MCB s RCD s & FUSE HOLDERS

Size: px
Start display at page:

Download "MCB s RCD s & FUSE HOLDERS"

Transcription

1 MCB s RCD s & FUSE HOLDERS, 2 & 3 POLE CHARACTERISTICS B, C & D CURRENT RATINGS FROM 0.5 AMP TO 63 AMPS UP TO 0KA BREAKING CAPACITY ADD ON AUXILIARY CONTACTS 2 & 4 POLE RCD s RCD SENSITIVITY FROM 30mA TO 300mA 2 POLE COMBINED MCB/RCD s, 2 & 3 POLE DIN RAIL MOUNTED FUSE HOLDERS WIDE RANGE OF BUSBAR ALSO CONTACTORS, PUSHBUTTONS & SWITCHES Tel: Fax:

2 INDEX PAGE No. PAGE PAGE 2-4 PAGE 5 PAGE 6-8 PAGE 9 PAGE 0-2 PAGE 3 PAGE 4 PAGE 5-20 PRODUCT DESCRIPTION DIN RAIL MOUNTED FUSE HOLDERS MCB s, ISOLATORS, AND ADD ON AUXILIARY BLOCKS CONNECTING BUSBAR TWO AND FOUR POLE RCD s TWO POLE COMBINED MCB/RCD s 22.5mm IP65 PUSHBUTTONS, INDICATORS AND SWITCHES AMMETER AND VOLTMETER SELECTOR SWITCHES MINI CONTACTORS UP TO 4KW THREE AND FOUR POLE CONTACTORS, 4KW UP TO 450KW Due to constant product development, specifications are subject to change without notice

3 FUSE DISCONNECTORS DIN rail mounted,2 & 3 Pole For fuse links 0.3 x 38mm, max V AC Standards IEC 947- NFC 6 20 UNE 2 03 Advantages Materials resistant to high temperatures Silvered contact parts Low own heating Fixing to standard din rail of 35mm (EN50022) Connecting terminals to 6mm 2 Possibility of sealing in switched ON condition Degree of IP protection acc. to DIN is IP20 Category of application: AC 20 Dimensions 79 64,5 47, ,5 ETI 0X38 600v~ 8 Ordering Information Type Description No. Modules HSC 0 x 38- pole HSC 0 x pole 2 HSC 0 x pole 3

4 MINIATURE CIRCUIT BREAKERS, MCB S Characteristic B B - Characteristic TRIPPING TIME SECONDS MINUTES CLIPSAL MCB s are produced according to the latest European norm EN60898 and IEC898 for protection and control of circuits against overloads and short-circuit in domestic, commercial and industrial applications Characteristic B is recommended for domestic and commercial installations for lighting and heating. Thermal release at.3 to.45 x In. Magnetic breaking release at 3 to 5 In. Characteristic C is recommended for industrial applications where higher starting effects are expected e.g. transformers, motors and lighting installations. Thermal release at.3 to.45 x In. Magnetic breaking release at 5 to 0 x In. Characteristic D is recommended for heavy industrial applications where very high starting effects are expected, e.g. motors starting under load. Thermal release.3 to.45 x In. Magnetic breaking release 0 to 20 In. Specifications Voltage Ue: 230/400V 60V DC per pole Frequency: 50/60Hz Poles:, 2 and 3 poles Breaking capacity: Up to 32Amps 0KA 40Amps & above 6KA Ambient temperature: -25 to +40ºC Protection Class: IP20 Electrical Life: > operations Mechanical Life: > operations Terminal Sizes: All 25mm 2 Characteristic C TRIPPING TIME Characteristic D TRIPPING TIME SECONDS MINUTES SECONDS ,2,4,6,8 2 2, X RATED CURRENT C - Characteristic,2,4,6,8 2 2, X RATED CURRENT D - Characteristic X RATED CURRENT 2

