1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners E00 The light fittings of Series ECOLUX METALL 6010 can be used in Zone 1, 2 and 21, 22 for normal lighting, but also as group-supplied or centrally supplied emergency light fitting. The version with stainless steel metal enclosure is particularly suitable for marine applications. ATEX / IECEx Zone For use in x x x x Explosion Protection Global (IECEx) Gas and dust IECEx BVS X Ex d e IIC T4 Gb Ex tb IIIC T 80 C Db Europe (ATEX) Gas and dust Certifications and certificates Certificates BVS 14 ATEX E 129 X E II 2 G Ex de IIC T4 Gb E II 2 D Ex tb IIIC T80 C Db IECEx, ATEX, India (PESO) WebCode 6010A Lighting /1
2 Selection Table Version Lamps Cable glands ECOLUX METAL 6010 Note Through wiring Enclosure Order number Art. no. Weight 2 x 18 W Plastic M25 without Sheet Steel 6010/ without Stainless Steel 6010/ Plastic M20 without Sheet Steel 6010/ without Stainless Steel 6010/ x 36 W Plastic M25 without Sheet Steel 6010/ without Stainless Steel 6010/ Plastic M20 without Sheet Steel 6010/ without Stainless Steel 6010/ The light fittings are supplied without tubes. These must be ordered separately. Technical Data Electrical data Ballast 6010/ / Lamp start Cold start Cold start Voltage V AC V AC Voltage DC during switching on V DC V DC Voltage DC V DC V DC during operation Frequency 0 / Hz 0 / Hz Operation of the 1 lamp 2 lamps lamps DC Lamp standard IEC IEC Lamp power 18, 36 W 18, 36 W Nominal current 2 x 18 W, 170 ma 2 x 36 W, 320 ma 2 x 18 W, 170 ma 2 x 36 W, 320 ma Power factor cos p ) 0.97 Ambient conditions Operating temperature C range 6010/ / / Lamp start Cold start Cold start Cold start Voltage V AC V AC V AC Voltage DC during switching on V DC V DC V DC Voltage DC V DC V DC V DC during operation Frequency 0 / Hz 0 / Hz 0 / Hz Operation of the 1 lamp 2 lamps 2 lamps lamps DC Lamp standard IEC IEC ANSI C78.81 Lamp power 18, 36 W 18, 36 W 17, 32 W Nominal current 2 x 18 W, ma 2 x 36 W, ma 2 x 18 W, ma 2 x 36 W, ma 2 x 17 W, ma 2 x 32 W, ma /2 Lighting
3 Technical Data Mechanical data Degree of protection Protection class Material Enclosure IP66 for ceiling mounting IP65 for wall mounting IP64 when using breather 8162 IP67 (IEC 60598) I (with internal PE connection) Sheet steel powder coated Stainless steel SS304 (V2A ) powder coated, optional brushed Stainless steel (V4A ) powder coated, optional brushed Polycarbonate Quick locking device stainless steel Translucent cover Luminaire locking Colour colour white, similar to RAL 9010 Gasket Silicon foamed in translucent cover Mounting / Installation Cable glands 2x M20/M25 left and right, 1x cable glands and 3 stopping plugs as standard Connection Spring clamp terminal up to 4 mm 2 3-pole (2 x L1, 2 x N, 2 x PE) 5-pole (2 x L1, 2 x L2, 2 x L3, 2 x N, 2 x PE) Screw terminal up to 6 mm 2 3-pole (2 x L1, 2 x N, 2 x PE) 5-pole (2 x L1, 2 x L2, 2 x L3, 2 x N, 2 x PE) Through wiring Assembly option Suitable for wall and ceiling mounting. Mounting holes for screws M8 and elongated holes for screws M6 are available. Observe the assembly drawing. Light Distribution Curves cd/klm 74% C0 - C180 C90 - C cd/klm 74% C0 - C180 C90 - C E E00 2x 18 W 2x 36 W Accessories and Spare Parts Designation Figure Description Art. no. Weight Diffuser cover for light fitting 18 W for light fitting 36 W E00 Lighting /3
4 Accessories and Spare Parts Designation Figure Description Art. no. Weight Cable gland 02055E00 of moulded material, Series /7-M mm E /7-M pieces mm 2 (delivery lot *) ) /7-M mm /7-M pieces mm 2 (delivery lot *) ) Stopping plug of moulded material, Series E /3-M /3-M pieces /3-M25 x 1,5 s /3-M pieces Breathing gland 05703E00 for installation in lights; in moulded material; without counter nut Thread: M25 x pc Thread: M25 x pcs Lamp-holder Lamp holder G E00 Fluorescent lamp 04936E00 Two-pin cap d 26 mm Light colour: universal white Pins made of brass 18 W 1350 Im W 3350 Im /4 Lighting
5 Dimensional Drawings (all Dimension in mm [inch]) - Subject to Alterations 105 [4,13] 85 [3,35] Ø 8.50 [Ø 0,33] 60 [2,36] Z Z L3 Dimension Light fitting 18 W 36 W L [28,46] [52,48] L [27,48] [51,50] L [27,68] [51,69] 6 [0,24] 161 [6,34] L1 134 [5,28] 168 [6,61] L2 Light Fitting ECOLUX METAL Serie E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /5
Compact Sheet-Steel Light Fittings Series 6114/1
> As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive
More informationCompact Sheet-steel Emergency Light Fitting Series 6118/1
www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationFloodlight LED Series 6125
www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX 6600
> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless
More informationFloodlight Series 6121
www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationLight Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400
> As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationFloodlight Series 6521/4
> The enclosure made of stainless steel V4A, V2A or powder coated sheet steel is available > Broad or narrow beam reflectors and/or asymmetrical lamp fitting > Series 6521/3 explosion protected floodlight
More informationSheet-Steel Light Fittings Series 6014 / 6414
> As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationEmergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
> For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can
More informationTubular Light Fitting with LED Series 6036
