Load disconnect switch Series 8146/5-V11
|
|
- Rosamond Newton
- 5 years ago
- Views:
Transcription
1 Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN > Isolating characteristics acc. to IEC/EN > Positive opening operation of the main > Available for rated operating s of 16 A to 630 A > Robust enclosure made of glass fibre reinforced polyester > Large handle, lockable, or / red colours > Degree of protection IP E00 load and motor switches are used as main connection switches for distribution units and motor circuits. The standard range of switches have rated operating s up to 80 A. Switches for higher rated operating s are designed and manufactured to order. ATEX Class I (NEC 505) (NEC 506) Class I Class II Class III Zone Zone Division For use in x x x x For use in x *) For use in x *) *) Special version on request Explosion Protection Global (IECEx) Gas and dust 8146/5: IECEx PTB /5: Ex d e ia/ib [iaga] mb q IIA, IIB, IIC T6, T5, T4 Gb 8146/5: Ex tb IIIA, IIIB, IIIC T80 C, T95 C, T130 C Db Europe (ATEX) Gas and dust 8146/5: PTB 01 ATEX /5: E II 2 G Ex d e ia ib [ia Ga] mb q IIA, IIB, IIC T6, T5, T4 Gb 8146/5: E II 2 D Ex tb IIIA, IIIB, IIIC T80 C, T95 C, T130 C Db IP66 (marking on rating plate possible) Certifications and certificates Certificates IECEx, ATEX, Kazakhstan (TR), Russia (TR), Belarus (TR) WebCode 8146M Load disconnect switches and motor starters /1
2 Selection Table Version Enclosure material 10 A, 3-pole 10 A, 3-pole + N Equipment Colour Additional device Cable dia. range [mm] Order number Reversing switches are available only in V11, not as safety switches V37. Design 10 A Degree of protection IP66 acc. to IEC/EN Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 690 V AC Rated insulation 750 V Rated impulse 6 kv withstand Rated operational 10 A Switching capacity acc. to IEC/EN ; DIN VDE 0660, part 107 AC-3 U e I P 230 V ~ 400 V ~ 440 V ~ 10 A 10 A 10 A 2.2 kw 4.0 kw 4.0 kw 500 V ~ 10 A 5.5 kw 690 V ~ 10 A 7.5 kw Weight kg 8146/5-V , /5-V , /5-V , /5-V ,377 DC-1 DC-13 (L/R = 300 ms) U e I U e I 220 V 6 A 3) 230 V 0.4 A 1 conducting path 110 V 6 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 6 A 24 V 10 A /2 Load disconnect switches and motor starters
3 Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary Rated operating Rated operational Switch Terminals Type 8146/5-V operations 16 A, tripping characteristic: gg acc. to IEC/EN V AC 6 A 1 NO (ON delayed - OFF advanced) 2, mm 2 finely stranded / solid wire No. of poles max. [A] Conductor cross-section [mm 2 ] Main Auxiliary min. max. Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Temperature class / perm. ambient temperature ,5 4 T6: C T6: C T5: C ,5 4 T6: C T6: C T5: C Load disconnect switches and motor starters /3
4 Selection Table Version Enclosure material 16 A, 3-pole 16 A, 3-pole + N Equipment Colour Additional device Cable dia. range [mm] with N-terminal 2 x Order number Reversing switches are available only in V11, not as safety switches V37. Design 16 A Degree of protection IP66 acc. to IEC/EN Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 690 V AC Rated insulation 690 V Rated impulse 6 kv withstand Rated operational 16 A Weight kg 8146/5-V , /5-V , /5-V , /5-V , /5-V ,730 /4 Load disconnect switches and motor starters
5 Switching capacity acc. to IEC/EN ; DIN VDE 0660, part 107 AC-3 U e I P 230 V ~ 16 A 4.0 kw 400 V ~ 16 A 7.5 kw 440 V ~ 16 A 7.5 kw 500 V ~ 16 A 7.5 kw 690 V ~ 16 A 11.0 kw Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary Rated operating Rated operational Switch Terminals Ambient conditions 16 A Type 8146/5-V..- DC-1, DC- DC-13 (L/R = 300 ms) 23 U e I U e I 220 V 16 A 3) 250 V 1.1 A 1 conducting path 120 V 16 A 125 V 2.2 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 16 A 60 V 5.0 A operations 25 A, tripping characteristic: gg acc. to IEC/EN V AC 10 A 3-pole: 1 NO (ON delayed - OFF advanced) 6-pole: 2 NO (1 x ON delayed - OFF advanced / 1 x switching normally) mm 2 finely stranded / solid No. of poles max. [A] Conductor cross-section [mm 2 ] Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Temperature class / Perm. ambient temperature Main Auxiliary min. max T6: C T6: C T5: C T6: C T6: C T5: C Load disconnect switches and motor starters /5
6 Selection Table Version Enclosure material 20 A, 3-pole 20 A, 3-pole + N Equipment Colour Additional device Cable dia. range [mm] (M3, (M3, (M3, (M3, Order number Reversing switches are available only in V11, not as safety switches V37. Design 20 A Degree of protection IP66 acc. to IEC/EN Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 690 V AC Rated insulation 690 V Rated operational 20 A Switching capacity acc. to IEC/EN ; DIN VDE 0660, part 107 AC-3 U e I P 230 V ~ 20 A 5.5 kw 400 V ~ 20 A 7.5 kw 440 V ~ 20 A 11.0 W 500 V ~ 20 A 11.0 kw 690 V ~ 20 A 18.5 kw Weight kg 8146/5-V , /5-V , /5-V , /5-V ,815 Service life of electrical / mechanical parts DC-1, DC- DC-13 (L/R = 300 ms) 23 U e I U e I 220 V 20 A 3) 250 V 1.1 A 1 conducting path 120 V 20 A 125 V 2.2 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 20 A 60 V 5.0 A operations /6 Load disconnect switches and motor starters
7 Max. short-circuit protection Auxiliary Rated operating Rated operational Terminals Ambient conditions 20 A Type 8146/5-V A, tripping characteristic: gg acc. to IEC/EN V AC 10 A mm 2 finely stranded / solid No. of poles max. [A] Conductor cross-section [mm 2 ] Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate Temperature class / Perm. ambient temperature Main Auxiliary min. max T6: C T5: C T5: C Load disconnect switches and motor starters /7
8 Selection Table Version Enclosure material 25 A, 3-pole 25 A, 3-pole + N 25 A, 6-pole Equipment Colour Additional device Cable dia. range [mm] (M3, (M3, with N-terminal 2 x (M3, (M3, (M3, 4 x x x x Order number Reversing switches are available only in V11, not as safety switches V37. Design 25 A Degree of protection IP66 acc. to IEC/EN Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 690 V AC Rated insulation 690 V Rated operational 25 A Weight kg 8146/5-V , /5-V , /5-V , /5-V , /5-V , /5-V , /5-V ,839 /8 Load disconnect switches and motor starters
9 Switching capacity acc. to IEC/EN ; DIN VDE 0660, part 107 AC-3 AC-23 U e I P I P 230 V ~ 25 A 5.5 kw 400 V ~ 25 A 11.0 kw 440 V ~ 25 A 11.0 kw 500 V ~ A 15.0 kw V ~ 25 A 22.0 kw Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary Rated operating Rated operational Terminals Ambient conditions 25 A Type 8146/5-V operations 35 A, tripping characteristic: gg acc. to IEC/EN V AC 10 A mm 2 finely stranded / solid No. of poles max. [A] Conductor cross-section [mm 2 ] Main DC-1, DC- DC-13 (L/R = 300 ms) 23 U e I U e I 220 V 25 A 3) 250 V 1.1 A 1 conducting path 120 V 25 A 125 V 2.2 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 25 A 60 V 5.0 A Auxiliary Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate min. max. Temperature class / Perm. ambient temperature T6: C T5: C T5: C T6: C T5: C T5: C T6: C T5: C T5: C T6: C T5: C T5: C T6: C T5: C T5: C T5: C T5: C T5: C T5: C T5: C Load disconnect switches and motor starters /9
10 Selection Table Version Enclosure material 40 A, 3-pole 40 A, 3-pole + N 40 A, 6-pole Equipment Colour Additional device Cable dia. range [mm] 2 x (M40), 1 x x (M40), 1 x x (M40), 1 x x (M40), 1 x x (M40), 1 x x (M40), 1 x Order number Reversing switches are available only in V11, not as safety switches V37. Design 40 A Degree of protection IP66 acc. to IEC/EN Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 690 V AC Rated insulation 750 V Rated operational 40 A Weight kg 8146/5-V K 5, /5-V K 5, /5-V K 7, /5-V K 7, /5-V K 9, /5-V K 9,000 /10 Load disconnect switches and motor starters
11 Switching capacity acc. to IEC/EN ; DIN VDE 0660, part 107 AC-3 U e I P 240 V ~ 40 A 11.0 kw 400 V ~ 40 A 22.0 kw 440 V ~ 40 A 22.0 kw 500 V ~ 40 A 22.0 kw 690 V ~ 40 A 37.0 kw Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary Rated operating Rated operational Terminals Ambient conditions 40 A Type 8146/5-V operations 80 A, tripping characteristic: gg acc. to IEC/EN V AC 6 A mm 2 finely stranded / solid No. of poles max. [A] Conductor cross-section [mm 2 ] Main DC-23, DC- 1 U e I 220 V 40 A 3) 1 conducting path 120 V 40 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 40 A Auxiliary Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate min. max. Temperature class / Perm. ambient temperature K T6: C T6: C T5: C K T6: C T6: C T5: C K T6: C T5: C T5: C Load disconnect switches and motor starters /11
12 Selection Table Version 63 / 80 A, 3-pole 63 / 80 A, 3-pole + N 63 / 80 A, 6-pole Enclosure material Equipment Colour Additional device Cable dia. range [mm] 2 x (M50), 2 x (M50), 2 x (M50), 2 x (M50), 4 x (M50), 4 x (M50), Order number Reversing switches are available only in V11, not as safety switches V37. Weight kg 8146/5-V K 5, /5-V K 5, /5-V K 7, /5-V K 7, /5-V , /5-V ,473 Design 63 / 80 A Degree of protection IP66 acc. to IEC/EN Enclosure cover V11: In switching position ON locked, in OFF position removable Handle Can be locked with 3 padlocks in 0-position Cable entries Standard: In polyamide, Series 8161 Special: In metal Main Rated operational 500 V AC (80 A) / 690 V AC (63 A) Rated insulation 750 V Rated operational 63 / 80 A Switching capacity acc. to IEC/EN ; DIN VDE 0660, part 107 AC-3 AC-3 U e I P I P 230 V ~ 400 V ~ 440 V ~ 500 V ~ 690 V ~ 63 A 63 A 63 A 63 A 63 A 18.5 kw 30.0 kw 37.0 kw 37.0 kw 55.0 kw 80 A 80 A 80 A 80 A 22.0 kw 45.0 kw 45.0 kw 55.0 kw DC-23, DC- 1 U e I 220 V 80 A 3) 1 conducting path 120 V 80 A 2 conducting paths in series 3) 3 conducting paths in series 60 V 80 A /12 Load disconnect switches and motor starters
13 Service life of electrical / mechanical parts Max. short-circuit protection Auxiliary Rated operating Rated operational Terminals Ambient conditions 63 / 80 A Type 8146/5-V operations 63 A: 125 A, 80 A: 160 A, tripping characteristic: gg according to IEC/EN V AC 6 A mm 2 finely stranded / solid No. of poles max. [A] Conductor cross-section [mm 2 ] Main Auxiliary Engineering note: The maximum conductor cross-sections given were determined using the H07V. The minimum bending radius was assumed to be 4 x outer diameter in accordance with VDE only with heat-resistant cable > 70 C on cable entries or/and > 85 C on clamping points Grease: specified on rating plate min. max. Temperature class / Perm. ambient temperature K T6: C T6: C T5: C T6: C T5: C T5: C K T6: C T5: C T6: C T5: C T6: C T5: C T5: C T6: C T5: C T5: C T6: C T5: C T6: C T5: C T6: C T5: C T5: C T6: C T5: C We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Load disconnect switches and motor starters /13
14 Dimensional drawings (all dimensions in mm) - subject to alterations B C A Circuit diagrams 04120E00 Dimensions [mm] A B C pole 10 A 8146/5-V /5-V A 8146/5-V /5-V /5-V A 8146/5-V /5-V A 8146/5-V /5-V /5-V A 8146/5-V K /5-V K / 80 A 8146/5-V K /5-V K pole 25 A 8146/5-V A 8146/5-V K / 80 A 8146/5-V E E00 -V pole + 1 NO (1x ON delayed - OFF leading / 1 x switching normally) -V pole N E00 N E00 -V pole + N -V pole + N ( 3) 5 7 (9) (8) (10) 12196E E00 -V V pole reversing switch -V pole /14 Load disconnect switches and motor starters
15 Accessories and Spare Parts Designation Figure Description Art. no. Weight Auxiliary contact 2 NC (8080/1-3) NC contact + 1 NO contact (8080/ kg 12446E00 2 NO (8080/1-4) The switching function of the auxiliary contact depends on the installation slot used. Left: delayed (ON), leading (OFF); Right: synchronising Left and right: synchronising Note: The auxiliary can only be retrofitted for 40 A and 63/80 A versions. For all other versions, the auxiliary contact must be ordered separately when placing the order. Retrofitting is not possible for this. Auxiliary contact key for removing the mounted auxiliary contact E00 Load disconnect switches and motor starters /15
Safety Switches Series 8537
Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning
More informationPlug and Socket Devices SolConeX 16 A Series 8570
Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control
More informationControl switch/load disconnect switch Series 8008
> s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact
More informationControl Buttons / Switches for Panel Mounting Series 8003
www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch > 2 contact elements > Spring clamp
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581
Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear
More informationLoad and Motor Switches, Load-Break Switches Series 8544
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: alligator clip auxiliary
More informationLoad and Motor Switches, Load-Break Switches Series 8544
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Alligator clip Auxiliary
More informationLoad and Motor Switches, Load-Break Switches Series 8549
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Pick-off terminal block Auxiliary
More informationPlugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581
Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked
More informationPosition Switches Series 8074/2
www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationPosition Switches Series 8060/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationPosition Switches Series 8070/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of
More information10 Load and Motor Switchgear
10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX 6600
> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600
More informationControl Buttons Series 8082
www.stahl.de > Contact element with 1 NO contact 1 NC contact, positive opening > Contact material silver-nickel or gold-plated > 9 different actuators Push Mushroom push Selector switch Rotary actuator
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationFloodlight LED Series 6125
www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More information5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A
.1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationEmergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408
> As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationEx UPS standard Series 8265
> Guard battery monitoring according to IEC/EN 60079 et seq. > Adjustable buffer time > Battery function test > Potential-free signal outputs > Maximum efficiency > Increased for reliable triggering of
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More informationMetal Position Switch Series 8074
> Dimensions and characteristic values according to EN 50041 > Replaceable contact element in flameproof enclosure > Positive opening contacts > Wide range of actuators > All actuators can be displaced
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless
More informationCompact Sheet-Steel Light Fittings Series 6114/1
> As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive
More informationTubular Light Fitting with LED Series 6036
> Extremely robust luminaire design for rough ambient conditions > Very lightweight and vibration resistant LED light fitting > Extremely long service life due to high power LEDs used including driver
More informationLight Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400
> As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life
More informationFloodlight Series 6121
www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationControl Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België
Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part
More information11 Control Panels, Distribution Panels and Components
Control Panels, Distribution Panels and Components Motor Switches Explosion protection to CENELEC IEC For use in Zone and Zone Isolator Motor switching capacity Rated working voltage up to Rated working
More informationE II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc
900/77-80-094-001 158877 For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more compact, space-saving
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder
More informationCompact Sheet-steel Emergency Light Fitting Series 6118/1
www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic
More informationI Ex-safety switches I
EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX
More informationBattery Boxes Series 8316
www.stahl.de > Back-up power supply > Maintenance-free batteries > Low self-discharge > Extremely low gas emissions > Electrolyte-tight > No acid surface coating > Protection against total disch arge >
More informationPortable Lamps Series HS6145, HSL145
www.stahl.de > Portable Lamps Series HS6145 > Comply with requirements of Fire Department standard DIN 14462 > Battery state display > Open circuit monitor > Light intensity 15.000 cd after 4 hours use
More informationI Ex-Safety switches I
3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX
More informationFloodlight Series 6521/4
> The enclosure made of stainless steel V4A, V2A or powder coated sheet steel is available > Broad or narrow beam reflectors and/or asymmetrical lamp fitting > Series 6521/3 explosion protected floodlight
More information8150 Series Terminal Boxes
8150 Series Terminal Boxes TEMINATION eady-term 8150 Terminal Boxes Features Enclosures made of stainless (AISI 304) or (AISI 316L) Optional hinges with cam locks or screws cover Hinged Versions 130 opening
More informationControl Device System NEC Series ConSig 8040
16113E00 > Enclosure made of glass fibre reinforced polyester resin > Modular design > 3 sizes available > Individual units can be combined into larger units > Standard and customer-specific versions >
More informationSheet-Steel Light Fittings Series 6014 / 6414
> As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationOperating Instructions
Operating Instructions Load and Motor Switch, Load-Break Switch > 8544/1 Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical
More informationLinear fluorescent luminaire LED V-CG-S
(2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K
More informationTerminal Boxes Series 8252/1
www.stahl.de > Ex d enclosure made of saltwater-resistant, copper-free aluminium cast alloy > Powder coated to RAL 7032 > Available in 3 different sizes > With DIN rail for standard terminals > Enclosure
More informationCompact Sheet-Steel Light Fittings Series 6114
> As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in
More informationI Ex-safety switches I
3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99
More informationHTSB system System overview
HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.
More information2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
.4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency
More informationEmergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
> For fluorescent lamps 2 x 18 W and 2 x 36 W > For emergency light operation periods of 1.5 or 3 hrs > During emergency time: If emergency lamp broken changing to the other lamp > Battery case which can
More informationEX-D ENCLOSURES AND DISTRIBUTIONS
EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated
More informationMain current switches >180 A are realized in metal enclosures. Internationally approved.
E X - M A I N C U R R E N T S W I T C H E S 10 A - 80 A (up to 630 A) CEAG main current switches in a number of versions can be protected against inadvertent switching on by our integrated locking facility
More informationOperating Instructions
Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety
More informationM-0. M-0... series control, monitoring and signalling devices. Ex e
M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationJ: Emergency lighting (optional) L: pole type X: ceiling type Mounting
Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationTank Inspection Lights Series 6122
> For halogen lamps 5 W to 100 W > Mounting options tilting hinge mounting bracket flange collar > Corrosion-resistant light metal enclosure > Connection options potted connection lead connection www.stahl.de
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE
More informationInternationally approved.
E X - M A N U A L M O T O R S T A R T E R S Up to 2 A Motors have to be protected against over loads, phase failures and overheating: CEAG s power circuit breaker and manual motor starter features phase-failure
More informationSheet Steel Emergency Light Fitting Series 6018
> For an operating duration of 1.5 or 3 h > Operating modes Continuous operation Continuous operation with switchable emergency light blocking > Weekly functional test > Total discharge protection and
More informationI 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I
I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de
More information1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
1/122 Explosion Protected Safety Luminaire and Escape Sign Luminaires Approved for explosive areas with gas explosion-hazard zones 1 and 21 as well as dust explosion-hazard zones 2 and 22 High IP66 protection
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More information7 Lighting Technology
7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3
More informationEx m Solenoid Operator Type 0519
nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application
2-3.1 ATC 510/520/525 for wall-mounting Application The ATC 510/5205/525 is a modern microprocessor-based (PID) control device featuring easy handling and a digital display. The clear design of the operator
More informationCable resistance thermometer Model TR40
Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 2 Applications For direct installation into the process Machine building
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - M A N U A L M O T O R S T A R T E R S Up to A Motors have to be protected against over loads, phase failures and overheating: CEAG's power circuit breaker and manual motor starter features phase-failure
More informationFlameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C
Enclosures Flameproof - Group IIB or IIB + 2 Carbon steel - DE8BC series The flameproof control cabinets DE8BC are designed for the control, automation, distribution boards, motor starters or any other
More informationThe cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals
E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.
More informationExplosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion
Ex-protection Explosion protection Valves for fluid technology for use in explosion hazard areas Explosion protection for gas, dust and mining Flameproof enclosures and intrinsic safety Solutions for all
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL
More informationTerminal Boxes in Stainless Steel SLS**.T
Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations
More informationALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES
Ex d IIB+H 2 ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES ALUMINIUM ENCLOSURES STAINLESS STEEL ENCLOSURES EJB... series enclosures offer Ex d IIB +H 2 mode of protection. These enclosures are
More informationLinear Luminaire for Fluorescent Lamps
Linear Luminaire for Fluorescent Lamps Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding
More informationPXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES
PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS II2 G D Ex e ia or ib IIC FROM 12 TO 37 CONTACTS LOCKING IN CONNECTED OR DISCONNECTED POSITION CORROSION-FREE METAL CASING TECHNICAL FEATURES PXN12C DXN25C
More information