Big performance in a small package

Size: px
Start display at page:

Download "Big performance in a small package"

Transcription

1 11 Series 11 Fusible up to 800A & Non fusible up to 1200 Amps Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or Fusible Which is Best For Your Application? Application Data Typical Control Switch Typical oad Break Switch Typical Fusible Switch To learn the basic differences between control, load and fusible disconnect switches and how to apply them, ask your Sprecher + Schuh representative for publication no: Tech-MSD Sprecher + Schuh s 11 series of fused and nonfused disconnect switches complies with U98 service entrance requirements and is NFPA 79 complaint. This family of rod operated switches is suitable for applications that require small panel space and superior short circuit protection. Big performance in a small package 11 disconnects are rated up to 1200A and can be operated at up to 600V. They protect motors up to 500HP (@480V). The 11 may be installed on circuits capable of delivering up to 200,000A of short circuit fault current levels typically found in modern industrial facilities. The 11 30A & 60A fusible switches incorporate removable fuse carriers with an optional neon blown fuse indicator carrier. This range of switches and handles also features a Test mode for circuit testing via D7 contact blocks. These switches can be conveniently DIN-rail mounted or screw mount. The new expanded offering of the 11 disconnect series ranges from 100A through 1200A. The 11 Fusible switches are available from 100A up to 800A which are designed to be used with Class J & fuses. The 11 Non-Fusible switches are available from 100A up to 1200A. Optional auxiliary contacts can also be mounted on the switch for control circuit use. The 11 family performance comes in a compact design, leaving room for additional branch circuit components within the panel. Maximum protection for downstream equipment 11 switches are U98 as a branch circuit protection device and is engineered to provide excellent short-circuit protection for downstream equipment up to 200kA. The 11 fusible switches accept the latest smalldimension Class CC, J, and HRCII fuses. This Type 2 protection limits let-through currents to levels specified for IEC equipment, and ensures that when the short circuit is cleared, the device will be operable. Meets the toughest safety standards The 11 offers a modular universal internal handle which provides an interlocked handle for test mode use (30A/60A) and U508A and NFPA 79 compliance in North America. The 11 30A & 60A is equipped with removable fuse carriers which provide dead-front switch protection during fuse change-out. Fuse carriers with neon blown fuse indicators are also available as an option on 30A &60A models. Test mode D7 auxiliary contacts may be installed to provide test capability of control circuit without energizing the main contacts for the 11-30A/60A swicthes. The 11 switches meet IP20 for finger-safe wiring terminals and IP30 for touch-safe fuse carriers. NFPA 79 Compliant All 11 30/60A & A 800A Fusible switches are NFPA79 compliant, which meets the following guidelines under the NFPA 79 standards and The supply Circuit ing Device shall: Be provided with a permanent means permitting it to be locked in the open position only independent of the door position. Be operable, by qualified persons, independent of the door position without the use of accessory tools or devices. The interlocking means shall: Be reactivated automatically when the door is closed. Prevent closing of the disconnecting means while the enclosure door is open, unless an interlock is operated by deliberate action. International standards and approvals All Sprecher + Schuh 11 disconnect switches are U isted under File Number E47426, CSA, CE Marked and are designed to meet IEC 947-3, and applicable NEMA requirements. 28

2 Series 11 U/CSA Fused ➎ Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (A) 120V 240V 240V 480V 600V 125V 250V Catalog Number Price U Class CC and CSA HRCI-Misc Fuses ➋ C A1 U Class J and CSA HRCI-J Fuses ➋ J A J B1 30A & 60A Typical J F5 200 ~ J F6 400 ~ J F7 600 ~ ~ ~ ~ 11-J F8 U Class and CSA HRCII- Fuses 800 ~ ~ ~ ~ F9 CSA HRCII-C Fuses 11-J100A...800A Typical H B H B1 Items in Gray available by Special Order only. Dimension Code U/CSA Non-Fused ➌ ➍ Maximum Horsepower Amp No. 1 Ø (60Hz) Three Phase (60Hz) DC Rating of Switch (A) 120V 240V 240V 480V 600V 125V 250V Poles Catalog Number Price N A N B NU F1 Dimension Code 30A & 60A Typical 200 ~ NU F1 NU100A A Typical 400 ~ ~ NU F2 600 ~ ~ NU F3 800 ~ ~ ~ ~ 3 11-NU F ~ ~ ~ ~ 3 11-NU F4 Updated Ordering Instructions Specify Switch catalog number (this page) Specify desired switch handle catalog number (page 31) Specify desired operating shaft catalog number (page 32) Specify desired accessories (starting on page 33) ➊ Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower rating. ➋ Only U listed Class CC, J and CSA Certified HRCI-J fuses are suitable for use with these disconnect switches. ➌ Non-fused disconnect switches must use separately installed fuses for upstream short circuit protection. ➍ 30A U-rated device has Ithe of 40 A per IEC. 60A U-rated device has Ithe of 80A per IEC. ➎ To order a fusible switch with fuse status indicator on 30A and 60A switches, add an S to the end of the catalog number and apply adder from list below. For example, $335 changes to $349. For 11-C30/J30 Add $14.00 For 11-J60/H30/H60 Add $18.00 Not available on J100 J600, or 800 devices

3 Series 11 Accessories 4th-Pole Modules (for 30A & 60A only) ➍ Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 240V 480V 600V 125V 250V Fuses Catalog Number Price U Class CC and CSA HRCI-MISC Fuses Dimension Code A CC, HRCI-Misc NC 80 A1 U Class J and CSA HRCI-J Fuses A J, HRCI-J NJ 80 A A J, HRCI-J NJ 100 B NJ CSA HRCII-C Fuses 30A ~ ~ HRCII-C ~ ~ Non-Fused 60A HRCII-C NH 80 B NH 100 B1 30 ➋ ~ NN 64 A NN 60 ➌ ~ NN 84 B2 Items in Gray available by Special Order only. 4th-Pole Modules must be ordered separately and field installed to existing 11 Switch NN 11-N Replacement Mounting Hardware Accessory Switch Dimension Description Code Pkg Qty Catalog Number Price (1) set screw, (1) shaft clip, and (2) #8 M4 screws A1, A HDWR 3.50 (1) set screw, (1) shaft clip, and (4) #8 M4 screws B1, B HDWR 5 (8) HM10 25mm bolts, (8) HM10 nuts, (16) M10 washers F HF-200-4U 257 (8) HM12 30mm bolts, (8) HM12 nuts, (16) M12 washers F HF-400-4U 406 (8) HM16 16mm bolts, (8) HM10 nuts F HF-250-3BDU 99 (8) HM8 16mm bolts, (8) HM8 washers, (6) HM10 35mm bolts, (6) M10 nuts, (12) M10 washers F HF-400-3BU 406 (8) HM12 30mm bolts, (8) HM12 nuts F8, F HF-800-3U 274 ➊ Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower rating. ➋ 30A U-rated device has Ithe of 40 A per IEC. ➌ 60A U-rated device has Ithe of 80A per IEC. 30 Discount Schedule B-5 ➍ To order a 4th pole module for 30A or 60A switches with fuse status indicator, add an S to the end of the catalog number and apply adder from list below. For example, $80 changes to $94. For NC/NJ Add $14.00 For NH/60-NJ/NH Add $18.00 Not available on J100 J600, or 800 devices.

