1 Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 REACTOR SELECTION & PRICING VOLT (3-PHASE) VOLT (50 HZ) USE FOR VOLTS VOLT (3-PHASE) REACTOR VOLT (3-PHASE) REACTOR...7 REACTOR CABINET PRICING GUIDELINES...8 STANDARD NEMA 1 CABINETS...8 OVERSIZED NEMA 1 CABINETS...8 NEMA 3R CABINETS...9 PRODUCT MODIFICATIONS...10 PRODUCT SPECIFICATIONS...14 SERVICE FACTOR...14 MAXIMUM SWITCHING FREQUENCY...14 TEMPERATURE RISE...14 AMBIENT TEMPERATURE...14 FUNDAMENTAL FREQUENCY...14 AGENCY APPROVALS:...15 DIMENSION REFERENCE...17 MECHANICAL DETAILS OPEN REACTORS...18 NEMA1 MECHANICAL DATA...20 RECOMMENDED CONDUIT ENTRY FOR FLOOR MOUNTED...22 ENCLOSURE DIMINSIONS...23 CAB CAB-12C...23 CAB-13V...24 CAB-17V...24 CAB-17C...25 CAB-26C...25 CAB-26D...26 CAB-42C...27 TECHNICAL DATA...28 PB

2 Standard Delivery Schedule OPEN TYPE Standard Open Type (Catalog items) Stock to 1 week (Quantity 1 20) Stock to 2 weeks (Quantity 21-40) Standard Open Type (Catalog Items) Stock to 3 weeks (Quantity 1-4) Stock to 4 weeks (Quantity 5-9) Consult factory for larger quantities Standard Open Type (Non- Catalog Items) 3 4 weeks (Quantity 1-4) 4 5 weeks (Quantity 5-9) Consult factory for larger quantities 1 thru 160 amps 200 thru 750 amps 850 thru 2100 amps Standard Type RL Line / Load Reactors - NEMA 1 Standard NEMA 1 Type (Catalog Items) 2 days to 1-1/2 week (Quantity 1-20) 4 days to 2 weeks (Quantity 21-40) Consult factory for larger quantities Standard NEMA 1 Type (Catalog Items) 1-3 weeks (Quantity 1-4) 7 days to 4 weeks (Quantity 5-9) Consult factory for larger quantities Standard NEMA 1 (Non- Catalog Items) 4 5 weeks (Quantity 1-4) 5-6 weeks (Quantity 5-9) Consult factory for larger quantities 1 thru 160 amps 200 thru 750 amps 850 thru 2100 amps Standard Type RL Line / Load Reactors - NEMA 3R Standard NEMA 3R Type (Catalog Items) 1-3 weeks (Quantity 1-4) 2-4 weeks (Quantity 5-9) Consult factory for larger quantities Standard NEMA 3R Type (Non- Catalog Items) 4 5 weeks (Quantity 1-4) 5-6 weeks (Quantity 5-9) Consult factory for larger quantities 1 thru 750 amps 850 thru 2100 amps PB

3 Standard Delivery Schedule CUSTOM Type RL AC Line / Load Reactors (OPEN and NEMA 1 & 3R Types) Custom type RL AC line / load reactors include those with standard modifications or special ratings. Customized or Special Ratings (Non-Catalog Items) 3 4 weeks (Quantity 1-20) 4 6 weeks (Quantity 21 50) Consult factory for larger quantities 1 thru 160 amps Customized or Special Ratings (Non-Catalog Items) 4 6 weeks (Quantity 1-20) 6 8 weeks (Quantity 21 50) Consult factory for larger quantities 161 thru 750 amps Customized or Special Ratings (Non-Catalog Items) 6 8 weeks (Quantity 1-20) 8 10 weeks (Quantity 21 50) Consult factory for larger quantities. above 750 amps PB

4 Reactor Selection & Pricing Volt (3-phase) 208- OPEN TYPE NEMA 1 TYPE 240V 3 % IMPEDANCE 5 % IMPEDANCE 3 % IMPEDANCE 5 % IMPEDANCE HP Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price 0.25 RL $94 RL $99 RL $175 RL $ RL $82 RL $94 RL $163 RL $ RL $82 RL $94 RL $163 RL $ RL $95 RL $98 RL $176 RL $180 1 RL $95 RL $98 RL $176 RL $ RL $100 RL $112 RL $182 RL $194 2 RL $100 RL $112 RL $182 RL $194 3 RL $118 RL $125 RL $201 RL $208 5 RL $154 RL $158 RL $238 RL $ RL $161 RL $182 RL $295 RL $ RL $182 RL $191 RL $317 RL $ RL $240 RL $252 RL $378 RL $ RL $254 RL $266 RL $393 RL $ RL $295 RL $312 RL $436 RL $ RL $295 RL $312 RL $436 RL $ RL $440 RL $496 RL $588 RL $ RL $440 RL $496 RL $588 RL $ RL $549 RL $613 RL $702 RL $ RL-20001B14 $589 RL-20002B14 $718 RL-20011B14 $744 RL-20012B14 $ RL-25001B14 $667 RL-25002B14 $1,040 RL-25011B14 $826 RL-25012B14 $1, RL-32001B14 $1,051 RL-32002B14 $1,216 RL-32011B14 $1,445 RL-32012B14 $1, RL-40001B14 $1,147 RL-40002B14 $1,708 RL-40011B14 $1,546 RL-40012B14 $2, RL-50001B14 $1,226 RL $1,807 RL-50011B14 $1,628 RL $2, RL $1,496 RL $2,115 RL $2,392 RL $3, RL $2,367 RL $3,059 RL $3,307 RL $4, RL-85001B14 $3,624 RL-85002B14 $4,200 RL-85011B14 $4,627 RL-85012B14 $5, RL B14 $3,500 RL B14 $4,786 RL B14 $5,102 RL B14 $6, RL B14 $4,500 RL B14 $5,055 RL B14 $6,152 RL B14 $6,735 See Line load Reactors for current dimensions and CAD details. For reactor with MOV network installed: 208 Volts Change catalog number from RL-xxxxx to RLA-xxxxx and add $86.00 list price. 240 Volts Change catalog number from RL-xxxxx to RLC-xxxxx and add $86.00 list price. PB

