Plug and Play Kit Installation and Wiring (Non-Combo and Combo)

Size: px
Start display at page:

Download "Plug and Play Kit Installation and Wiring (Non-Combo and Combo)"

Transcription

1 General Information This publication is to be used for Eaton Plug and Play enclosures designed starters that accept the M22 series 22mm cover control devices. To install the cover control kit (Follow the steps below) Wiring Diagrams: FVNR NEMA and IEC starters/contactor Diagram #1 Step 1: for the Non-Combo unit NEMA type 1, remove the rectangular blank cover by pushing on the blank cover Nylon Fastener from the inside. This step is not required for the other Plug and Play NEMA type constructions. PUSH OUT FROM THE INSDE TO REMOVE THE COVER, EEMAC TYPE 1 ONLY Diagram #2 Step 2: Locate the mounting holes on the enclosure base to install the cover control kit and transformer or separate supply kits. The kits come with installation instructions and the hardware. CAUTION: READ AND FOLLOW INSTRUCTIONS PRIOR TO WIRING OR CONNECTING POWER. THIS PRODUCT CAN BE FACTORY OR FIELD CONFIGURED FOR MULTIPLE CONTROL MODES OR CONTROL VOLTAGES. CHECK THE COVER CONTROLS AND TRANSFORMER OR THE SEPARATE SUPPLY KITS FOR PROPER VOLTAGE BEFORE APPLYING POWER.

2 Typical Wiring diagrams: Enclosed starter/contactor assemblies supplied from factory are pre-wired as per figure A and B. Wiring Instructions: Figure A Figure B 1 REMOTE START CONTACT BETWEEN TERMINAL 1 AND 2 IS SUPPLIED BY THE CUSTOMER FOR THE HAND/OFF/AUTO KITS IN THE AUTO POSSITION. 2 ADDING A JUMPER BETWEEN TERMINAL 2 AND 3 IS REQUIRED FOR START/STOP PUSH BUTTON KITS AND IS SUPPLIED LOOSE. 3 A TERMINAL BLOCK JUMPER IS REQUIRED BETWEEN 4 AND 5 FOR TRANSFORMER KITS SECONDARY GROUNDING AND IS SUPPLIED WITH THE TRANSFORMER KITS. Various sub-assemblies are required to complete an assembly and are available in kit form for ease of installation by customers. These kits require minimal knowledge about the internal wire connections or installation tools. The following pages show the available kits. 1. Auxiliary contacts and the overload are not supplied in kit form but are available from your local distributors.

3 FVNR Cover Control Connections (Quick connect into the 5 pin connector) STOP-START (OFF-ON) Pushbutton (FIG. 1) STOP-START (OFF-ON) Selector Switch + Red (RUN) and Green (STOP) light (24Vac or 120Vac) (FIG. 5) STOP-START (OFF-ON) Pushbutton + Red (RUN) light (24Vac or 120Vac) (FIG. 2) HAND-OFF-AUTO (TEST-OFF-AUTO) Selector Switch (FIG. 6) STOP-START (OFF-ON) Selector switch (FIG. 3) HAND-OFF-AUTO (TEST-OFF-AUTO) Selector Switch + Red(RUN) light (24Vac or 120Vac) (FIG. 7) STOP-START (OFF-ON) Selector Switch + Red (RUN) light (24Vac or 120Vac) (FIG. 4) HAND-OFF-AUTO (TEST-OFF-AUTO) Selector Switch + Red (RUN) + Green (STOP) lights (24Vac or 120Vac) (FIG. 8)

4 FVNR Remote, CPT, No Cover Control and Separate Supply Connections (Quick connect into the 4 and 5 pin connector or to the Terminal Block) START/STOP Push Button Remote Kit (FIG. 9) C No Cover Control kit (FIG. 12) Seperate Supply 120Vac or 20Vac Control Kits (FIG. 14) START/STOP Selector Switch Remote Kit (FIG. 10) CPT Control Transformer Kits (FIG. 13) HOA Selector Switch Remote Kit (FIG. 11) Separate Supply 120Vac or 20Vac Control Kits (FIG. 14) Legends * Remote control device Wiring by others Terminal point connection in the plug and play unit X-CON For quick connectors, 2-CON, 4-CON and 5-CON for 2, 4 and 5 pin connectors respectively. Notes: 1. Normally Close (NC) auxiliary contact for OFF green light is included with the cover control kit (order separately). *For auxiliary contact catalog #, refer to the table on the enclosure cover label. 2. For assemblies without overload relay connect the 2 pin connector to the base assembly and marrett the wires 95 and 96 together.

