1 Industrial & azardous Area Electrical Equipment

2 Abtech has been supplying electrical connec on products to hazardous and industrial markets since the 1970 s. Our range includes hazardous area ligh ng, stainless steel and GRP junc on boxes, high voltage enclosures, local controls, cable glands and connec on accessories. Based in Sheffield UK, a city synonymous with quality stainless steel manufacturing, Abtech also has sales support and manufacturing facili es in Germany, Korea, Singapore and ouston USA. Abtech holds ISO 9001:2008 accredita on as well as a number of third party approvals including Lloyds Register Type Approval.

3 Contents Terminal Enclosures 2 Special Enclosure Solu ons 5 MV & V Enclosures 6 Control Sta ons 9 azardous Area Ligh ng 10 Cable Glands 12 1

4 ENCLOSURES BPG The BPG terminal enclosure is manufactured in glass reinforced polyester (GRP). This material is highly resistant to hydrocarbons and other industrial compounds, providing a high level of mechanical strength. It is also suitable for use in LSZ (low smoke zero halogen) applica ons. Glass reinforced polyester: available in grey or black (an sta c) -65 C to +130 C Fire resistant to IEC 331 & BS EN Impact resistant > 7 Nm UV resistant Zone Ex ia Ex ib Ex ec Ex nr EX t BPG BPG BPG BPG BPG BPG BPG BPG BPG BPG BPG BPG BPG BPG BPG BPG BPG BPGA The BPGA range comprises three types of pre-assembled enclosure in two different sizes. These are supplied complete with terminals, links, earthing and predrilled M20 threaded entries. BPGA enclosures are ideal for use as ligh ng, power and instrument junc on boxes. Glass reinforced polyester: available in grey or black (an sta c) -65 C to +130 C Impact resistant > 7 Nm UV Resistant Supplied with SAK or U terminals Ex e apparatus cer fied ual labelled ATEX & IECEx T5/T6 BPG6A BPG6A BPG8A Terminals Power Ra ng () BPG6A120 6 x SAK BPG6A125 6 x U BPG8A x SAK

5 SX The SX range of enclosures are manufactured in either stainless or mild steel. Various sizes are available in depths of 140 or 200mm or 300mm. The majority of the range can be fi ed with removable gland plates on any or all of the four sides. Electro-polished and painted finishes are available. /68 Steel: 316L (1.404) Stainless (SSX) or Mild (MSX) -50 C to +175 C Impact resistant > 10 Nm Corrosion resistant Gland plates can be fi ed to any or all four sides (SX66 and above) Zone Ex ia Ex ib Ex op is Ex op pr Ex ec Ex t SX SX SX SX /200 SX /200 SX /200 SX /200 SX /200 SX /200 SX /200 SX /200 SX6 * /200 SX7 * /200 SX8 * /200 * also available 300mm ENCLOSURES Fire Resistant P120 Grey glass reinforced polyester Increased fire survivability for safety cri cal electronic circuits P120 (120 minutes) in accordance with BS EN and BS Tested in accordance with IEC 311 All fixings 316 stainless steel BPG6F BPG8F Terminals BPG6F way up to 6mm 2 BPG8F way up to 6mm 2 BPGF The BPGF is a fire resistant range comprised of two enclosure sizes, pre-assembled with Abtech s ceramic terminal block. It is supplied complete with four M20 threaded entries, two stainless steel plugs and two transit plugs. In addi on to the BPGF preassembled range, Abtech also supplies a range of fire rated enclosures in GRP and stainless steel. These can be populated with rail mounted terminals or fi ed with the ATB 8 and 12 way ceramic terminal blocks. IMPORTANT Please consider cable selec on when specifying fire resistant electrical systems. 3

6 ENCLOSURES IP66 esigned to house electrical apparatus safely within hazardous areas -20 C to +60 C Variable entry combina ons on any of the 4 ver cal sides SS SS SS434-A SS434-B SS SS445-A SS The SS is a marine grade stainless steel flameproof enclosure suitable for use in Zone 1 and 21 hazardous areas. Any size of enclosure is possible as long as each dimension falls within the range of smallest to largest size as shown. Ex db Ex td SS SS SS556-A SS556-B SS SS SS SS Internal dimensions only Other sizes available on request NAUTILUS The Nau lus combines hazardous area cer fica on with an unparalleled level of ingress protec on. Primarily designed for submersible applica ons, it is IP68 cer fied to 100 metres for five days. IP68 Submersible terminal enclosure -50 C to +55 C Ingress protec on to IP68 (100m for 5 days, 50m for 14 days to EN60529) Variable entry combina ons on any of the 4 ver cal sides Ex ib Ex ia Ex tb Ex ta NAUT NAUT NAUT NAUT3A NAUT NAUT NAUT NAUT7A NAUT7B NAUT NAUT NAUT NAUT Internal dimensions only Other sizes available on request 4

7 VisEx The VisEx is a flameproof instrumenta on housing suitable for various POE (Power Over Ethernet), vision and instrumenta on systems where opera on in a hazardous area is required. -60 C to +65 C Custom moun ng brackets Superior environmental protec on Ex d EX tb VISEX116A4 VISEX216A4 VISEX120A4 VISEX220A4 VISEX116120A4 Entries 1 x M16 2 x M16 1 x M20 2 x M20 1 x M16 1 x M20 Max power ra ng 8 (T6) 47 (T4) 8 (T6) 47 (T4) 8 (T6) 47 (T4) 8 (T6) 47 (T4) 8 (T6) 47 (T4) SPECIAL ENCLOSURE SOLUTIONS LR The LR Box is designed to allow MV cables to enter and exit at 90 to each other. Supplied complete with three gland plates, its unique design can be modified by the installer to allow either le hand or right hand cable connec ons. Flexible on-site installa on Max voltage 3.3kV Max current 1,250A Overload current 1,845A for 10 seconds -50 C to +55 C (T3) -50 C to +40 C (T4) TS-01 deluge tested Suitable for extreme low temperature applica ons Ex tb LR52 L LR52 R LR73 L LR73 R

8 MEIUM & IG VOLTAGE ENCLOSURES MJB The MJB range provides a simple, low cost but effec ve solu on for the connec on of high voltage cables. Used primarily for join ng cables or as a connec on box, the MJB is suitable for up to 4 phase connec ons (top and bo om) and a maximum of 8.3kV. ABJB & VJB Up to 8.3kV -20 C to +40 C standard -50 C to +65 C op on IP66 to EN60529 TS-01 deluge tested 180 in and out cable connec on Suitable for low temperature applica ons Range of paint finishes available Ex t Up to 15kV ABJB up to 15kV, VJB up to 11kV Fault rated 45kA for 0.2 seconds IP66 to EN C to +40 C or -50 C to +55 C TS-01 deluge tested Suitable for low temperature applica ons Li -off, pad-lockable cover with heavy duty machined hinges Range of paint finishes available MJB MJB MJB MJB MJB MJB MJB MJB VJB VJB VJB ABJB ABJB ABJB The latest in the high voltage range offering enhanced flexibility over the choice of cables, entries and termina ons. The VJB can accept up to 4 phase connec ons either straight through or bo om entry only. The unit can accommodate up to three connec ons per phase. Ex s Ex tb 6

9 AB/V 125 TFJB Up to 15kV Unique termina on solu on to combine op cal fibres and power cable supplies in a single enclosure IP66 to EN60529 Fault rated 45kA for 0.2 seconds TS-01 deluge tested Ex s Ex op is Up to 36kV IP66 to EN60529 Maximum current 312A Three phase connec ons via bo om entry only One connector per phase in/ out (standard configura on) TS-01 deluge tested Ex tb VJB1253 L VJB1254 L ABJB1253 R ABJB1254 R TFJB 83 (0-2) MEIUM & IG VOLTAGE ENCLOSURES Up to 45kV IP66 to EN60529 Three phase connec ons either straight through or bo om entry One connector per phase in/ out (standard configura on) TS-01 deluge tested Li -off double doors with heavy duty machined hinges 4TJB TJB Ex tb 7

10 MEIUM & IG VOLTAGE ENCLOSURES BUSBAR BOX This 11kV enclosure is designed to safely carry medium voltage supplies with extreme current loadings in Zone 1 hazardous areas. Accommodates large diameter cables, suitable for connectors up to 1000mm 2. Up to 11kV Up to 3,200A per phase Connect three phases + neutral and up to six conduc ons per phase Fault rated 90kA for 1 second -40 C to +40 C or -40 C to +60 C (see cer ficate) IP66 to EN60529 TS-01 deluge tested Ex tb Up to 6.6kV Plas c UTR Laminate GP03 Grade 1494 Available in three, four and six way configura ons Linkable in pairs or mul ples -40 C to +130 C BBB TATEMV TATEMV TATEMV TATEMV3T TATEMV4T TATEMV6T MV The MV medium voltage terminal is a component cer fied device that simplifies the connec on of 4.4 to 6.6kV electrical supplies. Ex eb Max (kv) Max (A) Max ays TATEMV TATEMV TATEMV TATEMV3T It can be used with any ATEX or IECEx Zone 1 cer fied enclosure. TATEMV4T TATEMV6T

11 IP66 PCS ABCS SXCS Corrosion resistant polyamide Universal contact block mounted direct to integral moulded rail Typical ambient temperature range -40 C to +40 C Linkable enclosure modules Coding Ex de IIC T6 Ex e II T6 Ex t A21 IP66 Carbon loaded GRP azardous and Industrial areas Typical ambient temperature range -40 C to +55 C Coding Ex db eb IIC T* Gb Ex db eb mb IIC T* Gb Ex db IIIC T*C b Terminals irect termina on as standard, 2.5/4mm 2 terminals available IP66 316L stainless steel azardous and Industrial areas Typical ambient temperature range -40 C to +55 C Coding Ex db eb IIC T* Gb Ex db eb mb IIC T* Gb Ex db IIIC T*C b Terminals irect termina on as standard, 2.5/4mm 2 terminals available CONTROL STATIONS Available Operator, Ammeter and Terminal Types Common to PCS, ABCS and SXCS Ranges available with 1NC/1NO, 2NC or 2NO contacts Push Bu on Emergency Stop Key Release Mushroom ead Indicator Lamp Illuminated Push Bu on Selector Switch - Small andle Selector Switch - Large andle Ammeter Momentary, single or double push. Coloured/marked inserts are required Push-Pull or twist to release. Red/yellow mushroom head Colour: red Momentary. Colour: black, green and red Red/green/yellow/blue or white available. Ex e and Exiiiversions Red/green/yellow/blue or white available. Available with 1NC or 1NO contacts 39mm diameter; 2, 3 or 4 posi on; self-lock or self-reset; 2-pole contact configura ons and label inserts to suit applica on 60mm diameter; 2, 3 or 4 posi on; self-lock or self-reset; 2-pole contact configura ons and label inserts to suit applica on irect measuring with x2 overload scale (max scale: 0-15A/30A); 1A or 5A current transformer with x2 or x5 overload scale (max scale: 0-600A/3000A) 9

12 AZAROUS AREA LIGTING Simple and quick lamp replacement, single tool opera on, no need to remove cover Internal flame path removes the need for rou ne physical inspec on ark Sky asymmetric design reduces light pollu on and glare Ignitor in lamp body allows op onal remote gear box and reduced weight on pole II 2 G Ex de IIB Alpha The Alpha is a highly efficient Ex de asymmetric floodlight designed for use in Zone 1 and 21 hazardous areas. APC Based on proven BPG enclosure range Reduces carbon emissions and running costs by switching off ligh ng automa cally when a specific light level is reached Standard switching level is 70 lux The APC provides controlled switching of ligh ng in hazardous areas without the need for major rewiring of exis ng circuits. Built in delay of 25 seconds to prevent nuisance switching II 2 G Ex e mb IIC T6 Gb, Ex tb IIIC T80 C b The Junos is a linear LE luminaire designed as a replacement for Zone 1 T8 surface mounted fluorescents. Junos Low glare design, even uniformity of light Complete stainless steel construc on ensures maximum opera onal life Emergency version with ba ery status/ fault condi on indicator and automa c self-tes ng Fixing centres to match popular 18 and 36 fluorescent types 5 year complete system warranty II 2 G Ex eb ib qb IIB Gb IP22 Exodus Nimbus Gamma The Exodus bulkhead is designed for use in heavy industrial and marine environments. Five year complete system warranty. The Nimbus is a low-profile LE panel which provides significant weight and energy savings over a tradi onal recessed fluorescent. The Gamma is a high output LE floodlight for use in Zone 1 and 2, 21 and 22 hazardous areas. 5 year complete system warranty. Compact design ideal for building perimeter, walkway or stairwell ligh ng Manufactured in LM24 aluminium alloy, powder coated for corrosion resistance Illuminated using LE technology Accommodates any fire exit sign to ISO 7010 (300 x 150mm) 20, 5,700 lumen output II 2G Ex eb ib qb IIB Gb Excellent uniformity and colour rendering Range of sizes all with built in dimming (push to dim) Emergency version with ba ery status/fault condi on indicator automa c self-tes ng Plug and socket connec on between panel and driver for easy installa on 5 year complete system warranty Ex ib IIB T4 Gb, Ex eb [ib Gb] qb IIB T4 Gb igh performance LE module providing uniform and crisp white light Zone 1-72/10,000 lumens Zone 2-96/13,600 lumens Marine grade stainless steel construc on Control gear with thermal cut-off II G, Ex eb ib op is qb IIB T* Gb, Ex tb IIC T* 0 C b Ex na IIC T* Gc, Ex tb IIIC T* C b, Ex tc IIIC T* C c 10 Refer to individual Product ata Sheets for full specifica ons, T ra ng and ambient range

13 Avena Marine grade stainless steel construc on Two sizes dependent on wa age Efficient op cal design and five posi on adjustment for op mal horizontal distribu on Internal control gear suitable for both high pressure sodium and metal halide lamps Timed ignitor as standard Ex nr IIC T* Gc, Ex tc IIIC T135 C c IP65 The Avena is a Zone 2 & 22 road lantern for use in marine and heavy industrial environments such as roads, walkways and perimeters. Gamma LG The Gamma LG is a low glare luminaire that can be used as either floodlight or lowbay. Its design minimises the effects of disability glare. Patented light guide technology reduces visual discomfort for safe working Marine grade stainless steel construc on with built in junc on box for simple installa on Control gear with thermal cut-off protec on to maintain LE life 5 year complete system warranty Ex na IIC T* Gc, Ex tb IIIC T* C b and Ex tc IIIC T* C c The STR1 is an LE road lantern designed for use in Zone 2 and 22 hazardous areas. It provides excellent horizontal distribu on. STR1 igh performance op cal design for maximum spacing between poles Low windage design suitable for moun ng on poles 7-10m Maintenance free LE design 120, 12,348 lumens 5 year complete system warranty Ex nr IIC T* Gc, Ex tc IIIC T100 C c IP66 AZAROUS AREA LIGTING elta The elta Ex nr asymmetric floodlight is designed for use in Zone 2 & 22 hazardous areas vus The vus Ex nr symmetric floodlight is designed for use in Zone 2 & 22 hazardous areas. Op mus The Op mus wellglass is for use in Zone 2 & 22 hazardous areas. For maximum flexibility a range of moun ng styles are available. ark Sky asymmetric design reduces light pollu on and glare Quick access lamp chamber reduces maintenance me, no need to open cover Marine grade stainless steel construc on Op onal remote control gear box for weight saving when pole or mast moun ng Ex nr IIC T* Gc, Ex tc IIIC T C c Compact design with internal control gear Quick access lamp chamber reduces maintenance me, no need to open cover Timed ignitor supplied as standard Ex nr IIC T* Gc, Ex tc IIIC T C c Flexible body layout capable of accep ng a wide range of lamp types Lightweight aluminium construc on inged base/body combina on for easy installa on Versa le range of moun ng op ons Ex nr IIC T* Gc, Ex tc IIIC T C c Refer to individual Product ata Sheets for full specifica ons, T ra ng and ambient range 11

14 CABLE GLANS AAG Range ABG Range Nickel plated brass or stainless steel Armoured Gland - ouble Compression Applica ons Indoor or outdoor use Single wire armour (), wire braided (X), steel tape (Z), screened flexible wire braid Temperature Range -60 C to +100 C Flameproof Ex d, Increased Safety Ex e and ust Ex t Interna onal Approvals Armoured Barrier Gland - Compound Nickel plated brass or stainless steel Applica ons Indoor or outdoor use Single wire armour (); wire braided (X); screened flexible wire braid Temperature Range -60 C to +100 C Flameproof Ex d, Increased Safety Ex e and ust Ex t Interna onal Approvals AG Range ASG Range Nickel plated brass or stainless steel n-armoured Gland - ouble Compression Applica ons Two independent seals, a flameproof seal on the inner or outer sheath with a 2 nd IP seal on the outer n-armoured elastometer and plas c cables Temperature Range -60 C to +100 C Flameproof Ex d, Increased Safety Ex e and ust Ex t Nickel plated brass or stainless steel Applica ons Provides a seal on the outer cable sheath n-armoured elastometer and plas c cables Temperature Range -60 C to +100 C Suitable for sealing outer cable sheath Flameproof Ex d, increased safety Ex e and Ex t ust Interna onal Approvals n-armoured Gland Interna onal Approvals 12 AAPTERS, Adapters, Reducers REUCERS and AN Stopping STOPPING Plugs PLUGS A range range of of cable thread glands, adapters, adaptors, reducers reducers and stopping and stopping plugs is plugs available manufactured manufactured from from brass, nickel-plated nickel-plated brass brass or or stainless stainless steel steel for for use use in in hazardous hazardous areas areas Zone Zone 1 & 2, 2, & ACCESSORIES ACCESSORIES: Also available is an extensive range of associated Also accessories available including is and extensive earth tags, range sealing of associated washers, serrated accessories washers, including earth Interna onal tags, sealing washers, serrated locknuts and washers, PVC shrouds locknuts - and see main PVC shrouds catalogue - see for main further catalogue details. for further details Approvals

15

16 Abtech Limited Newhall Road Lower on Valley Sheffield S9 2QJ United Kingdom t: +44 (0) f: +44 (0) e: w: abtech.eu

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13 Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.

More information

ABCS GRP Control Stations

ABCS GRP Control Stations ABCS GRP Control Stations Application Industrial and Hazardous areas IP65/66 Protection Degree IP66 (IP65 when fitted with an ammeter) Certification ATEX & IECEx Ex e II T4 or Ex ed IIC T4 Material Glass

More information

The safety you rely on.

The safety you rely on. Cable Glands Global Solutions Catalogue The safety you rely on. Cable Glands & Accessories Global Solutions Introducing Crouse-Hinds by Eaton The leader in electrical products for hazardous, industrial

More information

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22) .6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial

More information

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22) .7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation

More information

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22 WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge

More information

Glass Reinforced Polyester Enclosures

Glass Reinforced Polyester Enclosures 42 The GRP range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,

More information

ABG Cable Glands Installation Procedure

ABG Cable Glands Installation Procedure ABG Cable Glands Installation Procedure ABG Cable Gland Range Baseefa 16ATEX0004X IECEx BAS 16.0011X Installation, Operation and Maintenance Instructions Material: Brass/ Brass with Nickel plated and Stainless

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Linear luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002 > latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVNL LED fitting - zones 2, & 22 65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Capri ADE 6F - for Armoured Cable

Capri ADE 6F - for Armoured Cable Capri ADE 6F - for Armoured Cable Technical Specification Suitable for the following cable types Steel wire armoured cable (SWA) Steel wire braided cable (SWB) Steel tape armoured cable (STA) Braided marine

More information

Linear fittings EVDL LED fitting - zones 21, & 22

Linear fittings EVDL LED fitting - zones 21, & 22 ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield

More information

Armoured / Un-armoured Cable Gland

Armoured / Un-armoured Cable Gland Armoured / Un-armoured Application These cable glands are used ; suited to armoured/un-armoured cables used mainly in areas where British Standards apply. particularly suited to Steel Wire Armoured. compliance

More information

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22 ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & 22 59 EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components

More information

Load disconnect switch Series 8146/5-V11

Load disconnect switch Series 8146/5-V11 www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation

More information

The invisible power and data connector for wearables in hos le environments

The invisible power and data connector for wearables in hos le environments Connectors mag Net The invisible power and data connector for wearables in hos le environments For wearable electronic systems that require invisible power and data connec vity, mag Net is a ground breaking

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless

More information

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22 Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation

More information

Linear fittings EVN Fluorescent fitting - zones 2 & 22

Linear fittings EVN Fluorescent fitting - zones 2 & 22 LIEAR FITTIGS - EV FLUORESCET FITTIG - ZOES 2 & 22 71 EV Fluorescent fitting - zones 2 & 22 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray

More information

EX-D ENCLOSURES AND DISTRIBUTIONS

EX-D ENCLOSURES AND DISTRIBUTIONS EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected

More information

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS Z A H LO C ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS BASIC CATALOG NUMBERS HKHPBMMSS1 HKHPBMMTC1 HKHPBILLMM1 HKHPBMMMR1 HKHPBMMMB1 HKHPBMMMG1 HKHDBLPBMMGR1 HKHPBPMTMR1 HKHPBPMTMB1 HKHPBPMTMG1 HKHPBTMTMR1

More information

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps .4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency

More information

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22) .5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust

More information

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC > For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder

More information

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6409/1 > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually

More information

ADE 6F ADE 6F. page 46

ADE 6F ADE 6F. page 46 ADE 6F 6 F U N C T I O N S : D O U B L E C L A M P I N G > For armoured cable > IP68 > Compliance > EX 60079-0 2009 Performance > Nickel plated brass standard finishing > Optional : stainless steel, aluminium

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

Floodlight Series 6121

Floodlight Series 6121 www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS Ex d Ring Enclosure Ex e Terminal Boxes Hollow Option Ambient Temperature Maximum Throughput Current Protection Mounting (increased range available) 20 rpm (higher on request) 770V ac 1166 Amps In any

More information

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A .1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected

More information

Leading the way in hazardous areas Features EATON

Leading the way in hazardous areas Features EATON .2 Ex-escape sign luminaires EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22 Moulded plastic version with LED-technique Leading the way in hazardous areas The EXIT series of explosionprotected

More information

defender-s NJZ-FEL-B Series Hazardous Locations&Explosive Atmospheres Zone1&2, Zone21&22 II 2G Ex d IIB T5 Gb II2D Ex tb IIIC 95 Max Db IP 66

defender-s NJZ-FEL-B Series Hazardous Locations&Explosive Atmospheres Zone1&2, Zone21&22 II 2G Ex d IIB T5 Gb II2D Ex tb IIIC 95 Max Db IP 66 defender-s NJZ-FEL-B Series Hazardous Locations&Explosive Atmospheres Zone1&2, Zone21&22 II 2G Ex d IIB T5 Gb II2D Ex tb IIIC 95 Max Db IP 66 features Defender-S explosion-proof light uses simple profile,

More information

LED Linear Luminaire Series EXLUX 6402

LED Linear Luminaire Series EXLUX 6402 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600 > 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600

More information

Control Units Ex e Glass Fiber Reinforced Polyester

Control Units Ex e Glass Fiber Reinforced Polyester Features Assembly Glass fiber reinforced polyester (GRP) enclosures Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex de, Ex ib and Ex tb Up to 4 operators per control unit, base-mounted contact

More information

New products Ex Equipment 2015

New products Ex Equipment 2015 New products Ex Equipment 2015 ROSE Systemtechnik GmbH ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany, in 199 and is today one of the world s leading and innovative providers of industrial

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable. ppleton s TX product line includes a wide selection of both Increased Safety and lameproof cable glands for use with unarmored and armored cable. ppleton's TX cable glands are available in a wide range

More information

The ultimate low voltage temporary LED lighting solution

The ultimate low voltage temporary LED lighting solution LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkExTM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts

More information

M-0. M-0... series control, monitoring and signalling devices. Ex e

M-0. M-0... series control, monitoring and signalling devices. Ex e M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere

More information

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof Ex de IIB Type PB Ex de IIC Type PC Ex de IIB Type PL Low Temperature Rating Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIB (PB and PL) T4 to T1 Ex td A21 T130 C to T378 C IP66 (Type

More information

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Applications Instrumentation junction boxes are used to run process or remote information to control room. For

More information

EXEL-L. Detail of the internal side. Transparent polycarbonate

EXEL-L. Detail of the internal side. Transparent polycarbonate EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin

More information

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen Applications Designed for large area lighting in industrial outdoor and indoor hazardous areas. Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas industry. In locations such as: refineries,

More information

Cable Glands - American Series - NEC/IEC

Cable Glands - American Series - NEC/IEC Cable Glands - 103 American Series - NEC/IEC 104 Cable Glands Explosion Proof & General Purpose Cable Gland/Connector Type 711 1 2 3 1 Unique Rear Sealing System This arrangement offers IP66, IP67, IP68

More information

LED STREET LIGHTS Rev./150617/AL

LED STREET LIGHTS Rev./150617/AL Rev./150617/AL Overview An elegant design with LED module combined with highly efficient PHILIPS LUXEON T LED luminous source and a highly reliable Mean Well driver series HLG. The H2-Series LED street

More information

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Linear fittings Fluorescent fitting EVN - Zones 2 & 22 Fluorescent fitting Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

GEAR PUMP SYSTEMS PROCESS & CHEMICAL FEED EQUIPMENT

GEAR PUMP SYSTEMS PROCESS & CHEMICAL FEED EQUIPMENT PROCESS & CHEMICAL FEED EQUIPMENT Oil & Gas Power Genera on Chemical Processing Mining Pulp and Paper Water Resources Pharmaceu cal GEAR PUMP SYSTEMS USA +1.251.662.1250 phone +1.251.662.8250 fax Gear

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

Floodlight Series 6521/4

Floodlight Series 6521/4 > The enclosure made of stainless steel V4A, V2A or powder coated sheet steel is available > Broad or narrow beam reflectors and/or asymmetrical lamp fitting > Series 6521/3 explosion protected floodlight

More information

Linear fluorescent luminaire LED V-CG-S

Linear fluorescent luminaire LED V-CG-S (2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K

More information

PY, SPY; FSQC, FP; EPC; AP

PY, SPY; FSQC, FP; EPC; AP Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester

More information

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel ADE 4F 4 F U N C T I O N S : D O U B L E > For armoured cable > IP68 > Compliance > EX 60079-0 2009 Performance > Nickel plated brass and stainless steel > Optional : aluminium and bronze raw material

More information

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR) WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,

More information

HAZ AREA LIGHTING. Product Brochure. Design to Manufacture FOR HAZARDOUS AREAS. Engineering Solutions. An A-Belco Group Company

HAZ AREA LIGHTING. Product Brochure. Design to Manufacture FOR HAZARDOUS AREAS. Engineering Solutions. An A-Belco Group Company HAZ AREA LIGHTING FOR HAZARDOUS AREAS Product Brochure Engineering Solutions Design to Manufacture An A-Belco Group Company The Hadar Lighting Range Designed and manufactured in the UK by A-Belco Hazardous

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Linear fittings EVTL Weatherproof LED fitting - Industrial applications 89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted

More information

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

HKH Series. HAZCON Controls for Harsh and Hazardous Environments HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2 Features Wide or narrow beam Ex e integral junction box Flat or pole mounting Supplied with lamp installed Including accessories (cable gland & plug) Supplied with offshore grade paint Manufactured from

More information

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , 1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

The ultimate low voltage temporary LED lighting solution

The ultimate low voltage temporary LED lighting solution LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkEx TM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts

More information

FHL. Ex d. Body in aluminium

FHL. Ex d. Body in aluminium Ex d FHL Body in aluminium - Zones 1, 2, 21, 22 - Integrated electronic ballast - Power supply 24 V DC - Compact 24/36 W fluorescent tube - Degree of protection IP66 Guard in stainless steel Polycarbonate

More information

EX-REPAIR AND MAINTENANCE RECEPTACLES

EX-REPAIR AND MAINTENANCE RECEPTACLES EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand

More information

Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications.

Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications. Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications. Intrinsically Safe Explained Ha ardous Area Classification Zone 0, Zone, Zone This diagram shows

More information

ellk 92 LED Light Fittings

ellk 92 LED Light Fittings CEAG Products Ex-Solutions LED Lighting ellk 92 LED Light Fittings Linear light fitting series with new LED module for hazardous areas Zone 1, 2, 21 and 22 www.crouse-hinds.de EATON 1.2.1 Ex-LED-Linear

More information

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings.  EATON 1.3.1 CEAG Products Main Catalogue Part 1 Chapter Emergency and safety light fittings www.crouse-hinds.de EATON 1..1 .1..2.1..2 EATON'S CROUSE-HINDS BUSINESS EATON Ex-Signal- and Rettungszeichenleuchten www.crouse-hinds.de

More information

GRATIS - FREE OF CHARGE:

GRATIS - FREE OF CHARGE: Rel. 20150206 Applica ons: Primary standard for defining the pressure scale in a range up to 1200 bar hydraulic Reference instrument for factory and calibra on laboratories for the tes ng, adjustment and

More information

PROTECTA III. Construction Tough glass reinforced polyester body

PROTECTA III. Construction Tough glass reinforced polyester body PROTECTA III 20 Construction Tough glass reinforced polyester body Polycarbonate diffuser with high resistance to UV and stress cracking Robust hinges and multipoint compressive clamping of diffuser closure

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning

More information

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Ex de RLFE Mounting bracket - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Stainless steel guard Ex e terminal housing B.1 ED.2018

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control

More information

Wolflite XT Rechargeable LED Handlamp

Wolflite XT Rechargeable LED Handlamp Wolflite XT Rechargeable LED Handlamp Zones: 0, 1, 2, 20, 21 and 22 Product Overview Features & Benefits The Wolflite XT Rechargeable Handlamp exploits advanced technology to deliver excellent performance,

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

PERMANENT MAGNET PUMPING SYSTEMS

PERMANENT MAGNET PUMPING SYSTEMS PERMANENT MAGNET PUMPING SYSTEMS SECTION 5 Ver.01-2018 INTRODUCTION Magne c Pumping Solu ons offers the MAG LINE of Cables that is suitable for the installa on with ESP systems in oil, water and gas producing

More information

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22 Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance

More information

LDW-HK. Deadweight Tester / Pressure Balance Hydraulic & Compact Design

LDW-HK. Deadweight Tester / Pressure Balance Hydraulic & Compact Design Deadweight Tester / Pressure Balance LDW-HK Rel. 20120820 Applica ons: Primary standard for defining the pressure scale in a range up to 1200 bar hydraulic Reference instrument for factory and calibra

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:

More information

Amphenol Cable Glands and Cord Grips Amphenol

Amphenol Cable Glands and Cord Grips Amphenol Amphenol Cable Glands and Cord Grips 12-055-1 Amphenol Table of Contents Page Number Introduction 1 Amphenol Cable Glands 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated

More information

EX CABLE GLANDS FOR HAZARDOUS AREAS ATEX & IECEX. Zones 1, 2, 21 and 22.

EX CABLE GLANDS FOR HAZARDOUS AREAS ATEX & IECEX. Zones 1, 2, 21 and 22. EX CABLE GLANDS FOR HAZARDOUS AREAS & IECEX Zones, 2, 2 and 22 CABLE GLANDS EX D/E 4 CABLE GLANDS UNARMOURED EX D IP66 - IP68 5 CABLE GLANDS UNARMOURED EX E IP66 - IP68 5 CABLE GLANDS UNARMOURED EX D/E

More information

Position Switches Series 8060/2

Position Switches Series 8060/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Linear fittings EVTL Weatherproof LED fitting - Industrial applications 89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted

More information

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist

More information

Valve Lockouts. Valve lockouts are available to suit all types of valve including ball valve, gate valve, globe valve and plug valve.

Valve Lockouts. Valve lockouts are available to suit all types of valve including ball valve, gate valve, globe valve and plug valve. Valve lockouts are available to suit all types of valve including ball valve, gate valve, globe valve and plug valve. A well fi ed valve lockout will provide protec on against accidental or unauthorised

More information