5 400 Volt (50 Hz) use for volts OPEN TYPE NEMA 1 TYPE 400V KW 1.5% Impedance 3% Impedance 5% Impedance 1.5% Impedance 3% Impedance 5% Impedance Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price 0.18 RL $81 RL $85 RL $91 RL $162 RL $166 RL $ RL $81 RL $85 RL $91 RL $162 RL $166 RL $ RL $94 RL $99 RL $113 RL $175 RL $181 RL $ RL $82 RL $99 RL $113 RL $163 RL $181 RL $ RL $82 RL $94 RL $99 RL $163 RL $175 RL $ RL $95 RL $102 RL $117 RL $176 RL $184 RL $ RL $95 RL $98 RL $102 RL $176 RL $180 RL $ RL $112 RL $153 RL $157 RL $194 RL $237 RL $ RL $100 RL $112 RL $153 RL $182 RL $194 RL $ RL $118 RL $125 RL $180 RL $201 RL $208 RL $ RL $154 RL $158 RL $209 RL $238 RL $243 RL $ RL $161 RL $182 RL $215 RL $295 RL $317 RL $ RL $182 RL $191 RL $285 RL $317 RL $327 RL $ RL $240 RL $252 RL $334 RL $378 RL $391 RL $ RL $240 RL $252 RL $334 RL $378 RL $391 RL $ RL $254 RL $266 RL $338 RL $393 RL $405 RL $ RL $295 RL $312 RL $549 RL $436 RL $454 RL $ RL $397 RL $436 RL $641 RL $543 RL $584 RL $ RL $440 RL $496 RL $655 RL $588 RL $647 RL $ RL $549 RL $613 RL $737 RL $702 RL $770 RL $ RL-20001B14 $589 RL-20002B14 $718 RL-20003B14 $900 RL-20011B14 $744 RL-20012B14 $880 RL-20013B14 $1, RL-25001B14 $667 RL-25002B14 $1,040 RL-25003B14 $1,595 RL-25011B14 $826 RL-25012B14 $1,433 RL-25013B14 $2, RL-32001B14 $1,051 RL-32002B14 $1,216 RL-32003B14 $1,705 RL-32011B14 $1,445 RL-32012B14 $1,618 RL-32013B14 $2, RL-40001B14 $1,147 RL-40002B14 $1,708 RL-40003B14 $2,091 RL-40011B14 $1,546 RL-40012B14 $2,135 RL-40013B14 $2, RL-40001B14 $1,147 RL-40002B14 $1,708 RL-40003B14 $2,091 RL-40011B14 $1,546 RL-40012B14 $2,135 RL-40013B14 $2, RL-50001B14 $1,226 RL $1,807 RL $2,427 RL-50011B14 $1,628 RL $2,719 RL $3, RL $1,496 RL $2,115 RL $3,357 RL $2,392 RL $3,042 RL $4, RL $2,367 RL $3,059 RL $4,320 RL $3,307 RL $4,033 RL $5, RL-90001B14 $3,776 RL-90002B14 $4,148 RL-90003B14 $5,645 RL-90011B14 $5,392 RL-90012B14 $5,783 RL-90013B14 $7, RL B14 $3,500 RL B14 $4,786 RL B14 $6,307 RL B14 $5,102 RL B14 $6,453 RL B14 $8, RL B14 $4,500 RL B14 $5,055 RL B14 $6,679 RL B14 $6,152 RL B14 $6,735 RL B14 $8, RL $5,632 RL $6,576 RL $7,334 RL $7,824 RL $8,814 RL $9, RL * -- RL * -- RL * -- RL * -- RL * -- RL * RL * -- RL * -- RL * -- RL * -- RL * -- RL * RL * -- RL * -- RL * -- RL * -- RL * -- RL * RL * -- RL * -- RL * -- RL * -- RL * -- RL * * -- Consult Factory for Price See Line load Reactors for current dimensions and CAD details. For reactor with MOV network installed: Change catalog number from RL-xxxxx to RLE-xxxxx and add $86.00 to the list price. PB

6 480 Volt (3-phase) Reactor MTE AC Line / Load Reactors OPEN TYPE NEMA 1 TYPE 480V HP 1.5% Impedance 3 % IMPEDANCE 5 % IMPEDANCE 1.5% Impedance 3 % Impedance 5 % Impedance Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price 0.25 RL $81 RL $85 RL $91 RL $162 RL $166 RL $ RL $81 RL $85 RL $91 RL $162 RL $166 RL $ RL $81 RL $81 RL $85 RL $162 RL $162 RL $ RL $82 RL $94 RL $99 RL $163 RL $175 RL $181 1 RL $82 RL $94 RL $99 RL $163 RL $175 RL $ RL $82 RL $94 RL $99 RL $163 RL $175 RL $181 2 RL $95 RL $98 RL $102 RL $176 RL $180 RL $184 3 RL $112 RL $153 RL $157 RL $194 RL $237 RL $242 5 RL $100 RL $112 RL $153 RL $182 RL $194 RL $ RL $118 RL $125 RL $180 RL $201 RL $208 RL $ RL $154 RL $158 RL $209 RL $238 RL $243 RL $ RL $161 RL $182 RL $215 RL $295 RL $317 RL $ RL $182 RL $191 RL $285 RL $317 RL $327 RL $ RL $182 RL $191 RL $285 RL $317 RL $327 RL $ RL $240 RL $252 RL $334 RL $378 RL $391 RL $ RL $254 RL $266 RL $338 RL $393 RL $405 RL $ RL $295 RL $312 RL $549 RL $436 RL $454 RL $ RL $295 RL $312 RL $549 RL $436 RL $454 RL $ RL $397 RL $436 RL $641 RL $543 RL $584 RL $ RL $440 RL $496 RL $655 RL $588 RL $647 RL $ RL $549 RL $613 RL $737 RL $702 RL $770 RL $ RL-20001B14 $589 RL-20002B14 $718 RL-20003B14 $900 RL-20011B14 $744 RL-20012B14 $880 RL-20013B14 $1, RL-25001B14 $667 RL-25002B14 $1,040 RL-25003B14 $1,595 RL-25011B14 $826 RL-25012B14 $1,433 RL-25013B14 $2, RL-32001B14 $1,051 RL-32002B14 $1,216 RL-32003B14 $1,705 RL-32011B14 $1,445 RL-32012B14 $1,618 RL-32013B14 $2, RL-40001B14 $1,147 RL-40002B14 $1,708 RL-40003B14 $2,091 RL-40011B14 $1,546 RL-40012B14 $2,135 RL-40013B14 $2, RL-50001B14 $1,226 RL $1,807 RL $2,427 RL-50011B14 $1,628 RL $2,719 RL $3, RL-50001B14 $1,226 RL $1,807 RL $2,427 RL-50011B14 $1,628 RL $2,719 RL $3, RL $1,496 RL $2,115 RL $3,357 RL $2,392 RL $3,042 RL $4, RL $2,367 RL $3,059 RL $4,320 RL $3,307 RL $4,033 RL $5, RL-85001B14 $3,624 RL-85002B14 $4,200 RL-85003B14 $4,957 RL-85011B14 $4,627 RL-85012B14 $5,231 RL-85013B14 $6, RL B14 $3,500 RL B14 $4,786 RL B14 $6,307 RL B14 $5,102 RL B14 $6,453 RL B14 $8, RL B14 $4,500 RL B14 $5,055 RL B14 $6,679 RL B14 $6,152 RL B14 $6,735 RL B14 $8, RL B14 $4,500 RL B14 $5,055 RL B14 $6,679 RL B14 $6,152 RL B14 $6,735 RL B14 $8, RL $5,632 RL $6,576 RL $7,334 RL $7,824 RL $8,814 RL $9, RL * -- RL * -- RL * -- RL * -- RL * -- RL * RL * -- RL * -- RL * -- RL * -- RL * -- RL * RL * -- RL * -- RL * -- RL * -- RL * -- RL * RL * -- RL * -- RL * -- RL * -- RL * -- RL * RL * -- RL * -- RL * -- RL * -- RL * -- RL * RL * -- RL * -- RL * -- RL * -- RL * -- RL * RL * -- RL * -- RL * -- RL * -- RL * -- RL * * -- Consult Factory for Price See Line load Reactors for current dimensions and CAD details. For reactor with MOV network installed: Change catalog number from RL-xxxxx to RLG-xxxxx then add $86.00 list price. PB

