CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

Size: px
Start display at page:

Download "CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies"

Transcription

1 Selection Checklist CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Use this checklist to help you configure your CENTERLINE 2500 Motor Control Center. You can type in the fields provided and check the checkboxes to select your preferences. Customer Office Certifications and Markings rabs rabs Shipboard rce rccc rgost-r ribc 2010 ricc-es rsei/asce rother (specify) Incoming Power Line voltage: r 380/415V r 440/460/480V r 525/575V r 690V System power: r Delta r Grounded Delta r Grounded Wye r Grounded Wye with impedance Frequency: r 50 Hz r 60 Hz Available fault current: ka Control Power Voltage: r 24V DC r 110/115/120V AC r 220/230/240V AC Source: r Individual control transformer: r Standard VA r Extra capacity r Central control power transformer r Remote control power source Control Terminal Blocks Location: r Top horizontal wireway r Vertical wireway Structure Enclosure rating: r IP 20 (vented doors) r IP 40 (vented doors with filters) r IP 42 (non-vented, standard) r IP 54 (fully gasketed, doors and bottom plates) ArcShield : r Yes r No Forms of internal separation: r 2b r 3b (standard) r 4b Mounting configuration: r Stand alone r Add to existing r Front only r Double front Depth: r 600 mm r 800 mm Width: r 600 mm (only fixed mount, no vertical wireway) r 700 mm (200 mm vertical wireway) r 800 mm (300 mm vertical wireway) r 900 mm (400 mm vertical wireway) r 1000 mm (500 mm vertical wireway) Options: r Space heater with thermostat r Cable supports r Other (specify) External paint: r RAL7032 Pebble Gray (standard) r Other (specify) Internal paint: r G90 galvanized steel (standard) r High visibility gloss white (optional) r Other (specify) Ambient temperature: C maximum Altitude: meters Bus Fault rating/bracing: r 50 ka for 3 cycles r 50 ka for 1 second r 50 ka for 3 seconds r 65 ka for 3 cycles r 80 ka for 1 second r 100 ka for 1 second Horizontal power bus: Rating: r 800 A r 1250 A r 1600 A r 2000 A r 2500 A r 3200 A r 4000 A Material: r Copper, unplated r Copper, tin plated (standard) Neutral bus: r Full rated r Half rated r None Vertical distribution bus rating: r 300 A, tin plated copper (standard; provides 600 A capacity) r 600 A, tin plated copper (provides 1200 A capacity) Protective earth (PE) conductor: Horizontal Location: r Bottom (standard) Material: r Copper, unplated r Copper, tin plated (standard) Size: r 1-6 x 50 mm r 2-6 x 50 mm r 3-6 x 50 mm Vertical Plug-in material: r Copper, unplated r Copper, tin plated (standard) Load material (optional): r None r Copper, unplated r Copper, tin plated (standard) Load location: r Vertical wireway (standard) Stab openings: r Automatic shutters (standard) User

