7 Potentiometer Legend Plate Cat. No. 800H-W080
|
|
- Robyn McDonald
- 5 years ago
- Views:
Transcription
1 Bulletin T/H Legend Plates Plastic, / (H) H-W Jumbo Legend Plate H-WJ Blank/Custom Legend Plates Automotive Legend Plate H-WA Standard Jumbo Automotive Legend Plate Color Grey (Blank) H-W H-WJ H-WA Red (Blank) H-W H-WJ H-WA White (Blank) H-W H-WJ H-WA Yellow (Blank) H-W H-WJ H-WA Grey (with Custom Text) H-WE H-WJE H-WAE Red (with Custom Text) H-WE H-WJE H-WAE White (with Custom Text) H-WE H-WJE H-WAE Yellow (with Custom Text) H-WE H-WJE H-WAE Note: Include text with custom legends. Custom Text Guidelines Legend Size Number of Lines Maximum Number of Characters per Line Standard Line of Lines of Jumbo Lines Automotive Lines Potentiometer Legend Plate H-W Legend Graduated s Only SPEED Custom Legend with Graduated Potentiometer Legends H-W H-W H-WE H-W H-WA H-W Start/Stop Legend Plates Emergency Stop Legend Plates Grey Yellow (Large Size) Yellow IEC Ring Type Push-to-Stop Pull-to-Start H-W H-WA Blank H-WA H-W Custom H-WE H-WAE - Publication A-CAA-EN-P
2 Bulletin T/H s Plastic, / (H) Grey Legend Plate Grey White White Legend Plate Grey White AUTO OFF HAND H-W H-W LOWER H-W H-W AUTO MAN OFF H-W H-W MAN AUTO H-W H-W CLOSE H-W H-W MAN OFF AUTO H-W H-W CYCLE START H-W H-W MOTOR RUN H-W H-W CYCLE STOP (Red) H-W MOTOR STOP (Red) H-W DECREASE H-W H-W OFF H-W H-W DOWN H-W H-W OFF COOLANT ON H-W H-W EMERG. STOP (Red) H-W OFF LOC REMOTE H-W EMERGENCY STOP (Red) H-W OFF MAN AUTO H-W H-W FAST H-W H-W OFF ON H-W H-W FEED START H-W ON H-W H-W FEED STOP (Red) H-W OPEN H-W H-W FOR. REV. H-W H-W OPEN CLOSE H-W H-W FOR. OFF REV. H-W H-W OPEN OFF CLOSE H-W H-W FORWARD H-W H-W OUT H-W H-W FOURTH SPEED H-W POWER ON H-W H-W FULL SPEED H-W H-W PULL-TO-START H-W HAND AUTO H-W H-W PUSH-TO-STOP (Red) H-W HAND OFF AUTO H-W H-W RAISE H-W H-W HIGH H-W H-W RAISE LOWER H-W HIGH LOW H-W RAISE OFF LOWER H-W H-W HIGH LOW OFF H-W RESET H-W H-W HIGH OFF LOW H-W H-W REVERSE H-W H-W IN H-W H-W RIGHT H-W H-W INCH H-W H-W RUN H-W H-W INCREASE H-W RUN INCH H-W JOG H-W H-W RUN JOG H-W JOG FORWARD H-W H-W SAFE RUN H-W JOG REVERSE H-W H-W SECOND SPEED H-W H-W JOG RUN H-W H-W SLOW H-W H-W JOG SAFE RUN H-W SLOW FAST H-W H-W JOG STOP RUN H-W SLOW OFF FAST H-W H-W LEFT H-W H-W SPEED H-W H-W LEFT RIGHT H-W SPEED H-W LOC OFF REMOTE H-W H-W START H-W H-W LOW H-W H-W START JOG H-W H-W LOW HIGH H-W START JOG STOP H-W H-W LOW OFF HIGH H-W START RUN STOP H-W LOW SPEED H-W H-W START STOP H-W H-W These legend plates do not comply with E-Stop standards that specify a yellow background, such as IEC -- and NFPA. Potentiometer type with graduated markings. Publication A-CAA-EN-P -
3 Bulletin T/H s Plastic, / (H) Grey Legend Plate Grey White White Legend Plate Grey White UP H-W H-W STOP (Red) H-W UP DOWN H-W STOP RUN START H-W UP OFF DOWN H-W H-W STOP START H-W H-W O (Red) H-W SUMMER OFF WINTER H-W H-W O I H-W H-W SUMMER WINTER H-W H-W I H-W H-W TEST H-W H-W I O II H-W H-W THIRD SPEED H-W H-W Flip Lever Legend Plates (for use with Series D operators) Blank H-W LOW H-W RUN H-W Customer-Specified H-WE BAS H-WF EN MARCHE H-WF CLOSE H-W LOW SPEED H-W SECOND SPEED H-W FERMER H-WF VITESSE MIN H-WF VITESSE H-WF DOWN H-W LOWER H-W SLOW H-W DESCENDRE H-WF ABAISSER H-WF LENT H-WF FAST H-W OFF H-W START H-W RAPIDE H-WF ARRÊTER H-WF MARCHE H-WF FORWARD H-W ON H-W