Pump Panel Specifications
|
|
- Jason Hancock
- 5 years ago
- Views:
Transcription
1 Technical Data Pump Panel Specifications Bulletin Numbers 13 and 133 Topic Page Specifications Electrical Ratings (Bulletins 13, 13X, 133, 133X) Mechanical Ratings (Bulletins 13, 13X, 133, 133X) 3 Construction (Bulletins 13, 13X, 133, 133X) 3 Environmental (Bulletins 13, 13X, 133, 133X) 3 Short Circuit Rating 4 Approximate Dimensions Type 3R (Enclosure Code "N") Rainproof. Enclosures Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Contactor and Starter Specifications, publication 00-TD0 Industrial Automation Wiring and Grounding Guidelines, publication Product Certifications website, Description Provides specifications for Bulletin 00 product lines. Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details. You can view or download publications at To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
2 Specifications Electrical Ratings (Bulletins 13, 13X, 133, 133X) 1 Load Voltage Continuous Current Rating Service Limit Current Rating (1) Maximum Hp Rating (Nonplugging and Non-jogging Duty) Maximum Hp Rating (Plugging and Jogging Duty) () Transformer Primary Switching kva Rating (Inrush Current 0 Times Continuous Current) Transformer Primary Switching kva Rating (Inrush Current = 0 40 Times Continuous Current) Capacitor Switching kvar (3) Maximum Circuit Closing Inrush Current [A] Peak Including Offset [V] [A] [A] / 7-1/ / 1 7-1/ / / (1) Service-Limit Current Ratings The service-limit current ratings that are shown represent the maximum rms current, in amperes, which the controller is permitted to carry for protracted periods in normal service. At servicelimit current ratings, temperature rises are permitted to exceed those obtained by testing the controller at its continuous current rating. The current rating of overload relays or the trip current of other motor protective devices that are used, should not exceed the service-limit current rating of the controller. () Plugging or Jogging Service The listed horsepower ratings are recommended for those applications requiring repeated interruption of stalled motor current that is encountered in rapid motor reversal in excess of five openings or closings per minute and should not be more than ten in a ten minute period. (3) If maximum available current (at capacitor terminals) is greater than 00 A, contact your local Rockwell Automation Sales Office, Allen-Bradley Distributor, or ICS- Standard. Rockwell Automation Publication 13-TD001A-EN-P - March 017
3 Mechanical Ratings (Bulletins 13, 13X, 133, 133X) Mechanical Life (Millions of Operations) Maximum Number of Auxiliary Contacts Pick-up (Average) Operating Time [ms] Drop-out (Average) Construction (Bulletins 13, 13X, 133, 133X) Wire for Power Terminals Required Torque on Power Terminal Wire Clamps and Pressure Connectors or Lugs Type of Power Terminal 1 # 8 AWG 0 lb in Saddle or wire clamps # 4 AWG 4 lb in 3 #8 1/0 AWG 10 lb in 4 # 4/0 AWG 7 lb in #4 AWG 00 MCM 37 lb in Pressure terminals Lugs sold separately Contact Material Power Contacts Auxiliary Contacts Silver alloy Silver Requirements for Sizing of Wire All wire rated 17 F (7 C) or higher must be sized per the local Electrical Code for 17 F (7 C) wire. Environmental (Bulletins 13, 13X, 133, 133X) Operating Position Operating Temperature Range Altitude Corrosion- Resistance 1 3 Vertical 4 Horizontal Starters with eutectic alloy overload relay F ( + C) Starters with solid-state overload relay F ( + C) (provided condensation is prevented) 000 feet before derating All metal parts are treated for corrosion-resistance Rockwell Automation Publication 13-TD001A-EN-P - March 017 3
