Kinetix 5700 Capacitor Modules
|
|
- Veronica Woods
- 6 years ago
- Views:
Transcription
1 Installation Instructions Kinetix 5700 s Catalog Numbers 98-CAP-40, 98-CAP-DCBUS-IO Topic Page About the s Before You Begin Install the s Connector Data 6 Wiring Requirements 8 Additional Resources Summary of Changes Active shunt catalog numbers were added to the table on page 9. About the s The 98-CAP-40 capacitor module and 98-CAP-DCBUS-IO extension module are used for energy storage and to extend the DC-bus voltage to another inverter cluster. The 98-CAP-40 capacitor module is used in applications with up to 00 A maximum external DC-bus current. You can add the 98-CAP-DCBUS-IO extension module to the left or right of the capacitor module when the external DC-bus current exceeds 00 A, up to a maximum of 00 A. See the Kinetix 5700 Servo Drives User Manual, publication 98-UM00, for detailed information on wiring, applying power, and troubleshooting. Before You Begin Remove all packing material, wedges, and braces from within and around the components. After unpacking, check the item nameplate catalog number against the purchase order. The Kinetix 5700 capacitor modules include the following accessory items. Item 98-CAP CAP-DCBUS-IO Parts kit containing stud/lug cover with wires (), lug-cover bottom plate, hex nuts and spacers for M8 studs, and 55 mm DC-bus link X X Wiring plug for the module status (MS) connector X Wiring plug for the 4V DC input power (CP) connector X Flexible bus bars, each X () Stud cover for systems without wires attached is installed on each module.
2 Kinetix 5700 s Install the s These procedures assume that you have prepared your panel, mounted your Kinetix 5700 servo drives, and understand how to bond your system. For installation instructions regarding equipment and accessories not included here, refer to the instructions that came with those products. SHOCK HAZARD: To avoid the hazard of electrical shock, perform all mounting and wiring of the Kinetix 5700 drive modules prior to applying power. Once power is applied, connector terminals can have voltage present even when not in use. ATTENTION: Plan the installation of your system so that you can perform all cutting, drilling, tapping, and welding with the system removed from the enclosure. Because the system is of open type construction, be careful to keep any metal debris from falling into it. Metal debris or other foreign matter can become lodged in the circuitry, which can result in damage to components. Zero-stack Tab and Cutout Engaging the zero-stack tab and cutout from module-to-module is required for shared-bus drive systems and includes the Kinetix 5700 capacitor modules. This is done to make sure that the module connectors are spaced properly to accept the shared-bus connection system. Zero-stack Tab and Cutout Example Zero-stack Tab and Cutout Engaged 98-xxxx-ERS3 Inverter 98-Pxxx DC-bus Power Supply (front view) DC BUS 98-CAP-40 (front view) Mount the s Clearance requirements below the Kinetix 5700 capacitor and extension modules are identical to the drive modules, however, additional space is required above for access to the DC-bus studs and side-to-side for the DC-bus wiring that attaches to the studs. Refer to the Kinetix 5700 Servo Drives User Manual, publication 98-UM00, for additional mounting information. Rockwell Automation Publication 98-IN008C-EN-P - April 07
3 4 I/O 5 0 I/O-A I/O-B I/O-A 6 I/O-B UFB MF ULE I/O-A 6 I/O-B I/O-A I/O-B I/O-A 6 I/O-B I/O-A 6 I/O-B ULE Kinetix 5700 s You can mount the 98-CAP-40 capacitor module on the far right or far left of any system cluster, depending on the input power configuration. More than one capacitor module can be used in a cluster, if needed. Each additional module adds to the total system capacitance and increased energy storage. The 98-CAP-DCBUS-IO extension module is always mounted next to a capacitor module and always on the outside of the system cluster (either first or last). An extension module is needed if the external DC-bus current is greater than 00 A, up to a maximum of 00 A. IMPORTANT Capacitor modules always mount on the far right or far left of the system cluster, which ever configuration makes the best use of panel space. Extension modules always mount next to a capacitor module and on the outside of the cluster, (first or last) in systems up to a maximum of 00 A. Inverters with the highest power ratings must be positioned closest to the DC-bus supply (in decreasing order) and only two clusters are allowed on the same DC-bus. Kinetix 5700 Drive System Example with Extended (00 A) Drive System DC-bus Power Supply High-to-low Power Rating Single-axis Inverter Dual-axis Inverters System Cluster I/O 6 98-CAP-DCBUS-IO Extension Module 98-CAP-40 MBRK + - High-to-low Power Rating Dual-axis Inverters Extended System, Cluster In this example, the capacitor module and extension module are positioned on the far right in both clusters. 