Linear fluorescent luminaire LED V-CG-S

Size: px
Start display at page:

Download "Linear fluorescent luminaire LED V-CG-S"

Transcription

1 (2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from hours Different luminous colours available 4000 K / 5600 K Single lamp operation during DC power supply (emergency operation) Enclosure made of reinforced polyester Double ended through-wiring with Ex-e cable infeeds for double-ended cable connection Shortened inspection effort due to CEWA GUARD technology Automatic function monitoring of up to 20 luminaires per circuit Reduced installation expenditure with STAR technologyfreely programmable mixed operation of the switching modes per luminaire in one circuit (2 x 26 W) Marking acc. to 94/9/EG II 2G Ex de mb II T4 Gb II 2D Ex tb IIIC T80 C Db IP66 EC-Type Examination Certificate BVS 09 ATEX E 034 IECEx-inspection certificate IECEX BVS Marking acc. to IECEx Ex de mb IIC T4 Gb Ex tb IIIC T80 C Db Housing material Glass fibre reinforced polyester Protective bowl Polycarbonate Rated voltage AC: V DC: V Circuit EVG / CG-S Rated current 0.5 A / 0.08 A (emerg. operation), () 0.25 A / 0.3 A (emerg. operation), () Power factor cos 0.95 Permissible ambient temperature 25 C up to + 45 C Cable infeeds Ex-e-cable glands M25 x.5 (plastic) for cables Ø 8-7 mm, Option: M20 x.5 metal thread Connection terminals L, L2, L3, L, N, PE; max. 2 x 6 mm 2 per terminal Light source LED module x 3 W () LED module x 26 W () Weight 7.4 kg (). kg () *With dust cover by unlocked entering/metal thread Ordering details Type Luminous colour Circuit open-circuit operation AC open-circuit operation ) DC Cos Order-No. 2 x M25, plastic gland 4000 K EVG/CG-S 0.5 A 0.08 A x M20, metal thread 4000 K EVG/CG-S 0.5 A 0.08 A x M25, plastic gland 4000 K EVG/CG-S 0.25 A 0.3 A x M20, metal thread 4000 K EVG/CG-S 0.25 A 0.3 A x M25, plastic gland 5600 K EVG/CG-S 0.5 A 0.08 A x M20, metal thread 5600 K EVG/CG-S 0.5 A 0.08 A x M25, plastic gland 5600 K EVG/CG-S 0.25 A 0.3 A x M20, metal thread 5600 K EVG/CG-S 0.25 A 0.3 A ) Only light source active during DC-operation Delivery without mounting accessories! 64 EMERGENCY LIGHTING Catalogue 707

2 Permissible number of luminaires per output circuit Connection with ellk 92 LED 400 CG-S ellk 92 LED 800 CG-S SKU 4 x A 6 4 SKU 2 x 3 A, SKU CG 2 x 3 A 2 2 SKU CG-S 2 x 3 A 9 2 SKU x 6 A, SKU CG x 6 A 8 8 SKU CG-S x 6 A SKU CG-S 4 x.5 A 6 6 Ceiling mounting bracket Ordering details fixing materials ellk 92 Type/ code Corrosion protection Qty. per light fitting Order No. Eye bolt A2 galvanized Hexagon screw S4 stainless steel Ceiling mounting bracket D92 incl. screws and washer stainless steel Ordering details fixing materials Type/ code Corrosion protectiong for pipes DIN Outer Ø D (mm) Qty. Order No. per light fitting Pipe clamp R2 hot galvanized / Pipe clamp R4 CrNi / Pipe clamp R22 hot galvanized / Pipe clamp R24 CrNi / Pipe clamp R32 hot galvanized Pipe clamp R34 CrNi Wall bracket W27 hot galvanized Luminaire wall suspension 30 incl. screws and washer hot galvanized EMERGENCY LIGHTING Catalogue

