Cam Switches, Manual Motor Controllers, Disconnects For Single phase Applications
|
|
- Adele Conley
- 6 years ago
- Views:
Transcription
1 7/ Moeller Electric Corporation Manual Motor Controllers, Disconnects For use as Padlockable, red handle with yellow collar, suitable as Emergency-Stop Circuit function diagram Front Plate No. ) ON OFF FS 98 Main (Number of power poles) N.O. Auxiliary N.O. N.C. Max. Rating 5-6 Hz, singlephase 5 V V 3 V Current Rating A Basic type for..., insert mounting Motor disconnect switches ¾ T--8/... EA/SVB-NA 8 ½ T3--8/... EA/SVB-NA ½ 65 T5B--8/... EA/SVB-NA 87 ¾ T--/... EA/SVB-NA 368 ½ T3--/... EA/SVB-NA ½ 65 T5B--/... EA/SVB-NA 85 3 ½ 3 3 P-5/... EA/SVB P-3/... EA/SVB ½ 6 P3-63/... EA/SVB P3-/... EA/SVB 73 Motor disconnect switches with load shedding auxiliary contact 3 ½ 3 3 P-5/... EA/SVB/HI P-3/... EA/SVB/HI ½ 6 P3-63/... EA/SVB/HI P3-/... EA/SVB/HI 9383 Notes: ) Surface mounting enclosures are IEC type, totally insulated, corrosion-resistant rated IP 65, NEMA rated 3R,. ) All handles supplied in the above combinations are padlockable in the OFF position. Switches with red handles and yellow collars (...SVB) are suitable as Emergency-Stop main disconnect switches per Machinery Directive Standard EN 6 -. In applications where the switch is not intended to fulfill the Emergency-Stop function, use black handle and collar (...SVB-SW). 3) All switches are UL ed and CSA certified as manual controllers, additionally evaluated as motor disconnects per the intent of NEC. All switches are in compliance with IEC/EN (switch-disconnectors) and are CE marked. For IEC ratings consult Moeller Electric. ) All front plates shown may be exchanged at the time of the order at no extra charge. The prerequisite is that switching angles, the number of positions and the location of position must be identical; a pages 7/5 and 53 for ordering details. English front plates supplied with the switches as shown in the catalog, can be exchanged for their French equivalent by adding the FS... number shown with suffix -F to the switch type (Example: T--8/EA/SVB-NA+FS98-F).
2 Moeller Electric Corporation 7/3 Manual Motor Controllers, Disconnects Emergency-Stop device without Emergency-Stop function Surface mounting ) Padlockable red handle with yellow collar suitable as Emergency-Stop Padlockable, red handle with yellow collar suitable as Emergency- Stop Padlockable, black handle and collar Surface mounting ) Padlockable black handle and collar Padlockable, black handle and collar I/SVB-NA I/SVB-SW-NA I/SVB-NA I/SVB-SW-NA I/SVB-NA I/SVB-SW-NA I/SVB-NA I/SVB-SW-NA I/SVB-NA I/SVB-SW-NA I/SVB-NA I/SVB-SW-NA I/SVB-NA V/SVB EA/SVB-SW 8365 I/SVB-SW-NA V/SVB-SW 5738 I/SVB-NA 5589 V/SVB EA/SVB-SW 53 I/SVB-SW-NA 5589 V/SVB-SW 558 I/SVB-NA V/SVB 88 EA/SVB-SW I/SVB-SW-NA V/SVB-SW 63 I5/SVB-NA 5593 V/SVB EA/SVB-SW 663 I5/SVB-SW-NA 559 V/SVB-SW 6976 I/SVB/HI-NA V/SVB/HI 9586 EA/SVB-SW/HI 79 I/SVB-SW/HI-NA V/SVB-SW/HI 9899 I/SVB/HI-NA 5589 V/SVB/HI 55 EA/SVB-SW/HI 77 I/SVB-SW/HI-NA V/SVB-SW/HI 758 I/SVB/HI-NA 559 V/SVB/HI 637 EA/SVB-SW/HI 6 I/SVB-SW/HI-NA 559 V/SVB-SW/HI 7 I5/SVB/HI-NA 5596 V/SVB/HI 39 EA/SVB-SW/HI 3756 I5/SVB-SW/HI-NA 5597 V/SVB-SW/HI 365
