1 mtecorp.com dv/dt Filters dv Sentry Product Selector The future is here. The dv Sentry is like nothing you ve seen before. Our latest patented* technological innovation has made the dv Sentry the revolutionary solution for motor protection. ith its patented design, the dv Sentry is the first proven filter that provides common mode reduction, peak voltage protection and rise time reduction all in one unit. This gives Sineave Guardian Filters greater motor protection over time. It features a small footprint and easy terminations to make installation faster and easier. Plus, it runs quietly and radiates less heat than previous filters. The dv Sentry is unique, and when it comes to motor protection, there is nothing better. Matrix AP Line Reactors Ln Line Side dv Sentry Filters Load Reactors Utility Power armonic Filters VF Protection Power quality. Solved. US. Patent # 7,768,373
2 mtecorp.com ith the patented dv Sentry, you get the most advanced motor protection in its class. dv/dt Filters dv Sentry The unique design of the dv Sentry allows for greater load side protection from voltage spikes and common mode voltage for your AC motors, cable and VFs. Patented design provides over 50% common mode reduction, peak voltage protection, and rise time reduction - all in one filter. Low watts loss reduces heating in systems. Small footprint, with a unique flat design, allows filter to be easily integrated. Panel esign Strong robust design allows the filter to withstand installation and other difficult environments. Runs quieter, comparable to a normal conversation. Altitude erating Curve e know power quality, because power quality is all we do. Current erating Factor Current erating Factor Altitude (feet) dv Sentry Filter Current erating For rive Output Frequency Output rive Frequency ertz
3 dv Sentry Performance Specifications: Common Mode Reduction: Input Voltage 380V - 600V, 50/60z Current Range 3A - 600A Available Form Factors Panel NEMA 1/2 NEMA 3R Max Peak motor Voltage 150% of C bus voltage at 1000 feet Rise Time Less than 0.1uS ithout dv Sentry ith dv Sentry Insertion Loss Intermittent Current Ratings Carrier Frequency Range Frequency Agency Approvals Audible Noise Service Temperatures arranty No more than 1.7% at 60z No more than 2.6% at 90z 150% continuous RMS (1 minute) 200% continuous RMS (10 seconds) 3A - 110A: 900z -10kz (up to 14kz with derating) 130A - 600A: 900z - 5kz Up to 90z without de-rating Up to 120z with de-rating UL, cul, CE, and RoS Less than 65dB Enclosed -40C to 50C Open -40C to 60C TREE years from the date of shipment Peak Rise Protection: ithout dv Sentry ith dv Sentry Rise Time Reduction: Common Mode Reduction ithout dv Sentry ith dv Sentry Peak Voltage Protection Rise Time Reduction Modular esign
4 mtecorp.com Selection Tables: Select filters based on Full Load Amps (FLA) of the motor. If the FLA is greater than the current rating of the filter, use the next larger filter. Note: Resistors always included with purchase. No need to purchase separately. 380V K 480V P V P Amps Ratting Part Number eight (lbs.) OPEN Open (in.) ( X X ) Ref. Fig. atts Loss Resistor Resistors Resistor Size (in.) ( X X ) Ref. Fig VSP0003E x 6.7 x VSP0004E x 6.7 x VSP0007E x 6.7 x VSP0009E x 6.7 x VSP0012E x 6.7 x VSP0017E x 6.7 x VSP0022E x 6.7 x VSP0027E x 6.7 x VSP0035E x 9.0 x VSP0045E x 9.0 x VSP0055E x 9.0 x VSP0065E x 9.0 x VSP0080E x 9.0 x VSP0110E x 9.0 x VSP0130E x 13.6 x RESPANEL x 5.0 x 7.0 1A VSP0160E x 13.6 x RESPANEL x 5.0 x 7.0 1A VSP0200E x 13.6 x RESPANEL x 5.0 x 7.0 1A VSP0250E x 15.1 x RESPANEL x 5.0 x 7.0 1A VSP0305E x 15.1 x RESPANEL x 5.0 x 7.0 1A VSP0365E x 15.1 x RESPANEL x 5.0 x 7.0 1A VSP0415E x 15.1 x RESPANEL x 5.0 x 7.0 1A VSP0515E x 15.1 x RESPANEL x 5.0 x 7.0 1B VSP0600E x 15.1 x RESPANEL x 5.0 x 7.0 1B Note: Information is for reference only. Consult for detailed information.
