Big performance in a small package

Size: px
Start display at page:

Download "Big performance in a small package"

Transcription

1 Series usible & Non-fusible A Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or usible Which is Best or Your Application? Application Data Typical Control Switch Typical oad Break Switch Typical usible Switch Sprecher + Schuh s series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications that require small panel space and superior short circuit protection. Big performance in a small package disconnects are rated to 400A and can be operated at up to 600V. They protect motors up to 250HP (@460V). The may be installed on circuits capable of delivering up to 100,000A of short circuit fault current; levels typically found in modern industrial facilities. This performance comes in a small package, leaving room for additional branch circuit components within the panel. Maximum protection for downstream equipment switches are engineered to provide excellent short-circuit protection for downstream equipment. These switches accept the latest small-dimension HRCI-J and HRCII-C fuses. This Type 2 protection limits let-through currents to levels specified for IEC equipment, and ensures that when the short circuit is cleared, the device will be operable. Meets the toughest safety standards The series is suitable for use in service entrance applications. urther insuring safety, line-side terminal shields are standard on all disconnects. use covers are available for all devices, preventing contact with live parts. Common parts reduce inventory Universal auxiliary contact blocks fit on all frame sizes, reducing inventory. In addition, all frame sizes use the same operating handles and shafts. On-board fuse carriers also eliminate the need for extra components while reducing panel space requirements. Comprehensive standards and approvals disconnect switches conform to U 98 standards and are U isted, CSA and are designed to meet IEC 947-3, and applicable NEMA requirements. To learn the basic differences between control, load and fusible disconnect switches and how to apply them, ask your Sprecher + Schuh representative for publication no: Tech-MSD 45

2 Series U/CSA used Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 200V 240V 460V 600V 125V 250V Catalog Number Price U Class J and CSA HRCI-J uses ➋ Dimension Code 100 ~ 7.5 ~ ~ 20 -NJ100P3 744 C1 200 ~ 10 ~ ~ 40 -NJ200P D1 400 ~ ~ ~ 50 -NJ400P CSA HRCII-C uses 100 ~ ~ ~ -NH100P3 744 D1 200 ~ ~ ~ -NH200P E1 400 ~ ~ ~ -NH400P Items in Gray are Special Order U/CSA Non-used ➌ Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 200V 240V 460V 600V 125V 250V Catalog Number Price Dimension Code 100 ~ 7.5 ~ ~ 20 -NN100P3 744 C1 200 ~ 10 ~ ~ 40 -NN200P D1 400 ~ ~ ~ 50 -NN400P Note: usible and Non-fusible with dimension codes D, E & require lugs. Sprecher + Schuh lugs available on page 48. Ordering Instructions Specify Switch catalog number (this page) Specify desired switch handle catalog number (page 47) Specify desired operating shaft catalog number (page 47) Specify desired accessories (page 48) ➊ Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower rating. ➋ Only U listed Class J and CSA Certified HRCI-J fuses are suitable for use with these disconnect switches. ➌ Non-fused disconnect switches must use separately installed U isted Class J, CC or T fuses or CSA Certified HRCI-J fuses. 46

3 Series Switch Handle Assemblies Switch Handle Assembly ➊ Description Color Degree of Protection Catalog Number Price 103 X 103mm Pistol Grip Handle with defeater Pistol Grip Handle - or 100A, 200A and 400A switches ➌ - With Defeater - ockable: 3 locks ➋ Black Red/Yellow Type 1 IP42 -HM1 68 Type 3R, 3, 12, 4, 4X IP66 -HM4 104 Type 1 IP42 -HM1E 68 Type 3R, 3, 12, 4, 4X IP66 -HM4E X 103mm Pistol Grip Handle without defeater Pistol Grip Handle - or 100A, 200A and 400A switches ➌ - Without Defeater - ockable: 3 locks ➋ Black Red/Yellow Type 1 IP42 -HM1-N2 68 Type 3R, 3, 12, 4, 4X IP66 -HM4-N2 104 Type 1 IP42 -HM1E-N2 68 Type 3R, 3, 12, 4, 4X IP66 -HM4E-N2 104 Metal Operating Shafts Shaft (typical) Switch Dimension Code or use with handle type Operating Shaft ength (mm) Catalog Number Price C1, D1 Pistol Grip (-100/200A) 200 -R R E1, 1 Pistol Grip (-NH200/400A) 278 -R R ➊ Mounting screws included with Switch Handle Assembly. ➋ ockable in O position (and ON position with special modification). ➌ Can be used on 30 and 60A switches. Select -R1M or -R2M shaft. 47