4 Short Circuit Rating Combination contactors and starters with disconnect switch: Bulletins 13X and 133X Combination Contactors and Starters with Disconnect Switch: Bulletin 13X Fuse Type Available Short Circuit Amperes RMS Symmetrical [A] 0 3 H, K H, K J, R L Combination Contactors and Starters with Circuit Breaker: Bulletin 133X Enclosure Type 3R 3R Available Short Circuit Amperes RMS Symmetrical [A] Maximum Voltage [V] 00 Maximum Voltage [V] Bulletins: Bulletins: 13C, 13F Bulletins: 13S, 133S Thermal Magnetic Breaker Fusible Disconnect Thermal Magnetic Breaker Rockwell Automation Publication 13-TD001A-EN-P - March 017
5 Approximate Dimensions Approximate dimensions are shown in inches (millimeters). Dimensions are not intended for manufacturing purposes. Bulletins 13, 13C, 13D, 13F, 13S, 13X, 133, 133C, 133D, 133F, 133S, 133X Type 3R (Enclosure Code "N") Rainproof. Enclosures E B A 1,, 3, 4,, 7 Bulletin No. A Height B Width C Depth Approximate Dimensions in Inches (Millimeters) D Mounting E Mounting F Mounting G Handle Depth H J Approximate Shipping Weight [lb (kg)] 13D, 133D all contact factory for information 13, (98). (7) 8. () 8.88 (733) () 7 (178). (1) 9.7 (7) 40 (18.) 13X, 133X , A (7) 0. (1) 8.7 (1) (88) (4) (4). (1) 3.38 (94) 90 (40.8) 13X, 133X A 0 (170) (9) 9.90 (1) 4.88 (1394) 1. (387) 1. (387). (1).38 (3) 0 (113.4) 13X, 133X 133X 13S, 133C, 133F, 133S 13X (1) 01 A 1 31 A () 0 (14). (77) (949) () 1 (40).8 (18) 9.8 (179.9) 11 (79) 11 (79) (80) 40.7 (34) 7. (194) 7. (194) 9.8 (4) 9.8 (4) 30 (13.3) 40 (190.) 13X, 133X A 84 (134) 39. (03) 18 (47) 93.8 (379.) 11 (79) 4.84 (88) 7. (194) 9.8 (4) 0 (94.8) (1) Fusible disconnect switch with Class R fuses. () s 1 and have one top-mounting hole that is located on the center line. All sized in large enclosures have two top mounting holes that are located as shown. Rockwell Automation Publication 13-TD001A-EN-P - March 017
6 Approximate dimensions are shown in inches (millimeters). Dimensions are not intended for manufacturing purposes. Bulletins 13, 13C, 13D, 13F, 13X, 133, 133C, 133D, 133F, 133X Type 3R (Enclosure Code "N") Rainproof Enclosures Approximate Dimensions in Inches (Millimeters) Bulletin No. N P R T Inside Outside Inside Outside Inside Outside Inside Outside 13D, 133D all contact your local Rockwell Automation sales office for information 13, 13X, 133, 133X 1 43 A 1-3/8 (3) 1 in. Hub 1-3/3 (44) 1-1/4 in. Hub 1-3/3 (44) 1-1/4 in. Hub 1-31/3 (0) 1-13, X, 133X A 1-31/3 (0) 1- -1/3 (3) in. Hub 1-3/8 (3) 1 in. Hub 1-31/3 (0) 1-1-3/8 (3) 1 in. Hub 1-3/3 (44) 1-1/4 in. Hub 13X, 133X 01 A 1-31/3 (0) 1- -1/3 (3) in. Hub 1-31/3 (0) 1- -1/3 (3) in. Hub Bulletin No. Approximate Dimensions in Inches (Millimeters) U V W Inside Outside Inside Outside Inside Outside 13D, 133D all contact your local Rockwell Automation sales office for information 13, 13X, 133, 133X 1 43 A 13, X, 133X A 13X, 133X 01 A 1-31/3 (0) 1-3 (7) - -1/3 (3) in. Hub 3-/8 (9) 3 in. Hub 3 (7) - 3 (7) - 3 (7) - 3-/8 (9) 3 in. Hub Rockwell Automation Publication 13-TD001A-EN-P - March 017
7 Notes: Rockwell Automation Publication 13-TD001A-EN-P - March 017 7
8 Rockwell Automation Support Use the following resources to access support information. Technical Support Center Local Technical Support Phone Numbers Direct Dial Codes Literature Library Product Compatibility and Download Center (PCDC) Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates. Locate the phone number for your country. Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer. Installation Instructions, Manuals, Brochures, and Technical Data. Get help determining how products interact, check features and capabilities, and find associated firmware Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at Rockwell Automation maintains current product environmental information on its website at Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat: 347 İçerenköy, İstanbul, Tel: +90 (1) Publication 13-TD001A-EN-P - March 017 Copyright 017 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
1494U Visible-Blade Disconnect Switch