TEST H-W AVANT H-WF DÉMARRER H-WF ESSAI H-WF FULL SPEED H-W OPEN H-W THIRD SPEED H-W VITESSE MAX H-WF OUVRIR H-WF VITESSE H-WF HIGH H-W OUT H-W I H-W HAUT H-WF SORTIR H-WF O H-W IN H-W RAISE H-W LEFT H-W ENTRER H-WF ÉLEVER H-WF GAUCHE H-WF INCH H-W RESET H-W RIGHT H-W POUCE H-WF RÉARMER H-WF DROITE H-WF JOG H-W REVERSE H-W UP H-W À COUPS H-WF ARRIERE H-WF EN HAUT H-WF characters max. characters max. Blank Customer-Specified EMERG. STOP ARRÊT URGENT STOP ARRET O Red H-W H-WE H-W H-WF H-W H-WF H-W - Publication A-CAA-EN-P
4 Bulletin T/H Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Mounting Instructions for Push Buttons with Shallow Blocks, Mini Blocks, Logic Reed Blocks, Sealed Switch Blocks, and Time Delay Blocks (see footnotes for exceptions) Dia. Dia. Change to -/ in. (. mm) for transformer type pilot light, push-to-test pilot lights, illuminated selector switches, and all push-pull buttons. Note: Large legend plate requires minimum horizontal spacing of -/ in. (. mm). Vertical minimum spacing dimension changes for the following legend plates: jumbo -/ in. (. mm); large -/ in. (. mm); cluster pilot light and -, -, -way switches -/ in. (. mm). Panel Thickness Kits are shipped with three / in. (. mm) gaskets. Refer to table below for number of washers required for various panel thicknesses. / in. (. mm) ( Gauge) Sketch illustrates the minimum distance between centerlines when mounting Bulletin T/H controls either side-by-side, facing each other, or one above the other. When control units are mounted so that the contact block terminals face each other, the -/ in. (. mm) dimension must be used in order to get proper electrical clearance. When control units are mounted so that the contact block terminals do not face each other, the -/ in. (. mm) dimension can be used. Typical Panel Cut-Out / in. (. mm) ( Gauge) / in. (. mm) ( Gauge) / in. (. mm) Panel T washers washers washer Thicker Than / in. (. mm) Panel / in. (. mm) H washers washers washers washer Thicker Than / in. (. mm) Panel / in. (. mm) / in. (. mm) Mounting Instructions for mm Small Pilot Lights Type A Legend Plate Preferred Construction Alternate Construction Type B Legend Plate Vertical Ø Ø Horizontal T-N Device T-PS, PSD, PST, QS, QST and RST T-PSDT Dimensions Horizontal / (.) -/ (.) Vertical -/ (.) -/ (.) Publication A-CAA-EN-P -
5 Bulletin T/H Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Legend Plate Dimensions (Bul. T Only) Jumbo Legend Plate Large Legend Plate Large Size Push-Pull/Twist Legend Plate T-X For panel mounting only. Not for use with Allen-Bradley enclosures. Round T-X Cluster Pilot Light and -- Way Switch Silver Legend Plate T-X Legend Plate Dimensions (Bul. H Only) Jumbo Legend Plate Large Legend Plate -/ (.) / (.) Round (Flip Lever Operators) Legend Plate Dimensions (Bul. T mm Pilot Lights Only) Legend Plate for Small Pilot Light Type A Legend Legend Plate for Small Pilot Light Type B Legend T-N T-N - Publication A-CAA-EN-P
30 Mm 800F 15Y E112. Legend Plates. Trigger Action Emergency Stop Legend Plates (60 mm Round)
30 Mm Legend Plates Trigger Action Emergency Stop Legend Plates (60 mm Round) 800F 15Y E112 a a a (cont'd) Text Text Code Description Code Description Blank No text W112 NÆDSTOPP, EMERGENCY STOP E112 EMERGENCY
More information800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position.
2-Position Push-Pull and Push-Pull/Twist Release Devices, Non-Illuminated Note: A jumbo or large legend plate is recommended, if space allows. 2-Position Push-Pull Cat. No. 800T-F6D4 2-Position Metal Push-Pull
More informationSelector Push Button Cat. No. 800T-K2AAXX. a b c d e f g Right Left Right Left. d, e, f, g. Contact Blocks. No contacts on operator
NEMA Push Specifications 800T/H 30.5 mm Push s Selector Push Devices (Bul. 800T only) Selector Push Cat. No. 800T-K2AAXX 800T KD 2 G J D E a b c d e f g Right Left Right Left Blank C K KA KB KC KD KE a
More informationKnob Lever Operator Cat. No. 800T-H17A 800 T HA 2 A. Protection Rating Description T Metal, Type 4/13 Plastic, Type 4/4X/13
2-Position Selector Switch Devices, Non-Illuminated Standard Knob perator Cat. No. 800T-H2 Knob Lever perator Cat. No. 800T-H17 Standard Knob perator Cat. No. 800H-HR2 800 T H 2 a b c d e a Protection
More informationPilot Devices. Legend plates. Legend plates mm. Text caps. Fixed legend plates. Special legend plates 8.103
Pilot Devices Fixed legend plates Special legend plates Text caps.03 Pilot Devices Special legend plates 22mm Legend plate holders with inserts 47 30 Description Catalog No. List Price SFA 66 920 R20 $
More information800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position.
NEM Push utton Specifications 800T/H 30.5 mm Push uttons 2-Position Push-Pull and Push-Pull/Twist Release Devices, Non-Illuminated Note: jumbo or large legend plate is recommended, if space allows. 2-Position
More informationControl stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A
Characteristics Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600, CSA A600-Q600 Standard version : TH Ambient air
More informationPendant control stations
: pages 30075/3 to 30075/6 Characteristics Environment Conforming to standards IEC 947-5-1, EN 60 947-5-1, IEC 337-1, VDE 0660-200 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600,
More informationC & S 22 mm NON-ILLUMINATED PUSHBUTTONS METAL BEZEL
C & S 22 mm NON-ILLUMINATED PUSHBUTTONS METAL BEZEL OPERATING HEADS, - IP65 CONTROL UNITS WITH CHROMIUM PLATED METAL BEZEL PROJECTING PUSH BUTTON BOOTED PUSH BUTTON IP66 WITH TRANSPARENT BOOT IP66 MUSHROOM
More informationAllen-Bradley 800T-FXD16RA1
NEM Push utton Specifications 800T/H 30.5 mm Push uttons 2-Position Push-Pull and Push-Pull/Twist Release Devices, Illuminated Note: jumbo or large legend plate is recommended, if space allows. Illuminated
More informationXAL control stations for Harmony style 5 Ø 22 control and signalling units with double insulated bezel Complete stations (screw clamp connections)
pages /2 and / pages /4 and /5 Complete stations (screw clamp connections) References Start or function (light grey base RAL 705, dark grey lid RAL 7016 ) Description Type Contact type Marking Reference
More informationPush Buttons 800 E-Stops! Specifications 22.5mm
! Specifications 22.5mm Front of Panel (Operators) Mechanical Ratings Description (800EP/ES) (800EM/EB) Vibration (assembled to panel) 10 to 2000Hz, 1.52mm displacement (peak-to-peak) max./10g max. Shock
More informationBulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents
Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures
More information800 T P B H 16 R. Momentary Contact Push Button Devices, Illuminated. 8 Rockwell Automation Publication 800-TD009A-EN-P
Momentary Contact Push utton Devices, Illuminated Extended Head Without Guard Cat. No. 800T-P16R Extended Head without Guard Cat. No. 800H-PR16R 800 T P H 16 R a Protection Rating T Metal, Type 4/13 H
More informationA22/M22. Specifications. Specifications Common to All. Complete Assemblies
Complete Assemblies Specifications Common to All A22/M22 The Following Pages Provide Information Common To Each Model of The A22/M22 Pushbutton Switch H A22 H A22S/W H A22K H M22 Specifications J APPROVED
More information800T/H 30 mm Push Buttons. Time-tested Durability, Industry Proven A Legacy of Leadership
800T/H 30 mm Push Buttons Time-tested Durability, Industry Proven A Legacy of Leadership Imitated, But Never Duplicated The Allen-Bradley Bulletin 800T and 800H push button product lines are in a class
More informationPUSHBUTTON UNITS & INDICATOR LIGHTS CLASS 52 - WATERTIGHT / OILTIGHT - 30 MM HEAVY DUTY CUSTOM SELECTOR SWITCH DESIGNS
CLASS - WATERTIGHT / OILTIGHT - 30 MM HEAVY DUTY CUSTOM SELECTOR SWITCH DESIGNS Assembled Non-Illuminated Selector Switches: - Determine Contact Block and Location. - Select Block Suffix. Example: J =
More informationPush Button Units and Indicator Lights
3SB3, Inscriptions, 22 mm Insert labels Push Button Units and Indicator Lights Push buttons (clear) and illuminated push buttons with a flat button can be fitted with insert labels for identification purposes,
More information22MM IEC PILOT DEVICES
HUMAN MACHINE INTERFACE MM IEC PILOT DEVICES c3controls offers the best selection of illuminated and non-illuminated push buttons and selector switches on the market today. We also have a full line of
More informationContacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON
Pilot Devices Technical data UL General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions
More informationBulletin 800MR/800MB Push Buttons
Bulletin 800MR/800MB Contact Blocks Bulletin 800M contact blocks are available with quick connect type terminals and screw terminals with pressure plates (in two sizes). Each quick connect type termination
More informationContacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size
Technical data UL Pilot Devices General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions
More informationBulletin 800G Hazardous Location Push Buttons
Bulletin 800G Hazardous Location Push Buttons Bulletin 800G Hazardous Location Push Buttons Build a Catalog Number IP66, Type 4X Class I, Zone 1 and Zone 2 Class I/Division 2 Groups A, B, C, and D Assembled
More informationTime-Tested Durability, Industry Proven A Legacy of Leadership mm 800T/H. 6 /
Time-Tested Durability, Industry Proven A Legacy of Leadership 30.5 mm 800T/H 6 / 2011 IMITATED, BUT NEVER DUPLICATED The Allen-Bradley Bulletin 800T and 800H push button product lines are in a class by
More informatione.
e. e. e. e. e. e. e. e. e. e. Characteristics Control and signalling units Ø 220 Harmony XB7 Monolithic pushbuttons, switches and pilot lights 1 2 Environment Protective treatment Standard version TH Ambient
More informationEmergency stops Award winning design
Emergency stops Award winning design Emergency stops Choosing the right emergency stop device is vital in order to increase the safety for your personnel and equipment. ABB has a very wide range of emergency
More informationThe specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.
General data QR control component range For a mounting hole diameter of.3 mm to IEC 60947 50V/10A max. Water-jet proof IP65 collar shapes The lamps of the pushbuttons can also be replaced from the front
More informationPilot devices. General construction
Modular range Pilot Devices Pilot devices General construction Snap-on features reduce installation time Bezels: black plastic or chrome metal Contact block holder features rear mounting with quick-release
More informationABB 30mm Pilot Devices Versatility in Design
30mm Pilot Devices ABB 30mm Pilot Devices Versatility in Design The main advantage of using ABB pilot devices is versatility. Our products are ideally designed to be the perfect choice for both 22mm and
More informationClarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC.
SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC CONTROL UNITS SWITCH DISCONNECTORS & CAM SWITCHES TOP-TECHNIC TOP-TECHNIC EMERGENCY STOP MAIN SWITCHES MAIN SWITCHES TOP-TECHNIC TOP-TECHNIC CAM SWITCHES FOR
More informationHKH Series. HAZCON Controls for Harsh and Hazardous Environments
HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective
More informationDATA PD SV13.., SV14.. Levelling Valves. Product. Function. Technical Features. Range Overview
Commercial Vehicle Systems Product DATA Doc. No. Y075 (EN - Rev. 00) PD-500-000 Function On vehicles fitted with air suspension, the Levelling Valve ensures that the axle suspension air bags maintain a
More informationHazardous Factory Sealed Control Devices
Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot
More informationPilot Devices, Compact Range
Pilot Devices, Compact Range The competitive choice The compact range is a new competitive choice for OEM customers and Panel Builders with high requirements of cost ef cient, easy to use and reliable
More informationMotors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2
GRUNDFOS GROUNDWATER SERVICE MANUAL Motors 4-6-8-10" CONTENTS Grundfos Motor Specifications... Page 2 Electrical Requirements... Page 8 -Transformer Capacity Maximum Motor Cable Length... Page 10 Full
More informationContact blocks and lamp blocks with holder for front mounting Max. number of blocks Included in holder blocks Catalog No. Ref.
