ABCS GRP Control Stations

Size: px
Start display at page:

Download "ABCS GRP Control Stations"

Transcription

1 ABCS GRP Control Stations Application Industrial and Hazardous areas IP65/66 Protection Degree IP66 (IP65 when fitted with an ammeter) Certification ATEX & IECEx Ex e II T4 or Ex ed IIC T4 Material Glass Reinforced Polyester (RAL 7001 grey) or Carbon Loaded Glass Reinforced Polyester (Black) Configuration options (see typical layout drawings overleaf) Part Dimensions Max. Power Maximum Populations Number HxWxD (mm) Dissipation (W) Operators Only W/ Terminals W/ Ammeter W/ Ammeter & Terminals ABCS6 122x120x x Op N/A N/A N/A ABCS7 220x120x x Op 2 x Op 1 x Op, 1 x Am 1 x Am ABCS8 160x160x x Op 2 x Op 1 x Am N/A ABCS9 260x160x x Op 5 x Op 4 x Op, 1 x Am 2 x Op, 1 x Am ABCS10 360x160x x Op 5 x Op 4 x Op, 2 x Am 2 x Op, 2 x Am ABCS11 560x160x x Op 8 x Op 7 x Op, 3 x Am 6 x Op, 3 x Am ABCS12 255x250x x Op 6 x Op 6 x Op, 2 x Am 4 x Op, 2 x Am ABCS13 400x250x x Op 9 x Op 8 x Op, 4 x Am 4 x O, 2 x Am ABCS14 600x250x x Op 14 x Op 12 x Op, 6 x Am 9 x Op, 6 x Am ABCS15 400x405x x Op 15 x Op 12 x Op, 6 x Am 10 x Op, 6 x Am Op = Operator (Push Button, E Stop, Indicator Lamp or Selector Switch) Allow 1W power dissipation per operator Am = Ammeter Allow 0.5W power dissipation per ammeter Available operator, ammeter and terminal types (see parts list overleaf) Push Button Emergency Stop Mushroom Head Key Release Push Button Indicator Lamp Illuminated Push Button Selector Switch Ammeter Terminals Momentary, 1NC/1NO, 2NC or 2NO. Coloured/marked inserts as required Push Pull, 1NC/1NO, 2NC or 2NO. Red/yellow mushroom head Push Pull, 1NC/1NO, 2NC or 2NO. Colour: black. Optional key release 1NC/1NO, 2NC or 2NO. Colour: black Red/green/yellow/blue or white available Red/green/yellow/blue or white available. Available with 1NC or 1NO 2 or 3 position. 2 pole contact configurations and label inserts to suit application Small switch handle (39mm dia) as standard. Large handle (60mm dia) also available Direct measuring with x2 overload scale (max scale: 0 15A/30A) 1A or 5A current transformer with x2 or x5 overload scale (max scale: 0 600A/3000A) Direct termination as standard, 2.5/4mm² Ex screw terminals fitted where requested ABDS 12rev 00

2 Maximum cable entries Top face Bottom face M20 M25 M32 M40 M20 M25 M32 M40 ABCS N/A N/A ABCS7 1 1 N/A N/A 1 1 N/A N/A ABCS N/A N/A ABCS N/A N/A ABCS N/A N/A ABCS N/A N/A ABCS ABCS ABCS ABCS Ordering information Electrical data Push Button Utilization category (per BS EN ) AC12 AC15 DC13 DC13 Emergency Stop Rated voltage 250V 250V 110V 24V Mushroom Head Rated current 16A 10A 0.5A 1A Key Release Push Button Maximum ambient temperature +40 C +60 C +60 C +60 C Indicator Lamp Suitable for Vac / 24 36Vdc supply. Alternative supply option: Vac Utilization category (per BS EN ) AC15 DC13 Rated voltage 250V 24V Illuminated Push Button Rated current 6A 1A Maximum ambient temperature +60 C +60 C Lamp suitable for Vac / 24 36Vdc supply Terminal type AKZ 2.5 AKZ 4 SAK 2.5 SAK 4 Terminals Maximum cable size 2.5mm² 4mm² 2.5mm² 4mm² Maximum voltage 176V 275V 550V 550V Maximum current 21A 28A 21A 28A Contact details Abtech Limited Sanderson Street Sheffield, S9 2UA United Kingdom ABDS 12 rev 00 t : +44 (0) f : +44 (0) e : sales@abtech.eu

3 ABCS GRP Control Stations OPERATORS ONLY W/ TERMINALS W/ AMMETER W/ AMMETER & TERMINALS ABCS6/1 0 ABCS7/3 0/***** ABCS7/2 0/*****/T ABCS7/1 1 ABCS7/0 1/T ABCS8/4 0/***** ABCS8/2 0/*****/T ABCS8/0 1 ABCS9/5 0/***** ABCS9/5 0/*****/T ABCS9/4 1/***** ABCS9/2 1/*****/T ABCS10/6 0/***** ABCS10/6 0/*****/T ABCS10/4 2/***** ABCS10/2 2/*****/T ABDS 20 rev 00

4 ABCS11/9 0/***** ABCS11/8 0/*****/T ABCS11/7 3/***** ABCS11/6 3/*****/T ABCS12/7 0/***** ABCS12/6 0/*****/T ABCS12/6 2/***** ABCS12/4 2/*****/T ABCS13/10 0/***** ABCS13/9 0/*****/T ABCS13/8 4/***** ABCS13/6 4/*****/T ABCS14/15 0/***** ABCS14/14 0/*****/T ABCS14/12 6/***** ABCS14/9 6/*****/T ABCS15/15 0/***** ABCS15/15 0/*****/T ABCS15/12 6/***** ABCS15/10 6/*****/T ABDS 20 rev 00

5 PARTS LIST Control Stations Part Code Part Description Contact Configuration Typical Part Image COP170xx COP160xx COP171xx COP161xx COP172xx COP162xx COP370 COP360 COP371 COP361 COP372 COP362 COY070 COY060 COY071 COY061 COY072 COY062 COP470 COP460 COP471 COP461 COP472 COP462 P1 Push button, 1NC/1NO P1 Push button, 2NC P1 Push button, 2NO CODE LEGEND LABEL COLOUR TEXT COLOUR CODE LEGEND LABEL COLOUR TEXT COLOUR 01 "BLANK" Green N/A 41 "BLANK" White N/A 02 I Green White 42 II White Black 03 ON Green White 43 White Black 04 START Green White 44 START White Black 21 "BLANK" Red N/A 45 STOP White Red 22 O Red White 46 FW White Black 23 OFF Red White 47 BW White Black 24 STOP Red White 49 White Black 61 "BLANK" Yellow N/A 81 "BLANK" Black N/A 62 II Yellow White P3 E stop mushroom head, 1NC/1NO P3 E stop mushroom head, 2NC P3 E stop mushroom head, 2NO E stop mushroom head, key release, 1NC/1NO E stop mushroom head, key release, 2NC E stop mushroom head, key release, 2NO P4 Black mushroom head, 1NC/1NO P4 Black mushroom head, 2NC P4 Black mushroom head, 2NO ABDS 15 rev 00

6 Part Code Part Description Contact Configuration Typical Part Image COY170 COY160 COY171 COY161 COY172 COY162 Push button, key release, 1NC/1NO Push button, key release, 2NC Push button, key release, 2NO Part Code Part Description Voltage Range Typical Part Image CLLR7R1 CLLR6R1 CLLG7G1 CLLG6G1 CLLY7Y1 CLLY6Y1 CLLB7B1 CLLB6B1 CLLW7W1 CLLW6W1 CLLR7R2 CLLR6R2 CLLG7G2 CLLG6G2 CLLY7Y2 CLLY6Y2 CLLB7B2 CLLB6B2 CLLW7W2 CLLW6W2 Indicator lamp, Red Indicator lamp, Green Indicator lamp, Yellow Indicator lamp, Blue Indicator lamp, White Indicator lamp, Red Indicator lamp, Green Indicator lamp, Yellow Indicator lamp, Blue Indicator lamp, White VAC 24 36VDC VAC Part Code Part Description Contact Configuration/Voltage Range Typical Part Image COPR73R1 COPR63R1 COPG73G1 COPG63G1 COPY73Y1 COPY63Y1 COPB73B1 COPB63B1 COPW73W1 COPW63W1 COPR74R1 COPR64R1 COPG74G1 COPG64G1 COPY74Y1 COPY64Y1 COPB74B1 COPB64B1 COPW74W1 COPW64W1 Illuminated PB, Red (1NC) Illuminated PB, Green (1NC) Illuminated PB, Yellow (1NC) Illuminated PB, Blue (1NC) Illuminated PB, White (1NC) Illuminated PB, Red (1NO) Illuminated PB, Green (1NO) Illuminated PB, Yellow (1NO) Illuminated PB, Blue (1NO) Illuminated PB, White (1NO) VAC 24 36VDC VAC 24 36VDC ABDS 15 rev 00

7 Part Code Part Description Label Contact Schematic Typical Part Image COK47003 COK46003 COK47204 COK46204 COK57204 COK56204 COK57003 COK56003 COK67201 COK66201 COK67002 COK66002 COK87005 COK86005 self reset, "0 I II" self reset, "I 0 II" self lock, "I 0 II" self lock, "0 I II" 2 position small handle, self lock, "0 I" 2 position small handle, self lock, "I II" self lock/reset, "0 I" Part Code Measuring Method Measuring Range Overload Scale Typical Part Image CAM7WAxx/1 2 1A CT x2 CAM6WAxx/1 2 1A CT x2 CAM7WAxx/1 5 5A CT x5 CAM6WAxx/1 5 5A CT x5 See below CAM7WAxx/5 2 1A CT x2 CAM6WAxx/5 2 1A CT x2 CAM7WAxx/5 5 5A CT x5 CAM6WAxx/5 5 5A CT x5 AMMETER SCALES CACZ A/ 0 1A 2A or 5A CACZ A/ 0 2.5A 5A or 12.5A CACZ A/ 0 5A 10A or 25A CACZ A/ 0 15A 30A or 75A CACZ A/ 0 25A 50A or 125A CACZ A/ 0 40A 80A or 200A CACZ A/ 0 50A 100A or 250A CACZ A/ 0 60A 120A or 300A 1A or 5A CACZ A/ 0 75A 150A or 375A current transformer CACZ A/ 0 100A 200A or 500A CACZ A/ 0 150A 300A or 750A CACZ A/ 0 200A 400A or 1000A CACZ A/ 0 250A 500A or 1250A CACZ A/ 0 300A 600A or 1500A CACZ A/ 0 400A 800A or 2000A CACZ A/ 0 500A 1000A or 2500A CACZ A/ 0 600A 1200A or 3000A "2" or "5" (x2 or x5 overload scale) "1" or "5" (1A or 5A current transformer) ABDS 15 rev 00

I Ex-safety switches I

I Ex-safety switches I EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX

More information

Control Buttons / Switches for Panel Mounting Series 8003

Control Buttons / Switches for Panel Mounting Series 8003 www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch > 2 contact elements > Spring clamp

More information

I Ex-Safety switches I

I Ex-Safety switches I 3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX

More information

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

HKH Series. HAZCON Controls for Harsh and Hazardous Environments HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective

More information

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC

More information

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13 Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.

More information

SPARES & ACCESSORIES. FLAMEPROOF Ex-d Components. IP rating Ambient temperature range Approvals. Marking. Barrel thread

SPARES & ACCESSORIES. FLAMEPROOF Ex-d Components. IP rating Ambient temperature range Approvals. Marking. Barrel thread FLAMEPROOF Ex-d Components Ex-d components are available in a wide range of operators/pilot lights PL series and selectors PSRC series; allow numerous combinations with our CP../CPS.. EFDCN/EFSRC series.

More information

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS Z A H LO C ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS BASIC CATALOG NUMBERS HKHPBMMSS1 HKHPBMMTC1 HKHPBILLMM1 HKHPBMMMR1 HKHPBMMMB1 HKHPBMMMG1 HKHDBLPBMMGR1 HKHPBPMTMR1 HKHPBPMTMB1 HKHPBPMTMG1 HKHPBTMTMR1

More information

I Ex-safety switches I

I Ex-safety switches I 3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99

More information

Panelboards & Motor Starters

Panelboards & Motor Starters Appleton s ATX series of Increased Safety distribution panels are available in IP66-rated fiberglass reinforced polyester (FRP) or 316L stainless steel and come in multiple sizes depending on the number

More information

Junction boxes for control, monitoring and control panel Ex tb

Junction boxes for control, monitoring and control panel Ex tb Junction boxes for control, monitoring and control panel - Zone 21, 22 - Category 2D - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products Inspection window Padlockable

More information

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist

More information

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2. 8 Innovations 2/2 - Control panel BDF 2 BDF 2 5.5 22 29 39 3 4 6- Slim, shock-resistant plastic enclosure Can be fitted onto customary aluminium profile systems Can be installed in the most favourable

More information

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC.

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC. SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC CONTROL UNITS SWITCH DISCONNECTORS & CAM SWITCHES TOP-TECHNIC TOP-TECHNIC EMERGENCY STOP MAIN SWITCHES MAIN SWITCHES TOP-TECHNIC TOP-TECHNIC CAM SWITCHES FOR

More information

9 Control Equipment. Control Unit System Series ConSig 8040

9 Control Equipment. Control Unit System Series ConSig 8040 9 Control Equipment Control Unit System Explosion protection to CENELEC IEC NEC Can be used in Zone 1 and Zone 2 Standard and customized units 3 sizes available Enclosures in glass fibre reinforced polyester

More information

Ordering details. BDF 100-➀-➁-➂-ST No. Option Description. ➀ 20 2 NO contacts 11 1 NO contact / 1 NC contact ➁ Selection of the actuator ➂

Ordering details. BDF 100-➀-➁-➂-ST No. Option Description. ➀ 20 2 NO contacts 11 1 NO contact / 1 NC contact ➁ Selection of the actuator ➂ BDF -NH BDF Technical data 3 39 6 4 8 8 M 5 5.5 69.5 Yellow enclosure cover Slim, shock-resistant plastic enclosure Can be fitted onto customary aluminum profile systems Can be installed in the most favorable

More information

Control & Signalling Devices 22.5 mm. RoHS. Compliant

Control & Signalling Devices 22.5 mm. RoHS. Compliant Control & Signalling Devices 22.5 mm RoHS Compliant Contents Characteristics General Characteristics Products Push Buttons, Selector Switches, Latching Mushroom Head Push Buttons, Pilot Lights & Illuminated

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

GHG43 Series Control Stations

GHG43 Series Control Stations GHG43 Series Control Stations Nonmetallic or 316L Stainless Steel UL/cUL listed Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, (A) Ex de IIB + H2 T6 Cl. II, Div. 1, Groups E, F, G (cul) PTB ATEX

More information

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Main current switches >180 A are realized in metal enclosures. Internationally approved. E X - M A I N C U R R E N T S W I T C H E S 10 A - 80 A (up to 630 A) CEAG main current switches in a number of versions can be protected against inadvertent switching on by our integrated locking facility

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:

More information

M-0. M-0... series control, monitoring and signalling devices. Ex e

M-0. M-0... series control, monitoring and signalling devices. Ex e M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere

More information

EX-REPAIR AND MAINTENANCE RECEPTACLES

EX-REPAIR AND MAINTENANCE RECEPTACLES EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

STAINLESS STEEL PANEL MOUNT

STAINLESS STEEL PANEL MOUNT Z A H LO C STAINLESS STEEL PANEL MOUNT Optional Legend Plate Cover Screw Retaining Washer Panel Mount Bracket Explosion Protective LED Pilot Light Stainless Steel Washer Actuator Spacer Locknut Explosion

More information

Control Units Ex e Glass Fiber Reinforced Polyester

Control Units Ex e Glass Fiber Reinforced Polyester Features Assembly Glass fiber reinforced polyester (GRP) enclosures Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex de, Ex ib and Ex tb Up to 4 operators per control unit, base-mounted contact

More information

IP65. action. Guard Flap cover non-locking. Legend Printed flap cover. Dims. D5. action. Guard Flap cover non-locking. Legend Printed flap cover

IP65. action. Guard Flap cover non-locking. Legend Printed flap cover. Dims. D5. action. Guard Flap cover non-locking. Legend Printed flap cover General Description Die-cast 1N/C+1N/O (MT-16A) Emergency Power Off or EPO control stations can be used where the safety requirements associated with Emergency Stops are not required. Typical uses would

More information

I Ex-control stations I

I Ex-control stations I Type 11 83 Type 11 82 Type 11 81 Technical data Ex-control stations Type 11 81 I Type 11 82 I Type 11 83 Marking accd. to 9/9/EC II 2 G Ex ed ib m IIC T6 II 2 D Ex td A21 IP66 T80 C EC-Type Examination

More information

LED Linear Luminaire Series EXLUX 6402

LED Linear Luminaire Series EXLUX 6402 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

C & S 22 mm NON-ILLUMINATED PUSHBUTTONS METAL BEZEL

C & S 22 mm NON-ILLUMINATED PUSHBUTTONS METAL BEZEL C & S 22 mm NON-ILLUMINATED PUSHBUTTONS METAL BEZEL OPERATING HEADS, - IP65 CONTROL UNITS WITH CHROMIUM PLATED METAL BEZEL PROJECTING PUSH BUTTON BOOTED PUSH BUTTON IP66 WITH TRANSPARENT BOOT IP66 MUSHROOM

More information

Industrial & Hazardous Area Electrical Equipment

Industrial & Hazardous Area Electrical Equipment Industrial & azardous Area Electrical Equipment 2017.2 Abtech has been supplying electrical connec on products to hazardous and industrial markets since the 1970 s. Our range includes hazardous area ligh

More information

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600 > 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600

More information

Linear luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002 > latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Control Buttons Series 8082

Control Buttons Series 8082 www.stahl.de > Contact element with 1 NO contact 1 NC contact, positive opening > Contact material silver-nickel or gold-plated > 9 different actuators Push Mushroom push Selector switch Rotary actuator

More information

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108 Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Plastic enclosures compact Of polycarbonate. Degree of protection: IP 66, 67, 69K UL type1, 3R, 4, 4X, 12, 13

Plastic enclosures compact Of polycarbonate. Degree of protection: IP 66, 67, 69K UL type1, 3R, 4, 4X, 12, 13 Pilot devices, 22 mm Assembled stations and enclosures Assembled stations There are assembled stations of two types: In plastic enclosures and in metallic enclosures Both types of enclosures are available

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

EXEL-L. Detail of the internal side. Transparent polycarbonate

EXEL-L. Detail of the internal side. Transparent polycarbonate EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Terminal Boxes in Stainless Steel SLS**.T

Terminal Boxes in Stainless Steel SLS**.T Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations

More information

ATX D Series Actuators, Pilot Lights, Contact Blocks, Switches and Accessories Flameproof

ATX D Series Actuators, Pilot Lights, Contact Blocks, Switches and Accessories Flameproof ATX D Series Actuators, Pilot Lights, Contact Blocks, Switches and Accessories Applications Suitable for use with certified flameproof Ex d enclosures for control equipment. Features DIN rail mounted (TS35)

More information

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,

More information

Load disconnect switch Series 8146/5-V11

Load disconnect switch Series 8146/5-V11 www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation

More information

Safety Switches Series 8537

Safety Switches Series 8537 Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part

More information

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked

More information

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: alligator clip auxiliary

More information

Glass Reinforced Polyester Enclosures

Glass Reinforced Polyester Enclosures 42 The GRP range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,

More information

The ultimate low voltage temporary LED lighting solution

The ultimate low voltage temporary LED lighting solution LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkExTM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts

More information

Push Button Units and Indicator Lights

Push Button Units and Indicator Lights 3SB3, Inscriptions, 22 mm Insert labels Push Button Units and Indicator Lights Push buttons (clear) and illuminated push buttons with a flat button can be fitted with insert labels for identification purposes,

More information

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: SECTION 6 Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: 70 Application: IDEM Universal Gate Boxes (UGB-KLT) provide high level RFID coded interlocking and machine control

More information

PY, SPY; FSQC, FP; EPC; AP

PY, SPY; FSQC, FP; EPC; AP Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning

More information

KPB 25 W M R &30 CONTROL COMPONENTS. Push Button Switches. KPB, KSL, KPL and KBL series are designed for a wide range applications.

KPB 25 W M R &30 CONTROL COMPONENTS. Push Button Switches. KPB, KSL, KPL and KBL series are designed for a wide range applications. 25&3 CONTROL COMPONENTS KPB, KSL, KPL and KBL series are designed for a wide range applications. The contact material is Ag alloy. Protection IP4 or IP65 is available. Finger proof structure UL approved

More information

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A .1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps .4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control

More information

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: SECTION 6 Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: 78 Application: IDEM Universal Gate Boxes (UGB-KLT) provide high level RFID coded interlocking and machine control

More information

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C... EJB Enclosures ATEX and IECEx Zone 1 certified Explosion proof Marine grade copper-free aluminium IP66 The EJB Series is a range of explosion-proof enclosures, available in either aluminium alloy (EJB)

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

RAFIX 22 QR. General data. Content

RAFIX 22 QR. General data. Content QR General data QR control component range For a mounting hole diameter of.3 mm to IEC 60947 50V/10A max. Water-jet proof IP65 collar shapes The lamps of the pushbuttons can also be replaced from the front

More information

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range. General data QR control component range For a mounting hole diameter of.3 mm to IEC 60947 50V/10A max. Water-jet proof IP65 collar shapes The lamps of the pushbuttons can also be replaced from the front

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size Technical data UL Pilot Devices General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions

More information

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22) .15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent

More information

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC > For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES Ex d IIB+H 2 ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES ALUMINIUM ENCLOSURES STAINLESS STEEL ENCLOSURES EJB... series enclosures offer Ex d IIB +H 2 mode of protection. These enclosures are

More information

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6409/1 > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually

More information

Control & Indicating Devices

Control & Indicating Devices Control & Indicating Devices 22.5mm Push Buttons, Selector Switches & Pilot Lights Push Buttons Page 7.2 Emergency Push Buttons Page 7. Pilot Lights Page 7. Selector Switches Page Accessories Page 7.6

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact

More information

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series Ex d S S.1 series - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67 SSC series Temperature sensor box SWS series SF series A.117 S... series Junction boxes

More information

Load and Motor Switches, Load-Break Switches Series 8549

Load and Motor Switches, Load-Break Switches Series 8549 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Pick-off terminal block Auxiliary

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

Internationally approved.

Internationally approved. E X - M A N U A L M O T O R S T A R T E R S Up to 2 A Motors have to be protected against over loads, phase failures and overheating: CEAG s power circuit breaker and manual motor starter features phase-failure

More information

Ex UPS standard Series 8265

Ex UPS standard Series 8265 > Guard battery monitoring according to IEC/EN 60079 et seq. > Adjustable buffer time > Battery function test > Potential-free signal outputs > Maximum efficiency > Increased for reliable triggering of

More information

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

HKH Series. HAZCON Controls for Harsh and Hazardous Environments (93) A ø 0.2" (ø 5.5) 1.9 (4 3.7" (93) B A " 0) 8" 0) HKH Series HAZCON Controls for Harsh and Hazardous Environments 0.2" (5.5) 0.2" (5.5) 3.1" (80) 2.8" (70) ø 0.2" (ø 5.5) 1.9" (48) 3.7" (93) A B 0.2"

More information

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1 S P E C I F I C A T I O N Edition 2 Page 1 ECS - INDUSTRIAL CONTROL SWITCH SELECTOR 1. FEATURES Up to 5 different operations. Detachable contact block for easy installation and removal. It can meet variety

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated

More information

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON Pilot Devices Technical data UL General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder

More information

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22) .6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial

More information

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22) .7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

The ultimate low voltage temporary LED lighting solution

The ultimate low voltage temporary LED lighting solution LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkEx TM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts

More information

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators Ex d GRD-4200 Electronic earthing system - Zone 1, 2, 21, 22 - High quality electronic components - High resistance to corrosion and extreme weather - Safe and reliable over time SIL certified Level 2

More information

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Alligator clip Auxiliary

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected

More information

Control Stations CP.../EFDCN

Control Stations CP.../EFDCN CP.../EFDCN The CP EFDCN range of control stations are based on the features of our CP enclosure, which offers an Ex d IIC mode of protection with or without accessories (push buttons, selector switches,

More information

Control Device System NEC Series ConSig 8040

Control Device System NEC Series ConSig 8040 16113E00 > Enclosure made of glass fibre reinforced polyester resin > Modular design > 3 sizes available > Individual units can be combined into larger units > Standard and customer-specific versions >

More information

P, I, A. Command and control stations Ex e

P, I, A. Command and control stations Ex e P, I, A Command and control stations - Group IIC - Zone 1, 2, 21, 22 - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products - Speed of delivery, designed to customer

More information

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Applications Instrumentation junction boxes are used to run process or remote information to control room. For

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 0 Load and Motor Switchgear Motor Protection ircuitbreakers For use in Zone and Zone Zone and Zone For protection of Ex e and Ex d motors Protects cables and plant equipment Adjustable thermal overcurrent

More information

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5

More information

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400 > As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life

More information