> Extremely robust luminaire design for rough ambient conditions > Very lightweight and vibration resistant LED light fitting > Extremely long service life due to high power LEDs used including driver
More informationCompact Sheet-Steel Light Fittings Series 6114
> As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in
More informationEmergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408
> As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationPosition Switches Series 8060/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationPosition Switches Series 8074/2
www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,
More informationPlug and Socket Devices SolConeX 16 A Series 8570
Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationPosition Switches Series 8070/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationControl Buttons / Switches for Panel Mounting Series 8003
www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch > 2 contact elements > Spring clamp
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationSheet Steel Emergency Light Fitting Series 6018
> For an operating duration of 1.5 or 3 h > Operating modes Continuous operation Continuous operation with switchable emergency light blocking > Weekly functional test > Total discharge protection and
More information7 Lighting Technology
7 Lighting Technology Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 The single-battery-supplied emergency lamps of the ECOLUX 6608 lighting series are employable as safety lighting
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning
More informationControl switch/load disconnect switch Series 8008
> s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationLoad disconnect switch Series 8146/5-V11
www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation
More informationLinear fluorescent luminaire LED V-CG-S
(2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K
More informationLinear Luminaire for Fluorescent Lamps
Linear Luminaire for Fluorescent Lamps Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding
More informationBattery Boxes Series 8316
www.stahl.de > Back-up power supply > Maintenance-free batteries > Low self-discharge > Extremely low gas emissions > Electrolyte-tight > No acid surface coating > Protection against total disch arge >
More informationPlugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581
Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated
More informationEx UPS standard Series 8265
> Guard battery monitoring according to IEC/EN 60079 et seq. > Adjustable buffer time > Battery function test > Potential-free signal outputs > Maximum efficiency > Increased for reliable triggering of
More informationTubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22
Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation
More informationWellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22
WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact
More informationTerminal Boxes Series 8252/1
www.stahl.de > Ex d enclosure made of saltwater-resistant, copper-free aluminium cast alloy > Powder coated to RAL 7032 > Available in 3 different sizes > With DIN rail for standard terminals > Enclosure
More informationTubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22
Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance
More informationJ: Emergency lighting (optional) L: pole type X: ceiling type Mounting
Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone
More information4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)
.6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial
More informationLinear fittings EVDL LED fitting - zones 21, & 22
ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield
More information4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)
.7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation
More information1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection
More informationLeading the way in hazardous areas Features EATON
.2 Ex-escape sign luminaires EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22 Moulded plastic version with LED-technique Leading the way in hazardous areas The EXIT series of explosionprotected
More information2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
.4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency
More informationMetal Position Switch Series 8074
> Dimensions and characteristic values according to EN 50041 > Replaceable contact element in flameproof enclosure > Positive opening contacts > Wide range of actuators > All actuators can be displaced
More information7 Lighting Technology
7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources
More informationL: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L
Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:
More informationControl Buttons Series 8082
www.stahl.de > Contact element with 1 NO contact 1 NC contact, positive opening > Contact material silver-nickel or gold-plated > 9 different actuators Push Mushroom push Selector switch Rotary actuator
More information5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A
.1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationLinear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22
ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & 22 59 EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components
More informationPower (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13
Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.