4 Series Accessories Accessory Description Catalog Number Price Auxiliary Contact Blocks - One pole (NO) One pole (NC) Two pole (1 NO/1 NC) Two pole (NO) Two pole (NC) -GA10 -GA01 -GA11 -GA20 -GA02 ➊ Auxiliary Contact Support Kit - Required when mounting more than two Auxiliary Contact Blocks per switch. -A Switch Handle Instruction abel - or use with all Switch Handle Assemblies (10 per package - priced per package) use Covers ➋ - Dim. Code C1 D1 E1 1 Quantity Req d CC1 -CD1 -CE1 -C1 ➌ Replacement Terminal Shield ➌ - All come standard with one Terminal Shield. or use on either line or load side of the disconnect switch. Dim. Code C1 D1 E1 1 -NC3 -NC4 -NC5 -NC6 ➌ Terminal ugs - 3 per package Dimension Code Wire Size D1 10mm 2 50mm 2 (-NH100P3 only) #8 1/0 AWG D1 16mm 2 120mm 2 #6 250MCM AWG E1, 1 25mm 2 240mm 2 #4 500MCM AWG 1 Two 50mm 2 150mm 2 Two 1/0 350MCM AWG -E1-1 -G1 -H ➍ A maximum of four contact blocks can be installed on each disconnect switch. When more than two contact blocks are used, the Auxiliary Contact Support Kit (-A1) must be installed. ➋ Also used for covering the shorting bars on Non-fused switches. ➌ are supplied with line side lug (terminal) shields only. do not include dead-front or fuse covers. oad side terminal and fuse covers must be ordered separately as required. 48

5 Series Enclosed Motor s (U and CSA Approved Enclosures) Type 3/4/12 Watertight, Dusttight Sheetmetal Enclosure - IP66 Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure - IP66 Type 4/4X Watertight, Corrosion-Resistant Non-metallic Enclosure - IP66 Amp/Horsepower Rating U/ CSA Amps 1Ø (60 Hz) Horsepower 3Ø (60 Hz) 120V 240V 200V 240V 460V 600V Catalog Number Price Catalog Number Price Catalog Number Price NOTE: All Enclosed s come standard with a black handle with ON/O marking. or a yellow and red handle, add suffix E to the end of the catalog number. Example: change -N100P3 to -N100P3E. Dimension Code Non-used 100 ~ 7.5 ~ N100P C1 -CN100P C1 -KN100P C1 200 ~ 10 ~ N200P D1 -CN200P D1 -KN200P D1 400 ~ ~ N400P CN400P KN400P Class J used 100 ~ 7.5 ~ J100P C1 -CJ100P C1 -KJ100P C1 200 ~ 10 ~ J200P D1 -CJ200P D1 -KJ200P D1 400 ~ ~ J400P CJ400P KJ400P Dimension Code Dimension Code 49

6 Technical Information Series used for CSA HRCI-J and U Class uses ➊ Electrical Ratings NJ100P3 NJ200P3 NJ400P3 Standards and Approvals (see page 32) CSA use Type/U use Type HRCI-J/ HRCI-J/ HRCI-J/ Class J Class J Class J Maximum use Cartridge Size [A] Maximum Voltage AC [V] DC [V] Ampere Rating [A] Max. Short Circuit Prospective ault Current [ka] use Operating Characteristics Time Delay Non-time Delay Time Delay Non-time Delay Time Delay Non-time Delay Maximum HP 200V, 60Hz [HP] ~ ~ AC 240V, 60Hz [HP] V, 60Hz [HP] V, 60Hz [HP] AC 120V, 60Hz [HP] ~ ~ ~ ~ ~ ~ 240V, 60Hz [HP] ~ ~ DC 125V DC [HP] ~ ~ ~ ~ ~ ~ 250V DC [HP] Mechanical Ratings Degree of Protection (per IEC 947) Switch only IP00 IP00 IP00 Switch with Terminal Shields and use Cover(s) IP20 IP20 IP20 Mechanical Endurance ➋ [operations] 10,000 8,000 8,000 Handle Mechanism Operating Torque (max.) [Nm] [b.-in.] Terminal Capacity ➌ Power terminals [mm 2 ] Two [AWG] #14 #2 #6 250MCM Two 1/0 350MCM Auxiliary contact terminals [mm 2 ] [AWG] #14 #12 #14 #12 #14 #12 Maximum number of auxiliary contact blocks Approximate Weight [kg.] [lbs.] Minimum Enclosure Size Height [mm] [in.] Width [mm] [in.] 11 27/ / /64 Depth [mm] [in.] 6 3/ /16 ➊ Only CSA Certified HRCI-J and U isted Class J fuses are suitable for use with these disconnect switches. ➋ Based on Rockwell Automation tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 947-3, U 1087 and U98. ➌ See Power Wire Installation on page 58 for power terminal torque ratings. 50

7 Technical Information Series used for CSA HRCII-C uses Electrical Ratings - NH100P3 - NH200P3 - NH400P3 Standards and Approvals (see page 32) CSA use Type HRCII-C HRCII-C HRCII-C Maximum use Cartridge Size [A] Maximum Voltage - AC [V] Ampere Rating [A] Max. Short Circuit Prospective ault Current [ka] Maximum HP 200V, 60Hz [HP] AC 230V, 60Hz [HP] V, 60Hz [HP] V, 60Hz [HP] AC 115V, 60Hz [HP] 230V, 60Hz [HP] Mechanical Ratings Degree of Protection (per IEC 947) Switch only IP00 IP00 IP00 Switch with Terminal Shields and use Cover(s) IP20 IP20 IP20 Mechanical Endurance ➊ [operations] 10,000 8,000 8,000 Handle Mechanism [Nm] Operating Torque (max.) [b.-in.] Terminal Capacity ➋ Power terminals [mm 2 ] Two [AWG] #8 #1/0 #4 500MCM Two 1/0 350MCM Auxiliary contact terminals [mm 2 ] [AWG] #14 #12 #14 #12 #14 #12 Max. number of auxiliary contact blocks Approximate Weight [kg.] [lbs.] Minimum Enclosure Size Height [mm] [in.] 15 1/ Width [mm] [in.] 13 17/ / /64 Depth [mm] [in.] /16 9 9/16 ➊ Based on Sprecher+Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4 and IEC ➋ See Power Wire Installation on page 58 for power terminal torque ratings. 51

8 Technical Information Series Non-used for CSA and U Class Applications ➊ - NN100P3 - NN200P3 - NN400P3 Electrical Ratings Standards and Approvals (see page 32) Maximum use Cartridge Size [A] 100 ➋ 200 ➋ 400 ➋ Maximum Voltage AC [V] DC [V] Ampere Rating [A] Max. Short Circuit Prospective ault Current [ka] use Operating Characteristics Non-time Non-time Non-time Time Delay Time Delay Time Delay Maximum HP 200V, 60Hz [HP] AC 230V, 60Hz [HP] V, 60Hz [HP] V, 60Hz [HP] AC 115V, 60Hz [HP] V, 60Hz [HP] DC 125V DC [HP] 250V DC [HP] Mechanical Ratings Degree of Protection (per IEC 947) Switch only IP00 IP00 IP00 Switch with Terminal Shields and use Cover(s) IP20 IP20 IP20 Mechanical Endurance ➌ [operations] 10,000 8,000 8,000 Handle Mechanism Operating Torque (max.) [Nm] [b.-in.] Terminal Capacity ➎ Power terminals [mm 2 ] Two [AWG] #14 #2 #6 250MCM Two 1/0 350MCM Auxiliary contact terminals [mm 2 ] [AWG] #14 #12 #14 #12 #14 #12 Max. number of auxiliary contact blocks Approximate Weight [kg.] [lbs.] Minimum Enclosure Size Height [mm] [in.] Width [mm] [in.] 11 27/ / /64 Depth [mm] [in.] 6 3/ /16 ➊ Non-fused disconnects must use separately installed CSA Certified HRCI-J, HRCI-T or HRCI-MISC (also U isted as Class CC) fuses; or U isted Class J, CC or T fuses. ➋ When using CSA HRCI-J, HRCI-MISC (also U isted as Class CC) or HRCI-T fuses, and U Class J, CC or T fuses. ➌ Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 947-3, U 1087 and U98. ➍ ine and load terminal shields supplied as standard. ➎ See Power Wire Installation on page 58 for power terminal torque ratings. 52