2 IntelliCENTER Embedded system r DeviceNet r EtherNet/IP If EtherNet/IP, select one of the following: r Stratix 5700 r Stratix 8000 Software r None r Only Standard Data CD (1) Quantity: r Only Energy Data CD (1) Quantity: r IntelliCENTER software and Standard Data CD (1)(2) Data CD quantity: r IntelliCENTER software and Energy Data CD (1)(2) Data CD quantity: Other Network Options r Profibus r ControlNet r DeviceNet-to-Ethernet linking device r DeviceNet-to-ControlNet linking device r DeviceNet-to-Profibus linking device Incoming Cable Termination/Provision Ampere rating: A Located in column number: Where located: r Top r Bottom Number of cables per phase: Cable size: Main: r Main lug only (MLO) with crimp compression lugs r MLO with mechanical lugs r MLO without supplied lugs r Main fusible disconnect (MFD) with supplied fuses If supplied, fuse type: r MFD without supplied fuses r Ground fault main circuit breaker (MCB) r Shunt trip MCB Auxiliary contacts (quantity): Other (specify): r Current transformers required for MCB (quantity): r Potential transformers required for MCB (quantity): r Main air circuit breaker (MACB) with electrical charging device r MACB with closing release r MACB with shunt release r MACB with undervoltage release Incoming metering options: r Analog ammeter r Ammeter switch r Analog voltmeter r Voltmeter switch r PowerMonitor 500 r PowerMonitor 5000 Outgoing Cable Termination/Provision Ampere rating: A Number of cables per phase: Cable size: Lug type: r Crimp compression lugs r Mechanical lugs r Lugs not supplied Feeder Units Fuse switch: r Fuses supplied If supplied, fuse type: r Fuses not supplied Circuit breaker (thermal magnetic): Interrupting rating: ka Ampere rating: A Other: Nameplates Type: r Cardholder r Engraved acrylic r Engraved phenolic Color scheme: r Black letters on white r White letters on black (phenolic only) Door Latches Latch type: r 1/4 turn r Other (specify): Wire Markers Marker type: r Sleeve r Data tab r Heat shrink Spares r Spare parts r Spare units r Other (specify): Direct Online Starter Units (3) Unit type: r Non-reversing starter r Reversing starter Ampere rating: A Kilowatt rating: kw Disconnecting means: r Fused (rotary operator only) Fuse type: r Fuses not supplied r Circuit breaker Handle operator: r Rotary operator r Flange operator (2 module minimum) Overload type: r E300 r E1 Plus r E1 Plus w/ground fault r E3 Plus r E3 Plus w/ground fault r E3 Plus w/voltage protection and energy monitoring Overload reset: r External (door mounted) Duty rating: r AC3 (standard) r AC4 Protection: r Type 1 r Type 2 Unit type: r Withdrawable r Semi-withdrawable r Fixed (1) You must purchase a copy of the Standard or Energy Data CD for each MCC lineup connected to the IntelliCENTER software. (2) You must purchase a copy of IntelliCENTER software for each personal computer or HMI used to communicate with a MCC lineup. Personal computers or HMIs cannot share copies of IntelliCENTER software but the IntelliCENTER software can access multiple MCC lineups. (3) Copy this section and complete for each unit needed. 2 Rockwell Automation Publication 2500-SR001F-EN-P - June 2014

3 Options and Accessories Pilot lights r Yes Quantity: r No Light type: r Push to test r LED lamps r Forward/reverse (available only for reversing starter units) Text on legend plate: r On r Off r Fault r Emergency r Other (specify): Push buttons r Yes Quantity: r No Text on legend plate: r On r Off r Reset r Emergency r Other (specify): Selector switch: r 2-position r 3-position r None Function: E300 control stations r Yes Quantity: r No If yes, station type: r Control r Diagnostic Starter auxiliary contacts: r Normally open Quantity: r Normally closed Quantity: Relays or timers (describe; use Notes section below if additional space is needed): Others (describe; use Notes section below if additional space is needed): Notes (use Notes section on page 7 if additional space is needed) Rockwell Automation Publication 2500-SR001F-EN-P - June

4 Soft Starter Units (1) Unit type: r SMC -3 r SMC Flex Connection: r Line r Delta Ampere rating: A Kilowatt rating: kw Disconnecting means: r Fused (rotary operator only) Fuse type: r Fuses not supplied r Circuit breaker Handle operator: r Rotary operator r Flange operator (2 module minimum) Unit type: r Withdrawable r Semi-withdrawable r Fixed Options and Accessories Pilot lights r Yes Quantity: r No Light type: r Push to test r LED lamps Text on legend plate: r Start r Stop r Other (specify): Push buttons r Yes Quantity: r No Text on legend plate: r On r Off r Fault r Other (specify): Selector switch: r 2-position r 3-position r None Function: Human-machine interface (HMI): r LCD display, full numeric keypad r LCD display, programmer only Starting mode: r Pump control r Braking control Others (describe; use Notes section below if additional space is needed): Notes (use Notes section on page 7 if additional space is needed) (1) Copy this section and complete for each unit needed. 4 Rockwell Automation Publication 2500-SR001F-EN-P - June 2014