3 7/ Moeller Electric Corporation Manual Motor Controllers, Disconnects Circuit function diagram Front Plate No. 3) OFF ON FS 98 Main (Number of power poles) N.O. Auxiliary N.O. N.C. Max. rating 5-6 Hz, singlephase 5 V V 3 V Current rating A Basic type for..., insert mountng On-Off switches, with black handle and silver-colored front plate ¾ T--8/... E-NA 7 ½ T3--8/... E-NA ½ 65 T5B--8/... E-NA 87 ¾ T--/... E-NA 367 ½ T3--/... E-NA ½ 65 T5B--/... E-NA 85 3 ¾ T--/... E-NA 75 ½ 3 3 P-5/... E P-3/... E ½ 6 P3-63/... E P3-/... E 67 On-OFF switches, with auxiliary ¾ T--5679/... E ½ 3 3 P-5/... E/HI P-3/... E/HI ½ 6 P3-63/... E/HI P3-/... E/HI 6957 Fractional motor reversing switch, auxiliary winding 6 ¾ T-3-598/... E-NA 9869 ½ T /... E-NA 76 Notes ) Surface mounting enclosures are IEC type, totally insulated, corrosion-resistant to IP 65, NEMA rated 3R,. ) Above switches are identical to the selection on pages 7/ and 3, except that the associated handle is not padlockable. Exception: P3-.../ can be padlocked in the Off position. All above handles are black with light grey front plate. 3) All front plates shown may be exchanged at the time of the order at no extra charge. The prerequisite is that switching angles, the number of positions and the location of position must be identical; a pages 7/5 and 53 for ordering details. English front plates supplied with the switches as shown in the catalog, can be exchanged for their French equivalent by adding the FS... number shown with suffix -F to the switch type (Example: T--8/E-NA+FS98-F).
4 Moeller Electric Corporation Manual Motor Controllers, Disconnects 7/5 Center mounting.5 mm opening Surface mounting ) Enclosure with cover Front IP 3 with cover mounted handle and coupling drive -NA 9 -NA NA 369 -NA NA I5-NA 559 -NA 989 -NA 55 -NA 756 -NA 878 -NA NA 378 -NA 733 -NA 858 -NA NA I /HI 837 /HI 698 I/HI-NA 9886 I/HI-NA 9887 I/HI-NA 9888 I5/HI-NA 9889 /HI 537 /HI 6978 /HI 8593 /HI 985 /HI /HI 77 /HI /HI 933 -NA 987 -NA NA NA NA 767
5 7/6 Moeller Electric Corporation Manual Motor Controllers, Disconnects Circuit function diagram Front plate No. 3) FS 98 GE Main (Number of power poles) N.O. Auxiliary N.O. N.C. Max. rating 5-6 Hz, single-phase 5 V V 3 V Current rating A Basic type for..., insert mounting Emergency-Stop switches, with red handle and yellow front plate ¾ T--8/... E-RT-NA 9898 ½ T3--8/... E-RT-NA ½ 65 T5B--8/... E-RT-NA 99 ¾ T--/... E-RT-NA 99 ½ T3--/... E-RT-NA ½ 65 T5B--/... E-RT-NA ¾ T--/... E-RT-NA 99 ½ 3 3 P-5/... E-RT P-3/... E-RT ½ 6 P3-63/... E-RT P3-/... E-RT 789 Notes ) Surface mounting enclosures are IEC type, totally insulated, corrosion-resistant rated IP 65, NEMA rated 3R,. ) Above switches are identical to the selection on pages 7/ and 3, except that the associated handle assembly is red with yellow background, making them suitable for Emergency-Stop applications. Handles are not padlockable. For padlockable handles used in Emergency-Stop applications, a 7/8. 3) All front plates shown may be exchanged at the time of the order at no extra charge. The prerequisite is that switching angles, the number of positions and the location of position must be identical; a pages 7/5 and 53 for ordering details. English front plates supplied with the switches as shown in the catalog, can be exchanged for their French equivalent by adding the FS... number shown with suffix -F to the switch type (Example: T--8/E-RT-NA+FS98-F).
6 Moeller Electric Corporation Manual Motor Controllers, Disconnects 7/7 Surface mounting ) Enclosure with cover Front IP 3 I-RT-NA 995 -RT-NA 996 I-RT-NA 996 I-RT-NA 997 I-RT-NA 998 -RT-NA 997 I-RT-NA 999 I-RT-NA 99 I-RT-NA 99 -RT-NA 998 I-RT-NA RT 3 I-RT-NA RT 63 I-RT-NA RT 585 I5-RT-NA RT 8685
7 7/8 T Cam Switches Moeller Electric Corporation Circuit function diagram Front Plate No. 3) Main (Number of power poles) N.O. Max. rating 5-6 Hz, single-phase 5 V V 3 V Current rating A Basic type for..., insert mounting Change-over switches with OFF position FS 68 FS 68 Change-over switches with OFF position with spring-return from both directions to ¾ T--8/... E 7 ½ T3--8/... E ½ 65 T5B--8/... E 96 ¾ T--8/... E 3 ½ T3--8/... E ½ 65 T5B--8/... E 939 ¾ T--8/... E-NA 59 ½ T3--8/... E-NA 999 ¾ T--85/... E 36 ½ T3--85/... E 675 Change-over switches without OFF position ¾ T--8/... E 378 ½ T3--8/... E 388 ¾ T--8/... E 3887 ½ T3--8/... E ½ 65 T5B--8/... E 937 Notes: ) Surface mounting enclosures are IEC type, totally insulated, corrosion-resistant rated IP 65, NEMA rated 3R,. ) All handles suppled with above switches are black with light gray front plate. 3) All front plates shown may be exchanged at the time of the order at no extra charge. The prerequisite is that switching angles, the number of positions and the location of position must be identical; a pages 7/5 and 53 for ordering details. English front plates supplied with the switches as shown in the catalog, can be exchanged for their French equivalent by adding the FS... number shown with suffix -F to the switch type (Example: T--8/E-NA+FS77-F).
8 Moeller Electric Corporation 7/9 T Cam Switches Center mounting Surface mounting ) Enclosure with cover Front IP 3 with cover mounted handle and coupling drive NA 6 -NA NA NA 6 -NA
Control and Indication Cam Switches. Cam Switches Rotary switches T & Switch disconnectors P
Control and Indication Rotary switches T & Switch disconnectors P F switches P, P ON- switches - P, P 9 switches P ON- switches - P Service distribution board mounting Rear mounting Flush mounting Neutral
More informationProduct Specification Sheet #3LD2.1
Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping
More informationApprovals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking
MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationApprovals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking
MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationLoad and Motor Switches, Load-Break Switches Series 8549
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Pick-off terminal block Auxiliary
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationLoad and Motor Switches, Load-Break Switches Series 8544
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: alligator clip auxiliary
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1
MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationUL Enclosed Disconnect Switches (Fused and Non-Fused)
Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66
More informationSingle Phase Switches ➊
eller series prducts Sinle Pase Switces ➊. f Ples Standard Faceplate (fr ter ptins, nte faceplate cde and frame size f desired switc and turn t pae.) Cntact Sequence Rated fr Applicatins Built-in Auxiliary
More informationUL/CSA Non-fused Disconnect Switches
Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationBulletin 194R Next Generation Global Fused and Non-Fused Disconnects
Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationCat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationPKZ and PKE motor-protective circuit-breakers
PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload
More informationSERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:
SERIES D DISCONNECT SWITCHES 1 Amp 0 Amp 00 & 0 Volt Load Make/Load Break Positive Opening Compact Size Modular Construction Horse Power Rated Custom Versions Featuring: Auto Alignment Shaft Wide Handle
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581
Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear
More informationDISCONNECT SWITCHES (16 TO 630 amp)
I DISCONNECT SWITCHES (16 TO 630 amp) Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We carry a complete line of UL approved, CSA listed, Disconnect
More informationPlug and Socket Devices SolConeX 16 A Series 8570
Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning
More information2.1. NEMA Contactors and Starters
3A Overload C306DN3B Contents Contactors Non-Reversing and Reversing...... Starters Three-Phase Non-Reversing and Reversing, Full Voltage.................... Starters Single-Phase Non-Reversing, Full Voltage,
More informationEnclosed Rotary Switch Product Specification Sheets Table of Contents
Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX
More informationSafety Switches Series 8537
Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part
More informationFM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationCertifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE
Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect
More informationBig performance in a small package
Series usible & Non-fusible 100 400A Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or usible Which is Best or Your Application? Application Data Typical Control Switch
More informationT38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T38 1" T Form 7 Malleable Iron Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit
More informationBig performance in a small package