9 Technical Information Series Environmental Data or All used and Non-used Environmental Ratings All used and Non-used Ambient Temperature Open [ C ()] ( ) Enclosed [ C ()] ( ) Storage [ C ()] ( ) Altitude (per IEC 947-1) [m] 2,000 Relative Humidity (per IEC 947-1) 90% at +20 C (+68 ) 50% at +40 C (+104 ) Auxiliary Contact Ratings All Auxiliary Contacts AC-11 Rating DC-11 Rating Volts U e Amps I e Volts U e Amps I e Thermal Current EEMAC/NEMA A600, P300 [A] 10 Insulation Voltage - IEC U i [V] 660 Approvals: U isted ile Nos. E E E E E CSA Certified ile No. R CE Marked Per IEC Meets IEC, VDE and BS standard requirements OVAG Certified ASTA Certified Catalog Number U98 (Miscellaneous Switch) U 1087 (Molded Case) CSA CE NEMA-type NJ-100, 200, 400 NH-100, 200, 400 NN-100, 200, 400 Yes No Yes No Conformity to Standards: IEC 947-3/EN ow voltage switchgear and control gear part 3:, disconnectors, switchdisconnectors and fuse-combination units. CE BS EN VDE 0660 CSA 22.2 No. 4 NEMA KS-1 U 1087 U 98 53

10 Application Methods Series 11 & Applications Within the United States and Canada General The requirements for disconnect switches used in motor branch circuits rated 600V and less are defined in Article 430, Part H of the U.S. National Electrical Code (NEC), NPA70. Canadian Electrical Code (CEC) requirements are very similar in the area of motor branch circuit disconnect requirements. or simplicity, we will treat the NEC and CEC requirements as being the same and reference specific sections of the US National Electrical Code. The requirements for properly sizing a disconnect switch are dependent on the type of application. The NEC refers to two types of applications: single motor and combination loads. A combination load consists of an application where two or more motors are used together or where one or more motors are used in combination with other loads, such as resistance heaters. Single Motor Applications Section Paragraph (a) states that the disconnect switch must have an ampere rating of at least 115% of the full load current rating of the motor. Example 1: for a motor with a full-load current of 22A, the disconnect switch must be rated at least 25.3A (22 x 1.15). If the disconnecting means under evaluation is rated in horsepower, the selection of the disconnect switch is even more straightforward; a disconnect switch must have a horsepower rating equal to, or greater than the horsepower rating of the motor at the applicable voltage. Example 2: or a motor with a 10HP rating at 460V AC, the disconnect switch must be rated at least 10HP at 460V AC. If the disconnect switch is rated in horsepower, and U isted, U Component Recognized, or CSA Certified, it will meet the requirements for the 115% full-load current rating stipulated by the NEC. Combination oad Applications Section Paragraph (c) addresses the rating of the disconnecting means for combination loads. This paragraph essentially requires that the loads that may be simultaneously on a single disconnecting means be combined to provide equivalent full-load and locked-rotor currents for what is then to be considered as a single motor for the purpose of selecting the appropriate disconnecting means. This means that it is necessary to identify the particular combination of connected loads which can be operating simultaneously and will result in the maximum full-load and locked-rotor current sums. The individual full-load current values are to be selected from Tables , , or and the locked-rotor values are to be from Table The equivalent single motor full-load current is the sum of the simultaneously operating motor full-load currents and the rating in amperes of the other loads operating at the same time. The equivalent locked-rotor current is the sum of the simultaneously started motors locked-rotor currents and the full-load currents of the remaining operating motor and non-motor loads. The disconnecting means shall have a current rating equal to or greater then 115% of the equivalent single motor full-load current and have a horsepower rating equal to or greater than the horsepower rating determined from the equivalent locked-rotor summation. Consider the following 460V application: oad HP ull-oad Current A Motor (simultaneous) Motor (not included) ➊ Motor (simultaneous) Motor (simultaneous) Other 7.0 (simultaneous) Total Equivalent 62.6 (simultaneous) ➊ Motor 2 is not included in the total since it cannot operate simultaneously with the other motor, therefore, the disconnect switch must be rated at least 72A (1.15 x 62.6). Consider now the locked-rotor current analysis for the same application: oad HP ocked Rotor Current A Motor 1 5 (7.6 A) 45.6 (simultaneous) Motor (not included) ➊ Motor (simultaneous) ➋ Motor (simultaneous) ➋ Other 7.0 (simultaneous) Total Equivalent (simultaneous) ➊ Note again that Motor 2 cannot operate simultaneously with the other loads. ➋ The largest equivalent locked-rotor current occurs when motors 3 and 4 start together while the other loads marked simultaneous are already operating. Since Motor 1 is not starting with Motors 3 and 4, its full-load current will be added to the total instead of its locked-rotor current. Table , which provides the correlation between locked-rotor currents and HP ratings, shows that a 40 HP rating is the equivalent for locked-rotor amperes. Therefore, the disconnect selected for this application must have a current rating of at least 72A and a HP rating of at least 40 HP. In this case, an disconnect switch rated for 100A and 60 HP at 460V would be an appropriate choice. What can be seen from this analysis is that, depending upon the number of motors that can start simultaneously, the actual size of the required disconnect is sometimes determined by the equivalent full load current (72A) and other times by the equivalent horsepower determined from the locked-rotor analysis (40 HP). 54

11 Technical Information IP Ratings Definitions IP Ratings Definitions IP Ratings Definitions The first IP number (left side of chart) is protection against solid objects. The second IP number (across top) is protection against liquids. The chart itself shows degrees of protection according to IEC 529. No protection vertically falling drops of water (condensation) Protected against dripping water with enclosure up to 15 from vertical Protected against sprayed water up to 60 from vertical sprayed water from all directions (limited ingress permitted) low pressure water jets from all directions (limited ingress permitted) strong jets of water from all directions immersion up to one meter long periods of immersion under pressure IP 0 IP 1 IP 2 IP 3 IP 4 IP 5 IP 6 IP 7 IP 8 1 meter IP0 IP00 No protection IP1 solid objects up to 50mm (accidental touch by hands) IP2 solid objects up to 12mm (fingers, knuckles) IP3 IP10 IP11 IP12 IP20 IP21 IP22 IP23 solid objects up to 2.5mm (tools, wires) IP4 IP30 IP31 IP32 IP33 IP34 IP40 IP41 IP42 IP43 IP44 solid objects up to 1mm (wires) IP5 IP50 IP53 IP54 IP55 IP56 dust (limited engress permitted) IP6 IP60 IP65 IP66 IP67 Totally protected against dust 55

12 Technical Information Ratings Definitions NEMA / U Type Definitions NEMA / U Type Indoor Use Outdoor Use Indoor or Outdoor Use or a degree of protection against: R 3 4 4X 6P 6 Incidental contact with enclosed equipment alling dirt Rust Circulating dust, lint, fibers and flyings Windblown dust alling liquids and light splashing Rain (limited water allowed inside) Rain (no water allowed inside) Snow and sleet Hosedown and splashing water Occasional prolonged submersion Oil or coolant spraying or splashing Corrosive agents Occasional temporary submersion 56

13 Dimensions Series Switch (100, 200 & 400A) Switch Approximate Dimensions Dimension Reference H W D A B D C1 D1 E (5 53/64) 184 (7 1/4) 220 (8 21/32) 250 (9 27/32) 194 (7 41/64) 236 (9 19/64) 278 (10 15/16) 308 (12 1/8) 130 (5 7/64) 148 (5 53/64) 180 (7 3/32) 213 (8 25/64) 106 (4 11/64) 106 (4 11/64) 150 (5 29/32) 150 (5 29/32) 170 (6 11/16) 212 (8 11/32) 252 (9 59/64) 282 (11 7/64) -HM Pistol Grip Switch Handle Assembly 4-M6 (4 1/4) 4-M6 (4 1/4) 4-M8 (4 5/16) 4-M8 (4 5/16) mm (1/16-3/16) O ON O (4-5/64) (4-5/64) ON (7-35/64) Cover Thickness 58 (2-9/32) mm (in.) ø 65 (ø 2-9/16) 37.5 (1-15/32) 75 (2-61/64) 37.5 (1-15/32) 75 (2-61/64) 26 (1-1/32) (6-7/32) 140 (5-33/64) 26.5 (1-3/64) (4) - ø 5.5 ( (4) - ø 7/32) ront of Cover (4-3/16) (4-3/16) (4-1/16) 57

14 Dimensions Series Power Wire Installation -NH100P3 -NH200P3 -NJ200P3 -NN200P3 -NA400P3 -NH400P3 -NJ400P3 -NN400P3 D -NJ100P3 -NN100P3 C -NH100P3 -NH200P3 -NJ200P3 -NN200P3 -NA400P3 -NH400P3 -NJ400P3 -NN400P3 C Dimension B C D A Reference mm 2 #AWG N m lb-in N m lb-in C ~ ~ D / E / E1 -G #4-500MCM H1 (2) (2) 1/0-350MCM O ON A B use Installation -NH100P3 -NJ100P3 -NJ200P3 -NA400P3 A -NH200P3 -NJ400P3 -NH400P3 A Catalog Number A N m lb-in -NJ100P NJ200P NH100P NA400P NH200P NH400P NJ400P

15 Dimensions Series Type 3/4/12 - Watertight, Dusttight Sheet Metal Enclosure (100A) ON O D Amps Type Dim. Ref. A B C D E G H 100 used & Non-fused C1 406 (16.00) 406 (16.00) 224 (8.80) 282 (11.10) 368 (14.5) 368 (14.5) 178 (7) 315 (12-25/64) Type 3/4/12 - Watertight, Dusttight Sheet Metal Enclosure (200 & 400A) Amps Type Dim. Ref. A B C D E G H used & Non-used used & Non-used D (16) 610 (24) 610 (24) 762 (30) 224 (8-51/64) 326 (12-51/64) 282 (11-5/64) 384 (15-5/64) 688 (27-5/64) 840 (33-5/64) 650 (25-9/16) 802 (31-9/16) 368 (13-31/64) 572 (22-1/2) 572 (22-1/2) 724 (28-1/2) 59

16 Dimensions Series Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure (100A) ON O D Amps Type Dim. Ref. A B C D E G H 100 used & Non-fused C1 406 (16.00) 406 (16.00) 224 (8.80) 282 (11.10) 368 (14.5) 368 (14.5) 178 (7) 315 (12-25/64) Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure (200 & 400A) Amps Type Dim. Ref. A B C D E G H used & Non-used used & Non-used D (16) 610 (24) 610 (24) 762 (30) 224 (8-51/64) 326 (12-51/64) 282 (11-5/64) 384 (15-5/64) 688 (27-5/64) 840 (33-5/64) 650 (25-19/32) 802 (31-15/32) 368 (14-1/2) 572 (22-1/2) 572 (22-1/2) 724 (28-1/2) 60

17 Dimensions Series Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (100A) K 5 (3/16) A H D C B J 32 (1-9/32) G (4)- 8 X 13 SOT MTG. HOES (11/32) (17/32) Amps Type Dim. Ref. A B C D G H J K 100 used & Non-used C1 380 (14-31/32) 420 (16-1/4) 215 (8-31/64) 273 (10-49/64) 430 (16-61/64) 305 (12) 370 (14-9/16) 457 (18) 5 (13/64) Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (200A) K 11.5 (29/64) A D C B J G (4)- 10 DIA. MTG. HOES (13/32) Amps Type Dim. Ref. A B C D G J K 200 used & Non-used D1 513 (20-13/64) 625 (24-5/8) 292 (11-31/64) 350 (13-25/32) 648 (25-1/2) 457 (18) 686 (27) 11.5 (29/64) 61

18 Dimensions Series Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (400A) K 10.5 (27/64) A D C B J 57mm (2-1/4") G (4)- 10 DIA. MTG. HOES (13/32") Amps Type Dim. Ref. A B C D G J K 400 used & Non-used (24 1/8) 775 (30 33/64) 343 (13 31/64) 401 (15 23/32) 796 (31 31/32) 555 (21 7/8) 834 (32 27/32) 10.5 (13/32) 62

Big performance in a small package

Big performance in a small package Series Fusible & Non-fusible Sprecher + Schuh s series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications

More information

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊ Series U/CSA Fused Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 200V 240V 460V 600V 125V 250V Catalog Number Price U Class J and CSA HRCI-J Fuses ➋ 30

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! Manual Switching Devices: Control, oad or Fusible Disconnect Switches

More information

Big performance in a small package

Big performance in a small package 11 Series 11 Fusible up to 800A & Non fusible up to 1200 Amps Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or Fusible Which is Best For Your Application? Application

More information

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Bulletin 194R TABLE OF CONTENTS Bulletin 194R 20 A 400 A Sizes Open or Enclosed Switches d Switch Versions: BS88 DIN CSA HRCII-C CSA HRCI-J UL Class J UL Class CC Non-d Switches Operating Handle Ingress

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38 Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

LDisconnect Switches. Disconnect Switches

LDisconnect Switches. Disconnect Switches Disconnect Switches Disconnect Switches Series 7 - Motor Disconnect Switches up to 100A...2 Handles & Accessories...10 Series 7 Enclosed Disconnect Switches...14 Technical Information...20 Dimensions...22

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

194R J S TY N1

194R J S TY N1 Bulletin R IE Fused and Non-Fused Disconnects, & A Product Selection omplete UL/SA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IE Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - SA HRII- - SA HRI-MIS - UL lass

More information

Technical data OT16E3 OT160E3 UL & CSA

Technical data OT16E3 OT160E3 UL & CSA Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58

More information

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 3150A 30A 3000A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

SECTION. Watertight & Dust-Tight Plugs & Connectors

SECTION. Watertight & Dust-Tight Plugs & Connectors SECTION Watertight & ust-tight Wetguard Product Line Section Contents LIFETIME Wetguard Plugs, Connectors & Straight Blade 2-Pole 3-Wire 2-Pole 3-Wire 3-Pole 4-Wire 3-Pole 3-Wire Non- 4-Pole 4-Wire Non-

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

ENCLOSED DISCONNECT SWITCHES

ENCLOSED DISCONNECT SWITCHES Ferraz Shawmut Enclosed isconnect es are designed to meet customer s requirements for compact and durable individual disconnecting means. Both fusible and non-fusible versions are available in a variety

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity Cam-Lok connectors are the industry standard Cam-Lok

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8 Enclosed Control. Welcome............................................... Eaton Corporation........................................ Eaton Support and Service Center Capabilities.................. Technical

More information

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753 Depth x  Width x 2.375 Height 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

SECTION SECTION. EATON 2014 Arrow Hart Buyers Guide

SECTION SECTION.     EATON 2014 Arrow Hart Buyers Guide F SECTION SECTION 1 EATON 2014 Arrow Hart Buyers Guide FSECTION Cam-lok Single Pole Connectivity Table of contents Product selector guide F-3 NEMA rating system F-4 F-series F-5 E1010 F-6 E1012 F-7 F-series

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

FUSIBLE DISCONNECT SWITCHES

FUSIBLE DISCONNECT SWITCHES FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side

More information

Section Contents. Disconnect Switches

Section Contents. Disconnect Switches Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers Move to modern enclosed disconnect switch technology Enclosed disconnect switches eot Manual motor controllers The next generation of enclosed disconnect switches... Cutting edge design and technology

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers Product Guide QR Circuit Breaker usa.siemens.com/circuitbreakers Advantages to reduce your cost and improve installation flexibility. 250A, 240V AC breakers up to 100kAIC. Updated design includes pushtotrip

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems.

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

L11 Fused and Non-Fused Disconnect Switches (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

L11 Fused and Non-Fused Disconnect Switches (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. Series 11 used and Non-used isconnect Switches (30 & 60A) W A E H imension Approximate imensions in mm (in) Reference H W A ➊ E ➊ A1 108 (4-1/4) 120 (4-3/4) 101 (4) 90 (3-9/16) 105 (4-1/8) 85 (3-11/32)

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches es Series es... 2 Assemblies... 11 s... 15 Accessories... 25 Technical Information... 26 Dimensions... 31 Series R-Line es... 34 s... 39 Accessories... 40 Technical Information... 41 Dimensions... 42 es

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

SECTION SECTION SECTION EATON 2016 Arrow Hart Buyers Guide

SECTION SECTION SECTION EATON 2016 Arrow Hart Buyers Guide F SECTION SECTION SECTION 1 EATON 2016 Arrow Hart Buyers Guide www.arrowhart.com /arrowhart FSECTION Cam-Lok Single Pole Connectivity Table of contents Product selector guide F-3 NEMA rating system F-4

More information

Product Selection 3-Pole Contactors

Product Selection 3-Pole Contactors - Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 6A 200A 30A 200A Fusible Disconnect SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings

More information

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects Low Voltage Switches Enclosed switches - eot Manual motor controllers and disconnects The next generation of enclosed switches General information The eot series of enclosed manual motor controllers are

More information

Rotary Disconnect Switches, Bulletin 194R

Rotary Disconnect Switches, Bulletin 194R ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Rotary Disconnect Switches Bulletin 194R NOTICE: The specification guidelines in this document are intended to aid in the specification

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

Bulletin 140M Motor Protectors

Bulletin 140M Motor Protectors 0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected

More information

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions.

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions. Plugs & receptacles Cam-Lok single pole connectivity Cam-Lok Single pole connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok single pole connectivity

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Watertight Wiring Devices. A complete collection of watertight devices for demanding industrial environments wetguard

Watertight Wiring Devices. A complete collection of watertight devices for demanding industrial environments wetguard Watertight Wiring Devices A complete collection of watertight devices for demanding industrial environments wetguard 2 wetguard Leviton s Wetguard products are the most versatile and well-engineered watertight

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere

More information

A302DN.40/.63A Thermal Current Motor Starter

A302DN.40/.63A Thermal Current Motor Starter 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality Individual & fixed capacitor banks Low Voltage L O W V O L T A G E N E T W O R K Q U A L I T Y Individual & fixed bank Capacitors Description High reliability Well proven features of ABB dry type power

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame Vol. 1, Ref. No. 10499) Product Selection Table 12-56. Types 12-33 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed

More information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 LPCC3 3A 600V TD Class CC Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPCC3

More information

Indoor use primarily to provide protection against contact with the enclosed equipment and against a limited amount of falling dust.

Indoor use primarily to provide protection against contact with the enclosed equipment and against a limited amount of falling dust. TECHNICAL REFERENCE Have a Technical question? Don t worry. Here in the c3controls Technical Reference section, you ll find all the information you need to help you make the right decision for your particular

More information

GE 8000-Line Motor Control Centers

GE 8000-Line Motor Control Centers GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 00A 30A 00A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

KT7. Methods. of Applying. & Molded Case Circuit Breakers F119. Motor Circuit Controllers

KT7. Methods. of Applying. & Molded Case Circuit Breakers F119. Motor Circuit Controllers Methods of Applying KT7 & Molded Case Circuit Breakers This information is provided to aid in proper system design and utilization of the KTA7, KTB7 & KTC7 Controller in North American applications. UL

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

UL 508 Non-Fusible Disconnect Switches

UL 508 Non-Fusible Disconnect Switches UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.

More information

Disconnect switches Non-fusible Fusible Enclosed

Disconnect switches Non-fusible Fusible Enclosed Disconnect switches Non-fusible Fusible Enclosed Low voltage disconnect switches from ABB ABB is committed to offering high quality and innovative low voltage products. ABB s disconnect switch lines are

More information

Switchboards Instant Service

Switchboards Instant Service January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001 2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

Enclosed Molded Case Circuit Breakers

Enclosed Molded Case Circuit Breakers Enclosed Motor Controllers and Molded Case Circuit Breakers KTA7 Type-E Self Protected Manual Motor Controllers Page 89 Explosion-Proof Motor Controllers KTA7_EX Page 9 The following pages contain a selection

More information