1 Index Application Product Recommendation Backwater Valves 4200, 4300 Trap Primers 4401, 4402 Bladder Type Trap Seal Device 4405 Water Control Valve & Box 4440 Deep Seal P-Traps 4450 Adapters 4455, 4456 Water Hammers Arrestors / Shock Absorbers 4480, 4481 Air Gap Fittings 4490 How to Specify Series Number (Required) NH-39 Connection Type & Size (Required) Miscellaneous Options (As Needed) 02/01/19 Wade Drains CR 492 Tyler, TX (800) FAX (888)
2 4200 In-Line Backwater Valve NH Pipe Size B C G H T W 3" /2 3-1/8 5-5/8 5/8 4" 9 4-1/2 6-3/8 5-7/8 6-1/2 5/8 6" 14-1/2 6-1/2 8-3/ /8 Pipe Size Regularly Furnished Wt. Lbs. 3" $ " " Regularly Furnished: Cast iron backwater valve with bolted, gasketed cover, brass flapper and seat. Does not provide a positive seal. No-Hub 3NH,4NH,6NH N/C TC Threaded Plug Cover N/C 39 Galvanized Cast Iron $ Wade Drains CR 492 Tyler, TX (800) FAX (888) /01/19
3 4300 Internal Vertical Backwater Valve MJ Pipe Size A B C D Open Closed Open Closed Open Closed 3" 1-1/8 1/16 13/16 2-3/4 2-1/16 2-7/8 3-1/4 4" 1-1/8 1/ /16 2-1/ /16 4-1/16 Pipe Size Regularly Furnished Wt. Lbs. 3" $ " Mechanical Joint 3MJ,4MJ N/C Regularly Furnished: Vertical backwater valve with brass components, elastomer compression seal and elastomer float. 02/01/19 Wade Drains CR 492 Tyler, TX (800) FAX (888)
4 4401 Trap Primer (Replaces 2400-M, 2400-P) Regularly Furnished: Polished chrome plated bronze p-trap with stainless steel braided trap primer tube. Pipe Size Regularly Furnished Wt. Lbs. 1-1/4" x 1-1/2" $ P (-M) Slip Joint 114X112SJ N/C (-P) Threaded 114X112IPS N/C 282 Wade Drains CR 492 Tyler, TX (800) FAX (888) /01/19
5 4402 Trap Primer Valve and Distribution Unit 4402-NL-DU/IPS Regularly Furnished: Bronze trap primer valve with vacuum breaker. Style / Pipe SIze Regularly Furnished Wt. Lbs. Brass 1/2" $ (NL) No Lead Brass 1/2" DU/IPS 1/2 IPS Inlet x 3/8 IPS Threaded Outlets (4) $ DU/CJ 1/2 IPS Inlet x 1/2 CTS Compression Joint (4) Chrome Plated Valve Body Distribution Unit (Optional) 02/01/19 Wade Drains CR 492 Tyler, TX (800) FAX (888)
6 4405 Trap Seal Device Regularly Furnished: Elastomeric trap seal device with fitting for internal tailpiece or pipe installation. Pipe Size Regularly Furnished Wt. Lbs. 2",3",4" $ Connection Variations -2PVC Fits Inside 2" Sch.40 PVC/ABS Pipe N/C -2CI Fits Inside 2" Cast Iron Soil Pipe N/C -3PVC Fits Inside 3" Sch.40 PVC/ABS Pipe N/C -3CI Fits Inside 3" Cast Iron Soil Pipe N/C -4PVC Fits Inside 4" Sch.40 PVC/ABS Pipe N/C -4CI Fits Inside 4" Cast Iron Soil Pipe N/C -3TP Fits Inside 3" Strainer Shank (1100 Series) N/C -4TP Fits Inside 4" Strainer Shank (1000 Series) N/C -2G Fits Thru 2" Push-On Gasket Into Inside of Pipe N/C -3G Fits Thru 3" Push-On Gasket Into Inside of Pipe $ G Fits Thru 4" Push-On Gasket Into Inside of Pipe Wade Drains CR 492 Tyler, TX (800) FAX (888) /01/19
7 4420 No-Hub Coupling w/ Integral Test Cap NH Regularly Furnished: Bronze trap primer valve with vacuum breaker. Catalog Number Pipe Size Regularly Furnished Wt. Lbs NH 2" $ Regularly Furnished: Neoprene sleeve with stainless steel shield & removable test plug NH 3" NH 4" /01/19 Wade Drains CR 492 Tyler, TX (800) FAX (888)
8 4440 Water Control Box (Replaces 2440) FM Regularly Furnished: Surface mounted stainless steel remote water supply box with hot & cold water shut off valves, screwdriver stop, hinged cover with cylinder lock, & 1/2 copper sweat connections. Pipe Size Regularly Furnished Wt. Lbs. 1/2" $ FM Flush Mounted * N/C Suffix Description Deduct LMV Less Mixing Valve $ (1,484.00) 286 Wade Drains CR 492 Tyler, TX (800) FAX (888) /01/19