5 Internal Accessories and Terminal Customer Connections Internal Customer Wiring Modification When Adding an Overload Note 1) for frame B move the A2 and 14NO wires to the A2 and 14NO on the overload Note 2) for frame C move the 14NO wires to the 14NO on the overload Field Modification Adding Auxiliary Contact Note 3) For frame B, C and D connect wires 95 and 96 to the NC contact of the overload Internal Field Wiring Modification for Lighting Application For frame B and C Mounted on top For frame D mounted on the left hand side MARRETT THE 2 WIRES, 95 AND 96 FOR LIGHTING AND RESISTIVE APPLICATION

6 Application specific ratings for the Plug and Play Termination Torque specifications for the Plug and Play

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters Motors Automation Energy Transmission & Distribution Coatings GPH2 Combination Soft Starters GPH2 Combination Soft Starter 5to 350 HP The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

3.1. NEMA Manual Starters.   Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters... Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp

More information

SECTION MOTORS & MOTOR CONTROLLERS

SECTION MOTORS & MOTOR CONTROLLERS SECTION 15170 MOTORS & MOTOR CONTROLLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Electric motors. B. Motor controllers for Packaged equipment. 1.02 SUBMITTALS A. Wiring diagrams with electrical characteristics

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA) 804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

GPH2 Combination Soft Starters

GPH2 Combination Soft Starters Combination Soft Starters The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general purpose AC motor soft starter package. It is designed for simple and quick installation and start-up, requiring

More information

Quick selector reference guide. Motor Control Center Aftermarket Buckets

Quick selector reference guide. Motor Control Center Aftermarket Buckets Quick selector reference guide Motor Control Center Aftermarket Buckets 2 EATON WWW.EATON.COM/MCCAFTERMARKET Table of contents Series 2100 MCC bucket Motor Control Center (MCC) Aftermarket Buckets Overview

More information

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes AE Threaded Combination and Non-Combination Full Motor Starters Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Class I, Division and, Groups C, D Class II, Division

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

Operation and Protection of Motors up to 600Hp at 460Vac (800A)

Operation and Protection of Motors up to 600Hp at 460Vac (800A) Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components

More information

Motors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11

Motors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11 Motors Automation Energy Transmission & istribution Coatings EP11 Enclosed rive Panel USA EP11 EP11 Enclosed rive Panel The Enclosed rive Panel is an industrial general purpose AC motor control and protection

More information

Softstarters. Softstarters Power electronic brakes Type PEB

Softstarters. Softstarters Power electronic brakes Type PEB Softstarters Power electronic brakes Softstarters Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB)

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

NEMA Vacuum Break Contactors and Starters

NEMA Vacuum Break Contactors and Starters NEMA Vacuum Break Contactors and Starters NEMA Vacuum Break Starter.1 Product Description....................................... Application Description.................................... Operation...............................................

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 6A 200A 30A 200A Fusible Disconnect SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings

More information

NMC Combination Line Starters and Enclosures

NMC Combination Line Starters and Enclosures NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line

More information

GPH2. Soft Starters. Applications. Standard Features. Centrifugal Pumps Screw Compressors Centrifugal Fans Wood Chipper Veneer Lathe Saw Conveyor

GPH2. Soft Starters. Applications. Standard Features. Centrifugal Pumps Screw Compressors Centrifugal Fans Wood Chipper Veneer Lathe Saw Conveyor The Combination Soft is a NEMA 4/12 Enclosed industrial general purpose AC motor soft starter package. It is designed for simple and quick installation and start-up, requiring only input power and output

More information

Standard Materials Bodies and covers: copper-free aluminum.

Standard Materials Bodies and covers: copper-free aluminum. -26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and

More information

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic

More information

Programmable Logic Controller. Mat Nor Mohamad

Programmable Logic Controller. Mat Nor Mohamad Programmable Logic Controller Mat Nor Mohamad Relays Electromagnetic Control Relays The PLC's original purpose was the replacement of electromagnetic relays with a solid-state switching system that could

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. usa.siemens.com/controls

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed

More information

BAC Custom Engineered Controls

BAC Custom Engineered Controls BAC Custom Engineered Controls Product Detail Product Introduction......................................... K2 BAC Custom Engineered Controls Benefits....................................................

More information

IEC Utilization Categories (Explanation)

IEC Utilization Categories (Explanation) IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC

More information

EBMC Combination Line Starters and Enclosures

EBMC Combination Line Starters and Enclosures EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,

More information

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum .1 Catalog Number Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor

More information

Type E/F Simplex & Duplex Pump Controllers

Type E/F Simplex & Duplex Pump Controllers Type E/ Simplex & Duplex Pump Controllers Simplex Pump Controllers A single KTA7 motor controller plus matching CA7 contactor can be combined in an enclosure as a Simplex Combination Controller for pumping

More information

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9. SED2 with Conventional Bypass Options Important Note: VD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies

More information

Operation and Protection of Motors up to 600Hp at 460Vac (800A)

Operation and Protection of Motors up to 600Hp at 460Vac (800A) Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components

More information

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy.

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Fast. Easy. Reliable Controls Express A wide selection of enclosed NEMA controls now available with faster shipping as a standard. usa.siemens.com/controls-express Table of Contents Starters at the speed

More information

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers Move to modern enclosed disconnect switch technology Enclosed disconnect switches eot Manual motor controllers The next generation of enclosed disconnect switches... Cutting edge design and technology

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

HVW701 HVAC Drive with By-Pass

HVW701 HVAC Drive with By-Pass s Automation Energy Transmission & Distribution Coatings HVW701 HVAC with By-Pass Designed Especially for HVAC Systems US.HVW701.By-Pass.07/2017 www.weg.net WEG HVAC-R Products WEG, a leading supplier

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls

More information

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable. Controls Express A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable. usa.siemens.com/controls-express Starters at the Speed You Need Siemens

More information

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver. Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems

More information

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175. SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary

More information

Power electronic brakes

Power electronic brakes Power electronic brakes Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB) Series features full-wave

More information

CM Lodestar Electric Chain Hoist Electrical Parts List

CM Lodestar Electric Chain Hoist Electrical Parts List CM Lodestar Electric Chain Hoist Electrical Parts List MODELS Key No. Part Name No. Req'd A, A-2, AA, AA-2, B, B-2 C, C-2, E, E-2, F, F- 2, H & H-2 J, J-2, JJ, JJ-2, L, L-2, LL, LL-2, R, R- 2, RR, RR-2,

More information

Catalog Number Identification with Elements Explained

Catalog Number Identification with Elements Explained Installation Manual 920 Remote Control Switches 30 through 225 ampere sizes This Installation! Manual is for green nameplate ASCO 920s only. For black nameplate ASCO 920s refer to Owners Manual 2D4920

More information

Instrument Enclosure Assemblies

Instrument Enclosure Assemblies Instrument Enclosure Assemblies Standard instrument enclosure Instrument enclosures offer a simple solution for the customer who doesn t have the time to install Signet meters into panels. Whether it s

More information

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the

More information

SIEMENS. Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide E87010-A0151-T003-A1-49EC. August, 2012

SIEMENS. Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide E87010-A0151-T003-A1-49EC. August, 2012 SIEMENS August, 12 Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide Hazardous voltage. Will cause death, serious injury, or property damage. Always de-energize and ground the

More information

Softstarters Type PSR. Softstarters

Softstarters Type PSR. Softstarters Type PSR Type PSR Type PSR General information Designed for motor currents from 3 to 45 A, PSR complement the existing advanced PST for 30-1050 A and the flexible PSS for 30-1050 A. The PSR Softstarter

More information

O-3. Compliances UL Classified UL 508, 698, 1203 NEMA 4, 4X, 7CD, 9EFG For CSA approvals, please consult factory.

O-3. Compliances UL Classified UL 508, 698, 1203 NEMA 4, 4X, 7CD, 9EFG For CSA approvals, please consult factory. Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. -3 Applications AE series threaded type combination

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker

More information

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection Reduced voltage starters Open & enclosed Reduced voltage starters Description Compact, space saving design 8 starter frame sizes, A16 to A750 Maximum U.L. horsepower ratings Mechanically interlocking as

More information

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter Operation, and Maintenance of the Instruction Bulletin Read and understand these instructions before attempting any installation, operation, or maintenance of the. This equipment shall be installed and

More information

Multiple vacuum pumps and associated equipment ASME air receiver NEMA 12 multiplex control panel

Multiple vacuum pumps and associated equipment ASME air receiver NEMA 12 multiplex control panel GENERAL The Powerex laboratory vacuum system is designed to create a suction system to remove unwanted fluids or gases from laboratory working areas. The laboratory vacuum system package is compliant with

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Basics of Control Components

Basics of Control Components Basics of Control Components Table of Contents Introduction...2 Electrical Symbols...6 Line Diagrams...16 Overload Protection...22 Overload Relays...26 Manual Control...35 Magnetic Contactors and Starters...41

More information

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum . Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor circuit 5 =

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

MODEL SCA Installation and Operation Manual Important:

MODEL SCA Installation and Operation Manual Important: MODEL SCA Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible

More information

Section 17. Motor Control Centers. Table of Contents. Model 6 Motor Control Centers

Section 17. Motor Control Centers. Table of Contents. Model 6 Motor Control Centers Table of Contents Section 7 Model Motor Control Centers Motor Control Centers Structure and Unit Features 7- Merchandised Units General Information 7- Combination Starters with Motor Circuit Protector

More information

SP600 AC Drives MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3)

SP600 AC Drives MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3) MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3) SP Models: (4) Analog Input #1 (0-10 VDC or 4-20 ma) Analog Output (0-10 VDC) Refer to the Standard Motors and Drives Catalog for Standard features

More information

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION Instruction Bulletin Bulletin No. 0006-39-03 May 997 Raleigh, NC, USA Enclosed ALTISTART 6 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION This bulletin is a supplement to

More information

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL SECTION 23 04 10 ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Industrial Control & Circuit Breakers

Industrial Control & Circuit Breakers Industrial Control & Circuit Breakers Section C Innovative, intelligent NEC and IEC solutions safely and efficiently control power and protect circuits in explosive, wet, and corrosive environments worldwide.

More information

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide 32XR 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide RED ALARM LIGHT LEVEL CONTROLLER H-O-A SWITCHES HORN SILENCE INNER DOOR MOTOR STARTERS WITH INTERCHANGEABLE OVERLOAD MODULES

More information

Features and Benefits. Control Features

Features and Benefits. Control Features Features and Benefits AC induction motors have become increasingly dominant in industrial facilities worldwide. Manufacturers faced with increasing pressure to control costs have recognized that motor

More information

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable. Controls Express A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable. usa.siemens.com/controls-express Table of contents Starters at the speed

More information

www. ElectricalPartManuals. com CHARACTERISTICS

www. ElectricalPartManuals. com CHARACTERISTICS CHARACTERSTCS The EasyStart EA is a unique approach to solid state motor starting, combining the performance benefits expected from a solid state starter with the electrical efficiencies and small physical

More information

4.1. Definite Purpose Contactors and Starters. Contents

4.1. Definite Purpose Contactors and Starters. Contents . Definite Purpose and Starters Product Overview and Starters Definite Purpose and Starters Contents Description Page 20 0A, Compact Single- and Two-Pole C25................................ V5-T- 5 360A,

More information

Item Code Description Quantity 1001AG0055 CROSBY CLAMP FOR 5MM WIRE CA0060 TURNBUCKLE EYE/EYE 10 X 125MM 0

Item Code Description Quantity 1001AG0055 CROSBY CLAMP FOR 5MM WIRE CA0060 TURNBUCKLE EYE/EYE 10 X 125MM 0 Controlgear Products +27 () 97 6 sales@controlgear.co.za CHI Eaton stock items on hand as at Fri, 5//28, 4: GMT+2 AG55 CROSBY CLAMP FOR 5MM WIRE CA6 TURNBUCKLE EYE/EYE X 25MM 25T 9 CONTACT BLOCK N/O N/C

More information

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 3150A 30A 3000A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are: Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.