5 dv Sentry Selection Tables: Select filters based on Full Load Amps (FLA) of the motor. If the FLA is greater than the current rating of the filter, use the next larger filter. Note: Resistors always included with purchase. No need to purchase separately. Amps Ratting Part Number eight (lbs.) NEMA 1/2 Size (In.) ( X X ) Enclosure Ref. Fig. Part Number eight (lbs.) NEMA 3R Size (In.) ( X X ) Enclosure Ref. Fig. 3 VSG0003E x 13.0 x 13.0 CAB-13V 6 4 VSG0004E x 13.0 x 13.0 CAB-13V 6 7 VSG0007E x 13.0 x 13.0 CAB-13V 6 9 VSG0009E x 13.0 x 13.0 CAB-13V 6 12 VSG0012E x 13.0 x 13.0 CAB-13V 6 17 VSG0017E x 13.0 x 13.0 CAB-13V 6 22 VSG0022E x 13.0 x 13.0 CAB-13V 6 27 VSG0027E x 13.0 x 13.0 CAB-13V 6 35 VSG0035E x 13.0 x 13.0 CAB-13V 6 45 VSG0045E x 13.0 x 13.0 CAB-13V 6 55 VSG0055E x 13.0 x 13.0 CAB-13V 6 65 VSG0065E x 13.0 x 13.0 CAB-13V 6 80 VSG0080E x 13.0 x 13.0 CAB-13V VSG0110E x 13.0 x 13.0 CAB-13V VSG0130E x 17.1 x 17.1 CAB-17V VSG0160E x 17.1 x 17.1 CAB-17V VSG0200E x 17.1 x 17.1 CAB-17V VSG0250E x 18.3 x 20.9 CAB-17AP VSG0305E x 18.3 x 20.9 CAB-17AP VSG0365E x 18.3 x 20.9 CAB-17AP VSG0415E x 18.3 x 20.9 CAB-17AP VSG0515E x 27.7 x 24.9 CAB-26AP VSG0600E x 27.7 x 24.9 CAB-26AP2 7 VS0003E x 10.9 x 12.0 CAB-10 8 VS0004E x 10.9 x 12.0 CAB-10 8 VS0007E x 10.9 x 12.0 CAB-10 8 VS0009E x 10.9 x 12.0 CAB-10 8 VS0012E x 10.9 x 12.0 CAB-10 8 VS0017E x 10.9 x 12.0 CAB-10 8 VS0022E x 10.9 x 12.0 CAB-10 8 VS0027E x 10.9 x 12.0 CAB-10 8 VS0035E x 10.9 x 12.0 CAB-10 8 VS0045E x 10.9 x 12.0 CAB-10 8 VS0055E x 12.5 x 22.9 CAB-12AP3 10 VS0065E x 12.5 x 22.9 CAB-12AP3 10 VS0080E x 12.5 x 22.9 CAB-12AP3 10 VS0110E x 12.5 x 22.9 CAB-12AP3 10 VS0130E x 18.3 x 26.0 CAB-17AP3 10 VS0160E x 18.3 x 26.0 CAB-17AP3 10 VS0200E x 18.3 x 26.0 CAB-17AP3 10 VS0250E x 18.3 x 26.0 CAB-17AP3 10 VS0305E x 18.3 x 26.0 CAB-17AP3 10 VS0365E x 18.3 x 26.0 CAB-17AP3 10 VS0415E x 18.3 x 26.0 CAB-17AP3 10 VS0515E x 27.7 x 30.0 CAB-26AP3 9 VS0600E x 27.7 x 30.0 CAB-26AP3 9 Note: Information is for reference only. Consult for detailed information.