7 600 Volt (3-phase) Reactor MTE AC Line / Load Reactors OPEN TYPE NEMA 1 TYPE 600v HP 1.5% Impedance 3% Impedance 5% Impedance 1.5% Impedance 3% Impedance 5% Impedance Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price 0.25 RL $85 RL $91 RL $106 RL $166 RL $172 RL $ RL $85 RL $91 RL $106 RL $166 RL $172 RL $ RL $81 RL $85 RL $91 RL $162 RL $166 RL $ RL $94 RL $99 RL $113 RL $175 RL $181 RL $195 1 RL $94 RL $99 RL $113 RL $175 RL $181 RL $ RL $94 RL $99 RL $113 RL $175 RL $181 RL $195 2 RL $98 RL $102 RL $117 RL $180 RL $184 RL $200 3 RL $98 RL $102 RL $117 RL $180 RL $184 RL $200 5 RL $112 RL $153 RL $157 RL $194 RL $237 RL $ RL $118 RL $125 RL $180 RL $201 RL $208 RL $ RL $118 RL $125 RL $180 RL $201 RL $208 RL $ RL $154 RL $158 RL $209 RL $238 RL $243 RL $ RL $161 RL $182 RL $215 RL $295 RL $317 RL $ RL $161 RL $182 RL $215 RL $295 RL $317 RL $ RL $182 RL $191 RL $285 RL $317 RL $327 RL $ RL $240 RL $252 RL $334 RL $378 RL $391 RL $ RL $254 RL $266 RL $338 RL $393 RL $405 RL $ RL $295 RL $312 RL $549 RL $436 RL $454 RL $ RL $295 RL $312 RL $549 RL $436 RL $454 RL $ RL $397 RL $436 RL $641 RL $543 RL $584 RL $ RL $440 RL $496 RL $655 RL $588 RL $647 RL $ RL $549 RL $613 RL $737 RL $702 RL $770 RL $ RL-20001B14 $589 RL-20002B14 $718 RL-20003B14 $900 RL-20011B14 $744 RL-20012B14 $880 RL-20013B14 $1, RL-25001B14 $667 RL-25002B14 $1,040 RL-25003B14 $1,595 RL-25011B14 $826 RL-25012B14 $1,433 RL-25013B14 $2, RL-32001B14 $1,051 RL-32002B14 $1,216 RL-32003B14 $1,705 RL-32011B14 $1,445 RL-32012B14 $1,618 RL-32013B14 $2, RL-40001B14 $1,147 RL-40002B14 $1,708 RL-40003B14 $2,091 RL-40011B14 $1,546 RL-40012B14 $2,135 RL-40013B14 $2, RL-40001B14 $1,147 RL-40002B14 $1,708 RL-40003B14 $2,091 RL-40011B14 $1,546 RL-40012B14 $2,135 RL-40013B14 $2, RL-50001B14 $1,226 RL $1,807 RL $2,427 RL-50011B14 $1,628 RL $2,719 RL $3, RL $1,496 RL $2,115 RL $3,357 RL $2,392 RL $3,042 RL $4, RL $2,367 RL $3,059 RL $4,320 RL $3,307 RL $4,033 RL $5, RL-85001B14 $3,624 RL-85002B14 $4,200 RL-85003B14 $4,957 RL-85011B14 $4,627 RL-85012B14 $5,231 RL-85013B14 $6, RL-90001B14 $3,776 RL-90002B14 $4,148 RL-90003B14 $5,645 RL-90011B14 $5,392 RL-90012B14 $5,783 RL-90013B14 $7, RL B14 $3,500 RL B14 $4,786 RL B14 $6,307 RL B14 $5,102 RL B14 $6,453 RL B14 $8, RL B14 $4,500 RL B14 $5,055 RL B14 $6,679 RL B14 $6,152 RL B14 $6,735 RL B14 $8, RL B14 $4,500 RL B14 $5,055 RL B14 $6,679 RL B14 $6,152 RL B14 $6,735 RL B14 $8, RL $5,632 RL $6,576 RL $7,334 RL $7,824 RL $8,814 RL $9, RL $5,632 RL $6,576 RL $7,334 RL $7,824 RL $8,814 RL $9, RL * -- RL * -- RL * -- RL * -- RL * -- RL * * -- Consult Factory for Price See Line load Reactors for current dimensions and CAD details. For reactor with MOV network installed: Change catalog number from RL-xxxxx to RLJ-xxxxx then add $86.00 list price. PB

8 REACTOR CABINET PRICING GUIDELINES STANDARD NEMA 1 CABINETS Open Reactor Part Numbers Cabinet Cat. No. List Price For RL thru RL CAB-8 $73 For RL thru RL-25001B14 CAB-13V $120 For RL-25002B14 thru RL-50001B14 CAB-17V $325 For RL thru RL-85002B14 CAB-26C $782 For RL-85003B14 thru RL B14 CAB-26D $1359 For RL thru RL CAB-42C $1819 Oversized NEMA 1 Cabinets For type RL AC Line / Load Reactors with open reactor part numbers from RL through RL B14 mounted in oversized enclosures change catalog number from RL-xxx0x to RL-xxx2x and calculate the list price according to the following formula: List Price = 1.05( List price of open reactor +List price of enclosure from table below). For type RL AC Line / Load Reactors with open reactor part numbers from RL-25002B14 through RL B14 mounted in oversized enclosures change catalog number from RL-xxx0x to RL-xxx4x and calculate the list price according to the following formula: List Price = 1.05( List price of open reactor +List price of enclosure from table below). OVERSIZED NEMA 1 CABINETS Open Reactor Part Numbers Cabinet Cat. No. List Price For RL thru RL CAB-13V $120 For RL thru RL-25001B14 CAB-17V $325 For RL-25002B14 thru RL-50001B14 CAB-26C $782 For RL thru RL-85002B14 CAB-26D $1359 For RL-85003B14 thru RL B14 CAB-42C $1819 PB

9 NEMA 3R CABINETS MTE AC Line / Load Reactors For type RL AC Line / Load Reactors with NEMA 1 enclosed reactors mounted in NEMA 3R enclosures change catalog number from RL-xxx1x to RL-xxx3x and calculate the list price according to the following formula: List Price = List Price of NEMA 1 Reactor + List Price NEMA 3R Adder from table below). NEMA 3R CABINETS NEMA 1 Enclosed Reactor Part Numbers Cabinet Cat. No. List Price Adder For RL thru RL CAB-12C $511 For RL thru RL-25011B14 CAB-17C $555 For RL-25012B14 thru RL-50011B14 CAB-17C $350 For RL thru RL-85012B14 CAB-26C $147 For RL-85013B14 thru RL B14 CAB-26D $206 For RL thru RL CAB-42C $211 Spare Parts For standard type RL AC Line / Load Reactors Description Part No. List Price To adds SLU 225 box lugs on B14 Lug Kit 003 $190 To adds XT 500 box lugs on B14 Lug Kit 002 $190 Terminal Blocks Description Part No. List Price For RL thru RL $8. For RL thru RL $17. For RL thru RL TERMBLK-013 $23. PB

10 PRODUCT MODIFICATIONS Description of Modification Add Suffix List Price Set-up Networks: Add MOV transient protector to reactor 208 volts RLA- $86. $0 240 volts RLC- $86. $ volts RLE- $86. $0 480 volts RLG- $86. $0 600 volts RLJ- $86. $0 Temperature Switches: Add 3-NC over temp switches w/ 6 point terminal block.t $100. $72. Add 1 thermocouple per coil (customer supplied).t1 $80. $72. Add 3-NC over temp switches with leads.t2 $85. $72. Add 1-NC over temp switch w/ 2 point terminal block.t5 $50. $72. Add 3-NO over temp switches w/6 point terminal block..t6 $100. $72. Add thermocouple to center coil only (customer supplied).t7 $40. $72. Add two thermocouples (customer supplied) T8 $70. $72. PB

11 PRODUCT MODIFICATIONS Description of Modification Add Suffix List Price Set-up Terminations: Substitute Box Lug for terminal block...b $60. $72. Substitute Tab terminal w/clearance hole (see next page)...b1 $36. $72. RL thru RL Substitute flexible leads (18 inches typical) RL thru RL B5 $30. $72. RL thru RL B5 $48. $72. RL thru RL B5 $96. $72. Substitute next larger Box Lug RL thru RL B6 $62. $72. RL thru RL B6 $84. $72. Substitute 35 amp terminal block for smaller 20 amp terminal block.b7 $23. $72. Rotate terminal block 90 degrees (see next page) B8 $12. $72. Add 3-point control circuit terminal block RL thru RL B9 $30. $72. RL thru RL B11 $72. $72. Sub. accessory wiring t/b RL thru RL B10 $28. $72. Substitute front facing tab (flag) terminal (see next page)....b14 $36. $72. Substitute next larger terminal block (RL thru RL-03502)..B18 $36. $72. SLU Encorporate SLU Lugs to terminal Tabs on B14 reactors listed below: Note: These terminals are shipped loose ready to be bolted to the present B14 copper tab terminations. Adder RL None $190 RL None $190 RL None $190 RL None $190 RL None $190 RL None $190 RL None $190 RL None $190 RL None $190 RL None $190 RL None $190 RL None $190 To incorporate SLU option drop B14 and add above amounts to the base list price. Use part numbers as shown. PB

12 PRODUCT MODIFICATIONS continued: B1 Terminal Modification B14 Terminal Modification B8 Terminal Modification SLU Lug Option Wire range: Wire range: mcm PB

13 SLU Lug Options cont. SLU 225 shown on 200 amp Reactor XT 500 shown on 250 amp Reactor PB

14 PRODUCT SPECIFICATIONS Standard Type RL AC Line / Load Reactors Standard impedance values Impedance basis Service Factor (Continuous) Reactors rated 1 to 750 Amps Reactors rated above 750 Amps Overload Rating Maximum system voltage Maximum switching frequency 1-1/2%, 2, 3%, 4%, 5% available Reactor fundamental current rating 150% of fundamental rating 125% of fundamental rating minimum Note: Select reactor based on fundamental current rating 200% of fundamental for 30 minutes 300% of fundamental for 1 minute 600 Volts ( units with terminal blocks) 690 Volts (units with box lugs or tab terminals) 20 KHz Insulation system Class N (200 C) Temperature rise Open or enclosed reactors Ambient temperature Open or enclosed reactors Altitude (maximum) Fundamental frequency Line or Load 135 C (average) 45 C (maximum) 1000 meters 50/60 Hz Approvals: CE, UL-508, CSA C22.2 Inductance curve (typical) 100% at 100% current 100% at 150% current 50% at 350% current (minimum) Inductance tolerance +/- 10% Impregnation: Dielectric Strength dv/dt Protection Protection: High Bond Strength Solvent less Epoxy, 200 C UL94HB recognized 3000 volts rms (4243 volts peak) Meets NEMA MG-1, part 31 (same as inverter duty motors) Open reactors with terminal blocks through 45 amps meet IP20 PB