98-CAP-DCBUS-IO Extension Module However, other configurations are possible, as long as the inverters with the highest power ratings (in each cluster) are positioned closest to the DC-bus power supply and in decreasing order leading away from the supply. 98-CAP-40 For extended 00 A drive systems, remove the 98-CAP-DCBUS-IO extension modules. Rockwell Automation Publication 98-IN008C-EN-P - April 07 3
4 4 I/O READY FAULT PROGRAM RST PRG REGENERATIVE REGENERATIVE POWER SUPPLY 5 0 ENT A V kw I/O-A I/O-B I/O-A 6 I/O-B UFB MF ULE DC BUS ULE DC BUS ULE ULE DC BUS I/O I/O-A I/O-B I/O-A 6 I/O-B UFB MF I/O-A 6 I/O-B I/O-A I/O-B I/O-A 6 I/O-B Kinetix 5700 s Kinetix 5700 Drive System Example with RPS Unit (00 A) Drive System 870MC-RPS90BM Regenerative Power Supply High-to-low Power Rating Single-axis Inverter Dual-axis Inverters 870 MC MC 98-CAP-DCBUS-IO Extension Module MBRK CAP-40 In this example, the 870MC-RPS unit, capacitor module, and extension module are positioned on the far left, with the DC-bus supply feeding into the inverter with the highest power rating. To move the DC-bus input voltage to the far right, you must also reverse the order of the inverters, so the inverters with the highest power ratings are positioned closest to the DC-bus supply and in decreasing order leading away from the DC-bus supply. For an RPS unit in 00 A systems (catalog number 870MC-RPS065BM), remove the 98- CAP-DCBUS-IO extension module. Kinetix 5700 Drive System Example with Multiple s DC-bus Power Supply Single-axis Inverter Dual-axis Inverters 98-CAP-40 s I/O 6 In this example, the bank of three capacitor modules are positioned on the far right. However, they can all be moved to the far left to optimize panel space. MBRK + - Each 98-CAP-40 capacitor module adds to the total system capacitance and increased energy storage. 4 Rockwell Automation Publication 98-IN008C-EN-P - April 07
5 Kinetix 5700 s Product Dimensions Refer to the Kinetix 5700 Servo Drives User Manual, publication 98-UM00, for system-wide drill hole specifications. Dimensions 9.5 (.6) 55 (.6) Dimensions are in mm (in.) 56.3 (.) DC BUS C B ULE A 98-CAP-xxxx-xx s 7.5 (.08) 7.5 (.08) 0.0 (0.39) D Cat. No. A B () C D 98-CAP (.8) 345 (3.58) 358 (4.09) 53 (0.0) 98-CAP-DCBUS-IO 3 (5.6) 76 (6.93) 89 (7.44) 48 (9.76) () The recommended mounting hardware is M5 (#0-3) steel bolts. Apply 4.0 N m (35.4 lb in) maximum torque to each fastener. Rockwell Automation Publication 98-IN008C-EN-P - April 07 5
6 Kinetix 5700 s Connector Data Lug spacers are needed only when wiring both external DC-bus and active shunt connections to the lug studs. Two types of lug covers are provided, one for systems with external DC-bus or active shunt wires attached and one without. Features and Indicators DC BUS CAP-40 (side view, lug cover removed) 0 ULE CAP-40 (front view) 7 4V 4V+ 8 4V 4V+ 98-CAP-40 (top views) Item Description Item Description Ground stud 7 DC-bus (DC) connector Module status (MS) connector 8 4V control input power (CP) connector 3 DC-bus status indicator 9 DC M8 stud (external DC-bus) 4 Module status indicator 0 5 Stud/lug cover with wires () DC+ M8 stud (external DC-bus), shown with wire lug M8 hex nut 6 Stud cover without wires Lug spacer () This example shows the lug cover oriented for wires exiting to the left (capacitor module is on the far left of the drive configuration). Rotate lug cover 80 when wires exit to the right (capacitor module is on the far right of the drive configuration). 6 Rockwell Automation Publication 98-IN008C-EN-P - April 07
7 Kinetix 5700 s Extension Module Features and Indicators CAP-DCBUS-IO Extension Module (side view, lug cover removed) 6 98-CAP-DCBUS-IO Extension Module (front view) CAP-DCBUS-IO Extension Module (top views) Item Description Item Description Ground lug 5 DC M8 stud (external DC-bus) Stud/lug cover with wires () 3 Stud cover without wires 7 M8 hex nut 4 DC-bus (DC) connector 8 Lug spacer () This example shows the lug cover oriented for wires exiting to the left (extension module is on the far left of drive configuration). Rotate lug cover 80 when wires exit to the right (extension module is on the far right of drive configuration). DC Bus (DC) Connector Pinout DC Pin Description Signal 6 DC+ M8 stud (external DC-bus), shown with flexible bus-bar (x) Bus link DC bus connections DC DC+ Rockwell Automation Publication 98-IN008C-EN-P - April 07 7
8 Kinetix 5700 s Control Input Power (CP) Connector Pinout CP Pin Description Signal 4V power supply, customer-supplied 4V+ 4V common 4V Module Status (MS) Connector Pinout MS Pin Description Signal Module status relay output + RELAY+ Module status relay output RELAY Wiring Requirements IMPORTANT The National Electrical Code and local electrical codes take precedence over the values and methods provided. Wiring Requirements Connector Description Module Status PELV/SELV 4V power (plug) DC-bus power DC-bus studs Pin MS- MS- CP- CP- Bus-bar Signal RELAY+ RELAY 4V+ 4V Recommended Wire Size mm (AWG) (8 6) (0 4) Strip Length mm (in.) 7.0 (0.8) 7.0 (0.8) N/A () N/A () Bus-bar DC N/A N/A DC+ Lugs 53.5 (/0) 00 A 85.0 (3/0) 00 A N/A () Torque Value N m (lb in) (.9.) (.9.) N/A () 8 (56) () DC bus connections are always made from drive-to-drive over the shared-bus connection system. These terminals do not receive discrete wires. () Strip length for the DC-bus studs depend on the customer-supplied lugs. ATTENTION: To avoid personal injury and/or equipment damage, observe the following: Make sure that the installation complies with specifications regarding wire types, conductor sizes, branch circuit protection, and disconnect devices. The National Electrical Code (NEC) and local codes outline provisions for safely installing electrical equipment. Use power connectors for connection purposes only. Do not use them to turn the unit on and off. Ground shielded power cables to prevent potentially high voltages on the shield. 8 Rockwell Automation Publication 98-IN008C-EN-P - April 07
9 Kinetix 5700 s Wire an External Active Shunt Active shunts wire to the DC-bus studs. The capacitor modules are equipped with spacers that slide onto the M8 studs. When the system configuration includes external DC-bus and active shunt connections, external DC-bus connections are made below the spacer and active shunt connections are made above the spacer. Active Shunt Connections Spacer Active Shunt Lug Connections (above spacer) DC-Bus Lug Connections (below spacer) 98-CAP-40 or 98-CAP-DCBUS-IO (98-CAP-40 module is shown) See Mount the Capacitor Modules on page for mounting information and example configurations. Active Shunts Compatible with Kinetix 5700 Drive Systems Rockwell Automation Encompass Partner Powerohm Resistors, Inc. Active Shunt Cat. No. Power Rating Current Rating kw Amps PKB005.5 N/A PKB00.0 N/A PKB N/A PWB PWB Rockwell Automation Publication 98-IN008C-EN-P - April 07 9
10 Kinetix 5700 s Connect Modules with Flexible Bus-bars When the 98-CAP-DCBUS-IO extension module is used, two flexible bus-bars make the external DC-bus lug connections to the 98-CAP-40 capacitor module. The DC-bus links must also be installed. Flexible Bus-bar Example Flexible bus-bars (external DC-bus connections) DC-bus Link Connections DC-bus Links 98-xxxx-ERS3 Inverters 4V 4V+ 9 SB+/NC SA SCA SA SB- SB SCB SB 8 6 4V 4V+ 98-CAP-DCBUS-IO Extension Module 98-CAP-40 ATTENTION: To avoid damage to components on 00 A systems, the DC-bus links and the flexible bus-bars must be installed. 0 Rockwell Automation Publication 98-IN008C-EN-P - April 07
11 Kinetix 5700 s Apply Stud/Lug Covers Covers ship with the capacitor modules and are used to protect you from the electrical hazard that is present on the DC-bus studs, lugs/wires, and flexible bus-bars that are attached to capacitor modules. Insert the appropriate cover over the external DC-bus connections. You can rotate the covers 80 to accommodate lugs, wires, or flexible bus-bars exiting from either the left or right. ATTENTION: To avoid personal injury, make sure that the appropriate cover is inserted over the DC-bus studs, lugs/wires, or flexible bus-bars when installing 98-CAP-40 and 98-CAP-DCBUS-IO capacitor modules. Covers with wires also require a hinged bottom plate to prevent access from below. Stud/Lug Cover With Wires Remove knockout for external DC-bus and active shunt connections. Remove knockouts for large wires and wire lugs. 98-CAP-40 or 98-CAP-DCBUS-IO Attach Bottom Plate Leave knockouts attached for small wires and wire lugs. Stud Cover With Wires ATTENTION: To avoid unintentional damage to the lug cover, we recommend cutting the knockout to remove it from the cover. Stud Cover With Flexible Bus-bars 98-CAP-40 or 98-CAP-DCBUS-IO Extension Module Remove knockouts when flexible bus-bars are used to connect the capacitor module and extension module. Rockwell Automation Publication 98-IN008C-EN-P - April 07
12 Ground Your to the Subpanel Ground Bulletin 98 drives and 98-CAP-xxxx-xx capacitor modules to a bonded cabinet ground-bus with a braided ground strap. Connecting the Braided Ground Strap 98-CAP-40 or 98-CAP-DCBUS-IO Extension Module (side view) Item Description 4 3 Ground screw (green).0 N m (7.5 lb in), max Braided ground strap (customer supplied) () 3 Ground grid or power distribution ground 4 Bonded cabinet ground-bus (customer supplied) () Make braided ground straps mm (0.5 in.) by 0.8 mm (0.03 in.). Keep straps as short as possible. Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Kinetix 5700 Servo Drives User Manual, publication 98-UM00 Kinetix 5700 Passive Shunt Modules Installation Instructions, publication 98-IN0 Industrial Automation Wiring and Grounding Guidelines, publication Product Certifications website, Description Provides information on installing, configuring, starting, and troubleshooting your Kinetix 5700 servo drive system. Provides information on installing and wiring Kinetix 5700 external shunt modules. Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details. You can view or download publications at Rockwell Automation maintains current product environmental information on its website at Allen-Bradley, Encompass, Kinetix, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat: İçerenköy, İstanbul, Tel: +90 (6) Publication 98-IN008C-EN-P - April 07 Supersedes Publication 98-IN008B-EN-P - July 05 *PN-48798* PN Copyright 07 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Kinetix 350 Single-axis EtherNet/IP Servo Drives
Installation Instructions Kinetix 350 Single-axis EtherNet/IP Servo Drives Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM, 2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM,
More informationKinetix 350 Single-axis EtherNet/IP Servo Drives
Installation Instructions Kinetix 350 Single-axis EtherNet/IP Servo Drives Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM, 2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM,
More informationKinetix 300 Single-axis Servo Drives
Installation Instructions Kinetix 300 Single-axis Servo Drives Catalog Numbers 2097-V31PR0, 2097-V31PR2, 2097-V32PR0, 2097-V32PR2, 2097-V32PR4, 2097-V33PR1, 2097-V33PR3, 2097-V33PR5, 2097-V33PR6, 2097-V34PR3,
More informationPump Panel Specifications
Technical Data Pump Panel Specifications Bulletin Numbers 13 and 133 Topic Page Specifications Electrical Ratings (Bulletins 13, 13X, 133, 133X) Mechanical Ratings (Bulletins 13, 13X, 133, 133X) 3 Construction
More informationIEC Starter Approximate Dimensions
Technical Data IEC Starter Approximate Dimensions Bulletin Numbers 103H/107H/140M, 103-C/107/C, 105, 109, 106, 112, 113, 190E/191E, 190S/191S, 103S/107S, 103T/107T Topic Page Enclosed Starters and Motor
More informationMP-Series Electric Cylinders Replacement Parts (Series B and C)
Installation Instructions Original Instructions MP-Series Electric Cylinders Replacement Parts (Series B and C) Catalog Numbers MPAR-NA3210C, MPAR-NA323C, MPAR-NA4012C, MPAR-NA405C, MPAR-NA6310C, MPAR-NA6320C
More informationBattery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions
Installation Instructions Original Instructions Battery Replacement Catalog Number 2711P-RY2032 Topic Page Summary of Changes 1 Important User Information 2 Precautions 3 About This Publication 2 Replace
More informationMP-Series (Series A and B) and TL-Series Electric Cylinders Replacement Parts
Installation Instructions Original Instructions MP-Series (Series A and B) and TL-Series Electric Cylinders Replacement Parts Catalog Numbers MPAR-NA3210C, MPAR-NA323C, MPAR-NA4012C, MPAR-NA405C, MPAR-NA6310C,
More informationSelection Guide. PowerFlex Digital DC Drive
Selection Guide PowerFlex Digital DC Drive PowerFlex Digital DC Drive The PowerFlex DC drive combines powerful performance with flexible control to produce a highly functional, cost effective drive and
More information1370 DC Loop Contactors and Lug Kits
Installation Instructions 1370 DC Loop Contactors and Lug Kits 1370 DC Contactors are electromagnetically held contactors specially designed to switch the armature current from a DC drive module to a shunt
More informationControl and Load Switch Specifications Bulletin Number 194E, 194L
Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13
More informationFeeder Circuit Breaker Units Secure Support Pan and Change Door Latch
Installation Instructions Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch Catalog Numbers 2193FZ Topic Page About This Publication 1 Required Tools 1 Important User Information 2
More informationInstallation Instructions
Installation Instructions Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Operating Mechanisms For use with Circuit Breakers 140G-G, 140MG-G, 140G-H, 140MG-H, 140G-I, 140MG-I, 140G-J, 140MG-J,
More informationSpare Allen-Bradle. Battery Replacement. Installation Instructions. About This Publication. Catalog Number 2711P-RY2032
Installation Instructions Battery Replacement Catalog Number 2711P-RY2032 Topic Page Important User Information 2 Precautions 3 Replace the Battery in PanelView Plus Terminals 3 Replace the Battery in
More informationInstallation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement
Installation Instructions PowerFlex 700 Drive - Frame 8 Components Replacement Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical
More informationApplying More Than One ArmorStart Motor Controller in a Single Branch Circuit on Industrial Machinery
Application Guide Applying More Than One ArmorStart Motor Controller in a Single Branch Circuit on Industrial Machinery Bulletin Numbers 280, 281, 284, 290, 291 Topic Introduction 2 Background 2 ArmorStart
More informationPreventive Maintenance Checklist of Industrial Control and Drive System Equipment
Service Bulletin Preventive Maintenance Checklist of Industrial Control and Drive System Equipment Use the following checklist as a guide in performing preventive maintenance. ATTENTION: Servicing energized
More information1494U Visible-Blade Disconnect Switch
Selection Guide 1494U Visible-Blade Disconnect Switch Bulletin Number 1494U What s Inside Contents Page 1494U Disconnect Switch Components 3 1494U Disconnect Switch Accessories 4 1494U Disconnect Switch
More informationKinetix VP Food Grade Servo Motors with mm Frame Size
Installation Instructions Original Instructions Kinetix VP Food Grade Servo s with 063 165 mm Frame Size Catalog Numbers VPF-A0632, VPF-A0633, VPF-A0752, VPF-A0753, VPF-A1001, VPF-A1002, VPF-A1003, VPF-A1153,
More informationKinetix 5700 Drive Systems
2 1 1 4 I/O MOD NET 2 1 D+ D- 1 5 1 UFB MF MOD NET 2 1 D+ D- MOD NET 1 I/O-A 6 1 I/O-B 6 5 1 5 1 UFB-A UFB-B MF-A D+ D- MF-B MODULE STATUS MOD DC BUS Design Guide Kinetix 57 Drive Systems Catalog Numbers
More information1321 Power Conditioning Products
Technical Data 1321 Power Conditioning Products Don t Ignore the Cost of Power Line Disturbance Topic Page Product Overview 2 1321-3R and 3RA Series Line Reactors 3 1321 Reflective Wave Reduction (RWR)
More informationBulletin 1609 Industrial Uninterruptible Power Supply (Cat 1609-D)
Installation Instructions Bulletin 1609 Industrial Uninterruptible Power Supply (Cat 1609-D) ATTENTION: Please read and save these instructions. This manual contains important instructions for the Bulletin
More informationExternal Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s 50L4060, 50LW4060, 50LR4060, 64L4060, 64LW4060, 64LR4060, LF150500W4, LF150643W4
External us Resistor Kit for LiquiFlo C Drives Drive M/N s 50L4060, 50LW4060, 50LR4060, 64L4060, 64LW4060, 64LR4060, LF150500W4, LF150643W4 Instruction Manual D2-3536!!!!! TTENTION: Only qualified electrical
More informationCENTERLINE 2500 Low Voltage Motor Control Centers and Power Distribution Gear Catalog Structure Breakdown
Technical ata CENTERLINE 2500 Low Voltage Motor Control Centers and Power istribution Gear Catalog Structure Breakdown Catalog Numbers 2500 Table of Contents Topic Page Additional Resources 2 Ordering
More informationVD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual
Instruction Bulletin VD0C06N908C July 1998 Raleigh, NC, USA ALTIVAR 66, ALTIVAR 58, ALTIVAR 18 Dynamic Braking Resistor Kit User s Manual DANGER HAZARDOUS VOLTAGE Read and understand this bulletin in its
More informationResistive Brake Module
Installation Instructions Resistive Brake Module (Catalog Numbers 2090-XB33-16, 2090-XB33-32, 2090-XB120-01, 2090-XB120-03, and 2090-XB120-06 This publication provides installation instructions for the
More informationAllen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500
Installation Instructions CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns Catalog Number 2500 Topic Page Important User Information 2 Location Planning 3 Environment 3 Removal
More informationE300 Electronic Overload Relay
Quick Start Original Instructions E300 Electronic Overload Relay Bulletins 193, 592 Important User Information Read this document and the documents listed in the additional resources section about installation,
More informationitrak System Technical Data Bulletin 2198T
Technical Data itrak System Bulletin 2198T Topic Page About the itrak System 3 Hardware Configuration 4 Design Considerations 11 itrak System Track 17 Motor Module 18 Movers 25 TriMax Bearing Rails 40
More informationInstallation Instructions
Installation Instructions This document provides information on how to install the 1-slot or 2-slot I/O chassis with integral power supply and adapter. It provides information on how to: install the chassis
More informationDrives in Common Bus Configurations with PowerFlex 755TM Bus Supplies
Application Techniques Original Instructions Drives in Common Bus Configurations with PowerFlex 755TM Bus Supplies Important User Information Read this document and the documents listed in the additional
More informationMP-Series Integrated Gear Motors
Installation Instructions MP-Series Integrated Gear Motors (Catalog Numbers: MPG-A004-031, MPG-A004-091, MPG-A010-031, MPG-A010-091, MPG-B010-031, MPG-B010-091, MPG-A025-031, MPG-A025-091, MPG-B025-031,
More informationKinetix 7000 High Power Servo Drives
Kinetix 2000 Slot-filler Module This section contains dimensions and catalog numbers for the 2093-PRF slot-filler module. IMPORTANT The Kinetix 2000 slot-filler module (catalog number 2093-PRF) is compatible
More informationSingle Cable Motion Solution Kinetix 5500 Servo Drive and VP Low Inertia Motor
Single Cable Motion Solution Kinetix 5500 Servo Drive and VP Low Inertia Motor 2 Kinetix 5500 Servo Drive and VPL motor The Kinetix 5500 and VP Low Inertia Motor are designed to connect and operate with
More informationMounting System Specifications
Technical Data Mounting ystem pecifications Bulletin Number 141A Topic Page Cat. No. Explanation 2 General pecifications 4 Approximate Dimensions 7 Additional Resources These documents contain additional
More informationRDD-Series Rotary Direct Drive Bearingless Motors
Installation Instructions RDD-Series Rotary Direct Drive Bearingless Motors Catalog Numbers RDB-B2151, RDB-B2152, RDB-B2153 Topic Page Important User Information 2 Catalog Number Explanation 3 Before You
More informationCON EDISON EQUIPMENT
CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200
More informationExternal Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s 120L4060, LF151200W4
External us Resistor Kit for LiquiFlo Drives Drive M/N s 120L4060, LF151200W4 Instruction Manual D2-3537!!!!! TTENTION: Only qualified electrical personnel familiar with the construction and operation
More informationOverhead Bus for Bulletin 2300 MCCs
Installation Instructions Overhead Bus for Bulletin 2300 MCCs For Use in Parallel Bus Supply Configurations Contents What This Kit Contains This document shows how to install overhead bus assemblies on
More information1329I Integrated Drive/Motor CE Filter Option Kit
Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the
More informationAllen-Bradley Kinetix 5700 Servo Drive
Allen-Bradley Kinetix 5700 Servo Drive Helping to Deliver an Innovative Motion Control System The Kinetix 5700 servo drive helps expand the value of integrated motion on EtherNet/IP to large, custom machine
More informationAllen-Bradley HP Inverting Fault Circuit Breaker Kit
Allen-Bradley 1397 400-600HP Inverting Fault Circuit Breaker Kit Cat. Nos. 1397-IFB600 What This Option Provides This option is intended to be applied to regenerative 1397 drives with high inertia loads.
More informationExternal Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx
External us Resistor Kit for LiquiFlo Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx Instruction Manual D2-3538!!!!! TTENTION: Only qualified electrical personnel familiar with the
More informationDisconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494
Technical ata isconnect Switch and ircuit reaker Mechanism Specifications ulletin Number 1494 Topic Page 1494U isconnect Switch Specifications 2 1494, 1494F, 1494G, 1494R, 1494V isconnect Switch Specifications
More informationDirect Communication Module
Installation Instructions Direct Communication Module (Catalog Number 1747-DCM) Inside...................................... page For More Information.............................. 3 Hazardous Location
More informationKinetix Rotary Motion Specifications
Technical Data Kinetix Rotary Motion Specifications Kinetix VP, MP-Series, Kinetix 6000M, TL-Series, HPK-Series, RDD-Series Topic Page Topic Page Kinetix VP Low Inertia Motors 2 Kinetix 6000M Integrated
More informationM T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed
More informationMatrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING
Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.
More informationPowerFlex 700 Drive - Frame 8 Components Replacement
Installation Instructions PowerFlex 700 Drive - Frame 8 Components Replacement Catalog Numbers 20B Important User Information Read this document and the documents listed in the additional resources section
More informationPowerFlex 7000 AC Drive with Direct-to-Drive Technology. Re-installing a Common Mode Choke Bulletin 7000 Installation Instructions
PowerFlex 7000 AC Drive with Direct-to-Drive Technology Re-installing a Common Mode Choke Bulletin 7000 Installation Instructions Important User Information Solid-state equipment has operational characteristics
More informationPRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V
PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable
More informationPowerFlex 700 User Manual Update
DANGER REMOTE SOURCE(S) OF POWER. DISCONNECT ALL SOURCES OF POWER BEFORE OPENING THE DOOR. ENERGY STORAGE CAPACITORS. VERIFY LOW VOLTAGE DISCHARGE BEFORE SERVICING. SEE INSTRUCTION MANUAL. Document Update
More informationSMC Dialog Plus Specifications
Technical Data MC Dialog Plus pecifications Bulletin Number 150 Topic Page Product Overview 2 tandards Compliance and Certifications 2 Modes of Operation 3 Features 5 Catalog Number Explanation 6 General
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-ASB Series B) 1 9 2 3 4, 5 6 7 8 Component Identification 1 Remote I/O Adapter module 2 Indicators 3 Communication reset pushbutton (PRL) 4 Access door to switches
More informationPowerFlex 6000 Medium Voltage AC Drives
PRELIMINARY INFORMATION PowerFlex 6000 Medium Voltage AC Drives Simple. More Reliable. Easy-to-use. User-friendly Control for Variable and Constant Torque Applications Cost-effective solutions for new
More informationDrive Technology \ Drive Automation \ System Integration \ Services. Data sheet. MOVIAXIS Multi-Axis Servo Inverter. Information regarding UL
Drive Technology \ Drive Automation \ System Integration \ Services Data sheet MOVIAXIS MultiAxis Servo Inverter Information regarding UL Edition 0/0 057 / EN SEWEURODRIVE Driving the world Contents Contents
More informationPowerFlex 700 Drive - Frame 9 Components Replacement
Installation Instructions PowerFlex 700 Drive - Frame 9 Components Replacement Catalog Numbers XXX XXX XXXX XXX XXX XXX Important User Information Solid-state equipment has operational characteristics
More informationMATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation
MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 080920 2008 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter is designed for harmonic mitigation
More informationPowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit
Installation Instructions PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static
More informationInverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC
Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 40-75 HP @ 230 VAC and 75-150 HP @ 460 VAC Model Numbers: 906FK1101 and 906FK1201 Instruction Manual D2-3330-2! ATTENTION:
More informationMATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation
MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 120628 REV. 007 2012 MTE Corporation Matrix Series D User s Manual 600VAC IMPORTANT USER INFORMATION NOTICE The MTE Corporation
More informationMATRIX FILTER USER MANUAL. SERIES D 400 Volts, 50HZ PART NO. INSTR 025 REL REV MTE Corporation
MATRIX FILTER SERIES D 400 Volts, 50HZ USER MANUAL PART NO. INSTR 025 REL. 110624 REV. 006 2011 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter is designed for harmonic
More informationInstallation Instructions. Y-Series Brushless Servo Motor
Installation Instructions Y-Series Brushless Servo Motor Catalog Number Y-1002-1, Y-1002-2, Y-1003-1, Y-1003-2, Y-2006-1, Y-2006-2, Y-2012-1, Y-2012-2, and Y-3023-2 These installation instructions describe
More informationInstallation Instructions. PowerFlex 700 Drive - Frame 7 Components Replacement
Installation Instructions PowerFlex 700 Drive - Frame 7 Components Replacement Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical
More informationThese documents contain additional information concerning related products from Rockwell Automation.
Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Title PowerFlex 0-Series Drive Installation Instructions PowerFlex 0-Series Programming
More informationM T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 1201 South 2nd Street Milwaukee, WI 53204 U.S.A. EU Declaration of Conformity Kinetix 5500/5700 Digital Servo Drives and Accessories
More informationRotary Disconnect Switches, Bulletin 194R
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Rotary Disconnect Switches Bulletin 194R NOTICE: The specification guidelines in this document are intended to aid in the specification
More informationKinetix Linear Motion Specifications
Technical Data Kinetix Linear Motion Specifications MP-Series, LDAT-Series, LDC-Series, LDL-Series Topic Page Summary of Changes 2 Servo Drive Compatibility 2 LDAT-Series Integrated Linear Thrusters 3
More informationDynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures
Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to 150 HP @ 230 VAC, 3 HP to 600 HP @ 460 VAC without NEA1 Enclosures odel Numbers 912FKxxxx and 913FKxxxx Instruction anual
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationCompact Circuit Protector (CCP)
Supersedes April 2014 UL Class CC, CF (CUBEFuse ), Midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-Pole Class CC, Midget, 10x38mm Description & Specifications....
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationOperating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Operating Instructions MOVIAXIS MultiAxis Servo Inverter Information regarding UL Edition 0/0 685 / EN SEWEURODRIVE Driving the world
More informationUser s Guide Includes Mounting, Installation, and Product Registration
User s Guide Includes Mounting, Installation, and Product Registration 250 T M About OutBack Power Systems OutBack Power Systems is a leader in advanced energy conversion technology. Our products include
More informationMATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation
MATRIX FILTER SERIES D 480 Volts, 60HZ USER MANUAL PART NO. INSTR 024 REL. 120628 REV. 012 2012 MTE Corporation Matrix Series D User s Manual 480VAC IMPORTANT USER INFORMATION NOTICE The MTE Corporation
More informationDC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data
DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data Table of Contents 1370 DC Loop Contactors....................................3 Catalog Number Explanation...............................3
More informationVertical Load and Holding Brake Management
Application Technique Vertical Load and Holding Brake Management Bulletin Numbers 2198, 2094, 2097, VPL, VPC, MPL, MPM Topic Page Summary of Changes 1 Important User Information 2 Vertical and Horizontal
More information1489-M Circuit Breakers
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More informationM T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 040709 2003 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter
More informationMP-Series Food Grade Motors
MP-Series Food Grade Motors MP-Series (Bulletin MPF) food-grade motors combine the characteristics of the MP-Series low-inertia servo motors with features specifically designed to meet the unique needs
More informationTrane Liqui-Flo Addendum. Instruction Manual D2-3415
Trane Liqui-Flo Addendum Instruction Manual D2-3415 The information in this manual is subject to change without notice. Throughout this manual, the following notes are used to alert you to safety considerations:!
More informationPRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES
PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES Rockwell Automation expands its new line of Allen-Bradley Bulletin 1494C Cable-Operated, -Mounted Switches that meet industrial
More informationSineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING
SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of
More informationFIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z
PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install fixed power factor correction equipment as specified herein and as shown on the contract drawings. This specification
More informationmygrid Installation Notes
mygrid Introduction mygrid kits provide an easy to install, compliant, Solar Hybrid (On-Grid) or Off-Grid battery system. These installation notes outline all the processes required to effectively install
More informationNo-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together Recognized by UL and cul STATES Type have
More informationPowerFlex DC Drive - Frame A Pulse Transformer Circuit Board
Installation Instructions PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the
More informationCapacitor-based DC Uninterruptible Power Supplies
Reference Manual Original Instructions Capacitor-based DC Uninterruptible Power Supplies Catalog Numbers 1606-XLSCAP24-6, -XLSCAP24-12 Important User Information Read this document and the documents listed
More informationKinetix Linear Motion Specifications MP-Series, TL-Series, LDAT-Series, LDC-Series, LDL-Series
Technical Data Kinetix Linear Motion Specifications MP-Series, TL-Series, LDAT-Series, LDC-Series, LDL-Series Topic Page LDAT-Series Integrated Linear Thrusters 2 MP-Series Integrated Linear Stages 37
More informationProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions
DEH 40026 Installation Instructions g ProTrip Conversion Kits For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION GE Conversion Kits are designed for upgrading existing
More informationSMC -50 Technology and Control Advances
White Paper SMC -50 Technology and Control Advances Sensorless Linear Acceleration and Energy Management Topic Page Introduction 2 Energy Effectiveness with Appropriate Starting Method 3 SMC-50 Starting
More informationCompact Circuit Protector
Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationdv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING
dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.
More informationSUPPLEMENT MANUAL IM250R03. AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)
SUPPLEMENT MANUAL IM250R03 AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167) TABLE OF CONTENTS SAFETY Use of Warnings and Notes...3 INSTALLATION
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationAllen-Bradley Motors. NRU Diode Bridge Assembly Replacement ( A DC) REPLACEMENT KIT INSTRUCTIONS. Contents. What This Kit Contains
REPLACEMENT KIT INSTRUCTIONS NRU Diode Bridge Assembly Replacement (180-350A DC) Contents In 180A DC and 350A DC NRUs, all 6 diodes (D1 - D6) and the both the positive and negative heatsinks (HS1 - HS2)
More informationGF-SERIES GLOBALFRAME CABINET SYSTEM
P R O D U C T D ATA S H E E T GF-SERIES GLOBALFRAME CABINET SYSTEM K E Y F E AT U R E S Cost-effective cabinet solution adaptable to server, network and mixed-use applications Available in two configurations
More information