3 Planning help for ellk 92 LED 400 (4000K) V-CG-S (2 x 3 W) Mounting height [m] Types of mounting L L2 L3 L4 3.0 Escape route centre 5.9 (7) 3.5 (6) 5.3 (5.6) 0. (0.8) (7.7) 4.5 (7.5) 5.9 (6.5).6 (2) (8.2) 5.6 (8.7) 6.6 (7.) 3.0 (3.6) (8.7) 6.6 (20.) 7.2 (7.8) 2.5 (4.9) (9.) 7.2 (2) 7.8 (8.5) 3.0 (6.2) (9.5) 8.0 (22.2) 8.44 (9.) 3.6 (7.5) (9.9) 8.6 (22.9) 9.0 (9.8) 4. (7.2) (0.2) 9.3 (23.7) 9.5 (0.4) 5.0 (7.5) (0.5) 9.8 (24.6) 0.0 () 5.6 (8.) (0.7) 20.5 (25.4) 0.5 (.6) 6.5 (8.9) () 20.8 (26.).0 (2.2) 7. (9.3) (.2) 2. (26.6).4 (2.7) 7.7 (20) (.3) 2.4 (27.2).9 (3.3) 8.5 (20.7) (.5) 2.7 (27.7) 2.2 (3.8) 9. (2.5) (.6) 2.9 (28.3) 2.6 (4.3) 9.6 (22.3) 2.5 Ceiling mounting 4.4 (5.4) 0.6 (2.9).9 (2.) 7.2 (7.7) 3.0 Room illumination 4.2 (6).6 (4.3).9 (2.) 8.4 (8.6) (6.) 2.4 (5.) 2. (2.3) 9.3 (0) (5.7) 3.4 (5.9) 2. (2.5) 0.0 (.5) (5.9) 4.4 (7) 2. (2.5) 0.6 (2.2) (6) 5. (7.7) 2. (2.7).5 (3.2) (6.2) 6.5 (8.6).9 (2.8).8 (4) (6.8) 7.4 (9.9).7 (2.7) 2.4 (4.4) (6.8) 8. (20.4).7 (2.8) 3. (5.4) (7.2) 8.8 (2.5).6 (2.7) 3.8 (6) (7.8) 20.7 (22.8) 0.6 (2.5) 3.6 (6.4) (8.) 2.2 (23.6) 0.6 (2.5) 4.3 (7.) (8.9) 2.5 (24.9) 0.6 (2.) 5. (7.4) (9.) 2.9 (25.6) 0.5 (2.) 5.8 (8.) (8.7) 22.0 (25.6) 0.6 (2.4) 6.7 (9.3) (9.2) 22.3 (26.7) 0.5 (2.) 7.4 (9.7) (2.2) 24.3 (28.5) 2.2 (6.0).6 (5.5) (2.4) 24.8 (29.7).5 (5.9).4 (5.9) (2.5) 2.8 (30.8) - (5.5).0 (6.4) 66 EMERGENCY LIGHTING Catalogue 707

4 (2 x 3 W) Planning help for ellk 92 LED 400 (5600K) V-CG-S Mounting height [m] Types of mounting L L2 L3 L4 3 Escape route centre () () () () (7.9) 5.3 (8.) 6.0 (6.5).6 (2.6) (8.5) 6.4 (9.5) 6.7 (7.2) 3.0 (3.9) (9) 7.3 (20.7) 7.3 (7.9) 3.3 (5.2) (9.4) 8. (2.8) 7.9 (8.6) 3.5 (6.5) (9.9) 8.7 (22.9) 8.6 (9.3) 4.0 (7.9) (0.2) 9.5 (23.9) 9. (9.9) 4.7 (9.) (0.6) 20. (24.7) 9.7 (0.5) 5.5 (8.2) (0.9) 20.8 (25.6) 0.2 (.2) 6. (8.7) (.2) 2.3 (26.4) 0.7 (.8) 6.8 (9.4) (.4) 2.9 (27.).2 (2.3) 7.6 (20.2) (.7) 22.2 (27.7).7 (3) 8.3 (20.9) (.9) 22.5 (28.4) 2. (3.5) 8.8 (2.5) (2.) 22.8 (28.9) 2.6 (4.) 9.5 (22.2) (2.2) 23.2 (29.7) 3.0 (4.6) 20.2 (23) 2.5 Ceiling mounting 4.7 (5.5).0 (3.4).9 (2.) 7.2 (7.8) 3.0 Room illumination 4.4 (6.2).8 (4.5) 2. (2.3) 8.7 (8.9) (6.4) 2.9 (5.2) 2. (2.8) 9.4 (0.3) (5.8) 3.6 (5.4) 2.2 (3.6) 0.4 (2.4) (6.) 4.8 (7.5) 2.2 (2.6) 0.9 (2.6) (6.2) 5.6 (8.3) 2.2 (2.8).7 (3.5) (6.3) 6.8 (9.) 2. (2.9) 2.2 (4.4) (6.7) 7.9 (20.2).9 (2.9) 2.7 (5) (7.) 8.5 (2.2).9 (2.9) 3.5 (5.6) (7.4) 9.6 (22).6 (2.9) 3.9 (6.4) (7.8) 20.3 (23.).5 (2.8) 4.6 (7) (8.) 2.9 (24.) 0.7 (2.7) 4.6 (7.6) (8.7) 22.7 (25.2) 0.5 (2.5) 5. (8.) (9.) 23.0 (26.) 0.5 (2.4) 5.9 (8.7) (9.3) 23. (26.8) 0.6 (2.4) 6.8 (9.4) (9.2) 23.5 (27.2) 0.5 (2.5) 7.5 (20.3) (2.2) 24.3 (28.5) 2.2 (6.0).6 (5.5) (2.4) 24.8 (29.7).5 (5.9).4 (5.9) (2.5) 2.8 (30.8) - (5.5).0 (6.4) EMERGENCY LIGHTING Catalogue