5 PowerFlex AC Variable Frequency Drive (VFD) Units (1) Unit type: r PowerFlex 523 r PowerFlex 525 r PowerFlex 753 r PowerFlex 755 Rating: r Normal duty r Heavy duty Ampere rating: A Kilowatt rating: kw Disconnecting means: r Fused (rotary operator only) Fuse type: r Fuses not supplied r Circuit breaker Handle operator: r Rotary operator r Flange operator (2 module minimum) Unit type: r Withdrawable r Semi-withdrawable r Fixed Options and Accessories Pilot lights r Yes Quantity: r No Light type: r Push to test r LED lamps Text on legend plate: r Start r Stop r Other (specify): Push buttons r Yes Quantity: r No Text on legend plate: r On r Off r Fault r Other (specify): Selector switch: r 2-position r 3-position r None Function: Human-machine interface (HMI): r LCD display, full numeric keypad r LCD display, programmer only Braking mode: r Pump control r Braking control Reactor type: r Line r Load Others (describe; use Notes section below if additional space is needed): Notes (use Notes section on page 7 if additional space is needed) (1) Copy this section and complete for each unit needed. Rockwell Automation Publication 2500-SR001F-EN-P - June

6 DeviceNet Power Supply Unit Type: r Primary r Redundant r Back-up r User-supplied external Location (specify): EtherNet/IP Power Supply Unit Type: r Primary r Redundant r Back-up r User-supplied external Location (specify): Miscellaneous Units (1) r Programmable controllers Number of slots: Power supply: Describe what you need (use Notes section on page 7 if additional space is needed) r Distribution panels 1-pole quantity: 2-pole quantity: List circuit loads (use Notes section on page 7 if additional space is needed) r Extra space for future units Describe what you need (use Notes section on page 7 if additional space is needed) Motor List Unit Description Rating Module Size (1) Copy this section and complete for each unit needed. 6 Rockwell Automation Publication 2500-SR001F-EN-P - June 2014

7 Notes Rockwell Automation Publication 2500-SR001F-EN-P - June

8 Allen-Bradley, ArcShield, CENTERLINE, E1 Plus, E3 Plus, E300, IntelliCENTER, PowerMonitor, Rockwell Automation, Rockwell Software, SMC, Stratix 5700, Stratix 8000, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 2500-SR001F-EN-P - June 2014 Supersedes 2500-SR001E-EN-P - March 2011 Copyright 2014 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

CENTERLINE 2500 Low Voltage Motor Control Centers and Power Distribution Gear Catalog Structure Breakdown

CENTERLINE 2500 Low Voltage Motor Control Centers and Power Distribution Gear Catalog Structure Breakdown Technical ata CENTERLINE 2500 Low Voltage Motor Control Centers and Power istribution Gear Catalog Structure Breakdown Catalog Numbers 2500 Table of Contents Topic Page Additional Resources 2 Ordering

More information

CENTERLINE 2100 Motor Control Centers Selection Guide. Industry-Leading Motor Control Centers Delivering Safety, Performance and Reliability

CENTERLINE 2100 Motor Control Centers Selection Guide. Industry-Leading Motor Control Centers Delivering Safety, Performance and Reliability CENTERLINE 2100 Motor Control Centers Selection Guide Industry-Leading Motor Control Centers Delivering Safety, Performance and Reliability 2 CENTERLINE 2100 Motor Control Centers Selection Guide What

More information

Variable Frequency AC Motor Drive Units

Variable Frequency AC Motor Drive Units 14 Variable Frequency A Motor Drive Units ulletin 2162T and 2163T PowerFlex 40 Drive................................................. 171 These combination variable frequency A motor drive units are specifically

More information

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500 Installation Instructions CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns Catalog Number 2500 Topic Page Important User Information 2 Location Planning 3 Environment 3 Removal

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

CENTERLINE 2100 Motor Control Centers

CENTERLINE 2100 Motor Control Centers TECHNICAL DATA CENTERLINE 2 Motor Control Centers Instantaneous Trip Motor Circuit Protectors (MCP) in Combination NEMA Starter, Soft Starter (SMC) and Variable Frequency AC Drive Units 1A Frame Instantaneous

More information

SMC -50 Reduced Voltage Solid-State Smart Motor Controllers

SMC -50 Reduced Voltage Solid-State Smart Motor Controllers ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION SMC -50 Reduced Voltage Solid-State Smart Motor Controllers NOTICE: The specification guidelines in this document are intended to

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

Selection Guide. PowerFlex Digital DC Drive

Selection Guide. PowerFlex Digital DC Drive Selection Guide PowerFlex Digital DC Drive PowerFlex Digital DC Drive The PowerFlex DC drive combines powerful performance with flexible control to produce a highly functional, cost effective drive and

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types: SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch Installation Instructions Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch Catalog Numbers 2193FZ Topic Page About This Publication 1 Required Tools 1 Important User Information 2

More information

Control and Load Switch Specifications Bulletin Number 194E, 194L

Control and Load Switch Specifications Bulletin Number 194E, 194L Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13

More information

Pump Panel Specifications

Pump Panel Specifications Technical Data Pump Panel Specifications Bulletin Numbers 13 and 133 Topic Page Specifications Electrical Ratings (Bulletins 13, 13X, 133, 133X) Mechanical Ratings (Bulletins 13, 13X, 133, 133X) 3 Construction

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

PSE The efficient range Description

PSE The efficient range Description Description The PSE softstarter range is the world s first compact softstarters with Torque Control. This makes the PSE range an excellent choice for pumping application where water hammering normally

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2 SECTION 1. 600V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2 Soft Starters SECTION 2. LIQUID COOLED VFD I 3 Liquid Cooled

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Standard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW Medium Voltage Product Overview MVB SERIES, MEDIUM VOLTAGE DRAW-OUT CIRCUIT BREAKER MVB SERIES Standard Breaker Features : 1200, 2000, 3000 Amps, 3 phase, 60

More information

CENTERLINE 2100 Low Voltage Motor Control Centers

CENTERLINE 2100 Low Voltage Motor Control Centers Installation Instructions Original Instructions CENTERLINE 2100 Low Voltage Motor Control Centers Bulletin Numbers 2100 Important User Information Read this document and the documents listed in the additional

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1 GE 8000-Line -1 Mains, coming Lines MAINS GENERAL Main units consist of an externally operable circuit disconnect, either a fusible switch or a circuit breaker. Sizes by ampere rating, short-circuit rating,

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

825-P Modular Protection System for motors Specification Guide

825-P Modular Protection System for motors Specification Guide Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7 Construction Standards Page 1 of 7.1 General.1 New buildings are to be provided with an indoor unit substation designed to accept 15kV and 25kV primary voltages, however, the primary voltage connected

More information

CENTERLINE 1500 Medium Voltage Motor Control Centers

CENTERLINE 1500 Medium Voltage Motor Control Centers Selection Guide CENTERLINE 1500 edium Voltage otor Control Centers Designed for Intelligence, Safety, and Reliability CENTERLINE 1500 otor Control Centers edium Voltage otor Control Centers... 3 Standard

More information

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H) 2101 Commonwealth Blvd, Suite B Ann Arbor, MI 48105-5759 www.med.umich.edu/facilities/plan/ 263010-H: SUPPLEMENTAL PARALLELING GEAR (16315-H) Related Sections Basis Guideline: N/A For an explanation of

More information

Installation Instructions For Motor Control Center (MCC) Units

Installation Instructions For Motor Control Center (MCC) Units s Page 1 of 8 Installation Instructions December, 2013 Installation Instructions For Motor Control Center (MCC) Units Hazardous voltage. Will cause death or serious injury. Always de-energize and ground

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

These documents contain additional information concerning related products from Rockwell Automation.

These documents contain additional information concerning related products from Rockwell Automation. Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Title PowerFlex 0-Series Drive Installation Instructions PowerFlex 0-Series Programming

More information

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage Switchgear Low Voltage Introduction...13-1 AKD-10 Low-Voltage Switchgear...13-3 AKD-20 Low-Voltage Switchgear...13-3 Low Voltage Switchgear GE low-voltage switchgear is heavy-duty equipment built to ANSI

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

Kinetics Industries Inc. 140 Stokes Ave. Trenton, NJ Fax

Kinetics Industries Inc. 140 Stokes Ave. Trenton, NJ Fax Kinetics Industries Inc. 140 Stokes Ave. Trenton, NJ 08638 609-883-9700 609-883-0025 Fax Common optional features include: AC main line contactor, DC undervoltage and / or undercurrent relay, regenerative

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings

More information

Waterlogix uses an OPLC which is an Operator Interface and PLC built into one low cost unit

Waterlogix uses an OPLC which is an Operator Interface and PLC built into one low cost unit Fountain LA Page 1 Waterlogix Tuesday, August 31, 2010 6:11 AM Waterlogix is a customizable Off the Shelf solution for automated Water Features Design and Manufactured by UL Listed General Control Systems,

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

CUSTOMIZED OPTIONS FOR 1-WEEK DELIVERY

CUSTOMIZED OPTIONS FOR 1-WEEK DELIVERY IN STOCK GUARANTEED! Benshaw is offering the most Rugged, Reliable and Proven soft starter for your most demanding and tough applications CUSTOMIZED OPTIONS FOR 1-WEEK DELIVERY A Regal Brand 2017 Information

More information

Industry Automation Control Components

Industry Automation Control Components Industry Automation Control Components SIRIUS 3RV2 Motor Starter Protectors SIRIUS 3RV21 Motor Starter Protectors can be easily and flexibly combined with other SIRIUS devices to reduce space requirements

More information

Intelligent Choice for Prestigious Buildings

Intelligent Choice for Prestigious Buildings Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6

More information

NS Feeder pillar up to 3200A

NS Feeder pillar up to 3200A NS Feeder pillar up to 3200A Advanced technology for low voltage, outdoor distribution Merlin Gerin Modicon Telemecanique Outdoor electrical distribution with advanced technology Merlin Gerin low voltage,

More information

PowerFlex 6000 Medium Voltage AC Drives

PowerFlex 6000 Medium Voltage AC Drives PRELIMINARY INFORMATION PowerFlex 6000 Medium Voltage AC Drives Simple. More Reliable. Easy-to-use. User-friendly Control for Variable and Constant Torque Applications Cost-effective solutions for new

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

AME. Rectifier - Battery charger. Industrial applications: Key features:

AME. Rectifier - Battery charger. Industrial applications: Key features: Rectifier - Battery charger AME VRLA batteries, flooded battery or Ni/Cd with output voltage from 24, 48, 110, 220 Vdc up to 150A Industrial applications: Oil&Gas (Petrochemicals Offshore, Onshore, Pipelines);

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Model 6 Motor Control Centers Catalog 8998CT9701R07/ Class 8998

Model 6 Motor Control Centers Catalog 8998CT9701R07/ Class 8998 Catalog 8998CT9701R07/09 2009 Class 8998 CONTENTS Description............................................. Page Product Description.......................................... 7............................

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Relays.................... C440/XT Electronic

More information

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear 13 Low Voltage Switchgear Siemens Type WL low voltage metal-enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of

More information

152H F480 F BD B 59 8B

152H F480 F BD B 59 8B ulletin Catalog Number Explanation Open and Non-Combination F F D L a ulletin Number Solid-State Controller F F F F F F F F F F F F F F F F Combination H H F F F F F F F F F F F F F F Enclosed Solid-State

More information

IEC Starter Approximate Dimensions

IEC Starter Approximate Dimensions Technical Data IEC Starter Approximate Dimensions Bulletin Numbers 103H/107H/140M, 103-C/107/C, 105, 109, 106, 112, 113, 190E/191E, 190S/191S, 103S/107S, 103T/107T Topic Page Enclosed Starters and Motor

More information

POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers

POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers Class 6037 CONTENTS Schneider Electric Brands Description Page Product Description..................................................

More information

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI BHARAT HEAVY ELECTRICALS LIMITED, JHANSI DESIGN, MANUFACTURING, TESTING, SUPPLY INSTALLATION AND COMMISSIONING OF 11KV VACUUM CIRCUIT BREAKER NOTE : 1 VENDOR must submit complete information against clause

More information

ROBICON W120 enclosed drive

ROBICON W120 enclosed drive SINAMICS Drives ROBICON W120 enclosed drive 1 HP to 200 HP Introduction This technical data sheet provides a short overview of the most important characteristics of the ROBICON W120 enclosed standard 6-pulse

More information

BETA Low-Voltage Circuit Protection

BETA Low-Voltage Circuit Protection BETA Low-Voltage Circuit Protection /2 Introduction Miniature Circuit Breakers /4 5SP and 5SY miniature circuit breakers / 5SJ6...-.KS miniature circuit breakers with plug-in terminal /21 5SY6 0 miniature

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

Size for Size Best Value in the Industry

Size for Size Best Value in the Industry Size for Size Best Value in the Industry Overview for SMC -Flex and SMC -3 Soft ers 3...480A 200-460VAC...500-575VAC www.klinkmann.com Allen-Bradley Smart Motor Controllers... Providing Unmatched Intelligent

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

PowerFlex Digital DC Drive

PowerFlex Digital DC Drive Technical Data PowerFlex Digital DC Drive Table of Contents Topic Page Additional Resources 3 Product Description 3 Standard Drives Program 4 Catalog Number Explanation 6 Standard Drives Product Selection

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

Bulletin 150 SMC Flex Smart Motor Controllers Product Overview/Modes of Operation/Features

Bulletin 150 SMC Flex Smart Motor Controllers Product Overview/Modes of Operation/Features Bulletin Product Overview/Modes of Operation/Features Bulletin SMC Flex Smart Motor Controller The SMC Flex controller provides microprocessor controlled starting for standard -phase squirrel-cage induction

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

SDS Enclosed Star-Delta Starter User Guide

SDS Enclosed Star-Delta Starter User Guide SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING

More information

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011 Page 1 of 6 STANDARD SPECIFICATION FOR LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs Rev No. Issue Date Pages Rev Description Prepared By Checked By Approved By 0 15.07.2008 6 Issued for FEED MSJ VDV VDV

More information

Typical Specification

Typical Specification Engineered to Order Built to Last Typical Specification VAULT VRPFI, TWO POSITION, ROTARY PUFFER SWITCHGEAR PART 1- GENERAL 1.1 DESCRIPTION A. The switch shall consist of manually operated load interrupting,

More information

Phone: Fax: Web:

Phone: Fax: Web: Description Wide rated operational voltage 208 690 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 30 to 1050 A (Up to 1810 A inside delta) Wide ambient temperature

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

Softstarters Softstarters

Softstarters Softstarters , PSS & PST(B), PSS & PST(B) Low Voltage Products & Systems 6.1 General information PSR PSS From the moment the first electrical motors appeared, engineers have been searching for a way to avoid electrical

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

WELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A

WELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A WELCOME TO THE WORLD OF COMPLETE AUTOMATION Innovative MCS Starter Solutions MCS Starters and the New Mounting System 141A Welcome to the Wide World of Allen-Bradley Starters Innovative solutions for state

More information

VS1PFB 230V, 50/60 Hz, 3-Phase

VS1PFB 230V, 50/60 Hz, 3-Phase Farm Duty Unit Handling Brake 200 & 575 Volt Pump and Fan Bypass AC Drive 7.5 thru 40 Hp 7.5 thru 125 Hp & Controls 230 VAC 460 VAC 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications: Pump and Fan AC Drive

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

Petrochemical processing Ship Yards Oil Fields Irrigation

Petrochemical processing Ship Yards Oil Fields Irrigation TITAN is your solution When you have demanding three phase power requirements and when need a phase conversion system that is up to the challenge you need the TITAN. Whether you re powering a single Machine

More information

Manual motor starters Overview and benefits

Manual motor starters Overview and benefits Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection

More information