5 MINIATURE CIRCUIT BREAKERS, MCB s Ordering Information SINGLE-POLE MCB s TWO-POLE MCB s THREE-POLE MCB s Order Current Breaking Code Rating Capacity B - CHARACTERISTIC TSB kA TSB-0 0 0kA TSB-6 6 0kA TSB kA TSB kA TSB kA TSB kA TSB kA TSB kA C - CHARACTERISTIC TSC-005 0,5 0kA TSC-0 0kA TSC kA TSC kA TSC kA TSC-0 0 0kA TSC-6 6 0kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA D - CHARACTERISTIC TSD-0 0kA TSD kA TSD kA TSD kA TSD-0 0 0kA TSD-6 6 0kA TSD kA TSD kA TSD kA Order Current Breaking Code Rating Capacity B - CHARACTERISTIC TSB kA TSB kA TSB kA TSB kA TSB kA TSB kA TSB kA TSB kA TSB kA C - CHARACTERISTIC TSC-20 0kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA D - CHARACTERISTIC TSD-20 0kA TSD kA TSD kA TSD kA TSD kA TSD kA TSD kA TSD kA TSD kA Order Current Breaking Code Rating Capacity B - CHARACTERISTIC TSB kA TSB kA TSB kA TSB kA TSB kA TSB kA TSB kA TSB kA TSB kA C - CHARACTERISTIC TSC-30 0kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA TSC kA D - CHARACTERISTIC TSD-30 0kA TSD kA TSD kA TSD kA TSD kA TSD kA TSD kA TSD kA TSD kA OPTIONAL TERMINAL COVERS ARE AVAILABLE ON REQUEST AT NO EXTRA CHARGE 3

6 ISOLATORS 2- pole isolators to be used as isolating switch in circuits as defined in the 6th.edition of the IEE Wiring Regulations (BS ). Specifications Rigid conductor: 50mm 2 Flexible conductor: 35mm 2 Mechancial life: operations Electrical life: > operations Breaking capacity: 25 kamps Modular width: 2 x 7.5mm Green/Red mechanical indication Dimensions ON ON Ordering Information TYPE TIS 200E DESCRIPTION Isolator 2x00Amps ADD ON AUXILIARY CONTACT BLOCK FOR MCB s Mechanical auxiliary contact for CLIPSAL MCB S. Excellent contact even with weak current. Specifications Voltage Ue: 230/400V Contacts: Max. 6 Amps at 230V AC or Amp at 0V DC Contact functions: breaking and making Width: /2 module (9mm) Ambient temperature: -25 to +40 degrees C Max terminal area:.5mm 2 Electrical life: > operations Dimensions Ordering Information 2 TYPE TPS-68 4

7 CONNECTING BUSBAR Pin Type Fork Type 7,5 7,5 GA- GA- Pin Type, 2 3 phase solid copper conductors with pin attachments for connection of NORM modular components e.g. MCB s and RCD s. Fork Type, 2 3 phase solid copper conductors with fork attachments for connection of NORM modular components e.g. MCB s and RCD s. Type Length mm Modules Area mm 2 Type Length mm Modules Area mm 2 Single Phase Single Phase S IL 000/ S IL 000/ G L 000/ G L 000/ Three Phase Three Phase S 3L 000/ S 3L 000/ G 3L 000/ G 3L 000/ END PROTECTOR FOR THREE-PHASE BAR GA- End protector END PROTECTOR FOR THREE-PHASE BAR GA- End protector 5

8 RESIDUAL CURRENT DEVICES (RCD S) CLIPSAL RCD s are designed to open automatically when an earth leakage fault occurs, the fault can either be between phase and earth and/or between neutral and earth. The fault shall be greater than the calibrated sensitivity of the respective RCD (0, 30, 00, 300 or 500mAmps). The RCD thereby prevents fires, electrolytic corrosion and loss of energy, as well as protecting human life. Specifications Electrical Life >0 000 operations Mechanical Life: > operations Ambient temperature: +40 to -25ºC Terminal Rigid Conductor: 25mm 2 Terminal Flexible Conductor: 25mm 2 Mechanical Switch Colour Indication The RCD works on the principle that the vector sum of all current consumption is zero. In the case of an earth fault, some of the current takes another path. The result is then less than zero, which is detected by the RCD, and when the difference is in excess of the calibrated difference the switch opens on all poles. Fig.. shows an appliance connected to earth. Under normal circumstances, when there is no fault in the circuit, the current between phase and neutral is as shown, and the body of the appliance is safe to human contact, since there is no current flowing through it. When an installation fault occurs in the appliance, the current path is altered radically as shown in Fig. 2. We now find that the current s normal path is partly through the appliance and partly through the person and the earth connection. The current intensity that passes through one of these paths is dependent on the voltage between the appliance and earth and the resistance in the human body. The combination of the intensity of the current and the time factor can cause a fatal accident. T(ms) A B The three main components in the RCD are: - The Core transformer which detects the fault. - The Relay which is the heart of the RCD is current-activated and inducts the transformer, which in its turn affects the mechanical action. - The Mechanism which opens and closes the contacts. Figure 3 (ma) eff.rms A current time diagram is defined in the norm CIE 479/74. This diagram is reproduced in Fig. 3 where also the characteristics of Clipsal RCD s for 0mAmps, and 30mAmps, are shown. A Sensitivity for 0mAmps B Sensitivity for 30mAmps Zone : Normally no effect. Zone 2: Normally no serious effect. Zone 3: Normally no risk for heart fibrillation. Zone 4: Possible risk for heart fibrillation (under 50%). Zone 5: Risk for heart fibrillation (over 50%) Generally the RCD s are sensitive to transient phenomena that occur in the following circumstances: - Where there are long cables with high capacitance connected to the earth. - As a result of thunder storms. - When there are other circuits with high voltage, arcs and high-peak values. These can cause nuisance tripping of the RCD with consequential damage. ALL CLIPSAL RCD s have transient protection which reduces these effects to a minimum. Produced according to BSEN

9 TWO-POLE RCD s RCD s for assembly on 35mm DIN-profile bar or for assembly in NORM enclosures. All types have nuisance-tripping protection. Equipped with double terminal clamps for both rigid and flexible conductors. Screw terminals height over DIN-profile bar is 30mm. Mechanical switch colour indication. EN 6008 APPROVED Specifications Voltage: 230/400V 50-60Hz Protection class: IP40 Breaking capacity: 0 kamps Ambient temperature: -25 to +40ºC Max.area flexible conductor: 25mm 2 Max.area rigid conductor: 25mm 2 Electrical life: >0 000 operations Size: 2 x 7.5mm Dimensions 42,4 Plastic Enclosures 2 N CT2 Dimensions 39 x 5 x 6mm Plastic enclosures complete with DIN-rail for NORM components. Protection class IP40. Strong construction. Material: Self-extinguishing ABS-plastic ,9 N 8 7,5 87, Ordering Information Type Rated Current Sensitivity mamps Amps CT2 T T T T T T T T T T T T T T T T mA sensitivity versions available to special order. 7

10 FOUR-POLE RCD s RCD s for assembly on 35mm DIN-profile bar or for assembly in NORM enclosures. All types have nuisance-tripping protection. Equipped with double terminal clamps for both rigid and flexible conductors. Screw terminals height over DIN-profile bar is 30mm. Mechanical switch colour indication. EN 6008 APPROVED Specifications Voltage: 230/400V 50-60Hz Protection class: IP40 Breaking capacity: 0 kamps Ambient temperature: -25 to +40ºC Max.area flexible conductor: 25mm 2 Max.area rigid conductor: 25mm 2 Electrical life: >0 000 operations Size: 2 x 7.5mm Dimensions Plastic Enclosures 42,4 CT4 Dimensions 39 x 88 x 6mm 2 N Plastic enclosures complete with DIN-rail for NORM components. Protection class IP40. Strong construction. Material: Self-extinguishing ABS-plastic ,9 8 N 7,5 87, Ordering Information CT4 Type Rated Current Sensitivity mamps Amps T T T T T T T T T T T T T T T mA sensitivity versions available to special order.

11 RCBO s-combined MCB/RCD TWO POLE Providing the combined advantage of protection against earth leakage faults with short-circuit protection. Modular width 2 x 7.5mm. EN 6009 APPROVED Specifications Voltage: 0/230V Breaking capacity: 4,5kAmps Sensitivity: 30mAmps. Ambient temperature: -25 to +40ºC N Dimensions TEST 0 30mA T RCBO N T Ordering Information Type Rated Current Characteristics Amps TCU6 6 C TCU0 0 C TCU6 6 C TCU20 20 C TCU25 25 C TCU32 32 C TCU40 40 C 9

12 22.5mm PUSHBUTTONS AND SWITCHES A robust, high quality range of pushbuttons, selector switches, key switches and emergency stop stations. All to IP65 protection rating. * Colour codes: = Black 2 = Red 3 = Green 4 = Yellow 5 = Blue 6 = White Specification Approvals: UL CSA SEV IMQ DEMDO SEMDO SETI Climatic: Mild climate (Din 5004) - 23/50 Conditions: Damp climate (Din 5005) -23/83 Hot damp climate (Din 5005) - 40/92 Variable damp climate (Din 5006) FW24 Temperature: Operating -25ºC to +70ºC Storage -40ºC to +70ºC Protection: IP65 to IEC 529, Din 40050, CEI 70- Insulation: Group C (VDE 00 - CEI 07- Class II (Double insulation CEI 23-, CEE 24, IEC 536) Ratings: Insulation voltage 600 VAC/DC to CSA 22.2 No 4, UL508 Conforms to IEC , CEII VDE 0660 Part 2 Rated thermal current 0A IPR - = Black IPR - 2 = Red IPR - 3 = Green IPR - 4 = Yellow IPR - 5 = Blue IPR - 6 = White Flat Head Pushbutton 28 DIA IPS - = Black IPS - 2 = Red IPS - 3 = Green IPS - 4 = Yellow IPS - 5 = Blue IPS - 6 = White Extended Pushbotton 28 DIA IPFB2 (RED) Emergency Stop Latched, twist to release 35 DIA IPFBC2 (RED) Emergency Stop Latched, key release 35 DIA IPRL - 2 = Red IPRL - 3 = Green IPRL - 4 = Yellow IPRL - 5 = Blue IPRL - 6 = White Illuminated Pushbutton 28 DIA

13 22.5mm PUSHBUTTONS AND SWITCHES IPSL - 2 = Red IPSL - 3 = Green IPSL - 4 = Yellow IPSL - 5 = Blue IPSL - 6 = White Illuminated Extended Pushbutton 28 DIA ISCCD-S ISCCD-W ISCCD-Z Key Operated Selector Switch Key Removable from 0 0 ISCCD-RD-S 0 ISCA-U ISCA-W ISC-Y ISCE-J ISCE-S ISCE-U ISCE-Y ISCE-Z ISCE-W ISCE-X 28 DIA ISCE-RDS ISCE-RDX ISCE-RD-U 0 0 ISCE-RS-S ISCERS-W ISCERS-Z ISCE-RC-S 0 ISNCD Short Handled Selector Switches * ISNCD-RD 28 DIA ISNIA -5.5 ISNE

14 PUSHBUTTONS AND SWITCHES ISNE-RD Key Operated Selector Switch ISNE-RS 28 DIA -5.5 ISNE-RC IS - 2 = Red IS - 3 = Green IS - 4 = Amber IS - 5 = Blue IS - 6 = Clear Signal/Indicator Lamp 29 DIA Contact Blocks COB COB. N/C. N/O Contact Blocks 35 CO2 C20 C 2. N/C 2. N/O. N/C +. N/O BL9SB Lamp Holders Transformers BT0 BT220 BT380 24V.5w Max 24V.5w Max 24V.5w Max BXL- Emergency Stop Box x red, latching mushroom head pushbutton in yellow BX-0 CASE *Long handled and illuminated versions also available part numbers ISNL (Long) ISL (illuminated) 2

15 AMMETER AND VOLTMETER SELECTOR SWITCHES Description Description: Two rotary arm switches for switching of ammeters (4 position) and voltmeters (7 position). Application Suitable for panel builders requiring a panel mounted switch for switching meters between phase currents or line & phase voltages. Dimensions Dimensions (mm) Panel cut-out (mm) 36 Specifications 4.2 Dia x Rated current: BS EN A (AC22) Rated voltage: BS EN V AC IP rating: Front - IP 40, Back - IP 2X Max cable size: 4mm 2 Temperature range: -20ºC to +40ºC CE Marked AU38E AMMETER SELECTOR SWITCH Front plate OFF L L2 R Y L3 B L3 L L3 A 3 V308E VOLTMETER SELECTOR SWITCH Front plate LL2 0 LN L2L3 L2N L L2 L3 N R Y B 0 L3L L3N V 2 3

