Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22
|
|
- Marshall Maxwell
- 5 years ago
- Views:
Transcription
1 ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components mounted on hinged and removable gear tray for easy maintenance Double central locking for ingress protection Automatic switch off on opening Includes accessories (cable gland, plugs & fixing brackets) EVS fluorescent fitting with easy disconnect Approvals & certifications Exde G IIC GROUP II Extb IIIC D 2 IP 66 IK 2 22 Specifications Main body constructed of glass-reinforced polyester for high impact strength UV protected polycarbonate diffuser to resist harsh environments Electronic ballast Vac / 5-6Hz EOL (End of life) the ballast prevents the lamp cap at the end of lamp life cycle from overheating Instant start Wiring configuration: 5 wires 3x entries M2 2x versions (type: EM version 3h battery duration or EMA with 3h with automatic test and blackstart capabilities) Approved to: ATEX Directive (24/34/EU) EMC Directive (24/3/EU) Standards EN 679-: General requirements EN 679-: Flameproof enclosure d EN 679-3: Enclosure t EN 679-7: Increased safety e LCIE ATEX 365X IEC Ex LCI.53X II 2 G Ex de IIC T4 Gb for -4 C to +6 C or Ex de IIC T5 Gb for -4 C to +35 C II 2 D Ex tb IIIC T85 C Db IP66 for -4 C to +6 C EN 555: Conducted emission test and radiated emission test EN 6547: CEM immunity EN 6-3-2: Harmonic current Emissions Class C EN 6-3-3: Limitation of voltage changes and flickers Easy disconnect to remove gear tray Low voltage Directive (24/35/EU) EN 6598-: Luminaire general requirements and tests, including dielectric strength and isolation resistance 2 UV protected polycarbonate diffuser Glow wire test: Operating temperature: 96oC -2 C to +55oC EVS, - C to +5oC EVS EM & EVS EMA 2 IP test: Impact protection index: IEC 6529: IP66 IEC 62262: IK
2 6 ABB DTS LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 EVS fluorescent fitting 5 wires Suitable for use in Zones, 2, 2, 22 Dimensions 2 x M8 hole 2mm depth C B 37 mm EVS 5 wires: Equipped with cable gland & 2 plugs A 7 mm Type For Dimensions mm Wiring Light Current A non armored cable armored cable Configuration Rating 23V A B C EVS2- EVS2-D 5 wires* x EVS4- EVS4-D 5 wires* x EVS65- EVS65-D 5 wires* x EVS22- EVS22-D 5 wires* 2 x EVS24- EVS24-D 5 wires* 2 x EVS265- EVS265-D 5 wires* 2 x Weight kg EVS 5 wires through: Equipped with 2 cable glands & plug EVS2-B EVS2-E 5 wires through** x EVS4-B EVS4-E 5 wires through** x EVS65-B EVS65-E 5 wires through** x EVS22-B EVS22-E 5 wires through** 2 x EVS24-B EVS24-E 5 wires through** 2 x EVS265-B EVS265-E 5 wires through** 2 x Note. * For armored cable with continuity plate. ** For armored cable with 2 continuity plates. Technical information Lamps Fluorescent Lamp (order separately) T8 bi-pin tube, lampholder G3, diameter 26mm - white industry 4 K Photometric curve See page 82 Power factor.95 Wiring Configuration Electrical protection class Grounding system (NFC 5): Terminal block (spring) 5 wires TNS, TNC, TT, IT neutral system Jumped bar x2 terminal blocks 4mm² (rigid wire), 2.5mm² (flexible wire) Terminals supplied L, L2, L3, N, PE (looping possible with one additional cable gland) I Technical information Cable entries For non-armoured cable: For armoured cable: Housing Fixing (included with product) Three entries M2 Included two M2 nylon plugs (EX-M2) and one M2 nylon cable gland, diameter 6-2mm (EXCGM2S) and three nylon locknuts Included continuity plate - two M2 nylon plugs (EX-M2) and one M2 nickel plated brass cable gland, diameter 6-2/ 8.5-6mm (EXN4MMCK) Glass reinforced reinforced polyester housing for high impact strength, UV protected polycarbonate diffuser to resistant to harsh environments, Painted steel gear tray & Stainless steel 36L insert V5-2x Two zinc-plated steel brackets for ceiling mounting
3 ABB DTS LINEAR FITTINGS - EVS EM EMERGENCY FLUORESCENT FITTING - S, 2, 2 & 22 6 EVS EM Emergency fluorescent fitting with easy disconnect - 3h - zones, 2 & 2, 22 Dimensions 2 x M8 hole 2mm depth C B 37 mm 3 wires: Equipped with cable gland & 2 plugs A 7 mm Type For Dimensions mm Wiring Light Battery Current A non armored cable armored cable* Configuration Rating W 23V A B C EVS4EM- EVS4EM-C 3 wires x 36 3h EVS65EM- EVS65EM-C 3 wires x 58 3h EVS24EM- EVS24EM-C 3 wires 2 x 36 3h EVS265EM- EVS265EM-C 3 wires 2 x 58 3h Note. * For armored cable with continuity plate. Weight kg Electrical Features Lamps General data Fluorescent Lamp (order separately) T8 bi-pin tube, lampholder G3, diameter 26mm - white industry 4 K Photometric curve See page 82 Power factor.95 Wiring Configuration 3 wires Battery Battery NiCd 7.2V 4Ah in flameproof case (Ex d) Lumen output in mode ( lamp lit) 3 hours: 8% for EVS4, EVS24 3 hours: 4% for EVS65, EVS265 Monitored by LED Terminal block (screws plug in terminal block) Cable entries For non-armoured cable: For armoured cable: Housing Fixing (included with product) General data 4mm² (rigid wire), 2.5mm² (flexible wire) Terminals supplied L, N, PE (looping possible with one additional cable gland) Three entries M2 Included two M2 nylon plugs (EX-M2) and one M2 nylon cable gland, diameter 6-2mm (EXCGM2S) and three nylon locknuts Included continuity plate - two M2 nylon plugs (EX-M2) and one M2 nickel plated brass cable gland, diameter 6-2/ 8.5-6mm (EXN4MMCK) Glass reinforced reinforced polyester housing for high impact strength, UV protected polycarbonate diffuser to resist harsh environments, Painted steel gear tray & Stainless steel 36L insert V5-2x Two zinc-plated steel brackets for ceiling mounting Emergency function diagrams Wiring provided by DTS Maintained Mode Mains Supply Tube Battery 2 L ON Lit Charging Switch between L/2 Non Maintained Mode * Mains Supply Tube Battery 2 L ON Charging * This table corresponds to the position open. If the switch is on position close, refer to the table on the left
4 Material Drawn by Checked by Approved by Processing Description CE PLAN NE PEUT ETRE COMMUNIQUE OU REPRODUIT MEME PARTIELLEMENT SANS L'AUTORISATION DE DTS Tol. Class CUSTOMER DTS Scale Rev 62 ABB DTS LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES EVS EMA Emergency fluorescent fitting with automatic test & blackstart capabilities - zones, 2 & 2, 22 Dimensions 2 x M8 hole 2mm depth C B 37 mm 5 wires: Equipped with cable gland & 2 plugs A 7 mm Type For Dimensions mm Wiring Light Battery Current A non armored cable armored cable* Configuration Rating W 23V A B C EVS24EMA- EVS24EMA-D 5 wires 2 x 36 3h Note. * For armored cable with continuity plate. Weight kg Electrical Freatures Lamps Fluorescent Lamp (order separately) T8 bi-pin tube, lampholder G3, diameter 26mm - white industry 4 K Photometric curve See page 82 Rated voltages Electronic ballast Vac / 5-6Hz EOL (End of life) the ballast prevents the lamp cap at the end of lamp life cycle from Lumen output in mode ( lamp lit) 3 hours: 33% for EVS4, EVS24 Emergency function diagrams Monitored by two LED Electrical Freatures Terminal block Cable entries Terminals block up to 4mm² (rigid wire), 2.5mm² (flexible wire) Terminals supplied L, L2, L3, LS, N, E, BS (looping possible with one additional cable gland) Three entries M2 For non-armoured included two M2 nylon plugs (EX-M2) and cable: one M2 nylon cable gland, diameter 6-2mm Power factor.95 (EXCGM2S) and three nylon locknuts EVS EM A terminals EVS For EM armoured wiring A terminals diagram cable: wiring diagram included continuity plate - two M2 nylon Wiring Configuration 5 wires plugs (EX-M2) and one M2 nickel plated Battery Battery NiCd 6V 7Ah in f lameproof case (Ex d) for EVS4, Closed EVS24 loop option Closed loop option brass cable gland, diameter 6-2/ 8.5-6mm (EXN4MMCK) Housing E Bs Bs E Bs Bs N N Ls Ls LNLNL2LsL3LsE L3 E Fixing (included with product) Glass reinforced polyester housing for high impact strength, UV protected L L L2 polycarbonate diffuser to resist harsh environments, Painted steel gear tray & Stainless steel 36L insert V5-2x Two zinc-plated steel brackets for ceiling mounting Wiring provided by DTS Maintained Mode Mains Supply Tube Battery E Bs Bs E Bs Bs N N Ls Ls L L L2 L3 E ON Lit Charging Switched option Switched option Switch between LS/L Non Maintained Mode * Mains Supply Tube Battery ON Charging E Bs Bs E Bs Bs N N Ls Ls LNLNL2LsL3LsE L L L2 L3 E Switched option Switched option * This table corresponds to the position open. If the switch is on position close, refer to the table on the left Preventive maintenance mode Battery charge - daily Emergency lamp during min - weekly Battery charge capacity during hr - quarterly E Bs Bs N N Ls Ls L L L2 L3 E Clear system test display Battery charge monitored by 2 LED Operating on Mains Power. Battery Fully Charged Emergency or Indicator Lamp Fault (must be replaced) Test in Progress (waiting end of test) Fault (replace battery) Emergency function diagram - Blackstart mode The EMA product contains 2 blackstart terminals. The blackstart mode consists in disconnecting the battery and so switching off the fitting. This mode is mainl y used during maintenance. As soon as the maintenance is done, the main power ON and the blackstart terminals connected, the fitting is ready to be used as the battery is not discharged. EVS EM A terminals wiring diagram Switch between BS terminals Mains Supply Tube Battery Closed loop option E Bs Bs N N Ls Ls L L3 E ON Charging L L2 This table corresponds to the position open. Switched option E Bs Bs N N Ls Ls L L L2 L3 E Switched option
5 ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & accessories EVS - zones, 2 & 2, 22 Bipin T8 fluorescent lamps Type Power W Lumen output lm Lampholder TL8W 8 25 G3 TL36W G3 TL58W G3 Specifications G3 - ø 26mm Colour temperature: White industry 4 K CRI: > 8 lm/w: 65 to 93 Average operating life: 2 hours Fixing accessories* Brackets Type Specifications V5 2 x pair of zinc plated steel for ceiling mounting (Included with product) 25 ø9 V6 Stainless steel 36L brackets for ceiling mounting Hook Type Specifications 2 V24 2x Zinc plated steel suspension hook M Mounting bracket clip Type Specifications V4 2x Rapid ceiling mounting with stainless steel clip 6, 2 Ø 8.5 Fixing bracket and flange Type Specifications V8 2x zinc plated steel pole mounted brackets for ø ¼ & ½ 25 M8 V9 2x zinc plated steel pole mounted brackets for ø2 V2 2x Stainless steel 36L pole mounted brackets for ø ¼ & ½ V22 2x Stainless steel 36L pole mounted brackets ø2 α ø9 ~7 4 * Screws and locknuts supplied
6 64 ABB DTS LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES - spare parts EVS - zones, 2 & 2, 22 Spare parts Type Specifications V4 V V8 V5S V2W V4W V65W V4X2WS V4X4WS V4X65WS V42X2WS V42X4WS V42X65WS V4X4WEMS V42X2WEMS V4X65WEMS V42X65WEMS V42X4WEMAS V5S V8 2W diffuser with gasket for EV. range 4W diffuser with gasket for EV. range 65W diffuser with gasket for EV. range Gear tray x8w with electronic ballast 22-24Vac/Vdc 5-6Hz for EVS2 Gear tray X36W with electronic ballast 22-24Vac/Vdc 5-6Hz for EVS4 Gear tray X58W with electronic ballast 22-24Vac/Vdc 5-6Hz for EVS65 Gear tray 2X8W with electronic ballast 22-24Vac/Vdc 5-6Hz for EVS22 Gear tray 2x36W with electronic ballast 22-24Vac/Vdc 5-6Hz for EVS24 Gear tray 2x58W with electronic ballast 22-24Vac/Vdc 5-6Hz for EVS265 Emergency gear tray x36w with electronic ballast 22-24Vac/Vdc 5-6Hz for EVS4EM Emergency gear tray 2x8W with electronic ballast 22-24Vac/Vdc 5-6Hz for EVS22EM Emergency gear tray x58w with electronic ballast 22-24Vac/Vdc 5-6Hz for EVS65EM Emergency gear tray 2x58W with electronic ballast 22-24Vac/Vdc 5-6Hz for EVS265EM Emergency gear tray + auto test 2X36W with electronic ballast 22-24Vac/Vdc 5-6Hz for EVS24EMA Connection pack: XIN terminal, connector Bi-pin G3 lampholder V252x4W Brass continuity plate for EV. 2, EV. 22, EV. 4, EV. 24 V2565W Brass continuity plate for EV. 65, EV. 265 V V4WEMEA EXCGM2S EXN4MMCK Battery pack Ni-Cd 7.2v -4Ah for EVS4EM, EVS24EM Battery for EVS24EMA M2 Exe IIC nylon cable gland for non armoured cable diameter 6-2mm, locknut available separately as LNPB/M2 Kit M2 Ex-d IIC Ex-e II Ex-td double compression nickel plated cable gland for armoured cable diameter inner 6-2 outer 8.5-6mm locknut, sealing gasket
Linear fittings EVDL LED fitting - zones 21, & 22
ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield
More informationLinear fittings EVTL Weatherproof LED fitting - Industrial applications
89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted
More informationLinear fittings Fluorescent fitting EVN - Zones 2 & 22
Fluorescent fitting Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable
More informationLinear fittings EVN Fluorescent fitting - zones 2 & 22
LIEAR FITTIGS - EV FLUORESCET FITTIG - ZOES 2 & 22 71 EV Fluorescent fitting - zones 2 & 22 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray
More informationLinear fittings EVNL LED fitting - zones 2, & 22
65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress
More informationLinear fittings EVT Weatherproof fluorescent fitting - Industrial applications
LIEAR FITTIGS - EVT FLUORESCET FITTIG - IDUSTRIAL APPLICATIOS 95 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access
More informationLinear fittings EVTL Weatherproof LED fitting - Industrial applications
89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted
More informationLinear fittings EVT Weatherproof fluorescent fitting - Industrial applications
DTS LINER FITTINGS - EVT FLUORESENT FITTING - INDUSTRIL PPLITIONS 95 Features Double central locking for ingress protection ll components mounted on hinged and removable gear tray which gives easy access
More informationLinear fittings EVD Fluorescent fitting - zones 21 & 22
DTS LIER FITTIGS - EVD FLUORESET FITTIG - ZOES 21 & 22 83 EVD Fluorescent fitting - zones 21 & 22 Features Double central locking for ingress protection ll components mounted on hinged and removable gear
More informationTubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22
Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation
More informationTubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22
Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance
More informationWellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22
WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge
More information110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W
/27 V - 2/2 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE 963 39 Fluo 2 x 8 W 963 37 Fluo W 963 36 Fluo 2 x 8 W 8, 36 and 8 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G3
More informationEXEL-L. Detail of the internal side. Transparent polycarbonate
EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin
More informationLighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety
4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4
More informationEasy and safe installation
ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationLighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22
FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up 2 x 58 W 2 x18 W Compliance Data: ATEX IEC: Zone 2 22 ATEX IEC CE Ex nr II or na II T6 or T5 or T4
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationPROTECTA III. Construction Tough glass reinforced polyester body
PROTECTA III 20 Construction Tough glass reinforced polyester body Polycarbonate diffuser with high resistance to UV and stress cracking Robust hinges and multipoint compressive clamping of diffuser closure
More informationATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22
Applications Can be installed in hazardous areas designated as Zone 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against
More informationFluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety
Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Zone & & II GD IP66/67 IK0 Applications: Can be installed in hazardous
More informationFloodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2
Features Wide or narrow beam Ex e integral junction box Flat or pole mounting Supplied with lamp installed Including accessories (cable gland & plug) Supplied with offshore grade paint Manufactured from
More information2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
.4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency
More informationCompact Sheet-steel Emergency Light Fitting Series 6118/1
www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic
More informationATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationFL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22
Standard and Emergency Back-Up. Applications Light duty luminaire ideal for commercial and light industrial locations including hazardous areas designated as Zone 2 or 22 environments. Typical applications
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1, 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationFloodlight LED Series 6125
www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated
More information2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)
.15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationZone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108
Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More information1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection
More informationCompact Sheet-Steel Light Fittings Series 6114/1
> As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX 6600
> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationPower (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13
Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationEXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components
EXENC-L - Zone 2, Zone 21-22 - Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components Resin body reinforced polyester Fixing Brackets Transparent hood
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More information4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)
.7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation
More informationIIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof
IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless
More informationJ: Emergency lighting (optional) L: pole type X: ceiling type Mounting
Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More information4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)
.6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial
More informationEmergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408
> As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationL: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L
Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:
More informationLinear fluorescent luminaire LED V-CG-S
(2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K
More informationEmergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
> For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can
More informationAVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips
AVN - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C Transparent polycarbonate diffuser Stainless steel clips Polyamide cable gland and plug
More information7 Lighting Technology
7 Lighting Technology Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 The single-battery-supplied emergency lamps of the ECOLUX 6608 lighting series are employable as safety lighting
More informationLighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof
Ex de IIB Type PB Ex de IIC Type PC Ex de IIB Type PL Low Temperature Rating Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIB (PB and PL) T4 to T1 Ex td A21 T130 C to T378 C IP66 (Type
More informationZone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008
Lighting Technology Emergency Light Fittings Can be used in Zone 1 and Zone 2 As pendant or pole-mounting fittings For single- and two-pin fluorescent lamps With electronic ballast and integral emergency
More informationFloodlight Series 6121
www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options
More informationSheet Steel Emergency Light Fitting Series 6018
> For an operating duration of 1.5 or 3 h > Operating modes Continuous operation Continuous operation with switchable emergency light blocking > Weekly functional test > Total discharge protection and
More informationZone 1 Linear Range - Installation Guide
Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text
More informationWELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)
WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,
More information7 Lighting Technology
7 Lighting Technology Sheet-Steel Emergency Light Fitting 09361E00 and 6418 (Zones 2, 21 and 22) emergency light fittings in sheet-steel can be used for safety illumination, especially in spraying and
More informationTUNNEL54. Safety and fire resistance VENTILATION LIGHTING
TUNNEL54 Safety and fire resistance VENTILATION LIGHTING 238 TUNNEL54 Safety and fire resistance VENTILATION TUNNEL54 fire resistant sockets for ventilators Page 240 LIGHTING TUNNEL54 junction boxes with
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationIP65 FLUO 2X18W 2X36W
IP65 FLUO 2X18W 2X36W Features Housing made of reinforced polyester glass fiber (GRP) High transparent and impact resistant PC diffuser Both standard and emergency modes available Operation and survive
More informationOperating Instructions
Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationCompact Sheet-Steel Light Fittings Series 6114
> As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in
More informationStart Waterproof LED G3 fixed output START WATERPROOF LED G3 1500MM T 4K
Product features Start Waterproof, integrated LED weatherproof luminaire, with UV stabilized flat diffuser and linear prisms designed to achieve uniform lit appearance, optimise light output and to reduce
More information5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A
.1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationProtected
6.1 Protected 6.1 6.2 6.2 PPF1 PPF3 PPF4 PPF13 6.3 6.3 6.4 6.4 PPF11 PPF6 PPF5 PPF7 6.5 6.5 6.6 6.6 PPF8 PPF9 PPF10 PPF12 6.7 6.7 PPF14 1.9 1.9 1.10 1.10 1.11 1.11 1.12 1.10 Namibia- Pg 6 PPF1 Pluto vapourproof
More information4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)
.5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust
More informationexplosive environments Lighting
explosive environments Lighting CLASSIFICATION OF THE ZONES GAS AND VAPOURS DUST PRESENCE OF EXPLOSIVE ATMOSPHERE ZONE 0 ZONE 20 Category 1G Category 1D Permanent ZONE 1 ZONE 21 Category 2G Category 2D
More informationHAZ AREA LIGHTING. Product Brochure. Design to Manufacture FOR HAZARDOUS AREAS. Engineering Solutions. An A-Belco Group Company
HAZ AREA LIGHTING FOR HAZARDOUS AREAS Product Brochure Engineering Solutions Design to Manufacture An A-Belco Group Company The Hadar Lighting Range Designed and manufactured in the UK by A-Belco Hazardous
More informationCATALOGUE.
CATALOGUE www.dgr.com.my D TUBE LED D TL2 LED TUBE LED TUBE LIGHTING SERIES FAMILY NAME: LEMNIS TL2 1200 CORRELATED COLOUR TEMPERATURE: 3500K / 4000K / 5000K / 6500K PRODUCT CODE: 2R3MEB / 2R4MEB / 2R2MEB
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More informationATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen
Applications Designed for large area lighting in industrial outdoor and indoor hazardous areas. Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas industry. In locations such as: refineries,
More informationUSER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..
d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More informationFHL. Ex d. Body in aluminium
Ex d FHL Body in aluminium - Zones 1, 2, 21, 22 - Integrated electronic ballast - Power supply 24 V DC - Compact 24/36 W fluorescent tube - Degree of protection IP66 Guard in stainless steel Polycarbonate
More informationSheet-Steel Light Fittings Series 6014 / 6414
> As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive
More informationLight Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400
> As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life
More informationSPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz
ORION ROAD LANTERN Arc shape cooling guide design, resulting in effective heat dissipation and dust removal ability Combined optical lens, ideal for road lighting requirements Power-off protection socket,
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS ellb 20... 1-5 W Metallic design for Zone 1 and 21 The ellb 20 explosion-protected ceiling light fitting with electronic ballast meet the requirements of ATEX-Directive
More informationIndustrial luminaires
Industrial luminaires Acciaio 112 Leader BS 101 114 Leader BS 103 3G 115 Leader BS 111 116 Leader BS 113 117 Leader 21-01, 21-04 118 BS100, BS110 119 Tores 23-01 120 Castor 25-05 121 Lumino 26-91 122 Leo
More informationellk 92 LED Light Fittings
CEAG Products Ex-Solutions LED Lighting ellk 92 LED Light Fittings Linear light fitting series with new LED module for hazardous areas Zone 1, 2, 21 and 22 www.crouse-hinds.de EATON 1.2.1 Ex-LED-Linear
More informationProtecta III GRP ATEX
EOL Protecta III GRP ATEX INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read the following instructions carefully prior to installation or maintenance of this equipment. Types
More informationThe ultimate low voltage temporary LED lighting solution
LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkExTM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts
More informationControl Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations
Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC
More information