Pilot Devices Accessories Contact blocks and lamp blocks with holder for front mounting Max. number of blocks Included in holder blocks Catalog No. Ref. Code List Price For non-illuminated operators 3
More informationACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS
Z A H LO C ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS BASIC CATALOG NUMBERS HKHPBMMSS1 HKHPBMMTC1 HKHPBILLMM1 HKHPBMMMR1 HKHPBMMMB1 HKHPBMMMG1 HKHDBLPBMMGR1 HKHPBPMTMR1 HKHPBPMTMB1 HKHPBPMTMG1 HKHPBTMTMR1
More informationPush buttons at a glance
104P Push Buttons Push buttons at a glance Contents The inside story....................... 1 Hot buttons........................... 2 Non-illuminated push buttons........... 3 Illuminated push buttons...............
More informationControl and Load Switch Specifications Bulletin Number 194E, 194L
Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13
More informationOiltight Switches & Pilot Devices
Oiltight Emergency Stop Stations Part Numbers: Emergency Stop Stations Description Contacts Plastic Bezel Metal Bezel Ø 40mm Pushlock Turn Reset 1NO-1NC HW1X-BV411-R* HW4X-BV411-R* 2NC HW1X-BV402-R* HW4X-BV402-R*
More informationø22mm HW Series Control Units
TREICHL-ATM Electronic Auf der Bült 10-12 D 41189 Mönchengladbach Tel. 02166 958545 Fax 02166 958547 email: atm@treichl.de internet: mm HW Series Control Units HW Series Control Units (Selection Guide)
More informationNon-illuminated Push Buttons
Non-illuminated Push Buttons 3 Accessories for push buttons Lockout attachment Contact block kits Lens kits Wobblestick kit Push Button Cap Interchangeable, snap-in design Protective caps 9 colors: red,
More informationPneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves
Quic-Pics Catalogue Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves Contents: Product Line Overviews 2 Manually Operated Valves 5 Pushbuttons 6 Toggle Switch 8 Knob
More informationGeneral_technical_data Series
Indicator actuator 2 500 Hz: 5 g Pushbutton actuator Lens flat/level with front bezel: - Momentary max. 3 600/h - Maintain max. 1 800/h Lens flat/raised above front ring: - Momentary max. 3 600/h - Maintain
More informationSTAINLESS STEEL PANEL MOUNT
Z A H LO C STAINLESS STEEL PANEL MOUNT Optional Legend Plate Cover Screw Retaining Washer Panel Mount Bracket Explosion Protective LED Pilot Light Stainless Steel Washer Actuator Spacer Locknut Explosion
More informationControl & Signalling Devices 22.5 mm. RoHS. Compliant
Control & Signalling Devices 22.5 mm RoHS Compliant Contents Characteristics General Characteristics Products Push Buttons, Selector Switches, Latching Mushroom Head Push Buttons, Pilot Lights & Illuminated
More informationRAFIX 22 QR. General data. Content
QR General data QR control component range For a mounting hole diameter of.3 mm to IEC 60947 50V/10A max. Water-jet proof IP65 collar shapes The lamps of the pushbuttons can also be replaced from the front
More informationEBMC Combination Line Starters and Enclosures
EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,
More informationPilot devices. General construction
Modular range 30mm Modular Range, 30mm Pilot devices General construction Snap-on features reduce installation time Bezels: black plastic or chrome metal Contact block holder features rear mounting with
More informationAutomation Products. Pilot devices, 22 mm The whole range
Automation Products Pilot devices, 22 mm The whole range News in this catalog! Customer specific marking online! Extended range of emergency stops! Extended range of machine stops both in Modular range
More informationContact block holder $ CBK-H5 CBK-AB Discount schedule CC. ABB Inc
Pilot Devices Components Contact blocks & holders Operator mounted contacts All CBK contact blocks, lamp modules and transformers can be used with CBK mm and CBG 30mm operators. Contact blocks are color
More informationPreferred Cutout, Disconnect Enclosure, Type 12
763.422.2600 Spec-00245 J763.422.2211 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Preferred Cutout, Enclosure, Type 12 INDUSTRY
More information09. Location of the electric components
09. Location of the electric components 9.1 Circuit marking and control panel «Swing» Pedal (AS211) 20 C CL Chauffage/ Climatisation Double travelling pedal Boom/intermediate boom control foot pedal Read
More informationS-2300 Pneumatic Selector Switch