9 4450 Deep Seal P-Trap (Replaces 2450) NH Dimensions (Inches) Size Plug SIze A B C E G 2" 1-1/4 8-3/ /16 8-7/8 3-3/4 3" 1-1/4 10-1/ /4 4 4" 1-1/4 12-1/ /2 4-1/4 6" 1-1/2 15-1/ /4 18-5/8 4-5/16 Regularly Furnished: Cast iron deep seal trap with bottom bronze, gasketed plug, & 1/2 IPS pipe connection with plug. Pipe SIze Regularly Furnished -39 Galvanized Wt. Lbs. 2" $ $ " " ARC Acid Resistant Coating $ No-Hub 2NH,3NH,4NH,6NH N/C 02/01/19 Wade Drains CR 492 Tyler, TX (800) FAX (888)
10 4450-EF Funnel Drain with Deep Seal P-Trap (Replaces 2450-EF) 4450-EF-3NH Pipe Size A B C D E 2" 4-1/ /2 3" 6 3-5/ Regularly Furnished: Cast iron No-Hub deep seal trap with bottom bronze gasketed plug and round funnel. Pipe Size -1 Satin Finish Nickel Bronze Funnel -2 Satin Finish Bronze Funnel -12 Cast Iron Funnel Wt. Lbs. 2 $ $ $ ARC Acid Resistant Coating $ Galvanized Cast Iron No-Hub 2NH,3NH N/C 288 Wade Drains CR 492 Tyler, TX (800) FAX (888) /01/19
11 4455 Hub x IPS Adapter (Replaces 2400-H) IPS Pipe SIze B C 2" 4 2-1/2 3" 4 2-3/4 4" 4-3/4 3 Regularly Furnished: Cast iron male IPS thread to hub adapter. Pipe SIze Regularly Furnished Wt. Lbs. 2" $ " Galvanized Cast Iron 2,3,4 $ " Threaded 2IPS,3IPS,4IPS N/C 02/01/19 Wade Drains CR 492 Tyler, TX (800) FAX (888)
12 4456 No-Hub Adapter with Trap Primer Tap (Replaces 2400-NH) IPS Regularly Furnished: Cast iron adapter fitting with 1/2 IPS trap primer connection. Pipe Size Regularly Furnished -39 Galvanized Wt. Lbs. 2 $ $ Backwater Vlave (3 & 4 Only) $ /4 Trap Primer Tapping * N/C No-Hub 2NH,3NH,4NH,5NH,6NH,8NH N/C Thread x No-Hub 2IPS,3IPS,4IPS,5IPS,6IPS,8IPS N/C 290 Wade Drains CR 492 Tyler, TX (800) FAX (888) /01/19
13 4480 Stainless Steel Bellows Type Shock Absorber / Hammer Arrestor ANSI / ASME ASSE PDI A M WH-201 Regularly Furnished: All stainless steel shock absorber / hammer arrestor with welded, nested bellows. Temperature Range 100 F to 300 F. Max Operating Pressure 350 PSI. PDI SIze Pipe Size A B Fixture Units Regularly Furnished Wt. Lbs. A 3/4 3-1/4 3-1/ $ B 1 3-1/4 4-1/ C 1 3-1/4 4-3/ D 1 3-1/4 5-1/ E 1 3-1/ F 1 3-1/ Copper Piston Type Shock Absorber / Hammer Arrestor ANSI / ASME ASSE PDI A M WH A Regularly Furnished: Seamless copper shock absorber / hammer arrestor with polypropylene piston & EPDM O-rings. Max Temperature 250 F. Max Operating Pressure 350 PSI. PDI SIze 02/01/19 Wade Drains CR 492 Tyler, TX (800) FAX (888) Pipe Size A B Fixture Units Regularly Furnished Wt. Lbs. A 1/2 1-1/ $ B 3/4 1-1/8 7-1/ C 1 1-3/8 8-3/ D 1 2-1/ E 1 2-1/8 12-3/ F 1 2-5/8 11-1/
14 4490 Air Gap Fitting (Replaces 2490) TY Regularly Furnished: Cast iron, fixed air gap fitting with slip joint inlet. Outlet Size Regularly Furnished Wt. Lbs. 2 $ Galvanized Cast Iron $ Push On Gasket 2TY,3TY,4TY N/C 292 Wade Drains CR 492 Tyler, TX (800) FAX (888) /01/19
Specification Drainage Products Catalog and Price List
Drainage Specification Drainage Products Catalog and Price List Effective February 03, 2014 watts.com Drainage Products Standards C IAPMO U P C American National Standards Institute (ANSI) American Society
More informationSpecification Drainage Products Catalog and Price List
Drainage Specification Drainage Products Catalog and Price List Effective April 2, 2012 watts.com Drainage Products Standards C IAPMO U P C American National Standards Institute (ANSI) American Society
More informationPASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017
SECTION 221119 - DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Vacuum breakers. 2. Backflow preventers. 3. Water pressure-reducing valves. 4. Balancing valves.