More information7 Lighting Technology
7 Lighting Technology Sheet-Steel Emergency Light Fitting 09361E00 and 6418 (Zones 2, 21 and 22) emergency light fittings in sheet-steel can be used for safety illumination, especially in spraying and
More informationPortable Lamps Series HS6145, HSL145
www.stahl.de > Portable Lamps Series HS6145 > Comply with requirements of Fire Department standard DIN 14462 > Battery state display > Open circuit monitor > Light intensity 15.000 cd after 4 hours use
More information2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)
.15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent
More informationWELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)
WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,
More informationTank Inspection Lights Series 6122
> For halogen lamps 5 W to 100 W > Mounting options tilting hinge mounting bracket flange collar > Corrosion-resistant light metal enclosure > Connection options potted connection lead connection www.stahl.de
More informationLinear fittings EVNL LED fitting - zones 2, & 22
65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3
More informationLoad and Motor Switches, Load-Break Switches Series 8549
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Pick-off terminal block Auxiliary
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581
Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear
More informationZone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108
Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating
More informationSafety Switches Series 8537
Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part
More information4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)
.5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust
More informationLoad and Motor Switches, Load-Break Switches Series 8544
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Alligator clip Auxiliary
More informationLoad and Motor Switches, Load-Break Switches Series 8544
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: alligator clip auxiliary
More informationCCAI, CCAIF, CCAIF..H
CCAI, CCAIF, CCAIF..H - Zone 1, 2, 21, 22 - Group IIC - Stainless steel junction boxes - Choice of 4 sizes - IP66 AISI 316L stainless steel Grub screws for opening lid Lid opening system Detail of inside
More informationLinear Luminaire with LED
Linear Luminaire with LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3
More informationE II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc
900/77-80-094-001 158877 For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more compact, space-saving
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected
More informationK: bracket type. L: pole type
Lighting Technology Catalogue number logic B0091-0 -0 0 0 Pendant Light Fittings BDD91 Series Explosion-proof Light Fittings Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2
More informationEXEL-L. Detail of the internal side. Transparent polycarbonate
EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin
More informationRLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22
Ex de RLFE Mounting bracket - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Stainless steel guard Ex e terminal housing B.1 ED.2018
More information2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)
. Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected
More informationHTSB system System overview
HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.
More informationCEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1
CEAG Products Main Catalogue Part 1 Chapter Emergency and safety light fittings www.crouse-hinds.de EATON 1..1 .1..2.1..2 EATON'S CROUSE-HINDS BUSINESS EATON Ex-Signal- and Rettungszeichenleuchten www.crouse-hinds.de
More informationEWE. Ex de. Cooling fins
EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4
More information4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)
4 Remote I/O Series 86 078E00 Series 86 enclosures of glass-fibre reinforced polyester resin or of high grade steel are used in larger control stations and control station combinations. Special sizes are
More informationI Ex-safety switches I
EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX
More informationFHL. Ex d. Body in aluminium
Ex d FHL Body in aluminium - Zones 1, 2, 21, 22 - Integrated electronic ballast - Power supply 24 V DC - Compact 24/36 W fluorescent tube - Degree of protection IP66 Guard in stainless steel Polycarbonate
More informationOperating Instructions
Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety
More informationUSER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..
d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
Product description 2 Product key features COOPER Crouse-Hinds EVZ series HID pendant luminaire is Ex de designed with rugged fixture and impact duration tempered glass globe. It has 2 versions with full
More information