16 M SERIES MINI CONTACTORS THREE POLE CONTACTORS Current Rating Motors at 45V Contacts Open Type Main Contacts Auxiliary Contacts AC AC3 KW HP Type NO NC NO NC MCOA 30AT MCOA 30AT MCA 30AT MCA 30AT Satisfying the latest international requirements Unique ease of assembly Designed for easy wiring Maximum flexibility Thermal overload relays with extra features Dimensions FOUR POLE CONTACTORS MCOA 400AT MCOA A00AT MCOA B00AT MCA 400AT THERMAL OVERLOAD RELAYS Type Range A Type Range A Type Range A MT03A.-.7 MT03F MT03K MT03B MT03G.-.6 MT03L MT03C MT03H MT03M MT03D MT MT03N MT03E MT03J MT03P 0-4 A MCOA 30AT 77,5 with 2 contact auxiliary block 87.5 with 4 contact auxiliary block ACCESSORIES Front mount aux. 2NO Front mount aux. 2NC Front mount aux. NO + NC Front mount aux. 4NO Front mount aux. 3NO + NC Front Mount aux. 2NO + 2NC Front mount aux. 4NC Side mount aux. NO Side mount aux. NC Mechanical interlock Delay on timer V AC/DC secs. Spare coil Suppressor 2-60V Suppressor V Pole paralleling link Input terminal block for MT03 DIN/screw mounting for MT03 NO auxiliary contact for MT03 Type No. MARN 220 AT MARN 202 AT MARN 2 AT MARN 440 AT MARN 43 AT MARN 422 AT MARN 404 AT MARL 0 AT MARL 0 AT MMHO MREB C0 AC2 MBOA MPOA AE MPOA AE2 MVPOC MVEOT MVBOT MATV0 AT MT03 MARN MMH0 MREBC0AC2 4

17 MAIN CHARACTERISTICS OF NEW CL & CK CONTACTORS RANGE Contactors complied with new international standard IEC-947. This standard is specially tough in contactor tests to ensure even better performance. Great flexibility is achieved thanks to the fact that complete range of contactors uses the same accessories. Three coil terminals. Electronic interface modules, electronic timers and surge suppressors which are connected direct to the coil without cables and which can be used together with front and/or side mounted auxiliary contact blocks. The whole of the new range is also available with DC coils. The overall size of basic contactors is not increased in DC coil versions. The whole range of contactors can be mounted on standard 35mm DIN rail. Double clamp terminals can accommodate simultaneously two different sizes of cable or two different size of cable terminals. Eight auxiliary contacts can be pulled in by the contactor, either by mounting six front blocks (NO or NC) and one side block (2NO or NO + NC) or four side blocks, two each side. Horizontal interlock block : mechanical with electrical contacts (NC + NC). Thermal overload relays, either fitting direct to the contactor or separate mounting on standard 35mm DIN rail. Snap on electronic timers : Delay on, delay off via a contact. Pneumatic timers, front mounting snap on without screws, delay on or delay off. Environmentally friendly raw materials that respect nature in their manufacture and treatment : Contacts are made free of cadmium, all the parts of contactors are free of asbestos, packing is made with recyclable material. Two versions of four pole contactors are supplied 4NO poles (types CL M and CL M) and 2NO + 2NC (types CL05...B00M, CL07...B00M and CL08...B00M) mainly used for two speed motor applications. 5