More informationCNC DISTRIBUTION. ITEM NO Description Quantity
Valves CNC DISTRIBUTION Brass Ball Valves ITEM NO IPS Ball Valve *600# PSI WOG 150 PSI WSP * Heavy Pattern Forged Brass Construction *Full Port For Maximum Flow *Teflon Seats * Teflon Stem Packing * AGA,
More informationCNC DISTRIBUTION. ITEM NO Description Quantity. * 2ea Bolts and Nuts * Steel Hinged Body * Neoprene Gasket
Steel and Stainless Pipe Repair Clamp * 2ea Bolts and Nuts * Steel Hinged Body * Neoprene Gasket Steel Hinged Pipe Repair Clamp CNC1530 1/2 Steel Pipe Repair Clamp 10 CNC1531 3/4 Steel Pipe Repair Clamp
More informationFACILITY WATER DISTRIBUTION Revised 4/30/ Plumbing Systems
SECTION 22 11 00 - FACILITY WATER DISTRIBUTION PART 1 - GENERAL 1.1 SUMMARY A. This Section Includes: 1. Domestic water piping, within 5 feet of building. 2. Domestic water piping, above grade. 3. Pressure
More informationA. This Section includes the following domestic water piping specialties:
Page 221119-1 SECTION 221119 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationLIST PRICE. Tyler Cast Iron Soil Pipe & Fittings
LP-DWV-2081 Effective: January 2, 2008 Replaces: LP-DWV-2071 Dated: January 2, 2007 LIST PRICE Tyler Cast Iron Soil Pipe & Fittings Product... Pages PIPE & FITTINGS No-Hub... 2-6 NH RufWall... 7-9 Product...
More informationREPLACEMENT PARTS Quick Reference Guide
REPLACEMENT PARTS Quick Reference Guide For High Volume Products American Standard Customer Care 1-800-442-1902 2015 AS America, Inc. Printed in the U.S.A. SAH15B138 Effective October 1, 2015 Contents
More informationA. This Section includes the following domestic water piping specialties:
SECTION 221119 - DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following domestic water piping specialties: 1. Backflow preventers. 2. Water pressure-reducing
More informationLIST PRICE. Tyler Cast Iron Soil Pipe & Fittings
Effective: July 1, 2018 Replaces: LP-DWV-2015 Dated: January 1, 2015 LIST PRICE Tyler Cast Iron Soil Pipe & Fittings Product...Pages PIPE & FITTINGS No-Hub... 2-8 No-Hub RufWall...9-11 Product...Pages
More informationLIST PRICE. Tyler Cast Iron Soil Pipe & Fittings
Effective: January 1, 2019 Replaces: LP-DWV-2018 Dated: July 1, 2018 LIST PRICE Tyler Cast Iron Soil Pipe & Fittings Product...Pages PIPE & FITTINGS No-Hub... 2-8 No-Hub RufWall...9-11 Product...Pages
More informationLABORATORY SERVICE FIXTURES
Valve Selection Guide Provincial Lab Systems offers a wide selection of valves for use in the laboratory. The selection of a valve for any particular application depends upon many factors, including the
More informationZ x 17 Countertop Lavatory
Z5110 20 x 17 Countertop Lavatory TAG Z5110 Series 20" [508 mm] x 17" [432 mm] Vitreous china Faucet holes for single, 4" or 8" centers Self-rimming front overflow design Waste: 1-1/4" O.D. Depth: 6-5/8
More informationAnti Siphon Ballcock RP Anti-Siphon Ballcock
UR PS1115 Effective November 1, 2015 (SUPERCEDES PS0514 ) The issuance of this price list is not an offer to sell the goods listed herein at the prices stated. Anti Siphon Ballcock 109-603RP Anti-Siphon
More informationA. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.