4 Series 11 Accessories Switch Handle Assemblies (accepts 3 Padlocks) Switch Handle Assembly ➊➋ Description For use with Color Degree of Protection Catalog Number Price 11-PY Padlockable Handle - Standard 80 x 114 mm Configurable for defeatable or non-defeatable ➌ A Black Type 3R, 3, 12, 4, 4X 11-PB 53 Red/Yellow Type 3R, 3, 12, 4, 4X 11-PY PBT Padlockable Handle - Test Mode 80 x 114 mm Configurable for defeatable or non-defeatable ➌ A Black Type 3R, 3, 12, 4, 4X 11-PBT 56 Red/Yellow Type 3R, 3, 12, 4, 4X 11-PYT 56 Black Type 1, 3R, 12, 4, 4X IP66 10-HM4 104 Operating Handle Standard orientation with defeater A Red/Yellow Type 1, 3R, 12, 4, 4X IP66 10-HM4E HM4 Operating Handle Standard orientation with defeater A Black with light grey Type 1, 3R, 12, 4, 4X IP65 11-HM4-141 Red/Yellow Type 1, 3R, 12, 4, 4X IP65 11-HM4E HM4- Operating handle Standard orientation without defeater A Black with light grey Type 1, 3R, 12, 4, 4X IP65 11-HM4-N2-141 Red/Yellow Type 1, 3R, 12, 4, 4X IP65 11-HM4E-N HM4-N2- OSHA ock Out/Tag Out Compliance (OTO) OSHA CFR36 Section 1910 mandates that disconnects be able to be locked out while in the OFF position during servicing. All 11 handles comply with this important safety requitement. Please see NFPA Article 430 for disconnect requirements of motor applications. 11 Discount Schedule B-5 ➊ Mounting screws included with Switch Handle Assembly. ➋ ockable in OFF position (and ON position with special modification). ➌ Switch handle can be field modified to be defeatable or non-defeatable. 31

5 Series 11 Accessories Metal Operating Shafts ➊ Shaft (typical) For use with handle type Operating Shaft ength mm (in) Catalog Number Price 11-S1 S2 11-P/11-P_T for A 10-HM for A 305 (12) 11-S (21) 11-S (12.6) 11-R (22.8) 11-R HM for fused A 320 (12.6) 11-R (22) 11-R R7 R8 11-R9 R12 11-HM for Non-fused A 320 (12.6) 11-R (22) 11-R10 84 NFPA 79 Handle Kit - Internal handle that permits operation of the disconnect when the panel door is open, in compliance with NFPA79. Includes NFPA 79 internal operating handle with shaft ➋ 11-P/11-P_T 10-HM4 (11 fused A) 11-HM4_- (11 fused A) 305 (12) 11-N (21) 11-N (12.6) 11-HM4-NFPA (22) 11-HM4-NFPA (12.6) 11-HM4-NFPA (22) 11-HM4-NFPA4 252 Operating Shaft Accessories Accessory Description Switch Dimension Code Pkg Qty Catalog Number Price Operating Shaft Coupler - Used with 11-S1 and 11-S2 shafts to extend shaft length an additional 120 mm (4.75 in). A1, A2, B1, B SC ➊ See page 40.4 for Shaft dimensions. ➋ The 11-NU100 NU1200 Non-Fused switches do not have a means to be locked in the OFF position, therefore are not in compliance with NFPA79 and should not be used with 11-HM4-NFPA* handle kits. 32 Discount Schedule B-5 Updated

6 Series 11 Accessories Switch Padlock Accessory (for 30A & 60A only) ➊➎ Accessory Description Switch Dimension Code Pkg Qty Catalog Number Price Swith Padlock Accessory A1, A2, B1, B PA1 13 Replacement Fuse Carriers (for 30A & 60A only) Without Fuse Status Indication With Fuse Status Indication Accessory Description Pkg Qty Catalog Number Price Catalog Number Price 30A CC Fuse Carrier 1 11-C30-FC C30-FCS 34 30A J Fuse Carrier 1 11-J30-FC J30-FCS 34 Neon Fuse Status Indication 11-J30-FC 60A J Fuse Carrier 1 11-J60-FC J60-FCS 44 30A CSA HRCII-C Fuse Carrier 1 11-H30-FC H30-FCS 33 60A CSA HRCII-C Fuse Carrier 1 11-H60-FC H60-FCS 44 30A Non-Fuse Carrier 1 11-N30-FC J30-FCS Items in Gray are Special Order. 60A Non-Fuse Carrier 1 11-N60-FC 28 Auxiliary Contact Blocks Accessory Description For use with... Contact Material Contact Block ➋➌ Note: Sold only in multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces. Auxiliary Contact Block ➍ N.O./N.C. All A All Fusible switches A All 11 Non-Fused A N.O. N.C. N.O.E.M. N.C..B. N.O. w/ spring-clamp N.CO. w/ spring-clamp Pkg Qty 10 Catalog Number D7-X10 D7-X01 D7-X10E D7-X01 D7-Q10 D7-Q01 Price See Section H STNONC NDNONC ➊ For Padlock with ø3 6mm. ➋ Also used for test mode function on 30A 60A switches. ➌ Maximum auxiliary contact blocks allowed to be mounted on switches: Max 6 for 30A 60A switches Max 4 for 11-J A switches Max 8 for 11-J400 J600, & 800 switches Discount Schedule B-5 ➍ Only one auxiliary type can be mounted on switch. Auxiliaries cannot be combined. ➎ Fusible A has built in lockable feature on switch. 33

7 Series 11 Accessories Terminal Protective Covers ➊➋ Accessory Description No. of Poles Mounting Position Switch Dim. Code Qty req. per switch Pkg Qty Catalog Number Price 30A Terminal Shroud 3 60A Terminal Shroud 3 30A Terminal Shroud 1 60A Terminal Shroud 1 line or load side line or load side line or load side line or load side A1, A C B1, B C A1, A C B1, B C U Terminal Shroud for 11- U Fused 600A 800A U Terminal Shroud for 11- U Fused 200A U Terminal Shroud for 11 - U Fused 400A U Terminal Shield for line or load side line or load side line or load side F NC F NC F NC U Non-fused 100A 200A 3 line side F NC load side F NC18 34 U Non-fused 400A 3 line side F NC load side F NC21 83 U Non-fused 600A 3 line or load F NC U Non-fused 800A 1200A 3 line or load F NC Multi-Tap Terminal ugs ➊ Accessory Description For 30A 11 Wire: (3) 8-14 AWG/ mm 2 Torque: 14 lb-in/1.6 Nm For 60A 11 Wire: (3) 4-14 AWG/2-25 mm 2 Torque: 24 lb-in/2.8 Nm Switch Dimension Code Pkg Qty Catalog Number Price A1, A MT3 27 B1, B MT ➊ Includes integral plastic cover (not shown), for IP10 ingress rating only. ➋ Terminal Protective Covers shipped with 11 switches: A Optional 11-J Optional 11-J NC29 (3 pcs) NC29 (3 pcs) 11-NU Optional 11-NU NC23 (1 pc) 11-NU NC25 (1 pc) 33.1 Discount Schedule B-5

8 Series 11 Accessories Terminal ug Kits Accessory For use with Wire Size Pkg Qty Catalog Number Price 11 U Non-Fused A, Fused 200A (1) 300 MCM 3 11-T U Fused and Non-Fused 400A (1) 600 MCM 3 11-T U Fused and Non-Fused 400A (2) 350 MCM 3 11-T U Fused A and Non-Fused 600A (2) 600 MCM 3 11-T U Non-Fused A (2) 600 MCM 6 11-T9 752 Cable-Operated Kits (for A switches) AVAIABE 2013 Accessory Description Cable length Catalog Number Price Cable-operated disconnect switch with handle Cable-operated disconnect kit with interlock Open switches Compatible with all 11 30A and 60A fused and non-fused disconnects (sold separately) Uses 11 handles (sold separately) IP66 (Type 3R, 3, 12, 4, 4X) Padlockable handle mounts to flange-styled enclosures Cable options available in 3 10 ft. lengths NFPA 2002 Compliant 3 ft 11-FC ft 11-FC ft 11-FC ft 11-FC Side-Mounted Switch Kit (for A switches) Accessory Description For use with... Catalog Number Price NFPA 79 Compliant IEC Fused and Non-Fused s, Side-Mounted Kit Used with all 30/60A fused and non-fused disconnects and 11-P handles (both sold separately) Open switches Operating handle ingress ratings: IP66 (Type 3R, 3, 12, 4, 4X) Padlockable handle AVAIABE SDK1 side-mount handle provides NFPA 79 compliancy with a bracketed switch and interlock system. The 11-P rotary handle is mounted to the side of the enclosure and attaches to the 11 next generation disconnect and interlock mechanism. The side handle remains connected to the switch and interlock mechanism at all times. This solution provides the single, side handle design with the NFPA 79 compliancy of the secondary interlock. This kit is used with the 11-P family of disconnect handles (sold separately) /60A disconnect switches and 11-P handles 11-SDK Updated Discount Schedule B

9 Series Enclosed Motor s (U and CSA Approved Enclosures) Type 3/4/12 Watertight, Dusttight Sheetmetal Enclosure Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure Type 4/4X Watertight, Corrosion-Resistant Non-metallic Enclosure Amp/Horsepower Rating U/ CSA Amps 1Ø (60 Hz) Horsepower 3Ø (60 Hz) Dimension Code 120V 240V 240V 480V 600V Catalog Number Price Catalog Number Price Catalog Number Price Class CC Fused Dimension Code Dimension Code FC030P3 827 A1 11-CC030P A1 11-KC030P3 830 A1 Class J Fused FJ030P3 847 A1 11-CJ030P A1 11-KJ030P3 850 A FJ060P B1 11-CJ060P B1 11-KJ060P B FJ100P C1 11-CJ100P C1 11-KJ100P C1 200 ~ FJ200P D1 11-CJ200P D1 11-KJ200P D1 400 ~ FJ400P F1 11-CJ400P F1 11-KJ400P F1 Non-Fused FN030P3 561 A2 11-CN030P A2 11-KN030P3 561 A FN060P3 993 B2 11-CN060P B2 11-KN060P3 993 B FN100P C1 11-CN100P C1 11-KN100P C1 200 ~ FN200P D1 11-CN200P D1 11-KN200P D1 400 ~ ~ FN400P F1 11-CN400P F1 11-KN400P F1 NOTE: All Enclosed s come standard with a black handle with ON/OFF marking. For a yellow and red handle, add suffix E to the end of the catalog number. Example: change 11-FN030P3 to 11-FN030P3E. 11 arger sizes available. Contact your Sprecher + Schuh representative. 11-KJ060P3 34

10 Application Methods Series 11 Applications Within the United States and Canada General The requirements for disconnect switches used in motor branch circuits rated 600V and less are defined in Article 430, Part J of the U.S. National Electrical Code (NEC), NFPA70. Canadian Electrical Code (CEC) requirements are very similar in the area of motor branch circuit disconnect requirements. For simplicity, we will treat the NEC and CEC requirements as being the same and reference specific sections of the US National Electrical Code. The requirements for properly sizing a disconnect switch are dependent on the type of application. The NEC refers to two types of applications: single motor and combination loads. A combination load consists of an application where two or more motors are used together or where one or more motors are used in combination with other loads, such as resistance heaters. Single Motor Applications Section Paragraph (a) states that the disconnect switch must have an ampere rating of at least 115% of the full load current rating of the motor. Example 1: for a motor with a full-load current of 22A, the disconnect switch must be rated at least 25.3A (22 x 1.15). current is the sum of the simultaneously started motors locked-rotor currents and the full-load currents of the remaining operating motor and non-motor loads. The disconnecting means shall have a current rating equal to or greater then 115% of the equivalent single motor full-load current and have a horsepower rating equal to or greater than the horsepower rating determined from the equivalent locked-rotor summation. Consider the following 460V application: oad HP Full-oad Current A Motor (simultaneous) Motor (not included) ➊ Motor (simultaneous) Motor (simultaneous) Other 7.0 (simultaneous) Total Equivalent 62.6 (simultaneous) ➊ Motor 2 is not included in the total since it cannot operate simultaneously with the other motor, therefore, the disconnect switch must be rated at least 72A (1.15 x 62.6). If the disconnecting means under evaluation is rated in horsepower, the selection of the disconnect switch is even more straightforward; a disconnect switch must have a horsepower rating equal to, or greater than the horsepower rating of the motor at the applicable voltage. Example 2: For a motor with a 10HP rating at 460V AC, the disconnect switch must be rated at least 10HP at 460V AC. If the disconnect switch is rated in horsepower, and U isted, U Component Recognized, or CSA Certified, it will meet the requirements for the 115% full-load current rating stipulated by the NEC. Combination oad Applications Section Paragraph (c) addresses the rating of the disconnecting means for combination loads. This paragraph essentially requires that the loads that may be simultaneously on a single disconnecting means be combined to provide equivalent full-load and locked-rotor currents for what is then to be considered as a single motor for the purpose of selecting the appropriate disconnecting means. This means that it is necessary to identify the particular combination of connected loads which can be operating simultaneously and will result in the maximum full-load and locked-rotor current sums. The individual full-load current values are to be selected from Tables , , or and the locked-rotor values are to be from Table The equivalent single motor full-load current is the sum of the simultaneously operating motor full-load currents and the rating in amperes of the other loads operating at the same time. The equivalent locked-rotor Consider now the locked-rotor current analysis for the same application: oad HP ocked Rotor Current A Motor 1 5 (7.6 FA) 45.6 (simultaneous) Motor (not included) ➊ Motor (simultaneous) ➋ Motor (simultaneous) ➋ Other 7.0 (simultaneous) Total Equivalent (simultaneous) ➊ Note again that Motor 2 cannot operate simultaneously with the other loads. ➋ The largest equivalent locked-rotor current occurs when motors 3 and 4 start together while the other loads marked simultaneous are already operating. Since Motor 1 is not starting with Motors 3 and 4, its full-load current will be added to the total instead of its locked-rotor current. Table , which provides the correlation between locked-rotor currents and HP ratings, shows that a 40 HP rating is the equivalent for locked-rotor amperes. Therefore, the disconnect selected for this application must have a current rating of at least 72A and a HP rating of at least 40 HP. In this case, an 10 disconnect switch rated for 100A and 60 HP at 460V would be an appropriate choice. What can be seen from this analysis is that, depending upon the number of motors that can start simultaneously, the actual size of the required disconnect is sometimes determined by the equivalent full load current (72A) and other times by the equivalent horsepower determined from the locked-rotor analysis (40 HP)

