1 General Information This publication is to be used for Eaton Plug and Play enclosures designed starters that accept the M22 series 22mm cover control devices. To install the cover control kit (Follow the steps below) Wiring Diagrams: FVNR NEMA and IEC starters/contactor Diagram #1 Step 1: for the Non-Combo unit NEMA type 1, remove the rectangular blank cover by pushing on the blank cover Nylon Fastener from the inside. This step is not required for the other Plug and Play NEMA type constructions. PUSH OUT FROM THE INSDE TO REMOVE THE COVER, EEMAC TYPE 1 ONLY Diagram #2 Step 2: Locate the mounting holes on the enclosure base to install the cover control kit and transformer or separate supply kits. The kits come with installation instructions and the hardware. CAUTION: READ AND FOLLOW INSTRUCTIONS PRIOR TO WIRING OR CONNECTING POWER. THIS PRODUCT CAN BE FACTORY OR FIELD CONFIGURED FOR MULTIPLE CONTROL MODES OR CONTROL VOLTAGES. CHECK THE COVER CONTROLS AND TRANSFORMER OR THE SEPARATE SUPPLY KITS FOR PROPER VOLTAGE BEFORE APPLYING POWER.
2 Typical Wiring diagrams: Enclosed starter/contactor assemblies supplied from factory are pre-wired as per figure A and B. Wiring Instructions: Figure A Figure B 1 REMOTE START CONTACT BETWEEN TERMINAL 1 AND 2 IS SUPPLIED BY THE CUSTOMER FOR THE HAND/OFF/AUTO KITS IN THE AUTO POSSITION. 2 ADDING A JUMPER BETWEEN TERMINAL 2 AND 3 IS REQUIRED FOR START/STOP PUSH BUTTON KITS AND IS SUPPLIED LOOSE. 3 A TERMINAL BLOCK JUMPER IS REQUIRED BETWEEN 4 AND 5 FOR TRANSFORMER KITS SECONDARY GROUNDING AND IS SUPPLIED WITH THE TRANSFORMER KITS. Various sub-assemblies are required to complete an assembly and are available in kit form for ease of installation by customers. These kits require minimal knowledge about the internal wire connections or installation tools. The following pages show the available kits. 1. Auxiliary contacts and the overload are not supplied in kit form but are available from your local distributors.
3 FVNR Cover Control Connections (Quick connect into the 5 pin connector) STOP-START (OFF-ON) Pushbutton (FIG. 1) STOP-START (OFF-ON) Selector Switch + Red (RUN) and Green (STOP) light (24Vac or 120Vac) (FIG. 5) STOP-START (OFF-ON) Pushbutton + Red (RUN) light (24Vac or 120Vac) (FIG. 2) HAND-OFF-AUTO (TEST-OFF-AUTO) Selector Switch (FIG. 6) STOP-START (OFF-ON) Selector switch (FIG. 3) HAND-OFF-AUTO (TEST-OFF-AUTO) Selector Switch + Red(RUN) light (24Vac or 120Vac) (FIG. 7) STOP-START (OFF-ON) Selector Switch + Red (RUN) light (24Vac or 120Vac) (FIG. 4) HAND-OFF-AUTO (TEST-OFF-AUTO) Selector Switch + Red (RUN) + Green (STOP) lights (24Vac or 120Vac) (FIG. 8)
4 FVNR Remote, CPT, No Cover Control and Separate Supply Connections (Quick connect into the 4 and 5 pin connector or to the Terminal Block) START/STOP Push Button Remote Kit (FIG. 9) C No Cover Control kit (FIG. 12) Seperate Supply 120Vac or 20Vac Control Kits (FIG. 14) START/STOP Selector Switch Remote Kit (FIG. 10) CPT Control Transformer Kits (FIG. 13) HOA Selector Switch Remote Kit (FIG. 11) Separate Supply 120Vac or 20Vac Control Kits (FIG. 14) Legends * Remote control device Wiring by others Terminal point connection in the plug and play unit X-CON For quick connectors, 2-CON, 4-CON and 5-CON for 2, 4 and 5 pin connectors respectively. Notes: 1. Normally Close (NC) auxiliary contact for OFF green light is included with the cover control kit (order separately). *For auxiliary contact catalog #, refer to the table on the enclosure cover label. 2. For assemblies without overload relay connect the 2 pin connector to the base assembly and marrett the wires 95 and 96 together.
5 Internal Accessories and Terminal Customer Connections Internal Customer Wiring Modification When Adding an Overload Note 1) for frame B move the A2 and 14NO wires to the A2 and 14NO on the overload Note 2) for frame C move the 14NO wires to the 14NO on the overload Field Modification Adding Auxiliary Contact Note 3) For frame B, C and D connect wires 95 and 96 to the NC contact of the overload Internal Field Wiring Modification for Lighting Application For frame B and C Mounted on top For frame D mounted on the left hand side MARRETT THE 2 WIRES, 95 AND 96 FOR LIGHTING AND RESISTIVE APPLICATION
6 Application specific ratings for the Plug and Play Termination Torque specifications for the Plug and Play
Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures
Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking
More informationEnclosed Full-Voltage Starters
GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for
More informationEnclosed Full-Voltage Starters
GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides
More informationEnclosures. See Section Typical Description
January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic
More information3. Coils shall be of molded construction
.7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationMotors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters
Motors Automation Energy Transmission & Distribution Coatings GPH2 Combination Soft Starters GPH2 Combination Soft Starter 5to 350 HP The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general
More informationA. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:
SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More information3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...
Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp
More informationSECTION MOTORS & MOTOR CONTROLLERS
SECTION 15170 MOTORS & MOTOR CONTROLLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Electric motors. B. Motor controllers for Packaged equipment. 1.02 SUBMITTALS A. Wiring diagrams with electrical characteristics
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)
804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit
More informationECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9
February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR
More informationGPH2 Combination Soft Starters
Combination Soft Starters The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general purpose AC motor soft starter package. It is designed for simple and quick installation and start-up, requiring
More informationQuick selector reference guide. Motor Control Center Aftermarket Buckets
Quick selector reference guide Motor Control Center Aftermarket Buckets 2 EATON WWW.EATON.COM/MCCAFTERMARKET Table of contents Series 2100 MCC bucket Motor Control Center (MCC) Aftermarket Buckets Overview
More informationApplications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes
AE Threaded Combination and Non-Combination Full Motor Starters Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Class I, Division and, Groups C, D Class II, Division
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More informationSoftstarters Type PSS. Softstarters. General information
General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide
More informationOperation and Protection of Motors up to 600Hp at 460Vac (800A)
Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components
More informationMotors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11
Motors Automation Energy Transmission & istribution Coatings EP11 Enclosed rive Panel USA EP11 EP11 Enclosed rive Panel The Enclosed rive Panel is an industrial general purpose AC motor control and protection
More informationSoftstarters. Softstarters Power electronic brakes Type PEB
Softstarters Power electronic brakes Softstarters Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB)
More information331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH
331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing
More informationNEMA Vacuum Break Contactors and Starters
NEMA Vacuum Break Contactors and Starters NEMA Vacuum Break Starter.1 Product Description....................................... Application Description.................................... Operation...............................................
More informationSuitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators
SafeLine Compact, heavy duty disconnect 6A 200A 30A 200A Fusible Disconnect SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings
More informationNMC Combination Line Starters and Enclosures
NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line
More informationGPH2. Soft Starters. Applications. Standard Features. Centrifugal Pumps Screw Compressors Centrifugal Fans Wood Chipper Veneer Lathe Saw Conveyor
The Combination Soft is a NEMA 4/12 Enclosed industrial general purpose AC motor soft starter package. It is designed for simple and quick installation and start-up, requiring only input power and output
More informationStandard Materials Bodies and covers: copper-free aluminum.
-26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and
More informationCIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES
CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic
More informationProgrammable Logic Controller. Mat Nor Mohamad
Programmable Logic Controller Mat Nor Mohamad Relays Electromagnetic Control Relays The PLC's original purpose was the replacement of electromagnetic relays with a solid-state switching system that could
More informationNEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry
NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. usa.siemens.com/controls
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed
More informationBAC Custom Engineered Controls
BAC Custom Engineered Controls Product Detail Product Introduction......................................... K2 BAC Custom Engineered Controls Benefits....................................................
More informationIEC Utilization Categories (Explanation)
IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC
More informationEBMC Combination Line Starters and Enclosures
EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,
More information6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum
.1 Catalog Number Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor
More informationType E/F Simplex & Duplex Pump Controllers
Type E/ Simplex & Duplex Pump Controllers Simplex Pump Controllers A single KTA7 motor controller plus matching CA7 contactor can be combined in an enclosure as a Simplex Combination Controller for pumping
More informationSED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.
SED2 with Conventional Bypass Options Important Note: VD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies
More informationOperation and Protection of Motors up to 600Hp at 460Vac (800A)
Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components
More informationControls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy.
Fast. Easy. Reliable Controls Express A wide selection of enclosed NEMA controls now available with faster shipping as a standard. usa.siemens.com/controls-express Table of Contents Starters at the speed
More informationMove to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers
Move to modern enclosed disconnect switch technology Enclosed disconnect switches eot Manual motor controllers The next generation of enclosed disconnect switches... Cutting edge design and technology
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:
More informationBulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents
Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationHVW701 HVAC Drive with By-Pass
s Automation Energy Transmission & Distribution Coatings HVW701 HVAC with By-Pass Designed Especially for HVAC Systems US.HVW701.By-Pass.07/2017 www.weg.net WEG HVAC-R Products WEG, a leading supplier
More informationNEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry
NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls
More informationControls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.
Controls Express A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable. usa.siemens.com/controls-express Starters at the Speed You Need Siemens
More informationAdvantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.
Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems
More information1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.
SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary
More informationPower electronic brakes
Power electronic brakes Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB) Series features full-wave
More informationCM Lodestar Electric Chain Hoist Electrical Parts List
CM Lodestar Electric Chain Hoist Electrical Parts List MODELS Key No. Part Name No. Req'd A, A-2, AA, AA-2, B, B-2 C, C-2, E, E-2, F, F- 2, H & H-2 J, J-2, JJ, JJ-2, L, L-2, LL, LL-2, R, R- 2, RR, RR-2,
More informationCatalog Number Identification with Elements Explained
Installation Manual 920 Remote Control Switches 30 through 225 ampere sizes This Installation! Manual is for green nameplate ASCO 920s only. For black nameplate ASCO 920s refer to Owners Manual 2D4920
More informationInstrument Enclosure Assemblies
Instrument Enclosure Assemblies Standard instrument enclosure Instrument enclosures offer a simple solution for the customer who doesn t have the time to install Signet meters into panels. Whether it s
More informationThe Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller
The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the
More informationSIEMENS. Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide E87010-A0151-T003-A1-49EC. August, 2012
SIEMENS August, 12 Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide Hazardous voltage. Will cause death, serious injury, or property damage. Always de-energize and ground the
More informationSoftstarters Type PSR. Softstarters
Type PSR Type PSR Type PSR General information Designed for motor currents from 3 to 45 A, PSR complement the existing advanced PST for 30-1050 A and the flexible PSS for 30-1050 A. The PSR Softstarter
More informationO-3. Compliances UL Classified UL 508, 698, 1203 NEMA 4, 4X, 7CD, 9EFG For CSA approvals, please consult factory.
Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. -3 Applications AE series threaded type combination
More informationPRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:
Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationPage 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut
Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker
More informationOpen & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection
Reduced voltage starters Open & enclosed Reduced voltage starters Description Compact, space saving design 8 starter frame sizes, A16 to A750 Maximum U.L. horsepower ratings Mechanically interlocking as
More informationCutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter
Operation, and Maintenance of the Instruction Bulletin Read and understand these instructions before attempting any installation, operation, or maintenance of the. This equipment shall be installed and
More informationMultiple vacuum pumps and associated equipment ASME air receiver NEMA 12 multiplex control panel
GENERAL The Powerex laboratory vacuum system is designed to create a suction system to remove unwanted fluids or gases from laboratory working areas. The laboratory vacuum system package is compliant with
More informationDesign Standard. Purpose: Design Standard:
Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard
More informationBasics of Control Components
Basics of Control Components Table of Contents Introduction...2 Electrical Symbols...6 Line Diagrams...16 Overload Protection...22 Overload Relays...26 Manual Control...35 Magnetic Contactors and Starters...41
More information6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum
. Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor circuit 5 =
More informationFor Options, Modifications and Accessories, see pages Discount Schedule A6
Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F
More informationMODEL SCA Installation and Operation Manual Important:
MODEL SCA Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible
More informationSection 17. Motor Control Centers. Table of Contents. Model 6 Motor Control Centers
Table of Contents Section 7 Model Motor Control Centers Motor Control Centers Structure and Unit Features 7- Merchandised Units General Information 7- Combination Starters with Motor Circuit Protector
More informationSP600 AC Drives MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3)
MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3) SP Models: (4) Analog Input #1 (0-10 VDC or 4-20 ma) Analog Output (0-10 VDC) Refer to the Standard Motors and Drives Catalog for Standard features
More informationInstruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION
Instruction Bulletin Bulletin No. 0006-39-03 May 997 Raleigh, NC, USA Enclosed ALTISTART 6 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION This bulletin is a supplement to
More informationUniversity of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL
SECTION 23 04 10 ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationIndustrial Control & Circuit Breakers
Industrial Control & Circuit Breakers Section C Innovative, intelligent NEC and IEC solutions safely and efficiently control power and protect circuits in explosive, wet, and corrosive environments worldwide.
More information32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide
32XR 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide RED ALARM LIGHT LEVEL CONTROLLER H-O-A SWITCHES HORN SILENCE INNER DOOR MOTOR STARTERS WITH INTERCHANGEABLE OVERLOAD MODULES
More informationFeatures and Benefits. Control Features
Features and Benefits AC induction motors have become increasingly dominant in industrial facilities worldwide. Manufacturers faced with increasing pressure to control costs have recognized that motor
More informationControls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.
Controls Express A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable. usa.siemens.com/controls-express Table of contents Starters at the speed
More informationwww. ElectricalPartManuals. com CHARACTERISTICS
CHARACTERSTCS The EasyStart EA is a unique approach to solid state motor starting, combining the performance benefits expected from a solid state starter with the electrical efficiencies and small physical
More information4.1. Definite Purpose Contactors and Starters. Contents
. Definite Purpose and Starters Product Overview and Starters Definite Purpose and Starters Contents Description Page 20 0A, Compact Single- and Two-Pole C25................................ V5-T- 5 360A,
More informationItem Code Description Quantity 1001AG0055 CROSBY CLAMP FOR 5MM WIRE CA0060 TURNBUCKLE EYE/EYE 10 X 125MM 0
Controlgear Products +27 () 97 6 sales@controlgear.co.za CHI Eaton stock items on hand as at Fri, 5//28, 4: GMT+2 AG55 CROSBY CLAMP FOR 5MM WIRE CA6 TURNBUCKLE EYE/EYE X 25MM 25T 9 CONTACT BLOCK N/O N/C
More informationSuitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators
SafeLine Compact, heavy duty disconnect 16A 3150A 30A 3000A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational
More informationInstallation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor
World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com
More informationTypes of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:
Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.
More informationEnclosed Starter Selection Guide. Featuring Snap-together Wiring Technology
Enclosed Starter Selection Guide Featuring Snap-together Wiring Technology Enclosed Starter Wiring Made Easy How It Works Component wiring is color-coded by function. The wiring sleeve cover corresponds
More informationREVISIONS App PC. App Sud. App Thom TC 2014/03/25
/9 Rev Description Document format and number changed. Previous number 543-0.0.30 Rev n by TC 204/03/25 Sud TC 204/03/25 REVISIONS PC Thom VB LH Clyd r Act Issue Date YYYY/MM/DD Pending Pending Pending
More informationTDX - Taco Duplex Starter with
Energy Management TDX - Taco Duplex Starter with Smartstart The TDX extends the life of your pumps by alternating control. It comes standard with underload protection, a enhanced class 10 electronic overload
More informationSECTION ENCLOSED CONTROLLERS
SECTION 16420 ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSIGNAL WORDS QUALIFIED PERSON
SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or
More informationESW/PESW. Non-Combination Starters
ESW/PESW Enclosed Non-Combination General WEG offers non-reversing and non-combination magnetic starters up to 75HP at 460Vac (105). Featuring components that meet IEC design standards and UL horsepower
More informationSIEMENS. Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide E87010-A0151-T003-A1-49EC. September, 2017
SIEMENS September, 17 Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide Hazardous voltage. Will cause death, serious injury, or property damage. Always de-energize and ground
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits
More informationMotors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB
Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature
More informationInstructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers
Instruction Leaflet IL0330300E Supersedes I.L. 7055C, Pages 8, Dated June 998 Instructions for A00, A0, A50 size 6, two- or three-pole non-reversing or reversing motor controllers Contents Description
More informationCWM_N NEMA Rated Contactors
Motors Automation Energy Transmission & Distribution Coatings CWM_N NEMA contactors have been a mainstay in the industrial marketplace in the US for decades. NEMA contactors were known for being robust
More informationMotor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents
1 January 00 Reduced Voltage Motor Starters Contents Description Page Open Type S7, Intelligent Technologies (IT.) Soft Starters Product Description............................................. Application
More informationSmall Project Product Selection Guide
Small Project Product Selection Guide At your GE Distributor today! Panelboards Transformers Safety Switches NEMA Combo Starters Lighting Contactors imagination at work Small Projects Same Day When you
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements
More informationContactors & Starters Index
ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic
More informationUniversal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:
SECTION 6 Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: 70 Application: IDEM Universal Gate Boxes (UGB-KLT) provide high level RFID coded interlocking and machine control
More informationMOTOR TERMINAL CONNECTIONS
MOTOR TERMINAL CONNECTIONS Motor Classification Most of the industrial machines in use today are driven by electric motors Motors are classified according to the type of power used (AC or DC) and the motors
More informationHVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars
HVAC Drives Lenze AC Tech MCH Series Price Book May 2015 - US Dollars Document: pcmchusd-0515_a MCH Series Drives: Model Number Designation Code The MCH Series drives are rated for variable torque applications,
More informationControls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy.
Fast. Easy. Reliable Controls Express A wide selection of enclosed NEMA controls now available with faster shipping as a standard. usa.siemens.com/control-express Table of Contents Starters at the speed
More information