Manifold Nozzles, Threaded Ø Company. Products. Technology. Application

Size: px
Start display at page:

Download "Manifold Nozzles, Threaded Ø Company. Products. Technology. Application"

Transcription

1 eries 20 Hot 07 Runner 01 Nozzle Manifold Nozzles, readed Ø10-20 ompany roducts ecnology pplication

2 eries 20 Manifold nozzles, treaded, open / closed / valve gate roduct type èhot Runner Nozzle, (treaded) èutilizes eat pipe tecnology to ensure uniform temperature èatented seal tecnology èreplaceable treaded tips vailable wit ten ontrolled Vestige (V) tip options including valve gates for zero vestige applications. ee table at rigt. t 1 Illustrations simplified, scematically drawn and not to scale. vailable gating types èfull flow: V10 & V20 èone oint: V11, V11M, V21,V21M èvalve gate: VG12 & VG23 tapered gate VG12 & VG23 straigt gate L1 Z Major imensions (mm) Nozzle lengt Band eated eated 160- Nozzle flow bore Ø10-20 * Ø50(band), Ø65(elical) *1 Ø85(band), Ø70(elical) t Ø32 Full flow termal gate V-10 Gate:Ø2-Ø6 t:ø32 vailable tip styles for R16 20 Nozzles Gating of nozzle tip 5 one point termal gate V-11 Gate:Ø2-Ø4 t:ø32 7 Valve Gate VG-12 Gate:Ø3.9 t:ø32 17 Heating èvailable wit replaceable band or elical eaters and termocouples. If band eated, one band eater is required for operation but an installed spare may be provided if space allows. Witness Mark V-11M Gate:Ø4 t:ø32 9 VG-12 Gate:Ø5 t:ø32 18 V-20 Gate:Ø2-Ø6 t:ø32 11 V-21 Gate:Ø2-Ø4 t:ø32 13 VG-23 Gate:Ø3.9 t:ø32 19 pplication èuitable for all filled and unfilled materials No Witness Mark V-21M Gate:Ø4 t:ø32 15 VG-23 Gate:Ø5 t:ø page no. of related data seets ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 1 / 20 see te ynventive Hot Runner Guide.

3 eries 20 Heater Options, Band & Band Heater. èone eater required for operation. If mold tickness allows a spare band eater will be installed. è Minimum = 160 è Maximum = 380 è= 80 for single eater 145 for installed spare eater L1 = 48 ( ) = 122 ( ) Ø50 Illustrations simplified, scematically drawn and not to scale. Ø85 Ø10-20 * Wen te distance from te manifold center locator to te ot runner nozzle center line exceeds te Ø50 clearance ole must be increased to Ø55 and te Ø8 5 ole increased to Ø90. Wen using te V11M and V21M tip styles te Ø85 eater clearance ole dept increases eliminating te Ø50 clearance ole. ee pg. 9/20 and pg. 15/ Heater. èwen is greater tan 425 two eaters are required for operation. è Minimum = 160 è Maximum = è , = , = /2 L1= 0 ( 160-) = /2 ( 425- Wen te distance from te manifold center * locator to te ot runner nozzle center line exceeds te Ø65 clearance ole must be increased to Ø70. Ø65 Ø70 Ø ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 2 / 20 see te ynventive Hot Runner Guide.

4 eries 20 ut out in mould plate for nozzle and connections 1. ut out for te nozzle Lengt from back of cavity plate to Gate location General tolerances: urfaces: IN IO 2768-m ( ) 1 * drawn offset ** to all oter pocket surfaces 1.6 Ø85/90 Illustrations simplified, scematically drawn and not to scale. 80 (1 eater) 145 (spare eater) Values of te dimension can be found in te data seet for te selected nozzle type. break edge 4 H6 Band Heater Ø50/55 * 5 2. ut out for connections àelectrical power àtermocouple ± ** Ø70/ , O 425-, /2 4. ut out for te nozzle tip ) b) t H roug bore nozzle tip (V10,V11, V11M, VG12 and VG12 Blind bore nozzle tip (V20, V21, V21M VG23 & VG2 ip Ø Hot runner gate Ø Lengt code H6 Heater 4 Ø65/70 ± break edge epending on te selected nozzle type, different cut outs are required for te nozzle tip. e dimensions of te cut out for te nozzle tip used can be found in te nozzle data seet ** 1) pplies to valve gate nozzles ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 3 / 20 see te ynventive Hot Runner Guide.

5 istance From Locator R Maximum eries 20 Manifold integration 20 eries 20 manifold criteria: è20 manifold systems do not require preload because tey are treaded directly into te manifold. èe systems typically ave a clearance between te trust pads and mold plates in te cold condition. s te manifold eats and expands te trust pads make wit te plates. èrust pads are made of a low conductivity material and sould only be replaced wit an equivalent ynventive part. èxcessive wit te mold will cause eat sinks and affect system performance. ontact wit te mold must be limited to specified areas. H6 Ø12 18 Illustrations simplified, scematically drawn and not to scale. rail eigt 80 support pad preload cold èminimum rail eigt: 108 (termal gates) 120 (valve gates) center locator è = Rail eigt (termal gate) = 22 (Valve Gate) è Minimum (termal gates) = 10 èminimum (valve gates) = 22 H7 Ø30 Ø / èr is te radial distance from te manifold center locator to te manifold nozzle center line. èfor longer R dimensions consult wit ynventive. Variable escription op ir Gap Mold ept op lamp late 20 Maximum Radial istance From Nozzle enterline to enter Locator "R" èreaded nozzles line up wit te gate locations in te mould in te cold condition. s te manifold eats and expands te nozzles flex. e distance from te center locator (R) determines te amount of nozzle flex. e table to te rigt defines te maximum allowable distance from te nozzle to te center locator Nozzle Lengt ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 4 / 20 see te ynventive Hot Runner Guide.

6 Manifold nozzle, sliding fit, full flow 20 V10 General: èfilled and unfilled materials èasy orifice canges by straigt reaming èheat pipes for isotermal operation 1 Nozzle riteria: è Ø2-Ø6 è lengt - ee art èopen flow bore èatented seal 17.7 band eater 22 elical eater Ref Ø2-6 L1 Z Information regarding àtolerances and surfaces àsape and position tolerances àcut out for connections àgroove/bore for locking pin Ø32 H6 30 please see page 3 ut out in mould plate for nozzle and connections èr is te radial distance from te manifold center locator to te manifold nozzle center line. èfor longer R dimensions consult wit ynventive. 20 contour criteria: èwen gating on an angled mold contour te vestige eigt may be increased depending on te angle è is te increase in vestige eigt required to maintain a 1.6 wall, and/or 5 minimum. R Min ooling required àaround te nozzle tip àopposite to te nozzle tip e front of te nozzle Heater zones power tip must always be against plastic. (Watt) General tolerances according to IN IO 2768-m Heater tyle Min Max Heater Qty Watts/Volts Band W/240V W/240V (eac) xtension L θ<14 ; =0 =16Nθ L=3-(/2)*Nθ 14 <θ<27 ; =5.7Nθ+(1.6/Oθ)-3 =+(16Nθ) L=3+-(/2)*Nθ θ>27 ; =16(Nθ)-6.5 =32(Nθ)-6.5 L=3+-(/2)*Nθ θ 5 Min 1.6 Min ngled Mold ontour ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 5 / 20 see te ynventive Hot Runner Guide.

7 eries 20 V10 ed gates 20 V10 Illustrations simplified, scematically drawn and not to scale. 20 recessed gate mold contour criteria: èvalues in tables are for materials not aving glass fibers. onsult ynventive for vestige eigt wen using glass fillers. èed gates are used to reduce vestige eigt above te part surface or keep te vestige below te part surface. èfor most materials V10 vestige eigt is equal to orifice/2. If te vestige Ø orifice 2 orifice 2 5 Min 30 onical (recess dept) R30 5 Min perical (recess dept) ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 6 / 20 see te ynventive Hot Runner Guide.