More information

Enclosed Starter Selection Guide. Featuring Snap-together Wiring Technology

Enclosed Starter Selection Guide. Featuring Snap-together Wiring Technology Enclosed Starter Selection Guide Featuring Snap-together Wiring Technology Enclosed Starter Wiring Made Easy How It Works Component wiring is color-coded by function. The wiring sleeve cover corresponds

More information

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

REVISIONS App PC. App Sud. App Thom TC 2014/03/25 /9 Rev Description Document format and number changed. Previous number 543-0.0.30 Rev n by TC 204/03/25 Sud TC 204/03/25 REVISIONS PC Thom VB LH Clyd r Act Issue Date YYYY/MM/DD Pending Pending Pending

More information

TDX - Taco Duplex Starter with

TDX - Taco Duplex Starter with Energy Management TDX - Taco Duplex Starter with Smartstart The TDX extends the life of your pumps by alternating control. It comes standard with underload protection, a enhanced class 10 electronic overload

More information

SECTION ENCLOSED CONTROLLERS

SECTION ENCLOSED CONTROLLERS SECTION 16420 ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

ESW/PESW. Non-Combination Starters

ESW/PESW. Non-Combination Starters ESW/PESW Enclosed Non-Combination General WEG offers non-reversing and non-combination magnetic starters up to 75HP at 460Vac (105). Featuring components that meet IEC design standards and UL horsepower

More information

SIEMENS. Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide E87010-A0151-T003-A1-49EC. September, 2017

SIEMENS. Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide E87010-A0151-T003-A1-49EC. September, 2017 SIEMENS September, 17 Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide Hazardous voltage. Will cause death, serious injury, or property damage. Always de-energize and ground

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits

More information

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature

More information

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers Instruction Leaflet IL0330300E Supersedes I.L. 7055C, Pages 8, Dated June 998 Instructions for A00, A0, A50 size 6, two- or three-pole non-reversing or reversing motor controllers Contents Description

More information

CWM_N NEMA Rated Contactors

CWM_N NEMA Rated Contactors Motors Automation Energy Transmission & Distribution Coatings CWM_N NEMA contactors have been a mainstay in the industrial marketplace in the US for decades. NEMA contactors were known for being robust

More information

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents 1 January 00 Reduced Voltage Motor Starters Contents Description Page Open Type S7, Intelligent Technologies (IT.) Soft Starters Product Description............................................. Application

More information

Small Project Product Selection Guide

Small Project Product Selection Guide Small Project Product Selection Guide At your GE Distributor today! Panelboards Transformers Safety Switches NEMA Combo Starters Lighting Contactors imagination at work Small Projects Same Day When you

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

Contactors & Starters Index

Contactors & Starters Index ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic

More information

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: SECTION 6 Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: 70 Application: IDEM Universal Gate Boxes (UGB-KLT) provide high level RFID coded interlocking and machine control

More information

MOTOR TERMINAL CONNECTIONS

MOTOR TERMINAL CONNECTIONS MOTOR TERMINAL CONNECTIONS Motor Classification Most of the industrial machines in use today are driven by electric motors Motors are classified according to the type of power used (AC or DC) and the motors

More information

HVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars

HVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars HVAC Drives Lenze AC Tech MCH Series Price Book May 2015 - US Dollars Document: pcmchusd-0515_a MCH Series Drives: Model Number Designation Code The MCH Series drives are rated for variable torque applications,

More information

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy.

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Fast. Easy. Reliable Controls Express A wide selection of enclosed NEMA controls now available with faster shipping as a standard. usa.siemens.com/control-express Table of Contents Starters at the speed

More information