Series Fusible & Non-fusible Sprecher + Schuh s series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications
More informationBig performance in a small package
Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationPower consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3
SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage
More informationApprobationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking
Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description
More informationSingle-Phase Ventilated
Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationSystem pro M compact Miniature Circuit Br eakers Description Features
System pro M compact Miniature Circuit reakers S0 Series Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding
More informationINDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com
More informationGHG43 Series Control Stations
GHG43 Series Control Stations Nonmetallic or 316L Stainless Steel UL/cUL listed Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, (A) Ex de IIB + H2 T6 Cl. II, Div. 1, Groups E, F, G (cul) PTB ATEX
More informationLoad and Motor Switches, Load-Break Switches Series 8544
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Alligator clip Auxiliary
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated
More informationFM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. : Conduit Bodies Applications Serve as pulling fittings. Make bends in conduit system. Provide
More informationThree-Phase Ventilated
Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationJust the right switch for your application
Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality
More informationFM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections for branch runs. Permit access to conductors
More informationSuitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators
SafeLine Compact, heavy duty disconnect 6A 200A 30A 200A Fusible Disconnect SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings
More informationCompact enclosures AE
Compact enclosures AE Material: 1.4301 (AISI 304) Mounting plate: Sheet steel Cam lock: Die-cast zinc, nickel-plated Surface finish: Brushed, grain 40 Mounting plate: Zinc-plated Protection category: IP
More informationIntegral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation
C R US Conforms to EN418, EN292, ISO/IEC1850, EN0947-5-1 UL and C-UL listed ER019 Combination Rope and Push-Button Actuated Emergency Stop Switch Long rope spans of up to 75 m (24 ft.) for standard model
More informationPRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V
PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable
More informationHubbell Industrial Controls, Inc. Class 58 Drum Controller Catalog & Price List April 2016, Replaces Nov 2015
Hubbell Industrial Controls, Inc. Class 58 Drum Controller Catalog & Price List April 206, Replaces Nov 205 Class 58 Drum Controllers start, stop and change the speed and/or rotating direction of reversible
More informationSuitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators
SafeLine Compact, heavy duty disconnect 16A 00A 30A 00A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational
More informationMaterial, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T37 1 T FM7 CND BD Appleton/Oz Gedney Catalog Number T37 Manufacturer Appleton/Oz Gedney Description FM7 Unilets Type
More information3VF3 to 3VF8 Circuit-Breakers
3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating
More informationIntegral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation
C R US Conforms to EN418, EN292, ISO/IEC1850, EN0947-5-1 UL and C-UL listed ER019 Combination Rope and Push-Button Actuated Emergency Stop Switch Long rope spans of up to 75 m (24 ft.) for standard model
More informationIEC Contactors. IEC Contactors. YS Series. YS Series Contactors YS1N- F11 ****
YS Series Contactors Key features of the YS Series include: Compact size AC and C coil, reversing and non-reversing Weld-resistant silver alloy contacts No cadium used in contacts Highly reliable auxiliary
More informationBulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches
2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin
More informationSiemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage
SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution
More informationSelf-protected Combination Starters System PKZ 2-SP
Self-protected Combination Starters System PKZ 2-SP 03/035 PKZ 2/ZM/S-SP motor starters: a higher level of protection and versatility : The PKZ 2/ZM/S-SP is a self-protected starter, the first motor controller
More informationJCAM SWITCHES. Model Ratings / Product Numbering System...J2 Technical Data...J3
Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We offer complete line of Cam Switches with as many as 24 switch contacts. Each contact has two fixed
More informationBig performance in a small package
Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! Manual Switching Devices: Control, oad or Fusible Disconnect Switches
More informationPRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES
PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES Rockwell Automation expands its new line of Allen-Bradley Bulletin 1494C Cable-Operated, -Mounted Switches that meet industrial
More informationBig performance in a small package
11 Series 11 Fusible up to 800A & Non fusible up to 1200 Amps Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or Fusible Which is Best For Your Application? Application
More information4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.
4 qwer Pilot Operated General Service Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Wide range of pressure ratings, sizes, and resilient materials provide
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More informationEXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable
More informationReceptacles & Wall Boxes with Integral Circuit Protection
product description New Product Announcement Issue date: 25 January 2012 Receptacles & Wall Boxes with Integral Circuit Protection Meltric s receptacle/wall box combinations with integral circuit protection
More informationPowerPact Circuit Breakers for Control Panel Disconnects Class 0611
Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical
More informationDISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Application Explosionproof circuit breaker enclosures are
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable
More informationThermal Overload Relays
Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They
More informationUL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊
Series U/CSA Fused Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 200V 240V 460V 600V 125V 250V Catalog Number Price U Class J and CSA HRCI-J Fuses ➋ 30
More informationNEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Distribution Equipment NEC/CEC CLASS/ZONE RATED HAZARDOUS
More informationBulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism
Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth
More informationMercmaster LED Series Luminaires Enclosed and Gasketed Fixtures
Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationThe compact LO series of switches range from 16A to 63A, and NT series of disconnects from 63A to 250A.
Disconnect Switches Disconnect Switches are control devices used to turn power ON-OFF on most machines, control panels, HVAC equipment. Many models feature a lockout to prevent unauthorized use. These
More informationGKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch
Series Dual Entry Solenoid Key Operated Safety Interlock Switch FEATURES Solenoid power to lock or power to unlock Side or top key entry Separate switches for key position and solenoid status Available
More informationOperating Instructions
Operating Instructions Load and Motor Switch, Load-Break Switch > 8544/1 Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical
More informationAC Line / Load Reactors
AC Line / Load Reactors Table of Contents Delivery / Lead Time.PB03-1100 -2 Selection & Pricing PB03-1100 -4 Replacement Parts..PB03-1100-8 Product Modifications / Options..PB03-1100 -9 Product Specifications..PB03-1100
More informationFM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationMotor protection switches M16 20A Main switches S25 25A
Motor protection switches M16 20A Main switches S25 25A DISA Elektro AG Kägiswilerstrasse 33 CH-6060 Sarnen Tel. 041 666 70 50 Fax 041 666 70 49 info@disa.ch www.disa.ch DISA your partner for individual
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty
More informationDATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.
DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN
More informationDATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer
DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up
More informationMTE AC Line / Load Reactors Price book
Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 REACTOR SELECTION & PRICING...4 208-240 VOLT (3-PHASE)...4 400 VOLT (50 HZ) USE FOR 380-415 VOLTS...5 480 VOLT (3-PHASE) REACTOR...6
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationGeneral_technical_data Series
Indicator actuator 2 500 Hz: 5 g Pushbutton actuator Lens flat/level with front bezel: - Momentary max. 3 600/h - Maintain max. 1 800/h Lens flat/raised above front ring: - Momentary max. 3 600/h - Maintain
More informationEnclosed Full-Voltage Starters
GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for
More informationFeed-through terminal, 2.5 mm², Tension clamp connection, Wemid, dark beige, TS 35
General ordering data Order No. 1608570000 Part designation 2.5/4AN Version EAN 4008190077136 Qty. 100 pc(s). Feed-through terminal,, Tension clamp connection, Wemid, Product notes Product description
More informationCompact Rope-Activated Emergency Stop Switch. DIN mounting pattern for a globally recognized mounting configuration
C R US Conforms to EN418, EN292, EN0947-5-1, EN50041, BS504, ISO1850 UL and C-UL listed ER4020 Compact Rope-Activated Emergency Stop Switch Compact size allows this switch to be used on smaller machines
More informationSeries L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38
Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45
More informationICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices
ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers
More informationPrewired position switches FF series
2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable
More informationMax. Input Power (W) Inrush Current (A pk /µs)
Output Power (W) Output Voltage (V) Output Current (A) Tcase Max 150 60~210 0.70 80 C Wiring Diagram Input Current 1.4A@120VAC 0.6A@277VAC 0.67A@250VDC Max. Input Power (W) Inrush Current (A pk /µs) Max.
More informationEnclosed Full-Voltage Starters
GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal
More informationPowerLine OS Switch Fuses A, 690V
Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected
More informationPlugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581
Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked
More informationClass I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature
More information