11 Technical Information IP Ratings Definitions IP Ratings Definitions IP Ratings Definitions The first IP number (left side of chart) is protection against solid objects. The second IP number (across top) is protection against liquids. The chart itself shows degrees of protection according to IEC 529. No protection Protected against vertically falling drops of water (condensation) Protected against dripping water with enclosure up to 15 from vertical Protected against sprayed water up to 60 from vertical Protected against sprayed water from all directions (limited ingress permitted) Protected against low pressure water jets from all directions (limited ingress permitted) Protected against strong jets of water from all directions Protected against immersion up to one meter Protected against long periods of immersion under pressure IP 0 IP 1 IP 2 IP 3 IP 4 IP 5 IP 6 IP 7 IP 8 1 meter IP0 IP00 No protection IP1 Protected against solid objects up to 50mm (accidental touch by hands) IP2 Protected against solid objects up to 12mm (fingers, knuckles) IP3 IP10 IP11 IP12 IP20 IP21 IP22 IP23 IP30 IP31 IP32 IP33 IP34 11 Protected against solid objects up to 2.5mm (tools, wires) IP4 Protected against solid objects up to 1mm (wires) IP5 Protected against dust (limited engress permitted) IP6 IP40 IP41 IP42 IP43 IP44 IP50 IP53 IP54 IP55 IP56 IP60 IP65 IP66 IP67 Totally protected against dust 34.2

12 Technical Information Ratings Definitions NEMA / U Type Definitions NEMA / U Type Indoor Use Outdoor Use Indoor or Outdoor Use For a degree of protection against: R 3 4 4X 6P 6 Incidental contact with enclosed equipment Falling dirt Rust Circulating dust, lint, fibers and flyings Windblown dust Falling liquids and light splashing Rain (limited water allowed inside) Rain (no water allowed inside) Snow and sleet Hosedown and splashing water Occasional prolonged submersion Oil or coolant spraying or splashing Corrosive agents Occasional temporary submersion

13 Technical Information Series 11 Fused for U Class Fuses and CSA HRCI-J Electrical Ratings 11-C J J U Fuse Type / CSA Fuse Type Class CC/HRCI- MISC ➊ Class J/HRCI-J Class J/HRCI-J Maximum Fuse Cartridge Size (A) Maximum Voltage AC DC (V) (V) Ampere Rating (A) Maximum Short Circuit Prospective Fault Current (ka) Fuse Operating Characteristics Time Delay Non- Time Delay Time Delay Non- Time Delay Time Delay Maximum Hp, 3Ø AC 200V 60 Hz (Hp) V 60 Hz (Hp) V 60 Hz (Hp) V 60 Hz (Hp) Maximum Hp, 1Ø AC 120V, 60 Hz (Hp) V, 60 Hz (Hp) Maximum Hp, DC 125V, DC (Hp) V, DC (Hp) Non- Time Delay Mechanical Data 11-C J J Degree of Protection (per IEC ) Switch Only IP20 IP20 IP20 Switch with Terminal Shield & Fuse Carriers IP20 IP20 IP20 Mechanical Endurance ➋ Operations 10,000 10,000 10,000 Handle Mechanism Operating Torque N m lb in Terminal Capacity Power Terminals mm AWG #14 #8 #14 #8 #14 #4 Auxiliary Contact Terminals mm AWG #14 #12 #14 #12 #14 #12 Maximum Number of Auxiliary Contacts Approximate Weight kg lbs Minimum Enclosure Size Height 248 (9-3/4) 248 (9-3/4) 248 (9-3/4) Approximate dimensions in Width 171 (6-3/4) 171 (6-3/4) 197 (7-3/4) millimeters (inches) Depth 148 (5-13/16) 148 (5-13/16) 148 (5-13/16) Switch Dimensions Reference (See dimension drawings) A1 A1 B Updated ➊ CSA HRCI-MISC fuses must also be U isted as Class CC fuses. ➋ Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC , and U

14 Technical Information Series 11 Fused for U Class Fuses and CSA HRCI-J Electrical Ratings 11-J J J J U Fuse Type / CSA Fuse Type Class J/HRCI-J Class Maximum Fuse Cartridge Size (A) Maximum Voltage AC DC (V) (V) ➋ ➋ ➋ ➋ Ampere Rating (A) Maximum Short Circuit Prospective Fault Current (ka) Fuse Operating Characteristics Maximum Hp, 3Ø AC 200V 60 Hz (Hp) ~ ~ ~ ~ ~ 240V 60 Hz (Hp) V 60 Hz (Hp) V 60 Hz (Hp) Maximum Hp, 1Ø AC 120V, 60 Hz (Hp) 7.5 ~ ~ ~ ~ 240V, 60 Hz (Hp) ~ ~ Maximum Hp, DC 125V, DC (Hp) ~ ~ 250V, DC (Hp) ~ ~ ➋ 11 Mechanical Data 11-J J J J Degree of Protection (per IEC ) Switch Only IP20 IP20 IP20 IP20 IP20 Switch with Terminal Shield & Fuse Carriers IP20 IP20 IP20 IP20 IP20 Mechanical Endurance ➊ Operations 10,000 8,000 6,000 5,000 5,000 Handle Mechanism Operating Torque N m lb in Terminal Capacity 600 MCM; 2 x Power Terminals mm MCM 300 MCM 2 x 600 MCM 2 x 600 MCM AWG #1 #6 #2 or 2 x #6 2 x #2 2 x #2 Auxiliary Contact Terminals mm AWG #14 #12 #14 #12 #14 #12 #14 #12 #14 #12 Maximum Number of Auxiliary Contacts Approximate Weight kg lbs Minimum Enclosure Size Height Approximate dimensions in Width ~ ~ ~ ~ ~ millimeters (inches) Depth Switch Dimensions Reference (See dimension drawings) F5 F6 F7 F8 F ➊ Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC ➋ 3-Poles in series. 36 Updated

15 Technical Information Series 11 Non-Fused for CSA and U Class Applications ➊ Electrical Ratings 11-N N NU NU Maximum Voltage AC DC (V) (V) Fuse Type ~ ~ J J Ampere Rating (A) 30 ➋ 60 ➋ Maximum Short Circuit Prospective Fault Current (ka) Fuse Operating Characteristics ➌ Time Delay Non- Time Delay Time Delay Non- Time Delay ~ ~ Maximum Hp, 3Ø AC 200V 60 Hz (Hp) ~ ~ 240V 60 Hz (Hp) V 60 Hz (Hp) V 60 Hz (Hp) Maximum Hp, 1Ø AC 120V, 60 Hz (Hp) ~ 240V, 60 Hz (Hp) Maximum Hp, DC 125V, DC (Hp) V, DC (Hp) Power ost (W) 2 6 ~ ~ Mechanical Data 11-N N NU NU Degree of Protection (per IEC ) Switch Only IP20 IP20 IP20 IP20 Switch with Terminal Shield & Fuse Carriers IP20 IP20 IP20 IP20 Mechanical Endurance ➌ Operations 10,000 10,000 10,000 10,000 Handle Mechanism Operating Torque Terminal Capacity N m lb in Power Terminals mm MCM 300 MCM AWG #14 #8 #14 #4 #6 #6 Auxiliary Contact Terminals mm AWG #14 #8 #14 #4 ~ ~ Maximum Number of Auxiliary Contacts Approximate Weight kg / /2.1 lbs / /4.3 Minimum Enclosure Size Height 248 (9-3/4) 248 (9-3/4) Approximate dimensions in Width 171 (6-3/4) 197 (7-3/4) ~ ~ millimeters (inches) Depth 111 (4-3/8) 111 (4-3/8) Switch Dimensions Reference (See dimension drawings) A2 B2 F1 F Updated ➊ Non-fused disconnect switches must be used with separately installed fuses. ➋ When using CSA HRCI-J, HRCI-MISC (also U isted as Class CC) or HRCI-T fuses, and U Class J, CC or T fuses. ➌ Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC , U 1087 and U