8 eries 20, V11 Manifold nozzle, treaded, cone point 20 V11 1 General: èfilled and unfilled materials èmore eat in gate area for semi-crystalline materials èheat pipes for isotermal operation Nozzle riteria: è Ø2-Ø4 è lengt - ee art èatented seal 17.7 band eater 22 elical eater Ref L1 Information regarding Z àtolerances and surfaces àsape and position tolerances àcut out for connections àgroove/bore for locking pin èr is te radial distance from te manifold center locator to te manifold nozzle center line. Ø2-4 R Min land 160 Ø32 H please see page 3 ut out in mould plate for nozzle and connections ooling required àaround te nozzle tip àopposite to te nozzle tip e front of te nozzle Heater zones power tip must always be against plastic. (Watt) General tolerances according to IN IO 2768-m Heater tyle Min Max Heater Qty Watts/Volts 20 contour criteria: èwen gating on an angled mold contour te vestige eigt may be increased depending on te angle è is te increase in vestige eigt required to maintain a land, 1.6 wall, and/or 5 minimum Band W/240V W/240V (eac) xtension 0.08 Land 3 L θ<16 ; =(/2)*Nθ =((32+)/2)*Nθ L= 16 <θ<27 ; =5.7Nθ+(1.6/Oθ)+(-2/2)-3 =+(16Nθ) L=+-(/2)*Nθ θ>27 ; =((30+)/2)*(Nθ)-6.5 =+16Nθ L=+-(/2)*Nθ θ 5 Min 1.6 Min ngled Mold ontour ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 7 / 20 see te ynventive Hot Runner Guide.

9 eries 20 V11 ed gates 20 V11 Illustrations simplified, scematically drawn and not to scale. 20 recess criteria: èvalues in tables are for materials not aving glass fibers. onsult ynventive for vestige eigt wen using glass fillers èed gates are used to reduce vestige eigt above te part surface or keep te vestige below te part surface Ø17 3 onical Lengt code (recess dept) Min 30 5 Min d R30 3Land d ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. H d / 20 perical see te ynventive Hot Runner Guide.

10 eries 20, V11M Manifold nozzle, treaded, cone point 20 V11M 1 General: èfilled and unfilled materials èeveloped for and B materials. èheat pipes for isotermal operation èe front face of te tip must be in wit plastic. èooling is required in te gate area. Nozzle riteria: è Ø4 è lengt - ee art èatented seal band eater 22 elical eater Ref Information regarding àtolerances and surfaces àsape and position tolerances àcut out for connections àgroove/bore for locking pin Z èr is te radial distance from te manifold center locator to te manifold nozzle center line. Ø4 R Min Ø32 H land please see page 3 ut out in mould plate for nozzle and connections ooling required Heater àaround zones te power nozzle tip(watt) àopposite to te nozzle tip e front of te nozzle tip must always be against plastic. General tolerances according to IN IO 2768-m Heater tyle Min Max Heater Qty Watts/Volts 20 contour criteria: èwen gating onto an angled mold contour te vestige eigt may be increased depending on te angle è is te increase in vestige eigt required to maintain a land, 1.6 wall and/or 5 minimum. Band Band (tip) W/240V W/240V W/240V (eac) xtension L θ<16 ; =(/2)*Nθ =((32+)/2)*Nθ L= 16 <θ<27 ; =5.7Nθ+(1.6/Oθ)+(-2/2)-3 =+(16Nθ) L=+-(/2)*Nθ θ>27 ; =((30+)/2)*(Nθ)-6.5 =+16Nθ L=+-(/2)*Nθ 5 Min θ 1.6 Min ngled Mold ontour ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 9 / 20 see te ynventive Hot Runner Guide.

11 eries 20 V11M ed gates 20 V11M Illustrations simplified, scematically drawn and not to scale. 20 recess criteria: èvalues in tables are for materials not aving glass fibers. onsult ynventive for vestige eigt wen using glass fillers èed gates are used to reduce vestige eigt above te part surface or keep te vestige below te part surface Ø17 orifice 5 Min 30 onical Lengt 4.0 code 1.59 (recess dept) d Ø2-4 R30 5 Min perical d ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 10 / 20 see te ynventive Hot Runner Guide.

12 eries 20 V20 Manifold nozzle, treaded, full flow 20 V20 1 General: èfilled and unfilled materials. èasy orifice size canges by straigt reaming. èheat pipes for isotermal operation èno witness mark on part èopen flow bore èasier removal of frozen material around tip for color cange. èooling is required in te gate area. Nozzle riteria: è Ø2-Ø6 è lengt (see cart) èopen flow bore èatented seal H6 Ø32 Ø21.3 Ø16.9 Ø11.4 Ø L band eater 27.7 elical eater Ref Information regarding àtolerances and surfaces àsape and position tolerances àcut out for connections àgroove/bore for locking pin please see page 3 Z ut out in mould plate for nozzle and connections èr is te radial distance from te manifold center locator to te manifold nozzle center line. èfor longer R dimensions consult wit ynventive. R Min 160 R1.5 R ooling required àaround te nozzle tip àopposite to te nozzle tip e front of te nozzle tip must always be against plastic. General tolerances according to IN IO 2768-m Heater tyle Min Max Heater Qty Watts/Volts Band W/240V W/240V (eac) 20 angled mould contour criteria: èwen gating on an angled mold contour, te vestige eigt may be increased depending on te angle. è is te increase in vestige eigt required to maintain a 1.6 wall and/or 4 L θ<11 ; =0 L=3-(/2)*Nθ 11 <θ<30 ; =5.7Nθ+(1.6/Oθ)-3 L=3+-(/2)*Nθ θ>30 ; =16Nθ+(4/Oθ)-10.1 L=3+-(/2)*Nθ θ 1.6 Min 4 Min ngled Mold ontour ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 11 / 20 see te ynventive Hot Runner Guide.

13 eries 20 V20 ed gates 20 V20, ed Illustrations simplified, scematically drawn and not to scale. 20 recessed mould contour criteria: èvalues in tables are for materials not aving glass fibers. onsult ynventive for vestige eigt wen using glass fillers èed gates are used to reduce vestige eigt above te part surface or keep te vestige below te part surface èfor most materials V20 vestige eigt is equal to 3 + (Ø /2). If te vestige eigt relative to te possible gate recess dept () is too great, use of a V11 tip is recommended. Ø orifice 2 orifice 2 30 onical Lengt code (recess dept) R30 perical (recess dept) ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 12 / 20 see te ynventive Hot Runner Guide.

14 eries 20, V21 Manifold nozzle, treaded, cone point 20 V21 1 General: èfilled and unfilled materials èno tip witness mark on part èmore eat in gate area for semi-crystalline materials èheat pipes for isotermal operation èasier removal of frozen material around tip for color cange Nozzle riteria: è Ø2.4 è lengt - ee art èatented seal 27.7 band eater 23.4 elical eater Ref Ø21.3 Ø16.9 Ø L1 Information regarding àtolerances and surfaces àsape and position tolerances àcut out for connections àgroove/bore for locking pin Z èr is te radial distance from te manifold center locator to te manifold nozzle center line. Ø2-4 R Min land 160 H6 Ø R1.5 R please see page 3 ut out in mould plate for nozzle and connections ooling required àaround te nozzle tip àopposite to te nozzle tip e front of te nozzle tip must always be against plastic. General tolerances according to IN IO 2768-m Heater tyle Min Max Heater Qty Watts/Volts 20 contour criteria: èwen gating on an angled mold contour te vestige eigt may be increased depending on te angle è is te increase in vestige eigt required to maintain land, 1.6 wall and/or 4 minimum wall tickness Band W/240V W/240V (eac) 0.08 Land L 3 θ<16 ; =(/2)*Nθ L= 16 <θ<30 ; =5.7Nθ+(1.6/Oθ)+(-2/2)* Nθ-3 L=+-(/2)*Nθ θ>30 ; =16Nθ+(4/Oθ)-10.1 L=+-(/2)*Nθ θ 1.6 Min 4 Min ngled Mold ontour ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 13 / 20 see te ynventive Hot Runner Guide.

15 eries 20 V21 ed gates 20 V21 Illustrations simplified, scematically drawn and not to scale. 20 recess criteria: èvalues in tables are for materials not aving glass fibers. onsult ynventive for vestige eigt wen using glass fillers èed gates are used to reduce vestige eigt above te part surface or keep te vestige below te part surface èmaintain land wen macining gate recess or contour. Ø17 30 onical Lengt code (recess dept) d R30 d ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. d / 20 perical see te ynventive Hot Runner Guide.

16 eries 20, V21M Manifold nozzle, treaded, cone point 20 V21M 1 General: èfilled and unfilled materials èno tip witness mark on part èeveloped for and B materials. èheat pipes for isotermal operation èasier removal of frozen material around tip for color cange èooling is required in te gate area. Nozzle riteria: è Ø4 è lengt - ee art èatented seal 33.5 band eater 27.7 elical eater Ref Ø21.3 Ø16.9 Ø Information regarding àtolerances and surfaces àsape and position tolerances àcut out for connections àgroove/bore for locking pin Z H6 please see page 3 èr is te radial distance from te manifold center locator to te manifold nozzle center line. Ø4 R Min land 160 Ø R1.5 R ut out in mould plate for nozzle and connections ooling required àaround te nozzle tip àopposite to te nozzle tip e front of te nozzle tip must always be against plastic. General tolerances according to IN IO 2768-m Heater tyle Min Max Heater Qty Watts/Volts 20 contour criteria: èwen gating on an angled mold contour te vestige eigt may be increased depending on te angle è is te increase in vestige eigt required to maintain land, 1.6 wall and/or 4 minimum wall tickness Band W/240V W/240V (eac) 0.08 Land L 3 θ<16 ; =(/2)*Nθ L= 16 <θ<30 ; =5.7Nθ+(1.6/Oθ)+(-2/2)* Nθ-3 L=+-(/2)*Nθ θ>30 ; =16Nθ+(4/Oθ)-10.1 L=+-(/2)*Nθ θ 1.6 Min 4 Min ngled Mold ontour ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 15 / 20 see te ynventive Hot Runner Guide.

17 eries 20 V21M ed gates 20 V21M Illustrations simplified, scematically drawn and not to scale. 20 recess criteria: èvalues in tables are for materials not aving glass fibers. onsult ynventive for vestige eigt wen using glass fillers èed gates are used to reduce vestige eigt above te part surface or keep te vestige below te part surface èmaintain land wen macining gate recess or contour. Ø17 30 onical Lengt 4.0 code 1.59 (recess dept) d R30 perical d ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 16/ 20 see te ynventive Hot Runner Guide.

18 20 VG12, apered eries 20 VG12 apered Manifold nozzle, treaded, valve gate 1 Illustrations simplified, scematically drawn and not to scale. General: èfilled and unfilled materials èapered valve pin to eliminate gate flas èheat pipes for isotermal operation Nozzle riteria: è Ø3.9 è lengt (see cart) èatented seal 17.7 band eater 22 elical eater Ref 2 Land Ø3.9 L1 Z Information regarding àtolerances and surfaces àsape and position tolerances àcut out for connections àgroove/bore for locking pin Ø32 H6 30 please see page 3 ut out in mould plate for nozzle and connections èr is te radial distance from te manifold center locator to te manifold nozzle center line. èfor longer R dimensions consult wit ynventive. R Min Land ooling required àaround te nozzle tip àopposite to te nozzle tip e front of te nozzle Heater zones power tip must always be against plastic. (Watt) General tolerances according to IN IO 2768-m Heater tyle Min Max Heater Qty Watts/Volts 20 VG12 angled mold criteria: èwen gating on an angled mold contour te vestige eigt may be increased depending on te angle è is te increase in orifice land required to maintain a 1.6 minimum wall tickness and/or 5 minimum θ<4 ; =0 =16Nθ 4 <θ<27 ; =5.7Nθ+(1.6/Oθ)-2 =+16Nθ θ>27 ; =16Nθ-6 =+32Nθ-6 Maximum θ = 32 Band W/240V W/240V (eac) xtension Ø3.9 θ 5 Min 1.6 Min 2 Land 15 ngled Mold ontour ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 17 / 20 see te ynventive Hot Runner Guide.

19 eries 20 VG12 traigt Manifold nozzle, treaded, valve gate 20 VG12, traigt 1 General: èfilled and unfilled materials èheat pipes for isotermal operation ètraigt valve pin in gate for nonadjustable actuators and glass filled materials. Nozzle riteria: è Ø5 è lengt (see cart) èatented seal 17.7 band eater 22 elical eater Ref 2 Land Ø5.000 Ø5.010 L1 Information regarding àtolerances and surfaces àsape and position tolerances àcut out for connections àgroove/bore for locking pin Z Heater zones Ø32 H6 30 please see page 3 Heater ut zones out in power mould plate (Watt) for nozzle and connections èr is te radial distance from te manifold center locator to te manifold nozzle center line. èfor longer R dimensions, consult wit ynventive R Min ooling required àaround te nozzle tip àopposite to te nozzle tip e front of te nozzle Heater zones power tip must always be against plastic. (Watt) 220 General tolerances according to IN IO 2768-m Heater tyle Min Max Heater Qty Watts/Volts 20 VG12 contour criteria: èwen gating on an angled mold contour te vestige eigt may be increased depending on te angle è is te increase in vestige eigt required to maintain a 1.6 minimum wall tickness and/or 5 minimum. Band W/240V W/240V (eac) xtension 2 Land θ<4 ; =0 =16Nθ 4 <θ<27 ; =5.7Nθ+(1.6/Oθ)-2 =+16Nθ θ>27 ; =16Nθ-6 =+32Nθ-6 θ 5 Min 1.6 Min ngled Mold ontour 18 / 20

20 eries 20 VG23 apered Manifold nozzle, treaded, valve gate 20 VG23,apered 1 General: èfilled and unfilled materials èno tip witness mark on part. èheat pipes for isotermal operation èapered valve pin to eliminate gate flas. Nozzle riteria: è Ø3.9 è lengt (see cart) èatented seal 22.4 band eater 26.7 elical eater Ref 2 Land L1 Z Information regarding Ø21.3 Ø16.9 Ø11.4 Ø àtolerances and surfaces àsape and position tolerances àcut out for connections àgroove/bore for locking pin H6 Ø32 please see page 3 ut out in mould plate for nozzle and connections èr is te radial distance from te manifold center locator to te manifold nozzle center line. R Min R1.5 R ooling required àaround te nozzle tip àopposite to te nozzle tip e front of te nozzle Heater zones power tip must always be against plastic. (Watt) General tolerances according to IN IO 2768-m Heater tyle Min Max Heater Qty Watts/Volts 24 VG23 contour criteria: èwen gating on an angled mold contour te vestige eigt may be increased depending on te angle è is te increase in land required to maintain a 1.6 minimum wall tickness and/or 4 minimum. Band W/240V W/240V (eac) Ø3.9 2 Land θ<4 ; =0 4 <θ<24 ; =5.7Nθ+(1.6/Oθ)-2 θ>24 ; =16Nθ-6+(4/Oθ)-9.1 θ 15 Maximum θ = Min 4 Min ngled Mold ontour ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 19 / 20 see te ynventive Hot Runner Guide.

21 eries 20 VG23 traigt Manifold nozzle, treaded, valve gate 20 VG23, traigt 1 Illustrations simplified, scematically drawn and not to scale. General: èfilled and unfilled materials èno tip witness mark on part. ètraigt valve pin for non-adjustable actuators and glass filled materials. èheat pipes for isotermal operation Nozzle riteria: è Ø5 è lengt (see cart) èatented seal 22.4 band eater 26.7 elical eater Ref 2 Land Ø21.3 Ø16.9 Ø L1 Z Information regarding àtolerances and surfaces àsape and position tolerances àcut out for connections àgroove/bore for locking pin H6 Ø32 please see page 3 ut out in mould plate for nozzle and connections èr is te radial distance from te manifold center locator to te manifold nozzle center line. Ø5.000 Ø5.010 R Min R1.5 R ooling required àaround te nozzle tip àopposite to te nozzle tip e front of te nozzle Heater zones power tip must always be against plastic. (Watt) General tolerances according to IN IO 2768-m Heater tyle Min Max Heater Qty Watts/Volts 24 VG23 angled mold criteria: èwen gating on an angled mold contour te vestige eigt may be increased depending on te angle è is te increase in land required to maintain a 1.6 minimum wall tickness and/or 4 minimum. Band W/240V W/240V (eac) 2 Land θ<4 ; =0 4 <θ<24 ; =5.7Nθ+(1.6/Oθ)-2 θ>24 ; =16Nθ-6+(4/Oθ)-9.1 θ 15 Maximum θ = ll rigts reserved. rrors and omissions excepted. For a specific application, please consult ynventive. 20 / Min 4 Min ngled Mold ontour see te ynventive Hot Runner Guide.

22 U - ustralia diepro@optusnet.com.au BR - Brasil - Brazil +55 (0) synventive@uol.com.br - anada N - eople's Republic of ina lutek@lutek.ca amed@dccnet.com inforcn@synventive.com Z - zec Rebpublic inforcz@synventive.com - Germany +49 (0) inforde@synventive.com - enmark inforsc@synventive.com - pain infores@synventive.com FI - Finland +358(0) cle@clegroup.fi FR - France +33 (0) inforfr@synventive.com GB - Great Britain +44 (0) inforuk@synventive.com IL - Israel adb2@barak.net.il IN - India inforin@synventive.com I - Italy inforit@synventive.com - apan jminamizono@synventive.com NL - e Neterlands +31 (0) infornl@synventive.com L - oland +48 (0) inforpl@synventive.com - ortugal inforp@synventive.com G - ingapore inforsg@synventive.com - lovak Republic +421 (0) inforsk@synventive.com U - United tates of merica info@synventive.com M-RM.BRM.GB-.IB

Manifold Nozzles, Sliding Fit Ø8-20. Company. Products. Technology. Application

Manifold Nozzles, Sliding Fit Ø8-20. Company. Products. Technology. Application eries R0 Hot 07 01 Runner Nozzle Manifold Nozzles, liding Fit Ø8-0 ompany roducts ecnology pplication roduct type eries R0 Manifold nozzles, sliding fit, open / closed / valve gate Hot runner nozzle, R

More information

Series GB N... S Single Nozzles, Valve Gate Ø16. Company. Products. A Application. T Technology

Series GB N... S Single Nozzles, Valve Gate Ø16. Company. Products. A Application. T Technology eries GB... ingle ozzles, Valve Gate Ø ompany roducts echnology pplication roduct type Hot runner nozzles in the GB... range; this series belongs to nozzle class. ozzle size : Flow boreø mm ozzle style

More information

Series 12 S01 V Single Nozzles, Valve Gate Ø12. P Products. C Company. T Technology. A Application

Series 12 S01 V Single Nozzles, Valve Gate Ø12. P Products. C Company. T Technology. A Application eries 1 ingle Nozzles, alve Gate ompany roducts echnology pplication eries 1 ingle nozzles, valve gate roduct type ot runner nozzles in the 1... range; this series belongs to nozzle class 1). ènozzle size

More information

C-Lube Linear Roller Way Super MX Linear Roller Way Super X

C-Lube Linear Roller Way Super MX Linear Roller Way Super X -Lube Linear Roller ay uper Linear Roller ay uper X 14 148 Aquamarine endplate for identification of -Lube Linear ay Identifi cation number and specifi cation Te specification of and series are identified

More information

C-Lube Linear Roller Way Super MX Linear Roller Way Super X

C-Lube Linear Roller Way Super MX Linear Roller Way Super X -ube inear Roller ay uper inear Roller ay uper X 14 Aquamarine endplate for identification of -ube inear ay Identifi cation number and specifi cation Te specification of -ube inear Roller ay uper is identified

More information

Pyxis & Corvus. Launch brochure

Pyxis & Corvus. Launch brochure Pyxis & Corvus Launc brocure Roblon Pyxis and Roblon Corvus downligts acieve uncompromising ligt quality tat is based on exceptional LED ligting tecnology. Pyxis and Corvus downligts are ideal for use

More information

KFD-HS. Power chucks with through-hole. Technical features:

KFD-HS. Power chucks with through-hole. Technical features: K-S ower cucks wit troug-ole ecnical features: Wedge ook system wit annular piston for igest accuracy in case of loss of centrifugal force bove-average mecanical efficiency Very few components, long jaw

More information

Hot Runner Manifold Series V-50 Catalog

Hot Runner Manifold Series V-50 Catalog U C ot unner Manifold Series V-50 Catalog 60 50 Stabilize your Process CA-02-0007_-ev04 06 / 2018 U U C ot unner 12 Manifold System Series Information V-50 ot unner System - Bolt Down Manifold Product

More information

Synventive Molding Solutions About us - in brief

Synventive Molding Solutions About us - in brief bout us - in brief ompany roducts echnology pplication bout us - in brief Dear Reader bout us could be: too detailed, too long or too much. In this time of information overload when we are often puzzled

More information

10.7 Single Valve Gate Nozzle GAN...S01

10.7 Single Valve Gate Nozzle GAN...S01 Single Valve Gate Nozzle GN...S01 10.7 Single Valve Gate Nozzle GN...S01 10.7.1 echnical Data - Single Valve Gate Nozzle GN...S01 Doc003429.png Single Valve Gate Nozzle Valve pin operation Operation medium

More information

Crossed Roller Slides

Crossed Roller Slides Crossed Roller Slides ov-crossed-slides-divider - Updated - 18-09-2017 165 Linear Linear Rail Sets Overview Standard cross roller rail sets L1000 & L1001 Seven rail profiles (Sizes 1-12) Lengts: 20mm to

More information

A VH Series. VH Series. AComparison with NSK standard products

A VH Series. VH Series. AComparison with NSK standard products 133-5-1.2 1. eatures (1) ig-performance end seals ig-performance end seals wit a multi-lip structure prevent te entry of various foreign matters. (2) lubrication unit (standard) Outstanding lubrication

More information

Series 09SVP Single Axis Valve Gate Nozzle

Series 09SVP Single Axis Valve Gate Nozzle Series 09SVP Single Axis Valve Gate Nozzle Stabilize your Process CAT-01-0065_EN-Rev03 EN 01 / 2018 Product Description - Technical Data NOTICE Valve Pin Operation Operation medium Pressure range Flowrate

More information

BERMAD Irrigation. Technical Specifications. WW-700 & 800 Series Metric. 800 Metric

BERMAD Irrigation. Technical Specifications. WW-700 & 800 Series Metric. 800 Metric Tecnical Specifications -700 & 0 Series SI 700 Metric SI 0 Metric Available Sizes & Patterns DN - DN 0 - Y Pattern DN - DN 4 - Angle DN 600 - DN 0 - Globe Connection Standard Flanged: ISO 7005-2 (ISO,

More information

EXCLUSIVELY AVAILABLE AT KAR IN CANADA

EXCLUSIVELY AVAILABLE AT KAR IN CANADA XLUSIVLY VILL T R I PS Series Universal - Plain ack ounting Semi-Steel ody, 3-aw Self-entering s wit 2-Piece ard Reversible aws edium duty 3 pinion design ac cuck is provided wit: 1 set of ard master jaws