5 Planning help for ellk 92 LED 800 (4000K) V-CG-S (2 x 26 W) Mounting height [m] Types of mounting L L2 L3 L4 3.0 Escape route centre () () () () 3.5 () () () () (9.6) 8.5 (22) 7.0 (7.6) 3.5 (4.4) (0.2) 9.8 (23.3) 7.7 (8.3) 4.9 (5.9) (8.9) 20.8 (24.7) 8.4 (9) 6.2 (7.2) (.3) 2.6 (25.9) 9. (9.8) 6.7 (8.6) (.8) 22.6 (27.2) 9.7 (0.5) 6.7 (20.) (2.2) 23.4 (28.) 0.3 (.) 7.2 (2.5) (2.6) 24. (29.) 0.9 (.8) 7.9 (22.8) (3) 24.9 (30.).5 (2.5) 8.6 (24.) (3.4) 25.3 (30.6) 2.0 (3.) 9.2 (23.2) (0.8) 26.2 (32) 2.6 (3.7) 20. (23.4) (4) 26.8 (32.6) 3. (4.3) 20.8 (23.9) 9.5. (4.3) 27.2 (33.5) 3.6 (4.9) 2.3 (24.7) 0.0. (4.5) 27.6 (34.3) 4. (5.5) 22.2 (25.4) 2.5 Deckenmontage 5.4 (6.4) 2.8 (5.5) 5.5 (5.5) 7.5 (8) 3.0 Room illumination 6.4 (6.4) 3.7 (6.4) 5.5 (6.5) 8.7 (9.6) (6.4) 3.7 (8.) 6.5 (7.5) 0.8 (0.5) (8.4) 5.7 (9) 7.5 (7.5).3 (.7) (9.4) 6.6 (9.7) 7.5 (7.5) 2. (3.) (9.4) 7.2 (9.6) 8.5 (8.5) 3. (5.4) (9.4) 8.3 (2.7) 8.5 (9.5) 3.7 (5.8) (0.4) 9.3 (20.5) 9.5 (9.5) 4.3 (8.4) (0.4) 20.3 (23.6) 9.5 (0.5) 5.0 (7.4) (0.4) 2.2 (24.3) 9.5 (.5) 5.7 (8.4) (.4) 22.3 (25.3) 0.5 (.5) 6.2 (9.) (.4) 23.5 (26.3) 0.0 (.5) 6.6 (9.7) (.4) 24.2 (27.3).5 (2.5) 7.3 (20.3) (2.4) 24.9 (28).5 (2.5) 8.0 (2.2) (2.4) 26.0 (29.5).5 (3.5) 8.4 (2.5) (3.4) 27.5 (30.4) 2.5 (3.5) 8.5 (22.2) (2.2) 24.3 (28.5) 2.2 (6.0).6 (5.5) (2.4) 24.8 (29.7).5 (5.9).4 (5.9) (2.5) 2.8 (30.8) - (5.5).0 (6.4) 68 EMERGENCY LIGHTING Catalogue 707