6 mtecorp.com RESISTOR PANEL FIGURE 1A FIGURE 1B OPEN MAGNETICS FIGURE 2 FIGURE3 FIGURE 4 FIGURE 5
7 dv Sentry ENCLOSURES FIGURE 6 FIGURE 7 FIGURE 8 NOTE: OOS ONLY ON NEMA 3R ENCLOSURES FIGURE 9 Note: drawing dimensions are for reference only. See MTECORP.com for detailed information. FIGURE 10 NOTE: OOS ONLY ON NEMA 3R ENCLOSURES
8 mtecorp.com Simple, robust power quality solutions that are never over engineered. Power quality management requirements vary significantly. By utility. By industry. By application. By country. By site. That is why we offer a variety of power quality and filter products, for both input (line-side) and output (load-side) of Variable Frequency rives (VFs) and power conversion equipment. These components represent strategic parameters of power quality. e can provide you with a complete power quality solution. Ln Line Side Rl and Rl line/load Reactors help keep your equipment running longer by absorbing many of the power line disturbances which otherwise damage or shut down your inverters, variable speed controllers, or other sensitive equipment. The dv Sentry, with its patented Triple efense Core, is our latest technological innovation and the only proven filter that provides common mode reduction, peak voltage protection, and rise time reduction all in one unit. Ln Line Side MATRIX AP harmonic Filters can help ensure that your system meets the IEEE-519 requirements for harmonic current. Sineave Filters transform the output of your VF to a near perfect sinusoidal waveform for the best level of motor protection. Power quality. Solved. MTE Corporation N Leon Road Menomonee Falls, I (800) 455-4MTE (262) mtecorp.com Form VS-PSL-E 10/14 Supersedes VS-PSL-E 09/ MTE Corporation Printed in U.S.A.
Product Selector. The future is here. mtecorp.com. dv/dt Filters dv Sentry
mtecorp.com dv/dt Filters dv Sentry Product Selector The future is here. True common mode reduction, peak voltage protection, and rise time reduction orld leading motor protection technology in the market
More informationRLW. Reactors. mtecorp.com. Smaller, lighter protection. Power quality. Solved.
mtecorp.com RLW Reactors State-of the-art solution for absorbing everyday power line disturbances Smaller, lighter protection. Proven performance in the field Reliable and economical Compact and lightweight
More informationRLW Reactors. Product Selector. Smaller. Lighter. mtecorp.com. Proven performance in the field. Reliable and economical. Compact and light-weight
mtecorp.com RLW Product Selector Smaller. Lighter. Proven performance in the field Reliable and economical Compact and light-weight Ideal for OEMs, integrators and panel builders Our RLW Line/Load are
More informationdv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING
dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.
More informationM T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation
M T E C o r p o r a t i o n MTE Series RL Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL. 050516 2002 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RL Line/Load Reactors are components
More informationMTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090529 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW Line/Load Reactors are components designed to improve the
More informationSineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING
SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of
More informationM T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed
More informationMTE AC Line / Load Reactors Price book
Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 REACTOR SELECTION & PRICING...4 208-240 VOLT (3-PHASE)...4 400 VOLT (50 HZ) USE FOR 380-415 VOLTS...5 480 VOLT (3-PHASE) REACTOR...6
More informationAC Line / Load Reactors
AC Line / Load Reactors Table of Contents Delivery / Lead Time.PB03-1100 -2 Selection & Pricing PB03-1100 -4 Replacement Parts..PB03-1100-8 Product Modifications / Options..PB03-1100 -9 Product Specifications..PB03-1100
More informationM T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation
M T E C o r p o r a t i o n MTE Series RL Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL. 060227 2006 MTE Corporation Important User Information NOTICE MTE Series RL Line/Load Reactors are components
More informationM T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 040709 2003 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter
More informationM T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter
More informationHigh Frequency SineWave Guardian TM
High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation
More informationSeries A DC Link Chokes
Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 INTRODUCTION...3 LIST PRICE / CROSS REFERENCE...4 SELECTION & LIST PRICE...5 208 VOLTS (60 HZ)...5 240 VOLTS (60 HZ)...6 400 VOLTS
More informationREFERENCE MANUAL FORM: MX-TRM-E REL REV MTE
Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation
More informationSECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS
HPS CENTURION R REACTORS AND RC DV/DT FILTERS Single and Three Phase Why Choose a Line Reactor?... 98 Construction Features... 100 HPS Centurion R Reactors Specifications... 101 Part Number Guide... 102
More information1321 Power Conditioning Products
Technical Data 1321 Power Conditioning Products Don t Ignore the Cost of Power Line Disturbance Topic Page Product Overview 2 1321-3R and 3RA Series Line Reactors 3 1321 Reflective Wave Reduction (RWR)
More informationMATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation
MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 120628 REV. 007 2012 MTE Corporation Matrix Series D User s Manual 600VAC IMPORTANT USER INFORMATION NOTICE The MTE Corporation
More informationMATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation
MATRIX FILTER SERIES D 480 Volts, 60HZ USER MANUAL PART NO. INSTR 024 REL. 120628 REV. 012 2012 MTE Corporation Matrix Series D User s Manual 480VAC IMPORTANT USER INFORMATION NOTICE The MTE Corporation
More informationMatrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING
Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.
More informationMATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation
MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 080920 2008 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter is designed for harmonic mitigation
More informationMOTOR PROTECTION Sine Wave 2-8 khz Series A Filter Table of Contents
MOTOR PROTECTION Table of Contents Application & Selection Guides TR-1701-2 Selection: 440-480 VAC TR-1701-3 550-600 VAC TR-1701-4 Options Selection: Product Specification Model Number Code System Mechanical
More informationPRODUCT SPECIFICATIONS
KLR Series Three Phase Reactors PRODUCT SPECIFICATIONS Lifetime Warranty Performance Guarantee K-Rated, UL/ULC-Recognized; CSA-Certified 3 Phase, 600V Class Gapped Iron Core Inductor All Copper Windings
More informationMATRIX FILTER USER MANUAL. SERIES D 400 Volts, 50HZ PART NO. INSTR 025 REL REV MTE Corporation
MATRIX FILTER SERIES D 400 Volts, 50HZ USER MANUAL PART NO. INSTR 025 REL. 110624 REV. 006 2011 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter is designed for harmonic
More informationSince then, products have been introduced and expanded to include:
...in the beginning...baldor begins operations in St. Louis, MO. 1952 Baldor enters the world of servos (acquires Munich, Germany, and Minnesota facilities) 1990 1920 Baldor ships first adjustable speed
More informationThe Perfect Fit. Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive. usa.siemens.
The Perfect Fit Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive usa.siemens.com/perfectharmony When reliability is all you have room for. When it comes to improving throughput,
More informationTransforming Energy.. For Advanced Technology
Transforming Energy.. Manufacturers of CE approved Transformers & Reactors Five Decades of Manufacturing Experience Manufacturers of Quality Reliable Transformers. Auto C 201,4 th Cross Peenya Induatrial
More informationMatrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL
Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages
More informationChapter 1: Getting Started User Manual Overview...1 2
Getting Started Chapter 1 Table of Contents Chapter 1: Getting Started User Manual Overview.........................................1 2 Overview of this Publication.........................................
More informationASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.
ASHRAE - Variable Speed Drives By Dan Watkins, LEED BD+C Bornquist, Inc. Adjustable Frequency Drive Fundamentals How does a VFD actually work VS Pumping Analysis VS Pumping Features Harmonics VFDs and
More informationMX1S Matrix Converter
MX1S Matrix Converter Energy-Saving Medium-Voltage Drive with Power Regeneration 4.16 kv, 500 to 4000 HP, UL Listed Also available in 3 kv and 6kV Class Certified for ISO9001 and ISO14001 CERTI F I ED
More informationDescription Reactor, Open; 460 V 3 Phase; Power Rating 30 HP; Impedance 3 Percent; Inductance 0.7 Millihenry; Baldor Brand; Current Rating 45 Ampere
LRAC04502 Line Reactor Baldor Electric CO. Catalog Number LRAC04502 Manufacturer Baldor Electric CO. Description Reactor, Open; 460 V 3 Phase; Power Rating 30 HP; Impedance 3 Percent; Inductance 0.7 Millihenry;
More informationPhoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP
Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER
More informationWHY STACO ENERGY PRODUCTS?