15 AGENCY APPROVALS: PRODUCT SPECIFICATIONS (cont d) UL-508, UL-508, File E Component Listed (1 amp 2400 amps) File E UL Listed NEMA 1 units (1 amp 2400 amps) Note: Short Circuit rating not required under Exception No.1 of UL508A SB4.2.1 effective 4/25/06 CSA C22.2, Class N, 200 C, CE Marked File LR CSA Certified (1 amp 2400 amps) File E66214, Type , UL Recognized Insulation System MATERIAL: Core Steel: Electrical grade silicon steel Windings: High dielectric withstand solid copper conductor (220 C) Enclosures: Sheet steel in accordance with UL and CSA requirements. Painted ANSI-61 Grey Brackets: ASTM structural steel or structural aluminum Terminations: 1 45 amps - Finger safe terminal block amps - Solid copper box lugs (Tab terminals are optional) amps - Copper tab terminals Sheet Insulation: DuPont Nomex 410 (220 C) Epoxy: Ripley Resin Type (220 C) CONSTRUCTION: CORE: WINDINGS: ASSEMBLY: COLOR: TESTING: Electrical grade silicon steel magnetic laminations. Meet 3000 volts rms dielectric strength (coil to coil and coil- to core). Windings are assembled onto EI laminations, secured in place and epoxy impregnated for minimum noise and maximum structural rigidity. Royal Blue Electronic Turns Count (Zero Tolerance) Inductance Hi-Pot 3000 Volts rms (5656 volts peak) Mechanical Inspection PB

16 PRODUCT SPECIFICATIONS (cont d) AUDIBLE NOISE: Guard-AC Line/Load Reactors offer low noise operation. Core and coil construction, flux density control, harmonic compensation as well as our epoxy impregnation process assure minimal audible noise radiation. Although our reactors are typically quiet, waveforms vary by drive type and application and therefore reactor audible noise may vary by application. Noise levels may be affected by type of motor and motor conductor as well as motor conductor length. Typical audible noise levels for units selected from our catalog by HP rating are: 2 thru 12 amps 55 dba 18 thru 100 amps 65 dba 130 thru 400 amps 70 dba 500 thru 1200 amps 75 dba Service Factor: Guard-AC reactors are compensated for the additional currents and high frequencies caused by the presence of harmonics. The reactor fundamental current rating indicates the typical full load motor current and is also the basis of impedance rating. Standard reactors rated 1 amps thru 750 amps offer a full 1.5 service factor rating which allows them to carry overload current up to 150% of their fundamental rating when applied as an input line reactor. Since the nameplate ratings of motor drives (ASD) varies widely by manufacturer, this helps to assure that the reactor maximum current rating is compatible with the nameplate current rating on the ASD. The service factor rating compensates for ASD manufacturer variances in motor drive current ratings and for harmonic currents. Nominal inductance is assured all the way up to the service factor current rating. PWM / IGBT PROTECTION: Guard-AC reactors are protected against the high peak voltage and fast rise time voltage pulses associated with PWM waveforms. The dielectric strength is 4000 volts rms and Guard-AC reactors meet the ratings of an inverter duty motor (NEMA MG-1, part 31). For convenience, they can be located either at the motor or at the drive. HARMONIC ATTENUATION: Our unique harmonic compensation assures maximum circuit inductance in the presence of complex waveforms and can be relied upon to minimize input total harmonic current distortion (THID). Additionally it offers superior absorption of transient voltage spikes. Our standard reactors will typically reduce 6-pulse rectifier input current harmonics to the following levels at full load operating conditions: 3% reactor alone 45% or less THID 5% reactor alone 35% or less THID 3% AC reactor + 3% DC link choke 33% or less THID 5% AC reactor + 3% DC link choke 28% or less THID (DC link choke inductance is equivalent ac impedance). Note: to attain IEEE 519 compliance up to THID 5% use MTE Matrix Harmonic filters. PB

17 Dimension Reference Open Type Visit the MTE web for reactor detail drawings Dimensions A, B, C show overall spacing allowances Use dimension D and E for mounting pattern See Mechanical Details Table for dimensional data PB

18 Mechanical Details Open Reactors MTE A Width B Height C Depth D E Weight Mass Cat. No. Inches mm Inches mm Inches mm Inches mm Inches mm Lbs Kg RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL-20001B RL-20002B RL-20003B RL-25001B RL-25002B RL-25003B See Line load Reactors for current dimensions and CAD details PB

19 Mechanical Data Open Type Cont. MTE A Width B Height C Depth D E Weight Mass Cat. No. Inches mm Inches mm Inches mm Inches mm Inches mm Lbs Kg RL-32001B RL-32002B RL-32003B RL-40001B RL-40002B RL-40003B RL RL RL RL RL RL RL RL RL RL-85001B RL-85002B RL-85003B RL-90001B RL-90002B RL-90003B RL B RL B RL B RL B RL B RL B RL RL RL RL RL RL RL RL RL RL RL RL See Line load Reactors for current dimensions and CAD details PB

20 NEMA1 Mechanical Data Catalog Cabinet Weight Mass Number Number Lbs Kg RL RL RL RL RL RL RL RL CAB-8 RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL CAB-13V RL RL RL RL RL RL RL RL RL RL RL RL PB

21 MECHANICAL DATA NEMA 1 Cont. Catalog Cabinet Weight Mass Number Number Lbs Kg RL-20011B RL-20012B14 CAB-13V RL-20013B RL-25011B RL-25012B RL-25013B RL-32011B RL-32012B CAB-17V RL-32013B RL-40011B RL-40012B RL-40013B RL-50011B RL RL RL RL RL CAB-26C RL RL RL RL-85011B RL-85012B RL-85013B RL-90011B RL-90012B RL-90013B RL B CAB-26D RL B RL B RL B RL B RL B RL RL RL RL RL RL CAB-42C RL RL RL RL RL RL PB

22 Recommended conduit entry for Floor Mounted NEMA 1 enclosed reactors. Note: The entry locations shown above are for reference only. The electrician installing the reactor guided by the local codes determines the final entry wiring. MTE does not pre- punch entry holes or provide wiring hardware with the standard product. PB

23 ENCLOSURE DIMINSIONS CAB-8 CAB-12C PB

24 ENCLOSURE DIMENSIONS CAB-13V CAB-17V PB

25 ENCLOSURE DIMENSIONS Cab-17C CAB-26C PB

26 ENCLOSURE DIMENSIONS CAB-26D PB

27 ENCLOSURE DIMENSIONS CAB-42C PB

28 TECHNICAL DATA Catalog Watts Loss Wire Range Terminal Torque Ind. Fund Max Number (watts) (AWG) (in lbs) mh Amps Amps RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL RL (45) & 2-0(50) RL (45) & 2-0(50) RL (45) & 2-0(50) RL (45) & 2-0(50) RL (45) & 2-0(50) RL (45) & 2-0(50) RL (45) & 2-0(50) RL (45) & 2-0(50) RL (45) & 2-0(50) RL RL RL RL RL RL PB

29 TECHNICAL DATA (cont d) Catalog Watts Loss Wire Range Terminal Torque Ind Fund Max Number (watts) (AWG) (in lbs) mh Amps Amps RL-20001B Copper Tab Not Applicable RL-20002B Copper Tab Not Applicable RL-20003B Copper Tab Not Applicable RL-25001B Copper Tab Not Applicable RL-25002B Copper Tab Not Applicable RL-25003B Copper Tab Not Applicable RL-32001B Copper Tab Not Applicable RL-32002B Copper Tab Not Applicable RL-32003B Copper Tab Not Applicable RL-40001B Copper Tab Not Applicable RL-40002B Copper Tab Not Applicable RL-40003B Copper Tab Not Applicable RL-50001B Copper Tab Not Applicable RL Copper Tab Not Applicable RL Copper Tab Not Applicable RL Copper Tab Not Applicable RL Copper Tab Not Applicable RL Copper Tab Not Applicable RL Copper Tab Not Applicable RL Copper Tab Not Applicable RL Copper Tab Not Applicable RL-85001B Copper tab Not Applicable RL-85002B Copper tab Not Applicable RL-85003B Copper tab Not Applicable RL-90001B Copper tab Not Applicable RL-90002B Copper tab Not Applicable RL-90003B Copper tab Not Applicable RL B Copper tab Not Applicable RL B Copper tab Not Applicable RL B Copper tab Not Applicable RL B Copper tab Not Applicable RL B Copper tab Not Applicable RL B Copper tab Not Applicable RL Copper tab Not Applicable RL Copper tab Not Applicable RL Copper tab Not Applicable RL Copper tab Not Applicable RL Copper tab Not Applicable RL Copper tab Not Applicable Contact factory for higher ratings. PB

30 ISO AC Line / Load Reactors PB-1100 Responsibility: Corporate Approved by: Karl Hink File Location: J:\Public\Controlled Documents\Sales\Price Book Revision Date Revision History New document written by Karl Hink replaces existing web document PB /18/04 dated 1/1/ /24/04 Revised by Karl Hink. Revised by Hank Nechvatal replaced conduit entry drawing on page 15 with jpeg /22/04 format, so it doesn t come out dark when made into a pdf file. By WRW : RL CAB prices reflect higher steel costs ;change to V cabs, update prices 003 3/02/05 for current FC; replace SLU with B1 on AMP; SLU is option /03/05 Revised by Wayne Walcott UL 508 agency approval data, N class insulation /06/05 Rev. by Wayne Walcott RL-60003, RL-60013, RL-85003B14, RL prices /20/06 Rev by WRW adds PE reactors 80 to 750 amps; B14 standard 200 to 400 amp /07/06 Rev by WRW updated NEMA1 weights page 20 & /12/ /28/07 Rev by WRW added RL-8500(1-3)B14 & Rl-9001(2-3)B14 revised selection & mechanical tables; New selection replaces overload V.75 HP,40 HP;480V 3HP;600 V 7.5 Hp fix Cab 17C drawing ECN 5460 Rev by WRW adds wooden crate costs to RL-25003B14, RL-32003B14, RL-40002B14, RL-40003B14, RL RL-75003, replace cab-30b with Cab 26D and adjust costs, RL-75012B14 to RLl-85012B14 moved to CAB 26C, 850 amp to 1200 amp changed to RL-85001B14 to RL B14. Ref ECN 5512 PB

AC Line / Load Reactors

AC Line / Load Reactors AC Line / Load Reactors Table of Contents Delivery / Lead Time.PB03-1100 -2 Selection & Pricing PB03-1100 -4 Replacement Parts..PB03-1100-8 Product Modifications / Options..PB03-1100 -9 Product Specifications..PB03-1100

More information

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation M T E C o r p o r a t i o n MTE Series RL Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL. 060227 2006 MTE Corporation Important User Information NOTICE MTE Series RL Line/Load Reactors are components

More information

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation M T E C o r p o r a t i o n MTE Series RL Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL. 050516 2002 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RL Line/Load Reactors are components

More information

Series A DC Link Chokes

Series A DC Link Chokes Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 INTRODUCTION...3 LIST PRICE / CROSS REFERENCE...4 SELECTION & LIST PRICE...5 208 VOLTS (60 HZ)...5 240 VOLTS (60 HZ)...6 400 VOLTS

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090529 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW Line/Load Reactors are components designed to improve the

More information

1321 Power Conditioning Products

1321 Power Conditioning Products Technical Data 1321 Power Conditioning Products Don t Ignore the Cost of Power Line Disturbance Topic Page Product Overview 2 1321-3R and 3RA Series Line Reactors 3 1321 Reflective Wave Reduction (RWR)

More information

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS HPS CENTURION R REACTORS AND RC DV/DT FILTERS Single and Three Phase Why Choose a Line Reactor?... 98 Construction Features... 100 HPS Centurion R Reactors Specifications... 101 Part Number Guide... 102

More information

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 080920 2008 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter is designed for harmonic mitigation

More information

MOTOR PROTECTION Sine Wave 2-8 khz Series A Filter Table of Contents

MOTOR PROTECTION Sine Wave 2-8 khz Series A Filter Table of Contents MOTOR PROTECTION Table of Contents Application & Selection Guides TR-1701-2 Selection: 440-480 VAC TR-1701-3 550-600 VAC TR-1701-4 Options Selection: Product Specification Model Number Code System Mechanical

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS KLR Series Three Phase Reactors PRODUCT SPECIFICATIONS Lifetime Warranty Performance Guarantee K-Rated, UL/ULC-Recognized; CSA-Certified 3 Phase, 600V Class Gapped Iron Core Inductor All Copper Windings

More information

RLW. Reactors. mtecorp.com. Smaller, lighter protection. Power quality. Solved.

RLW. Reactors. mtecorp.com. Smaller, lighter protection. Power quality. Solved. mtecorp.com RLW Reactors State-of the-art solution for absorbing everyday power line disturbances Smaller, lighter protection. Proven performance in the field Reliable and economical Compact and lightweight

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

MATRIX FILTER USER MANUAL. SERIES D 400 Volts, 50HZ PART NO. INSTR 025 REL REV MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 400 Volts, 50HZ PART NO. INSTR 025 REL REV MTE Corporation MATRIX FILTER SERIES D 400 Volts, 50HZ USER MANUAL PART NO. INSTR 025 REL. 110624 REV. 006 2011 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter is designed for harmonic

More information

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 120628 REV. 007 2012 MTE Corporation Matrix Series D User s Manual 600VAC IMPORTANT USER INFORMATION NOTICE The MTE Corporation

More information

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation MATRIX FILTER SERIES D 480 Volts, 60HZ USER MANUAL PART NO. INSTR 024 REL. 120628 REV. 012 2012 MTE Corporation Matrix Series D User s Manual 480VAC IMPORTANT USER INFORMATION NOTICE The MTE Corporation

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 040709 2003 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

HPS Centurion R Reactor. Why Choose a Reactor? Connection Diagram

HPS Centurion R Reactor. Why Choose a Reactor? Connection Diagram HPS Centurion R Reactor The new HPS Centurion R reactor provides a unique blend of improved performance and reliability while reducing the product footprint. HPS Centurion R reactors deliver protection

More information

RLW Reactors. Product Selector. Smaller. Lighter. mtecorp.com. Proven performance in the field. Reliable and economical. Compact and light-weight

RLW Reactors. Product Selector. Smaller. Lighter. mtecorp.com. Proven performance in the field. Reliable and economical. Compact and light-weight mtecorp.com RLW Product Selector Smaller. Lighter. Proven performance in the field Reliable and economical Compact and light-weight Ideal for OEMs, integrators and panel builders Our RLW Line/Load are

More information

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number) POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 480 Volts, 60Hz April 15, 2010: updated capacitor UL File number) Page 1 of 14 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Advantage

More information

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of

More information

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation

More information

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed

More information

dv Sentry Product Selector dv/dt Filters mtecorp.com Ln Line Side Ld Load Side The future is here. Power quality. Solved.

dv Sentry Product Selector dv/dt Filters mtecorp.com Ln Line Side Ld Load Side The future is here. Power quality. Solved. mtecorp.com dv/dt Filters dv Sentry Product Selector The future is here. The dv Sentry is like nothing you ve seen before. Our latest patented* technological innovation has made the dv Sentry the revolutionary

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6 I. PART 1 GENERAL 1. SCOPE A. NEMA Premium copper-wound ultra low loss isolation transformer with a higher efficiency than that required by NEMA Std. TP-1. Optimized for energy efficiency over a wide load

More information

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL Design Standard Detailed specifications follow. PART 1 - GENERAL 1.01 SCOPE This design guidelines contained herein include the requirements of electric motors utilized for electric motor driven systems

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the

More information

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

High Frequency SineWave Guardian TM

High Frequency SineWave Guardian TM High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation

More information

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System

More information

Modifiable TITAN Horizontal Motors Accessories and Modifications

Modifiable TITAN Horizontal Motors Accessories and Modifications 36. Rotor, Standard And Optional Construction Standard rotor construction of 449, 5000 and 5800 frame TITAN products is typically die-cast aluminum. 720 RPM and slower is typically fabricated aluminum.

More information

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible

More information

Description Reactor, Open; 460 V 3 Phase; Power Rating 30 HP; Impedance 3 Percent; Inductance 0.7 Millihenry; Baldor Brand; Current Rating 45 Ampere

Description Reactor, Open; 460 V 3 Phase; Power Rating 30 HP; Impedance 3 Percent; Inductance 0.7 Millihenry; Baldor Brand; Current Rating 45 Ampere LRAC04502 Line Reactor Baldor Electric CO. Catalog Number LRAC04502 Manufacturer Baldor Electric CO. Description Reactor, Open; 460 V 3 Phase; Power Rating 30 HP; Impedance 3 Percent; Inductance 0.7 Millihenry;

More information

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting

More information

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY TYPE AEHE, AEHH8N, AEHH8NCF, AEUH8NDC Effective 05-01-13 Supercedes 08-01-11 APPLICATIONS: Fans & Blowers Compressor Any Severe Duty/ Petro-Chem/ Pumps Mixers Pulp

More information

2 SLR Series Line Reactors... 50

2 SLR Series Line Reactors... 50 Drive Isolation & Protection Line Reactors Drive Isolation Transformers 2 SLR Series Line Reactors... 50 Drive Isolation Transformers... 51 Selection Table and Design Styles... 52 Electrical Connections...

More information

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base THREE PHASE MOTORS DRIP-PROOF RPM 60 HP Hz 1/4 1725 1725 S56 100027 $246 A 16 208-230/460 1.4 58.0 9.24 1/3 3450 48 101447 251 A 14 208-230/460 1.4 68.0 9.00 1725 48 100446 266 A 17 208-230/460 1.6 64.3

More information

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state

More information

Use the following standards for system design and performance requirements.

Use the following standards for system design and performance requirements. Design The Electrical Motor Design Guidelines contains design criteria and specifications used in the procurement of electrical 3-phase AC induction motors. Table of Contents 1. Introduction 2. Design

More information

Since then, products have been introduced and expanded to include:

Since then, products have been introduced and expanded to include: ...in the beginning...baldor begins operations in St. Louis, MO. 1952 Baldor enters the world of servos (acquires Munich, Germany, and Minnesota facilities) 1990 1920 Baldor ships first adjustable speed

More information

BR Second Position Voltages. AA Fourth Position

BR Second Position Voltages. AA Fourth Position 1336S First Position Bulletin Number BR Second Position Voltage Letter AQ BR CW A B BP BX C Q R RX W Voltages 200-240V AC or 3V DC 380-480VAC or 513-620V DC 500-600V AC or 775V DC or 200-240V AC 380-480V

More information

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities. PART 1: GENERAL 1.01 This design guidelines contained herein includes the requirements electric motors utilized for electric motor driven systems at Texas State University. It is the intention of this

More information

Powerful + Efficient + Reliable

Powerful + Efficient + Reliable 1 THRU 50HP NEMA 140T THRU 449T HIGH EFFICIENCY ISO9001 CERTIFIED Powerful + Efficient + Reliable TEFC CAST IRON FRAMES CLASS F INSULATED 1.15 SERVICE FACTOR OVER SIZED BEARINGS LOW-LOSS ELECTRICAL GRADE

More information

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting

More information

Technical Specification For Outdoor Substation Harmonic Filter Banks

Technical Specification For Outdoor Substation Harmonic Filter Banks Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field

More information

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31,

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31, 5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA M1 (003) Part 31, DefinitePurpose Inverter Fed Motors Inverter Shield TM

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings

More information

1329I Integrated Drive/Motor CE Filter Option Kit

1329I Integrated Drive/Motor CE Filter Option Kit Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the

More information

Single-Phase Ventilated

Single-Phase Ventilated Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual Instruction Bulletin VD0C06N908C July 1998 Raleigh, NC, USA ALTIVAR 66, ALTIVAR 58, ALTIVAR 18 Dynamic Braking Resistor Kit User s Manual DANGER HAZARDOUS VOLTAGE Read and understand this bulletin in its

More information

AIR CORE REACTORS. Phoenix Electric Corporation

AIR CORE REACTORS. Phoenix Electric Corporation AIR CORE REACTORS Phoenix Electric Corporation PHOENIX ELECTRIC CORPORATION designs and manufactures Dry Type Air Core Reactors for operation on systems rated through 800 kv. All reactors are custom designed

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE The line of premium efficiency motors is now inverter capable. LEESON s unique IRIS voltage-spike-resistant insulation system is standard at no extra cost. motors

More information

High Performance Output Sine Wave Filter Installation, Operation, and Maintenance Manual

High Performance Output Sine Wave Filter Installation, Operation, and Maintenance Manual High Performance Output Sine Wave Filter Installation, Operation, and Maintenance Manual TCI, LLC W132 N10611 Grant Drive Germantown, Wisconsin 53022 Phone: 414-357-4480 Fax: 414-357-4484 Helpline: 800-TCI-8282

More information

Industrial Control Transformers

Industrial Control Transformers Industrial Control Types MTE and MTK.1 Standards and Certifications................................. Catalog Selection.................................. Type MTE...............................................

More information

MAX-E1 HIGH EFFICIENCY. Severe Duty

MAX-E1 HIGH EFFICIENCY. Severe Duty MAX-E1 HIGH EFFICIENCY Severe Duty DESIGN FEATURES & CONSTRUCTION ALL MAX-E1 MOTORS DELIVER THESE IMPRESSIVE DESIGN FEATURES HPE - High Pulse Endurance Wire Non-hygroscopic, Class F insulation system High-grade,

More information

VFD Best Practices: Getting the Most from Your VFD Investment

VFD Best Practices: Getting the Most from Your VFD Investment TECH TOPICS VFD Best Practices: Getting the Most from Your VFD Investment The purpose of this document is to outline best practices for successful application and installation of VFDs. Following these

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential power problems (spikes, surges

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

Industrial Control Power Transformers Class MT

Industrial Control Power Transformers Class MT Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

HPS Fusion General Purpose Enclosed Transformer

HPS Fusion General Purpose Enclosed Transformer HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio

More information

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS Hammond Power Solutions Inc. Page 1 of 1 ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS HPS Titan has been designed to operate in harsh environments/hazardous locations where dangerous gases, liquids,

More information

Product Selection 3-Pole Contactors

Product Selection 3-Pole Contactors - Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the

More information

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Solid-State Relays. Solid-State Relays. Features. Description. Overview Features Rugged, epoxy encapsulation construction 4,000 volts of optical isolation Subjected to full load test and six times the rated current surge before and after encapsulation Unique heat-spreader

More information

NORDIC-PREMIUM EFFICIENCY

NORDIC-PREMIUM EFFICIENCY CANADIAN STANDARDS ASSOCIAT ION EEV NORDIC-PREMIUM EICIENCY CAST IRON PREMIUM EICIENCY ELECTRIC MOTORS VD COMPATIBLE Meets or exceeds NeMA MG-1 table 1-1 premium efficiency corona & spike resistant MAGNet

More information

Features, Benefits and Functions

Features, Benefits and Functions -8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor

More information

Features and Benefits

Features and Benefits Features and Benefits ELECTRICAL DESIN z 1 500 HP; 2, 4, 6 pole z 3600, 1800, 1200 RPM z 3 Phase, 60 Hz, 460V z Motors can be rerated for 380, 400 and 415 VAC at 50 Hz. z Designed to meet NEMA M1, M13,

More information

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Solid-State Relays. Solid-State Relays. Features. Description. Overview Features Rugged, epoxy encapsulation construction 4,000 volts of optical isolation Subjected to full load test and six times the rated current surge before and after encapsulation Unique heat-spreader

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

Chapter 1: Getting Started User Manual Overview...1 2

Chapter 1: Getting Started User Manual Overview...1 2 Getting Started Chapter 1 Table of Contents Chapter 1: Getting Started User Manual Overview.........................................1 2 Overview of this Publication.........................................

More information

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature

More information

SUB-FHP AC GEARMOTORS PARALLEL SHAFT GEARMOTORS

SUB-FHP AC GEARMOTORS PARALLEL SHAFT GEARMOTORS SUB-FHP AC GEARMOTORS PARALLEL SHAFT GEARMOTORS 12-100 In-Lbs Single phase gearmotors, totally enclosed for continuous duty, general purpose applications. Permanent TEFC split capacitor designs are rated

More information

Transforming Energy.. For Advanced Technology

Transforming Energy.. For Advanced Technology Transforming Energy.. Manufacturers of CE approved Transformers & Reactors Five Decades of Manufacturing Experience Manufacturers of Quality Reliable Transformers. Auto C 201,4 th Cross Peenya Induatrial

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC The Z Series Zero-Fired SCR Power Controllers 60-1200 AMPS 120-600 VAC SCR Power controllers for resistance heating applications. ROBICON 1996 Rev. 7/96 Applications Robicon s Z series power controls are

More information

ATevo SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Variable Speed Product Line

Variable Speed Product Line Variable Speed Product Line BRCPVFD R1 Variable Speed Product Line Since 1997, CentriPro has been providing variable speed pump control solutions to its customers. The first product was the Aquavar variable

More information

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog Low voltage AC drives ABB micro drives ACS55 0.25 to 3 hp/0.18 to 2.2 kw Catalog ACS55 IP20 Overview ACS55 micro drives are designed for use in a wide variety of simple machinery applications where only

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight

More information

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection 7 Distribution Dry Type Transformers 600 Volts Class Single and Three Phase 600 Volts Class Single Phase 0.25 167 KVA Three Phase 3 1000 KVA Features Standard units are UL listed and are designed in accordance

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

Power Generation for the 21st Century

Power Generation for the 21st Century Power Generation for the 21st Century Generator Ratings: kw 118 to 2370 (60 Hertz) kva 136 to 2400 (50 Hertz) ISO 9002 Certified A Subsidiary of Regal-Beloit Corporation innovation, Since its market introduction,

More information

TA Ta VA CTRL-XFRMR

TA Ta VA CTRL-XFRMR 3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems 3 Uninterruptible Power Systems S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

Industrial Control Power Transformers

Industrial Control Power Transformers 09/10/15 Class MT Features b Enclosed coils (50-5000); Completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial

More information

HPS EnduraCoil. Cast Resin Transformer

HPS EnduraCoil. Cast Resin Transformer HPS EnduraCoil Cast Resin Transformer Hammond Power Solutions Inc. (HPS) is a leading manufacturer of standard and custom dry-type transformers in North America. Every HPS product is built with the quality

More information

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER Evo Series battery charger designed with YOU in mind. Evo Series battery charger is a next generation SCR-based utility battery charger. This evolutionary

More information