6 (2 x 26 W) Planning help for ellk 92 LED 800 (5600K) V-CG-S Mounting height [m] Types of mounting L L2 L3 L4 3.0 Escape route centre () () () () 3.5 () () () () 4.0 () () () () (0.6) 20.5 (24.2) 7.8 (8.4) 5. (5.9) (.2) 2.4 (25.5) 8.5 (9.2) 6.4 (7.4) (.7) 22.5 (26.8) 9.2 (9.8) 7.7 (8.9) (2.2) 23.5 (28.) 9.8 (0.6) 8.0 (20.3) (2.7) 24.3 (29.) 0.4 (.3) 8.2 (2.8) (3.) 25.2 (30.3). (2) 8.4 (23.) (3.5) 26.0 (3.3).7 (2.7) 9.2 (24.4) (3.9) 26.7 (32.3) 2.3 (3.3) 9.9 (25.8) (4.3) 27. (33.2) 2.8 (4) 20.6 (24.8) (4.6) 27.8 (34.2) 3.4 (4.6) 2.3 (24.9) (4.9) 28.4 (35) 3.9 (5.2) 22.0 (25.6) (5.2) 29.0 (35.7) 4.4 (5.8) 22.9 (26.) (6.4) 3. (5.6) 5.5 (5.5) 7.8 (8.4) 3.0 Room illumination 5.4 (6.4) 4.5 (7.2) 6.5 (6.5) 8.7 (9.6) (8.4) 5. (8.4) 6.5 (6.5) 0.2 () (8.4) 5.7 (9.8) 7.5 (7.5).9 (.9) (8.4) 7.3 (20.6) 7.5 (8.5) 2.4 (3.2) (8.4) 8. (2.6) 8.5 (9.5) 3.3 (4.5) (9.4) 9.0 (20.5) 8.5 (9.5) 4. (7.6) (9.4) 9.8 (23.6) 9.5 (0.5) 4.9 (7.) (0.4) 20.8 (24.7) 9.5 (0.5) 5.5 (7.8) (0.4) 2.9 (25.5) 0.5 (.5) 6. (8.7) (.4) 23. (26.3) 9.9 (.5) 6.6 (9.6) (.4) 23.8 (26.9) 0.5 (2.5) 7.4 (20.6) (2.4) 25.0 (27.9).5 (2.5) 7.8 (2.2) (2.4) 26.0 (29.3).0 (3.5) 8.3 (2.5) (3.4) 26.4 (30.) 2.5 (3.5) 9.2 (22.3) (3.4) 27.8 (3.).8 (3.5) 9.4 (23) (2.2) 24.3 (28.5) 2.2 (6.0).6 (5.5) (2.4) 24.8 (29.7).5 (5.9).4 (5.9) (2.5) 2.8 (30.8) - (5.5).0 (6.4) EMERGENCY LIGHTING Catalogue

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , 1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected

More information

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps .4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency

More information

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22) .15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent

More information

EX-RECESSED CEILING LIGHT FITTINGS

EX-RECESSED CEILING LIGHT FITTINGS EX-RECESSED CEILING LIGHT FITTINGS ellb 20... 1-5 W Metallic design for Zone 1 and 21 The ellb 20 explosion-protected ceiling light fitting with electronic ballast meet the requirements of ATEX-Directive

More information

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22) .6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial

More information

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22) .7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

Leading the way in hazardous areas Features EATON

Leading the way in hazardous areas Features EATON .2 Ex-escape sign luminaires EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22 Moulded plastic version with LED-technique Leading the way in hazardous areas The EXIT series of explosionprotected

More information

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

ellk/m 92 LED 400/800

ellk/m 92 LED 400/800 Explosion-protected Linear LED Light Fitting for Zone 1 and 21 1.1 ellk/m 92 LED 400/800 Linear LED Ex-light fittings ellk/m 92 LED 400/800 / ellk 92 LED 400/800 CG-S/NIB (Zone 1, 2, 21, 22) The efficient

More information

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings.  EATON 1.3.1 CEAG Products Main Catalogue Part 1 Chapter Emergency and safety light fittings www.crouse-hinds.de EATON 1..1 .1..2.1..2 EATON'S CROUSE-HINDS BUSINESS EATON Ex-Signal- and Rettungszeichenleuchten www.crouse-hinds.de

More information

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22) .5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust

More information

Linear luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002 > latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC > For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central

More information

ellk 92 LED Light Fittings

ellk 92 LED Light Fittings CEAG Products Ex-Solutions LED Lighting ellk 92 LED Light Fittings Linear light fitting series with new LED module for hazardous areas Zone 1, 2, 21 and 22 www.crouse-hinds.de EATON 1.2.1 Ex-LED-Linear

More information

Ordering details HL 43 d / ML 43 d / ML 50/60/70 d / ML 43/60 LED

Ordering details HL 43 d / ML 43 d / ML 50/60/70 d / ML 43/60 LED .6 Ordering details HL 43 d / ML 43 d / ML 50//70 d / ML 43/ LED Ordering details Hand lamps Dimensions Type Lamp power Voltage Lamp cap Luminous flux Ø B Ø C Weight Order No. HL43d LED6 4 6 W LED 85-264

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6409/1 > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually

More information

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

EX-FLUORESCENT LIGHT FITTINGS

EX-FLUORESCENT LIGHT FITTINGS 1 EX-FLUORESCENT LIGHT FITTINGS 2 3 5 6 EX-LIGHT FITTING ellk 92... MAIN FEATURES EX-LIGHT FITTING ellk 92... 2.20 2.12 7 EX-POLE MOUNTED LIGHT FITTING ellm 92... EX-EMERGENCY LIGHT FITTING ellk 92...

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600 > 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Load disconnect switch Series 8146/5-V11

Load disconnect switch Series 8146/5-V11 www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation

More information

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder

More information

EX-D ENCLOSURES AND DISTRIBUTIONS

EX-D ENCLOSURES AND DISTRIBUTIONS EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated

More information

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A .1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility

More information

LED Linear Luminaire Series EXLUX 6402

LED Linear Luminaire Series EXLUX 6402 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light .4 Ex-Searchlight series SEB 8.., SEB 9.. and SEB 0 (Zone, 2, 2, 22) Portable searchlights for harsh conditions The explosion-protected portable searchlight series SEB 8/9/0 provides a strong and reliable

More information

EX-FLUORESCENT LIGHT FITTINGS

EX-FLUORESCENT LIGHT FITTINGS 1 EX-FLUORESCENT LIGHT FITTINGS 2 Co oper Cr ouse se-hinds 200 - all righ ghts rese serv rved EX-LIGHT FITTING ellk 2... MAIN FEATURES 2.20 3 4 6 7 EX-LIGHT FITTING ellk 2... EX-POLE MOUNTED LIGHT FITTING

More information

Linear fittings EVDL LED fitting - zones 21, & 22

Linear fittings EVDL LED fitting - zones 21, & 22 ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield

More information

Type Scope of delivery Order unit Order No.

Type Scope of delivery Order unit Order No. Ordering details Serie SEB 8 / SEB 9 / SEB 0 Ordering details Type Scope of delivery Order unit Order No. SEB 0 with twin-lens high power LED system Lithium-Iron-Phosphate battery (rechargeable with LG

More information

I Ex-safety switches I

I Ex-safety switches I 3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

I Ex-safety switches I

I Ex-safety switches I EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX

More information

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , Product description 2 Product key features COOPER Crouse-Hinds EVZ series HID pendant luminaire is Ex de designed with rugged fixture and impact duration tempered glass globe. It has 2 versions with full

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

EX-REPAIR AND MAINTENANCE RECEPTACLES

EX-REPAIR AND MAINTENANCE RECEPTACLES EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand

More information

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108 Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating

More information

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408 > As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

I Ex-Safety switches I

I Ex-Safety switches I 3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX

More information

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVNL LED fitting - zones 2, & 22 65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources

More information

Terminal Boxes in Stainless Steel SLS**.T

Terminal Boxes in Stainless Steel SLS**.T Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations

More information

Style luminaires for the next generation

Style luminaires for the next generation Style LED CG-S Headline Style luminaires for the next generation Greater efficiency and less maintenance than ever before: LED technology for upgrading Style LED CG-S The Style series: a reliable concept

More information

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.

More information

Floodlight Series 6121

Floodlight Series 6121 www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22 WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge

More information

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400 > As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life

More information

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Main current switches >180 A are realized in metal enclosures. Internationally approved. E X - M A I N C U R R E N T S W I T C H E S 10 A - 80 A (up to 630 A) CEAG main current switches in a number of versions can be protected against inadvertent switching on by our integrated locking facility

More information

International approvals.

International approvals. E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:

More information

Luminaires CG-S Eaton. All Rights Reserved.

Luminaires CG-S Eaton. All Rights Reserved. Luminaires CG-S Agenda Applications / Requirements Luminaire Portfolio GuideLed Plastic Luminaires Escape Sign Panel Luminaires, LED Aluminium Luminaires Downlights Escape Sign Cubes Luminaires with High

More information

Position Switches Series 8060/2

Position Switches Series 8060/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Tubular Light Fitting with LED Series 6036

Tubular Light Fitting with LED Series 6036 > Extremely robust luminaire design for rough ambient conditions > Very lightweight and vibration resistant LED light fitting > Extremely long service life due to high power LEDs used including driver

More information

Internationally approved.

Internationally approved. E X - M A N U A L M O T O R S T A R T E R S Up to 2 A Motors have to be protected against over loads, phase failures and overheating: CEAG s power circuit breaker and manual motor starter features phase-failure

More information

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22 ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & 22 59 EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components

More information

Linear Luminaire for Fluorescent Lamps

Linear Luminaire for Fluorescent Lamps Linear Luminaire for Fluorescent Lamps Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding

More information

Dust - an Explosive Risk

Dust - an Explosive Risk CEAG Products for Dust Ex-Applications Dust - an Explosive Risk Safe Solutions from Eaton's Crouse-Hinds Division One spark may be enough. What can happen in areas with dust? Dust explosions are more dangerous

More information

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22 Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Terminal Boxes Series 8125

Terminal Boxes Series 8125 Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

Control Buttons / Switches for Panel Mounting Series 8003

Control Buttons / Switches for Panel Mounting Series 8003 www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch > 2 contact elements > Spring clamp

More information

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /.. d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer

More information

Central battery system ZB-S with STAR technology

Central battery system ZB-S with STAR technology Central battery system ZB-S with STAR technology As well as providing a dependable supply of power (30V AC/0 V DC) to safety and exit luminaires, the central battery system ZB-S tests itself automatically

More information

The ultimate low voltage temporary LED lighting solution

The ultimate low voltage temporary LED lighting solution LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkExTM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

The ultimate low voltage temporary LED lighting solution

The ultimate low voltage temporary LED lighting solution LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkEx TM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts

More information

New products Ex Equipment 2015

New products Ex Equipment 2015 New products Ex Equipment 2015 ROSE Systemtechnik GmbH ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany, in 199 and is today one of the world s leading and innovative providers of industrial

More information

Ex UPS standard Series 8265

Ex UPS standard Series 8265 > Guard battery monitoring according to IEC/EN 60079 et seq. > Adjustable buffer time > Battery function test > Potential-free signal outputs > Maximum efficiency > Increased for reliable triggering of

More information

ABG Cable Glands Installation Procedure

ABG Cable Glands Installation Procedure ABG Cable Glands Installation Procedure ABG Cable Gland Range Baseefa 16ATEX0004X IECEx BAS 16.0011X Installation, Operation and Maintenance Instructions Material: Brass/ Brass with Nickel plated and Stainless

More information

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22 Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance

More information

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE

More information

Complete Systems for Light Assembly

Complete Systems for Light Assembly F I X I N G S Y S T E M S Complete Systems for Light Assembly Individual assembly system for installing lamp systems can often be realised only at high cost with one-off manufacture. The patented Complete

More information

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:

More information

CEAG Products Main Catalogue Part 1 Chapter 1. Portable Ex-lighting

CEAG Products Main Catalogue Part 1 Chapter 1. Portable Ex-lighting CEAG Products Main Catalogue Part Chapter Portable Ex-lighting ..2 EATON www.crouse-hinds.de Portable Ex-lighting Table of contents. General information on portable Ex-lighting.....4.2 Ex-torchlight Series

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,

More information

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C Enclosures Flameproof - Group IIB or IIB + 2 Carbon steel - DE8BC series The flameproof control cabinets DE8BC are designed for the control, automation, distribution boards, motor starters or any other

More information

Linear fittings EVN Fluorescent fitting - zones 2 & 22

Linear fittings EVN Fluorescent fitting - zones 2 & 22 LIEAR FITTIGS - EV FLUORESCET FITTIG - ZOES 2 & 22 71 EV Fluorescent fitting - zones 2 & 22 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray

More information

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Linear fittings EVTL Weatherproof LED fitting - Industrial applications 89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted

More information

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13 Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - M A N U A L M O T O R S T A R T E R S Up to A Motors have to be protected against over loads, phase failures and overheating: CEAG's power circuit breaker and manual motor starter features phase-failure

More information