Selection Guide 1494U Visible-Blade Disconnect Switch Bulletin Number 1494U What s Inside Contents Page 1494U Disconnect Switch Components 3 1494U Disconnect Switch Accessories 4 1494U Disconnect Switch
More informationPreventive Maintenance Checklist of Industrial Control and Drive System Equipment
Service Bulletin Preventive Maintenance Checklist of Industrial Control and Drive System Equipment Use the following checklist as a guide in performing preventive maintenance. ATTENTION: Servicing energized
More informationIEC Starter Approximate Dimensions
Technical Data IEC Starter Approximate Dimensions Bulletin Numbers 103H/107H/140M, 103-C/107/C, 105, 109, 106, 112, 113, 190E/191E, 190S/191S, 103S/107S, 103T/107T Topic Page Enclosed Starters and Motor
More informationApplying More Than One ArmorStart Motor Controller in a Single Branch Circuit on Industrial Machinery
Application Guide Applying More Than One ArmorStart Motor Controller in a Single Branch Circuit on Industrial Machinery Bulletin Numbers 280, 281, 284, 290, 291 Topic Introduction 2 Background 2 ArmorStart
More informationMP-Series Electric Cylinders Replacement Parts (Series B and C)
Installation Instructions Original Instructions MP-Series Electric Cylinders Replacement Parts (Series B and C) Catalog Numbers MPAR-NA3210C, MPAR-NA323C, MPAR-NA4012C, MPAR-NA405C, MPAR-NA6310C, MPAR-NA6320C
More informationMP-Series (Series A and B) and TL-Series Electric Cylinders Replacement Parts
Installation Instructions Original Instructions MP-Series (Series A and B) and TL-Series Electric Cylinders Replacement Parts Catalog Numbers MPAR-NA3210C, MPAR-NA323C, MPAR-NA4012C, MPAR-NA405C, MPAR-NA6310C,
More informationControl and Load Switch Specifications Bulletin Number 194E, 194L
Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13
More informationKinetix 5700 Capacitor Modules
Installation Instructions Kinetix 5700 s Catalog Numbers 98-CAP-40, 98-CAP-DCBUS-IO Topic Page About the s Before You Begin Install the s Connector Data 6 Wiring Requirements 8 Additional Resources Summary
More informationBattery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions
Installation Instructions Original Instructions Battery Replacement Catalog Number 2711P-RY2032 Topic Page Summary of Changes 1 Important User Information 2 Precautions 3 About This Publication 2 Replace
More informationSpare Allen-Bradle. Battery Replacement. Installation Instructions. About This Publication. Catalog Number 2711P-RY2032
Installation Instructions Battery Replacement Catalog Number 2711P-RY2032 Topic Page Important User Information 2 Precautions 3 Replace the Battery in PanelView Plus Terminals 3 Replace the Battery in
More informationE300 Electronic Overload Relay
Quick Start Original Instructions E300 Electronic Overload Relay Bulletins 193, 592 Important User Information Read this document and the documents listed in the additional resources section about installation,
More informationSelection Guide. PowerFlex Digital DC Drive
Selection Guide PowerFlex Digital DC Drive PowerFlex Digital DC Drive The PowerFlex DC drive combines powerful performance with flexible control to produce a highly functional, cost effective drive and
More information1321 Power Conditioning Products
Technical Data 1321 Power Conditioning Products Don t Ignore the Cost of Power Line Disturbance Topic Page Product Overview 2 1321-3R and 3RA Series Line Reactors 3 1321 Reflective Wave Reduction (RWR)
More informationCENTERLINE 2500 Low Voltage Motor Control Centers and Power Distribution Gear Catalog Structure Breakdown
Technical ata CENTERLINE 2500 Low Voltage Motor Control Centers and Power istribution Gear Catalog Structure Breakdown Catalog Numbers 2500 Table of Contents Topic Page Additional Resources 2 Ordering
More informationKinetix 350 Single-axis EtherNet/IP Servo Drives
Installation Instructions Kinetix 350 Single-axis EtherNet/IP Servo Drives Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM, 2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM,
More informationKinetix VP Food Grade Servo Motors with mm Frame Size
Installation Instructions Original Instructions Kinetix VP Food Grade Servo s with 063 165 mm Frame Size Catalog Numbers VPF-A0632, VPF-A0633, VPF-A0752, VPF-A0753, VPF-A1001, VPF-A1002, VPF-A1003, VPF-A1153,
More informationKinetix 350 Single-axis EtherNet/IP Servo Drives
Installation Instructions Kinetix 350 Single-axis EtherNet/IP Servo Drives Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM, 2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM,
More informationSMC Dialog Plus Specifications
Technical Data MC Dialog Plus pecifications Bulletin Number 150 Topic Page Product Overview 2 tandards Compliance and Certifications 2 Modes of Operation 3 Features 5 Catalog Number Explanation 6 General
More information[V] Common Control Transformer Control (See page 1-78 Note)
Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state
More informationInstallation Instructions
Installation Instructions Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Operating Mechanisms For use with Circuit Breakers 140G-G, 140MG-G, 140G-H, 140MG-H, 140G-I, 140MG-I, 140G-J, 140MG-J,
More informationCENTERLINE 2100 Motor Control Centers
TECHNICAL DATA CENTERLINE 2 Motor Control Centers Instantaneous Trip Motor Circuit Protectors (MCP) in Combination NEMA Starter, Soft Starter (SMC) and Variable Frequency AC Drive Units 1A Frame Instantaneous
More informationCENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies
Selection Checklist CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Use this checklist to help you configure your CENTERLINE 2500 Motor Control Center. You can type in the fields
More informationDisconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494
Technical ata isconnect Switch and ircuit reaker Mechanism Specifications ulletin Number 1494 Topic Page 1494U isconnect Switch Specifications 2 1494, 1494F, 1494G, 1494R, 1494V isconnect Switch Specifications
More informationSMC -50 Technology and Control Advances
White Paper SMC -50 Technology and Control Advances Sensorless Linear Acceleration and Energy Management Topic Page Introduction 2 Energy Effectiveness with Appropriate Starting Method 3 SMC-50 Starting
More informationMounting System Specifications
Technical Data Mounting ystem pecifications Bulletin Number 141A Topic Page Cat. No. Explanation 2 General pecifications 4 Approximate Dimensions 7 Additional Resources These documents contain additional
More informationCapacitor-based DC Uninterruptible Power Supplies
Reference Manual Original Instructions Capacitor-based DC Uninterruptible Power Supplies Catalog Numbers 1606-XLSCAP24-6, -XLSCAP24-12 Important User Information Read this document and the documents listed
More informationThe Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller
The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the
More informationAllen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500
Installation Instructions CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns Catalog Number 2500 Topic Page Important User Information 2 Location Planning 3 Environment 3 Removal
More informationCable-Operated Disconnect Switches. Accessories
Cable-Operated Disconnect Switches Accessories Description For Use With Auxiliary Contacts 1 N.O. Contact 1494C, 1494F, 1494V, and 1494G ( 1495-N8 1 N.O. Contact (low-level switching) A) Disconnect Switches
More information1489-M Circuit Breakers
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationNEMA Full Voltage Power Devices. Section 1. Control Catalog 1-1
NEMA Rated Full Voltage Power Devices Application Information and Technical Data (300-Line)...-4 Magnetic Nonreversing Starters (CR306, CR386) Basic Features (300-Line) and Technical Features (CR306, CR386)...-7
More informationTransfer switch OTEC open or delayed transition
Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.
More informationFeeder Circuit Breaker Units Secure Support Pan and Change Door Latch
Installation Instructions Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch Catalog Numbers 2193FZ Topic Page About This Publication 1 Required Tools 1 Important User Information 2
More informationApplications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders
Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000
More informationUsing an SMC-50 Solid-State Smart Motor Controller for Pump Protection
Using an SMC-50 Solid-State Smart Motor Controller for Pump Protection William Bernhardt and Richard Anderson, Rockwell Automation Pump system protection comes in many methods, from preventing water hammer
More informationSED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options
SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options Product Description The SED2 Electronic Bypass (E-Bypass) Options are companion packages for the family of SED2 Variable Frequency Drives
More informationGeneral technical data. Ambient conditions
Data sheet Overload relay 9...12 A For motor protection Size S00, Class 10 Contactor mounting Main circuit: screw terminal Auxiliary circuit: screw terminal Manual-Automatic-Reset!!! Phased-out product!!!
More informationCONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name
Product data sheet CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION General technical data: product brand name Size of contactor Protection class IP / on the front SIRIUS S00
More informationCONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name
Product data sheet CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION General technical data: product brand name Size of contactor Protection class IP / on the front
More informationFor Options, Modifications and Accessories, see pages Discount Schedule A6
Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F
More informationTDX - Taco Duplex Starter with
Energy Management TDX - Taco Duplex Starter with Smartstart The TDX extends the life of your pumps by alternating control. It comes standard with underload protection, a enhanced class 10 electronic overload
More informationT300MVi JK OEM POWER CELLS MEDIUM VOLTAGE VACUUM CONTACTOR. Reliability in motion. Reliability in motion
MEDIUM VOLTAGE VACUUM CONTACTOR T300MVi JK OEM POWER CELLS Reliability in motion Reliability in motion 400 AMPERE AT 2300-6600 VOLTS (7200 VOLT MAX) DRAWOUT AND FIXED APPLICATIONS JK OEM PART NUMBER DESCRIPTION
More informationEnclosed Starter Selection Guide. Featuring Snap-together Wiring Technology
Enclosed Starter Selection Guide Featuring Snap-together Wiring Technology Enclosed Starter Wiring Made Easy How It Works Component wiring is color-coded by function. The wiring sleeve cover corresponds
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationPRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V
PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationMedium Voltage Drive Harmonic Filter and Power Factor Correction Units. User Manual. Bulletin volts hp
Medium Voltage Drive Harmonic Filter and Power Factor Correction Units User Manual Bulletin 1519 2300-4160 volts 250-3500 hp Important User Information Read this document and the documents listed in the
More informationOTEC Transfer switch open transition
Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator
More informationSubmittal Data Information
Effective: NOVEMBER 3, 2014 JOB CONTRACTOR ITEM NO. Submittal Data Information TDX - Taco Duplex Starter ENGINEER REP. 301-2693 Supersedes: NEW TDX - TACO DUPLEX STARTER 1Ø, 230V, 1/10-15HP 3Ø, 200-460V,
More information3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,
Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,
More informationElectronic overload relays EF205 and EF370
Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationA. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.
16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional
More informationMS General Information Extended Product Type: MS
MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual
More informationHigh Frequency SineWave Guardian TM
High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation
More informationApplication Techniques. North American Standards, Configurations, and Ratings: Introduction to Motor Circuit Design
Application Techniques North American Standards, Configurations, and Ratings: Introduction to Motor Circuit Design Important User Information Solid-state equipment has operational characteristics differing
More informationSeries A Construction
Page 1 of 7 Knowledgebase Technote ID # Q18363 9/2/2003 505 Series A Construction 505 505 1495-F1 (1 N.O. auxiliary contact) 1495-G5 (1 N.C. early break auxiliary contact) 1495-H0 ( 1 N.C. late break auxiliary
More information150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz
Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More informationHp V AC Current Rating [A] 230V AC 60 Hz
Product Selection/Options Open Type Controllers Up to V AC kw Hp V AC Current Rating [A] V AC Hz V AC Hz V AC Hz V AC Hz V AC Hz / Hz Control V AC/DC Control.. -BNBD -BNBR. -BNBD -BNBR -BNBD -BNBR -BNBD
More informationIntroduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction
Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationMotor Protection. Presented By. Scott Peele PE
Motor Protection Presented By Scott Peele PE Motor Protection Overload on the motor load Fuses Heater Magnetic relay Short Circuit on motor circuit Fuses Breakers Single Phasing Overload Protection NEC
More information1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters
.2 Type S80+, Soft Starters Contents Description Type S6, Solid-State Soft Starters........... Type S80+, Soft Starters Operation............................. Features.............................. Benefits...............................
More informationA. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:
SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification
More informationBulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers
Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled
More informationExample Maintenance Schedule 1. The attached document is an example of an acceptable maintenance schedule.
IRRIGATION TRAINING & RESEARCH CENTER California Polytechnic State University San Luis Obispo, CA 93407-0730 Phone: 805.756.2434 FAX: 805.756.2433 www.itrc.org Example Maintenance Schedule 1 The attached
More informationDirect On Line (DOL) Motor Starter. Direct Online Motor Starter
Direct On Line (DOL) Motor Starter Direct Online Motor Starter Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting.
More informationApplication Description
-14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....
More information300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds
Digital Soft Start Controls 9 thru 900 Amps 208-460V 50/60 Hz. 9 thru 900 Amps 208-575V 50/60 Hz. Applications: Controlled ramp start and stop, minimize spillage in material handling, reduced water hammer
More informationControl Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD
Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control
More informationDesign Standard. Purpose: Design Standard:
Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard
More informationSineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING
SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationSectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications
Sectionalizing Rick Seeling Introduction Philosophy Pete Malamen Three Phase Reclosers High-Side Protection Specific Applications History Early 1970 s Small Substation Transformers
More informationSMC Flex Specifications
Technical Data MC Flex pecifications ulletin Number 50 Topic Page Product Overview 2 tandards Compliance and Certifications 2 Features 3 Catalog Number Explanation 4 General pecifications 6 Approximate
More informationNEMA Contactors & Starters (Freedom)
Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1
More informationCL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES
SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as
More informationTransfer switch OTEC and OTECSE open transition
Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationMOTOR TERMINAL CONNECTIONS
MOTOR TERMINAL CONNECTIONS Motor Classification Most of the industrial machines in use today are driven by electric motors Motors are classified according to the type of power used (AC or DC) and the motors
More informationFuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A
DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low
More informationECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9
February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR
More informationBulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents
Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures
More informationTypes of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:
Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.
More informationV AC, 50/60 Hz 150-F251NCD 150-F251FCD 24V AC/DC 150-F5NCR
Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, Type /) Controllers For use with Line-Connected Motors, Continued Enclosures other than those listed are available; consult your local
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides
More information3.2. Current Limiting Fuses. Contents
.2 Contents Description Current Limiting Applications................. Voltage Rating.......................... Interrupting Rating....................... Continuous Current Rating................ Fuse
More informationTO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control
CEP7 Solid-State Overload Relay for Motor Control Centers and Technical Data Description Page Product Description.............................................. 2 Specifications...................................................
More informationOverview. Contents. Overview
1/0 Overview 1 Contents Overview 3-pole Block Contactors and Motor Protection... 1/ 4-pole Block Contactors... 1/3 Contactors for Specific Applications... 1/4 Mini Contactors and Motor Protection... 1/
More informationSelection and application guide
Selection and application guide Integrated Power Systems Switchboards www.usa.siemens.com/switchboards Integrated Power Systems Switchboards Contents General Product Information 2-3 General Layout Information
More informationBulletin 505 Full Voltage Reversing
Bulletin 505 Full Voltage Reversing Contactor Accessories Bulletin 500DC Electronic DC Coil Controller Compact size NEMA sizes 0 3 Versatility Fully assembled unit or as a retro fit kit Features LED status
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements
More informationDC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data
DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data Table of Contents 1370 DC Loop Contactors....................................3 Catalog Number Explanation...............................3
More information