SECTION 220523 - PLUMBING VALVES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Ball valves. 2. Butterfly valves. 3. Swing check valves. 4. Spring loaded check valves. 5. Water pressure reducing
More informationBid # Plumbing Supplies RESULTS
BOARD APPROVED Bid # 15-4 - Plumbing Supplies Page 1 of 16 Grant Plumbing North Brunswick NJ PVC PIPE, SCHEDULE 40 1 1-1/4" PVC Pipe, SCH 40, 20' feet 60 $0.598 $35.88 2 1-1/2" PVC Pipe, SCH 40, 20' feet
More informationSegment Name: CAST IRON 22X18 SERVICE SINK
Segment Name: CAST IRON 22X18 SERVICE SINK Segment Code: Features KOHLER cast iron Acid resistant enamel finish Single compartment With rim guard 22-1/4 (56.5 cm) x 18-1/4 (46.4 cm), or 24 (61 cm) x 20-1/4
More informationNo-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates
Flexible Couplings Transitions all types of DWV plastic, copper, steel, cast iron and clay pipe. 300 series stainless steel clamps Flexibility - Sleeve is manufactured of molded natural and synthetic rubber
More informationCNC DISTRIBUTION CNC955
Bath and Shower Components CNC930 C.P. Push Pull Diverter 25 CNC955 C.P. Positive Shut Off 25 CNC997 C.P. Inline Vacuum Breaker 25 CNC3580 Brass Twin Ell 25 CNC3585 Bent Bathcock Couplings 25 CNC3581 Drop
More informationPLUMBING VALVES TOTAL MAINTENANCE SOLUTIONS
BRONZE STOP VALVES Domestic Import 40300283 1/4 Iron pipe thread 57842032 3/8 Iron pipe thread 40300284 1/2 Iron pipe thread 57021034 40300285 3/4 Iron pipe thread 57021036 BR ONZE GATE VALVES 125 psi.
More informationTempControl Thermostatic Water Controllers
Thermostatic Water Controllers TempControl for the Precise and Accurate Control of Tempered or Hot Water Applications A necessity for all general uses and applications where the temperature of generated
More informationTechnical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE
Technical Data SD 4011 SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE A SERIES AIR ADJUSTED PILOT PRINTED IN U.S.A. SD 4011/9504 Type A or A83 (wt 6 lb) Type A53 or A 85
More informationSPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationThe BEST Plumbing Specialties. One Source. B 1 Quality, Durability, reliability
The BEST Plumbing Specialties. One Source. B 1 BraSS tubular Quality, Durability, reliability Since 1964 LYNCAR has manufactured and distributed high quality plumbing specialty items. In keeping with that
More informationHOSE BOXES. Includes hose boxes, supply boxes & hose valves MORRIS GROUP INTERNATIONAL
HOSE BOXES Includes hose boxes, supply boxes & hose valves MORRIS GROUP INTERNATIONAL INTEGRAL STOP NON-FREEZE WALL VALVE & BOX Integral Stop Wall Valve & Box with Non-freeze Protection Typical Applications
More informationBall Valves. Full Port Ball Valves - Compression w/ Drain Cap - Forged Brass. Full Port Mini Ball Valve - Forged Brass 05/06/15
05/06/15 G8 Full Port - Compression w/ Drain Cap - Forged Brass Rated for cold water, oil & gas Blow-out proof stem Temperature Range: -30 to 150C (-22 to 302F) Working Pressure: 600 psi Blue handle Lead-Free
More informationAIR SHOWER & TUB REP
SHOWER & TUB REPAIR 02-2091 Price Pfister, Ball Joint, O-Ring, 403927 For Shower Head. 03-1251 403954 Fiberglass Shower Drain, Fits 2 Cast Iron, Steel, ABS, or PVC, Seals With Compression Gasket. 02-3027
More informationEPP El Paso Plumbing, Inc. 140 W. 29 th. St. #347 Pueblo CO (719) FAX
EPP El Paso Plumbing, Inc. 140 W. 29 th. St. #347 Pueblo CO 81008 (719) 391-1676 FAX 385-0267 US AIR FORCE ACADEMY GOLF COURSE CLUB HOUSE PLUMBING PIPING SYSTEMS 22 42 23 COMMERCIAL SHOWERS, RECEPTORS
More informationSPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347
More informationMIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS
MIDDLESEX COUNTY COLLEGE EDISON, NJ 08818 LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS The College is soliciting bids to award a Local Supplier Blanket Order agreement for the purchase of supplies for the
More informationSTUDIO S BATH ACCESSORIES TOWEL BARS
STUDIO S BATH ACCESSORIES TOWEL BARS MODEL NUMBER: 7105.018-18" Towel Bar 7105.024-24" Towel Bar Available Finishes 002 Polished Chrome 295 PVD Brushed Nickel 2" 2" 3-7/8" (99 mm) 18" (457 mm) 2" 2" 3-7/8"
More informationFord Brass Saddles Style 101B and 202B
101B Ford Brass Saddles 101B and 202B 101B, 3/4" and 1" Taps 202B, 3/4" through 2" Taps Specifications Body - 85-5-5-5 brass alloy as per ASTM B62, ASTM B584 and AW WA C800. Threads may be FIP, AW WA,
More informationAquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003
Z6000 Series Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending Z6000 ADA Z6003 Exposed Closet/Urinal Systems Z6000 Z6001 Z6003 Z6010 Z6014 Z6017 Z6096
More informationPROJECT CATALOG 01 17
PROJECT CATALOG 01 17 FINISH AND PRICING GROUP CHART Standard Finishes Usually ships in 3-10 days Price Group I Price Group II Polished Chrome 07 Satin Nickel 12 Oil Rubbed Bronze Special Finishes Price
More informationInstallation Instructions
Installation Instructions for -/" Top Spud Fixtures MODEL NUMBERS 607 Series 707 Series OPERATING PRESSURE: Overall Range: 0- psi ** Recommended: psi (flowing) - 80 psi (static) FLOW REQUIREMENT: gpm (9.6
More informationSee Water Gauge/Liquid Level Catalog (PHBRWGA) for more detailed information about the products in this section.
See Water Gauge/Liquid Level Catalog (PHBRWGA) for more detailed information about the products in this section. water gauges 20-100 Series light Pattern Bronze Water Gauges LEAD FREE OPTION COMING SOON!
More informationInstallation Instructions Series Series
PORTSMOUTH Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found onlyon American Standard faucets. Recommended
More informationCATALOGUE Valves ~ Faucets ~ Specialties ~ Fittings & Nipples
CATALOGUE 2015 Valves ~ Faucets ~ Specialties ~ Fittings & Nipples CATALOGUE SECTIONS Click to go to section Pages 1-1 to 1-16 Pages 2-1 to 2-10 Pages 3-1 to 3-30 Pages 4-1 to 4-28 Part Number Numerical
More informationSECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING
SECTION 22 05 23 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Valves, General 2. Gate Valves 3. Balancing Valves 4. Ball Valves 5. Swing Check Valves 6. Backflow Prevention Assemblies 7. Pressure
More informationRigid/Swivel Optional Spouts
Rigid/Swivel Optional Spouts SPECIFYING PROCEDURE FOR OPTION RIGID/SWIVE SPOUTS: 1. Select BSE PRODUCT with Standard Gooseneck Spout, and with spout outlet and handles required. 2. Select Optional Rigid/Swivel
More informationInstallation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain
Installation Instructions JASMINE 80. Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed
More informationFord Service Saddles and Tapping Sleeves
DQS Inc. Section AA 09/2017 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001:2015 10004466 Ford Service Saddles and Tapping Sleeves Contents Recommended Product Application *Steel *C900/909*** Cast
More informationInstallation Instructions
Spread Lavatory Faucet with the Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
More informationMOEN FULL LINE 2008 ADDENDUM INCLUDES LEVEL KITCHEN, SALORA, COLONNADE & OUTDOOR FAUCETS
MOEN FULL LINE 2008 ADDENDUM INCLUDES LEVEL KITCHEN, SALORA, COLONNADE & OUTDOOR FAUCETS EFFECTIVE FEBRUARY 1, 2008 TABLE OF CONTENTS This addendum contains new products and should be used in addition
More informationAquaflush. Z6100 Series Aquaflush Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6140
Z6100 Series Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending Z6140 Concealed Closet/Urinal Systems Z6140 Z6142 Z6143 Z6144 Z6150 Z6152 Z6154 Z6155
More informationTHE KEENEY MANUFACTURING COMPANY
Brass Tubular P Traps 1-8 Repair Traps 8-9 S Traps 9-11 Sink Traps 11-15 Bath Traps 15 Washing Machine Traps 16 J Bends 16-17 Sink Trap J Bends 17-18 Wall Bends 19 Floor Tubes 19 Center Outlet Continuous
More informationJones Stephens Corp. PlumBest LTConnections SECTION E - COMMERCIAL & RESIDENTIAL PLASTICS. Closet Flanges & Accessories
SCTION - COMMRCIAL & RSIDNTIAL PLASTICS Closet Flanges & Accessories... 180-184 Residential Drains... 185-194 LevelBest Drain & Cleanout System... 195-198 Commercial Drain Bases... 199-200 Commercial Spuds
More informationPVC Couplings. Brass Couplings BRASS COMPRESSION COUPLING 3 -LENGTH PVC COMPRESSION COUPLING BRASS COMPRESSION COUPLING 5 -LENGTH
& FITT Brass Couplings BRASS COMPRESSION COUPL 3 -LENGTH 46331 3/8 1/2 12 120 5.80 46332 1/2 3/4 12 120 7.38 46333 3/4 1 6 72 10.52 46334 1 1 1/4 6 60 13.44 46335 1 1/4 1 1/2 4 48 18.00 46336 1 1/2 4 36
More informationSPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationSPEAKMAN CPT SentinelPro Thermostatic/Pressure Balance Valve Trim FEATURES: AVAILABLE FINISHES: ADD SUFFIX TO MODEL # WARRANTY: SPECIFICATION
SentinelPro Thermostatic/Pressure Balance Valve Trim CPT-5000 FEATURES: Chrome plated brass (trim plate) Metal valve handle & index Works with Speakman thermostatic/pressure balance valve model CPV-5000
More informationSPEAKMAN. SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET
SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET DESCRIPTION The SEF-1800-CA Eyesaver faucet combines a gooseneck faucet with
More informationDWV PVC DWV Drain Waste Vent Fittings
STANDARDS & SPECIFICATIONS Standards provide greater assurance of product performance and consistency, and are available to assist design engineers in system specification. The most frequently referenced
More informationInstallation Instructions
COLONY/COLONY SOFT Bidet Faucet and Transfer Valve with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a feature found only on American Standard
More informationSUPERSEDES ABS-C0811/AUG.
ABS-C0612/R JUNE 2012 SUPERSEDES ABS-C0811/AUG. 2011 SANITARY TEE REDUCING TEE TEE - Left Side Inlet 600007 1 1/4" 0 62852 60000 5 50 4,800 15.41 600015 1 1/2" 0 62852 60001 2 90 2,880 8.27 600023 2"
More informationSECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY
SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure
More informationInstallation Instructions
TROPIC Spread Lavatory Faucet with EverClean Finish & SpeedConnect Drain Installation Instructions 708.80 Congratulations on purchasing your American Standard faucet with EverClean finish and Speed Connect
More informationCUSTOM COMBINATION AIR VALVE
INSTALLATION / OPERATION / MAINTENANCE CUSTOM COMBINATION AIR VALVE INTRODUCTION This manual will provide you with the information to properly install and maintain this valve to ensure a long service life.
More informationGeneral Plumbing Information
General Plumbing Information Recommended Supply Line Pressures Service & Rough-in Abbreviations Service Fitting Index Color Coding Gas...0.216 psi Air (Ordinary)...15 psi Air (Air Powered Stirrer Operation)...40
More informationInstallation Instructions
Installation Instructions MANUAL FLUSH VALVE with BEDPAN WASHER For Use with -/" Top Spud Toilets 607.860 (.6gpf) 607.80 (.8gpf) Certified to comply with: ASSE 07 CSA B. ADA Compliant 0 AS America, Inc.
More informationSEF Eyesaver Service Sink Faucet with Eyewash/Drench Hose EYEWASH FEATURES: FAUCET FEATURES: COMPLIANCE: OPTIONS: Add suffix to model #
SEF-9000 Eyesaver Service Sink Faucet with Eyewash/Drench Hose EYEWASH FEATURES: Eyewash is connected to Speakman SC-5811-RCP service sink faucet s cold water integral stop port supply 6 ft. stainless
More informationSECTION VALVES PART 1 -GENERAL
SECTION 1571 0 VALVES PART 3- EXECUTION General Shut-off Valves Balancing Valves Drain Valves RELATED WORK Section 15430- Plumbing Specialties Section 15450- Plumbing Equipment PART 1 -GENERAL SCOPE This
More informationNAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY
NAVAL NAVAL I.I. Code No. 0816176 Rev. 1 INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS Certified Made in the U.S.A Exposed Closet Flushometer 1-1/2" Top
More informationHenderson Engineers, Inc. SECTION GENERAL DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL REQUIREMENTS
SECTION 220523 - GENERAL DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL REQUIREMENTS 1.1 SUMMARY A. This Section includes general duty valves common to most plumbing piping systems. 1. Special purpose
More informationFord Service Saddles and Tapping Sleeves
Section AA 04/2013; web revision 02/2014 Ford Service Saddles and Tapping Sleeves The Ford Meter Box Company, Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260-563-3171
More informationCouplings: Flex, ProSeal & No-Hub Drains Test Caps & Plugs Cleanout Plugs Cover Plates
Flexible Couplings for DWV & Non-Pressure Transitions Transitions all types of DWV plastic, and cast iron. 300 series stainless steel clamps Flexibility - Sleeve is manufactured of molded natural and synthetic
More informationG1849 Eyewash, Deck Mounted, AutoFlow 90º Swing-Down
Eyewashes G1849 Eyewash, Deck Mounted, AutoFlow 90º Swing-Down G1849LH-L G1849LH G1849LH-R G1849L G1849 G1849R Model G1849LH-L Shown Application: AutoFlow eyewash for mounting on counter. Spray heads swing
More informationDCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers
Dual Check w/ Atmospheric Port DCAP Series DUAL CHECK WITH ATMOSPHERIC PORT BACKFLOW PREVENTER The Apollo DCAP Series Backflow Preventer is designed to protect residential and commercial water supply lines
More informationInnovation + Quality. Valves, controls + systems Balancing and Control Valves
Innovation + Quality Valves, controls + systems Balancing and Control Valves Cocon Q Pressure independent control valve Product specification Size: L1 L2 H1 H2 ½, ½ LF 2.75 3.9 2.0 1.9 ¾ LF 2.9 4.2 2.0
More informationEXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS
050-1 EXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS DESCRIPTION 2" 3" 4" 5" 6" 8" 10" 12" SH PIPE...(PER 5' LG) 157.26 191.24 229.95 385.68 379.55 566.58 1019.46 1356.09 SH PIPE...(10' LNGTH) 186.01 256.53
More informationFord Fabricated Steel Products
Ford Fabricated Steel Products Section N2 12/2000 The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487 Overseas
More informationEXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS
050-1 EXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS DESCRIPTION 2" 3" 4" 5" 6" 8" 10" 12" Sh Pipe...(Per 5' Lg) 164.20 215.30 240.20 423.40 396.60 591.99 1119.59 1489.39 Sh Pipe...(10' Lngth) 198.40 268.00
More informationInstallation Instructions
Installation Instructions MANUAL FLUSH VALVE,. GPF Exposed Flushometer for /" top spud Urinals Certified to comply with: ASSE 07 ANSI/ASME A.9. ADA Compliant 0 AS America, Inc. M9600 Rev.. MODEL NUMBERS
More informationSECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.
