Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Size: px
Start display at page:

Download "Light Fitting for Fluorescent Lamps Series ECOLUX 6600"

Transcription

1 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners E00 The light fittings series 6600 are useable for normal lighting, but also as group or centrally-supplied emergency light fitting. ATEX / IECEx / GOST NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division /52 and 6600/ /56 x x x 6600/52 and 6600/54 x x x 6600/56 x 6600/52 and 6600/54 x 6600/56 x x x x x x x x x x WebCode 6600A Lighting /1

2 Selection table Version Lamps Electronic ballast Order number Weight Number of lamps Lamp wattage W kg ECOLUX channel ECG 6600/ channel ECG 6600/ channel ECG 6600/ channel ECG 6600/ channel ECG 6600/ channel ECG 6600/ Order number supplement Through wiring Standard: without 6600/ Special: with 3 conductors 6600/ Special: with 5 conductors 6600/ Cable entry Standard: M25 x 1.5; 1 cable entry, 6600/ stopping plugs Special: M20 or M 25 in moulded material or metal Specify on order 6600/ Switching off Standard: without 6600/ Special: with switch 8080, 2-pole 6600/ ECG V 1xDC (18 W, 36 W and 58 W; IEC-standard) 6600/ V 1xDC (18 W and 36 W; IEC-standard) 6600/ V 2xDC (17 W, 32 W and 40 W; NEC-standard) 6600/ Terminal strip Special: terminal strip 8184, 4 / 6 mm 2 solid / finely stranded 6600/ Standard: WAGO mm / Number of terminals Standard: with 3 cores; L1 + N + PE 6600/ Special: with 5 cores; L1 + L2 + L3 + N + PE 6600/ Address module Standard: without 6600/ Special: ADR20 ILS 6600/ Note The light fittings are supplied without tubes and mounting accessories. These parts must be ordered separately. Explosion protection Explosion protection Global (IECEx) Gas and dust IECEx BVS X Ex na II T4 Gc Ex tc IIIC T * C Dc oder Ex tb IIIC T * C Db * surface temperature see test certificate Europe (ATEX) Gas Zone 2: DMT 01 E 085 X Zone 2: E II 3 G Ex na IIC T4 Gc Dust Zone 21: DMT 01 ATEX E 086X Zone 22: DMT 01 E 085X Zone 21: E II 2D Ex tb IIIC T * C Db Zone 22: E II 3D Ex tc IIIC T * C Dc * surface temperature see test certificate Certificates and approvals Certificates Other approvals IECEx, ATEX, Brazil (UL do Brasil), Kazakhstan (GOST-K), Russia (GOST-R), USA Canada (FM), Belarus (GOST-B), Taiwan (ITRI) ship approval (GL) /2 Lighting

3 Technical data Electrical data Ballast Power factor cos p Disconnection of the light 6600/ / Lamp start Cold start Cold start Voltage Vac Vac Voltage Vdc Vdc DC during switching on Voltage Vdc Vdc DC during operation Frequency 0 / Hz 0 / Hz Operation of the lamps DC with 1 lamp with 2 lamps Lamps standard IEC IEC Lamp power 18, 36, 58 W 18, 36 W Nominal current 1x18W 85mA 2x18W 170mA 1x36W 160mA 2x36W 320mA 1x58W 250mA 2x58W 500mA cos p ) 0.96 capacitive; additional compensation not required 1x18W mA 2x18W mA 1x36W mA 2x36W mA 6600/ / Lamp start Cold start Cold start Voltage Vac Vac Voltage Vdc Vdc DC during switching on Voltage Vdc Vdc DC during operation Frequency 0 / Hz 0 / Hz Operation of the lamps DC with 2 lamps with 2 lamps Lamps standard IEC ANSI C78.81 Lamp power 18, 36, 58 W 17, 32, 40 W Nominal current On opening the diffuser Faulty lamp 1x18W 75mA 2x18W 150mA 1x36W 150mA 2x36W 300mA 1x58W 240mA 2x58W 480mA 1x17W mA 2x17W mA 1x32W mA 2x32W mA 1x40W mA 2x40W mA optional when opening the fastening mechanism of one of the quick fasteners, voltage to ballast will be switched off all-pole; contacts are positively opening, reconnection when cover and quick fasteners are closed. If lamp is faulty, power supply of lamps is switched off automatically by electronic ballast; when using a 2-channel-ECG power is switched off only to the defective lamp. Lighting /3

4 Technical data Luminous Characteristics Measures for light guidance Luminous intensity distribution Standard Wide beam, reflector painted white. Colour: signal white RAL 9003; prismatic structure for anti-glare in the diffuser sides. Special Additional reflector (easily mounted), broad deep-beam, aluminium anodized and semi-polished E00 Version 1-lamp, without reflector 1-lamp, with reflector Accuracy class acc. to LitG B21 B E00 Ambient conditions Ambient temperature 08259E00 Version 2-lamp, without reflector 2-lamp, with reflector Accuracy class acc. to LitG B21 B31 without trough wiring with trough wiring T a T s max T a T s max V (IEC) 6600/ C + 80 C C + 80 C 6600/ C + 80 C C + 80 C 6600/ C + 80 C C + 80 C V (IEC) 6600/ C + 95 C C + 95 C 6600/ C + 95 C C + 95 C V (IEC) 6600/ C + 70 C C + 70 C 6600/ C + 70 C C + 70 C 6600/ C + 75 C C + 75 C V (NEC) 6600/ C + 85 C 6600/ C + 85 C 6600/ C + 85 C Mechanical data Degree of protection IP66 (IP64 when using breather 8162) Protection class I (with internal PE connection terminal) Material Enclosure Polyester resin, glass fibre reinforced, colour white, similar RAL 9010 Lamp cover Polycarbonate Seal Silicone-gasket foamed into diffuser Quick-acting locks Polyamide, glass fibre reinforced, black / white Assembly parts Polyester resin, glass fibre reinforced, colour white, similar RAL 9010 Cover options Quick fasteners to open with screw-driver; cover hinged for access E00 /4 Lighting

5 Technical data Mounting / installation Mounting Cable glands Connection Standard Special 2 x M8 inserts in housing Mounting grooves in housing to accommodate bracket fitting and ceiling rails for variable light installation. Variable mounting distances of light fittings; see dimension drawings 1 x cable gland 8161, M25 x 1.5, cable dia. range: d mm 2 x stopping plugs 8290, M25 x 1.5 Entry parts in moulded plastic (8161 / 8290): M20 Metal glands: M20; M25; Metal cable gland earthing via metal adapter plates Spring cage terminal connection cross-section: max. 2 x 2.5 mm 2 3 pole (terminal marking: L1 + N + PE) 5 pole (terminal marking: L1 + L2 + L3 + N + PE) Terminal block with screw terminals connection cross-section: max. 2 x 6 mm 2 (solid) max. 2 x 4 mm 2 (flexible) numbers of terminals: 3 pole (terminal marking: L1 + N + PE) 5 pole (terminal marking: L1 + L2 + L3 + N + PE) Installation notes Looping through of There are 2 M25 x 1.5 cable entries on the connection side for looping through of connection cables cable (entry and exit on one side). Through wiring Fittings can be supplied with internal through-wiring. Entry and exit holes for connection cables are positioned on opposite sides. A through-wiring kit can be fitted after manufacture (see accessories). Terminals: See technical data top Wiring cross-section: 2.5 mm 2 for max. 16 A Monitoring module Function Monitoring and switching module for emergency light systems according to VDE 0108: The module is used for the monitoring of individual lights and for the control of network and safety lights. The module offers the following functions: Control of the light (ON / OFF) and function test Up to 20 addresses can be set for each electric circuit by means of a coding switch The operating mode of the lamp (continuous light, stand-by light or activation by means of a switch) is freely programmable Mixed operation within one circuit is possible Input voltage (Input between L+ and N-) Control input (between L and N) Connected power (output to light) Ambient temperature U N U DC U N P 230 (+ 10 % / - 15 %) V AC, 50 Hz V DC 230 (+ 10 % / - 15 %) V AC, 50 Hz W T a (Module) C Dimensions L x W x H = 95 x 40 x 32 mm Lighting /5

6 Accessories and spare parts Designation Figure Description Art. no. Weight Fluorescent lamp 04936E00 Two-pin cap d 26 mm Light colour: universal white 18 W 1350 Im kg W 3350 Im 58 W 5200 Im Diffuser cover Switch 05329E00 for light fitting 18 W for light fitting 36 W for light fitting 58 W Switching element 8080/1-3-L, 2 normally closed contacts Mounting kit for through wiring Reflectors 10809E E E00 For later installation into standard-light fitting DV3, tension clamp terminals 3 x 2.5 mm 2, max. 16 A terminal marking: L1 + N + PE 18 W W W DV5, tension clamp terminals 5 x 2.5 mm 2, max. 16 A terminal marking: L1 + L2 + L3 + N + PE 18 W W W DV3, screw terminals 3 x 2.5 mm 2, max. 16 A terminal marking: L1 + N + PE 18 W W W DV5, screw terminals 5 x 2.5 mm 2, max. 16 A terminal marking: L1 + L2 + L3 + N + PE 18 W W W for later installation, broad deep beam For 1-lamp light fittings 18 W For 1-lamp light fittings 36 W For 1-lamp light fittings 58 W For 2-lamps light fittings18 W For 2-lamps light fittings36 W For 2-lamps light fittings 58 W /6 Lighting

7 Accessories and spare parts Designation Figure Description Art. no. Weight kg Adapter plates for earth continuity when using metal glands; 1 x M20 x piece E00 1 x M25 x piece 1 x NPT 1 / 2 1 piece x NPT 3 / 4 1 piece x M20 x piece 2 x M25 x piece Lamp-holder 2 x NPT 1 / 2 1 piece Lamp holder for two-pin cap lamps G E00 Mounting rail for a variable mounting distance of 1 pair E00 Mounting clamp bracket Mounting bracket mounted on the mounting rail for a variable mounting distance of 1 pair E00 Ring bolts M8, direct mounting in insert nuts, 1 pair Wall-mounting bracket Ceiling mounting bracket 05378E E00 to mount the lamps as side-entry lamps using a tube with a length of 1300 mm, d 42 mm (for pipe clamp R 1 1 / 2 ) for ceiling suspension of the lamp, 1 pair Pipe clamps 05897E00 with mounting rail for a variable mounting distance; Material: stainless steel R 1 1 / 4 (d 42 mm) Mounting set,,grid cable rack 09402E00 R 1 1 / 2 (d 48 mm) R 2 (d 60 mm) for grid cable racks, with a cable diameter of 6 mm; with mounting rail for a variable mounting distance; Material: stainless steel Ceiling and wallmounting bracket 04361E00 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of E00 1 pair Lighting /7

8 Accessories and spare parts Designation Figure Description Art. no. Weight kg Cable gland of moulded material, series E /5-M piece /5-M pieces Stopping plug 04840E /5-M /5-M25-17 of moulded material, series /3-M20 1 piece 8290/3-M /3-M25 x 1,5 8290/3-M25 1 piece 50 pieces 100 pieces 1 pieces 100 pieces Breathing gland 05703E00 for installation in lights; in moulded material; without counter nut Thread: M25 x pc Thread: M25 x pcs /8 Lighting

9 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Light fittings ECOLUX 6600, 18 W, 36 W, 58 W 04824E00 Dimensions Light fitting 18 W 36 W 58 W L L2 1) L3 2) ) Fixed mounting distance 2) Variable mounting distance Pipe clamp 04717E00 Mounting set grid cable rack 04822E E E00 Ceiling- and wall-mounting bracket Ceiling mounting bracket 04823E E E00 Wall mounting bracket for pole-mounting version Ring bolt Mounting clamp bracket Installation accessories We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /9

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600 > 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400 > As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life

More information

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 > For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408 > As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 The single-battery-supplied emergency lamps of the ECOLUX 6608 lighting series are employable as safety lighting

More information

LED Linear Luminaire Series EXLUX 6402

LED Linear Luminaire Series EXLUX 6402 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Sheet-Steel Light Fittings Series 6014 / 6414

Sheet-Steel Light Fittings Series 6014 / 6414 > As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

Linear luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002 > latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6409/1 > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually

More information

Compact Sheet-Steel Light Fittings Series 6114

Compact Sheet-Steel Light Fittings Series 6114 > As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in

More information

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC > For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning

More information

Terminal Boxes Series 8125

Terminal Boxes Series 8125 Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

Sheet Steel Emergency Light Fitting Series 6018

Sheet Steel Emergency Light Fitting Series 6018 > For an operating duration of 1.5 or 3 h > Operating modes Continuous operation Continuous operation with switchable emergency light blocking > Weekly functional test > Total discharge protection and

More information

Load disconnect switch Series 8146/5-V11

Load disconnect switch Series 8146/5-V11 www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation

More information

Floodlight Series 6121

Floodlight Series 6121 www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options

More information

Floodlight Series 6521/4

Floodlight Series 6521/4 > The enclosure made of stainless steel V4A, V2A or powder coated sheet steel is available > Broad or narrow beam reflectors and/or asymmetrical lamp fitting > Series 6521/3 explosion protected floodlight

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact

More information

Terminal Boxes Series 8125

Terminal Boxes Series 8125 Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet > basic enclosure sizes various heights > Fitted according to the customer's requirements

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear

More information

Linear Luminaire for Fluorescent Lamps

Linear Luminaire for Fluorescent Lamps Linear Luminaire for Fluorescent Lamps Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding

More information

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008 Lighting Technology Emergency Light Fittings Can be used in Zone 1 and Zone 2 As pendant or pole-mounting fittings For single- and two-pin fluorescent lamps With electronic ballast and integral emergency

More information

Safety Switches Series 8537

Safety Switches Series 8537 Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part

More information

Tank Inspection Lights Series 6122

Tank Inspection Lights Series 6122 > For halogen lamps 5 W to 100 W > Mounting options tilting hinge mounting bracket flange collar > Corrosion-resistant light metal enclosure > Connection options potted connection lead connection www.stahl.de

More information

Position Switches Series 8060/2

Position Switches Series 8060/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108 Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

Control Buttons / Switches for Panel Mounting Series 8003

Control Buttons / Switches for Panel Mounting Series 8003 www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch > 2 contact elements > Spring clamp

More information

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22 WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge

More information

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked

More information

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone

More information

Tubular Light Fitting with LED Series 6036

Tubular Light Fitting with LED Series 6036 > Extremely robust luminaire design for rough ambient conditions > Very lightweight and vibration resistant LED light fitting > Extremely long service life due to high power LEDs used including driver

More information

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps .4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources

More information

Ex UPS standard Series 8265

Ex UPS standard Series 8265 > Guard battery monitoring according to IEC/EN 60079 et seq. > Adjustable buffer time > Battery function test > Potential-free signal outputs > Maximum efficiency > Increased for reliable triggering of

More information

Control switch/load disconnect switch Series 8008

Control switch/load disconnect switch Series 8008 > s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Sheet-Steel Emergency Light Fitting 09361E00 and 6418 (Zones 2, 21 and 22) emergency light fittings in sheet-steel can be used for safety illumination, especially in spraying and

More information

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc 900/77-80-094-001 158877 For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more compact, space-saving

More information

Linear fluorescent luminaire LED V-CG-S

Linear fluorescent luminaire LED V-CG-S (2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K

More information

Battery Boxes Series 8316

Battery Boxes Series 8316 www.stahl.de > Back-up power supply > Maintenance-free batteries > Low self-discharge > Extremely low gas emissions > Electrolyte-tight > No acid surface coating > Protection against total disch arge >

More information

Linear Luminaire with LED

Linear Luminaire with LED Linear Luminaire with LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3

More information

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , 1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection

More information

Pendant Light Fitting IEC

Pendant Light Fitting IEC Pendant Light Fitting IEC Operating instructions Additional languages www.r-stahl.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3

More information

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22) .6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial

More information

Portable Lamps Series HS6145, HSL145

Portable Lamps Series HS6145, HSL145 www.stahl.de > Portable Lamps Series HS6145 > Comply with requirements of Fire Department standard DIN 14462 > Battery state display > Open circuit monitor > Light intensity 15.000 cd after 4 hours use

More information

Control Device System NEC Series ConSig 8040

Control Device System NEC Series ConSig 8040 16113E00 > Enclosure made of glass fibre reinforced polyester resin > Modular design > 3 sizes available > Individual units can be combined into larger units > Standard and customer-specific versions >

More information

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR) WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,

More information

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22) .7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation

More information

Load and Motor Switches, Load-Break Switches Series 8549

Load and Motor Switches, Load-Break Switches Series 8549 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Pick-off terminal block Auxiliary

More information

Control Buttons Series 8082

Control Buttons Series 8082 www.stahl.de > Contact element with 1 NO contact 1 NC contact, positive opening > Contact material silver-nickel or gold-plated > 9 different actuators Push Mushroom push Selector switch Rotary actuator

More information

Metal Position Switch Series 8074

Metal Position Switch Series 8074 > Dimensions and characteristic values according to EN 50041 > Replaceable contact element in flameproof enclosure > Positive opening contacts > Wide range of actuators > All actuators can be displaced

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,

More information

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components EXENC-L - Zone 2, Zone 21-22 - Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components Resin body reinforced polyester Fixing Brackets Transparent hood

More information

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection

More information

K: bracket type. L: pole type

K: bracket type. L: pole type Lighting Technology Catalogue number logic B0091-0 -0 0 0 Pendant Light Fittings BDD91 Series Explosion-proof Light Fittings Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2

More information

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:

More information

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: alligator clip auxiliary

More information

Linear fittings EVDL LED fitting - zones 21, & 22

Linear fittings EVDL LED fitting - zones 21, & 22 ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected

More information

EXEL-L. Detail of the internal side. Transparent polycarbonate

EXEL-L. Detail of the internal side. Transparent polycarbonate EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin

More information

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific) 4 Remote I/O Series 86 078E00 Series 86 enclosures of glass-fibre reinforced polyester resin or of high grade steel are used in larger control stations and control station combinations. Special sizes are

More information

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVNL LED fitting - zones 2, & 22 65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress

More information

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety : : Applications Can be installed in hazardous areas designated as Zone 1, 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5

More information

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Alligator clip Auxiliary

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC

More information

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Zone & & II GD IP66/67 IK0 Applications: Can be installed in hazardous

More information

Terminal Boxes Series 8252/1

Terminal Boxes Series 8252/1 www.stahl.de > Ex d enclosure made of saltwater-resistant, copper-free aluminium cast alloy > Powder coated to RAL 7032 > Available in 3 different sizes > With DIN rail for standard terminals > Enclosure

More information

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety 4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected

More information

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22 Applications Can be installed in hazardous areas designated as Zone 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

Easy and safe installation

Easy and safe installation ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield

More information

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22 Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance

More information

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22 ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & 22 59 EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components

More information

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A .1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility

More information

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22) .15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent

More information