18 THREE POLE CONTACTORS MAX CURRENT RATING AC AC3 MAX KW RATING AC3 45V/440 CONTACTOR P/No. After P/No. specify coil voltage required and if AC 50Hz or 60Hz. COIL VOLTAGE CL00A30T - 3N/O main contacts + N/O aux. AC CL00D30T - 3N/O main contacts + N/O aux. DC CL0A30T - 3N/O main contacts + N/O aux. AC CL0D30T - 3N/O main contacts + N/O aux. DC CL02A30T - 3N/O main contacts + N/O aux. AC CL02D30T - 3N/O main contacts + N/O aux. DC CL25A30T - 3N/O main contacts + N/O aux. AC CL25D30T - 3N/O main contacts + N/O aux. DC CL03A30M - 3N/O main contacts + N/O aux. AC CL03D30M - 3N/O main contacts + N/O aux. DC CL04A30M - 3N/O main contacts + N/O aux. AC CL04D30M - 3N/O main contacts + N/O aux. DC CL45A300M - 3N/O main contacts only. AC CL45D300M - 3N/O main contacts only. DC CL06A300M - 3N/O main contacts only. AC CL06E300M - 3N/O main contacts only. AC/DC CL07A300M - 3N/O main contacts only. AC CL07E300M - 3N/O main contacts only. AC/DC CL08A300M - 3N/O main contacts only. AC CL08E300M - 3N/O main contacts only. AC/DC CL09A300M - 3N/O main contacts only. AC CL09E300M - 3N/O main contacts only. AC/DC CL0A300M - 3N/O main contacts only. AC CL0E300M - 3N/O main contacts only. AC/DC CK75CA3-3N/O main contacts + N/O & N/C aux. AC CK75CE3-3N/O main contacts + N/O & N/C aux. AC/DC CK08CA3-3N/O main contacts + N/O & N/C aux. AC CK08CE3-3N/O main contacts + N/O & N/C aux. AC/DC CK85BA3-3N/O main contacts + N/O & N/C aux. AC CK85BE3-3N/O main contacts + N/O & N/C aux. AC/DC CK09BE3-3N/O main contacts + N/O & N/C aux. AC/DC CK95BE3-3N/O main contacts + N/O & N/C aux. AC/DC CK0CE3-3N/O main contacts + N/O & N/C aux. AC/DC CKCE3-3N/O main contacts + N/O & N/C aux. AC/DC CK2BE3-3N/O main contacts + N/O & N/C aux. AC/DC CK3BA3-3N/O main contacts + N/O & N/C aux. AC MECHANICAL INTERLOCKS CONTACTOR TYPE INTERLOCK P/No. INTERLOCK WITH 2 AUX CONTACTS For contactors CL00 to CL45 BELA BELA02 For contactors CL05 to CL0 BEL BEL02 For contactors CK75 TO CK2 BEKH N/A For contactor CK3 BEKV N/A 6

19 FOUR POLE CONTACTORS MAX CURRENT RATING AC AC3 MAX KW RATING AC 45V/440 CONTACTOR P/No. COIL VOLTAGE CL0A400T - 4N/O main contacts only. AC CL0D400T - 4N/O main contacts only. DC CL02A400T - 4N/O main contacts only. AC CL02D400T - 4N/O main contacts only. DC CL03A400M - 4N/O main contacts only. AC CL03D400M - 4N/O main contacts only. DC CL04A400M - 4N/O main contacts only. AC CL04D400M - 4N/O main contacts only DC CL05A400M - 4N/O main contacts only. AC CL05E400M - 4N/O main contacts only. DC CL07A400M - 4N/O main contacts only. AC CL07E400M - 4N/O main contacts only. DC CL09A400M - 4N/O main contacts only. AC CL09E400M - 4N/O main contacts only. DC * CK07BA4-4N/O main contacts + N/O & N/C aux. AC * CK07BE4-4N/O main contacts + N/O & N/C aux. AC/DC * CK08BA4-4N/O main contacts + N/O & N/C aux. AC * CK08BE4-4N/O main contacts + N/O & N/C aux. AC/DC * CK09BE4-4N/O main contacts + N/O & N/C aux. AC/DC * CK95BE4-4N/O main contacts + N/O & N/C aux. AC/DC * CK0CE4-4N/O main contacts + N/O & N/C aux. AC/DC * CKCE4-4N/O main contacts + N/O & N/C aux. AC/DC * CK2BE4-4N/O main contacts + N/O & N/C aux. AC/DC * CK3BA4-4N/O main contacts + N/O & N/C aux. AC * CK contactor KW ratings are AC3. After P/No. specify coil voltage required and if AC 50Hz or 60Hz. MECHANICAL INTERLOCKS CONTACTOR TYPE INTERLOCK P/No. INTERLOCK WITH 2 AUX CONTACTS For contactors CL0 to CL04 BELA BELA02 For contactors CL05 to CL09 BEL BEL02 For contactors CK07 TO CK2 BEKH N/A For contactor CK3 BEKV N/A 7

20 THERMAL OVERLOAD RELAYS CLASS 0 FOR CL & CK CONTACTOR TYPES FOR CONTACTORS CL00 TO CL45 P/No. RANGE AMPS RTB RTC RTD RTF RTG -.5 RTH RTJ RTK RTL RTM RTN 8-2 RTP 0-6 RTS RTT RTU 2-26 RTV RTW FOR CONTACTORS CK85 to CK95 P/No. RANGE AMPS RT4N RT4P RT4R FOR CONTACTORS CK0 TO CK2 P/No. RANGE AMPS RT5A RT5B RT5C RT5D RT5E FOR CONTACTORS CL05 TO CL0 P/No. RANGE AMPS RT2A.5-5 RT2B RT2C RT2D RT2E RT2G RT2H RT2J RT2L RT2M 90-0 FOR CONTACTORS CK07 TO CK08 P/No. RANGE AMPS RT3B RT3C TR3D RT3E 0-40 RT3F FOR CONTACTOR CK 3 P/No. RANGE AMPS RT6A FOR SEPARATE DIN RAIL MOUNTING OF RT & RT2 OVERLOADS DIN RAIL ADAPTOR BASES ARE AVAILABLE For overload types RT... use adaptor base RTXP For overload types RT2... use adaptor base RT2XP CONTACTOR ACCESSORIES CL & CK CONTACTORS ADD ON AUXILIARY CONTACT BLOCKS CL PNEUMATIC TIMER AUXILIARY CONTACT BLOCKS Top mounted auxiliary block N/O BCLF0 Top mounted auxiliary block N/C BCLF0 Side mounted auxiliary block 2N/O BCLL20 for building up combinations use BRLL20 Side mounted auxiliaryblock N/O & N/C BCLL for building up combinations use BRLL Delay on N/O & N/C 0. sec to 30 secs Delay on N/O & N/C sec to 60 secs Delay off N/O & N/C 0. sec to 30 secs Delay off N/O & N/C sec to 60 secs SPARE CONTACTOR COILS Available contact office for details. BTLF30C BTLF60C BTFL30D BTLF60D 8

21 CL & CK CONTACTOR Dimensions Three-pole contactors Four-pole contactors 20

22 9 CL & CK CONTACTOR Dimensions

TC Series Contactors Contactors A (AC1) 83 Overload Relays 84 DOL Starters 84 Accessories 85

TC Series Contactors Contactors A (AC1) 83 Overload Relays 84 DOL Starters 84 Accessories 85 2 - Contactors & Overloads CONTACTORS & OVERLOADS 2 Contactor Selection 82 TC Contactors TC Series Contactors Contactors 20-110A (AC1) 83 Overload Relays 84 DOL Starters 84 Accessories 85 Minicontactors

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

362 Umbilo Road, Durban 4001, P.O Box 17211, Congella 4013, Tel: /8, Fax: Website:

362 Umbilo Road, Durban 4001, P.O Box 17211, Congella 4013,   Tel: /8, Fax: Website: CONTACTORS: M SERIES G002 MC1A-310-AT5 230VAC 1NO R 305.00 G002/1 MC1A-310-AT1 24VAC 1NO R 305.00 G002/3 MC1A-310-AT3 110VAC 1NO R 305.00 G002/9 MC1A-310-AT9 48VAC 1NO R 305.00 G002/U MC1A-310-AT12 380VAC

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships wwwkmindustrialcorpcom KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Domae. The right solution for distribution boards

Domae. The right solution for distribution boards Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000 The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical devise cause currents to flow through the wrong path

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

Contactors and Overload Relays

Contactors and Overload Relays Contactors and Overload Relays Catalogue 2011 2 CONTENT Contactor Introduction...4 Range over view...8 Technical information - CN Series...10 Add on accessories - CN Series...12 Accessory fitment over

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

RESIDUAL CURRENT CIRCUIT BREAKER

RESIDUAL CURRENT CIRCUIT BREAKER Quality Features Mid Trip - Different knob position to indicate whether the device is Switched OFF by a fault or Switched OFF manually Inscription Window - Ensures circuit identification and hence reduces

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

MoDPlus Din Distribution Boards

MoDPlus Din Distribution Boards MoDPlus Din Distribution Boards Introduction MoDPlus DIN Distribution Panel Board System MoDPlus Din type Distribution Board System has been designed and developed locally, incorporating features and benefits

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Low voltage switch gear

Low voltage switch gear Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling

More information

Industrial Circuit Protection

Industrial Circuit Protection Industrial Circuit Protection Catalogue 2011 Content Contactor... 2-31 Thermal Overload Relay... 32-45 Capacitor Duty Contactor... 46-51 Motor Protection Circuit Breaker... 52-59 Titania Air Circuit

More information

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short

More information

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Industrial Control Power Transformers

Industrial Control Power Transformers 09/10/15 Class MT Features b Enclosed coils (50-5000); Completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Industrial Control Power Transformers Class MT

Industrial Control Power Transformers Class MT Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Technical data. Miniature Circuit Breakers. System pro M. System pro M Technical data System pro M System pro M 1 Prior to connection of aluminium conductors ensure that their contact points are cleaned, brushed and coated with grease. The contact terminals must be tighten

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Series MTO. Thermal overload relays. Thermal overload relays. for minicontactors from 0.11 to 14A. Standards. General characteristics.