More information

Series V-37 Hot Runner Manifold

Series V-37 Hot Runner Manifold H O R U N N E R E H N O L O G Y Series V-7 Hot Runner Manifold 6 7 Stabilize your rocess atalog Document -0-0005_EN-Rev0 EN 05/06 6 H7 Series V-7 Hot Runner Manifold roduct ype V-7 manifold for open flow

More information

Hot Sprue Bushings Products/Technical Guide

Hot Sprue Bushings Products/Technical Guide Hot Sprue Bushings Products/Technical Guide USB8 And SB8 Hot Sprue Bushings Notes 1. Cold bushing length must allow for thermal expansion to fit specified mold length. 2. For special "A" length order next

More information

Series V-42 Hot Runner Manifold

Series V-42 Hot Runner Manifold H O R U N N E R E H N O L O G Y Series V- Hot Runner Manifold 50 Stabilize your rocess atalog Document -0-000_EN-Rev0 EN 05/06 Series V- Hot Runner Manifold roduct ype V- manifold for open flow bore. Hot

More information

Grommets & Blanking plugs

Grommets & Blanking plugs Grommets & Blanking plugs mossexpress.co.uk GROMMETS, STRAIN RELIEF AN BLANKING PLUGS GROMMETS, STRAIN RELIEF AN BLANKING PLUGS New Pack Mounting Panel Hole EPM d H Qty Hole (d) Tickness 4980 49806 5.0.0.0

More information

A LH Series. LH Series A162. (2) Ball slide shape

A LH Series. LH Series A162. (2) Ball slide shape Series -5-1.3 Series (2) all slide sape all slide Model Sape/installation metod ig-load type ype Super-ig-load type 1 1 (1) eatures 1. ig self-aligning capability (rolling direction) Same as te D combination

More information

inst d u Building materials Approvals Qualities

inst d u Building materials Approvals Qualities No. Name 5 3 / 4 1 2 Material 1 Stud Zinc plated steel / A4 ( ) 2 Expansion sleeve A2 / A4 ( ) 3 Waser DIN 125A Zinc plated steel / A4 ( ) T inst t d fix f d u do SW l G No. Name l d nom ef Material 4

More information

NR/NRS. LM Guide B-93. A Technical Descriptions of the Products (Separate) B Product Specifications

NR/NRS. LM Guide B-93. A Technical Descriptions of the Products (Separate) B Product Specifications R/RS Guide Product Specifications Dimensional Drawing, Dimensional Table s R-R and R-R... s RS-R and RS-R... s R-A and R-A... s RS-A and RS-A... s R- and R-... s RS- and RS-... Standard engt and aximum

More information

Theory of turbo machinery / Turbomaskinernas teori. Chapter 4

Theory of turbo machinery / Turbomaskinernas teori. Chapter 4 Teory of turbo macinery / Turbomaskinernas teori Capter 4 Axial-flow turbines FIG. 4.1. Large low pressure steam turbine (Siemens) Axial-flow turbines FIG. 4.. Turbine module of a modern turbofan jet engine

More information

smart hot runner solutions

smart hot runner solutions Mould Design Recommendations for Hot Runner Applications smart hot runner solutions www.mastip.com Contents Mould Design Recommendations pg 3 4 5 6 6 6 8 9 11 12 13 Contents Introduction 1.0 Plate Requirements

More information

9.10 Valve Pin Height Adjustment QCVG Actuator

9.10 Valve Pin Height Adjustment QCVG Actuator 9.10 Valve in Height djustment QVG ctuator recondition for the following steps are to be performed with the QVG actuator installed in the mold, and the system at operating temperature. Heavy Weight Hazard

More information

MF-R Series - PTC Resettable Fuses

MF-R Series - PTC Resettable Fuses *RoHS OMPLINT & **HLOGN FR R0 780T Features n Radial Leaded evices n ured, flame retardant epoxy polymer insulating material meets UL 94V-0 requirements n RoHS compliant* and alogen free** n gency recognition:

More information

DURO-NC. Power chucks with quick-acting jaw change system. Technical features:

DURO-NC. Power chucks with quick-acting jaw change system. Technical features: K URO-NC Power cucks wit quick-acting jaw cange system Tecnical features: Central jaw unlocking for moving, canging and turning of jaws Hig workolding accuracy and gripping force Cucking power transmitted

More information

10.6 Single Valve Gate Nozzle 16S01_V

10.6 Single Valve Gate Nozzle 16S01_V Single Valve Gate Nozzle 16S01_V 10.6 Single Valve Gate Nozzle 16S01_V 10.6.1 echnical Data - Single Valve Gate Nozzle 16S01_V Doc003304.png Single Valve Gate Nozzle including ctuator HY2314S01 Valve pin

More information

LUJA POLE BASES WELL RING PRICE LIST 2015

LUJA POLE BASES WELL RING PRICE LIST 2015 LUJA BASES WELL RING PRICE LIST 2015 Non-binding, replaces te price list of 1 Dec 2013 fro 1 Dec 2014 1. LAMP POST BASES Te pole is ounted to te base using adjuster bolts. Rubber protectors are listed

More information

Quick Connectors DQ, DQM, and DF Series

Quick Connectors DQ, DQM, and DF Series Q, QM, and F Catalog No. QF-5 January 2012 No tools required to couple and uncouple. Bi-directional flow design. Versatile options of bot-end sutoff (V), single-end sutoff (SV), and bot end open (F ).

More information

A LH Series. LH Series. 2. Ball slide shape

A LH Series. LH Series. 2. Ball slide shape Series -5-1.1 Series are also available in randam matcing. (Special ig-carbon steel products for 15 to 45) 2. all slide sape all slide Model Sape/installation metod ype (Upper row, Rating: ower row, all

More information

A SH Series. SH Series. 2. Ball slide shape

A SH Series. SH Series. 2. Ball slide shape S Series -5-1.2 S Series 1. eatures (1) ower noise and gentler tone Incorporating a retaining piece and optimizing te circulation pat enables steel ball circulation stability and te prevention of ball

More information

MANN+HUMMEL Fuel filters

MANN+HUMMEL Fuel filters MANN+HUMML Fuel filters 65 Application areas for MANN+HUMML fuel filters Te rapid development of diesel tecnology as made te filtration of diesel fuel before it reaces te injection system a top priority.

More information

High Pressure Coolant Tool

High Pressure Coolant Tool 1/14 Hig Pressure Coolant Tool 2/14 Hig Pressure Coolant Tool Taegutec is pleased to introduce, T-BURST, a new tool older system or turning application tat is capale o delivering ig pressure coolant directly

More information

KFD-HE. Power chucks with through-hole

KFD-HE. Power chucks with through-hole K-HE Power cucks wit troug-ole Tecnical features: Rugged construction Large troug-ole Hig radial and axial true-running accuracy irect lubrication of all wearing surfaces Used in conjunction wit RÖHM actuating

More information

NSK Linear Guides. HA Series for Machine Tools

NSK Linear Guides. HA Series for Machine Tools NS inear Guides A Series for Macine ools Premier motion accuracy and rigidity innovative linear guide design, compatible wit ig precision macine tools Patent Pending Unparalleled motion accuracy, rigidity,

More information

ASSEMBLY GUIDE. D-M-E Tubular Manifold & Components System

ASSEMBLY GUIDE. D-M-E Tubular Manifold & Components System ASSEMBLY GUIDE D-M-E Tubular Manifold & Components System Customer Reference Information To our customers: D-M-E created this manual to assist you in the installation of our Tubular Manifold and Components

More information

8.15 Service of the Actuator VP4008P Series

8.15 Service of the Actuator VP4008P Series Service of the ctuator V4008 Series 8.15 Service of the ctuator V4008 Series 8.15.1 echnical Data V400801, V40080301 Doc003511.png o ensure long life and continued flawless operation of the actuator, we

More information

C-Lube Linear Way MH Linear Way H MH LWH

C-Lube Linear Way MH Linear Way H MH LWH -Lube Linear ay M Linear ay ML -Lube Maintenance ree Series -Lube Linear ay M M long term maintenance free supported! Te aquamarine end plate is te symbol of maintenance free. Identification umber and

More information

V-MV Variables Mooney Viskosimeter. Testing instruments. Laboratory Equipment. Software systems. Service. Consulting

V-MV Variables Mooney Viskosimeter. Testing instruments. Laboratory Equipment. Software systems. Service. Consulting V-MV 3 Testing instruments Laboratory Equipment Software systems Service Consulting Contents V-MV 3 Variable Mooney Viscosimeter according to ISO 289:25 / ASTM D 1646 DIN 53525 V-MV 3 - Sort overview 3

More information

Position Sensor Instruction Manual / Installation Guide

Position Sensor Instruction Manual / Installation Guide osition Sensor Instruction Manual / Installation Guide SV-07-0001_-Rev03 ompany echnology roducts pplication 08/ 2015 able of ontents 1 Service for the osition Sensor...3 1.1 ools for the osition Sensor

More information

RADLOK RADLOK FEATURES

RADLOK RADLOK FEATURES Rugged, Compact & Cost Effective ower Interconnect Solution Utilizing mpenol latest RDSOK tecnology, mpenol product line was designed wit compactness and robustness in mind. ower Interconnect products

More information

MVG25 Valve Gate.

MVG25 Valve Gate. www.mastip.com Assembly Overview System Overview Assembly Overview 1. IMPORTANT!! The back plate must be cooled and must not exceed 100 C. The cylinder should be in the closed position at all times except

More information

MVG40 Threaded Pin Valve Gate

MVG40 Threaded Pin Valve Gate MVG40 Threaded Pin Valve Gate www.mastip.com Assembly Overview System Overview Assembly Overview 1. IMPORTANT!! The back plate must be cooled and must not exceed 140 C. The cylinder should be in the closed

More information

High Pressure Coolant Tool

High Pressure Coolant Tool 1/14 Hig Pressure Coolant Tool 2/14 Hig Pressure Coolant Tool Taegutec is pleased to introduce, T-BURST, a new tool older system or turning application tat is capale o delivering ig pressure coolant directly

More information

KFD. Power chucks without through-hole. Technical features:

KFD. Power chucks without through-hole. Technical features: K Power cucks witout troug-ole Tecnical features: Proved power cuck wit ig load carrying capacity, long life and ig workolding accuracy Te operating power is transmitted by means of a sturdily dimensioned

More information

Optimized Radius of Roller Large End Face in Tapered Roller Bearings

Optimized Radius of Roller Large End Face in Tapered Roller Bearings NTN TECHNICAL REVIEW No.77 29 Tecnical Paper Optimized Radius of Roller Large End Face in Tapered Roller Bearings Hiroki FUJIWARA Takasi TSUJIMOTO Kazuto YAMAUCHI Tapered roller bearings can support eavy

More information

supertorc Actuators and Controls

supertorc Actuators and Controls supertorc Actuators and Controls Contents supertorc Actuators 4 5 6 7 7 7 8 8 8 Basic actuator Module system Scotc-Yoke principle Manual actuator Electric actuator Cylinder actuator Sub-sea actuator Spring

More information

Z Tube O.D. Slze. Min

Z Tube O.D. Slze. Min S Fittgs kok S Straigt Og Seal Fittgs are of positionable feature and provide connection tube to straigt tread boss. Furter tis as an advantage of elimatg weldg and brazg process wen used as bulkead fittg

More information

Hot Runner Guide Layout and Design

Hot Runner Guide Layout and Design H O T R U N N E R Layout and Design Stabilize your Process CAT-14-0001_EN-Rev05 EN 11/2017 T E C H N O L O G Y Layout and Design The purpose of this The - Layout and Design is intended to help everyone

More information

Nexus Pre-Wired Hot Runner System

Nexus Pre-Wired Hot Runner System Nexus Pre-Wired Hot Runner System www.mastip.com Overview Assembly Overview L Key Features Fast and simple installation out of the box Incorporates advanced heating technology for superior thermal performance

More information

STERILE CONTAINER SYSTEMS

STERILE CONTAINER SYSTEMS BASKET MADE FROM STAINLESS STEEL WIRE MESH WIRE BASKET WITH LID TK3-1010 TK3-1011 TK3-1012 TK3-1013 540 x 250 =35 mm 540 x 250 =55 mm 540 x 250 =75 mm 540 x 250 =105 mm TK3-1020 TK3-1021 TK3-1022 TK3-1023

More information

Power Clamp Cylinder

Power Clamp Cylinder ower lamp ylinder onforming to the ew S Standard Series Z2 ompliant ew Special /()U or rance ZR or urope ZT or orth merica Z2 2T/2/ () or sia 2 55 Toggle link mechanism aintains secure and powerful support.

More information

8.16 Service of the Actuator VP8016P Series

8.16 Service of the Actuator VP8016P Series Service of the ctuator V8016 Series 8.16 Service of the ctuator V8016 Series 8.16.1 echnical Data V80160501, V80160601, V80160801 Doc003489.png o ensure long life and continued flawless operation of the

More information

USAGE FOR HYDROSTATIC DRIVE APPLICATIONS GENERAL DEFINITIONS

USAGE FOR HYDROSTATIC DRIVE APPLICATIONS GENERAL DEFINITIONS UR... / Rev.NoDate eet No GENERL DEFINITION KG Vertical Hydrostatic plit aft PTO. Tis PTO Output as PTO Outputs and can Transmit Up To kw. It is Capable Up to KG t Hydrostatic Drive ode. It can provide

More information

FRANK. Technologies for the construction industry. Stabox & Coupler. Reinforcement connection & screw connection

FRANK. Technologies for the construction industry. Stabox & Coupler. Reinforcement connection & screw connection FRANK Tecnologies for te construction industry Stabox & Coupler Reinforcement connection & screw connection www.maxfrank.com Max Frank GmbH & Co. KG Mitterweg 1 94339 Leiblfi ng Pone +49 9427 189-0 Fax

More information

10.12 Sprue Bushing 12S Series

10.12 Sprue Bushing 12S Series 10.12 Sprue Bushing 12S Series lways tighten the screws to the torque specified in the respective table in section 13. Hazard of ressurized ir ressurized air blow can result in hot plastic or foreign bodies

More information

Mold Design. 7. Mold Design Runner & Gate. Bong-Kee Lee School of Mechanical Engineering Chonnam National University

Mold Design. 7. Mold Design Runner & Gate. Bong-Kee Lee School of Mechanical Engineering Chonnam National University 7. Runner & Gate Bong-Kee Lee Chonnam National University Delivery System Delivery System (Feed System) sprue (for a cold runner mold) cold slug well (for a cold runner mold) runner gate basic feed system

More information

Index 2. Safety information 2. Content 2. Technical 3. Specifications 3. Installation 4. Make sure all connectors are connected properly

Index 2. Safety information 2. Content 2. Technical 3. Specifications 3. Installation 4. Make sure all connectors are connected properly RGB 700 ma Wall Ceiling 360º 30º 10 cm 100 cm 172 gr 50.000 25º 40º 60º 120º 3 x Luxeon IP40 7 Watt Excluded CLS LUXO 3 RGB Manual Version 2.1 April 2017 DEX Index 2 Safety information 2 Content 2 Tecnical

More information

13. HYDRAULIC BRAKE SERVICE INFORMATION 13-1 XL200 BRAKE PAD/DISC 13-4 MASTER CYLINDER 13-6 BRAKE CALIPER 13-8

13. HYDRAULIC BRAKE SERVICE INFORMATION 13-1 XL200 BRAKE PAD/DISC 13-4 MASTER CYLINDER 13-6 BRAKE CALIPER 13-8 XL200 13. HYDRAULIC BRAKE SERVICE INFORMATION 13-1 TROUBLESHOOTING 13-2 BRAKE FLUID REPLACEMENT/ BLEEDING 13-3 BRAKE PAD/DISC 13-4 MASTER CYLINDER 13-6 BRAKE 13-8 SERVICE INFORMATION GENERAL t A contaminated

More information

INDEX CLS LUXO 3 RGB SAFETY INFORMATION CONTENT. Manual V2.3 - August Index 2. Luxo 3 ceiling units 4. Safety information 2

INDEX CLS LUXO 3 RGB SAFETY INFORMATION CONTENT. Manual V2.3 - August Index 2. Luxo 3 ceiling units 4. Safety information 2 DRIVER DRIVER EXCLUDED EXTERNAL Wall Ceiling 360º 30º 10 cm 100 cm 172 gr 50.000 40º 60º 120º 3 x Luxeon IP40 IP52 CLS LUXO 3 RGB Manual V2.3 - August 2018 DEX Index 2 Safety information 2 Content 2 Tecnical

More information

VERTICAL THRUSTER PNEUMATIC SLIDE

VERTICAL THRUSTER PNEUMATIC SLIDE ERTIAL TRUSTER PNEUMATI SLIDE Major Benefits Oversize guide rods Simple design Ideal for non-rotating applications Easy tooling mounting to tool plate bore sizes Units are powered by PD s rugged Series

More information

KFD-EC / KFD-F-EC. Power chucks without through-hole. Technical features:

KFD-EC / KFD-F-EC. Power chucks without through-hole. Technical features: Power cucks witout troug-ole K-EC / K--EC Tecnical features: Easy Care: low-maintenance and wear resistant Abrasionproof coating of te base jaw guidings Improofed dirt protection by integrated jaw guiding

More information

DEHA SPHERICAL HEAD LIFTING ANCHOR SYSTEM KKT 13-E

DEHA SPHERICAL HEAD LIFTING ANCHOR SYSTEM KKT 13-E KKT 13-E CONCRETE Tis catalogue is an installation and application instruction as defined in VDI/BV-BS 6205 Introduction Certified quality from HALFEN Connect to safety. VDI/BV-BS 6205 HALFEN Sperical

More information

100% 100% 100% RECYCLABLE CUSTOM DUTCH DESIGN

100% 100% 100% RECYCLABLE CUSTOM DUTCH DESIGN % DUTCH DESIGN Our stainless steel Superline planter is a classic for public areas, offices, airports an oter places were timeless esign an urable, low-maintenance solutions for interior an exterior plants

More information

TABLE 1 - PRODUCT FEATURES 2 1/16 2K,3K,5K 2 9/16 2K,3K,5K 3 1/8 2K,3K,5K 4 1/16 2K,3K,5K 5 1/8 2K,3K,5K -75 F (-60 C) THRU 250 F (121 C)

TABLE 1 - PRODUCT FEATURES 2 1/16 2K,3K,5K 2 9/16 2K,3K,5K 3 1/8 2K,3K,5K 4 1/16 2K,3K,5K 5 1/8 2K,3K,5K -75 F (-60 C) THRU 250 F (121 C) VALVES M SERIES OVERVIEW Te Valveworks USA M series consists of a lineup of gate valves wit reliable, proven designs tat are engineered and manufactured to meet te requirements of API 6A. Tis series of

More information

Power Clamp Cylinder

Power Clamp Cylinder ower lamp ylinder onforming to the ew S Standard Series Z2 ompliant ew Special /()U or rance ZR or urope ZT or orth merica Z2 2T/2/ () or sia 2 ourtesy of Steven ngineering, nc.-2 Ryan Way, South San rancisco,

More information

Linear Bushing LBE LBD LBB LM LME LMB

Linear Bushing LBE LBD LBB LM LME LMB Linear Busin LBLBLBBLMLMLMB Linear Busin is a i precision linear motion rollin uide wic travels alon a saft to acieve endless linear motion. In te external cylinder, a retainer, steel balls, etc. are compactly

More information

MANN+HUMMEL Filters for Liquids

MANN+HUMMEL Filters for Liquids MANN+HUMML Filters for Liquids MANN+HUMML Industrial Filters Te MANN+HUMML Group is an international company wit its eadquarters in Ludwigsburg, Germany. Te group employs approx. 9500 people worldwide

More information

Compatibility overview accessories for lathes

Compatibility overview accessories for lathes Compatibility overview accessories for lates Accessories items turning Item No TU 503 TU 2004 TU 2304 TU 2406 TU 2506 TU 2807 TU3008/V D 320 TU 3209 D 330 D 360 TU 360V D420 TU 420V TU 42 TU 420V TH 46

More information

Hot Runners and Temperature Controllers

Hot Runners and Temperature Controllers Hot Runners and Temperature Controllers Better parts, faster cycles Benefits Complete tooling solutions Application specific solutions Pristine gate quality Fastest cycles Fast color change Accurate, reliable

More information

NEW SIZE!! Low Profile Ball Type. EG Series. Linear Guideway. EG 35 Extend New Models

NEW SIZE!! Low Profile Ball Type. EG Series. Linear Guideway. EG 35 Extend New Models ow rofile all Type inear uideway Series Te four-row series is designed to offer ig load capacity and ig rigidity. It features equal load ratings in all four directions, and self-aligning capability to

More information

Classic & Threaded Nozzle Selection Guide...J4. Emerald Ceramic Technology...J8. Emerald Classic Nozzle...J6. Emerald Hot Runner Systems...

Classic & Threaded Nozzle Selection Guide...J4. Emerald Ceramic Technology...J8. Emerald Classic Nozzle...J6. Emerald Hot Runner Systems... J1 Classic & Threaded Nozzle Selection Guide...J4 Emerald Ceramic Technology...J8 Emerald Classic Nozzle...J6 Emerald Hot Runner Systems...J3 Emerald Threaded Nozzle...J7 Policosmetic Hot Runner Systems...J9

More information

Catálogo Asas, Punhos e Manetes

Catálogo Asas, Punhos e Manetes . Catálogo Asas, Punos e Manetes Loja: Av. Sacadura Cabral n.º37 A 1000-272 Lisboa el. 217940473 Fax 217969890 Escritório: Rua avid de Sousa n.º19 1000-105 Lisboa el.217906904 Fax 217906906 Bridge andles

More information

M Tube Fitting Design Standards & Codes

M Tube Fitting Design Standards & Codes 25 M Tube Fitting esign Standards & Codes Make-up 1 1/4 turns advance NUT by 1.25 pitces from finger-tigt position. n 20 TPI, 1.25 pitces travel 1/16 in. (1.5875 mm) make-up distance for Gaugeability M

More information

NEW. BERMAD Irrigation 100 Series - High Performance Valves. Water Control Solutions

NEW. BERMAD Irrigation 100 Series - High Performance Valves. Water Control Solutions NE BERMAD Irrigation ig Performance Valves ater Control Solutions 100 Series Yflow ig Performance Plastic ydraulic Control Valves Features and Benefits Durable industrial grade valve design and construction

More information

FDU HOT WATER COILS COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) DOWNSTREAM HEATING COIL OUT

FDU HOT WATER COILS COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) DOWNSTREAM HEATING COIL OUT COIL DISCARGE COLLAR FDU OT WATER COILS OPT. CAD SECTION COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) DISCARGE COLLAR COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) 3.500 (89) 6.500 (165) (SZ 10-40)

More information

KEEP IT LEVEL.

KEEP IT LEVEL. KEEP IT LEVEL Ideal for macinery and conveyor belts, our range of Pressed Bolt own Feet includes an asymmetrical base sape to improve clearance wen situating feet close to walls or walkways. For easy eigt

More information

CUSTOM INCEPTION SEAT SUPPORT SURFACE SHORT ORDER FORM

CUSTOM INCEPTION SEAT SUPPORT SURFACE SHORT ORDER FORM For best results, do not fill out in your browser. Interactive form should be completed using Adobe Reader after saving to your local drive. Then email to customs@comfortcompany.com or print and fax to

More information

INTEGRAL BONNET FORGED NEEDLE VALVES. VN5 Series.

INTEGRAL BONNET FORGED NEEDLE VALVES. VN5 Series. INTEGRA BONNET FORGED NEEDE VAVES VN5 Series www.uniok.com Vaves - VN5 Series Features ressure rating up to 5000psig (340bar) @38 C (00 F) Temperature rating from -53 C(-65 F) to 232 C (450 F) wit standard

More information

Evaluation of Turnability of Tracked Vehicle

Evaluation of Turnability of Tracked Vehicle JARQ 3, 249-253 1996) Evaluation of Turnability of Tracked Veicle Nobutaka ITO Department of Bioproduction and Macinery, Faculty of Bioresources, Mie University Tsu, Mie, 514 Japan) Abstract Rice combine

More information

P64F - Olympian Plus plug-in system Soft start/dump valves

P64F - Olympian Plus plug-in system Soft start/dump valves > Port size: /4... /4 (ISO G/PTF) > Solenoid, air pilot or manual operator > ssists machine designers in complying with the European Machineries Directive > High forward flow and capacity dump facility

More information

Self Contained Dual Shaft Body Less Valve Gate Nozzle System, Single Application

Self Contained Dual Shaft Body Less Valve Gate Nozzle System, Single Application DSB-500 Self Contained Dual Shaft Body Less Valve Gate Nozzle System, Single Application NOZZLE DESCRIPTION: The "DSB-500 Nozzle Assembly is furnished with a heated radius cap and locating ring (Ø3.990)

More information

8.5 Service of the Actuator PNC4508M02 Series

8.5 Service of the Actuator PNC4508M02 Series 8.5 Service of the ctuator N4508M02 Series 8.5.1 echnical Data N4508M02-F, N4508M02-R Doc003635.png Doc003653.png () (B) () LOSED O OOLING ctuator, bolted to manifold. Valve pin operation Operation medium

More information

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

B1-2. Table of Contents LOUVERED FACE DIFFUSERS 1 LOUVERED FACE DIFFUER Table of Contents LOUVERED FACE DIFFUER 12 1400, 1400FR, 1400, M1400 & M1400 These supply diffusers feature a round neck and four cones. 1400A & 1400A These supply diffusers feature

More information

Design and Performance Evaluation of an Air-Blast Atomizer

Design and Performance Evaluation of an Air-Blast Atomizer Design and Performance Evaluation of an Air-Blast Atomizer Dr. Olusegun Adefonabi Adefuye Department of Mecanical Engineering, Lagos State University, Lagos, Nigeria Bennet Ifenna Okoli Centre for Space

More information

Slide Bearings Type E For Shaft Diameter Range mm Main Application Field Electric Machines

Slide Bearings Type E For Shaft Diameter Range mm Main Application Field Electric Machines Slide Bearings Type E For Shaft Diameter Range 160-315 mm Main Application Field Electric Machines End flange mounted slide bearing type EFWF with water-cooling and lubrication by a fixed oil ring RENK

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Hot Runner Solutions for Technical Moulding. An Introduction to Mastip Technology.

Hot Runner Solutions for Technical Moulding. An Introduction to Mastip Technology. Hot Runner Solutions for Technical Moulding An Introduction to Mastip Technology www.mastip.com Company Profile Mastip is a leading supplier of innovative hot runner solutions to the global plastic injection

More information

System Selection Guide

System Selection Guide Your Complete Hot Runner Configuration Guide www.mastip.com We make things better 2 Contents Contents Standard Hot Runner Configuration Hot Runner System Overview Selection Overview zzle Range and Series

More information

Axial piston variable pump A10V(S)O Series 31

Axial piston variable pump A10V(S)O Series 31 Axial piston variable pump A10V()O eries 31 RE 92701 Edition: 06.2016 Replaces: 01.2012 ize 18 (A10VO) izes 28 to 1 (A10VO) Nominal pressure 280 bar Maximum pressure 350 bar Open circuit Features Variable

More information

FLOTAX FC 1. TABLE OF CONTENT FLOTAX FC. Installation & Maintenance Manual ATEX UNIT SHIPPED WITHOUT OIL

FLOTAX FC 1. TABLE OF CONTENT FLOTAX FC. Installation & Maintenance Manual ATEX UNIT SHIPPED WITHOUT OIL ATEX UNIT SHIPPED WITHOUT OIL 1. TABLE OF CONTENT 1. Table of content... 1 2. Scope... 2 3. Sipping... 2 4. Maintenance... 2 5. Installation... 2 5.1. Mounting position... 2 5.2. Torque arm assembly...

More information

2,300 4,266 / 5,605. pneumatic ,580 1,604 2,500 1,395 1,224. Some of the photos may include optional equipment.

2,300 4,266 / 5,605. pneumatic ,580 1,604 2,500 1,395 1,224. Some of the photos may include optional equipment. Dimension Specification Identification 1.1 Manufacturer Hyundai Hyundai Hyundai 1.2 Manufacturer s type designation 1.3 Drive: electric (attery or mains),diesel,petrol,fuel gas,manual DIESEL DIESEL DIESEL

More information

iteka design Mario Cucinella products.iguzzini.com/iteka_line x270 Le Albere - Trento, Italy

iteka design Mario Cucinella products.iguzzini.com/iteka_line x270 Le Albere - Trento, Italy design Mario Cucinella 6000 3500 195x270 e Albere - Trento, taly Arcitectural and ligting project: Renzo Piano Building Worksop Poto: Enrico Cano products.iguzzini.com/iteka_line 379 Features 03 P66 K09

More information

CUSTOM INCEPTION SEAT SUPPORT SURFACE SHORT ORDER FORM

CUSTOM INCEPTION SEAT SUPPORT SURFACE SHORT ORDER FORM For best results, do not fill out in your browser. Interactive form should be completed using Adobe Reader after saving to your local drive. Then email to customs@comfortcompany.com or print and fax to

More information

Machine shut-off nozzle for Elastomer; Type-E Integrated actuator and tempering system

Machine shut-off nozzle for Elastomer; Type-E Integrated actuator and tempering system Machine shut-off nozzle for Elastomer; Type-E Integrated actuator and tempering system Application: Elastomeric plastics Shut-off technique: Integrated two way pneumatic actuator Characteristics: Integrated

More information

TURBOVAC i Turbomolecular pumps

TURBOVAC i Turbomolecular pumps TURBOVAC i Turbomolecular pumps A giant leap in vacuum performance! It as never been so easy to improve your processes until now. TURBOVAC (T) 350-450 i will allow you to optimize pump down times and consistently

More information

ENPLA. Any question? Access to Premium nozzle series WINA ENPLA. Headquarters Plant Subsidiary Sales office Agency

ENPLA.  Any question? Access to  Premium nozzle series WINA ENPLA. Headquarters Plant Subsidiary Sales office Agency www.yudo.com Any question? Access to http://qna.yudo.com Netherlands UK France Portugal Germany Italy Spain Czech Egypt Finland Poland Slovakia Russia Romania Weihai Turkey Iran Qingdao Syria China Korea

More information

...vibration isolation. Miscellaneous Parts

...vibration isolation. Miscellaneous Parts ...vibration isolation Parts Anti-vibration Mounts engine l P2040 Rubber on silver zinc plated steel. Tecnical Notes Wit a bell-like base tis unit is suitable for supporting most applications, suc as engine

More information

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information