SECTION 23 05 23 GENERAL-DUTY VALVES FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section includes valves for building services piping. 1.2 REFERENCES A. AGA Z21.22 (American Gas Association) - Relief Valves
More informationABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS.
ABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS www.bow-group.com dimension item Ctn Skid list price dimension item Ctn Skid list price SANITARY TEE (Hub x Hub x Hub) 1 1/4" 600007
More informationVacuum Breakers. Brass Construction 3/4 MHT Outlet
Vacuum Breakers Brass Construction 3/4 MHT Outlet MASTER ITEM # DESCRIPTION INNER CAR- TON QTY CARTON QTY HPVVBRB 3/4 FHT x 3/4 MHT Rough Brass 20 200 HPVVBCP 3/4 FHT x 3/4 MHT Chrome Plated 20 200 1 Body
More informationSection - L. Antipollution devices
Section - Antipollution devices ANTIPOUTION DEVICES EXAMPE OF APPICATION 2 3 3 2 4 1 1 Backflow preventer unit. 2 Backflow preventers with unregulated pressure zone. 3 Anti siphon devices. 4 Anti siphon
More informationABS-C0219 FEB SUPERSEDES ABS-C0717R CSA B181.1 ABS DWV FITTINGS.
ABS-C0219 FEB. 2019 SUPERSEDES ABS-C0717R CSA B181.1 ABS DWV FITTINGS www.bow-group.com DIMENSION ITEM CTN SKID LIST PRICE DIMENSION ITEM CTN SKID LIST PRICE SANITARY TEE (Hub x Hub x Hub) 1 1/4" 600007
More informationSpecifications. MOEN 3/4 Thermostatic Vertical Spa
FAUCET Metal construction with various finishes identified by suffix Includes four single-function body sprays Includes 7 rainshower showerhead, arm and flange Includes four function hand shower with 69
More informationSECTIO N 15 Phone: (866) Fax: (888)
PVC FITTINGS SCHEDULE 40, 80, INSERT NYLON FITTINGS PVC & CPVC NIPPLES SECTIO N 15 www.cbsupplies.ca Phone: (866) 503-5523 Fax: (888) 562-2095 AGI@cbsupplies.ca PRODUCTS LIST SCHEDULE 40 PVC PRESSURE FITTINGS
More informationPRESSURE RELIEF VALVES AND ACCESSORIES FOR A WIDE RANGE OF COMMERCIAL AND INDUSTRIAL APPLICATIONS. safety and relief valve catalog
PRESSURE RELIEF VALVES AND ACCESSORIES FOR A WIDE RANGE OF COMMERCIAL AND INDUSTRIAL APPLICATIONS safety and relief valve catalog Table of Contents PRODUCTS Valve Selection Guide.......................................................................
More informationSECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.
SECTION 210500 - COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, valves, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS A. Section 099000
More informationEVERCONNECT TM. Table of Contents. No-Hub Pipe. Flexible. 7 Couplings. Pipe Caps. Heavy Weight. Test Plugs. Couplings. Shielded Transition
Table of Contents No-Hub Pipe Couplings Heavy Weight Couplings Shielded Transition Couplings 3 4 4 Flexible Pipe Caps Test Plugs Drain/Trap & Tubular Connectors 7 7 8 EVERCONNECT TM Flexible & Reducing
More informationAquaVantage AV Z6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual
AquaVantage AV Z6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual Patented and Patents Pending Z6140AV AquaVantage Concealed Closet/Urinal Systems Z6140AV
More informationThrough-The-Wall TTW 1,TTW 2 Energy Saver Models
RESIDENTIAL REPLACEMENT PARTS LIST Through-The-Wall TTW 1,TTW 2 Energy Saver Models (M1TW, M2TW, M4TW, M4XRTW) Includes Hydrojet Total Performance System Effective: July, 2011 ECO 7619 NOTE: BOTH MODEL
More informationFIP 2 Outlet Angle Valve 3/8" V1-AB M2-AB006 3/8 IPS Escutcheon. M2-AB008 1/2" IPS CP Escutcheon. Hose Bibb Celecon V2-AB /4"
Valves FIP Straight Stop CP V-AB2 3/8" OD /2" V-0R0C U.S. 3/8" OD 3/8" V-0R2C U.S. 3/8" OD /2" FIP 2 Outlet Angle Valve V-AB70 3/8" OD 3/8" OD /2" V-AB8-468 3/8" OD /4" OD /2" FIP Chrome Angle Stop V-AB7
More informationPL-0912-PLSPEC Plumbing Specialities
PL-0912-PLSPEC Plumbing Specialities s Effective September 1, 2012 62FCLV CAST BRASS CLOSET FLANGE - CHROME CLEVELAND CODE CLOSET FLANGE 13.83 1 50 CF-100 4" FOR LEAD 14.13 1 50 CF-200 4" X 3" DWV FOR
More informationInstallation Instructions
Installation Instructions for /" top spud Urinals Certified to comply with: ASSE 07 ANSI/ASME A.9. ADA Compliant 0 AS America, Inc. MODEL NUMBERS 0.0 FOR TOP SPUD APPLICATIONS CLOG RESISTANT Self-cleaning
More information2-Way/2 Position Valves
4 2-Way/2 Position Valves Two-way solenoid valves have one inlet and one outlet, and are used to permit and shut off fluid flow. Two Types of Operations Apply Normally Closed (NC) Fluid is shut off when
More informationProduct Bulletin No Laboratory Ball Valves
Product Bulletin No. 03-03 Laboratory Ball Valves Ten years ago, WaterSaver introduced the first ball valve designed specifically for use in scientific laboratories. The L4200 valve was intended as an
More informationPage Concealed Flush Valve (1976 on)
8T _ Series Concealed Flush Valve (16 on) 2 10 14 11 15 1 8 OSC. HANDLE 16 1 10 14 1 12 15 8 4 1 /8" PUSH BUTTON 16 5/8" PUSH BUTTON 5 " PUSH PLATE OUTLETS See Page 40 18 21 2 22 20 6 FOOT PEDAL REPAIR
More informationROUGH PLUMBING. premium industrial products
ROUGH PLUMBING premium industrial products PREMIUM QUALITY PLUMBING PRODUCTS AMRAM AFFILIATE BRANDS For years, Cambridge Resources has been a primary source of premium quality cable management, hose clamps,
More informationGuide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY
SECTION 23 21 16 - HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Air
More informationEXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS
050-1 EXTRA HEAVY CAST IRON SOIL PIPE & FITTINGS DESCRIPTION 2" 3" 4" 5" 6" 8" 10" 12" Sh Pipe...(Per 5' Lg) 164.20 215.30 240.20 423.40 396.60 591.99 1119.59 1489.39 Sh Pipe...(10' Lngth) 198.40 268.00
More informationT&S BRASS AND BRONZE WORKS, INC.
Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SM Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com " [5mm] Faucet [0mm] Deck Mounting Hole Detail
More informationSuction Guide & Flo-Trex Valve Series
Suction Guide & Flo-Trex Valve Series Pump Trim FILE NO: 6-1 DATE: August 2010 SUPERSEDES: 6-1 DATE: July 200 Series SG & FTV Suction Guides Designed for direct mounting on the suction flange of horizontal
More informationTABLE OF CONTENTS. Pipe Diameter Chart (Reference Only)..50 Extensions 38,40,42,44
TABLE OF CONTENTS Item Page Item Page ANSI/AWWA Compact & Full Body Pipe Fittings: Product Submittals and Installation: Mechanical & Flange Joint C153. 3-9 20U Protective Fusion Bonded Epoxy....5,5 Mechanical
More informationSIMPATICO SIMPATICO LARSEN SUPPLY CO., INC.
S IMPATICO OFFERING A FINE COLLECTION OF DECORATIVE "UPGRADES. Replacement trim for your kitchen, bar, and bathroom. So easy to use, professional installation is not necessary. Full range of accessories
More informationMATERIAL SPECIFICATIONS AND BID PROPOSAL SHEET
CATEGORY 1: STEEL COUPLINGS 0 ¾" Steel Couplings (Smith-Blair #411-0501-003) 20 1" Steel Couplings (Smith-Blair #411-013201-003) 20 1¼" Steel Couplings (Smith-Blair #411-016601-003) 20 2" Steel Couplings
More informationMercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.
SECTION 23 22 13 STEAM AND CONDENSATE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification