CASTIRONHUB&SPIGOT(SV)PIPE&FITTINGS ACCESSORIES

Size: px
Start display at page:

Download "CASTIRONHUB&SPIGOT(SV)PIPE&FITTINGS ACCESSORIES"

Transcription

1 PROUTTLO PROUTTLO STIRONNO-HUPIP&ITTINS STIRONHU&SPIOT(SV)PIP&ITTINS SSORIS

2 &I OUNRY OUT US bout Us &I oundry has been manufacturing cast iron soil pipe and fittings in merica since We produce a full line of standard and specialty cast iron soil pipe and fittings for drain, waste, and vent (WV) plumbing systems. &I also provides custom gray iron foundry services for OM manufacturers. ll of our quality products are proudly made in the US and meet all applicable STM and ISPI standards. Our basic principles embracing integrity and professionalism are what set us apart. Our Values t &I, we believe in... iving Team Members the chance to make decisions and learn from them Open communications and honest Team Member evaluations Sharing financial and business information with all Team Members Promoting a safe and enjoyable workplace The ability of every Team Member to make a positive contribution Sections of the 2,026 ft.² mural that surround &I oundry 1

3 The ull-line of ast Iron Pipe and ittings merica an Trust &I has been a leading West oast producer of cast iron drain, waste and vent systems for decades. Now the high quality pipe and fittings that have distinguished &I as an industry leader are available nationwide. ast Iron No-Hub Pipe and ittings ast Iron SV Pipe and ittings SV askets ccessories ll &I products are 100% made in merica. ll of our products have been carefully engineered to meet the most demanding industry standards, and are accepted for use by all plumbing codes in every jurisdiction in the United States. &I products are represented nationwide by an extensive network of ustomer Service professionals, Regional Sales Managers, and Manufacturer s Representatives, thoroughly dedicated to providing the highest level of customer service. NS-ertified to nsure ull Standards ompliance ll &I cast iron pipe and fittings have been certified by NS International to meet applicable ISPI and STM standards. s more and more products with questionable compliance records enter the domestic market, it is critical that engineers, contractors, and inspectors have the ability to distinguish between products that meet the standards and those that may not. NS ertification provides this assurance, giving all parties the peace of mind that comes from knowing they are installing unquestionably-compliant cast iron. ounding Member of the ast Iron Soil Pipe Institute (ISPI) &I has been a member of ISPI since its inception, and takes a great pride in helping sponsor this outstanding industry organization. ISPI has been instrumental in the promulgation of strong industry standards that have protected public health. ISPI conducts three unannounced, rigorous inspections of &I s products and operations annually. y having both ISPI and NS Marks, &I s products pedigree is second to none. 2

4 ST IRON VNTS ast Iron: The preferred choice for every application, above or below ground. NON-OMUSTIL, IR RSISTNT ast iron is non-combustible and fire resistant making it the safe choice for WV systems. ast iron is easy to install, and has superior durability often out lasting the life of a building. Its resistance to burning has the added benefit of requiring simple, low cost fire stopping between the annular space between the pipe and wall penetration. QUITR OPRTIONS ast iron is often referred to as the quiet pipe because of its inherent density it provides superior noise suppression. ast iron effectively suppresses annoying swooshing sounds that result from effluents cascading down from upper floors, resulting in a higher quality installation and a more satisfied customer. This sound attenuation feature can be a major benefit in quality residential and commercial construction, where building owners and tenants understand the advantage of iron by the very first flush. STRONR THN OTHR MTRILS ast iron is stronger, crush resistant, and longer lasting than any other WV piping material. ast iron pipe installed over 300 years ago in many of urope s landmark buildings is still serviceable today, attesting to iron s toughness and longevity. RSISTNT TO ORROSION ast iron has been proven to be resistant to corrosion, even in the harshest soil environments with the most challenging effluents. LOW THRML PNSION RTS ast iron expands and contracts in response to changing temperatures at a very low rate, reducing or eliminating the need for costly and time consuming expansion joints. 3

5 SUST SPIITION LOW R ll drain, waste, vent, sewer and storm lines shall conform to the requirements of ISPI Standard 301*, STM 888* or STM 74*. Pipe and fittings shall be marked with the collective trademark of the ast Iron Soil Pipe Institute or receive prior approval of the engineer. uilding or house sewers shall be of cast iron soil pipe and fittings from the building drain to the point of connecting with the city sewer or disposal plant. ll pipe and fittings shall conform to the requirements of ISPI Standard 301*, STM 888* or STM 74*. Pipe and fittings shall be marked with the collective trademark of ast Iron Soil Pipe Institute or receive prior approval of the engineer. OV R ll drain, waste, vent, sewer and storm lines shall conform to the requirements of ISPI Standard 301*, STM 888* or STM 74*. Pipe and fittings shall be marked with the collective trademark of the ast Iron Soil Pipe Institute or receive prior approval of the engineer. JOINTS No Hub ouplings shall conform to the ISPI Standard 310* and STM 1277 Heavy uty ouplings shall conform to the requirements of STM 1540 ompression askets for Hub & Spigot shall conform to the requirements of STM Standard 564* and STM 1563* Joints for pipe and fittings shall conform to the manufacturer s installation instructions and local code requirements * most current edition 4

6 TL O ONTNTS NO-HU SOIL PIP N ITTINS PTRS Hub dapter 11 Tapped dapter 11 xtended Tapped dapter 11 NS ¼ end 7 ¼ end w/ low heel inlet 7 ¼ end Tapped 7 ¼ end xtended 7 ¼ end w/extended low heel inlet 7 ouble ¼ end 7 ¼ end Short Sweep 7 xtended Short Sweep 7 ¼ end Long Sweep 8 1/5 end 8 1/6 end 8 ⅛ end 8 ⅛ end xtended 8 1/16 end 8 LNOUTS IO or errule 15 Iron ody Tapped leanout 15 Two Way leanout (Kelly) 15 Twin leanout (. ay ode) 15 Texas Twin leanout 15 LOST NS loset ends 18 loset ends Reducing 18 LOST ITTINS Vented loset Tee 17 Vented loset ross 17 LOST LNS loset lange 19 LOST RINS No Hub loset Rings 19 est Set loset Rings 19 ROSSS Sanitary ross 10 Sanitary Tap ross 12 IUR ITTINS igure 1 16 igure 5 16 igure 6 16 igure 6 ouble 16 igure 8 16 igure 8 ouble 16 PIP Silverspun No Hub Pipe 6 ITTINS lind Plug leanout itting 15 Prison itting 13 INRSRS/RURS Increasers Reducers 11 Reducer (Short) 11 SPIL ITTINS Rufwall 20 STRTR ITTINS Trim Packages TS Sanitary Tee 9 Sanitary Tap Tee 9 Test Tee 11 ouble Verticle Tapped Tee 18 Horizontal Twin San Tapped Tee 18 TRPS P Traps 14 Side Inlet P Trap 14 Running Trap w/ single vent 14 P Trap w/ double vent 14 eep Seal P Trap 14 P Trap Reducing 14 VNT YPSS 2 ypass Vent itting 13 WY Wye 12 omb Wye & ⅛ end 12 bl omb Wye & ⅛ end 12 ouble Wye 12 Upright Wye 12 Vented Tub Wye NH 13 Tapped Wye 18 HU & SPIOT PIP & ITTINS PTRS ouble Hub itting 35 R RT WITH LS 37 NS ¼ end 29 ¼ end w/ low heel inlet 29 ¼ end Reducing 29 ouble ¼ end 29 1/6 end 30 ⅛ end 30 1/16 end 30 Long ¼ end 29 Long ⅛ end 30 Long Sweep ¼ end 30 Single Hub Return end 30 Short Sweep ¼ end 29 LNOUTS Twin leanout (Memphis) 35 Two Way ouble leanout 35 LOST NS loset ends 37 loset ends Reducing 37 loset ends Regular Hub 37 loset end Tapped 37 LOST LNS loset lange 37 LOST ITTINS Vented loset Tee 39 Vented loset ross 39 ROSSS Sanitary ross 32 Tapped Sanitary ross 32 Straight Tapped ross 32 RRULS 2 11 Standard errule 37 SKTS Z TIT SV 44 Lubri/ast Lubricant 44 TY SL 44 TY SL Lubricant 44 TY Tools 44 INRSRS/RURS Reducer 35 Increaser 35 Long Plain Increaser 35 Long Tapped Increaser 35 PIP Hub & Spigot Pipe 28 PLUS Pipe Plug 35 SISSION INSRTL JOINT 38 STRTR ITTINS Trim Packages TPP SPIOT 38 TS Sanitary Tee 31, 38 Tapped Sanitary Tee 31 Straight Tapped Tee Test Tee (Type less plug) Test Tee (Type with plug) 36 Long San Tapped Tee 38 Tapped Long Sweep Tee 38 TRPS P Trap 36, 39 Running Trap 36 Running Trap w/ Single Vent 36 Running Trap w/ 2 Hub Vents 36 P Trap w/ ½ Heel Tap 36 eep Seal P Trap 36 VNT P WITH SRW 38 WY Wye 33 ombination & ⅛ end 34 ouble omb & ⅛ end Wye 34 ouble Wye 33 Wye with Side Inlet 34 Tapped Wye 38 Tapped ouble Wye 38 Tapped ath Vent Wye 38 WRRNTY INORMTION 48 5

7 QULITY SILVRSPUN NO-HU PIP SILVRSPUN 10 NO HU PIP The inest No Hub Pipe vailable! Part No. Size Unit Wt. Pcs/Pkg Total t. Pkg. Wt ½ x x x x x x x x x x IMNSIONS N TOLRNS NO HU PIP RRLS Inside J Outside T Thickness Size iameter iameter Norm. Min. 1½ 1.50± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ±

8 NO-HU ITTINS ¼ N Part No. Size Wt ½ 4¼ ½ ½ ½ ½ x 3 5½ 6 ¼ N W/LOW HL INLT Part No. Size Wt x / x 2 5½ 3¼ 9 ¼ N TPP Part No. Size Wt ½ x 1½ x 1¼ 3¼ 2¼ x 1½ 3¼ 2¼ x 2 3¼ 2¼ 2 ¼ N TN LOW HL INLT Part No. Size Wt x 2 15½ 5 10½ 8 OUL ¼ N Part No. Size Wt ½ ½ 12 ¼ N SHORT SWP Part No. Size Wt ½ ½ ½ ½ ¼ ¾ 122 ¼ N with 2 SI OPNIN Part No. Size Wt x 2 4 3¼ x 2 45/16 3¾ 8 ¼ N TN Part No. Size Wt x ½ x ½ x ½ x x x ½ 10 TN SHORT SWP Part No. Size Wt x ½ x ½ 11 7

9 NO-HU ITTINS 45 ¼ N LON SWP Part No. Size Wt ½ 9¼ ½ x 3 10½ ½ ½ ⅛ N Part No. Size Wt ½ 25/ ¾ / / / / / / /5 N Part No. Size Wt / / /16 7 ⅛ N TN Part No. Size Wt x x ¾ x ¾ x x x / /6 N Part No. Size Wt ¼ ½ /16 6 1/16 N Part No. Size Wt ½ 21/ / ¼ / / ¾ 14 8

10 NO-HU ITTINS Left Inlet SNITRY T (with 2 45 side opening above center) (New Orleans code) Part No. Size Wt LH 6 5 8½ RH 6 5 8½ RH & LH 6 5 8½ LH 6½ 5½ 91/8 5½ RH 6½ 5½ 91/8 5½ 9 SNITRY T Part No. Size Wt ½ 4¼ 4¼ 6½ x 1½ 4¼ 4½ 65/ ½ 4½ 67/ x 1½ 4¼ 5 6½ x 2 4½ 5 67/ x 2 4½ 5½ 67/ x 3 5 5½ ½ 5½ 91/ x ½ x 3 5½ 6 95/ x / ½ 6½ 117/ x 2 5 6½ 83/ x 3 5½ 6½ 93/ x 4 6 6½ 101/ x 5 6½ 7 11½ ½ x 3 6 7½ 103/ x 4 6½ 7½ 11½ x ½ x 6 7½ 8 13½ ½ 8½ 15½ 32 Right Inlet SNITRY T (with 2 90 side opening above center) (New Orleans code) Part No. Size Wt LH 4½ 6 5 8½ RH 4½ 6 5 8½ R&L 4½ 6 5 8½ LH 5 6½ 5½ 91/8 5½ RH 5 6½ 5½ 91/8 5½ R&L 5 6½ 5½ 91/8 5½ 10 SNITRY TP T Part No. Size Wt ½ x 1½ 3¼ 29/16 511/ x 1¼ 3¼ 213/16 511/ x 1½ 3¼ 213/16 511/ x 2 3¾ 31/6 63/ x 1½ 3¼ 35/16 511/ x 2 3¾ 39/16 63/ x 3 47/8 43/ x 1½ 3¼ 313/16 511/ x 2 3¾ 41/16 63/ x 3 4½ 43/ x 1½ 3¾ 45/16 611/ x 2 4¼ 49/16 715/ x 1½ 3¾ 413/16 6¾ x 2 4¼ 51/16 77/16 8 9

11 NO-HU ITTINS ront View SNITRY ROSS (with 2 45 sanitary opening same side) (New Orleans code) Part No. Size Wt ½ 91/8 5½ 11 Side View SNITRY ROSS Part No. Size Wt ½ 4¼ 4¼ 6½ ½ 4½ 67/ x 2 4½ 5 67/ x 2 4½ 5½ 67/ x 3 5 5½ ½ 5½ 91/ x 4 6 6½ 101/ ½ 7 21 SNITRY ROSS (with two 2 90 sanitary opening right & left above center) (New Orleans code) Part No. Size Wt ½ 6 5 8½ ½ 5½ 91/8 5½ 12 ront View Side View SNITRY TP ROSS Part No. Size Wt ½ x 1½ 3¼ 29/16 511/ x 1¼ 3¼ 213/16 511/ x 1½ 3¼ 213/16 511/ x 2 3¾ 31/16 63/ x 1½ 3¼ 35/16 511/ x 2 3¾ 39/16 63/ x 1½ 3¼ 313/16 511/ x 2 3¾ 41/16 63/8 8 SNITRY ROSS (with one 2" 90 sanitary openings above center) (New Orleans code) Part No. Size Wt ½ 5½ 91/8 5½ 11 10

12 NO-HU ITTINS TST T (LSS RSS PLU) IPS Part No. Size Tap Wt /8 33/ /16 7¾ 37/ /8 47/ ½ 11½ 5¾ ½ 6¼ ¼ 75/ ½ TST T WITH TYP RSS PLU INSTLL IPS Part No. Size Tap Wt /8 33/ /16 7¾ 37/ /8 47/ ½ 11½ 5¾ ½ 6¼ ¼ 75/8 34 HU PTR Part No. Size Wt ½ ¾ ¼ 5¼ 5 RUR (SHORT) Part No. Size Wt x 1½ 35/ x 2 35/ x 2 35/ x 3 35/ x x x x x x x 5 4½ x 2 4½ x 3 4½ x 4 4½ x x x 4 5½ x x x 4 6½ x 6 6½ x x 10 7½ x x x x 10 7½ x 12 7¾ 36 ½" ¼" INRSR - RUR Part No. Size Wt x TN TPP PTR Part No. Size Wt x 1½ x x 1½ x TPP PTR Part No. Size IPS Wt ½ x 1½ 25/8 1½ x 1½ 23/16 1½ x 2 25/ x 2 23/

13 NO-HU ITTINS WY Part No. Size Wt ½ /8 65/ x 2 55/16 65/8 1½ ¾ 8 2¼ x / x 3 6½ 8 111/ /16 9½ 27/ x 2 7½ 81/16 15/ x /16 111/ x 4 8½ 113/16 27/ ½ 125/8 31/ x 2 8¼ 85/16 ½ x 3 8¾ 9¾ 1¼ x 4 9¼ 113/16 115/ x 5 10¼ 12½ 29/ ¾ 141/16 35/ x 2 93/8 8½ 9/ x 3 913/16 95/16 1/ x 4 103/8 117/16 15/ x 5 113/8 1213/16 15/ x /16 143/16 215/ /8 171/8 3¾ x /16 125/8 ¾ x 6 131/8 157/16 23/ x /16 183/8 35/ ½ 21½ 51/ ¾ 25½ 5¾ ¼ 30 6¾ 204 OUL WY Part No. Size Wt /8 65/ x 2 51/16 65/8 1½ ¾ 8 2¼ x / x 3 6½ 8 111/ /16 9½ 27/ x 4 8½ 113/16 27/ x 4 9¼ 113/16 115/ ¾ 141/6 35/16 23a x 4 103/8 117/8 25/ x /16 143/16 25/ /8 171/8 3¾ 50 H UPRIHT WY Part No. Size H Wt ½ 8¼ x 2 5½ 83/16 1½ ½ 87/16 23/16 83/ x 2 5½ 8¼ x 3 5½ 87/16 111/16 83/ /8 27/16 9¾ x 2 6¾ /8 117/16 2¾ 2¾ 21 OMINTION WY & ⅛ N Part No. Size Wt ½ 4¾ 53/ x 1½ 5 57/ /8 65/8 65/ x 1½ 5½ 6¾ 65/8 1½ x 2 5½ 6¾ 65/8 1½ / ¼ x 2 5½ 7¼ 65/ x 3 7¼ 8½ 8 111/ ¼ 10 9½ 27/ x 2 515/16 7¾ 81/16 15/ x 3 7¾ 9 911/16 111/ x 4 9¾ 10½ 113/16 27/ ¾ 12½ 125/8 31/ x 2 6 8¼ 85/16 ½ x 3 73/16 9½ 9¾ 1¼ x 4 9¾ /16 115/ x / ½ 29/ /8 143/8 141/16 35/ x 4 97/16 115/16 113/16 7/ x /8 1315/16 2¼ ¾ 159/ /16 3¾ 53 OUL OMINTION WY N ⅛ N Part No. Size Wt /8 61/8 65/ x 2 5½ 6¾ 65/8 1½ / ¼ x 2 5½ 7¼ 65/ x 3 7¼ 8½ 8 111/ ¼ 10 9½ 27/

14 NO-HU ITTINS 183/8 6½ H VNT TU WY Part No. Size H Wt x 15 9½ 5¼ ¼ 2 VNT YPSS (right or left hand inlet) Part No. escription Wt PLIN RH LH / - L 11 9½ Right Shown H H VNT TU WY LH Part No. Size H Wt ½ 3¾ 16 8 VNT TU WY RH Part No. Size H Wt ½ 3¾ 16 8 PRISON ITTIN (with top vent and 2 opt. tap ) Part No. Size escription Standard starter for prisons and correctional construction. ouble 90 with single 2 top vent (9-502-). ully baffled. With tap Standard starter for prisons and correctional construction. ouble 90 with single 2 top vent (9-502). ully baffled. No Tap Standard starter for prisons and correctional construction. ouble 90 with three 2 top vent (9-505). ully baffled. No Tap. Part No. Wt ¼ 7¾ 11¾ 22 With Tap ¼ 7¾ 11¾ 22 No Tap ¼ 7¾ 11¾ 22 Plain 13

15 NO-HU ITTINS J 53/16 J P TRP Part No. Size J Wt ½ 6¾ 3½ ½ ½ ½ 6½ ½ 30 "P" TRP WITH 1½ TPP SI INLT Part No. Size Wt x 1½ LH x 1½ RH 6 P TRP (with tapped inlet) Part No. Size J Wt ½ 6¾ 3½ x 1½ 7½ ½ 4 5 LON P TRP Part No. Size J Wt x x M J P SL P TRP Part No. Size J Wt ½ ½ 8 17 J RUNNIN TRP (with 4 single vent) Part No. Size Wt x 4 6½ 4½ 15 10½ 20 P TRP (with ½ Tap Primer) Part No. Size J M Tap Wt ½ 4 2 ½ ½ 2 ½ ½ 6½ 2 ½ 18 J Top View J Side View Right Hand Illustration RUNNIN TRP WITH OUL VNT Part No. Size Wt ½ 4½ 15 10½ 21 P TRP (RUIN) Part No. Size J Wt x 2 9 5½ 10 P TRP (with 2 no-hub side inlet) Part No. Size J Wt LH 13/16 7½ 31/ RH 13/16 7½ 31/

16 NO-HU ITTINS LIN PLU Part No. Size Wt ½ 1¾ ¾ ¾ ¾ ¾ ¾ ¼ ½ ½ 33 TWO-WY LNOUT ITTIN (Kelly) Part No. Size Wt x 3 x 4 7½ x 4 x 4 93/16 9½ 183/8 26 IRONOY LNOUT (RRUL) (tapped) Part No. Size Tap Wt ½ 23/16 23/8 ¾ ½ 23/16 33/8 ¾ ½ 23/16 47/16 ¾ ½ 55/ ½ 65/ /8 83/ IO (errule) (with Type brass plug installed) Part No. Size Tapping Wt ¾ 1½ ¾ 2½ ¾ 3½ ¾ ¾ ¼ 6 10 TWIN LNOUT (ast ay code) Part No. Size Wt x 4 x 4 7½ 7½ 15 TS TWIN LNOUT Part No. Size Wt x 4 x 4 8¼ 2¾ 12 6½ 19 15

17 NO-HU ITTINS 45 IUR 1 Part No. Size Wt x 2 x 1½ x 1½ 47/8 33/ IUR 6 OUL W/ ULL L Part No. Size Wt x 2 79/16 51/ x 2 9 8½ H Left Shown IUR 5 Part No. Size Wt ½ x 2 x 3 87/8 69/16 9¼ /8 69/16 101/ x 2 x 4 10¼ 7¾ 11½ ¼ 7¾ IUR 8 RIHT/LT Part No. Size H Wt x 2 - right 79/16 51/ / x 2 - left 79/16 51/ / x 2 - right 9 6½ x 2 - left 9 6½ H 45 IUR 6 RIHT/LT Part No. Size Wt x 2 - right 79/16 51/ x 2 - left 79/16 51/ x 2 - left 9 6½ x 2 - right 9 6½ Left Shown IUR 8 OUL W/ ULL L Part No. Size H Wt x 2 79/16 51/ /8 37/

18 NO-HU ITTINS Left View VNT LOST T (RIHT OR LT) (with 2 top vent and 2 side inlet) Part No. Size Wt x4x2x2x4x4 RH 8⅛ 4¼ 5¼ 7½ 4 10½ 3¾ x4x2x2x4x4 LH 8⅛ 4¼ 5¼ 7½ 4 10½ 3¾ VNT LOST ROSS (with 2 top vent and 2 side inlet, no baffle) Part No. Size Wt x4x2x2x4x4 8⅛ 4¼ 5¼ 7½ 4 10½ 3¾ LOST ITTINS WITH 2 TOP VNT SIN TO US LOW TH LOOR (left hand, right hand or double) Part No. Size UP# Wt L ¾ 6½ 3¾ 4 4½ R ¾ 6½ 3¾ 4 4½ ** ¾ 6½ 3¾ 4 4½ 15 When ordering please specify Left, Right or ouble **ouble closet fitting has a baffle. 17

19 NO-HU ITTINS OUL VRTIL SNITRY TPP T Part No. Size H Wt x 1½ 213/16 9¾ 4½ 3¼ 4 HORIZONTL TWIN SNITRY TPP T Part No. Size H Wt x 1½ 1⅜ x 1½ 1⅜ H H LOST NS Part No. Size Wt x 4 x x 4 x x 4 x x 4 x x 6 x x 6 x x 6 x x 6 x x 10 x x 10 x x 10 x x 10 x x 12 x x 12 x x 12 x x 12 x x 16 x x 18 x LOST NS (RUIN) Part No. Size Wt x 4 x 6 x x 4 x 6 x x 4 x 6 x x 4 x 10 x x 4 x 10 x x 4 x 10 x x 4 x 12 x x 4 x 16 x x 4 x 18 x TPP WY Part No. Size Wt x 1½ 51/16 6⅝ x 2 51/16 6⅝ x 1½ 5¾ 6⅝ x 2 513/16 6⅝ x 1½ 67/16 6⅝ x 2 6½ 6⅝ 8 18

20 NO-HU ITTINS ST ST LOST RIN Part No. Size ox Qty Wt x 2 (with test cap) x x x 4 (with test cap) x 3 (with test cap) 12 3 LOST RIN (No-hub) Part No. Size Wt x 3 x 3½ 4 3 3½ x *Used with no-hub coupling 7¼ Min. Min LOST LN (caulk joint application) Part No. Size x Height Wt x1 6¼ 7¼ x1½ 6¼ 7¼ 1½ x2 6¼ 7¼ * 4x2 63/8 7¼ x2½ 6¼ 7¼ 2½ x3 6¼ 7¼ x4 6¼ 7¼ * 4x4 61/8 7¼ x5 6¼ 7¼ x6 6¼ 7¼ x2, 1 Offset x4, 2 Offset 6¼ 7¼ x3, 3 Reducing 6¼ 7¼ x2 6¼ 7¼ x4 x 4 6¼ 7¼ x3 x 2½ 6¼ 7¼ 2½ 3 *Portland ode, two ¼ taps on top 19

21 RUWLL NO-HU SPIL ITTINS Stack y-pass itting Long ouble Sweep San Tee Long Quarter end xtended San Tap Tee xtended Short Sweep Right Hand Single Starter itting Tub Vent Wye Side Inlet P-Trap RufWall Savings with ack Outlet ixtures (ompared with onventional Piping) ewer floor penetrations liminates cost of dropped ceilings to conceal pipe No scaffolding needed One-man installation Waist-high venting Water closet easier to intall...faster The by-pass fitting permits in-line piping to reduce width of the chase, and individual venting of the lavatories. Tub wye fittings accept waste from two tubs and provide a common vent. They save space, materials and the labor to install duplicate systems. NOT: Rufwall fittings are sold and shipped as normal cataloged soil products. This publication contains the information needed to place orders with your customer service representative. 20

22 STRTR ITTINS 10 L T 5½ T&L dimensions must be measured from the bottom of the fitting. NW YORK VRTIL STK STRTR ITTINS (long barrel) ZS 400 Part No. Size L T Wt. LT x ½ 6½ 5½ x ½ 4½ 6½ 5½ x ½ 6½ 5½ x ½ 4½ 6½ 5½ x ½ 6½ 5½ x ½ 4½ 6½ 5½ x ½ 4½ 6½ 5½ x ½ 6½ 5½ 6½ x ½ 4½ 6½ 5½ 6½ x ½ 6½ 5½ x ½ 4½ 6½ 5½ RIHT x ½ 6½ 5½ x ½ 4½ 6½ 5½ x ½ 6½ 5½ x ½ 4½ 6½ 5½ x ½ 6½ 5½ x ½ 4½ 6½ 5½ x ½ 6½ 5½ 6½ x ½ 4½ 6½ 5½ 6½ x ½ 4½ 6½ 5½ 6½ x ½ 6½ 5½ x ½ 4½ 6½ 5½ OUL x ½ 6½ 5½ x ½ 4½ 6½ 5½ x ½ 6½ 5½ x ½ 6½ 5½ x ½ 6½ 5½ 6½ x ½ 4½ 6½ 5½ 6½ x ½ 6½ 5½ x ½ 4½ 6½ 5½ *When ordering please specify Left, Right or ouble. 21

23 NO-HU ITTINS Part No. Size Z Wt. ZS LT L 4 x ½ 28 6½ L 4 x ½ 5½ 28 6½ L 4 x ½ 28 6½ L 4 x 28-8½ 5½ 28 6½ RIHT R 4 x ½ 28 6½ R 4 x ½ 5½ 28 6½ R 4 x ½ 28 6½ R 4 x 28-8½ 5½ 28 6½ OUL 21322* 4 x ½ 28 6½ * 4 x ½ 5½ 28 6½ * 4 x ½ 28 6½ * 4 x 28-8½ 5½ 28 6½ Trim package not included in price of fitting. *ouble starter fitting has a baffle. Z 6 inished loor Z & dimensions must be measured from the bottom of the fitting NO HU STRTR ITTIN WITH OR WITHOUT 2 NO HU INLTS (SIN OR US OV TH LOOR WITH K OUTLT WTR LOSTS) (left hand, right hand or double) THR STRTR ITTIN WITH OR WITHOUT NO-HU INLTS (SIN OR US OV TH LOOR WITH K-OUTLT WTR LOSTS) (left hand, right hand or double) Part No. Size Z Wt. ZS LT L 4 x ½ 28 6½ L 4 x ½ 5½ 28 6½ L 4 x ½ 28 6½ L 4 x 28-8½ 5½ 28 6½ RIHT R 4 x ½ 28 6½ R 4 x ½ 5½ 28 6½ R 4 x ½ 28 6½ R 4 x 28-8½ 5½ 28 6½ OUL 76088* 4 x 28" ½ 28 6½ * 4 x ½ 5½ 28 6½ * 4 x ½ 28 6½ * 4 x 28-8½ 5½ 28 6½ Trim package not included in price of fitting. *ouble starter fitting has a baffle. Z 4 IPS OPNIN inished loor 6 Z & dimensions must be measured from the bottom of the fitting. 22

24 TRIM PK OR STRTR ITTINS support leg ½ 3⅛ 12 3⅛ 6 4½ ⅝ 1 1½ ⅞ ⅝ 2⅜ ⅝ - 11 UN - 2 (5) places 67/32 7½ 1115/16 ⅝ 1¼ 9/16 ¾ 12⅜ R 213/16 ⅝ 1 R 311/16 R ⅞ 3¾ 3⅜ /32 1 1¼ 17/16 (6) places 19/16 front view 4½ 6¾.. 7¼.. ZS 22 TN L (left or right) 4½ ⅜ ⅝ ¾ 3 ⅞ 511/16 ½ - 13 UN - 2 (4) places 5/16 ½ side view 23/32 15/32 TYP 45/16 5⅝ ZS 22 SUPPORT L 20 2⅛ 4¼ ⅜ ⅜ 19⅞ 1 115/16 5⅝ 17¾ 67/16 side view ⅜ 3 TYP front view 2⅛ 23/16 23

25 TRIM PK OR STRTR ITTINS ZS 24 TRIM PK, WLL-HUN K-OUTLT SSMLY (to be used with PRT NO. ZS 22 support frame assembly) 1 4 PV Sch. 80 NIPPL with TST P 1 OWL SKT 4 ⅝ 12 ROS 4 ⅝ HROM P NUTS 8 ⅝ JM NUTS 4 ⅝ LT WSHRS 4 ⅝ IR WSHRS 3 ⅜ 1½ OLTS OR PLT 3 ⅜ LT WSHRS 4 ⅝ STR WSHRS ZS 22 N ZS 24 INSTLLTION INSTRUTIONS 1. INTIY TH MJOR OMPONNTS O TH ZS 24 TRIM PK N ZS 22 SUPPORT RM. 2. SUR ZS 22 SUPPORT RM TO INSTLL STRTR ITTIN USIN ⅜ 1½ OLTS N ⅜ LT WSHRS. 3. SUR RIHT N LT LS TO TH ZS 22 PLT USIN ½ 1¼ OLTS N ½ LT WSHRS IN POSITION SHOWN TO TH RIHT. 4. JUST SSMLY TO TH SIR HIHT. LVL N LIN TH SSMLY. 5. SUR TH T O TH ZS 22 SUPPORT RM TO TH LOOR USIN TH ½ 1¼ OLTS SUPPLI. 6. SUR SUPPORT L. OR OUL STRTR ITTINS, TH SUPPORT L IS NOT RQUIR. 7. SUR ⅝ 12 ZS 24 THR ROS TO PLT ORIN TO ZS 22 PLT. 8. INSTLL ZS 24 THR NIPPL TO TH ZS 700 OR ZS 800 ITTIN. ZS 23 TRIM PK, LOOR-MOUNT K-OUTLT SSMLY (note: not to be used with PRT NO. ZS 22 support frame assembly) 1 4 PV Sch. 80 NIPPL with TST P 1 OWL SKT 2 5/16 12 ROS 2 5/16 H NUTS 2 5/16 LT WSHRS 2 5/16 P NUTS 24

26 PIP & ITTINS INSTLLTION PROURS No-Hub oupling Installation Instructions racing To prevent movement, horizontal pipe and fittings 5 inches and larger should be suitably braced by the use of blocks, rodding or other suitable methods at every branch or change of direction. Test or best results, testing of one floor (ten feet) at a time is recommended. If more than one floor at a time is tested, the system should be properly restrained; all bends, changes of direction and ends of runs should be restrained. 1. Loosen screws, separate shield and sleeve. Slip shield over one spigot. oupling Material No-hub sealing sleeves (gaskets) are made of Neoprene conforming to STM 564. hemical characteristics of Neoprene assure that the gasket will not decay or deteriorate from contact with effluents in the pipe, or chemicals in the soil or air around the pipe. Material Specifications ands: Type 301 ISI Stainless Steel - Minimum tensile strength 165,000 psi. Screw Housing: Type 301 Stainless Steel, 5/16 hex head slant shoulder. Shield: Type 301 ISI Stainless Steel right annealed; Rockwell 100 (Vickers 240) minimum. Sealing Sleeve (asket): The sealing sleeve shall be tested in accordance with STM 3677 and be manufactured from a properly vulcanized virgin compound where the primary elastomer is polychloroprene (neoprene). 2. Insert spigots into sleeve. e sure that both spigots butt on center retainer inside sleeve. 3. Position shield over sleeve, tighten screws alternately to proper torque. 25

27 PIP & ITTINS INSTLLTION PROURS No-Hub oupling Installation Instructions ont. efore Joining 1. ouplings should be installed with a calibrated torque wrench set at 60 inch pounds (1½ 10 ) or 80 inch pounds (12 & 15 ). 2. When using field-cut pipe, the ends should be cut square. Joining Procedure 1. Install the Neoprene sealing sleeve on one end of the pipe or fitting to be joined. 2. Place the stainless steel shield over the other end to be joined. 3. Insert both ends into the sealing sleeve until they butt against the molded center stop, inside the sealing sleeve. 4. enter the shield over the sealing sleeve and tighten as directed below ½, 2, 3, 4 sizes. Tighten bands alternately to 60 inch pounds torque 5, 6, 8, 10 sizes. Tighten bands 2" 3" alternately to 60 inch pounds torque. Then bands #1 and #4 alternately to 60 inch pounds torque MIN M 12 & 15 sizes. Tighten bands 3 and 4 alternately to 80 pounds torque. Tighten bands 2 and 5 alternately to 80 inch pounds of torque. Tighten bands 1 and 6 alternately to 80 inch pounds of torque Min Max sizes. irst torque the minimum side and again. Then torque the maximum side and again. inally, torque 3 2 and 4 5 to 80 inch pounds LL HORIZONTL PIP N ITTINS, 5 INHS N LRR, SHOUL R TO PRVNT MOVMNT T VRY RNH OR HN O IRTION 26

28 PIP & ITTINS INSTLLTION PROURS utting Instructions or best results, use a Twin Lever Snap utter or a ratchet type cutter equipped with a sharp chain and equally spaced beveled cutting wheels. There are several methods that work well to cut ast Iron Soil Pipe. When using the Twin Lever Snap utter or ratchet type cutter equipped with a chain and cutter wheels, make sure that they are sharp and the wheels will rotate in the chain. When using a cutoff type abrasive saw, make sure to follow all safety procedures recommended by the manufacturer. t all times, read the safety instructions on any tool that is used to cut cast iron pipe. utting Procedure 1. Position chain around pipe so that the maximum number of wheels are in contact with the pipe. Too much space between the first and last wheel in contact with the pipe will produce a poor quality cut, so be careful when positioning the chain around the pipe. 2. Score the pipe before making the final cut, applying only enough pressure to make the cutter wheel create a deep scratch in the pipe. 3. Release the pressure and rotate the tool slightly; then apply a quick final pressure to complete the cut. To produce the best result, it may be necessary to score the pipe several times before making the final cut. Note: If the cutter wheels become flattened or dull, it will be very difficult (if not impossible) to obtain a satisfactory cut. The life of the chain can be extended by reversing the chain to obtain equal use of all the wheels. It is also important to keep the mechanical features of a cutter in good working order. Proper safety equipment and attire is required. 27

29 SV PIP &I US UP &I US UP 3½ Laying Length 5 Laying Length &I US UP NS-UPode 3½ T. Part No. Size Pcs/Pkg Unit Wt Laying Length SV SINL HU PIP 5 T. Part No. Size Pcs/Pkg Unit Wt T. Part No. Size Pcs/Pkg Unit Wt &I US UP J Y Telescoping Length Laying Length (see above) SV SINL HU PIP Telescoping Hub Hub arrel arrel Nominal Minimum Length I.. O.. O.. I.. Thickness Thickness Size Y J T T T L Laying Length OUL HU, 30 LNTHS Part No. Size L Pcs/Pkg Wt ½ L PIP, 5 LNTHS, OUL HU Part No. Size L Wt x 5 4 9½ x 5 4 9¼ x x x

30 SV ITTINS ¼ N Part No. Size Wt ¼ ½ ½ ½ /8 11½ /8 12½ ¾ * 15 10¼ 16½ 218 *H only 1 ¼ N w/low heel inlet Part No. Size 1 Wt x x 2 4½ 10½ 8 13 ¼ N, RUIN Part No. Size Wt x / x 2 7 3½ x 3 81/8 4¼ 10 LON ¼ N Part No. Size Wt x 12 3¼ x 18 3¼ x x 12 4½ x 18 4½ x 24 4½ ¼ N WITH SI INLT (cup hub inlet) Part No. Size Wt w/2 RH 8 4½ w/2" LH 8 4½ 17 SHORT SWP ¼ N Part No. Size Wt ¼ ½ ½ ½ /8 13½ /8 14½ ¾ OUL ¼ N Part No. Size Wt ½ 15 29

31 SV ITTINS LON SWP ¼ N Part No. Size Wt ¼ ½ ½ ½ /8 16½ /8 17½ ¾ * 15 15¼ 21½ 174 *H only 1/6 N Part No. Size Wt ¾ ½ 5½ /16 65/ /8 65/ /8 67/ / /16 99/ /16 N Part No. Size Wt /8 35/ /16 43/ /16 413/ /8 47/ ½ /16 611/ / /8 85/ * 15 25/8 87/8 78 *H only LON SWP ¼ N, RUIN Part No. Size Wt x x 3 9½ ⅛ N Part No. Size Wt ½ 4¼ /16 415/ /16 511/ /8 57/ /16 61/ / ½ 83/ /16 105/ * / / *H only J SINL HU RTURN N Part No. Size J Wt /8 5 57/ ½ 611/30 73/16 17 LON ⅛ N Part No. Size Wt x / x / x 12 23/ x 18 23/ x 18 29/

32 SV ITTINS 1 1 Left Shown SNITRY T Part No. Size Wt ¾ 6¼ x ½ x 2 9 4½ x ½ 7½ ½ x ½ x 2 9 5½ x ½ 7½ x ½ ½ x ½ 9¾ x ½ 10¾ /8 11¾ x ½ 9¾ x ½ 10¾ x /8 11¾ /8 12¾ x 6 16½ 8½ x 8 18½ 85/ x10 20½ 85/ ½ 8¾ * 15 25½ 10¼ 16½ x 8 18½ 101/ * H only SNITRY TPP T Part No. Size Wt x 1½ 8 213/16 6¼ x /16 6¼ x 1½ 9 35/ x / x /16 7¼ x 1½ 9 313/ x / x / STRIHT TPP T Part No. Size Wt x1½ 8 2 6¼ x ¼ x1½ 9 2½ x2 9 2½ x x x x2 12 3½ 77/ x4 12 3½ 8½ x2 13¼ 35/ x * # is the same as the Test Tee Less Plug SNITRY T WITH SI TP Part No. Size 1 1 Wt w/2 RH Tap ½ w/2 LH Tap ½ 17 SNITRY T WITH SI INLT Part No. Size 1 1 Wt w/2 RH ½ w/2"lh ½ SNITRY T WITH RIHT N LT HN SI TPS Part No. Size 1 1 Wt w/ ½ Left Shown 31

33 SV ITTINS SNITRY ROSS WITH 2 SI OPNIN Part No. Size 1 1 Wt ½ 27 TPP SNITRY ROSS Part No. Size Wt x 1½ 8 4¼ 6¼ x 2 8 4¼ 6¼ x 2 9 4¼ x 1½ x SNITRY ROSS (no baffle) Part No. Size Wt ¼ 6¼ x ½ x 2 9 4½ x ½ 7½ ½ x ½ x ½ 8 29 STRIHT TPP ROSS Part No. Size 1 Wt x 2 2½ x

34 SV ITTINS 1 1 WY Part No. Size 1 Wt x / ½ 5½ x 2 9 5¾ 35/ x 3 10½ 6¼ 47/ ¾ 5¼ x 2 9 6½ 31/ x 3 10½ 7 37/ x ½ 411/ ½ 8 5½ x 2 9 7¼ 29/ x 3 10½ 7¾ 33/ x ¼ 43/ x 5 13¼ 8¾ 415/ ¼ 5¾ x2 10½ 8½ 31/ x / x 4 13½ 9½ 4¾ x ½ x 6 16½ 10½ 65/ ½ 1113/16 711/ x ¾ 2¾ x 4 13½ 111/8 39/ x /8 45/ x 6 16½ 12½ 51/ x 8 19½ 137/16 6½ ½ 14½ x /16 41/ x 5 16½ 1215/16 47/ x /16 511/ x ¾ 71/ x /16 89/ /8 101/ x 4 15¼ 15 2½ x ¾ x /16 53/ x /8 67/ x /16 87/ * 15 31½ 20¾ 10¾ 333 *H only OUL WY Part No. Size 1 Wt x / ½ 5½ x 2 9 5¾ 35/ x 3 10½ 6¼ 47/ ¼ 5¼ ½ 8 5½ x 3 10½ 7 35/ x ¼ 43/ ¼ 5¾ x 4 13½ 9½ 4¾ x 6 16½ 10½ 65/ ½ 1113/16 711/ x 6 19½ 12½ 6½ x 8 19½ 137/16 6½ ½ 14½ x ¾ 71/ /8 101/ * 15 31½ 20¾ 10¾ 354 * H only 1 45 OUL WY WITH 2 SI OPNIN (cup hub inlet) Part No. Size H 1 Wt ¼ ¾ 32 H 33

35 SV ITTINS 2 Inlet H 1 WY WITH LT HN SI INLT (cup hub inlet) Part No. Size 1 1 Wt w/2 5 ¼ ¾ WY WITH RIHT HN SI INLT (cup hub inlet) Part No. Size 1 1 Wt w/2 5¼ ¾ 18 2 Inlet 1 OMINTION WY & ⅛ N Part No. Size H 1 Wt /8 8 47/ x 2 43/16 83/16 9 5¾ /16 10½ x 2 311/16 83/16 9 6¼ x 3 4½ 101/16 10½ 7½ ¼ 121/ x 2 33/8 83/8 9 6¾ x /16 10½ x 4 4¼ 75/ ½ ½ 119/16 13½ x 2 211/16 83/16 9 7¼ x 3 31/8 911/16 10¼ 8½ x 4 4¼ 121/ x 5 51/16 143/16 13½ 11½ ¾ 161/ / x 2 31/8 95/8 10½ 8¼ x 4 4¾ 131/16 13½ x 5 5½ 155/ ½ x 6 65/16 175/8 16½ 137/ /16 219/16 19½ H H OMINTION WY & ⅛ N WITH SI INLT Part No. Size H 1 Wt w/2 RH / w/2 LH / OUL OMINTION WY & ⅛ N Part No. Size H 1 Wt /8 47/8 73/ x ¾ 83/16 43/ ½ 51/ / x2 9 4½ 6¼ 83/16 311/ x3 10½ 59/16 7½ 101/16 4½ / /16 5¼ x /16 9½ 119/16 4¼ x / /16 4¼ /16 127/8 161/16 5¾ 80 34

36 SV ITTINS TWO-WY LNOUT (Memphis code) Part No. Size Wt /8 93/8 12¾ 35 TWO-WY OUL LNOUT Part No. Size J Wt /8 7½ 6½ 67/ x 4 135/8 8½ 6½ 67/16 35 J RUR Part No. Size Wt x 2 4¾ x x x x x x x x x x x x x x x x x 4 6½ x 6 6½ x 8 6½ x 10 6½ x 6 6½ x 8 6½ x 10 6½ x 12 6½ 65 LON PLIN INRSR Part No. Size Wt x 4" x 5" * 4 x 6" *not suitable for Ty-seal LON TPP INRSR Part No. Size Wt x 4" PIP PLU Part No. Size Wt ½ ¾ ½ ½ ¼ * 15 5¼ 51 *H only INRSR Part No. Size Wt x x x x x x 6 9½ x x x x OUL HU ITTIN Part No. Size Wt ½ ½ ½ * 15 1½ 87 *H only 35

37 SV ITTINS J 1 J J J P TRP Part No. Size J Wt ½ ½ ½ ½ 7½ ½ /16 11½ /8 113 RUNNIN TRP W/SINL HU VNT Part No. Size (Vent) 1 J Wt (3) 15 2½ 5½ (4) 17½ 3 6½ (4) 19½ 3½ 7½ (4) 21½ 4 8½ (6) 275/8 5¾ RUNNIN TRP Part No. Size J Wt ½ 6 6½ ½ 8 8½ 65 P TRP W/ ½ HL TP Part No. Size J Wt ½ ½ 3½ ½ 3½ 18 J P SL P TRP Part No. Size J Wt ½ ½ 41 J RUNNIN TRP W/OUL HU VNT Part No. Size (Vent) 1 J Wt (3-3) 15 2½ 5 5½ (4-4) 17½ 3 6 6½ (4-4) 19½ 3½ 7 7½ x4 (4-4) 19½ 3½ 7 7½ (4-4) 21½ 4 8 8½ (6-6) 21½ 4 8 8½ (4-4) 21½ 4 8 8½ (6-6) 275/8 5¼ (8-8) 315/8 6¼ (10-10) 38¾ 7¼ (12-12) 45¾ 8¾ 18½ 18½ TST T (SV less plug) Part No. Pipe Size Tap Size Wt ¼ /8 73/ ½ 111/ * 4 3½ 9 6¼ / * ¼ ¾ / / TST T W/ TYP PLU Part No. Pipe Size Tap Size Wt /8 73/ ½ 111/ * 4 3½ 9 6¼ * ¼ / ¾ / ** ½ 13 - * Short Laying Length ** Southern Raised Head 36

38 SV ITTINS 3½ Tap 2 11 STNR RRUL (less plug) Part No. Pipe Size Tap Size Wt ½ 3¼ ½ 3¾ ¼ ½ 4¼ ¼ ¼ ½ ½ ¼ * ¼ 45 *H only 2 11 STNR RRUL W/TYP PLU Part No. Pipe Size Tap Size Wt ½ 3½ ½ 3¾ ¼ ½ 4¼ ¼ ¼ ½ ½ ¼ * ¼ 47 *H only R RT WITH LS (series 547) Part No. Size Wt /8 2 LOST NS Part No. Size Wt x 4 x x 4 x x 4 x x 6 x x 6 x x 6 x x 6 x x 10 x x 10 x x 10 x x 10 x x 12 x x 12 x x 12 x x 12 x x 16 x x 18 x LOST NS (RUIN) Part No. Size Wt x 3 x 6 x x 3 x 6 x x 3 x 6 x x 3 x 10 x x 3 x 10 x x 3 x 10 x x 3 x 12 x x 3 x 16 x x 3 x 18 x LOST NS RULR HU Part No. Size Length Wt TPP LOST N WITH SOUTHRN O RSS PLU Part No. Size Wt ½ x / LOST LN (caulk joint application) Part No. Size x Height Wt x1 6¼ 7¼ x1½ 6¼ 7¼ 1½ x2 6¼ 7¼ * 4x2 63/8 7¼ x2½ 6¼ 7¼ 2½ x3 6¼ 7¼ x4 6¼ 7¼ * 4x4 61/8 7¼ x5 6¼ 7¼ x6 6¼ 7¼ x2, 1 Offset x4, 2 Offset 6¼ 7¼ x3, 3 Reducing 6¼ 7¼ x2 6¼ 7¼ x4 x 4 6¼ 7¼ x3 x 2½ 6¼ 7¼ 2½ 3 *Portland ode, two ¼ taps on top NOT: dhesive lubricants are required for TY-SL and Z-TIT gaskets in sizes 5 inch and larger diameters. 37

39 SV ITTINS SISSION INSRTL JOINT Part No. Size Wt ¾ ½ /8 9 57/ /16 8½ ¾ 37 SNITRY T WITH LNOUT ON MIN Part No. Size IPS Tap 1 Wt ½ 8 12⅛ 4½ 17 TPP WY Part No. Size 1 Wt x ⅝ x 1½ 5¼ 9 7⅞ x 2 5¼ 9 6⅞ TPP SPIOT Part No. Size Wt x 2 4¼ 5 LON SNITRY TPP T Part No. Size 1 Wt x 2 x /6 9 TPP OUL WY Part No. Size 1 Wt x 2 5¼ 9 7⅞ 16 2 Tap 2 Hub 2 Tap 45 2 Hub VNT P WITH ST SRW Part No. Size Wt Tap TPP LON SWP T Part No. Size Wt x 2 5½ 3⅛ 4 5⅝ 7 2 Tap TPP TH VNT WY Part No. Size Wt /16 51/64 3¼ 2½ 9 38

40 SV ITTINS J 45 Illustration Shows Right Hand P TRP WITH LNOUT RIHT SI Part No. Size J Wt ½ NOT: 3½ IPS tap. 3¾ SV 458 VNT LOST T WITH 2 TOP VNT N 2 TN SI INLT, RIHT HN OR LT HN Part No. Size Wt x4x2x2x4 RH 11 4½ 53/16 49/16 43/ x4x2x2x4 LH 11 4½ 53/16 49/16 43/16 38 J P TRP WITH LNOUT LT SI Part No. Size J Wt ½ 11 5½ 20 NOT: 3½ IPS tap. Not a baffled fitting SV 459 VNT LOST ROSS W/ 2 TOP VNT N 2 TN SI INLT Part No. Size Wt x4x2x2x4 11 6¼ 4¾ 47 2 Tap 2 Hub (SV) 3 Hub (SV) 2 Tap 4¾ VNT YPSS WITH 2 TPP SIS Part No. Size Wt x ½ 3¾ 3 5¼ 12 OUL SINK STK 770 Part No. Size Wt x2 15½ 4½ 6⅝ 4½ 5¾ x2 15½ 5¾ 7⅛ 4½ 22 39

41 SV ITTINS 4 SV Support ar 2 SV 4 NPT 2 Tap 2 Tap 5/16-18 UN ¾ ULL TH (2) HOLS 180 PRT 3⅜ ⅜ -16 UN-28 ULL TH (3) HOLS 120 PRT R SV 973R RIHT HN STRTR ITTIN WITH 4 TP N 2 TPP SI INLT Part No. Size Inlet Wt ½ 6½ 6½ 4 41/ ½ 9½ 6½ 4 41/ SV Support ar 4 SV 4 NPT 2⅞ 3⅜ ⅜-16 UN-28 ULL TH (3) HOLS 120 PRT R 2 Tap 2 Tap 5/16-18 UN ¾ ULL TH (2) HOLS 180 PRT SV 973L LT HN STRTR ITTIN WITH 4 TP N 2 TPP SI INLT Part No. Size Inlet Wt ½ 6½ 6½ ½ 9½ 6½ SV Support ar 4 SV 4 NPT 6½ Tap affle ⅜-16 UN-28 ULL TH (3) HOLS 120 PRT 5/16-18 UN R ¾ ULL TH (2) HOLS 180 PRT 2 Tap SV 975 OUL STRTR ITTIN WITH 4 TP N 2 TPP SI INLT Part No. Size Wt ½ 6½ /

42 SV ITTINS 2 SV Support ar 4 SV 4 SV Hub ⅜-16 UN-28 ULL TH (3) HOLS 120 PRT R 2 Tap 2 Tap 5/16-18 UN ¾ ULL TH (2) HOLS 180 PRT 2 Tap 2 Tap inished loor 41/6 2 Tap SV 974L LT HN STRTR ITTIN WITH 4 HU Part No. Size Wt with inlets 6½ 0 6½ with & inlets 6½ 18 6½ SV Support ar 2 SV Support ar 2 SV 2 Tap 2 Tap 4 NPT ⅜-16 UN-28 ULL TH 5/16-18 UN (3) HOLS ¾ ULL TH 120 PRT (2) HOLS R 180 PRT 2 Tap 41/6 45 inished loor 2 Tap 2 Tap Ø 3¾ SV 974R RIHT HN STRTR ITTIN WITH 4 HU Part No. Size Wt with inlets 6½ 0 6½ 41/ with & inlets 6½ 18 6½ 41/ SV Support ar 4 SV 4 NPT 2 Tap affle ⅜-16 UN-28 ULL TH (3) HOLS 120 PRT R 5/16-18 UN ¾ ULL TH (2) HOLS 180 PRT 2 Tap 2 Tap 2 Tap affle inished loor 45 2 Tap SV 976 OUL STRTR ITTIN WITH 4 HU N 2 TPP SI INLT Part No. Size Wt with inlets 6½ 0 6½ with & inlets 6½ 18 6½

43 TRIM PK OR STRTR ITTINS support leg ½ 3⅛ 12 3⅛ 6 4½ ⅝ 1 1½ ⅞ ⅝ 2⅜ ⅝ - 11 UN - 2 (5) places 67/32 7½ 1115/16 ⅝ 1¼ 9/16 ¾ 12⅜ R 213/16 ⅝ 1 R 311/16 R ⅞ 3¾ 3⅜ /32 1 1¼ 17/16 (6) places 19/16 front view 4½ 6¾.. 7¼.. ZS 22 TN L (left or right) 4½ ⅜ ⅝ ¾ 3 ⅞ 511/16 ½ - 13 UN - 2 (4) places 5/16 ½ side view 23/32 15/32 TYP 45/16 5⅝ ZS 22 SUPPORT L 20 2⅛ 4¼ ⅜ ⅜ 19⅞ 1 115/16 5⅝ 17¾ 67/16 side view ⅜ 3 TYP front view 2⅛ 23/16 42

44 TRIM PK OR STRTR ITTINS ZS 24 TRIM PK, WLL-HUN K-OUTLT SSMLY (to be used with PRT NO. ZS 22 support frame assembly) 1 4 PV Sch. 80 NIPPL with TST P 1 OWL SKT 4 ⅝ 12 ROS 4 ⅝ HROM P NUTS 8 ⅝ JM NUTS 4 ⅝ LT WSHRS 4 ⅝ IR WSHRS 3 ⅜ 1½ OLTS OR PLT 3 ⅜ LT WSHRS 4 ⅝ STR WSHRS ZS 22 N ZS 24 INSTLLTION INSTRUTIONS 1. INTIY TH MJOR OMPONNTS O TH ZS 24 TRIM PK N ZS 22 SUPPORT RM. 2. SUR ZS 22 SUPPORT RM TO INSTLL STRTR ITTIN USIN ⅜ 1½ OLTS N ⅜ LT WSHRS. 3. SUR RIHT N LT LS TO TH ZS 22 PLT USIN ½ 1¼ OLTS N ½ LT WSHRS IN POSITION SHOWN TO TH RIHT. 4. JUST SSMLY TO TH SIR HIHT. LVL N LIN TH SSMLY. 5. SUR TH T O TH ZS 22 SUPPORT RM TO TH LOOR USIN TH ½ 1¼ OLTS SUPPLI. 6. SUR SUPPORT L. OR OUL STRTR ITTINS, TH SUPPORT L IS NOT RQUIR. 7. SUR ⅝ 12 ZS 24 THR ROS TO PLT ORIN TO ZS 22 PLT. 8. INSTLL ZS 24 THR NIPPL TO TH ZS 700 OR ZS 800 ITTIN. ZS 23 TRIM PK, LOOR-MOUNT K-OUTLT SSMLY (note: not to be used with PRT NO. ZS 22 support frame assembly) 1 4 PV Sch. 80 NIPPL with TST P 1 OWL SKT 2 5/16 12 ROS 2 5/16 H NUTS 2 5/16 LT WSHRS 2 5/16 P NUTS 43

45 SV PROUTS TY SL LURINT Part No. Size Wt Quart allon 9 TY SL Wt. a. arton Pallet Part No. Size Lbs. Quantity Wt. Quantity Wt n excellent water-soluble joint compound. TY-SL LURINT has demonstrated its efficiency in millions of joints. Quick and easy to use under all conditions ven under water! vailable in quarts, gallons and 25 pound pails. LURI/ST LURINT Part No. Size Wt Quart 2.5 LURI/ST The unique LURI/ST formula makes joining TY-SL gaskets easier and faster because it s so slick! pplied as a liquid, LURI/ST actually reduces joining forces required; then it literally fastens the joint. LURI/ST is applied with an ordinary paint brush. It may be used for joining all pipe and fittings, and is required for joining all larger diameters 5 through 15. Z TIT Wt. a. arton Pallet Part No. Size Lbs. Quantity Wt. Quantity Wt TY TOOLS Joins Pipe pprox. Part No. escription Size Wt w/ 4 x 2 & 4 x 3 adapter 2, 3, " w/ 6 x 4 adapter 4, " w/ 8 x 6 adapter 6,

46 PIP & ITTINS INSTLLTION PROURS SV Hub & Spigot Installation Instructions Materials Needed Proper, approved equipment and attire: &I cast iron soil pipe and fittings TY Seal or Z Tight askets TY Seal Lube or Lubri/ast dhesive Lubricant TY Seal Lube for sizes 2 inches through 4 inches Lubri/ast dhesive Lube for sizes 5 inches through 15 inches rush for lubricant application Note: Lubri/ast dhesive Lubricant may be used on all sizes of pipe and fittings Lubri/ast is required when using 5 inches through 15 inches pipe and fittings Installation 1. lean the hub and pipe or fitting end to be joined. They should be free of dirt, mud, gravel, or other foreign material. 2. Insert the gasket into the hub. When joining 5 inches or larger pipe and fittings, apply Lubri/ast dhesive Lubricant to the inside surface of the hub before inserting the gasket. 3. Lubricant the inside surfaces of the gasket and the outside of the spigot end to be joined using a brush. (Use TY Seal Lube for sizes 2 inches through 4 inches. Use Lubri/ast dhesive Lubricant for sizes 5 inches through 15 inches). 4. lign the pipe and/or fittings to be joined. Push or pull the pipe or fitting spigot into the hub. You will feel the pipe or fitting bottom out at the hub. The assembly tool of your choice may be used. Note: If joining a cut piece of pipe, the sharp edges of the pipe must be peened with a hammer or filed to remove the sharp edge. ailure to remove the sharp edge on cut pipe will make assembly difficult. Note: ll gaskets specified meet or exceed the requirements of STM 564 and STM

47 PIP & ITTINS INSTLLTION PROURS aulking Instructions aulking Procedure 1. Insert the spigot end of pipe or fitting into the hub of pipe or fitting to be joined after wiping the hub and spigot with a clean cloth to assure the hub and spigot are clean and dry. 2. Yarn the oakum into the joint using a yarning iron. Some oakum comes in twisted lengths and may need to be separated into individual strands before yarning. Yarn and pack the oakum tightly using a packing iron to a depth of one inch below the top of the joint. Tightly packed oakum is essential for a leak free joint. Note: fter packing, make sure that no oakum fibers are sticking up into the area the lead will occupy. ibers in the lead area can cause leaks. 3. fter heating lead pot to a cherry red color, clean dross off the top of the lead and fill your ladle with clean, molten lead. Quickly pour the lead into the joint with one continuous pour, filling the joint completely. 4. fter the lead has solidified, the joint must be caulked to set the lead. Using your outside caulking iron, place the iron against the inner edge of the hub and caulk the lead completely around the circumference of the joint. fter caulking with the outside iron, you are ready to caulk using the inside iron. The inside iron should be placed against the pipe. aulk the lead completely around its circumference. Note: are should be taken to not crack the hub by caulking too heavily. Proper safety equipment and attire are required. &I oundry does not recommend the use of lead as it has been found to be hazardous to your health and the environment. 46

48 TH OUNRY O TH UTUR SIN 1906 rom humble beginnings over a century ago, &I has grown into a leading producer of cast iron pipe, fittings, and custom castings. ounded in 1906 by Joseph oscacci in his backyard, the foundry had its start producing decorative street lamps and brass statues to replace those destroyed in San rancisco s reat arthquake and ire. s the foundry grew, it began producing sash weights and other cast iron and brass products. With World War II approaching, it moved to its current location and modernized into a high production foundry. Managed by the founder s sons, the oscacci rothers began producing 9 ton submarine nets which spanned major ports on the West oast, including San rancisco ay. The post-war boom was led by unprecedented growth in construction, so foundry President rnold oscacci decided to begin making soil pipe and fittings on a large scale. To foster standards and higher quality, &I helped launch the ast Iron Soil Pipe Institute (ISPI) and pioneered the production of no-hub pipe and fittings. Today, &I is a thoroughly modern, technology driven foundry committed to environmentally responsible manufacturing and team member safety. The same focus on the olden Rule, personal relationships and customer service that built &I over the past century remains at the center of the company s culture, ensuring that &I will continue to be recognized as The oundry of the uture. Integrity That s the &I Way. Joseph oscacci rnold oscacci llan oscacci Kurt Winter Michael Lowe 47

49 WRRNTY &I products are guaranteed to be free from defects in material and workmanship, and to conform to applicable standards and requirements. &I s liability is limited to the replacement of defective material acknowledged by &I to be defective to be defective, and presented for claim within reasonable time limits. Material found defective will only be replaced; no labor charges or damages will be allowed. IMPORTNT NOTI: &I oundry will not be held responsible for any delays caused by work stoppage, trucking delays, raw material availability, acts of od or other unnatural causes beyond &I oundry s immediate control. WRNIN! Testing with compressed air or gas in ast Iron pipe and fittings may result in explosive failure and could cause severe injury or death. Tyler Pipe recommends hydrostatic testing as described in the ISPI Handbook. Never test ast Iron pipe or fittings with compressed air or gas! NOTS 48 48

50 NOTS 49 48

51 NOTS 50

52 ast Iron: Truly reen Pipe System y using ~100% post-consumer, recycled scrap iron as the raw material, &I pipe & fittings make a major positive contribution to the local environment, relieving the load on landfills and reducing the demand for energy by eliminating the need to mine and refine iron ore. dditionally, the majority of the iron used in the production of &I products originates within 500 miles of production plant, further minimizing &I s environmental footprint. our istribution enters Nationwide We understand that product availability and fast delivery are critically important to distributors and contractors alike. That s why &I has established a nationwide network of distribution centers that put the full range of &I products in close proximity. We certify that the cast iron soil pipe and fittings bearing our &I and I markings are merican manufactured and conform to the following specifications and reference standards: STM 888 STM 564 ISPI H 74 IPMO ile No O 4270 ederal Specification WWP 401 ISPI 301 NSI STM 74, SV Hub & Spigot ertified by NS to ISPI 301 Reference Standard & STM 74 rev 09/18 &I oundry 7825 San Leandro Street Oakland, /OT IRON ( ) ax: 510/ Ioundry.com L Service enter Nelson venue ity of Industry, 91744

No-Hub NH-ABI /4 Bend Short Sweep. SILVERSPUN 10 No-Hub Pipe. Extended Short Sweep. 1/4 Bend. 1/4 Bend Long Sweep. 1/4 Bend w/2 Side Opening

No-Hub NH-ABI /4 Bend Short Sweep. SILVERSPUN 10 No-Hub Pipe. Extended Short Sweep. 1/4 Bend. 1/4 Bend Long Sweep. 1/4 Bend w/2 Side Opening Part Pieces Pieces Lift List Inv Number Size Per Lift Weight Weight Price Code SILVERSPUN 10 No-Hub Pipe 00156 1-1/2 X 10 54 30 1620 138.30 A 00158 2 X 10 64 36 2304 138.70 A 00160 3 X 10 48 54 2592 191.40

More information

Hub & Spigot Pipe & Fittings Price List SV-ABI-2019

Hub & Spigot Pipe & Fittings Price List SV-ABI-2019 Part Size & Approx Pieces List Part Size & Approx List Number Description Wt Per Lift Price Number Description Wt Price Pipe, Single Hub, 3 - ½ Lengths 244059 2 X 3.5 15 102 81.15 244066 3 X 3.5 23 60

More information

Hub & Spigot Pipe & Fittings Price List SV-ABI-2018

Hub & Spigot Pipe & Fittings Price List SV-ABI-2018 Part Size & Approx Pieces List Part Size & Approx List Number Description Wt Per Lift Price Number Description Wt Price Pipe, Single Hub, 3 - ½ Lengths 244059 2 X 3.5 15 102 74.25 244066 3 X 3.5 23 60

More information

2. Top Inlet 3. Branch (Branches) or Side Openings 4. Length. RH (Right Hand) Fittings Illustrated

2. Top Inlet 3. Branch (Branches) or Side Openings 4. Length. RH (Right Hand) Fittings Illustrated HOW TO ORDER Guide To Ordering 1. To avoid errors, specify part numbers. 2. When selecting regular fittings, size of openings appear in this order: 1. Main 2. Branch or branches 3. When selecting reducing/increasing

More information

LIST PRICE. Tyler Cast Iron Soil Pipe & Fittings

LIST PRICE. Tyler Cast Iron Soil Pipe & Fittings Effective: July 1, 2018 Replaces: LP-DWV-2015 Dated: January 1, 2015 LIST PRICE Tyler Cast Iron Soil Pipe & Fittings Product...Pages PIPE & FITTINGS No-Hub... 2-8 No-Hub RufWall...9-11 Product...Pages

More information

LIST PRICE. Tyler Cast Iron Soil Pipe & Fittings

LIST PRICE. Tyler Cast Iron Soil Pipe & Fittings Effective: January 1, 2019 Replaces: LP-DWV-2018 Dated: July 1, 2018 LIST PRICE Tyler Cast Iron Soil Pipe & Fittings Product...Pages PIPE & FITTINGS No-Hub... 2-8 No-Hub RufWall...9-11 Product...Pages

More information

LIST PRICE. Tyler Cast Iron Soil Pipe & Fittings

LIST PRICE. Tyler Cast Iron Soil Pipe & Fittings LP-DWV-2081 Effective: January 2, 2008 Replaces: LP-DWV-2071 Dated: January 2, 2007 LIST PRICE Tyler Cast Iron Soil Pipe & Fittings Product... Pages PIPE & FITTINGS No-Hub... 2-6 NH RufWall... 7-9 Product...

More information

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS ICC-ES Report PMG-1220 Reissued 11/2017 This report is subject to renewal 11/2018 EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS DIVISION: 22 00 00 PLUMBING SECTION: 22 13 16 SANITARY WASTE AND VENT

More information

INSTALLATION OF OFF-THE-FLOOR FIXTURES

INSTALLATION OF OFF-THE-FLOOR FIXTURES 6 Closet Carriers INSTALLATION OF OFF-THE-FLOOR FIXTURES Many factors, including cost, material, labor required, space, handling and others must be thoroughly evaluated when planning an installation. With

More information

DWV PVC DWV Drain Waste Vent Fittings

DWV PVC DWV Drain Waste Vent Fittings STANDARDS & SPECIFICATIONS Standards provide greater assurance of product performance and consistency, and are available to assist design engineers in system specification. The most frequently referenced

More information

No-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates

No-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates Flexible Couplings Transitions all types of DWV plastic, copper, steel, cast iron and clay pipe. 300 series stainless steel clamps Flexibility - Sleeve is manufactured of molded natural and synthetic rubber

More information

EVERCONNECT TM. Table of Contents. No-Hub Pipe. Flexible. 7 Couplings. Pipe Caps. Heavy Weight. Test Plugs. Couplings. Shielded Transition

EVERCONNECT TM. Table of Contents. No-Hub Pipe. Flexible. 7 Couplings. Pipe Caps. Heavy Weight. Test Plugs. Couplings. Shielded Transition Table of Contents No-Hub Pipe Couplings Heavy Weight Couplings Shielded Transition Couplings 3 4 4 Flexible Pipe Caps Test Plugs Drain/Trap & Tubular Connectors 7 7 8 EVERCONNECT TM Flexible & Reducing

More information

DOUBLE ENVELOPING WORM GEAR SETS

DOUBLE ENVELOPING WORM GEAR SETS OUL NVLOPIN WORM R STS 172 one rive Product atalog and ngineering Manual ouble nveloping Worm ears & Speed Reducers ontents one rive ear Sets...173 one rive ear Sets - Tables of acklash... 174 one rive

More information

1-14 Fittings and Accessories

1-14 Fittings and Accessories -4 ittings and ccessories entricast Piping Systems NOV iber Glass Systems offers a complete line of fittings manufactured from both epoxy and vinyl ester resins. These fittings and adhesives provide the

More information

SUBMITTAL STANDARD NO-HUB COUPLINGS

SUBMITTAL STANDARD NO-HUB COUPLINGS SUBMITTAL STANDARD Date Architect Project Contractor Engineer PROFLO patented No-Hub Couplings are engineered to connect no-hub cast iron pipe in applications replacing the lessefficient hub & spigot material.

More information

COPPER FITTINGS FOR PLUMBING AND MECHANICAL APPLICATIONS

COPPER FITTINGS FOR PLUMBING AND MECHANICAL APPLICATIONS COPPER FITTINGS FOR PLUMBING AND MECHANICAL APPLICATIONS Job Name Job Location Engineer Contractor Wholesaler Streamline Rep Product Description: Streamline Wrot Copper Pressure and DWV fittings for use

More information

EXHAUST SYSTEM MANIFOLD AND ELBOWS 7 B

EXHAUST SYSTEM MANIFOLD AND ELBOWS 7 B EXHAUST SYSTEM 72990 MANIFOLD AND ELBOWS 72991 7 B Tl o Contnts P Torqu Spiitions..................... 7B-1 Slnts................................ 7B-1 Rmovl................................ 7B-1 Clnin n

More information

TABLE OF CONTENTS. Pipe Diameter Chart (Reference Only)..50 Extensions 38,40,42,44

TABLE OF CONTENTS. Pipe Diameter Chart (Reference Only)..50 Extensions 38,40,42,44 TABLE OF CONTENTS Item Page Item Page ANSI/AWWA Compact & Full Body Pipe Fittings: Product Submittals and Installation: Mechanical & Flange Joint C153. 3-9 20U Protective Fusion Bonded Epoxy....5,5 Mechanical

More information

Compression Fittings 36 Series Metric

Compression Fittings 36 Series Metric 6 Series 4 mm 28 mm O/ l l l l Wide range of types and sizes Rugged and durable Suitable for use under extreme conditions of pressure and temperature Ideal for most general industrial applications Technical

More information

Safety Stations with Eyewash

Safety Stations with Eyewash Safety Stations with yewash F G1942 Safety Station with yewash, Freeze and Scald Protection Valves pplication: ombination eyewash and shower safety station. Unit is furnished with temperature-actuated

More information

Watertight Wiring Devices

Watertight Wiring Devices atertight iring evices atertight and eather Protective evices for emanding nvironments Plugs and onnectors one seal adjusts to any cable range Triple bypass seal keeps water away from electrical connections

More information

Backwater Valves Series swing-check Backwater Valve shown installed in a manhole terminal.

Backwater Valves Series swing-check Backwater Valve shown installed in a manhole terminal. ackwater Valves 259 67800 Series swing-check ackwater Valve shown installed in a manhole terminal. 260 ackwater Valves JOSAM 67100A OAT AST IRON AKWATR, PLASTI ALL-LOAT, LASTOMR SAT, RONZ AG AN OTTOM OUTLT

More information

Safety Stations with Eye/Face Wash

Safety Stations with Eye/Face Wash Safety Stations with ye/face Wash F G1950 Safety Station with ye/face Wash, Stainless Steel owl pplication: ombination eye/face wash and shower safety station. Two large FS-Plus spray-type outlet heads

More information

Utilities Catalog. PC-U2008, February, 2008

Utilities Catalog. PC-U2008, February, 2008 Utilities Catalog PC-U2008, February, 2008 Tyler Utilities 11910 CR. 492 Tyler, Texas 75706 (800) 527-8478 Union Foundry Company Box 309 Anniston, Alabama 3602 (800) 226-7601 TABLE OF CONTENTS Item Page

More information

KIMAX. Laboratory Glass Drain and Vent Systems

KIMAX. Laboratory Glass Drain and Vent Systems KIMX Laboratory Glass rain and Vent Systems Index KIMX rainline Piping Systems for rain and Vent pplications 4 Technical ata 8 Guide Specifications 10 Pipe and Fittings 17 ouplings 18 Traps 21 ccessories

More information

VG95351E7. O-Ring for use with Style B flange mount connector Glenair, Inc. CAGE Code Printed in U.S.A.

VG95351E7. O-Ring for use with Style B flange mount connector Glenair, Inc. CAGE Code Printed in U.S.A. Series onnectors V95351 and V96934 Qualified onnectors V95351 and V96934 Qualified Products bout The V Specifications The erman ederal Office of efense Technology and Procurement (W) establishes procurement

More information

TABLE A AVAILABLE END CONNECTIONS. * 4, 6, and 8 Inch (DN100, DN150, and DN200) Valve Sizes. Nominal Valve Size

TABLE A AVAILABLE END CONNECTIONS. * 4, 6, and 8 Inch (DN100, DN150, and DN200) Valve Sizes. Nominal Valve Size Model V--00 larm heck Valve, 00 psi (0, bar) -/,,, & Inch (N5, N00, N50 & N00) Vertical or Horizontal* Installation eneral escription The Model V--00 larm heck Valves are divided seat ring, rubber-faced

More information

Plugs & Test Equipment for Piping Systems

Plugs & Test Equipment for Piping Systems Plugs & Test Equipment for Piping Systems Catalog CHERNE INDUSTRIES INC. 800.843.7584 www.cherneind.com Publication Date Mar. 2017 Cherne Industries Best in the Business From Humble Beginnings to an Industry

More information

Contents - Sliding Track

Contents - Sliding Track ontents - Sliding Track SLIING TRK Track Series 120 2 Track Series 200 2 Track Series 450 2 Track Series 650 2 HNGRS 2 Wheel Hangers 2 4 Wheel Hangers 2 SLIING OOR HRWR Top Plate ssembly 3 SI FIX RKTS

More information

CAST PIPE FITTINGS COUPLINGS

CAST PIPE FITTINGS COUPLINGS CAST PIPE FITTINGS COUPLINGS 00% Recyclable Recycled Content Environment Friendly 00% RECYCLABLE FIRE RATED SMOKE RATED Index HUBLESS SOIL PIPE Page TOOLS 4 5-6 7 35 8 8 9 0 5,6,25 8 2,24,25 26 27,28

More information

PLUMBING WHOLESALE CATALOG

PLUMBING WHOLESALE CATALOG PLUMBING WHOLESALE CATALOG PLUMBING WHOLESALE CATALOG CONTENTS Tube & Pipe Copper Tube............................8-9 Plastic-Coated Copper Tube.................10 Level Wound Copper Tube..................11

More information

Keymatic Line of Locks

Keymatic Line of Locks Volume 5 a t a l o g enstan L O O M P N Y eymatic Line of Locks 2 S V X Introduction 1 am Locks 2 3 rawer/oor Locks 4 Gang Locks 5 Snap olt Lock 6 s 7 8 9 10 11 Z olt Locks 12 Ratchet Locks 13 eys 14 enstan

More information

Worldwide Contacts.

Worldwide Contacts. Worldwide ontacts www.tyco-fire.com Model V--300 larm heck Valve, 300 psi (0, bar) -/,, & Inch (N, N0, N0 & N00) Vertical or Horizontal* Installation eneral escription The TYO Model V--300 larm heck Valves

More information

Valves & Flow Control Components Valves & Flow Control Components

Valves & Flow Control Components Valves & Flow Control Components Section 4 Valves & Flow ontrol omponents Valves & Flow ontrol omponents... 106 SJ-200 Low-Profile utterfly Valve... 107 SJ-300N utterfly Valve... 108 SJ-300F utterfly Valve (for Fire Protection)... 110

More information

Direct-Fired Heating, Ventilation and Pressurization Systems

Direct-Fired Heating, Ventilation and Pressurization Systems 2000-Series irect-ired Heating, Ventilation and Pressurization Systems imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% OUTSI IR ONLY 2000-Series Selection uide NOT: ll information

More information

MIN. DEPTH OF COVER TO TOP OF DUCTS (C) 450 mm CL 804 CL mm. 600 mm CL mm. 750 mm CL mm CL 804

MIN. DEPTH OF COVER TO TOP OF DUCTS (C) 450 mm CL 804 CL mm. 600 mm CL mm. 750 mm CL mm CL 804 ISO 9001: 008 NSI ertified 4 1 3 4 5 6 7 8 INISH SUR LVL PRMNNT RINSTTMNT TO OMPLY WITH LOL UTHORITY SPIITION / RWIN WRNIN TP X YLLOW MRKR WRNIN TP mm WI S O : 9590 OR TRNH KILL TILS RR 1 X R L MRKR (0

More information

The BEST Plumbing Specialties. One Source. B 1 Quality, Durability, reliability

The BEST Plumbing Specialties. One Source. B 1 Quality, Durability, reliability The BEST Plumbing Specialties. One Source. B 1 BraSS tubular Quality, Durability, reliability Since 1964 LYNCAR has manufactured and distributed high quality plumbing specialty items. In keeping with that

More information

WATER SOURCE HEAT PUMP WSHP

WATER SOURCE HEAT PUMP WSHP WTR SOUR HT PUMP WSHP I IR Water Source Heat Pump Units 3 onsole WSHP 4 onsole imensions 5 Vertical Stack WSHP 6 Vertical Stack imensions 7 Horizontal WSHP 8 Horizontal imensions 9 Vertical loset WSHP

More information

Kenstan. Volume 5. Knob Line of Locks. Introduction. Cam Locks. Drawer/Door Locks. Snap Bolt Lock. Plunger Lock PL40.

Kenstan. Volume 5. Knob Line of Locks. Introduction. Cam Locks. Drawer/Door Locks. Snap Bolt Lock. Plunger Lock PL40. Volume 5 a t a l o g L O K O M P N Y of Locks 2 S V Introduction 1 am Locks 2 3 rawer/oor Locks 4 Snap olt Lock 5 PL40 6 PL45 7 PL50 8 L O K O M P N Y List and ata Sheet Introduction 1 of Locks Standard

More information

ISOMETRIC VIEW SCALE: 1/2

ISOMETRIC VIEW SCALE: 1/2 NOTS:.. THIS RWING SRIS TH UL xx SRIS LTRONI UL PUMP. UNLSS OTHRWIS SPII, LL VIWS R MOLS -c, -c OR -c. TURS INLU: - THR PHS RUSHLSS MOTOR WITH NOYMIUM MGNTS - INTGRT LTRONIS WITH SP ONTROL - WT MOTOR SIGN,

More information

Water, Sewer & Drain Fittings

Water, Sewer & Drain Fittings Why Compact? Compact Joint are manufactured from a high strength, impact resistant ductile iron that offers a great margin of safety against service failures and provides vastly increased resistance to

More information

TYLER UNION. Quality Waterworks Products. PC-2017, March, REGISTERED FIRMISO 9001:2015. Tyler Union

TYLER UNION. Quality Waterworks Products. PC-2017, March, REGISTERED FIRMISO 9001:2015. Tyler Union TYLER UNION Quality Waterworks Products WATERWORKS CATALOG PC-2017, March, 2017 www.tylerunion.com 10014257 U L REGISTERED FIRMISO 9001:2015 CERTIFIED Tyler Union 11910 CR 492 TYLER, TEXAS 75706 (800)

More information

Plugs & Test Equipment for Piping Systems

Plugs & Test Equipment for Piping Systems Plugs & Test Equipment for Piping Systems Product Catalog CHERNE INDUSTRIES INC. Cherne Industries Best in the Business From Humble Beginnings to an Industry Standard In 1953, Cherne Industries created

More information

STEAM TRAPS. Float and Thermostatic Steam Traps (continued) Series C and X. Dimensions in. (mm)

STEAM TRAPS. Float and Thermostatic Steam Traps (continued) Series C and X. Dimensions in. (mm) STM TRPS loat and Thermostatic (continued) Series and X or large high capacity units s available: Series : 1 1 /4" NPT and SPT 1 1 /2" NPT and SPT 2" NPT and SPT 2 1 /2" NPT Series X: 2" NPT Resistant

More information

Acid Drainline Piping System

Acid Drainline Piping System Acid Drainline Piping System Chem Flowtronics 2 Corrosion Resistance Borosilicate glass is used as the material of choice in the chemical laboratory. Borosilicate glass remains today as the only material

More information

DOOR STOPS & HOLDERS DOOR TRIM & ACCESSORIES DOME DOOR STOPS CONVEX & CONCAVE WALL STOPS WALL MOUNTED DOOR STOPS ORDERING EXAMPLE: -26D C200 SERIES

DOOR STOPS & HOLDERS DOOR TRIM & ACCESSORIES DOME DOOR STOPS CONVEX & CONCAVE WALL STOPS WALL MOUNTED DOOR STOPS ORDERING EXAMPLE: -26D C200 SERIES OOR STOPS & HOLRS OOR TRIM & SSORIS OM OOR STOPS 00 8 9 Mounting hardware included inish: satin chrome (6) MOL NUMR 00 8 9 MTRIL Zinc die-cast 6 5/6 (4) 5/6 (33) 7/6 (36.5) /6 (7) I 3/4 (44.5) 7/3 () 7/3

More information

Direct-Fired Heating, Ventilation and Pressurization Systems

Direct-Fired Heating, Ventilation and Pressurization Systems 2000-Series irect-ired Heating, Ventilation and Pressurization Systems imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% Outside ir Only 2000-Series Selection uide M (m 3 /h)

More information

EXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS

EXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS 050-1 EXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS DESCRIPTION 2" 3" 4" 5" 6" 8" 10" 12" SH PIPE...(PER 5' LG) 157.26 191.24 229.95 385.68 379.55 566.58 1019.46 1356.09 SH PIPE...(10' LNGTH) 186.01 256.53

More information

2009 Edition. Tyton fittings 14"-24" NSF. For Water & Wastewater, Fire Protection & Industrial Applications. Certified to ANSI/NSF 61

2009 Edition. Tyton fittings 14-24 NSF. For Water & Wastewater, Fire Protection & Industrial Applications. Certified to ANSI/NSF 61 14"-24" Tyton fittings For Water & Wastewater, Fire rotection & Industrial Applications 2 Table of Contents TYTON Fittings 3 Assembly of TYTON Fittings 4 Bell Dimensions 6 Thickness and Dimensions 90 Bends

More information

ABS-0918 SUPERSEDES ABS-0318 ASTM D2661 R/SEPT ABS DWV FITTINGS.

ABS-0918 SUPERSEDES ABS-0318 ASTM D2661 R/SEPT ABS DWV FITTINGS. ABS-0918 SUPERSEDES ABS-0318 ASTM D2661 R/SEPT. 2018 ABS DWV FITTINGS www.bow-group.com COUPLING 1 1/4" 601112 125 9,000 5.63 1 1/2" 601120 125 9,000 3.48 2" 601138 100 4,800 4.65 3" 601146 45 1,440 13.07

More information

ABS DWV FITTINGS ABS-1116 NOVEMBER 2016 SUPERCEDES ABS-1215 ASTM D2661

ABS DWV FITTINGS ABS-1116 NOVEMBER 2016 SUPERCEDES ABS-1215 ASTM D2661 ABS DWV FITTINGS ABS-1116 NOVEMBER 2016 SUPERCEDES ABS-1215 ASTM D2661 COUPLING 1 1/4" 601112 125 9,000 3.36 1 1/2" 601120 125 9,000 2.25 2" 601138 100 4,800 3.03 3" 601146 45 1,440 8.49 4" 601153 25 800

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

STEP SAVING VALVES FOR THE PROFESSIONAL

STEP SAVING VALVES FOR THE PROFESSIONAL STP SVING VVS OR TH PROSSION RPS 4 OMPONNTS IMINTS 3 K PTHS SVS 27 MINUTS O OR liminate assemblies needed to isolate & drain any portion of a piped system Winterize an entire house with simple quarter-turn

More information

BROCHURE IP BI-TORQ Valve Automation PO Box 309 1N050 Linlar Dr. La Fox, IL tel: fax:

BROCHURE IP BI-TORQ Valve Automation PO Box 309 1N050 Linlar Dr. La Fox, IL tel: fax: ROHUR IP-209-0 I-TORQ Valve utomation PO ox 309 N050 Linlar r. La ox, IL 6047 tel: 630-208-9343 fax: 630-232-6235 www.bitorq.com 2-WY RSS VLVS /4 TO 4 LMP N SNITRY VLVS /2 TO 4 PGS 4-5 ITORQ.OM/IP.HTML

More information

Vertical Multi-stage Pumps - 60 Hz.

Vertical Multi-stage Pumps - 60 Hz. P erk.qxd 1/5/6 3:24 PM Page 1 Vertical Multi-stage Pumps - 6 Hz. PVM - ast Iron PVMI - 34 Stainless Steel PVMX - 316 Stainless Steel Models low Series HP Range GPM PVM/PVMI/PVMX 2 1/2 5 1 2 PVM/PVMI/PVMX

More information

THE GLOBAL LEADER IN PIPE PLUG & TESTING

THE GLOBAL LEADER IN PIPE PLUG & TESTING THE GLOBAL LEADER IN PIPE PLUG & TESTING PNEUMATIC PLUGS MECHANICAL PLUGS GAUGES TOOLS & ACCESSORIES TESTING EQUIPMENT 2 Oatey.com/Cherne TEST WITH THE BEST CHERNE TABLE OF CONTENTS PNEUMATIC PLUGS BLOCKING

More information

Discount Codes 07 DWV-PVC through 8 22 HVAC DWV - PVC. PVC Drain - Waste Vent Fittings. Includes: DWV - PVC - through 8 HVAC.

Discount Codes 07 DWV-PVC through 8 22 HVAC DWV - PVC. PVC Drain - Waste Vent Fittings. Includes: DWV - PVC - through 8 HVAC. Discount Codes 07 DWV-PVC through 8 22 HVAC DWV - PVC PVC Drain - Waste Vent Fittings Includes: DWV - PVC - through 8 HVAC s Effective: March 14, 2011 1 H x FPT H x MPT SP x MPT SP x SJ w/plastic Nut &

More information

Zurn Wilkins Fire Protection Series. Backflow Preventers, Pressure Regulating Valves, and Water Control Products for Fire Sprinkler Applications

Zurn Wilkins Fire Protection Series. Backflow Preventers, Pressure Regulating Valves, and Water Control Products for Fire Sprinkler Applications Zurn Wilkins ire Protection Series ackflow Preventers, Pressure Regulating Valves, and Water ontrol Products for ire Sprinkler pplications Zurn Wilkins ire Protection Series Zurn Wilkins fire protection

More information

GB-250. Submittal Specifications Installation Application Specific Details

GB-250. Submittal Specifications Installation Application Specific Details GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 68" (1,727 mm) 13½" (343 mm) 51½" (1,308 mm) 38" (965 mm) SUBMITTAL 33½" (851 mm) STANDARD: 4" plain

More information

M J G O.D. B.C. A B I.D. C O.D. A B C I.D. B.C.

M J G O.D. B.C. A B I.D. C O.D. A B C I.D. B.C. DI S TR Utility Pipe ittings and ccessories MJ ccessories NSI/WW 111/21.11 GLNDS, GSKETS, OLTS & NUTS GENERL SPEIITION MTERIL: PRESSURE: TESTING: DIMENSIONS: WEIGHTS: OTING: Ductile Iron per STM 536 350

More information

SUPER-MAX INDUCTION MOTOR

SUPER-MAX INDUCTION MOTOR SUPR-MX INUTIN MTR PRMIUM FFIINY SRIS PN RIP PRF FRM: 143T~5807N ompliance ertificate No.014 pplication: onstant torque 10:1 ariable torque 100:1 3-YR WRRNTY TTUN SUPRMX-P STNR FTURS PWR SUPPLY 3 phase,

More information

ABOUT NORTH AMERICAN PIPE CORPORATION

ABOUT NORTH AMERICAN PIPE CORPORATION Molded PVC Fittings TABLE OF CONTENTS D-SERIES: SOLVENT WELD DWV FITTINGS CERTS: ASTM D2665, F1866, F2135, CSA B181.2, UPC, NSF... 1-5 G-SERIES: GASKETED SDR 35 SEWER FITTINGS CERTS: ASTM D3034, ASTM

More information

ABS DWV FITTINGS FOR PLUMBING AND MECHANICAL APPLICATIONS

ABS DWV FITTINGS FOR PLUMBING AND MECHANICAL APPLICATIONS ABS DWV FITTINGS FOR PLUMBING AND MECANICAL APPLICATIONS Job Name Contractor Job Location Wholesaler Engineer Streamline Rep Product Description: Streamline ABS DWV ittings for use in applications including

More information

PRODUCT MANUAL GEARCAGE SYSTEM - ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS: Description

PRODUCT MANUAL GEARCAGE SYSTEM - ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS: Description Gearage -FP6 Hitch Rack TwinTube ased Slide-Out Mounting System PROUT MNUL Installation & Safe Use Operation Highlights Fits 2 size receiver hitches. Rated for 300 lbs of cargo payload. lass II minimum

More information

DECK FITTINGS DECK FITTINGS

DECK FITTINGS DECK FITTINGS ITTINS ITTINS TS R ONY SMP O SOM TYPS VI. MNY OTRS IN STO. T US NOW YOUR RQUIRMNTS! STOS IN T WST OST N T U. WWW.WTRMNSUPPY.OM MI PON X ITTINS SIN POINT MOORIN RRNMNT OR SIPS These requirements are applicable

More information

Models MSR-2424/MSR-3624

Models MSR-2424/MSR-3624 Molded one-piece construction for light weight and easy handling. Supplied with Wedge-Lok seal, integral drain and chrome strainer. Models MSR-2424/MSR-3624 Molded Mop Receptors Furnish and install molded

More information

:45 Pagina 5 Clamping

:45 Pagina 5 Clamping Clamping Clamping Wrenches The Original Heavy-Duty Pipe Wrench Ridge Tool, the world s leading manufacturer of pipe working tools, produces today millions of pipe wrenches with types and sizes to fit every

More information

VG95351 and VG96934 Qualified Connectors VG96934 TEN PIN CONNECTORS AND ACCESSORIES

VG95351 and VG96934 Qualified Connectors VG96934 TEN PIN CONNECTORS AND ACCESSORIES V95351 and V96934 Qualified onnectors Series onnectors V96934 TN PIN ONNTORS N SSORIS V96934 STYL ONIURTION SRIPTION P STYL able plug with two piece shielded backshell Page 30 STYL lange mount receptacle

More information

Vic -300 Butterfly Valves

Vic -300 Butterfly Valves R IPS RON STL PIP ROOV VLVS 08.0 Vic -300 utterfly Valves PROUT SRIPTION ear Operator 3" with Position andle Vic -300 butterfly valves are designed for pressures ranging from vacuum to 300 PSI (065 kpa).

More information

SINGLE ACTING TELESCOPIC

SINGLE ACTING TELESCOPIC SINGLE TING TELESOPI RM is pleased to offer a full line of standard telescopic designs for your equipment. These designs are pre-engineered using in stock material and internal components for quick order

More information

MAIN HYDRAULIC FLANGES AND COMPONENTS

MAIN HYDRAULIC FLANGES AND COMPONENTS TLOG 45 LNG PTR VRSION MIN HYRULI LNGS N OMPONNTS XPRIN: Over 55 Years of ependability 48,000 square foot State-of-the-rt manufacturing facility 4-bolt langes manufactured in the US QUI LIVRY: Over 5 Million

More information

CONNECTIONS MADE SIMPLE

CONNECTIONS MADE SIMPLE ONNTIONS M SIMPL omplies with all federal & state low lead laws No more solder, glue, clamps, costly tools or clean-up! Push-on connection to copper, PV or PX asily recover from installation & deburring

More information

SECTION C-C SCALE 1 / 2 SECTION E-E SECTION AT-AT SCALE 1 / 2 SCALE 1 / 2 SECTION F-F SCALE 1 / 2 SECTION M-M SCALE 1 / 2 DETAIL D SCALE 2 : 1

SECTION C-C SCALE 1 / 2 SECTION E-E SECTION AT-AT SCALE 1 / 2 SCALE 1 / 2 SECTION F-F SCALE 1 / 2 SECTION M-M SCALE 1 / 2 DETAIL D SCALE 2 : 1 RVIS PRT SRIPTION IN OM, TO MK - //0 Y.LI IT LRR 6 dded fillet at bottom of PM pocket in item. //0 TIO 4. R. dded a new part # //0 Y.LI T 4 (.7) Revised welding note at etail View /6/0 Y.LI WTR TIGHT Ø6.7

More information

G1994HFC Safety Station with WideArea Eye/Face Wash, Hand and Foot Control, All-Stainless Steel

G1994HFC Safety Station with WideArea Eye/Face Wash, Hand and Foot Control, All-Stainless Steel Safety Stations with Widerea ye/face Wash G1994HF Safety Station with Widerea ye/face Wash, Hand and Foot ontrol, ll-stainless Steel pplication: ll-stainless steel combination Widerea eye/face wash and

More information

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent Technical and Dimensional Data Saf-T Vent EZ Seal Single Wall L 29-4 Stainless Steel Special Gas Vent Tested and Listed to UL 1738/UL S636 by Underwriters Laboratories, Inc 5030 orporate Exchange lvd Grand

More information

HVACR WHOLESALE CATALOG

HVACR WHOLESALE CATALOG HVACR WHOLESALE CATALOG HVACR WHOLESALE CATALOG CONTENTS Tube & Pipe Copper Tube............................8-9 Plastic-Coated Copper Tube.................10 Level Wound Copper Tube..................11

More information

2 Exhaust Accessories

2 Exhaust Accessories 2 Exhaust ccessories U-olt Clamps.... 2-3 Guillotine U-olt Clamps... 2-3 Flat and U-olt Clamps.... 2-3 Round U-olt Clamps........................ 2-3 Welded Saddle U-olt Clamps... 2-3 ccuseal and Flat

More information

Fittings and Tubing. Low Pressure. Fittings and Tubing - Low Pressure. Low Pressure Fittings and Tubing Features: Pressures to 15,000 psi (1034 bar)

Fittings and Tubing. Low Pressure. Fittings and Tubing - Low Pressure. Low Pressure Fittings and Tubing Features: Pressures to 15,000 psi (1034 bar) ittings and Tubing Low Pressure Pressures to 15,000 psi (1034 bar) Since 1945 utoclave ngineers has designed and built premium quality valves, fittings and tubing. This commitment to engineering and manufacturing

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance

More information

UNION-TITE DUCTILE IRON C153 COMPACT FITTINGS

UNION-TITE DUCTILE IRON C153 COMPACT FITTINGS Sizes 4"-12" UL Listed for Fire Main Equipment SAMPLE SPECIFICATIONS (Current ANSI/AWWA revisions apply) 4" through 24" Push-On joint ductile iron fittings shall be produced in accordance with all applicable

More information

SUPERSEDES ABS-C0811/AUG.

SUPERSEDES ABS-C0811/AUG. ABS-C0612/R JUNE 2012 SUPERSEDES ABS-C0811/AUG. 2011 SANITARY TEE REDUCING TEE TEE - Left Side Inlet 600007 1 1/4" 0 62852 60000 5 50 4,800 15.41 600015 1 1/2" 0 62852 60001 2 90 2,880 8.27 600023 2"

More information

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

ABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS.

ABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS. ABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS www.bow-group.com dimension item Ctn Skid list price dimension item Ctn Skid list price SANITARY TEE (Hub x Hub x Hub) 1 1/4" 600007

More information

Flexible Couplings & Saddles

Flexible Couplings & Saddles Revised 6/01 Flexible Sewer couplings are the result of many years of experience with sewer pipe connections. Today's couplings are made of specially formulated elastomeric PVC with high tear and shear

More information

ABS-C0219 FEB SUPERSEDES ABS-C0717R CSA B181.1 ABS DWV FITTINGS.

ABS-C0219 FEB SUPERSEDES ABS-C0717R CSA B181.1 ABS DWV FITTINGS. ABS-C0219 FEB. 2019 SUPERSEDES ABS-C0717R CSA B181.1 ABS DWV FITTINGS www.bow-group.com DIMENSION ITEM CTN SKID LIST PRICE DIMENSION ITEM CTN SKID LIST PRICE SANITARY TEE (Hub x Hub x Hub) 1 1/4" 600007

More information

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508 Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:

More information

Section 8 AMERICAN. Flanged Pipe

Section 8 AMERICAN. Flanged Pipe Section 8 AMERICAN Flanged Pipe The principal standards covering Flanged Pipe are ANSI/AWWA C115/A21.15 and ANSI/AWWA C110/A21.10. These and other standards are referenced throughout this Section either

More information

VALVES, FIRE HYDRANTS, AND APPURTENANCES

VALVES, FIRE HYDRANTS, AND APPURTENANCES VALVES, FIRE HYDRANTS, AND APPURTENANCES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Butterfly Valves B. Gate Valves C. Tapping Valve Assemblies D. Fire Hydrant Assemblies E. Flushing Devices (Blowoffs)

More information

Manual Equipment. Manual Lever Hoists L 5 H V E. L5H or SLB Series ordering menu. 62 Air Winches & Hoists L5H150 L5H300 L5H600 L5H1200

Manual Equipment. Manual Lever Hoists L 5 H V E. L5H or SLB Series ordering menu. 62 Air Winches & Hoists L5H150 L5H300 L5H600 L5H1200 Manual Ingersoll Rand also offers manual trolleys to equip your small capacity hoists and manual hoists which are very useful for casual material handling work. Manual Lever Hoists L5H Heavy duty, high

More information

STEP SAVING VALVES FOR THE PROFESSIONAL

STEP SAVING VALVES FOR THE PROFESSIONAL STP SVING VVS OR TH PROSSION RPS 4 OMPONNTS IMINTS 3 K PTHS SVS 27 MINUTS O OR liminate assemblies needed to isolate & drain any portion of a piped system Isolate & drain an entire house with simple quarter-turn

More information

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent Technical and Dimensional Data Saf-T Vent EZ Seal Single Wall L 29-4 Stainless Steel Special Gas Vent Tested and Listed to UL 1738/UL S636 by Underwriters Laboratories, Inc 5030 orporate Exchange lvd Grand

More information

VB-9313 Series. Application. Features. Applicable Literature

VB-9313 Series. Application. Features. Applicable Literature V-9313 Series 2-1/2" and 3" Screwed NPT 2-1/2" to 6" 125 Lb. Flanged Three-Way Mixing s General Instructions pplication V-9313 series three-way mixing valves control hot or chilled water in heating or

More information

TRP International, Inc. CONTENTS

TRP International, Inc. CONTENTS ompany Profile Subsidiary Profiles Products TRP International, Inc. Throughout this catalog a TRP Service Mark appears next to those products manufactured by TRP. ONTNTS TRP International, Inc.......................................................

More information

PNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio

PNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio PNUMTI RK N PINION TUTORS dvanced torque to size ratio eatures: Pneumatic Rack and Pinion ctuators 90 ctuation for -way valves (Straight & ngle) 180 ctuation for -way (T-type) valves ctuators comply with

More information

FORGING AHEAD OF THE REST

FORGING AHEAD OF THE REST Bonney orge The Name You Trust for orged Steel Valves Bonney orge's forged steel valves and piping components have led the way for over eighty years in state-ofthe-art design and dependable performance.

More information

EXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS

EXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS 050-1 EXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS DESCRIPTION 2" 3" 4" 5" 6" 8" 10" 12" Sh Pipe...(Per 5' Lg) 164.20 215.30 240.20 423.40 396.60 591.99 1119.59 1489.39 Sh Pipe...(10' Lngth) 198.40 268.00

More information

Effective Date: January 2017 Void After: January Product: ABS-DWV Pipe and Fittings File No. 1909

Effective Date: January 2017 Void After: January Product: ABS-DWV Pipe and Fittings File No. 1909 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

866.DIP.PIPE P 1 NSF Edition. Certified to ANSI/NSF Edition 4" 36" REVISED 11.09

866.DIP.PIPE P 1 NSF Edition. Certified to ANSI/NSF Edition 4 36 REVISED 11.09 P 1 4" 36" For FIRE PROTECTION, Water & Wastewater P 2 Table of Contents TR FLEX Restrained Joint Pipe and Fittings 4"-36" 3 Suggested Specification Wording For 4"-36" Restrained Push-on Joint Pipe and

More information

hat channel purlins B SCREW PATTERNS: DOUBLE SCREW PATTERN ON UPPER AND LOWER ROOF PURLINS (FOR ROOF PANELS).

hat channel purlins B SCREW PATTERNS: DOUBLE SCREW PATTERN ON UPPER AND LOWER ROOF PURLINS (FOR ROOF PANELS). 6.2.524.524.524.524.524.524.524.524.524.524.524.524.524.524.524 3.2 +3.920 +3.094 note: dimensions including sheet metal transparent polymer panels, glass fiber enforced roof metal panel +3.920 +3.094

More information

How to Specify NH-39

How to Specify NH-39 Index Application Product Recommendation Backwater Valves 4200, 4300 Trap Primers 4401, 4402 Bladder Type Trap Seal Device 4405 Water Control Valve & Box 4440 Deep Seal P-Traps 4450 Adapters 4455, 4456

More information