Series MTO. Thermal overload relays. Thermal overload relays. for minicontactors from 0.11 to 14A. Standards. General characteristics. Series MTO for minicontactors from 011 to 14 ontrol circuit up to 690V Power circuit up to 690V Three-pole differential (phase unbalance protection) utomatic ambient temperature compensation between 25º

More information

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi Contents Miniature circuit breakers ic60n miniature circuit breakers 6kA, C curve, 6-63A ic60h miniature circuit breakers 10kA, C curve, 6-63A ic60n miniature circuit breakers 6kA, B curve, 6-63A ic60h

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE. Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

New DX 3 High rating & breaking capacity

New DX 3 High rating & breaking capacity New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand

More information

ADS7 AC Contactor Starters

ADS7 AC Contactor Starters ADS7 AC Contactor Starters ADS7 starters fully comply with BS EN 60947-4-1, IEC 60947-4-1 and VDE 0660. The range offers a multitude of configurations and optional features including a complete choice

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

All round protection guaranteed

All round protection guaranteed s With SLR ll round protection guaranteed Betagard MCB 5SL Inspiring Safety nswers for infrastructure. Overview s a culture Siemens has always endeavoured to introduce innovative products worldwide. The

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

Power systems Protection course

Power systems Protection course Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering Dr.Audih 1 Part 3 Protective Devices Fuses & Circuit Breakers 2 Introduction: Fuse Is advice used

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Motor Circuit Breakers C3

Motor Circuit Breakers C3 Motor Circuit Breakers C3 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes

More information

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6 The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 6 PROTECTIONS 1 FUNCTION OF ELECTRICAL PROTECTION SYSTEMS Problems:

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical) MODULAR DEVICES The range of two, three and four pole isolator switches are of a modular design and fit on DIN 50022 rail. Terminal capacity is 25mm 2. Isolator Switches Rating Poles Modules Reference

More information

Residual Current Circuit-breaker (RCCB) FH 200 Series

Residual Current Circuit-breaker (RCCB) FH 200 Series Residual Current Circuit-breaker (RCCB) FH 200 Series Bi-directional cylindrical terminal ensure higher safety of connecting operations, making them easier. Test pushbutton to verify the correct functioning

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC.

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC. SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC CONTROL UNITS SWITCH DISCONNECTORS & CAM SWITCHES TOP-TECHNIC TOP-TECHNIC EMERGENCY STOP MAIN SWITCHES MAIN SWITCHES TOP-TECHNIC TOP-TECHNIC CAM SWITCHES FOR

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

Datasheet. Electrical Switching / Locking

Datasheet. Electrical Switching / Locking - Standard, Power to Lock,ASi, Un-Monitored and Individual Safety Circuits + Extended Solenoid Controlled Body is used to manage activities by means of a solenoid control element. There are five basic

More information

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications xboard commercial and industrial panelboards xboard effectively combining safety, reliability and performance safety, reliability and performance in commercial and industrial applications NEW xboard (xdb)

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Low Voltage A GE Power Controls Company. General catalogue

Low Voltage A GE Power Controls Company. General catalogue Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

MC FRAME SIZE 1 / UP TO 160A

MC FRAME SIZE 1 / UP TO 160A 8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships wwwkmindustrialcorpcom KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants World Class Power Solutions Rectifiers For Stationary Battery Systems in Nuclear Power Plants General 2 1.1 Application Electronically controlled rectifier assemblies are used in conjunction with suitable

More information

EAD10H80D EAD14H80D EAD17H80D

EAD10H80D EAD14H80D EAD17H80D 12.4 Technical data Consumer units and enclosures dimensions and data RCCB controlled surface mounting consumer units Eaton list Dimensions (mm) number w h d EAD2/3M63 154 223 101 EAD2/3M80 EAD4M63 235

More information