S-2300 Pneumatic Selector Switch Pneumatic Control Manual 717.1 Selector Switches Section Product Bulletin S-2300 Issue Date 0290 The S-2300 Pneumatic Selector Switch is designed for manual switching of
More informationDivision 2 Contender Series Factory Sealed Control Stations
NEMA 3, 3R, 4, 4X, 12 IP66 Applications For use in washdown areas and other damp, wet and highly corrosive areas. Push buttons and selector switches are used in conjunction with contactors or magnetic
More informationPioneer 321 MSR. 2/14 Antwerpsesteenweg Gent - Oostakker T +32 (0) F +32 (0)
GB Instruction manual 2/14 www.welda.be F +32 (0)9 355 92 01 0 1 INTRODUCTION... 4 2 FRONT PANEL... 4 3 REAR PANEL... 5 4 INSTALLATION... 6 4.1 UNIT ASSEMBLY... 6 4.2 CONNECTIONS TO THE ELECTRICAL MAINS
More informationRotary Cam Switches. Rotary Cam Switches
Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit
More informationWall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12
763.422.2600 SPEC-00245 L763.422.2211 DISCONNECT WALL-MOUNT PREFERRED-CUTOUT DISCONNECTS PREFERRED CUTOUT, DISCONNECTS, TYPE 12 Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type
More informationABCS GRP Control Stations
ABCS GRP Control Stations Application Industrial and Hazardous areas IP65/66 Protection Degree IP66 (IP65 when fitted with an ammeter) Certification ATEX & IECEx Ex e II T4 or Ex ed IIC T4 Material Glass
More informationStyle Contact Type No. Button Color Code ø40mm Mushroom 1NC YW1B-V4E01R YW1B-V4E21R. Gasket ø40 YW1L-V4E11Q0R 2NC YW1L-V4E02Q➂R 6 (12V AC/DC)
Pushlock Pull/Turn eset Style Contact Type No. Button Color Code ø40mm Mushroom NC YWB-V4E0 2NC 3NC NO-NC NO-2NC 2NO-NC YWB-V4E02 YWB-V4E03 YWB-V4E YWB-V4E2 YWB-V4E2 ed only Dimensions Panel Thickness
More informationAutomatic Control System PS Pneumatic Training System. Features
Pneumatic Training System It is well known that Factory utomation is an indispensable measure to reduce labor cost, improve production efficiency and achieve higher product quality, which is widely adopted
More informationPlastic enclosures compact Of polycarbonate. Degree of protection: IP 66, 67, 69K UL type1, 3R, 4, 4X, 12, 13
Pilot devices, 22 mm Assembled stations and enclosures Assembled stations There are assembled stations of two types: In plastic enclosures and in metallic enclosures Both types of enclosures are available
More informationOiltight Switches & Pilot Devices
Oiltight Switches & Pilot Devices HW Series 22mm IEC Style Global Pushbuttons Circuit Breakers Terminal Blocks Timers Relays & Sockets Display Lights Switches & Pilot Lights Key features include: Locking
More informationPUSHBUTTONS SELECTOR SWITCHES CONTROL & INDICATING DEVICES. Top Quality Engineered for Maximum Performance
SELECTOR SWITCHES CONTROL & INDICATING DEVICES Heavy Duty Oil Tight Dust Tight Hose Test Water Tight One Contact Block System For Both Miniature Or Full Size Buttons Versatile Modular Snap-Lock Together
More informationPilot devices, 22 mm. Catalogue. 1SFC151001C0201, Edition 2, January 2006 Superseedes Catalogue 1SFC15100C0201 of December SFC151169F0001
Catalogue Pilot devices, 22 mm 1SFC151001C0201, Edition 2, January 2006 Superseedes Catalogue 1SFC15100C0201 of December 2004 1SFC151169F0001 ABB A sure hit in Pilot Devices Part of comprehensive ABB program
More informationOPERATOR ADAPTER A21ABA
OPERATOR ADAPTER A21ABA Installation Instructions for Allen Bradley Bulletin 1494F Disconnect Switches And Bulletin 1494D Circuit Breaker Operating Mechanisms (For parts list, see page 2) For floor mounted
More informationPump Panel Specifications
Technical Data Pump Panel Specifications Bulletin Numbers 13 and 133 Topic Page Specifications Electrical Ratings (Bulletins 13, 13X, 133, 133X) Mechanical Ratings (Bulletins 13, 13X, 133, 133X) 3 Construction
More informationControl & Indicating Devices
Control & Indicating Devices 22.5mm Push Buttons, Selector Switches & Pilot Lights Push Buttons Page 7.2 Emergency Push Buttons Page 7. Pilot Lights Page 7. Selector Switches Page Accessories Page 7.6
More informationContents. Limit Switches. Quick Selection Guide... page 6 2. Technical Definitions and Terminology... page 6 6
Contents.............. page 6 2 Technical Definitions and Terminology......................... page 6 6 Bulletin 801 General Purpose....... page 6 7 Bulletin 802A International Style Position Switches..................
More informationA. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:
SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification
More informationPlug and Play Kit Installation and Wiring (Non-Combo and Combo)
General Information This publication is to be used for Eaton Plug and Play enclosures designed starters that accept the M22 series 22mm cover control devices. To install the cover control kit (Follow the
More informationAn Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches
An Investment in Plant Floor Safety 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches Notes 2 802C Cable Pull Safety Switches Safety and Application Safety
More informationUL Enclosed Disconnect Switches (Fused and Non-Fused)
Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66
More informationContact Type Operator Position Type 4/13 Type 4/4X/13. Push Pull 40 mm
30 Mm Emergency Stop Devices 2-Position Push-Pull and Release Devices, Non-Illuminated Note: A jumbo or large legend plate is recommended, if space allows. 2-Position Push-Pull Cat. No. 800T-F6D4 2-Position
More informationGRAND UNION CANAL UXBRIDGE WEST LONDON UB8 2GH. Accommodation schedule. Block B
Block B B 0.1 Ground 2 81.64 878 1,550 B 0.2 Ground 2 65.38 703 1,450 B 0.3 Ground 2 75.23 809 1,500 B 0.4 Ground 1 51.55 554 1,250 B 0.5 Ground 1 55.34 595 1,275 B 0.6 Ground 1 52.9 569 1,250 B 0.7 Ground
More informationRocker Switches & Twin R13. Miniature rocker switch. Ultra thin rocker switch. Ratings up to 10A, 250Vac. High inrush tolerance
Rocker Switches Ultra thin rocker switch Ratings up to 15A, 250Vac Single and twin gang single: 17.4 x 6.8mm twin: 17.4 x 13.4mm Miniature rocker switch Ratings up to 15A, 250Vac High in-rush tolerance
More informationPITNEY BOWES FLEXIBLE INK JET TRANSPORT 36 FIT BASE: FIT-36. Parts Manual. (BOM: FIT36rev1.0) FIT-36parts_rev0 1
FLEXIBLE INK JET TRANSPORT 36 FIT BASE: FIT-36 Parts Manual (BOM: FIT36rev1.0) FIT-36parts_rev0 1 VERSION HISTORY The table below summarizes the history of this document as it is published onto the company
More informationBulletin 800F 22.5 Mm Push Buttons
Bulletin 800F 22.5 Mm Push Buttons Miscellaneous Description Type Pkg. 800F-AHA1 30.5 mm to 22.5 mm Hole Size Adapter This adapter allows a 22.5 mm push button operator to be installed in a panel with
More informationSection 9. Control Catalog
Heavy-Duty 22.5 mm Watertight/Oiltight Pilot Lights Standard Selection Process Select operator + Select power supply + Select nameplate, if required, = Complete Unit below from page 9-92 & 9-93 from pages
More informationList. Price D7-1MPB13 - D7-1MPB14 - D7-1MPB16 - D7-1YPB13- D7-1YPB14- D7-1YPB16- Accessories. Component
Pushbutton Stations Series D7 eavy Duty/Oil Tight Emergency Stop Pushbutton Stations ➊➋ Pushbutton Station List Dimensions Length Width Depth Type 4/13 (IP66) - Oil & Dust Tight Gray aluminium 30mm twist-to-reset
More informationPilot devices, 22 mm. Short Form Catalogue. Revised Januari 31, 2005
Short Form Catalogue Pilot devices, 22 mm, edition 2 December 2004 Superseedes Catalogue, December 2003 Revised Januari 31, 2005 1SFC151111C0201 ABB A sure hit in pilot devices Part of comprehensive ABB
More informationEnclosed Starter Selection Guide. Featuring Snap-together Wiring Technology
Enclosed Starter Selection Guide Featuring Snap-together Wiring Technology Enclosed Starter Wiring Made Easy How It Works Component wiring is color-coded by function. The wiring sleeve cover corresponds
More informationMotor-drive mechanisms, type BUL Spare parts list
1ZSC000562-ADA EN, REV. A Motor-drive mechanisms, type BUL Spare parts list This spare parts list has been compiled to help you with procurement of spares. To obtain trouble-free deliveries you should
More informationCENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies
Selection Checklist CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Use this checklist to help you configure your CENTERLINE 2500 Motor Control Center. You can type in the fields
More informationIEC Starter Approximate Dimensions
Technical Data IEC Starter Approximate Dimensions Bulletin Numbers 103H/107H/140M, 103-C/107/C, 105, 109, 106, 112, 113, 190E/191E, 190S/191S, 103S/107S, 103T/107T Topic Page Enclosed Starters and Motor
More informationMotor-drive mechanism, type BUL. Technical guide
Motor-drive mechanism, type BUL Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required
More informationSEQUESTR. External Disconnect Enclosure. Rev. A 2014 Pentair Equipment Protection PH hoffmanonline.com P/N
SEQUESTR External Disconnect Enclosure Rev. A 2014 Pentair Equipment Protection PH 763 422 2211 hoffmanonline.com P/N 89114180 89114234 SEQUESTER Instruction Table of Contents SEQUESTR Hardware...3 SEQUESTR
More informationSEQUESTR. External Disconnect Enclosure. Rev. C 2013 Pentair Equipment Protection PH hoffmanonline.com P/N
SEQUESTR External Disconnect Enclosure Rev. C 2013 Pentair Equipment Protection PH 763 422 2211 hoffmanonline.com P/N 87924206 87924207 SEQUESTR Instruction Table of Contents Hardware Included................................................................
More information150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz
Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings
More information1326AS Series 460V, Low Inertia, Brushless Servo s Product Data This publication provides product information for the 0.49 to 49.3 N-m (4.33 to 436 lb-in.) 1326AS Series 460V, Low Inertia, Brushless Servo
More informationOiltight Switches & Pilot Devices
mm - Series Transfomer Contact Assemblies For use with Illuminated Pushbuttons. Style Contacts Part Number 12V AC with LED 24V AC with LED 48V AC with LED 12V AC with Incandescent 24V AC with Incandescent
More informationENGLISH NO Fan Starter INSTRUCTION MANUAL. Fan Starter 4. 4 kw 400 V 3~(+N) 50 Hz ART. NO
ENGLISH NO. 148 317 01 2000-03-09 Fan Starter INSTRUCTION MANUAL Fan Starter 4 4 kw 400 V 3~(+N) 50 Hz ART. NO. 512337 List of contents Page CE, Declaration of conformity 3 Safety 4 Technical data 4 Accessories
More informationTable 1 of Required lamps and reflectors on commercial motor vehicles
Table 1 of 393.11 Required lamps and reflectors on commercial motor vehicles Item on the vehicle Quantity Color Location Position Height above the road surface in millimeters (mm) (with English units in
More informationPushbuttons B3. Options and ordering codes. Exploded view. BS 3. Green
Pushbuttons 3 IP65 protection Opaque or illuminated Metal or lack bezels Snap-on contact blocks Colour coded contacts Pushbutton stations International approvals including UL and CS Options and ordering
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:
More informationQuality touch! Pushbuttons and selector switches. Ø22mm QUICK AND EASY ACTUATOR INSTALLATION. Click! Click!
Pushbuttons and selector switches Ø22mm Quality touch! QUICK AND EASY ACTUATOR INSTALLATION Click! Click! - Actuator fixing on the mounting surface, through a Ø22mm drilled hole, is obtained using its
More informationGHG43 Series Control Stations
GHG43 Series Control Stations Nonmetallic or 316L Stainless Steel UL/cUL listed Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, (A) Ex de IIB + H2 T6 Cl. II, Div. 1, Groups E, F, G (cul) PTB ATEX
More informationPressure Controls Product Overview
Bulletin Product Overview NEMA Bulletin Style A (Internal Bellows) Description Style C (External Bellows) Air Compressors Compressed Air Monitor Systems Liquid Level Control Typical Applications Vacuum
More informationFlex Work Station Delivery Units Installation Guide
Flex Work Station Delivery Units Installation Guide Special Tools Level 1/4" Deep Well Socket 3/8" Masonary Bit 9/32" Wood Bit Hammer Drill Remove any packaging from the skid and the floor or wall mount
More informationSeries D7 Pilot Devices
Series General Description... 2 Pushbuttons Non-Illuminated... 4 Illuminated... 12 Emergency Stop Operators Non-Illuminated... 20 Three Position... 22 Twist-to-Release... 24 Keyed... 26 Illuminated...
More information