16 Technical Information Series 11 Non-Fused for CSA and U Class Applications ➊ Electrical Ratings 11-NU NU NU NU Maximum Voltage AC DC (V) (V) Fuse Type J J Ampere Rating (A) Maximum Short Circuit Prospective Fault Current (ka) Fuse Operating Characteristics ➌ ~ ~ ~ ~ Maximum Hp, 3Ø AC 200V 60 Hz (Hp) ~ ~ ~ ~ 240V 60 Hz (Hp) V 60 Hz (Hp) V 60 Hz (Hp) Maximum Hp, 1Ø AC 120V, 60 Hz (Hp) ~ ~ ~ ~ 240V, 60 Hz (Hp) ~ ~ ~ ~ Maximum Hp, DC 125V, DC (Hp) ~ ~ 250V, DC (Hp) ~ ~ Power ost (W) ~ ~ ~ ~ Mechanical Data 11-NU NU NU NU Degree of Protection (per IEC ) Switch Only IP20 IP20 IP20 IP20 Switch with Terminal Shield & Fuse Carriers IP20 IP20 IP20 IP20 Mechanical Endurance ➌ Operations 6,000 6,000 3,500 3,500 Handle Mechanism Operating Torque Terminal Capacity N m lb in Power Terminals mm MCM 2 x 600 MCM 4 x 600 MCM 4 x 600 MCM AWG #2 2 x #2 4 x #2 4 x #2 mm Auxiliary Contact Terminals AWG ~ ~ ~ ~ Maximum Number of Auxiliary Contacts Approximate Weight kg 3/ / / /14.5 lbs 6.6/ / / /32 Minimum Enclosure Size Height Approximate dimensions in Width ~ ~ ~ ~ millimeters (inches) Depth Switch Dimensions Reference (See dimension drawings) F2 F3 F4 F ➊ Non-fused disconnect switches must be used with separately installed fuses. ➋ When using CSA HRCI-J, HRCI-MISC (also U isted as Class CC) or HRCI-T fuses, and U Class J, CC or T fuses. ➌ Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC , U 1087 and U Updated

17 Technical Information Series 11 Fused for CSA HRCII-C Fuses Electrical Ratings 11-H H CSA Fuse Type/U Fuse Type HRCII-C HRCII-C Maximum Fuse Cartridge Size (A) Maximum Voltage AC (V) Ampere Rating (A) Maximum Short Circuit Prospective Fault Current (ka) Fuse Operating Characteristics Maximum Hp, 3Ø AC 200V 60 Hz (Hp) V 60 Hz (Hp) V 60 Hz (Hp) V 60 Hz (Hp) Maximum Hp, 1Ø AC 120V, 60 Hz (Hp) V, 60 Hz (Hp) 3 10 Mechanical Data 11-H H Degree of Protection (per IEC ) Switch Only IP20 IP20 Switch with Terminal Shield & Fuse Carriers IP20 IP20 Mechanical Endurance ➊ Operations 10,000 10,000 Handle Mechanism Operating Torque N m lb in Terminal Capacity Power Terminals mm AWG #14 #8 #14 #4 Auxiliary Contact Terminals mm AWG #14 #12 #14 #12 Maximum Number of Auxiliary Contacts 6 6 Approximate Weight kg lbs Minimum Enclosure Size Height 248 (9-3/4) 248 (9-3/4) Approximate dimensions in Width 171 (6-3/4) 197 (7-3/4) millimeters (inches) Depth 148 (5-13/16) 148 (5-13/16) Switch Dimensions Reference (See dimension drawings) B1 B Updated ➊ Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC , U 1087 and U

18 Technical Information Series 11 Environmental Data For All 11 Fused and Non-Fused Environmental Ratings 11-_30A 60A 11-_100A 1200A ➊ Ambient Temperature Open [ C (F)] ( ) ( ) Enclosed [ C (F)] ( ) ( ) Storage [ C (F)] ( ) ( ) Altitude (per IEC ) [m] 2,000 2,000 Relative Humidity (per IEC ) 90% at +20 C (+68 F) 90% at +20 C (+68 F) 50% at +40 C (+104 F) 50% at +40 C (+104 F) Standards Compliance IEC /EN BS EN VDE 0660 CSA 22.2 No. 4 NEMA KS-1 U 98 with 11-SDK1 Handle Kit U 98 CSA 22.2 No. 4 Certifications U isted (File No. E 47426, Guide WHTY) CSA Certified (File No. R1234) CE ASTA Certified OVAG Certified with 11-SDK1 Handle Kit U isted (File No. E47426, Guide WHTY) CSA Certified (File No. R1234) CSA HRCII Fuses (sold by others) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 11 CSA fuse type: HRCII-C Voltage rating: 600V AC Interrupting rating: A Standard cartridge sizes: 30, & 60 A Typical ampere ratings: 1 60 A Construction: Blade type for bolted connection Can be installed on Bulletin 194R disconnect switch Cat. Nos: 11-H , 11-H Where used: Canada Current Range [A] A B C D E F G H J (3-5/16) (2-51/64) 50.8 (2) (13/16) 8.73 (11/32) 7.54 (19/64) 5.56 (7/32) (15/16) 1.59 (1/16) (3-1/2) (2-51/64) 50.8 (2) (13/16) 12.7 (1/2) 7.54 (19/64) 5.56 (7/32) (1-1/16) 1.59 (1/16) ➊ Derate switch 1% for every 1ºC over 40ºC 37.3 Updated

19 Technical Information Series 11 CSA HRCI Class CC Fuses (sold by others) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. U fuse type: Class CC CSA fuse type: HRCI-MISC Voltage rating: 600V AC Interrupting rating: A Standard cartridge sizes: 30 A Typical ampere ratings: 1 30 A Construction: Ferrule type Can be installed on 11-C disconnect switch Where used: North America CSA HRCI Class J Fuses (sold by others) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. CSA fuse type: HRCI-J U fuse type: Class J Voltage rating: 600V AC Interrupting rating: A Standard cartridge sizes: 30, 60, 100, 200, and 400 A Typical ampere ratings: A; Blade type for bolted connection Can be installed on 11 disconnect switch Cat. Nos: 11-J30 J Where used: North America

20 Technical Information Series 11 Wiring Diagrams U isted, CSA Certified Dimension Reference Circuit 11-C J J H H A1 A1 B1 B1 B1 11-N N A2 B NC/NJ/NH 3-Pole Switch + 4-Pole Module 11 38

21 Dimensions Series Fused and Non-Fused (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. D W FD 11 A E H C B Dimension Approximate Dimensions in mm (in) Reference H W D A B C ➊ E ➊ FD A1 108 (4-1/4) 120 (4-3/4) 101 (4) 90 (3-9/16) 105 (4-1/8) 85 (3-11/32) 82 (3-15/64) 2-M4, 2-#8 A2 108 (4-1/4) 120 (4-3/4) 80 (3-1/8) 90 (3-9/16) 105 (4-1/8) 85 (3-11/32) 82 (3-15/64) 2-M4, 2-#8 B1 113 (4-29/64) 142 (5-19/32) 114 (4-31/64) 100 (3-15/16) 120 (4-23/32) N/A N/A 4-M4, 4-#8 B2 113 (4-29/64) 142 (5-19/32) 93 (3-43/64) 100 (3-15/16) 120 (4-23/32) N/A N/A 4-M4,4-#8 ➊ Mounting holes are backward compatible with 10 39

22 Dimensions Series Fused (100A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes Fused (200A)

23 Dimensions Series Fused (400A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes ( 3P) (4P) 259 (3P) (4P) Fused ( A) min min (3P) (4P) 284 (3P) - (4P) Ø Ø (3P) (4P) 364 (3P) (4P)

24 Dimensions Series Non-Fused ( A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. M J1 U Z Y Terminal Shrouds W R1 H N AA AC V K AB R2 T F AD C N Dim. Ref. F1 400 F2 11-N Dim. Ref. F1 400 F2 Overall Approximate Dimensions in mm (in) Terminal Shrouds Switch Body Switch Mounting C AC AD F (3-pole) 94.6 (3.72) 94.6 (3.72) 128 (4.92) 256 (10.1) 256 (10.1) 406 (16) 77.5 (3.05) 77.5 (3.05) 115 (4.15) 180 (7.09) 180 (7.09) 230 (9.05) F (4-pole) 230 (9.06) 230 (9.06) 290 (11.4) H 107 (4.22) 107 (4.22) 166 (6.53) Approximate Dimensions in mm (in) Connection J1 (3-pole) 55 (2.17) 55 (2.17) 75 (2.95) J1 (4-pole) 105 (4.13) 105 (4.13) 135 (5.31) T U V W Y Z AA AB 50 (1.97) 50 (1.97) 65 (2.56) 25 (0.98) 25 (0.98) 45 (1.77) 30 (1.18) 30 (1.18) 50 (1.97) 11 (0.43) 11 (0.43) 13 (0.51) 3.5 (0.14) 3.5 (0.14) 5 (0.2) 34.4 (0.14) 34.4 (0.14) 53 (2.08) 160 (6.3) 160 (6.3) 260 (10.2) 15 (0.6) 15 (0.6) 20 (0.8) K 45.6 (1.8) 45.6 (1.8) 67.5 (2.65) M (3-pole) 160 (6.3) 160 (6.3) 210 (8.26) M (4-pole) 210 (8.7) 210 (8.7) 270 (10.6) N R1 R2 135 (5.31) 135 (5.31) 195 (7.67) 9 (0.35) 9 (0.35) 9 (0.35) 7 (0.27) 7 (0.27) 7 (0.27) 40.2 Updated

25 Dimensions Series Non-Fused (600A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. H Z J M Ø Ø 13 Y X AC N N1 AA F 11-N Dim. Ref. 600 F3 Approximate Dimensions in mm (in) Terminal Shrouds Switch Body Switch Mounting Connection AC F (3-pole) F (4-pole) H J (3-pole) J (4-pole) M (3-pole) M (4-pole) N N1 AA Z (18.12) (11) (14.17) (5.5) (5) (6.59) (10.03) (13.19) (6.88) (2.34) (12.6) (1.85) H Z 11 Non-Fused ( A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes Ø 0.43 Ø 11 J M AA AC Y X N1 N2 N AA F N Dim. Ref. F4 Approximate Dimensions in mm (in) Terminal Shrouds Switch Body Switch Mounting Connection AC F (3-pole) F (4-pole) H J (3-pole) J (4-pole) M (3-pole) M (4-pole) N N1 AA Z (18.12) (14.64) (19.37) (5.5) (6.83) (9.19) (13.66) (18.38) (6.88) (2.34) (13) (1.85) (18.12) (14.64) (19.37) (5.5) (6.83) (9.19) (13.66) (18.38) (6.88) (2.34) (13) (1.85) 40.3

26 Dimensions Series 11 Handles 11 Metal Operating Shaft Dimensions 11-S1..S2 11-R7..R8 11-R9..R12 A A B C Catalog Number A 2 mm (in) B mm (in) C mm (in) 11-S (0.238) 305 (12) 11-S (0.238) 533 (21) 11-R7 10 (0.39) 320 (12.6) ~ 11-R8 10 (0.39) 580 (22.8) ~ 11-R9 12 (0.47) 320 (12.6) 22 (0.87) 11-R10 12 (0.47) 560 (22) 22 (0.87) 11-R11 12 (0.47) 320 (12.6) 22 (0.87) 11-R12 12 (0.47) 560 (22) 22 (0.87) Typical View 11-P*/11-P*T Operating Handles Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes mm ( ) 80 (3.15) 114 (4.49) 72.3 (2.85) 26.7 (1.05) 25.4 (1) 11 Fron t of Cover ø 35 (ø 1.38) 76.7 (3.02) Front 34 (1.34) 50 (1.97) 25 (0.98) 25 (0.98) 50 (1.97) 51 (2.01) Right Side OR 25 (0.98) ø 35 (ø 1.38) 31.5 (1.24) 63 (2.48) (2) - ø 5.5 (0.22) (2) - ø 5.5 (0.22) 40.4

27 Dimensions Series 11 Handles 10-HM4/HM4E Operating Handles dia. dia. Operating Handles Cat. No. 10-HM4, -HM4E 11-HM4*-/-N2- Operating Handles Ø 78 (3.07) 0 90 I 4 Ø 7 (0.27) Ø 37 (1.46) 20 (0.78) 210 (8.27) 14 (0.55) 14 (0.55) 20 (0.78) (2.40) 40.5

28 Dimensions Series 11 Handles 11-N1 & 11-N2 Operating Handle (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. C 1 C C - D 2 3 Next Generation 11 egacy 10 C D C D 11-N30- > 165 mm 6.5 in 10-NN030 > 170 mm 6.75 in 11-B20-11-B32-11-C30-11-F25-11-F32-11-J30- > 190 mm 7.5 in 155 mm 6.0 in 10-NC NJ NA NA200 > 210 mm 8.25 in 140 mm 5.5 in 11-N60- > 180 mm 7.0 in 10-NN060 > 170 mm 6.75 in 11-B63-11-D32-11-D63-11-F63-11-H30-11-H60-11-J60- > 205 mm 8.0 in 170 mm 6.75 in 10-NJ NA300 > 210 mm 8.25 in 115 mm 4.5 in

29 AVAIABE 2013 Dimensions Series 11-FC_ Cable-Operated Handle 11-FC NFPA79 Cable-Operated Handle The 11-FC cable-operated disconnect with interlock provides a fully compliant solution to the 2002 changes in the National Fire Protection Association 79 (NFPA 79). The 11-FC combines the small size of the 11 IEC disconnect with the flexibility of a cable-operated mechanism to provide an NFPA 79 IEC solution for flange style enclosures. The 11-FC bracketed mechanism for and 60 A devices attaches to the 11 disconnect switch base and operates the ON-OFF action via cable to a standard 10/11 handle. The 11-FC handle/interlock mechanism provides the no-tools operation and the secondary interlock as required by NFPA changes. The 11-FC cable-operated disconnect is offered in 3 10 ft cable lengths, allowing a variety of placement options for the 11 disconnect within the enclosure. The handle (ordered separately) is available in 3 different styles: plastic, stainless steel, or painted metal. Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes (6) (4-7/8) mm (in.) 100 (3-15/16) (8) Ref (10) Min

30 AVAIABE 2013 Dimensions Series 11-SDK1 Side-Mounted Handle 11-SDK1 Side Mounted Handle The 11-SDK1 side-mount handle provides NFPA 79 compliancy with a bracketed switch and interlock system. The 10-HS rotary handle is mounted to the side of the enclosure and attaches to the 11 disconnect and interlock mechanism. The side handle remains connected to the switch and interlock mechanism at all times. This solution provides the single, side handle design with the NFPA 79 compliancy of the secondary interlock. This kit is used with the 10-HS family of disconnect handles (sold separately). Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. Hinge Side 38.1 (1-1/2) Enclosure Thickness mm (in) 15.9 (ø 9/16) 88.4 (3-31/64) 31.8 (1-1/4) Min. (6) 25 (63/64) 6.4 (1/4) 5.6 ø (ø 7/32) 2 Holes 22.2 (7/8) C Door Hook Defeater ever Interlock 5.6 ø (ø 7/32) 6 Holes 63.5 (2-1/2) 88.9 (3-1/2) 44.4 (1-3/4) 25 (63/64) 34.9 (ø 1-3/8) 50 (1-31/32) 50.8 (2) (4) (8-7/32) Ref. 50 (1-31/32) 89.4 (3-33/64) Hinge Side 51 (2.01) Door Hook P* Handle 40.8

31 Dimensions Series Enclosure and Operating Handle Dimensions Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. A 51 (2.01) C B F E D Catalog Number 11-C J Dimension Reference A B C D E F Maximum Minimum Minimum Maximum Minimum Minimum Minimum Maximum A1 171 (6-3/4) 45 (1-49/64) (5-13/16) 454 (17-7/8) 248 (9-3/4) 89 (3-1/2) 1.4 (1/16) 4/78 (3/16) 11-N A2 171 (6-3/4) 45 (1-49/64) 111 (4-3/8) 454 (17-7/8) 248 (9-3/4) 89 (3-1/2) 1.4 (1/16) 4/78 (3/16) 11-J H B1 197 (7-3/4) 45 (1-49/64) (5-13/16) 454 (17-7/8) 248 (9-3/4) 105 (4-9/64) 1.4 (1/16) 4/78 (3/16) 11-H N B2 197 (7-3/4) 45 (1-49/64) 111 (4-3/8) 454 (17-7/8) 248 (9-3/4) 105 (4-9/64) 1.4 (1/16) 4/78 (3/16) 11 41

32 Dimensions Series Enclosure Installation Dimensions Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. A 1 B 1 A 2 B 2 51 [2.01] F C E D Catalog Number 11-C J N Dimension Reference A1 A2 A1 A2 B B C D E F Min. Min. Min. Min. Min. Max. Min. Min. Min. Max. 171 (6/3-4) 171 (6-3/4) 203 (7-63/64) 203 (7-63/64) 45 (1-49/64) 45 (1-49/64) 76 (3) 76 (3) 178 (7) 178 (7) 454 (17-7/8) 454 (17-7/8) 248 (9-3/4) 248 (9-3/4) 89 (3-1/2) 89 (3-1/2) 1.4 (1/16) 1.4 (1/16) 4.78 (3/16) 4/78 (3/16) J H H N B1 B2 197 (7-3/4) 197 (7-3/4) 228 (8-63/64) 228 (8-63/64) 45 (1-49/64) 45 (1-49/64) 76 (3) 76 (3) 178 (7) 178 (7) 454 (17-7/8) 454 (17-7/8) 248 (9-3/4) 248 (9-3/4) 105 (4-9/64) 105 (4-9/64) 1.4 (1/16) 1.4 (1/16) 4.78 (3/16) 4.78 (3/16) 42

33 Dimensions Series 11 Type 3/4/12 - Watertight, Dusttight Sheet Metal Enclosure (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. D Amps Type Dim. Ref. A B C D E F Fused & Non-fused Fused & Non-fused A1, A2 B1, B2 305 (12.00) 305 (12.00) 305 (12.00) 305 (12.00) 173 (6.80) 173 (6.80) 224 (8.81) 224 (8.81) 267 (10.5) 267 (10.5) 267 (10.5) 267 (10.5) Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure (30 & 60A) A F E B D C 11 Amps Type Dim. Ref. A B C D E F Fused & Non-fused Fused & Non-fused A1, A2 B1, B2 305 (12.00) 305 (12.00) 305 (12.00) 305 (12.00) 173 (6.80) 173 (6.80) 224 (8.81) 224 (8.81) 267 (10.5) 267 (10.5) 267 (10.5) 267 (10.5) 43

34 Dimensions Series 11 Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. K 5.5 (15/64) A H D C F B J 32 (1-1/4) G (4)- 8 X 13 SOT MTG. HOES (11/32) (17/32) Amps Type Dim. Ref. A B C D F G H J K 30 & 60 Fused & Non-Fused A1 & A2 B1 & B2 226 (8.92) 267 (10.52) 163 (6.42) 214 (8.43) 278 (10.95) 152 (8.0) 216 (8.50) 305 (12.0) Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure (100A) 6 (0.23) O F F ON 11 D Amps Type Dim. Ref. A B C D E F 100 Fused & Non-fused C1 406 (16.00) 406 (16.00) 224 (8.80) 282 (11.10) 368 (14.5) 368 (14.5) 44

35 Dimensions Series 11 Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure (200 & 400A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. Amps Type Dim. Ref. A B C D E F G H 200 Fused & D1 Non-Fused (16) (24) (8-51/64) (11-5/64) (27-5/64) (25-19/32) (14-1/2) (22-1/2) 400 Fused & F1 Non-Fused (24) (30) (12-51/64) (15-5/64) (33-5/64) (31-15/32) (22-1/2) (28-1/2) Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (100A) K 5 (3/16) A H D C F B J G (4)- 8 X 13 SOT MTG. HOES 32 (1-9/32) (11/32) (17/32) 11 Amps Type Dim. Ref. A B C D F G H J K Fused & C1 Non-Fused (14-31/32) (16-1/4) (8-31/64) (10-49/64) (16-61/64) (12) (14-9/16) (18) (13/64) 44.1

36 Dimensions Series 11 Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (200A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. K 11.5 (29/64) A D C F B J G (4)- 10 DIA. MTG. HOES (13/32) Amps Type Dim. Ref. A B C D F G J K 200 Fused & Non-Fused D1 513 (20-13/64) 625 (24-5/8) 292 (11-31/64) 350 (13-25/32) 648 (25-1/2) 457 (18) 686 (27) 11.5 (29/64) Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (400A) K 10.5 (27/64) A D C F B J 11 57mm (2-1/4") G (4)- 10 DIA. MTG. HOES (13/32") Amps Type Dim. Ref. A B C D F G J K 400 Fused & Non-Fused F1 612 (24 1/8) 775 (30 33/64) 343 (13 31/64) 401 (15 23/32) 796 (31 31/32) 555 (21 7/8) 834 (32 27/32) 10.5 (13/32) 44.2

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! Manual Switching Devices: Control, oad or Fusible Disconnect Switches

More information

Big performance in a small package

Big performance in a small package Series Fusible & Non-fusible Sprecher + Schuh s series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications

More information

Big performance in a small package

Big performance in a small package Series usible & Non-fusible 100 400A Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or usible Which is Best or Your Application? Application Data Typical Control Switch

More information

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊ Series U/CSA Fused Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 200V 240V 460V 600V 125V 250V Catalog Number Price U Class J and CSA HRCI-J Fuses ➋ 30

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Bulletin 194R TABLE OF CONTENTS Bulletin 194R 20 A 400 A Sizes Open or Enclosed Switches d Switch Versions: BS88 DIN CSA HRCII-C CSA HRCI-J UL Class J UL Class CC Non-d Switches Operating Handle Ingress

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38 Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45

More information

LDisconnect Switches. Disconnect Switches

LDisconnect Switches. Disconnect Switches Disconnect Switches Disconnect Switches Series 7 - Motor Disconnect Switches up to 100A...2 Handles & Accessories...10 Series 7 Enclosed Disconnect Switches...14 Technical Information...20 Dimensions...22

More information

194R J S TY N1

194R J S TY N1 Bulletin R IE Fused and Non-Fused Disconnects, & A Product Selection omplete UL/SA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA

More information

L11 Fused and Non-Fused Disconnect Switches (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

L11 Fused and Non-Fused Disconnect Switches (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. Series 11 used and Non-used isconnect Switches (30 & 60A) W A E H imension Approximate imensions in mm (in) Reference H W A ➊ E ➊ A1 108 (4-1/4) 120 (4-3/4) 101 (4) 90 (3-9/16) 105 (4-1/8) 85 (3-11/32)

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IE Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - SA HRII- - SA HRI-MIS - UL lass

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 3150A 30A 3000A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Compact Circuit Protector

Compact Circuit Protector Supersedes February 2019 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP2) 2011/65/EU CCP2 switch up to 100 A 200 A CCP2 switch 400 A CCP2 switch Contents Page 30, 60 and 100 amp switches s and

More information

Compact Circuit Protector

Compact Circuit Protector Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

Rotary Disconnect Switches, Bulletin 194R

Rotary Disconnect Switches, Bulletin 194R ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Rotary Disconnect Switches Bulletin 194R NOTICE: The specification guidelines in this document are intended to aid in the specification

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Section Contents. Disconnect Switches

Section Contents. Disconnect Switches Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses Technical Data 10789 BUSSMANN SERIES Next generation Compact Circuit Protector (cat. no. CCP2) Contents Page 2011/65/EU CCP2 switch and specifications.... 2-3 Catalog numbers.... 4 Conductor information

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 6A 200A 30A 200A Fusible Disconnect SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes April 2014 UL Class CC, CF (CUBEFuse ), Midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-Pole Class CC, Midget, 10x38mm Description & Specifications....

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

Technical data OT16E3 OT160E3 UL & CSA

Technical data OT16E3 OT160E3 UL & CSA Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

ENCLOSED DISCONNECT SWITCHES

ENCLOSED DISCONNECT SWITCHES Ferraz Shawmut Enclosed isconnect es are designed to meet customer s requirements for compact and durable individual disconnecting means. Both fusible and non-fusible versions are available in a variety

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity Cam-Lok connectors are the industry standard Cam-Lok

More information

For many applications

For many applications Series 40 Amp Rugged and dependable 40 amp switches for industrial applications Sprecher + Schuh s rugged rotary cam switches are available for most control and load applications up to 40 amps. A well

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes March 2016 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail 2011/65/EU Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description

More information

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm Supersedes October 2015 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description and

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

FUSIBLE DISCONNECT SWITCHES

FUSIBLE DISCONNECT SWITCHES FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

SECTION SECTION. EATON 2014 Arrow Hart Buyers Guide

SECTION SECTION.     EATON 2014 Arrow Hart Buyers Guide F SECTION SECTION 1 EATON 2014 Arrow Hart Buyers Guide FSECTION Cam-lok Single Pole Connectivity Table of contents Product selector guide F-3 NEMA rating system F-4 F-series F-5 E1010 F-6 E1012 F-7 F-series

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

SECTION. Watertight & Dust-Tight Plugs & Connectors

SECTION. Watertight & Dust-Tight Plugs & Connectors SECTION Watertight & ust-tight Wetguard Product Line Section Contents LIFETIME Wetguard Plugs, Connectors & Straight Blade 2-Pole 3-Wire 2-Pole 3-Wire 3-Pole 4-Wire 3-Pole 3-Wire Non- 4-Pole 4-Wire Non-

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web: -

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web:  - disconnect A 1200A, 600VAC Disconnect Disconnect ABB PowerLine includes seven different amperage sizes from A to 1200A. All ABB fusible are designed to meet customer requirements in terms of high interrupting

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 00A 30A 00A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable

More information

UL 98 Fusible Disconnect Switches

UL 98 Fusible Disconnect Switches UL 98 Fusible isconnect witches ICONNECT WITCHE Mersen s fusible disconnect switches are listed to UL 98 and bear the CE mark conforming to IEC 60947-3. They are service entrance devices capable of fully

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring: SERIES D DISCONNECT SWITCHES 1 Amp 0 Amp 00 & 0 Volt Load Make/Load Break Positive Opening Compact Size Modular Construction Horse Power Rated Custom Versions Featuring: Auto Alignment Shaft Wide Handle

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

SECTION SECTION SECTION EATON 2016 Arrow Hart Buyers Guide

SECTION SECTION SECTION EATON 2016 Arrow Hart Buyers Guide F SECTION SECTION SECTION 1 EATON 2016 Arrow Hart Buyers Guide www.arrowhart.com /arrowhart FSECTION Cam-Lok Single Pole Connectivity Table of contents Product selector guide F-3 NEMA rating system F-4

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application Bussmann Open and Enclosed Rotary Disconnect Switches Exceptional Breadth and Availability f Your Application 2 Visit us on the web at www.cooperbussmann.com/disconnects Table of Contents Compact Circuit

More information

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D) Bulletin 494V Variable Depth Disconnect Switch Installation Instructions (Cat 494V-DS400; -DSX400 - Series D) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.

More information

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth

More information

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions.

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions. Plugs & receptacles Cam-Lok single pole connectivity Cam-Lok Single pole connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok single pole connectivity

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches es Series es... 2 Assemblies... 11 s... 15 Accessories... 25 Technical Information... 26 Dimensions... 31 Series R-Line es... 34 s... 39 Accessories... 40 Technical Information... 41 Dimensions... 42 es

More information

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES FUSIBLE DISCNECT SWITCHES (UL98) GM SERIES Three-pole disconnect switches with fuse holder (UL98) GMF...030 C12 GMFJ 100 C03 GMFJ 400 C03 GMFJ 800 C03 Add-on blocks GMX10 10 GMX3... GMX8 00 GMX8 01 GMX5...

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753 Depth x  Width x 2.375 Height 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit

More information

footprint of traditional fusible switches

footprint of traditional fusible switches Disconnect switches Contents Section page Description Compact Circuit Protector (CCP) disconnect switches Class CC, UL supplemental and IEC 0x38mm (CCP) -3 Class CF CUBEFuse (CCP-CF) 4-5 Compact Circuit

More information

KT4 Manual Motor Starters

KT4 Manual Motor Starters s General Description...F99 Quick Selection Guide...F100 Accessories...F101 Contact Blocks...F101 Adapter Plates...F101 Release Modules...F102 Connecting Modules...F102 Mounting...F103 Enclosures...F103

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information