 28 Positions of the hinge and handle as seen from the load side of the breaker. Ensure that the hinge is positioned in the area ø pplicable breaker types ±2 B±0.5 E0-SF S0-SF E0-SJ 175 min. 80 S0-SJ S0-SN 53 max. 358 Note q: Min (minimum) means the minimum possible distance from the panel surface to the breaker mounting surface, which can be formed by cutting the square shaft. Max (maximum) means the maximum distance of the same section, which is formed with no cutting of the square shaft. : Distance from the panel surface to the breaker mounting surface B: Length of the square shaft used 3-19

36 OFF OPEN RESET TRIP ON OFF OPEN RESET TRIP ON OFF OPEN RESET TRIP ON 3 ccessories Molded Case Circuit Breakers xexternally mounted accessories 3. External operating handles 3-. Door-mounted (depth adjustable) (HP) ordinal type Door-mounted type external operating handles allow breakers installed in control centers or switchboards to be manually operated from outside and complies with IEC This handle assembly consists of an operation mechanism section which is to be installed in the breaker body, a handle section which is to be installed in a panel and a square shaft which couples both the sections. Outer view Operation direction of handles Rotate the operating handle clockwise to turn the breaker on. Rotate clockwise to turn the breaker ON Breaker mounting direction The ON and OFF positions of the handle and the positions of drilled holes in the panel do not need to be changed depending on the breaker mounting direction. Horizontal mounting / ON to move the breaker handle right Vertical mounting / ON to move the breaker handle up Horizontal mounting / ON to move the breaker handle left Line (ON) Line (ON) Line (ON) 3-20

37 Panel lock mechanism The external operating handle keeps the panel door locked when in the ON position. There are two types, RESET, Open and OFF, Open. (1) Reset, Open (Standard type) The handle is turned to the RESET/OPEN COVER position to open the panel door. (2) OFF, Open The handle is turned to the OFF position to open the panel door. Panel lock release knob The release knob enables the panel door to be opened with the handle in the ON position. To release: turn the release knob in the direction of anti-clockwise with a flat-bladed screwdriver. Toggle lock mechanism Padlock (Standard) This mechanism allows the breaker to be padlocked in the OFF position. Padlocks are not supplied. Up to three padlocks can be installed. Dia Padlock dimensions (mm) Type of handle Dia. T2HP 13 min ø5.5-8 Key lock (Optional) Key locking is possible in the OFF position. 3 Dimensions of square shafts available There are the following shaft dimensions available. Select an appropriate shaft depending on the mounting position of the breaker. Cut the shaft to an appropriate length if required. Coat the cut end faces of the shaft with an anti-corrosion paint. ccessories LB Protection degree EC L LB IP5 IP65 standard specification special specification Shafts order codes L (mm) LB (mm) T2PS1 T2PS2 T2PS3 T2PS To be stated when ordering Order code Type of external operating handle Panel lock Protection degree Colour Key lock T1HP10X T2HP16L T2HPL R : RESET open F : OFF open 5 : IP5 6 : IP65 B : Black handle (Black base) R : Red handle (Yellow base) W : with key lock T : without key lock : standard specification Possible combinations of breaker and external operating handle Type of breaker Type of external operating handle E-SF S160-SCF, S160-SF, S160-SCJ, S160-SJ, S160-SN E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN T1HP10X T2HP16L T2HPL 3-21

38 3 ccessories Molded Case Circuit Breakers xexternally mounted accessories 3. External operating handles Outline dimensions T1HP10X SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions D ON Handle escutcheon TRIP 105 OFF OPEN RESET Panel cutout dimensions 78 Panel lock release Key for key lock (optional) B C Panel M5 (Nominal size of llen key applicable: 2.5) Positions of the hinge and handle as seen from the load side of the breaker. Ensure that the hinge is positioned in the area. 78 LC ø ø pplicable breaker types B C D Square shaft applicable Shaft support E-SF 236min T2PS1 0max max T2PS2 50max T2PS3 550max T2PS Note q: Min (minimum) means the minimum possible distance from the panel surface to the breaker mounting surface, which can be formed by cutting the square shaft. Max (maximum) means the maximum distance of the same section, which is formed with no cutting of the square shaft. : Distance from the panel surface to the breaker mounting surface B: Length of the tube used to cover the square shaft C: Length of the square shaft used D: Distance from the tip of the shaft support to the breaker mounting surface 3-22

39 Outline dimensions T2HP16L SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions D ON Handle escutcheon TRIP 105 OFF OPEN RESET Panel lock release Panel cutout dimensions Key for key lock (optional) B Panel C M5 (Nominal size of llen key applicable: 2.5) ø10 LC ø Positions of the hinge and handle as seen from the load side of the breaker. Ensure that the hinge is positioned in the area ccessories pplicable breaker types B C D Square shaft applicable Shaft support S160-SCF S160-SF S160-SCJ 229 min T2PS1 S160-SJ S160-SN 23 max max T2PS2 3 max T2PS3 53 max T2PS Note q: Min (minimum) means the minimum possible distance from the panel surface to the breaker mounting surface, which can be formed by cutting the square shaft. Max (maximum) means the maximum distance of the same section, which is formed with no cutting of the square shaft. : Distance from the panel surface to the breaker mounting surface B: Length of the tube used to cover the square shaft C: Length of the square shaft used D: Distance from the tip of the shaft support to the breaker mounting surface 3-23

40 3 ccessories Molded Case Circuit Breakers xexternally mounted accessories 3. External operating handles Outline dimensions T2HPL SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions D Handle escutcheon ON TRIP 105 OFF OPEN RESET Panel lock release Key for key lock (optional) Panel C B M5 (Nominal size of llen key applicable: 2.5) Panel cutout dimensions 78 Positions of the hinge and handle as seen from the load side of the breaker. Ensure that the hinge is positioned in the area. 78 LC ø ø pplicable breaker types B C D Square shaft applicable Shaft support E0-SF S0-SF E0-SJ 229 min T2PS1 S0-SJ S0-SN 23 max max T2PS2 3 max T2PS3 53 max T2PS Note q: Min (minimum) means the minimum possible distance from the panel surface to the breaker mounting surface, which can be formed by cutting the square shaft. Max (maximum) means the maximum distance of the same section, which is formed with no cutting of the square shaft. : Distance from the panel surface to the breaker mounting surface B: Length of the tube used to cover the square shaft C: Length of the square shaft used D: Distance from the tip of the shaft support to the breaker mounting surface 3-2

41 . Interpole barriers (B) Interpole barriers serve to enhance electrical insulation between poles and prevent short-circuit due to electrically conductive foreign matter. Combined use of interpole barriers and terminal covers (standard type) is not possible. 2 P 3 P P B Slide interpole barriers into the grooves located on the breaker. N 3 Black To be stated when ordering Please state the type when ordering. One set contains two barriers. Caution: Be sure to use the interpole barriers supplied with the breaker in order to prevent accidents. B ccessories Types and dimensions of interpole barriers, units in mm Types of breakers Type Interpole barrier Code E-SF TQQ-2CC S160-SCF, S160-SF, S160-SCJ S160-SJ, S160-SN T2B16L3SH E0-SF, S0-SF, E0-SJ T2BL3SH T2BLS S0-SJ, S0-SN Note: Lime side interpole barriers are supplied as standard for all front connected breakres. B 3-

42 ccessories Molded Case Circuit Breakers 3xExternally mounted accessories 5. Terminal covers CF/CR/CS Terminal covers prevent live parts of the breaker from being exposed to the external environment. There are three types of terminal covers available: CF for front-connected breakers, CR for rear-connected and plug-in breakers, and CS for front-connected breakers with cable clamps. Select appropriate terminal covers depending on the type and application of the breaker. (1) CF for front-connected breakers C D B Plug-in mounted version This version can be mounted simply by being plugged in the breaker body. ø Hole for Megger measurement (at each terminal) To be stated when ordering Please state the order codes in the table below. One set includes one terminal cover for the ON side and one for the OFF side. Types and dimensions of terminal covers, units in mm CF for front-connected breakers Terminal cover B C D Colour of cover Types of breakers G:Gray Size Note: Order codes 1 Marking codes 2 poles 3 poles poles 2/3 poles poles 2/3 poles poles 2/3 poles poles C :Clear E-SF XPR1G Large G XPR1C C Small TPT1G G TPT1C C S160-SF, S160-SCJ T2CF16LSLNG Large G S160-SJ, S160-SN T2CF16LSLNC C Small T2CF16LSSNG G T2CF16LSSNC C S160-SCF T2CF16LSLNG Large G T2CF16LSLNC C Small T2CF16LSSNG G T2CF16LSSNC C E0-SF, S0-SF T2CFLSSNG Small G T2CFLSS E0-SJ, S0-SJ, S0-SN T2CFLSSNC C Large T2CFLSWNG G T2CFLSW T2CFLSWNC C Large T2CFLSLNG G T2CFLSL T2CFLSLNC C Notes:. The asterisk indicates the number of poles. Please state the number of poles at the asterisk position when ordering.. pplicable to 3-pole breakers with spread extension bars. Mounting version Plug-in Screwmounted mounted 3-26

43 (2) CR for rear-connected CS for front-connected breakers with cable clamps Fig.1 Fig.2 B C D E C D B B ø Hole for Megger measurement (at each terminal) 3 To be stated when ordering Please state with CR if ordering along with the breaker. Please state the order codes in the table below if ordering separately from the breaker. One set includes one terminal cover for the ON side and one for the OFF side. ø Hole for Megger measurement (at each terminal) Plug-in mounted version This version can be mounted simply by being plugged in the breaker body. ccessories Types and dimensions of terminal covers, units in mm CR for rear-connected Types of breakers Terminal cover Order codes 1 Marking codes B 2 poles 3 poles poles 2/3 poles poles B' C 2/3 poles poles 2/3 poles poles D Colour of cover G: Gray Figure S160-SF, S160-SCJ, S160-SJ S160-SN T2CR12LSG G S160-SCF T2CR12LSG G 1 E0-SF, S0-SF, E0-SJ T2CRLSG T2CRL G 1 S0-SJ, S0-SN 1 Terminal cover B E C D (To Colour of cover Types of breakers Order codes 1 Marking codes 2 poles 3 poles poles 2/3 poles poles screw Figure 2/3 poles poles 2/3 poles poles G: Gray head) E-SF XPS1G G 2 Notes:. The asterisk indicates the number of poles. Please state the number of poles at the asterisk position when ordering. One set includes one terminal cover fot the ON side and one for the OFF side. CS for front-connected breakers with cable clamps Types of breakers Order codes 1 Terminal cover Marking codes 3 poles poles B B' C D Colour of cover G: Gray Figure S160-SCJ, S160-SJ, S160-SN T2CS12LSG T2CS12LS G 1 E0-SF, S0-SF, E0-SJ S0-SJ, S0-SN T2CSLSG T2CSLS G 1 Notes:. The asterisk indicates the number of poles. Please state the number of poles at the asterisk position when ordering. One set includes one terminal cover fot the ON side and one for the OFF side. 3-27

44 3 ccessories Molded Case Circuit Breakers xexternally mounted accessories 6. Terminal blocks (TF) 6 terminals Vertical leading type with frame Mounting position/typical terminal arrangement Left terminal arrangement U U S S Leading direction 3/ poles ON Right terminal arrangement Ex. 1 Ex. 2 Ex. 3 Ex. Xb1 Xa1 Xc1 Lb1 Xb2 Xa2 Xc2 Xb Dimensions, mm Frame size () Types of breakers B C D E-SF Notes: : Terminal block cannot be mounted on the breaker which is equipped with the motor operator. 1) Tightening torque of M3.5 terminal screws: N. m 2) pplicable wire size: 1.mm 2 max (Vinyl-coated wire) OFF La1 Xa1 U 7.5 Left terminal arrangement S Leading direction Ex. 1 Ex. 2 Ex. 3 Ex. Xb1 Xb poles Lc1 M screw Xc1 Terminal cover (clear) 0 Xa1 Xa2 U S Xc1 Lb1 Xc2 Xb ON 90 La1 Xa1 OFF Lc1 Xc Leading direction Terminal cover (clear) 6 terminals Vertical leading type with 160 frame Mounting position/typical terminal arrangement Left terminal arrangement Ex. 1 3/ poles ON OFF Right terminal arrangement Ex. 1 Ex Dimensions, mm Types of breakers S160-SCF (2/3/ poles) 9 S160-SF, S160-SCJ, S160-SJ, S160-SN (3/ poles) 9 Notes: 1) Tightening torque of M3.5 terminal screws: N m 2) pplicable wire size: 2.0mm 2 max 18 Terminal cover (clear) poles Right terminal arrangement ON OFF 6 67 Ex. 1 Ex Terminal cover (clear)

45 6 terminals Vertical leading type with 0 frame Mounting position/typical terminal arrangement Dimensions, mm Types of breakers E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN 7 3/ poles Notes: 1) Tightening torque of M3.5 terminal screws: N m 2) pplicable wire size: 2.0mm 2 max Left terminal arrangement Ex. 1 Ex. 2 La1 La1 Lb1 Lb1 Lc1 Lc1 Xc2 Xc1 Xc1 Xb2 Xb1 Xb1 Xa2 Xa1 Xa1 ON OFF 6 67 Right terminal arrangement Ex. 1 Ex. 2 Ex. 3 La2 Lb2 Lc2 La2 Lb2 Lc2 Xc3 Xb3 Xa3 C2 C1 Xc3 Xc Xb3 Xb Xa3 Xa pieces of terminal blocks can be fitted side by side. Terminal cover (clear) ccessories 3-29

46 3 f ccessories Molded Case Circuit Breakers xexternally mounted accessories 7. Mechanical interlock Slide interlock (MS) The slide interlock provides a mechanical interlock between two breakers so that only one of the two can be closed. Moving the slide on the front of the breaker left and right allows activation or deactivation of the interlock. R h g SL h g d a d e R C SL SL a b k r r m m f Dimensions mm SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Types of breakers Interlock Order codes Number of poles a b c d e f g h k m R R E-SF XLF Notes: 1 : Please order with the breakers. (1) The interlock cannot be applied to breakers equipped with a terminal block, UVT controller or OCR controller. (2) See the outline dimensions of the breaker for the drilling plan. P R SL d a d e R C a b k Slide knob stroke Slide knob stroke 3-30

47 Dimensions mm Types of breakers S160-SCF, S160-SF, S160-SCJ S160-SJ, S160-SN Number of poles Breaker connection method Interlock Order codes 3 FC,RC T2MS16L3SF SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line FC,RC T2MS16LSF Panel cutout (front view) P R1 R The cutout dimensions allow for a side clearance of 1.0 mm from the bank of the breaker ccessories Drilling plan (front view) M 0.7 Tapped hole M 0.7 Tapped hole

48 3 ccessories Molded Case Circuit Breakers xexternally mounted accessories 7. Mechanical interlock Dimensions mm SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Types of breakers E0-SF, S0-SF, E0-SJ S0-SJ, S0-SN Number of poles Breaker connection method Interlock Order codes 3 FC,RC T2MSL3SF FC,RC T2MSLSF Panel cutout (front view) 52 P R1 52 R1 The cutout dimensions allow for a side clearance of 1.0 mm from the bank of the breaker Drilling plan (front view) M 0.7 Tapped hole M 0.7 Tapped hole

49 8. Door Flange (D.F) Door flanges are recommended to be used to cover the cutout of a switchboard panel. Breaker outline M3 0.5 Flat head screw Panel Panel drilling plan C L C L C L tapped hole Dimensions mm Types of breakers Ordr codes B C D E F G H Min Max Min Max Min Max d t 3 E-SF X M S160-SCF, S160-SF, S160-SCJ S160-SJ, S160-SN E0-SF, S0-SF, E0-SJ, S0-SJ, S0-SN T2DF M T2DF M ccessories 3-33

50

51 Characteristics and Outline Dimensions Molded Case Circuit Breakers E-SF -2 E160-SF - S160-SCF, S160-SF -6 E0-SF, S0-SF -8 S160-SCJ, S160-SJ -10 E0-SJ, S0-SJ -12 S160-SN -1 S0-SN -16 Characteristics and Outline Dimensions -1

52 Type Number of poles Ratings Rated current, Calibrated at 0 C Rated insulation voltageu i V C 690 Rated impulse withstand voltage U imp kv Utilization Category Rated breaking capacity, k 6 IEC C 690V I cu /I cs (sym) 500V 0V 15V 380V 20V DC 0V 1V Rated short time withstand current, k Weight (' marked standard type) kg Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread extension bars Cable clamps ' Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug5B (PG) DIN rail mount Clip-in chassis mount ccessories (optional) Symbol Motor operator External operating Breaker-mounted handle Door-mounted (variable depth) Toggle extension Mechanical interlock Slide type Toggle holder Toggle lock Terminal cover For front-connected For rear-connected and plug-in For cable clamps Interpole barrier Terminal block for lead Door flange Standard specifications Overcurrent trip mechanism Trip button (color) Handle position indication (ON: Red, OFF: Green) Suitability for isolation CE marking Externally mounted Characteristics and Outline Dimensions E-SF Ratings and Specifications E-SF /3.8 10/5 10/5 16/8 /13 7.5/3.8 15/ Thermal-magnetic7 (Red) Non Non Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : yes or available. : no or not available. 1 : DC rating available on request. 7 : Hydraulic-magnetic type for below 10 rating. Molded Case Circuit Breakers Frame Time/Current characteristic curves Tripping Time second minute hour Max. (60,75,) mbient Compensating Curves Percent current rating Percent current rating Min. 10 Min. (60,75,) Min.(15,20,30,0,50) Magnetic trip setting 0% 1600% Rated Current () Max.10 Percent Rated Current Magnetic trip current C () 150±50 2±75 300± 50± ± ±0 780± ±2 1300±300 Max. (15,20,30,0,50) mbient temperature ( C) Calibrated 0 temperature Calibrated temperature Magnetic trip setting 0% 2000% mbient temperature ( C) 8000 Combinations of Internally Mounted ccessoriesoptional Poles uxiliary switch larm switch Shunt trip 1 Under voltage trip 2 Toggle Left pole Right pole NOTE: 2-pole type breaker may incorporate only one combination of X (max.2c), L, SH, UV, X NOTE: 1 Shunt trip is provided with anti-burnout switch. NOTE: 2 The UV Controller is installed externally when provided with C UV. L into the left pole. -2

53 Outline dimensions (mm) SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Front-connected 2P Mounting hole 23.(10-50) 2(60-) M5 0.8 screw(10-50) M8 screw(60-) Preparation of conductor ON side 8(max.) 15(max.) ø5.5(10-50) ø9(60-) Drilling plan (front view) 2P C L SL SL 6.5 OFF side C.5 15(max.) ø5.5(10-50) ø9(60-) 8(max.) M 0.7 Mounting screw SL M 0.7 Tapped hole Rear-connected Insulated bushing ø15 2P M 0.7 Tapped hole Drilling plan (front view) 2P M 0.7 Tapped hole Panel cutout (front view) 2P ø17 SL Mounting plate Rated Current () C screw B B1 1 B C M6 M8 6.5 B M 0.7 Mounting screw SL ø ø15 for accessory wiring when necessary SL R Panel cutout dimensions shown give an allowance of 1.0mm around the handle escutcheon. Characteristics and Outline Dimensions -3

54 Type Number of poles Ratings Rated current, Calibrated at 5 C Rated insulation voltageu i V C Rated impulse withstand voltage U imp kv Utilization Category Rated breaking capacity, k IEC C 690V I cu /I cs (sym) 500V 0V 15V 380V 20V DC 0V 1V Rated short time withstand current, k Weight (' marked standard type) kg Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread extension bars Cable clamps Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug5B (PG) DIN rail mount Clip-in chassis mount ccessories (optional) Symbol Motor operator External operating Breaker-mounted handle Door-mounted (variable depth) Toggle extension Mechanical interlock Slide type Toggle holder Toggle lock Terminal cover For front-connected For rear-connected and plug-in For cable clamps Interpole barrier Terminal block for lead Door flange Standard specifications Overcurrent trip mechanism Trip button (color) Handle position indication (ON: Red, OFF: Green) Suitability for isolation CE marking Externally mounted 160 Characteristics and Outline Dimensions E160-SF Ratings and Specifications E160-SF /13 10/5 0.3 ' Thermal-magnetic (Red) Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : yes or available. : no or not available. 1 : DC rating available on request. Molded Case Circuit Breakers Frame Time/Current characteristic curves Tripping Time hour minute second Min , Rated Current () Max Percent Rated Current Magnetic trip current C () 600± ± ± ± ± ±120 0±200 0± ± mbient Compensating Curves Percent current rating ,80 50,1 20 Calibrated temperature mbient temperature ( C)

55 SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions (mm) E160-SF Front-connected 1P M5 0.8 screw (16-50) M8 screw (63-1) 1P With extension bars (optional) 28 Drilling plan (front view) M 0.7 Mounting screw M 0.7 Tapped hole Characteristics and Outline Dimensions -5

56 Type Number of poles Ratings Rated current, Calibrated at 0 C Externally mounted 160 Ratings and Specifications S160-SCF Rated insulation voltageu i V C 690 Rated impulse withstand voltage U imp kv Utilization Category Rated breaking capacity, k 8 IEC C 690V I cu /I cs (sym) 500V 0V 15V 380V 20V 7.5/ 15/7.5 /13 /13 35/18 DC 0V 1V 20/10 30/15 Rated short time withstand current, k Weight (' marked standard type) kg Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars ' With spread extension bars Cable clamps Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug5B (PG) DIN rail mount Clip-in chassis mount ccessories (optional) Symbol Motor operator External operating Breaker-mounted handle Door-mounted (variable depth) Toggle extension Mechanical interlock Slide type Toggle holder Toggle lock Terminal cover For front-connected For rear-connected and plug-in For cable clamps Interpole barrier Terminal block for lead Door flange Standard specifications Overcurrent trip mechanism Trip button (color) Handle position indication (ON: Red, OFF: Green) Suitability for isolation CE marking Thermal-magnetic (Red) S160-SF 3 Characteristics and Outline Dimensions Molded Case Circuit Breakers S160-SCF, S160-SF /3 10/7.5 /13 0/20 0/20 50/ /13 0/ ' Thermal-magnetic (Red) Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : yes or available. : no or not available. 1 : DC rating available on request. 3 : Line side interpole barriers are supplied as standard. (Front connection only)!1 : Provided with DIN rail adaptor. Frame Time/Current characteristic curves Tripping Time hour minute second Min Rated Current () Max Percent Rated Current Magnetic trip current C () 600± ± ± ± ±120 0±200 0± ± ± ± mbient Compensating Curves Percent current rating ,20 60, 50,1 160 Calibrated temperature mbient temperature ( C) 8000 Combinations of Internally Mounted ccessoriesoptional Poles uxiliary switch larm switch Shunt trip Under voltage trip Toggle Left pole Right pole -6

57 SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions (mm) S160-SCF, S160-SF Front-connected Interpole barrier (removable) 2P P Mounting hole Preparation of conductor 16.5(max.) max.t5 M5 0.8 screw (15-50) M8 screw (60-160) 50 2 ø9 6.5(max.) With extension bars (optional) 2P P 28 Drilling plan (front view) 2P P N M 0.7 Mounting screw ø8.3 ø M 0.7 Tapped hole Note: For the extension bars, Straight bars or Spread bars can be supplied. 2 poles is straight bars only. Rear-connected Detail of connecting part B C B D C Mounting plate (max. t3.2) F D E 2P P 2P Drilling plan (front view) P Panel cutout (front view) 2P P 37.5 R M 0.7 Mounting screw Studs are horizontal direction only Rated current () B C D E F ø20 M 0.7 Tapped hole Panel cutout dimensions shown give an allowance of 1.0mm around the handle escutcheon. Characteristics and Outline Dimensions -7

58 Type Number of poles Ratings Rated current, Calibrated at 0 C center pole omitted Rated insulation voltageu i V C Rated impulse withstand voltage U imp kv Utilization Category Rated breaking capacity, k IEC C 690V I cu /I cs (sym) 500V 0V 15V 380V 20V DC 0V 1V Rated short time withstand current, k Weight (' marked standard type) kg Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread extension bars Cable clamps Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug5B (PG) DIN rail mount Clip-in chassis mount ccessories (optional) Symbol Motor operator External operating Breaker-mounted handle Door-mounted (variable depth) Toggle extension Mechanical interlock Slide type Toggle holder Toggle lock Terminal cover For front-connected For rear-connected and plug-in For cable clamps Interpole barrier Terminal block for lead Door flange Standard specifications Overcurrent trip mechanism Trip button (color) Handle position indication (ON: Red, OFF: Green) Suitability for isolation CE marking Externally mounted 0 Ratings and Specifications E0-SF /7.5 15/12 /19 /19 35/27 15/12 / ' Thermal-magnetic (Red) S0-SF Characteristics and Outline Dimensions Molded Case Circuit Breakers E0-SF, S0-SF /2 /13 30/15 0/20 0/20 85/3 /13 0/ ' Thermal-magnetic (Red) Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : yes or available. : no or not available. 1 : DC rating available on request. 3 : Line side interpole barriers are supplied as standard. (Front connection only) Tripping Time Frame Time/Current characteristic curves hour minute second mbient Compensating Curves Percent current rating Min Max. Percent Rated Current Magnetic trip setting 880% 1320% Magnetic trip setting % 1560% Calibrated temperature mbient temperature ( C) 8000 Combinations of Internally Mounted ccessoriesoptional Poles uxiliary switch larm switch Shunt trip Under voltage trip Toggle Left pole Right pole -8

59 SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions (mm) E0-SF, S0-SF Front-connected Interpole barrier (removable) P Mounting hole 101 Preparation of conductor M8 screw ø9 With extension bars (optional) Interpole barrier Mounting hole (max.) P max.t7 (removable) Conductor Conductor overlap, max overlap, max (max.) Drilling plan (front view) P M 0.7 Mounting screw 7 ø ø M 0.7 Tapped hole Note: For the extension bars, Straight bars or Spread bars can be supplied. Rear-connected Drilling plan (front view) Panel cutout (front view) Detail of connecting part Mounting plate (max. t3.2) Conductor overlap, max 22 ø M Stud can be turned Mounting screw or P 7 ø2 P M 0.7 Tapped hole P R1 52 Panel cutout dimensions shown give an allowance of 1.0mm around the handle escutcheon. Characteristics and Outline Dimensions -9

60 Type Number of poles Ratings Rated current, Calibrated at 5 C Rated insulation voltageu i V C Rated impulse withstand voltage U imp kv Utilization Category Rated breaking capacity, k IEC C 690V I cu /I cs (sym) 500V 0V 15V 380V 20V DC 0V 1V Rated short time withstand current, k Weight (' marked standard type) kg Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread extension bars Cable clamps Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug5B (PG) DIN rail mount Clip-in chassis mount ccessories (optional) Symbol Motor operator External operating Breaker-mounted handle Door-mounted (variable depth) Toggle extension Mechanical interlock Slide type Toggle holder Toggle lock Terminal cover For front-connected For rear-connected and plug-in For cable clamps Interpole barrier Terminal block for lead Door flange Standard specifications Overcurrent trip mechanism Trip button (color) Handle position indication (ON: Red, OFF: Green) Suitability for isolation CE marking Externally mounted 160 Ratings and Specifications S160-SCJ / 15/7.5 /13 /13 35/18 20/10 30/ ' Thermal-magnetic (Red) S160-SJ /3 10/7.5 /13 0/20 0/20 50/ /13 0/ ' Characteristics and Outline Dimensions Molded Case Circuit Breakers S160-SCJ, S160-SJ Thermal-magnetic (Red) Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : yes or available. : no or not available. 1 : DC rating available on request. 3 : Line side interpole barriers are supplied as standard. (Front connection only)!1 : Provided with DIN rail adaptor. Frame Time/Current characteristic curves Tripping Time hour minute second Min Rated Current () Max Percent Rated Current Magnetic trip current C () 600± ±120 0±200 0± ± ± ± mbient Compensating Curves Percent current rating Calibrated temperature mbient temperature ( C) 8000 Combinations of Internally Mounted ccessoriesoptional Poles uxiliary switch larm switch Shunt trip Under voltage trip Toggle Left pole Right pole -10

61 SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions (mm) S160-SCJ, S160-SJ Front-connected 22 Interpole barrier (removable) P Mounting hole Preparation of conductor 16.5(max.) max.t5 M5 0.8 screw (-0) M8 screw (63-160) 50 2 ø9 6.5(max.) With extension bars (optional) P 28 Drilling plan (front view) P N M 0.7 Mounting screw ø ø M 0.7 Tapped hole Note: For the extension bars, Straight bars or Spread bars can be supplied. Rear-connected Detail of connecting part B B E P Drilling plan (front view) Panel cutout (front view) C D C Mounting plate (max. t3.2) F D P 37.5 P M 0.7 Mounting screw Studs are horizontal direction only Rated current () B C D E F ø20 M 0.7 Tapped hole Panel cutout dimensions shown give an allowance of 1.0mm or more around the handle escutcheon. Characteristics and Outline Dimensions -11

62 Type Number of poles Ratings Rated current, Calibrated at 5 C Rated insulation voltageu i V C Rated impulse withstand voltage U imp kv Utilization Category Rated breaking capacity, k IEC C 690V I cu /I cs (sym) 500V 0V 15V 380V 20V DC 0V 1V Rated short time withstand current, k Weight (' marked standard type) kg Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread extension bars Cable clamps Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug5B (PG) DIN rail mount Clip-in chassis mount ccessories (optional) Symbol Motor operator External operating Breaker-mounted handle Door-mounted (variable depth) Toggle extension Mechanical interlock Slide type Toggle holder Toggle lock Terminal cover For front-connected For rear-connected and plug-in For cable clamps Interpole barrier Terminal block for lead Door flange Standard specifications Overcurrent trip mechanism Trip button (color) Handle position indication (ON: Red, OFF: Green) Suitability for isolation CE marking Externally mounted 0 Ratings and Specifications E0-SJ 3 Characteristics and Outline Dimensions Molded Case Circuit Breakers E0-SJ, S0-SJ Combinations of Internally Mounted ccessoriesoptional /6 15/12 /19 /19 35/27 15/12 / ' Thermal-magnetic (Red) S0-SJ /2 10/7.5 30/15 0/20 0/20 85/3 /13 0/ ' Thermal-magnetic (Red) Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : yes or available. : no or not available. 1 : DC rating available on request. 3 : Line side interpole barriers are supplied as standard. (Front connection only) Frame Time/Current characteristic curves Tripping Time Tripping Time hour minute second hour minute second Min. Magnetic trip setting 00% 600% Max Percent Rated Current Magnetic trip setting % 1560% mbient Compensating Curves Percent current rating Min. Magnetic trip setting 00% 600% Max. Percent Rated Current 200,0 1,160 Magnetic trip setting 880% 1320% Calibrated temperature mbient temperature ( C) (-200) 8000 (0) 8000 Poles uxiliary switch larm switch Shunt trip Under voltage trip Toggle Left pole Right pole -12

63 SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions (mm) E0-SJ, S0-SJ Front-connected Interpole barrier (removable) P Mounting hole 101 Preparation of conductor M8 screw 2 With extension bars (optional) Interpole barrier Mounting hole P (max.) (removable) max.t7 Conductor Conductor overlap, max overlap, max ø9 11(max.) Drilling plan (front view) P M 0.7 Mounting screw 7 ø ø M 0.7 Tapped hole Note: For the extension bars, Straight bars or Spread bars can be supplied. Rear-connected Drilling plan (front view) Panel cutout (front view) Detail of connecting part Mounting plate (max. t3.2) Conductor overlap, max 22 M Stud can be turned Mounting screw or ø9 1 P 7 ø2 P M 0.7 Tapped hole 52.5 P Panel cutout dimensions shown give an allowance of 1.0mm around the handle escutcheon. Characteristics and Outline Dimensions -13

64 160 Ratings and Specifications Characteristics and Outline Dimensions Molded Case Circuit Breakers S160-SN Frame Type Number of poles Ratings Rated current, Rated insulation voltageu i V Rated operational voltage V C C DC Rated short circuit making capacity, k peak Rated short time withstand current, k Rated impulse withstand voltage U imp kv Performance Utilization category C 690V IEC DC 0V Upstream breaker Weight (' marked standard type) kg Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread extension bars Cable clamps Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug5B (PG) DIN rail mount Clip-in chassis mount ccessories (optional) Symbol Motor operator External operating Breaker-mounted handle Door-mounted (variable depth) Toggle extension Mechanical interlock Slide type Toggle holder Toggle lock Terminal cover For front-connected For rear-connected and plug-in For cable clamps Interpole barrier Terminal block for lead Door flange Standard specifications Trip button (color) Handle position indication (ON: Red, OFF: Green) Suitability for isolation CE marking Externally mounted S160-SN sec 8 C-23 DC-22 S160-SF ' e (Red) Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : yes or available. : no or not available. 3 : Line side interpole barriers are supplied as standard. (Front connection only)!1 : Provided with DIN rail : Required for overcurrent protection. Rated conditional short-circuit current [I cc ] will be the same as Rated short-circuit breaking capacity of upstream breaker. Combinations of Internally Mounted ccessoriesoptional Poles uxiliary switch larm switch Shunt trip Under voltage trip Toggle Left pole Right pole -1

65 SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions (mm) S160-SN Front-connected 22 Interpole barrier (removable) P Mounting hole Preparation of conductor M5 0.8 screw (-0) M8 screw (63-160) ø9 9(max.) With extension bars (optional) P 28 Drilling plan (front view) P N M 0.7 Mounting screw ø ø M 0.7 Tapped hole Note: For the extension bars, Straight bars or Spread bars can be supplied. Rear-connected Detail of connecting part B B E P Drilling plan (front view) Panel cutout (front view) C D C Mounting plate (max. t3.2) 5 D P 37.5 P B C D E M 0.7 Mounting screw Studs are horizontal direction only ø20 M 0.7 Tapped hole Panel cutout dimensions shown give an allowance of 1.0mm or more around the handle escutcheon. Characteristics and Outline Dimensions -15

66 0 Ratings and Specifications Characteristics and Outline Dimensions Molded Case Circuit Breakers S0-SN Frame Type Number of poles Ratings Rated current, Rated insulation voltageu i V Rated operational voltage V C C DC Rated short circuit making capacity, k peak Rated short time withstand current, k Rated impulse withstand voltage U imp kv Performance Utilization category C 690V IEC DC 0V Upstream breaker Weight (' marked standard type) kg Connections and Mountings Front-connected (FC) Terminal screws With straight extension bars With spread extension bars Cable clamps Rear-connected (RC) Bolt studs Flat bar studs Plug-in (PM) For switchboards Standard (PMC) High-performance (PMB) For distribution boards (PMC) Draw-out type (DR) TemPlug70 (PG) TemPlug5B (PG) DIN rail mount Clip-in chassis mount ccessories (optional) Symbol Motor operator External operating Breaker-mounted handle Door-mounted (variable depth) Toggle extension Mechanical interlock Slide type Toggle holder Toggle lock Terminal cover For front-connected For rear-connected and plug-in For cable clamps Interpole barrier Terminal block for lead Door flange Standard specifications Trip button (color) Handle position indication (ON: Red, OFF: Green) Suitability for isolation CE marking Externally mounted S0-SN sec 8 C-23 DC-22 S0-SF ' e (Red) Notes: ' : Standard. This configuration used unless otherwise specified. : Optional standard. Specify when ordering. : yes or available. : no or not available. 3 : Line side interpole barriers are supplied as standard. (Front connection : Required for overcurrent protection. Rated conditional short-circuit current [I cc ] will be the same as Rated short-circuit breaking capacity of upstream breaker. Combinations of Internally Mounted ccessoriesoptional Poles uxiliary switch larm switch Shunt trip Under voltage trip Toggle Left pole Right pole -16

67 SL : rrangement Standard Line : Handle Frame Centre Line : Handle Centre Line Outline dimensions (mm) S0-SN Front-connected Interpole barrier (removable) P Mounting hole 101 Preparation of conductor M8 screw 2 With extension bars (optional) Interpole barrier Mounting hole P (max.) (removable) max.t7 Conductor Conductor overlap, max overlap, max ø9 11(max.) Drilling plan (front view) P M 0.7 Mounting screw 7 ø ø M 0.7 Tapped hole Note: For the extension bars, Straight bars or Spread bars can be supplied. Rear-connected Drilling plan (front view) Panel cutout (front view) Detail of connecting part Mounting plate (max. t3.2) Conductor overlap, max 22 M Stud can be turned Mounting screw or ø9 1 P 7 ø2 P M 0.7 Tapped hole 52.5 P Panel cutout dimensions shown give an allowance of 1.0mm around the handle escutcheon. Characteristics and Outline Dimensions -17

68 TERSKI SKNDINVISK B (Sweden) TERSKI ELECTRIC (EUROPE) LTD. (United Kingdom) TERSKI ESPÑ, S..U. (Spain) TERSKI ITLI s.r.l. (Italy) TERSKI Global Network TERSKI ELECTRIC CO., LTD. (Head Quarters, Japan) TERSKI ELECTRIC (M) SDN. BHD. (Malaysia) TERSKI CIRCUIT BREKERS (S) PTE. LTD. (Singapore) TERSKI ELECTRIC CO., (FR EST) PTE. LTD. (Singapore) TERSKI ELECTRIC (SHNGHI) CO., LTD. (China) TERSKI ELECTRIC (CHIN) LTD. (China) TERSKI DO BRSIL LTD. (Brazil) Since 1971 when we established TERSKI ELECTRIC Europe, our first overseas subsidiary, in the UK, we have assembled a global network of 10 overseas subsidiaries and 58 agents to provide sales and technical supports to customers worldwide.! Safety Notice Carefully read instruction manual to ensure proper installation, connection, operation, handling and maintenance of the product. Head Office : Hannancho, benoku, Osaka, JPN Circuit Breaker Division : Kamihigashi, Hiranoku, Osaka, JPN Telephone : / Fax : int-sales@terasaki.co.jp SEP K Catalogue No. 10!6E Ratings and specifications are subject to change without notice. This document is printed with environmentally friendly soy ink.

Molded Case Circuit Breaker

Molded Case Circuit Breaker & The Ultimate Safety Breaker Molded Case Circuit Breaker www.terasaki.co.jp Catalogue No. 13!5E ! Safety Notice Carefully read instruction manual to ensure proper installation, connection, operation,

More information

18-I73E CAT REF.

18-I73E CAT REF. & www.terasaki.co.jp 1-I73E CAT REF. TABLE OF CONTENTS General 1-1 Introduction 1- General 1-3 Selection Chart 1- Ratings and Specifications -1 Air Circuit Breakers for DC350V-00V - Moulded Case Circuit

More information

15-I73E CAT REF.

15-I73E CAT REF. & www.terasaki.co.jp 5-I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers

More information

14-I73E CAT REF.

14-I73E CAT REF. & www.terasaki.co.jp -I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

12-I73Eb CAT REF.

12-I73Eb CAT REF. & www.terasaki.co.jp -I7Eb CAT REF. TABLE OF CONTENTS General - Outline Dimensions 5- Introduction - DC Air Circuit Breakers Outline Dimensions General - Selection Chart - AR6S, AR0S 5- AR5S, ARS 5- Ratings

More information

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual 11-M61E TABLE OF CONTENTS HANDLING & MAINTENANCE Storage 1 Transport 1 STANDARD ENVIRONMENT 1 INSTALLATION AND CONNECTION

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) Types: AR650S,AR663S,AR663H Notice Be sure to read this manual before installing, operating,

More information

Molded Case Circuit Breakers H series General information

Molded Case Circuit Breakers H series General information General information Description Models with high breaking capacities Line protection : 15 to 800A Motor protection : 16 to 5A Molded case color : Black Type number nomenclature Series H: H 5 BA / E Q M

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) Types: AR208S AR212S AR216S AR220S AR325S AR332S AR440S AR440SB AR212H AR216H AR220H AR316H

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B Overcurrent Protective Device) Types: AR650S,AR663S,AR663H Notice Be sure to read this manual before installing, operating,

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) Types: KA208S KA212S KA216S KA220S KA325S KA332S KA440S KA212H KA216H KA220H KA316H KA320H

More information

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

Low breaking capacity moulded case circuit breakers

Low breaking capacity moulded case circuit breakers New series EB2S of MCCBs has excellent performances with reduced dimensions and new modern design. Advantages of low breaking capacity MCCBs Unique accessory cover opens with only one screw. Practical

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR208S AR212S AR216S AR220S AR325S AR332S AR440S AR440SB AR212H AR216H

More information

MOULDED CASE CIRCUIT BREAKERS 16A TO 630A

MOULDED CASE CIRCUIT BREAKERS 16A TO 630A TEMBREAK 2 MOULDED CASE CIRCUIT BREAKERS 16A TO 630A 1. Welcome to TemBreak 2 2. Ratings and Specifications 3. Operating Characteristics 4. Application Data 5. Accessories 6. Installation 7. Dimensions*

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Air Circuit Breaker Instruction Manual

Air Circuit Breaker Instruction Manual Innovators in Protection Technology Air Circuit Breaker Instruction Manual AGR-31B Overcurrent Protection Device 06-M55EC INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-31B

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR650S, AR663S, AR663H Notice Be sure to read this manual before installing,

More information

INSTRUCTION MANUAL FOR AR-E AIR CIRCUIT BREAKERS (Fixed type and Type AGR-12B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AR-E AIR CIRCUIT BREAKERS (Fixed type and Type AGR-12B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AR-E AIR CIRCUIT BREAKERS (Fixed type and Type AGR-12B Overcurrent Protective Device) Types: AR206E AR208E AR210E AR212E AR216E Notice Be sure to read this manual before installing,

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

3VT Kompaktleistungsschalter bis 630A

3VT Kompaktleistungsschalter bis 630A Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Low voltage circuit breakers

Low voltage circuit breakers Comprehensive Catalogue 2006 Super Solution Low voltage circuit breakers A-3. Accessories TD & TS MCCB Index Electrical auxiliaries Undervoltage release, UVT Shunt release, SHT Auxiliary switch (AX),

More information

Air Circuit Breaker Instruction Manual

Air Circuit Breaker Instruction Manual Innovators in Protection Technology Air Circuit Breaker Instruction Manual AGR-21B/22B Protection Relays 06-M55EB INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-21B, 22B

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity

More information

Optional Accessories 47-83

Optional Accessories 47-83 Optional ccessories 47-83 Internally mounted accessories 48-1 Overview 48 onnection diagrams and terminal numbers 49 Ratings 0 ombinations 1 Externally mounted accessories 2-83 Overview 2-3 Motor operators

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

5. OVERCURRENT RELEASE (OCR)

5. OVERCURRENT RELEASE (OCR) 5. OVERCURRENT RELEASE (OCR) Options available for the type AR ACBs include a highly reliable, multi-functional overcurrent release (OCR) with a built-in 8- bit microprocessor. This OCR is supplied with

More information

3VT1 Molded Case Circuit Breakers up to 160 A

3VT1 Molded Case Circuit Breakers up to 160 A Siemens AG 4 VT Molded Case Circuit Breakers up to 6 A Catalog Technical Information VT Molded Case Circuit Breakers up to 6 A / General data / Circuit breakers Switch disconnectors Accessories and Components

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Overcurrent releases - description, specifications, characteristics specifications specifications description... BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits 7 Technical Data Dielectric strength Circuit Withstand voltage (at 50/60 Hz) Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control

More information

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key HSB Series Full Size Interlock Switch HSB features: Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

(Example) In case of DC24 to 48V, it is operating time for DC24V.

(Example) In case of DC24 to 48V, it is operating time for DC24V. 7 9 8 Closing coil (CC) The closing coil is a device to close the breaker by remote control. An interlock to prevent pumping is provided electrically. CC circuit diagram Rated voltage (Applicable voltage

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Innovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20E

Innovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20E Innovators in Protection Technology TemBreak Total Protection, Complete Control Catalogue No. 05 - I0E Terasaki (Europe) Ltd Terasaki Europe Ltd was established in 97 and is located near Glasgow, Scotland

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available with or without

More information

Magnetic Overcurrent Circuit Breaker

Magnetic Overcurrent Circuit Breaker Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

HS1E Series Full Size Solenoid Locking Switches

HS1E Series Full Size Solenoid Locking Switches HS1E Series Full Size Solenoid Locking Switches AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview HS1E features: Basic unit and solenoid unit in one

More information

Molded case circuit breakers

Molded case circuit breakers Molded case circuit breakers Metasol 30F to 250F Series Type Type and Pole Rated current, In Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Frame Size(F)

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB

Section Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB 1 Section Contents PAGES 1. Introduction 2-5 Salient features, internal & general appearance of Drawout ACB 2. Ratings & Specifications 6-9 Free air & enclosed thermal current ratings for AC & DC applications

More information

Innovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20EJ

Innovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20EJ Innovators in Protection Technology TemBreak Total Protection, Complete Control Catalogue No. 0 - IEJ Mission Statement. Terasaki aims to be the best supplier of circuit breakers and associated equipment

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :

More information

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Series HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Key features include: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

SENTRON 3VT Molded Case Circuit Breakers up to 1600 A

SENTRON 3VT Molded Case Circuit Breakers up to 1600 A Siemens AG 4 SENTRON VT Molded Case Circuit Breakers up to 6 A Catalog LV 6 4 VT Molded Case Circuit Breakers up to 6 A VT Molded Case Circuit Breakers up to 5 A The products and systems described in this

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block. PNE ISOTORS Craig & Derricott has a range of products designed specifically for control panel and switchboard construction. Most panels require a means of electrical isolation and the can offer variants

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Full Size Locking Switches Overview X Series E-Stops HSE features: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal screws

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

5. OVERCURRENT RELEASE (OCR)

5. OVERCURRENT RELEASE (OCR) 5. OVERCURRENT RELEASE (OCR) Options available for the type AR ACBs include a highly reliable, multi-functional overcurrent release (OCR) with a built-in 8- bit microprocessor. This OCR is supplied with

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS

More information

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information