PRODUCT PORTFOLIO WHY STACO ENERGY PRODUCTS? BECAUSE WE ARE YOUR TAILORED POWER SOLUTIONS PROVIDER! Unique application design demands, harsh environment concerns, the need to meet non-standard physical
More informationTECHNICAL DATA SHEET KVA UPS Systemss
Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800
More informationMatched drive-motor combination package
usa.siemens.com/drives Matched drive-motor combination package Integrated Drive Systems SINAMICS V20 and SIMOTICS GP100A Answers for industry. Why choose Siemens for your integrated drive system? Integrated
More informationSINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS
SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS SINGLE-PHASE SOLUTIONS INNOVATIVE UPS SOLUTIONS FOR CRITICAL APPLICATIONS Toshiba Uninterruptible Power Systems (UPS) features a specialized suite of
More informationINSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)
POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 480 Volts, 60Hz April 15, 2010: updated capacitor UL File number) Page 1 of 14 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Advantage
More informationTechnical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction
Technical brochure The Vector series The ABB comprehensive solution for automatic power factor correction 2 Applications The Vector series The Vector series The Vector series is a powerful and compact
More informationU1000. Low Harmonics Regenerative Matrix Converter EN DE U1000 U1000 U1000 U1000 U1000 U1000
Low armonics Regenerative Matrix Converter EN E Content 02 About YASKAA A Leader in Inverter rives Technology 03 - The rive for Maximum Efficiency 04 Compact and Effective 05 Features and Functions 06
More informationA Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications
A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications The Reliance Electric LiquiFlo AC drive combines high-performance variable speed drive technology with a patented liquid-cooling
More informationHPS Centurion R Reactor. Why Choose a Reactor? Connection Diagram
HPS Centurion R Reactor The new HPS Centurion R reactor provides a unique blend of improved performance and reliability while reducing the product footprint. HPS Centurion R reactors deliver protection
More informationModifiable TITAN Horizontal Motors Accessories and Modifications
36. Rotor, Standard And Optional Construction Standard rotor construction of 449, 5000 and 5800 frame TITAN products is typically die-cast aluminum. 720 RPM and slower is typically fabricated aluminum.
More information1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp
VS1MX AC Micro Drive 1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp & Controls 115 VAC 230 VAC 230 VAC 460 VAC 1 Phase - 50/60 Hz 1 Phase - 50/60 Hz 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications:
More informationProduct brochure. Medium voltage AC drive ACS 2000, 4kV 6.9kV HP
Product brochure Medium voltage AC drive ACS 2000, 4kV 6.9kV 300-2000 HP 2 ACS 2000 brochure ABB ACS 2000 simple and reliable motor control The ACS 2000 is the latest member of the ABB medium voltage AC
More informationUptime. All the time.
usa.siemens.com/perfectharmony Uptime. All the time. Siemens SINAMICS PERFECT HARMONY GH180 air-cooled drive Answers for industry. 13-SI-0186_brochure_Perfect Harmony Air-Cooled brochure_v7.indd 3 Downtime
More informationBRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life
BRAQCPC IT T Goulds Pumps AQUAVAR CPC Variable Speed Centrifugal Pump Controller Engineered for life Goulds Pumps Variable Speed Centrifugal Pump Controller 2 Introduction The Aquavar CPC (Centrifugal
More informationTHE DLS SERIES BATTERY CHARGING POWER CONVERSION
THE DLS SERIES IOTA s DLS Series Battery Chargers and Power Converters provide reliable AC/DC power conversion for a variety of application needs. With a record of proven performance throughout several
More informationDelta Products VFD CP2000 Bypass Control Packages.
Delta Products VFD CP2000 Bypass Control Packages www.deltaww.com Delta Products VFD CP2000 Bypass Control Packages The Delta Products VFD CP2000 Bypass Control Packages are designed for the Delta Products
More informationUninterruptible Power Systems
Sola 4K Industrial On-Line Uninterruptible Power Systems (UPS) The true on-line (double conversion) protection offered by the S4K Industrial UPS series eliminates a wider range of potential power problems
More informationStation Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)
Energy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX. 78721 (20) Sharp 208 W Modules = 4.16 kw 0.77/0.94*0.945=0.774 Derate Factor Station Identification City: Austin
More informationLow-Peak 600V Class RK1
LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:
More informationDefender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications
Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting
More informationA Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications
LiquiFlo AC Drives A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications The Reliance Electric LiquiFlo AC drive combines high-performance variable speed drive technology with
More informationA. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.
DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings
More informationLIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V
LIFT INVERTER SERIES EN DE ES FR IT 1000V YASKAWA INVERTER DRIVE TECHNOLOGY Contents Page 2 Introduction Experience & Innovation YASKAWA speaks Lift Page 3 YASKAWA Main Features Page 4 Specifications Page
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements
More informationDescription 1/8-7.5HP
Description 1/8-7.5HP J1000 In our pursuit to create drives optimized for variable speed needs in compact applications, the J1000 is the solution. This micro-drive is simple and reliable with Yaskawa quality.
More informationPowerFlex 6000 Medium Voltage AC Drives
PRELIMINARY INFORMATION PowerFlex 6000 Medium Voltage AC Drives Simple. More Reliable. Easy-to-use. User-friendly Control for Variable and Constant Torque Applications Cost-effective solutions for new
More informationEnclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures
Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking
More informationEKM Series Motors. For Aerospace & Defense Applications
EKM Series Motors For Aerospace & Defense Applications EKM Series Motors Table of Contents Introduction........................................................................................ 4 Introduction
More informationNetSure 701 Series DC Power System. DC Power for Business-Critical Continuity
NetSure 701 Series DC Power System DC Power for Business-Critical Continuity Key Features High Efficiency approaching 97%, esure rectifiers reduce power consumption for lower operating costs Modular Design
More informationAQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2
AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 INTRODUCTION The Aquavar Intelligent Pump Controller from utilizes an all new Aquavar platform, and combines it with over 20 years of
More informationUltra compact DC motor control. Non isolated.
340 340 0.55kw / 0.75hp 680 0.75kw / 1.0hp 1220 1.8kw / 2.0hp At a Glance 340, 680, 1220 series escription Ultra compact C motor control. Non isolated. Make upgrading your existing control panel easier.
More informationCONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS
LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low
More informationJ1000 D E F I 1000 J1000 J1000 J1000 J1000
Compact Inverter SERIES J1000 GB D E F I 1000 J1000 J1000 J1000 J1000 The J-Type YASKAWA Inverter Drive Technology Contents Page 2 Experience & Innovation A leader in Inverter Drives technology Page 3
More informationPowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations
Standalone three-phase UPS system PowerWave 33 S3 60 120 kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations Innovative technology delivering unmatched
More informationRegenerative DC Common Bus Supply
Regenerative DC Common Bus Supply The Regenerative DC Common Bus Supply supplies both motoring and regenerative current to the DC bus of one or more AC drives without the need of rectifier front end in
More informationSD Series. Cord and Light Reels. Engineered Solutions to Help you Work Smarter and Faster. Quality Cord and Light Reels
SD Series Cord and Light Reels Engineered Solutions to Help you Work Smarter and Faster Quality Cord and Light Reels Organize your work space for a safer, more productive work environment. Make Graco your
More information16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12
16kA Solid Dielectric, Triple Option Reclosers Providing electronic overcurrent protection for single or three phase operation on systems rated through 27kV, 630A continuous current, 16kA symmetrical interrupting
More information1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp
VS1MX AC Micro Drive 1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp & Controls 115 VAC 230 VAC 230 VAC 460 VAC 1 Phase - 50/60 Hz 1 Phase - 50/60 Hz 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications:
More information3 Uninterruptible Power Systems
S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential power problems (spikes, surges
More informationATevo SERIES BATTERY CHARGER
PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative
More informationAutomationDirect AC Motors Selection Overview
AutomationDirect AC s Selection (1992), High, What does it all mean? In 1992, the U.S. Congress passed legislation requiring that general purpose Design A & B motors meet minimum efficiency requirements,
More informationPOWER kva
TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power
More informationTECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)
TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power
More informationWARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.
SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.
More informationTECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)
TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5
More informationSINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS
SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS SINGLE-PHASE SOLUTIONS INNOVATIVE UPS SOLUTIONS FOR CRITICAL APPLICATIONS Toshiba Uninterruptible Power Systems (UPS) features a specialized suite of
More information300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds
Digital Soft Start Controls 9 thru 900 Amps 208-460V 50/60 Hz. 9 thru 900 Amps 208-575V 50/60 Hz. Applications: Controlled ramp start and stop, minimize spillage in material handling, reduced water hammer
More informationApplication Description
-14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....
More informationHVAC Products. Introducing the SED2 Variable Frequency Drives
HVAC Products Introducing the SED2 Variable Frequency Drives Designed Specifically for HVAC Applications From a global leader in drives technology and innovation, now comes a drive specifically configured
More informationCustomized drive solutions
Customized drive solutions Altivar 680 low-harmonic drive system 150 900 hp ND/125 700 hp HD altivardrives.com 2 altivardrives.com altivardrives.com 3 What will you get with drive systems? Whatever you
More informationCobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications
Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System
More informationEnergy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX (46) Sharp 208 W Modules = 9.
Energy & Cost Savings The Friends Meeting of Austin 371 Martin Luther King Blvd. Austin, TX. 78721 (46) Sharp 28 W Modules = 9.568 kw Station Identification City: Austin State: TX Latitude: 3.3 N Longitude:
More informationTECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)
TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5
More informationMidwest Dry Type Transformers
Midwest Electric Products Midwest Dry Type Transformers Reliable and Efficient Performance From a Name You Know DOE 2016 Efficiency Transformers Catalog General Information...2 General Purpose... 3 Single-Phase
More informationNetSure 701 Series DC Power System. DC Power for Business-Critical Continuity
NetSure 701 Series DC Power System DC Power for Business-Critical Continuity Key Features n n High Efficiency approaching 97%, esure rectifiers reduce power consumption for lower operating costs Modular
More informationDrive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer
Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer This document contains sample specifications for Liquid-Filled Type Drive Transformers You may
More informationStraight from the Engineer: Selling the KOHLER Advantages
Straight from the Engineer: Selling the KOHLER Advantages Kohler Generator Leadership Summit Breakout Session Billy Brandenburg and Chris Taylor 2-26-2018 KOHLERPOWER.COM / 1 Agenda Review what s most
More informationSolid Dielectric, Three Phase Reclosers CATALOG VS11
Solid Dielectric, Three Phase Reclosers Providing electronic, three phase overcurrent protection for systems rated through 38kV, 800A continuous current, 12.5kA symmetrical interrupting Reliable performance
More informationCapacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality
Individual & fixed capacitor banks Low Voltage L O W V O L T A G E N E T W O R K Q U A L I T Y Individual & fixed bank Capacitors Description High reliability Well proven features of ABB dry type power
More informationSYSDrive Frequency Inverter
SYSDrive Frequency Inverter T V/f control T PID control T Standard LED, optional LCD operator T Fieldbus options: DeviceNet T 7 configurable digital inputs T 3 configurable digital outputs T Low audible
More informationStandard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA
V Series 120/120VAC Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven
More informationMIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6
I. PART 1 GENERAL 1. SCOPE A. NEMA Premium copper-wound ultra low loss isolation transformer with a higher efficiency than that required by NEMA Std. TP-1. Optimized for energy efficiency over a wide load
More informationPOWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)
TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)
More informationFrequently Asked Questions. ABB low voltage drives Low Harmonic AC drives, 7.5 to 2800Hp
ABB low voltage drives Low Harmonic AC drives, 7.5 to 2800Hp Copyright 2009, ABB Inc. All Rights Reserved Specifications subject to change without notice Contact ABB Inc, Low Voltage Drives ABB Inc - Low
More informationPS AMA F (a) 0411 ( )
PS AMA F (a) 0411 (4.26.11) Table of Contents Body Style Versus Application...................................... 4 Flow Coefficients (Cv) Versus Travel................................. 4 Shut-Off P Ratings...............................................
More informationNon-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.
disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance